Sample records for iodine computer code

  1. Planar measurement of flow field parameters in a nonreacting supersonic combustor using laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Hartfield, Roy J., Jr.; Hollo, Steven D.; Mcdaniel, James C.

    1990-01-01

    A nonintrusive optical technique, laser-induced iodine fluorescence, has been used to obtain planar measurements of flow field parameters in the supersonic mixing flow field of a nonreacting supersonic combustor. The combustor design used in this work was configured with staged transverse sonic injection behind a rearward-facing step into a Mach 2.07 free stream. A set of spatially resolved measurements of temperature and injectant mole fraction has been generated. These measurements provide an extensive and accurate experimental data set required for the validation of computational fluid dynamic codes developed for the calculation of highly three-dimensional combustor flow fields.

  2. Quantitative measurement of transverse injector and free stream interaction in a nonreacting SCRAMJET combustor using laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Fletcher, D. G.; Mcdaniel, J. C.

    1987-01-01

    A preliminary quantitative study of the compressible flowfield in a steady, nonreacting model SCRAMJET combustor using laser-induced iodine fluorescence (LIIF) is reported. Measurements of density, temperature, and velocity were conducted with the calibrated, nonintrusive, optical technique for two different combustor operating conditions. First, measurements were made in the supersonic flow over a rearward-facing step without transverse injection for comparison with calculated pressure profiles. The second configuration was staged injection behind the rearward-facing step at an injection dynamic pressure ratio of 1.06. These experimental results will be used to validate computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

  3. Modeling of boron species in the Falcon 17 and ISP-34 integral tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazaridis, M.; Capitao, J.A.; Drossinos, Y.

    1996-09-01

    The RAFT computer code for aerosol formation and transport was modified to include boron species in its chemical database. The modification was necessary to calculate fission product transport and deposition in the FAL-17 and ISP-34 Falcon tests, where boric acid was injected. The experimental results suggest that the transport of cesium is modified in the presence of boron. The results obtained with the modified RAFT code are presented; they show good agreement with experimental results for cesium and partial agreement for boron deposition in the Falcon silica tube. The new version of the RAFT code predicts the same behavior formore » iodine deposition as the previous version, where boron species were not included.« less

  4. Stability of iodine in salt fortified with iodine and iron.

    PubMed

    Ranganathan, Srinivasaiyengar; Karmarkar, Madhu G; Krupadanam, Muddepaka; Brahmam, Ginnela N V; Rao, Mendhu Vishnuvardhana; Vijayaraghavan, Kamasamudram; Sivakumar, Bhattriprolu

    2007-03-01

    Determining the stability of iodine in fortified salt can be difficult under certain conditions. Current methods are sometimes unreliable in the presence of iron. To test the new method to more accurately estimate iodine content in double-fortified salt (DFS) fortified with iodine and iron by using orthophosphoric acid instead of sulfuric acid in the titration procedure. A double-blind, placebo-controlled study was carried out on DFS and iodized salt produced by the dry-mixing method. DFS and iodized salt were packed and sealed in color-coded, 0.5-kg, low-density polyethylene pouches, and 25 of these pouches were further packed and sealed in color-coded, double-lined, high-density polyethylene bags and transported by road in closed, light-protected containers to the International Council for the Control of Iodine Deficiency Disorders (ICCIDD), Delhi; the National Institute of Nutrition (NIN), Hyderabad; and the Orissa Unit of the National Nutrition Monitoring Bureau (NNMB), Bhubaneswar. The iodine content of DFS and iodized salt stored under normal room conditions in these places was measured by the modified method every month on the same prescribed dates during the first 6 months and also after 15 months. The iodine content of DFS and iodized salt stored under simulated household conditions was also measured in the first 3 months. After the color code was broken at the end of the study, it was found that the DFS and iodized salt stored at Bhubaneswar, Delhi, and Hyderabad retained more or less the same initial iodine content (30-40 ppm) during the first 6 months, and the stability was not affected after 15 months. The proportion of salt samples having more than 30 ppm iodine was 100% in DFS and iodized salt throughout the study period. Daily opening and closing of salt pouches under simulated household conditions did not result in any iodine loss. The DFS and iodized salt prepared by the dry-mixing method and stored at normal room conditions had excellent iodine stability for more than 1 year.

  5. Experimental investigation of a supersonic swept ramp injector using laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Hartfield, Roy J.; Hollo, Steven D.; Mcdaniel, James C.

    1990-01-01

    Planar measurements of injectant mole fraction and temperature have been conducted in a nonreacting supersonic combustor configured with underexpanded injection in the base of a swept ramp. The temperature measurements were conducted with a Mach 2 test section inlet in streamwise planes perpendicular to the test section wall on which the ramp was mounted. Injection concentration measurements, conducted in cross flow planes with both Mach 2 and Mach 2.9 free stream conditions, dramatically illustrate the domination of the mixing process by streamwise vorticity generated by the ramp. These measurements, conducted using a nonintrusive optical technique (laser-induced iodine fluorescence), provide an accurate and extensive experimental data base for the validation of computation fluid dynamic codes for the calculation of highly three-dimensional supersonic combustor flow fields.

  6. DNA double strand break (DSB) induction and cell survival in iodine-enhanced computed tomography (CT)

    NASA Astrophysics Data System (ADS)

    Streitmatter, Seth W.; Stewart, Robert D.; Jenkins, Peter A.; Jevremovic, Tatjana

    2017-08-01

    A multi-scale Monte Carlo model is proposed to assess the dosimetric and biological impact of iodine-based contrast agents commonly used in computed tomography. As presented, the model integrates the general purpose MCNP6 code system for larger-scale radiation transport and dose assessment with the Monte Carlo damage simulation to determine the sub-cellular characteristics and spatial distribution of initial DNA damage. The repair-misrepair-fixation model is then used to relate DNA double strand break (DSB) induction to reproductive cell death. Comparisons of measured and modeled changes in reproductive cell survival for ultrasoft characteristic k-shell x-rays (0.25-4.55 keV) up to orthovoltage (200-500 kVp) x-rays indicate that the relative biological effectiveness (RBE) for DSB induction is within a few percent of the RBE for cell survival. Because of the very short range of secondary electrons produced by low energy x-ray interactions with contrast agents, the concentration and subcellular distribution of iodine within and near cellular targets have a significant impact on the estimated absorbed dose and number of DSB produced in the cell nucleus. For some plausible models of the cell-level distribution of contrast agent, the model predicts an increase in RBE-weighted dose (RWD) for the endpoint of DSB induction of 1.22-1.40 for a 5-10 mg ml-1 iodine concentration in blood compared to an RWD increase of 1.07  ±  0.19 from a recent clinical trial. The modeled RWD of 2.58  ±  0.03 is also in good agreement with the measured RWD of 2.3  ±  0.5 for an iodine concentration of 50 mg ml-1 relative to no iodine. The good agreement between modeled and measured DSB and cell survival estimates provides some confidence that the presented model can be used to accurately assess biological dose for other concentrations of the same or different contrast agents.

  7. The continuing importance of thyroid scintigraphy in the era of high-resolution ultrasound.

    PubMed

    Meller, J; Becker, W

    2002-08-01

    At the molecular level, the uptake of radioiodine and pertechnetate is proportional to the expression of the thyroidal sodium/iodine symporter (NIS). Qualitative and quantitative scintigraphic evaluation of the thyroid is performed with a gamma camera fitted with an on-line computer system and enables determination of the iodine uptake or the technetium uptake (TCTU) as an iodine clearance equivalent. Despite new molecular genetic insights into congenital hypothyroidism, the iodine-123 or pertechnetate scan remains the most accurate test for the detection of ectopic thyroid tissue. Following the identification of specific mutations of the genes coding for the NIS, thyroid peroxidase and pendrin, the discharge test has lost its role in establishing the diagnosis of inherited dyshormonogenesis, but it is still of value in the assessment of defect severity. In PDS mutations the test can be used to establish the diagnosis of syndromic disease. Quantitative pertechnetate scintigraphy is the most sensitive and specific technique for the diagnosis and quantification of thyroid autonomy. The method has proved to be valuable in risk stratification of spontaneous or iodine-induced hyperthyroidism, in the estimation of the target volume prior to radioiodine therapy and in the evaluation of therapeutic success after definitive treatment. In iodine deficiency areas the thyroid scan remains indispensable for the functional characterisation of a thyroid nodule and is still a first-line diagnostic procedure in cases of suspected thyroid malignancy. This is especially of importance in patients with Graves' disease, among whom a relatively high prevalence of cancer has been found in cold thyroid nodules. While determination of the TCTU is without any value in the differentiation between autoimmune thyroiditis and Graves' disease in most cases, it is of substantial importance in the differentiation between hyperthyroid autoimmune thyroiditis and Graves' disease.

  8. Computation of iodine species concentrations in water

    NASA Technical Reports Server (NTRS)

    Schultz, John R.; Mudgett, Paul D.; Flanagan, David T.; Sauer, Richard L.

    1994-01-01

    During an evaluation of the use of iodine as a water disinfectant and the development of methods for measuring various iodine species in water onboard Space Freedom, it became necessary to compute the concentration of the various species based on equilibrium principles alone. Of particular concern was the case when various amounts of iodine, iodide, strong acid, and strong base are added to water. Such solutions can be used to evaluate the performance of various monitoring methods being considered. The authors of this paper present an overview of aqueous iodine chemistry, a set of nonlinear equations which can be used to model the above case, and a computer program for solving this system of equations using the Newton-Raphson method. The program was validated by comparing results over a range of concentrations and pH values with those previously presented by Gottardi for a given pH. Use of this program indicated that there are multiple roots to many cases and selecting an appropriate initial guess is important. Comparison of program results with laboratory results for the case when only iodine is added to water indicates the program gives high pH values for the iodine concentrations normally used for water disinfection. Extending the model to include the effects of iodate formation results in the computer pH values being closer to those observed, but the model with iodate does not agree well for the case in which base is added in addition to iodine to raise the pH. Potential explanations include failure to obtain equilibrium conditions in the lab, inaccuracies in published values for the equilibrium constants, and inadequate model of iodine chemistry and/or the lack of adequate analytical methods for measuring the various iodine species in water.

  9. Correlation of quantitative dual-energy computed tomography iodine maps and abdominal computed tomography perfusion measurements: are single-acquisition dual-energy computed tomography iodine maps more than a reduced-dose surrogate of conventional computed tomography perfusion?

    PubMed

    Stiller, Wolfram; Skornitzke, Stephan; Fritz, Franziska; Klauss, Miriam; Hansen, Jens; Pahn, Gregor; Grenacher, Lars; Kauczor, Hans-Ulrich

    2015-10-01

    Study objectives were the quantitative evaluation of whether conventional abdominal computed tomography (CT) perfusion measurements mathematically correlate with quantitative single-acquisition dual-energy CT (DECT) iodine concentration maps, the determination of the optimum time of acquisition for achieving maximum correlation, and the estimation of the potential for radiation exposure reduction when replacing conventional CT perfusion by single-acquisition DECT iodine concentration maps. Dual-energy CT perfusion sequences were dynamically acquired over 51 seconds (34 acquisitions every 1.5 seconds) in 24 patients with histologically verified pancreatic carcinoma using dual-source DECT at tube potentials of 80 kVp and 140 kVp. Using software developed in-house, perfusion maps were calculated from 80-kVp image series using the maximum slope model after deformable motion correction. In addition, quantitative iodine maps were calculated for each of the 34 DECT acquisitions per patient. Within a manual segmentation of the pancreas, voxel-by-voxel correlation between the perfusion map and each of the iodine maps was calculated for each patient to determine the optimum time of acquisition topt defined as the acquisition time of the iodine map with the highest correlation coefficient. Subsequently, regions of interest were placed inside the tumor and inside healthy pancreatic tissue, and correlation between mean perfusion values and mean iodine concentrations within these regions of interest at topt was calculated for the patient sample. The mean (SD) topt was 31.7 (5.4) seconds after the start of contrast agent injection. The mean (SD) perfusion values for healthy pancreatic and tumor tissues were 67.8 (26.7) mL per 100 mL/min and 43.7 (32.2) mL per 100 mL/min, respectively. At topt, the mean (SD) iodine concentrations were 2.07 (0.71) mg/mL in healthy pancreatic and 1.69 (0.98) mg/mL in tumor tissue, respectively. Overall, the correlation between perfusion values and iodine concentrations was high (0.77), with correlation of 0.89 in tumor and of 0.56 in healthy pancreatic tissue at topt. Comparing radiation exposure associated with a single DECT acquisition at topt (0.18 mSv) to that of an 80 kVp CT perfusion sequence (2.96 mSv) indicates that an average reduction of Deff by 94% could be achieved by replacing conventional CT perfusion with a single-acquisition DECT iodine concentration map. Quantitative iodine concentration maps obtained with DECT correlate well with conventional abdominal CT perfusion measurements, suggesting that quantitative iodine maps calculated from a single DECT acquisition at an organ-specific and patient-specific optimum time of acquisition might be able to replace conventional abdominal CT perfusion measurements if the time of acquisition is carefully calibrated. This could lead to large reductions of radiation exposure to the patients while offering quantitative perfusion data for diagnosis.

  10. A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction

    PubMed Central

    Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.

    2015-01-01

    Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985

  11. Food Group Intakes as Determinants of Iodine Status among US Adult Population.

    PubMed

    Lee, Kyung Won; Shin, Dayeon; Cho, Mi Sook; Song, Won O

    2016-05-26

    Adequate intake of iodine is essential for proper thyroid function. Although dietary reference intakes for iodine have been established, iodine intake cannot be estimated due to the lack of data on iodine contents in foods. We aimed to determine if food group intakes can predict iodine status assessed by urinary iodine concentration (UIC) from spot urine samples of 5967 US adults in the National Health and Nutrition Examination Survey (NHANES) 2007-2012. From an in-person 24-h dietary recall, all foods consumed were aggregated into 12 main food groups using the individual food code of the US Department of Agriculture (USDA); dairy products, meat/poultry, fish/seaweed, eggs, legumes/nuts/seeds, breads, other grain products, fruits, vegetables, fats/oils, sugars/sweets, and beverages. Chi-square test, Spearman correlation, and multiple linear regression analyses were conducted to investigate the predictability of food group intakes in iodine status assessed by UIC. From the multiple linear regressions, the consumption of dairy products, eggs, and breads, and iodine-containing supplement use were positively associated with UIC, whereas beverage consumption was negatively associated with UIC. Among various food group intakes, dairy product intake was the most important determinant of iodine status in both US men and women. Subpopulation groups with a high risk of iodine deficiency may need nutritional education regarding the consumption of dairy products, eggs, and breads to maintain an adequate iodine status. Efforts toward a better understanding of iodine content in each food and a continued monitoring of iodine status within US adults are both warranted.

  12. Analysis of the influence of the heat transfer phenomena on the late phase of the ThAI Iod-12 test

    NASA Astrophysics Data System (ADS)

    Gonfiotti, B.; Paci, S.

    2014-11-01

    Iodine is one of the major contributors to the source term during a severe accident in a Nuclear Power Plant for its volatility and high radiological consequences. Therefore, large efforts have been made to describe the Iodine behaviour during an accident, especially in the containment system. Due to the lack of experimental data, in the last years many attempts were carried out to fill the gaps on the knowledge of Iodine behaviour. In this framework, two tests (ThAI Iod-11 and Iod-12) were carried out inside a multi-compartment steel vessel. A quite complex transient characterizes these two tests; therefore they are also suitable for thermal- hydraulic benchmarks. The two tests were originally released for a benchmark exercise during the SARNET2 EU Project. At the end of this benchmark a report covering the main findings was issued, stating that the common codes employed in SA studies were able to simulate the tests but with large discrepancies. The present work is then related to the application of the new versions of ASTEC and MELCOR codes with the aim of carry out a new code-to-code comparison vs. ThAI Iod-12 experimental data, focusing on the influence of the heat exchanges with the outer environment, which seems to be one of the most challenging issues to cope with.

  13. Regenerable biocide delivery unit, volume 2

    NASA Technical Reports Server (NTRS)

    Atwater, James E.; Wheeler, Richard R., Jr.

    1992-01-01

    Source code for programs dealing with the following topics are presented: (1) life cycle test stand-parametric test stand control (in BASIC); (2) simultaneous aqueous iodine equilibria-true equilibrium (in C); (3) simultaneous aqueous iodine equilibria-pseudo-equilibrium (in C); (4) pseudo-(fast)-equilibrium with iodide initially present (in C); (5) solution of simultaneous iodine rate expressions (Mathematica); (6) 2nd order kinetics of I2-formic acid in humidity condensate (Mathematica); (7) prototype RMCV onboard microcontroller (CAMBASIC); (8) prototype RAM data dump to PC (in BASIC); and (9) prototype real time data transfer to PC (in BASIC).

  14. [Gemstone computed tomography in the evaluation of material distribution in pulmonary parenchyma for pulmonary embolism].

    PubMed

    Zhang, Lan; Lü, Lei; Wu, Hua-wei; Zhang, Hao; Zhang, Ji-wei

    2011-12-06

    To present our initial experiences with pulmonary high-definition multidetector computed tomography (HDCT) in patients with acute venous thromboembolism (AVTE) to evaluate their corresponding clinical manifestations. Since December 2009 to March 2010, 23 AVTE patients underwent HDCT at our hospital. Pulmonary embolism (PE) was diagnosed based on the 3D-reconstructed images of computed tomography pulmonary angiography (CTPA). The post processed data were collected by spectral imaging system software to detect the iodine distribution maps. Perfusion defects, calculated as the values of iodine content, were compared with those of normal lung parenchymal perfusion in the absence of PE. Among them, 14 AVTE patients were definitely diagnosed with PE. Prior to anticoagulant therapy, their values of iodine content in defective perfusion area were significantly lower than those in normal perfusion area. After a 3-month anticoagulant therapy, the values of iodine content for the defective perfusion area increased significantly (P < 0.05). There was no significant correlation between the values of iodine content for segmental/subsegmental filling defect area and clinical risk score of DVT (r = 2.68, P > 0.05). But there was a significant negative correlation between the values of iodine content for segmental/subsegmental filling defection area and clinical probability score of PE (r = 0.78, P < 0.05). HDCT is a promising modality of visualizing pulmonary microvasculature as a correlative manifestation of regional perfusion. PE results in hypoperfusion with decreased values of iodine content in affected lung parenchyma. Hemodynamic changes in affected areas correlate with the severity of clinical manifestations of PE.

  15. Internal dosimetry through GATE simulations of preclinical radiotherapy using a melanin-targeting ligand

    NASA Astrophysics Data System (ADS)

    Perrot, Y.; Degoul, F.; Auzeloux, P.; Bonnet, M.; Cachin, F.; Chezal, J. M.; Donnarieix, D.; Labarre, P.; Moins, N.; Papon, J.; Rbah-Vidal, L.; Vidal, A.; Miot-Noirault, E.; Maigne, L.

    2014-05-01

    The GATE Monte Carlo simulation platform based on the Geant4 toolkit is under constant improvement for dosimetric calculations. In this study, we explore its use for the dosimetry of the preclinical targeted radiotherapy of melanoma using a new specific melanin-targeting radiotracer labeled with iodine 131. Calculated absorbed fractions and S values for spheres and murine models (digital and CT-scan-based mouse phantoms) are compared between GATE and EGSnrc Monte Carlo codes considering monoenergetic electrons and the detailed energy spectrum of iodine 131. The behavior of Geant4 standard and low energy models is also tested. Following the different authors’ guidelines concerning the parameterization of electron physics models, this study demonstrates an agreement of 1.2% and 1.5% with EGSnrc, respectively, for the calculation of S values for small spheres and mouse phantoms. S values calculated with GATE are then used to compute the dose distribution in organs of interest using the activity distribution in mouse phantoms. This study gives the dosimetric data required for the translation of the new treatment to the clinic.

  16. How Well Does Dual-Energy Computed Tomography With Metal Artifact Reduction Software Improve Image Quality and Quantify Computed Tomography Number and Iodine Concentration?

    PubMed

    Ohira, Shingo; Kanayama, Naoyuki; Wada, Kentaro; Karino, Tsukasa; Nitta, Yuya; Ueda, Yoshihiro; Miyazaki, Masayoshi; Koizumi, Masahiko; Teshima, Teruki

    2018-04-02

    The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS). Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV). The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively. Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.

  17. Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Yu, Quanwen; Yashiro, Toru; Yuasa, Tetsuya; Hasegawa, Yasuo; Itai, Yuji; Akatsuka, Takao

    1999-09-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT system consists of a silicon (111) channel cut monochromator, an x-ray slit and a collimator for fluorescent x ray detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the fluorescent K(alpha) line, incident monochromatic x-ray was set at 37 keV. The FXCT clearly imaged a human thyroid gland and iodine content was estimated quantitatively. In a case of hyperthyroidism, the two-dimensional distribution of iodine content was not uniform, and thyroid cancer had a small amount of iodine. FXCT can be used to detect iodine within thyroid gland quantitatively and to delineate its distribution.

  18. Recent MELCOR and VICTORIA Fission Product Research at the NRC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bixler, N.E.; Cole, R.K.; Gauntt, R.O.

    1999-01-21

    The MELCOR and VICTORIA severe accident analysis codes, which were developed at Sandia National Laboratories for the U. S. Nuclear Regulatory Commission, are designed to estimate fission product releases during nuclear reactor accidents in light water reactors. MELCOR is an integrated plant-assessment code that models the key phenomena in adequate detail for risk-assessment purposes. VICTORIA is a more specialized fission- product code that provides detailed modeling of chemical reactions and aerosol processes under the high-temperature conditions encountered in the reactor coolant system during a severe reactor accident. This paper focuses on recent enhancements and assessments of the two codes inmore » the area of fission product chemistry modeling. Recently, a model for iodine chemistry in aqueous pools in the containment building was incorporated into the MELCOR code. The model calculates dissolution of iodine into the pool and releases of organic and inorganic iodine vapors from the pool into the containment atmosphere. The main purpose of this model is to evaluate the effect of long-term revolatilization of dissolved iodine. Inputs to the model include dose rate in the pool, the amount of chloride-containing polymer, such as Hypalon, and the amount of buffering agents in the containment. Model predictions are compared against the Radioiodine Test Facility (RTF) experiments conduced by Atomic Energy of Canada Limited (AECL), specifically International Standard Problem 41. Improvements to VICTORIA's chemical reactions models were implemented as a result of recommendations from a peer review of VICTORIA that was completed last year. Specifically, an option is now included to model aerosols and deposited fission products as three condensed phases in addition to the original option of a single condensed phase. The three-condensed-phase model results in somewhat higher predicted fission product volatilities than does the single-condensed-phase model. Modeling of U02 thermochemistry was also improved, and results in better prediction of vaporization of uranium from fuel, which can react with released fission products to affect their volatility. This model also improves the prediction of fission product release rates from fuel. Finally, recent comparisons of MELCOR and VICTORIA with International Standard Problem 40 (STORM) data are presented. These comparisons focus on predicted therrnophoretic deposition, which is the dominant deposition mechanism. Sensitivity studies were performed with the codes to examine experimental and modeling uncertainties.« less

  19. Targeted Gold Nanoparticle Contrast Agent for Digital Breast Tomosynthesis and Computed Tomography

    DTIC Science & Technology

    2011-03-01

    injection series was repeated with an iodinated contrast agent, Omnipaque 320 (320 mg I/mL). Iodine enhancement was observed immediately post-injection...shape, size, growth rate, and expression level of cell-surface markers. Today, the most commonly used x-ray contrast agents are iodine-based...structural and radiographic properties of the AuNP. (iii) Evaluate the in vivo effect of the nanoparticles: tumor- enhancement , biodistribution, and

  20. Intravascular enhancement with identical iodine delivery rate using different iodine contrast media in a circulation phantom.

    PubMed

    Mihl, Casper; Wildberger, Joachim E; Jurencak, Tomas; Yanniello, Michael J; Nijssen, Estelle C; Kalafut, John F; Nalbantov, Georgi; Mühlenbruch, Georg; Behrendt, Florian F; Das, Marco

    2013-11-01

    Both iodine delivery rate (IDR) and iodine concentration are decisive factors for vascular enhancement in computed tomographic angiography. It is unclear, however, whether the use of high-iodine concentration contrast media is beneficial to lower iodine concentrations when IDR is kept identical. This study evaluates the effect of using different iodine concentrations on intravascular attenuation in a circulation phantom while maintaining a constant IDR. A circulation phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used (heart rate, 60 beats per minute; stroke volume, 60 mL; blood pressure, 120/80 mm Hg). Maintaining a constant IDR (2.0 g/s) and a constant total iodine load (20 g), prewarmed (37°C) contrast media with differing iodine concentrations (240-400 mg/mL) were injected into the phantom using a double-headed power injector. Serial computed tomographic scans at the level of the ascending aorta (AA), the descending aorta (DA), and the left main coronary artery (LM) were obtained. Total amount of contrast volume (milliliters), iodine delivery (grams of iodine), peak flow rate (milliliter per second), and intravascular pressure (pounds per square inch) were monitored using a dedicated data acquisition program. Attenuation values in the AA, the DA, and the LM were constantly measured (Hounsfield unit [HU]). In addition, time-enhancement curves, aortic peak enhancement, and time to peak were determined. All contrast injection protocols resulted in similar attenuation values: the AA (516 [11] to 531 [37] HU), the DA (514 [17] to 531 [32] HU), and the LM (490 [10] to 507 [17] HU). No significant differences were found between the AA, the DA, and the LM for either peak enhancement (all P > 0.05) or mean time to peak (AA, 19.4 [0.58] to 20.1 [1.05] seconds; DA, 21.1 [1.0] to 21.4 [1.15] seconds; LM, 19.8 [0.58] to 20.1 [1.05] seconds). This phantom study demonstrates that constant injection parameters (IDR, overall iodine load) lead to robust enhancement patterns, regardless of the contrast material used. Higher iodine concentration itself does not lead to higher attenuation levels. These results may stimulate a shift in paradigm toward clinical usage of contrast media with lower iodine concentrations (eg, 240 mg iodine/mL) in individual tailored contrast protocols. The use of low-iodine concentration contrast media is desirable because of the lower viscosity and the resulting lower injection pressure.

  1. The use of iohexol as oral contrast for computed tomography of the abdomen and pelvis.

    PubMed

    Horton, Karen M; Fishman, Elliot K; Gayler, Bob

    2008-01-01

    Positive oral contrast agents (high-osmolar iodinated solutions [high-osmolar contrast medium] or barium sulfate suspensions) are used routinely for abdominal computed tomography. However, these agents are not ideal. Patients complain about the taste and, sometimes, refuse to drink the required quantity. Nausea, vomiting, and diarrhea are frequent. In certain clinical indications, either barium suspensions or high-osmolar contrast mediums may be contraindicated. This technical note describes the potential advantages of using low-osmolar iodinated solutions as an oral contrast agent for computed tomography.

  2. Quantitative Comparison of Virtual Monochromatic Images of Dual Energy Computed Tomography Systems: Beam Hardening Artifact Correction and Variance in Computed Tomography Numbers: A Phantom Study.

    PubMed

    Wu, Rongli; Watanabe, Yoshiyuki; Satoh, Kazuhiko; Liao, Yen-Peng; Takahashi, Hiroto; Tanaka, Hisashi; Tomiyama, Noriyuki

    2018-05-21

    The aim of this study was to quantitatively compare the reduction in beam hardening artifact (BHA) and variance in computed tomography (CT) numbers of virtual monochromatic energy (VME) images obtained with 3 dual-energy computed tomography (DECT) systems at a given radiation dose. Five different iodine concentrations were scanned using dual-energy and single-energy (120 kVp) modes. The BHA and CT number variance were evaluated. For higher iodine concentrations, 40 and 80 mgI/mL, BHA on VME imaging was significantly decreased when the energy was higher than 50 keV (P = 0.003) and 60 keV (P < 0.001) for GE, higher than 80 keV (P < 0.001) and 70 keV (P = 0.002) for Siemens, and higher than 40 keV (P < 0.001) and 60 keV (P < 0.001) for Toshiba, compared with single-energy CT imaging. Virtual monochromatic energy imaging can decrease BHA and improve CT number accuracy in different dual-energy computed tomography systems, depending on energy levels and iodine concentrations.

  3. Iodine concentration calculated by dual-energy computed tomography (DECT) as a functional parameter to evaluate thyroid metabolism in patients with hyperthyroidism.

    PubMed

    Binh, Duong Duc; Nakajima, Takahito; Otake, Hidenori; Higuchi, Tetsuya; Tsushima, Yoshito

    2017-07-19

    Thyroid function in patients with Grave's disease is usually evaluated by thyroid scintigraphy with radioactive iodine. Recently, dual-energy computed tomography (DECT) with two different energy X-rays can calculate iodine concentrations and can be applied for iodine measurements in thyroid glands. This study aimed to assess the potential use of DECT for the functional assessment of the thyroid gland. Thirteen patients with Grave's disease treated at our hospital from May to September 2015 were included in this retrospective study. Before treatments, all subjects had undergone both iodine scintigraphy [three and 24 h after oral administration of 123 I (20 μCi)] and non-enhanced DECT. The region of interests (ROIs) were placed in both lobes of the thyroid glands, and CT values (HU: Hounsfield unit) and iodine concentrations (mg/mL) calculated from DECT images were measured. The correlation between CT values and iodine concentrations from DECT in the thyroid gland was evaluated and then the iodine concentrations were compared with radioactive iodine uptake ratios by thyroid scintigraphy. Mean (±SD) 123 I uptake increased from 46.3 (±22.2) % (range, 11.1-80.1) at 3 h, to 66.5 (±15.2) % (range, 40.0-86.1) at 24 h (p < 0.01). CT values ranged from 34.5 to 98.7 HU [mean: 67.8 (±18.6)], while the iodine concentrations calculated with DECT ranged from 0.0 to 1.3 mg/mL [mean: 0.5 (±0.4)]. A moderate positive correlation between CT values and the calculated iodine concentrations in the thyroid gland was seen (R = 0.429, p < 0.05). A significant negative correlation between 123 I uptake at 3 h and iodine concentration by DECT were seen (R = -0.680, p < 0.05), although no correlation was observed between 123 I uptake at 3 h and CT values (p = 0.087). No correlation was observed between 123 I uptake at 24 h and CT values (p = 0.153) or that between 123 I uptake at 24 h and iodine concentration by DECT (p = 0.073). The negative correlation of 123 I uptake at 3 h with iodine concentration evaluated by DECT was better than that observed with simple CT value. DECT may have a potential role in the evaluation of iodine turnover in hyperthyroid patients.

  4. Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Akiba, Masahiro; Yuasa, Tetsuya; Kazama, Masahiro; Hoshino, Atsunori; Watanabe, Yuuki; Hyodo, Kazuyuki; Dilmanian, F. Avraham; Akatsuka, Takao; Itai, Yuji

    1996-04-01

    We describe a new system of fluorescent x-ray computed tomography applied to image nonradioactive contrast materials in vivo. The system operates on the basis of computed tomography (CT) of the first generation. The experiment was also simulated using the Monte Carlo method. The research was carried out at the BLNE-5A bending-magnet beam line of the Tristan Accumulation Ring in Kek, Japan. An acrylic cylindrical phantom containing five paraxial channels of 5 and 4 mm diameters was imaged. The channels were filled with a diluted iodine-based contrast material, with iodine concentrations of 2 mg/ml and 500 (mu) g/ml. Spectra obtained with the system's high purity germanium (HPGe) detector separated clearly the K(alpha ) and K(beta 1) x-ray fluorescent lines, and the Compton scattering. CT images were reconstructed from projections generated by integrating the counts in these spectral lines. The method had adequate sensitivity and detection power, as shown by the experiment and predicted by the simulations, to show the iodine content of the phantom channels, which corresponded to 1 and 4 (mu) g iodine content per pixel in the reconstructed images.

  5. Current global iodine status and progress over the last decade towards the elimination of iodine deficiency.

    PubMed Central

    Andersson, Maria; Takkouche, Bahi; Egli, Ines; Allen, Henrietta E.; de Benoist, Bruno

    2005-01-01

    OBJECTIVE: To estimate worldwide iodine nutrition and monitor country progress towards sustained elimination of iodine deficiency disorders. METHODS: Cross-sectional data on urinary iodine (UI) and total goitre prevalence (TGP) in school-age children from 1993-2003 compiled in the WHO Global Database on Iodine Deficiency were analysed. The median UI was used to classify countries according to the public health significance of their iodine nutrition status. Estimates of the global and regional populations with insufficient iodine intake were based on the proportion of each country's population with UI below 100 microg/l. TGP was computed for trend analysis over 10 years. FINDINGS: UI data were available for 92.1% of the world's school-age children. Iodine deficiency is still a public health problem in 54 countries. A total of 36.5% (285 million) school-age children were estimated to have an insufficient iodine intake, ranging from 10.1% in the WHO Region of the Americas to 59.9% in the European Region. Extrapolating this prevalence to the general population generated an estimate of nearly two billion individuals with insufficient iodine intake. Iodine intake was more than adequate, or excessive, in 29 countries. Global TGP in the general population was 15.8%. CONCLUSION: Forty-three countries have reached optimal iodine nutrition. Strengthened UI monitoring is required to ensure that salt iodization is having the desired impact, to identify at-risk populations and to ensure sustainable prevention and control of iodine deficiency. Efforts to eliminate iodine deficiency should be maintained and expanded. PMID:16175826

  6. Iodine Incorporation in Calcite: Insights from Computational and Experimental Study

    NASA Astrophysics Data System (ADS)

    Feng, X.; Redfern, S. A. T.

    2016-12-01

    The incorporation of iodine into calcite is important both in the context of radioactive waste disposal (carbonates seem to be the principal host for iodine at the Hnaford site) as well as in paleoproxy methods applied in paleo-oceanography, where iodine content has been proposed as a proxy for fO2. Here, we report on studies of iodine incorporation into calcite carried out by a combination of earlier X-Ray absorption spectroscopy, Raman spectroscopy, X-Ray diffraction and new ab initio DFT calculations (using VASP). Our results show that iodine is principally incorporated into the calcite lattice as IO3, replacing carbon in the carbonate group. The much larger size of iodine, and different outer shell electronic configuration, leads to a distortion of the calcite structure locally. Our DFT results show that the adjacent layers of CO3 groups are significantly distorted, over a length scale of around 0.5 nm, and that this distortion leads to a slight increase in enthalpy associated with the iodine point defect. The relationship to the distorted structure of calcite II is considered, and the role of iodine as an agent of "internal pressure" will be discussed.

  7. X-ray fluorescence camera for imaging of iodine media in vivo.

    PubMed

    Matsukiyo, Hiroshi; Watanabe, Manabu; Sato, Eiichi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Abderyim, Purkhet; Aizawa, Katsuo; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ehara, Shigeru; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2009-01-01

    X-ray fluorescence (XRF) analysis is useful for measuring density distributions of contrast media in vivo. An XRF camera was developed for carrying out mapping for iodine-based contrast media used in medical angiography. Objects are exposed by an X-ray beam from a cerium target. Cerium K-series X-rays are absorbed effectively by iodine media in objects, and iodine fluorescence is produced from the objects. Next, iodine Kalpha fluorescence is selected out by use of a 58-microm-thick stannum filter and is detected by a cadmium telluride (CdTe) detector. The Kalpha rays are discriminated out by a multichannel analyzer, and the number of photons is counted by a counter card. The objects are moved and scanned by an x-y stage in conjunction with a two-stage controller, and X-ray images obtained by iodine mapping are shown on a personal computer monitor. The scan pitch of the x and y axes was 2.5 mm, and the photon counting time per mapping point was 2.0 s. We carried out iodine mapping of non-living animals (phantoms), and iodine Kalpha fluorescence was produced from weakly remaining iodine elements in a rabbit skin cancer.

  8. Low radiation dose in computed tomography: the role of iodine

    PubMed Central

    Aschoff, Andrik J; Catalano, Carlo; Krix, Martin; Albrecht, Thomas

    2017-01-01

    Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration. PMID:28471242

  9. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    PubMed Central

    Jung, Seung Chai; Cho, Jeong Yeon

    2011-01-01

    Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154

  10. Closed-loop wavelength stabilization of an optical parametric oscillator as a front end of a high-power iodine laser chain.

    PubMed

    Kral, L

    2007-05-01

    We present a complex stabilization and control system for a commercially available optical parametric oscillator. The system is able to stabilize the oscillator's output wavelength at a narrow spectral line of atomic iodine with subpicometer precision, allowing utilization of this solid-state parametric oscillator as a front end of a high-power photodissociation laser chain formed by iodine gas amplifiers. In such setup, a precise wavelength matching between the front end and the amplifier chain is necessary due to extremely narrow spectral lines of the gaseous iodine (approximately 20 pm). The system is based on a personal computer, a heated iodine cell, and a few other low-cost components. It automatically identifies the proper peak within the iodine absorption spectrum, and then keeps the oscillator tuned to this peak with high precision and reliability. The use of the solid-state oscillator as the front end allows us to use the whole iodine laser system as a pump laser for the optical parametric chirped pulse amplification, as it enables precise time synchronization with a signal Ti:sapphire laser.

  11. Iodine X-ray fluorescence computed tomography system utilizing a cadmium telluride detector in conjunction with a cerium-target tube

    NASA Astrophysics Data System (ADS)

    Hagiwara, Osahiko; Watanabe, Manabu; Sato, Eiichi; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2011-06-01

    An X-ray fluorescence computed tomography system (XRF-CT) is useful for determining the main atoms in objects. To detect iodine atoms without using a synchrotron, we developed an XRF-CT system utilizing a cadmium telluride (CdTe) detector and a cerium X-ray generator. CT is performed by repeated linear scans and rotations of an object. When cerium K-series characteristic X-rays are absorbed by iodine atoms in objects, iodine K fluorescence is produced from atoms and is detected by the CdTe detector. Next, event signals of X-ray photons are produced with the use of charge-sensitive and shaping amplifiers. Iodine Kα fluorescence is isolated using a multichannel analyzer, and the number of photons is counted using a counter card. In energy-dispersive XRF-CT, the tube voltage and tube current were 70 kV and 0.40 mA, respectively, and the X-ray intensity was 115.3 μGy/s at a distance of 1.0 m from the source. The demonstration of XRF-CT was carried out by the selection of photons in an energy range from 27.5 to 29.5 keV with a photon-energy resolution of 1.2 keV.

  12. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    PubMed

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p < 0.001 for gadolinium maps, single-energy images, and iodine maps, respectively). For infarct versus blood pool, CNR was maximum for iodine maps (CNR 11.8 ± 1.3, 3.8 ± 1.0, and 1.3 ± 0.4, p < 0.001 for iodine maps, gadolinium maps, and single-energy images, respectively). Combined first-pass iodine and late gadolinium maps allowed quantitative separation of blood pool, scar, and remote myocardium. MRI and histology analysis confirmed accurate PCD CT delineation of scar. Simultaneous multi-contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  13. A study on the imaging characteristics of Gold nanoparticles as a contrast agent in X-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Mesbahi, Asghar; Famouri, Fatemeh; Ahar, Mohammad Johari; Ghaffari, Maryam Olade; Ghavami, Seyed Mostafa

    2017-03-01

    Aim: In the current study, some imaging characteristics of AuNPs were quantitatively analyzed and compared with two conventional contrast media (CM) including Iodine and Gadolinium by using of a cylindrical phantom. Methods: AuNPs were synthesized with the mean diameter of 16 nm and were equalized to the concentration of 0.5, 1, 2 and 4 mg/mL in the same volumes. A cylindrical phantom resembling the head and neck was fabricated and drilled to contain small tubes filled with Iodine, Gadolinium, and AuNPs as contrast media. The phantom was scanned in different exposure techniques and CT numbers of three studied contrast media inside test tubes were measured in terms of Hounsfield Unit (HU). The imaging parameters of the noise and contrast to noise ratios (CNR) were calculated for all studied CMs. Results: AuNPs showed 128% and 166% higher CT number in comparison with Iodine and Gadolinium respectively. Also, Iodine had a greater CT number than Gadolinium for the same exposure techniques and concentration. The maximum CT number for AuNPs and studied contrast materials was obtained at the highest mAs and the lowest tube potential. The maximum CT number were 1033±11 (HU) for AuNP, 565±10 (HU) for Iodine, 458±11 for Gadolinium. Moreover, the maximum CNRs of 433±117, 203±53, 145±37 were found for AuNPs, Iodine and Gadolinium respectively. Conclusion: The contrast agent based on AuNPs showed higher imaging quality in terms of contrast and noise relative to other iodine and gadolinium based contrast media in X-ray computed tomography. Application of the AuNPs as a contrast medium in x-ray CT is recommended.

  14. Iodine imaging in thyroid by fluorescent X-ray CT with 0.05 mm spatial resolution

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Yu, Q.; Yashiro, T.; Zeniya, T.; Wu, J.; Hasegawa, Y.; Thet-Thet-Lwin; Hyodo, K.; Yuasa, T.; Dilmanian, F. A.; Akatsuka, T.; Itai, Y.

    2001-07-01

    Fluorescent X-ray computed tomography (FXCT) at a 0.05 mm in-plane spatial resolution and 0.05 mm slice thickness depicted the cross sectional distribution of endogenous iodine within thyroid. The distribution obtained from the FXCT image correlated closely to that obtained from the pathological pictures.

  15. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    PubMed

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  16. Testing Iodine as a New Fuel for Cathodes

    NASA Astrophysics Data System (ADS)

    Glad, Harley; Branam, Richard; Rogers, Jim; Warren, Matthew; Burleson, Connor; Siy, Grace

    2017-11-01

    The objective of this research is to demonstrate the viability of using iodine as an alternative space propulsion propellant. The demonstration requires the testing of a cathode with xenon and then the desired element iodine. Currently, cathodes run on noble gases such as xenon which must be stored in high pressure canisters and is very expensive. These shortcomings have led to researching possible substitutes. Iodine was decided as a suitable candidate because it's cheaper, can be stored as a solid, and has similar mass properties as xenon. In this research, cathodes will be placed in a vacuum chamber and operated on both gases to observe their performance, allowing us to gain a better understanding of iodine's behavior. Several planned projects depend on the knowledge gained from this project, such as larger scaled tests and iodine fed hall thrusters. The tasks of this project included protecting the stainless-steel vacuum chamber by gold plating and Teflon® coating, building a stand to hold the cathode, creating an anode resistant to iodine, and testing the cathode once setup was complete. The successful operation of the cathode was demonstrated. However, the experimental setup proved ineffective at controlling the iodine flow. Current efforts are focused on this problem. REU Site: Fluid Mechanics with Analysis using Computations and Experiments NSF Grant EEC 1659710.

  17. Diffusible iodine-based contrast-enhanced computed tomography (diceCT): an emerging tool for rapid, high-resolution, 3-D imaging of metazoan soft tissues.

    PubMed

    Gignac, Paul M; Kley, Nathan J; Clarke, Julia A; Colbert, Matthew W; Morhardt, Ashley C; Cerio, Donald; Cost, Ian N; Cox, Philip G; Daza, Juan D; Early, Catherine M; Echols, M Scott; Henkelman, R Mark; Herdina, A Nele; Holliday, Casey M; Li, Zhiheng; Mahlow, Kristin; Merchant, Samer; Müller, Johannes; Orsbon, Courtney P; Paluh, Daniel J; Thies, Monte L; Tsai, Henry P; Witmer, Lawrence M

    2016-06-01

    Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward. © 2016 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  18. Gadolinium-enhanced computed tomographic angiography: current status.

    PubMed

    Rosioreanu, Alex; Alberico, Ronald A; Litwin, Alan; Hon, Man; Grossman, Zachary D; Katz, Douglas S

    2005-01-01

    This article reviews the research to date, as well as our clinical experience from two institutions, on gadolinium-enhanced computed tomographic angiography (gCTA) for imaging the body. gCTA may be an appropriate examination for the small percentage of patients who would benefit from noninvasive vascular imaging, but who have contraindications to both iodinated contrast and magnetic resonance imaging. gCTA is more expensive than CTA with iodinated contrast, due to the dose of gadolinium administered, and gCTA has limitations compared with CTA with iodinated contrast, in that parenchymal organs are not optimally enhanced at doses of 0.5 mmol/kg or lower. However, in our experience, gCTA has been a very useful problem-solving examination in carefully selected patients. With the advent of 16-64 detector CT, in combination with bolus tracking, we believe that the overall dose of gadolinium needed for diagnostic CTA examinations, while relatively high, can be safely administered.

  19. Analytical functions for beta and gamma absorbed fractions of iodine-131 in spherical and ellipsoidal volumes.

    PubMed

    Mowlavi, Ali Asghar; Fornasier, Maria Rossa; Mirzaei, Mohammd; Bregant, Paola; de Denaro, Mario

    2014-10-01

    The beta and gamma absorbed fractions in organs and tissues are the important key factors of radionuclide internal dosimetry based on Medical Internal Radiation Dose (MIRD) approach. The aim of this study is to find suitable analytical functions for beta and gamma absorbed fractions in spherical and ellipsoidal volumes with a uniform distribution of iodine-131 radionuclide. MCNPX code has been used to calculate the energy absorption from beta and gamma rays of iodine-131 uniformly distributed inside different ellipsoids and spheres, and then the absorbed fractions have been evaluated. We have found the fit parameters of a suitable analytical function for the beta absorbed fraction, depending on a generalized radius for ellipsoid based on the radius of sphere, and a linear fit function for the gamma absorbed fraction. The analytical functions that we obtained from fitting process in Monte Carlo data can be used for obtaining the absorbed fractions of iodine-131 beta and gamma rays for any volume of the thyroid lobe. Moreover, our results for the spheres are in good agreement with the results of MIRD and other scientific literatures.

  20. Cooperative Light-Activated Iodine and Photoredox Catalysis for the Amination of Csp3 -H Bonds.

    PubMed

    Becker, Peter; Duhamel, Thomas; Stein, Christopher J; Reiher, Markus; Muñiz, Kilian

    2017-06-26

    An unprecedented method that makes use of the cooperative interplay between molecular iodine and photoredox catalysis has been developed for dual light-activated intramolecular benzylic C-H amination. Iodine serves as the catalyst for the formation of a new C-N bond by activating a remote Csp3 -H bond (1,5-HAT process) under visible-light irradiation while the organic photoredox catalyst TPT effects the reoxidation of the molecular iodine catalyst. To explain the compatibility of the two involved photochemical steps, the key N-I bond activation was elucidated by computational methods. The new cooperative catalysis has important implications for the combination of non-metallic main-group catalysis with photocatalysis. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  1. Monte Carlo simulations used to calculate the energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy.

    PubMed

    Hocine, Nora; Meignan, Michel; Masset, Hélène

    2018-04-01

    To better understand the risks of cumulative medical X-ray investigations and the possible causal role of contrast agent on the coronary artery wall, the correlation between iodinated contrast media and the increase of energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy is investigated. The calculations of energy deposition have been performed using Monte Carlo (MC) simulation codes, namely PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and Monte Carlo N-Particle eXtended (MCNPX). Exposure of a cylinder phantom, artery and a metal stent (AISI 316L) to several X-ray photon beams were simulated. For the energies used in cardiac imaging the energy deposited in the coronary artery lumen increases with the quantity of iodine. Monte Carlo calculations indicate a strong dependence of the energy enhancement factor (EEF) on photon energy and iodine concentration. The maximum value of EEF is equal to 25; this factor is showed for 83 keV and for 400 mg Iodine/mL. No significant impact of the stent is observed on the absorbed dose in the artery for incident X-ray beams with mean energies of 44, 48, 52 and 55 keV. A strong correlation was shown between the increase in the concentration of iodine and the energy deposited in the coronary artery lumen for the energies used in cardiac imaging and over the energy range between 44 and 55 keV. The data provided by this study could be useful for creating new medical imaging protocols to obtain better diagnostic information with a lower level of radiation exposure.

  2. Iodine-Catalyzed Isomerization of Dimethyl Muconate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Settle, Amy E.; Berstis, Laura; Zhang, Shuting

    cis,cis-Muconic acid is a platform biobased chemical that can be upgraded to drop-in commodity and novel monomers. Among the possible drop-in products, dimethyl terephthalate can be synthesized via esterification, isomerization, Diels-Alder cycloaddition, and dehydrogenation. The isomerization of cis,cis-dimethyl muconate ( ccDMM) to the trans,trans-form ( ttDMM) can be catalyzed by iodine; however, studies have yet to address (i) the mechanism and reaction barriers unique to DMM, and (ii) the influence of solvent, potential for catalyst recycle, and recovery of high-purity ttDMM. To address this gap, we apply a joint computational and experimental approach to investigate iodine-catalyzed isomerization of DMM. Densitymore » functional theory calculations identified unique regiochemical considerations due to the large number of halogen-diene coordination schemes. Both transition state theory and experiments estimate significant barrier reductions with photodissociated iodine. Solvent selection was critical for rapid kinetics, likely due to solvent complexation with iodine. Under select conditions, ttDMM yields of 95% were achieved in <1 h with methanol, followed by high purity recovery (>98%) with crystallization. Lastly, post-reaction iodine can be recovered and recycled with minimal loss of activity. Altogether, these findings provide new insight into the mechanism and conditions necessary for DMM isomerization with iodine to advance the state-of-the-art for biobased chemicals.« less

  3. Iodine-Catalyzed Isomerization of Dimethyl Muconate

    DOE PAGES

    Settle, Amy E.; Berstis, Laura; Zhang, Shuting; ...

    2018-04-16

    cis,cis-Muconic acid is a platform biobased chemical that can be upgraded to drop-in commodity and novel monomers. Among the possible drop-in products, dimethyl terephthalate can be synthesized via esterification, isomerization, Diels-Alder cycloaddition, and dehydrogenation. The isomerization of cis,cis-dimethyl muconate ( ccDMM) to the trans,trans-form ( ttDMM) can be catalyzed by iodine; however, studies have yet to address (i) the mechanism and reaction barriers unique to DMM, and (ii) the influence of solvent, potential for catalyst recycle, and recovery of high-purity ttDMM. To address this gap, we apply a joint computational and experimental approach to investigate iodine-catalyzed isomerization of DMM. Densitymore » functional theory calculations identified unique regiochemical considerations due to the large number of halogen-diene coordination schemes. Both transition state theory and experiments estimate significant barrier reductions with photodissociated iodine. Solvent selection was critical for rapid kinetics, likely due to solvent complexation with iodine. Under select conditions, ttDMM yields of 95% were achieved in <1 h with methanol, followed by high purity recovery (>98%) with crystallization. Lastly, post-reaction iodine can be recovered and recycled with minimal loss of activity. Altogether, these findings provide new insight into the mechanism and conditions necessary for DMM isomerization with iodine to advance the state-of-the-art for biobased chemicals.« less

  4. Interactions between iodinated contrast media and tissue plasminogen activator: In vitro comparison study.

    PubMed

    Vörös, Eszter; Deres, László; Halmosi, Róbert; Várady, Edit; Tóth, Kálmán; Battyáni, István

    2017-01-01

    Iodinated contrast media (Xenetix®, Ultravist®, Omnipaque®, Visipaque® and Iomeron®) used for computed tomography (CT) may decrease fibrinolysis by recombinant tissue plasminogen activator (rt-PA). We hypothesized that receiving iodinated contrast media before rt-PA may impair thrombolysis as measured by a new model system. Whole blood from Wistar Kyoto rats (n = 10) was obtained and allowed to form blood clots. Thrombolysis was performed by placing individually the prepared clots into 15 mL tubes and adding 5 mL saline buffer, 100μg rt-PA and a different contrast media; adjusting the quantity of iodine to either 30 mg or 60 mg. The thrombolytic efficacy was quantified by measuring the optical density (OD415) of the supernatant at different time points, namely at 0, 30, 60, and 90 min. There was a significant decrease in clot lysis efficiency observed in presence of iodine containing contrast media comparing to positive control group. Moreover, when the quantity of iodine was increased from 30 mg to 60 mg; the dissolution rate downturned with additional ∼50%. In conclusion, our study suggests that high dose of iodine potentially could negatively affect the efficiency of the thrombolytic therapy performed by rt-PA.

  5. Uptake mechanism for iodine species to black carbon.

    PubMed

    Choung, Sungwook; Um, Wooyong; Kim, Minkyung; Kim, Min-Gyu

    2013-09-17

    Natural organic matter (NOM) plays an important role in determining the fate and transport of iodine species such as iodide (I(-)) and iodate (IO3(-)) in groundwater system. Although NOM exists as diverse forms in environments, prior iodine studies have mainly focused on uptake processes of iodide and iodate to humic materials. This study was conducted to determine the iodide and iodate uptake potential for a particulate NOM (i.e., black carbon [BC]). A laboratory-produced BC and commercial humic acid were used for batch experiments to compare their iodine uptake properties. The BC exhibited >100 times greater uptake capability for iodide than iodate at low pH of ~3, while iodide uptake was negligible for the humic acid. The uptake properties of both solids strongly depend on the initial iodine aqueous concentrations. After uptake reaction of iodide to the BC, X-ray absorption fine structure spectroscopy results indicated that the iodide was converted to electrophilic species, and iodine was covalently bound to carbon atom in polycyclic aromatic hydrocarbons present in the BC. The computed distribution coefficients (i.e., Kd values) suggest that the BC materials retard significantly the transport of iodide at low pH in environmental systems containing even a small amount of BC.

  6. First demonstration of iodine mapping in nonliving phantoms using an X-ray fluorescence computed tomography system with a cadmium telluride detector and a tungsten-target tube

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Sato, Yuichi; Ehara, Shigeru; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Nagao, Jiro; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2011-05-01

    X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects, and XRF is emitted by absorbing X-ray photons with energies beyond the K-edge energy of the target atom. Narrow-energy-width bremsstrahlung X-rays are selected using a 3.0-mm-thick aluminum filter. These rays are absorbed by iodine media in objects, and iodine XRF is produced from the iodine atoms. Next, iodine Kα photons are discriminated by a multichannel analyzer and the number of photons is counted by a counter card. CT is performed by repeated linear scans and rotations of an object. The X-ray generator has a 100 μm focus tube with a 0.5-mm-thick beryllium window, and the tube voltage and the current for XRF were 80 kV and 0.50 mA, respectively. The demonstration of XRF-CT for mapping iodine atoms was carried out by selection of photons in an energy range from 27.5 to 29.5 keV with a photon-energy resolution of 1.2 keV.

  7. Contrast medium usage reduction in abdominal computed tomography by using high-iodinated concentration contrast medium

    NASA Astrophysics Data System (ADS)

    Suwannasri, A.; Kaewlai, R.; Asavaphatiboon, S.

    2016-03-01

    This study was to determine if administration of a low volume high-concentration iodinated contrast medium can preserve image quality in comparison with regular-concentration intravenous contrast medium in patient undergoing contrast-enhancement abdominal computed tomography (CT). Eighty-four patients were randomly divided into 3 groups of similar iodine delivery rate; A: 1.2 cc/kg of iomeprol-400, B: 1.0 cc/kg of iomeprol-400 and C: 1.5 cc/kg of ioversol-350. Contrast enhancement of the liver parenchyma, pancreas and aorta was quantitatively measured in Hounsfield units and qualitative assessed by a radiologist. T-test was used to evaluate contrast enhancement, and Chi-square test was used to evaluate qualitative image assessment, at significance level of 0.05 with 95% confidence intervals. There were no statistically significant differences in contrast enhancement of liver parenchyma and pancreas between group A and group C in both quantitative and qualitative analyses. Group C showed superior vascular enhancement to group A and B on quantitative analysis.

  8. Iodine-Catalyzed Isomerization of Dimethyl Muconate.

    PubMed

    Settle, Amy E; Berstis, Laura; Zhang, Shuting; Rorrer, Nicholas A; Hu, Haiming; Richards, Ryan M; Beckham, Gregg T; Crowley, Michael F; Vardon, Derek R

    2018-06-11

    cis,cis-Muconic acid is a platform bio-based chemical that can be upgraded to drop-in commodity and novel monomers. Among the possible drop-in products, dimethyl terephthalate can be synthesized via esterification, isomerization, Diels-Alder cycloaddition, and dehydrogenation. The isomerization of cis,cis-dimethyl muconate (ccDMM) to the trans,trans-form (ttDMM) can be catalyzed by iodine; however, studies have yet to address (i) the mechanism and reaction barriers unique to DMM, and (ii) the influence of solvent, potential for catalyst recycle, and recovery of high-purity ttDMM. To address this gap, we apply a joint computational and experimental approach to investigate iodine-catalyzed isomerization of DMM. Density functional theory calculations identified unique regiochemical considerations owing to the large number of halogen-diene coordination schemes. Both transition state theory and experiments estimate significant barrier reductions with photodissociated iodine. Solvent selection was critical for rapid kinetics, likely because of solvent complexation with iodine. Under select conditions, ttDMM yields of 95 % were achieved in <1 h with methanol, followed by high purity recovery (>98 %) with crystallization. Lastly, post-reaction iodine can be recovered and recycled with minimal loss of activity. Overall, these findings provide new insight into the mechanism and conditions necessary for DMM isomerization with iodine to advance the state-of-the-art for bio-based chemicals. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Simultaneous detection of iodine and iodide on boron doped diamond electrodes.

    PubMed

    Fierro, Stéphane; Comninellis, Christos; Einaga, Yasuaki

    2013-01-15

    Individual and simultaneous electrochemical detection of iodide and iodine has been performed via cyclic voltammetry on boron doped diamond (BDD) electrodes in a 1M NaClO(4) (pH 8) solution, representative of typical environmental water conditions. It is feasible to compute accurate calibration curve for both compounds using cyclic voltammetry measurements by determining the peak current intensities as a function of the concentration. A lower detection limit of about 20 μM was obtained for iodide and 10 μM for iodine. Based on the comparison between the peak current intensities reported during the oxidation of KI, it is probable that iodide (I(-)) is first oxidized in a single step to yield iodine (I(2)). The latter is further oxidized to obtain IO(3)(-). This technique, however, did not allow for a reasonably accurate detection of iodate (IO(3)(-)) on a BDD electrode. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. The Use of Lithium in the Treatment of Thyrotoxicosis

    PubMed Central

    Temple, R.; Berman, M.; Robbins, J.; Wolff, J.

    1972-01-01

    Since lithium has been shown to inhibit release of iodine from the thyroid, we have investigated its therapeutic potential in thyrotoxicosis. Eight detailed 131I kinetic studies were performed on seven thyrotoxic women and data was analyzed using a computer program. Lithium at serum levels of about 1 mEq liter decreased the loss of 131I from the thyroid, led to a fall in serum 131I levels and diminished urinary 131I excretion. Computer simulation of the lithium effect required, in every case, that lithium inhibit hormonal and nonhormonal thyroid iodine release. In five cases a second lithium effect was required for a satisfactory fit of the model soluton with observed data: namely, an inhibition of hormone disappearance from serum. Neither inhibition of release nor of hormone disappearance seemed to be affected by methimazole (release: 52% decrease without methimazole, 60% with methimazole; hormone disappearance: ∼60% decrease in both). When Li+ was discontinued, recovery of the iodine release rate and hormone disappearance rate over the observed time span was variable, ranging from no recovery to rates that exceeded pre-Li+ values. When Li+ is used alone its effect on serum hormone levels is diminished due to continued accumulation of iodide by the thyroid. Thus, serum thyroxine-iodine levels fell 21-30% in 6-8 days in patients who did not receive methimazole and 15-67% in the methimazole-treated subjects. For prolonged therapy, therefore, a thiocarbamide drug must be used in conjunction with Li+. The similarity of inhibition of iodine release from the thyroid produced by Li+ and iodides is discussed. PMID:4115707

  11. High-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction

    PubMed Central

    Shen, Yanguang; Sun, Zhonghua; Xu, Lei; Li, Yu; Zhang, Nan; Yan, Zixu; Fan, Zhanming

    2015-01-01

    Objective To assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR). Methods One hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-triggered Flash protocol. In the low-iodine group, 50 patients received CM containing 270 mg I/mL and were scanned at low tube voltage (100 kVp). In the high-iodine CM group, 50 patients received CM containing 370 mg I/mL and were scanned at the tube voltage (120 kVp). The filtered back projection (FBP) algorithm was used for reconstruction in both groups. In addition, the IR algorithm was used in the low-iodine group. Image quality of the aorta was analyzed subjectively by a 3-point grading scale and objectively by measuring the CT attenuation in terms of the signal- and contrast-to-noise ratios (SNR and CNR, respectively). Radiation and CM doses were compared. Results The CT attenuation, subjective image quality assessment, SNR, and CNR of various aortic regions of interest did not differ significantly between two groups. In the low-iodine group, images reconstructed by FBP and IR demonstrated significant differences in image noise, SNR, and CNR (p<0.05). The low-iodine group resulted in 34.3% less radiation (4.4 ± 0.5 mSv) than the high-iodine group (6.7 ± 0.6 mSv), and 27.3% less iodine weight (20.36 ± 2.65 g) than the high-iodine group (28 ± 1.98 g). Observers exhibited excellent agreement on the aortic image quality scores (κ = 0.904). Conclusions CT images of aorta could be obtained within 2 s by using a DSCT Flash protocol with low tube voltage, IR, and low-iodine-concentration CM. Appropriate contrast enhancement was achieved while maintaining good image quality and decreasing the radiation and iodine doses. PMID:25643353

  12. Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets

    NASA Astrophysics Data System (ADS)

    Leng, Shuai; Zhou, Wei; Yu, Zhicong; Halaweish, Ahmed; Krauss, Bernhard; Schmidt, Bernhard; Yu, Lifeng; Kappler, Steffen; McCollough, Cynthia

    2017-09-01

    Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.

  13. Computer-controlled multi-parameter mapping of 3D compressible flowfields using planar laser-induced iodine fluorescence

    NASA Technical Reports Server (NTRS)

    Donohue, James M.; Victor, Kenneth G.; Mcdaniel, James C., Jr.

    1993-01-01

    A computer-controlled technique, using planar laser-induced iodine fluorescence, for measuring complex compressible flowfields is presented. A new laser permits the use of a planar two-line temperature technique so that all parameters can be measured with the laser operated narrowband. Pressure and temperature measurements in a step flowfield show agreement within 10 percent of a CFD model except in regions close to walls. Deviation of near wall temperature measurements from the model was decreased from 21 percent to 12 percent compared to broadband planar temperature measurements. Computer-control of the experiment has been implemented, except for the frequency tuning of the laser. Image data storage and processing has been improved by integrating a workstation into the experimental setup reducing the data reduction time by a factor of 50.

  14. Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?

    PubMed

    Mulé, Sébastien; Pigneur, Frédéric; Quelever, Ronan; Tenenhaus, Arthur; Baranes, Laurence; Richard, Philippe; Tacher, Vania; Herin, Edouard; Pasquier, Hugo; Ronot, Maxime; Rahmouni, Alain; Vilgrain, Valérie; Luciani, Alain

    2018-05-01

    To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) < 0.05 was considered significant. Mean HCC late-arterial and portal iodine concentrations were 22.7±12.7 mg/mL and 18.7±8.3 mg/mL, respectively. Late-arterial iodine concentration was significantly related to BV (mixed-effects model F statistic (F)=28.52, p<0.0001), arterial BF (aBF, F=17.62, p<0.0001), hepatic perfusion index (F=28.24, p<0.0001), positive enhancement integral (PEI, F=66.75, p<0.0001) and mean slope of increase (F=32.96, p<0.0001), while portal-venous iodine concentration was mainly related to BV (F=29.68, p<0.0001) and PEI (F=66.75, p<0.0001). In advanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.

  15. Material Separation Using Dual-Energy CT: Current and Emerging Applications.

    PubMed

    Patino, Manuel; Prochowski, Andrea; Agrawal, Mukta D; Simeone, Frank J; Gupta, Rajiv; Hahn, Peter F; Sahani, Dushyant V

    2016-01-01

    Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.

  16. Internal dosimetry with the Monte Carlo code GATE: validation using the ICRP/ICRU female reference computational model

    NASA Astrophysics Data System (ADS)

    Villoing, Daphnée; Marcatili, Sara; Garcia, Marie-Paule; Bardiès, Manuel

    2017-03-01

    The purpose of this work was to validate GATE-based clinical scale absorbed dose calculations in nuclear medicine dosimetry. GATE (version 6.2) and MCNPX (version 2.7.a) were used to derive dosimetric parameters (absorbed fractions, specific absorbed fractions and S-values) for the reference female computational model proposed by the International Commission on Radiological Protection in ICRP report 110. Monoenergetic photons and electrons (from 50 keV to 2 MeV) and four isotopes currently used in nuclear medicine (fluorine-18, lutetium-177, iodine-131 and yttrium-90) were investigated. Absorbed fractions, specific absorbed fractions and S-values were generated with GATE and MCNPX for 12 regions of interest in the ICRP 110 female computational model, thereby leading to 144 source/target pair configurations. Relative differences between GATE and MCNPX obtained in specific configurations (self-irradiation or cross-irradiation) are presented. Relative differences in absorbed fractions, specific absorbed fractions or S-values are below 10%, and in most cases less than 5%. Dosimetric results generated with GATE for the 12 volumes of interest are available as supplemental data. GATE can be safely used for radiopharmaceutical dosimetry at the clinical scale. This makes GATE a viable option for Monte Carlo modelling of both imaging and absorbed dose in nuclear medicine.

  17. Simultaneous sentinel lymph node computed tomography and locoregional chemotherapy for lymph node metastasis in rabbit using an iodine-docetaxel emulsion

    PubMed Central

    Kim, Honsoul; Jang, Eun-Ji; Kim, Sang Kyum; Hyung, Woo Jin; Choi, Dong Kyu; Lim, Soo-Jeong; Lim, Joon Seok

    2017-01-01

    Purpose A sentinel lymph node (SLN) tracer can gain multi-functionality by combining it with additional components. We developed a SLN tracer consisting of iodine and docetaxel and applied it as a theragnostic nanoparticle to simultaneously perform SLN computed tomography (CT) lymphography and locoregional chemotherapy of the draining lymphatic system. Results Docetaxel could be loaded in iodine emulsions at a drug-to-surfactant weight ratio as high as that in the drug formulation Taxotere®. The particle size and drug concentration were stable during storage for up to 3 months in optimized nanoemulsions. Popliteal LN enhancement on CT was observed in all healthy rabbits (n=3) and VX2 tumor-implanted rabbits (n=6) 12 hours after injection. The rate of SLN metastasis was significantly lower in the treatment group (29.4%, 5/17) than in the non-treatment group (70.6%, 12/17) (P=0.038). Material and Methods We prepared a nanoemulsion carrying both iodine and docetaxel in a single structure by optimizing the composition of surfactants surrounding the inner iodized oil core. CT was performed 12 hours after subcutaneous injection of the emulsion in healthy rabbits (n=3) and VX2 tumor-implanted rabbits (n=6) for SLN imaging. Next, we tested the effect of treatment by histopathologically assessing the popliteal LN metastasis rate in VX2 tumor-implanted rabbits 7 days after subcutaneous injection of the emulsion (treatment group, n=17) and comparing it with that of non-treatment group rabbits (n=17). Conclusions We developed an iodine-docetaxel emulsion and demonstrated that it can be applied to simultaneously achieve CT SLN imaging and local chemotherapy against nodal metastasis. PMID:28460444

  18. Dual-Energy Micro-Computed Tomography Imaging of Radiation-Induced Vascular Changes in Primary Mouse Sarcomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moding, Everett J.; Clark, Darin P.; Qi, Yi

    2013-04-01

    Purpose: To evaluate the effects of radiation therapy on primary tumor vasculature using dual-energy (DE) micro-computed tomography (micro-CT). Methods and Materials: Primary sarcomas were generated with mutant Kras and p53. Unirradiated tumors were compared with tumors irradiated with 20 Gy. A liposomal-iodinated contrast agent was administered 1 day after treatment, and mice were imaged immediately after injection (day 1) and 3 days later (day 4) with DE micro-CT. CT-derived tumor sizes were used to assess tumor growth. After DE decomposition, iodine maps were used to assess tumor fractional blood volume (FBV) at day 1 and tumor vascular permeability at daymore » 4. For comparison, tumor vascularity and vascular permeability were also evaluated histologically by use of CD31 immunofluorescence and fluorescently-labeled dextrans. Results: Radiation treatment significantly decreased tumor growth from day 1 to day 4 (P<.05). There was a positive correlation between CT measurement of tumor FBV on day 1 and extravasated iodine on day 4 with microvascular density (MVD) on day 4 (R{sup 2}=0.53) and dextran accumulation (R{sup 2}=0.63) on day 4, respectively. Despite no change in MVD measured by histology, tumor FBV significantly increased after irradiation as measured by DE micro-CT (0.070 vs 0.091, P<.05). Both dextran and liposomal-iodine accumulation in tumors increased significantly after irradiation, with dextran fractional area increasing 5.2-fold and liposomal-iodine concentration increasing 4.0-fold. Conclusions: DE micro-CT is an effective tool for noninvasive assessment of vascular changes in primary tumors. Tumor blood volume and vascular permeability increased after a single therapeutic dose of radiation treatment.« less

  19. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    PubMed

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Effectiveness of Adaptive Statistical Iterative Reconstruction for 64-Slice Dual-Energy Computed Tomography Pulmonary Angiography in Patients With a Reduced Iodine Load: Comparison With Standard Computed Tomography Pulmonary Angiography.

    PubMed

    Lee, Ji Won; Lee, Geewon; Lee, Nam Kyung; Moon, Jin Il; Ju, Yun Hye; Suh, Young Ju; Jeong, Yeon Joo

    2016-01-01

    The aim of the study was to assess the effectiveness of the adaptive statistical iterative reconstruction (ASIR) for dual-energy computed tomography pulmonary angiography (DE-CTPA) with a reduced iodine load. One hundred forty patients referred for chest CT were randomly divided into a DE-CTPA group with a reduced iodine load or a standard CTPA group. Quantitative and qualitative image qualities of virtual monochromatic spectral (VMS) images with filtered back projection (VMS-FBP) and those with 50% ASIR (VMS-ASIR) in the DE-CTPA group were compared. Image qualities of VMS-ASIR images in the DE-CTPA group and ASIR images in the standard CTPA group were also compared. All quantitative and qualitative indices, except attenuation value of pulmonary artery in the VMS-ASIR subgroup, were superior to those in the VMS-FBP subgroup (all P < 0.001). Noise and signal-to-noise ratio of VMS-ASIR images were superior to those of ASIR images in the standard CTPA group (P < 0.001 and P = 0.007, respectively). Regarding qualitative indices, noise was significantly lower in VMS-ASIR images of the DE-CTPA group than in ASIR images of the standard CTPA group (P = 0.001). The ASIR technique tends to improve the image quality of VMS imaging. Dual-energy computed tomography pulmonary angiography with ASIR can reduce contrast medium volume and produce images of comparable quality with those of standard CTPA.

  1. 131 iodine gamma dose determination in the thyroid gland using two geometrical shapes: a comparative study

    NASA Astrophysics Data System (ADS)

    Betka, A.; Bentabet, A.; Azbouche, A.; Fenineche, N.; Adjiri, A.; Dib, A.

    2015-05-01

    In order to study the internal gamma dose, we used a Monte Carlo code ‘Penelope’ simulation with two geometrical models (cylindrical and spherical). The deposited energy was determined via the loss of energy calculated from the quantum theory for inelastic collisions based on the first-order (plane-wave) Born approximation for charged particles with individual atoms and molecules. Our results show that the cylindrical geometry is more suitable for carrying out such a study. Moreover, we developed an analytical expression for the 131 iodine gamma dose (the energy deposited per photon absorbed dose). This latter could be considered as an important tool for evaluating the gamma dose without going through stochastic models.

  2. Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography: A Systematic Preclinical Approach.

    PubMed

    Fleischmann, Ulrike; Pietsch, Hubertus; Korporaal, Johannes G; Flohr, Thomas G; Uder, Michael; Jost, Gregor; Lell, Michael M

    2018-05-01

    Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered without compromising vascular enhancement. This opens up new possibilities in CM administration.

  3. Dynamic iterative beam hardening correction (DIBHC) in myocardial perfusion imaging using contrast-enhanced computed tomography.

    PubMed

    Stenner, Philip; Schmidt, Bernhard; Allmendinger, Thomas; Flohr, Thomas; Kachelrie, Marc

    2010-06-01

    In cardiac perfusion examinations with computed tomography (CT) large concentrations of iodine in the ventricle and in the descending aorta cause beam hardening artifacts that can lead to incorrect perfusion parameters. The aim of this study is to reduce these artifacts by performing an iterative correction and by accounting for the 3 materials soft tissue, bone, and iodine. Beam hardening corrections are either implemented as simple precorrections which cannot account for higher order beam hardening effects, or as iterative approaches that are based on segmenting the original image into material distribution images. Conventional segmentation algorithms fail to clearly distinguish between iodine and bone. Our new algorithm, DIBHC, calculates the time-dependent iodine distribution by analyzing the voxel changes of a cardiac perfusion examination (typically N approximately 15 electrocardiogram-correlated scans distributed over a total scan time up to T approximately 30 s). These voxel dynamics are due to changes in contrast agent. This prior information allows to precisely distinguish between bone and iodine and is key to DIBHC where each iteration consists of a multimaterial (soft tissue, bone, iodine) polychromatic forward projection, a raw data comparison and a filtered backprojection. Simulations with a semi-anthropomorphic dynamic phantom and clinical scans using a dual source CT scanner with 2 x 128 slices, a tube voltage of 100 kV, a tube current of 180 mAs, and a rotation time of 0.28 seconds have been carried out. The uncorrected images suffer from beam hardening artifacts that appear as dark bands connecting large concentrations of iodine in the ventricle, aorta, and bony structures. The CT-values of the affected tissue are usually underestimated by roughly 20 HU although deviations of up to 61 HU have been observed. For a quantitative evaluation circular regions of interest have been analyzed. After application of DIBHC the mean values obtained deviate by only 1 HU for the simulations and the corrected values show an increase of up to 61 HU for the measurements. One iteration of DIBHC greatly reduces the beam hardening artifacts induced by the contrast agent dynamics (and those due to bone) now allowing for an improved assessment of contrast agent uptake in the myocardium which is essential for determining myocardial perfusion.

  4. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.

    PubMed

    Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu

    2016-09-01

    Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that the low tube voltage CT protocol is a powerful tool to reduce the radiation dose in CTA, especially with pCTA and cCTA. © 2016 John Wiley & Sons Ltd.

  5. The Iodine Spectrum: A New Look at an Old Topic

    NASA Astrophysics Data System (ADS)

    Long, George; Sauder, Deborah; Shalhoub, George M.; Stout, Roland; Hamby Towns, Marcy; Zielinski, Theresa Julia

    1999-06-01

    This paper describes a new approach to the traditional iodine gas absorption spectrum experiment often performed in undergraduate physical chemistry labs. The approach is student centered and designed to emphasize the conceptual richness in this classic experiment. It gives students the opportunity to examine the conceptual and mathematical connections between spectroscopic data and quantum models by organizing the material in conceptual chunks, which they work through sequentially. Students use symbolic mathematics software, Mathcad, to expedite the sophisticated numerical calculations required. The curricular chunks were specifically constructed to make the sophisticated concepts embedded in the project accessible. The focus activities remind the students of information they already know and require them to employ both paper and pencil and computer worksheets to complete calculations. Five Mathcad templates provide a rich mathematical treatment of the topics in this experiment. This paper describes how the documents MorsePotential.mcd, BirgeSponer.mcd, IodineSpectrum.mcd, FranckCondonBackground.mcd, and FranckCondonComputation.mcd are used during the three weeks in which this experiment can be performed by a typical physical chemistry student. Although originally designed to use the WWW to disseminate information and promote interaction among physical chemistry students at geographically dispersed institutions, this segmented focus-question approach to the iodine experiment has also been used by a physical chemistry class at a single campus. In both formats, faculty noticed decreased anxiety of the students towards the experiment and an increase in the quality of laboratory reports that indicated better understanding of the chemical concepts.

  6. Digital Subtraction Angiography (DSA) Techniques For The Evaluation Of Breast Lesions

    NASA Astrophysics Data System (ADS)

    Flynn, Michael J.; Ackerman, Laurens; Wilderman, Scott; Block, Roger; Watt, Christine; Burke, Matt; Shetty, P. C.

    1984-08-01

    Digital subtraction angiography of the breast may permit the differentiation of benign and malignant breast lesions. We have developed specific techniques for performing DSAB. The patient is examined in an oblique prone position with the involved breast in an immobilization device of our own design. The immobilization device adapts to our angiographic patient table and provides a water bolus with slight compression. The central ray of the x-ray beam is positioned for a lateral view of the breast, similar to the lateral view obtained in a mammogram. Iodinated contrast is injected from a catheter position in the superior vena cava. A kilovoltage of 50 kVp is employed which produces a near optimal signal to noise ratio for iodine contrast. The iodine signal to noise ratio characteristics of breast DSA have been modeled using a computer program which estimates the x-ray spectrum, filtration effects(tube, tissue, iodine, and grid), and image intensifier energy absorption. The energy absorbed in the input phosphor of the image intensifier is determined using a Monte Carlo radiation transport technique. Images are acquired in a 512 x 512 x 10 matrix with a 9" image intensifier using a geometric magnification of approximately 2. Typically, 10 mAs per exposure is required. A maximum of 40 exposures are made in three phases totalling 5 minutes. The average absorbed dose to the breast for a single exposure is 48 millirads (6 cm thickness) as determined by a Monte Carlo radiation transport computation of energy absorbed in breast tissue.

  7. Contrast Materials

    MedlinePlus

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  8. Preliminary application of high-definition computed tomographic Gemstone Spectral Imaging in lung cancer.

    PubMed

    Wang, Guangli; Zhang, Chengqi; Li, Mingying; Deng, Kai; Li, Wei

    2014-01-01

    To evaluate the feasibility of multiparameter quantitative measurement lung cancer by Gemstone Spectral Imaging (GSI) high-definition computed tomography. Seventy-seven patients who were found to have a lung mass or a nodule by CT plain scan for the first time received chest contrast CT scan with GSI mode on high-definition computed tomography. The GSI viewer was used to display the spectral curve, iodine-based images, water-based images, and 101 sets of monochromatic images of a selected region of interest from the relative homogeneous area of the mass or nodule. Iodine concentration, water concentration, spectral curve slope, and CT values at 40 keV of the region of interest were measured. Finally, 68 eligible patients were divided into a pneumonia group (n = 24) and a malignant tumor group (n = 44, including squamous carcinoma, n = 29, and adenocarcinoma, n = 15). Significant differences existed in iodine concentration (t = 6.459), spectral curve slope (t = 6.276), and CT values at 40 keV (t = 6.698) between the pneumonia group and the malignant tumor group (P < 0.05), as well as between squamous carcinoma and adenocarcinoma (t = 6.494, 5.634, 6.091, respectively, P < 0.05), whereas water concentrations were found to have no difference between the 2 groups (t = 0.082, P > 0.05) and between the 2 types of malignant tumors (t = 1.234, P > 0.05). High-definition computed tomographic GSI technique might be helpful to differentiate lung cancer from lung benign lesions by providing qualitative and quantitative information.

  9. Spectral Imaging for Intracranial Stents and Stent Lumen.

    PubMed

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P < .05) and showed the highest mean grading score (2.94 ± 0.94; P < .05) and contrast/noise ratio of in-stent lumen (160.03 ±37.79; P < .05) among all the modes. Iodine (water) images can help reduce stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  10. Sertraline and its iodine product: Experimental and theoretical vibrational studies. Potential in vitro anti-thyroid activity of sertraline and iodine product toxicity with respect to male Wistar rats

    NASA Astrophysics Data System (ADS)

    Escudero, Graciela E.; Ferraresi Curotto, Verónica; Laino, Carlos H.; Pis Diez, Reinaldo; Williams, Patricia A. M.; Ferrer, Evelina G.

    2013-03-01

    Mayor depression, obsessive-compulsive panic, social anxiety disorders are common diseases that are usually treated with sertraline hydrochloride which is the active ingredient of the well known drugs as Zoloft and Lustral. In this work, we presented a more complete vibrational characterization of the solid phase FT-IR spectra of Sertraline hydrochloride and its sertraline-iodine product in which the conformational space of the molecules was investigated performing molecular dynamic simulations within an NVT ensemble. Geometrical, electronic and vibrational properties were calculated with the density functional theory. Comparison of the simulated spectra with the experimental spectra provides important information about the ability of the computational method to describe the vibrational modes of both molecules. In addition, for the first time we present the evaluation of anti-thyroid activity of sertraline hydrochloride by using the Lang's method. Also, with the aim to evaluate the antidepressant effect of its iodine product we demonstrated for this compound the toxic effect towards the male Wistar rats.

  11. Energy discriminating x-ray camera utilizing a cadmium telluride detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Purkhet, Abderyim; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Wantanabe, Manabu; Nagao, Jiro; Nomiya, Seiichiro; Hitomi, Keitaro; Tanaka, Etsuro; Kawai, Toshiaki; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2009-07-01

    An energy-discriminating x-ray camera is useful for performing monochromatic radiography using polychromatic x rays. This x-ray camera was developed to carry out K-edge radiography using iodine-based contrast media. In this camera, objects are exposed by a cone beam from a cerium x-ray generator, and penetrating x-ray photons are detected by a cadmium telluride detector with an amplifier unit. The optimal x-ray photon energy and the energy width are selected out using a multichannel analyzer, and the photon number is counted by a counter card. Radiography was performed by the detector scanning using an x-y stage driven by a two-stage controller, and radiograms obtained by energy discriminating are shown on a personal computer monitor. In radiography, the tube voltage and current were 60 kV and 36 μA, respectively, and the x-ray intensity was 4.7 μGy/s. Cerium K-series characteristic x rays are absorbed effectively by iodine-based contrast media, and iodine K-edge radiography was performed using x rays with energies just beyond iodine K-edge energy 33.2 keV.

  12. Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT.

    PubMed

    Pelgrim, Gert Jan; van Hamersvelt, Robbert W; Willemink, Martin J; Schmidt, Bernhard T; Flohr, Thomas; Schilham, Arnold; Milles, Julien; Oudkerk, Matthijs; Leiner, Tim; Vliegenthart, Rozemarijn

    2017-09-01

    To determine the accuracy of iodine quantification with dual energy computed tomography (DECT) in two high-end CT systems with different spectral imaging techniques. Five tubes with different iodine concentrations (0, 5, 10, 15, 20 mg/ml) were analysed in an anthropomorphic thoracic phantom. Adding two phantom rings simulated increased patient size. For third-generation dual source CT (DSCT), tube voltage combinations of 150Sn and 70, 80, 90, 100 kVp were analysed. For dual layer CT (DLCT), 120 and 140 kVp were used. Scans were repeated three times. Median normalized values and interquartile ranges (IQRs) were calculated for all kVp settings and phantom sizes. Correlation between measured and known iodine concentrations was excellent for both systems (R = 0.999-1.000, p < 0.0001). For DSCT, median measurement errors ranged from -0.5% (IQR -2.0, 2.0%) at 150Sn/70 kVp and -2.3% (IQR -4.0, -0.1%) at 150Sn/80 kVp to -4.0% (IQR -6.0, -2.8%) at 150Sn/90 kVp. For DLCT, median measurement errors ranged from -3.3% (IQR -4.9, -1.5%) at 140 kVp to -4.6% (IQR -6.0, -3.6%) at 120 kVp. Larger phantom sizes increased variability of iodine measurements (p < 0.05). Iodine concentration can be accurately quantified with state-of-the-art DECT systems from two vendors. The lowest absolute errors were found for DSCT using the 150Sn/70 kVp or 150Sn/80 kVp combinations, which was slightly more accurate than 140 kVp in DLCT. • High-end CT scanners allow accurate iodine quantification using different DECT techniques. • Lowest measurement error was found in scans with largest photon energy separation. • Dual-source CT quantified iodine slightly more accurately than dual layer CT.

  13. Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition

    NASA Astrophysics Data System (ADS)

    Yuasa, T.; Akiba, M.; Takeda, T.; Kazama, M.; Hoshino, A.; Watanabe, Y.; Hyodo, K.; Dilmanian, F. A.; Akatsuka, T.; Itai, Y.

    1997-02-01

    We describe a new attenuation correction method for fluorescent X-ray computed tomography (FXCT) applied to image nonradioactive contrast materials in vivo. The principle of the FXCT imaging is that of computed tomography of the first generation. Using monochromatized synchrotron radiation from the BLNE-5A bending-magnet beam line of Tristan Accumulation Ring in KEK, Japan, we studied phantoms with the FXCT method, and we succeeded in delineating a 4-mm-diameter channel filled with a 500 /spl mu/g I/ml iodine solution in a 20-mm-diameter acrylic cylindrical phantom. However, to detect smaller iodine concentrations, attenuation correction is needed. We present a correction method based on the equation representing the measurement process. The discretized equation system is solved by the least-squares method using the singular value decomposition. The attenuation correction method is applied to the projections by the Monte Carlo simulation and the experiment to confirm its effectiveness.

  14. High Atomic Number Contrast Media Offer Potential for Radiation Dose Reduction in Contrast-Enhanced Computed Tomography.

    PubMed

    Roessler, Ann-Christin; Hupfer, Martin; Kolditz, Daniel; Jost, Gregor; Pietsch, Hubertus; Kalender, Willi A

    2016-04-01

    Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.

  15. Clinical determinants of fluorodeoxyglucose positron emission tomography/computed tomography in differentiated thyroid cancer patients with elevated thyroglobulin and negative (131)iodine whole body scans after (131)iodine therapy.

    PubMed

    Shamim, Syed Ejaz; Nang, Lee Boon; Shuaib, Ibrahim Lutfi; Muhamad, Nor Asiah

    2014-05-01

    A cross-sectional prospective study has been conducted on differentiated thyroid cancer (DTC) patients using negative (131)Iodine ((131)I) whole body scans and elevated thyroglobulin (Tg) levels. The main objective of this research was to determine the prevalence of the conversion of differentiated to dedifferentiated thyroid cancer patients during follow up at the Hospital Kuala Lumpur. It has been demonstrated that fluorodeoxyglucose (FDG) uptake is inversely proportional to the iodine concentration and to differentiation of the cells. Thirty-five patients with histologically proven DTC that have undergone total or near total thyroidectomy, and post (131)I radioactive iodine ablation therapy, were selected and prospectively analysed. The patients also had to show at least one negative whole body scan and Tg levels of 10 μg/L and above. The results of the FDG-Positron Emission Tomography/Computed Tomography (PET/CT) were then studied to determine the association and the predictors influencing the outcome by using univariable and multivariable analyses. Out of the thirty-five patients, 60% of them (twenty-one) showed positive results and 40% (fourteen) showed negative. Age, gender, and type of histopathology (HPE) showed significant associations with the positive results of the FDG-PET/CT. The results also showed no correlations observed between the Tg levels and standardised uptake value (SUV)max in the DTC patients with positive disease findings in the FDG-PET/CT. The predictor for this study was age. The prevalence of the conversion of differentiated to dedifferentiated thyroid cancer among patients with negative (131)I and elevated Tg was 60%, with age as the predictor. DTC patients aged 45 year-old and older were seven times more likely to have positive results of FDG-PET/CT imaging.

  16. Dose reduction and image quality optimizations in CT of pediatric and adult patients: phantom studies

    NASA Astrophysics Data System (ADS)

    Jeon, P.-H.; Lee, C.-L.; Kim, D.-H.; Lee, Y.-J.; Jeon, S.-S.; Kim, H.-J.

    2014-03-01

    Multi-detector computed tomography (MDCT) can be used to easily and rapidly perform numerous acquisitions, possibly leading to a marked increase in the radiation dose to individual patients. Technical options dedicated to automatically adjusting the acquisition parameters according to the patient's size are of specific interest in pediatric radiology. A constant tube potential reduction can be achieved for adults and children, while maintaining a constant detector energy fluence. To evaluate radiation dose, the weighted CT dose index (CTDIw) was calculated based on the CT dose index (CTDI) measured using an ion chamber, and image noise and image contrast were measured from a scanned image to evaluate image quality. The dose-weighted contrast-to-noise ratio (CNRD) was calculated from the radiation dose, image noise, and image contrast measured from a scanned image. The noise derivative (ND) is a quality index for dose efficiency. X-ray spectra with tube voltages ranging from 80 to 140 kVp were used to compute the average photon energy. Image contrast and the corresponding contrast-to-noise ratio (CNR) were determined for lesions of soft tissue, muscle, bone, and iodine relative to a uniform water background, as the iodine contrast increases at lower energy (i.e., k-edge of iodine is 33 keV closer to the beam energy) using mixed water-iodine contrast normalization (water 0, iodine 25, 100, 200, and 1000 HU, respectively). The proposed values correspond to high quality images and can be reduced if only high-contrast organs are assessed. The potential benefit of lowering the tube voltage is an improved CNRD, resulting in a lower radiation dose and optimization of image quality. Adjusting the tube potential in abdominal CT would be useful in current pediatric radiography, where the choice of X-ray techniques generally takes into account the size of the patient as well as the need to balance the conflicting requirements of diagnostic image quality and radiation dose optimization.

  17. Clinical Determinants of Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Differentiated Thyroid Cancer Patients with Elevated Thyroglobulin and Negative 131Iodine Whole Body Scans after 131Iodine Therapy

    PubMed Central

    SHAMIM, Syed Ejaz; NANG, Lee Boon; SHUAIB, Ibrahim Lutfi; MUHAMAD, Nor Asiah

    2014-01-01

    Background: A cross-sectional prospective study has been conducted on differentiated thyroid cancer (DTC) patients using negative 131Iodine (131I) whole body scans and elevated thyroglobulin (Tg) levels. The main objective of this research was to determine the prevalence of the conversion of differentiated to dedifferentiated thyroid cancer patients during follow up at the Hospital Kuala Lumpur. It has been demonstrated that fluorodeoxyglucose (FDG) uptake is inversely proportional to the iodine concentration and to differentiation of the cells. Methods: Thirty-five patients with histologically proven DTC that have undergone total or near total thyroidectomy, and post 131I radioactive iodine ablation therapy, were selected and prospectively analysed. The patients also had to show at least one negative whole body scan and Tg levels of 10 μg/L and above. The results of the FDG-Positron Emission Tomography/Computed Tomography (PET/CT) were then studied to determine the association and the predictors influencing the outcome by using univariable and multivariable analyses. Results: Out of the thirty-five patients, 60% of them (twenty-one) showed positive results and 40% (fourteen) showed negative. Age, gender, and type of histopathology (HPE) showed significant associations with the positive results of the FDG-PET/CT. The results also showed no correlations observed between the Tg levels and standardised uptake value (SUV)max in the DTC patients with positive disease findings in the FDG-PET/CT. The predictor for this study was age. Conclusion: The prevalence of the conversion of differentiated to dedifferentiated thyroid cancer among patients with negative 131I and elevated Tg was 60%, with age as the predictor. DTC patients aged 45 year-old and older were seven times more likely to have positive results of FDG-PET/CT imaging. PMID:25246834

  18. Investigation of Li/Nb-sublattices in ion implanted LiNbO3 by RBS and NRA in channelling configuration

    NASA Astrophysics Data System (ADS)

    Schmidt, E.; Ritter, K.; Gärtner, K.; Wendler, E.

    2017-10-01

    Differently oriented LiNbO3 crystals were implanted at room temperature with 1 MeV iodine ions to fluences between 2 × 1013 and 1 × 1014 cm-2, which cover the transition from a low damage level up to complete amorphisation. The aim of this work was to explore the use of nuclear reaction analysis (NRA) in combination with Rutherford backscattering spectrometry (RBS) in channelling configuration for studying the damage evolution as a function of the ion fluence in both the Li and Nb sublattice. Protons with energies between 1.4 and 1.6 MeV and a standard RBS setup were used. Scattering events detected at low energies result from Rutherford backscattering of protons on Nb and O atoms. At high energies alpha particles are registered, which result from the nuclear reaction between protons and Li atoms. Along different low-index crystallographic directions channelling effects within both the RBS and NRA part of the spectra are observed. However, the strength of channeling within the NRA part depends on the crystallographic direction investigated. These effects are explained by the nature of ion-channelling with respect to the small atomic number of Li and is supported by calculations of minimum yields (ratio of scattering yield in aligned and random direction) applying the computer code DICADA. The consequence is that damage studies with NRA can be only performed in Z-direction of LiNbO3. In this case, the Li and Nb sublattice were found to be similarly damaged after 1 MeV iodine implantation.

  19. A computational fluid dynamics simulation of a supersonic chemical oxygen-iodine laser

    NASA Astrophysics Data System (ADS)

    Waichman, K.; Rybalkin, V.; Katz, A.; Dahan, Z.; Barmashenko, B. D.; Rosenwaks, S.

    2007-05-01

    The dissociation of I II molecules at the optical axis of a supersonic chemical oxygen-iodine laser (COIL) was studied via detailed measurements and three dimensional computational fluid dynamics calculations. Comparing the measurements and the calculations enabled critical examination of previously proposed dissociation mechanisms and suggestion of a mechanism consistent with the experimental and theoretical results. The gain, I II dissociation fraction and temperature at the optical axis, calculated using Heidner's model (R.F. Heidner III et al., J. Phys. Chem. 87, 2348 (1983)), are much lower than those measured experimentally. Agreement with the experimental results was reached by using Heidner's model supplemented by Azyazov-Heaven's model (V.N. Azyazov and M.C. Heaven, AIAA J. 44, 1593 (2006)) where I II(A') and vibrationally excited O II(a1Δ) are significant dissociation intermediates.

  20. Substituent Effects on the [N-I-N](+) Halogen Bond.

    PubMed

    Carlsson, Anna-Carin C; Mehmeti, Krenare; Uhrbom, Martin; Karim, Alavi; Bedin, Michele; Puttreddy, Rakesh; Kleinmaier, Roland; Neverov, Alexei A; Nekoueishahraki, Bijan; Gräfenstein, Jürgen; Rissanen, Kari; Erdélyi, Máté

    2016-08-10

    We have investigated the influence of electron density on the three-center [N-I-N](+) halogen bond. A series of [bis(pyridine)iodine](+) and [1,2-bis((pyridine-2-ylethynyl)benzene)iodine](+) BF4(-) complexes substituted with electron withdrawing and donating functionalities in the para-position of their pyridine nitrogen were synthesized and studied by spectroscopic and computational methods. The systematic change of electron density of the pyridine nitrogens upon alteration of the para-substituent (NO2, CF3, H, F, Me, OMe, NMe2) was confirmed by (15)N NMR and by computation of the natural atomic population and the π electron population of the nitrogen atoms. Formation of the [N-I-N](+) halogen bond resulted in >100 ppm (15)N NMR coordination shifts. Substituent effects on the (15)N NMR chemical shift are governed by the π population rather than the total electron population at the nitrogens. Isotopic perturbation of equilibrium NMR studies along with computation on the DFT level indicate that all studied systems possess static, symmetric [N-I-N](+) halogen bonds, independent of their electron density. This was further confirmed by single crystal X-ray diffraction data of 4-substituted [bis(pyridine)iodine](+) complexes. An increased electron density of the halogen bond acceptor stabilizes the [N···I···N](+) bond, whereas electron deficiency reduces the stability of the complexes, as demonstrated by UV-kinetics and computation. In contrast, the N-I bond length is virtually unaffected by changes of the electron density. The understanding of electronic effects on the [N-X-N](+) halogen bond is expected to provide a useful handle for the modulation of the reactivity of [bis(pyridine)halogen](+)-type synthetic reagents.

  1. Substituent Effects on the [N–I–N]+ Halogen Bond

    PubMed Central

    2016-01-01

    We have investigated the influence of electron density on the three-center [N–I–N]+ halogen bond. A series of [bis(pyridine)iodine]+ and [1,2-bis((pyridine-2-ylethynyl)benzene)iodine]+ BF4– complexes substituted with electron withdrawing and donating functionalities in the para-position of their pyridine nitrogen were synthesized and studied by spectroscopic and computational methods. The systematic change of electron density of the pyridine nitrogens upon alteration of the para-substituent (NO2, CF3, H, F, Me, OMe, NMe2) was confirmed by 15N NMR and by computation of the natural atomic population and the π electron population of the nitrogen atoms. Formation of the [N–I–N]+ halogen bond resulted in >100 ppm 15N NMR coordination shifts. Substituent effects on the 15N NMR chemical shift are governed by the π population rather than the total electron population at the nitrogens. Isotopic perturbation of equilibrium NMR studies along with computation on the DFT level indicate that all studied systems possess static, symmetric [N–I–N]+ halogen bonds, independent of their electron density. This was further confirmed by single crystal X-ray diffraction data of 4-substituted [bis(pyridine)iodine]+ complexes. An increased electron density of the halogen bond acceptor stabilizes the [N···I···N]+ bond, whereas electron deficiency reduces the stability of the complexes, as demonstrated by UV-kinetics and computation. In contrast, the N–I bond length is virtually unaffected by changes of the electron density. The understanding of electronic effects on the [N–X–N]+ halogen bond is expected to provide a useful handle for the modulation of the reactivity of [bis(pyridine)halogen]+-type synthetic reagents. PMID:27265247

  2. A Proposed Computed Tomography Contrast Agent Using Carboxybetaine Zwitterionic Tantalum Oxide Nanoparticles: Imaging, Biological, and Physicochemical Performance.

    PubMed

    FitzGerald, Paul F; Butts, Matthew D; Roberts, Jeannette C; Colborn, Robert E; Torres, Andrew S; Lee, Brian D; Yeh, Benjamin M; Bonitatibus, Peter J

    2016-12-01

    The aim of this study was to produce and evaluate a proposed computed tomography (CT) contrast agent based on carboxybetaine zwitterionic (CZ)-coated soluble tantalum oxide (TaO) nanoparticles (NPs). We chose tantalum to provide superior imaging performance compared with current iodine-based clinical CT contrast agents. We developed the CZ coating to provide biological and physical performance similar to that of current iodinated contrast agents. In addition, the aim of this study was to evaluate the imaging, biological, and physicochemical performance of this proposed contrast agent compared with clinically used iodinated agents. We evaluated CT imaging performance of our CZ-TaO NPs compared with that of an iodinated agent in live rats, imaged centrally located within a tissue-equivalent plastic phantom that simulated a large patient. To evaluate vascular contrast enhancement, we scanned the rats' great vessels at high temporal resolution during and after contrast agent injection. We performed several in vivo CZ-TaO NP studies in healthy rats to evaluate tolerability. These studies included injecting the agent at the anticipated clinical dose (ACD) and at 3 times and 6 times the ACD, followed by longitudinal hematology to assess impact to blood cells and organ function (from 4 hours to 1 week). Kidney histological analysis was performed 48 hours after injection at 3 times the ACD. We measured the elimination half-life of CZ-TaO NPs from blood, and we monitored acute kidney injury biomarkers with a kidney injury assay using urine collected from 4 hours to 1 week. We measured tantalum retention in individual organs and in the whole carcass 48 hours after injection at ACD. Carboxybetaine zwitterionic TaO NPs were synthesized and analyzed in detail. We used multidimensional nuclear magnetic resonance to determine surface functionality of the NPs. We measured NP size and solution properties (osmolality and viscosity) of the agent over a range of tantalum concentrations, including the high concentrations required for standard clinical CT imaging. Computed tomography imaging studies demonstrated image contrast improvement of approximately 40% to 50% using CZ-TaO NPs compared with an iodinated agent injected at the same mass concentration. Blood and organ analyses showed no adverse effects after injection in healthy naive rats at 3 times the ACD. Retention of tantalum at 48 hours after injection was less than 2% of the injected dose in the whole carcass, which very closely matched the reported retention of existing commercial iodine-based contrast agents. Urine analysis of sensitive markers for acute kidney injury showed no responses at 1 week after injection at 3 times the ACD; however, a moderate response in the neutrophil gelatinase-associated lipocalin biomarker was measured at 24 and 48 hours. Compared with other TaO NPs reported in the literature, CZ-TaO NPs had relatively low osmolality and viscosity at concentrations greater than 200 mg Ta/mL and were similar in these physical properties to dimeric iodine-based contrast agents. We found that a CZ-TaO NP-based contrast agent is potentially viable for general-purpose clinical CT imaging. Our results suggest that such an agent can be formulated with clinically viable physicochemical properties, can be biologically safe and cleared rapidly in urine, and can provide substantially improved image contrast at CT compared with current iodinated agents.

  3. Radio-guided occult lesion localisation using iodine 125 Seeds “ROLLIS” to guide surgical removal of an impalpable posterior chest wall melanoma metastasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dissanayake, Shashini; Dissanayake, Deepthi; Taylor, Donna B

    Cancer screening and surveillance programmes and the use of sophisticated imaging tools such as positron emission tomography-computed tomography (PET-CT) have increased the detection of impalpable lesions requiring imaging guidance for excision. A new technique involves intra-lesional insertion of a low-activity iodine-125 ({sup 125}I) seed and detection of the radioactive signal in theatre using a hand-held gamma probe to guide surgery. Whilst several studies describe using this method to guide the removal of impalpable breast lesions, only a handful of publications report its use to guide excision of lesions outside the breast. We describe a case in which radio-guided occult lesionmore » localisation using an iodine 125 seed was used to guide excision of an impalpable posterior chest wall metastasis detected on PET-CT.« less

  4. Improved sensitivity of computed tomography towards iodine and gold nanoparticle contrast agents via iterative reconstruction methods

    PubMed Central

    Bernstein, Ally Leigh; Dhanantwari, Amar; Jurcova, Martina; Cheheltani, Rabee; Naha, Pratap Chandra; Ivanc, Thomas; Shefer, Efrat; Cormode, David Peter

    2016-01-01

    Computed tomography is a widely used medical imaging technique that has high spatial and temporal resolution. Its weakness is its low sensitivity towards contrast media. Iterative reconstruction techniques (ITER) have recently become available, which provide reduced image noise compared with traditional filtered back-projection methods (FBP), which may allow the sensitivity of CT to be improved, however this effect has not been studied in detail. We scanned phantoms containing either an iodine contrast agent or gold nanoparticles. We used a range of tube voltages and currents. We performed reconstruction with FBP, ITER and a novel, iterative, modal-based reconstruction (IMR) algorithm. We found that noise decreased in an algorithm dependent manner (FBP > ITER > IMR) for every scan and that no differences were observed in attenuation rates of the agents. The contrast to noise ratio (CNR) of iodine was highest at 80 kV, whilst the CNR for gold was highest at 140 kV. The CNR of IMR images was almost tenfold higher than that of FBP images. Similar trends were found in dual energy images formed using these algorithms. In conclusion, IMR-based reconstruction techniques will allow contrast agents to be detected with greater sensitivity, and may allow lower contrast agent doses to be used. PMID:27185492

  5. Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study

    PubMed Central

    Le, Huy Q.; Molloi, Sabee

    2011-01-01

    Purpose: To experimentally investigate whether a computed tomography (CT) system based on CdZnTe (CZT) detectors in conjunction with a least-squares parameter estimation technique can be used to decompose four different materials. Methods: The material decomposition process was divided into a segmentation task and a quantification task. A least-squares minimization algorithm was used to decompose materials with five measurements of the energy dependent linear attenuation coefficients. A small field-of-view energy discriminating CT system was built. The CT system consisted of an x-ray tube, a rotational stage, and an array of CZT detectors. The CZT array was composed of 64 pixels, each of which is 0.8×0.8×3 mm. Images were acquired at 80 kVp in fluoroscopic mode at 50 ms per frame. The detector resolved the x-ray spectrum into energy bins of 22–32, 33–39, 40–46, 47–56, and 57–80 keV. Four phantoms were constructed from polymethylmethacrylate (PMMA), polyethylene, polyoxymethylene, hydroxyapatite, and iodine. Three phantoms were composed of three materials with embedded hydroxyapatite (50, 150, 250, and 350 mg∕ml) and iodine (4, 8, 12, and 16 mg∕ml) contrast elements. One phantom was composed of four materials with embedded hydroxyapatite (150 and 350 mg∕ml) and iodine (8 and 16 mg∕ml). Calibrations consisted of PMMA phantoms with either hydroxyapatite (100, 200, 300, 400, and 500 mg∕ml) or iodine (5, 15, 25, 35, and 45 mg∕ml) embedded. Filtered backprojection and a ramp filter were used to reconstruct images from each energy bin. Material segmentation and quantification were performed and compared between different phantoms. Results: All phantoms were decomposed accurately, but some voxels in the base material regions were incorrectly identified. Average quantification errors of hydroxyapatite∕iodine were 9.26∕7.13%, 7.73∕5.58%, and 12.93∕8.23% for the three-material PMMA, polyethylene, and polyoxymethylene phantoms, respectively. The average errors for the four-material phantom were 15.62% and 2.76% for hydroxyapatite and iodine, respectively. Conclusions: The calibrated least-squares minimization technique of decomposition performed well in breast imaging tasks with an energy resolving detector. This method can provide material basis images containing concentrations of the relevant materials that can potentially be valuable in the diagnostic process. PMID:21361191

  6. Theoretical study of the gas-phase reactions of iodine atoms ((2)P(3/2)) with H(2), H(2)O, HI, and OH.

    PubMed

    Canneaux, Sébastien; Xerri, Bertrand; Louis, Florent; Cantrel, Laurent

    2010-09-02

    The rate constants of the reactions of iodine atoms with H(2), H(2)O, HI, and OH have been estimated using 39, 21, 13, and 39 different levels of theory, respectively, and have been compared to the available literature values over the temperature range of 250-2500 K. The aim of this methodological work is to demonstrate that standard theoretical methods are adequate to obtain quantitative rate constants for the reactions involving iodine-containing species. Geometry optimizations and vibrational frequency calculations are performed using three methods (MP2, MPW1K, and BHandHLYP) combined with three basis sets (cc-pVTZ, cc-pVQZ, and 6-311G(d,p)). Single-point energy calculations are performed with the highly correlated ab initio coupled cluster method in the space of single, double, and triple (pertubatively) electron excitations CCSD(T) using the cc-pVnZ (n = T, Q, and 5), aug-cc-pVnZ (n = T, Q, and 5), 6-311G(d,p), 6-311+G(3df,2p), and 6-311++G(3df,3pd) basis sets. Canonical transition state theory with a simple Wigner tunneling correction is used to predict the rate constants as a function of temperature. CCSD(T)/cc-pVnZ//MP2/cc-pVTZ (n = T and Q), CCSD(T)/6-311+G(3df,2p)//MP2/6-311G(d,p), and CCSD(T)/6-311++G(3df,3pd)//MP2/6-311G(d,p) levels of theory provide accurate kinetic rate constants when compared to available literature data. The use of the CCSD(T)/cc-pVQZ//MP2/cc-pVTZ and CCSD(T)/6-311++G(3df,3pd) levels of theory allows one to obtain a better agreement with the literature data for all reactions with the exception of the I + H(2) reaction R(1) . This computational procedure has been also used to predict rate constants for some reactions where no available experimental data exist. The use of quantum chemistry tools could be therefore extended to other elements and next applied to develop kinetic networks involving various fission products, steam, and hydrogen in the absence of literature data. The final objective is to implement the kinetics of gaseous reactions in the ASTEC (Accident Source Term Evaluation Code) code to improve speciation of fission transport, which can be transported along the Reactor Coolant System (RCS) of a Pressurized Water Reactor (PWR) in case of a severe accident.

  7. Iodine-induced hyperthyroidism as combination of different etiologies: an overlooked entity in the elderly.

    PubMed

    Foppiani, Luca; Cascio, Christian; Lo Pinto, Giuliano

    2016-10-01

    Iodine-induced thyrotoxicosis, which raises several diagnostic and therapeutical challenges, is often overlooked. Hyperthyroidism can induce atrial fibrillation, a harmful arrhythmia which can precipitate heart failure and cause stroke. We report the case of an elderly man who was diagnosed with tachyfibrillation secondary to hyperthyroidism. Thyroid hyperfunction was subsequently related both to previous amiodarone therapy (probably mixed form) and the recent use of iodinated contrast medium for computed tomography scan. Thyroid ultrasonography showed a plongeant multinodular goitre. After initial worsening, thyroid function improved slowly but progressively on high-dose thyreostatic therapy combined with steroid therapy; tachyfibrillation caused heart failure and a thrombus in the left atrium, and proved initially resistant to combined antiarrhythmic treatments. Progressive reduction in thyroid hormone levels, together with combined cardiologic therapies, controlled the heart rate, though atrial fibrillation persisted; anticoagulant therapy resolved the atrial thrombus. Alterations in thyroid function are common in amiodarone-treated patients, who therefore require regular hormonal checks. The different forms of amiodarone-induced thyrotoxicosis must be investigated, since they require different therapies, though mixed forms often occur. The superimposition of further iodine excess due to other causes may be catastrophic and cause severe cardiac problems in these patients.

  8. Air Density Measurements in a Mach 10 Wake Using Iodine Cordes Bands

    NASA Technical Reports Server (NTRS)

    Balla, Robert J.; Everhart, Joel L.

    2012-01-01

    An exploratory study designed to examine the viability of making air density measurements in a Mach 10 flow using laser-induced fluorescence of the iodine Cordes bands is presented. Experiments are performed in the NASA Langley Research Center 31 in. Mach 10 air wind tunnel in the hypersonic near wake of a multipurpose crew vehicle model. To introduce iodine into the wake, a 0.5% iodine/nitrogen mixture is seeded using a pressure tap at the rear of the model. Air density was measured at 56 points along a 7 mm line and three stagnation pressures of 6.21, 8.62, and 10.0 MPa (900, 1250, and 1450 psi). Average results over time and space show rho(sub wake)/rho(sub freestream) of 0.145 plus or minus 0.010, independent of freestream air density. Average off-body results over time and space agree to better than 7.5% with computed densities from onbody pressure measurements. Densities measured during a single 60 s run at 10.0 MPa are time-dependent and steadily decrease by 15%. This decrease is attributed to model forebody heating by the flow.

  9. Leach test of cladding removal waste grout using Hanford groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Serne, R.J.; Martin, W.J.; Legore, V.L.

    1995-09-01

    This report describes laboratory experiments performed during 1986-1990 designed to produce empirical leach rate data for cladding removal waste (CRW) grout. At the completion of the laboratory work, funding was not available for report completion, and only now during final grout closeout activities is the report published. The leach rates serve as inputs to computer codes used in assessing the potential risk from the migration of waste species from disposed grout. This report discusses chemical analyses conducted on samples of CRW grout, and the results of geochemical computer code calculations that help identify mechanisms involved in the leaching process. Themore » semi-infinite solid diffusion model was selected as the most representative model for describing leaching of grouts. The use of this model with empirically derived leach constants yields conservative predictions of waste release rates, provided no significant changes occur in the grout leach processes over long time periods. The test methods included three types of leach tests--the American Nuclear Society (ANS) 16.1 intermittent solution exchange test, a static leach test, and a once-through flow column test. The synthetic CRW used in the tests was prepared in five batches using simulated liquid waste spiked with several radionuclides: iodine ({sup 125}I), carbon ({sup 14}C), technetium ({sup 99}Tc), cesium ({sup 137}Cs), strontium ({sup 85}Sr), americium ({sup 241}Am), and plutonium ({sup 238}Pu). The grout was formed by mixing the simulated liquid waste with dry blend containing Type I and Type II Portland cement, class F fly ash, Indian Red Pottery clay, and calcium hydroxide. The mixture was allowed to set and cure at room temperature in closed containers for at least 46 days before it was tested.« less

  10. Theoretical investigation on iodine oxides formation and their role in the production of atmospheric aerosols

    NASA Astrophysics Data System (ADS)

    Galvez, Óscar; Gomez, Pedro C.; Gomez-Martin, Juan C.; Saiz-Lopez, Alfonso; Pacios, Luis F.

    2013-04-01

    Atmospheric iodine has received considerable attention in the past two decades due to both its potential role in the catalytic destruction of ozone (1) and its contribution to the formation of ultrafine particles (2). Seaweeds, marine phytoplankton, and abiotic processes release iodocarbons and I2 to the atmosphere, which are photo-oxidized giving iodine oxides that polymerize to finally form iodine oxide particles (IOPs). In the last years, some laboratory studies have been carried out to investigate this process (see e.g. (3)), however the complete mechanism of formation of such particles and the role of water, and other condensable vapors, in this process have not yet been elucidated. In this context, quantum calculations could help to unravel essential steps of these processes and to evaluate relevant physicochemical properties that can be incorporated into atmospheric models. In this contribution, we show results of a theoretical study on different reactions that iodine oxides, in the presence of water, can undergo to form IOPs. Thermodynamic and kinetic properties of these reactions have been obtained at high level ab initio correlated calculations that included relativistic corrections. In these calculations, we have used a relativistic effective potential (REP) and REP-optimized basis sets for iodine atom developed in our group, which have previously been employed in a theoretical study about several iodinated species (4). (1) Saiz-Lopez, A.; Mahajan, A.S.; Salmon, R.A.; Bauguitte, J.B.; Jones, A.E.; Roscoe, H.K.; Plane, J.M.C. Science 2007, 317, 348-351 (2) O'Dowd, C.D.; Jimenez, J.L.; Bahreini, R.; Flagan, R.C.; Seinfeld, J.H.; Hämeri, K.; Pirjola, L.; Kulmala, M.; Jennings, S.G.; Hoffmann, T. Nature, 2002, 417, 632-636. (3) Saunders, R.W.; Kumar, R.; Gómez Martin, J.C.; Mahajan, A.S.; Murray, B.J.; Plane, J.M.C. Z. Phys. Chem. 2010, 224, 1095-1117. (4) Pacios, L.F.; Gálvez, O. J. Chem. Theory Comput., 2010, 6, 1738-1752.

  11. Determination of the spatial resolution required for the HEDR dose code. Hanford Environmental Dose Reconstruction Project: Dose code recovery activities, Calculation 007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napier, B.A.; Simpson, J.C.

    1992-12-01

    A series of scoping calculations has been undertaken to evaluate the doses that may have been received by individuals living in the vicinity of the Hanford site. This scoping calculation (Calculation 007) examined the spatial distribution of potential doses resulting from releases in the year 1945. This study builds on the work initiated in the first scoping calculation, of iodine in cow`s milk; the third scoping calculation, which added additional pathways; the fifth calculation, which addressed the uncertainty of the dose estimates at a point; and the sixth calculation, which extrapolated the doses throughout the atmospheric transport domain. A projectionmore » of dose to representative individuals throughout the proposed HEDR atmospheric transport domain was prepared on the basis of the HEDR source term. Addressed in this calculation were the contributions to iodine-131 thyroid dose of infants from (1) air submersion and groundshine external dose, (2) inhalation, (3) ingestion of soil by humans, (4) ingestion of leafy vegetables, (5) ingestion of other vegetables and fruits, (6) ingestion of meat, (7) ingestion of eggs, and (8) ingestion of cows` milk from-Feeding Regime 1 as described in scoping calculation 001.« less

  12. Hardware in the Loop Testing of an Iodine-Fed Hall Thruster

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A.; Peeples, Steven R.; Cecil, Jim; Lewis, Brandon L.; Molina Fraticelli, Jose C.; Clark, James P.

    2015-01-01

    CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload,1 providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ?Isp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature ( less than100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at -75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe testing performed using an iodine-fed 200 W Hall thruster mounted to a thrust stand and operated in conjunction with MSFCs Small Projects Rapid Integration and Test Environment (SPRITE) Portable Hardware In the Loop (PHIL) hardware. This work is performed in support of the iodine satellite (iSAT) project, which aims to fly a 200-W iodine-fed thruster on a 12-U CubeSat. The SPRITE PHIL hardware allows a given vehicle to do a checkout of its avionics algorithm by allowing it to monitor and feed data to simulated sensors and effectors in a digital environment. These data are then used to determine the attitude of the vehicle and a separate computer is used to interpret the data set and visualize it using a 3D graphical interface. The PHIL hardware allows the testing of the vehicles bus by providing 'real' hardware interfaces (in the case of this test a real RS422 bus) and specific components can be modeled to show their interactions with the avionics algorithm (e.g. a thruster model). For the iSAT project the PHIL is used to visualize the operating cycle of the thruster and the subsequent effect this thrusting has on the attitude of the satellite over a given period of time. The test is controlled using software running on an Andrews Space Cortex 160 flight computer. This computer is the current baseline for a full iSAT mission. While the test could be conducted with a lab computer and software, the team chose to exercise the propulsion system with a representative CubeSat-class computer. For purposes of this test, the "flight" software monitored the propulsion and PPU systems, controlled operation of the thruster, and provided thruster state data to the PHIL simulation. Commands to operate the thruster were initiated from an operator's workstation outside the vacuum chamber and passed through the Cortex 160 to exercise portions of the flight avionics. Two custom-designed pieces of electronics hardware have been designed to operate the propellant feed system. One piece of hardware is an auxiliary board that controls a latch valve, proportional flow control valves (PFCVs) and valve heaters as well as measuring pressures, temperatures and PFCV feedback voltage. An onboard FPGA provides a serial link for issuing commands and manages all lower level input-output functions. The other piece of hardware is a power distribution board, which accepts a standard bus voltage input and converts this voltage into all the different current-voltage types required to operate the auxiliary board. These electronics boards are located in the vacuum chamber near the thruster, exposing this hardware to both the vacuum and plasma environments they would encounter during a mission, with these components communicating to the flight computer through an RS-422 interface. The auxiliary board FPGA provides a 28V MOSFET switch circuit with a 20ms pulse to open or close the iodine propellant feed system latch valve. The FPGA provides a pulse width modulation (PWM) signal to a DC/DC boost converter to produce the 12-120V needed for control of the proportional flow control valve. There are eight MOSFET-switched heating circuits in the system. Heaters are 28V and located in the latch valve, PFCV, propellant tank and propellant feed lines. Both the latch valve and PFCV have thermistors built into them for temperature monitoring. There are also seven resistance temperature device (RTD) circuits on the auxiliary board that can be used to measure the propellant tank and feedline temperatures. The signals are conditioned and sent to an analog to digital converter (ADC), which is directly commanded and controlled by the FPGA.

  13. Taxanes as a risk factor for acute adverse reactions to iodinated contrast media in cancer patients.

    PubMed

    Farolfi, Alberto; Della Luna, Corradina; Ragazzini, Angela; Carretta, Elisa; Gentili, Nicola; Casadei, Carla; Aquilina, Michele; Barone, Domenico; Minguzzi, Martina; Amadori, Dino; Nanni, Oriana; Gavelli, Giampaolo

    2014-08-01

    The impact of cytotoxic agents on the risk of acute allergy-like adverse reactions (ARs) to intravenous iodinated contrast media (ICM) injections is unknown. We retrospectively reviewed 13,565 computed tomography (CT) scans performed in a consecutive cohort of cancer patients from January 1, 2010 to December 31, 2012. Episodes of acute ICM-related ARs were reported to the pharmacovigilance officer. The following matched comparisons were made: tax code, gender, primary tumor, antineoplastic therapy, and date of last cycle. Concomitant antineoplastic treatment was classified into five groups: platinum, taxane, platinum plus taxane, other, and no treatment group (no therapy had been administered in the previous 24 months). Logistic regression was used to estimate odds ratio (OR) and 95% confidence interval (CI) to evaluate the risk of acute ICM-related ARs. Of 10,472 contrast-enhanced CT scans, 97 (0.93%; 95% CI: 0.74-1.11) ICM-related ARs were reported, 11 of which (0.1%) were severe, including one fatality. The overall incidence was significantly higher in patients aged <65 years (p = .0062) and in the platinum plus taxane and taxane groups (p = .007), whereas no correlation was found with gender, number of previous CT scans, site of disease, or treatment setting. Multivariate analysis confirmed an increased risk for patients aged <65 years (OR: 1.73; 95% CI: 1.14-2.63) and for the taxane group (in comparison with the no treatment group; OR: 2.06; 95% CI: 1.02-4.16). Among cancer patients, concomitant treatment with taxanes and younger age would seem to be risk factors for ICM-related ARs. ©AlphaMed Press.

  14. Taxanes as a Risk Factor for Acute Adverse Reactions to Iodinated Contrast Media in Cancer Patients

    PubMed Central

    Farolfi, Alberto; Della Luna, Corradina; Ragazzini, Angela; Carretta, Elisa; Gentili, Nicola; Casadei, Carla; Aquilina, Michele; Barone, Domenico; Minguzzi, Martina; Amadori, Dino; Nanni, Oriana

    2014-01-01

    Background. The impact of cytotoxic agents on the risk of acute allergy-like adverse reactions (ARs) to intravenous iodinated contrast media (ICM) injections is unknown. Methods. We retrospectively reviewed 13,565 computed tomography (CT) scans performed in a consecutive cohort of cancer patients from January 1, 2010 to December 31, 2012. Episodes of acute ICM-related ARs were reported to the pharmacovigilance officer. The following matched comparisons were made: tax code, gender, primary tumor, antineoplastic therapy, and date of last cycle. Concomitant antineoplastic treatment was classified into five groups: platinum, taxane, platinum plus taxane, other, and no treatment group (no therapy had been administered in the previous 24 months). Logistic regression was used to estimate odds ratio (OR) and 95% confidence interval (CI) to evaluate the risk of acute ICM-related ARs. Results. Of 10,472 contrast-enhanced CT scans, 97 (0.93%; 95% CI: 0.74–1.11) ICM-related ARs were reported, 11 of which (0.1%) were severe, including one fatality. The overall incidence was significantly higher in patients aged <65 years (p = .0062) and in the platinum plus taxane and taxane groups (p = .007), whereas no correlation was found with gender, number of previous CT scans, site of disease, or treatment setting. Multivariate analysis confirmed an increased risk for patients aged <65 years (OR: 1.73; 95% CI: 1.14–2.63) and for the taxane group (in comparison with the no treatment group; OR: 2.06; 95% CI: 1.02–4.16). Conclusion. Among cancer patients, concomitant treatment with taxanes and younger age would seem to be risk factors for ICM-related ARs. PMID:25063226

  15. The EDIT-COMGEOM Code

    DTIC Science & Technology

    1975-09-01

    This report assumes a familiarity with the GIFT and MAGIC computer codes. The EDIT-COMGEOM code is a FORTRAN computer code. The EDIT-COMGEOM code...converts the target description data which was used in the MAGIC computer code to the target description data which can be used in the GIFT computer code

  16. Temporal and spectral imaging with micro-CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Samuel M.; Johnson, G. Allan; Badea, Cristian T.

    2012-08-15

    Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separatemore » volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.« less

  17. Correction of energy-dependent systematic errors in dual-energy X-ray CT using a basis material coefficients transformation method

    NASA Astrophysics Data System (ADS)

    Goh, K. L.; Liew, S. C.; Hasegawa, B. H.

    1997-12-01

    Computer simulation results from our previous studies showed that energy dependent systematic errors exist in the values of attenuation coefficient synthesized using the basis material decomposition technique with acrylic and aluminum as the basis materials, especially when a high atomic number element (e.g., iodine from radiographic contrast media) was present in the body. The errors were reduced when a basis set was chosen from materials mimicking those found in the phantom. In the present study, we employed a basis material coefficients transformation method to correct for the energy-dependent systematic errors. In this method, the basis material coefficients were first reconstructed using the conventional basis materials (acrylic and aluminum) as the calibration basis set. The coefficients were then numerically transformed to those for a more desirable set materials. The transformation was done at the energies of the low and high energy windows of the X-ray spectrum. With this correction method using acrylic and an iodine-water mixture as our desired basis set, computer simulation results showed that accuracy of better than 2% could be achieved even when iodine was present in the body at a concentration as high as 10% by mass. Simulation work had also been carried out on a more inhomogeneous 2D thorax phantom of the 3D MCAT phantom. The results of the accuracy of quantitation were presented here.

  18. Iodine Coulometry of Various Reducing Agents Including Thiols with Online Photocell Detection Coupled to a Multifunctional Chemical Analysis Station to Eliminate Student End Point Detection by Eye

    ERIC Educational Resources Information Center

    Padilla Mercado, Jeralyne B.; Coombs, Eri M.; De Jesus, Jenny P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2018-01-01

    Multifunctional chemical analysis (MCA) systems provide a viable alternative for large scale instruction while supporting a hands-on approach to more advanced instrumentation. These systems are robust and typically use student stations connected to a remote central computer for data collection, minimizing the need for computers at every student…

  19. Regional Distribution of Pulmonary Blood Volume with Dual-Energy Computed Tomography: Results in 42 Subjects.

    PubMed

    Felloni, Paul; Duhamel, Alain; Faivre, Jean-Baptiste; Giordano, Jessica; Khung, Suonita; Deken, Valérie; Remy, Jacques; Remy-Jardin, Martine

    2017-11-01

    The noninvasive approach of lung perfusion generated from dual-energy computed tomography acquisitions has entered clinical practice. The purpose of this study was to analyze the regional distribution of iodine within distal portions of the pulmonary arterial bed on dual-source, dual-energy computed tomography examinations in a cohort of subjects without cardiopulmonary pathologies. The study population included 42 patients without cardiorespiratory disease, enabling quantitative and qualitative analysis of pulmonary blood volume after administration of a 40% contrast agent. Qualitative analysis was based on visual assessment. Quantitative analysis was obtained after semiautomatic division of each lung into 18 areas. The iodine concentration did not significantly differ between the right (R) and left (L) lungs (P = .49), with a mean attenuation of 41.35 Hounsfield units (HU) and 41.14 HU, respectively. Three regional gradients of attenuation were observed between: (a) lung bases and apices (P < .001), linked to the conditions of examination (mean Δ: 6.23 in the R lung; 5.96 in the L lung); (b) posterior and anterior parts of the lung (P < .001) due to gravity (mean Δ: 11.92 in the R lung ; 15.93 in the L lung); and (c) medullary and cortical lung zones (P < .001) (mean Δ: 9.35 in the R lung ; 8.37 in the L lung). The intensity of dependent-nondependent (r = 0.42; P < .001) and corticomedullary (r = 0.58; P < .0001) gradients was correlated to the overall iodine concentration. Distribution of pulmonary blood volume is influenced by physiological gradients and scanning conditions. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  20. Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com; Ierardi, Anna Maria; Radaelli, Alessandro

    AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrastmore » utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.« less

  1. Experimentally determined spectral optimization for dedicated breast computed tomography.

    PubMed

    Prionas, Nicolas D; Huang, Shih-Ying; Boone, John M

    2011-02-01

    The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material/thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT technique factors. A cadaveric breast specimen was acquired under appropriate approval and scanned using a prototype bCT scanner. Inserted into the specimen were cylindrical inserts of polyethylene, water, iodine contrast medium (iodixanol, 2.5 mg/ml), and calcium hydroxyapatite (100 mg/ml). Six x-ray tube potentials (50, 60, 70, 80, 90, and 100 kVp) and three different filters (0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn) were tested. For each set of technique factors, the intensity (linear attenuation coefficient) and noise were measured within six regions of interest (ROIs): Glandular tissue, adipose tissue, polyethylene, water, iodine contrast medium, and calcium hydroxyapatite. Dose-normalized contrast to noise ratio (CNRD) was measured for pairwise comparisons among the six ROIs. Regression models were used to estimate the effect of tube potential and added filtration on intensity, noise, and CNRD. Iodine contrast enhancement was maximized using 60 kVp and 0.2 mm Cu. Microcalcification contrast and soft-tissue contrast were maximized at 60 kVp. The 0.2 mm Cu filter achieved significantly higher CNRD for iodine contrast enhancement than the other two filters (p = 0.01), but microcalcification contrast and soft-tissue contrast were similar using the copper and aluminum filters. The average percent difference in linear attenuation coefficient, across all tube potentials, for polyethylene versus adipose tissue was 1.8%, 1.7%, and 1.3% for 0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn, respectively. For water versus glandular tissue, the average percent difference was 2.7%, 3.9%, and 4.2% for the three filter types. Contrast-enhanced bCT, using injected iodine contrast medium, may be optimized for maximum contrast of enhancing lesions at 60 kVp with 0.2 mm Cu filtration. Soft-tissue contrast and microcalcification contrast may also benefit from lower tube potentials (60 kVp). The linear attenuation coefficients of water and polyethylene slightly overestimate the values of their corresponding tissues, but the reported differences may serve as guidance for dosimetry and quality assurance using tissue equivalent phantoms.

  2. Iodine generator for reclaimed water purification

    NASA Technical Reports Server (NTRS)

    Wynveen, R. A.; Powell, J. D.; Schubert, F. H. (Inventor)

    1977-01-01

    The system disclosed is for controlling the iodine level in a water supply in a spacecraft. It includes an iodine accumulator which stores crystalline iodine, an electrochemical valve to control the input of iodine to the drinking water and an iodine dispenser. A pump dispenses fluid through the iodine dispenser and an iodine sensor to a potable water tank storage. The iodine sensor electronically detects the iodine level in the water, and through electronic means, produces a correction current control. The correction current control operates the electro-chemical iodine valve to release iodine from the iodine accumulator into the iodine dispenser.

  3. [Thyroid disease in the Czech Republic: the EUthyroid project and the evaluation of the General Health Insurance Company epidemiological data for the period of 2012-2015].

    PubMed

    Bílek, Radovan; Horáková, Lenka; Goš, Robert; Zamrazil, Václav

    Institute of Endocrinology participates in the grant of European Commission EUthyroid (Towards the elimination of iodine deficiency and preventable thyroid-related diseases in Europe), together with other 28 European countries. The role of Institute of Endocrinology in EUthyroid is among other things to ensure access to national registers relating to thyroid diseases. The results presented here correspond to the years 2012-2015 and are based on data from the General Health Insurance Company Czech Republic (VZP CR), which has 6 million insured persons (ratio male : female = 1 : 1). The set is sufficiently representative to be related to the whole of the Czech Republic. According to VZP data, the prevalence of thyreopathies is constantly increasing, for example according to the code of diagnoses E00-E07 and the unique birth number, the prevalence of thyreopathies increased from 6.8 % in 2012 to 7.5 % in 2015. The increase of the prevalence is mainly concentrated to clinical manifestation of hypothyroidism (code E03, an increase from 2.8 % in 2012 to 3.2 % in 2015); the second is nontoxic struma (code E04), which had a constant prevalence of 2.5 % in the given period. On the other hand, thyroiditis (code E06), the third in the order of occurrence, increased from 1.8 % in 2012 to 2 % in 2015. The decrease in prevalence only occurred in hyperthyroidism (E05) from 0.7 % in 2012 to 0.6 % in 2015. Other thyreopathies had a prevalence of less than 1 %, and was constant between 2012 and 2015 (other thyroid disorders E07 0.8 %, thyroid disorders associated with iodine deficiency E01 0.2 %, E02 0.07 %, E00 0.01 %, thyroid carcinoma C73 0.13 %).Key words: EUthyroid - General Health Insurance Company- occurrence of thyreopathies - thyroid disease in the Czech Republic.

  4. Increase in incidence of hyperthyroidism predominantly occurs in young people after iodine fortification of salt in Denmark.

    PubMed

    Bülow Pedersen, Inge; Laurberg, Peter; Knudsen, Nils; Jørgensen, Torben; Perrild, Hans; Ovesen, Lars; Rasmussen, Lone Banke

    2006-10-01

    To prevent goiter and nodular hyperthyroidism, iodine fortification (IF) of salt was introduced in Denmark in 1998. We prospectively registered all new cases of overt hyperthyroidism in two areas of Denmark before and for the first 6 yr after iodine fortification. We used a computer-based register of all new cases of hyperthyroidism in two population subcohorts with moderate iodine deficiency (Aalborg, n = 310,124) and mild iodine deficiency (Copenhagen, n = 225,707), respectively. Data were obtained 1) before IF (1997-1998); 2) during voluntary IF (1999-2000); 3) during the early (2001-2002) period of mandatory IF; and 4) during the late (2003-2004) period with mandatory IF. The overall incidence rate of hyperthyroidism increased [baseline, 102.8/100,000/year; voluntary IF, 122.8; early mandatory IF, 140.7; late mandatory IF, 138.7 (P for trend <0.001)]. Hyperthyroidism increased in both sexes (P < 0.001) and in all age groups: 0-19, 20-39, 40-59, and 60+ yr (P for trend <0.001). The increase was relatively highest in young adults aged 20-39 yr: late mandatory IF (percent increase from baseline), age 20-39, 160%, P < 0.001; age 40-59, 29%, P < 0.01; age 60+ yr, 13%, P = not significant. Even a cautious iodization of salt results in an increase in the incidence rate of hyperthyroidism. Contrary to current concepts, many of the new cases were observed in young subjects, and are presumably of autoimmune origin. Furthermore, monitoring is expected to show a decrease in the number of elderly subjects suffering from nodular hyperthyroidism.

  5. Dual-Energy Micro-CT Functional Imaging of Primary Lung Cancer in Mice Using Gold and Iodine Nanoparticle Contrast Agents: A Validation Study

    PubMed Central

    Ashton, Jeffrey R.; Clark, Darin P.; Moding, Everett J.; Ghaghada, Ketan; Kirsch, David G.; West, Jennifer L.; Badea, Cristian T.

    2014-01-01

    Purpose To provide additional functional information for tumor characterization, we investigated the use of dual-energy computed tomography for imaging murine lung tumors. Tumor blood volume and vascular permeability were quantified using gold and iodine nanoparticles. This approach was compared with a single contrast agent/single-energy CT method. Ex vivo validation studies were performed to demonstrate the accuracy of in vivo contrast agent quantification by CT. Methods Primary lung tumors were generated in LSL-KrasG12D; p53FL/FL mice. Gold nanoparticles were injected, followed by iodine nanoparticles two days later. The gold accumulated in tumors, while the iodine provided intravascular contrast. Three dual-energy CT scans were performed–two for the single contrast agent method and one for the dual contrast agent method. Gold and iodine concentrations in each scan were calculated using a dual-energy decomposition. For each method, the tumor fractional blood volume was calculated based on iodine concentration, and tumor vascular permeability was estimated based on accumulated gold concentration. For validation, the CT-derived measurements were compared with histology and inductively-coupled plasma optical emission spectroscopy measurements of gold concentrations in tissues. Results Dual-energy CT enabled in vivo separation of gold and iodine contrast agents and showed uptake of gold nanoparticles in the spleen, liver, and tumors. The tumor fractional blood volume measurements determined from the two imaging methods were in agreement, and a high correlation (R2 = 0.81) was found between measured fractional blood volume and histology-derived microvascular density. Vascular permeability measurements obtained from the two imaging methods agreed well with ex vivo measurements. Conclusions Dual-energy CT using two types of nanoparticles is equivalent to the single nanoparticle method, but allows for measurement of fractional blood volume and permeability with a single scan. As confirmed by ex vivo methods, CT-derived nanoparticle concentrations are accurate. This method could play an important role in lung tumor characterization by CT. PMID:24520351

  6. Effect of Dietary Intake of Stable Iodine on Dose-per-unit-intake Factors for 99Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.

    It is well-known that the human thyroid concentrates iodine more than 100 times the concentration in plasma. Also well-known is the fact that large amounts of stable iodine in the diet can limit thyroid uptake of total iodine; this is the basis for administering potassium iodide following a release of radioiodine from a nuclear reactor accident or nuclear weapon detonation. Many researchers have shown enhanced concentrations of both organic and inorganic iodine in saliva and breast milk. Technetium-99 is a long-lived (231,000 year half-life) radionuclide of concern in the management of high-level radioactive waste. There is no doubt that 99Tc,more » if it is in groundwater, will be found in the chemical form of pertechnetate, 99TcO4?. Pertechnetate is a large anion, almost identical in size to iodide, I?. The nuclear medicine literature shows that pertechnetate concentrates in the thyroid, salivary glands, and lactating breast in addition to the stomach, liver, and alimentary tract as currently recognized by the International Commission on Radiological Protection (ICRP). The fact that large intakes of stable iodine (127I) in the diet limit uptake of iodine by the thyroid leads one to generalize that stable iodine in the diet may also limit thyroid uptake of pertechnetate. While there is at least one report that iodine in the diet blocks uptake of 99mTcO4? by the thyroid and salivary glands (which have the same Na/I symporter, the biochemical concentration mechanism), the level of protective effect seen for blocking radioactive iodine is not expected for 99TcO4? because pertechnetate does not become organically bound in the thyroid and thus is not retained for months the way iodide is. While it does account for Tc concentration in the thyroid, the existing ICRP biokinetic model for technetium does not take enhanced concentrations in salivary gland and breast tissue into account. From the survey of the nuclear medicine literature, it is not possible to compute the effect of stable iodine in the diet on the dose per unit intake factors for 99Tc without developing an improved biokinetic model for technetium. Specific experiments should be designed to quantitatively evaluate 99TcO4? metabolism, excretion, and secretion, as well as to evaluate its chemical toxicity It is recommended that the ICRP reexamine its biokinetics models for Tc based on nuclear medicine data that have accumulated over the years. In particular, the ICRP ignores the lactation pathway, the enhanced concentration of Tc in breast and breast milk, and enhanced concentration of Tc (and I) in the salivary glands as well as in the thyroid. The ICRP should also explicitly incorporate the effect of stable iodine in the diet into both its models for iodine and technetium. The effect of concentration of Tc in breast milk needs further study for dosimetric implications to nursing infants whose mothers may ingest 99TcO4? from groundwater sources. The ICRP should also investigate the possibility of enhanced concentration of both I and Tc in the non-lactating female breast. To do these re-evaluations of biokinetic models, new experiments designed specifically to evaluate these questions concerning the biokinetics of Tc and I are needed.« less

  7. Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient head characteristics, as well as the choice of x-ray technique factors, affect lesion contrast and noise values in computed tomography (CT) images. Head sizes and mean Hounsfield unit (HU) values were obtained from head CT images for five classes of patients ranging from the newborn to adults. X-ray spectra with tube voltages ranging from 80 to 140 kV were used to compute the average photon energy, and energy fluence, transmitted through the heads of patients of varying size. Image contrast, and the corresponding contrast to noise ratios (CNRs), were determined for lesions of fat, muscle, and iodine relative to a uniform water background. Maintaining a constant image CNR for each lesion, the patient energy imparted was also computed to identify the x-ray tube voltage that minimized the radiation dose. For adults, increasing the tube voltage from 80 to 140 kV changed the iodine HU from 2.62 x 10(5) to 1.27 x 10(5), the fat HU from -138 to -108, and the muscle HU from 37.1 to 33.0. Increasing the x-ray tube voltage from 80 to 140 kV increased the percentage energy fluence transmission by up to a factor of 2. For a fixed x-ray tube voltage, the percentage transmitted energy fluence in adults was more than a factor of 4 lower than for newborns. For adults, increasing the x-ray tube voltage from 80 to 140 kV improved the CNR for muscle lesions by 130%, for fat lesions by a factor of 2, and for iodine lesions by 25%. As the size of the patient increased from newborn to adults, lesion CNR was reduced by about a factor of 2. The mAs value can be reduced by 80% when scanning newborns while maintaining the same lesion CNR as for adults. Maintaining the CNR of an iodine lesion at a constant level, use of 140 kV increases the energy imparted to an adult patient by nearly a factor of 3.5 in comparison to 80 kV. For fat and muscle lesions, raising the x-ray tube voltage from 80 to 140 kV at a constant CNR increased the patient dose by 37% and 7%, respectively. Our two key findings are that for head CT examinations performed at a constant CNR, the mAs can be substantially reduced when scanning infants, and that use of the lowest x-ray tube voltage will generally reduce patient doses.

  8. Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study

    PubMed Central

    Chen, Han; Xu, Cheng; Persson, Mats; Danielsson, Mats

    2015-01-01

    Abstract. Head computed tomography (CT) plays an important role in the comprehensive evaluation of acute stroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CT systems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information. Most importantly, the spectral information can be utilized to decompose the original set of energy-selective images into several basis function images that are inherently free of beam-hardening artifacts, a potential advantage for further improving the diagnosis accuracy. We are developing a photon-counting spectral detector for CT applications. The purpose of this work is to determine the optimal beam quality for material decomposition in two head imaging cases: nonenhanced imaging and K-edge imaging. A cylindrical brain tissue of 16-cm diameter, coated by a 6-mm-thick bone layer and 2-mm-thick skin layer, was used as a head phantom. The imaging target was a 5-mm-thick blood vessel centered in the head phantom. In K-edge imaging, two contrast agents, iodine and gadolinium, with the same concentration (5  mg/mL) were studied. Three parameters that affect beam quality were evaluated: kVp settings (50 to 130 kVp), filter materials (Z=13 to 83), and filter thicknesses [0 to 2 half-value layer (HVL)]. The image qualities resulting from the varying x-ray beams were compared in terms of two figures of merit (FOMs): squared signal-difference-to-noise ratio normalized by brain dose (SDNR2/BD) and that normalized by skin dose (SDNR2/SD). For nonenhanced imaging, the results show that the use of the 120-kVp spectrum filtered by 2 HVL copper (Z=29) provides the best performance in both FOMs. When iodine is used in K-edge imaging, the optimal filter is 2 HVL iodine (Z=53) and the optimal kVps are 60 kVp in terms of SDNR2/BD and 75 kVp in terms of SDNR2/SD. A tradeoff of 65 kVp was proposed to lower the potential risk of skin injuries if a relatively long exposure time is necessarily performed in the iodinated imaging. In the case of gadolinium imaging, both SD and BD can be minimized at 120 kVp filtered with 2 HVL thulium (Z=69). The results also indicate that with the same concentration and their respective optimal spectrum, the values of SDNR2/BD and SDNR2/SD in gadolinium imaging are, respectively, around 3 and 10 times larger than those in iodine imaging. However, since gadolinium is used in much lower concentrations than iodine in the clinic, iodine may be a preferable candidate for K-edge imaging. PMID:26835495

  9. Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study

    PubMed Central

    Shaffiq Said Rahmat, Said Mohd; Md Saad, Wan Mazlina

    2013-01-01

    The study aimed to investigate the effects of different tube potentials and concentrations of iodinated contrast media (CM) on the image enhancement, contrast-to-noise ratio (CNR) and noise in micro-computed tomography (µCT) images. A phantom containing of five polyethylene tube was filled with 2 mL of deionized water and iodinated CM (Omnipaque 300 mgI/mL) at four different concentrations: 5, 10, 15, and 20 mol/L, respectively. The phantom was scanned with a µCT machine (SkyScan 1176) using various tube potentials: 40, 50, 60, 70, 80, and 90 kVp, a fixed tube current; 100 µA, and filtration of 0.2 mm aluminum (Al). The percentage difference of image enhancement, CNR and noise of all images, acquired at different kVps and concentrations, were calculated. The image enhancement, CNR and noise curves with respect to tube potential and concentration were plotted and analysed. The highest image enhancement was found at the lowest tube potential of 40 kVp. At this kVp setting, the percentage difference of image enhancement [Hounsfield Unit (HU) of 20 mol/L iodine concentration over HU of deionized water] was 43%. By increasing the tube potential, it resulted with the reduction of HU, where only 17.5% different were noticed for 90 kVp. Across all iodine concentrations (5-20 M), CNR peaked at 80 kVp and then these values showed a slight decreasing pattern, which might be due insufficient tube current compensation. The percentage difference of image noise obtained at 40 and 90 kVp was 72.4%. Lower tube potential setting results in higher image enhancement (HU) in conjunction with increasing concentration of iodinated CM. Overall, the tube potential increment will substantially improve CNR and reduce image noise. PMID:24273743

  10. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer.

    PubMed

    Ghaghada, Ketan B; Sato, Amy F; Starosolski, Zbigniew A; Berg, John; Vail, David M

    2016-01-01

    Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of naturally occurring canine tumors.

  11. Dosimetry study of diagnostic X-ray using doped iodide normoxic polymer gels

    NASA Astrophysics Data System (ADS)

    Huang, Y. R.; Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Chu, C. H.; Hsieh, B. T.

    2014-11-01

    In radiotherapy, polymer gel dosimeters are used for three-dimensional (3D) dose distribution. However, the doses are within the Gy range. In this study, we attempted to develop a low-dose 3D dosimeter within the mGy range for diagnostic radiology. The effect of the iodinated compound was used as a dose enhancement sensitizer to enhance the dose sensitivity of normoxic polymer gel dosimeters. This study aims to use N-isopropylacrylamide(NIPAM)-based and methacrylic acid (MAGAT)-based gels to evaluate the potential dose enhancement sensitizer, as well as to compare two gels that may be suitable for measuring diagnostic radiation doses. The suitable formulation of NIPAM gel [5% (w/w) gelatin, 5% (w/w) NIPAM, 3% (w/w) N,N‧-methylenebisacrylamide (BIS), 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), and 87% (w/w) deionized distilled water] and MAGAT gel (4% MAA, 9% gelatin, 87% deionized water, and 10 mM THPC) were used and loaded with clinical iodinated contrast medium agent (Iobitridol, Xenetix® 350). Irradiation was conducted using X-ray computed tomography. The irradiation doses ranged from 0 mGy to 80 mGy. Optical computed tomography was the employed gel measurement system. The results indicate that the iodinated contrast agent yields a quantifiable dose enhancement ratio. The dose enhancement ratios of NIPAM and MAGAT gels are 3.35±0.6 and 1.36±0.3, respectively. The developed NIPAM gel in this study could be suitable for measuring diagnostic radiation doses.

  12. Investigation of x-ray spectra for iodinated contrast-enhanced dedicated breast CT

    PubMed Central

    Glick, Stephen J.; Makeev, Andrey

    2017-01-01

    Abstract. Screening for breast cancer with mammography has been very successful, resulting in part to a reduction of breast cancer mortality by approximately 39% since 1990. However, mammography still has limitations in performance, especially for women with dense breast tissue. Iodinated contrast-enhanced, dedicated breast CT (BCT) has been proposed to improve lesion analysis and the accuracy of diagnostic workup for patients suspected of having breast cancer. A mathematical analysis to explore the use of various x-ray filters for iodinated contrast-enhanced BCT is presented. To assess task-based performance, the ideal linear observer signal-to-noise ratio (SNR) is used as a figure-of-merit under the assumptions of a linear, shift-invariant imaging system. To estimate signal and noise propagation through the BCT detector, a parallel-cascade model was used. The lesion model was embedded into a structured background and included a realistic level of iodine uptake. SNR was computed for 84,000 different exposure settings by varying the kV setting, x-ray filter materials and thickness, breast size, and composition and radiation dose. It is shown that some x-ray filter material/thickness combinations can provide up to 75% improvement in the linear ideal observer SNR over a conventionally used x-ray filter for BCT. This improvement in SNR can be traded off for substantial reductions in mean glandular dose. PMID:28149923

  13. [Combined use of contrast media containing iodine and gadolinium for imaging and intervention : A hitherto widely ignored topic in radiological practice].

    PubMed

    Golder, W

    2012-02-01

    The synchronous use of chemically different contrast media in the same body compartment is a challenge for the radiologist, whether it is scheduled or unexpected. However, to inject contrast media containing iodine and gadolinium at the same time can be a prerequisite for the examination of several organs or organ systems. Unlike other topics of contrast-enhanced imaging procedures, the difficulties encountered with double contrast injections have been widely ignored in the literature. In the absence of reliable data from experimental and clinical studies the radiologist is dependent on case reports, information provided by the contrast media manufacturers, personal communications, mostly scanty personal experiences and a skilful time management, in order to overcome the situation. Only the combination of X-ray, computed tomography and magnetic resonance arthrography can be performed without another thought. However, the more or less synchronous vascular application of contrast media containing iodine and gadolinium requires vigilance. The more seriously ill the patient is, the more caution is advised even if the decision on the combined administration has to be reached urgently. The following overview gives a description of the properties of contrast media containing iodine and gadolinium as far as interactions following simultaneous administration are concerned. Subsequently, the clinically relevant situations and constellations are outlined and analyzed.

  14. Theoretical studies of solar lasers and converters

    NASA Technical Reports Server (NTRS)

    Heinbockel, John H.

    1990-01-01

    The research described consisted of developing and refining the continuous flow laser model program including the creation of a working model. The mathematical development of a two pass amplifier for an iodine laser is summarized. A computer program for the amplifier's simulation is included with output from the simulation model.

  15. Results of comparative RBMK neutron computation using VNIIEF codes (cell computation, 3D statics, 3D kinetics). Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grebennikov, A.N.; Zhitnik, A.K.; Zvenigorodskaya, O.A.

    1995-12-31

    In conformity with the protocol of the Workshop under Contract {open_quotes}Assessment of RBMK reactor safety using modern Western Codes{close_quotes} VNIIEF performed a neutronics computation series to compare western and VNIIEF codes and assess whether VNIIEF codes are suitable for RBMK type reactor safety assessment computation. The work was carried out in close collaboration with M.I. Rozhdestvensky and L.M. Podlazov, NIKIET employees. The effort involved: (1) cell computations with the WIMS, EKRAN codes (improved modification of the LOMA code) and the S-90 code (VNIIEF Monte Carlo). Cell, polycell, burnup computation; (2) 3D computation of static states with the KORAT-3D and NEUmore » codes and comparison with results of computation with the NESTLE code (USA). The computations were performed in the geometry and using the neutron constants presented by the American party; (3) 3D computation of neutron kinetics with the KORAT-3D and NEU codes. These computations were performed in two formulations, both being developed in collaboration with NIKIET. Formulation of the first problem maximally possibly agrees with one of NESTLE problems and imitates gas bubble travel through a core. The second problem is a model of the RBMK as a whole with imitation of control and protection system controls (CPS) movement in a core.« less

  16. Iodinated Al(III)-based phthalocyanines are promising sensitizers for dye-sensitized solar cells; a theoretical comparison between Zn(II), Mg(II), and Al(III)-based phthalocyanine sensitizers.

    PubMed

    Yang, Li-Na; Sun, Zhu-Zhu; Chen, Shi-Lu; Li, Ze-Sheng

    2014-02-24

    To design efficient dyes for dye-sensitized solar cells (DSSCs), using a Zn-coordinated phthalocyanine (TT7) as the prototype, a series of phthalocyanine dyes (Pcs) with different metal ions and peripheral/axial groups have been investigated by means of density functional theory (DFT) and time-dependent DFT (TDDFT) methods. Computational results show that the iodinated Al-based dye with a peripheral amino group (Al-I-NH2-Pc) exhibits the largest redshift in the maximum absorbance (λ(max)). In addition, Al-based dyes have appropriate energy-level arrangements of frontier orbitals to keep excellent balance between electron injection and regeneration of oxidized dyes. Further, it has been found that the intermolecular π-staking interaction in Al-I-Pc molecules is weaker than the other metal-based Pcs, which may effectively reduce dye aggregation on the semi-conductor surface. All these results suggest iodinated Al-based Pcs (Al-I-Pcs) to be potentially promising sensitizers in DSSCs. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Epigenetic modulators of thyroid cancer.

    PubMed

    Rodríguez-Rodero, Sandra; Delgado-Álvarez, Elías; Díaz-Naya, Lucía; Martín Nieto, Alicia; Menéndez Torre, Edelmiro

    2017-01-01

    There are some well known factors involved in the etiology of thyroid cancer, including iodine deficiency, radiation exposure at early ages, or some genetic changes. However, epigenetic modulators that may contribute to development of these tumors and be helpful to for both their diagnosis and treatment have recently been discovered. The currently known changes in DNA methylation, histone modifications, and non-coding RNAs in each type of thyroid carcinoma are reviewed here. Copyright © 2016 SEEN. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Performance Evaluation of a Field Programmable Gate Array-Based System for Detecting and Tracking Peer-to-Peer Protocols on a Gigabit Ethernet Network

    DTIC Science & Technology

    2010-06-01

    Ron’s Code 4 . . . . . . . . . . . . . . . . . . . 18 2.3.3 Virtual Private Network and Secure Shell Tunnels 19 2.3.4 Darknets ...created using Iodine. 2.2 Analyzing and Classifying Network Traffic Before the advent of Darknets and anonymizers like Tor (see Section 2.3), ana... darknets , and the Tor network. 2.3.1 Byte Padding. Byte padding is the most primitive obfuscation method used to hide payloads in network traffic. When byte

  19. Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.

    PubMed

    Nute, Jessica L; Jacobsen, Megan C; Stefan, Wolfgang; Wei, Wei; Cody, Dianna D

    2018-04-01

    A prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV-switching dual-energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight for this technology, with the goal of identifying relevant scan parameters and test metrics instrumental to the development of a dual-energy quality control (DEQC). A prototype elliptical phantom (effective diameter: 35 cm) was designed with multiple material inserts for DECT imaging. Inserts included tissue equivalent and material rods (including iodine and calcium at varying concentrations). The phantom was scanned on a fast kV-switching DECT system using 16 dual-energy acquisitions (CTDIvol range: 10.3-62 mGy) with varying pitch, rotation time, and tube current. The circular head phantom (22 cm diameter) was scanned using a similar protocol (12 acquisitions; CTDIvol range: 36.7-132.6 mGy). All acquisitions were reconstructed at 50, 70, 110, and 140 keV and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy, stability of monoenergetic reconstruction CT number, noise, and positional constancy. Variance component analysis was used to identify technique parameters that drove deviations in test metrics. Variances were compared to thresholds derived from manufacturer tolerances to determine technique parameters that had a nominally significant effect on test metrics. Iodine quantification error was largely unaffected by any of the technique parameters investigated. Monoenergetic HU stability was found to be affected by mAs, with a threshold under which spectral separation was unsuccessful, diminishing the utility of DECT imaging. Noise was found to be affected by CTDIvol in the DEQC body phantom, and CTDIvol and mA in the DEQC head phantom. Positional constancy was found to be affected by mAs in the DEQC body phantom and mA in the DEQC head phantom. A streamlined scan protocol was developed to further investigate the effects of CTDIvol and rotation time while limiting data collection to the DEQC body phantom. Further data collection will be pursued to determine baseline values and statistically based failure thresholds for the validation of long-term DECT scanner performance. © 2018 American Association of Physicists in Medicine.

  20. Stratified premedication strategy for the prevention of contrast media hypersensitivity in high-risk patients.

    PubMed

    Lee, Suh-Young; Yang, Min Suk; Choi, Young-Hoon; Park, Chang Min; Park, Heung-Woo; Cho, Sang Heon; Kang, Hye-Ryun

    2017-03-01

    Although the severity of hypersensitivity reactions to iodinated contrast media varies, it is well correlated with the severity of recurrent reactions; however, prophylaxis protocols are not severity-stratified. To assess the outcomes of tailored prophylaxis according to the severity of hypersensitivity reactions to iodinated contrast media. Our premedication protocols were stratified based on the severity of previous reactions: (1) 4 mg of chlorpheniramine for mild reactions, (2) adding 40 mg of methylprednisolone for moderate reactions, and (3) adding multiple doses of 40 mg of methylprednisolone for severe index reactions. Cases of reexposure in patients with a history of hypersensitivity reactions were routinely monitored and mandatorily recorded. Among a total of 850 patients who underwent enhanced computed tomography after severity-tailored prophylaxis, breakthrough reactions occurred in 17.1%, but most breakthrough reactions (89.0%) were mild and did not require medical treatment. Additional corticosteroid use did not reduce the breakthrough reaction rate in cases with a mild index reaction (16.8% vs 17.2%, P = .70). However, underpremedication with a single dose of corticosteroid revealed significantly higher rates of breakthrough reaction than did double doses of corticosteroid in cases with a severe index reaction (55.6% vs 17.4%, P = .02). Changing the iodinated contrast media resulted in an additional reduction of the breakthrough reaction rate overall (14.9% vs 32.1%, P = .001). In a total severity-based stratified prophylaxis regimens and changing iodinated contrast media can be considered in patients with a history of previous hypersensitivity reaction to iodinated contrast media to reduce the risk of breakthrough reactions. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  1. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study.

    PubMed

    Nagayama, Y; Nakaura, T; Oda, S; Tsuji, A; Urata, J; Furusawa, M; Tanoue, S; Utsunomiya, D; Yamashita, Y

    2018-02-01

    To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients. Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared. The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, p<0.01). Contrast enhancement, objective image noise, contrast-to-noise-ratio, and visual score of 100 kVp-S were similar to or better than of 120 kVp protocol. Compared with the 120 kVp protocol, the combined use of 100 kVp and SAFIRE in WBCT for oncology assessment with an SSCT facilitated substantial reduction in the CM and radiation dose while maintaining image quality. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Dual energy computed tomography for the head.

    PubMed

    Naruto, Norihito; Itoh, Toshihide; Noguchi, Kyo

    2018-02-01

    Dual energy CT (DECT) is a promising technology that provides better diagnostic accuracy in several brain diseases. DECT can generate various types of CT images from a single acquisition data set at high kV and low kV based on material decomposition algorithms. The two-material decomposition algorithm can separate bone/calcification from iodine accurately. The three-material decomposition algorithm can generate a virtual non-contrast image, which helps to identify conditions such as brain hemorrhage. A virtual monochromatic image has the potential to eliminate metal artifacts by reducing beam-hardening effects. DECT also enables exploration of advanced imaging to make diagnosis easier. One such novel application of DECT is the X-Map, which helps to visualize ischemic stroke in the brain without using iodine contrast medium.

  3. Development of High-Speed Fluorescent X-Ray Micro-Computed Tomography

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Tsuchiya, Y.; Kuroe, T.; Zeniya, T.; Wu, J.; Lwin, Thet-Thet; Yashiro, T.; Yuasa, T.; Hyodo, K.; Matsumura, K.; Dilmanian, F. A.; Itai, Y.; Akatsuka, T.

    2004-05-01

    A high-speed fluorescent x-ray CT (FXCT) system using monochromatic synchrotron x rays was developed to detect very low concentration of medium-Z elements for biomedical use. The system is equipped two types of high purity germanium detectors, and fast electronics and software. Preliminary images of a 10mm diameter plastic phantom containing channels field with iodine solutions of different concentrations showed a minimum detection level of 0.002 mg I/ml at an in-plane spatial resolution of 100μm. Furthermore, the acquisition time was reduced about 1/2 comparing to previous system. The results indicate that FXCT is a highly sensitive imaging modality capable of detecting very low concentration of iodine, and that the method has potential in biomedical applications.

  4. Development and application of the GIM code for the Cyber 203 computer

    NASA Technical Reports Server (NTRS)

    Stainaker, J. F.; Robinson, M. A.; Rawlinson, E. G.; Anderson, P. G.; Mayne, A. W.; Spradley, L. W.

    1982-01-01

    The GIM computer code for fluid dynamics research was developed. Enhancement of the computer code, implicit algorithm development, turbulence model implementation, chemistry model development, interactive input module coding and wing/body flowfield computation are described. The GIM quasi-parabolic code development was completed, and the code used to compute a number of example cases. Turbulence models, algebraic and differential equations, were added to the basic viscous code. An equilibrium reacting chemistry model and implicit finite difference scheme were also added. Development was completed on the interactive module for generating the input data for GIM. Solutions for inviscid hypersonic flow over a wing/body configuration are also presented.

  5. Method and apparatus for removing iodine from a nuclear reactor coolant

    DOEpatents

    Cooper, Martin H.

    1980-01-01

    A method and apparatus for removing iodine-131 and iodine-125 from a liquid sodium reactor coolant. Non-radioactive iodine is dissolved in hot liquid sodium to increase the total iodine concentration. Subsequent precipitation of the iodine in a cold trap removes both the radioactive iodine isotopes as well as the non-radioactive iodine.

  6. Effects of iodine in microbial control of dental treatment water.

    PubMed

    Puttaiah, Raghunath; Seibert, Jeff; Spears, Robert

    2011-05-01

    To determine the effects of low levels of iodine constantly present in the dental unit water system on microbial control of dental treatment water and biofilm control. This study used a dental unit water system simulator with eight dental unit waterline systems built to scale and function, each controlled via computer. Each of the eight units was operated independently, four units supplied with self-contained water reservoirs and four units supplied with municipal water. Four units were precleaned to remove biofilm buildup. The study had a well-balanced design with equal representation (variables) of presence/absence of biofilms, selfcontained reservoirs for introduction of treatment water, source water directly connected to municipal water source and iodinated cartridges within the self-contained reservoirs and between municipal water and dental unit. Point-of-use iodinated resin cartridges (IRC) were retrofitted proximal to handpiece and air/ water syringe tip lines in four units, and iodinated resin water cartridges (IRSWC) were fitted to the other four units at the source water output. Heterotrophic plate counts were performed at baseline and twice weekly for a period of 6 weeks. One representative waterline sample was taken from each group at baseline and end-of-study to analyze changes in biofilm status using scanning electron microscopy. Waterlines not previously contaminated with biofilms did not show organization of biofilm matrix in units equipped with IRSWC. Constantly present low levels of iodine, demonstrated some disruption of biofilms in waterlines already contaminated with mature biofilms. All groups showed contamination levels < 500 cfu/ml (colony forming units per milliliter) consistent with the CDC and ADA guidelines. In this 6 weeks study, IRSWC equipped waterlines showed disruption of established biofilms, controlled formation of new biofilms in clean lines and rendered the dental treatment water < 500 cfu/ml. Point-of-use iodinated resin cartridges were also effective in controlling contamination in the dental treatment water. Dental unit water systems that are in use get contaminated with microbes and biofilms in weeks of being put into use. These biofilms contaminate the treatment water thereby putting patients and staff at risk of infection by predominantly gram-negative microbes. Biofilms in the water systems must be cleaned periodically with a strong decontaminant and the dental treatment source water needs to be modified with a low-grade antimicrobial that can preserve the water quality yet safe to humans. In this translational research study, we evaluate the effects of elemental iodine dissolved in water flowing through an iodine containing cartridge in controlling biofilm and dental treatment water contamination using a dental unit water system simulator, prior to clinical utilization.

  7. [Study on the amount of daily iodine intake of inhabitants living in drinking water with excessive iodine content areas after termination of iodized salt supply].

    PubMed

    Zhang, Gen-hong; Li, Su-mei; Zheng, He-ming; Wang, Chuan-gang; Liu, Lie-jun; Li, Xiu-wei; Zhang, Hao-feng; Ke, Geng-yin; Ma, Jian-guo; Yang, Jin; Ma, Ying; Liu, Jin-wen

    2007-03-01

    To investigate the amount of daily iodine intake in the diet of the target population in drinking water with areas of excessive iodine after stopping supply of iodized salt, to provide evidence for developing strategies on control and prevention of excessive iodine. 335 objectives were selected by a two-stage sampling method in 4 administrative villages with different iodine contents in drinking water. The amount of drinking water intake and dietary survey for 335 people were done by a door-to-door survey,while the iodine contents in the drinking water of each selected family, local staple food and vegetable were measured. The median level of iodine in drinking water was 431.5 microg/L while the daily amount of iodine intake among the three groups of waters with different iodine contents were all greater than RNI. The daily iodine intake of local people was all greater than UL in the areas where the water iodine contents were more than 300 microg/L. It was of statistical sense that the iodine mean intake per capita per day of the three groups differed at different water iodine levels (P < 0.01). The iodine mean intake per capita per day of the three groups of different water iodine levels increased along with water iodine and showed a uptrend (P < 0.01). 83.2%-98.7% of the daily iodine intake of the three groups was from drinking water and 1.3%-16.8% came from food. The iodine intake had high-positive correlation relation with the content of water iodine (P < 0.01). It was concluded that drinking water was the main source of iodine intake in areas with iodine excessive water by the percentage of over 80%. It was necessary to adopt measures to improve the quality of water to decrease the iodine content other than just stopping supplies of iodized salt in the areas where the water iodine contents were greater than 300 microg/L, in order to prevent and control excessive intake of iodine.

  8. Iodine deficiency in pregnant women living in the South-East of the UK: the influence of diet and nutritional supplements on iodine status

    PubMed Central

    Bath, Sarah C.; Walter, Alan; Taylor, Andrew; Wright, John; Rayman, Margaret P.

    2015-01-01

    Iodine is a key component of the thyroid hormones which are crucial for brain development. Pregnant women are vulnerable to iodine deficiency because their requirement for iodine is higher than that of non-pregnant adults. Data on the iodine status of UK pregnant women are sparse and there are no such data in the South East. One hundred pregnant women were recruited to a cross-sectional study at the Royal Surrey County Hospital, Guildford, at their first-trimester visit for an ultrasound scan. Participants provided a spot-urine sample (for the measurement of urinary iodine and creatinine concentrations) and 24-hour excretion of iodine was estimated from the urinary iodine-to-creatinine ratio. Women completed a general questionnaire and a food-frequency questionnaire. The median urinary iodine concentration (85·3 μg/l) indicated that the group was iodine deficient by WHO criteria. The median values of the iodine-to-creatinine ratio (122·9 μg/g) and of the estimated 24-hr iodine excretion (151·2 μg/day) were also suggestive of iodine deficiency. Urinary iodine concentration was significantly higher in women taking an iodine-containing prenatal supplement (n=42) than in those not taking such a supplement (P<0·001). In adjusted analyses, milk intake, maternal age and iodine-containing prenatal supplement use were positively associated with estimated 24-hour urinary iodine excretion. Our finding of iodine deficiency in these women gives cause for concern. We suggest that women of childbearing age and pregnant women should be given advice on how to improve their iodine status through dietary means. A national survey of iodine status in UK pregnant women is required. PMID:24398008

  9. Biofortification of lettuce (Lactuca sativa L.) with iodine: the effect of iodine form and concentration in the nutrient solution on growth, development and iodine uptake of lettuce grown in water culture.

    PubMed

    Voogt, Wim; Holwerda, Harmen T; Khodabaks, Rashied

    2010-04-15

    Iodine is an essential trace element for humans. Two billion individuals have insufficient iodine intake. Biofortification of vegetables with iodine offers an excellent opportunity to increase iodine intake by humans. The main aim was to study the effect of iodine form and concentration in the nutrient solution on growth, development and iodine uptake of lettuce, grown in water culture. In both a winter and summer trial, dose rates of 0, 13, 39, 65, and 90 or 129 microg iodine L(-1), applied as iodate (IO(3)(-)) or iodide (I(-)), did not affect plant biomass, produce quality or water uptake. Increases in iodine concentration significantly enhanced iodine content in the plant. Iodine contents in plant tissue were up to five times higher with I(-) than with IO(3)(-). Iodine was mainly distributed to the outer leaves. The highest iodide dose rates in both trials resulted in 653 and 764 microg iodine kg(-1) total leaf fresh weight. Biofortification of lettuce with iodine is easily applicable in a hydroponic growing system, both with I(-) and IO(3)(-). I(-) was more effective than IO(3)(-). Fifty grams of iodine-biofortified lettuce would provide, respectively, 22% and 25% of the recommended daily allowance of iodine for adolescents and adults. (c) 2010 Society of Chemical Industry.

  10. [Iodine concentration in cooking salt consumed in Lubumbashi and the iodine status of vulnerable people: case study of pregnant women living in underprivileged areas].

    PubMed

    Banza, Bienvenue Ilunga; Lumbu, Jean Baptiste Simbi; Donnen, Philippe; Twite, Eugène Kabange; Kwete, Daniel Mikobi; Kazadi, Costa Mwadianvita; Ozoza, Jean Okolonken; Habimana, Laurence; Kalenga, Prosper Muenze Kayamba; Robert, Annie

    2016-01-01

    Consumption of low iodine salt can cause different types of disorders associated with iodine deficiency. This study aims to determine iodine content in table salt consumed in Lubumbashi and iodine status of pregnant women who are the main target of iodine deficiency. aAdescriptive cross-sectional study was devoted to an iodometric iodine analysis of 739 salt samples collected from the households and the markets of Lubumbashi in 2014. Previously, urinary iodine concentrations were determined in 225 pregnant women received for consultation from 15 March 2009 to 25 April 2011 by mineralization technique using ammonium persulphate. Our survey found that 47.5% of the cooking salt samples were adequately iodized (from 15 to 40 ppm), 36,9% of the samples had low iodine levels, 7,4% of the samples had too much iodine and 8,1% of the samples were not iodized. Iodine concentration in the analyzed cooking salt reached an overall average of 54,9%, being clearly below the WHO Standards (90%). By measuring urinary iodine concentration of pregnant women, iodine deficiency (urinary iodine <150 µg/l) was observed in 52%. The low availability of iodine from consumed salt in Lubumbashi could be responsible for a large proportion of the observed iodine deficiency in pregnant women, exposing them to the major risks for disorders associated with iodine deficiency.

  11. Risk of Suboptimal Iodine Intake in Pregnant Norwegian Women

    PubMed Central

    Brantsæter, Anne Lise; Abel, Marianne Hope; Haugen, Margaretha; Meltzer, Helle Margrete

    2013-01-01

    Pregnant women and infants are exceptionally vulnerable to iodine deficiency. The aims of the present study were to estimate iodine intake, to investigate sources of iodine, to identify predictors of low or suboptimal iodine intake (defined as intakes below 100 μg/day and 150 μg/day) in a large population of pregnant Norwegian women and to evaluate iodine status in a sub-population. Iodine intake was calculated based on a validated Food Frequency Questionnaire in the Norwegian Mother and Child Cohort. The median iodine intake was 141 μg/day from food and 166 μg/day from food and supplements. Use of iodine-containing supplements was reported by 31.6%. The main source of iodine from food was dairy products, contributing 67% and 43% in non-supplement and iodine-supplement users, respectively. Of 61,904 women, 16.1% had iodine intake below 100 μg/day, 42.0% had iodine intake below 150 μg/day and only 21.7% reached the WHO/UNICEF/ICCIDD recommendation of 250 μg/day. Dietary behaviors associated with increased risk of low and suboptimal iodine intake were: no use of iodine-containing supplements and low intake of milk/yogurt, seafood and eggs. The median urinary iodine concentration measured in 119 participants (69 μg/L) confirmed insufficient iodine intake. Public health strategies are needed to improve and secure the iodine status of pregnant women in Norway. PMID:23389302

  12. Risk of suboptimal iodine intake in pregnant Norwegian women.

    PubMed

    Brantsæter, Anne Lise; Abel, Marianne Hope; Haugen, Margaretha; Meltzer, Helle Margrete

    2013-02-06

    Pregnant women and infants are exceptionally vulnerable to iodine deficiency. The aims of the present study were to estimate iodine intake, to investigate sources of iodine, to identify predictors of low or suboptimal iodine intake (defined as intakes below 100 μg/day and 150 μg/day) in a large population of pregnant Norwegian women and to evaluate iodine status in a sub-population. Iodine intake was calculated based on a validated Food Frequency Questionnaire in the Norwegian Mother and Child Cohort. The median iodine intake was 141 μg/day from food and 166 μg/day from food and supplements. Use of iodine-containing supplements was reported by 31.6%. The main source of iodine from food was dairy products, contributing 67% and 43% in non-supplement and iodine-supplement users, respectively. Of 61,904 women, 16.1% had iodine intake below 100 μg/day, 42.0% had iodine intake below 150 μg/day and only 21.7% reached the WHO/UNICEF/ICCIDD recommendation of 250 μg/day. Dietary behaviors associated with increased risk of low and suboptimal iodine intake were: no use of iodine-containing supplements and low intake of milk/yogurt, seafood and eggs. The median urinary iodine concentration measured in 119 participants (69 μg/L) confirmed insufficient iodine intake. Public health strategies are needed to improve and secure the iodine status of pregnant women in Norway.

  13. MO-F-CAMPUS-J-01: Effect of Iodine Contrast Agent Concentration On Cerebrovascular Dose for Synchrotron Radiation Microangiography Based On a Simple Mouse Head Model and a Voxel Mouse Head Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, H; Jing, J; Xie, C

    Purpose: To find effective setting methods to mitigate the irradiation injure in synchrotron radiation microangiography(SRA) by Monte Carlo simulation. Methods: A mouse 1-D head model and a segmented voxel mouse head phantom were simulated by EGSnrc/Dosxyznrc code to investigate the dose enhancement effect of the iodine contrast agent irradiated by a monochromatic synchrotron radiation(SR) source. The influence of, like iodine concentration (IC), vessel width and depth, with and without skull layer protection and the various incident X ray energies, were simulated. The dose enhancement effect and the absolute dose based on the segmented voxel mouse head phantom were evaluated. Results:more » The dose enhancement ratio depends little on the irradiation depth, but strongly on the IC, which is linearly increases with IC. The skull layer protection cannot be ignored in SRA, the 700µm thick skull could decrease 10% of the dose. The incident X-ray energy can significantly affact the dose. E.g. compared to the dose of 33.2keV for 50mgI/ml, the 32.7keV dose decreases 38%, whereas the dose of 33.7 keV increases 69.2%, and the variation will strengthen more with enhanced IC. The segmented voxel mouse head phantom also showed that the average dose enhancement effect and the maximal voxel dose per photon depends little on the iodine voxel volume ratio, but strongly on IC. Conclusion: To decrease dose damage in SRA, the high-Z contrast agent should be used as little as possible, and try to avoid radiating locally the injected position immediately after the contrast agent injection. The fragile vessel containing iodine should avoid closely irradiating. Avoiding irradiating through the no or thin skull region, or appending thin equivalent material from outside to protect is also a better method. As long as SRA image quality is ensured, using incident X-ray energy as low as possible.« less

  14. WE-FG-207B-08: Dual-Energy CT Iodine Accuracy Across Vendors and Platforms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobsen, M; Wood, C; Cody, D

    Purpose: Although a major benefit of dual-energy CT is its quantitative capabilities, it is critical to understand how results vary by scanner manufacturer and/or model before making clinical patient management decisions. Each manufacturer utilizes a specific dual-energy CT approach; cross-calibration may be required for facilities with more than one dual-energy CT scanner type. Methods: A solid dual-energy quality control phantom (Gammex, Inc.; Appleton, WI) representing a large body cross-section containing three Iodine inserts (2mg/ml, 5mg/ml, 15 mg/ml) was scanned on these CT systems: GE HD-750 (80/140kVp), prototype GE Revolution CT with GSI (80/140kVp), Siemens Flash (80/140kVp and 100/140kVp), and Philipsmore » IQon (120kVp and 140kVp). Iodine content was measured in units of concentration (mg/ml) from a single 5mm-thick central image. Three to five acquisitions were performed on each scanner platform in order to compute standard deviation. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were as consistent as possible (thickness, kernel, no noise reduction applied). Results: Iodine measurement error ranges were −0.24-0.16 mg/ml for the 2mg/ml insert (−12.0 − 8.0%), −0.28–0.26 mg/ml for the 5mg/ml insert (−5.6 − 5.2%), and −1.16−0.99 mg/ml for the 15mg/ml insert (−7.7 − 6.6%). Standard deviations ranged from 0 to 0.19 mg/ml for the repeated acquisitions from each scanner. The average iodine measurement error and standard deviation across all systems and inserts was −0.21 ± 0.48 mg/ml (−1.5 ± 6.48%). The largest absolute measurement error was found in the 15mg/ml iodine insert. Conclusion: There was generally good agreement in Iodine quantification across 3 dual-energy CT manufacturers and 4 scanner models. This was unexpected given the widely different underlying dual-energy CT mechanisms employed. Future work will include additional scanner platforms, independent verification of the Iodine insert standard concentrations (especially the 15 mg/ml insert), and how much measurement variability can be clinically tolerated. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.« less

  15. Neonatal hypothyroid screening in monitoring of iodine deficiency and iodine supplementation in Poland.

    PubMed

    Ołtarzewski, M; Szymborski, J

    2003-01-01

    Neonatal hypothyroid screening in Poland is standardised and all newborns screening data are registered in central data base in the National Institute of Mother and Child. About 400,000 newborns are screened per year for hypothyroidism (TSH) and phenylketonuria (PKU). Unfortunately, obstetric clinics still use antiseptics that contain iodine. According to our data 71% of clinics used iodine in 1998 (58% iodine tincture and 13% povidone iodine) and 58.2% (35.4 iodine tincture and 13% povidone iodine) in the year 2000. Presence of iodine resulted in over 3 times increase of a percentage of TSH levels over cut off, increasing the number of false positives in the hypothyroid screening. Analysis of TSH distribution for iodine containing and iodine free hospitals gave totally different estimation of iodine deficiency according to WHO criteria. In the group of iodine free hospitals 24 regions were classified as not deficient, 9 regions were borderline with a fraction of TSH levels over 5 mlU/l of 3-5%. 10 regions could not be analysed because all hospitals declared use of iodine. In the second group all regions were iodine deficient. TSH distribution since 1994 shows significant decrease of percentage of TSH levels over cut off from 2.23% in 1994 to 0.16 in 1997 and to 0.12 in 2000. These changes are most probably connected with successive introduction of iodine supplementation which became obligatory in 1997 and suggest that iodine supplementation covers iodine requirements during pregnancy. Iodine deficiency and iodine supplementation in Poland can be studied using TSH blood spot newborn screening results in correlation with data on interfering factors and in reference to modified criteria for the analytical test and the population. To reduce false positive rate in neonatal hypothyroid screening iodine containing antiseptics, particularly iodine tincture, should be withdrawn from all obstetrics clinics in Poland.

  16. Iodine Deficiency and Excess Coexist in China and Induce Thyroid Dysfunction and Disease: A Cross-Sectional Study

    PubMed Central

    Meng, Fangang; Liu, Shoujun; Fan, Zhipeng; Wu, Junhua; Sun, Dianjun

    2014-01-01

    Background In spite of the salt iodization, iodine deficiency disorders (IDD) have not been sustainably eliminated in China. There are coastal areas with low iodized salt coverage rates (iodine nutrition is inadequate) and other areas with excessive amounts of iodine in the drinking water. Objective This study aimed to clarify the association of iodine deficiencies resulting from a low coverage rate of iodized salt, excess iodine intake from drinking water with thyroid function and disease in adults. Design A cross-sectional study was conducted in adults in different iodine nutrition areas in three provinces in China. Results The prevalence of thyroid nodules was 15.52%, 8.66% and 22.17% in the iodine excess, sufficient and deficient groups, respectively. The prevalence of subclinical hypothyroidism was 20.09%, 10.41%, and 2.25% in the excess, sufficient and deficient iodine groups, respectively. The prevalence of subclinical hyperthyroidism and overt hyperthyroidism in the iodine deficient group was higher than that in the iodine excess group ( = 9.302, p = 0.002) and iodine sufficient group ( = 7.553, p = 0.006). Thyroid-stimulating hormone (TSH) was significantly correlated with excess iodine intake (β = 1.764,P = 0.001) and deficient iodine intake (β = −1.219, P = 0.028). Conclusions Thyroid nodules are more likely to be present in the iodine excess and deficient areas than in the iodine sufficient areas. Subclinical hyperthyroidism and overt hyperthyroidism are more likely to be prevalent in the iodine deficient areas than in the iodine excess or sufficient areas. Subclinical hypothyroidism is more likely to be prevalent in the high iodine intake areas than in the iodine deficient or sufficient areas. Median TSH may be deemed as an alternative indicator for monitoring the iodine nutrition status of the adult population in iodine excess and deficient areas. PMID:25375854

  17. Iodine Deficiency and Iodine Prophylaxis in Pregnancy.

    PubMed

    Trofimiuk-Mudlner, Malgorzata; Hubalewska-Dydejczyk, Alicja

    2017-01-01

    Physiological changes in pregnancy result in increased iodine demand, which may not be met in areas of mild-to-moderate iodine deficiency or borderline sufficiency. As a pregnant woman is the only source of thyroid hormones for her child during early gestation, iodine deficiencyinduced hypothyroxinemia may have deleterious effects on fetal development. To present the current approach to iodine deficiency and its prophylaxis during pregnancy. A review of the current literature including patents on iodine deficiency in pregnancy has been performed. Negative influence of severe iodine deficiency on fetal development has been proved, and evidence on a deleterious impact of milder forms of iodine deficiency on cognition of the offspring is rapidly growing. Although the WHO has addressed the issues of monitoring iodine status during pregnancy, prophylactic measures and assessment of their effectiveness, there are some controversies, regarding for example the best methods for control of iodine status. New patents in urinary iodine measurement methods may make iodine nutrition monitoring easier. The main method of iodine prophylaxis, in pregnancy also, is universal salt iodization. However, particularly if there is not sufficient coverage of the households with iodized salt, additional measures, such as oral supplementation with potassium iodide tablets, are necessary in pregnant women to provide adequate iodine nutrition. Iodine supplementation improves maternal thyroid function indices; particularly, it prevents goiter formation. Stronger evidence on beneficial effects of iodine supplementation of mild-to-moderate iodine deficient pregnant women on cognitive function of their children is still needed. It may be provided by randomized controlled trials and international initiatives. Changes in the iodine prophylaxis system should be monitored, both to prevent decreased or excessive iodine intake. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Optimal iodine staining of cardiac tissue for X-ray computed tomography.

    PubMed

    Butters, Timothy D; Castro, Simon J; Lowe, Tristan; Zhang, Yanmin; Lei, Ming; Withers, Philip J; Zhang, Henggui

    2014-01-01

    X-ray computed tomography (XCT) has been shown to be an effective imaging technique for a variety of materials. Due to the relatively low differential attenuation of X-rays in biological tissue, a high density contrast agent is often required to obtain optimal contrast. The contrast agent, iodine potassium iodide ([Formula: see text]), has been used in several biological studies to augment the use of XCT scanning. Recently I2KI was used in XCT scans of animal hearts to study cardiac structure and to generate 3D anatomical computer models. However, to date there has been no thorough study into the optimal use of I2KI as a contrast agent in cardiac muscle with respect to the staining times required, which has been shown to impact significantly upon the quality of results. In this study we address this issue by systematically scanning samples at various stages of the staining process. To achieve this, mouse hearts were stained for up to 58 hours and scanned at regular intervals of 6-7 hours throughout this process. Optimal staining was found to depend upon the thickness of the tissue; a simple empirical exponential relationship was derived to allow calculation of the required staining time for cardiac samples of an arbitrary size.

  19. Development of Databases on Iodine in Foods and Dietary Supplements

    PubMed Central

    Ershow, Abby G.; Skeaff, Sheila A.; Merkel, Joyce M.; Pehrsson, Pamela R.

    2018-01-01

    Iodine is an essential micronutrient required for normal growth and neurodevelopment; thus, an adequate intake of iodine is particularly important for pregnant and lactating women, and throughout childhood. Low levels of iodine in the soil and groundwater are common in many parts of the world, often leading to diets that are low in iodine. Widespread salt iodization has eradicated severe iodine deficiency, but mild-to-moderate deficiency is still prevalent even in many developed countries. To understand patterns of iodine intake and to develop strategies for improving intake, it is important to characterize all sources of dietary iodine, and national databases on the iodine content of major dietary contributors (including foods, beverages, water, salts, and supplements) provide a key information resource. This paper discusses the importance of well-constructed databases on the iodine content of foods, beverages, and dietary supplements; the availability of iodine databases worldwide; and factors related to variability in iodine content that should be considered when developing such databases. We also describe current efforts in iodine database development in the United States, the use of iodine composition data to develop food fortification policies in New Zealand, and how iodine content databases might be used when considering the iodine intake and status of individuals and populations. PMID:29342090

  20. Energy-discriminating X-ray computed tomography system utilizing a cadmium telluride detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Takahasi, Kiyomi; Sato, Shigehiro; Ogawae, Akira; Onagawa, Jun

    2010-07-01

    An energy-discriminating K-edge X-ray computed tomography (CT) system is useful for increasing contrast resolution of a target region utilizing contrast media and for reducing the absorbed dose for patients. The CT system is of the first-generation type with a cadmium telluride (CdTe) detector, and a projection curve is obtained by translation scanning using the CdTe detector in conjunction with an x-stage. An object is rotated by the rotation step angle using a turntable between the translation scans. Thus, CT is carried out by repeating the translation scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced using charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selecting photons with energies just beyond the iodine K-edge energy of 33.2 keV.

  1. Fluorescent x-ray computed tomography to visualize specific material distribution

    NASA Astrophysics Data System (ADS)

    Takeda, Tohoru; Yuasa, Tetsuya; Hoshino, Atsunori; Akiba, Masahiro; Uchida, Akira; Kazama, Masahiro; Hyodo, Kazuyuki; Dilmanian, F. Avraham; Akatsuka, Takao; Itai, Yuji

    1997-10-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT systems consists of a silicon channel cut monochromator, an x-ray slit and a collimator for detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the K(alpha) line, incident monochromatic x-ray was set at 37 keV. At 37 keV Monte Carlo simulation showed almost complete separation between Compton scattering and the K(alpha) line. Actual experiments revealed small contamination of Compton scattering on the K(alpha) line. A clear FXCT image of a phantom was obtained. Using this system the minimal detectable dose of iodine was 30 ng in a volume of 1 mm3, and a linear relationship was demonstrated between photon counts of fluorescent x-rays and the concentration of iodine contrast material. The use of high incident x-ray energy allows an increase in the signal to noise ratio by reducing the Compton scattering on the K(alpha) line.

  2. Effects of iodine deficiency in pregnancy.

    PubMed

    Pearce, Elizabeth N

    2012-06-01

    Dietary iodine requirements are increased in pregnancy due to increased thyroid hormone production, increased renal iodine losses, and fetal iodine requirements. Adverse effects of iodine deficiency in pregnancy include maternal and fetal goiter, cretinism, intellectual impairments, neonatal hypothyroidism, and increased pregnancy loss and infant. Dietary iodine requirements remain increased in lactation due to the concentration of iodine in breast milk. Iodine deficiency remains a significant global public health problem. Excess iodine ingestion in pregnancy, while a relatively uncommon problem, may also have adverse fetal effects. However, the safe upper limit for chronic iodine ingestion in pregnancy and lactation is not currently well defined. Copyright © 2012 Elsevier GmbH. All rights reserved.

  3. Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes

    NASA Astrophysics Data System (ADS)

    André, T.; Morini, F.; Karamitros, M.; Delorme, R.; Le Loirec, C.; Campos, L.; Champion, C.; Groetz, J.-E.; Fromm, M.; Bordage, M.-C.; Perrot, Y.; Barberet, Ph.; Bernal, M. A.; Brown, J. M. C.; Deleuze, M. S.; Francis, Z.; Ivanchenko, V.; Mascialino, B.; Zacharatou, C.; Bardiès, M.; Incerti, S.

    2014-01-01

    Monte Carlo simulations of S-values have been carried out with the Geant4-DNA extension of the Geant4 toolkit. The S-values have been simulated for monoenergetic electrons with energies ranging from 0.1 keV up to 20 keV, in liquid water spheres (for four radii, chosen between 10 nm and 1 μm), and for electrons emitted by five isotopes of iodine (131, 132, 133, 134 and 135), in liquid water spheres of varying radius (from 15 μm up to 250 μm). The results have been compared to those obtained from other Monte Carlo codes and from other published data. The use of the Kolmogorov-Smirnov test has allowed confirming the statistical compatibility of all simulation results.

  4. Quantitative contrast-enhanced spectral mammography based on photon-counting detectors: A feasibility study.

    PubMed

    Ding, Huanjun; Molloi, Sabee

    2017-08-01

    To investigate the feasibility of accurate quantification of iodine mass thickness in contrast-enhanced spectral mammography. A computer simulation model was developed to evaluate the performance of a photon-counting spectral mammography system in the application of contrast-enhanced spectral mammography. A figure-of-merit (FOM), which was defined as the decomposed iodine signal-to-noise ratio (SNR) with respect to the square root of the mean glandular dose (MGD), was chosen to optimize the imaging parameters, in terms of beam energy, splitting energy, and prefiltrations for breasts of various thicknesses and densities. Experimental phantom studies were also performed using a beam energy of 40 kVp and a splitting energy of 34 keV with 3 mm Al prefiltration. A two-step calibration method was investigated to quantify the iodine mass thickness, and was validated using phantoms composed of a mixture of glandular and adipose materials, for various breast thicknesses and densities. Finally, the traditional dual-energy log-weighted subtraction method was also studied as a comparison. The measured iodine signal from both methods was compared to the known value to characterize the quantification accuracy and precision. The optimal imaging parameters, which lead to the highest FOM, were found at a beam energy between 42 and 46 kVp with a splitting energy at 34 keV. The optimal tube voltage decreased as the breast thickness or the Al prefiltration increased. The proposed quantification method was able to measure iodine mass thickness on phantoms of various thicknesses and densities with high accuracy. The root-mean-square (RMS) error for cm-scale lesion phantoms was estimated to be 0.20 mg/cm 2 . The precision of the technique, characterized by the standard deviation of the measurements, was estimated to be 0.18 mg/cm 2 . The traditional weighted subtraction method also predicted a linear correlation between the measured signal and the known iodine mass thickness. However, the correlation slope and offset values were strongly dependent on the total breast thickness and density. The results of this study suggest that iodine mass thickness for cm-scale lesions can be accurately quantified with contrast-enhanced spectral mammography. The quantitative information can potentially improve the differential power for malignancy. © 2017 American Association of Physicists in Medicine.

  5. Iodine intake and status of UK women of childbearing age recruited at the University of Surrey in the winter

    PubMed Central

    Bath, Sarah C.; Sleeth, Michelle L.; McKenna, Marianne; Walter, Alan; Taylor, Andrew; Rayman, Margaret P.

    2015-01-01

    As intra-thyroidal iodine stores should be maximised before conception to facilitate the increased thyroid-hormone production of pregnancy, women who may become pregnant should ideally consume 150 μg iodine/day [US Recommended Dietary Allowance (RDA)]. As few UK data exist in this population group, our aim was to assess iodine intake and status in women of childbearing age in a cross-sectional study at the University of Surrey. Total iodine excretion was measured from 24-h urine samples in 57 women; iodine intake was estimated by assuming that 90% of ingested iodine was excreted. Average iodine intake was also estimated from 48-h food diaries that the women completed. The median urinary-iodine concentration (63.1 μg/L) classified the group as mildly iodine deficient by WHO criteria. By contrast, the median 24-h iodine excretion (149.8 μg/24-h), suggested a relatively low risk of iodine deficiency. Median estimated iodine intake, extrapolated from urinary excretion, was 167 μg/day, whereas it was lower, at 123 μg/day, when estimated from the 48-h food-diaries. Iodine intake from food diaries and 24-h iodine excretion were strongly correlated (r=0.75, p<0.001). Intake of milk, eggs and dairy products was positively associated with iodine status. The iodine status of this UK cohort is probably a best-case scenario as the women were mostly nutrition students and were recruited in the winter when milk-iodine content is at its highest; further study in more representative cohorts of UK women is required. Our study highlights a need for revised cut-offs for iodine deficiency that are method- and age-group specific. PMID:25274294

  6. Iodine status in pregnancy and household salt iodine content in rural Bangladesh.

    PubMed

    Shamim, Abu Ahmed; Christian, Parul; Schulze, Kerry J; Ali, Hasmot; Kabir, Alamgir; Rashid, Mahbubur; Labrique, Alain; Salamatullah, Qauzi; West, Keith P

    2012-04-01

    Adequate maternal iodine intake is essential during pregnancy for the development of the foetus. To assess the extent of iodine insufficiency and its association with household iodized salt in rural Bangladesh, we measured urinary iodine and household salt iodine content among pregnant women in early (≤16 weeks, n = 1376) and late (≥32 weeks, n = 1114) pregnancy. Salt (∼20 g) and a spot urine sample (∼10 mL) were collected from women participating in a randomized, placebo-controlled trial of vitamin A or beta-carotene supplementation in rural northwestern Bangladesh during home visits in early and late pregnancy. Salt iodine was analyzed by iodometric titration, and urinary iodine by the Ohashi method. Almost all salt samples had some detectable iodine, but over 75% contained <15 ppm. Median (interquartile range) urinary iodine concentrations were 66 (34-133) and 55 (28-110) µg L⁻¹ in early and late pregnancy, respectively; urinary iodine <150 µg L⁻¹ was found in ∼80% of women at both times in pregnancy. Although the risk of iodine insufficiency declined with increasing iodine content of household salt (P for trend <0.05), median urinary iodine did not reach 150 µg L⁻¹ until iodine in household salt was at least 32 ppm and 51 ppm during early and late pregnancy, respectively. Despite a national policy on universal salt iodization, salt iodine content remains insufficient to maintain adequate maternal iodine status throughout pregnancy in rural northern Bangladesh. Alternative measures like direct iodine supplementation during pregnancy could be considered to assure adequate iodine status during this high-risk period of life. © 2010 Blackwell Publishing Ltd.

  7. Urinary and Milk Iodine Status in Neonates and Their Mothers during Congenital Hypothyroidism Screening Program in Eastern Azerbaijan: A Pilot Study

    PubMed Central

    MOBASSERI, Majid; ROSHANRAVAN, Neda; MESRI ALAMDARI, Naimeh; OSTADRAHIMI, Alireza; ASGHARI JAFARABADI, Mohammad; ANARI, Farideh; HEDAYATI, Mehdi

    2014-01-01

    Abstract Background Iodine is essential element in thyroid hormones synthesis and normal growth and development of the brain. Milk and iodine concentrations can be appropriate indicator of body iodine status; in this study, we evaluated the concentrations of urine and milk iodine in newborns and their mothers. Methods In a cross-sectional study conducted in 2013, urine and milk iodine in 106 neonates and their mothers referred to healthcare center in Shabestar, Eastern Azerbaijan for congenital hypothyroidism screening program were determined. Median urinary iodine < 100 µg/L and milk iodine < 50 µg/L was considered as iodine deficiency. Results The median urine iodine concentrations (UIC) in mothers and infants were 142.31 µg/L (.0 - 1260) and 306.76 µg/L (23.56-1020) respectively. Urine iodine concentrations were < 100 µg/L in 33.9% of mothers and 14.2% of neonates. The median milk iodine concentration (MIC) was 58.23 µg/L (20.31- 425) and in 41.9% of mothers was <50 µg/L. A positive significant correlation was found between milk iodine and maternal urinary iodine concentration (r=0.533, P= 0.000). There was significant correlation between neonatal UIC and maternal UIC (r=0.462, P= 0.000), neonatal UIC and MIC (r=0.414, P= 0.000). Conclusions Urinary and milk iodine concentrations in mothers and infants were within acceptable range, which indicates adequate iodine intake. However, there were moderate and marginal iodine deficiencies in about half percentage of participants. Insufficient amount of milk iodine in about half of the mothers can result in iodine deficiency in breast-fed infants. PMID:26060700

  8. Antibiofouling polymer-coated gold nanoparticles as a contrast agent for in vivo X-ray computed tomography imaging.

    PubMed

    Kim, Dongkyu; Park, Sangjin; Lee, Jae Hyuk; Jeong, Yong Yeon; Jon, Sangyong

    2007-06-20

    Current computed tomography (CT) contrast agents such as iodine-based compounds have several limitations, including short imaging times due to rapid renal clearance, renal toxicity, and vascular permeation. Here, we describe a new CT contrast agent based on gold nanoparticles (GNPs) that overcomes these limitations. Because gold has a higher atomic number and X-ray absorption coefficient than iodine, we expected that GNPs can be used as CT contrast agents. We prepared uniform GNPs ( approximately 30 nm in diameter) by general reduction of HAuCl4 by boiling with sodium citrate. The resulting GNPs were coated with polyethylene glycol (PEG) to impart antibiofouling properties, which extends their lifetime in the bloodstream. Measurement of the X-ray absorption coefficient in vitro revealed that the attenuation of PEG-coated GNPs is 5.7 times higher than that of the current iodine-based CT contrast agent, Ultravist. Furthermore, when injected intravenously into rats, the PEG-coated GNPs had a much longer blood circulation time (>4 h) than Ultravist (<10 min). Consequently, CT images of rats using PEG-coated GNPs showed a clear delineation of cardiac ventricles and great vessels. On the other hand, relatively high levels of GNPs accumulated in the spleen and liver, which contain phagocytic cells. Intravenous injection of PEG-coated GNPs into hepatoma-bearing rats resulted in a high contrast ( approximately 2-fold) between hepatoma and normal liver tissue on CT images. These results suggest that PEG-coated GNPs can be useful as a CT contrast agent for a blood pool and hepatoma imaging.

  9. Implementation of a 3D mixing layer code on parallel computers

    NASA Technical Reports Server (NTRS)

    Roe, K.; Thakur, R.; Dang, T.; Bogucz, E.

    1995-01-01

    This paper summarizes our progress and experience in the development of a Computational-Fluid-Dynamics code on parallel computers to simulate three-dimensional spatially-developing mixing layers. In this initial study, the three-dimensional time-dependent Euler equations are solved using a finite-volume explicit time-marching algorithm. The code was first programmed in Fortran 77 for sequential computers. The code was then converted for use on parallel computers using the conventional message-passing technique, while we have not been able to compile the code with the present version of HPF compilers.

  10. Computed tomographic venography for varicose veins of the lower extremities: prospective comparison of 80-kVp and conventional 120-kVp protocols.

    PubMed

    Cho, Eun-Suk; Kim, Joo Hee; Kim, Sungjun; Yu, Jeong-Sik; Chung, Jae-Joon; Yoon, Choon-Sik; Lee, Hyeon-Kyeong; Lee, Kyung Hee

    2012-01-01

    To prospectively investigate the feasibility of an 80-kilovolt (peak) (kVp) protocol in computed tomographic venography for varicose veins of the lower extremities by comparison with conventional 120-kVp protocol. Attenuation values and signal-to-noise ratio of iodine contrast medium (CM) were determined in a water phantom for 2 tube voltages (80 kVp and 120 kVp). Among 100 patients, 50 patients were scanned with 120 kVp and 150 effective milliampere second (mAs(eff)), and the other 50 patients were scanned with 80 kVp and 390 mAs(eff) after the administration of 1.7-mL/kg CM (370 mg of iodine per milliliter). The 2 groups were compared for venous attenuation, contrast-to-noise ratio, and subjective degree of venous enhancement, image noise, and overall diagnostic image quality. In the phantom, the attenuation value and signal-to-noise ratio value for iodine CM at 80 kVp were 63.8% and 33.0% higher, respectively, than those obtained at 120 kVp. The mean attenuation of the measured veins of the lower extremities was 148.3 Hounsfield units (HU) for the 80-kVp protocol and 94.8 HU for the 120-kVp protocol. Contrast-to-noise ratio was also significantly higher with the 80-kVp protocol. The overall diagnostic image quality of the 3-dimensional volume-rendered images was good with both protocols. The subjective score for venous enhancement was higher at the 80-kVp protocol. The mean volume computed tomography dose index of the 80-kVp (5.6 mGy) protocol was 23.3% lower than that of the 120-kVp (7.3 mGy) protocol. The use of the 80-kVp protocol improved overall venous attenuation, especially in perforating vein, and provided similarly high diagnostic image quality with a lower radiation dose when compared to the conventional 120-kVp protocol.

  11. Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage.

    PubMed

    Watanabe, Yoshiyuki; Tsukabe, Akio; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tanaka, Hisashi; Yoshiya, Kazuhisa; Shimazu, Takeshi; Tomiyama, Noriyuki

    2014-04-01

    Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement. Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas. Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively. DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.

  12. Global iodine nutrition: Where do we stand in 2013?

    PubMed

    Pearce, Elizabeth N; Andersson, Maria; Zimmermann, Michael B

    2013-05-01

    Dietary iodine intake is required for the production of thyroid hormone. Consequences of iodine deficiency include goiter, intellectual impairments, growth retardation, neonatal hypothyroidism, and increased pregnancy loss and infant mortality. In 1990, the United Nations World Summit for Children established the goal of eliminating iodine deficiency worldwide. Considerable progress has since been achieved, largely through programs of universal salt iodization. Approximately 70% of all households worldwide currently have access to adequately iodized salt. In 2013, as defined by a national or subnational median urinary iodine concentration of 100-299 μg/L in school-aged children, 111 countries have sufficient iodine intake. Thirty countries remain iodine-deficient; 9 are moderately deficient, 21 are mildly deficient, and none are currently considered severely iodine-deficient. Ten countries have excessive iodine intake. In North America, both the United States and Canada are generally iodine-sufficient, although recent data suggest pregnant U.S. women are mildly iodine-deficient. Emerging issues include discrepancies between urinary iodine status in pregnant women compared to school-aged children in some populations, the problem of re-emerging iodine deficiency in parts of the developed world, the importance of food industry use of iodized salt, regions of iodine excess, and the potential effects of initiatives to lower population sodium consumption on iodine intake. Although substantial progress has been made over the last several decades, iodine deficiency remains a significant health problem worldwide and affects both industrialized and developing nations. The ongoing monitoring of population iodine status remains crucially important, and particular attention may need to be paid to monitoring the status of vulnerable populations, such as pregnant women and infants. There is also need for ongoing monitoring of iodized salt and other dietary iodine sources in order to prevent excess as well as insufficient iodine nutrition. Finally, it will be essential to coordinate interventions designed to reduce population sodium intake with salt iodization programs in order to maintain adequate levels of iodine nutrition as salt intake declines.

  13. Ab initio studies of ultrafast x-ray scattering of the photodissociation of iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debnarova, Andrea; Techert, Simone; Schmatz, Stefan

    2010-09-28

    We computationally examine various aspects of the reaction dynamics of the photodissociation and recombination of molecular iodine. We use our recently proposed formalism to calculate time-dependent x-ray scattering signal changes from first principles. Different aspects of the dynamics of this prototypical reaction are studied, such as coherent and noncoherent processes, features of structural relaxation that are periodic in time versus nonperiodic dissociative processes, as well as small electron density changes caused by electronic excitation, all with respect to x-ray scattering. We can demonstrate that wide-angle x-ray scattering offers a possibility to study the changes in electron densities in nonperiodic systems,more » which render it a suitable technique for the investigation of chemical reactions from a structural dynamics point of view.« less

  14. [Clinical application of iodine 123 with special consideration of radionuclide purity, measuring accuracy and radiation dose(author's dose)].

    PubMed

    Hermann, H J; Ammon, J; Winkel, K z; Haubold, U

    1975-05-01

    Iodine 123 is a nearly "ideal" radionuclide for thyroid imaging. The production of Iodine 123 requires cyclotrons or accelerators. The production of multicurie amounts of Iodine 123 has been suggested through the use of high-energy accelerators (less than 60 MeV). Most of the methods for the production of Iodine 123 using a compact cyclotron result in contamination with f.e. Iodine 124 which reduces the spatial resolution af imagining procedures and increases the radiation dose to the patient. The radiation dose has been calculated for three methods of production. The various contamination with Iodine 124, Iodine 125, and Iodine 126 result in comparable radiation dose of Iodine 131, provided that the time between production and application is more than four half-live-times of Iodine 123.

  15. 40 CFR 194.23 - Models and computer codes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  16. 40 CFR 194.23 - Models and computer codes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  17. 40 CFR 194.23 - Models and computer codes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  18. 40 CFR 194.23 - Models and computer codes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  19. 40 CFR 194.23 - Models and computer codes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Models and computer codes. 194.23... General Requirements § 194.23 Models and computer codes. (a) Any compliance application shall include: (1... obtain stable solutions; (iv) Computer models accurately implement the numerical models; i.e., computer...

  20. Iodine chemistry in the water column of the Chesapeake Bay: Evidence for organic iodine forms

    NASA Astrophysics Data System (ADS)

    Luther, George W.; Ferdelman, Timothy; Culberson, Charles H.; Kostka, Joel; Wu, Jingfeng

    1991-03-01

    During the summer of 1987, we collected and analysed Chesapeake Bay water samples for the inorganic iodine species: iodide (by cathodic-stripping squarewave voltammetry) and iodate (by differential pulse polarography); and total iodine (by hypochlorite oxidation of the seawater sample to iodate). The difference between the sum of the inorganic iodine species and the total iodine was significant for about one-third of the samples collected from the Bay. Thus, in these samples, a third (or more) 'new' form(s) of iodine was present. These samples were primarily from oxygen-saturated surface waters of high biological activity (primary productivity and bacterial processes). This 'new' form can make up as much as 70% of the total iodine. Waters containing low oxygen concentrations showed less of this 'new' form of iodine whereas anoxic and sulphidic bottom waters contained only iodide. This 'new' form of iodine is organic in nature and probably non-volatile. It may reside in the peptide and humic fractions. Only reduced iodine (iodide and organic iodine) was detected in waters from the northern section of the Bay, whereas only iodide and iodate were detected in the southern section of the Bay. In only two samples were iodide, iodate and the 'new' form of iodine found to coexist. Iodide and organic iodine are probably cycled in the surface waters of the northern section of the Bay via a combination of biogeochemical and photochemical processes which produce the reactive intermediates, molecular iodine and hypoiodous acid. These react quickly with reduced inorganic and organic compounds to maintain the reduced forms of iodine in the water column. Only total iodine is conservative throughout the estuary. The inorganic iodine forms can be used as geochemical tracers.

  1. Determination of iodide, iodate and organo-iodine in waters with a new total organic iodine measurement approach.

    PubMed

    Gong, Tingting; Zhang, Xiangru

    2013-11-01

    The dissolved iodine species that dominate aquatic systems are iodide, iodate and organo-iodine. These species may undergo transformation to one another and thus affect the formation of iodinated disinfection byproducts during disinfection of drinking waters or wastewater effluents. In this study, a fast, sensitive and accurate method for determining these iodine species in waters was developed by derivatizing iodide and iodate to organic iodine and measuring organic iodine with a total organic iodine (TOI) measurement approach. Within this method, organo-iodine was determined directly by TOI measurement; iodide was oxidized by monochloramine to hypoiodous acid and then hypoiodous acid reacted with phenol to form organic iodine, which was determined by TOI measurement; iodate was reduced by ascorbic acid to iodide and then determined as iodide. The quantitation limit of organo-iodine or sum of organo-iodine and iodide or sum of organo-iodine, iodide and iodate was 5 μg/L as I for a 40 mL water sample (or 2.5 μg/L as I for an 80 mL water sample, or 1.25 μg/L as I for a 160 mL water sample). This method was successfully applied to the determination of iodide, iodate and organo-iodine in a variety of water samples, including tap water, seawater, urine and wastewater. The recoveries of iodide, iodate and organo-iodine were 91-109%, 90-108% and 91-108%, respectively. The concentrations and distributions of iodine species in different water samples were obtained and compared. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Variable iodine intake persists in the context of universal salt iodization in China.

    PubMed

    Wu, Yongning; Li, Xiaowei; Chang, Suying; Liu, Liping; Zou, Shurong; Hipgrave, David Barry

    2012-09-01

    Iodine deficiency disorders were prevalent in China until the introduction of universal salt iodization in 1995. Concerns have recently arisen about possible excess iodine intake in this context. To document iodine intake and the contribution from iodized salt in China, we surveyed dietary iodine intake during China's nationally representative 2007 total diet study (TDS) and during an additional TDS in 4 coastal provinces and Beijing in 2009. Iodine intake was broken down by age and sex in 2009. Mean daily iodine and salt intake and the contribution from different food and beverage groups (and in 2009, individual items) was measured. The iodine in food cooked with iodized and noniodized salt was also assessed. The mean calculated iodine intake of a standard male in China was 425 μg/d in 2007 and 325 μg/d in coastal areas in 2009, well below the upper limit (UL) in all provinces. In 2009, iodine intake was above the UL in only 1-7% of age-sex groups, except among children (18-19%). A concerning number of individuals consumed less than the WHO-recommended daily allowance, including 31.5% of adult women. Salt contributed 63.5% of food iodine, and 24.6% of salt iodine was lost in cooking. Overall salt consumption declined between the surveys. Salt iodization assures iodine nutrition in China where environmental iodine is widely lacking. The risk of iodine excess is low, but planned decreases in salt iodization levels may increase the existing risk of inadequate intake. Regular monitoring of urinary iodine and more research on the impact of excess iodine intake is recommended.

  3. [Urinary iodine levels and its influencing factors among residents over age of 15 years in Shenzhen City].

    PubMed

    Luo, Yiqi; Xu, Jian; He, Shan; Wang, Jun; Fang, Xiaoheng

    2014-11-01

    To understand the status of iodine nutrition and the affective factors of urinary iodine concentration among residents over age of 15 years in Shenzhen City. Totally 8152 residents from 73 communities were selected with stratified cluster random sampling. The morning urinary iodine was determined and the dietary assessment of iodine using a food frequency questionnaire were carried out. The range of urinary iodine was 9. 65 - 4039.09 μg/L and the median of urinary iodine was 194.59 μg/L among the residents. The percentages of the residents with urinary iodine < 50,50 - 100,100 - 199, 200 - 300, and ≥ 300 μg/L were 2.49%, 12.12%, 40.16%, 26.94% and 20.78%, respectively. There was significant difference in the medians of iodine between different gender (P = 0.0001), the medians of urinary iodine of men (201.32 μg/L) was slightly higher. There was no significant difference in urinary iodine levels (186.59 - 197.44 μg/L) among all age groups, the medians of urinary iodine of all age groups were within the recommended adequate intake. Along with the increase in age, the medians of urinary iodine of all age groups was gradually decreased. Sex, alcohol consumption and daily dietary iodine intake was significant in the final regression model. The iodine nutrition of residents in Shenzhen City was in good condition, populations with low or high iodine still exist. The monitoring is needed and the influencing factors of the urine iodine levels need much exploration.

  4. [Field study on the change of urinary iodine levels among family members with iodine content of 5 - 150 microg/L in drinking water before and after non-iodized salt intervention].

    PubMed

    Li, Su-mei; Zhang, Gen-hong; Sun, Fan; Wang, Pei-hua; Zhang, Zhi-zhong; Li, Xiu-wei; Li, Shu-hua

    2008-08-01

    To compare the changes of urinary iodine levels among the family members with iodine content of 5 - 150 microg/L in drinking water, before and after non-iodized salt intervention through a field trail study. Family members who routinely drank water with iodine content 5 - 150 microg/L were chosen to substitute non-iodized salt for their current iodized salt for 2 months, and urine samples of the family members were collected for determination of iodine change before and after intervention was carried out. Median urinary iodine of school children, women with productive age and male adults exceeding 370 microg/L before intervention and the frequency distribution of urinary iodine were all above 70%. Our results revealed that iodine excess exited in three groups of family members. After intervention, all median urinary iodine level seemed to have decreased significantly, and groups with drinking water iodine 5.0 - 99.9 microg/L reduced to adequate or close to adequate while the group that drinking water iodine was 100 - 150 microg/L reached the cut-off point of excessive iodine level (300 microg/L). Results from your study posed the idea that the iodine adequate areas should be defined as the areas with iodine content of 5.0 - 100 microg/L in drinking water, and edible salt not be iodized in these areas. Areas with iodine content of 100 - 150 microg/L in drinking water should be classified as iodine excessive.

  5. Thyrotoxicosis induced by iodine contamination of food--a common unrecognised condition?

    PubMed Central

    Stewart, J C; Vidor, G I

    1976-01-01

    The incidence of thyrotoxicosis in northern Tasmania rose significantly in 1964, two years before an epidemic of iodine-induced thyrotoxicosis was precipitated by the addition of iodate to bread to prevent goitre. Each time older patients accounted for most of the increase. The 1964 increase was probably iodine-induced as the use of iodophor disinfectants on dairy farms, which causes iodine residues in milk, began in 1963 and a fall in the prevalence of goitre in young children suggested an increase in dietary iodine at about that time. A further small increase in thyrotoxicosis in 1971 may also have been iodine-induced as it followed an extension of the use of iodophors. Dietary iodine is rising substantially in many places because of high iodine levels in milk and the use of iodine compounds in automated bread making, and this may be causing unsuspected iodine-induced thyrotoxicosis. Dietary iodine should be monitored regularly and clinicans alerted to any rise. Contamination of common foods with iodine should be more strictly controlled. PMID:946162

  6. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    PubMed

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy of the noniodinated image is decreased and the breast-entrance air kerma is evenly distributed between both acquisitions. Predicted limits, in terms of iodine concentration, are found to guarantee the visualization of common clinical angiogenic concentrations in the breast.

  7. Urinary iodine concentration identifies pregnant women as iodine deficient yet school-aged children as iodine sufficient in rural Niger.

    PubMed

    Hess, Sonja Y; Ouédraogo, Césaire T; Young, Rebecca R; Bamba, Ibrahim F; Stinca, Sara; Zimmermann, Michael B; Wessells, K Ryan

    2017-05-01

    To assess iodine status among pregnant women in rural Zinder, Niger and to compare their status with the iodine status of school-aged children from the same households. Seventy-three villages in the catchment area of sixteen health centres were randomly selected to participate in the cross-sectional survey. Salt iodization is mandatory in Niger, requiring 20-60 ppm iodine at the retail level. A spot urine sample was collected from randomly selected pregnant women (n 662) and one school-aged child from the same household (n 373). Urinary iodine concentration (UIC) was assessed as an indicator of iodine status in both groups. Dried blood spots (DBS) were collected from venous blood samples of pregnant women and thyroglobulin (Tg), thyroid-stimulating hormone and total thyroxine were measured. Iodine content of household salt samples (n 108) was assessed by titration. Median iodine content of salt samples was 5·5 ppm (range 0-41 ppm), 98 % had an iodine content 40 µg/l. In this region of Niger, most salt is inadequately iodized. UIC in pregnant women indicated iodine deficiency, whereas UIC of school-aged children indicated marginally adequate iodine status. Thus, estimating population iodine status based solely on monitoring of UIC among school-aged children may underestimate the risk of iodine deficiency in pregnant women.

  8. Iodine deficiency and thyroid disorders.

    PubMed

    Zimmermann, Michael B; Boelaert, Kristien

    2015-04-01

    Iodine deficiency early in life impairs cognition and growth, but iodine status is also a key determinant of thyroid disorders in adults. Severe iodine deficiency causes goitre and hypothyroidism because, despite an increase in thyroid activity to maximise iodine uptake and recycling in this setting, iodine concentrations are still too low to enable production of thyroid hormone. In mild-to-moderate iodine deficiency, increased thyroid activity can compensate for low iodine intake and maintain euthyroidism in most individuals, but at a price: chronic thyroid stimulation results in an increase in the prevalence of toxic nodular goitre and hyperthyroidism in populations. This high prevalence of nodular autonomy usually results in a further increase in the prevalence of hyperthyroidism if iodine intake is subsequently increased by salt iodisation. However, this increase is transient because iodine sufficiency normalises thyroid activity which, in the long term, reduces nodular autonomy. Increased iodine intake in an iodine-deficient population is associated with a small increase in the prevalence of subclinical hypothyroidism and thyroid autoimmunity; whether these increases are also transient is unclear. Variations in population iodine intake do not affect risk for Graves' disease or thyroid cancer, but correction of iodine deficiency might shift thyroid cancer subtypes toward less malignant forms. Thus, optimisation of population iodine intake is an important component of preventive health care to reduce the prevalence of thyroid disorders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Iodine

    MedlinePlus

    ... the uterus (endometritis). Washing the vagina with a solution containing iodine in the form of povidone-iodine ... infection (periodontitis). Research suggests that rinsing with a solution containing iodine in the form of povidone-iodine ...

  10. Geographical distribution of drinking-water with high iodine level and association between high iodine level in drinking-water and goitre: a Chinese national investigation.

    PubMed

    Shen, Hongmei; Liu, Shoujun; Sun, Dianjun; Zhang, Shubin; Su, Xiaohui; Shen, Yanfeng; Han, Hepeng

    2011-07-01

    Excessive iodine intake can cause thyroid function disorders as can be caused by iodine deficiency. There are many people residing in areas with high iodine levels in drinking-water in China. The main aim of the present study was to map the geographical distribution of drinking-water with high iodine level in China and to determine the relationship between high iodine level in drinking-water and goitre prevalence. Iodine in drinking-water was measured in 1978 towns of eleven provinces in China, with a total of 28,857 water samples. We randomly selected children of 8-10 years old, examined the presence of goitre and measured their urinary iodine in 299 towns of nine provinces. Of the 1978 towns studied, 488 had iodine levels between 150 and 300 μg/l in drinking-water, and in 246 towns, the iodine level was >300 μg/l. These towns are mainly distributed along the original Yellow River flood areas, the second largest river in China. Of the 56 751 children examined, goitre prevalence was 6.3 % in the areas with drinking-water iodine levels of 150-300 μg/l and 11.0 % in the areas with drinking-water iodine >300 μg/l. Goitre prevalence increased with water and urinary iodine levels. For children with urinary iodine >1500 μg/l, goitre prevalence was 3.69 times higher than that for those with urinary iodine levels of 100-199 μg/l. The present study suggests that drinking-water with high iodine levels is distributed in eleven provinces of China. Goitre becomes more prevalent with the increase in iodine level in drinking-water. Therefore, it becomes important to prevent goitre through stopping the provision of iodised salt and providing normal drinking-water iodine through pipelines in these areas in China.

  11. Method for gettering organic, inorganic and elemental iodine in aqueous solutions

    DOEpatents

    Beahm, Edward C.; Shockley, William E.

    1990-07-03

    A process for the removal of iodine from aqueous solutions, particularly the trapping of radioactive iodine to mitigate damage resulting from accidents or spills associated with nuclear reactors, by exposing the solution to well dispersed silver carbonate which reacts with the iodine and iodides, thereby gettering iodine and iodine compounds from solution. The iodine is not only removed from solution but also from the contiguous vapor.

  12. Method for gettering organic, inorganic and elemental iodine in aqueous solutions

    DOEpatents

    Beahm, Edward C.; Shockley, William E.

    1990-01-01

    A process for the removal of iodine from aqueous solutions, particularly the trapping of radioactive iodine to mitigate damage resulting from accidents or spills associated with nuclear reactors, by exposing the solution to well dispersed silver carbonate which reacts with the iodine and iodides, thereby gettering iodine and iodine compounds from solution. The iodine is not only removed from solution but also from the contiguous vapor.

  13. Focus on nutrition: the role of iodine in nutrition and metabolism.

    PubMed

    Zicker, Steve; Schoenherr, Bill

    2012-10-01

    Iodine, which forms part of thyroid hormone, is essential for sustaining life in vertebrate animals. An absolute iodine requirement is difficult to determine because of adaptive responses to varying iodine intake. Excess or deficient iodine intake may result in altered thyroid metabolism. The magnitude and direction of the response to changes in dietary intake may also depend on previous iodine intake. Therefore, an understanding of the distribution, absorption, and metabolic fate of iodine is integral to the investigation of the role of iodine in disease states.

  14. Knowledge about Iodine in Pregnant and Lactating Women in the Oslo Area, Norway.

    PubMed

    Garnweidner-Holme, Lisa; Aakre, Inger; Lilleengen, Anne Marie; Brantsæter, Anne Lise; Henjum, Sigrun

    2017-05-13

    Lack of knowledge about iodine may be a risk factor for iodine deficiency in pregnant and lactating women. The aim of this study was to assess knowledge about iodine and predictors of iodine knowledge scores among pregnant and lactating women. The study also examined whether iodine knowledge scores were associated with iodine status. A cross-sectional study was performed on 804 pregnant women and 175 lactating women from 18 to 44 years of age in 2016 in the Oslo area, Norway. Knowledge about iodine was collected through a self-administered, paper-based questionnaire. Iodine concentrations in urine and breast milk were measured using an inductively coupled plasma mass spectrometer (ICPMS). 74% of the pregnant women and 55% of the lactating women achieved none to low iodine knowledge scores. Higher educated pregnant women and those who had received information about iodine had significantly higher knowledge scores. In lactating women, increased age was associated with higher knowledge scores. Knowledge scores were not associated with participants' iodine status. This study revealed a lack of knowledge about the importance of iodine in pregnant and lactating women, as well as about the most important dietary sources. Public education initiatives are required to increase the awareness about iodine in these population groups.

  15. Age and speciation of iodine in groundwater and mudstones of the Horonobe area, Hokkaido, Japan: Implications for the origin and migration of iodine during basin evolution

    NASA Astrophysics Data System (ADS)

    Togo, Yoko S.; Takahashi, Yoshio; Amano, Yuki; Matsuzaki, Hiroyuki; Suzuki, Yohey; Terada, Yasuko; Muramatsu, Yasuyuki; Ito, Kazumasa; Iwatsuki, Teruki

    2016-10-01

    This paper reports the concentration, speciation and isotope ratio (129I/127I) of iodine from both groundwater and host rocks in the Horonobe area, northern Hokkaido, Japan, to clarify the origin and migration of iodine in sedimentary rocks. Cretaceous to Quaternary sedimentary rocks deposited nearly horizontally in Tenpoku Basin and in the Horonobe area were uplifted above sea level during active tectonics to form folds and faults in the Quaternary. Samples were collected from the Pliocene Koetoi and late Miocene Wakkanai formations (Fms), which include diatomaceous and siliceous mudstones. The iodine concentration in groundwater, up to 270 μmol/L, is significantly higher than that of seawater, with the iodine enrichment factor relative to seawater reaching 800-1500. The iodine concentration in the rocks decreases from the Koetoi to Wakkanai Fms, suggesting that iodine was released into the water from the rocks of deeper formations. The iodine concentration in the rocks is sufficiently high for forming iodine-rich groundwater as found in this area. X-ray absorption near edge structure (XANES) analysis shows that iodine exists as organic iodine and iodide (I-) in host rocks, whereas it exists mainly as I- in groundwater. The isotope ratio is nearly constant for iodine in the groundwater, at [0.11-0.23] × 10-12, and it is higher for iodine in rocks, at [0.29-1.1] × 10-12, giving iodine ages of 42-60 Ma and 7-38 Ma, respectively. Some iodine in groundwater must have originated from Paleogene and even late Cretaceous Fms, which are also considered as possible sources of oil and gas, in view of the old iodine ages of the groundwater. The iodine ages of the rocks are older than the depositional ages, implying that the rocks adsorbed some iodine from groundwater, which was sourced from greater depths. The iodine concentration in groundwater decreases with decreasing chlorine concentration due to mixing of iodine-rich connate water and meteoric water. A likely scenario is that iodine-rich brine formed during the long-term basin evolution from the Cretaceous to Quaternary and that this brine was diluted by mixing with meteoric water during uplifting and denudation of the area.

  16. Long-term migration of iodine in sedimentary rocks based on iodine speciation and 129I/127I ratio

    NASA Astrophysics Data System (ADS)

    Togo, Y.; Takahashi, Y.; Amano, Y.; Matsuzaki, H.; Suzuki, Y.; Muramatsu, Y.; Iwatsuki, T.

    2012-12-01

    [Introduction] 129I is one of the available indexes of long-term migration of groundwater solutes, because of its long half-life (15.7 million years) and low sorption characteristics. The Horonobe underground research center (Japan Atomic Energy Agency), at which are conducted research and development of fundamental techniques on geological disposal of high-level radioactive waste, is an appropriate site for natural analogue studies, because iodine concentration in groundwater is high in this area. To predict iodine behavior in natural systems, speciation of iodine is essential because of different mobility among each species. In this study, we determined iodine speciation and129I/127I isotope ratios of rock and groundwater samples to investigate long term migration of iodine. [Methods] All rock and groundwater samples were collected at Horonobe underground research center. The region is underlain mainly by Neogene to Quaternary marine sedimentary rocks, the Wakkanai Formation (Wk Fm, siliceous mudstones), and the overlying Koetoi Formation (Kt Fm, diatomaceous mudstones). Iodine species in rock samples were determined by iodine K-edge X-ray absorption near edge structure (SPring-8 BL01B1). Thin sections of rock samples were prepared, and iodine mapping were obtained by micro-XRF analysis (SPring-8 BL37XU). Iodine species (IO3-, I-, and organic I) in groundwater were separately detected by high performance liquid chromatography connected to ICP-MS. The 129I/127I ratios in groundwater and rock samples were measured by accelerator mass spectrometry (MALT, Univ. of Tokyo). Iodine in rock samples were separated by pyrohydrolysis and water extraction. [Results and discussion] Concentration of iodine in groundwater varied widely and was much higher than that of seawater showing a high correlation with that of chlorine (R2 = 0.90). Species of iodine in groundwater was mainly I-. Iodine in rock samples decreased near the boundary between Wk and Kt Fms. Iodine K-edge XANES showed that iodine in rock was a mixture of organic and inorganic iodine. According to iodine and carbon mapping in micrometer scale, iodine was accumulated locally and correlated with carbon, suggesting that iodine existed as organic iodine. The 129I/127I isotope ratios in groundwater were lower than those in rocks and almost constant at various depths, demonstrating that iodine in groundwater was released from layers deeper than co-existing rocks. According to these results, migration of iodine in this area can be expected as follows. (i) During sedimentation of Wk and Kt Fms, iodine was accumulated as organic iodine in siliceous sediments. (ii) Iodine was released as I- from the layers deeper than Wk Fm during diagenetic processes. Subsequently, iodine rich groundwater was distributed to Wk and Kt Fms due to the compaction of the layers. (iii) During uplift and denudation processes, both iodine and chlorine were diluted by meteoric water from the surface. Iodine distribution coefficient (Kd = [I concentration in rock]/[I concentration in groundwater]) of Kt Fm is higher than that in Wk Fm. Diatomaceous mudstones might be more effective than siliceous mudstones as natural barrier for 129I released from deep underground radioactive waste repository. This suggestion should be reinforced by laboratory experiments in future studies.

  17. Computer Description of Black Hawk Helicopter

    DTIC Science & Technology

    1979-06-01

    Model Combinatorial Geometry Models Black Hawk Helicopter Helicopter GIFT Computer Code Geometric Description of Targets 20. ABSTRACT...description was made using the technique of combinatorial geometry (COM-GEOM) and will be used as input to the GIFT computer code which generates Tliic...rnHp The data used bv the COVART comtmter code was eenerated bv the Geometric Information for Targets ( GIFT )Z computer code. This report documents

  18. Incidence of intravenous contrast extravasation: increased risk for patients with deep brachial catheter placement from the emergency department.

    PubMed

    Hardie, Andrew D; Kereshi, Borko

    2014-06-01

    Deep brachial intravenous catheter (IV) placement can be performed in emergency department patients with difficult vascular access, but the safety of deep brachial IV for iodinated contrast administration has not been assessed. This study compares the relative risk for extravasation of deep brachial IV compared with antecubital IV during power injected computed tomography (CT) examinations. A departmental practice quality improvement was performed to assess the rate of IV extravasation for all CT examinations during a 1 year period. De-identified data was analyzed with a waiver of informed consent to identify the rate and relative risk of iodinated contrast extravasation by catheter type. A total of 10,750 injections were performed, with 82 extravasation events (0.8 %). There were 51 extravasations of antecubital IV from approximately 8,599 placed (0.6 %). For 123 deep brachial IV placed, there were eight extravasations (6.5 %). The relative risk of a deep brachial IV extravasation was 9.4 compared to 0.4 for antecubital placement. Deep brachial IV demonstrated a markedly higher rate of contrast extravasation than antecubital IV. For power injected iodinated contrast administration, it is recommended to avoid the use of deep brachial IV whenever possible.

  19. Acceptability of oral iodinated contrast media: a head-to-head comparison of four media.

    PubMed

    Pollentine, A; Ngan-Soo, E; McCoubrie, P

    2013-05-01

    To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml(-1) dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Gastrografin is rated significantly less palatable than the remaining media (p<0.005). Omnipaque and Telebrix are significantly more palatable than Gastromiro. No difference existed between Omnipaque and Telebrix. 39% of participants would refuse to consume the quantities of Gastrografin required for a CTC examination compared with Telebrix (7%) and Omnipaque (9%) (p<0.05). Omnipaque and Telebrix are significantly more palatable than both Gastromiro and Gastrografin, with participants more willing to ingest them in larger quantities as well as being less expensive. Omnipaque and Telebrix are significantly more palatable iodinated oral contrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC.

  20. Acceptability of oral iodinated contrast media: a head-to-head comparison of four media

    PubMed Central

    Ngan-Soo, E; McCoubrie, P

    2013-01-01

    Objective: To assess the palatability of iodinated oral contrast media commonly used in abdominopelvic CT and CT colonography (CTC). Methods: 80 volunteers assessed the palatability of a 20-ml sample of a standard 30 mg ml−1 dilution of Omnipaque® (iohexol; GE Healthcare, Cork, Ireland), Telebrix® (meglumine ioxithalamate; Guerbet, Aulnay-sous-Bois, France), Gastromiro® (iopamidol; Bracco, High Wycombe, UK) and Gastrografin® (sodium diatrizoate and meglumine diatrizoate; Bayer, Newbury, UK) in a computer-generated random order. Results: Gastrografin is rated significantly less palatable than the remaining media (p<0.005). Omnipaque and Telebrix are significantly more palatable than Gastromiro. No difference existed between Omnipaque and Telebrix. 39% of participants would refuse to consume the quantities of Gastrografin required for a CTC examination compared with Telebrix (7%) and Omnipaque (9%) (p<0.05). Conclusion: Omnipaque and Telebrix are significantly more palatable than both Gastromiro and Gastrografin, with participants more willing to ingest them in larger quantities as well as being less expensive. Advances in knowledge: Omnipaque and Telebrix are significantly more palatable iodinated oral contrast media than both Gastromiro and Gastrografin, which has potential implications in compliance with both abdominopelvic CT and CTC. PMID:23564884

  1. Iodine concentration of milk-alternative drinks available in the UK in comparison to cows’ milk

    PubMed Central

    Bath, Sarah C.; Hill, Sarah; Infante, Heidi Goenaga; Elghul, Sarah; Nezianya, Carolina J.; Rayman, Margaret P.

    2017-01-01

    Iodine deficiency is present in certain groups of the UK population, notably in pregnant women; this is of concern as iodine is required for fetal brain development. UK milk is rich in iodine and is the principal dietary iodine source. UK sales of milk-alternative drinks are increasing but data are lacking on their iodine content. As consumers may replace iodine-rich milk with milk-alternative drinks, we aimed to measure the iodine concentration of those available in the UK. Using ICP-MS, we determined the iodine concentration of seven types of milk-alternative drink (soya, almond, coconut, oat, rice, hazelnut, and hemp) by analysing 47 products purchased in November/December 2015. For comparison, winter samples of conventional (n=5) and organic (n=5) cows’ milk were included. The median iodine concentration of all of the unfortified milk-alternative drinks (n=44) was low, at 7.3 μg/kg, just 1.7% of our value for winter conventional cows’ milk (median 438 μg/kg). One brand (not the market leader), fortified its soya, oat, and rice drinks with iodine and those drinks had a higher iodine concentration than unfortified drinks, at 280, 287, 266 μg/kg respectively. The iodine concentration of organic milk (median 324 μg/kg) was lower than that of conventional milk. Although many milk-alternative drinks are fortified with calcium, at the time of this study, just three of 47 drinks were fortified with iodine. Individuals who consume milk-alternative drinks that are not fortified with iodine in place of cows’ milk may be at risk of iodine deficiency unless they consume alternative dietary iodine sources. PMID:28946925

  2. Iodine concentration of milk-alternative drinks available in the UK in comparison with cows' milk.

    PubMed

    Bath, Sarah C; Hill, Sarah; Infante, Heidi Goenaga; Elghul, Sarah; Nezianya, Carolina J; Rayman, Margaret P

    2017-10-01

    Iodine deficiency is present in certain groups of the UK population, notably in pregnant women; this is of concern as iodine is required for fetal brain development. UK milk is rich in iodine and is the principal dietary iodine source. UK sales of milk-alternative drinks are increasing but data are lacking on their iodine content. As consumers may replace iodine-rich milk with milk-alternative drinks, we aimed to measure the iodine concentration of those available in the UK. Using inductively coupled plasma-MS, we determined the iodine concentration of seven types of milk-alternative drink (soya, almond, coconut, oat, rice, hazelnut and hemp) by analysing forty-seven products purchased in November/December 2015. For comparison, winter samples of conventional (n 5) and organic (n 5) cows' milk were included. The median iodine concentration of all of the unfortified milk-alternative drinks (n 44) was low, at 7·3 μg/kg, just 1·7 % of our value for winter conventional cows' milk (median 438 μg/kg). One brand (not the market leader), fortified its soya, oat and rice drinks with iodine and those drinks had a higher iodine concentration than unfortified drinks, at 280, 287 and 266 μg/kg, respectively. The iodine concentration of organic milk (median 324 μg/kg) was lower than that of conventional milk. Although many milk-alternative drinks are fortified with Ca, at the time of this study, just three of forty-seven drinks were fortified with iodine. Individuals who consume milk-alternative drinks that are not fortified with iodine in place of cows' milk may be at risk of iodine deficiency unless they consume alternative dietary iodine sources.

  3. The Standard, Intervention Measures and Health Risk for High Water Iodine Areas

    PubMed Central

    Liu, Peng; Liu, Lixiang; Shen, Hongmei; Jia, Qingzhen; Wang, Jinbiao; Zheng, Heming; Ma, Jing; Zhou, Dan; Liu, Shoujun; Su, Xiaohui

    2014-01-01

    Our study aims to clarify the population nutrient status in locations with different levels of iodine in the water in China; to choose effective measurements of water improvement(finding other drinking water source of iodine not excess) or non-iodised salt supply or combinations thereof; to classify the areas of elevated water iodine levels and the areas with endemic goiter; and to evaluate the risk factors of water iodine excess on pregnant women, lactating women and the overall population of women. From Henan, Hebei, Shandong and Shanxi province of China, for each of 50∼99 µg/L, 100∼149 µg/L, 150∼299 µg/L, and ≥300 µg/L water iodine level, three villages were selected respectively. Students of 6–12 years old and pregnant were sampled from villages of each water-iodine level of each province, excluded iodized salt consumer. Then the children's goiter volume, the children and pregnant's urinary iodine and water iodine were tested. In addition, blood samples were collected from pregnant women, lactating women and other women of reproductive age for each water iodine level in the Shanxi Province for thyroid function tests. These indicators should be matched for each person. When the water iodine exceeds 100 µg/L; the iodine nutrient of children are iodine excessive, and are adequate or more than adequate for the pregnant women. It is reasonable to define elevated water iodine areas as locations where the water iodine levels exceed 100 µg/L. The supply of non-iodised salt alone cannot ensure adequate iodine nutrition of the residents, and water improvement must be adopted, as well. Iodine excess increases the risk of certain thyroid diseases in women from one- to eightfold. PMID:24586909

  4. The standard, intervention measures and health risk for high water iodine areas.

    PubMed

    Liu, Peng; Liu, Lixiang; Shen, Hongmei; Jia, Qingzhen; Wang, Jinbiao; Zheng, Heming; Ma, Jing; Zhou, Dan; Liu, Shoujun; Su, Xiaohui

    2014-01-01

    Our study aims to clarify the population nutrient status in locations with different levels of iodine in the water in China; to choose effective measurements of water improvement(finding other drinking water source of iodine not excess) or non-iodised salt supply or combinations thereof; to classify the areas of elevated water iodine levels and the areas with endemic goiter; and to evaluate the risk factors of water iodine excess on pregnant women, lactating women and the overall population of women. From Henan, Hebei, Shandong and Shanxi province of China, for each of 50 ∼ 99 µg/L, 100 ∼ 149 µg/L, 150 ∼ 299 µg/L, and ≥ 300 µg/L water iodine level, three villages were selected respectively. Students of 6-12 years old and pregnant were sampled from villages of each water-iodine level of each province, excluded iodized salt consumer. Then the children's goiter volume, the children and pregnant's urinary iodine and water iodine were tested. In addition, blood samples were collected from pregnant women, lactating women and other women of reproductive age for each water iodine level in the Shanxi Province for thyroid function tests. These indicators should be matched for each person. When the water iodine exceeds 100 µg/L; the iodine nutrient of children are iodine excessive, and are adequate or more than adequate for the pregnant women. It is reasonable to define elevated water iodine areas as locations where the water iodine levels exceed 100 µg/L. The supply of non-iodised salt alone cannot ensure adequate iodine nutrition of the residents, and water improvement must be adopted, as well. Iodine excess increases the risk of certain thyroid diseases in women from one- to eightfold.

  5. The Iodine Content in Urine, Faeces and Selected Organs of Rats Fed Lettuce Biofortified with Iodine Through Foliar Application.

    PubMed

    Rakoczy, Roksana; Kopeć, Aneta; Piątkowska, Ewa; Smoleń, Sylwester; Skoczylas, Łukasz; Leszczyńska, Teresa; Sady, Włodzimierz

    2016-12-01

    Iodine is an essential trace element for humans. Foliar application of micronutrients is successfully used in order to increase the concentration of essential elements in vegetables. The aim of this study was to evaluate the iodine absorption in the rat organism fed foliar biofortified lettuce. The presented study was consisted of the vegetative and animal experiment. In the vegetative experiment with lettuce, two combinations of foliar application were used: (1) control-without iodine application and (2) iodine application in the potassium iodide (KI) form. In the animal experiment, Wistar rats were divided to four groups, which received one of four diets: (1) C-control diet containing iodine in the KI form, (2) D-diet deficient in iodine, (3) D + BL-diet containing biofortified lettuce, and (4) D + CL-diet containing control lettuce (as the only source of iodine in diet, respectively). The diets contained 0.260, 0.060, 0.254 and 0.075 mg I/kg, respectively. In order to determine the iodine absorption in the rat organisms, the content of this trace element was measured in urine, faeces and in selected organs with the use of the ICP-OES technique. Foliar application of the KI increased the content of iodine in lettuce. The rats from the D + BL group excreted significantly less iodine in their urine and faeces and also accumulated more iodine in the organs than the rats from the C group. Iodine with biofortified lettuce was much bioavailable for rodents than iodine from control diet. Biofortified lettuce can be a source of iodine in a diet of human and can improve iodine nutrition.

  6. Metathetical Redox Reaction of (Diacetoxyiodo)arenes and Iodoarenes.

    PubMed

    Jobin-Des Lauriers, Antoine; Legault, Claude Y

    2015-12-17

    The oxidation of iodoarenes is central to the field of hypervalent iodine chemistry. It was found that the metathetical redox reaction between (diacetoxyiodo)arenes and iodoarenes is possible in the presence of a catalytic amount of Lewis acid. This discovery opens a new strategy to access (diacetoxyiodo)arenes. A computational study is provided to rationalize the results observed.

  7. The role of iodine in human growth and development.

    PubMed

    Zimmermann, Michael B

    2011-08-01

    Iodine is an essential component of the hormones produced by the thyroid gland. Thyroid hormones, and therefore iodine, are essential for mammalian life. Iodine deficiency is a major public health problem; globally, it is estimated that two billion individuals have an insufficient iodine intake. Although goiter is the most visible sequelae of iodine deficiency, the major impact of hypothyroidism due to iodine deficiency is impaired neurodevelopment, particularly early in life. In the fetal brain, inadequate thyroid hormone impairs myelination, cell migration, differentiation and maturation. Moderate-to-severe iodine deficiency during pregnancy increases rates of spontaneous abortion, reduces birth weight, and increases infant mortality. Offspring of deficient mothers are at high risk for cognitive disability, with cretinism being the most severe manifestation. It remains unclear if development of the offspring is affected by mild maternal iodine deficiency. Moderate-to-severe iodine deficiency during childhood reduces somatic growth. Correction of mild-to-moderate iodine deficiency in primary school aged children improves cognitive and motor function. Iodine prophylaxis of deficient populations with periodic monitoring is an extremely cost effective approach to reduce the substantial adverse effects of iodine deficiency throughout the life cycle. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. 40 CFR 415.430 - Applicability; description of the iodine production subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... iodine production subcategory. 415.430 Section 415.430 Protection of Environment ENVIRONMENTAL PROTECTION... CATEGORY Iodine Production Subcategory § 415.430 Applicability; description of the iodine production... iodine. ...

  9. 40 CFR 415.430 - Applicability; description of the iodine production subcategory.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... iodine production subcategory. 415.430 Section 415.430 Protection of Environment ENVIRONMENTAL PROTECTION... CATEGORY Iodine Production Subcategory § 415.430 Applicability; description of the iodine production... iodine. ...

  10. Investigation of iodine concentration in salt, water and soil along the coast of Zhejiang, China*

    PubMed Central

    Lu, Ying-li; Wang, Ning-jian; Zhu, Lan; Wang, Guo-xing; Wu, Hui; Kuang, Lin; Zhu, Wen-ming

    2005-01-01

    Objective: We aim to describe the environment iodine concentration in salt, water and soil along Zhejiang Province coast in the China foreland. It will be helpful for us to judge whether this area is insufficient in iodine and universal iodized salt is necessary or not. Methods: We collected iodized salt samples, drinking water samples (tap water in the towns, and well water or spring water in the villages), water samples from different sources (ditches, lakes, rivers) and soil samples through random sampling in June, 2005. Salt, water and soil iodine was detected by arsenic-cerium redox method. Statistical analysis was expressed as mean±SEM by Windows SPSS 13.0. Results: (1) The iodine concentration in salt was 27.9±4.33 mg/kg (n=108). (2) Seventy-five water samples were collected. The water iodine value was 0.6~84.8 μg/L (mean of 11.66 μg/L). The watershed along the Qiantang River has significantly higher iodine content than the water in Lin’an in mountain area (P<0.01). The iodine content and mean iodine content of tap water, well or spring water and natural water sources were 4.30±2.43 μg/L (n=34), 23.59±27.74 μg/L (n=19) and 12.72±10.72 μg/L (n=22) respectively. This indicated that among environmental water sources, the ditch iodine content was the highest with river water iodine being the lowest (P<0.01). (3) Soil iodine value was 0.11~2.93 mg/kg (mean of 1.32 mg/kg). Though there was no statistical difference of soil iodine in different districts (P=0.131), soil iodine content correlated positively with water iodine content. Conclusion: Iodine concentration in salt accords with national policy of adding iodine in salt. Foreland has more iodine in water than mountain area. The data reflected that water and soil iodine in foreland area was not high, which suggests universal iodized salt should be necessary. Environment iodine has relatively close association with pollution. PMID:16358379

  11. Breast-Milk Iodine Concentrations and Iodine Levels of Infants According to the Iodine Status of the Country of Residence: A Systematic Review and Meta-Analysis.

    PubMed

    Nazeri, Pantea; Kabir, Ali; Dalili, Hosein; Mirmiran, Parvin; Azizi, Fereidoun

    2018-01-01

    Iodine, an essential micronutrient, plays a critical role in normal growth and development, especially during the first two years of life. This systematic review and meta-analysis is among the first to evaluate breast-milk iodine concentrations and infant iodine status in countries characterized by iodine sufficiency or deficiency. PubMed, Web of Science, Cochrane Library, Google Scholar, and other relevant databases, as well as reference lists of previous reviews, were searched for relevant studies published between 1986 and 2016. Mean or median breast-milk and infant urinary iodine concentrations, along with other relevant data, were extracted from eligible studies. Each study was assessed for quality and risk of bias. Of the 496 identified studies, 57 met the criteria for inclusion in the meta-analysis. The mean (confidence interval [CI]) iodine concentrations in maternal colostrum were 152.0 μg/L [CI 106.2-198.7 μg/L] and 57.8 μg/L [CI 41.4-74.1 μg/L] in iodine-sufficient and -deficient countries, respectively, indicating a significant difference between the two iodine statuses. By contrast, the corresponding values in mature milk did not differ significantly between mothers in iodine-sufficient and -deficient countries (71.5 μg/L [CI 51.0-92.0 μg/L] and 28.0 μg/L [CI -13.8 to 69.9 μg/L], respectively]. The weighted urinary iodine levels [CIs] of breast-fed infants in iodine-sufficient countries were significantly higher than those in iodine-deficient countries (164.5 μg/L [CI 116.4-212.7 μg/L] vs. 70.4 μg/L [CI 46.2-94.6 μg/L]). Similarly, a significant difference was observed in the pooled estimates of urinary iodine levels [CIs] among formula-fed infants in iodine-sufficient versus iodine-deficient countries (310.3 μg/L [CI 287.4-342.1 μg/L] vs. 38.3 μg/L [CI 23.4-53.2 μg/L]). The meta-analysis reveals that in iodine-sufficient countries, the mean iodine concentrations in colostrum and mature breast milk corresponded to iodine sufficiency among infants. The results are thus compatible with the international recommendation that lactating women and infants younger than two years of age who reside in iodine-sufficient countries do not require iodine supplementation.

  12. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  13. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  14. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Iodine-126 1 Iodine-129 0.1 Iodine-131 1 Iodine-132 10 Iodine-133 1 Iodine-134 10 Iodine-135 10 Iridium... Arsenic-73 100 Arsenic-74 10 Arsenic-76 10 Arsenic-77 100 Barium-131 10 Barium-133 10 Barium-140 10... Carbon-14 100 Cerium-141 100 Cerium-143 100 Cerium-144 1 Cesium-131 1,000 Cesium-134m 100 Cesium-134 1...

  15. Computed Tomography Imaging of Solid Tumors Using a Liposomal-Iodine Contrast Agent in Companion Dogs with Naturally Occurring Cancer

    PubMed Central

    Ghaghada, Ketan B.; Sato, Amy F.; Starosolski, Zbigniew A.; Berg, John; Vail, David M.

    2016-01-01

    Objectives Companion dogs with naturally occurring cancer serve as an important large animal model in translational research because they share strong similarities with human cancers. In this study, we investigated a long circulating liposomal-iodine contrast agent (Liposomal-I) for computed tomography (CT) imaging of solid tumors in companion dogs with naturally occurring cancer. Materials and Methods The institutional animal ethics committees approved the study and written informed consent was obtained from all owners. Thirteen dogs (mean age 10.1 years) with a variety of masses including primary and metastatic liver tumors, sarcomas, mammary carcinoma and lung tumors, were enrolled in the study. CT imaging was performed pre-contrast and at 15 minutes and 24 hours after intravenous administration of Liposomal-I (275 mg/kg iodine dose). Conventional contrast-enhanced CT imaging was performed in a subset of dogs, 90 minutes prior to administration of Liposomal-I. Histologic or cytologic diagnosis was obtained for each dog prior to admission into the study. Results Liposomal-I resulted in significant (p < 0.05) enhancement and uniform opacification of the vascular compartment. Non-renal, reticulo-endothelial systemic clearance of the contrast agent was demonstrated. Liposomal-I enabled visualization of primary and metastatic liver tumors. Sub-cm sized liver lesions grossly appeared as hypo-enhanced compared to the surrounding normal parenchyma with improved lesion conspicuity in the post-24 hour scan. Large liver tumors (> 1 cm) demonstrated a heterogeneous pattern of intra-tumoral signal with visibly higher signal enhancement at the post-24 hour time point. Extra-hepatic, extra-splenic tumors, including histiocytic sarcoma, anaplastic sarcoma, mammary carcinoma and lung tumors, were visualized with a heterogeneous enhancement pattern in the post-24 hour scan. Conclusions The long circulating liposomal-iodine contrast agent enabled prolonged visualization of small and large tumors in companion dogs with naturally occurring cancer. The study warrants future work to assess the sensitivity and specificity of the Liposomal-I agent in various types of naturally occurring canine tumors. PMID:27031614

  16. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    NASA Astrophysics Data System (ADS)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p < 0.05). The enhancement was evaluated based on a consensus of four observers. The enhancement pattern and the morphological features during the arterial and the delayed phases were correlated between the Gd-EOB-DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p < 0.05). For the preoperative detection of focal liver lesions, Gd-EOB-DTPA-enhanced MRI had a higher diagnostic value and higher detection rate than iodine-enhanced MDCT. The arterial and the delayed dynamic enhancement patterns, and the gadoxetic-acid-enhanced MR imaging can provide information on the possible degree of cellular differentiation of a HCC, adenoma or metastatic tumor.

  17. Assessing iodine intake, iodine status, and the effects of maternal iodine supplementation: introduction to articles arising from 3 workshops held by the NIH Office of Dietary Supplements12

    PubMed Central

    Ershow, Abby G; Coates, Paul M; Swanson, Christine A

    2016-01-01

    The NIH Office of Dietary Supplements (ODS) convened 3 workshops on iodine nutrition in 2014, each held in Rockville, Maryland. These workshops were part of the ongoing ODS Iodine Initiative, begun in 2011 in response to concerns that US pregnant women may be at risk of iodine deficiency and that a high fraction of prenatal dietary supplements do not contain the recommended amounts of iodine. The primary purpose of the workshops was to consider the data and resources necessary to evaluate the clinical and public health benefits and risks of maternal iodine supplementation in the United States. The first workshop focused on the assessment of iodine intake, the second focused on the assessment of iodine status, and the third focused on the design and interpretation of clinical trials of maternal iodine supplementation. Here we provide the background of the ODS Iodine Initiative, summarize the 3 workshops held in 2014, and introduce the articles that arose from the workshops and are published in this supplement issue. PMID:27534646

  18. Assessing iodine intake, iodine status, and the effects of maternal iodine supplementation: introduction to articles arising from 3 workshops held by the NIH Office of Dietary Supplements.

    PubMed

    Ershow, Abby G; Goodman, Gay; Coates, Paul M; Swanson, Christine A

    2016-09-01

    The NIH Office of Dietary Supplements (ODS) convened 3 workshops on iodine nutrition in 2014, each held in Rockville, Maryland. These workshops were part of the ongoing ODS Iodine Initiative, begun in 2011 in response to concerns that US pregnant women may be at risk of iodine deficiency and that a high fraction of prenatal dietary supplements do not contain the recommended amounts of iodine. The primary purpose of the workshops was to consider the data and resources necessary to evaluate the clinical and public health benefits and risks of maternal iodine supplementation in the United States. The first workshop focused on the assessment of iodine intake, the second focused on the assessment of iodine status, and the third focused on the design and interpretation of clinical trials of maternal iodine supplementation. Here we provide the background of the ODS Iodine Initiative, summarize the 3 workshops held in 2014, and introduce the articles that arose from the workshops and are published in this supplement issue. © 2016 American Society for Nutrition.

  19. User manual for semi-circular compact range reflector code: Version 2

    NASA Technical Reports Server (NTRS)

    Gupta, Inder J.; Burnside, Walter D.

    1987-01-01

    A computer code has been developed at the Ohio State University ElectroScience Laboratory to analyze a semi-circular paraboloidal reflector with or without a rolled edge at the top and a skirt at the bottom. The code can be used to compute the total near field of the reflector or its individual components at a given distance from the center of the paraboloid. The code computes the fields along a radial, horizontal, vertical or axial cut at that distance. Thus, it is very effective in computing the size of the sweet spot for a semi-circular compact range reflector. This report describes the operation of the code. Various input and output statements are explained. Some results obtained using the computer code are presented to illustrate the code's capability as well as being samples of input/output sets.

  20. Capacity and degree of iodine absorbed and enriched by vegetable from soil.

    PubMed

    Weng, Huan-Xin; Weng, Jing-Ke; Yong, Wen-Bin; Sun, Xiang-Wu; Zhong, Hang

    2003-01-01

    To understand the biogeochemical transfer of iodine, the absorbability and bioaccumulation of iodine in tested vegetables (radish, spinach and Chinese cabbage) are examined by applying iodic fertilizer composed of kelp and diatomaceous earth. The experimental results show that when iodine in soil is not excessive, the concentrations of iodine in tested vegetables increase as the content of iodine in soil increases. The absorbability and enrichment degree of iodine in various vegetables and in various parts of the same vegetable a redifferent, which explains that the concentration of iodine in plant is determined by the plant type and the physiological action of plant. The patience order of tested vegetables to excessive iodine is Chinese cabbage > spinach > radish. These results have theoretical and practical significance in opening up a new way for ameliorating poor iodine environment with artificial means.

  1. [A cross-sectional study on iodine nutrition in general population from Zhejiang province, China].

    PubMed

    Mo, Zhe; Lou, Xiao-ming; Zhu, Wen-ming; Wang, Xiao-feng; Mao, Guang-ming; Zhou, Jin-shui; Ding, Gang-qiang

    2013-05-01

    To understand the current status of iodine nutrition among the community residents to compare the level of iodine nutrition in different areas and groups of populations in Zhejiang province. Stratified cluster sampling method was adopted and residents from twenty-two communities in Zhejiang province were selected. A cross-sectional survey was conducted, using questionnaires, laboratory tests, on urinary iodine, water iodine and the concentration of the iodine in salt, which had played positive roles in the calculation of the level of iodine nutrition. of the iodine nutrition in this cross-sectional survey were as follows: the median water iodine and salt iodine of Zhejiang were 2.42 µg/L and 28.8 mg/kg, respectively. The coverage of iodized salts was 79.54%, with the ingesting rate of qualified iodized-salt as 76.65% and the median content of urinary iodine in the population of Zhejiang was 161 µg/L. The average iodine content among pregnant women was 138 µg/L, with the percentage of samples less than 100 µg/L as 25.92%, more than 300 µg/L as 15.30%. The proportions of iodine intake through water, salt and other foods were 1.70%, 76.41% and 21.89%, respectively. The status of iodine nutrition in Zhejiang province in general seemed to be appropriate, but the level of iodine nutrition in pregnant women was less than the requirement, which should call for attention.

  2. Determining median urinary iodine concentration that indicates adequate iodine intake at population level.

    PubMed Central

    Delange, François; de Benoist, Bruno; Burgi, Hans

    2002-01-01

    OBJECTIVE: Urinary iodine concentration is the prime indicator of nutritional iodine status and is used to evaluate population-based iodine supplementation. In 1994, WHO, UNICEF and ICCIDD recommended median urinary iodine concentrations for populations of 100- 200 micro g/l, assuming the 100 micro g/l threshold would limit concentrations <50 micro g/l to 100 micro g/l. The total population was 55 892, including 35 661 (64%) schoolchildren. Median urinary iodine concentrations were 111-540 (median 201) micro g/l for all populations, 100-199 micro g/l in 23 (48%) populations and >/=200 micro g/l in 25 (52%). The frequencies of values <50 micro g/l were 0-20.8 (mean 4.8%) overall and 7.2% and 2.5% in populations with medians of 100-199 micro g/l and >200 micro g/l, respectively. The frequency reached 20% only in two places where iodine had been supplemented for <2 years. CONCLUSION: The frequency of urinary iodine concentrations <50 micro g/l in populations with median urinary iodine concentrations >/=100 micro g/l has been overestimated. The threshold of 100 micro g/l does not need to be increased. In populations, median urinary iodine concentrations of 100-200 micro g/l indicate adequate iodine intake and optimal iodine nutrition. PMID:12219154

  3. Iodine deficiency in pregnant women living in the South East of the UK: the influence of diet and nutritional supplements on iodine status.

    PubMed

    Bath, Sarah C; Walter, Alan; Taylor, Andrew; Wright, John; Rayman, Margaret P

    2014-05-01

    Iodine is a key component of the thyroid hormones which are crucial for brain development. Adequate intake of iodine in pregnancy is important as in utero deficiency may have lifelong consequences for the offspring. Data on the iodine status of UK pregnant women are sparse, and there are no such data for pregnant women in the South East of the UK. A total of 100 pregnant women were recruited to a cross-sectional study carried out at the Royal Surrey County Hospital, Guildford, at their first-trimester visit for an ultrasound scan. The participants provided a spot-urine sample (for the measurement of urinary iodine concentration (UIC) and creatinine concentration) and 24 h iodine excretion was estimated from the urinary iodine:creatinine ratio. Women completed a general questionnaire and a FFQ. The median UIC (85·3 μg/l) indicated that the group was iodine deficient by World Health Organisation criteria. The median values of the iodine:creatinine ratio (122·9 μg/g) and of the estimated 24 h iodine excretion (151·2 μg/d) were also suggestive of iodine deficiency. UIC was significantly higher in women taking an iodine-containing prenatal supplement (n 42) than in those not taking such a supplement (P< 0·001). In the adjusted analyses, milk intake, maternal age and iodine-containing prenatal supplement use were positively associated with the estimated 24 h urinary iodine excretion. Our finding of iodine deficiency in these women gives cause for concern. We suggest that women of childbearing age and pregnant women should be given advice on how to improve their iodine status through dietary means. A national survey of iodine status in UK pregnant women is required.

  4. Iodine nutrition status in lactating mothers residing in countries with mandatory and voluntary iodine fortification programs: an updated systematic review.

    PubMed

    Nazeri, Pantea; Mirmiran, Parvin; Shiva, Niloofar; Mehrabi, Yadollah; Mojarrad, Mehdi; Azizi, Fereidoun

    2015-06-01

    The aim of this review is to assess data available on iodine nutrition status in lactating mothers residing in countries with mandatory and voluntary iodine fortification programs and/or iodine supplementation. A systematic review was conducted by searching articles published between 1964 and 2013 in Pub Med, ISI Web, and Cochrane Library using iodine nutrition, lactation, iodine supplementation, and iodine fortification as keywords for titles and/or abstracts. Relevant articles were included if they reported urinary iodine concentration (UIC) in lactating mothers and, if determined, the type of iodine fortification program and/or iodine supplementation. Forty-two studies met the inclusion criteria. Among these, 21 studies assessed lactating mothers in countries with a mandatory iodine fortification program, 17 studies were from countries with voluntary and/or without iodine fortification programs, and four studies assessed iodine nutrition status in lactating mothers undergoing iodine supplementation. Among countries with mandatory iodine fortification programs, the range of salt iodization level in lactating mothers with a UIC <100 μg/L was between 8 and 40 ppm, whereas among lactating mothers with UIC >100 μg/L, it was between 15 and 60 ppm. Levels of UIC <100 μg/L were observed among lactating women in India, Denmark, Mali, New Zealand, Australia, Slovakia, Sudan, and Turkey, whereas in countries such as Chile, Iran, Mongolia, New Guinea, and Nigeria, the median or mean of UIC was >100 μg/L. There was a median or mean UIC <100 μg/L in nearly all lactating mothers residing in countries where implementation of universal salt iodization program was voluntary, including Switzerland, Australia, New Zealand, Ireland, and Germany. However, in some countries with voluntary iodine fortification programs, such as the United States, Spain, and Japan, a mean or median UIC of >100 μg/L has been reported. Although universal salt iodization is still the most feasible and cost-effective approach for iodine deficiency control in pregnant and lactating mothers, UIC in lactating mothers of most countries with voluntary programs and in areas with mandatory iodine fortification is still within the iodine deficiency range, indicating that iodine supplementation in daily prenatal vitamin/mineral supplements in lactating mothers is warranted. However, further investigations are still recommended in this regard.

  5. Hanford meteorological station computer codes: Volume 9, The quality assurance computer codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burk, K.W.; Andrews, G.L.

    1989-02-01

    The Hanford Meteorological Station (HMS) was established in 1944 on the Hanford Site to collect and archive meteorological data and provide weather forecasts and related services for Hanford Site approximately 1/2 mile east of the 200 West Area and is operated by PNL for the US Department of Energy. Meteorological data are collected from various sensors and equipment located on and off the Hanford Site. These data are stored in data bases on the Digital Equipment Corporation (DEC) VAX 11/750 at the HMS (hereafter referred to as the HMS computer). Files from those data bases are routinely transferred to themore » Emergency Management System (EMS) computer at the Unified Dose Assessment Center (UDAC). To ensure the quality and integrity of the HMS data, a set of Quality Assurance (QA) computer codes has been written. The codes will be routinely used by the HMS system manager or the data base custodian. The QA codes provide detailed output files that will be used in correcting erroneous data. The following sections in this volume describe the implementation and operation of QA computer codes. The appendices contain detailed descriptions, flow charts, and source code listings of each computer code. 2 refs.« less

  6. Addition of chlorine during water purification reduces iodine content of drinking water and contributes to iodine deficiency.

    PubMed

    Samson, L; Czegeny, I; Mezosi, E; Erdei, A; Bodor, M; Cseke, B; Burman, K D; Nagy, E V

    2012-01-01

    Drinking water is the major natural source of iodine in many European countries. In the present study, we examined possible sites of iodine loss during the usual water purification process.Water samples from 6 sites during the technological process were taken and analyzed for iodine content. Under laboratory circumstances, prepared iodine in water solution has been used as a model to test the effect of the presence of chlorine. Samples from the purification sites revealed that in the presence of chlorine there is a progressive loss of iodine from the water. In the chlorine concentrations employed in the purification process, 24-h chlorine exposure eliminated more than 50% of iodine when the initial iodine concentration was 250 μg/l or less. Iodine was completely eliminated if the starting concentration was 16 μg/l.We conclude that chlorine used during water purification may be a major contributor to iodine deficiency in European communities.

  7. Consensus statement on iodine deficiency disorders in Hong Kong.

    PubMed

    But, Betty; Chan, C W; Chan, Fredriech; Chan, K W; Cheng, Anna W F; Cheung, Patrick; Choi, K L; Chow, C B; Chow, Francis C C; Eastman, Creswell; Fok, T F; Fung, L M; Gomes, Cynthia; Huen, K F; Ip, T P; Kung, Annie W C; Lam, Karen S L; Lam, Y Y; Lao, Terence; Lee, C Y; Lee, K F; Leung, Jenny; Leung, N K; Li, Dominic; Li, June; Lo, K W; Lo, Louis; Ng, K L; Siu, S C; Tam, Sidney; Tan, Kathryn C B; Tiu, S C; Tse, H Y; Tse, Winnie; Wong, Gary; Wong, Shell; Wong, William; Yeung, Vincent T F; Young, Rosie; Yu, C M; Yu, Richard

    2003-12-01

    This article reviews the available data on the study of iodine deficiency disorders in Hong Kong and to discuss the approach towards preventing such disorders in Hong Kong. The importance of iodine and iodine deficiency disorders is described, and the available data on the dietary iodine intake and urinary iodine concentration in different populations of Hong Kong are summarised and discussed. Dietary iodine insufficiency among pregnant women in Hong Kong is associated with maternal goitrogenesis and hypothyroxinaemia as well as neonatal hypothyroidism. Borderline iodine deficiency exists in the expectant mothers in Hong Kong. Women of reproductive age, and pregnant and lactating women should be made aware and educated to have an adequate iodine intake, such as iodised salt, as an interim measure. A steering group involving all stakeholders should be formed to advise on the strategy of ensuring adequate iodine intake, including universal iodisation of salt in Hong Kong. Continuous surveillance of iodine status in the Hong Kong population is necessary.

  8. Iodination and stability of somatostatin analogues: comparison of iodination techniques. A practical overview.

    PubMed

    de Blois, Erik; Chan, Ho Sze; Breeman, Wouter A P

    2012-01-01

    For iodination ((125/127)I) of tyrosine-containing peptides, chloramin-T, Pre-Coated Iodo-Gen(®) tubes and Iodo-Beads(®) (Pierce) are commonly used for in vitro radioligand investigations and there have been reliant vendors hereof for decades. However, commercial availability of these radio-iodinated peptides is decreasing. For continuation of our research in this field we investigated and optimized (radio-)iodination of somatostatin analogues. In literature, radioiodination using here described somatostatin analogues and iodination techniques are described separately. Here we present an overview, including High Performance Liquid Chromatography (HPLC) separation and characterisation by mass spectrometry, to obtain mono- and di-iodinated analogues. Reaction kinetics of (125/127)I iodinated somatostatin analogues were investigated as function of reaction time and concentration of reactants, including somatostatin analogues, iodine and oxidizing agent. To our knowledge, for the here described somatostatin analogues, no (127)I iodination and optimization are described. (Radio-)iodinated somatostatin analogues could be preserved with a >90% radiochemical purity for 1 month after reversed phase HPLC-purification.

  9. Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT.

    PubMed

    Leng, Shuai; Yu, Lifeng; Fletcher, Joel G; McCollough, Cynthia H

    2015-08-01

    To determine the iodine contrast-to-noise ratio (CNR) for abdominal computed tomography (CT) when using energy domain noise reduction and virtual monoenergetic dual-energy (DE) CT images and to compare the CNR to that attained with single-energy CT at 80, 100, 120, and 140 kV. This HIPAA-compliant study was approved by the institutional review board with waiver of informed consent. A syringe filled with diluted iodine contrast material was placed into 30-, 35-, and 45-cm-wide water phantoms and scanned with a dual-source CT scanner in both DE and single-energy modes with matched scanner output. Virtual monoenergetic images were generated, with energies ranging from 40 to 110 keV in 10-keV steps. A previously developed energy domain noise reduction algorithm was applied to reduce image noise by exploiting information redundancies in the energy domain. Image noise and iodine CNR were calculated. To show the potential clinical benefit of this technique, it was retrospectively applied to a clinical DE CT study of the liver in a 59-year-old male patient by using conventional and iterative reconstruction techniques. Image noise and CNR were compared for virtual monoenergetic images with and without energy domain noise reduction at each virtual monoenergetic energy (in kiloelectron volts) and phantom size by using a paired t test. CNR of virtual monoenergetic images was also compared with that of single-energy images acquired with 80, 100, 120, and 140 kV. Noise reduction of up to 59% (28.7 of 65.7) was achieved for DE virtual monoenergetic images by using an energy domain noise reduction technique. For the commercial virtual monoenergetic images, the maximum iodine CNR was achieved at 70 keV and was 18.6, 16.6, and 10.8 for the 30-, 35-, and 45-cm phantoms. After energy domain noise reduction, maximum iodine CNR was achieved at 40 keV and increased to 30.6, 25.4, and 16.5. These CNRs represented improvement of up to 64% (12.0 of 18.6) with the energy domain noise reduction technique. For single-energy CT at the optimal tube potential, iodine CNR was 29.1 (80 kV), 21.2 (80 kV), and 11.5 (100 kV). For patient images, 39% (24 of 61) noise reduction and 67% (0.74 of 1.10) CNR improvement were observed with the energy domain noise reduction technique when compared with standard filtered back-projection images. Iodine CNR for adult abdominal CT may be maximized with energy domain noise reduction and virtual monoenergetic DE CT. (©) RSNA, 2015.

  10. User's manual for semi-circular compact range reflector code

    NASA Technical Reports Server (NTRS)

    Gupta, Inder J.; Burnside, Walter D.

    1986-01-01

    A computer code was developed to analyze a semi-circular paraboloidal reflector antenna with a rolled edge at the top and a skirt at the bottom. The code can be used to compute the total near field of the antenna or its individual components at a given distance from the center of the paraboloid. Thus, it is very effective in computing the size of the sweet spot for RCS or antenna measurement. The operation of the code is described. Various input and output statements are explained. Some results obtained using the computer code are presented to illustrate the code's capability as well as being samples of input/output sets.

  11. The Iodine Status of Queensland Preschool Children After the Introduction of Mandatory Iodine Fortification in Bread: An Exploratory Study Using a Convenience Sample.

    PubMed

    Samidurai, A J; Ware, R S; Davies, P S W

    2017-01-01

    Introduction Appropriate dietary iodine is essential for thyroid hormone synthesis, especially in young children. Following an iodine fortification in bread initiative, approximately 6 % of Australian preschool children were expected to have an excessive iodine status. The aim of this study was to document the current iodine status of preschool children using urinary iodine concentration (UIC) as a biomarker of iodine intake. Methods A convenience sample of fifty-one preschool children, aged 2-3 years, were recruited from south east Queensland. UIC was ascertained from spot morning and afternoon urine samples collected on two consecutive days and food frequency questionnaires were completed for each participant. Dietary iodine intake was extrapolated from UIC assuming 90 % of dietary iodine is excreted in urine and a urine volume of 0.5 L/day. Results A median UIC of 223.3 μg/L was found. The calculated median dietary iodine intake was 124.8 μg/day (SD 47.0) with 9.8 % of samples above the upper level of 200 μg for dietary iodine for children within this age group. No foods were associated with UIC. Discussion Limited by sample size and recruitment strategies, no association was found between usual food intake and UIC. Extrapolated dietary iodine intake indicated that children within this cohort consumed adequate amounts of dietary iodine, although the number of children consuming above the upper limit of 300 μg/day was almost double of expected. The development of a UIC criteria to assess appropriate parameters for varying degrees of iodine status is required for the monitoring of iodine nutrition in this vulnerable age group.

  12. Longitudinal trends in thyroid function in relation to iodine intake: ongoing changes of thyroid function despite adequate current iodine status.

    PubMed

    van de Ven, Annenienke C; Netea-Maier, Romana T; Ross, H Alec; van Herwaarden, Teun A E; Holewijn, Suzanne; de Graaf, Jacqueline; Kiemeney, Bart L A; van Tienoven, Doorlène; Wetzels, Jack F M; Smit, Johannes W; Sweep, Fred C G J; Hermus, Ad R M M; den Heijer, Martin

    2014-01-01

    Several cross-sectional studies on populations with iodine deficiency showed that TSH-levels are negatively associated with age, while in populations with high iodine intake TSH is positively associated with age. The question is whether such an age-thyroid function relation is an ongoing process apparent also in longitudinal studies and whether it reflects an actual iodine deficiency or an iodine insufficiency in the past. In an area with a borderline iodine status in the past, we studied 980 participants of the Nijmegen Biomedical Study. We measured serum TSH, free thyroxine (FT₄), total triiodothyronine (T₃), peroxidase antibodies, and the urine iodine and creatinine concentration 4 years after our initial survey of thyroid function, in which we reported a negative association between TSH and age. within 4 years, TSH decreased by 5.4% (95% ci 2.58.3%) and FT₄ increased by 3.7% (95% ci 2.94.6%). median urinary iodine concentration was 130 μg/l. estimated 24-h iodine excretion was not associated with TSH, T₃, change of TSH, or FT₄ over time or with the presence of antibodies against thyroid peroxidase. Only FT₄ appeared to be somewhat higher at lower urine iodine levels: a 1.01% (95% CI 0.17-1.84%) higher FT₄ for each lower iodine quintile. In this longitudinal study, we found an ongoing decrease in TSH and increase in FT₄ in a previously iodine insufficient population, despite the adequate iodine status at present. This suggests that low iodine intake at young age leads to thyroid autonomy (and a tendency to hyperthyroidism) that persists despite normal iodine intake later in life.

  13. Low iodine content in the diets of hospitalized preterm infants.

    PubMed

    Belfort, Mandy B; Pearce, Elizabeth N; Braverman, Lewis E; He, Xuemei; Brown, Rosalind S

    2012-04-01

    Iodine is critical for normal thyroid hormone synthesis and brain development during infancy, and preterm infants are particularly vulnerable to the effects of both iodine deficiency and excess. Use of iodine-containing skin antiseptics in intensive care nurseries has declined substantially in recent years, but whether the current dietary iodine intake meets the requirement for hospitalized preterm infants is unknown. The aim of the study was to measure the iodine content of enteral and parenteral nutrition products commonly used for hospitalized preterm infants and estimate the daily iodine intake for a hypothetical 1-kg infant. We used mass spectrometry to measure the iodine concentration of seven preterm infant formulas, 10 samples of pooled donor human milk, two human milk fortifiers (HMF) and other enteral supplements, and a parenteral amino acid solution and soy-based lipid emulsion. We calculated the iodine provided by typical diets based on 150 ml/kg · d of formula, donor human milk with or without HMF, and parenteral nutrition. Preterm formula provided 16.4-28.5 μg/d of iodine, whereas unfortified donor human milk provided only 5.0-17.6 μg/d. Adding two servings (six packets) of Similac HMF to human milk increased iodine intake by 11.7 μg/d, whereas adding two servings of Enfamil HMF increased iodine intake by only 0.9 μg/d. The other enteral supplements contained almost no iodine, nor did a parenteral nutrition-based diet. Typical enteral diets for hospitalized preterm infants, particularly those based on donor human milk, provide less than the recommended 30 μg/d of iodine, and parenteral nutrition provides almost no iodine. Additional iodine fortification should be considered.

  14. Highly fault-tolerant parallel computation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spielman, D.A.

    We re-introduce the coded model of fault-tolerant computation in which the input and output of a computational device are treated as words in an error-correcting code. A computational device correctly computes a function in the coded model if its input and output, once decoded, are a valid input and output of the function. In the coded model, it is reasonable to hope to simulate all computational devices by devices whose size is greater by a constant factor but which are exponentially reliable even if each of their components can fail with some constant probability. We consider fine-grained parallel computations inmore » which each processor has a constant probability of producing the wrong output at each time step. We show that any parallel computation that runs for time t on w processors can be performed reliably on a faulty machine in the coded model using w log{sup O(l)} w processors and time t log{sup O(l)} w. The failure probability of the computation will be at most t {center_dot} exp(-w{sup 1/4}). The codes used to communicate with our fault-tolerant machines are generalized Reed-Solomon codes and can thus be encoded and decoded in O(n log{sup O(1)} n) sequential time and are independent of the machine they are used to communicate with. We also show how coded computation can be used to self-correct many linear functions in parallel with arbitrarily small overhead.« less

  15. Suboptimal Iodine Concentration in Breastmilk and Inadequate Iodine Intake among Lactating Women in Norway.

    PubMed

    Henjum, Sigrun; Lilleengen, Anne Marie; Aakre, Inger; Dudareva, Anna; Gjengedal, Elin Lovise Folven; Meltzer, Helle Margrete; Brantsæter, Anne Lise

    2017-06-22

    Breastfed infants depend on sufficient maternal iodine intake for optimal growth and neurological development. Despite this, few studies have assessed iodine concentrations in human milk and there is currently no published data on iodine status among lactating women in Norway. The aim of this study was to assess iodine concentrations in breast milk (BMIC) in lactating women and estimate iodine intake. Five Mother and Child Health Centres in Oslo were randomly selected during 2016, and 175 lactating women between 2nd and 28th weeks postpartum participated. Each of the women provided four breastmilk samples which were pooled and analysed for iodine concentrations. Participants also provided information on iodine intake from food and supplements covering the last 24 h and the habitual iodine intake (food frequency questionnaire). The median (p25, p75 percentiles) BMIC was 68 (45, 98) µg/L and 76% had BMIC <100 µg/L. Only 19% had taken an iodine-containing supplement during the last 24 h. The median 24 h iodine intake from food (p25, p75) was 121 (82, 162) µg/day and the total intake (food and supplements) was 134 (95, 222) µg/day. The majority of lactating women had suboptimal BMIC and inadequate intake of iodine from food and supplements.

  16. The importance of iodine nutrition during pregnancy.

    PubMed

    Glinoer, Daniel

    2007-12-01

    To examine the importance of iodine nutrition during pregnancy. Review of existing literature of iodine in pregnancy. Population surveys and metabolic studies. Pregnant women. The main changes in thyroid function associated with pregnancy are due to an increase in hormone requirements that begin in the first trimester of gestation. This increase can only be met by a proportional increase in hormone production, something that depends directly upon the availability of iodine. When dietary iodine is lacking, an adequate physiological adaptation is difficult to achieve and is progressively replaced by pathological alterations that occur in parallel with the degree and duration of iodine deprivation. Iodine prophylaxis should be given systematically to women during pregnancy. In most public health programmes dealing with the correction of iodine deficiency disorders, iodised salt has been used as the preferred means to deliver iodine to households. Iodised salt, however, is not the ideal means of delivering iodine in the specific instances of pregnancy, breast-feeding and complementary feeding because of the need to limit salt intake during these periods. In European countries, presently it is proposed that iodine is given to pregnant women and breast-feeding mothers by systematically administering multivitamin tablets containing iodine in order to reach the recommended dietary allowance of 250 microg iodine day-1.

  17. Suboptimal Iodine Concentration in Breastmilk and Inadequate Iodine Intake among Lactating Women in Norway

    PubMed Central

    Henjum, Sigrun; Lilleengen, Anne Marie; Aakre, Inger; Dudareva, Anna; Gjengedal, Elin Lovise Folven; Meltzer, Helle Margrete; Brantsæter, Anne Lise

    2017-01-01

    Breastfed infants depend on sufficient maternal iodine intake for optimal growth and neurological development. Despite this, few studies have assessed iodine concentrations in human milk and there is currently no published data on iodine status among lactating women in Norway. The aim of this study was to assess iodine concentrations in breast milk (BMIC) in lactating women and estimate iodine intake. Five Mother and Child Health Centres in Oslo were randomly selected during 2016, and 175 lactating women between 2nd and 28th weeks postpartum participated. Each of the women provided four breastmilk samples which were pooled and analysed for iodine concentrations. Participants also provided information on iodine intake from food and supplements covering the last 24 h and the habitual iodine intake (food frequency questionnaire). The median (p25, p75 percentiles) BMIC was 68 (45, 98) µg/L and 76% had BMIC <100 µg/L. Only 19% had taken an iodine-containing supplement during the last 24 h. The median 24 h iodine intake from food (p25, p75) was 121 (82, 162) µg/day and the total intake (food and supplements) was 134 (95, 222) µg/day. The majority of lactating women had suboptimal BMIC and inadequate intake of iodine from food and supplements. PMID:28640217

  18. Systematic review using meta-analyses to estimate dose-response relationships between iodine intake and biomarkers of iodine status in different population groups.

    PubMed

    Ristić-Medić, Danijela; Dullemeijer, Carla; Tepsić, Jasna; Petrović-Oggiano, Gordana; Popović, Tamara; Arsić, Aleksandra; Glibetić, Marija; Souverein, Olga W; Collings, Rachel; Cavelaars, Adriënne; de Groot, Lisette; van't Veer, Pieter; Gurinović, Mirjana

    2014-03-01

    The objective of this systematic review was to identify studies investigating iodine intake and biomarkers of iodine status, to assess the data of the selected studies, and to estimate dose-response relationships using meta-analysis. All randomized controlled trials, prospective cohort studies, nested case-control studies, and cross-sectional studies that supplied or measured dietary iodine and measured iodine biomarkers were included. The overall pooled regression coefficient (β) and the standard error of β were calculated by random-effects meta-analysis on a double-log scale, using the calculated intake-status regression coefficient (β) for each individual study. The results of pooled randomized controlled trials indicated that the doubling of dietary iodine intake increased urinary iodine concentrations by 14% in children and adolescents, by 57% in adults and the elderly, and by 81% in pregnant women. The dose-response relationship between iodine intake and biomarkers of iodine status indicated a 12% decrease in thyroid-stimulating hormone and a 31% decrease in thyroglobulin in pregnant women. The model of dose-response quantification used to describe the relationship between iodine intake and biomarkers of iodine status may be useful for providing complementary evidence to support recommendations for iodine intake in different population groups.

  19. Development of Standard Reference Materials to support assessment of iodine status for nutritional and public health purposes.

    PubMed

    Long, Stephen E; Catron, Brittany L; Boggs, Ashley Sp; Tai, Susan Sc; Wise, Stephen A

    2016-09-01

    The use of urinary iodine as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in urine. Likewise, the use of dietary iodine intake as an indicator of iodine status relies in part on the accuracy of the analytical measurement of iodine in dietary sources, including foods and dietary supplements. Similarly, the use of specific serum biomarkers of thyroid function to screen for both iodine deficiency and iodine excess relies in part on the accuracy of the analytical measurement of those biomarkers. The National Institute of Standards and Technology has been working with the NIH Office of Dietary Supplements for several years to develop higher-order reference measurement procedures and Standard Reference Materials to support the validation of new routine analytical methods for iodine in foods and dietary supplements, for urinary iodine, and for several serum biomarkers of thyroid function including thyroid-stimulating hormone, thyroglobulin, total and free thyroxine, and total and free triiodothyronine. These materials and methods have the potential to improve the assessment of iodine status and thyroid function in observational studies and clinical trials, thereby promoting public health efforts related to iodine nutrition. © 2016 American Society for Nutrition.

  20. An emulator for minimizing computer resources for finite element analysis

    NASA Technical Reports Server (NTRS)

    Melosh, R.; Utku, S.; Islam, M.; Salama, M.

    1984-01-01

    A computer code, SCOPE, has been developed for predicting the computer resources required for a given analysis code, computer hardware, and structural problem. The cost of running the code is a small fraction (about 3 percent) of the cost of performing the actual analysis. However, its accuracy in predicting the CPU and I/O resources depends intrinsically on the accuracy of calibration data that must be developed once for the computer hardware and the finite element analysis code of interest. Testing of the SCOPE code on the AMDAHL 470 V/8 computer and the ELAS finite element analysis program indicated small I/O errors (3.2 percent), larger CPU errors (17.8 percent), and negligible total errors (1.5 percent).

  1. Iodine-induced hyperthyroidism--an epidemiological survey several years after institution of iodine prophylaxis in Poland.

    PubMed

    Lewiński, A; Szybiński, Z; Bandurska-Stankiewicz, E; Grzywa, M; Karwowska, A; Kinalska, I; Kowalska, A; Makarewicz, J; Nauman, J; Słowińska-Klencka, D; Sowiński, J; Syrenicz, A; Zonenberg, A; Huszno, B; Klencki, M

    2003-01-01

    In 1997, the obligatory model of iodine prophylaxis was introduced in Poland in order to correct the existing status of mild and/or moderate iodine deficiency. In order to monitor possible side-effects of increased iodine supply, studies on iodine-induced hyperthyroidism were initiated by establishing several regional registers of hyperthyroidism. In the present paper, the results of a two-year monitoring (2000-2001) have been summarized. There are no epidemiological data on hyperthyroidism prior to starting the iodine prophylaxis, but the obtained current data are comparable to observations in other countries, made after iodine supplementation. The incidence of iodine-induced hyperthyroidism did not exceed the acceptable level, thus confirming--together with previous observations on the effectiveness of iodine prophylaxis--the adequacy of applied dose of KI (30 microg/kg NaCl), used for salt iodization in Poland.

  2. Effect of iodine disinfection products on higher plants

    NASA Technical Reports Server (NTRS)

    Janik, D.; Macler, B.; Macelroy, R. D.; Thorstenson, Y.; Sauer, R.

    1989-01-01

    Iodine is used to disinfect potable water on United States spacecraft. Iodinated potable water will likely be used to grow plants in space. Little is known about the effects of iodine disinfection products on plants. Seeds of select higher plants were germinated in water iodinated using the Shuttle Microbial Check Valve, and water to which measured amounts of iodine was added. Percent germination was decreased in seeds of most species germinated in iodinated water. Beans were most affected. Germination rates, determined from germination half-times, were decreased for beans germinated in iodinated water, and water to which iodide was added. Development was retarded and rootlets were conspicuously absent in bean and several other plant species germinated in iodinated water. Iodide alone did not elicit these responses. Clearly iodine disinfection products can affect higher plants. These effects must be carefully considered for plant experimentation and cultivation in space, and in design and testing of closed environmental life support systems.

  3. Effect of iodine disinfectant source and water quality parameters on soluble iodine speciation

    NASA Technical Reports Server (NTRS)

    Silverstein, Joann; Hurst, Charles; Barkley, Robert; Dunham, Andrew

    1993-01-01

    Investigations of iodine species distribution of various aqueous solutions of iodine disinfectants and water from equilibrated suspensions of triodide and pentaiodide resins were done at the University of Colorado for the Center for Space Environmental Health during 1992 and 1993. Direct measurements of three individual iodine species: I(-), I2 and I3(-), were made. In addition three measures of total titratable iodine species were used. It has been found that I2 and I3(-) solutions produce a significant fraction of the non-disinfecting species iodine I(-), ranging from 50 to 80% of added iodine, respectively, at pH values of approximately 5. Correspondingly, I2 solutions produce more than twice the concentration of disinfecting iodine species per mass iodine dose than I3(-) solutions. Both I(-) and I2 species were found in aqeuous extracts of pentaiodide resin, although no soluble species were detected with triiodide resin.

  4. The Effect of Povidone-Iodine (Betadine) on Serum Protein-Bound Iodine, When Used as a Surgical Preparation on Intact Skin

    PubMed Central

    Higgins, H. P.; Hawks, G. H.; O'Sullivan, M.; Shaw, M.

    1964-01-01

    A study was undertaken to determine whether the use of povidone-iodine (Betadine) as a skin disinfectant prior to surgery would affect the protein-bound iodine (PBI) and so invalidate this parameter of thyroid function. Ninety-seven consecutive patients were chosen who had no thyroid disease and who had not recently been exposed to iodine in any form. Their serum PBI levels were determined before and after a wide variety of surgical operations. Povidone-iodine was used as a skin disinfectant in the operating room in all cases. Care was taken to avoid contact of the povidone-iodine with the mucous membranes. No significant change in the protein-bound iodine could be detected and it was concluded that there could be no objection to the use of povidone-iodine on the ground of its possible effect on the protein-bound iodine. PMID:14158542

  5. High-Performance Water-Iodinating Cartridge

    NASA Technical Reports Server (NTRS)

    Sauer, Richard; Gibbons, Randall E.; Flanagan, David T.

    1993-01-01

    High-performance cartridge contains bed of crystalline iodine iodinates water to near saturation in single pass. Cartridge includes stainless-steel housing equipped with inlet and outlet for water. Bed of iodine crystals divided into layers by polytetrafluoroethylene baffles. Holes made in baffles and positioned to maximize length of flow path through layers of iodine crystals. Resulting concentration of iodine biocidal; suppresses growth of microbes in stored water or disinfects contaminated equipment. Cartridge resists corrosion and can be stored wet. Reused several times before necessary to refill with fresh iodine crystals.

  6. A generalized one-dimensional computer code for turbomachinery cooling passage flow calculations

    NASA Technical Reports Server (NTRS)

    Kumar, Ganesh N.; Roelke, Richard J.; Meitner, Peter L.

    1989-01-01

    A generalized one-dimensional computer code for analyzing the flow and heat transfer in the turbomachinery cooling passages was developed. This code is capable of handling rotating cooling passages with turbulators, 180 degree turns, pin fins, finned passages, by-pass flows, tip cap impingement flows, and flow branching. The code is an extension of a one-dimensional code developed by P. Meitner. In the subject code, correlations for both heat transfer coefficient and pressure loss computations were developed to model each of the above mentioned type of coolant passages. The code has the capability of independently computing the friction factor and heat transfer coefficient on each side of a rectangular passage. Either the mass flow at the inlet to the channel or the exit plane pressure can be specified. For a specified inlet total temperature, inlet total pressure, and exit static pressure, the code computers the flow rates through the main branch and the subbranches, flow through tip cap for impingement cooling, in addition to computing the coolant pressure, temperature, and heat transfer coefficient distribution in each coolant flow branch. Predictions from the subject code for both nonrotating and rotating passages agree well with experimental data. The code was used to analyze the cooling passage of a research cooled radial rotor.

  7. Iodine Excretion in 24-hour Urine Collection and Its Dietary Determinants in Healthy Japanese Adults

    PubMed Central

    Katagiri, Ryoko; Asakura, Keiko; Uechi, Ken; Masayasu, Shizuko; Sasaki, Satoshi

    2016-01-01

    Background Since seaweed is a common component of the Japanese diet, iodine intake in Japanese is expected to be high. However, urinary iodine excretion, measured using 24-hour urine samples, and its dietary determinants are not known. Methods Apparently healthy adults aged 20 to 69 years living in 20 areas throughout Japan were recruited in February and March, 2013. Urinary iodine excretion was evaluated using 24-hour urine collected from 713 subjects (362 men and 351 women), and the difference among age groups was assessed. The association between dietary intake of food groups and urinary iodine excretion was assessed among 358 subjects who completed a semi-weighed 4-day diet record (DR) and urine collection. The correlations between iodine intake and iodine excretion were also evaluated, and correlation coefficients were calculated for iodine intake in the DR of the overlapping day or the DR 1 day before and after urine collection. Results Median iodine excretion in 24-hour urine was 365 µg, and excretion was significantly higher in older subjects. Iodine intake estimated by the DRs was significantly correlated with urinary iodine excretion when DRs and urine collection were obtained on the same day (r = 0.37). After adjustment for confounding factors, iodine excretion was significantly associated with intakes of kelp and soup stock from kelp and fish. Conclusions Although multiple measurements for urinary iodine are required to confirm our results, this study showed the current iodine status of healthy Japanese adults. The results suggest that kelp and fish are the main contributors to Japanese iodine status measured by 24-hour urine. PMID:27374137

  8. Assessment of iodine nutritional status in the general population in the province of Jaén.

    PubMed

    Olmedo Carrillo, Pablo; García Fuentes, Eduardo; Gutiérrez Alcántara, Carmen; Serrano Quero, Manuel; Moreno Martínez, Macarena; Ureña Fernández, Tomás; Santiago Fernández, Piedad

    2015-10-01

    Iodine deficiency affecting both pregnant women and schoolchildren has been reported in Jaén. Iodine deficiency is one of the leading causes of thyroid dysfunction and goiter, and adequate iodine prophylaxis with iodized salt, milk, and dairy products, or iodine supplementation have been shown to significantly improve iodine status in pregnancy. The purpose of this study was to assess iodine nutritional status in the general population of a iodine-deficient area with no previous institutional campaigns of iodine prophylaxis. A descriptive, cross-sectional study. Urinary iodine levels were measured in subjects from the Jaén healthcare district. The data were stratified by sex and age groups, and a survey was conducted on iodized salt consumption. Median and mean urinary iodine levels were 110.59 mcg/L and 130.11 mcg/L respectively. Urinary iodine levels were significantly higher in schoolchildren as compared to other age groups (161.52μg/L vs 109.33μg/L in subjects older than 65 years). Forty-three percent of the population had urinary iodine levels less than 100μg/L, and 68% of women of childbearing age had levels less than 150μg/L. Iodine nutritional status appears to be adequate, but the proportion of the population with urinary iodine levels less than 100μg/L is still very high, and iodized salt consumption is much less common than recommended by the WHO. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  9. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    PubMed

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  10. Early diagnosis of Budd-Chiari syndrome by computed tomography and ultrasonography: report of five cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baert, A.L.; Fevery, J.; Marchal, G.

    1983-03-01

    In 5 patients with Budd-Chiari syndrome, computed tomography after intravenous bolus injection of iodinated contrast agents demonstrated images not previously seen in other diseases. The images are compatible with stagnation of contrast material at the periphery of the liver. In 3 of the 5 cases, grey-scale ultrasonography failed to document the normal hepatic veins draining into the inferior caval vein, but showed an intrahepatic network of comma-shaped venous structures. It is proposed that these two noninvasive approaches can help in establishing an early diagnosis.

  11. Computed tomography of orbital tumors in the dog.

    PubMed

    LeCouteur, R A; Fike, J R; Scagliotti, R H; Cann, C E

    1982-04-15

    Computed tomography (CT) was used to investigate orbital tumors in 3 dogs. Tumors were clearly defined on transverse CT scans by their inherent density and gross distortion of normal orbital anatomy. Dorsal images synthesized from the original transverse scans were also used to visualize size and extent of tumors. Use of an iodinated contrast medium did not appear to improve localization of tumors in the orbit but was useful for identification of tumor extension into the calvaria. It was concluded that CT offered advantages over existing methods of radiographic diagnosis of orbital tumors and exophthalmos.

  12. Efficient Proximity Computation Techniques Using ZIP Code Data for Smart Cities †

    PubMed Central

    Murdani, Muhammad Harist; Hong, Bonghee

    2018-01-01

    In this paper, we are interested in computing ZIP code proximity from two perspectives, proximity between two ZIP codes (Ad-Hoc) and neighborhood proximity (Top-K). Such a computation can be used for ZIP code-based target marketing as one of the smart city applications. A naïve approach to this computation is the usage of the distance between ZIP codes. We redefine a distance metric combining the centroid distance with the intersecting road network between ZIP codes by using a weighted sum method. Furthermore, we prove that the results of our combined approach conform to the characteristics of distance measurement. We have proposed a general and heuristic approach for computing Ad-Hoc proximity, while for computing Top-K proximity, we have proposed a general approach only. Our experimental results indicate that our approaches are verifiable and effective in reducing the execution time and search space. PMID:29587366

  13. Efficient Proximity Computation Techniques Using ZIP Code Data for Smart Cities †.

    PubMed

    Murdani, Muhammad Harist; Kwon, Joonho; Choi, Yoon-Ho; Hong, Bonghee

    2018-03-24

    In this paper, we are interested in computing ZIP code proximity from two perspectives, proximity between two ZIP codes ( Ad-Hoc ) and neighborhood proximity ( Top-K ). Such a computation can be used for ZIP code-based target marketing as one of the smart city applications. A naïve approach to this computation is the usage of the distance between ZIP codes. We redefine a distance metric combining the centroid distance with the intersecting road network between ZIP codes by using a weighted sum method. Furthermore, we prove that the results of our combined approach conform to the characteristics of distance measurement. We have proposed a general and heuristic approach for computing Ad-Hoc proximity, while for computing Top-K proximity, we have proposed a general approach only. Our experimental results indicate that our approaches are verifiable and effective in reducing the execution time and search space.

  14. Sensitive monitoring of iodine species in sea water using capillary electrophoresis: vertical profiles of dissolved iodine in the Pacific Ocean.

    PubMed

    Huang, Zhuo; Ito, Kazuaki; Morita, Isamu; Yokota, Kuriko; Fukushi, Keiichi; Timerbaev, Andrei R; Watanabe, Shuichi; Hirokawa, Takeshi

    2005-08-01

    Using a novel high-sensitivity capillary electrophoretic method, vertical distributions of iodate, iodide, total inorganic iodine, dissolved organic iodine and total iodine in the North Pacific Ocean (0-5500 m) were determined without any sample pre-treatment other than UV irradiation before total iodine analysis. An extensive set of data demonstrated that the iodine behaviour in the ocean water collected during a cruise in the North Pacific Ocean in February-March 2003 was not conservative but correlated with variations in concentrations of dissolved oxygen and nutrient elements such as silicon, nitrogen and phosphorus. This suggests that the vertical distribution of iodine is associated with biological activities. The dissolved organic iodine was found in the euphotic zone in accord with observations elsewhere in the oceans. The vertical profile of dissolved organic iodine also appears to be related to biogeochemical activity. The concentrations of all measured iodine species vary noticeably above 1000 m but only minor latitudinal changes occur below 1000 m and slight vertical alterations can be observed below 2400 m. These findings are thought to reflect the stratification of nutrients and iodine species with different biological activities in the water column.

  15. Use of iodine for water disinfection: iodine toxicity and maximum recommended dose.

    PubMed Central

    Backer, H; Hollowell, J

    2000-01-01

    Iodine is an effective, simple, and cost-efficient means of water disinfection for people who vacation, travel, or work in areas where municipal water treatment is not reliable. However, there is considerable controversy about the maximum safe iodine dose and duration of use when iodine is ingested in excess of the recommended daily dietary amount. The major health effect of concern with excess iodine ingestion is thyroid disorders, primarily hypothyroidism with or without iodine-induced goiter. A review of the human trials on the safety of iodine ingestion indicates that neither the maximum recommended dietary dose (2 mg/day) nor the maximum recommended duration of use (3 weeks) has a firm basis. Rather than a clear threshold response level or a linear and temporal dose-response relationship between iodine intake and thyroid function, there appears to be marked individual sensitivity, often resulting from unmasking of underlying thyroid disease. The use of iodine for water disinfection requires a risk-benefit decision based on iodine's benefit as a disinfectant and the changes it induces in thyroid physiology. By using appropriate disinfection techniques and monitoring thyroid function, most people can use iodine for water treatment over a prolonged period of time. PMID:10964787

  16. Evolution of urinary iodine excretion over eleven years in an adult population.

    PubMed

    Gutiérrez-Repiso, Carolina; Colomo, Natalia; Rojo-Martinez, Gemma; Valdés, Sergio; Tapia, Maria J; Esteva, Isabel; Ruiz de Adana, Maria S; Rubio-Martin, Elehazara; Lago-Sampedro, Ana; Santiago, Piedad; Velasco, Ines; Garcia-Fuentes, Eduardo; Moreno, Jose C; Soriguer, Federico

    2015-08-01

    Few prospective cohort studies have evaluated dietary iodine intake and urinary iodine concentrations in the general adult population. We assess the evolution of urinary iodine excretion and factors that may influence it in an adult population followed for 11 years. A population-based cohort study was undertaken in Pizarra (Spain). In the three study phases (baseline (n = 886), and 6 (n = 788) and 11 years later (n = 501)), participants underwent an interview and a standardized clinical examination that included a food questionnaire, and thyroid hormone and urinary iodine determinations. Subjects with thyroid dysfunction, palpable goiter or urinary iodine excretion >400 μg/L were excluded. Urinary iodine increased over the years (100.6 ± 70.0 μg/L at baseline vs. 125.4 ± 95.2 μg/L at 6 years and 141.6 ± 81.4 μg/L at 11 years; p < 0.0001). Urinary iodine was significantly higher in subjects who reported iodized salt consumption and in subjects with a higher intake of dairy products (p < 0.05). Consumption of iodized salt (Risk ratio (RR) = 1.23, 95% CI [1.01-2.05]) and dairy products (RR = 2.07, 95% CI [1.01-4.23]), and a baseline urinary iodine concentration ≥100 μg/L (RR = 1.26, 95% CI [1.04-1.53]) were significantly associated with urinary iodine concentrations ≥100 μg/L at 11 years. There is no correlation between thyroid function (TSH, free triiodothyronine or free thyroxine levels) and urinary iodine concentrations in conditions of iodine sufficiency. The increase in urinary iodine concentrations over eleven years is associated with an increase in iodized salt intake and with the dairy products intake, and possibly with a higher iodine content of dairy products. However, individual variability in urinary iodine excretion was not fully explained by dietary iodine intake alone; previous urinary iodine concentrations were also important. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  17. Thyroglobulin level at week 16 of pregnancy is superior to urinary iodine concentration in revealing preconceptual and first trimester iodine supply

    PubMed Central

    Katko, Monika; Gazso, Andrea Anett; Hircsu, Ildiko; Bhattoa, Harjit Pal; Molnar, Zsuzsanna; Kovacs, Bela; Andrasi, David; Aranyosi, Janos; Makai, Rita; Veress, Lajos; Torok, Olga; Bodor, Miklos; Samson, Laszlo

    2017-01-01

    Abstract Pregnant women are prone to iodine deficiency due to the increased need for iodine during gestation. Progress has recently occurred in establishing serum thyroglobulin (Tg) as an iodine status biomarker, but there is no accepted reference range for iodine sufficiency during pregnancy. An observational study was conducted in 164 pregnant women. At week 16 of gestation urinary iodine concentration (UIC), serum Tg, and thyroid functions were measured, and information on the type of iodine supplementation and smoking were recorded. The parameters of those who started iodine supplementation (≥150 μg/day) at least 4 weeks before pregnancy (n = 27), who started at the detection of pregnancy (n = 51), and who had no iodine supplementation (n = 74) were compared. Sufficient iodine supply was found in the studied population based on median UIC (162 μg/L). Iodine supplementation ≥150 μg/day resulted in higher median UIC regardless of its duration (nonusers: 130 μg/L vs. prepregnancy iodine starters: 240 μg/L, and pregnancy iodine starters: 205 μg/L, p < .001, and p = .023, respectively). Median Tg value of pregnancy starters was identical to that of nonusers (14.5 vs. 14.6 μg/L), whereas prepregnancy starters had lower median Tg (9.1 μg/L, p = .018). Serum Tg concentration at week 16 of pregnancy showed negative relationship (p = .010) with duration of iodine supplementation and positive relationship (p = .008) with smoking, a known interfering factor of iodine metabolism, by multiple regression analysis. Serum Tg at week 16 of pregnancy may be a promising biomarker of preconceptual and first trimester maternal iodine status, the critical early phase of foetal brain development. PMID:28593684

  18. Chalcogenide aerogels as sorbents for radioactive iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subrahmanyam, Kota S.; Sarma, Debajit; Malliakas, Christos

    Iodine (129I) is one of the radionuclides released in nuclear fuel reprocessing and poses risk to public safety due to its involvement in human metabolic processes. In order to prevent the leaching of hazardous radioactive iodine into the environment, its effective capture and sequestration is pivotal. In the context of finding a suitable matrix for capturing radioactive iodine the chalcogels, NiMoS4, CoMoS4, Sb4Sn4S12, Zn2Sn2S6, and CoSx (x = 4-5) were explored as iodine sorbents. All the chalcogels showed high uptake, reaching up to 225 mass% (2.25 g/g) of the final mass owing to strong chemical and physical iodine-chalcogen interactions. Analysismore » of the iodine-loaded specimens revealed that the iodine chemically reacted with Sb4Sn4S12, Zn2Sn2S6, and CoSx to form metal complexes SbI3, SnI4, and, KI respectively. The NiMoS4 and CoMoS4 chalcogels did not appear to undergo a chemical reaction with iodine since iodide complexes were not observed with these samples. Once heated, the iodine-loaded chalcogels released iodine in the temperature range of 75 °C to 220 °C, depending on the nature of iodine speciation. In the case of Sb4Sn4S12 and Zn2Sn2S6 iodine release was observed around 150 °C in the form of SnI4 and SbI3, respectively. The NiMoS4, CoMoS4, and CoSx released iodine at ~75 °C, which is consistent with physisorbed iodine. Preliminary investigations on consolidation of iodine-loaded Zn2Sn2S6 with Sb2S3 as a glass forming additive showed the content of iodine in consolidated glass ingots at around 25 mass%.« less

  19. FDA regulations regarding iodine addition to foods and labeling of foods containing added iodine12

    PubMed Central

    Trumbo, Paula R

    2016-01-01

    The US Food and Drug Administration (FDA) regulates the addition of iodine to infant formulas, the iodization of salt, and the addition of salt and iodine to foods. The required amount of iodine in infant formulas is based on caloric content, and the label must provide the iodine content per 100 kcal. Cuprous iodide and potassium iodide may be added to table salt as a source of dietary iodine at a maximum amount of 0.01%; if added, the label must indicate that the salt is iodized. Table salt to which iodine has not been added must bear the statement, “This salt does not supply iodide, a necessary nutrient.” If a nutrient is to be appropriately added to a food for the purpose of correcting a dietary insufficiency, there should be sufficient scientific information available to demonstrate a nutritional deficiency and/or identify a public health problem. Furthermore, the population groups that would benefit from the proposed fortification should be identified. If iodine is added to a food, the percent Daily Value of iodine must be listed. There are no FDA regulations governing ingredient standards for dietary supplements. As a result, some dietary supplements include iodine and others do not. If a supplement contains iodine, the Supplement Facts label must list iodine as a nutrient ingredient. If iodine is not listed on the Supplement Facts label, then it has not been added. There are similarities between the FDA, which establishes US food regulations and policies, and the Codex Alimentarius (Codex), which develops international food standards and guidelines under the aegis of the FAO and the WHO. Both the FDA and Codex call for the labeling of table salt to indicate fortification with iodine, voluntary labeling of iodine on foods, and a Daily Value (called a Nutrient Reference Value by Codex) of 150 μg for iodine. PMID:27534626

  20. FDA regulations regarding iodine addition to foods and labeling of foods containing added iodine.

    PubMed

    Trumbo, Paula R

    2016-09-01

    The US Food and Drug Administration (FDA) regulates the addition of iodine to infant formulas, the iodization of salt, and the addition of salt and iodine to foods. The required amount of iodine in infant formulas is based on caloric content, and the label must provide the iodine content per 100 kcal. Cuprous iodide and potassium iodide may be added to table salt as a source of dietary iodine at a maximum amount of 0.01%; if added, the label must indicate that the salt is iodized. Table salt to which iodine has not been added must bear the statement, "This salt does not supply iodide, a necessary nutrient." If a nutrient is to be appropriately added to a food for the purpose of correcting a dietary insufficiency, there should be sufficient scientific information available to demonstrate a nutritional deficiency and/or identify a public health problem. Furthermore, the population groups that would benefit from the proposed fortification should be identified. If iodine is added to a food, the percent Daily Value of iodine must be listed. There are no FDA regulations governing ingredient standards for dietary supplements. As a result, some dietary supplements include iodine and others do not. If a supplement contains iodine, the Supplement Facts label must list iodine as a nutrient ingredient. If iodine is not listed on the Supplement Facts label, then it has not been added. There are similarities between the FDA, which establishes US food regulations and policies, and the Codex Alimentarius (Codex), which develops international food standards and guidelines under the aegis of the FAO and the WHO. Both the FDA and Codex call for the labeling of table salt to indicate fortification with iodine, voluntary labeling of iodine on foods, and a Daily Value (called a Nutrient Reference Value by Codex) of 150 μg for iodine. © 2016 American Society for Nutrition.

  1. Central venous catheter integrity during mechanical power injection of iodinated contrast medium.

    PubMed

    Macha, Douglas B; Nelson, Rendon C; Howle, Laurens E; Hollingsworth, John W; Schindera, Sebastian T

    2009-12-01

    To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

  2. MRI and CT contrast media extravasation: A systematic review.

    PubMed

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R

    2018-03-01

    This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.

  3. Contrast-enhanced digital mammography (CEDM): imaging modeling, computer simulations, and phantom study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Jing, Zhenxue; Smith, Andrew

    2005-04-01

    Contrast enhanced digital mammography (CEDM), which is based upon the analysis of a series of x-ray projection images acquired before/after the administration of contrast agents, may provide physicians critical physiologic and morphologic information of breast lesions to determine the malignancy of lesions. This paper proposes to combine the kinetic analysis (KA) of contrast agent uptake/washout process and the dual-energy (DE) contrast enhancement together to formulate a hybrid contrast enhanced breast-imaging framework. The quantitative characteristics of materials and imaging components in the x-ray imaging chain, including x-ray tube (tungsten) spectrum, filter, breast tissues/lesions, contrast agents (non-ionized iodine solution), and selenium detector, were systematically modeled. The contrast-noise-ration (CNR) of iodinated lesions and mean absorbed glandular dose were estimated mathematically. The x-ray techniques optimization was conducted through a series of computer simulations to find the optimal tube voltage, filter thickness, and exposure levels for various breast thicknesses, breast density, and detectable contrast agent concentration levels in terms of detection efficiency (CNR2/dose). A phantom study was performed on a modified Selenia full field digital mammography system to verify the simulated results. The dose level was comparable to the dose in diagnostic mode (less than 4 mGy for an average 4.2 cm compressed breast). The results from the computer simulations and phantom study are being used to optimize an ongoing clinical study.

  4. Comparison of the sensitivity and specificity of 5 image sets of dual-energy computed tomography for detecting first-pass myocardial perfusion defects compared with positron emission tomography.

    PubMed

    Li, Wenhuan; Zhu, Xiaolian; Li, Jing; Peng, Cheng; Chen, Nan; Qi, Zhigang; Yang, Qi; Gao, Yan; Zhao, Yang; Sun, Kai; Li, Kuncheng

    2014-12-01

    The sensitivity and specificity of 5 different image sets of dual-energy computed tomography (DECT) for the detection of first-pass myocardial perfusion defects have not systematically been compared using positron emission tomography (PET) as a reference standard. Forty-nine consecutive patients, with known or strongly suspected of coronary artery disease, were prospectively enrolled in our study. Cardiac DECT was performed at rest state using a second-generation 128-slice dual-source CT. The DECT data were reconstructed to iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images by different postprocessing techniques. The myocardial perfusion defects on DECT images were visually assessed by 5 observers, using standard 17-segment model. Diagnostic accuracy of 5 image sets was assessed using nitrogen-13 ammonia PET as the gold standard. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC), and AUCs were compared using the method of DeLong. The DECT and PET examinations were successfully completed in 30 patients and a total of 90 territories and 510 segments were analyzed. Cardiac PET revealed myocardial perfusion defects in 56 territories (62%) and 209 segments (41%). The AUC of iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images were 0.986, 0.934, 0.913, 0.881, and 0.871, respectively, on a per-territory basis. These values were 0.922, 0.813, 0.779, 0.763, and 0.728, respectively, on a per-segment basis. DECT iodine maps shows high sensitivity and specificity, and is superior to other DECT image sets for the detection of myocardial perfusion defects in the first-pass myocardial perfusion.

  5. Rotational spectra of rare isotopic species of fluoroiodomethane: determination of the equilibrium structure from rotational spectroscopy and quantum-chemical calculations.

    PubMed

    Puzzarini, Cristina; Cazzoli, Gabriele; López, Juan Carlos; Alonso, José Luis; Baldacci, Agostino; Baldan, Alessandro; Stopkowicz, Stella; Cheng, Lan; Gauss, Jürgen

    2012-07-14

    Supported by accurate quantum-chemical calculations, the rotational spectra of the mono- and bi-deuterated species of fluoroiodomethane, CHDFI and CD(2)FI, as well as of the (13)C-containing species, (13)CH(2)FI, were recorded for the first time. Three different spectrometers were employed, a Fourier-transform microwave spectrometer, a millimeter/submillimter-wave spectrometer, and a THz spectrometer, thus allowing to record a huge portion of the rotational spectrum, from 5 GHz up to 1.05 THz, and to accurately determine the ground-state rotational and centrifugal-distortion constants. Sub-Doppler measurements allowed to resolve the hyperfine structure of the rotational spectrum and to determine the complete iodine quadrupole-coupling tensor as well as the diagonal elements of the iodine spin-rotation tensor. The present investigation of rare isotopic species of CH(2)FI together with the results previously obtained for the main isotopologue [C. Puzzarini, G. Cazzoli, J. C. López, J. L. Alonso, A. Baldacci, A. Baldan, S. Stopkowicz, L. Cheng, and J. Gauss, J. Chem. Phys. 134, 174312 (2011); G. Cazzoli, A. Baldacci, A. Baldan, and C. Puzzarini, Mol. Phys. 109, 2245 (2011)] enabled us to derive a semi-experimental equilibrium structure for fluoroiodomethane by means of a least-squares fit procedure using the available experimental ground-state rotational constants together with computed vibrational corrections. Problems related to the missing isotopic substitution of fluorine and iodine were overcome thanks to the availability of an accurate theoretical equilibrium geometry (computed at the coupled-cluster singles and doubles level augmented by a perturbative treatment of triple excitations).

  6. Demonstration of iodine K-edge imaging by use of an energy-discrimination X-ray computed tomography system with a cadmium telluride detector.

    PubMed

    Abudurexiti, Abulajiang; Kameda, Masashi; Sato, Eiichi; Abderyim, Purkhet; Enomoto, Toshiyuki; Watanabe, Manabu; Hitomi, Keitaro; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Takahashi, Kiyomi; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2010-07-01

    An energy-discrimination K-edge X-ray computed tomography (CT) system is useful for increasing the contrast resolution of a target region by utilizing contrast media. The CT system has a cadmium telluride (CdTe) detector, and a projection curve is obtained by linear scanning with use of the CdTe detector in conjunction with an X-stage. An object is rotated by a rotation step angle with use of a turntable between the linear scans. Thus, CT is carried out by repetition of the linear scanning and the rotation of an object. Penetrating X-ray photons from the object are detected by the CdTe detector, and event signals of X-ray photons are produced with use of charge-sensitive and shaping amplifiers. Both the photon energy and the energy width are selected by use of a multi-channel analyzer, and the number of photons is counted by a counter card. For performing energy discrimination, a low-dose-rate X-ray generator for photon counting was developed; the maximum tube voltage and the minimum tube current were 110 kV and 1.0 microA, respectively. In energy-discrimination CT, the tube voltage and the current were 60 kV and 20.0 microA, respectively, and the X-ray intensity was 0.735 microGy/s at 1.0 m from the source and with a tube voltage of 60 kV. Demonstration of enhanced iodine K-edge X-ray CT was carried out by selection of photons with energies just beyond the iodine K-edge energy of 33.2 keV.

  7. A nanocomposite of Au-AgI core/shell dimer as a dual-modality contrast agent for x-ray computed tomography and photoacoustic imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orza, Anamaria; Wu, Hui; Li, Yuancheng

    Purpose: To develop a core/shell nanodimer of gold (core) and silver iodine (shell) as a dual-modal contrast-enhancing agent for biomarker targeted x-ray computed tomography (CT) and photoacoustic imaging (PAI) applications. Methods: The gold and silver iodine core/shell nanodimer (Au/AgICSD) was prepared by fusing together components of gold, silver, and iodine. The physicochemical properties of Au/AgICSD were then characterized using different optical and imaging techniques (e.g., HR- transmission electron microscope, scanning transmission electron microscope, x-ray photoelectron spectroscopy, energy-dispersive x-ray spectroscopy, Z-potential, and UV-vis). The CT and PAI contrast-enhancing effects were tested and then compared with a clinically used CT contrast agentmore » and Au nanoparticles. To confer biocompatibility and the capability for efficient biomarker targeting, the surface of the Au/AgICSD nanodimer was modified with the amphiphilic diblock polymer and then functionalized with transferrin for targeting transferrin receptor that is overexpressed in various cancer cells. Cytotoxicity of the prepared Au/AgICSD nanodimer was also tested with both normal and cancer cell lines. Results: The characterizations of prepared Au/AgI core/shell nanostructure confirmed the formation of Au/AgICSD nanodimers. Au/AgICSD nanodimer is stable in physiological conditions for in vivo applications. Au/AgICSD nanodimer exhibited higher contrast enhancement in both CT and PAI for dual-modality imaging. Moreover, transferrin functionalized Au/AgICSD nanodimer showed specific binding to the tumor cells that have a high level of expression of the transferrin receptor. Conclusions: The developed Au/AgICSD nanodimer can be used as a potential biomarker targeted dual-modal contrast agent for both or combined CT and PAI molecular imaging.« less

  8. Excessive iodine intake does not increase the recurrence rate of graves' disease after withdrawal of the antithyroid drug in an iodine-replete area.

    PubMed

    Park, Sun Mi; Cho, Yoon Young; Joung, Ji Young; Sohn, Seo Young; Kim, Sun Wook; Chung, Jae Hoon

    2015-03-01

    The relationship between iodine intake and effects of antithyroid drugs (ATD) for Graves' disease, especially in iodine-deficient areas, has been demonstrated in many studies. However, it was not clear how chronic high iodine intake influenced the effectiveness of ATD in an iodine-replete area. This study aimed to clarify the effect of iodine intake on clinical outcomes of Graves' disease after discontinuation of ATD in Korea, an iodine-replete area. A total of 142 patients with Graves' disease who visited the outpatient clinic regularly and stopped their ATD between October 2011 and April 2013 were enrolled in our study. Urinary iodine concentration (UIC) was measured just before and after the discontinuation of ATD. Median UIC was not significantly different between the remission and relapse groups, as well as among the four treatment groups (group 1, remission after initial treatment; group 2, remission after repeated treatment; group 3, early relapse within a year; group 4, late relapse after a year). Remission rates did not show a significant difference between the excessive iodine intake (UIC ≥300 μg/l) and average iodine intake groups (UIC <300 μg/l). The present study suggests that excessive iodine intake does not have an effect on the clinical outcomes of Graves' disease in an iodine-replete area, and therefore diet control with iodine restriction might not be necessary in the management of Graves' disease.

  9. Excessive Iodine Intake Does Not Increase the Recurrence Rate of Graves' Disease after Withdrawal of the Antithyroid Drug in an Iodine-Replete Area

    PubMed Central

    Park, Sun Mi; Cho, Yoon Young; Joung, Ji Young; Sohn, Seo Young; Kim, Sun Wook; Chung, Jae Hoon

    2015-01-01

    Background and Objectives The relationship between iodine intake and effects of antithyroid drugs (ATD) for Graves' disease, especially in iodine-deficient areas, has been demonstrated in many studies. However, it was not clear how chronic high iodine intake influenced the effectiveness of ATD in an iodine-replete area. This study aimed to clarify the effect of iodine intake on clinical outcomes of Graves' disease after discontinuation of ATD in Korea, an iodine-replete area. Methods A total of 142 patients with Graves' disease who visited the outpatient clinic regularly and stopped their ATD between October 2011 and April 2013 were enrolled in our study. Urinary iodine concentration (UIC) was measured just before and after the discontinuation of ATD. Results Median UIC was not significantly different between the remission and relapse groups, as well as among the four treatment groups (group 1, remission after initial treatment; group 2, remission after repeated treatment; group 3, early relapse within a year; group 4, late relapse after a year). Remission rates did not show a significant difference between the excessive iodine intake (UIC ≥300 μg/l) and average iodine intake groups (UIC <300 μg/l). Conclusions The present study suggests that excessive iodine intake does not have an effect on the clinical outcomes of Graves' disease in an iodine-replete area, and therefore diet control with iodine restriction might not be necessary in the management of Graves' disease. PMID:25960960

  10. Thyroid function changes related to use of iodinated water in the U.S. Space Program.

    PubMed

    McMonigal, K A; Braverman, L E; Dunn, J T; Stanbury, J B; Wear, M L; Hamm, P B; Sauer, R L; Billica, R D; Pool, S L

    2000-11-01

    The National Aeronautics and Space Administration (NASA) has used iodination as a method of microbial disinfection of potable water systems in U.S. spacecraft and long-duration habitability modules. A review of thyroid function tests of NASA astronauts who had consumed iodinated water during spaceflight was conducted. Thyroid function tests of all past and present astronauts were reviewed. Medical records of astronauts with a diagnosis of thyroid disease were reviewed. Iodine consumption by space crews from water and food was determined. Serum thyroid-stimulating hormone (TSH) and urinary iodine excretion from space crews were measured following modification of the Space Shuttle potable water system to remove most of the iodine. Mean TSH significantly increased in 134 astronauts who had consumed iodinated water during spaceflight. Serum TSH, and urine iodine levels of Space Shuttle crewmembers who flew following modification of the potable water supply system to remove iodine did not show a statistically significant change. There was no evidence supporting association between clinical thyroid disease and the number of spaceflights, amount of iodine consumed, or duration of iodine exposure. It is suggested that pharmacological doses of iodine consumed by astronauts transiently decrease thyroid function, as reflected by elevated serum TSH values. Although adverse effects of excess iodine consumption in susceptible individuals are well documented, exposure to high doses of iodine during spaceflight did not result in a statistically significant increase in long-term thyroid disease in the astronaut population.

  11. [Iodine and thyroid gland with or without nuclear catastrophe].

    PubMed

    Dilas, Ljiljana Todorović; Bajkin, Ivana; Icin, Tijana; Paro, Jovanka Novaković; Zavisić, Branka Kovacev

    2012-01-01

    Iodine, as a trace element, is a necessary and limiting substrate for thyroid gland hormone synthesis. It is an essential element that enables the thyroid gland to produce thyroid hormones thyroxine (T4) and triiodothyronine (T3). Synthesis of Thyroid Hormones and Iodine Metabolism. Three iodine molecules are added to make triiodothyronine, and four for thyroxine - the two key hormones produced by the thyroid gland. Iodine deficiency The proper daily amount of iodine is required for optimal thyroid function. Iodine deficiency can cause hypothyroidism, developmental brain disorders and goiter. Iodine deficiency is the single most common cause of preventable mental retardation and brain damage in the world. It also decreases child survival, causes goiters, and impairs growth and development. Iodine deficiency disorders in pregnant women cause miscarriages, stillbirths, and other complications. Children with iodine deficiency disorders can grow up stunted, apathetic, mentally retarded, and incapable of normal movements, speech or hearing. Excessive Iodine Intake. Excessive iodine intake, which can trigger a utoimmune thyroid disease and dysfunction. is on the other side. Iodine use in Case of Nuclear Catastrophe. In addition to other severe consuquences of radioactivity, high amount of radioactive iodine causes significant increase in incidence of thyroid gland carcinoma after some of the nuclear catastrophes (Hiroshima, Nagasaki, Chernobyl, Fukushima). The incidence of thyroid carcinoma was increased mostly in children. This paper was aimed at clarifying some of the possibilities of prevention according to the recommendations given by the World Health Organization.

  12. Teratology Public Affairs Committee Position Paper: Iodine Deficiency in Pregnancy

    PubMed Central

    Obican, Sarah G.; Jahnke, Gloria D.; Soldin, Offie P.; Scialli, Anthony R.

    2013-01-01

    Iodine deficiency is an important nutritional deficiency, with more than 2 billion people worldwide estimated to be at risk. The developing fetus and young children are particularly at risk. During pregnancy and lactation, iodine requirements increase, whether in iodine-poor or iodine-sufficient countries, making the mother and the developing fetus vulnerable. The American Thyroid Association (ATA) recommends 250 micrograms per day of iodine intake for pregnant and lactating women. The thyroid gland is able to adapt to the changes associated with pregnancy as long as sufficient iodine is present. Dietary intake is the sole source of iodine, which is essential to the synthesis of thyroid hormones. Iodine is found in multiple dietary sources including iodized salt, dairy products, seaweed, and fish. Prenatal vitamins containing iodine are a good source of iodine, but iodine content in multivitamin supplements is highly variable. Congenital hypothyroidism is associated with cretinism. Clinical hypothyroidism has been associated with increased risk of poor perinatal outcome including prematurity, low birth weight, miscarriage, preeclampsia, fetal death, and impaired fetal neurocognitive development. Subclinical hypothyroidism is also associated with poor pregnancy outcomes and potential fetal neurocognitive deficits, but the data are more variable than those for clinical hypothyroidism. We concur with the ATA recommendation that all pregnant and lactating women should ingest (through diet and supplements) 250 micrograms of iodine daily. To achieve this goal, we recommend that all pregnant and lactating women take daily iodine supplementation of 150 micrograms. PMID:22903940

  13. Teratology public affairs committee position paper: iodine deficiency in pregnancy.

    PubMed

    Obican, Sarah G; Jahnke, Gloria D; Soldin, Offie P; Scialli, Anthony R

    2012-09-01

    Iodine deficiency is an important nutritional deficiency, with more than 2 billion people worldwide estimated to be at risk. The developing fetus and young children are particularly at risk. During pregnancy and lactation, iodine requirements increase, whether in iodine-poor or iodine-sufficient countries, making the mother and the developing fetus vulnerable. The American Thyroid Association (ATA) recommends 250 micrograms per day of iodine intake for pregnant and lactating women. The thyroid gland is able to adapt to the changes associated with pregnancy as long as sufficient iodine is present. Dietary intake is the sole source of iodine, which is essential to the synthesis of thyroid hormones. Iodine is found in multiple dietary sources including iodized salt, dairy products, seaweed, and fish. Prenatal vitamins containing iodine are a good source of iodine, but iodine content in multivitamin supplements is highly variable. Congenital hypothyroidism is associated with cretinism. Clinical hypothyroidism has been associated with increased risk of poor perinatal outcome including prematurity, low birth weight, miscarriage, preeclampsia, fetal death, and impaired fetal neurocognitive development. Subclinical hypothyroidism is also associated with poor pregnancy outcomes and potential fetal neurocognitive deficits, but the data are more variable than those for clinical hypothyroidism. We concur with the ATA recommendation that all pregnant and lactating women should ingest (through diet and supplements) 250 micrograms of iodine daily. To achieve this goal, we recommend that all pregnant and lactating women take daily iodine supplementation of 150 micrograms. Copyright © 2012 Wiley Periodicals, Inc.

  14. Modeling fission product vapor transport in the Falcon facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepherd, I.M.; Drossinos, Y.; Benson, C.G.

    1995-05-01

    An extensive database of aerosol Experiments exists and has been used for checking aerosol transport codes. Data for fission product vapor transport are harder to find. Some qualitative data are available, but the Falcon thermal gradient tube tests carried out at AEA Technology`s laboratories in Winfrith, England, mark the first serious attempt to provide a set of experiments suitable for the validation of codes that predict the transport and condensation of realistic mixtures of fission product vapors. Four of these have been analyzed to check how well the computer code VICTORIA can predict the most important phenomena. Of the fourmore » experiments studied, two are reference cases (FAL-17 and FAL-19), one is a case without boric acid (FAL-18), and the other is run in a reducing atmosphere (FAL-20). The results show that once the vapors condense onto aerosols, VICTORIA can predict their deposition rather well. The dominant mechanism is thermophoresis, and each element deposits with more or less the same deposition velocity. The behavior of the vapors is harder to interpret. Essentially, it is important to know the temperature at which each element condenses. It is clear from the measurements that this temperature changed from test to test-caused mostly by the different speciation as the composition of the carrier gas and the relative concentration of other fission products changed. Only in the test with a steam atmosphere and without boric acid was the assumption valid that most of the iodine is cesium iodide and most of the cesium is cesium hydroxide. In general, VICTORIA predicts that, with the exception of cesium, there will be less variation in the speciation-and, hence, variation in the deposition-between tests than is in fact observed. VICTORIA underpredicts the volatility of most elements, and this is partly a consequence of the ideal solution assumption and partly an overestimation of vapor/aerosol interactions.« less

  15. Volume accumulator design analysis computer codes

    NASA Technical Reports Server (NTRS)

    Whitaker, W. D.; Shimazaki, T. T.

    1973-01-01

    The computer codes, VANEP and VANES, were written and used to aid in the design and performance calculation of the volume accumulator units (VAU) for the 5-kwe reactor thermoelectric system. VANEP computes the VAU design which meets the primary coolant loop VAU volume and pressure performance requirements. VANES computes the performance of the VAU design, determined from the VANEP code, at the conditions of the secondary coolant loop. The codes can also compute the performance characteristics of the VAU's under conditions of possible modes of failure which still permit continued system operation.

  16. "Hour of Code": Can It Change Students' Attitudes toward Programming?

    ERIC Educational Resources Information Center

    Du, Jie; Wimmer, Hayden; Rada, Roy

    2016-01-01

    The Hour of Code is a one-hour introduction to computer science organized by Code.org, a non-profit dedicated to expanding participation in computer science. This study investigated the impact of the Hour of Code on students' attitudes towards computer programming and their knowledge of programming. A sample of undergraduate students from two…

  17. Stabilisation of microalgae: Iodine mobilisation under aerobic and anaerobic conditions.

    PubMed

    Han, Wei; Clarke, William; Pratt, Steven

    2015-10-01

    Mobilisation of iodine during microalgae stabilisation was investigated, with the view of assessing the potential of stabilised microalgae as an iodine-rich fertiliser. An iodine-rich waste microalgae (0.35 ± 0.05 mg I g(-1) VS(added)) was stabilised under aerobic and anaerobic conditions. Iodine mobilisation was linearly correlated with carbon emission, indicating iodine was in the form of organoiodine. Comparison between iodine and nitrogen mobilisation relative to carbon emission indicated that these elements were, at least in part, housed separately within the cells. After stabilisation, there were 0.22 ± 0.05 and 0.19 ± 0.01 mg g(-1) VS(added) iodine remaining in the solid in the aerobic and anaerobic processed material respectively, meaning 38 ± 5.0% (aerobic) and 50 ± 8.6% (anaerobic) of the iodine were mobilised, and consequently lost from the material. The iodine content of the stabilised material is comparable to the iodine content of some seaweed fertilisers, and potentially satisfies an efficient I-fertilisation dose. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Talking about Code: Integrating Pedagogical Code Reviews into Early Computing Courses

    ERIC Educational Resources Information Center

    Hundhausen, Christopher D.; Agrawal, Anukrati; Agarwal, Pawan

    2013-01-01

    Given the increasing importance of soft skills in the computing profession, there is good reason to provide students withmore opportunities to learn and practice those skills in undergraduate computing courses. Toward that end, we have developed an active learning approach for computing education called the "Pedagogical Code Review"…

  19. Review of Iodine Nutrition in Iranian Population in the Past Quarter of Century.

    PubMed

    Delshad, Hossein; Azizi, Fereidoun

    2017-10-01

    Iodine deficiency is one of the most important health problems worldwide. The overall aim of this study was a narrative review of the past and present status of iodine nutrition in the Iranian population to gather and provide valuable background data in this field for future studies. For this narrative literature review study, published internal (SID, Iran doc, Iran medex) and international (Web of knowledge, Pubmed, SCOPUS) source studies were searched using the following medical subject heading terms: Iodine, IDD (iodine deficiency disorders), UIC (urinary iodine concentration), Goiter, IQ (intelligence quotient), thyroid hormone, Iodine and pregnancy, Iodine and breast feeding, as well as Iodized salt, reporting the prevalence of iodine deficiency and iodine nutrition status of different target populations in Iran over 25 years, between 1988 - 2014, were assessed. We found 185 abstracts by literature search, of which, 161 papers that were as case reports, animal study, with lack of regional or national data were excluded after full text evaluation. Finally 24 full papers covering regional or national data on iodine nutrition of the study population were eligible for our review. Iodine deficiency, as a nutritional problem, had been identified in Iran since 1968. In the years 1987 - 1989, a few studies were done to define the prevalence of iodine deficiency in the country. The first nation-wide survey was performed in 14 provinces. Based on this survey all provinces were suffering of endemic goiter. In 1989, iodine deficiency was recognized as a major problem for community health. In 1990, salt factories began to produce iodized salt and in 1996, the second national survey was performed in 26 provinces. This survey indicated that 40% of boys and 50% of girls have goiter, with a median urinary iodine excretion of 205 µg/L. The 3rd national survey in 2001 showed that the total goiter rate is 9.8% and median UIC of 165 μg/L. In 2007, the 3th national survey was conducted 17 years after iodized salt consumption by Iranian households. In this study the total goiter rate and median urinary iodine was 5.7% and 145 μg/L, respectively. The 5th national survey conducted in 2013, showed household consumption of iodized salt for all provinces was 98% and the median urinary iodine of school children was 161 μg/L. Following the 5th national survey, the 1st national survey of the iodine status and thyroid function of pregnant women, conducted in 10 provinces in the different region of the country, documented a median UIC for pregnant women of 87.3 µg/L, results of this national survey clarified that despite iodine sufficiency of school children in Iran, pregnant women have moderate iodine deficiency and need iodine supplementation. The success of iodine deficiency control program depends on well designed programmatic steps and mandatory iodized salt consumption in certain situations. The iodine intake of school children is sufficient, however, Iranian pregnant women are suffering from moderate iodine deficiency and need iodine supplementation.

  20. Biofortification of Cereals With Foliar Selenium and Iodine Could Reduce Hypothyroidism

    PubMed Central

    Lyons, Graham

    2018-01-01

    Concurrent selenium and iodine deficiencies are widespread, in both developing and developed countries. Salt iodisation is insufficient to ensure global iodine adequacy, with an estimated one-third of humanity at risk of hypothyroidism and associated iodine deficiency disorders (IDD). Agronomic biofortification of food crops, especially staples such as cereals, which are consumed widely, may be an effective component of a food system strategy to reduce selenium and iodine malnutrition. Iodine and selenium are needed in the optimum intake range for thyroid health, hence joint biofortification makes sense for areas deficient in both. Foliar application is recommended as the most effective, efficient, least wasteful method for selenium and iodine biofortification. Currently, selenium is easier to increase in grain, fruit, and storage roots by this method, being more phloem mobile than iodine. Nevertheless, strategic timing (around heading is usually best), use of surfactants and co-application with potassium nitrate can increase the effectiveness of foliar iodine biofortification. More research is needed on iodine transporters and iodine volatilisation in plants, bioavailability of iodine in biofortified plant products, and roles for nano selenium and iodine in biofortification. For adoption, farmers need an incentive such as access to a premium functional food market, a subsidy or increased grain yield resulting from possible synergies with co-applied fertilisers, enhancers, fungicides, and insecticides. Further research is needed to inform these aspects of foliar agronomic biofortification.

  1. [Application of iodine metabolism analysis methods in thyroid diseases].

    PubMed

    Han, Jian-hua; Qiu, Ling

    2013-08-01

    The main physiological role of iodine in the body is to synthesize thyroid hormone. Both iodine deficiency and iodine excess can lead to severe thyroid diseases. While its role in thyroid diseases has increasingly been recognized, few relevant platforms and techniques for iodine detection have been available in China. This paper summarizes the advantages and disadvantages of currently iodine detection methods including direct titration, arsenic cerium catalytic spectrophotometry, chromatography with pulsed amperometry, colorimetry based on automatic biochemistry, inductively coupled plasma mass spectrometry, so as to optimize the iodine nutrition for patients with thyroid diseases.

  2. Guidelines for developing vectorizable computer programs

    NASA Technical Reports Server (NTRS)

    Miner, E. W.

    1982-01-01

    Some fundamental principles for developing computer programs which are compatible with array-oriented computers are presented. The emphasis is on basic techniques for structuring computer codes which are applicable in FORTRAN and do not require a special programming language or exact a significant penalty on a scalar computer. Researchers who are using numerical techniques to solve problems in engineering can apply these basic principles and thus develop transportable computer programs (in FORTRAN) which contain much vectorizable code. The vector architecture of the ASC is discussed so that the requirements of array processing can be better appreciated. The "vectorization" of a finite-difference viscous shock-layer code is used as an example to illustrate the benefits and some of the difficulties involved. Increases in computing speed with vectorization are illustrated with results from the viscous shock-layer code and from a finite-element shock tube code. The applicability of these principles was substantiated through running programs on other computers with array-associated computing characteristics, such as the Hewlett-Packard (H-P) 1000-F.

  3. Iodine Status in Pregnant Women, Lactating Mothers, and Newborns in an Area with More Than Two Decades of Successful Iodine Nutrition.

    PubMed

    Nazeri, Pantea; Zarghani, Najmeh Hamzavi; Mirmiran, Parvin; Hedayati, Mehdi; Mehrabi, Yadollah; Azizi, Fereidoun

    2016-07-01

    Pregnant women, lactating mothers, and their newborns constitute the target population for prevention and control of iodine deficiency. Hence, the aim of this study was to evaluate the iodine nutrition status among these vulnerable groups in an area with more than two decades of successful elimination of iodine deficiency. In this cross-sectional study conducted in health care centers of Tehran, 100 pregnant women and 84 lactating mothers and their newborn were randomly selected. Urinary iodine concentration and iodine content of salts were measured using the Sandell-Kolthoff and titration methods, respectively. Urinary iodine concentration <150 μg/L for pregnant women and <100 μg/L for lactating mothers and newborns was considered as iodine nutrition inadequacy, respectively. Median (interquartile range [IQR]) urinary iodine concentration (UIC) was 103 (59-155) μg/L in pregnant women, 77 (42-194) μg/L in lactating mothers, and 198 (84-260) μg/L in newborns. Median (IQR) iodine content of salt was 26 (21-30) ppm and 25 (18-28) ppm in pregnant women and lactating mothers, respectively (P = 0.462). Iodine content of salt was significantly correlated with UIC of pregnant women (r = 0.24, P = 0.019), but no correlation was found among lactating mothers (r = 0.12, P = 0.316). Neonatal UIC was significantly correlated with iodine content of salt consumed by their mothers (r = 0.49, P = 0.001). Despite suboptimal iodine status among subgroups of Tehranian pregnant and lactating women, iodine nutrition status of newborns was within optimal levels, which may be explained by a compensatory mechanism in the mammary glands.

  4. An Increase in Consuming Adequately Iodized Salt May Not Be Enough to Rectify Iodine Deficiency in Pregnancy in an Iodine-Sufficient Area of China

    PubMed Central

    Wang, Zhifang; Zhu, Wenming; Mo, Zhe; Wang, Yuanyang; Mao, Guangming; Wang, Xiaofeng; Lou, Xiaoming

    2017-01-01

    Universal salt iodization (USI) has been implemented for two decades in China. It is crucial to periodically monitor iodine status in the most vulnerable population, such as pregnant women. A cross-sectional study was carried out in an evidence-proved iodine-sufficient province to evaluate iodine intake in pregnancy. According to the WHO/UNICEF/ICCIDD recommendation criteria of adequate iodine intake in pregnancy (150–249 µg/L), the median urinary iodine concentration (UIC) of the total 8159 recruited pregnant women was 147.5 µg/L, which indicated pregnant women had iodine deficiency at the province level. Overall, 51.0% of the total study participants had iodine deficiency with a UIC < 150 µg/L and only 32.9% of them had adequate iodine. Participants living in coastal areas had iodine deficiency with a median UIC of 130.1 µg/L, while those in inland areas had marginally adequate iodine intake with a median UIC of 158.1 µg/L (p < 0.001). Among the total study participants, 450 pregnant women consuming non-iodized salt had mild-moderate iodine deficiency with a median UIC of 99.6 µg/L; 7363 pregnant women consuming adequately iodized salt had a lightly statistically higher median UIC of 151.9 µg/L, compared with the recommended adequate level by the WHO/UNICEF/ICCIDD (p < 0.001). Consuming adequately iodized salt seemed to lightly increase the median UIC level, but it may not be enough to correct iodine nutrition status to an optimum level as recommended by the WHO/UNICEF/ICCIDD. We therefore suggest that, besides strengthening USI policy, additional interventive measure may be needed to improve iodine intake in pregnancy. PMID:28230748

  5. An Increase in Consuming Adequately Iodized Salt May Not Be Enough to Rectify Iodine Deficiency in Pregnancy in an Iodine-Sufficient Area of China.

    PubMed

    Wang, Zhifang; Zhu, Wenming; Mo, Zhe; Wang, Yuanyang; Mao, Guangming; Wang, Xiaofeng; Lou, Xiaoming

    2017-02-20

    Universal salt iodization (USI) has been implemented for two decades in China. It is crucial to periodically monitor iodine status in the most vulnerable population, such as pregnant women. A cross-sectional study was carried out in an evidence-proved iodine-sufficient province to evaluate iodine intake in pregnancy. According to the WHO/UNICEF/ICCIDD recommendation criteria of adequate iodine intake in pregnancy (150-249 µg/L), the median urinary iodine concentration (UIC) of the total 8159 recruited pregnant women was 147.5 µg/L, which indicated pregnant women had iodine deficiency at the province level. Overall, 51.0% of the total study participants had iodine deficiency with a UIC < 150 µg/L and only 32.9% of them had adequate iodine. Participants living in coastal areas had iodine deficiency with a median UIC of 130.1 µg/L, while those in inland areas had marginally adequate iodine intake with a median UIC of 158.1 µg/L ( p < 0.001). Among the total study participants, 450 pregnant women consuming non-iodized salt had mild-moderate iodine deficiency with a median UIC of 99.6 µg/L; 7363 pregnant women consuming adequately iodized salt had a lightly statistically higher median UIC of 151.9 µg/L, compared with the recommended adequate level by the WHO/UNICEF/ICCIDD ( p < 0.001). Consuming adequately iodized salt seemed to lightly increase the median UIC level, but it may not be enough to correct iodine nutrition status to an optimum level as recommended by the WHO/UNICEF/ICCIDD. We therefore suggest that, besides strengthening USI policy, additional interventive measure may be needed to improve iodine intake in pregnancy.

  6. More than a decade of iodine prophylaxis is needed to eradicate goiter among school age children in a moderately iodine-deficient region.

    PubMed

    Erdoğan, Murat Faik; Demir, Ozgür; Emral, Rifat; Kamel, Ahmet Nuri; Erdoğan, Gürbüz

    2009-03-01

    There are many studies regarding the effect of iodine supplementation on goiter, but relatively few reports on the duration of iodine supplementation required to eradicate goiter in iodine-deficient regions. In the current study, we aimed to determine goiter prevalence as determined by sonographic methods, as it relates to changes in median urinary iodine concentrations (UIC) among school age children (SAC), ages 9-11. This study was performed in Ankara, Turkey, before and 5-10 years after mandatory iodination of table salt. Three hundred to 400 SAC from the same primary schools were studied every year by measurement of UIC as part of Turkish Iodine Surveys. Sonographically determined thyroid volume of the SAC had been measured before the mandatory iodination in 1997 and 5-10 years afterward, in 2002 and 2007. The prevalence of goiter in children was evaluated using World Health Organization/International Council for the Control of Iodine Deficiency Disorders recommendations for age and sex. Moderate iodine deficiency was present in 1997 (median UIC, 25.5 microg/L), and it improved to mild iodine deficiency in 2001 (median UIC, 87 microg/L). Sufficient iodine intake (median UIC, 117 microg/L) was achieved by the year 2004. Goiter prevalence was 25% in 1997, 12.3% in 2001, and decreased to 1.3% in 2004. The time required to normalize the prevalence of goiter in SAC living in a moderately iodine-deficient environment was at least a decade. To achieve a goiter rate of less than 5% among SAC, it may require that, as a population, they were born and grew up under conditions of iodine sufficiency.

  7. The Helicopter Antenna Radiation Prediction Code (HARP)

    NASA Technical Reports Server (NTRS)

    Klevenow, F. T.; Lynch, B. G.; Newman, E. H.; Rojas, R. G.; Scheick, J. T.; Shamansky, H. T.; Sze, K. Y.

    1990-01-01

    The first nine months effort in the development of a user oriented computer code, referred to as the HARP code, for analyzing the radiation from helicopter antennas is described. The HARP code uses modern computer graphics to aid in the description and display of the helicopter geometry. At low frequencies the helicopter is modeled by polygonal plates, and the method of moments is used to compute the desired patterns. At high frequencies the helicopter is modeled by a composite ellipsoid and flat plates, and computations are made using the geometrical theory of diffraction. The HARP code will provide a user friendly interface, employing modern computer graphics, to aid the user to describe the helicopter geometry, select the method of computation, construct the desired high or low frequency model, and display the results.

  8. Analysis of iodinated quorum sensing peptides by LC-UV/ESI ion trap mass spectrometry.

    PubMed

    Janssens, Yorick; Verbeke, Frederick; Debunne, Nathan; Wynendaele, Evelien; Peremans, Kathelijne; De Spiegeleer, Bart

    2018-02-01

    Five different quorum sensing peptides (QSP) were iodinated using different iodination techniques. These iodinated peptides were analyzed using a C 18 reversed phase HPLC system, applying a linear gradient of water and acetonitrile containing 0.1% (m/v) formic acid as mobile phase. Electrospray ionization (ESI) ion trap mass spectrometry was used for the identification of the modified peptides, while semi-quantification was performed using total ion current (TIC) spectra. Non-iodinated peptides and mono- and di-iodinated peptides (NIP, MIP and DIP respectively) were well separated and eluted in that order. Depending on the used iodination method, iodination yields varied from low (2%) to high (57%).

  9. The iodine-plutonium-xenon age of the Moon-Earth system revisited.

    PubMed

    Avice, G; Marty, B

    2014-09-13

    Iodine-plutonium-xenon isotope systematics have been used to re-evaluate time constraints on the early evolution of the Earth-atmosphere system and, by inference, on the Moon-forming event. Two extinct radionuclides ((129)I, T1/2=15.6 Ma and (244)Pu, T1/2=80 Ma) have produced radiogenic (129)Xe and fissiogenic (131-136)Xe, respectively, within the Earth, the related isotope fingerprints of which are seen in the compositions of mantle and atmospheric Xe. Recent studies of Archaean rocks suggest that xenon atoms have been lost from the Earth's atmosphere and isotopically fractionated during long periods of geological time, until at least the end of the Archaean eon. Here, we build a model that takes into account these results. Correction for Xe loss permits the computation of new closure ages for the Earth's atmosphere that are in agreement with those computed for mantle Xe. The corrected Xe formation interval for the Earth-atmosphere system is [Formula: see text] Ma after the beginning of Solar System formation. This time interval may represent a lower limit for the age of the Moon-forming impact. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  10. Visualization of subcutaneous insulin injections by x-ray computed tomography

    NASA Astrophysics Data System (ADS)

    Thomsen, M.; Poulsen, M.; Bech, M.; Velroyen, A.; Herzen, J.; Beckmann, F.; Feidenhans'l, R.; Pfeiffer, F.

    2012-11-01

    We report how the three-dimensional structure of subcutaneous injections of soluble insulin can be visualized by x-ray computed tomography using an iodine based contrast agent. The injections investigated are performed ex vivo in porcine adipose tissue. Full tomography scans carried out at a laboratory x-ray source with a total acquisition time of about 1 min yield CT-images with an effective pixel size of 109 × 109 μm2. The depots are segmented using a modified Chan-Vese algorithm and we are able to observe differences in the shape of the injection depot and the position of the depot in the skin among equally performed injections. To overcome the beam hardening artefacts, which affect the quantitative prediction of the volume injected, we additionally present results concerning the visualization of two injections using synchrotron radiation. The spatial concentration distribution of iodine is calculated to show the dilution of the insulin drug inside the depot. Characterisation of the shape of the depot and the spatial concentration profile of the injected fluid is important knowledge when improving the clinical formulation of an insulin drug, the performance of injection devices and when predicting the effect of the drug through biomedical simulations.

  11. Enhanced fault-tolerant quantum computing in d-level systems.

    PubMed

    Campbell, Earl T

    2014-12-05

    Error-correcting codes protect quantum information and form the basis of fault-tolerant quantum computing. Leading proposals for fault-tolerant quantum computation require codes with an exceedingly rare property, a transversal non-Clifford gate. Codes with the desired property are presented for d-level qudit systems with prime d. The codes use n=d-1 qudits and can detect up to ∼d/3 errors. We quantify the performance of these codes for one approach to quantum computation known as magic-state distillation. Unlike prior work, we find performance is always enhanced by increasing d.

  12. Convergence acceleration of the Proteus computer code with multigrid methods

    NASA Technical Reports Server (NTRS)

    Demuren, A. O.; Ibraheem, S. O.

    1992-01-01

    Presented here is the first part of a study to implement convergence acceleration techniques based on the multigrid concept in the Proteus computer code. A review is given of previous studies on the implementation of multigrid methods in computer codes for compressible flow analysis. Also presented is a detailed stability analysis of upwind and central-difference based numerical schemes for solving the Euler and Navier-Stokes equations. Results are given of a convergence study of the Proteus code on computational grids of different sizes. The results presented here form the foundation for the implementation of multigrid methods in the Proteus code.

  13. Implementation of radiation shielding calculation methods. Volume 1: Synopsis of methods and summary of results

    NASA Technical Reports Server (NTRS)

    Capo, M. A.; Disney, R. K.

    1971-01-01

    The work performed in the following areas is summarized: (1) Analysis of Realistic nuclear-propelled vehicle was analyzed using the Marshall Space Flight Center computer code package. This code package includes one and two dimensional discrete ordinate transport, point kernel, and single scatter techniques, as well as cross section preparation and data processing codes, (2) Techniques were developed to improve the automated data transfer in the coupled computation method of the computer code package and improve the utilization of this code package on the Univac-1108 computer system. (3) The MSFC master data libraries were updated.

  14. Nonuniform code concatenation for universal fault-tolerant quantum computing

    NASA Astrophysics Data System (ADS)

    Nikahd, Eesa; Sedighi, Mehdi; Saheb Zamani, Morteza

    2017-09-01

    Using transversal gates is a straightforward and efficient technique for fault-tolerant quantum computing. Since transversal gates alone cannot be computationally universal, they must be combined with other approaches such as magic state distillation, code switching, or code concatenation to achieve universality. In this paper we propose an alternative approach for universal fault-tolerant quantum computing, mainly based on the code concatenation approach proposed in [T. Jochym-O'Connor and R. Laflamme, Phys. Rev. Lett. 112, 010505 (2014), 10.1103/PhysRevLett.112.010505], but in a nonuniform fashion. The proposed approach is described based on nonuniform concatenation of the 7-qubit Steane code with the 15-qubit Reed-Muller code, as well as the 5-qubit code with the 15-qubit Reed-Muller code, which lead to two 49-qubit and 47-qubit codes, respectively. These codes can correct any arbitrary single physical error with the ability to perform a universal set of fault-tolerant gates, without using magic state distillation.

  15. Mission and System Advantages of Iodine Hall Thrusters

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Szabo, James; Pote, Bruce; Oleson, Steve; Kamhawi, Hani

    2014-01-01

    The exploration of alternative propellants for Hall thrusters continues to be of interest to the community. Investments have been made and continue for the maturation of iodine based Hall thrusters. Iodine testing has shown comparable performance to xenon. However, iodine has a higher storage density and resulting higher ?V capability for volume constrained systems. Iodine's vapor pressure is low enough to permit low-pressure storage, but high enough to minimize potential adverse spacecraft-thruster interactions. The low vapor pressure also means that iodine does not condense inside the thruster at ordinary operating temperatures. Iodine is safe, it stores at sub-atmospheric pressure, and can be stored unregulated for years on end; whether on the ground or on orbit. Iodine fills a niche for both low power (<1kW) and high power (>10kW) electric propulsion regimes. A range of missions have been evaluated for direct comparison of Iodine and Xenon options. The results show advantages of iodine Hall systems for both small and microsatellite application and for very large exploration class missions.

  16. Rapid increase in atmospheric iodine levels in the North Atlantic since the mid-20th century.

    PubMed

    Cuevas, Carlos A; Maffezzoli, Niccolò; Corella, Juan Pablo; Spolaor, Andrea; Vallelonga, Paul; Kjær, Helle A; Simonsen, Marius; Winstrup, Mai; Vinther, Bo; Horvat, Christopher; Fernandez, Rafael P; Kinnison, Douglas; Lamarque, Jean-François; Barbante, Carlo; Saiz-Lopez, Alfonso

    2018-04-13

    Atmospheric iodine causes tropospheric ozone depletion and aerosol formation, both of which have significant climate impacts, and is an essential dietary element for humans. However, the evolution of atmospheric iodine levels at decadal and centennial scales is unknown. Here, we report iodine concentrations in the RECAP ice-core (coastal East Greenland) to investigate how atmospheric iodine levels in the North Atlantic have evolved over the past 260 years (1750-2011), this being the longest record of atmospheric iodine in the Northern Hemisphere. The levels of iodine tripled from 1950 to 2010. Our results suggest that this increase is driven by anthropogenic ozone pollution and enhanced sub-ice phytoplankton production associated with the recent thinning of Arctic sea ice. Increasing atmospheric iodine has accelerated ozone loss and has considerably enhanced iodine transport and deposition to the Northern Hemisphere continents. Future climate and anthropogenic forcing may continue to amplify oceanic iodine emissions with potentially significant health and environmental impacts at global scale.

  17. The bioaccessibility of iodine in the biofortified vegetables throughout cooking and simulated digestion.

    PubMed

    Li, Rui; Li, De-Wang; Yan, Ai-Lan; Hong, Chun-Lai; Liu, Hui-Ping; Pan, Le-Hua; Song, Ming-Yi; Dai, Zhi-Xi; Ye, Ming-Li; Weng, Huan-Xin

    2018-01-01

    Biofortification of crops with exogenous iodine is a novel strategy to control iodine deficiency disorders (IDD). The bioaccessibility of iodine (BI) in the biofortified vegetables in the course of soaking, cooking and digestion, were examined. Under hydroponics, the concentration of iodine in leafstalks of the celery and pakchoi increased with increasing exogenous iodine concentration, 54.8-63.9% of the iodine absorbed by pakchoi was stored in the soluble cellular substance. Being soaked in water within 8 h, the iodine loss rate of the biofortified celery was 3.5-10.4% only. More than 80% of the iodine in the biofortified celery was retained after cooking under high temperature. The highest BI of the biofortified vegetables after digestion in simulated gastric and intestinal juice amounted to 74.08 and 68.28%, respectively. Factors influencing BI included pH, digestion duration, and liquid-to-solid ratio. The high BI of the biofortified vegetables provided a sound reference for the promotion of iodine biofortification as a tool to eliminate the IDD.

  18. Microbial Transformation of Iodine: From Radioisotopes to Iodine Deficiency.

    PubMed

    Yeager, Chris M; Amachi, Seigo; Grandbois, Russell; Kaplan, Daniel I; Xu, Chen; Schwehr, Kathy A; Santschi, Peter H

    2017-01-01

    Iodine is a biophilic element that is important for human health, both as an essential component of several thyroid hormones and, on the other hand, as a potential carcinogen in the form of radioiodine generated by anthropogenic nuclear activity. Iodine exists in multiple oxidation states (-1, 0, +1, +3, +5, and +7), primarily as molecular iodine (I 2 ), iodide (I - ), iodate [Formula: see text] , or organic iodine (org-I). The mobility of iodine in the environment is dependent on its speciation and a series of redox, complexation, sorption, precipitation, and microbial reactions. Over the last 15years, there have been significant advances in iodine biogeochemistry, largely spurred by renewed interest in the fate of radioiodine in the environment. We review the biogeochemistry of iodine, with particular emphasis on the microbial processes responsible for volatilization, accumulation, oxidation, and reduction of iodine, as well as the exciting technological potential of these fascinating microorganisms and enzymes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The Impact of Carrot Enriched in Iodine through Soil Fertilization on Iodine Concentration and Selected Biochemical Parameters in Wistar Rats.

    PubMed

    Piątkowska, Ewa; Kopeć, Aneta; Bieżanowska-Kopeć, Renata; Pysz, Mirosław; Kapusta-Duch, Joanna; Koronowicz, Aneta Agnieszka; Smoleń, Sylwester; Skoczylas, Łukasz; Ledwożyw-Smoleń, Iwona; Rakoczy, Roksana; Maślak, Edyta

    2016-01-01

    Iodine is one of the trace elements which are essential for mammalian life. The major objective of iodine biofortification of plants is to obtain food rich in this trace element, which may increase its consumption by various populations. Additionally, it may reduce the risk of iodine deficiency diseases. In this research for the first time we have assessed the bioavailability of iodine from raw or cooked carrot biofortified with this trace element on iodine concentration in selected tissues and various biochemical parameters as well as mRNA expression of some genes involved in iodine metabolism in Wistar rats. Statistically, a significantly higher iodine level was determined in urine, faeces and selected tissues of rats fed a diet containing biofortified raw carrot as compared to a diet without iodine and a diet containing control cooked carrot. Biofortified raw carrot significantly increased triiodothyronine concentration as compared to animals from other experimental groups. The highest thyroid stimulating hormone level was determined in rats fed control cooked carrots. mRNA expression of selected genes was affected by different dietary treatment in rats' hearts. Biofortified raw and cooked carrot could be taken into account as a potential source of iodine in daily diets to prevent iodine deficiency in various populations.

  20. Inactivation of infectious hematopoietic necrosis virus by low levels of iodine

    USGS Publications Warehouse

    Batts, William N.; Landolt, Marsha L.; Winton, James R.

    1991-01-01

    The fish rhabdovirus infectious hematopoietic necrosis virus (IHNV) was rapidly inactivated by extremely low concentrations of iodine in water. A 99.9% virus reduction was obtained in 7.5 s when virus (105PFU/ml) and iodine (0.1 mg/liter, final concentration) were combined in distilled-deionized or hatchery water. Iodine efficacy decreased at pHs greater than 7.5 or when proteinaceous material was added to the water. Bovine serum albumin blocked iodine inactivation of the virus more effectively than did equal concentrations of fetal bovine serum or river sediment. Sodium thiosulfate effectively neutralized free iodine. Powder, iodophor, and crystalline iodine solutions inactivated IHNV equally. Iodine rapidly inactivated IHNV isolates representing each of the five electropherotypes. Under the conditions used in this study, inactivation was not affected by temperature, salinity, or water hardness. When Dworshak National Fish Hatchery water was continuously treated to provide a free iodine concentration of 0.14 mg/liter, a 7.5-s exposure to iodine was sufficient to inactivate 99.9% of the IHNV. Iodine added to water that contained IHNV prevented infection of rainbow trout (Oncorhynchus mykiss) fry. These results suggest that the waterborne route of IHNV transmission can be blocked by adding low iodine concentrations to the water supplies of hatcheries.

  1. Thyroid disorders in mild iodine deficiency.

    PubMed

    Laurberg, P; Nøhr, S B; Pedersen, K M; Hreidarsson, A B; Andersen, S; Bülow Pedersen, I; Knudsen, N; Perrild, H; Jørgensen, T; Ovesen, L

    2000-11-01

    Comparative epidemiologic studies in areas with low and high iodine intake and controlled studies of iodine supplementation have demonstrated that the major consequence of mild-to-moderate iodine deficiency for the health of the population is an extraordinarily high occurrence of hyperthyroidism in elderly subjects, especially women, with risk of cardiac arrhythmias, osteoporosis, and muscle wasting. The hyperthyroidism is caused by autonomous nodular growth and function of the thyroid gland and it is accompanied by a high frequency of goiter. Pregnant women and small children are not immediately endangered but the consequences of severe iodine deficiency for brain development are grave and a considerable safety margin is advisable. Moreover, a shift toward less malignant types of thyroid cancer and a lower radiation dose to the thyroid in case of nuclear fallout support that mild-to-moderate iodine deficiency should be corrected. However, there is evidence that a high iodine intake may be associated with more autoimmune hypothyroidism, and that Graves' disease may manifest at a younger age and be more difficult to treat. Hence, the iodine intake should be brought to a level at which iodine deficiency disorders are avoided but not higher. Iodine supplementation programs should aim at relatively uniform iodine intake, avoiding deficient or excessive iodine intake in subpopulations. To adopt such a strategy, surveillance programs are needed.

  2. The Impact of Carrot Enriched in Iodine through Soil Fertilization on Iodine Concentration and Selected Biochemical Parameters in Wistar Rats

    PubMed Central

    Piątkowska, Ewa; Kopeć, Aneta; Bieżanowska-Kopeć, Renata; Pysz, Mirosław; Kapusta-Duch, Joanna; Koronowicz, Aneta Agnieszka; Smoleń, Sylwester; Skoczylas, Łukasz; Ledwożyw-Smoleń, Iwona; Rakoczy, Roksana; Maślak, Edyta

    2016-01-01

    Iodine is one of the trace elements which are essential for mammalian life. The major objective of iodine biofortification of plants is to obtain food rich in this trace element, which may increase its consumption by various populations. Additionally, it may reduce the risk of iodine deficiency diseases. In this research for the first time we have assessed the bioavailability of iodine from raw or cooked carrot biofortified with this trace element on iodine concentration in selected tissues and various biochemical parameters as well as mRNA expression of some genes involved in iodine metabolism in Wistar rats. Statistically, a significantly higher iodine level was determined in urine, faeces and selected tissues of rats fed a diet containing biofortified raw carrot as compared to a diet without iodine and a diet containing control cooked carrot. Biofortified raw carrot significantly increased triiodothyronine concentration as compared to animals from other experimental groups. The highest thyroid stimulating hormone level was determined in rats fed control cooked carrots. mRNA expression of selected genes was affected by different dietary treatment in rats’ hearts. Biofortified raw and cooked carrot could be taken into account as a potential source of iodine in daily diets to prevent iodine deficiency in various populations. PMID:27043135

  3. [Factors associated with nutritional status of iodine in Mexican preschool children].

    PubMed

    López Rodríguez, Guadalupe; Galván, Marcos; Silva Maldonado, Isabela; Chávez Dossetti, Michel

    2013-01-01

    Iodine deficiency is a public health problem in many developing countries where pregnant women and children are the more susceptible populations. To evaluate the association of iodine nutritional status with the weather, availability of iodine in salt, and degree of social exclusion in preschool children of the state of Hidalgo, Mexico. Cross-sectional study in 1,333 children < 5 years; in these, urinary iodine and iodine in the salt was measured, and annual average of humidity, type of location and degree of social marginalization in the localities where they lived was recorded. 24.5% of children evaluated had < 100 µg/l of urinary iodine excretion, and 28.6% of salt samples contained < 20 ppm of iodine; iodine urine average of wet weather children was lower (209.09 ± 6.8 µg/l) than in dry climates (274.7 ± 5.86 µg/l; p < 0.05); the iodine content of salt in children living communities with high levels of marginalization was less than with low marginalization (23.5 ± 1.2 and 32.9 ± 2.7 ppm, respectively; p < 0.01). The humidity and the degree of social marginalization of the locations were associated with lower iodine content of salt and urinary iodine in children evaluated.

  4. Estimation of habitual iodine intake in Japanese adults using 16 d diet records over four seasons with a newly developed food composition database for iodine.

    PubMed

    Katagiri, Ryoko; Asakura, Keiko; Sasaki, Satoshi; Hirota, Naoko; Notsu, Akiko; Miura, Ayako; Todoriki, Hidemi; Fukui, Mitsuru; Date, Chigusa

    2015-08-28

    Although habitual seaweed consumption in Japan would suggest that iodine intake in Japanese is exceptionally high, intake data from diet records are limited. In the present study, we developed a composition database of iodine and estimated the habitual intake of iodine among Japanese adults. Missing values for iodine content in the existing composition table were imputed based on established criteria. 16 d diet records (4 d over four seasons) from adults (120 women aged 30-69 years and 120 men aged 30-76 years) living in Japan were collected, and iodine intake was estimated. Habitual intake was estimated with the Best-power method. Totally, 995 food items were imputed. The distribution of iodine intake in 24 h was highly skewed, and approximately 55 % of 24 h values were < 300 μg/d. The median iodine intake in 24 h was 229 μg/d for women and 273 μg/d for men. All subjects consumed iodine-rich foods (kelp or soup stock) on one or more days of the sixteen survey days. The mean (median) habitual iodine intake was 1414 (857) μg/d for women and 1572 (1031) μg/d for men. Older participants had higher intake than younger participants. The major contributors to iodine intake were kelp (60 %) and soup stock (30 %). Habitual iodine intake among Japanese was sufficient or higher than the tolerable upper intake level, particularly in older generations. The association between high iodine intake as that observed in the present study and thyroid disease requires further study.

  5. Survey of iodine nutritional status in 2011, Zhejiang, China.

    PubMed

    Mao, Guangming; Ding, Gangqiang; Lou, Xiaoming; Zhang, Ronghua; Zheng, Pai; Mo, Zhe; Wang, Xiaofeng; Zhu, Wenming; Zhou, Jinshui; Gu, Fang

    2015-01-01

    Universal salt iodization (USI) was introduced in China in 1995, but whether the iodine status is optimal is questionable. This study was conducted to assess the iodine nutrition among Zhejiang population in coastal regions in China. A cross-sectional survey for iodine nutritional status was conducted with general population (n=10,350), including pregnant and lactating women (n=450 each) selected by stratified multistage sampling. Iodine content in drinking water, table salt and urine, were determined using arsenic-cerium catalytic spectrophotometry, the direct titration and the arsenic-cerium catalytic spectrophotometry, respectively, and daily iodine intake was estimated by 3 days of 24-hour recall method. The median iodine content in drinking water was 2.46 μg/L, Zhejiang belonged to the region of iodine deficiency in outer environment according to China standard. The median iodine content in table salt was 27.9 mg/kg, conforming to the standard requirements; the household coverage rate of qualified iodized salt reached 76.8%, which does not reach the standard requirement of WHO >90%. The dietary iodine intake of a reference individual averaged 379 μg/d, which indicated that the current iodine intake in diet was appropriate. In addition, the median urinary iodine concentration (UIC) was 162 μg/L in general population, and 130 μg/L in pregnant women, which didn't reach the standard requirements. The current dietary iodine intake in Zhejiang was generally sufficient and safe, but there is a risk of iodine deficiency among pregnant women and the population who do not consume iodized salt.

  6. Permeation of iodide from iodine-enriched yeast through porcine intestine.

    PubMed

    Ryszka, Florian; Dolińska, Barbara; Zieliński, Michał; Chyra, Dagmara; Dobrzański, Zbigniew

    2013-01-01

    Iodine deficiency is a common phenomenon, threatening the whole global human population. Recommended daily intake of iodine is 150 μg for adults and 250 μg for pregnant and breastfeeding women. About 50% of human population can be at risk of moderate iodine deficiency. Due to this fact, increased iodine supplementation is recommended, through intake of iodized mineral water and salt iodization. The aim of this study was to investigate permeation and absorption of iodide from iodine bioplex (experimental group) in comparison with potassium iodide (controls). Permeation and absorption processes were investigated in vitro using a porcine intestine. The experimental model was based on a standard Franz diffusion cell (FD-Cell). The iodine bioplex was produced using Saccharomyces cerevisiae yeast and whey powder: iodine content - 388 μg/g, total protein - 28.5%, total fat - 0.9%., glutamic acid - 41.2%, asparaginic acid - 29.4%, lysine - 24.8%; purchased from: F.Z.N.P. Biochefa, Sosnowiec, Poland. Potassium iodide was used as controls, at 388 μg iodine concentration, which was the same as in iodine-enriched yeast bioplex. A statistically significant increase in iodide permeation was observed for iodine-enriched yeast bioplex in comparison with controls - potassium iodide. After 5h the total amount of permeated iodide from iodine-enriched yeast bioplex was 85%, which is ~ 2-fold higher than controls - 37%. Iodide absorption was by contrast statistically significantly higher in controls - 7.3%, in comparison with 4.5% in experimental group with iodine-enriched yeast bioplex. Presented results show that iodide permeation process dominates over absorption in case of iodine-enriched yeast bioplex.

  7. Variation in the iodine concentrations of foods: considerations for dietary assessment1234

    PubMed Central

    Carriquiry, Alicia L; Spungen, Judith H; Murphy, Suzanne P; Pehrsson, Pamela R; Dwyer, Johanna T; Juan, WenYen; Wirtz, Mark S

    2016-01-01

    Background: Food-composition tables typically give measured nutrient concentrations in foods as a single summary value, often the mean, without providing information as to the shape of the distribution. Objective: Our objective was to explore how the statistical approach chosen to describe the iodine concentrations of foods affects the proportion of the population identified as having either insufficient or excessive iodine intakes. Design: We used food intake data reported by the 2009−2010 NHANES and measured iodine concentrations of Total Diet Study (TDS) foods from 4 US regions sampled in 2004–2011. We created 4 data sets, each by using a different summary statistic (median, mean, and 10th and 90th percentiles), to represent the iodine concentration distribution of each TDS food. We estimated the iodine concentration distribution of each food consumed by NHANES participants as the 4 iodine concentration summary statistics of a similar TDS food and used these, along with NHANES food intake data, to develop 4 estimates of each participant’s iodine intake on each survey day. Using the 4 estimates in turn, we calculated 4 usual iodine intakes for each sex- and age-specific subgroup. We then compared these to guideline values and developed 4 estimates of the proportions of each subgroup with deficient and excessive usual iodine intakes. Results: In general, the distribution of iodine intakes was poorly characterized when food iodine concentrations were expressed as mean values. In addition, mean values predicted lower prevalences of iodine deficiency than did median values. For example, in women aged 19–50 y, the estimated prevalence of iodine deficiency was 25% when based on median food iodine concentrations but only 5.8% when based on mean values. Conclusion: For nutrients such as iodine with highly variable concentrations in important food sources, we recommend that food-composition tables provide useful variability information, including the mean, SD, and median. PMID:27534633

  8. Impact of removing iodized salt on the iodine nutrition of children living in areas with variable iodine content in drinking water.

    PubMed

    Lv, Shengmin; Zhao, Yinglu; Li, Yanxia; Wang, Yuchun; Liu, Hua; Li, Yang; Zhao, Jun; Rutherford, Shannon

    2015-09-01

    Excess iodine in drinking water has emerged as a public health issue in China. This study assesses the effectiveness of removing iodized salt on reducing the iodine excess in populations living in high-iodine areas and also to identify the threshold value for safe levels of iodine in water. Twelve villages from 5 cities of Hebei Province with iodine content in drinking water ranging from 39 to 313 µg/l were selected to compare the urinary iodine content of children aged 8-10 years before and after removing iodized salt from their diet. For 3 villages where median water iodine content (MWIC) was below 110 µg/l, following the removal of iodized salt (the intervention), the median urinary iodine content (MUIC) reduced to under 300 µg/l decreasing from 365, 380, 351 to 247, 240, 281 µg/l, respectively. However, the MUIC in the 9 villages with MWIC above 110 µg/l remained higher than 300 µg/l. The children's MUIC correlated positively with the MWIC in the 12 villages (p ≤ 0.001). The linear regression equation after removing iodized salt was MUIC = 0.6761MWIC + 225.67, indicating that to keep the MUIC below 300 µg/l (the iodine excess threshold recommended by the WHO) requires the MWIC to be under 110 µg/l. Removing iodized salt could only correct the iodine excess in the population living in the areas with MWIC below 110 µg/l. In the areas with water iodine above 110 µg/l, interventions should be focused on seeking water with lower iodine content. This study suggests a threshold value of 110 µg/l of iodine in drinking water to maintain a safe level of dietary iodine.

  9. Variation in the iodine concentrations of foods: considerations for dietary assessment.

    PubMed

    Carriquiry, Alicia L; Spungen, Judith H; Murphy, Suzanne P; Pehrsson, Pamela R; Dwyer, Johanna T; Juan, WenYen; Wirtz, Mark S

    2016-09-01

    Food-composition tables typically give measured nutrient concentrations in foods as a single summary value, often the mean, without providing information as to the shape of the distribution. Our objective was to explore how the statistical approach chosen to describe the iodine concentrations of foods affects the proportion of the population identified as having either insufficient or excessive iodine intakes. We used food intake data reported by the 2009-2010 NHANES and measured iodine concentrations of Total Diet Study (TDS) foods from 4 US regions sampled in 2004-2011. We created 4 data sets, each by using a different summary statistic (median, mean, and 10th and 90th percentiles), to represent the iodine concentration distribution of each TDS food. We estimated the iodine concentration distribution of each food consumed by NHANES participants as the 4 iodine concentration summary statistics of a similar TDS food and used these, along with NHANES food intake data, to develop 4 estimates of each participant's iodine intake on each survey day. Using the 4 estimates in turn, we calculated 4 usual iodine intakes for each sex- and age-specific subgroup. We then compared these to guideline values and developed 4 estimates of the proportions of each subgroup with deficient and excessive usual iodine intakes. In general, the distribution of iodine intakes was poorly characterized when food iodine concentrations were expressed as mean values. In addition, mean values predicted lower prevalences of iodine deficiency than did median values. For example, in women aged 19-50 y, the estimated prevalence of iodine deficiency was 25% when based on median food iodine concentrations but only 5.8% when based on mean values. For nutrients such as iodine with highly variable concentrations in important food sources, we recommend that food-composition tables provide useful variability information, including the mean, SD, and median. © 2016 American Society for Nutrition.

  10. Green's function methods in heavy ion shielding

    NASA Technical Reports Server (NTRS)

    Wilson, John W.; Costen, Robert C.; Shinn, Judy L.; Badavi, Francis F.

    1993-01-01

    An analytic solution to the heavy ion transport in terms of Green's function is used to generate a highly efficient computer code for space applications. The efficiency of the computer code is accomplished by a nonperturbative technique extending Green's function over the solution domain. The computer code can also be applied to accelerator boundary conditions to allow code validation in laboratory experiments.

  11. Analytical modeling of operating characteristics of premixing-prevaporizing fuel-air mixing passages. Volume 2: User's manual

    NASA Technical Reports Server (NTRS)

    Anderson, O. L.; Chiappetta, L. M.; Edwards, D. E.; Mcvey, J. B.

    1982-01-01

    A user's manual describing the operation of three computer codes (ADD code, PTRAK code, and VAPDIF code) is presented. The general features of the computer codes, the input/output formats, run streams, and sample input cases are described.

  12. Automated apparatus and method of generating native code for a stitching machine

    NASA Technical Reports Server (NTRS)

    Miller, Jeffrey L. (Inventor)

    2000-01-01

    A computer system automatically generates CNC code for a stitching machine. The computer determines the locations of a present stitching point and a next stitching point. If a constraint is not found between the present stitching point and the next stitching point, the computer generates code for making a stitch at the next stitching point. If a constraint is found, the computer generates code for changing a condition (e.g., direction) of the stitching machine's stitching head.

  13. Computer codes developed and under development at Lewis

    NASA Technical Reports Server (NTRS)

    Chamis, Christos C.

    1992-01-01

    The objective of this summary is to provide a brief description of: (1) codes developed or under development at LeRC; and (2) the development status of IPACS with some typical early results. The computer codes that have been developed and/or are under development at LeRC are listed in the accompanying charts. This list includes: (1) the code acronym; (2) select physics descriptors; (3) current enhancements; and (4) present (9/91) code status with respect to its availability and documentation. The computer codes list is grouped by related functions such as: (1) composite mechanics; (2) composite structures; (3) integrated and 3-D analysis; (4) structural tailoring; and (5) probabilistic structural analysis. These codes provide a broad computational simulation infrastructure (technology base-readiness) for assessing the structural integrity/durability/reliability of propulsion systems. These codes serve two other very important functions: they provide an effective means of technology transfer; and they constitute a depository of corporate memory.

  14. The effects of iodine deficiency in pregnancy and infancy.

    PubMed

    Zimmermann, Michael B

    2012-07-01

    Iodine requirements are increased ≥ 50% during pregnancy. Iodine deficiency during pregnancy can cause maternal and fetal hypothyroidism and impair neurological development of the fetus. The consequences depend upon the timing and severity of the hypothyroidism; the most severe manifestation is cretinism. In moderate-to-severely iodine-deficient areas, controlled studies have demonstrated that iodine supplementation before or during early pregnancy eliminates new cases of cretinism, increases birthweight, reduces rates of perinatal and infant mortality and generally increases developmental scores in young children by 10-20%. Mild maternal iodine deficiency can cause thyroid dysfunction but whether it impairs cognitive and/or neurologic function in the offspring remains uncertain. Two meta-analyses have estimated that iodine-deficient populations experience a mean reduction in IQ of 12-13.5 points. In nearly all regions affected by iodine deficiency, salt iodisation is the most cost-effective way of delivering iodine and improving maternal and infant health. © 2012 Blackwell Publishing Ltd.

  15. Identification of Organic Iodine Compounds and Their Transformation Products in Edible Iodized Salt Using Liquid Chromatography-High Resolution Mass Spectrometry.

    PubMed

    Yun, Lifen; Peng, Yue'e; Chang, Qing; Zhu, Qingxin; Guo, Wei; Wang, Yanxin

    2017-07-05

    The consumption of edible iodized salt is a key strategy to control and eliminate iodine deficiency disorders worldwide. We herein report the identification of the organic iodine compounds present in different edible iodized salt products using liquid chromatography combined with high resolution mass spectrometry. A total of 38 organic iodine compounds and their transformation products (TPs) were identified in seaweed iodine salt from China. Our experiments confirmed that the TPs were generated by the replacement of I atoms from organic iodine compounds with Cl atoms. Furthermore, the organic iodine compound contents in 4 seaweed iodine salt samples obtained from different manufacturers were measured, with significant differences in content being observed. We expect that the identification of organic iodine compounds in salt will be important for estimating the validity and safety of edible iodized salt products.

  16. Regenerable biocide delivery unit

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Colombo, Gerald V. (Inventor); Jolly, Clifford D. (Inventor)

    1993-01-01

    A method and apparatus are disclosed for maintaining continuous, long-term microbial control in the water supply for potable, hygiene, and experimental water for space activities, as well as treatment of water supplies on Earth. The water purification is accomplished by introduction of molecular iodine into the water supply to impart a desired iodine residual. The water is passed through an iodinated anion exchange resin bed. The iodine is bound as I-(sub n) at the anion exchange sites and releases I(sub 2) into the water stream flowing through the bed. The concentration of I(sub 2) in the flowing water gradually decreases and, in the prior art, the ion-exchange bed has had to be replaced. In a preferred embodiment, a bed of iodine crystals is provided with connections for flowing water therethrough to produce a concentrated (substantially saturated) aqueous iodine solution which is passed through the iodinated resin bed to recharge the bed with bound iodine. The bed of iodine crystals is connected in parallel with the iodinated resin bed and is activated periodically (e.g., by timer, by measured flow of water, or by iodine residual level) to recharge the bed. Novelty resides in the capability of inexpensively and repeatedly regenerating the ion-exchange bed in situ.

  17. Iodine Nutritional Status of School Children in Nauru 2015

    PubMed Central

    Huang, Chun-Jui; Tseng, Chi-Lung; Chen, Harn-Shen; Garabwan, Chanda; Korovo, Samuela; Tang, Kam-Tsun; Won, Justin Ging-Shing; Hsieh, Chang-Hsun; Wang, Fan-Fen

    2016-01-01

    Little is known about iodine nutritional status in island countries in the Pacific Ocean. The primary objective of this study was to report for the first time the iodine nutritional status of people in Nauru. In addition, sources of iodine nutrition (i.e., water and salt) were investigated. A school-based cross-sectional survey of children aged 6–12 years was conducted in three primary schools of Nauru. Urinary iodine concentration (UIC) was determined by spot urine samples. Available water and salt samples in Nauru were collected for the measurement of iodine content. A food frequency questionnaire was conducted. The median UIC was 142 μg/L, and 25.2% and 7.4% of the population had median UIC below 100 μg/L and 50 μg/L, respectively. Natural iodine-containing foods such as seaweeds and agar were rare. Iodine was undetectable in Nauruan tank water, filtered tap water, and raindrops. Of the analyzed salt products, five kinds were non-iodized, and three were iodized (iodine content: 15 ppm, 65 ppm, and 68 ppm, respectively). The results indicate that the iodine status in Nauruan school children is adequate. Iodized salt may serve as an important source of iodine nutrition in Nauru. PMID:27563920

  18. Intelligence quotient and iodine intake: a cross-sectional study in children.

    PubMed

    Santiago-Fernandez, Piedad; Torres-Barahona, Rosario; Muela-Martínez, J Antonio; Rojo-Martínez, Gemma; García-Fuentes, Eduardo; Garriga, M José; León, Ana García; Soriguer, Federico

    2004-08-01

    The association between iodine deficiency and poor mental and psychomotor development is known. However, most studies were undertaken in areas of very low iodine intake. We investigated whether a similar association is found in schoolchildren from southern Europe with a median urinary iodine output of 90 microg/liter. Urinary iodine levels were measured in 1221 children who also completed a questionnaire about their usual dietary habits. Intelligence quotient (IQ) was measured by Cattell's g factor test. IQ was significantly higher in children with urinary iodine levels above 100 microg/liter. The risk of having an IQ below the 25th percentile was significantly related to the intake of noniodized salt and drinking milk less than once a day. As expected, the risk of having an IQ below 70 was greater in children with urinary iodine levels less than 100 microg/liter. In conclusion, this study demonstrates that the IQ of schoolchildren in a developed country can be influenced by iodine intake. The results support the possibility of improving the IQ of many children from areas with mild iodine deficiency by ensuring an iodine intake sufficient to achieve a urinary iodine concentration greater than 100 microg/liter.

  19. Iodine distribution in the environment as a limiting factor for roe deer antler development.

    PubMed

    Lehoczki, Róbert; Erdélyi, Károly; Sonkoly, Krisztina; Szemethy, László; Csányi, Sándor

    2011-02-01

    The iodine-containing hormones produced by the thyroid gland play a role in the complex neuro-hormonal regulation of antler development. The proper function of the thyroid depends on the adequate iodine supply of the organism, which is directly related to the iodine content of food and drinking water. The purpose of this study was to explore the connection between the iodine content of the water base, which has a strong correlation with the iodine concentration of environmental components available to animals, and the antler weight of roe deer (Capreolus capreolus) shot in Hungarian hunting areas. Using a general linear model, controlling for the collective effects of other environmental factors (deer population density, harvest rate, land use, and soil fertility information), the iodine content of the water base explained 51.4% of the total variance of antler weights. The results suggest that antler weights increase with increasing iodine concentration regardless of other factors; thus, the environmental iodine distribution can be a limiting factor suppressing roe deer performance assessed here as antler weight. Further experimental studies of controlled iodine uptake are needed to define the exact physiological iodine requirements of roe deer bucks.

  20. Evidence of iodine storage within thyroid stroma after iodine treatment: imaging by secondary ion mass spectometry (SIMS) microscopy in goitrous tissue.

    PubMed

    el May, M; Jeusset, J; el May, A; Mtimet, S; Fragu, P

    1996-06-01

    We measured the 127I distribution within tyroid tissue to find out where intrathyroid iodine was deposited during iodine treatment in eight Tunisian female patients (aged 33-58 yr) with endemic euthyroid goiter. Before surgery, five patients were treated during 6 months either by Lugol's solution (group 1: three patients) or by Lugol's and L-thyroxine (group 2: two patients). All patients remained euthyroid during the course of the treatment, which supplied 3.8 mg/day iodine. Three other patients did not receive Lugol's solution (control group). Secondary ion mass spectrometry microscopy was used to map 127-I quantitatively on thyroid sections. Specimens obtained at thyroid surgery were divided macroscopically into nodular and extranodular tissue and chemically fixed to preserve organified iodine. The iodine profile of patients in group 1 did not differ from that in group 2: large amounts of iodine were localized in thyroid follicles and stroma of both nodular and extranodular tissues. In the control group, iodine within stroma was found only in the extranodular tissue. Despite the limited number of patients studied, these data suggest that stromal iodine might represent a storage compartment in times of large iodine supply.

  1. Iodine and mental development of children 5 years old and under: a systematic review and meta-analysis.

    PubMed

    Bougma, Karim; Aboud, Frances E; Harding, Kimberly B; Marquis, Grace S

    2013-04-22

    Several reviews and meta-analyses have examined the effects of iodine on mental development. None focused on young children, so they were incomplete in summarizing the effects on this important age group. The current systematic review therefore examined the relationship between iodine and mental development of children 5 years old and under. A systematic review of articles using Medline (1980-November 2011) was carried out. We organized studies according to four designs: (1) randomized controlled trial with iodine supplementation of mothers; (2) non-randomized trial with iodine supplementation of mothers and/or infants; (3) prospective cohort study stratified by pregnant women's iodine status; (4) prospective cohort study stratified by newborn iodine status. Average effect sizes for these four designs were 0.68 (2 RCT studies), 0.46 (8 non-RCT studies), 0.52 (9 cohort stratified by mothers' iodine status), and 0.54 (4 cohort stratified by infants' iodine status). This translates into 6.9 to 10.2 IQ points lower in iodine deficient children compared with iodine replete children. Thus, regardless of study design, iodine deficiency had a substantial impact on mental development. Methodological concerns included weak study designs, the omission of important confounders, small sample sizes, the lack of cluster analyses, and the lack of separate analyses of verbal and non-verbal subtests. Quantifying more precisely the contribution of iodine deficiency to delayed mental development in young children requires more well-designed randomized controlled trials, including ones on the role of iodized salt.

  2. [Epidemiological investigation on thyroid disease among fertile women in different iodine intake areas of Shanxi province].

    PubMed

    Ren, Yanting; Jia, Qingzhen; Zhang, Xiangdong; Guo, Baisuo; Wen, Xinping; Zhang, Fengfeng; Wang, Yongping; Wang, Juanjuan

    2014-01-01

    To understand the prevalence of thyroid diseases and its influencing factors of iodine on thyroid gland function and autoimmune among fertile women in different iodine intake areas. Cross-sectional method was used for descriptive epidemiology. 236 women aged 19 to 45 years were sampled in 2011, in Shanxi province. Questionnaire was used to include general data on place, name, age etc. Sample of water from home, one time random urine sample and venous blood were collected to test the iodine contents using arsenic and cerium catalysis spectrophotometric methods. Finally, in blood, free triiodothyronine (FT3), free thyroxine (FT4), thyrotrophin (TSH) in blood were tested under auto-CLIA and anti-thyroid peroxidase (anti-TPO), anti-thyroglobulin (anti-TG) through radio-immunological methods. 1)The urine iodine's medians were 486.9 µg/L for fertile women in high iodine areas, and 192.6 µg/L in low iodine areas, with difference on urine iodine level statistically significant (Z = -10.676, P = 0.000). 2) Levels of blood FT3 and FT4 in women from high iodine areas were obviously lower than those from proper iodine areas(t = -2.884, P = 0.004; t = -2.862, P = 0.005), but the level of TSH in high iodine areas was higher than that of proper iodine areas(t = 2.332, P = 0.021). 3) In both areas, the rate of the thyroid dysfunction with positive antibodies was obviously higher than those with negative antibodies (χ² = 20.941, P = 0.000;χ² = 5.596, P = 0.018), while the rate of the thyroid dysfunction with positive antibodies and the level of TSH in the blood for high iodine women higher than those in women with proper iodine level(χ² = 5.708, P = 0.37;t = -2.177, P = 0.031). 4)The morbidity rate of inferior clinical hyperthyroidism for women in high iodine areas was obviously higher than those in proper iodine areas(χ² = 9.542, P = 0.003), while the morbidity rate of inferior clinical hypothyroidism for women with positive antibodies in two areas obviously higher than those with negative antibodies (χ² = 17.264, P = 0.000; χ² = 6.002, P = 0.044). Morbidity rate of inferior clinical hypothyroidism for women in high iodine areas was obviously higher than those in proper iodine areas, suggesting that there were potential risks of hypothyroidism for overdose iodine intake which causing the existence of positive thyroid antibodies. Monitoring programs on iodine nutrition and thyroid function among women living in high iodine areas should be strengthened.

  3. Reactivity effects in VVER-1000 of the third unit of the kalinin nuclear power plant at physical start-up. Computations in ShIPR intellectual code system with library of two-group cross sections generated by UNK code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zizin, M. N.; Zimin, V. G.; Zizina, S. N., E-mail: zizin@adis.vver.kiae.ru

    2010-12-15

    The ShIPR intellectual code system for mathematical simulation of nuclear reactors includes a set of computing modules implementing the preparation of macro cross sections on the basis of the two-group library of neutron-physics cross sections obtained for the SKETCH-N nodal code. This library is created by using the UNK code for 3D diffusion computation of first VVER-1000 fuel loadings. Computation of neutron fields in the ShIPR system is performed using the DP3 code in the two-group diffusion approximation in 3D triangular geometry. The efficiency of all groups of control rods for the first fuel loading of the third unit ofmore » the Kalinin Nuclear Power Plant is computed. The temperature, barometric, and density effects of reactivity as well as the reactivity coefficient due to the concentration of boric acid in the reactor were computed additionally. Results of computations are compared with the experiment.« less

  4. Reactivity effects in VVER-1000 of the third unit of the kalinin nuclear power plant at physical start-up. Computations in ShIPR intellectual code system with library of two-group cross sections generated by UNK code

    NASA Astrophysics Data System (ADS)

    Zizin, M. N.; Zimin, V. G.; Zizina, S. N.; Kryakvin, L. V.; Pitilimov, V. A.; Tereshonok, V. A.

    2010-12-01

    The ShIPR intellectual code system for mathematical simulation of nuclear reactors includes a set of computing modules implementing the preparation of macro cross sections on the basis of the two-group library of neutron-physics cross sections obtained for the SKETCH-N nodal code. This library is created by using the UNK code for 3D diffusion computation of first VVER-1000 fuel loadings. Computation of neutron fields in the ShIPR system is performed using the DP3 code in the two-group diffusion approximation in 3D triangular geometry. The efficiency of all groups of control rods for the first fuel loading of the third unit of the Kalinin Nuclear Power Plant is computed. The temperature, barometric, and density effects of reactivity as well as the reactivity coefficient due to the concentration of boric acid in the reactor were computed additionally. Results of computations are compared with the experiment.

  5. Effectiveness of the iodine prophylaxis model adopted in Poland.

    PubMed

    Szybinski, Z; Golkowski, F; Buziak-Bereza, M; Trofimiuk, M; Przybylik-Mazurek, E; Huszno, B; Bandurska-Stankiewicz, E; Bar-Andziak, E; Dorant, B; Kinalska, I; Lewinski, A; Klencki, M; Rybakowa, M; Sowinski, J; Szewczyk, L; Szponar, L; Wasik, R

    2008-04-01

    Most of the Polish territory has been classified as an iodine-deficient and endemic goiter area according to the International Council for Control of Iodine Deficiency (ICCIDD) criteria. In 1997 the obligatory model of iodine prophylaxis was implemented. Our investigations were aimed at the effectiveness of iodine prophylaxis in Poland. We assessed urinary iodine excretion and goiter prevalence in 5663 children aged 6-12 yr. The population of children from the same 27 schools was investigated from 1992 to 1994 (1406 girls and 1244 boys) and from 1999 to 2005 (1563 girls and 1450 boys) using identical laboratory and ultrasound methods. We found significant increase in iodine urinary concentration (median 52 microg/l vs 93 microg/l, p<0.001) with accompanying drop in goiter prevalence (29.6% vs 5.2%, p<0.001) after implementation of iodine prophylaxis. Iodine excretion distribution changed significantly after 1997 with an increase in the percentage of children with iodine urinary concentration above 100 microg/l from 10.8% to 45.4%, respectively. A significantly higher iodine urinary concentration was observed in lowlands compared to uplands both before and after implementation of iodine prophylaxis (median, 50 microg/l vs 57 microg/l and 86 microg/l vs 114 microg/l, respectively, p<0.001). The goiter prevalence did not differ between girls and boys from 1992 to 1994 (28.8% vs 30.5%, p=0.35) and 1999 to 2005 (5.5% vs 4.9%, p=0.45). Implementation of the new model of iodine prophylaxis in Poland in 1997 has led to significant increase in iodine urinary concentration and decrease in goiter prevalence among Polish schoolchildren. In the youngest group of children (6-8 yr olds), prevalence of goiter decreased to 3.2%--i.e. below endemic levels.

  6. The impact of iodine prophylaxis on thyroid 131-iodine uptake in the region of Krakow, Poland.

    PubMed

    Huszno, B; Hubalewska-Hoła, A; Bałdys-Waligórska, A; Sowa-Staszczak, A; Szybiński, Z

    2003-01-01

    Iodine prophylaxis was introduced in Poland in 1935. It was interrupted twice, the first time between 1939 and 1947 (due to the Second World War and its aftermath), and then between 1980 and 1986, due to the economical crisis in Poland at that time. A voluntary model of iodine prophylaxis (20 +/- 10 mg/kg of household salt) introduced in Poland in 1986, was followed by a mandatory model, implemented at the beginning of 1997, with 30 +/- 10 mg/kg of household salt. In the early sixties, in our Department of Endocrinology 24-hour iodine uptake test was introduced as a routine procedure for evaluating the thyroid gland. The reference value of this test increased in 1986 after discontinuation of iodine prophylaxis, and decreased in 1998, two years after re-implementation of the mandatory model of iodine prophylaxis. In 167 patients (147 with endemic goiter and 20 with no thyroid disturbances) examined between 1998 and 2000 the mean value of 24-hour iodine uptake was 27.3 +/- 10.4%, as compared to the mean value of 45,7 +/- 6.6 % in 1986. In patients with thyrotoxicosis the mean value of iodine uptake was 41.9% +/- 16.2 in 1999 (no.=614), 42.4% +/- 16.9 in 2000 (no.=644) and 37,7% +/- 17.2 at the beginning of 2001 (no.=328). The mean value of iodine uptake in patients with thyrotoxicosis before implementation of iodine prophylaxis was over 60%. The 24-hour thyroid radioiodine uptake test proved to be a useful indicator of changes of iodine intake in a iodine-deficient population. The data presented in this study confirm the importance and efficacy of the iodine prophylaxis introduced in Poland.

  7. Iodine and pregnancy - a UK cross-sectional survey of dietary intake, knowledge and awareness.

    PubMed

    Combet, E; Bouga, M; Pan, B; Lean, M E J; Christopher, C O

    2015-07-14

    Iodine is a key component of the thyroid hormones, which are critical for healthy growth, development and metabolism. The UK population is now classified as mildly iodine-insufficient. Adequate levels of iodine during pregnancy are essential for fetal neurodevelopment, and mild iodine deficiency is linked to developmental impairments. In the absence of prophylaxis in the UK, awareness of nutritional recommendations during pregnancy would empower mothers to make the right dietary choices leading to adequate iodine intake. The present study aimed to: estimate mothers' dietary iodine intake in pregnancy (using a FFQ); assess awareness of the importance of iodine in pregnancy with an understanding of existing pregnancy dietary and lifestyle recommendations with relevance for iodine; examine the level of confidence in meeting adequate iodine intake. A cross-sectional survey was conducted and questionnaires were distributed between August 2011 and February 2012 on local (Glasgow) and national levels (online electronic questionnaire); 1026 women, UK-resident and pregnant or mother to a child aged up to 36 months participated in the study. While self-reported awareness about general nutritional recommendations during pregnancy was high (96 %), awareness of iodine-specific recommendations was very low (12 %), as well as the level of confidence of how to achieve adequate iodine intake (28 %). Median pregnancy iodine intake, without supplements, calculated from the FFQ, was 190 μg/d (interquartile range 144-256μg/d), which was lower than that of the WHO's recommended intake for pregnant women (250 μg/d). Current dietary recommendations in pregnancy, and their dissemination, are found not to equip women to meet the requirements for iodine intake.

  8. Cognitive and motor functions of iodine-deficient but euthyroid children in Bangladesh do not benefit from iodized poppy seed oil (Lipiodol).

    PubMed

    Huda, S N; Grantham-McGregor, S M; Tomkins, A

    2001-01-01

    Iodine supplementation before pregnancy in iodine-deficient women prevents cretinism and neuromotor deficits in their offspring. It is unclear whether iodine supplementation benefits cognitive function in iodine-deficient school-aged children. We therefore conducted a double-blind, randomized, controlled trial of the effects of iodized poppy seed oil (Lipiodol) on cognitive and motor function and weight gain of iodine-deficient school children. The study was conducted with 305 children in grades 1 and 2 from 10 primary schools in two iodine-deficient areas in Bangladesh. The children were stratified by school and grade and randomly assigned to receive 400 mg of oral Lipiodol or a placebo. All children were given a battery of cognitive and motor function tests and had their weights, serum thyroxine (T4) and thyroid-stimulating hormone (TSH) and urinary iodine levels measured before and 4 mo after the intervention. On enrollment, both groups were moderately iodine deficient (median urinary iodine values: placebo group = 3.3 micromol/L, n = 148; iodine group = 3.1 micromol/L, n = 152; goiter prevalence in both groups >95%). However, their T4 and TSH levels were within the normal range. After 4 mo, there was a significant treatment effect on urinary iodine levels (P < 0.0001), but the levels of the treated group were still below normal (median = 7.9 micromol/L). No significant differences were found in T4 and TSH levels, weight gain, cognitive or motor function. The findings suggest that Lipiodol supplementation in moderately iodine-deficient children with normal T4 levels is unlikely to benefit their cognitive function. However, it remains possible that other iodine preparations may have benefits.

  9. IODINE CONTENT OF ENTERAL AND PARENTERAL NUTRITION SOLUTIONS.

    PubMed

    Willard, Devina L; Young, Lorraine S; He, Xuemei; Braverman, Lewis E; Pearce, Elizabeth N

    2017-07-01

    Iodine is essential for thyroid hormone synthesis, and iodine deficiency may result in thyroid disorders including goiter and hypothyroidism. Patients on long-term enteral nutrition (EN) or parenteral nutrition (PN) may be at risk for micronutrient deficiencies. The recommended daily allowance for iodine intake is 150 μg for nonpregnant adults. However, there is no current consensus among scientific societies regarding the quantity of iodine to be added in adult EN and PN formulations. The objective of this study was to determine the iodine content of U.S. adult enteral and parenteral nutrition solutions. This study also aimed to determine whether adult patients in the United States who are receiving long-term artificial nutrition may be at risk for iodine deficiency. Ten enteral nutrition solutions and 4 parenteral nutrition solutions were evaluated. The iodine contents of these solutions were measured spectrophotometrically and compared to the labeled contents. Measured and labeled EN iodine contents were similar (range 131-176 μg/L and 106-160 μg/L, respectively). In contrast, PN formulas were found to contain small, unlabeled amounts of iodine, averaging 27 μg/L. Typical fluid requirements are 30 to 40 mL/kg/day for adults receiving either total EN (TEN) or total PN (TPN). Adults on long-term TEN likely consume enough servings to meet their daily iodine requirements. However, patients on long-term TPN would require on average 5.6 L PN/day to meet the recommended daily allowance of iodine. This volume of PN is far in excess of typical consumption. Thus, U.S. patients requiring long-term TPN may be at risk for iodine deficiency. EN = enteral nutrition; PN = parenteral nutrition; TEN = total enteral nutrition; TPN = total parenteral nutrition; UIC = urinary iodine concentration.

  10. An epidemiological survey of children's iodine nutrition and goitre status in regions with mildly excessive iodine in drinking water in Hebei Province, China.

    PubMed

    Lv, Shengmin; Zhao, Jun; Xu, Dong; Chong, Zhenshui; Chong, Zhengshui; Jia, Lihui; Du, Yonggui; Ma, Jing; Rutherford, Shannon

    2012-07-01

    To identify children's iodine nutrition and goitre status in areas with mildly excessive iodine in drinking water. A cross-sectional survey. Probability proportional to size sampling was employed to randomly select children from thirty townships where the median iodine content in drinking water ranged from 150 to 300 μg/l; their urinary iodine concentrations were determined and their thyroid volumes were measured by ultrasound. Drinking water samples and salt samples from the villages where the children lived were collected using a systematic sampling method. Hebei Province of China. A total of 1259 children aged 8-10 years (621 boys and 638 girls). Children's median urinary iodine concentration was found to be 418·8 μg/l, and the iodine concentration was >300 μg/l for 68·3 % (248/363) of the urine samples. Children's median urinary iodine concentration in villages with median salt iodine >10 mg/kg was significantly higher than that in villages with median salt iodine <5 mg/kg (442·9 μg/l v. 305·4 μg/l, P ≈ 0). The goitre rate of 1259 children examined by ultrasound was 10·96 %. The iodine intake of children living in areas with mildly excessive iodine in drinking water in Hebei Province was found to be excessive. The measured iodine excess in the sampled children is exacerbated by consumption of iodized salt. Goitre was identified in these areas; however, due to the limitation of the current criteria for children's thyroid volume, a comprehensive assessment of the prevalence of goitre in these regions could not be made and further study is required.

  11. Assessment of DNA double-strand breaks induced by intravascular iodinated contrast media following in vitro irradiation and in vivo, during paediatric cardiac catheterization.

    PubMed

    Gould, Richard; McFadden, Sonyia L; Horn, Simon; Prise, Kevin M; Doyle, Philip; Hughes, Ciara M

    2016-01-01

    Paediatric cardiac catheterizations may result in the administration of substantial amounts of iodinated contrast media and ionizing radiation. The aim of this work was to investigate the effect of iodinated contrast media in combination with in vitro and in vivo X-ray radiation on lymphocyte DNA. Six concentrations of iodine (15, 17.5, 30, 35, 45, and 52.5 mg of iodine per mL blood) represented volumes of iodinated contrast media used in the clinical setting. Blood obtained from healthy volunteers was mixed with iodinated contrast media and exposed to radiation doses commonly used in paediatric cardiac catheterizations (0 mGy, 70 mGy, 140 mGy, 250 mGy and 450 mGy). Control samples contained no iodine. For in vivo experimentation, pre and post blood samples were collected from children undergoing cardiac catheterization, receiving iodine concentrations of up to 51 mg of iodine per mL blood and radiation doses of up to 400 mGy. Fluorescence microscopy was performed to assess γH2AX-foci induction, which corresponded to the number of DNA double-strand breaks. The presence of iodine in vitro resulted in significant increases of DNA double-strand breaks beyond that induced by radiation for ≥ 17.5 mg/mL iodine to blood. The in vivo effects of contrast media on children undergoing cardiac catheterization resulted in a 19% increase in DNA double-strand breaks in children receiving an average concentration of 19 mg/mL iodine to blood. A larger investigation is required to provide further information of the potential benefit of lowering the amount of iodinated contrast media received during X-ray radiation investigations. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Distribution of Iodine and Its Geochronological Implications for Gas Field Brine in Japan

    NASA Astrophysics Data System (ADS)

    Tomaru, H.; Hirose, N.; Miyazato, S.

    2017-12-01

    Global distribution of iodine is very heterogeneous in location and chemical species; 65% of total iodine is produced in Chile as solid nitrate (e.g. caliche) and 30% in Japan as solute mainly in gas field brine. In the latter case, because iodine has a close association with marine organic materials such as algae, iodine had been liberated into the surrounding aqueous phase during the generation of oil and gas and traveled together with oil/gas to the current deposit. The distribution of iodine therefore reflects the environments of accumulation and secondary migration of iodine during its diagenetic processes. Here we present the concentrations of total iodine (127-I) and a long-lived radioisotope (129-I) in gas field brines in Japan to understand the behavior of iodine in response to the development of present geological setting including oil field in terms of its geochronological signals using 129-I. The concentrations of iodine dissolved in gas field brines and hot/cold springs in nearby areas are relatively high compared with the seawater composition, although the chloride concentrations are lower than the seawater. This is due to the delivery of iodine from organic-rich sediments into the current deposits. The 129-I has decayed since the deposition of iodine-rich organic materials from the seawater following the standard decay curve, however, the129-I concentrations are relatively low compared with the age of host sediments of the fluids, which indicates iodine has derived secondary from old sediments responsible for the generation of gas. The 129-I and halogen composition also indicate these fluids mix with pre-anthropogenic seawater during the migration. These results characterize the history of long-term migration of iodine in organic-rich marine system.

  13. An assessment of the effectiveness of iodine prophylaxis in pregnant women--analysis in one of reference gynaecological-obstetric centres in Poland.

    PubMed

    Zygmunt, Arkadiusz; Adamczewski, Zbigniew; Zygmunt, Agnieszka; Adamczewska, Katarzyna; Trofimiuk-Muldner, Małgorzata; Hubalewska-Dydejczyk, Alicja; Karbownik-Lewińska, Małgorzata; Lewiński, Andrzej

    2015-01-01

    Iodine deficiency in pregnant women, even of a mild degree, may have adverse effects on both the mother and the foetus. Despite the obligatory model of functioning iodine prophylaxis in Poland, the iodine supply in women during pregnancy and physiological lactation is insufficient. Therefore, those groups should take additional iodine supplementation at a dose of 150-200 μg/day. The aim of this study was to examine the effectiveness of iodine prophylaxis in pregnant women in Poland. The assessment of iodine supply, urine iodine concentration (UIC) in the spot urine sample, as well as levels of TSH, fT4, thyroid antibodies, and thyroid volume, was performed at one time point in 115 women (7 in the 1st trimester, 61 in the 2nd trimester, and 47 in the 3rd trimester). Only 45.2% of women were taking additional amounts of iodine at any time of pregnancy, and the median ioduria was 79.6 μg/L, which pointed to an insufficient supply of iodine. The percentage of women using iodine supplementation increased with the length of pregnancy, which indicates that the recommendations are implemented too late. In women who took iodine supplementation, ioduria was significantly higher than in those not applying iodine supplementation (median 129.4 μg/L vs. 73.0 μg/L; p < 0.001); however, this was still below recommended values. The effectiveness of iodine prophylaxis in pregnant women in Poland, evaluated on the basis of the analysis of randomly chosen sample, is not satisfactory in terms of compliance with the recommendations and, possibly, the quality of supplementation.

  14. Values of iodine metabolism biomarkers in assessing the iodine nutrition status in surgically treated patients with thyroid disease.

    PubMed

    Han, Jian-hua; Wu, Lian; Yu, Song-lin; Fang, Hui-ling; Kamg, Wei-ming; Cheng, Xin-qi; Lu, Jie; Yu, Jian-chun; Qiu, Ling

    2015-04-01

    To assess the clinical application value of iodine metabolism biomarkers in assessing iodine nutrition status in surgically treated patients with thyroid disease. Blood,morning urine and 24-hour urine samples were collected in 31 healthy volunteers and in 30 surgically treated patients with thyroid disease before and after surgery. Iodine concentration was analyzed by inductively coupled plasma mass spectrometry. The iodine metabolism biomarkers including serum iodine (SI), morning urine iodine(UI), morning urine iodine/urine creatinine ratio (UI/UCr), 24-hour urine iodine (24 h UI), and 24-hour urine iodine excretion (24 h UIE) were evaluated in these two groups. In addition, the validation coincidence rate of iodine metabolism biomarkers in healthy volunteers to different reference ranges including World Health Organization, Mayo Clinic, and Quest Diagnostics were calculated. The UI/UCr ratio of pre-operative thyroid disease patients was significantly lower than that of healthy volunteers (P<0.05), while the other biomarkers showed no significant differences (all P>0.05) between these two groups. The SI, UI ,and 24 h UI in postoperative thyroid disease patients were significantly higher than those of the pre-operative patients (all P<0.05). Though the medians of all biomarkers in healthy volunteers were within the reference ranges,only the validation coincidence rates of SI, UI, and UI/UCr in the 41-70-year populations were over than 90% according to Mayo Clinic; furthermore, the area under the receiver operating characteristic curve about UI/UCr ratio (0.737) was the biggest within the iodine metabolism biomarkers. The UI/UCr ratio may be used for iodine nutrition evaluation in surgically treated patients with thyroid disease.

  15. Iodine status in the Nordic countries - past and present.

    PubMed

    Nyström, Helena Filipsson; Brantsæter, Anne Lise; Erlund, Iris; Gunnarsdottir, Ingibjörg; Hulthén, Lena; Laurberg, Peter; Mattisson, Irene; Rasmussen, Lone Banke; Virtanen, Suvi; Meltzer, Helle Margrete

    2016-01-01

    Adequate iodine nutrition is dependent on ground water content, seafood, and, as many countries use iodized cow fodder, dairy products. In most countries, salt fortification programs are needed to assure adequate iodine intake. The objectives are threefold: 1) to describe the past and present iodine situation in the Nordic countries, 2) to identify important gaps of knowledge, and 3) to highlight differences among the Nordic countries' iodine biomonitoring and fortification policies. Historical data are compared with the current situation. The Nordic countries' strategies to achieve recommended intake and urine iodine levels and their respective success rates are evaluated. In the past, the iodine situation ranged from excellent in Iceland to widespread goiter and cretinism in large areas of Sweden. The situation was less severe in Norway and Finland. According to a 1960 World Health Organization (WHO) report, there were then no observations of iodine deficiency in Denmark. In Sweden and Finland, the fortification of table salt was introduced 50-75 years ago, and in Norway and Finland, the fortification of cow fodder starting in the 1950s helped improve the population's iodine status due to the high intake of milk. In Denmark, iodine has been added to household salt and salt in bread for the past 15 years. The Nordic countries differ with regard to regulations and degree of governmental involvement. There are indications that pregnant and lactating women, the two most vulnerable groups, are mildly deficient in iodine in several of the Nordic countries. The Nordic countries employ different strategies to attain adequate iodine nutrition. The situation is not optimal and is in need of re-evaluation. Iodine researchers, Nordic national food administrations, and Nordic governmental institutions would benefit from collaboration to attain a broader approach and guarantee good iodine health for all.

  16. Lifestyle factors related to iodine intakes in French adults.

    PubMed

    Valeix, Pierre; Faure, Patrice; Péneau, Sandrine; Estaquio, Carla; Hercberg, Serge; Bertrais, Sandrine

    2009-12-01

    To assess dietary iodine intakes among adults and to investigate the relationships of dietary, lifestyle, demographic and geographical characteristics with dietary iodine status. Adequacy of iodine intakes was also assessed. Cross-sectional study. Linear regression analyses and logistic regression modelling were used to determine correlates of iodine intakes. Usual iodine mean intake was calculated by averaging six 24 h dietary records completed over a 2-year period. Females aged 35-60 years (n 2962) and males aged 45-60 years (n 2117) living in France and who participated in the SU.VI.MAX study. Iodine intakes ranged from 30.0 to 446.3 microg/d. The median iodine intake was 150.7 microg/d for males and 131.4 microg/d for females. High-level (97.5th percentile) intakes were 273.4 microg/d for males and 245.0 microg/d for females. Overall, 8.5 % of males and 20.3 % of females had intakes <100 microg/d (P < 0.001). Alcohol drinkers and smokers tended to have lower iodine intakes than abstainers or non-smokers. Regular physical activity and both intermediate and high education levels were associated with a lower risk of iodine intake of <150 microg/d. For both males and females there were significant overall regional differences (P < 0.001) in multivariate-adjusted iodine intakes, with higher adjusted iodine intakes in Brittany and Normandy than in the north-eastern region. Our data show a borderline low iodine intake in this middle-aged French population. However, differences in iodine intakes may contribute to explaining only a small part of the effects of sex and age on thyroid disease incidence.

  17. Users manual and modeling improvements for axial turbine design and performance computer code TD2-2

    NASA Technical Reports Server (NTRS)

    Glassman, Arthur J.

    1992-01-01

    Computer code TD2 computes design point velocity diagrams and performance for multistage, multishaft, cooled or uncooled, axial flow turbines. This streamline analysis code was recently modified to upgrade modeling related to turbine cooling and to the internal loss correlation. These modifications are presented in this report along with descriptions of the code's expanded input and output. This report serves as the users manual for the upgraded code, which is named TD2-2.

  18. An Object-Oriented Approach to Writing Computational Electromagnetics Codes

    NASA Technical Reports Server (NTRS)

    Zimmerman, Martin; Mallasch, Paul G.

    1996-01-01

    Presently, most computer software development in the Computational Electromagnetics (CEM) community employs the structured programming paradigm, particularly using the Fortran language. Other segments of the software community began switching to an Object-Oriented Programming (OOP) paradigm in recent years to help ease design and development of highly complex codes. This paper examines design of a time-domain numerical analysis CEM code using the OOP paradigm, comparing OOP code and structured programming code in terms of software maintenance, portability, flexibility, and speed.

  19. Iodine Intake Estimation from the Consumption of Instant Noodles, Drinking Water and Household Salt in Indonesia

    PubMed Central

    Sutrisna, Aang; Knowles, Jacky; Basuni, Abas; Menon, Ravi; Sugihantono, Anung

    2018-01-01

    The objective of this study was to assess the contribution of iodine intake from iodised household salt, iodised salt in instant noodles, and iodine in ground water in five regions of Indonesia. Secondary data analysis was performed using the 2013 Primary Health Research Survey, the 2014 Total Diet Study, and data from food industry research. Iodine intake was estimated among 2719 children, 10–12 years of age (SAC), 13,233 women of reproductive age (WRA), and 578 pregnant women (PW). Combined estimated iodine intake from the three stated sources met 78%, 70%, and 41% of iodine requirements for SAC, WRA and PW, respectively. Household salt iodine contributed about half of the iodine requirements for SAC (49%) and WRA (48%) and a quarter for PW (28%). The following variations were found: for population group, the percentage of estimated dietary iodine requirements met by instant noodle consumption was significantly higher among SAC; for region, estimated iodine intake was significantly higher from ground water for WRA in Java, and from household salt for SAC and WRA in Kalimantan and Java; and for household socio-economic status (SES), iodine intake from household salt was significantly higher in the highest SES households. Enforcement of clear implementing regulations for iodisation of household and food industry salt will promote optimal iodine intake among all population groups with different diets. PMID:29517995

  20. Iodine Intake Estimation from the Consumption of Instant Noodles, Drinking Water and Household Salt in Indonesia.

    PubMed

    Sutrisna, Aang; Knowles, Jacky; Basuni, Abas; Menon, Ravi; Sugihantono, Anung

    2018-03-08

    The objective of this study was to assess the contribution of iodine intake from iodised household salt, iodised salt in instant noodles, and iodine in ground water in five regions of Indonesia. Secondary data analysis was performed using the 2013 Primary Health Research Survey, the 2014 Total Diet Study, and data from food industry research. Iodine intake was estimated among 2719 children, 10-12 years of age (SAC), 13,233 women of reproductive age (WRA), and 578 pregnant women (PW). Combined estimated iodine intake from the three stated sources met 78%, 70%, and 41% of iodine requirements for SAC, WRA and PW, respectively. Household salt iodine contributed about half of the iodine requirements for SAC (49%) and WRA (48%) and a quarter for PW (28%). The following variations were found: for population group, the percentage of estimated dietary iodine requirements met by instant noodle consumption was significantly higher among SAC; for region, estimated iodine intake was significantly higher from ground water for WRA in Java, and from household salt for SAC and WRA in Kalimantan and Java; and for household socio-economic status (SES), iodine intake from household salt was significantly higher in the highest SES households. Enforcement of clear implementing regulations for iodisation of household and food industry salt will promote optimal iodine intake among all population groups with different diets.

  1. Maternal iodine status and neonatal thyroid-stimulating hormone concentration: a community survey in Songkhla, southern Thailand.

    PubMed

    Jaruratanasirikul, Somchit; Sangsupawanich, Pasuree; Koranantakul, Ounjai; Chanvitan, Prasin; Ruaengrairatanaroj, Prasit; Sriplung, Hutcha; Patanasin, Thanomjit; Sukmee, Siriporn

    2009-12-01

    To determine iodine intake and urinary iodine excretion (UIE) in a group of pregnant Thai women and the concentration of thyroid-stimulating hormone (TSH) in their neonates. A prospective cohort study. Three districts of Songkhla, southern Thailand. Two hundred and thirty-six pregnant women. A quarter of the participants lacked knowledge of iodine and the prevention of iodine deficiency, although 70 % used iodized salt. Those who did not use iodized salt stated that they had no knowledge about iodine (57 %) and no iodized salt was sold in their village (36 %). The median iodine intake in the three districts was 205-240 microg/d, with 53-74 % of pregnant women having iodine intake <250 microg/d. The median UIE in the three districts was 51-106 microg/l, with 24-35 % having UIE < 50 microg/l. The mean neonatal TSH was 2.40 (sd 1.56) mU/l, with 8.9 % of neonates having TSH > 5 mU/l. The studied women and their fetuses were at risk of mild iodine deficiency. About a quarter of the participants lacked knowledge of the importance of iodine. Education regarding the importance of iodine supplements and the promotion of iodized salt should be added to national health-care policies in order to prevent iodine-deficiency disorders, diseases that are subclinical but have long-term sequelae.

  2. [Study on the iodine nutrition and iodine deficiency disorders status in pasturing areas of Tibet-a non-epidemic area of iodine deficiency disorders in serious iodine deficiency district].

    PubMed

    DU, Dan; Li, Su-Mei; Li, Xiu-Wei; Wang, Hai-Yan; Li, Shu-Hua; Nima, Cangjue; Danzeng, Sangbu; Zhuang, Guang-Xiu

    2010-08-01

    To explore the status of iodine nutrition and iodine deficiency disorders in the pasturing areas and agricultural regions in Tibet. 30 families were selected respectively in pastoral Dangxiong county and agricultural Qushui county of Lasa. Drinking water and edible salt were collected for testing the iodine contents. In each type of the following populations including children aged 8 - 10, women of child-bearing age and male adults, 50 subjects were randomly sampled to examine their urinary iodine contents. Among them, 50 children and 50 women were randomly selected for goiter examination by palpation. Water iodine content was less than 2 µg/L, both in pasturing area and in agricultural areas. There was no iodized salt used in the families of pasturing areas, while 90% people consumed iodized salt in agricultural areas. The median of urinary iodine in pasturing area was 50.2 µg/L, significantly lower than that of agricultural area (193.2 µg/L). However, the goiter rate of children and women in pasturing area was significantly lower than that in agricultural area. Although iodine intake of populations in pasturing area of Tibet was severely deficient, there was no epidemic of Iodine Deficiency Disorders. This phenomenon noticed by the researchers deserved further investigation.

  3. 21 CFR 862.1640 - Protein-bound iodine test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Protein-bound iodine test system. 862.1640 Section... Systems § 862.1640 Protein-bound iodine test system. (a) Identification. A protein-bound iodine test system is a device intended to measure protein-bound iodine in serum. Measurements of protein-bound...

  4. 21 CFR 862.1640 - Protein-bound iodine test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Protein-bound iodine test system. 862.1640 Section... Systems § 862.1640 Protein-bound iodine test system. (a) Identification. A protein-bound iodine test system is a device intended to measure protein-bound iodine in serum. Measurements of protein-bound...

  5. 21 CFR 862.1640 - Protein-bound iodine test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Protein-bound iodine test system. 862.1640 Section... Systems § 862.1640 Protein-bound iodine test system. (a) Identification. A protein-bound iodine test system is a device intended to measure protein-bound iodine in serum. Measurements of protein-bound...

  6. 21 CFR 862.1640 - Protein-bound iodine test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Protein-bound iodine test system. 862.1640 Section... Systems § 862.1640 Protein-bound iodine test system. (a) Identification. A protein-bound iodine test system is a device intended to measure protein-bound iodine in serum. Measurements of protein-bound...

  7. Injection of iodine to the stratosphere

    NASA Astrophysics Data System (ADS)

    Saiz-Lopez, Alfonso; Baidar, Sunil; Cuevas, Carlos A.; Koening, Theodore; Fernandez, Rafael P.; Dix, Barbara; Kinnison, Douglas E.; Lamarque, Jean-Francois; Rodriguez-Lloveras, Xavier; Campos, Teresa L.; Volkamer, Rainer

    2016-04-01

    There are still many uncertainties about the influence of iodine chemistry in the stratosphere, as the real amount of reactive iodine injected to this layer the troposphere and the partitioning of iodine species are still unknown. In this work we report a new estimation of the injection of iodine into the stratosphere based on novel daytime (SZA < 45°) aircraft observations in the tropical tropopause layer (TORERO campaign) and a 3D global chemistry-climate model (CAM-Chem) with the most recent knowledge about iodine photochemistry. The results indicate that significant levels of total reactive iodine (0.25-0.7 pptv), between 2 and 5 times larger than the accepted upper limits, could be injected into the stratosphere via tropical convective outflow. At these iodine levels, modelled iodine catalytic cycles account for up to 30% of the contemporary ozone loss in the tropical lower stratosphere and can exert a stratospheric ozone depletion potential equivalent or even larger than that of very short-lived bromocarbons. Therefore, we suggest that iodine sources and chemistry need to be considered in assessments of the historical and future evolution of the stratospheric ozone layer.

  8. [Determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry].

    PubMed

    Lin, Li; Chen, Guang; Chen, Yuhong

    2011-07-01

    A method was established for the determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP/ MS). Alkaline extraction and IC-ICP/MS were applied as the sample pre-treatment method and the detection technique respectively, for iodate and iodide determination. Moreover, high-temperature pyrolysis absorption was adopted as the pre-treatment method for total iodine analysis, which finally converted all the iodine species into iodide and measured the iodide by IC-ICP/MS. The recoveries of iodine for alkaline extraction and high-temperature pyrolysis absorption were 89.6%-97.5% and 95.2%-111.2%, respectively. The results were satisfactory. The detection limit of iodine was 0.010 mg/kg. The iodine and its speciation contents in several kinds of plant samples such as seaweeds, kelp, cabbage, tea leaf and spinach were investigated. It was shown that the iodine in seaweeds mainly existed as organic iodine; while the ones in kelp, cabbage, tea leaf and spinach mainly existed as inorganic iodine.

  9. Biofilm formation and control in a simulated spacecraft water system - Three year results

    NASA Technical Reports Server (NTRS)

    Schultz, John R.; Flanagan, David T.; Bruce, Rebekah J.; Mudgett, Paul D.; Carr, Sandra E.; Rutz, Jeffrey A.; Huls, M. H.; Sauer, Richard L.; Pierson, Duane L.

    1992-01-01

    Two simulated spacecraft water systems are being used to evaluate the effectiveness of iodine for controlling microbial contamination within such systems. An iodine concentration of about 2.0 mg/L is maintained in one system by passing ultrapure water through an iodinated ion exchange resin. Stainless steel coupons with electropolished and mechanically-polished sides are being used to monitor biofilm formation. Results after three years of operation show a single episode of significant bacterial growth in the iodinated system when the iodine level dropped to 1.9 mg/L. This growth was apparently controlled by replacing the iodinated ion exchange resin, thereby increasing the iodine level. The second batch of resin has remained effective in controlling microbial growth down to an iodine level of 1.0 mg/L. SEM indicates that the iodine has impeded but may have not completely eliminated the formation of biofilm. Metals analyses reveal some corrosion in the iodinated system after 3 years of continuous exposure. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

  10. Computer Description of the Field Artillery Ammunition Supply Vehicle

    DTIC Science & Technology

    1983-04-01

    Combinatorial Geometry (COM-GEOM) GIFT Computer Code Computer Target Description 2& AfTNACT (Cmne M feerve shb N ,neemssalyan ify by block number) A...input to the GIFT computer code to generate target vulnerability data. F.a- 4 ono OF I NOV 5S OLETE UNCLASSIFIED SECUOITY CLASSIFICATION OF THIS PAGE...Combinatorial Geometry (COM-GEOM) desrription. The "Geometric Information for Tarqets" ( GIFT ) computer code accepts the CO!-GEOM description and

  11. Uptake and distribution of organo-iodine in deep-sea corals.

    PubMed

    Prouty, Nancy G; Roark, E Brendan; Mohon, Leslye M; Chang, Ching-Chih

    2018-07-01

    Understanding iodine concentration, transport, and bioavailability is essential in evaluating iodine's impact to the environment and its effectiveness as an environmental biogeotracer. While iodine and its radionuclides have proven to be important tracers in geologic and biologic studies, little is known about transport of this element to the deep sea and subsequent uptake in deep-sea coral habitats. Results presented here on deep-sea black coral iodine speciation and iodine isotope variability provides key information on iodine behavior in natural and anthropogenic environments, and its geochemical pathway in the Gulf of Mexico. Organo-iodine is the dominant iodine species in the black corals, demonstrating that binding of iodine to organic matter plays an important role in the transport and transfer of iodine to the deep-sea corals. The identification of growth bands captured in high-resolution scanning electron images (SEM) with synchronous peaks in iodine variability suggest that riverine delivery of terrestrial-derived organo-iodine is the most plausible explanation to account for annual periodicity in the deep-sea coral geochemistry. Whereas previous studies have suggested the presence of annual growth rings in deep-sea corals, this present study provides a mechanism to explain the formation of annual growth bands. Furthermore, deep-sea coral ages based on iodine peak counts agree well with those ages derived from radiocarbon ( 14 C) measurements. These results hold promise for developing chronologies independent of 14 C dating, which is an essential component in constraining reservoir ages and using radiocarbon as a tracer of ocean circulation. Furthermore, the presence of enriched 129 I/ 127 I ratios during the most recent period of skeleton growth is linked to nuclear weapons testing during the 1960s. The sensitivity of the coral skeleton to record changes in surface water 129 I composition provides further evidence that iodine composition and isotope variability captured in proteinaceous deep-sea corals is a promising geochronometer as well as an emerging tracer for continental material flux. Published by Elsevier Ltd.

  12. Uptake and distribution of organo-iodine in deep-sea corals

    USGS Publications Warehouse

    Prouty, Nancy G.; Roark, E. Brendan; Mohon, Leslye M.; Chang, Ching-Chih

    2018-01-01

    Understanding iodine concentration, transport, and bioavailability is essential in evaluating iodine's impact to the environment and its effectiveness as an environmental biogeotracer. While iodine and its radionuclides have proven to be important tracers in geologic and biologic studies, little is known about transport of this element to the deep sea and subsequent uptake in deep-sea coral habitats. Results presented here on deep-sea black coral iodine speciation and iodine isotope variability provides key information on iodine behavior in natural and anthropogenic environments, and its geochemical pathway in the Gulf of Mexico. Organo-iodine is the dominant iodine species in the black corals, demonstrating that binding of iodine to organic matter plays an important role in the transport and transfer of iodine to the deep-sea corals. The identification of growth bands captured in high-resolution scanning electron images (SEM) with synchronous peaks in iodine variability suggest that riverine delivery of terrestrial-derived organo-iodine is the most plausible explanation to account for annual periodicity in the deep-sea coral geochemistry. Whereas previous studies have suggested the presence of annual growth rings in deep-sea corals, this present study provides a mechanism to explain the formation of annual growth bands. Furthermore, deep-sea coral ages based on iodine peak counts agree well with those ages derived from radiocarbon (14C) measurements. These results hold promise for developing chronologies independent of 14C dating, which is an essential component in constraining reservoir ages and using radiocarbon as a tracer of ocean circulation. Furthermore, the presence of enriched 129I/127I ratios during the most recent period of skeleton growth is linked to nuclear weapons testing during the 1960s. The sensitivity of the coral skeleton to record changes in surface water 129I composition provides further evidence that iodine composition and isotope variability captured in proteinaceous deep-sea corals is a promising geochronometer as well as an emerging tracer for continental material flux.

  13. Measurements and Modelling of Reactive Iodine Oxides in the Coastal MBL

    NASA Astrophysics Data System (ADS)

    Najera, J. J.; Bloss, W. J.

    2012-04-01

    The release of iodine compounds into the marine atmosphere can affect a number of aspects of atmospheric composition: Iodine species can participate in catalytic ozone destruction cycles, which may be augmented by bromine species; reactions of iodine compounds can perturb the OH:HO2 and NO:NO2 ratios, heterogeneous loss of reservoir compounds such as HOI and INO3 can lead to removal of HOx and NOx, and higher iodine oxides can contribute to the formation and/or growth of aerosol particles. In this work, we focus upon understanding the effect of the spatial distribution of iodine emissions upon local HOx and NOx levels in the immediate vicinity of a coastal sites, using new observations to re-evaluate previous field campaign data. We present an analysis of results from a new instruments which measures point inorganic iodine species concentrations. The technique of resonance fluorescence (RF) is employed for the detection of iodine atoms, and the total photolabile iodine content. Measurements made at Mace Head, Ireland during July-August 2007 and May 2011 are presented. A detailed 1-dimensional photochemical box model is employed in a lagrangian sense to simulate the evolving chemical composition of an air column advected across the coastal margin. The model is compared with the observed iodine species, and then used to explore the transient response of the NOx and HOx families at the Mace Head site to heterogeneous iodine emissions: The transit time between the intertidal iodine emission zone and the shoreline site where previous measurements of HOx, NOx etc. have been made is insufficient for steady-state to become established, although this assumption has been used in earlier model studies of such data. Finally, we consider the limitations in our ability to quantify the impacts of iodine chemistry, which arise from uncertainties in the iodine kinetics and photochemistry - for example, what is the atmospheric lifetime of inorganic iodine ? - and explore their consequences for field measurement - model comparisons.

  14. NIKOS II - A System For Non-Invasive Imaging Of Coronary Arteries With Synchrotron Radiation

    NASA Astrophysics Data System (ADS)

    Dix, Wolf-Rainer; Engelke, Klaus; Heuer, Joachim; Graeff, Walter; Kupper, Wolfram; Lohmann, Michael; Makin, I.; Moechel, Thomas; Reumann, Reinhold

    1989-10-01

    Aim of the work is the visualization of coronary arteries down to 1 mm diameter with an iodine mass density of 1 mg/cm , thus allowing non-invasive investigations by intravenous injection of the contrast agent. Digital Subtraction Angiography (DSA) in energy subtraction mode (dichromography) is employed for this purpose. The two images Cor subtraction are taken at photon energies just below and above the iodine K-edge (33.17 keV). After subtraction the background contrast - such as bone and soft tissue - is suppressed and the iodinated structures are strongly enhanced because of the abrupt change of absorption at the edge. The two monoenergetic beams (bandwidth about 250 eV) with high intensity (about 1011 photons/mm /s) are only available if synchrotron radiation is used. In HASYLAB at DESY (Hamburg, FRG) the system NIKOS was developed for dichromography. It consists of six main parts: A wiggler beam line, a monochromator which filters the two 12 cm wide beams out of the white synchrotron radiation beam, a fast scanning device, a fast low-noise two-line detector, a safety system and a computer system. At present, one scan (two images) lasts 1 s. The images from the in-vivo investigations of dogs have been promising. The right coronary artery (diameter 1.5 mm) was clearly visible.

  15. Influence of fused aromatic ring on the stability of charge transfer complex between iodine and some five membered heterocyclic molecules through ultrasonic and spectral studies

    NASA Astrophysics Data System (ADS)

    Ulagendran, V.; Balu, P.; Kannappan, V.; Kumar, R.; Jayakumar, S.

    2017-08-01

    The charge transfer (CT) interaction between two fused heterocyclic compounds with basic pyrrole group as donors, viz., indole (IND) and carbazole (CAR), and iodine (acceptor) in DMSO medium is investigated by ultrasonic and UV-visible spectral methods at 303 K. The formation of CT complex in these systems is established from the trend in acoustical and excess thermo acoustical properties with molar concentration. The frequency acoustic spectra (FAS) is also carried out on these two systems for two fixed concentrations 0.002 M and 0.02 M, and in the frequency range 1 MHz-10 MHz to justify the frequency chosen for ultrasonic study. The absorption coefficient values in solution are computed and discussed. The formation constants of these complexes are determined using Kannappan equation in ultrasonic method. The formation of 1:1 complexes between iodine and IND, CAR was established by the theory of Benesi - Hildebrand in the UV-visible spectroscopic method. The stability constants of the CT complexes determined by spectroscopic and ultrasonic methods show a similar trend. These values also indicate that the presence of fused aromatic ring influences significantly when compared with K values of similar CT complexes of parent five membered heterocyclic compound (pyrrole) reported by us earlier.

  16. 48 CFR 252.227-7013 - Rights in technical data-Noncommercial items.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... causing a computer to perform a specific operation or series of operations. (3) Computer software means computer programs, source code, source code listings, object code listings, design details, algorithms... or will be developed exclusively with Government funds; (ii) Studies, analyses, test data, or similar...

  17. 48 CFR 252.227-7013 - Rights in technical data-Noncommercial items.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... causing a computer to perform a specific operation or series of operations. (3) Computer software means computer programs, source code, source code listings, object code listings, design details, algorithms... or will be developed exclusively with Government funds; (ii) Studies, analyses, test data, or similar...

  18. 48 CFR 252.227-7013 - Rights in technical data-Noncommercial items.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... causing a computer to perform a specific operation or series of operations. (3) Computer software means computer programs, source code, source code listings, object code listings, design details, algorithms... or will be developed exclusively with Government funds; (ii) Studies, analyses, test data, or similar...

  19. 48 CFR 252.227-7013 - Rights in technical data-Noncommercial items.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... causing a computer to perform a specific operation or series of operations. (3) Computer software means computer programs, source code, source code listings, object code listings, design details, algorithms... developed exclusively with Government funds; (ii) Studies, analyses, test data, or similar data produced for...

  20. Antenna pattern study, task 2

    NASA Technical Reports Server (NTRS)

    Harper, Warren

    1989-01-01

    Two electromagnetic scattering codes, NEC-BSC and ESP3, were delivered and installed on a NASA VAX computer for use by Marshall Space Flight Center antenna design personnel. The existing codes and certain supplementary software were updated, the codes installed on a computer that will be delivered to the customer, to provide capability for graphic display of the data to be computed by the use of the codes and to assist the customer in the solution of specific problems that demonstrate the use of the codes. With the exception of one code revision, all of these tasks were performed.

  1. Iodine in diet

    MedlinePlus

    ... products also contain iodine. Other good sources are plants grown in iodine-rich soil. Side Effects Lack ... daily recommendations by eating seafood, iodized salt, and plants grown in iodine-rich soil. When buying salt ...

  2. A review of the iodine status of UK pregnant women and its implications for the offspring

    PubMed Central

    Bath, Sarah C.; Rayman, Margaret P.

    2015-01-01

    Iodine, as a component of the thyroid hormones, is crucial for brain development and is therefore especially important during pregnancy when the brain is developing most rapidly. While randomised controlled trials of pregnant women in regions of severe iodine deficiency have shown that prenatal iodine deficiency causes impaired cognition, less is known of the effects in regions of mild deficiency. This is relevant to the UK as the World Health Organisation now classifies the UK as mildly iodine deficient, based on a national study of 14-15 year old schoolgirls in 2011. We have previously published a study, using samples and data from the UK-based Avon Longitudinal Study of Parents and Children (ALSPAC) that found an association between low iodine status in early pregnancy (urinary iodine-to-creatinine ratio < 150 μg/g) and lower verbal IQ and reading scores in the offspring. Though the women in ALSPAC were recruited in the early 1990s, the results of the study are still relevant as their iodine status was similar to that reported in recent studies of UK pregnant women. This review discusses the evidence that mild-to-moderate iodine deficiency during pregnancy has deleterious effects on child neurodevelopment and relates that evidence to the data on iodine status in the UK. It has highlighted a need for nationwide data on iodine status of pregnant women and that a randomised controlled trial of iodine supplementation in pregnant women in a region of mild-to-moderate iodine deficiency with child outcomes as the primary endpoint is required. PMID:25663363

  3. A review of the iodine status of UK pregnant women and its implications for the offspring.

    PubMed

    Bath, Sarah C; Rayman, Margaret P

    2015-08-01

    Iodine, as a component of the thyroid hormones, is crucial for brain development and is therefore especially important during pregnancy when the brain is developing most rapidly. While randomised controlled trials of pregnant women in regions of severe iodine deficiency have shown that prenatal iodine deficiency causes impaired cognition, less is known of the effects in regions of mild deficiency. This is relevant to the UK as the World Health Organisation now classifies the UK as mildly iodine deficient, based on a national study of 14-15 year old schoolgirls in 2011. We have previously published a study using samples and data from the UK-based Avon Longitudinal Study of Parents and Children (ALSPAC) that found an association between low iodine status in early pregnancy (urinary iodine-to-creatinine ratio <150 μg/g) and lower verbal IQ and reading scores in the offspring. Though the women in ALSPAC were recruited in the early 1990s, the results of the study are still relevant as their iodine status was similar to that reported in recent studies of UK pregnant women. This review discusses the evidence that mild-to-moderate iodine deficiency during pregnancy has deleterious effects on child neurodevelopment and relates that evidence to the data on iodine status in the UK. It has highlighted a need for nationwide data on iodine status of pregnant women and that a randomised controlled trial of iodine supplementation in pregnant women in a region of mild-to-moderate iodine deficiency with child outcomes as the primary endpoint is required.

  4. Post-production losses in iodine concentration of salt hamper the control of iodine deficiency disorders: a case study in northern Ethiopia.

    PubMed

    Shawel, Dawit; Hagos, Seifu; Lachat, Carl K; Kimanya, Martin E; Kolsteren, Patrick

    2010-06-01

    Iodine is essential for good function of the thyroid, and its deficiency is of public-health importance in Ethiopia. Iodization of salt is an effective and sustainable strategy to prevent and control iodine deficiency in large populations. The effectiveness of salt-iodization programmes depends on the conservation of iodine concentration in salt at various stages of the supply-chain. The overall objective of the study was to assess the loss of iodine in salt from production to consumption and to estimate the proportion of adults, especially pregnant women, at risk of dietary iodine insufficiency. A cross-sectional study was conducted during February-April 2007 in northern Ethiopia. Iodine concentrations of salt samples from producers (n=41), retailers (n=7), and consumers (n=32) were determined using iodiometric titration. A risk assessment was conducted for dietary iodine insufficiency among adults, including pregnant women, using a semi-probabilistic approach. The concentration of iodine in the sampled salts decreased by 57% from the production site to the consumers. The assessment of exposure showed that adults in 63% (n=20) of the households, including 90% (n=29) with pregnant women, were at risk of insufficient iodine intake. A monitoring and evaluation system needs to be established to ensure adequate supply of iodine along the distribution chain. Special attention is needed for the retailers and consumers. At these levels, dissemination of information regarding proper storage and handling of iodized salt is necessary to address the reported loss of iodine from salt.

  5. Availability and Use of Medical Isotopes in Canada - Performed as part of a Radiological Terrorism Risk Assessment

    DTIC Science & Technology

    2004-12-01

    placenta localization 1. Chromic chloride 2. Chromium disodium edetate 3. Labeled human serum albumin 4. Sodium chromate labeled red blood cells...orally 4. Iodinated fibrinogen, i.v. or in vitro 5. Iodinated human serum albumin (IHSA) 6. Iodinated levothyroxine , i.v. or in vitro 7...Iodinated liothyronine, in vitro 8. Iodinated povidone, i.v. 9. Iodinated rose Bengal, i.v. 10. Sodium iodide, orally or i.v. 5. 0.74 MBq (0.02 mCi

  6. Dry method for recycling iodine-loaded silver zeolite

    DOEpatents

    Thomas, Thomas R.; Staples, Bruce A.; Murphy, Llewellyn P.

    1978-05-09

    Fission product iodine is removed from a waste gas stream and stored by passing the gas stream through a bed of silver-exchanged zeolite until the zeolite is loaded with iodine, passing dry hydrogen gas through the bed to remove the iodine and regenerate the bed, and passing the hydrogen stream containing the hydrogen iodide thus formed through a lead-exchanged zeolite which adsorbs the radioactive iodine from the gas stream and permanently storing the lead-exchanged zeolite loaded with radioactive iodine.

  7. Flyer Target Acceleration and Energy Transfer at its Collision with Massive Targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borodziuk, S.; Kasperczuk, A.; Pisarczyk, T.

    2006-01-15

    Numerical modelling was aimed at simulation of successive events resulting from interaction of laser beam-single and double targets. It was performed by means of the 2D Lagrangian hydrodynamics code ATLANT-HE. This code is based on one-fluid and two-temperature model of plasma with electron and ion heat conductivity considerations. The code has an advanced treatment of laser light propagation and absorption. This numerical modelling corresponds to the experiment, which was carried out with the use of the PALS facility. Two types of planar solid targets, i.e. single massive Al slabs and double targets consisting of 6 {mu}m thick Al foil andmore » Al slab were applied. The targets were irradiated by the iodine laser pulses of two wavelengths: 1.315 and 0.438 {mu}m. A pulse duration of 0.4 ns and a focal spot diameter of 250 {mu}m at a laser energy of 130 J were used. The numerical modelling allowed us to obtain a more detailed description of shock wave propagation and crater formation.« less

  8. The Urine Iodine to Creatinine as an Optimal Index of Iodine During Pregnancy in an Iodine Adequate Area in China.

    PubMed

    Li, Chenyan; Peng, Shiqiao; Zhang, Xiaomei; Xie, Xiaochen; Wang, Danyang; Mao, Jinyuan; Teng, Xiaochun; Shan, Zhongyan; Teng, Weiping

    2016-03-01

    Iodine nutrition is a global event, especially for pregnant women. To develop applicable index of iodine intake for population during pregnancy. From 2012 to 2014, pregnant women at less than 8 weeks of gestation (n = 222) and reproductive-age women (n = 827) participated in this study. The pregnant women were evaluated at follow-up visits at 8, 12, 16, 20, 28, and 36 weeks of gestation and 3 and 6 months postpartum. Twenty-four-hour urine samples were collected at weeks 8 of gestation. Urine iodine (UI) and creatinine (Cr) and serum thyroglobulin were measured in all of the subjects. Circulatory iodine was measured using inductively coupled plasma-mass spectrometry at 8, 20, and 36 weeks of gestation and 6 months postpartum. The median UI concentration decreased from 183.6 to 104.2 μg/L during pregnancy. The serum iodine (SI) changes were similar to the UI to creatinine ratio (UI/Cr). The SI level was lowest at the eighth week of gestation (60.5 μg/L), which rose significantly until 20 weeks (106.5 μg/L) and then began to decline (36 wk, 84.7 μg/L). The 24-hour UI excretion measurement was regarded as the gold standard. The area under the receiver-operating characteristic curve for UI/Cr was 0.92 for iodine deficiency diagnoses and 0.78 for SI. The area for SI was 0.82 for excessive iodine diagnoses and 0.75 for UI/Cr. The areas under these curves were significantly different (P < .001). The areas under the receiver-operating characteristic curve for UI were 0.61 (P = .11) and 0.65 (P = .08) for iodine deficiency and excessive iodine diagnoses, respectively. Additionally, for thyroglobulin, these values were 0.54 (P = .53) and 0.53 (P = .74), respectively. Iodine intake, as assessed by spot UI concentration in pregnant women, is inaccurate and increases the prevalence of iodine deficiency. The UI/Cr better reflects the 24-hour iodine excretion and circulating iodine levels during pregnancy and the postpartum period.

  9. [Iodinated contrast media and iodine allergy: myth or reality?].

    PubMed

    Meunier, B; Joskin, J; Damas, F; Meunier, P

    2013-09-01

    The term "iodine allergy" is an old phrase that refers to a reaction to iodinated contrast media. After a brief review of definitions, pathophysiological mechanisms and risk factors of this clinical entity, management is urged immediate and delayed according to the most recent recommendations from the literature. We underline that iodine allergy, as such, does not really exist.

  10. MRI and CT contrast media extravasation

    PubMed Central

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  11. Normal Auger spectra of iodine in gas phase alkali iodide molecules

    NASA Astrophysics Data System (ADS)

    Hu, Zhengfa; Caló, Antonio; Kukk, Edwin; Aksela, Helena; Aksela, Seppo

    2005-06-01

    Molecular normal Auger electron spectra following the iodine 4d ionization in gas-phase alkali iodides were investigated both experimentally and theoretically. The Auger electron spectra for LiI, NaI and KI were recorded using electron impact, and for RbI by using photo-excitation. These Auger spectra were analyzed in detail and compared to the referenced normal Auger spectra of HI [L. Karlsson, S. Svensson, P. Baltzer, M. Carlsson-Göthe, M.P. Keane, A. Naves de Brito, N. Correia, B. Wannberg, J. Phys. B 22 (1989) 3001]. An energy shift toward higher kinetic energy and a narrowing in linewidth are observed in the Auger spectra series revealing the effect of the changing environment from covalently bonded HI to ionic alkali iodide compounds. The experimental results are also compared with the theoretical ab initio calculations and with the Auger spectra of I -, computed with the multiconfiguration Hartree-Fock (MCHF) method.

  12. Measurement of x-ray spectra using a recent YAP(Ce)-MPPC detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Oda, Yasuyuki; Yoshida, Sohei; Yamaguchi, Satoshi; Sato, Yuichi; Ishii, Tomotaka; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya

    2017-09-01

    To measure X-ray spectra with high count rates, we developed a detector consisting of a cerium-doped yttrium aluminum perovskite [YAP(Ce)] crystal and a recent multipixel photon counter (MPPC). Scintillation photons are detected using the MPPC, and the photocurrents flowing through the MPPC are converted into voltages and amplified using a high-speed current-voltage (I-V) amplifier. The MPPC bias voltage was set to a value at the pre-Geiger mode to perform zero-dark counting. The event-pulse widths were approximately 200 ns, and the widths were extend to approximately 1 μs. X-ray spectra were measured using a multichannel analyzer (MCA) for pulse-height analysis. The photon energy was roughly determined by the two-point calibration using tungsten K photons and iodine K fluorescence. Using the YAP(Ce)-MPPC detector, first-generation dual-energy computed tomography was accomplished using iodine and gadolinium contrast media.

  13. 48 CFR 252.227-7013 - Rights in technical data-Noncommercial items.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... causing a computer to perform a specific operation or series of operations. (3) Computer software means computer programs, source code, source code listings, object code listings, design details, algorithms... funds; (ii) Studies, analyses, test data, or similar data produced for this contract, when the study...

  14. Parallel Computation of the Jacobian Matrix for Nonlinear Equation Solvers Using MATLAB

    NASA Technical Reports Server (NTRS)

    Rose, Geoffrey K.; Nguyen, Duc T.; Newman, Brett A.

    2017-01-01

    Demonstrating speedup for parallel code on a multicore shared memory PC can be challenging in MATLAB due to underlying parallel operations that are often opaque to the user. This can limit potential for improvement of serial code even for the so-called embarrassingly parallel applications. One such application is the computation of the Jacobian matrix inherent to most nonlinear equation solvers. Computation of this matrix represents the primary bottleneck in nonlinear solver speed such that commercial finite element (FE) and multi-body-dynamic (MBD) codes attempt to minimize computations. A timing study using MATLAB's Parallel Computing Toolbox was performed for numerical computation of the Jacobian. Several approaches for implementing parallel code were investigated while only the single program multiple data (spmd) method using composite objects provided positive results. Parallel code speedup is demonstrated but the goal of linear speedup through the addition of processors was not achieved due to PC architecture.

  15. Evaluation of Iodine Bioavailability in Seaweed Using in Vitro Methods.

    PubMed

    Domínguez-González, M Raquel; Chiocchetti, Gabriela M; Herbello-Hermelo, Paloma; Vélez, Dinoraz; Devesa, Vicenta; Bermejo-Barrera, Pilar

    2017-09-27

    Due to the high levels of iodine present in seaweed, the ingestion of a large amount of this type of food can produce excessive intake of iodine. However, the food after ingestion undergoes different chemistry and physical processes that can modify the amount of iodine that reaches the systemic circulation (bioavailability). Studies on the bioavailability of iodine from food are scarce and indicate that the bioavailable amount is generally lower than ingested. Iodine in vitro bioavailability estimation from different commercialized seaweed has been studied using different in vitro approaches (solubility, dialyzability, and transport and uptake by intestinal cells). Results indicate that iodine is available after gastrointestinal digestion for absorption (bioaccessibility: 49-82%), kombu being the seaweed with the highest bioaccessibility. The incorporation of dialysis cell cultures to elucidate bioavailability modifies the estimation of the amount of iodine that may reach the systemic circulation (dialysis, 5-28%; cell culture, ≤3%). The paper discusses advantages and drawbacks of these methodologies for iodine bioavailability in seaweed.

  16. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2010-03-15

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detectormore » materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam hardening effect. Conclusions: The results showed that a CT system using an energy resolving detector reduces the dose to the patient while maintaining image quality for various breast imaging tasks.« less

  17. User Instructions for the Systems Assessment Capability, Rev. 1, Computer Codes Volume 3: Utility Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Aaberg, Rosanne L.; Lopresti, Charles A.

    2004-09-14

    This document contains detailed user instructions for a suite of utility codes developed for Rev. 1 of the Systems Assessment Capability. The suite of computer codes for Rev. 1 of Systems Assessment Capability performs many functions.

  18. Gestational changes in iodine status in a cohort study of pregnant women from the United Kingdom: season as an effect modifier123

    PubMed Central

    Bath, Sarah C; Furmidge-Owen, Victoria L; Redman, Christopher WG

    2015-01-01

    Background: Iodine is required throughout pregnancy for thyroid hormone production, which is essential for fetal brain development. Studies of iodine status in pregnant women from the United Kingdom (UK) have focused on early gestation (<16 wk). Data on the effect of advancing gestation on urinary iodine excretion are conflicting, with suggestions of both an increase and a decrease. Objectives: The aims were to evaluate iodine status in a cohort of UK pregnant women and to explore how it changes throughout gestation. Design: We used samples and data from 230 UK pregnant women who were recruited to the Selenium in PRegnancy INTervention study. Iodine concentration was measured in spot-urine samples that were collected at ∼12, 20, and 35 wk of gestation; creatinine concentration was also measured to correct for urine dilution. A linear mixed model was used to explore the effect of gestational week on iodine-to-creatinine ratio, with change in season, body mass index, daily milk intake, and maternal age controlled for. Results: The median urinary iodine concentration from urine samples collected at all time points (n = 662) was 56.8 μg/L, and the iodine-to-creatinine ratio was 116 μg/g, thus classifying this cohort as mildly-to-moderately iodine deficient. The median iodine-to-creatinine ratios at 12, 20, and 35 wk were 102.5, 120.0, and 126.0 μg/g, respectively. Only 3% of women were taking iodine-containing prenatal supplements. The iodine-to-creatinine ratio increased with advancing gestation, and there was a significant interaction between gestational week and season (P = 0.026). For a 1-wk increase in gestation, the iodine-to-creatinine ratio increased by a factor of 1.05 (95% CI: 1.02, 1.08) in winter and by a factor of 1.04 (95% CI: 1.00, 1.08) in summer. Conclusions: This group of UK pregnant women was mildly-to-moderately iodine deficient at all trimesters, which is of public health concern. The finding that the iodine-to-creatinine ratio increased over the course of gestation may not be generalizable to populations with different iodine status from ours and merits further investigation. This trial was registered at www.isrctn.com as ISRCTN37927591. PMID:25948667

  19. Status of Iodine Nutrition among Pregnant Women Attending Antenatal Clinic of a Secondary Care Hospital: A Cross-sectional Study from Northern India.

    PubMed

    Kant, Shashi; Haldar, Partha; Lohiya, Ayush; Yadav, Kapil; Pandav, Chandrakant S

    2017-01-01

    Daily requirement of iodine increases during pregnancy making pregnant women a high-risk group for iodine deficiency disorders. The limited available literature shows that even in iodine sufficient population, pregnant women are iodine deficient. The objective of this study is to assess the current iodine nutrition status among pregnant women in Ballabgarh, district Faridabad, Haryana. Pregnant women were recruited from antenatal clinic (ANC) of subdistrict hospital (SDH), Ballabgarh, Haryana. Consecutive sampling strategy was followed to recruit pregnant women, and women of all trimesters were included in the study. Urinary iodine estimation was done using simple microplate method, and salt iodine was estimated using iodometric titration. The study was approved by Institute Ethics Committee, All India Institute of Medical Sciences (AIIMS), New Delhi. Out of the total 1031 pregnant women, 90.9% were using adequately iodized salt. Median (interquartile range [IQR]) salt consumption by the pregnant women was 8.3 (6.7, 11.1) g/day. Median (IQR) urinary iodine concentration (UIC) for the pregnant women was 260 (199, 323) μg/L. Only 13.5% of pregnant women had insufficient iodine intake (UIC <150 μg/L). There was no significant difference in median UIC values by household salt iodine content and across three trimesters of pregnancy. Iodine nutrition status of the pregnant women attending ANC clinic of SDH Ballabgarh was adequate with attainment of universal salt iodization goal of >90% adequately iodized salt coverage in the study population.

  20. Mixed-layered bismuth-oxygen-iodine materials for capture and waste disposal of radioactive iodine

    DOEpatents

    Krumhansl, James L; Nenoff, Tina M

    2013-02-26

    Materials and methods of synthesizing mixed-layered bismuth oxy-iodine materials, which can be synthesized in the presence of aqueous radioactive iodine species found in caustic solutions (e.g. NaOH or KOH). This technology provides a one-step process for both iodine sequestration and storage from nuclear fuel cycles. It results in materials that will be durable for repository conditions much like those found in Waste Isolation Pilot Plant (WIPP) and estimated for Yucca Mountain (YMP). By controlled reactant concentrations, optimized compositions of these mixed-layered bismuth oxy-iodine inorganic materials are produced that have both a high iodine weight percentage and a low solubility in groundwater environments.

  1. ENGINEERING APPLICATIONS OF ANALOG COMPUTERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryant, L.T.; Janicke, M.J.; Just, L.C.

    1963-10-31

    Six experiments from the fields of reactor engineering, heat transfer, and dynamics are presented to illustrate the engineering applications of analog computers. The steps required for producing the analog solution are shown, as well as complete information for duplicating the solution. Graphical results are provided. The experiments include: deceleration of a reactor control rod, pressure variations through a packed bed, reactor kinetics over many decades with thermal feedback, a vibrating system with two degrees of freedom, temperature distribution in a radiating fin, temperature distribution in an infinite slab considering variable thermal properties, and iodine -xenon buildup in a reactor. (M.C.G.)

  2. Hypertensive crisis due to contrast-enhanced computed tomography in a patient with malignant pheochromocytoma.

    PubMed

    Nakano, Sachiko; Tsushima, Yoshito; Taketomi-Takahashi, Ayako; Higuchi, Tetsuya; Amanuma, Makoto; Oriuchi, Noboru; Endo, Keigo

    2011-07-01

    A 63-year-old man underwent computed tomography (CT) using intravenous low-osmolar iodine contrast medium (LOCM) 6 days after undergoing high-dose (131)I-MIBG therapy for metastatic pheochromocytoma. Immediately after the CT examination, his blood pressure increased to 260/160 mmHg (from 179/101 mmHg before the examination). Phentolamine mesilate was administered, and the blood pressure rapidly went back to normal. Although hypertensive crisis after administration of LOCM is rare, this case suggests that high-dose (131)IMIBG therapy may be a risk factor for hypertensive crisis after administration of intravenous LOCM.

  3. Monte Carlo calculated doses to treatment volumes and organs at risk for permanent implant lung brachytherapy

    NASA Astrophysics Data System (ADS)

    Sutherland, J. G. H.; Furutani, K. M.; Thomson, R. M.

    2013-10-01

    Iodine-125 (125I) and Caesium-131 (131Cs) brachytherapy have been used with sublobar resection to treat stage I non-small cell lung cancer and other radionuclides, 169Yb and 103Pd, are considered for these treatments. This work investigates the dosimetry of permanent implant lung brachytherapy for a range of source energies and various implant sites in the lung. Monte Carlo calculated doses are calculated in a patient CT-derived computational phantom using the EGsnrc user-code BrachyDose. Calculations are performed for 103Pd, 125I, 131Cs seeds and 50 and 100 keV point sources for 17 implant positions. Doses to treatment volumes, ipsilateral lung, aorta, and heart are determined and compared to those determined using the TG-43 approach. Considerable variation with source energy and differences between model-based and TG-43 doses are found for both treatment volumes and organs. Doses to the heart and aorta generally increase with increasing source energy. TG-43 underestimates the dose to the heart and aorta for all implants except those nearest to these organs where the dose is overestimated. Results suggest that model-based dose calculations are crucial for selecting prescription doses, comparing clinical endpoints, and studying radiobiological effects for permanent implant lung brachytherapy.

  4. Numerical study of He/CF{sub 3}I pulsed discharge used to produce iodine atom in chemical oxygen-iodine laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Jiao; Wang Yanhui; Wang Dezhen

    2013-04-15

    The pulsed discharge for producing iodine atoms from the alkyl and perfluoroalky iodides (CH{sub 3}I, CF{sub 3}I, etc.) is the most efficient method for achieving the pulse operating mode of a chemical oxygen-iodine laser. In this paper, a one-dimensional fluid model is developed to study the characteristics of pulsed discharge in CF{sub 3}I-He mixture. By solving continuity equation, momentum equation, Poisson equation, Boltzmann equation, and an electric circuit equation, the temporal evolution of discharge current density and various discharge products, especially the atomic iodine, are investigated. The dependence of iodine atom density on discharge parameters is also studied. The resultsmore » show that iodine atom density increases with the pulsed width and pulsed voltage amplitude. The mixture ratio of CF{sub 3}I and helium plays a more significant role in iodine atom production. For a constant voltage amplitude, there exists an optimal mixture ratio under which the maximum iodine atom concentration is achieved. The bigger the applied voltage amplitude is, the higher partial pressure of CF{sub 3}I is needed to obtain the maximum iodine atom concentration.« less

  5. Recent experiences with iodine water disinfection in Shuttle

    NASA Technical Reports Server (NTRS)

    Gibbons, Randall E.; Flanagan, David T.; Schultz, John R.; Sauer, Richard L.; Slezak, Terry N.

    1990-01-01

    Microbial proliferation in the STS potable water system is prevented by maintaining a 2-5 ppm iodine residual. The iodine is added to fuel cell water by an iodinated ion exchange resin in the Microbial Check Valve (MCV). Crew comments indicated excessive iodine in the potable water. To better define the problem, a method of in-flight iodine analysis was developed. Inflight analysis during STS-30 and STS-28 indicated iodine residuals were generally in the 9-13 ppm range. It was determined that the high iodine residual was caused by MCV influent temperatures in excess of 120 F. This is well above the MCV operating range of 65-90 F. The solution to this problem was to develop a resin suitable for the higher temperatures. Since 8 months were required to formulate a MCV resin suitable for the higher temperatures, a temporary solution was necessary. Two additional MCV's were installed on the chilled and ambient water lines leading into the galley to remove the excess iodine. These reduced the iodine residual to 3-4 ppm during STS-33, STS-34, STS-36 and STS-32. A high-temperature resin was formulated and initially flown on STS-31.

  6. Iodinated natural rubber latex: preparation, characterisation & antibacterial activity assessment.

    PubMed

    Tyagi, M; Singh, S; Singh, H

    2000-11-01

    Natural Rubber (NR) in both its latex and dried form was treated with iodine to make it antibacterial in nature. The NR latex was dried and washed, dissolved in toluene, iodinated and cast into films. In a different approach, NR in its latex form (emulsion) was blended with aqueous solution of povidone-iodine complex (PVP-I) and films were cast. Phase separation of PVP-I was observed in the films prepared using NR latex; whereas the film prepared using NR solution in toluene and molecular iodine were homogeneous, transparent light brown. Solubility assessment of the films revealed that unlike pure NR, the iodinated NR failed to go into solution completely. The films obtained from both the approaches were evaluated for release of iodide ions. On immersion in water, PVP-I blended latex did not retain iodine while sustained release of iodide ion was observed in case of dried NR dissolved in toluene and treated with iodine. The FT-IR spectra of the iodinated films revealed that iodine attaches covalently to the double bonds in the isoprene units of NR. The films were also evaluated for their antibacterial properties and it was observed that the films prepared from both the approaches, acquired antimicrobial properties.

  7. Iodine sorption study on the proposed use of Viton A in a shuttle galley water accumulator

    NASA Technical Reports Server (NTRS)

    Gibbons, Randall E.; Schultz, John R.; Sauer, Richard L.

    1988-01-01

    The installation of a Viton A accumulator in the Shuttle galley has been proposed to prevent overpressurization of the hot water supply system. A laboratory study has been conducted to determine if there would be any interaction between the Viton A material and the iodine used to disinfect the water. Coupons of Viton A were exposed for 24 hours to aqueous iodine solutions similar in quality to the Shuttle's potable water. Changes in the iodine residual were monitored to determine the rate of iodine sorption by the coupon. Total organic carbon (TOC) was monitored to determine the rate of desorption of organic materials from the Viton A. The same coupons were then soaked in reagent-grade water for 24 hours, and iodine was monitored to determine the rate of iodine desorption. The coupons were again exposed to iodine solutions for 24 hours and iodine and TOC were monitored. No significant change in the iodine sorption rate was detected between the first and second exposures. A triangle taste test indicated at a 1 percent confidence level that the water exposed to Viton A had a different taste which was less acceptable to the panelists.

  8. Assessment of the iodine concentration in table salt at the production stage in South Africa.

    PubMed Central

    Jooste, Pieter L.

    2003-01-01

    OBJECTIVE: To determine the iodine content of iodized salt at the production stage, to assess the perceptions and knowledge of salt producers about the prevention and control of iodine deficiency, and to examine the internal quality control procedures used during iodization in South Africa. METHOD: Salt samples were collected for iodine analysis by titration from the 12 producers iodizing salt in South Africa. Information on the producers' knowledge of iodine deficiency disorders and on internal quality control was obtained by means of questionnaires. FINDINGS: The legal requirement of 40-60 ppm iodine was met in 30.9% of salt samples; 57.9% contained more than 30 ppm iodine; 34.8% contained under 20 ppm iodine. There were shortcomings in perceptions and knowledge about iodine deficiency disorders and in the internal quality control procedures of a substantial proportion of the producers. CONCLUSION: In order to encourage and support salt producers to achieve optimal iodization there should be an information, education and communication strategy aimed at improving knowledge of iodine deficiency disorders and at raising the standard of internal quality control procedures. External monitoring should continue. PMID:12973644

  9. Use of Iodine to Biofortify and Promote Growth and Stress Tolerance in Crops

    PubMed Central

    Medrano-Macías, Julia; Leija-Martínez, Paola; González-Morales, Susana; Juárez-Maldonado, Antonio; Benavides-Mendoza, Adalberto

    2016-01-01

    Iodine is not considered essential for land plants; however, in some aquatic plants, iodine plays a critical role in antioxidant metabolism. In humans, iodine is essential for the metabolism of the thyroid and for the development of cognitive abilities, and it is associated with lower risks of developing certain types of cancer. Therefore, great efforts are made to ensure the proper intake of iodine to the population, for example, the iodization of table salt. In the same way, as an alternative, the use of different iodine fertilization techniques to biofortify crops is considered an adequate iodine supply method. Hence, biofortification with iodine is an active area of research, with highly relevant results. The agricultural application of iodine to enhance growth, environmental adaptation, and stress tolerance in plants has not been well explored, although it may lead to the increased use of this element in agricultural practice and thus contribute to the biofortification of crops. This review systematically presents the results published on the application of iodine in agriculture, considering different environmental conditions and farming systems in various species and varying concentrations of the element, its chemical forms, and its application method. Some studies report beneficial effects of iodine, including better growth, and changes in the tolerance to stress and antioxidant capacity, while other studies report that the applications of iodine cause no response or even have adverse effects. We suggested different assumptions that attempt to explain these conflicting results, considering the possible interaction of iodine with other trace elements, as well as the different physicochemical and biogeochemical conditions that give rise to the distinct availability and the volatilization of the element. PMID:27602033

  10. Iodine in food- and dietary supplement–composition databases123

    PubMed Central

    Pehrsson, Pamela R; Patterson, Kristine Y; Spungen, Judith H; Wirtz, Mark S; Andrews, Karen W; Dwyer, Johanna T; Swanson, Christine A

    2016-01-01

    The US Food and Drug Administration (FDA) and the Nutrient Data Laboratory (NDL) of the USDA Agricultural Research Service have worked independently on determining the iodine content of foods and dietary supplements and are now harmonizing their efforts. The objective of the current article is to describe the harmonization plan and the results of initial iodine analyses accomplished under that plan. For many years, the FDA’s Total Diet Study (TDS) has measured iodine concentrations in selected foods collected in 4 regions of the country each year. For more than a decade, the NDL has collected and analyzed foods as part of the National Food and Nutrient Analysis Program; iodine analysis is now being added to the program. The NDL recently qualified a commercial laboratory to conduct iodine analysis of foods by an inductively coupled plasma mass spectrometry (ICP-MS) method. Co-analysis of a set of samples by the commercial laboratory using the ICP-MS method and by the FDA laboratory using its standard colorimetric method yielded comparable results. The FDA recently reviewed historical TDS data for trends in the iodine content of selected foods, and the NDL analyzed samples of a limited subset of those foods for iodine. The FDA and the NDL are working to combine their data on iodine in foods and to produce an online database that can be used for estimating iodine intake from foods in the US population. In addition, the NDL continues to analyze dietary supplements for iodine and, in collaboration with the NIH Office of Dietary Supplements, to publish the data online in the Dietary Supplement Ingredient Database. The goal is to provide, through these 2 harmonized databases and the continuing TDS focus on iodine, improved tools for estimating iodine intake in population studies. PMID:27534627

  11. Adequate Iodine Status in New Zealand School Children Post-Fortification of Bread with Iodised Salt

    PubMed Central

    Jones, Emma; McLean, Rachael; Davies, Briar; Hawkins, Rochelle; Meiklejohn, Eva; Ma, Zheng Feei; Skeaff, Sheila

    2016-01-01

    Iodine deficiency re-emerged in New Zealand in the 1990s, prompting the mandatory fortification of bread with iodised salt from 2009. This study aimed to determine the iodine status of New Zealand children when the fortification of bread was well established. A cross-sectional survey of children aged 8–10 years was conducted in the cities of Auckland and Christchurch, New Zealand, from March to May 2015. Children provided a spot urine sample for the determination of urinary iodine concentration (UIC), a fingerpick blood sample for Thyroglobulin (Tg) concentration, and completed a questionnaire ascertaining socio-demographic information that also included an iodine-specific food frequency questionnaire (FFQ). The FFQ was used to estimate iodine intake from all main food sources including bread and iodised salt. The median UIC for all children (n = 415) was 116 μg/L (females 106 μg/L, males 131 μg/L) indicative of adequate iodine status according to the World Health Organisation (WHO, i.e., median UIC of 100–199 μg/L). The median Tg concentration was 8.7 μg/L, which was <10 μg/L confirming adequate iodine status. There was a significant difference in UIC by sex (p = 0.001) and ethnicity (p = 0.006). The mean iodine intake from the food-only model was 65 μg/day. Bread contributed 51% of total iodine intake in the food-only model, providing a mean iodine intake of 35 μg/day. The mean iodine intake from the food-plus-iodised salt model was 101 μg/day. In conclusion, the results of this study confirm that the iodine status in New Zealand school children is now adequate. PMID:27196925

  12. Iodine Nutrition and the Prevalence of Thyroid Disease after Salt Iodization: A Cross-Sectional Survey in Shanghai, a Coastal Area in China

    PubMed Central

    Zou, Shurong; Wu, Fan; Guo, Changyi; Song, Jun; Huang, Cuihua; Zhu, Zhenni; Yu, Huiting; Guo, Yanfei; Lu, Xi; Ruan, Ye

    2012-01-01

    Background Both insufficient and excess iodine may produce thyroid disease. After salt iodization in China, the median urine iodine concentration (UIC) of children aged 8–10 years appeared adequate. However, it is unknown whether dietary changes due to rapid economic development in Shanghai have affected whole population iodine nutrition. Objective To assess dietary iodine intake, UIC and the prevalence of thyroid disease in the general population of Shanghai. Design A cross-sectional survey was conducted with general participants aged 5–69 years (n = 7,904) plus pregnant and lactating women (n = 380 each) selected by stratified multistage sampling. The iodine concentrations in their salt, drinking water and urine were measured. Daily iodine intake was estimated using the total diet study approach. Serum thyroid hormone concentrations and thyroid-related antibodies were measured and thyroid ultrasonography was performed. Results The median iodine concentration in salt was 29.5 mg/kg, and 12.8 µg/L in drinking water. Iodized salt, used by 95.3% of participants, contributed 63.5% of total dietary iodine. Estimated daily iodine intake was 225.96 µg. The median UIC of general participants was 146.7 µg/L; UIC <100 µg/L (iodine insufficiency) was seen in 28.6%; UIC >300 µg/L (iodine excess) in 10.1%. Pregnant women had a median UIC of 135.9 µg/L, with UIC <150 µg/L in 55.4%. Thyroid nodules and subclinical hypothyroidism were found in 27.44% and 9.17%, respectively. Conclusions According to published criteria, the current dietary iodine intake in Shanghai was generally sufficient and safe, but insufficient in pregnant women. Thyroid nodules and subclinical hypothyroidism were the commonest thyroid diseases identified. PMID:22911705

  13. [Iodine intake in Portuguese school children].

    PubMed

    Limbert, Edward; Prazeres, Susana; São Pedro, Márcia; Madureira, Deolinda; Miranda, Ana; Ribeiro, Manuel; Carrilho, Francisco; Jácome de Castro, J; Lopes, Maria Santana; Cardoso, João; Carvalho, Andre; Oliveira, Maria João; Reguengo, Henrique; Borges, Fátima

    2012-01-01

    The aim of the present study was to evaluate iodine intake in portuguese school children in order to inform health authorities of eventual measures to be implemented. Iodine is the key element for thyroid hormone synthesis and its deficiency even mild, as found in other European countries, may have deleterious effects in pregnancy resulting in cognitive problems of offsprings. In Portugal there are no recent data on iodine intake in schoolchildren. 3680 children aged 6-12 years of both sexes, from 78 different schools were studied. Iodine intake was evaluated trough urine iodine (UI) determinations using a colorimetic method. The global median UI value was 105.5 µg/L; the percentage of children with UI <100 µg/L was 47.1%, corresponding to 41% of the studied schools. The percentage of values <50 µg/L was 11.8%. The male gender, the south region of the country and the distribution of milk in school were significantly linked with a higher iodine elimination. Our global results point to a borderline/ mildly insufficient iodine intake in the portuguese school population. However 47% of the children had UI under 100 µg /L. The comparison of our results with the available data from 30 years ago, point to a considerable improvement, due to silent prophylaxis. Male gender, geographical area and milk distribution influenced positively iodine intake.The importance of milk has been referred in numerous papers. The study of UI in the Portuguese school population points to a borderline iodine intake. However, in 47% of children iodine intake was inadequate. Compared with data from the eighties, a considerable increase in iodine elimination was found. Taking into account the potencial deleterious effects of inadequate iodine intake, a global prophylaxis with salt iodization has to be considered.

  14. Total iodine quantification in fluids and tissues from iodine- or iodide-supplemented rats by ion chromatography following microwave-assisted digestion.

    PubMed

    Delgado, Guadalupe; Muñoz-Torres, Carolina; Orozco-Esquivel, Teresa; Anguiano, Brenda; Aceves, Carmen

    2015-03-01

    Iodine is a crucial component of thyroid hormones, and several reports have shown that iodine per se is implicated in the physiopathology of other organs. Innovative ion chromatography detection following a four-step temperature ramp microwave digestion in 25-50 mM nitric acid was developed to measure total iodine in biological fluids and tissue samples from female Sprague-Dawley rats supplemented with 0.05% molecular iodine (I2) or 0.05% potassium iodide (I(-)) in drinking water. The reported method allows the measurement of total iodine with a limit of quantification of 13.7 μg L(-1), recoveries of 96.3-100.3%, and intra- and inter-assay variations, of 3.5% and 7.4% respectively. Analysis of biological fluids showed that after 48 hours, iodine-supplemented animals exhibited significantly higher levels of total iodine in both serum and urine compared with those supplemented with iodide. The half-life of iodine in serum and urine measured over the first 48 h showed similar patterns for both the I2 (7.89 and 7.76 hours) and I(-) (8.27 and 8.90 hours) supplements. Differential uptake patterns were observed in tissues after 6 days of supplements, with I(-) preferentially retained by thyroid, lactating mammary gland, and milk, and a slightly but significantly higher capture of I2 in pituitary, ovary, and virgin mammary gland. We developed a rapid, selective, and accurate digestion method to process fluid and tissue samples that permits reproducible measurements of total iodine by ion chromatography; iodine or iodide supplement show a similar serum and urine half-life, but organ-specific uptake depends on the chemical form of the iodine supplement.

  15. Iodide Residues in Milk Vary between Iodine-Based Teat Disinfectants.

    PubMed

    French, Elizabeth A; Mukai, Motoko; Zurakowski, Michael; Rauch, Bradley; Gioia, Gloria; Hillebrandt, Joseph R; Henderson, Mark; Schukken, Ynte H; Hemling, Thomas C

    2016-07-01

    Majority of iodine found in dairy milk comes from the diet and teat disinfection products used during milking process. The objective of this study was to evaluate the effects of 4 iodine-based teat dips on milk iodide concentrations varying in iodine level (0.25% vs. 0.5%, w/w), normal low viscosity dip versus barrier dip, and application method (dip vs. spray) to ensure safe iodine levels in dairy milk when these products are used. The iodine exposure study was performed during a 2-wk period. The trial farm was purged of all iodine-based disinfection products for 21 d during a prestudy "washout period," which resulted in baseline milk iodide range of 145 to 182 ppb. During the experiment, iodine-based teat dips were used as post-milking teat disinfectants and compared to a non-iodine control disinfectant. Milk iodide residue levels for each treatment was evaluated from composited group samples. Introduction of different iodine-based teat disinfectants increased iodide residue content in milk relative to the control by between 8 and 29 μg/L when averaged across the full trial period. However, residues levels for any treatment remained well below the consumable limit of 500 μg/L. The 0.5% iodine disinfectant increased milk iodide levels by 20 μg/L more compared to the 0.25% iodine. Compared to dip-cup application, spray application significantly increased milk iodide residue by 21 μg/L and utilized approximately 23% more teat dip. This carefully controlled study demonstrated an increase in milk iodide concentrations from iodine disinfectants, but increases were small and within acceptable limits. © 2016 Institute of Food Technologists®

  16. Urine iodine excretion ın patients with euthyroid noduler disease

    PubMed Central

    Cakir, Evrim; Eskioglu, Erdal; Aydin, Yusuf; Ozkan, Selma Karaahmetoglu; Guler, Serdar

    2011-01-01

    BACKGROUND AND OBJECTIVES: Different nutritional and environmental factors are responsible for the pathogenesis of goiter, but iodine deficiency is the most important factor. However, little is known about the natural course of benign thyroid nodules in euthyroid patients over time. Few studies have used ultrasonographic evaluation to address this issue, especially in iodine-deficient areas. In this study, we present the long-term follow-up of benign thyroid nodules in a iodine-deficient area. DESIGN AND SETTING: Cross-sectional study at a tertiary referral center. PATIENTS AND METHODS: This study included 62 randomly selected patients with benign euthyroid nodule. Thyroid volume and nodules were measured with sonography. Iodine intake was estimated by patient diet history and by measuring iodine excretion in spot urine samples. Patients were followed one year. RESULTS: Patients were divided into three groups according to level of urine iodine excretion: Group 1: <50μg/L (severe iodine deficiency group), Group 2: 50-100μg/L (mild iodine deficiency group), Group 3: >100 g/L (iodine sufficient group). The presence of additional disease (hypertension, diabetes mellitus, coronary heart disease, chronic renal failure and a history of any medication for chronic disorder) and smoking rates were significantly higher in first group compared to the second and third group. Among groups, no significant difference was observed in either right or left thyroid lobe volume after one year. A clinically significant increase in nodule volume was observed in the first group, while there was a significant decrease in the second and third group. CONCLUSION: In this study, iodine deficiency was associated with an increase in thyroid nodule volumes. Smoking rates were higher in iodine deficient groups. It is thought that smoking impairs iodine intake or absorption consistent with a previous report. PMID:21422654

  17. Development of a model and computer code to describe solar grade silicon production processes

    NASA Technical Reports Server (NTRS)

    Gould, R. K.; Srivastava, R.

    1979-01-01

    Two computer codes were developed for describing flow reactors in which high purity, solar grade silicon is produced via reduction of gaseous silicon halides. The first is the CHEMPART code, an axisymmetric, marching code which treats two phase flows with models describing detailed gas-phase chemical kinetics, particle formation, and particle growth. It can be used to described flow reactors in which reactants, mix, react, and form a particulate phase. Detailed radial gas-phase composition, temperature, velocity, and particle size distribution profiles are computed. Also, deposition of heat, momentum, and mass (either particulate or vapor) on reactor walls is described. The second code is a modified version of the GENMIX boundary layer code which is used to compute rates of heat, momentum, and mass transfer to the reactor walls. This code lacks the detailed chemical kinetics and particle handling features of the CHEMPART code but has the virtue of running much more rapidly than CHEMPART, while treating the phenomena occurring in the boundary layer in more detail.

  18. Detailed analysis of isotopic ratio of radioactive iodine in surface soil around Fukushima Daiichi Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Miyake, Yasuto; Matsuzaki, Hiroyuki; Fujiwara, Takeshi; Saito, Takumi; Yamagata, Takeyasu; Honda, Maki

    2013-04-01

    In March 2011, there was an accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) and a lot of radionuclides were discharged into the environment, resulting from a powerful earthquake and tsunami. Considering the impact on human health, the radiation dosimetry is the most important for Iodine-131 among radionuclides in the initial stage immediately following the release of radionuclides. However, Iodine-131 cannot be detected after several months owing to its short half-life (8 days). Cesium-137 was also leaked out from the FDNPP and this can be detected now. But this did not identically act with Iodine-131 and be suitable for the reconstruction of Iodine-131 distribution at the initial stage. Since Iodine-129 (half-life: 1.57E7 yrs) can be detected in the future and it act chemically identically with Iodine-131, the reconstruction by Iodine-129 analysis is important. For this reconstruction, it is necessary to know the isotopic ratio of radioactive iodine (129I/131I) released from the FDNPP. In this study, the Iodine-129 concentration was measured by accelerator mass spectrometry (AMS) in several surface soil samples collected around the FDNPP for which the Iodine-131level had already been determined. Soil samples were put into a U8 standard vessel after being roughly homogenized and dried. Then, samples were homogenized again more completely and several grams were taken for Iodine-129 measurement. Each sample was combusted in a quartz tube and outgas was trapped in alkali solution. An aliquot was taken from the trap solution for the determination of the Iodine-127 concentration by inductively coupled plasma mass spectrometry (ICP-MS). The iodine carrier was added to the trap solution, from which the iodine fraction was purified by solvent extraction and back extraction. Finally, silver iodide precipitation was obtained by adding silver nitrate solution. After dried, the precipitation was mixed with niobium powder and pressed into a cathode for the target at the ion source for AMS. 129I-AMS was performed at MALT (Micro Analysis Laboratory, Tandem Accelerator), The University of Tokyo. The Iodine-127 concentration ranged from 0.21 to 17.4 ppm and the surface deposition amount of Iodine-129 was between 11.8 and 6.06E3 mBq/m2 within the 60 km distant from the NPP. Iodine-129 and Iodine-131 data had good linear correlation. However, the distribution of isotopic ratio of soil samples is somewhat asymmetric and this might suggest that this distribution is affected by different distributions, indicating more than two sources.

  19. Contrast-induced encephalopathy following cardiac catheterization.

    PubMed

    Spina, Roberto; Simon, Neil; Markus, Romesh; Muller, David Wm; Kathir, Krishna

    2017-08-01

    To describe the epidemiology, pathophysiology, clinical presentation, and management of contrast-induced encephalopathy (CIE) following cardiac catheterization. CIE is an acute, reversible neurological disturbance directly attributable to the intra-arterial administration of iodinated contrast medium. The PubMed database was searched and all cases in the literature were retrieved and reviewed. 52 reports of CIE following cardiac catheterization were found. Encephalopathy, motor and sensory disturbances, vision disturbance, opthalmoplegia, aphasia, and seizures have been reported. Transient cortical blindness is the most commonly reported neurological syndrome, occurring in approximately 50% of cases. The putative mechanism involves disruption of the blood brain barrier and direct neuronal injury. Contrast-induced transient vasoconstriction has also been implicated. Symptoms typically appear within minutes to hours of contrast administration and resolve entirely within 24-48 hr. Risk factors may include hypertension, diabetes mellitus, renal impairment, the administration of large volumes of iodinated contrast, percutaneous coronary intervention or selective angiography of internal mammary grafts, and previous adverse reaction to iodinated contrast. Characteristic findings on cerebral imaging include cortical and sub-cortical contrast enhancement on computed tomography (CT). Imaging findings in CIE may mimic subarachnoid hemorrhage or cerebral ischemia; the Hounsfield scale on CT and the apparent diffusion coefficient on magnetic resonance imaging (MRI) are useful imaging tools in distinguishing these entities. In some cases, brain imaging is normal. Prognosis is excellent with supportive management alone. CIE tends to recur, although re-challenge with iodinated contrast without adverse effects has been documented. CIE is an important clinical entity to consider in the differential diagnosis of stroke following cardiac catheterization. Given that prognosis is excellent with supportive management only, physicians should be aware of it, and consider it prior to initiating thrombolysis. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. CTA with fluoroscopy image fusion guidance in endovascular complex aortic aneurysm repair.

    PubMed

    Sailer, A M; de Haan, M W; Peppelenbosch, A G; Jacobs, M J; Wildberger, J E; Schurink, G W H

    2014-04-01

    To evaluate the effect of intraoperative guidance by means of live fluoroscopy image fusion with computed tomography angiography (CTA) on iodinated contrast material volume, procedure time, and fluoroscopy time in endovascular thoraco-abdominal aortic repair. CTA with fluoroscopy image fusion road-mapping was prospectively evaluated in patients with complex aortic aneurysms who underwent fenestrated and/or branched endovascular repair (FEVAR/BEVAR). Total iodinated contrast material volume, overall procedure time, and fluoroscopy time were compared between the fusion group (n = 31) and case controls (n = 31). Reasons for potential fusion image inaccuracy were analyzed. Fusion imaging was feasible in all patients. Fusion image road-mapping was used for navigation and positioning of the devices and catheter guidance during access to target vessels. Iodinated contrast material volume and procedure time were significantly lower in the fusion group than in case controls (159 mL [95% CI 132-186 mL] vs. 199 mL [95% CI 170-229 mL], p = .037 and 5.2 hours [95% CI 4.5-5.9 hours] vs. 6.3 hours (95% CI 5.4-7.2 hours), p = .022). No significant differences in fluoroscopy time were observed (p = .38). Respiration-related vessel displacement, vessel elongation, and displacement by stiff devices as well as patient movement were identified as reasons for fusion image inaccuracy. Image fusion guidance provides added value in complex endovascular interventions. The technology significantly reduces iodinated contrast material dose and procedure time. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Source And Sink Of Iodine For Drinking Water

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L.; Flanagan, David T.; Gibbons, Randall E.

    1991-01-01

    Proposed system for controlling concentration of iodine in potable water exploits temperature dependence of equilibrium partition of iodine between solution in water and residence in ion-exchange resin. Used to maintain concentration of iodine sufficient to kill harmful microbes, but not so great to make water unpalatable. Requires little attention, yet controls concentration of iodine more precisely than iodination and deiodination by manual techniques. Conceived for use aboard spacecraft, system has terrestrial applications in regions where water must be kept potable, resupply difficult, and system must operate largely unattended.

  2. Comparison of two computer codes for crack growth analysis: NASCRAC Versus NASA/FLAGRO

    NASA Technical Reports Server (NTRS)

    Stallworth, R.; Meyers, C. A.; Stinson, H. C.

    1989-01-01

    Results are presented from the comparison study of two computer codes for crack growth analysis - NASCRAC and NASA/FLAGRO. The two computer codes gave compatible conservative results when the part through crack analysis solutions were analyzed versus experimental test data. Results showed good correlation between the codes for the through crack at a lug solution. For the through crack at a lug solution, NASA/FLAGRO gave the most conservative results.

  3. Computational Predictions of the Performance Wright 'Bent End' Propellers

    NASA Technical Reports Server (NTRS)

    Wang, Xiang-Yu; Ash, Robert L.; Bobbitt, Percy J.; Prior, Edwin (Technical Monitor)

    2002-01-01

    Computational analysis of two 1911 Wright brothers 'Bent End' wooden propeller reproductions have been performed and compared with experimental test results from the Langley Full Scale Wind Tunnel. The purpose of the analysis was to check the consistency of the experimental results and to validate the reliability of the tests. This report is one part of the project on the propeller performance research of the Wright 'Bent End' propellers, intend to document the Wright brothers' pioneering propeller design contributions. Two computer codes were used in the computational predictions. The FLO-MG Navier-Stokes code is a CFD (Computational Fluid Dynamics) code based on the Navier-Stokes Equations. It is mainly used to compute the lift coefficient and the drag coefficient at specified angles of attack at different radii. Those calculated data are the intermediate results of the computation and a part of the necessary input for the Propeller Design Analysis Code (based on Adkins and Libeck method), which is a propeller design code used to compute the propeller thrust coefficient, the propeller power coefficient and the propeller propulsive efficiency.

  4. The iodized salt programme in Bangalore, India provides adequate iodine intakes in pregnant women and more-than-adequate iodine intakes in their children.

    PubMed

    Jaiswal, Nidhi; Melse-Boonstra, Alida; Sharma, Surjeet Kaur; Srinivasan, Krishnamachari; Zimmermann, Michael B

    2015-02-01

    To compare the iodine status of pregnant women and their children who were sharing all meals in Bangalore, India. A cross-sectional study evaluating demographic characteristics, household salt iodine concentration and salt usage patterns, urinary iodine concentrations (UIC) in women and children, and maternal thyroid volume (ultrasound). Antenatal clinic of an urban tertiary-care hospital, which serves a low-income population. Healthy pregnant women in all trimesters, aged 18-35 years, who had healthy children aged 3-15 years. Median (range) iodine concentrations of household powdered and crystal salt were 55·9 (17·2-65·9) ppm and 18·9 (2·2-68·2) ppm, respectively. The contribution of iodine-containing supplements and multi-micronutrient powders to iodine intake in the families was negligible. Adequately iodized salt, together with small amounts of iodine in local foods, were providing adequate iodine during pregnancy: (i) the overall median (range) UIC in women was 172 (5-1024) µg/l; (ii) the median UIC was >150 µg/l in all trimesters; and (iii) thyroid size was not significantly different across trimesters. At the same time, the median (range) UIC in children was 220 (10-782) µg/l, indicating more-than-adequate iodine intake at this age. Median UIC was significantly higher in children than in their mothers (P=0·008). In this selected urban population of southern India, the iodized salt programme provides adequate iodine to women throughout pregnancy, at the expense of higher iodine intake in their children. Thus we suggest that the current cut-off for median UIC in children indicating more-than-adequate intake, recommended by the WHO/UNICEF/International Council for the Control of Iodine Deficiency Disorders may, need to be reconsidered.

  5. Optimal and safe upper limits of iodine intake for early pregnancy in iodine-sufficient regions: a cross-sectional study of 7190 pregnant women in China.

    PubMed

    Shi, Xiaoguang; Han, Cheng; Li, Chenyan; Mao, Jinyuan; Wang, Weiwei; Xie, Xiaochen; Li, Chenyang; Xu, Bin; Meng, Tao; Du, Jianling; Zhang, Shaowei; Gao, Zhengnan; Zhang, Xiaomei; Fan, Chenling; Shan, Zhongyan; Teng, Weiping

    2015-04-01

    The WHO Technical Consultation recommends urinary iodine concentrations (UIC) from 250 to 499 μg/L as more-than-adequate iodine intake and UIC ≥ 500 μg/L as excessive iodine for pregnant and lactating women, but scientific evidence for this is weak. We investigated optimal and safe ranges of iodine intake during early pregnancy in an iodine-sufficient region of China. Seven thousand one hundred ninety pregnant women at 4-8 weeks gestation were investigated and their UIC, serum thyroid stimulating hormone (TSH), free thyroxine (FT4), thyroid-peroxidase antibody (TPOAb), thyroglobulin antibody (TgAb), and thyroglobulin (Tg) were measured. The prevalence of overt hypothyroidism was lowest in the group with UIC 150-249 μg/L, which corresponded to the lowest serum Tg concentration (10.18 μg/L). Prevalences of subclinical hypothyroidism (2.4%) and isolated hypothyroxinemia (1.7%) were lower in the group with UIC 150-249 μg/L. Multivariate logistic regression indicated that more-than-adequate iodine intake (UIC 250-499 μg/L) and excessive iodine intake (UIC ≥ 500 μg/L) were associated with a 1.72-fold and a 2.17-fold increased risk of subclinical hypothyroidism, respectively. Meanwhile, excessive iodine intake was associated with a 2.85-fold increased risk of isolated hypothyroxinemia. Moreover, the prevalence of TPOAb positivity and TgAb positivity presented a U-shaped curve, ranging from mild iodine deficiency to iodine excess. The upper limit of iodine intake during early pregnancy in an iodine-sufficient region should not exceed UIC 250 μg/L, because this is associated with a significantly high risk of subclinical hypothyroidism, and a UIC of 500 μg/L should not be exceeded, as it is associated with a significantly high risk of isolated hypothyroxinemia.

  6. Iodine intake and status during pregnancy and lactation before and after government initiatives to improve iodine status, in Palmerston North, New Zealand: a pilot study.

    PubMed

    Brough, Louise; Jin, Ying; Shukri, Nurul Husna; Wharemate, Zirsha Roimata; Weber, Janet L; Coad, Jane

    2015-10-01

    Iodine deficiency during pregnancy and lactation may adversely affect fetal and infant development. Two initiatives were introduced in New Zealand to prevent deficiency: (1) mandatory fortification of bread with iodised salt; and (2) provision of a subsidised iodine supplement (150 μg) for all pregnant and breastfeeding women. The aim of this study was to assess iodine intake and status among a self-selecting sample of pregnant and lactating women in Palmerston North, both before and after the two initiatives. Pregnant and breastfeeding women were recruited before (n = 25 and 32; 2009) and after (n = 34 and 36; 2011) the initiatives. Iodine concentration was determined in 24-h urine and breast milk samples using inductively-coupled plasma mass spectrometry. Use of supplements and salt, knowledge of iodine deficiency, and awareness of the initiatives were determined by questionnaire. Median urine iodine concentration (UIC) was higher in 2011 compared with 2009 for both pregnant (85 and 47 μg L(-1) ) and breastfeeding (74 and 34 μg L(-1) ) participants; median UIC were below the cut-offs for adequate iodine status. However, in 2011, the estimated daily iodine intake during pregnancy was 217 μg day(-1) ; 74% of women achieved the Estimated Average Requirement. Knowledge of the initiatives was low, only 28-56% were aware of the need for iodine supplements and only 15-22% were aware of the mandatory addition of iodised salt to bread. Despite initiatives, UIC of these women indicates iodine deficiency, however, dietary intakes appear adequate. Ongoing surveillance of supplement use and iodine status among pregnant and lactating women throughout New Zealand is needed to fully assess the efficacy of the initiatives. Alternative strategies may require evaluation to ensure all women have adequate iodine during pregnancy and breastfeeding. © 2013 John Wiley & Sons Ltd.

  7. Women with high early pregnancy urinary iodine levels have an increased risk of hyperthyroid newborns: the population-based Generation R Study.

    PubMed

    Medici, Marco; Ghassabian, Akhgar; Visser, Willy; de Muinck Keizer-Schrama, Sabine M P F; Jaddoe, Vincent W V; Visser, W Edward; Hooijkaas, Herbert; Hofman, Albert; Steegers, Eric A P; Bongers-Schokking, Jacoba J; Ross, H Alec; Tiemeier, Henning; Visser, Theo J; de Rijke, Yolanda B; Peeters, Robin P

    2014-04-01

    Iodine deficiency during pregnancy results in thyroid dysfunction and has been associated with adverse obstetric and foetal effects, leading to worldwide salt iodization programmes. As nowadays 69% of the world's population lives in iodine-sufficient regions, we investigated the effects of variation in iodine status on maternal and foetal thyroid (dys)function in an iodine-sufficient population. Urinary iodine, serum TSH, free T4 (FT4) and TPO-antibody levels were determined in early pregnancy (13·3 (1·9) week; mean (SD)) in 1098 women from the population-based Generation R Study. Newborn cord serum TSH and FT4 levels were determined at birth. The median urinary iodine level was 222·5 μg/l, indicating an iodine-sufficient population. 30·8% and 11·5% had urinary iodine levels <150 and >500 μg/l, respectively. When comparing mothers with urinary iodine levels <150 vs ≥150 μg/l, and >500 vs ≤500 μg/l, there were no differences in the risk of maternal increased or decreased TSH, hypothyroxinaemia or hyperthyroidism. Mothers with urinary iodine levels >500 μg/l had a higher risk of a newborn with decreased cord TSH levels (5·6 ± 1·4 (mean ± SE) vs 2·1 ± 0·5%, P = 0·04), as well as a higher risk of a hyperthyroid newborn (3·1 ± 0·9 vs 0·6 ± 0·3%, P = 0·02). These mothers had newborns with higher cord FT4 levels (21·7 ± 0·3 vs 21·0 ± 0·1 pm, P = 0·04). Maternal urinary iodine levels <150 μg/l were not associated with newborn thyroid dysfunction. In an iodine-sufficient population, higher maternal urinary iodine levels are associated with an increased risk of a hyperthyroid newborn. © 2013 John Wiley & Sons Ltd.

  8. Iodine status in the Nordic countries – past and present

    PubMed Central

    Nyström, Helena Filipsson; Brantsæter, Anne Lise; Erlund, Iris; Gunnarsdottir, Ingibjörg; Hulthén, Lena; Laurberg, Peter; Mattisson, Irene; Rasmussen, Lone Banke; Virtanen, Suvi; Meltzer, Helle Margrete

    2016-01-01

    Background Adequate iodine nutrition is dependent on ground water content, seafood, and, as many countries use iodized cow fodder, dairy products. In most countries, salt fortification programs are needed to assure adequate iodine intake. Objectives The objectives are threefold: 1) to describe the past and present iodine situation in the Nordic countries, 2) to identify important gaps of knowledge, and 3) to highlight differences among the Nordic countries’ iodine biomonitoring and fortification policies. Design Historical data are compared with the current situation. The Nordic countries’ strategies to achieve recommended intake and urine iodine levels and their respective success rates are evaluated. Results In the past, the iodine situation ranged from excellent in Iceland to widespread goiter and cretinism in large areas of Sweden. The situation was less severe in Norway and Finland. According to a 1960 World Health Organization (WHO) report, there were then no observations of iodine deficiency in Denmark. In Sweden and Finland, the fortification of table salt was introduced 50–75 years ago, and in Norway and Finland, the fortification of cow fodder starting in the 1950s helped improve the population's iodine status due to the high intake of milk. In Denmark, iodine has been added to household salt and salt in bread for the past 15 years. The Nordic countries differ with regard to regulations and degree of governmental involvement. There are indications that pregnant and lactating women, the two most vulnerable groups, are mildly deficient in iodine in several of the Nordic countries. Conclusion The Nordic countries employ different strategies to attain adequate iodine nutrition. The situation is not optimal and is in need of re-evaluation. Iodine researchers, Nordic national food administrations, and Nordic governmental institutions would benefit from collaboration to attain a broader approach and guarantee good iodine health for all. PMID:27283870

  9. Inadequate Iodine Intake in Population Groups Defined by Age, Life Stage and Vegetarian Dietary Practice in a Norwegian Convenience Sample.

    PubMed

    Brantsæter, Anne Lise; Knutsen, Helle Katrine; Johansen, Nina Cathrine; Nyheim, Kristine Aastad; Erlund, Iris; Meltzer, Helle Margrete; Henjum, Sigrun

    2018-02-17

    Inadequate iodine intake has been identified in populations considered iodine replete for decades. The objective of the current study is to evaluate urinary iodine concentration (UIC) and the probability of adequate iodine intake in subgroups of the Norwegian population defined by age, life stage and vegetarian dietary practice. In a cross-sectional survey, we assessed the probability of adequate iodine intake by two 24-h food diaries and UIC from two fasting morning spot urine samples in 276 participants. The participants included children ( n = 47), adolescents ( n = 46), adults ( n = 71), the elderly ( n = 23), pregnant women ( n = 45), ovo-lacto vegetarians ( n = 25), and vegans ( n = 19). In all participants combined, the median (95% CI) UIC was 101 (90, 110) µg/L, median (25th, 75th percentile) calculated iodine intake was 112 (77, 175) µg/day and median (25th, 75th percentile) estimated usual iodine intake was 101 (75, 150) µg/day. According to WHOs criteria for evaluation of median UIC, iodine intake was inadequate in the elderly, pregnant women, vegans and non-pregnant women of childbearing age. Children had the highest (82%) and vegans the lowest (14%) probability of adequate iodine intake according to reported food and supplement intakes. This study confirms the need for monitoring iodine intake and status in nationally representative study samples in Norway.

  10. [Nutrition iodine status in pregnant women in the sanitary district Sierra de Huelva-Andévalo, South of Spain].

    PubMed

    Arrobas-Velilla, Teresa; González-Rodríguez, Concepción; Barco-Sánchez, Antonio; Castaño-López, Miguel; Perea-Carrasco, Rafael; Pascual-Salvador, Elena; Limón-Padilla, J; Marina-Tascón, Elena; Perea-Brenes, M; Sánchez-Mateos, María Aguila; González-Martin, Carmen; Bermúdez-de-la-Vega, José Antonio; Albusac-Aguilar, Rogelio; Fabiani-Romero, Fernando

    2011-01-01

    Iodine is an essential trace element implicated in synthesis of thyroid hormones. Iodine requirements vary throughout life. This iodine requirement is increased during pregnancy and breastfeeding. In a previous study carried out by our group in 2008, we detected an iodine-deficient area in the province of Huelva, specially in district Sierra de Huelva-Andévalo by means of neonatal TSH determinations. To reinforce the iodine supplementation campaign and its impact on their newborns in order to assess nutrition iodine status in pregnant women using questionnaire and ioduria determination. This study has been jointly carried out by Congenital Hypothyroidism Unit of the Clinical Biochemistry Department of the Virgen Macarena University Hospital (Seville) and the Gynecology and Clinical Analysis Unit of the Río Tinto Hospital (Huelva) during two years. We studied 313 pregnant women. All of them filled out a personal questionnaire to know the iodine nutritional status in their area. Ioduria was determinated by high-resolution liquid chromatography. Data from pregnant women and results of the studied variables were analyzed with SPSS v13.0. Pregnant women from the sanitary district Sierra de Huelva-Andévalo present a median for ioduria which corresponds to an insufficient iodine intake according to the WHO classification. The questionnaires suggest that this iodine deficiency is consequence of an insufficient iodine intake and a low adherence to the treatment.

  11. Inadequate Iodine Intake in Population Groups Defined by Age, Life Stage and Vegetarian Dietary Practice in a Norwegian Convenience Sample

    PubMed Central

    Knutsen, Helle Katrine; Johansen, Nina Cathrine; Nyheim, Kristine Aastad; Erlund, Iris; Meltzer, Helle Margrete

    2018-01-01

    Inadequate iodine intake has been identified in populations considered iodine replete for decades. The objective of the current study is to evaluate urinary iodine concentration (UIC) and the probability of adequate iodine intake in subgroups of the Norwegian population defined by age, life stage and vegetarian dietary practice. In a cross-sectional survey, we assessed the probability of adequate iodine intake by two 24-h food diaries and UIC from two fasting morning spot urine samples in 276 participants. The participants included children (n = 47), adolescents (n = 46), adults (n = 71), the elderly (n = 23), pregnant women (n = 45), ovo-lacto vegetarians (n = 25), and vegans (n = 19). In all participants combined, the median (95% CI) UIC was 101 (90, 110) µg/L, median (25th, 75th percentile) calculated iodine intake was 112 (77, 175) µg/day and median (25th, 75th percentile) estimated usual iodine intake was 101 (75, 150) µg/day. According to WHOs criteria for evaluation of median UIC, iodine intake was inadequate in the elderly, pregnant women, vegans and non-pregnant women of childbearing age. Children had the highest (82%) and vegans the lowest (14%) probability of adequate iodine intake according to reported food and supplement intakes. This study confirms the need for monitoring iodine intake and status in nationally representative study samples in Norway. PMID:29462974

  12. Proceduracy: Computer Code Writing in the Continuum of Literacy

    ERIC Educational Resources Information Center

    Vee, Annette

    2010-01-01

    This dissertation looks at computer programming through the lens of literacy studies, building from the concept of code as a written text with expressive and rhetorical power. I focus on the intersecting technological and social factors of computer code writing as a literacy--a practice I call "proceduracy". Like literacy, proceduracy is a human…

  13. Computer Code Aids Design Of Wings

    NASA Technical Reports Server (NTRS)

    Carlson, Harry W.; Darden, Christine M.

    1993-01-01

    AERO2S computer code developed to aid design engineers in selection and evaluation of aerodynamically efficient wing/canard and wing/horizontal-tail configurations that includes simple hinged-flap systems. Code rapidly estimates longitudinal aerodynamic characteristics of conceptual airplane lifting-surface arrangements. Developed in FORTRAN V on CDC 6000 computer system, and ported to MS-DOS environment.

  14. Comparison Study of Subsonic and Transonic Mixing in a Multi-Kw Grid-Nozzle Supersonic Chemical Oxygen Iodine Laser

    NASA Astrophysics Data System (ADS)

    Vyskubenko, Oleg; Sugimoto, Daichi; Watanabe, Goro; Tei, Kazuyoku; Nanri, Kenzo; Fujioka, Tomoo

    2005-05-01

    The present study compares the laser medium properties for subsonic and transonic iodine injection schemes of a multi-kW grid-nozzle supersonic chemical oxygen iodine laser (COIL). Two supersonic nozzles of similar geometry having subsonic or transonic iodine injectors were investigated in the present study. Small signal gain (SSG) and internal cavity temperature (ICT) were experimentally measured as a function of the iodine flow rate and coordinate in the direction of the gas flow. Dissociated fraction of iodine F and the number N of O2(1Δ) molecules consumed for the dissociation of one iodine molecule were estimated by an analytical method, utilizing SSG and ICT as input parameters. Both gain and temperature were measured by diode laser spectroscopy. Pressure broadening of the spectroscopic line of iodine atom was taken into account when calculating the gas temperature in the cavity.

  15. Disinfection susceptibility of waterborne pseudomonads and Legionellae under simulated space vehicle conditions

    NASA Technical Reports Server (NTRS)

    Mcfeters, Gordon A.; Pyle, Barry H.; Watters, Shelley K.; Cargill, Kari L.; Yu, Feipeng P.

    1991-01-01

    The sensitivity of waterborne bacteria from iodinated systems to iodine is examined with particular attention to the recovery of the organisms. The use of iodine as a disinfectant for space-vehicle water is described, and references are made to studies of iodine sensitivity and the relationship between growth rate and iodine sensitivity. Growth following iodination is discussed, and bacterial responses to nutrient restriction are examined for both P aeruginosa and Legionella pneumophila. The low level of organic nutrients in spacecraft water allows the selection for bacteria that are less sensitive to halogens. The formation of biofilms within the water-treatment system enhances bacterial resistance to iodine, and in the case of high-quality water it is shown that sublethal doses of iodine can stimulate bacterial growth. Water treatment should therefore be based on antecedent growth conditions, nutrient limitation, biofilm formation, and ambient selective pressures.

  16. Additional studies for the spectrophotometric measurement of iodine in water

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Previous work in iodine spectroscopy is briefly reviewed. Continued studies of the direct spectrophotometric determination of aqueous iodine complexed with potassium iodide show that free iodine is optimally determined at the isosbestic point for these solutions. The effects on iodine determinations of turbidity and chemical substances (in trace amounts) is discussed and illustrated. At the levels tested, iodine measurements are not significantly altered by such substances. A preliminary design for an on-line, automated iodine monitor with eventual capability of operating also as a controller was analyzed and developed in detail with respect single beam colorimeter operating at two wavelengths (using a rotating filter wheel). A flow-through sample cell allows the instrument to operate continuously, except for momentary stop flow when measurements are made. The timed automatic cycling of the system may be interrupted whenever desired, for manual operation. An analog output signal permits controlling an iodine generator.

  17. Consolidation of tin sulfide chalcogels and xerogels with and without adsorbed iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riley, Brian J.; Pierce, David A.; Lepry, William C.

    Tin sulfide (Sn2S3) chalcogels are one of the most effective non-oxide aerogels evaluated to date for iodine gas capture. This is attributed to the fact that the Sn within the gel network has a strong affinity for chemisorption of iodine to form SnI4. This study demonstrates an approach for consolidating the raw and iodine-sorbed Sn2S3 chalcogels into a chalcogenide glass using GeS2 as a glass forming additive. The system with both iodine-sorbed and iodine-free Sn2S3 chalcogels provides better glass-forming characteristics than Sn-S or Sn-S-I alone, and the quantity of iodine measured in the bulk glass of the consolidated iodine-sorbed Sn2S3more » chalcogel was at ~45 mass%. Additional experiments were also conducted using microwave sintering and hot isostatic pressing with Sn2S3 xerogels.« less

  18. Modeling an Iodine Hall Thruster Plume in the Iodine Satellite (ISAT)

    NASA Technical Reports Server (NTRS)

    Choi, Maria

    2016-01-01

    An iodine-operated 200-W Hall thruster plume has been simulated using a hybrid-PIC model to predict the spacecraft surface-plume interaction for spacecraft integration purposes. For validation of the model, the plasma potential, electron temperature, ion current flux, and ion number density of xenon propellant were compared with available measurement data at the nominal operating condition. To simulate iodine plasma, various collision cross sections were found and used in the model. While time-varying atomic iodine species (i.e., I, I+, I2+) information is provided by HP Hall simulation at the discharge channel exit, the molecular iodine species (i.e., I2, I2+) are introduced as Maxwellian particles at the channel exit. Simulation results show that xenon and iodine plasma plumes appear to be very similar under the assumptions of the model. Assuming a sticking coefficient of unity, iodine deposition rate is estimated.

  19. Modeling an Iodine Hall Thruster Plume in the Iodine Satellite (ISAT)

    NASA Technical Reports Server (NTRS)

    Choi, Maria

    2016-01-01

    An iodine-operated 200-W Hall thruster plume has been simulated using a hybrid-PIC model to predict the spacecraft surface-plume interaction for spacecraft integration purposes. For validation of the model, the plasma potential, electron temperature, ion current flux, and ion number density of xenon propellant were compared with available measurement data at the nominal operating condition. To simulate iodine plasma, various collision cross sections were found and used in the model. While time-varying atomic iodine species (i.e., I, I+, I2+) information is provided by HPHall simulation at the discharge channel exit, the molecular iodine species (i.e., I2, I2+) are introduced as Maxwellian particles at the channel exit. Simulation results show that xenon and iodine plasma plumes appear to be very similar under the assumptions of the model. Assuming a sticking coefficient of unity, iodine deposition rate is estimated.

  20. [Effect of selenium on serum TGAb, TMAb, FT3, FT4 and TSH of rats with excessive intake of iodine].

    PubMed

    Chi, Haiyan; Zhou, Yuping; Li, Li

    2012-07-01

    To investigate the effect of selenium on the TGAb, TMAb, FT3, FT4 and TSH level of rats with excessive intake of iodine. Wistar rats were divided into three groups by random:normal control, high iodine group and high iodine plus selenium group. Rats in the high iodine plus selenium group were lavaged with sodium selenite for 10 weeks. The levels of serum TGAb, TMAb, FT3, FT4 and TSH were tested at different time of the experiment. There were no significant change on levels of FT3, FT4 and TSH (P > 0.05). The levels of TGAb and TMAb in the high iodine group were increased slowly (P < 0.05), but no significant change was observed in the high iodine plus selenium group. Excessive intake of iodine might induce goiter, and selenium might have antagonistic effect on it.

  1. Cloud Computing for Complex Performance Codes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appel, Gordon John; Hadgu, Teklu; Klein, Brandon Thorin

    This report describes the use of cloud computing services for running complex public domain performance assessment problems. The work consisted of two phases: Phase 1 was to demonstrate complex codes, on several differently configured servers, could run and compute trivial small scale problems in a commercial cloud infrastructure. Phase 2 focused on proving non-trivial large scale problems could be computed in the commercial cloud environment. The cloud computing effort was successfully applied using codes of interest to the geohydrology and nuclear waste disposal modeling community.

  2. APC: A New Code for Atmospheric Polarization Computations

    NASA Technical Reports Server (NTRS)

    Korkin, Sergey V.; Lyapustin, Alexei I.; Rozanov, Vladimir V.

    2014-01-01

    A new polarized radiative transfer code Atmospheric Polarization Computations (APC) is described. The code is based on separation of the diffuse light field into anisotropic and smooth (regular) parts. The anisotropic part is computed analytically. The smooth regular part is computed numerically using the discrete ordinates method. Vertical stratification of the atmosphere, common types of bidirectional surface reflection and scattering by spherical particles or spheroids are included. A particular consideration is given to computation of the bidirectional polarization distribution function (BPDF) of the waved ocean surface.

  3. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... therefrom, to human beings or animals. (2) Iodine-131, in units not exceeding 10 microcuries each for use in... location of storage or use, a total amount of iodine-125, iodine-131, selenium-75, cobalt-57 and/or iron-59... authorize manufacture and distribution of iodine-125, iodine-131, carbon-14, hydrogen-3 (tritium), selenium...

  4. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... therefrom, to human beings or animals. (2) Iodine-131, in units not exceeding 10 microcuries each for use in... location of storage or use, a total amount of iodine-125, iodine-131, selenium-75, cobalt-57 and/or iron-59... authorize manufacture and distribution of iodine-125, iodine-131, carbon-14, hydrogen-3 (tritium), selenium...

  5. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... therefrom, to human beings or animals. (2) Iodine-131, in units not exceeding 10 microcuries each for use in... location of storage or use, a total amount of iodine-125, iodine-131, selenium-75, cobalt-57 and/or iron-59... authorize manufacture and distribution of iodine-125, iodine-131, carbon-14, hydrogen-3 (tritium), selenium...

  6. 10 CFR 31.11 - General license for use of byproduct material for certain in vitro clinical or laboratory testing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... therefrom, to human beings or animals. (2) Iodine-131, in units not exceeding 10 microcuries each for use in... location of storage or use, a total amount of iodine-125, iodine-131, selenium-75, cobalt-57 and/or iron-59... authorize manufacture and distribution of iodine-125, iodine-131, carbon-14, hydrogen-3 (tritium), selenium...

  7. Iodine

    USGS Publications Warehouse

    Krukowski, S.T.

    2006-01-01

    In descending order, Chile, Japan and the United States have the largest iodine reserves. Chile produces iodine from iodate minerals while Japan and the United States produce it from sodium iodide solutions found in underground iodide solutions. Iodine is also produced from subterranean brines in Azerbaijan, Russia, Turkmenista, Indonesia and Uzbekistan. In 2005, iodine prices increased sharply to US$19 to US$23 then leveled off at US$23 to US$25.

  8. Iodine deficiency in pregnant women at first trimester in Ankara.

    PubMed

    Koyuncu, Kazibe; Turgay, Batuhan; Söylemez, Feride

    2018-04-27

    Iodine deficiency in pregnant woman in Ankara was shown in previous studies. We aimed to conduct a study in a tertiary center to investigate for the need for iodine replacement in our population. This was a single tertiary center, non-interventional, retrospective, cross-sectional study. Data were retrieved retrospectively from 440 women who had been in first trimester in gestational age. Maternal iodine status, TSH levels, T4 levels were examined. Urinary iodine concentration (UIC) was calculated based on Sandell-Kolthoff reaction which is a colorimetric method. We excluded patients with previous thyroid disease or current thyroid disease. Thyroid hormones and TSH were measured by chemiluminescence immunoassays. Iodine deficiency prevalence (UI <150 μg/L) was 84.7% in first trimester of pregnancy in our population. The median UIC was 81.6 (1-450) μg/L, indicating iodine insufficiency. All the patients declared iodized salt use. None of the patients were taking iodine replacement. The mean TSH level was 1.53±1.27 mIU/l, (0.01 mIU/l-14.74 mIU/l) and mean T4 levels was 12.51±5.01 mIU/l, (7.09 mIU/l, -23.7 mIU/l,). TSH levels of 56 patients were higher than 2.5 mIU/l. According to these results 12.72% of the patients had subclinical hypothyroidism based on serum TSH and Free T4 levels. Isolated hypothyroxinemia was present in one patient. Our study demonstrated that pregnant women still suffer from iodine deficiency in Ankara despite of mandatory iodine salt use. Iodized salt use does not provide enough iodine supplement especially in pregnant women. Iodine supplementation is shown to enhance neurological development and psychomotor performance. We suggest that iodine should be a part of routine laboratory evaluation at the first prenatal visit for its importance in early pregnancy. Also, iodized salt use education should be provided to the women to eradicate iodine deficiency. Iodine supplements should be recommended to all pregnant women in addition to iodized salt.

  9. [Prevalence of thyroid function in pregnant and lactating women in areas with different iodine levels of Shanxi province].

    PubMed

    Ren, Y T; Jia, Q Z; Zhang, X D; Guo, B S; Zhang, F F; Cheng, X T; Wang, Y P

    2018-05-10

    Objective: To investigate the effects of high iodine intake on thyroid function in pregnant and lactating women. Methods: A cross sectional epidemiological study was conducted among 130 pregnant women and 220 lactating women aged 19-40 years in areas with high environment iodine level (>300 μg/L) or proper environment iodine level (50-100 μg/L) in Shanxi in 2014. The general information, urine samples and blood samples of the women surveyed and water samples were collected. The water and urine iodine levels were detected with arsenic and cerium catalysis spectrophotometric method, the blood TSH level was detected with electrochemiluminescence immunoassay, and thyroid stimulating hormone (FT(4)), antithyroid peroxidase autoantibody (TPOAb) and anti-thyroglobulin antibodies (TGAb) were detected with chemiluminescence immunoassay. Results: The median urine iodine levels of the four groups were 221.9, 282.5, 814.1 and 818.6 μg/L, respectively. The median serum FT(4) of lactating women in high iodine area and proper iodine area were 12.96 and 13.22 pmol/L, and the median serum TSH was 2.45 and 2.17 mIU/L, respectively. The median serum FT(4) of pregnant women in high iodine area and proper iodine area were 14.66 and 16.16 pmol/L, and the median serum TSH was 2.13 and 1.82 mIU/L, respectively. The serum FT(4) levels were lower and the abnormal rates of serum TSH were higher in lactating women than in pregnant women in both high iodine area and proper iodine area, the difference was statistically significant (FT(4): Z =-6.677, -4.041, P <0.01; TSH: Z =8.797, 8.910, P <0.01). In high iodine area, the abnormal rate of serum FT(4) in lactating women was higher than that in pregnant women, the difference was statistically significant ( Z =7.338, P =0.007). The serum FT(4) level of lactating women in high iodine area was lower than that in proper iodine area, the difference was statistically significant ( Z =-4.687, P =0.000). In high iodine area, the median serum FT(4) in early pregnancy, mid-pregnancy and late pregnancy was 16.26, 14.22 and 14.80 pmol/L, respectively, and the median serum TSH was 1.74, 1.91 and 2.38 mIU/L, respectively. In high iodine area, the serum FT(4) level in early pregnancy was higher than that in mid-pregnancy and late pregnancy, and the serum TSH level was lower than that in mid-pregnancy and late pregnancy, the difference was statistically significant (FT(4): Z =-2.174, -2.238, P <0.05; TSH: Z =-2.985, -1.978, P <0.05). There were no significant differences in the positive rates of serum thyroid autoantibodies among the four groups of women and women in different periods of pregnancy ( P >0.05). The morbidity rates of subclinical hyperthyroidism in pregnant women and lactating women in high iodine area were obviously higher than those in proper iodine areas, the difference was statistically significant ( χ (2)=5.363, 5.007, P <0.05). Conclusions: Excessive iodine intake might increase the risk of subclinical hypothyroidism in pregnant women and lactating women. It is suggested to strengthen the iodine nutrition and thyroid function monitoring in women, pregnant women and lactating women in areas with high environmental iodine.

  10. Influence of contrast media viscosity and temperature on injection pressure in computed tomographic angiography: a phantom study.

    PubMed

    Kok, Madeleine; Mihl, Casper; Mingels, Alma A; Kietselaer, Bas L; Mühlenbruch, Georg; Seehofnerova, Anna; Wildberger, Joachim E; Das, Marco

    2014-04-01

    Iodinated contrast media (CM) in computed tomographic angiography is characterized by its concentration and, consecutively, by its viscosity. Viscosity itself is directly influenced by temperature, which will furthermore affect injection pressure. Therefore, the purposes of this study were to systematically evaluate the viscosity of different CM at different temperatures and to assess their impact on injection pressure in a circulation phantom. Initially, viscosity of different contrast media concentrations (240, 300, 370, and 400 mgI/mL) was measured at different temperatures (20°C-40°C) with a commercially available viscosimeter. In the next step, a circulation phantom with physical conditions was used. Contrast media were prepared at different temperatures (20°C, 30°C, 37°C) and injected through a standard 18-gauge needle. All other relevant parameters were kept constant (iodine delivery rate, 1.9 g I/s; total amount of iodine, 15 g I). Peak flow rate (in milliliter per second) and injection pressure (psi) were monitored. Differences in significance were tested using the Kruskal-Wallis test (Statistical Package for the Social Sciences). Viscosities for iodinated CM of 240, 300, 370, and 400 mg I/mL at 20°C were 5.1, 9.1, 21.2, and 28.8 mPa.s, respectively, whereas, at 40°C, these were substantially lower (2.8, 4.4, 8.7, and 11.2 mPa.s). In the circulation phantom, mean (SD) peak pressures for CM of 240 mg I/mL at 20°C, 30°C, and 37°C were 107 (1.5), 95 (0.6), and 92 (2.1) psi; for CM of 300 mg I/mL, 119 (1.5), 104 (0.6), and 100 (3.6) psi; for CM of 370 mg I/mL, 150 (0.6), 133 (4.4), and 120 (3.5) psi; and for CM of 400 mg I/mL, 169 (1.0), 140 (2.1), and 135 (2.9) psi, respectively, with all P values less than 0.05. Low concentration, low viscosity, and high temperatures of CM are beneficial in terms of injection pressure. This should also be considered for individually tailored contrast protocols in daily routine scanning.

  11. Status of Iodine Nutrition among Pregnant Women Attending Antenatal Clinic of a Secondary Care Hospital: A Cross-sectional Study from Northern India

    PubMed Central

    Kant, Shashi; Haldar, Partha; Lohiya, Ayush; Yadav, Kapil; Pandav, Chandrakant S.

    2017-01-01

    Background: Daily requirement of iodine increases during pregnancy making pregnant women a high-risk group for iodine deficiency disorders. The limited available literature shows that even in iodine sufficient population, pregnant women are iodine deficient. Objective: The objective of this study is to assess the current iodine nutrition status among pregnant women in Ballabgarh, district Faridabad, Haryana. Materials and Methods: Pregnant women were recruited from antenatal clinic (ANC) of subdistrict hospital (SDH), Ballabgarh, Haryana. Consecutive sampling strategy was followed to recruit pregnant women, and women of all trimesters were included in the study. Urinary iodine estimation was done using simple microplate method, and salt iodine was estimated using iodometric titration. The study was approved by Institute Ethics Committee, All India Institute of Medical Sciences (AIIMS), New Delhi. Results: Out of the total 1031 pregnant women, 90.9% were using adequately iodized salt. Median (interquartile range [IQR]) salt consumption by the pregnant women was 8.3 (6.7, 11.1) g/day. Median (IQR) urinary iodine concentration (UIC) for the pregnant women was 260 (199, 323) μg/L. Only 13.5% of pregnant women had insufficient iodine intake (UIC <150 μg/L). There was no significant difference in median UIC values by household salt iodine content and across three trimesters of pregnancy. Conclusion: Iodine nutrition status of the pregnant women attending ANC clinic of SDH Ballabgarh was adequate with attainment of universal salt iodization goal of >90% adequately iodized salt coverage in the study population. PMID:29184324

  12. Iodine Supplementation for Pediatric Patients Receiving Long-Term Parenteral Nutrition.

    PubMed

    Santoro, Jonathan D; Nespor, Colleen; Poole, Robert L; Kerner, John A

    2016-04-01

    Patients dependent on parenteral nutrition (PN) are among a group at risk of developing iodine deficiency. Supplementation with iodine in this population has been debated in a number of studies, resulting in variable clinical practices. The Committee on Clinical Practice Issues of the American Society for Clinical Nutrition recommends a dose of 1 mcg/kg/d of parenteral iodine for patients receiving PN. At our institution, PN trace elements do not include iodine, although this is not the case internationally. Our study sought to assess iodine levels and thyroid function in a cohort of PN-dependent pediatric patients. A retrospective analysis studied 32 pediatric patients with a variety of medical diagnoses who received PN as a primary means of nutrition for 6 months or longer. Patients received variable proportions of their total caloric intake as PN, which ranged from 14%-100%. Iodine and thyroid function levels were obtained by serum sampling. No patient in our cohort of 32 demonstrated thyroid dysfunction or developed iodine deficiency. The length of time on PN and the percentage of total nutrition intake as PN were not associated with iodine levels (P < .89 and P < .73, respectively). There were no significant associations between age (P < .342), clinical diagnosis (P < .46), or sex (P < .43) on iodine status. There were no incidences of abnormal iodine levels in our cohort. Our study suggests that pediatric patients older than 6 months receiving PN may not benefit from iodine supplementation, but further investigation is needed. © 2015 American Society for Parenteral and Enteral Nutrition.

  13. Mixed-layered bismuth--oxygen--iodine materials for capture and waste disposal of radioactive iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krumhansl, James L; Nenoff, Tina M

    2015-01-06

    Materials and methods of synthesizing mixed-layered bismuth oxy-iodine materials, which can be synthesized in the presence of aqueous radioactive iodine species found in caustic solutions (e.g. NaOH or KOH). This technology provides a one-step process for both iodine sequestration and storage from nuclear fuel cycles. It results in materials that will be durable for repository conditions much like those found in Waste Isolation Pilot Plant (WIPP) and estimated for Yucca Mountain (YMP). By controlled reactant concentrations, optimized compositions of these mixed-layered bismuth oxy-iodine inorganic materials are produced that have both a high iodine weight percentage and a low solubility inmore » groundwater environments.« less

  14. Importance of iodine in pregnancy.

    PubMed

    Carreto-Molina, Nicolás; García-Solís, Pablo; Solís-S, Juan Carlos; Robles-Osorio, Ludivina; Hernández-Montiel, Hebert Luis; Vega-Malagón, Genaro

    2012-09-01

    Iodine is an essential constituent of thyroid hormones (TH). TH actively take part in critical periods of brain development during embryonic, fetal and postnatal stages. Therefore the absence of TH or iodine in these critical periods produces an irreversible brain damage. In fact, it is known that iodine deficiency is the leading cause of preventable brain damage worldwide. Because of the physiological adjustments during pregnancy iodine requirements increase significantly from 150 microg per day in non-pregnant adult women to 250 microg per day. Moreover, recent epidemiological studies around the world show that iodine intake during pregnancy is insufficient in many countries, even in developed countries like Australia, Spain and Italy. In the present work an overview of the importance of iodine nutrition during pregnancy is given.

  15. An age-specific biokinetic model for iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leggett, Richard Wayne

    This study reviews age-specific biokinetic data for iodine in humans and extends to pre-adult ages the baseline parameter values of the author’s previously published model for systemic iodine in adult humans. Compared with the ICRP’s current age-specific model for iodine introduced in Publication 56 (1989), the present model provides a more detailed description of the behavior of iodine in the human body; predicts greater cumulative (integrated) activity in the thyroid for short-lived isotopes of iodine; predicts similar cumulative activity in the thyroid for isotopes with half-time greater than a few hours; and, for most iodine isotopes, predicts much greater cumulativemore » activity in salivary glands, stomach wall, liver, and kidneys.« less

  16. An age-specific biokinetic model for iodine

    DOE PAGES

    Leggett, Richard Wayne

    2017-10-26

    This study reviews age-specific biokinetic data for iodine in humans and extends to pre-adult ages the baseline parameter values of the author’s previously published model for systemic iodine in adult humans. Compared with the ICRP’s current age-specific model for iodine introduced in Publication 56 (1989), the present model provides a more detailed description of the behavior of iodine in the human body; predicts greater cumulative (integrated) activity in the thyroid for short-lived isotopes of iodine; predicts similar cumulative activity in the thyroid for isotopes with half-time greater than a few hours; and, for most iodine isotopes, predicts much greater cumulativemore » activity in salivary glands, stomach wall, liver, and kidneys.« less

  17. Urinary Iodine and Goiter Prevalence in Belarus: Experience of the Belarus–American Cohort Study of Thyroid Cancer and Other Thyroid Diseases Following the Chornobyl Nuclear Accident

    PubMed Central

    Polyanskaya, Olga; McConnell, Robert; Gong, Zhihong; Drozdovitch, Vladimir; Rozhko, Alexander; Prokopovich, Alexander; Petrenko, Sergey; Brenner, Alina; Zablotska, Lydia

    2011-01-01

    Background Because iodine deficiency can influence background rates of thyroid disease or modify radiation dose–response relationships, we compiled descriptive data on iodine status among participants in a Belarusian–American screening study who were exposed in childhood to radioiodine fallout from the Chornobyl nuclear accident. We have used the data from two consecutive screening cycles to examine whether indicators of iodine status changed before and after documented government initiatives to improve iodine intake. Methods Urinary iodine concentrations in spot samples and prevalence of diffuse goiter by palpation were assessed in 11,676 exposed subjects who were 18 years or younger at the time of the accident on April 26, 1986, and were screened beginning 11 years later in connection with the Belarus–American Thyroid Study. Data for the first (January 1997–March 2001) and second (April 2001–December 2004) screening cycles, which largely correspond to time periods before and after official iodination efforts in 2000/2001, were compared for the cohort overall as well as by oblast of residence (i.e., state) and type of residency (urban/rural). Results Median urine iodine levels among cohort members increased significantly in the later period (111.5 μg/L) compared to the earlier (65.3 μg/L), with the cycle 2 level in the range defined as adequate iodine intake by the World Health Organization. During the same period, a significant decline in diffuse goiter prevalence was also observed. In both cycles, urinary iodine levels were lower in rural than in urban residents. Urinary iodine levels, but not rates of goiter, varied by oblast of residence. In both periods, adjusted median urine iodine concentrations were similar in Gomel and Minsk oblasts, where ∼89% of cohort members resided, and were lowest in Mogilev oblast. Yet Mogilev oblast and rural areas showed the most marked increases over time. Conclusions Trends in urinary iodine concentrations and prevalence of diffuse goiter by palpation suggest that iodination efforts in Belarus were successful, with benefits extending to the most iodine-deficient populations. Iodine status should be considered when evaluating thyroid disease risk in radioiodine-exposed populations since it can change over time and may influence rates of disease and, possibly, dose–response relationships. PMID:21323597

  18. The Danish investigation on iodine intake and thyroid disease, DanThyr: status and perspectives.

    PubMed

    Laurberg, Peter; Jørgensen, Torben; Perrild, Hans; Ovesen, Lars; Knudsen, Nils; Pedersen, Inge Bülow; Rasmussen, Lone B; Carlé, Allan; Vejbjerg, Pernille

    2006-08-01

    Denmark was an area of iodine deficiency, and mandatory iodine fortification of table salt and salt in bread (13 p.p.m. iodine) was initiated in 2000/2001. The Danish investigation on iodine intake and thyroid disease (DanThyr) is the monitoring of the iodine fortification program. DanThyr consists of three main parts: a study of population cohorts initialized before (n=4649) and after (n=3570) iodization of salt, a prospective identification of incident cases of overt hyper- and hypothyroidism in a population of around 550,000 people since 1997, and compilation of data from the national registers on the use of thyroid medication, thyroid surgery, and radioiodine therapy. Studies were carried-out in parallel in subcohorts living in areas with differences in iodine content of ground water. The study showed profound effects of even small differences in iodine intake level on the prevalence of goiter, nodules, and thyroid dysfunction. Mild and moderate iodine deficiency was associated with a decrease in serum TSH with age. Other environmental factors were also important for goiter development (increase in risk, smoking and pregnancy; decrease in risk, oral contraception and alcohol consumption), and the individual risk depended on the genetic background. Environmental factors had only a minor influence on the prevalence of thyroid autoantibodies in the population. There were more cases of overt hypothyroidism in mild than in moderate iodine deficiency caused by a 53% higher incidence of spontaneous (presumably autoimmune) hypothyroidism. On the other hand, there were 49% more cases of overt hyperthyroidism in the area with moderate iodine deficiency. The cautious iodine fortification program, aiming at an average increase in iodine intake of 50 mug/day has been associated with a 50% increase in incidence of hyperthyroidism in the area with the most severe iodine deficiency. The incidence is expected to decrease in the future, but there may be more cases of Graves' hyperthyroidism in young people. A number of environmental factors influence the epidemiology of thyroid disorders, and even relatively small abnormalities and differences in the level of iodine intake of a population have profound effects on the occurrence of thyroid abnormalities. Monitoring and adjustment of iodine intake in the population is an important part of preventive medicine.

  19. Uptake of different species of iodine by water spinach and its effect to growth.

    PubMed

    Weng, Huan-Xin; Yan, Ai-Lan; Hong, Chun-Lai; Xie, Lin-Li; Qin, Ya-Chao; Cheng, Charles Q

    2008-08-01

    A hydroponic experiment has been carried out to study the influence of iodine species [iodide (I(-)), iodate (IO(-)(3)), and iodoacetic acid (CH(2)ICOO(-))] and concentrations on iodine uptake by water spinach. Results show that low levels of iodine in the nutrient solution can effectively stimulate the growth of biomass of water spinach. When iodine levels in the nutrient solution are from 0 to 1.0 mg/l, increases in iodine levels can linearly augment iodine uptake rate by the leafy vegetables from all three species of iodine, and the uptake effects are in the following order: CH(2)ICOO(-) >I(-)>IO(-)(3). In addition, linear correlation was observed between iodine content in the roots and shoots of water spinach, and their proportion is 1:1. By uptake of I(-), vitamin C (Vit C) content in water spinach increased, whereas uptake of IO(-)(3) and CH(2)ICOO(-) decreased water spinach Vit C content. Furthermore, through uptake of I(-) and IO(-)(3). The nitrate content in water spinach was increased by different degrees.

  20. Iodine Propulsion Advantages for Low Cost Mission Applications and the Iodine Satellite (ISAT) Technology Demonstration

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.; Schumacher, Daniel M.

    2015-01-01

    The NASA Marshall Space Flight Center Science and Technology Office is continuously exploring technology options to increase performance or reduce cost and risk to future NASA missions including science and exploration. Electric propulsion is a prevalent technology known to reduce mission costs by reduction in launch costs and spacecraft mass through increased post launch propulsion performance. The exploration of alternative propellants for electric propulsion continues to be of interest to the community. Iodine testing has demonstrated comparable performance to xenon. However, iodine has a higher storage density resulting in higher ?V capability for volume constrained systems. Iodine's unique properties also allow for unpressurized storage yet sublimation with minimal power requirements to produce required gas flow rates. These characteristics make iodine an ideal propellant for secondary spacecraft. A range of mission have been evaluated with a focus on low-cost applications. Results highlight the potential for significant cost reduction over state of the art. Based on the potential, NASA has been developing the iodine Satellite for a near-term iodine Hall propulsion technology demonstration. Mission applications and progress of the iodine Satellite project are presented.

  1. Silica-based waste form for immobilization of iodine from reprocessing plant off-gas streams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matyáš, Josef; Canfield, Nathan; Sulaiman, Sannoh

    A high selectivity and sorption capacity for iodine and a feasible consolidation to a durable SiO2-based waste form makes silver-functionalized silica aerogel (Ag0-aerogel) an attractive choice for the removal and sequestration of iodine compounds from the off-gas of a nuclear fuel reprocessing plant. Hot uniaxial pressing of iodine-loaded Ag0-aerogel (20.2 mass% iodine) at 1200°C for 30 min under 29 MPa pressure provided a partially sintered product with residual open porosity of 16.9% that retained ~93% of sorbed iodine. Highly iodine-loaded Ag0-aerogel was successfully consolidated by hot isostatic pressing at 1200°C with a 30-min hold and under 207 MPa. The fullymore » densified waste form had a bulk density of 3.3 g/cm3 and contained ~39 mass% iodine. The iodine was retained in the form of nano- and micro-particles of AgI that were uniformly distributed inside and along boundaries of fused silica grains.« less

  2. Iodine deficiency disorders in Sarawak, Malaysia.

    PubMed

    Kiyu, A; Tambi, Z; Ahmad, Y

    1998-12-01

    The state of Sarawak in Malaysia has a high prevalence of iodine deficiency disorders (IDD). This has been revealed through a review of goitre surveys that were carried out in the State from the early 1970s to the 1990s. The primary cause was low iodine intake. Contributory factors were low iodine content in the soil and water as well as high cassava consumption. Virtual elimination of IDD is one of the nutritional goals of the IDD prevention and control programs. The strategies adopted include the iodination of coarse salt, which is sold in the market by shopkeepers and also provided free from government health clinics; legislation requiring that salt sold in IDD-gazetted areas must be iodised; and the use of iodinators to iodise water supplied by the gravity-feed system to villages and boarding schools in rural areas. The indicators used in the monitoring and evaluation of the program include the availability of iodised salt in the market and households, iodine levels in water supply that had been fitted with iodinators, goitre volume measured by ultrasound, and urinary iodine excretion among school children.

  3. Performance of an iodine-fueled radio-frequency ion-thruster

    NASA Astrophysics Data System (ADS)

    Holste, Kristof; Gärtner, Waldemar; Zschätzsch, Daniel; Scharmann, Steffen; Köhler, Peter; Dietz, Patrick; Klar, Peter J.

    2018-01-01

    Two sets of performance data of the same radio-frequency ion-thruster (RIT) have been recorded using iodine and xenon, respectively, as propellant. To characterize the thruster's performance, we have recorded the radio-frequency DC-power, required for yielding preset values of the extracted ion-beam currents, as a function of mass flow. For that purpose, an iodine mass flow system had to be developed, calibrated, and integrated into a newly-built test facility for studying corrosive propellants. The performance mappings for iodine and xenon differ significantly despite comparable operation conditions. At low mass flows, iodine exhibits the better performance. The situation changes at higher mass flows where the performance of iodine is significantly poorer than that of xenon. The reason is very likely related to the molecular nature of iodine. Our results show that iodine as propellant is compatible with RIT technology. Furthermore, it is a viable alternative as propellant for dedicated space missions. In particular, when taking into account additional benefits such as possible storage as a solid and its low price the use of iodine as propellant in ion thrusters is competitive.

  4. Adsorption of iodine from COIL waste gas on soaked coal-based activated carbon

    NASA Astrophysics Data System (ADS)

    Zhou, Junbo; Hao, Shan; Gao, Liping

    2014-04-01

    The chemical oxygen-iodine laser (COIL) has wide application prospects in military, industrial and medical treatment fields as a second generation gas chemical laser to follow the first HF/DF chemical laser. However, a COIL releases large amounts of gas, such as helium, oxygen, chlorine and iodine. Chlorides have a serious corrosive effect on the system, especially iodine vapor crystallization, which seriously endangers the normal use of vacuum systems, and radioactive methyl iodide, which is hazardous to operators and pollutes the environment. The use of soaked coal-based activated carbon as an adsorbent for removing methyl iodine is proposed, while it is proposed that coal-based activated carbon is an effective adsorbent for removing stable iodine. The research conducted in this work shows that iodine residues are less than 0.5 μg ml-1 after the adsorption treatment and the decontamination factor of the coal-based activated carbon for removing stable iodine is more than 1000. Using this method can achieve the purpose of removing harmful iodine, satisfy the requirements for engineering applications, and also be applied to other nuclear power plant flue gas treatments.

  5. Hypercube matrix computation task

    NASA Technical Reports Server (NTRS)

    Calalo, Ruel H.; Imbriale, William A.; Jacobi, Nathan; Liewer, Paulett C.; Lockhart, Thomas G.; Lyzenga, Gregory A.; Lyons, James R.; Manshadi, Farzin; Patterson, Jean E.

    1988-01-01

    A major objective of the Hypercube Matrix Computation effort at the Jet Propulsion Laboratory (JPL) is to investigate the applicability of a parallel computing architecture to the solution of large-scale electromagnetic scattering problems. Three scattering analysis codes are being implemented and assessed on a JPL/California Institute of Technology (Caltech) Mark 3 Hypercube. The codes, which utilize different underlying algorithms, give a means of evaluating the general applicability of this parallel architecture. The three analysis codes being implemented are a frequency domain method of moments code, a time domain finite difference code, and a frequency domain finite elements code. These analysis capabilities are being integrated into an electromagnetics interactive analysis workstation which can serve as a design tool for the construction of antennas and other radiating or scattering structures. The first two years of work on the Hypercube Matrix Computation effort is summarized. It includes both new developments and results as well as work previously reported in the Hypercube Matrix Computation Task: Final Report for 1986 to 1987 (JPL Publication 87-18).

  6. SUFFICIENT IODINE INTAKE IN SCHOOLCHILDREN FROM THE ZAGREB AREA: ASSESSMENT WITH DRIED BLOD SPOT THYROGLOBULIN AS A NEW FUNCTIONAL BIOMARKER FOR IODINE DEFICIENCY.

    PubMed

    Jukić, Tomislav; Zimmermann, Michael Bruce; Granić, Roko; Prpić, Marin; Krilić, Drazena; Juresa, Vesna; Katalenić, Marijan; Kusić, Zvonko

    2015-12-01

    Current methods for assessment of iodine intake in a population comprise measurements of urinary iodine concentration (UIC), thyroid volume by ultrasound (US-Tvol), and newborn TSH. Serum or dried blood spot thyroglobulin (DBS-Tg) is a new promising functional iodine status biomarker in children. In 1996, a new act on universal salt iodination was introduced in Croatia with 25 mg of potassium iodideper kg of salt. In 2002, Croatia finally reached iodine sufficiency. However, in 2009, median UIC in 101 schoolchildren from Zagreb, the capital of Croatia, was 288 µg/L, posing to be excessive. The aim of the study was to assess iodine intake in schoolchildren from the Zagreb area and to evaluate the value of DBS-Tg in schoolchildren as a new functional biomarker of iodine deficiency (and iodine excess). The study was part of a large international study in 6- to 12-year-old children supported by UNICEF, the Swiss Federal Institute of Technology (ETH Zurich) and the International Council for the Control of Iodine Deficiency Disorders (ICCIDD). According to international study results, the median cut-off Tg < 13 µg/L and/or < 3% Tg values > 40 µg/L indicate iodine sufficiency. The study included 159 schoolchildren (median age 9.1 ± 1.4 years) from Zagreb and a nearby small town of Jastrebarsko with measurements of UIC, US-Tvol, DBS-Tg, T4, TSH and iodine content in salt from households of schoolchildren (KI/kg of salt). Overall median UIC was 205 µg/L (range 1-505 µg/L). Thyroid volumes in schoolchildren measured by US were within the normal range according to reference values. Median DBS-Tg in schoolchildren was 12.1 µg/L with 3% of Tg values > 40 µg/L. High Tg values were in the UIC range < 50 µg/L and > 300 µg/L (U-shaped curve of Tg plotted against UIC). All children were euthyroid with geometric mean TSH 0.7 ± 0.3 mU/L and arithmetic mean T4 62 ± 12.5 nmol/L. The mean KI content per kg of salt was 24.9 ± 3.1 mg/kg (range 19-36 mg/kg). Study results indicated iodine sufficiency in schoolchildren from the Zagreb area. Thyroglobulin proved to be a sensitive indicator of both iodine deficiency and iodine excess in children. Iodine content in salt from households of schoolchildren was in good compliance with the Croatian act (20-30 mg KI/kg of salt).

  7. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions.

    PubMed

    Böhm, Ingrid; Nairz, Knud; Morelli, John N; Keller, Patricia Silva Hasembank; Heverhagen, Johannes T

    2017-04-01

    Purpose  To test the hypothesis that the incomplete diagnosis "iodine allergy" is a possibly dangerous concept for patients under routine radiologic conditions. Materials and Methods  300 patients with a history of an "iodine allergy" were retrospectively screened and compared with two age-, sex-, and procedure-matched groups of patients either diagnosed with a nonspecific "iodine contrast medium (ICM) allergy" or an allergy to a specific ICM agent. For all groups, the clinical symptoms of the most recent past adverse drug reaction (ADR), prophylactic actions taken for subsequent imaging, and ultimate outcome were recorded and analyzed. Results  The diagnosis "iodine allergy" was not otherwise specified in 84.3 % patients. For this group, in most cases, the symptoms of the previous ADRs were not documented. In contrast, the type of ADR was undocumented in only a minority of patients in the comparison groups. In the group of patients with an "iodine allergy" the percentage of unenhanced CT scans was greater than within the other two groups (36.7 % vs. 28.7 %/18.6 %). ADRs following prophylactic measures were only observed in the "iodine allergy" group (OR of 9.24 95 % CI 1.16 - 73.45; p < 0.04). Conclusion  This data confirms the hypothesis that the diagnosis "iodine allergy" is potentially dangerous and results in uncertainty in clinical management and sometimes even ineffective prophylactic measures. Key points   · The term "iodine allergy" is imprecise, because it designates allergies against different substance classes, such as disinfectants with complexed iodine and contrast media containing covalently bound iodine.. · There is a clear correlation between the exactness of the diagnosis - from the alleged "iodine allergy" to "contrast media allergy" to naming the exact culprit CM - and the quality of documentation of the symptoms.. · Management of patients diagnosed with "iodine allergy" was associated with uncertainty leading to unenhanced scans and sometimes unnecessary prophylactic actions.. · The term "iodine allergy" should be omitted, because it is potentially dangerous and can decrease the quality of radiology exams.. Citation Format · Böhm Ingrid, Nairz Knud, Morelli John N et al. Iodinated Contrast Media and the Alleged "Iodine Allergy": An Inexact Diagnosis Leading to Inferior Radiologic Management and Adverse Drug Reactions. Fortschr Röntgenstr 2017; 189: 326 - 332. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Study on characteristics of chirp about Doppler wind lidar system

    NASA Astrophysics Data System (ADS)

    Du, Li-fang; Yang, Guo-tao; Wang, Ji-hong; Yue, Chuan; Chen, Lin-xiang

    2016-11-01

    In the doppler wind lidar, usually every 4MHz frequency error will produce wind error of 1m/s of 532nm laser. In the Doppler lidar system, frequency stabilization was achieved through absorption of iodine molecules. Commands that control the instrumental system were based on the PID algorithm and coded using VB language. The frequency of the seed laser was locked to iodine molecular absorption line 1109 which is close to the upper edge of the absorption range, with long-time (>4h) frequency-locking accuracy being≤0.5MHz and long-time frequency stability being 10-9 . The experimental result indicated that the seed frequency and the pulse laser frequency have a deviation, which effect is called the laser chirp characteristics. Finally chirp test system was constructed and tested the frequency offset in time. And such frequency deviation is known as Chirp of the laser pulse. The real-time measured frequency difference of the continuous and pulsed lights was about 10MHz, long-time stability deviation was around 5MHz. After experimental testing technology mature, which can monitoring the signal at long-term with corrected the wind speed.

  9. Determination of the spatial resolution required for the HEDR dose code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Napier, B.A.; Simpson, J.C.

    1992-12-01

    A series of scoping calculations has been undertaken to evaluate the doses that may have been received by individuals living in the vicinity of the Hanford site. This scoping calculation (Calculation 007) examined the spatial distribution of potential doses resulting from releases in the year 1945. This study builds on the work initiated in the first scoping calculation, of iodine in cow's milk; the third scoping calculation, which added additional pathways; the fifth calculation, which addressed the uncertainty of the dose estimates at a point; and the sixth calculation, which extrapolated the doses throughout the atmospheric transport domain. A projectionmore » of dose to representative individuals throughout the proposed HEDR atmospheric transport domain was prepared on the basis of the HEDR source term. Addressed in this calculation were the contributions to iodine-131 thyroid dose of infants from (1) air submersion and groundshine external dose, (2) inhalation, (3) ingestion of soil by humans, (4) ingestion of leafy vegetables, (5) ingestion of other vegetables and fruits, (6) ingestion of meat, (7) ingestion of eggs, and (8) ingestion of cows' milk from-Feeding Regime 1 as described in scoping calculation 001.« less

  10. Calculation of Water Drop Trajectories to and About Arbitrary Three-Dimensional Bodies in Potential Airflow

    NASA Technical Reports Server (NTRS)

    Norment, H. G.

    1980-01-01

    Calculations can be performed for any atmospheric conditions and for all water drop sizes, from the smallest cloud droplet to large raindrops. Any subsonic, external, non-lifting flow can be accommodated; flow into, but not through, inlets also can be simulated. Experimental water drop drag relations are used in the water drop equations of motion and effects of gravity settling are included. Seven codes are described: (1) a code used to debug and plot body surface description data; (2) a code that processes the body surface data to yield the potential flow field; (3) a code that computes flow velocities at arrays of points in space; (4) a code that computes water drop trajectories from an array of points in space; (5) a code that computes water drop trajectories and fluxes to arbitrary target points; (6) a code that computes water drop trajectories tangent to the body; and (7) a code that produces stereo pair plots which include both the body and trajectories. Code descriptions include operating instructions, card inputs and printouts for example problems, and listing of the FORTRAN codes. Accuracy of the calculations is discussed, and trajectory calculation results are compared with prior calculations and with experimental data.

  11. Utilizing GPUs to Accelerate Turbomachinery CFD Codes

    NASA Technical Reports Server (NTRS)

    MacCalla, Weylin; Kulkarni, Sameer

    2016-01-01

    GPU computing has established itself as a way to accelerate parallel codes in the high performance computing world. This work focuses on speeding up APNASA, a legacy CFD code used at NASA Glenn Research Center, while also drawing conclusions about the nature of GPU computing and the requirements to make GPGPU worthwhile on legacy codes. Rewriting and restructuring of the source code was avoided to limit the introduction of new bugs. The code was profiled and investigated for parallelization potential, then OpenACC directives were used to indicate parallel parts of the code. The use of OpenACC directives was not able to reduce the runtime of APNASA on either the NVIDIA Tesla discrete graphics card, or the AMD accelerated processing unit. Additionally, it was found that in order to justify the use of GPGPU, the amount of parallel work being done within a kernel would have to greatly exceed the work being done by any one portion of the APNASA code. It was determined that in order for an application like APNASA to be accelerated on the GPU, it should not be modular in nature, and the parallel portions of the code must contain a large portion of the code's computation time.

  12. PASCO: Structural panel analysis and sizing code: Users manual - Revised

    NASA Technical Reports Server (NTRS)

    Anderson, M. S.; Stroud, W. J.; Durling, B. J.; Hennessy, K. W.

    1981-01-01

    A computer code denoted PASCO is described for analyzing and sizing uniaxially stiffened composite panels. Buckling and vibration analyses are carried out with a linked plate analysis computer code denoted VIPASA, which is included in PASCO. Sizing is based on nonlinear mathematical programming techniques and employs a computer code denoted CONMIN, also included in PASCO. Design requirements considered are initial buckling, material strength, stiffness and vibration frequency. A user's manual for PASCO is presented.

  13. Least squares parameter estimation methods for material decomposition with energy discriminating detectors

    PubMed Central

    Le, Huy Q.; Molloi, Sabee

    2011-01-01

    Purpose: Energy resolving detectors provide more than one spectral measurement in one image acquisition. The purpose of this study is to investigate, with simulation, the ability to decompose four materials using energy discriminating detectors and least squares minimization techniques. Methods: Three least squares parameter estimation decomposition techniques were investigated for four-material breast imaging tasks in the image domain. The first technique treats the voxel as if it consisted of fractions of all the materials. The second method assumes that a voxel primarily contains one material and divides the decomposition process into segmentation and quantification tasks. The third is similar to the second method but a calibration was used. The simulated computed tomography (CT) system consisted of an 80 kVp spectrum and a CdZnTe (CZT) detector that could resolve the x-ray spectrum into five energy bins. A postmortem breast specimen was imaged with flat panel CT to provide a model for the digital phantoms. Hydroxyapatite (HA) (50, 150, 250, 350, 450, and 550 mg∕ml) and iodine (4, 12, 20, 28, 36, and 44 mg∕ml) contrast elements were embedded into the glandular region of the phantoms. Calibration phantoms consisted of a 30∕70 glandular-to-adipose tissue ratio with embedded HA (100, 200, 300, 400, and 500 mg∕ml) and iodine (5, 15, 25, 35, and 45 mg∕ml). The x-ray transport process was simulated where the Beer–Lambert law, Poisson process, and CZT absorption efficiency were applied. Qualitative and quantitative evaluations of the decomposition techniques were performed and compared. The effect of breast size was also investigated. Results: The first technique decomposed iodine adequately but failed for other materials. The second method separated the materials but was unable to quantify the materials. With the addition of a calibration, the third technique provided good separation and quantification of hydroxyapatite, iodine, glandular, and adipose tissues. Quantification with this technique was accurate with errors of 9.83% and 6.61% for HA and iodine, respectively. Calibration at one point (one breast size) showed increased errors as the mismatch in breast diameters between calibration and measurement increased. A four-point calibration successfully decomposed breast diameter spanning the entire range from 8 to 20 cm. For a 14 cm breast, errors were reduced from 5.44% to 1.75% and from 6.17% to 3.27% with the multipoint calibration for HA and iodine, respectively. Conclusions: The results of the simulation study showed that a CT system based on CZT detectors in conjunction with least squares minimization technique can be used to decompose four materials. The calibrated least squares parameter estimation decomposition technique performed the best, separating and accurately quantifying the concentrations of hydroxyapatite and iodine. PMID:21361193

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le, Huy Q.; Molloi, Sabee

    Purpose: Energy resolving detectors provide more than one spectral measurement in one image acquisition. The purpose of this study is to investigate, with simulation, the ability to decompose four materials using energy discriminating detectors and least squares minimization techniques. Methods: Three least squares parameter estimation decomposition techniques were investigated for four-material breast imaging tasks in the image domain. The first technique treats the voxel as if it consisted of fractions of all the materials. The second method assumes that a voxel primarily contains one material and divides the decomposition process into segmentation and quantification tasks. The third is similar tomore » the second method but a calibration was used. The simulated computed tomography (CT) system consisted of an 80 kVp spectrum and a CdZnTe (CZT) detector that could resolve the x-ray spectrum into five energy bins. A postmortem breast specimen was imaged with flat panel CT to provide a model for the digital phantoms. Hydroxyapatite (HA) (50, 150, 250, 350, 450, and 550 mg/ml) and iodine (4, 12, 20, 28, 36, and 44 mg/ml) contrast elements were embedded into the glandular region of the phantoms. Calibration phantoms consisted of a 30/70 glandular-to-adipose tissue ratio with embedded HA (100, 200, 300, 400, and 500 mg/ml) and iodine (5, 15, 25, 35, and 45 mg/ml). The x-ray transport process was simulated where the Beer-Lambert law, Poisson process, and CZT absorption efficiency were applied. Qualitative and quantitative evaluations of the decomposition techniques were performed and compared. The effect of breast size was also investigated. Results: The first technique decomposed iodine adequately but failed for other materials. The second method separated the materials but was unable to quantify the materials. With the addition of a calibration, the third technique provided good separation and quantification of hydroxyapatite, iodine, glandular, and adipose tissues. Quantification with this technique was accurate with errors of 9.83% and 6.61% for HA and iodine, respectively. Calibration at one point (one breast size) showed increased errors as the mismatch in breast diameters between calibration and measurement increased. A four-point calibration successfully decomposed breast diameter spanning the entire range from 8 to 20 cm. For a 14 cm breast, errors were reduced from 5.44% to 1.75% and from 6.17% to 3.27% with the multipoint calibration for HA and iodine, respectively. Conclusions: The results of the simulation study showed that a CT system based on CZT detectors in conjunction with least squares minimization technique can be used to decompose four materials. The calibrated least squares parameter estimation decomposition technique performed the best, separating and accurately quantifying the concentrations of hydroxyapatite and iodine.« less

  15. Computation of Reacting Flows in Combustion Processes

    NASA Technical Reports Server (NTRS)

    Keith, Theo G., Jr.; Chen, Kuo-Huey

    1997-01-01

    The main objective of this research was to develop an efficient three-dimensional computer code for chemically reacting flows. The main computer code developed is ALLSPD-3D. The ALLSPD-3D computer program is developed for the calculation of three-dimensional, chemically reacting flows with sprays. The ALL-SPD code employs a coupled, strongly implicit solution procedure for turbulent spray combustion flows. A stochastic droplet model and an efficient method for treatment of the spray source terms in the gas-phase equations are used to calculate the evaporating liquid sprays. The chemistry treatment in the code is general enough that an arbitrary number of reaction and species can be defined by the users. Also, it is written in generalized curvilinear coordinates with both multi-block and flexible internal blockage capabilities to handle complex geometries. In addition, for general industrial combustion applications, the code provides both dilution and transpiration cooling capabilities. The ALLSPD algorithm, which employs the preconditioning and eigenvalue rescaling techniques, is capable of providing efficient solution for flows with a wide range of Mach numbers. Although written for three-dimensional flows in general, the code can be used for two-dimensional and axisymmetric flow computations as well. The code is written in such a way that it can be run in various computer platforms (supercomputers, workstations and parallel processors) and the GUI (Graphical User Interface) should provide a user-friendly tool in setting up and running the code.

  16. MARGINAL IODINE DEFICIENCY EXACERBATES PERCHLORATE THYROID TOXICITY.

    EPA Science Inventory

    The environmental contaminant perchlorate disrupts thyroid homeostasis via inhibition of iodine uptake into the thyroid. This work tested whether iodine deficiency exacerbates the effects of perchlorate. Female 27 day-old LE rats were fed a custom iodine deficient diet with 0, 50...

  17. Iodine Deficiency

    MedlinePlus

    ... public health problem globally. Approximately 40% of the world’s population remains at risk for iodine deficiency. Iodine Deficiency ... common preventable cause of intellectual disabilities in the world. Even mild iodine ... deficiency is seen in an entire population, it is best managed by ensuring that common ...

  18. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...-126 .1 .001 Iodine-129 .1 .01 Iodine-131 .1 .001 Iodine-132 10 .1 Iodine-133 1 .01 Iodine-134 10 .1...-125 1 .01 Arsenic-73 10 .1 Arsenic-74 1 .01 Arsenic-76 1 .01 Arsenic-77 10 .1 Barium-131 10 .1 Barium... Cerium-144 .1 .001 Cesium-131 100 1. Cesium-134m 100 1. Cesium-134 .1 .001 Cesium-135 1 .01 Cesium-136 10...

  19. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...-126 .1 .001 Iodine-129 .1 .01 Iodine-131 .1 .001 Iodine-132 10 .1 Iodine-133 1 .01 Iodine-134 10 .1...-125 1 .01 Arsenic-73 10 .1 Arsenic-74 1 .01 Arsenic-76 1 .01 Arsenic-77 10 .1 Barium-131 10 .1 Barium... Cerium-144 .1 .001 Cesium-131 100 1. Cesium-134m 100 1. Cesium-134 .1 .001 Cesium-135 1 .01 Cesium-136 10...

  20. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...-126 .1 .001 Iodine-129 .1 .01 Iodine-131 .1 .001 Iodine-132 10 .1 Iodine-133 1 .01 Iodine-134 10 .1...-125 1 .01 Arsenic-73 10 .1 Arsenic-74 1 .01 Arsenic-76 1 .01 Arsenic-77 10 .1 Barium-131 10 .1 Barium... Cerium-144 .1 .001 Cesium-131 100 1. Cesium-134m 100 1. Cesium-134 .1 .001 Cesium-135 1 .01 Cesium-136 10...

  1. Severe Hypothyroidism From Iodine Deficiency Associated With Parenteral Nutrition.

    PubMed

    Golekoh, Marjorie C; Cole, Conrad R; Jones, Nana-Hawa Yayah

    2016-11-01

    Parenteral nutrition is crucial for supply of nutrients in children who cannot tolerate a full enteral diet. In the United States, it is not standard of care to give iodine to children dependent on parenteral nutrition, hence iodine is not routinely included in the micronutrient package. Herein, we present a case of a boy with hypothyroidism secondary to iodine deficiency after prolonged exclusive use of parenteral nutrition. Our case highlights the importance of screening for iodine deficiency and administering timely iodine supplementation in these at-risk children to prevent iatrogenic hypothyroidism. © 2015 American Society for Parenteral and Enteral Nutrition.

  2. Iodine and Selenium Intakes of Postmenopausal Women in New Zealand.

    PubMed

    Brough, Louise; Gunn, Caroline A; Weber, Janet L; Coad, Jane; Jin, Ying; Thomson, Jasmine S; Mauze, Mathilde; Kruger, Marlena C

    2017-03-09

    Iodine and selenium are required for thyroid function. This study investigated iodine and selenium intakes in healthy, women aged 50-70 years ( n = 97) from three cities in the North Island of New Zealand, after mandatory fortification of bread with iodised salt. Iodine and selenium concentrations were determined in 24-h urine samples; daily intakes were extrapolated from amounts in urine (90% and 55% of daily intake, respectively). Three day diet diaries (3DDD) also estimated selenium and iodine (excluding iodised salt) intake. Median urinary iodine concentration (UIC) was 57 (41, 78) µg/L, indicating mild iodine deficiency. Estimated median iodine intake based on urine was 138 (100, 172) µg/day, below Recommended Dietary Intake (RDI) (150 µg/day) with 25% below Estimated Average Requirement (EAR) (100 µg/day). Estimated median selenium intake was 50 (36, 71) µg/day based on urine and 45 (36, 68) µg/day using 3DDD, below RDI (60 µg/day) with 49%-55% below EAR (50 µg/day). Median bread intakes were low at 1.8 (1.1, 2.7) serves/day; 25% consumed ≤1 serve/day. Although population iodine intakes improved following mandatory fortification, some had low intakes. Selenium intakes remain low. Further research should investigate thyroid function of low consumers of iodine fortified bread and/or selenium in New Zealand.

  3. Iodine in raw and pasteurized milk of dairy cows fed different amounts of potassium iodide.

    PubMed

    Norouzian, M A

    2011-02-01

    Relation between iodine (I) intake by lactating Holstein cows and iodine concentrations in raw and pasteurized milk were investigated. Four treatment groups with eight cows assigned to each treatment were fed a basal diet containing 0.534 mg I/kg alone or supplemented with potassium iodide at 2.5, 5 or 7.5 mg/kg in 7-week period. Iodine concentrations in raw milk increased with each increase in dietary I from 162.2 ng/ml for basal diet to 534.5, 559.8 and 607.5 ng/ml when 2.5, 5 and 7.5 mg/kg was fed as potassium iodide (P < 0.05). This trend was found for blood plasma and urine iodine concentration. Iodine supplementation had no significant effect on thyroidal hormones. high-temperature short-time (HTST) pasteurization process reduced I concentration. The mean iodine content found in the milk prior to heating processing was 466.0 ± 205.0 ng/ml, whereas for the processed milk this level was 349.5 ± 172.8 ng/ml. It was concluded that iodine supplementation above of NRC recommendation (0.5 mg/kg diet DM) resulted in significant increases in iodine concentrations in milk, although the effect of heating in HTST pasteurization process on iodine concentration was not negligible.

  4. A rechargeable iodine-carbon battery that exploits ion intercalation and iodine redox chemistry.

    PubMed

    Lu, Ke; Hu, Ziyu; Ma, Jizhen; Ma, Houyi; Dai, Liming; Zhang, Jintao

    2017-09-13

    Graphitic carbons have been used as conductive supports for developing rechargeable batteries. However, the classic ion intercalation in graphitic carbon has yet to be coupled with extrinsic redox reactions to develop rechargeable batteries. Herein, we demonstrate the preparation of a free-standing, flexible nitrogen and phosphorus co-doped hierarchically porous graphitic carbon for iodine loading by pyrolysis of polyaniline coated cellulose wiper. We find that heteroatoms could provide additional defect sites for encapsulating iodine while the porous carbon skeleton facilitates redox reactions of iodine and ion intercalation. The combination of ion intercalation with redox reactions of iodine allows for developing rechargeable iodine-carbon batteries free from the unsafe lithium/sodium metals, and hence eliminates the long-standing safety issue. The unique architecture of the hierarchically porous graphitic carbon with heteroatom doping not only provides suitable spaces for both iodine encapsulation and cation intercalation but also generates efficient electronic and ionic transport pathways, thus leading to enhanced performance.Carbon-based electrodes able to intercalate Li + and Na + ions have been exploited for high performing energy storage devices. Here, the authors combine the ion intercalation properties of porous graphitic carbons with the redox chemistry of iodine to produce iodine-carbon batteries with high reversible capacities.

  5. NASA Rotor 37 CFD Code Validation: Glenn-HT Code

    NASA Technical Reports Server (NTRS)

    Ameri, Ali A.

    2010-01-01

    In order to advance the goals of NASA aeronautics programs, it is necessary to continuously evaluate and improve the computational tools used for research and design at NASA. One such code is the Glenn-HT code which is used at NASA Glenn Research Center (GRC) for turbomachinery computations. Although the code has been thoroughly validated for turbine heat transfer computations, it has not been utilized for compressors. In this work, Glenn-HT was used to compute the flow in a transonic compressor and comparisons were made to experimental data. The results presented here are in good agreement with this data. Most of the measures of performance are well within the measurement uncertainties and the exit profiles of interest agree with the experimental measurements.

  6. Final report for the Tera Computer TTI CRADA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davidson, G.S.; Pavlakos, C.; Silva, C.

    1997-01-01

    Tera Computer and Sandia National Laboratories have completed a CRADA, which examined the Tera Multi-Threaded Architecture (MTA) for use with large codes of importance to industry and DOE. The MTA is an innovative architecture that uses parallelism to mask latency between memories and processors. The physical implementation is a parallel computer with high cross-section bandwidth and GaAs processors designed by Tera, which support many small computation threads and fast, lightweight context switches between them. When any thread blocks while waiting for memory accesses to complete, another thread immediately begins execution so that high CPU utilization is maintained. The Tera MTAmore » parallel computer has a single, global address space, which is appealing when porting existing applications to a parallel computer. This ease of porting is further enabled by compiler technology that helps break computations into parallel threads. DOE and Sandia National Laboratories were interested in working with Tera to further develop this computing concept. While Tera Computer would continue the hardware development and compiler research, Sandia National Laboratories would work with Tera to ensure that their compilers worked well with important Sandia codes, most particularly CTH, a shock physics code used for weapon safety computations. In addition to that important code, Sandia National Laboratories would complete research on a robotic path planning code, SANDROS, which is important in manufacturing applications, and would evaluate the MTA performance on this code. Finally, Sandia would work directly with Tera to develop 3D visualization codes, which would be appropriate for use with the MTA. Each of these tasks has been completed to the extent possible, given that Tera has just completed the MTA hardware. All of the CRADA work had to be done on simulators.« less

  7. Operations analysis (study 2.1). Program listing for the LOVES computer code

    NASA Technical Reports Server (NTRS)

    Wray, S. T., Jr.

    1974-01-01

    A listing of the LOVES computer program is presented. The program is coded partially in SIMSCRIPT and FORTRAN. This version of LOVES is compatible with both the CDC 7600 and the UNIVAC 1108 computers. The code has been compiled, loaded, and executed successfully on the EXEC 8 system for the UNIVAC 1108.

  8. Analysis of the Length of Braille Texts in English Braille American Edition, the Nemeth Code, and Computer Braille Code versus the Unified English Braille Code

    ERIC Educational Resources Information Center

    Knowlton, Marie; Wetzel, Robin

    2006-01-01

    This study compared the length of text in English Braille American Edition, the Nemeth code, and the computer braille code with the Unified English Braille Code (UEBC)--also known as Unified English Braille (UEB). The findings indicate that differences in the length of text are dependent on the type of material that is transcribed and the grade…

  9. A MATLAB based 3D modeling and inversion code for MT data

    NASA Astrophysics Data System (ADS)

    Singh, Arun; Dehiya, Rahul; Gupta, Pravin K.; Israil, M.

    2017-07-01

    The development of a MATLAB based computer code, AP3DMT, for modeling and inversion of 3D Magnetotelluric (MT) data is presented. The code comprises two independent components: grid generator code and modeling/inversion code. The grid generator code performs model discretization and acts as an interface by generating various I/O files. The inversion code performs core computations in modular form - forward modeling, data functionals, sensitivity computations and regularization. These modules can be readily extended to other similar inverse problems like Controlled-Source EM (CSEM). The modular structure of the code provides a framework useful for implementation of new applications and inversion algorithms. The use of MATLAB and its libraries makes it more compact and user friendly. The code has been validated on several published models. To demonstrate its versatility and capabilities the results of inversion for two complex models are presented.

  10. Evaluation of iodine nutritional status in Tehran, Iran: iodine deficiency within iodine sufficiency.

    PubMed

    Nazeri, Pantea; Mirmiran, Parvin; Mehrabi, Yadollah; Hedayati, Mehdi; Delshad, Hossein; Azizi, Fereidoun

    2010-12-01

    Production of iodized salt in Iran for household consumption began in 1990. Previous studies have reported sustainable elimination of iodine deficiency disorders in Iran. The aim of this study was to evaluate the iodine nutritional status in Tehran in 2009. In this cross-sectional study, 383 Tehranian households were enrolled through randomized cluster sampling and a total of 639 adult subjects (242 men and 397 women), aged 19 and over, participated. A 24-hour urine sample was collected for measurement of urinary iodine, sodium, and creatinine concentrations using the digestion method, flame photometry, and autoanalyzer assay, respectively. Salt intake was estimated and iodine content of household salt was measured by titration. Median (interquartile range) iodine content of household salt and urinary iodine concentration (UIC) in Tehran were 21.2 (3.2-31.7) parts per million and 70.0 (34.0-131.2) μg/L, respectively. There was no statistically significant difference in 24-hour UICs between men and women. Median (interquartile range) daily salt intake was 7.6 (5.5-9.8) g, which was not different in the two genders. According to the WHO/ICCIDD/UNICEF classification, 11.2%, 25.9%, 26.7%, 25.1%, 8.0%, and 3.2% of participants had UIC <20, 20-49, 50-99, 100-199, 200-299, and >300 μg/L, respectively. Mild iodine deficiency has recurred in Tehranians. The results emphasize the need for continuous monitoring in all regions, even in a country with iodine sufficiency.

  11. The importance of iodine in public health.

    PubMed

    Lazarus, John H

    2015-08-01

    Iodine (I) deficiency has been known for more than a century and is known to cause cretinism at the extreme end of the spectrum but also, importantly, impaired development and neurocognition in areas of mild deficiency. The WHO has indicated that median urinary iodine of 100-199 μg/l in a population is regarded as indicative of an adequate iodine intake. The understanding of the spectrum of iodine deficiency disorders led to the formation of The International Council for the Control of Iodine Deficiency Disorders which has promulgated the use of household iodized salt and the use of such salt in food processing and manufacture. Iodine deficiency is particularly important in pregnancy as the fetus relies on maternal thyroxine (T4) exclusively during the first 14 weeks and also throughout gestation. As this hormone is critical to brain and nervous system maturation, low maternal T4 results in low child intelligence quotient. The recommendation for I intake in pregnancy is 250 μg/day to prevent fetal and child brain function impairment. During the past 25 years, the number of countries with I deficiency has reduced to 32; these still include many European developed countries. Sustainability of adequate iodine status must be achieved by continuous monitoring and where this has not been performed I deficiency has often recurred. More randomized controlled trials of iodine supplementation in pregnancy are required in mild iodine-deficient areas to inform public health strategy and subsequent government action on suitable provision of iodine to the population at risk.

  12. Knowledge and practices regarding iodine supplementation: A national survey of healthcare providers.

    PubMed

    Guess, Kimberly; Malek, Lenka; Anderson, Amanda; Makrides, Maria; Zhou, Shao J

    2017-02-01

    Little is known of healthcare providers' awareness and implementation of the National Health and Medical Research Council's recommendation regarding iodine supplementation during pre-conception, pregnancy and lactation. To assess knowledge and practices of Australian healthcare providers in relation to the National Health and Medical Research Council's iodine supplement recommendation. Obstetricians, gynaecologists, general practitioners, dietitians and midwives were recruited through their relevant professional bodies to participate in an online survey. The survey was completed by 396 healthcare providers Australia-wide. While 71% of healthcare providers' were aware of the National Health and Medical Research Council's recommendation for iodine supplementation, fewer were aware of the recommended dose (38%) or duration (44%). Seventy-three percent of healthcare providers recommended iodine supplements in pregnancy, 56% when planning pregnancy and 52% during lactation. The main reasons for not recommending iodine supplements included belief there was no need for iodine supplements due to mandatory iodine fortification of food (28%) and unawareness of the recommendation (25%). Awareness of the recommendation was positively associated with recommending iodine supplements while length of practice, time spent per consultation, age or area of practice were not associated with recommending iodine supplements. There is a need to improve healthcare providers' knowledge of and adherence to the National Health and Medical Research Council's iodine supplement recommendation. Strategies within antenatal and postnatal services, as well as public health initiatives, are required to improve the knowledge and practices of healthcare providers. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  13. Maternal Iodine Intake and Offspring Attention-Deficit/Hyperactivity Disorder: Results from a Large Prospective Cohort Study

    PubMed Central

    Abel, Marianne Hope; Aase, Heidi; Reichborn-Kjennerud, Ted

    2017-01-01

    Current knowledge about the relationship between mild to moderately inadequate maternal iodine intake and/or supplemental iodine on child neurodevelopment is sparse. Using information from 77,164 mother-child pairs in the Norwegian Mother and Child Cohort Study, this study explored associations between maternal iodine intake and child attention-deficit/hyperactivity disorder (ADHD) diagnosis, registered in the Norwegian Patient Registry and maternally-reported child ADHD symptoms at eight years of age. Pregnant women reported food and supplement intakes by questionnaire in gestational week 22. In total, 1725 children (2.2%) were diagnosed with ADHD. In non-users of supplemental iodine (53,360 mothers), we found no association between iodine intake from food and risk of child ADHD diagnosis (p = 0.89), while low iodine from food (<200 µg/day) was associated with higher child ADHD symptom scores (adjusted difference in score up to 0.08 standard deviation (SD), p < 0.001, n = 19,086). In the total sample, we found no evidence of beneficial effects of maternal use of iodine-containing supplements (n = 23,804) on child ADHD diagnosis or symptom score. Initiation of iodine supplement use in gestational weeks 0–12 was associated with an increased risk of child ADHD (both measures). In conclusion, insufficient maternal iodine intake was associated with increased child ADHD symptom scores at eight years of age, but not with ADHD diagnosis. No reduction of risk was associated with maternal iodine supplement use. PMID:29137191

  14. 21 CFR 1310.09 - Temporary exemption from registration.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacture, distribute, import, or export regulated iodine, including regulated iodine chemical mixtures... a chemical mixture containing iodine on or before August 31, 2007. The exemption will remain in... distributes, imports, or exports a chemical mixture containing iodine whose application for exemption is...

  15. Multi-energy spectral CT: adding value in emergency body imaging.

    PubMed

    Punjabi, Gopal V

    2018-04-01

    Most vendors offer scanners capable of dual- or multi-energy computed tomography (CT) imaging. Advantages of multi-energy CT scanning include superior tissue characterization, detection of subtle iodine uptake differences, and opportunities to reduce contrast dose. However, utilization of this technology in the emergency department (ED) remains low. The purpose of this pictorial essay is to illustrate the value of multi-energy CT scanning in emergency body imaging.

  16. Applications of automatic differentiation in computational fluid dynamics

    NASA Technical Reports Server (NTRS)

    Green, Lawrence L.; Carle, A.; Bischof, C.; Haigler, Kara J.; Newman, Perry A.

    1994-01-01

    Automatic differentiation (AD) is a powerful computational method that provides for computing exact sensitivity derivatives (SD) from existing computer programs for multidisciplinary design optimization (MDO) or in sensitivity analysis. A pre-compiler AD tool for FORTRAN programs called ADIFOR has been developed. The ADIFOR tool has been easily and quickly applied by NASA Langley researchers to assess the feasibility and computational impact of AD in MDO with several different FORTRAN programs. These include a state-of-the-art three dimensional multigrid Navier-Stokes flow solver for wings or aircraft configurations in transonic turbulent flow. With ADIFOR the user specifies sets of independent and dependent variables with an existing computer code. ADIFOR then traces the dependency path throughout the code, applies the chain rule to formulate derivative expressions, and generates new code to compute the required SD matrix. The resulting codes have been verified to compute exact non-geometric and geometric SD for a variety of cases. in less time than is required to compute the SD matrix using centered divided differences.

  17. The role of positron emission tomography and positron emission tomography/computed tomography in thyroid tumours: an overview.

    PubMed

    Treglia, Giorgio; Muoio, Barbara; Giovanella, Luca; Salvatori, Massimo

    2013-05-01

    Positron emission tomography (PET) and PET/computed tomography (PET/CT) with different tracers have been increasingly used in patients with thyroid tumours. The aim of this article is to perform an overview based on literature data about the usefulness of PET imaging in this setting. The role of Fluorine-18-Fluorodeoxyglucose (FDG) PET and PET/CT in differentiated thyroid carcinoma (DTC) is well established, particularly in patients presenting with elevated serum thyroglobulin levels and negative radioiodine whole-body scan. Iodine-124 PET and PET/CT may serve a role in staging DTC and obtaining lesional dosimetry for a better and more rationale planning of treatment with Iodine-131. FDG-PET and PET/CT are useful in the post-thyroidectomy staging of high-risk patients with less differentiated histological subtypes. PET and PET/CT with different tracers seem to be useful methods in localizing the source of elevated calcitonin levels in patients with recurrent medullary thyroid carcinoma. Incorporation of FDG-PET or PET/CT into the initial workup of patients with indeterminate thyroid nodules at fine needle aspiration biopsy deserves further investigation. FDG-PET report should suggest further evaluation when focal thyroid incidentalomas are described because these findings are associated with a significant risk of cancer.

  18. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    PubMed Central

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  19. X-ray computed tomography imaging of a tumor with high sensitivity using gold nanoparticles conjugated to a cancer-specific antibody via polyethylene glycol chains on their surface

    NASA Astrophysics Data System (ADS)

    Nakagawa, Tomohiko; Gonda, Kohsuke; Kamei, Takashi; Cong, Liman; Hamada, Yoh; Kitamura, Narufumi; Tada, Hiroshi; Ishida, Takanori; Aimiya, Takuji; Furusawa, Naoko; Nakano, Yasushi; Ohuchi, Noriaki

    2016-01-01

    Contrast agents are often used to enhance the contrast of X-ray computed tomography (CT) imaging of tumors to improve diagnostic accuracy. However, because the iodine-based contrast agents currently used in hospitals are of low molecular weight, the agent is rapidly excreted from the kidney or moves to extravascular tissues through the capillary vessels, depending on its concentration gradient. This leads to nonspecific enhancement of contrast images for tissues. Here, we created gold (Au) nanoparticles as a new contrast agent to specifically image tumors with CT using an enhanced permeability and retention (EPR) effect. Au has a higher X-ray absorption coefficient than does iodine. Au nanoparticles were supported with polyethylene glycol (PEG) chains on their surface to increase the blood retention and were conjugated with a cancer-specific antibody via terminal PEG chains. The developed Au nanoparticles were injected into tumor-bearing mice, and the distribution of Au was examined with CT imaging, transmission electron microscopy, and elemental analysis using inductively coupled plasma optical emission spectrometry. The results show that specific localization of the developed Au nanoparticles in the tumor is affected by a slight difference in particle size and enhanced by the conjugation of a specific antibody against the tumor.

  20. Fundamentals, current state of the development of, and prospects for further improvement of the new-generation thermal-hydraulic computational HYDRA-IBRAE/LM code for simulation of fast reactor systems

    NASA Astrophysics Data System (ADS)

    Alipchenkov, V. M.; Anfimov, A. M.; Afremov, D. A.; Gorbunov, V. S.; Zeigarnik, Yu. A.; Kudryavtsev, A. V.; Osipov, S. L.; Mosunova, N. A.; Strizhov, V. F.; Usov, E. V.

    2016-02-01

    The conceptual fundamentals of the development of the new-generation system thermal-hydraulic computational HYDRA-IBRAE/LM code are presented. The code is intended to simulate the thermalhydraulic processes that take place in the loops and the heat-exchange equipment of liquid-metal cooled fast reactor systems under normal operation and anticipated operational occurrences and during accidents. The paper provides a brief overview of Russian and foreign system thermal-hydraulic codes for modeling liquid-metal coolants and gives grounds for the necessity of development of a new-generation HYDRA-IBRAE/LM code. Considering the specific engineering features of the nuclear power plants (NPPs) equipped with the BN-1200 and the BREST-OD-300 reactors, the processes and the phenomena are singled out that require a detailed analysis and development of the models to be correctly described by the system thermal-hydraulic code in question. Information on the functionality of the computational code is provided, viz., the thermalhydraulic two-phase model, the properties of the sodium and the lead coolants, the closing equations for simulation of the heat-mass exchange processes, the models to describe the processes that take place during the steam-generator tube rupture, etc. The article gives a brief overview of the usability of the computational code, including a description of the support documentation and the supply package, as well as possibilities of taking advantages of the modern computer technologies, such as parallel computations. The paper shows the current state of verification and validation of the computational code; it also presents information on the principles of constructing of and populating the verification matrices for the BREST-OD-300 and the BN-1200 reactor systems. The prospects are outlined for further development of the HYDRA-IBRAE/LM code, introduction of new models into it, and enhancement of its usability. It is shown that the program of development and practical application of the code will allow carrying out in the nearest future the computations to analyze the safety of potential NPP projects at a qualitatively higher level.

  1. Performance assessment of KORAT-3D on the ANL IBM-SP computer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexeyev, A.V.; Zvenigorodskaya, O.A.; Shagaliev, R.M.

    1999-09-01

    The TENAR code is currently being developed at the Russian Federal Nuclear Center (VNIIEF) as a coupled dynamics code for the simulation of transients in VVER and RBMK systems and other nuclear systems. The neutronic module in this code system is KORAT-3D. This module is also one of the most computationally intensive components of the code system. A parallel version of KORAT-3D has been implemented to achieve the goal of obtaining transient solutions in reasonable computational time, particularly for RBMK calculations that involve the application of >100,000 nodes. An evaluation of the KORAT-3D code performance was recently undertaken on themore » Argonne National Laboratory (ANL) IBM ScalablePower (SP) parallel computer located in the Mathematics and Computer Science Division of ANL. At the time of the study, the ANL IBM-SP computer had 80 processors. This study was conducted under the auspices of a technical staff exchange program sponsored by the International Nuclear Safety Center (INSC).« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jans, H-S; Dept. of Oncology, University of Alberta, Edmonton, AB; Stypinski, D

    Purpose: To compare the radiation dose to normal organs from the radio-iodinated, hypoxia-binding radiosensitizer iodoazomycin arabinoside (IAZA) for three different isotopes of iodine. Methods: Dosimety studies with normal volunteers had been carried out with [{sup 123}I]IAZA, a drug binding selectively to hypoxic sites. Two other isotopes of iodine, {sup 131}I and {sup 124}I, offer the opportunity to use IAZA as an agent for radioisotope therapy and as an imaging tracer for Positron Emission Tomography. Radioisotope dosimetry for {sup 131}I and {sup 124}I was performed by first deriving from the [{sup 123}I]IAZA studies biological uptake and excretion data. The cumulated activitiesmore » for {sup 131}I or {sup 124}I where obtained by including their half-lives when integrating the biological data and then extrapolating to infinite time points considering a) physical decay only or b) physical and biological excretion. Doses were calculated using the Medical Internal Radiation Dose (MIRD) schema (OLINDA1.1 code, Vanderbilt 2007). Results: Compared to {sup 123}I, organ doses were elevated on average by a factor 6 and 9 for {sup 131}I and {sup 124}I, respectively, if both physical decay and biological excretion were modeled. If only physical decay is considered, doses increase by a factor 18 ({sup 131}I) and 19 ({sup 124}I). Highest organ doses were observed in intestinal walls, urinary bladder and thyroid. Effective doses increased by a factor 11 and 14 for {sup 131}I and {sup 124}I, respectively, if biological and physical decay are present. Purely physical decay yields a 23-fold increase over {sup 123}I for both, {sup 131}I and {sup 124}I. Conclusion: Owing to the significant dose increase, caused by their longer half life and the approximately 10 times larger electronic dose deposited in tissue per nuclear decay, normal tissue doses of IAZA labeled with {sup 131}I and {sup 124}I need to be carefully considered when designing imaging and therapy protocols for clinical trials. Effective blocking of iodine uptake in the thyroid is essential. Alberta Innovates - Health Solutions (AIHS) and Canadian Institutes of Health Research (CIHR)« less

  3. Assessment of iodine status and associated factors in vulnerable populations in Henan Province, China, in 2012.

    PubMed

    Yang, Jin; Zheng, Heming; Li, Xiaofeng; Zhu, Lin; Hao, Zongyu; Chen, Gan; Liu, Yang; Wang, Yanli

    2014-01-01

    Iodine content in table salt was adjusted from 30-50 mg/kg to 21-39 mg/kg from March of 2012 in Henan Province, China. The vulnerable population may be at risk of iodine deficiency. To determine whether the iodine intake was sufficient in vulnerable populations and to investigate what factors may be associated with iodine status in these vulnerable populations in Henan Province, China. A cross-sectional survey was conducted in 17 cities in Henan Province, China, from April 2012 to December 2012 to assess the iodine status in vulnerable populations, including women of reproductive-age (n=2648), pregnant women (n=39684), lactating women (n=6859), infants <2 years of age (n=16481), and children aged 8-10 years (n=3198). Questionnaires (n=4865) related to demographic and dietary factors were collected from the investigated women to identify factors that were related to iodine intake and iodine status. The median urinary iodine concentrations (mUICs) were 205 μg/L, 198 μg/L, 167 μg/L, 205 μg/L and 200 μg/L, respectively, in reproductiveage, pregnant and lactating women, infants <2 years of age and children aged 8-10 years. Higher income, and consuming more poultry and fish in the diet had positive impact on UIC levels. Low salt intake, consuming more rice and vegetables in the diet were negative factors for UIC. Iodine status of the vulnerable populations was generally adequate in Henan Province, China, according to WHO criteria. But the mUICs were slightly above the adequate level in reproductive-age women and children aged 8-10 years. It's important to monitor the iodine status in vulnerable populations after the adjustment on iodine content in table salt.

  4. Research needs for assessing iodine intake, iodine status, and the effects of maternal iodine supplementation12

    PubMed Central

    Ershow, Abby G; Coates, Paul M; Swanson, Christine A

    2016-01-01

    The Office of Dietary Supplements of the NIH convened 3 workshops on iodine nutrition in Rockville, Maryland, in 2014. The purpose of the current article is to summarize and briefly discuss a list of research and resource needs developed with the input of workshop participants. This list is composed of the basic, clinical, translational, and population studies required for characterizing the benefits and risks of iodine supplementation, along with related data, analyses, evaluations, methods development, and supporting activities. Ancillary studies designed to use the participant, biological sample, and data resources of ongoing and completed studies (including those not originally concerned with iodine) may provide an efficient, cost-effective means to address some of these research and resource needs. In the United States, the foremost question is whether neurobehavioral development in the offspring of mildly to moderately iodine-deficient women is improved by maternal iodine supplementation during pregnancy. It is important to identify the benefits and risks of iodine supplementation in all population subgroups so that supplementation can be targeted, if necessary, to avoid increasing the risk of thyroid dysfunction and related adverse health effects in those with high iodine intakes. Ultimately, there will be a need for well-designed trials and other studies to assess the impact of maternal supplementation on neurodevelopmental outcomes in the offspring. However, 2 basic information gaps loom ahead of such a study: the development of robust, valid, and convenient biomarkers of individual iodine status and the identification of infant and toddler neurobehavioral development endpoints that are sensitive to mild maternal iodine deficiency during pregnancy and its reversal by supplementation. PMID:27534640

  5. Can an Educational Intervention Improve Iodine Nutrition Status in Pregnant Women? A Randomized Controlled Trial.

    PubMed

    Amiri, Parisa; Hamzavi Zarghani, Najmeh; Nazeri, Pantea; Ghofranipour, Fazlollah; Karimi, Mehrdad; Amouzegar, Atieh; Mirmiran, Parvin; Azizi, Fereidoun

    2017-03-01

    Because of their increased need for iodine, pregnant women are among the high-risk groups for iodine deficiency. The purpose of this study was to evaluate the effectiveness of an educational program on the iodine nutrition status of pregnant women. In this randomized controlled trial, 100 pregnant women were randomly selected from five healthcare centers in the southern region of Tehran, the capital of Iran. In the intervention group, pregnant women received a four-month educational program, which included two face-to-face educational sessions, using a researcher-designed educational pamphlet in the second and third trimesters, and two follow-up telephone calls. Knowledge, attitude, and practice (KAP) scores, urinary iodine concentration (UIC), and salt iodine content were assessed at baseline and four months after the intervention. At baseline, there were significant associations between knowledge and attitude (r = 0.38, p = 0.03) between practice and UIC (r = 0.28, p = 0.01) and between UIC and iodine content of salt (r = 0.24, p = 0.009). Although a significant difference was found in mean KAP scores between the two groups after the educational intervention, scores were significantly higher in the intervention group compared with controls (p < 0.01). There were no significant differences in UIC and iodine content of salt between the two groups at follow-up. Despite educational intervention increasing KAP among women regarding the importance of iodine and iodized salt consumption during pregnancy, their iodine status did not improve. Considering the main socio-environmental determinants of iodine deficiency, in particular, the monitoring of salt fortification, prescribing iodine containing supplements as well as improving health literacy in pregnant women seem essential strategies.

  6. Controlled iodine release from polyurethane sponges for water decontamination.

    PubMed

    Aviv, Oren; Laout, Natalia; Ratner, Stanislav; Harik, Oshrat; Kunduru, Konda Reddy; Domb, Abraham J

    2013-12-28

    Iodinated polyurethane (IPU) sponges were prepared by immersing sponges in aqueous/organic solutions of iodine or exposing sponges to iodine vapors. Iodine was readily adsorbed into the polymers up to 100% (w/w). The adsorption of iodine on the surface was characterized by XPS and SEM analyses. The iodine loaded IPU sponges were coated with ethylene vinyl acetate (EVA), in order to release iodine in a controlled rate for water decontamination combined with active carbon cartridge, which adsorbs the iodine residues after the microbial inactivation. The EVA coated IPU were incorporated in a water purifier and tested for iodine release to water and for microbial inactivation efficiency according to WQA certification program against P231/EPA for 250l, using 25l a day with flow rate of 6-8min/1l. The antimicrobial activity was also studied against Escherichia coli and MS2 phage. Bacterial results exceeded the minimal requirement for bacterial removal of 6log reduction throughout the entire lifespan. At any testing point, no bacteria was detected in the outlet achieving more than 7.1 to more than 8log reduction as calculated upon the inlet concentration. Virus surrogate, MS2, reduction results varied from 4.11log reduction under tap water, and 5.11log reduction under basic water (pH9) to 1.32 for acidic water (pH5). Controlled and stable iodine release was observed with the EVA coated IPU sponges and was effective in deactivating the bacteria and virus present in the contaminated water and thus, these iodinated PU systems could be used in water purification to provide safe drinking water. These sponges may find applications as disinfectants in medicine. © 2013.

  7. Prevalence of goitre and urinary iodine status of primary-school children in Lesotho.

    PubMed Central

    Sebotsa, Masekonyela Linono Damane; Dannhauser, Andre; Jooste, Pieter L.; Joubert, Gina

    2003-01-01

    OBJECTIVE: To estimate the prevalence of goitre, urinary iodine status, coverage of supplementation of iodized oil capsules, and current use of iodized salt in children in Lesotho. METHODS: Cross-sectional study of children from 50 primary schools in Lesotho. Thyroid glands of children aged 8-12 years were measured by palpation and graded according to the WHO, UNICEF, and the International Council for the Control of Iodine Deficiency's (ICCIDD) joint criteria. The use of iodized oil capsules was determined by a structured questionnaire and verified with the children's health booklets. Iodine content of household salt samples was analysed. Casual urine samples were analysed for urinary iodine. FINDINGS: Median urinary iodine concentrations of 26.3 microg/l (range 22.3-47.9 microg/l) indicated moderate iodine deficiency. More children in the mountains than in the lowlands were severely iodine deficient (17.7% vs 1.9%). Adjusted prevalence of goitre (4.9%) increased with age, was higher in girls than boys, and ranged from 2.2% to 8.8% in the different districts; this indicated no public health problem. Overall, 94.4% of salt samples were iodized, and coverage of supplementation with iodized oil capsules was 55.1%. CONCLUSION: Mild-to-moderate iodine deficiency exists in Lesotho. Iodine deficiency was more severe in the mountains than the lowlands and is still a concern for public health. Use of iodized salt coupled with iodized oil supplementation effectively controls iodine deficiency disorders. Effective monitoring programmes would ensure the use of adequately iodized salt throughout Lesotho and serve to evaluate progress towards optimal iodine nutrition. Iodized oil capsule supplementation should continue in the mountains. PMID:12640473

  8. Exploration of the safe upper level of iodine intake in euthyroid Chinese adults: a randomized double-blind trial.

    PubMed

    Sang, Zhongna; Wang, Peizhong Peter; Yao, Zhaixiao; Shen, Jun; Halfyard, Beth; Tan, Long; Zhao, Na; Wu, Yuntang; Gao, Shuo; Tan, Jian; Liu, Jiayu; Chen, Zupei; Zhang, Wanqi

    2012-02-01

    The beneficial health effects associated with Universal Salt Iodization are well known. Yet, little is known about the possible adverse health effects in people with high iodine intake and the safe daily intake upper limit in the Chinese population. The objective of this study was to explore the safe upper level of total daily iodine intake among adults in China. A 4-wk, double-blind, placebo-controlled, randomized controlled trial was conducted in 256 euthyroid adults. Participants were randomly assigned to 12 intervention groups with various iodine supplement doses ranging from 0 to 2000 μg/d. Total iodine intake included iodine from both supplements and diet. Multiple outcome measures were used to evaluate possible adverse effects, including thyroid function, thyroid size, and urinary iodine. The mean iodine intake from the diets and salt intake of the participants were 105 ± 25 and 258 ± 101 μg/d, respectively. In comparison with the placebo group, all iodide-supplemented groups responded with significant increases in median urinary iodine concentrations (P < 0.05) and in thyroid-stimulating hormone concentration (P < 0.05). Thyroid volume decreased after 4 wk in the high-iodine intervention groups (1500-2000 μg). Subclinical hypothyroidism appeared in the groups that received 400 μg I (5%) and 500-2000 μg I (15-47%). This study showed that subclinical hypothyroidism appeared in the participants who took the 400-μg I supplement, which provided a total iodine intake of ∼800 μg/d. Thus, we caution against a total daily iodine intake that exceeds 800 μg/d in China and recommend further research to determine a safe daily upper limit.

  9. More hypothyroidism and less hyperthyroidism with sufficient iodine nutrition compared to mild iodine deficiency--a comparative population-based study of older people.

    PubMed

    Andersen, Stig; Iversen, Finn; Terpling, Steen; Pedersen, Klaus Michael; Gustenhoff, Peter; Laurberg, Peter

    2009-10-20

    To assess the occurrence of thyroid disorders and autoimmunity in a geriatric population with long-standing recommended iodine intake of natural origin compared to mild iodine deficiency. Cross-sectional, comparative, population-based study in two areas with different iodine intakes due to different tap water iodine contents. Residents of Randers (n=212) or Skagen (n=218), Denmark, aged 75-80 years. Blood samples were collected for measuring thyrotropin (TSH), triiodothyronine, thyroxine, thyroid peroxidase antibody (TPOAb), thyroglobulin antibody (TGAb), thyroglobulin (TG); iodine excretion estimated from iodine and creatinine measured in spot urine samples; questionnaire on history of thyroid disease, medication and vitamin use; clinical examination of the neck. Median urinary iodine excretion was 50 microg/24h in Randers and 177 microg/24h in Skagen (p<0.001). A history of thyroid disease was reported by 40 (9.3%) dominated by goitre (n=22) in Randers and hypothyroidism and Graves Disease (n=15) in Skagen (p<0.001). We found visible goitre in 26% of Randers dwellers and none in Skagen (p<0.001). Hyperthyroidism with TSH below the reference range was present in 26% of Randers and 6% of Skagen dwellers while 6% and 13%, respectively, were hypothyroid with TSH above the reference range (p<0.001). More Randers than Skagen participants harboured a thyroid antibody (42% vs. 32%, p=0.006). Recommended iodine intake associated with more hypothyroidism, less hyperthyroidism and goiters, low TGAb prevalence and lower TG level in serum than did iodine deficiency. TPOAb was similar in the iodine replete and deficient geriatric populations.

  10. Low-level seaweed supplementation improves iodine status in iodine-insufficient women.

    PubMed

    Combet, Emilie; Ma, Zheng Feei; Cousins, Frances; Thompson, Brett; Lean, Michael E J

    2014-09-14

    Iodine insufficiency is now a prominent issue in the UK and other European countries due to low intakes of dairy products and seafood (especially where iodine fortification is not in place). In the present study, we tested a commercially available encapsulated edible seaweed (Napiers Hebridean Seagreens® Ascophyllum nodosum species) for its acceptability to consumers and iodine bioavailability and investigated the impact of a 2-week daily seaweed supplementation on iodine concentrations and thyroid function. Healthy non-pregnant women of childbearing age, self-reporting low dairy product and seafood consumption, with no history of thyroid or gastrointestinal disease were recruited. Seaweed iodine (712 μg, in 1 g seaweed) was modestly bioavailable at 33 (interquartile range (IQR) 28-46) % of the ingested iodine dose compared with 59 (IQR 46-74) % of iodine from the KI supplement (n 22). After supplement ingestion (2 weeks, 0·5 g seaweed daily, n 42), urinary iodine excretion increased from 78 (IQR 39-114) to 140 (IQR 103-195) μg/l (P< 0·001). The concentrations of thyroid-stimulating hormone increased from 1·5 (IQR 1·2-2·2) to 2·1 (IQR 1·3-2·9) mIU/l (P< 0·001), with two participants having concentrations exceeding the normal range after supplement ingestion (but normal free thyroxine concentrations). There was no change in the concentrations of other thyroid hormones after supplement ingestion. The seaweed was palatable and acceptable to consumers as a whole food or as a food ingredient and effective as a source of iodine in an iodine-insufficient population. In conclusion, seaweed inclusion in staple foods would serve as an alternative to fortification of salt or other foods with KI.

  11. Profugus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Thomas; Hamilton, Steven; Slattery, Stuart

    Profugus is an open-source mini-application (mini-app) for radiation transport and reactor applications. It contains the fundamental computational kernels used in the Exnihilo code suite from Oak Ridge National Laboratory. However, Exnihilo is production code with a substantial user base. Furthermore, Exnihilo is export controlled. This makes collaboration with computer scientists and computer engineers difficult. Profugus is designed to bridge that gap. By encapsulating the core numerical algorithms in an abbreviated code base that is open-source, computer scientists can analyze the algorithms and easily make code-architectural changes to test performance without compromising the production code values of Exnihilo. Profugus is notmore » meant to be production software with respect to problem analysis. The computational kernels in Profugus are designed to analyze performance, not correctness. Nonetheless, users of Profugus can setup and run problems with enough real-world features to be useful as proof-of-concept for actual production work.« less

  12. Mineral resource of the month: iodine

    USGS Publications Warehouse

    Polyak, Désirée E.

    2009-01-01

    The article focuses on iodine, its benefits and adverse effects, and its production and consumption. It states that iodine is essential to humans for it produces thyroid hormones to nourish thyroid glands but excessive intake could cause goiter, hyperthyroidism or hypothyroidism. U.S. laws require salt iodization to help prevent diseases. Chile and Japan are the world's leading iodine producer while in the U.S. iodine is mined from deep well brines in northern Oklahoma.

  13. Misclassification of iodine intake level from morning spot urine samples with high iodine excretion among Inuit and non-Inuit in Greenland.

    PubMed

    Andersen, Stig; Waagepetersen, Rasmus; Laurberg, Peter

    2015-05-14

    Iodine nutrition is commonly assessed from iodine excretion in urine. A 24 h urine sample is ideal, but it is cumbersome and inconvenient. Hence, spot urine samples with creatinine to adjust for differences in void volume are widely used. Still, the importance of ethnicity and the timing of spot urine samples need to be settled. We, thus, collected 104 early morning spot urine samples and 24 h urine samples from Inuit and non-Inuit living in Greenland. Diet was assessed by a FFQ. Demographic data were collected from the national registry and by questionnaires. Iodine was measured using the Sandell-Kolthoff reaction, creatinine using the Jaffe method and para-amino benzoic acid by the HPLC method for the estimation of completeness of urine sampling and compensation of incomplete urine samples to 24 h excretion. A population-based recruitment was done from the capital city, a major town and a settlement (n 36/48/20). Participants were seventy-eight Inuit and twenty-six non-Inuit. The median 24 h iodine excretion was 138 (25th-75th percentile 89-225) μg/97 (25th-75th percentile 72-124) μg in Inuit/non-Inuit (P= 0.030), and 153 (25th-75th percentile 97-251) μg/102 (25th-75th percentile 73-138) μg (P= 0.026) when including compensated iodine excretion. Iodine excretion in 24 h urine samples increased with a rising intake of traditional Inuit foods (P= 0.005). Iodine excretion was lower in morning spot urine samples than in 24 h urine samples (P< 0.001). This difference was associated with iodine intake levels (P< 0.001), and was statistically significant when the iodine excretion level was above 150 μg/24 h. In conclusion, the iodine intake level was underestimated from morning spot urine samples if iodine excretion was above the recommended level.

  14. [Iodine nutritional status of the vulnerable population in Henan province in 2011].

    PubMed

    Yang, Jin; Zheng, He-ming; Chen, Gan

    2013-01-01

    To investigate the iodine nutritional status of the vulnerable population in Henan in 2011. From March to December 2011, 44 049 urinary samples of newly married women of childbearing age (363), pregnant women (31 874), lactating women (4893) and children under 2 years (6919) collected from hospitals, maternal and child care hospitals and outpatient department of family planning organizations from 8 cities of Henan province (only including the areas where water iodine was less than 100 µg/L) were tested for urine iodine concentration. The iodine nutritional status of different groups was analyzed. The median of urinary iodine for newly married women, pregnant women, lactating women and children under 2 years was 204.5, 190.9, 145.5 and 185.4 µg/L, respectively (χ(2) = 874.16, P < 0.01). The proportion of urinary iodine below 150 µg/L of pregnant women and below 100 µg/L of lactating women and children under 2 years was 33.0% (10 519/31 874), 24.9% (1218/4893) and 12.4% (855/6919), respectively. The proportion of urinary iodine above 300 µg/L of newly married women was 33.6% (122/363). The median of urinary iodine for pregnant women in the first, second and third trimester was 186.7, 193.8 and 182.5 µg/L, respectively (χ(2) = 55.19, P < 0.01). The median of urinary iodine for the breast-feeding, formula-feeding and mixed-feeding infant under the age of 1 year was 194.8, 85.6 and 176.0 µg/L, respectively (χ(2) = 179.25, P < 0.01). The overall iodine nutrient levels of the vulnerable population in Henan in 2011 were appropriate, but there were still some proportions of pregnant and lactating women with low iodine level. The iodine intake of the formula-feeding infants was not sufficient.

  15. A critical review on iodine presence in drinking water access at the Saharawi refugee camps (Tindouf, Algeria).

    PubMed

    Pichel, N; Vivar, M

    2017-07-01

    Iodine content in drinking water at the Saharawi refugee camps was analysed to assess the controversy in the origin of the prevalence of goitre among this population. A review on the iodine presence in drinking water reported in the literature was conducted, along with international standards and guidelines for iodine intake and iodine concentration in drinking water were also consulted. Chinese legislation was taken as the reference standard to evaluate the iodine concentration in water as adequate (10-150μg/L) or not (high iodine >150μg/L and iodine excess goitre >300μg/L). Water sampling was conducted in 2015 and 2016 at the Saharawi camps (El Aiun, Awserd, Smara, Boujador and Dakhla) and at the institutional capital of Rabouni. The water supply in the camps is organized in three zones: El Aiun and Awserd where each 'wilaya' receives treated water 20days and raw water another 20days; Smara, Rabouni and Boujador receiving treated water continuously and Dakhla receiving raw water continuously. Results show that Smara, Rabouni and Boujador have access to drinking water with adequate iodine levels, as it occurs in Dakhla where raw water meets the Chinese standard, however in El Aiun and Awserd all population should have access to treated water given the current quality of the raw water supply. External supplies of water and animal milk could be also contributing to the high iodine intake. In conclusion, the contribution of drinking water as the main source of iodine to the urinary iodine concentration (UIC) and goitre prevalence among the Saharawi refugee population is not clear. Further studies should be conducted to assess the iodine content among all the nutritional sources of the population with a detailed study on the daily intake of these foods and drinks, including UIC and goitre prevalence studies. Copyright © 2017 Elsevier GmbH. All rights reserved.

  16. High prevalence of iodine deficiency in pregnant women living in adequate iodine area

    PubMed Central

    Mioto, Verônica Carneiro Borges; Monteiro, Ana Carolina de Castro Nassif Gomes; de Camargo, Rosalinda Yossie Asato; Borel, Andréia Rodrigues; Catarino, Regina Maria; Kobayashi, Sergio; Chammas, Maria Cristina; Marui, Suemi

    2018-01-01

    Objectives Iodine deficiency during pregnancy is associated with obstetric and neonatal adverse outcomes. Serum thyroglobulin (sTg) and thyroid volume (TV) are optional tools to urinary iodine concentration (UIC) for defining iodine status. This cross-sectional study aims to evaluate the iodine status of pregnant women living in iodine-adequate area by spot UIC and correlation with sTg, TV and thyroid function. Methods Two hundred and seventy-three pregnant women were evaluated at three trimesters. All had no previous thyroid disease, no iodine supplementation and negative thyroperoxidase and thyroglobulin antibodies. Thyroid function and sTg were measured using electrochemiluminescence immunoassays. TV was determined by ultrasonography; UIC was determined using a modified Sandell–Kolthoff method. Results Median UIC was 146 µg/L, being 52% iodine deficient and only 4% excessive. TSH values were 1.50 ± 0.92, 1.50 ± 0.92 and 1.91 ± 0.96 mIU/L, respectively, in each trimester (P = 0.001). sTg did not change significantly during trimesters with median 11.2 ng/mL and only 3.3% had above 40 ng/mL. Mean TV was 9.3 ± 3.4 mL, which positively correlated with body mass index, but not with sTg. Only 4.5% presented with goitre. When pregnant women were categorized as iodine deficient (UIC < 150 µg/L), adequate (≥150 and <250 µg/L) and excessive (≥250 µg/L), sTg, thyroid hormones and TV at each trimester showed no statistical differences. Conclusions Iodine deficiency was detected frequently in pregnant women living in iodine-adequate area. sTg concentration and TV did not correlate to UIC. Our observation also demonstrated that the Brazilian salt-iodization programme prevents deficiency, but does not maintain iodine status within adequate and recommended ranges for pregnant women. PMID:29700098

  17. High prevalence of iodine deficiency in pregnant women living in adequate iodine area.

    PubMed

    Mioto, Verônica Carneiro Borges; Monteiro, Ana Carolina de Castro Nassif Gomes; de Camargo, Rosalinda Yossie Asato; Borel, Andréia Rodrigues; Catarino, Regina Maria; Kobayashi, Sergio; Chammas, Maria Cristina; Marui, Suemi

    2018-05-01

    Iodine deficiency during pregnancy is associated with obstetric and neonatal adverse outcomes. Serum thyroglobulin (sTg) and thyroid volume (TV) are optional tools to urinary iodine concentration (UIC) for defining iodine status. This cross-sectional study aims to evaluate the iodine status of pregnant women living in iodine-adequate area by spot UIC and correlation with sTg, TV and thyroid function. Two hundred and seventy-three pregnant women were evaluated at three trimesters. All had no previous thyroid disease, no iodine supplementation and negative thyroperoxidase and thyroglobulin antibodies. Thyroid function and sTg were measured using electrochemiluminescence immunoassays. TV was determined by ultrasonography; UIC was determined using a modified Sandell-Kolthoff method. Median UIC was 146 µg/L, being 52% iodine deficient and only 4% excessive. TSH values were 1.50 ± 0.92, 1.50 ± 0.92 and 1.91 ± 0.96 mIU/L, respectively, in each trimester ( P  = 0.001). sTg did not change significantly during trimesters with median 11.2 ng/mL and only 3.3% had above 40 ng/mL. Mean TV was 9.3 ± 3.4 mL, which positively correlated with body mass index, but not with sTg. Only 4.5% presented with goitre.When pregnant women were categorized as iodine deficient (UIC < 150 µg/L), adequate (≥150 and <250 µg/L) and excessive (≥250 µg/L), sTg, thyroid hormones and TV at each trimester showed no statistical differences. Iodine deficiency was detected frequently in pregnant women living in iodine-adequate area. sTg concentration and TV did not correlate to UIC. Our observation also demonstrated that the Brazilian salt-iodization programme prevents deficiency, but does not maintain iodine status within adequate and recommended ranges for pregnant women. © 2018 The authors.

  18. Fast H.264/AVC FRExt intra coding using belief propagation.

    PubMed

    Milani, Simone

    2011-01-01

    In the H.264/AVC FRExt coder, the coding performance of Intra coding significantly overcomes the previous still image coding standards, like JPEG2000, thanks to a massive use of spatial prediction. Unfortunately, the adoption of an extensive set of predictors induces a significant increase of the computational complexity required by the rate-distortion optimization routine. The paper presents a complexity reduction strategy that aims at reducing the computational load of the Intra coding with a small loss in the compression performance. The proposed algorithm relies on selecting a reduced set of prediction modes according to their probabilities, which are estimated adopting a belief-propagation procedure. Experimental results show that the proposed method permits saving up to 60 % of the coding time required by an exhaustive rate-distortion optimization method with a negligible loss in performance. Moreover, it permits an accurate control of the computational complexity unlike other methods where the computational complexity depends upon the coded sequence.

  19. 2,445 Hours of Code: What I Learned from Facilitating Hour of Code Events in High School Libraries

    ERIC Educational Resources Information Center

    Colby, Jennifer

    2015-01-01

    This article describes a school librarian's experience with initiating an Hour of Code event for her school's student body. Hadi Partovi of Code.org conceived the Hour of Code "to get ten million students to try one hour of computer science" (Partovi, 2013a), which is implemented during Computer Science Education Week with a goal of…

  20. Advanced combined iodine dispenser and detector. [for microorganism annihilation in potable water

    NASA Technical Reports Server (NTRS)

    Lantz, J. B.; Schubert, F. H.; Jensen, F. C.; Powell, J. D.

    1977-01-01

    A total weight of 1.23 kg (2.7 lb), a total volume of 1213 cu m (74 cu in), and an average power consumption of 5.5W was achieved in the advanced combined iodine dispenser/detector by integrating the detector with the iodine source, arranging all iodinator components within a compact package and lowering the parasitic power to the detector and electronics circuits. These achievements surpassed the design goals of 1.36 kg (3.0 lb), 1671 cu m (102 cu in) and 8W. The reliability and maintainability were improved by reducing the detector lamp power, using an interchangeable lamp concept, making the electronic circuit boards easily accessible, providing redundant water seals and improving the accessibility to the iodine accumulator for refilling. The system was designed to iodinate (to 5 ppm iodine) the fuel cell water generated during 27 seven-day orbiter missions (equivalent to 18,500 kg (40,700 lb) of water) before the unit must be recharged with iodine crystals.

  1. Influence of dietary iodine on drug-induced hypothyrodism in the rat.

    PubMed

    Beyssen, M L; Lagorce, J F; Cledat, D; Buxeraud, J

    1999-06-01

    Several compounds of pharmaceutical importance from a variety of chemical families, for example chlorpromazine and clomipramine, have been found to form charge-transfer complexes with iodine. We have investigated the influence of dietary iodine on thyroid-gland dysfunction induced by clomipramine, chlorpromazine or 2-thiazoline-2-thiol. We suggest that iodine is partly diverted from its metabolic pathway by complexation with drugs, and so the urinary concentration of iodide is increased. Both chlorpromazine and clomipramine, at doses which do not inhibit thyroperoxidase, enhanced urinary iodine excretion when dietary iodine was restricted (3.944+/-0.96 microg/day for chlorpromazine-tested rats, 3.43+/-1.33 microg/day for clomipramine-tested rats, compared with 2.34+/-0.11 microg/day in control rats). Concurrently, these pharmaceutical compounds increased the level of free thyroid-stimulating hormone (TSH) in comparison with controls and induced histological modifications in, and enlargement of, the thyroid gland. We have demonstrated that drug-induced loss of iodine in the urine was associated with antithyroid action when iodine intake was limited.

  2. Numerical algorithm comparison for the accurate and efficient computation of high-incidence vortical flow

    NASA Technical Reports Server (NTRS)

    Chaderjian, Neal M.

    1991-01-01

    Computations from two Navier-Stokes codes, NSS and F3D, are presented for a tangent-ogive-cylinder body at high angle of attack. Features of this steady flow include a pair of primary vortices on the leeward side of the body as well as secondary vortices. The topological and physical plausibility of this vortical structure is discussed. The accuracy of these codes are assessed by comparison of the numerical solutions with experimental data. The effects of turbulence model, numerical dissipation, and grid refinement are presented. The overall efficiency of these codes are also assessed by examining their convergence rates, computational time per time step, and maximum allowable time step for time-accurate computations. Overall, the numerical results from both codes compared equally well with experimental data, however, the NSS code was found to be significantly more efficient than the F3D code.

  3. User's Manual for FEMOM3DR. Version 1.0

    NASA Technical Reports Server (NTRS)

    Reddy, C. J.

    1998-01-01

    FEMoM3DR is a computer code written in FORTRAN 77 to compute radiation characteristics of antennas on 3D body using combined Finite Element Method (FEM)/Method of Moments (MoM) technique. The code is written to handle different feeding structures like coaxial line, rectangular waveguide, and circular waveguide. This code uses the tetrahedral elements, with vector edge basis functions for FEM and triangular elements with roof-top basis functions for MoM. By virtue of FEM, this code can handle any arbitrary shaped three dimensional bodies with inhomogeneous lossy materials; and due to MoM the computational domain can be terminated in any arbitrary shape. The User's Manual is written to make the user acquainted with the operation of the code. The user is assumed to be familiar with the FORTRAN 77 language and the operating environment of the computers on which the code is intended to run.

  4. Selection of a computer code for Hanford low-level waste engineered-system performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGrail, B.P.; Mahoney, L.A.

    Planned performance assessments for the proposed disposal of low-level waste (LLW) glass produced from remediation of wastes stored in underground tanks at Hanford, Washington will require calculations of radionuclide release rates from the subsurface disposal facility. These calculations will be done with the aid of computer codes. Currently available computer codes were ranked in terms of the feature sets implemented in the code that match a set of physical, chemical, numerical, and functional capabilities needed to assess release rates from the engineered system. The needed capabilities were identified from an analysis of the important physical and chemical process expected tomore » affect LLW glass corrosion and the mobility of radionuclides. The highest ranked computer code was found to be the ARES-CT code developed at PNL for the US Department of Energy for evaluation of and land disposal sites.« less

  5. User's manual for a material transport code on the Octopus Computer Network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naymik, T.G.; Mendez, G.D.

    1978-09-15

    A code to simulate material transport through porous media was developed at Oak Ridge National Laboratory. This code has been modified and adapted for use at Lawrence Livermore Laboratory. This manual, in conjunction with report ORNL-4928, explains the input, output, and execution of the code on the Octopus Computer Network.

  6. Iodised salt and iodine supplements for prenatal and postnatal growth: a rapid scoping of existing systematic reviews.

    PubMed

    Farebrother, Jessica; Naude, Celeste E; Nicol, Liesl; Andersson, Maria; Zimmermann, Michael B

    2015-09-02

    Iodine deficiency can adversely affect child development including stunted growth. However, the effect of iodine supplementation or fortification on prenatal and postnatal growth in children (<18 years) is unclear. We identified the potential need for a systematic review to contribute to the evidence base in this area. To avoid duplication and inform the need for a new systematic review and its protocol, we undertook a rapid scoping review of existing systematic reviews investigating the effect of iodised salt and iodine supplements on growth and other iodine-related outcomes. We searched TRIP and Epistemokinos (latest search date 15 December 2014). All English language systematic reviews reporting on the effect of iodine supplementation or fortification in any form, dose or regimen on any iodine-related health outcomes (including but not limited to growth) were included. Eligible systematic reviews could include experimental or observational studies in pregnant or lactating women or children to age 18. We tabulated the extracted data to capture the scope of questions addressed, including: author, publication year, most recent search date, participants, pre-specified treatment/exposure and comparator, pre-specified outcomes, outcomes relevant to our question and number and type of studies included. Methodological quality of included reviews was assessed using AMSTAR. Nine hundred and seventy-six records were screened and 10 reviews included. Most studies were of moderate methodological quality. Outcomes included assessments of thyroid function, iodine deficiency disorders, mental development and growth. Populations studied included pregnant women, preterm infants and children into adulthood. Most reviews looked at direct iodine supplementation or fortification, though some reviews considered iodine status, including the relationship between iodine intake and iodine biomarkers. Although five reviews pre-specified inclusion of growth outcomes, none provided synthesised evidence on the effects of iodine supplementation or fortification on prenatal and postnatal somatic growth. Our rapid scoping review demonstrates a gap in the evidence base with no existing, up-to-date systematic reviews on the effects of all forms of iodine supplementation/fortification in all of the relevant population groups on relevant growth and growth-related outcomes. A new systematic review examining this question will assist in addressing this gap.

  7. Iodine Supplementation in Women During Preconception, Pregnancy, and Lactation: Current Clinical Practice by U.S. Obstetricians and Midwives.

    PubMed

    De Leo, Simone; Pearce, Elizabeth N; Braverman, Lewis E

    2017-03-01

    Iodine deficiency is a major public-health problem throughout the world, especially for pregnant women, and it is considered the most common cause of preventable intellectual impairment. In the United States, iodine status in pregnant women is considered mildly deficient. Therefore, the Endocrine Society, the American Thyroid Association, the Teratology Society, and the American Academy of Pediatrics recommend that women receive prenatal vitamins containing 150 μg of iodine daily during preconception, pregnancy, and lactation. The objectives of this study were to evaluate awareness of iodine nutrition among obstetricians and midwives in the United States, and to document current clinical practice regarding recommendations for iodine supplementation for women during preconception, pregnancy, and lactation. All midwife members of the American College of Nurse-Midwives (ACNM) and all obstetrician members of the American Medical Association (AMA) were invited to participate in a web-based survey. A total of 199 midwives and 277 obstetricians participated in the survey. One third of both obstetricians and midwives considered iodine status in U.S. pregnant women to be deficient. Although almost all obstetricians and midwives would recommend prenatal multivitamins, most reported rarely or never recommending iodine-containing multivitamins for women planning pregnancy (68.7% and 70.2%, respectively), pregnant women (66% and 67.1%), or lactating women (68.7% and 71.7%). Of the respondents who did report prescribing iodine-containing supplements, 85% recommended supplementation during the first trimester and 75-80% during the second and third trimesters. However, of those who did recommend iodine supplementation, only 45% would prescribe the recommended 150 μg of iodine daily during pregnancy. Overall, 75% of U.S. obstetricians and midwives do not recommend or would recommend an inadequate amount of iodine during preconception, pregnancy, and lactation. Despite the important consequences of iodine deficiency for pregnant women and the recommendations of many medical societies, the majority of U.S. obstetricians and midwives who participated in this survey do not recommend iodine-containing vitamins in women planning pregnancy, during pregnancy, and during lactation.

  8. Performance analysis of three dimensional integral equation computations on a massively parallel computer. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Logan, Terry G.

    1994-01-01

    The purpose of this study is to investigate the performance of the integral equation computations using numerical source field-panel method in a massively parallel processing (MPP) environment. A comparative study of computational performance of the MPP CM-5 computer and conventional Cray-YMP supercomputer for a three-dimensional flow problem is made. A serial FORTRAN code is converted into a parallel CM-FORTRAN code. Some performance results are obtained on CM-5 with 32, 62, 128 nodes along with those on Cray-YMP with a single processor. The comparison of the performance indicates that the parallel CM-FORTRAN code near or out-performs the equivalent serial FORTRAN code for some cases.

  9. Thyroid Function Changes Related to Use of Iodinated Water in United States Space Program

    NASA Technical Reports Server (NTRS)

    McMonigal, Kathleen A.; Braverman, Lewis E.; Dunn, John T.; Stanbury, John B.; Wear, Mary L.; Hamm, Peggy B.; Sauer, Richard L.; Billica, Roger D.; Pool, Sam L.

    1999-01-01

    The National Aeronautics and Space Administration (NASA) has used iodination as a method of microbial disinfection of potable water systems in United States spacecraft and long-duration habitability modules. A review of the effects on the thyroid following consumption o iodinated water by NASA astronauts was conducted. Pharmacological doses of iodine consumed by astronauts transiently decreased thyroid function, as reflected in serum TSH values. Although the adverse effects of excess iodine consumption in susceptible individuals are well documented, exposure to high doses of iodine during space flight did not result in a statistically significant increase in long-term thyroid disease in the astronaut population.

  10. Computer Description of the M561 Utility Truck

    DTIC Science & Technology

    1984-10-01

    GIFT Computer Code Sustainabi1ity Predictions for Army Spare Components Requirements for Combat (SPARC) 20. ABSTRACT (Caotfmia «a NWM eitim ft...used as input to the GIFT computer code to generate target vulnerability data. DO FORM V JAM 73 1473 EDITION OF I NOV 65 IS OBSOLETE Unclass i f ied...anaLyiis requires input from the Geometric Information for Targets ( GIFT ) ’ computer code. This report documents the combina- torial geometry (Com-Geom

  11. TEMPEST: A three-dimensional time-dependent computer program for hydrothermal analysis: Volume 2, Assessment and verification results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eyler, L L; Trent, D S; Budden, M J

    During the course of the TEMPEST computer code development a concurrent effort was conducted to assess the code's performance and the validity of computed results. The results of this work are presented in this document. The principal objective of this effort was to assure the code's computational correctness for a wide range of hydrothermal phenomena typical of fast breeder reactor application. 47 refs., 94 figs., 6 tabs.

  12. Biological monitoring of iodine, a water disinfectant for long-term space missions

    NASA Technical Reports Server (NTRS)

    Zareba, G.; Cernichiari, E.; Goldsmith, L. A.; Clarkson, T. W.

    1995-01-01

    In order to establish guidelines for exposure of astronauts to iodine, used as a water disinfectant in space, we studied the usefulness of hair, saliva, and urine for biological monitoring in humans and in the human hair/nude mouse model. The monitoring of iodine in patients that received 150 mCi of Na131I (carrier-free) showed similar patterns of elimination for blood, saliva, and urine. The mean correlation coefficient (r) between iodine elimination for blood/saliva was 0.99, for blood/urine, 0.95, and for saliva/urine, 0.97. The absolute value of iodine concentrations in urine revealed marked variability, which was corrected by adjusting for creatinine levels. The autoradiographic studies of human hair demonstrated that iodine is rapidly incorporated into external layers of the hair root and can be removed easily during washing. These data were confirmed after iodine exposure using the human hair/nude mouse model. Hair does not provide satisfactory information about exposure due to unstable incorporation of iodine. The most useful medium for biological monitoring of astronauts exposed to high doses of iodine in drinking water is urine, when adjusted for creatinine, and saliva, if quantitative evaluation of flow rate is provided.

  13. [Iodine supply of pregnant women in the Czech Republic].

    PubMed

    Bílek, Radovan; Kaňová, Nataša; Mindžáková, Veronika; Neumann, David; Jiskra, Jan; Ryšavá, Lydie; Zamrazil, Václav

    Iodine deficiency is a global public health problem which is particularly noticeable in pregnant or breastfeeding women and their children. Even mild iodine deficiency during pregnancy can lead to damage to the developing brain and thus affecting the fetus intelligence, his cognitive and neurological function, embryogenesis and growth. In the period 2010-2015 was determined by spectrophotometry at the Institute of Endocrinology the basal urinary iodine in 532 pregnant women at the age of 32 ± 5 (18-44) years, which came from Prague, Hradec Kralove and Mlada Boleslav. It was located 349 women in the first trimester, 112 in the second trimester, and 71 women in the third trimester. In the monitoring of pregnant women in the first trimester 218 basal urine samples of women were determined by mass spectrometry with inductively coupled plasma (ICP MS) in The National Institute of Public Health (NIPH). Women came from the 6 areas in the Czech Republic. Development of urinary iodine in the general population in the period 1994-2015 was observed in patients who underwent Institute of Endocrinology and from population studies conducted in 7 regions of the Czech Republic. It performed 52 648 spectrophotometric analysis of urinary iodine in the general population. Urinary iodine was determined by alkali melting of urine samples, followed by spectrophotometric determination of iodine in the form of iodide using the Sandell-Kolthoff reaction in the Institute of Endocrinology or determination was performed by ICP-MS in the laboratory of NIPH. On average, only 21.8 % of pregnant women had urinary iodine values determined by spectrophotometry higher than 150 μg/L. The results of iodine nutrition of pregnant women in the first trimester analyzed using ICP-MS are better, but even so, only 50.5 % of pregnant women have urinary iodine higher than 150 μg/L. The results of iodine nutrition of pregnant women are alarming, on average, only 30 % of the total of 750 examined women have urinary iodine values greater than 150 μg/L and therefore meet the requirements of the WHO for pregnant women. Our results, however, show that iodine deficiency is not major public health problem in the general population.Key words: ICP-MS - pregnant women - Sandell-Kolthoff reaction - urinary iodine.

  14. Comparison of byproduct formation in waters treated with chlorine and iodine: relevance to point-of-use treatment.

    PubMed

    Smith, Emma Marie; Plewa, Michael J; Lindell, Crystal L; Richardson, Susan D; Mitch, William A

    2010-11-15

    Due to their efficacy in deactivating a range of microbial pathogens, particularly amoebic cysts, iodine-based disinfectants have been a popular option for point-of-use (POU) drinking water disinfection by campers, the military, and rural consumers in developing countries. Recently, concerns regarding the formation of cytotoxic and genotoxic iodinated disinfection byproducts (I-DBPs) have arisen during chloramine disinfection of iodide-containing waters in the developed world; similar concerns should pertain to iodine-based POU disinfection. Because there are alternative POU disinfection techniques, including chlorine-based disinfectants, this paper compared disinfection byproduct formation from a range of iodine-based disinfectants at their recommended dosages to chlorination and chloramination under overdosing conditions. Just as chloroform was the predominant trihalomethane (THM) forme during chlorination or chloramination, iodoform was the predominant THM formed during iodination. Conditions fostering THM formation were similar between these treatments, except that THM formation during chlorination increased with pH, while it was slightly elevated at circumneutral pH during iodination. Iodoform formation during treatment with iodine tincture was higher than during treatment with iodine tablets. On a molar basis, iodoform formation during treatment with iodine tincture was 20-60% of the formation of chloroform during chlorination, and total organic iodine (TOI) formation was twice that of total organic chlorine (TOCl), despite the 6-fold higher oxidant dose during chlorination. Based upon previous measurements of chronic mammalian cell cytotoxicity for the individual THMs, consumers of two waters treated with iodine tincture would receive the same THM-associated cytotoxic exposure in 4-19 days as a consumer of the same waters treated with a 6-fold higher dose of chlorine over 1 year. Iodoacetic acid, diiodoacetic acid, and other iodo-acids were also formed with iodine tincture treatment, but at levels <11% of iodoform. However, testing of a Lifestraw Personal POU device, which combines an iodinated anion exchange resin with activated carbon post-treatment, indicated minimal formation of I-DBPs and no iodine residual. Although N-nitrosamines have been associated with oxidant contact with anion exchange resins, N-nitrosamine formation rapidly declined to low levels (4 ng/L) using the Lifestraw device after the first few flushes of water.

  15. Implementing a wind measurement Doppler Lidar based on a molecular iodine filter to monitor the atmospheric wind field over Beijing

    NASA Astrophysics Data System (ADS)

    Du, Li-fang; Yang, Guo-tao; Wang, Ji-hong; Yue, Chuan; Chen, Lin-xiang

    2017-02-01

    A wind measurement Doppler Lidar system was developed, in which injection seeded laser was used to generate narrow linewidth laser pulse. Frequency stabilization was achieved through absorption of iodine molecules. Commands that control the instrumental system were based on the PID algorithm and coded using VB language. The frequency of the seed laser was locked to iodine molecular absorption line 1109 which is close to the upper edge of the absorption range,with long-time (>4 h) frequency-locking accuracy being ≤0.5 MHz and long-time frequency stability being 3.55×10-9. Design the continuous light velocity measuring system, which concluded the cure about doppler frequency shift and actual speed of chopped wave plate, the velocity error is less than 0.4 m/s. The experiment showed that the stabilized frequency of the seed laser was different from the transmission frequency of the Lidar. And such frequency deviation is known as Chirp of the laser pulse. The real-time measured frequency difference of the continuous and pulsed lights was about 10 MHz, long-time stability deviation was around 5 MHz. When the temporal and spatial resolutions were respectively set to 100 s and 96 m, the wind velocity measurement error of the horizontal wind field at the attitude of 15-35 km was within ±5 m/s, the results showed that the wind measurement Doppler Lidar implemented in Yanqing, Beijing was capable of continuously detecting in the middle and low atmospheric wind field at nighttime. With further development of this technique, system measurement error could be lowered, and long-run routine observations are promising.

  16. Speciation of 127I and 129I in atmospheric aerosols at Risø, Denmark: insight into sources of iodine isotopes and their species transformations

    NASA Astrophysics Data System (ADS)

    Zhang, Luyuan; Hou, Xiaolin; Xu, Sheng

    2016-02-01

    Speciation analysis of iodine in aerosols is a very useful approach for understanding geochemical cycling of iodine in the atmosphere. In this study, overall iodine species, including water-soluble iodine species (iodide, iodate and water-soluble organic iodine), NaOH-soluble iodine, and insoluble iodine have been determined for 129I and 127I in the aerosols collected at Risø, Denmark, during March and May 2011 (shortly after the Fukushima nuclear accident) and in December 2014. The measured concentrations of total iodine are in the range of 1.04-2.48 ng m-3 for 127I and (11.3-97.0) × 105 atoms m-3 for 129I, corresponding to 129I / 127I atomic ratios of (17.8-86.8) × 10-8. The contribution of Fukushima-derived 129I (peak value of 6.3 × 104 atoms m-3) is estimated to be negligible (less than 6 %) compared to the total 129I concentration in northern Europe. The concentrations and species of 129I and 127I in the aerosols are found to be strongly related to their sources and atmospheric pathways. Aerosols that were transported over the contaminated seas contained higher concentrations of 129I than aerosols transported over the European continent. The high 129I concentrations of the marine aerosols are attributed to secondary emission of marine discharged 129I in the contaminated seawater in the North Sea, North Atlantic Ocean, English Channel, Kattegat, etc., rather than direct gaseous release from the European nuclear reprocessing plants (NRPs). Water-soluble iodine was found to be a minor fraction to the total iodine for both 127I (7.8-13.7 %) and 129I (6.5-14.1 %) in ocean-derived aerosols, but accounted for 20.2-30.3 % for 127I and 25.6-29.5 % for 129I in land-derived aerosols. Iodide was the predominant form of water-soluble iodine, accounting for more than 97 % of the water-soluble iodine. NaOH-soluble iodine seems to be independent of the sources of aerosols. The significant proportion of 129I and 127I found in NaOH-soluble fractions is likely bound with organic substances. In contrast to water-soluble iodine, the sources of air masses exerted distinct influences on insoluble iodine for both 129I and 127I, with higher values for marine air masses and lower values for terrestrial air masses.

  17. Spatial variability of drinking water iodine in Denmark: implications for future policy making

    NASA Astrophysics Data System (ADS)

    Voutchkova, Denitza; Ernstsen, Vibeke; Kristiansen, Søren; Hansen, Birgitte

    2014-05-01

    The iodine-an essential component of human thyroid hormones-is provided to our organisms naturally from the food and water and/or is added artificially to the diet. One of the major natural contributors to the dietary iodine intake in Denmark is the drinking water. Both insufficient or excessive iodine intake can cause health problems however the attention falls mainly on the iodine deficiency (ID). Denmark is classified to have mild ID, which is based on sub-national data only. On a bigger scale, in Europe, about 40% of the general population is estimated to suffer from insufficient iodine intake (based on recent update on the iodine status worldwide). A mandatory addition of iodine to the salt was introduced in 2001 in Denmark to address the population's mild deficiency. One of the components of the Danish monitoring program investigating the effect of the salt iodizing (DanThyr) was based on the geographical variation of drinking water iodine levels. More specifically, the location of the two DanThyr cohort studies was chosen to reflect the low concentrations in the western part of Denmark and higher concentration in the eastern part. However, the knowledge about the spatial variability of iodine in Danish ground- and drinking water at that time was quite limited and misrepresentation of the natural variability is suspected. The presented sampling campaign was completed in 2013, and includes 144 waterworks with annual abstraction of about 175 mio m3 groundwater (~45% of the total groundwater abstraction by all active public and private Danish waterworks). The results show a surprisingly complex spatial pattern concerning both the iodine concentrations and speciation. By estimating the dietary iodine intake from water and comparing it to the WHO recommendations, it becomes possible to recognize potentially deficient/excessive geographical areas. Moreover, it is demonstrated that drinking water iodine levels (major dietary iodine contributor in Denmark) can be used as a proxy for the ID status of the population in countries such Denmark, where there is no recent nationwide survey or monitoring program following up the population's iodine status on a national level. Not only can the outcome of this project facilitate the design of future epidemiological studies, but also support policy making in the area of ID prevention and water management as it fills a knowledge gap for drinking water iodine speciation and variation in connection to both spatial distribution and human health.

  18. Method for the simultaneous preparation of Radon-211, Xenon-125, Xenon-123, Astatine-211, Iodine-125 and Iodine-123

    DOEpatents

    Mirzadeh, Saed; Lambrecht, Richard M.

    1987-01-01

    A method for simultaneously preparing Radon-211, Astatine-211, Xenon-125, Xenon-123, Iodine-125 and Iodine-123 in a process that includes irradiating a fertile metal material then using a one-step chemical procedure to collect a first mixture of about equal amounts of Radon-211 and Xenon-125, and a separate second mixture of about equal amounts of Iodine-123 and Astatine-211.

  19. Iodination of Escherichia coli with chloramine T: selective labeling of the outer membrane lipoprotein.

    PubMed Central

    Munford, R S; Gotschlich, E C

    1977-01-01

    Iodination of Escherichia coli cells with chloramine T preferentially labels the free and murein-bound forms of the outer membrane lipoprotein. Iodination for 15 s at 15 degrees C labels the two forms of the lipoprotein almost exclusively, whereas iodination for 60 s at 25 degrees C also labels the other major outer membrane proteins. Chloramine T iodination is a rapid, simple technique for labeling the outer membrane lipoprotein. PMID:400793

  20. Iodine Plasma (Electric Propulsion) Interaction with Spacecraft Materials

    DTIC Science & Technology

    2016-12-28

    fairly resistant to the reactive iodine and iodine plasma . The tantalum heat shielding , though, does react with iodine. DISTRIBUTION A: Distribution...way coupling manner due to the disparate time scales between the electrons (10-10 s ) and plasma (10-3 s ).17,18 Exhaust particles were modeled in two... plasma iodine impacts/m2/ s . Figure 7: iSAT Plume Interaction4 The velocity of both the neutrals and ions impacting the surface will be relatively

Top