Sample records for iris recognition performance

  1. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    NASA Astrophysics Data System (ADS)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  2. Challenging ocular image recognition

    NASA Astrophysics Data System (ADS)

    Pauca, V. Paúl; Forkin, Michael; Xu, Xiao; Plemmons, Robert; Ross, Arun A.

    2011-06-01

    Ocular recognition is a new area of biometric investigation targeted at overcoming the limitations of iris recognition performance in the presence of non-ideal data. There are several advantages for increasing the area beyond the iris, yet there are also key issues that must be addressed such as size of the ocular region, factors affecting performance, and appropriate corpora to study these factors in isolation. In this paper, we explore and identify some of these issues with the goal of better defining parameters for ocular recognition. An empirical study is performed where iris recognition methods are contrasted with texture and point operators on existing iris and face datasets. The experimental results show a dramatic recognition performance gain when additional features are considered in the presence of poor quality iris data, offering strong evidence for extending interest beyond the iris. The experiments also highlight the need for the direct collection of additional ocular imagery.

  3. Iris recognition based on robust principal component analysis

    NASA Astrophysics Data System (ADS)

    Karn, Pradeep; He, Xiao Hai; Yang, Shuai; Wu, Xiao Hong

    2014-11-01

    Iris images acquired under different conditions often suffer from blur, occlusion due to eyelids and eyelashes, specular reflection, and other artifacts. Existing iris recognition systems do not perform well on these types of images. To overcome these problems, we propose an iris recognition method based on robust principal component analysis. The proposed method decomposes all training images into a low-rank matrix and a sparse error matrix, where the low-rank matrix is used for feature extraction. The sparsity concentration index approach is then applied to validate the recognition result. Experimental results using CASIA V4 and IIT Delhi V1iris image databases showed that the proposed method achieved competitive performances in both recognition accuracy and computational efficiency.

  4. Fuzzy difference-of-Gaussian-based iris recognition method for noisy iris images

    NASA Astrophysics Data System (ADS)

    Kang, Byung Jun; Park, Kang Ryoung; Yoo, Jang-Hee; Moon, Kiyoung

    2010-06-01

    Iris recognition is used for information security with a high confidence level because it shows outstanding recognition accuracy by using human iris patterns with high degrees of freedom. However, iris recognition accuracy can be reduced by noisy iris images with optical and motion blurring. We propose a new iris recognition method based on the fuzzy difference-of-Gaussian (DOG) for noisy iris images. This study is novel in three ways compared to previous works: (1) The proposed method extracts iris feature values using the DOG method, which is robust to local variations of illumination and shows fine texture information, including various frequency components. (2) When determining iris binary codes, image noises that cause the quantization error of the feature values are reduced with the fuzzy membership function. (3) The optimal parameters of the DOG filter and the fuzzy membership function are determined in terms of iris recognition accuracy. Experimental results showed that the performance of the proposed method was better than that of previous methods for noisy iris images.

  5. On techniques for angle compensation in nonideal iris recognition.

    PubMed

    Schuckers, Stephanie A C; Schmid, Natalia A; Abhyankar, Aditya; Dorairaj, Vivekanand; Boyce, Christopher K; Hornak, Lawrence A

    2007-10-01

    The popularity of the iris biometric has grown considerably over the past two to three years. Most research has been focused on the development of new iris processing and recognition algorithms for frontal view iris images. However, a few challenging directions in iris research have been identified, including processing of a nonideal iris and iris at a distance. In this paper, we describe two nonideal iris recognition systems and analyze their performance. The word "nonideal" is used in the sense of compensating for off-angle occluded iris images. The system is designed to process nonideal iris images in two steps: 1) compensation for off-angle gaze direction and 2) processing and encoding of the rotated iris image. Two approaches are presented to account for angular variations in the iris images. In the first approach, we use Daugman's integrodifferential operator as an objective function to estimate the gaze direction. After the angle is estimated, the off-angle iris image undergoes geometric transformations involving the estimated angle and is further processed as if it were a frontal view image. The encoding technique developed for a frontal image is based on the application of the global independent component analysis. The second approach uses an angular deformation calibration model. The angular deformations are modeled, and calibration parameters are calculated. The proposed method consists of a closed-form solution, followed by an iterative optimization procedure. The images are projected on the plane closest to the base calibrated plane. Biorthogonal wavelets are used for encoding to perform iris recognition. We use a special dataset of the off-angle iris images to quantify the performance of the designed systems. A series of receiver operating characteristics demonstrate various effects on the performance of the nonideal-iris-based recognition system.

  6. Iris recognition based on key image feature extraction.

    PubMed

    Ren, X; Tian, Q; Zhang, J; Wu, S; Zeng, Y

    2008-01-01

    In iris recognition, feature extraction can be influenced by factors such as illumination and contrast, and thus the features extracted may be unreliable, which can cause a high rate of false results in iris pattern recognition. In order to obtain stable features, an algorithm was proposed in this paper to extract key features of a pattern from multiple images. The proposed algorithm built an iris feature template by extracting key features and performed iris identity enrolment. Simulation results showed that the selected key features have high recognition accuracy on the CASIA Iris Set, where both contrast and illumination variance exist.

  7. Iris Recognition: The Consequences of Image Compression

    NASA Astrophysics Data System (ADS)

    Ives, Robert W.; Bishop, Daniel A.; Du, Yingzi; Belcher, Craig

    2010-12-01

    Iris recognition for human identification is one of the most accurate biometrics, and its employment is expanding globally. The use of portable iris systems, particularly in law enforcement applications, is growing. In many of these applications, the portable device may be required to transmit an iris image or template over a narrow-bandwidth communication channel. Typically, a full resolution image (e.g., VGA) is desired to ensure sufficient pixels across the iris to be confident of accurate recognition results. To minimize the time to transmit a large amount of data over a narrow-bandwidth communication channel, image compression can be used to reduce the file size of the iris image. In other applications, such as the Registered Traveler program, an entire iris image is stored on a smart card, but only 4 kB is allowed for the iris image. For this type of application, image compression is also the solution. This paper investigates the effects of image compression on recognition system performance using a commercial version of the Daugman iris2pi algorithm along with JPEG-2000 compression, and links these to image quality. Using the ICE 2005 iris database, we find that even in the face of significant compression, recognition performance is minimally affected.

  8. An Improved Iris Recognition Algorithm Based on Hybrid Feature and ELM

    NASA Astrophysics Data System (ADS)

    Wang, Juan

    2018-03-01

    The iris image is easily polluted by noise and uneven light. This paper proposed an improved extreme learning machine (ELM) based iris recognition algorithm with hybrid feature. 2D-Gabor filters and GLCM is employed to generate a multi-granularity hybrid feature vector. 2D-Gabor filter and GLCM feature work for capturing low-intermediate frequency and high frequency texture information, respectively. Finally, we utilize extreme learning machine for iris recognition. Experimental results reveal our proposed ELM based multi-granularity iris recognition algorithm (ELM-MGIR) has higher accuracy of 99.86%, and lower EER of 0.12% under the premise of real-time performance. The proposed ELM-MGIR algorithm outperforms other mainstream iris recognition algorithms.

  9. Iris recognition in the presence of ocular disease

    PubMed Central

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-01-01

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology. PMID:19324690

  10. Iris recognition in the presence of ocular disease.

    PubMed

    Aslam, Tariq Mehmood; Tan, Shi Zhuan; Dhillon, Baljean

    2009-05-06

    Iris recognition systems are among the most accurate of all biometric technologies with immense potential for use in worldwide security applications. This study examined the effect of eye pathology on iris recognition and in particular whether eye disease could cause iris recognition systems to fail. The experiment involved a prospective cohort of 54 patients with anterior segment eye disease who were seen at the acute referral unit of the Princess Alexandra Eye Pavilion in Edinburgh. Iris camera images were obtained from patients before treatment was commenced and again at follow-up appointments after treatment had been given. The principal outcome measure was that of mathematical difference in the iris recognition templates obtained from patients' eyes before and after treatment of the eye disease. Results showed that the performance of iris recognition was remarkably resilient to most ophthalmic disease states, including corneal oedema, iridotomies (laser puncture of iris) and conjunctivitis. Problems were, however, encountered in some patients with acute inflammation of the iris (iritis/anterior uveitis). The effects of a subject developing anterior uveitis may cause current recognition systems to fail. Those developing and deploying iris recognition should be aware of the potential problems that this could cause to this key biometric technology.

  11. Novel Approaches to Improve Iris Recognition System Performance Based on Local Quality Evaluation and Feature Fusion

    PubMed Central

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system. PMID:24693243

  12. Novel approaches to improve iris recognition system performance based on local quality evaluation and feature fusion.

    PubMed

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; Chen, Huiling; He, Fei; Pang, Yutong

    2014-01-01

    For building a new iris template, this paper proposes a strategy to fuse different portions of iris based on machine learning method to evaluate local quality of iris. There are three novelties compared to previous work. Firstly, the normalized segmented iris is divided into multitracks and then each track is estimated individually to analyze the recognition accuracy rate (RAR). Secondly, six local quality evaluation parameters are adopted to analyze texture information of each track. Besides, particle swarm optimization (PSO) is employed to get the weights of these evaluation parameters and corresponding weighted coefficients of different tracks. Finally, all tracks' information is fused according to the weights of different tracks. The experimental results based on subsets of three public and one private iris image databases demonstrate three contributions of this paper. (1) Our experimental results prove that partial iris image cannot completely replace the entire iris image for iris recognition system in several ways. (2) The proposed quality evaluation algorithm is a self-adaptive algorithm, and it can automatically optimize the parameters according to iris image samples' own characteristics. (3) Our feature information fusion strategy can effectively improve the performance of iris recognition system.

  13. Iris Matching Based on Personalized Weight Map.

    PubMed

    Dong, Wenbo; Sun, Zhenan; Tan, Tieniu

    2011-09-01

    Iris recognition typically involves three steps, namely, iris image preprocessing, feature extraction, and feature matching. The first two steps of iris recognition have been well studied, but the last step is less addressed. Each human iris has its unique visual pattern and local image features also vary from region to region, which leads to significant differences in robustness and distinctiveness among the feature codes derived from different iris regions. However, most state-of-the-art iris recognition methods use a uniform matching strategy, where features extracted from different regions of the same person or the same region for different individuals are considered to be equally important. This paper proposes a personalized iris matching strategy using a class-specific weight map learned from the training images of the same iris class. The weight map can be updated online during the iris recognition procedure when the successfully recognized iris images are regarded as the new training data. The weight map reflects the robustness of an encoding algorithm on different iris regions by assigning an appropriate weight to each feature code for iris matching. Such a weight map trained by sufficient iris templates is convergent and robust against various noise. Extensive and comprehensive experiments demonstrate that the proposed personalized iris matching strategy achieves much better iris recognition performance than uniform strategies, especially for poor quality iris images.

  14. Improving iris recognition performance using segmentation, quality enhancement, match score fusion, and indexing.

    PubMed

    Vatsa, Mayank; Singh, Richa; Noore, Afzel

    2008-08-01

    This paper proposes algorithms for iris segmentation, quality enhancement, match score fusion, and indexing to improve both the accuracy and the speed of iris recognition. A curve evolution approach is proposed to effectively segment a nonideal iris image using the modified Mumford-Shah functional. Different enhancement algorithms are concurrently applied on the segmented iris image to produce multiple enhanced versions of the iris image. A support-vector-machine-based learning algorithm selects locally enhanced regions from each globally enhanced image and combines these good-quality regions to create a single high-quality iris image. Two distinct features are extracted from the high-quality iris image. The global textural feature is extracted using the 1-D log polar Gabor transform, and the local topological feature is extracted using Euler numbers. An intelligent fusion algorithm combines the textural and topological matching scores to further improve the iris recognition performance and reduce the false rejection rate, whereas an indexing algorithm enables fast and accurate iris identification. The verification and identification performance of the proposed algorithms is validated and compared with other algorithms using the CASIA Version 3, ICE 2005, and UBIRIS iris databases.

  15. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies.

    PubMed

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST's measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform.

  16. VASIR: An Open-Source Research Platform for Advanced Iris Recognition Technologies

    PubMed Central

    Lee, Yooyoung; Micheals, Ross J; Filliben, James J; Phillips, P Jonathon

    2013-01-01

    The performance of iris recognition systems is frequently affected by input image quality, which in turn is vulnerable to less-than-optimal conditions due to illuminations, environments, and subject characteristics (e.g., distance, movement, face/body visibility, blinking, etc.). VASIR (Video-based Automatic System for Iris Recognition) is a state-of-the-art NIST-developed iris recognition software platform designed to systematically address these vulnerabilities. We developed VASIR as a research tool that will not only provide a reference (to assess the relative performance of alternative algorithms) for the biometrics community, but will also advance (via this new emerging iris recognition paradigm) NIST’s measurement mission. VASIR is designed to accommodate both ideal (e.g., classical still images) and less-than-ideal images (e.g., face-visible videos). VASIR has three primary modules: 1) Image Acquisition 2) Video Processing, and 3) Iris Recognition. Each module consists of several sub-components that have been optimized by use of rigorous orthogonal experiment design and analysis techniques. We evaluated VASIR performance using the MBGC (Multiple Biometric Grand Challenge) NIR (Near-Infrared) face-visible video dataset and the ICE (Iris Challenge Evaluation) 2005 still-based dataset. The results showed that even though VASIR was primarily developed and optimized for the less-constrained video case, it still achieved high verification rates for the traditional still-image case. For this reason, VASIR may be used as an effective baseline for the biometrics community to evaluate their algorithm performance, and thus serves as a valuable research platform. PMID:26401431

  17. Cross-sensor iris recognition through kernel learning.

    PubMed

    Pillai, Jaishanker K; Puertas, Maria; Chellappa, Rama

    2014-01-01

    Due to the increasing popularity of iris biometrics, new sensors are being developed for acquiring iris images and existing ones are being continuously upgraded. Re-enrolling users every time a new sensor is deployed is expensive and time-consuming, especially in applications with a large number of enrolled users. However, recent studies show that cross-sensor matching, where the test samples are verified using data enrolled with a different sensor, often lead to reduced performance. In this paper, we propose a machine learning technique to mitigate the cross-sensor performance degradation by adapting the iris samples from one sensor to another. We first present a novel optimization framework for learning transformations on iris biometrics. We then utilize this framework for sensor adaptation, by reducing the distance between samples of the same class, and increasing it between samples of different classes, irrespective of the sensors acquiring them. Extensive evaluations on iris data from multiple sensors demonstrate that the proposed method leads to improvement in cross-sensor recognition accuracy. Furthermore, since the proposed technique requires minimal changes to the iris recognition pipeline, it can easily be incorporated into existing iris recognition systems.

  18. Multispectral iris recognition based on group selection and game theory

    NASA Astrophysics Data System (ADS)

    Ahmad, Foysal; Roy, Kaushik

    2017-05-01

    A commercially available iris recognition system uses only a narrow band of the near infrared spectrum (700-900 nm) while iris images captured in the wide range of 405 nm to 1550 nm offer potential benefits to enhance recognition performance of an iris biometric system. The novelty of this research is that a group selection algorithm based on coalition game theory is explored to select the best patch subsets. In this algorithm, patches are divided into several groups based on their maximum contribution in different groups. Shapley values are used to evaluate the contribution of patches in different groups. Results show that this group selection based iris recognition

  19. Toward More Accurate Iris Recognition Using Cross-Spectral Matching.

    PubMed

    Nalla, Pattabhi Ramaiah; Kumar, Ajay

    2017-01-01

    Iris recognition systems are increasingly deployed for large-scale applications such as national ID programs, which continue to acquire millions of iris images to establish identity among billions. However, with the availability of variety of iris sensors that are deployed for the iris imaging under different illumination/environment, significant performance degradation is expected while matching such iris images acquired under two different domains (either sensor-specific or wavelength-specific). This paper develops a domain adaptation framework to address this problem and introduces a new algorithm using Markov random fields model to significantly improve cross-domain iris recognition. The proposed domain adaptation framework based on the naive Bayes nearest neighbor classification uses a real-valued feature representation, which is capable of learning domain knowledge. Our approach to estimate corresponding visible iris patterns from the synthesis of iris patches in the near infrared iris images achieves outperforming results for the cross-spectral iris recognition. In this paper, a new class of bi-spectral iris recognition system that can simultaneously acquire visible and near infra-red images with pixel-to-pixel correspondences is proposed and evaluated. This paper presents experimental results from three publicly available databases; PolyU cross-spectral iris image database, IIITD CLI and UND database, and achieve outperforming results for the cross-sensor and cross-spectral iris matching.

  20. Enhanced iris recognition method based on multi-unit iris images

    NASA Astrophysics Data System (ADS)

    Shin, Kwang Yong; Kim, Yeong Gon; Park, Kang Ryoung

    2013-04-01

    For the purpose of biometric person identification, iris recognition uses the unique characteristics of the patterns of the iris; that is, the eye region between the pupil and the sclera. When obtaining an iris image, the iris's image is frequently rotated because of the user's head roll toward the left or right shoulder. As the rotation of the iris image leads to circular shifting of the iris features, the accuracy of iris recognition is degraded. To solve this problem, conventional iris recognition methods use shifting of the iris feature codes to perform the matching. However, this increases the computational complexity and level of false acceptance error. To solve these problems, we propose a novel iris recognition method based on multi-unit iris images. Our method is novel in the following five ways compared with previous methods. First, to detect both eyes, we use Adaboost and a rapid eye detector (RED) based on the iris shape feature and integral imaging. Both eyes are detected using RED in the approximate candidate region that consists of the binocular region, which is determined by the Adaboost detector. Second, we classify the detected eyes into the left and right eyes, because the iris patterns in the left and right eyes in the same person are different, and they are therefore considered as different classes. We can improve the accuracy of iris recognition using this pre-classification of the left and right eyes. Third, by measuring the angle of head roll using the two center positions of the left and right pupils, detected by two circular edge detectors, we obtain the information of the iris rotation angle. Fourth, in order to reduce the error and processing time of iris recognition, adaptive bit-shifting based on the measured iris rotation angle is used in feature matching. Fifth, the recognition accuracy is enhanced by the score fusion of the left and right irises. Experimental results on the iris open database of low-resolution images showed that the averaged equal error rate of iris recognition using the proposed method was 4.3006%, which is lower than that of other methods.

  1. Optimal wavelength band clustering for multispectral iris recognition.

    PubMed

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  2. An automatic iris occlusion estimation method based on high-dimensional density estimation.

    PubMed

    Li, Yung-Hui; Savvides, Marios

    2013-04-01

    Iris masks play an important role in iris recognition. They indicate which part of the iris texture map is useful and which part is occluded or contaminated by noisy image artifacts such as eyelashes, eyelids, eyeglasses frames, and specular reflections. The accuracy of the iris mask is extremely important. The performance of the iris recognition system will decrease dramatically when the iris mask is inaccurate, even when the best recognition algorithm is used. Traditionally, people used the rule-based algorithms to estimate iris masks from iris images. However, the accuracy of the iris masks generated this way is questionable. In this work, we propose to use Figueiredo and Jain's Gaussian Mixture Models (FJ-GMMs) to model the underlying probabilistic distributions of both valid and invalid regions on iris images. We also explored possible features and found that Gabor Filter Bank (GFB) provides the most discriminative information for our goal. Finally, we applied Simulated Annealing (SA) technique to optimize the parameters of GFB in order to achieve the best recognition rate. Experimental results show that the masks generated by the proposed algorithm increase the iris recognition rate on both ICE2 and UBIRIS dataset, verifying the effectiveness and importance of our proposed method for iris occlusion estimation.

  3. Improved Iris Recognition through Fusion of Hamming Distance and Fragile Bit Distance.

    PubMed

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2011-12-01

    The most common iris biometric algorithm represents the texture of an iris using a binary iris code. Not all bits in an iris code are equally consistent. A bit is deemed fragile if its value changes across iris codes created from different images of the same iris. Previous research has shown that iris recognition performance can be improved by masking these fragile bits. Rather than ignoring fragile bits completely, we consider what beneficial information can be obtained from the fragile bits. We find that the locations of fragile bits tend to be consistent across different iris codes of the same eye. We present a metric, called the fragile bit distance, which quantitatively measures the coincidence of the fragile bit patterns in two iris codes. We find that score fusion of fragile bit distance and Hamming distance works better for recognition than Hamming distance alone. To our knowledge, this is the first and only work to use the coincidence of fragile bit locations to improve the accuracy of matches.

  4. Feature and Score Fusion Based Multiple Classifier Selection for Iris Recognition

    PubMed Central

    Islam, Md. Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al. PMID:25114676

  5. Feature and score fusion based multiple classifier selection for iris recognition.

    PubMed

    Islam, Md Rabiul

    2014-01-01

    The aim of this work is to propose a new feature and score fusion based iris recognition approach where voting method on Multiple Classifier Selection technique has been applied. Four Discrete Hidden Markov Model classifiers output, that is, left iris based unimodal system, right iris based unimodal system, left-right iris feature fusion based multimodal system, and left-right iris likelihood ratio score fusion based multimodal system, is combined using voting method to achieve the final recognition result. CASIA-IrisV4 database has been used to measure the performance of the proposed system with various dimensions. Experimental results show the versatility of the proposed system of four different classifiers with various dimensions. Finally, recognition accuracy of the proposed system has been compared with existing N hamming distance score fusion approach proposed by Ma et al., log-likelihood ratio score fusion approach proposed by Schmid et al., and single level feature fusion approach proposed by Hollingsworth et al.

  6. Iris recognition as a biometric method after cataract surgery

    PubMed Central

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-01

    Background Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Methods Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. Results A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Conclusions Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure. PMID:14748929

  7. Iris recognition as a biometric method after cataract surgery.

    PubMed

    Roizenblatt, Roberto; Schor, Paulo; Dante, Fabio; Roizenblatt, Jaime; Belfort, Rubens

    2004-01-28

    Biometric methods are security technologies, which use human characteristics for personal identification. Iris recognition systems use iris textures as unique identifiers. This paper presents an analysis of the verification of iris identities after intra-ocular procedures, when individuals were enrolled before the surgery. Fifty-five eyes from fifty-five patients had their irises enrolled before a cataract surgery was performed. They had their irises verified three times before and three times after the procedure, and the Hamming (mathematical) distance of each identification trial was determined, in a controlled ideal biometric environment. The mathematical difference between the iris code before and after the surgery was also compared to a subjective evaluation of the iris anatomy alteration by an experienced surgeon. A correlation between visible subjective iris texture alteration and mathematical difference was verified. We found only six cases in which the eye was no more recognizable, but these eyes were later reenrolled. The main anatomical changes that were found in the new impostor eyes are described. Cataract surgeries change iris textures in such a way that iris recognition systems, which perform mathematical comparisons of textural biometric features, are able to detect these changes and sometimes even discard a pre-enrolled iris considering it an impostor. In our study, re-enrollment proved to be a feasible procedure.

  8. Towards online iris and periocular recognition under relaxed imaging constraints.

    PubMed

    Tan, Chun-Wei; Kumar, Ajay

    2013-10-01

    Online iris recognition using distantly acquired images in a less imaging constrained environment requires the development of a efficient iris segmentation approach and recognition strategy that can exploit multiple features available for the potential identification. This paper presents an effective solution toward addressing such a problem. The developed iris segmentation approach exploits a random walker algorithm to efficiently estimate coarsely segmented iris images. These coarsely segmented iris images are postprocessed using a sequence of operations that can effectively improve the segmentation accuracy. The robustness of the proposed iris segmentation approach is ascertained by providing comparison with other state-of-the-art algorithms using publicly available UBIRIS.v2, FRGC, and CASIA.v4-distance databases. Our experimental results achieve improvement of 9.5%, 4.3%, and 25.7% in the average segmentation accuracy, respectively, for the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with most competing approaches. We also exploit the simultaneously extracted periocular features to achieve significant performance improvement. The joint segmentation and combination strategy suggest promising results and achieve average improvement of 132.3%, 7.45%, and 17.5% in the recognition performance, respectively, from the UBIRIS.v2, FRGC, and CASIA.v4-distance databases, as compared with the related competing approaches.

  9. Contralateral comparison of wavefront-guided LASIK surgery with iris recognition versus without iris recognition using the MEL80 Excimer laser system.

    PubMed

    Wu, Fang; Yang, Yabo; Dougherty, Paul J

    2009-05-01

    To compare outcomes in wavefront-guided LASIK performed with iris recognition software versus without iris recognition software in different eyes of the same patient. A randomised, prospective study of 104 myopic eyes of 52 patients undergoing LASIK surgery with the MEL80 excimer laser system was performed. Iris recognition software was used in one eye of each patient (study group) and not used in the other eye (control group). Higher order aberrations (HOAs), contrast sensitivity, uncorrected vision (UCV), visual acuity (VA) and corneal topography were measured and recorded pre-operatively and at one month and three months post-operatively for each eye. The mean post-operative sphere and cylinder between groups was similar, however the post-operative angles of error (AE) by refraction were significantly smaller in the study group compared to the control group both in arithmetic and absolute means (p = 0.03, p = 0.01). The mean logMAR UCV was significantly better in the study group than in the control group at one month (p = 0.01). The mean logMAR VA was significantly better in the study group than in control group at both one and three months (p = 0.01, p = 0.03). In addition, mean trefoil, total third-order aberration, total fourth-order aberration and the total scotopic root-mean-square (RMS) HOAs were significantly less in the study group than those in the control group at the third (p = 0.01, p = 0.05, p = 0.04, p = 0.02). By three months, the contrast sensitivity had recovered in both groups but the study group performed better at 2.6, 4.2 and 6.6 cpd (cycles per degree) than the control group (p = 0.01, p < 0.01, p = 0.01). LASIK performed with iris recognition results in better VA, lower mean higher-order aberrations, lower refractive post-operative angles of error and better contrast sensitivity at three months post-operatively than LASIK performed without iris recognition.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J; Barstow, Del R; Karakaya, Mahmut

    Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method usesmore » an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.« less

  11. Limbus Impact on Off-angle Iris Degradation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J

    The accuracy of iris recognition depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. Off-angle iris recognition is a new research focus in biometrics that tries to address several issues including corneal refraction, complex 3D iris texture, and blur. In this paper, we present an additional significant challenge that degrades the performance of the off-angle iris recognition systems, called the limbus effect . The limbus is the region at the border of the cornea where the cornea joins the sclera. The limbus is a semitransparent tissue that occludes amore » side portion of the iris plane. The amount of occluded iris texture on the side nearest the camera increases as the image acquisition angle increases. Without considering the role of the limbus effect, it is difficult to design an accurate off-angle iris recognition system. To the best of our knowledge, this is the first work that investigates the limbus effect in detail from a biometrics perspective. Based on results from real images and simulated experiments with real iris texture, the limbus effect increases the hamming distance score between frontal and off-angle iris images ranging from 0.05 to 0.2 depending upon the limbus height.« less

  12. Real-time image restoration for iris recognition systems.

    PubMed

    Kang, Byung Jun; Park, Kang Ryoung

    2007-12-01

    In the field of biometrics, it has been reported that iris recognition techniques have shown high levels of accuracy because unique patterns of the human iris, which has very many degrees of freedom, are used. However, because conventional iris cameras have small depth-of-field (DOF) areas, input iris images can easily be blurred, which can lead to lower recognition performance, since iris patterns are transformed by the blurring caused by optical defocusing. To overcome these problems, an autofocusing camera can be used. However, this inevitably increases the cost, size, and complexity of the system. Therefore, we propose a new real-time iris image-restoration method, which can increase the camera's DOF without requiring any additional hardware. This paper presents five novelties as compared to previous works: 1) by excluding eyelash and eyelid regions, it is possible to obtain more accurate focus scores from input iris images; 2) the parameter of the point spread function (PSF) can be estimated in terms of camera optics and measured focus scores; therefore, parameter estimation is more accurate than it has been in previous research; 3) because the PSF parameter can be obtained by using a predetermined equation, iris image restoration can be done in real-time; 4) by using a constrained least square (CLS) restoration filter that considers noise, performance can be greatly enhanced; and 5) restoration accuracy can also be enhanced by estimating the weight value of the noise-regularization term of the CLS filter according to the amount of image blurring. Experimental results showed that iris recognition errors when using the proposed restoration method were greatly reduced as compared to those results achieved without restoration or those achieved using previous iris-restoration methods.

  13. Trade off between variable and fixed size normalization in orthogonal polynomials based iris recognition system.

    PubMed

    Krishnamoorthi, R; Anna Poorani, G

    2016-01-01

    Iris normalization is an important stage in any iris biometric, as it has a propensity to trim down the consequences of iris distortion. To indemnify the variation in size of the iris owing to the action of stretching or enlarging the pupil in iris acquisition process and camera to eyeball distance, two normalization schemes has been proposed in this work. In the first method, the iris region of interest is normalized by converting the iris into the variable size rectangular model in order to avoid the under samples near the limbus border. In the second method, the iris region of interest is normalized by converting the iris region into a fixed size rectangular model in order to avoid the dimensional discrepancies between the eye images. The performance of the proposed normalization methods is evaluated with orthogonal polynomials based iris recognition in terms of FAR, FRR, GAR, CRR and EER.

  14. Iris segmentation using an edge detector based on fuzzy sets theory and cellular learning automata.

    PubMed

    Ghanizadeh, Afshin; Abarghouei, Amir Atapour; Sinaie, Saman; Saad, Puteh; Shamsuddin, Siti Mariyam

    2011-07-01

    Iris-based biometric systems identify individuals based on the characteristics of their iris, since they are proven to remain unique for a long time. An iris recognition system includes four phases, the most important of which is preprocessing in which the iris segmentation is performed. The accuracy of an iris biometric system critically depends on the segmentation system. In this paper, an iris segmentation system using edge detection techniques and Hough transforms is presented. The newly proposed edge detection system enhances the performance of the segmentation in a way that it performs much more efficiently than the other conventional iris segmentation methods.

  15. Evaluation of iris recognition system for wavefront-guided laser in situ keratomileusis for myopic astigmatism.

    PubMed

    Ghosh, Sudipta; Couper, Terry A; Lamoureux, Ecosse; Jhanji, Vishal; Taylor, Hugh R; Vajpayee, Rasik B

    2008-02-01

    To evaluate the visual and refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) using an iris recognition system for the correction of myopic astigmatism. Centre for Eye Research Australia, Melbourne Excimer Laser Research Group, and Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. A comparative analysis of wavefront-guided LASIK was performed with an iris recognition system (iris recognition group) and without iris recognition (control group). The main parameters were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, amount of residual cylinder, manifest spherical equivalent (SE), and the index of success using the Alpins method of astigmatism analysis 1 and 3 months postoperatively. A P value less than 0.05 was considered statistically significant. Preoperatively, the mean SE was -4.32 diopters (D) +/- 1.59 (SD) in the iris recognition group (100 eyes) and -4.55 +/- 1.87 D in the control group (98 eyes) (P = .84). At 3 months, the mean SE was -0.05 +/- 0.21 D and -0.20 +/- 0.40 D, respectively (P = .001), and an SE within +/-0.50 D of emmetropia was achieved in 92.0% and 85.7% of eyes, respectively (P = .07). At 3 months, the UCVA was 20/20 or better in 90.0% and 76.5% of eyes, respectively. A statistically significant difference in the amount of astigmatic correction was seen between the 2 groups (P = .00 and P = .01 at 1 and 3 months, respectively). The index of success was 98.0% in the iris recognition group and 81.6% in the control group (P = .03). Iris recognition software may achieve better visual and refractive outcomes in wavefront-guided LASIK for myopic astigmatism.

  16. Design method of ARM based embedded iris recognition system

    NASA Astrophysics Data System (ADS)

    Wang, Yuanbo; He, Yuqing; Hou, Yushi; Liu, Ting

    2008-03-01

    With the advantages of non-invasiveness, uniqueness, stability and low false recognition rate, iris recognition has been successfully applied in many fields. Up to now, most of the iris recognition systems are based on PC. However, a PC is not portable and it needs more power. In this paper, we proposed an embedded iris recognition system based on ARM. Considering the requirements of iris image acquisition and recognition algorithm, we analyzed the design method of the iris image acquisition module, designed the ARM processing module and its peripherals, studied the Linux platform and the recognition algorithm based on this platform, finally actualized the design method of ARM-based iris imaging and recognition system. Experimental results show that the ARM platform we used is fast enough to run the iris recognition algorithm, and the data stream can flow smoothly between the camera and the ARM chip based on the embedded Linux system. It's an effective method of using ARM to actualize portable embedded iris recognition system.

  17. Cataract influence on iris recognition performance

    NASA Astrophysics Data System (ADS)

    Trokielewicz, Mateusz; Czajka, Adam; Maciejewicz, Piotr

    2014-11-01

    This paper presents the experimental study revealing weaker performance of the automatic iris recognition methods for cataract-affected eyes when compared to healthy eyes. There is little research on the topic, mostly incorporating scarce databases that are often deficient in images representing more than one illness. We built our own database, acquiring 1288 eye images of 37 patients of the Medical University of Warsaw. Those images represent several common ocular diseases, such as cataract, along with less ordinary conditions, such as iris pattern alterations derived from illness or eye trauma. Images were captured in near-infrared light (used in biometrics) and for selected cases also in visible light (used in ophthalmological diagnosis). Since cataract is a disorder that is most populated by samples in the database, in this paper we focus solely on this illness. To assess the extent of the performance deterioration we use three iris recognition methodologies (commercial and academic solutions) to calculate genuine match scores for healthy eyes and those influenced by cataract. Results show a significant degradation in iris recognition reliability manifesting by worsening the genuine scores in all three matchers used in this study (12% of genuine score increase for an academic matcher, up to 175% of genuine score increase obtained for an example commercial matcher). This increase in genuine scores affected the final false non-match rate in two matchers. To our best knowledge this is the only study of such kind that employs more than one iris matcher, and analyzes the iris image segmentation as a potential source of decreased reliability

  18. Iris unwrapping using the Bresenham circle algorithm for real-time iris recognition

    NASA Astrophysics Data System (ADS)

    Carothers, Matthew T.; Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.

    2015-02-01

    An efficient parallel architecture design for the iris unwrapping process in a real-time iris recognition system using the Bresenham Circle Algorithm is presented in this paper. Based on the characteristics of the model parameters this algorithm was chosen over the widely used polar conversion technique as the iris unwrapping model. The architecture design is parallelized to increase the throughput of the system and is suitable for processing an inputted image size of 320 × 240 pixels in real-time using Field Programmable Gate Array (FPGA) technology. Quartus software is used to implement, verify, and analyze the design's performance using the VHSIC Hardware Description Language. The system's predicted processing time is faster than the modern iris unwrapping technique used today∗.

  19. Support Vector Machine Based on Adaptive Acceleration Particle Swarm Optimization

    PubMed Central

    Abdulameer, Mohammed Hasan; Othman, Zulaiha Ali

    2014-01-01

    Existing face recognition methods utilize particle swarm optimizer (PSO) and opposition based particle swarm optimizer (OPSO) to optimize the parameters of SVM. However, the utilization of random values in the velocity calculation decreases the performance of these techniques; that is, during the velocity computation, we normally use random values for the acceleration coefficients and this creates randomness in the solution. To address this problem, an adaptive acceleration particle swarm optimization (AAPSO) technique is proposed. To evaluate our proposed method, we employ both face and iris recognition based on AAPSO with SVM (AAPSO-SVM). In the face and iris recognition systems, performance is evaluated using two human face databases, YALE and CASIA, and the UBiris dataset. In this method, we initially perform feature extraction and then recognition on the extracted features. In the recognition process, the extracted features are used for SVM training and testing. During the training and testing, the SVM parameters are optimized with the AAPSO technique, and in AAPSO, the acceleration coefficients are computed using the particle fitness values. The parameters in SVM, which are optimized by AAPSO, perform efficiently for both face and iris recognition. A comparative analysis between our proposed AAPSO-SVM and the PSO-SVM technique is presented. PMID:24790584

  20. Iris Location Algorithm Based on the CANNY Operator and Gradient Hough Transform

    NASA Astrophysics Data System (ADS)

    Zhong, L. H.; Meng, K.; Wang, Y.; Dai, Z. Q.; Li, S.

    2017-12-01

    In the iris recognition system, the accuracy of the localization of the inner and outer edges of the iris directly affects the performance of the recognition system, so iris localization has important research meaning. Our iris data contain eyelid, eyelashes, light spot and other noise, even the gray transformation of the images is not obvious, so the general methods of iris location are unable to realize the iris location. The method of the iris location based on Canny operator and gradient Hough transform is proposed. Firstly, the images are pre-processed; then, calculating the gradient information of images, the inner and outer edges of iris are coarse positioned using Canny operator; finally, according to the gradient Hough transform to realize precise localization of the inner and outer edge of iris. The experimental results show that our algorithm can achieve the localization of the inner and outer edges of the iris well, and the algorithm has strong anti-interference ability, can greatly reduce the location time and has higher accuracy and stability.

  1. Iris-based medical analysis by geometric deformation features.

    PubMed

    Ma, Lin; Zhang, D; Li, Naimin; Cai, Yan; Zuo, Wangmeng; Wang, Kuanguan

    2013-01-01

    Iris analysis studies the relationship between human health and changes in the anatomy of the iris. Apart from the fact that iris recognition focuses on modeling the overall structure of the iris, iris diagnosis emphasizes the detecting and analyzing of local variations in the characteristics of irises. This paper focuses on studying the geometrical structure changes in irises that are caused by gastrointestinal diseases, and on measuring the observable deformations in the geometrical structures of irises that are related to roundness, diameter and other geometric forms of the pupil and the collarette. Pupil and collarette based features are defined and extracted. A series of experiments are implemented on our experimental pathological iris database, including manual clustering of both normal and pathological iris images, manual classification by non-specialists, manual classification by individuals with a medical background, classification ability verification for the proposed features, and disease recognition by applying the proposed features. The results prove the effectiveness and clinical diagnostic significance of the proposed features and a reliable recognition performance for automatic disease diagnosis. Our research results offer a novel systematic perspective for iridology studies and promote the progress of both theoretical and practical work in iris diagnosis.

  2. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor

    PubMed Central

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-01-01

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies. PMID:29695113

  3. Presentation Attack Detection for Iris Recognition System Using NIR Camera Sensor.

    PubMed

    Nguyen, Dat Tien; Baek, Na Rae; Pham, Tuyen Danh; Park, Kang Ryoung

    2018-04-24

    Among biometric recognition systems such as fingerprint, finger-vein, or face, the iris recognition system has proven to be effective for achieving a high recognition accuracy and security level. However, several recent studies have indicated that an iris recognition system can be fooled by using presentation attack images that are recaptured using high-quality printed images or by contact lenses with printed iris patterns. As a result, this potential threat can reduce the security level of an iris recognition system. In this study, we propose a new presentation attack detection (PAD) method for an iris recognition system (iPAD) using a near infrared light (NIR) camera image. To detect presentation attack images, we first localized the iris region of the input iris image using circular edge detection (CED). Based on the result of iris localization, we extracted the image features using deep learning-based and handcrafted-based methods. The input iris images were then classified into real and presentation attack categories using support vector machines (SVM). Through extensive experiments with two public datasets, we show that our proposed method effectively solves the iris recognition presentation attack detection problem and produces detection accuracy superior to previous studies.

  4. Reliability of automatic biometric iris recognition after phacoemulsification or drug-induced pupil dilation.

    PubMed

    Seyeddain, Orang; Kraker, Hannes; Redlberger, Andreas; Dexl, Alois K; Grabner, Günther; Emesz, Martin

    2014-01-01

    To investigate the reliability of a biometric iris recognition system for personal authentication after cataract surgery or iatrogenic pupil dilation. This was a prospective, nonrandomized, single-center, cohort study for evaluating the performance of an iris recognition system 2-24 hours after phacoemulsification and intraocular lens implantation (group 1) and before and after iatrogenic pupil dilation (group 2). Of the 173 eyes that could be enrolled before cataract surgery, 164 (94.8%) were easily recognized postoperatively, whereas in 9 (5.2%) this was not possible. However, these 9 eyes could be reenrolled and afterwards recognized successfully. In group 2, of a total of 184 eyes that were enrolled in miosis, a total of 22 (11.9%) could not be recognized in mydriasis and therefore needed reenrollment. No single case of false-positive acceptance occurred in either group. The results of this trial indicate that standard cataract surgery seems not to be a limiting factor for iris recognition in the large majority of cases. Some patients (5.2% in this study) might need "reenrollment" after cataract surgery. Iris recognition was primarily successful in eyes with medically dilated pupils in nearly 9 out of 10 eyes. No single case of false-positive acceptance occurred in either group in this trial. It seems therefore that iris recognition is a valid biometric method in the majority of cases after cataract surgery or after pupil dilation.

  5. Heterogeneous iris image hallucination using sparse representation on a learned heterogeneous patch dictionary

    NASA Astrophysics Data System (ADS)

    Li, Yung-Hui; Zheng, Bo-Ren; Ji, Dai-Yan; Tien, Chung-Hao; Liu, Po-Tsun

    2014-09-01

    Cross sensor iris matching may seriously degrade the recognition performance because of the sensor mis-match problem of iris images between the enrollment and test stage. In this paper, we propose two novel patch-based heterogeneous dictionary learning method to attack this problem. The first method applies the latest sparse representation theory while the second method tries to learn the correspondence relationship through PCA in heterogeneous patch space. Both methods learn the basic atoms in iris textures across different image sensors and build connections between them. After such connections are built, at test stage, it is possible to hallucinate (synthesize) iris images across different sensors. By matching training images with hallucinated images, the recognition rate can be successfully enhanced. The experimental results showed the satisfied results both visually and in terms of recognition rate. Experimenting with an iris database consisting of 3015 images, we show that the EER is decreased 39.4% relatively by the proposed method.

  6. Biometric iris image acquisition system with wavefront coding technology

    NASA Astrophysics Data System (ADS)

    Hsieh, Sheng-Hsun; Yang, Hsi-Wen; Huang, Shao-Hung; Li, Yung-Hui; Tien, Chung-Hao

    2013-09-01

    Biometric signatures for identity recognition have been practiced for centuries. Basically, the personal attributes used for a biometric identification system can be classified into two areas: one is based on physiological attributes, such as DNA, facial features, retinal vasculature, fingerprint, hand geometry, iris texture and so on; the other scenario is dependent on the individual behavioral attributes, such as signature, keystroke, voice and gait style. Among these features, iris recognition is one of the most attractive approaches due to its nature of randomness, texture stability over a life time, high entropy density and non-invasive acquisition. While the performance of iris recognition on high quality image is well investigated, not too many studies addressed that how iris recognition performs subject to non-ideal image data, especially when the data is acquired in challenging conditions, such as long working distance, dynamical movement of subjects, uncontrolled illumination conditions and so on. There are three main contributions in this paper. Firstly, the optical system parameters, such as magnification and field of view, was optimally designed through the first-order optics. Secondly, the irradiance constraints was derived by optical conservation theorem. Through the relationship between the subject and the detector, we could estimate the limitation of working distance when the camera lens and CCD sensor were known. The working distance is set to 3m in our system with pupil diameter 86mm and CCD irradiance 0.3mW/cm2. Finally, We employed a hybrid scheme combining eye tracking with pan and tilt system, wavefront coding technology, filter optimization and post signal recognition to implement a robust iris recognition system in dynamic operation. The blurred image was restored to ensure recognition accuracy over 3m working distance with 400mm focal length and aperture F/6.3 optics. The simulation result as well as experiment validates the proposed code apertured imaging system, where the imaging volume was 2.57 times extended over the traditional optics, while keeping sufficient recognition accuracy.

  7. [Comparative clinical study of wavefront-guided laser in situ keratomileusis with versus without iris recognition for myopia or myopic astigmatism].

    PubMed

    Wang, Wei-qun; Zhang, Jin-song; Zhao, Xiao-jin

    2011-10-01

    To explore the postoperative visual acuity results of wavefront-guided LASIK with iris recognition for myopia or myopic astigmatism and the changes of higher-order aberrations and contrast sensitivity function (CSF). Series of prospective case studies, 158 eyes (85 cases) of myopia or myopic astigmatism were divided into two groups: one group underwent wavefront-guided LASIK with iris recognition (iris recognition group); another group underwent wavefront-guided LASIK treatment without iris recognition through the limbus maring point (non-iris recognition group). To comparative analyze the postoperative visual acuity, residual refraction, the RMS of higher-order aberrations and CSF of two groups. There was no statistical significance difference between two groups of the average uncorrected visual acuity (t = 0.039, 0.058, 0.898; P = 0.844, 0.810, 0.343), best corrected visual acuity (t = 0.320, 0.440, 1.515; P = 0.572, 0.507, 0.218), and residual refraction [spherical equivalent (t = 0.027, 0.215, 0.238; P = 0.869, 0.643, 0.626), spherical (t = 0.145, 0.117, 0.038; P = 0.704, 0.732, 0.845) and cylinder (t = 1.676, 1.936, 0.334; P = 0.195, 0.164, 0.563)] at postoperative 10 days, 1 month and 3 month. The security index of iris recognition group at postoperative 3 month was 1.06 and non-iris recognition group was 1.03; the efficacy index of iris recognition group is 1.01 and non-iris recognition group was 1.00. Postoperative 3 month iris recognition group 93.83% eyes and non-iris recognition group of 90.91% eyes spherical equivalent within ± 0.50 D (χ(2) = 0.479, P = 0.489), iris recognition group of 98.77% eyes and non-iris recognition group of 97.40% eyes spherical equivalent within ± 1.00 D (Fisher test, P = 0.613). There was no significance difference between the two groups of security, efficacy and predictability. Non-iris recognition group postoperative 1 month and postoperative 3 months 3-order order aberrations root mean square value (RMS) higher than the iris recognition group increased (t = 3.414, -2.870; P = 0.027, 0.045), in particular of coma; the general higher-order aberrations (t = 0.386, 1.132; P = 0.719, 0.321), 4-order aberrations (t = 0.808, 2.720; P = 0.464, 0.063), and 5-order aberrations (t = 0.148, -1.717; P = 0.890, 0.161) show no statistically significant difference. Three months after surgery, two groups have recovered at all spatial frequencies of CSF, iris recognition group at 3.0 c/d (t = 3.209, P = 0.002) and 6.0 c/d (t = 2.997, P = 0.004) spatial frequencies of CSF under mesopic condition was better than non-iris recognition group, glare contrast sensitivity function (GCSF) for 3.0 c/d (t = 3.423, P = 0.001) and 6.0 c/d (t = 6.986, P = 0.000) spatial frequencies under mesopic condition and 1.5 c/d (t = 9.839, P = 0.000) and 3.0 c/d (t = 7.367, P = 0.000) spatial frequencies under photopic condition in iris recognition group were better than non-iris recognition group, there were no significant difference between two groups at the other spatial frequencies. Wavefront-guided LASIK with or without iris recognition both acquired better postoperative visual acuity, but in comparison with without iris recognition, wavefront-guided LASIK with iris recognition is efficient to reduce coma and enhance contrast sensitivity of postoperative.

  8. The fast iris image clarity evaluation based on Tenengrad and ROI selection

    NASA Astrophysics Data System (ADS)

    Gao, Shuqin; Han, Min; Cheng, Xu

    2018-04-01

    In iris recognition system, the clarity of iris image is an important factor that influences recognition effect. In the process of recognition, the blurred image may possibly be rejected by the automatic iris recognition system, which will lead to the failure of identification. Therefore it is necessary to evaluate the iris image definition before recognition. Considered the existing evaluation methods on iris image definition, we proposed a fast algorithm to evaluate the definition of iris image in this paper. In our algorithm, firstly ROI (Region of Interest) is extracted based on the reference point which is determined by using the feature of the light spots within the pupil, then Tenengrad operator is used to evaluate the iris image's definition. Experiment results show that, the iris image definition algorithm proposed in this paper could accurately distinguish the iris images of different clarity, and the algorithm has the merit of low computational complexity and more effectiveness.

  9. Point spread function engineering for iris recognition system design.

    PubMed

    Ashok, Amit; Neifeld, Mark A

    2010-04-01

    Undersampling in the detector array degrades the performance of iris-recognition imaging systems. We find that an undersampling of 8 x 8 reduces the iris-recognition performance by nearly a factor of 4 (on CASIA iris database), as measured by the false rejection ratio (FRR) metric. We employ optical point spread function (PSF) engineering via a Zernike phase mask in conjunction with multiple subpixel shifted image measurements (frames) to mitigate the effect of undersampling. A task-specific optimization framework is used to engineer the optical PSF and optimize the postprocessing parameters to minimize the FRR. The optimized Zernike phase enhanced lens (ZPEL) imager design with one frame yields an improvement of nearly 33% relative to a thin observation module by bounded optics (TOMBO) imager with one frame. With four frames the optimized ZPEL imager achieves a FRR equal to that of the conventional imager without undersampling. Further, the ZPEL imager design using 16 frames yields a FRR that is actually 15% lower than that obtained with the conventional imager without undersampling.

  10. Increasing the information acquisition volume in iris recognition systems.

    PubMed

    Barwick, D Shane

    2008-09-10

    A significant hurdle for the widespread adoption of iris recognition in security applications is that the typically small imaging volume for eye placement results in systems that are not user friendly. Separable cubic phase plates at the lens pupil have been shown to ameliorate this disadvantage by increasing the depth of field. However, these phase masks have limitations on how efficiently they can capture the information-bearing spatial frequencies in iris images. The performance gains in information acquisition that can be achieved by more general, nonseparable phase masks is demonstrated. A detailed design method is presented, and simulations using representative designs allow for performance comparisons.

  11. Iris double recognition based on modified evolutionary neural network

    NASA Astrophysics Data System (ADS)

    Liu, Shuai; Liu, Yuan-Ning; Zhu, Xiao-Dong; Huo, Guang; Liu, Wen-Tao; Feng, Jia-Kai

    2017-11-01

    Aiming at multicategory iris recognition under illumination and noise interference, this paper proposes a method of iris double recognition based on a modified evolutionary neural network. An equalization histogram and Laplace of Gaussian operator are used to process the iris to suppress illumination and noise interference and Haar wavelet to convert the iris feature to binary feature encoding. Calculate the Hamming distance for the test iris and template iris , and compare with classification threshold, determine the type of iris. If the iris cannot be identified as a different type, there needs to be a secondary recognition. The connection weights in back-propagation (BP) neural network use modified evolutionary neural network to adaptively train. The modified neural network is composed of particle swarm optimization with mutation operator and BP neural network. According to different iris libraries in different circumstances of experimental results, under illumination and noise interference, the correct recognition rate of this algorithm is higher, the ROC curve is closer to the coordinate axis, the training and recognition time is shorter, and the stability and the robustness are better.

  12. Efficient iris recognition by characterizing key local variations.

    PubMed

    Ma, Li; Tan, Tieniu; Wang, Yunhong; Zhang, Dexin

    2004-06-01

    Unlike other biometrics such as fingerprints and face, the distinct aspect of iris comes from randomly distributed features. This leads to its high reliability for personal identification, and at the same time, the difficulty in effectively representing such details in an image. This paper describes an efficient algorithm for iris recognition by characterizing key local variations. The basic idea is that local sharp variation points, denoting the appearing or vanishing of an important image structure, are utilized to represent the characteristics of the iris. The whole procedure of feature extraction includes two steps: 1) a set of one-dimensional intensity signals is constructed to effectively characterize the most important information of the original two-dimensional image; 2) using a particular class of wavelets, a position sequence of local sharp variation points in such signals is recorded as features. We also present a fast matching scheme based on exclusive OR operation to compute the similarity between a pair of position sequences. Experimental results on 2255 iris images show that the performance of the proposed method is encouraging and comparable to the best iris recognition algorithm found in the current literature.

  13. Noisy Ocular Recognition Based on Three Convolutional Neural Networks.

    PubMed

    Lee, Min Beom; Hong, Hyung Gil; Park, Kang Ryoung

    2017-12-17

    In recent years, the iris recognition system has been gaining increasing acceptance for applications such as access control and smartphone security. When the images of the iris are obtained under unconstrained conditions, an issue of undermined quality is caused by optical and motion blur, off-angle view (the user's eyes looking somewhere else, not into the front of the camera), specular reflection (SR) and other factors. Such noisy iris images increase intra-individual variations and, as a result, reduce the accuracy of iris recognition. A typical iris recognition system requires a near-infrared (NIR) illuminator along with an NIR camera, which are larger and more expensive than fingerprint recognition equipment. Hence, many studies have proposed methods of using iris images captured by a visible light camera without the need for an additional illuminator. In this research, we propose a new recognition method for noisy iris and ocular images by using one iris and two periocular regions, based on three convolutional neural networks (CNNs). Experiments were conducted by using the noisy iris challenge evaluation-part II (NICE.II) training dataset (selected from the university of Beira iris (UBIRIS).v2 database), mobile iris challenge evaluation (MICHE) database, and institute of automation of Chinese academy of sciences (CASIA)-Iris-Distance database. As a result, the method proposed by this study outperformed previous methods.

  14. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors

    PubMed Central

    Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung

    2018-01-01

    The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets. PMID:29748495

  15. IrisDenseNet: Robust Iris Segmentation Using Densely Connected Fully Convolutional Networks in the Images by Visible Light and Near-Infrared Light Camera Sensors.

    PubMed

    Arsalan, Muhammad; Naqvi, Rizwan Ali; Kim, Dong Seop; Nguyen, Phong Ha; Owais, Muhammad; Park, Kang Ryoung

    2018-05-10

    The recent advancements in computer vision have opened new horizons for deploying biometric recognition algorithms in mobile and handheld devices. Similarly, iris recognition is now much needed in unconstraint scenarios with accuracy. These environments make the acquired iris image exhibit occlusion, low resolution, blur, unusual glint, ghost effect, and off-angles. The prevailing segmentation algorithms cannot cope with these constraints. In addition, owing to the unavailability of near-infrared (NIR) light, iris recognition in visible light environment makes the iris segmentation challenging with the noise of visible light. Deep learning with convolutional neural networks (CNN) has brought a considerable breakthrough in various applications. To address the iris segmentation issues in challenging situations by visible light and near-infrared light camera sensors, this paper proposes a densely connected fully convolutional network (IrisDenseNet), which can determine the true iris boundary even with inferior-quality images by using better information gradient flow between the dense blocks. In the experiments conducted, five datasets of visible light and NIR environments were used. For visible light environment, noisy iris challenge evaluation part-II (NICE-II selected from UBIRIS.v2 database) and mobile iris challenge evaluation (MICHE-I) datasets were used. For NIR environment, the institute of automation, Chinese academy of sciences (CASIA) v4.0 interval, CASIA v4.0 distance, and IIT Delhi v1.0 iris datasets were used. Experimental results showed the optimal segmentation of the proposed IrisDenseNet and its excellent performance over existing algorithms for all five datasets.

  16. An effective approach for iris recognition using phase-based image matching.

    PubMed

    Miyazawa, Kazuyuki; Ito, Koichi; Aoki, Takafumi; Kobayashi, Koji; Nakajima, Hiroshi

    2008-10-01

    This paper presents an efficient algorithm for iris recognition using phase-based image matching--an image matching technique using phase components in 2D Discrete Fourier Transforms (DFTs) of given images. Experimental evaluation using CASIA iris image databases (versions 1.0 and 2.0) and Iris Challenge Evaluation (ICE) 2005 database clearly demonstrates that the use of phase components of iris images makes possible to achieve highly accurate iris recognition with a simple matching algorithm. This paper also discusses major implementation issues of our algorithm. In order to reduce the size of iris data and to prevent the visibility of iris images, we introduce the idea of 2D Fourier Phase Code (FPC) for representing iris information. The 2D FPC is particularly useful for implementing compact iris recognition devices using state-of-the-art Digital Signal Processing (DSP) technology.

  17. Shape Adaptive, Robust Iris Feature Extraction from Noisy Iris Images

    PubMed Central

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-01-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate. PMID:24696801

  18. Shape adaptive, robust iris feature extraction from noisy iris images.

    PubMed

    Ghodrati, Hamed; Dehghani, Mohammad Javad; Danyali, Habibolah

    2013-10-01

    In the current iris recognition systems, noise removing step is only used to detect noisy parts of the iris region and features extracted from there will be excluded in matching step. Whereas depending on the filter structure used in feature extraction, the noisy parts may influence relevant features. To the best of our knowledge, the effect of noise factors on feature extraction has not been considered in the previous works. This paper investigates the effect of shape adaptive wavelet transform and shape adaptive Gabor-wavelet for feature extraction on the iris recognition performance. In addition, an effective noise-removing approach is proposed in this paper. The contribution is to detect eyelashes and reflections by calculating appropriate thresholds by a procedure called statistical decision making. The eyelids are segmented by parabolic Hough transform in normalized iris image to decrease computational burden through omitting rotation term. The iris is localized by an accurate and fast algorithm based on coarse-to-fine strategy. The principle of mask code generation is to assign the noisy bits in an iris code in order to exclude them in matching step is presented in details. An experimental result shows that by using the shape adaptive Gabor-wavelet technique there is an improvement on the accuracy of recognition rate.

  19. A gallery approach for off-angle iris recognition

    NASA Astrophysics Data System (ADS)

    Karakaya, Mahmut; Yoldash, Rashiduddin; Boehnen, Christopher

    2015-05-01

    It has been proven that hamming distance score between frontal and off-angle iris images of same eye differs in iris recognition system. The distinction of hamming distance score is caused by many factors such as image acquisition angle, occlusion, pupil dilation, and limbus effect. In this paper, we first study the effect of the angle variations between iris plane and the image acquisition systems. We present how hamming distance changes for different off-angle iris images even if they are coming from the same iris. We observe that increment in acquisition angle of compared iris images causes the increment in hamming distance. Second, we propose a new technique in off-angle iris recognition system that includes creating a gallery of different off-angle iris images (such as, 0, 10, 20, 30, 40, and 50 degrees) and comparing each probe image with these gallery images. We will show the accuracy of the gallery approach for off-angle iris recognition.

  20. Noisy Ocular Recognition Based on Three Convolutional Neural Networks

    PubMed Central

    Lee, Min Beom; Hong, Hyung Gil; Park, Kang Ryoung

    2017-01-01

    In recent years, the iris recognition system has been gaining increasing acceptance for applications such as access control and smartphone security. When the images of the iris are obtained under unconstrained conditions, an issue of undermined quality is caused by optical and motion blur, off-angle view (the user’s eyes looking somewhere else, not into the front of the camera), specular reflection (SR) and other factors. Such noisy iris images increase intra-individual variations and, as a result, reduce the accuracy of iris recognition. A typical iris recognition system requires a near-infrared (NIR) illuminator along with an NIR camera, which are larger and more expensive than fingerprint recognition equipment. Hence, many studies have proposed methods of using iris images captured by a visible light camera without the need for an additional illuminator. In this research, we propose a new recognition method for noisy iris and ocular images by using one iris and two periocular regions, based on three convolutional neural networks (CNNs). Experiments were conducted by using the noisy iris challenge evaluation-part II (NICE.II) training dataset (selected from the university of Beira iris (UBIRIS).v2 database), mobile iris challenge evaluation (MICHE) database, and institute of automation of Chinese academy of sciences (CASIA)-Iris-Distance database. As a result, the method proposed by this study outperformed previous methods. PMID:29258217

  1. Iris Recognition Using Feature Extraction of Box Counting Fractal Dimension

    NASA Astrophysics Data System (ADS)

    Khotimah, C.; Juniati, D.

    2018-01-01

    Biometrics is a science that is now growing rapidly. Iris recognition is a biometric modality which captures a photo of the eye pattern. The markings of the iris are distinctive that it has been proposed to use as a means of identification, instead of fingerprints. Iris recognition was chosen for identification in this research because every human has a special feature that each individual is different and the iris is protected by the cornea so that it will have a fixed shape. This iris recognition consists of three step: pre-processing of data, feature extraction, and feature matching. Hough transformation is used in the process of pre-processing to locate the iris area and Daugman’s rubber sheet model to normalize the iris data set into rectangular blocks. To find the characteristics of the iris, it was used box counting method to get the fractal dimension value of the iris. Tests carried out by used k-fold cross method with k = 5. In each test used 10 different grade K of K-Nearest Neighbor (KNN). The result of iris recognition was obtained with the best accuracy was 92,63 % for K = 3 value on K-Nearest Neighbor (KNN) method.

  2. Computational cameras for moving iris recognition

    NASA Astrophysics Data System (ADS)

    McCloskey, Scott; Venkatesha, Sharath

    2015-05-01

    Iris-based biometric identification is increasingly used for facility access and other security applications. Like all methods that exploit visual information, however, iris systems are limited by the quality of captured images. Optical defocus due to a small depth of field (DOF) is one such challenge, as is the acquisition of sharply-focused iris images from subjects in motion. This manuscript describes the application of computational motion-deblurring cameras to the problem of moving iris capture, from the underlying theory to system considerations and performance data.

  3. Toward noncooperative iris recognition: a classification approach using multiple signatures.

    PubMed

    Proença, Hugo; Alexandre, Luís A

    2007-04-01

    This paper focuses on noncooperative iris recognition, i.e., the capture of iris images at large distances, under less controlled lighting conditions, and without active participation of the subjects. This increases the probability of capturing very heterogeneous images (regarding focus, contrast, or brightness) and with several noise factors (iris obstructions and reflections). Current iris recognition systems are unable to deal with noisy data and substantially increase their error rates, especially the false rejections, in these conditions. We propose an iris classification method that divides the segmented and normalized iris image into six regions, makes an independent feature extraction and comparison for each region, and combines each of the dissimilarity values through a classification rule. Experiments show a substantial decrease, higher than 40 percent, of the false rejection rates in the recognition of noisy iris images.

  4. Secondary iris recognition method based on local energy-orientation feature

    NASA Astrophysics Data System (ADS)

    Huo, Guang; Liu, Yuanning; Zhu, Xiaodong; Dong, Hongxing

    2015-01-01

    This paper proposes a secondary iris recognition based on local features. The application of the energy-orientation feature (EOF) by two-dimensional Gabor filter to the extraction of the iris goes before the first recognition by the threshold of similarity, which sets the whole iris database into two categories-a correctly recognized class and a class to be recognized. Therefore, the former are accepted and the latter are transformed by histogram to achieve an energy-orientation histogram feature (EOHF), which is followed by a second recognition with the chi-square distance. The experiment has proved that the proposed method, because of its higher correct recognition rate, could be designated as the most efficient and effective among its companion studies in iris recognition algorithms.

  5. Use of Biometrics within Sub-Saharan Refugee Communities

    DTIC Science & Technology

    2013-12-01

    fingerprint patterns, iris pattern recognition, and facial recognition as a means of establishing an individual’s identity. Biometrics creates and...Biometrics typically comprises fingerprint patterns, iris pattern recognition, and facial recognition as a means of establishing an individual’s identity...authentication because it identifies an individual based on mathematical analysis of the random pattern visible within the iris. Facial recognition is

  6. Comparison and evaluation of datasets for off-angle iris recognition

    NASA Astrophysics Data System (ADS)

    Kurtuncu, Osman M.; Cerme, Gamze N.; Karakaya, Mahmut

    2016-05-01

    In this paper, we investigated the publicly available iris recognition datasets and their data capture procedures in order to determine if they are suitable for the stand-off iris recognition research. Majority of the iris recognition datasets include only frontal iris images. Even if a few datasets include off-angle iris images, the frontal and off-angle iris images are not captured at the same time. The comparison of the frontal and off-angle iris images shows not only differences in the gaze angle but also change in pupil dilation and accommodation as well. In order to isolate the effect of the gaze angle from other challenging issues including dilation and accommodation, the frontal and off-angle iris images are supposed to be captured at the same time by using two different cameras. Therefore, we developed an iris image acquisition platform by using two cameras in this work where one camera captures frontal iris image and the other one captures iris images from off-angle. Based on the comparison of Hamming distance between frontal and off-angle iris images captured with the two-camera- setup and one-camera-setup, we observed that Hamming distance in two-camera-setup is less than one-camera-setup ranging from 0.05 to 0.001. These results show that in order to have accurate results in the off-angle iris recognition research, two-camera-setup is necessary in order to distinguish the challenging issues from each other.

  7. Test of the Practicality and Feasibility of EDoF-Empowered Image Sensors for Long-Range Biometrics.

    PubMed

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao

    2016-11-25

    For many practical applications of image sensors, how to extend the depth-of-field (DoF) is an important research topic; if successfully implemented, it could be beneficial in various applications, from photography to biometrics. In this work, we want to examine the feasibility and practicability of a well-known "extended DoF" (EDoF) technique, or "wavefront coding," by building real-time long-range iris recognition and performing large-scale iris recognition. The key to the success of long-range iris recognition includes long DoF and image quality invariance toward various object distance, which is strict and harsh enough to test the practicality and feasibility of EDoF-empowered image sensors. Besides image sensor modification, we also explored the possibility of varying enrollment/testing pairs. With 512 iris images from 32 Asian people as the database, 400-mm focal length and F/6.3 optics over 3 m working distance, our results prove that a sophisticated coding design scheme plus homogeneous enrollment/testing setups can effectively overcome the blurring caused by phase modulation and omit Wiener-based restoration. In our experiments, which are based on 3328 iris images in total, the EDoF factor can achieve a result 3.71 times better than the original system without a loss of recognition accuracy.

  8. Face-iris multimodal biometric scheme based on feature level fusion

    NASA Astrophysics Data System (ADS)

    Huo, Guang; Liu, Yuanning; Zhu, Xiaodong; Dong, Hongxing; He, Fei

    2015-11-01

    Unlike score level fusion, feature level fusion demands all the features extracted from unimodal traits with high distinguishability, as well as homogeneity and compatibility, which is difficult to achieve. Therefore, most multimodal biometric research focuses on score level fusion, whereas few investigate feature level fusion. We propose a face-iris recognition method based on feature level fusion. We build a special two-dimensional-Gabor filter bank to extract local texture features from face and iris images, and then transform them by histogram statistics into an energy-orientation variance histogram feature with lower dimensions and higher distinguishability. Finally, through a fusion-recognition strategy based on principal components analysis and support vector machine (FRSPS), feature level fusion and one-to-n identification are accomplished. The experimental results demonstrate that this method can not only effectively extract face and iris features but also provide higher recognition accuracy. Compared with some state-of-the-art fusion methods, the proposed method has a significant performance advantage.

  9. A new approach for cancelable iris recognition

    NASA Astrophysics Data System (ADS)

    Yang, Kai; Sui, Yan; Zhou, Zhi; Du, Yingzi; Zou, Xukai

    2010-04-01

    The iris is a stable and reliable biometric for positive human identification. However, the traditional iris recognition scheme raises several privacy concerns. One's iris pattern is permanently bound with him and cannot be changed. Hence, once it is stolen, this biometric is lost forever as well as all the applications where this biometric is used. Thus, new methods are desirable to secure the original pattern and ensure its revocability and alternatives when compromised. In this paper, we propose a novel scheme which incorporates iris features, non-invertible transformation and data encryption to achieve "cancelability" and at the same time increases iris recognition accuracy.

  10. Performance and Usage of Biometrics in a Testbed Environment for Tactical Purposes

    DTIC Science & Technology

    2006-12-01

    19 c. Facial Recognition ..................................................................20...geometry, iris recognition, and facial recognition (Layman’s, 2005). Behavioral biometrics can be described not as a physical characteristic, but are...are at: • Correction facilities • Department of Motor Vehicle • Military checkpoints • POW facilities c. Facial Recognition Facial recognition is

  11. Effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication.

    PubMed

    Dhir, L; Habib, N E; Monro, D M; Rakshit, S

    2010-06-01

    The purpose of this study was to investigate the effect of cataract surgery and pupil dilation on iris pattern recognition for personal authentication. Prospective non-comparative cohort study. Images of 15 subjects were captured before (enrolment), and 5, 10, and 15 min after instillation of mydriatics before routine cataract surgery. After cataract surgery, images were captured 2 weeks thereafter. Enrolled and test images (after pupillary dilation and after cataract surgery) were segmented to extract the iris. This was then unwrapped onto a rectangular format for normalization and a novel method using the Discrete Cosine Transform was applied to encode the image into binary bits. The numerical difference between two iris codes (Hamming distance, HD) was calculated. The HD between identification and enrolment codes was used as a score and was compared with a confidence threshold for specific equipment, giving a match or non-match result. The Correct Recognition Rate (CRR) and Equal Error Rates (EERs) were calculated to analyse overall system performance. After cataract surgery, perfect identification and verification was achieved, with zero false acceptance rate, zero false rejection rate, and zero EER. After pupillary dilation, non-elastic deformation occurs and a CRR of 86.67% and EER of 9.33% were obtained. Conventional circle-based localization methods are inadequate. Matching reliability decreases considerably with increase in pupillary dilation. Cataract surgery has no effect on iris pattern recognition, whereas pupil dilation may be used to defeat an iris-based authentication system.

  12. Comparing an FPGA to a Cell for an Image Processing Application

    NASA Astrophysics Data System (ADS)

    Rakvic, Ryan N.; Ngo, Hau; Broussard, Randy P.; Ives, Robert W.

    2010-12-01

    Modern advancements in configurable hardware, most notably Field-Programmable Gate Arrays (FPGAs), have provided an exciting opportunity to discover the parallel nature of modern image processing algorithms. On the other hand, PlayStation3 (PS3) game consoles contain a multicore heterogeneous processor known as the Cell, which is designed to perform complex image processing algorithms at a high performance. In this research project, our aim is to study the differences in performance of a modern image processing algorithm on these two hardware platforms. In particular, Iris Recognition Systems have recently become an attractive identification method because of their extremely high accuracy. Iris matching, a repeatedly executed portion of a modern iris recognition algorithm, is parallelized on an FPGA system and a Cell processor. We demonstrate a 2.5 times speedup of the parallelized algorithm on the FPGA system when compared to a Cell processor-based version.

  13. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    NASA Astrophysics Data System (ADS)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  14. Iris recognition via plenoptic imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J.; Boehnen, Chris Bensing; Bolme, David S.

    Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.

  15. Using crypts as iris minutiae

    NASA Astrophysics Data System (ADS)

    Shen, Feng; Flynn, Patrick J.

    2013-05-01

    Iris recognition is one of the most reliable biometric technologies for identity recognition and verification, but it has not been used in a forensic context because the representation and matching of iris features are not straightforward for traditional iris recognition techniques. In this paper we concentrate on the iris crypt as a visible feature used to represent the characteristics of irises in a similar way to fingerprint minutiae. The matching of crypts is based on their appearances and locations. The number of matching crypt pairs found between two irises can be used for identity verification and the convenience of manual inspection makes iris crypts a potential candidate for forensic applications.

  16. Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis.

    PubMed

    Prakash, Gaurav; Ashok Kumar, Dhivya; Agarwal, Amar; Jacob, Soosan; Sarvanan, Yoga; Agarwal, Athiya

    2010-02-01

    To analyze the predictive factors associated with success of iris recognition and dynamic rotational eye tracking on a laser in situ keratomileusis (LASIK) platform with active assessment and correction of intraoperative cyclotorsion. Interventional case series. Two hundred seventy-five eyes of 142 consecutive candidates underwent LASIK with attempted iris recognition and dynamic rotational tracking on the Technolas 217z100 platform (Techolas Perfect Vision, St Louis, Missouri, USA) at a tertiary care ophthalmic hospital. The main outcome measures were age, gender, flap creation method (femtosecond, microkeratome, epi-LASIK), success of static rotational tracking, ablation algorithm, pulses, and depth; preablation and intraablation rotational activity were analyzed and evaluated using regression models. Preablation static iris recognition was successful in 247 eyes, without difference in flap creation methods (P = .6). Age (partial correlation, -0.16; P = .014), amount of pulses (partial correlation, 0.39; P = 1.6 x 10(-8)), and gender (P = .02) were significant predictive factors for the amount of intraoperative cyclodeviation. Tracking difficulties leading to linking the ablation with a new intraoperatively acquired iris image were more with femtosecond-assisted flaps (P = 2.8 x 10(-7)) and the amount of intraoperative cyclotorsion (P = .02). However, the number of cases having nonresolvable failure of intraoperative rotational tracking was similar in the 3 flap creation methods (P = .22). Intraoperative cyclotorsional activity depends on the age, gender, and duration of ablation (pulses delivered). Femtosecond flaps do not seem to have a disadvantage over microkeratome flaps as far as iris recognition and success of intraoperative dynamic rotational tracking is concerned. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. Test of the Practicality and Feasibility of EDoF-Empowered Image Sensors for Long-Range Biometrics

    PubMed Central

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao

    2016-01-01

    For many practical applications of image sensors, how to extend the depth-of-field (DoF) is an important research topic; if successfully implemented, it could be beneficial in various applications, from photography to biometrics. In this work, we want to examine the feasibility and practicability of a well-known “extended DoF” (EDoF) technique, or “wavefront coding,” by building real-time long-range iris recognition and performing large-scale iris recognition. The key to the success of long-range iris recognition includes long DoF and image quality invariance toward various object distance, which is strict and harsh enough to test the practicality and feasibility of EDoF-empowered image sensors. Besides image sensor modification, we also explored the possibility of varying enrollment/testing pairs. With 512 iris images from 32 Asian people as the database, 400-mm focal length and F/6.3 optics over 3 m working distance, our results prove that a sophisticated coding design scheme plus homogeneous enrollment/testing setups can effectively overcome the blurring caused by phase modulation and omit Wiener-based restoration. In our experiments, which are based on 3328 iris images in total, the EDoF factor can achieve a result 3.71 times better than the original system without a loss of recognition accuracy. PMID:27897976

  18. Frontal view reconstruction for iris recognition

    DOEpatents

    Santos-Villalobos, Hector J; Bolme, David S; Boehnen, Chris Bensing

    2015-02-17

    Iris recognition can be accomplished for a wide variety of eye images by correcting input images with an off-angle gaze. A variety of techniques, from limbus modeling, corneal refraction modeling, optical flows, and genetic algorithms can be used. A variety of techniques, including aspherical eye modeling, corneal refraction modeling, ray tracing, and the like can be employed. Precomputed transforms can enhance performance for use in commercial applications. With application of the technologies, images with significantly unfavorable gaze angles can be successfully recognized.

  19. Does Iris Change Over Time?

    PubMed Central

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008–2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs. PMID:24244305

  20. Does iris change over time?

    PubMed

    Mehrotra, Hunny; Vatsa, Mayank; Singh, Richa; Majhi, Banshidhar

    2013-01-01

    Iris as a biometric identifier is assumed to be stable over a period of time. However, some researchers have observed that for long time lapse, the genuine match score distribution shifts towards the impostor score distribution and the performance of iris recognition reduces. The main purpose of this study is to determine if the shift in genuine scores can be attributed to aging or not. The experiments are performed on the two publicly available iris aging databases namely, ND-Iris-Template-Aging-2008-2010 and ND-TimeLapseIris-2012 using a commercial matcher, VeriEye. While existing results are correct about increase in false rejection over time, we observe that it is primarily due to the presence of other covariates such as blur, noise, occlusion, and pupil dilation. This claim is substantiated with quality score comparison of the gallery and probe pairs.

  1. A multi-approach feature extractions for iris recognition

    NASA Astrophysics Data System (ADS)

    Sanpachai, H.; Settapong, M.

    2014-04-01

    Biometrics is a promising technique that is used to identify individual traits and characteristics. Iris recognition is one of the most reliable biometric methods. As iris texture and color is fully developed within a year of birth, it remains unchanged throughout a person's life. Contrary to fingerprint, which can be altered due to several aspects including accidental damage, dry or oily skin and dust. Although iris recognition has been studied for more than a decade, there are limited commercial products available due to its arduous requirement such as camera resolution, hardware size, expensive equipment and computational complexity. However, at the present time, technology has overcome these obstacles. Iris recognition can be done through several sequential steps which include pre-processing, features extractions, post-processing, and matching stage. In this paper, we adopted the directional high-low pass filter for feature extraction. A box-counting fractal dimension and Iris code have been proposed as feature representations. Our approach has been tested on CASIA Iris Image database and the results are considered successful.

  2. A novel iris patterns matching algorithm of weighted polar frequency correlation

    NASA Astrophysics Data System (ADS)

    Zhao, Weijie; Jiang, Linhua

    2014-11-01

    Iris recognition is recognized as one of the most accurate techniques for biometric authentication. In this paper, we present a novel correlation method - Weighted Polar Frequency Correlation(WPFC) - to match and evaluate two iris images, actually it can also be used for evaluating the similarity of any two images. The WPFC method is a novel matching and evaluating method for iris image matching, which is complete different from the conventional methods. For instance, the classical John Daugman's method of iris recognition uses 2D Gabor wavelets to extract features of iris image into a compact bit stream, and then matching two bit streams with hamming distance. Our new method is based on the correlation in the polar coordinate system in frequency domain with regulated weights. The new method is motivated by the observation that the pattern of iris that contains far more information for recognition is fine structure at high frequency other than the gross shapes of iris images. Therefore, we transform iris images into frequency domain and set different weights to frequencies. Then calculate the correlation of two iris images in frequency domain. We evaluate the iris images by summing the discrete correlation values with regulated weights, comparing the value with preset threshold to tell whether these two iris images are captured from the same person or not. Experiments are carried out on both CASIA database and self-obtained images. The results show that our method is functional and reliable. Our method provides a new prospect for iris recognition system.

  3. Extending the Capture Volume of an Iris Recognition System Using Wavefront Coding and Super-Resolution.

    PubMed

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Tien, Chung-Hao; Chang, Chin-Chen

    2016-12-01

    Iris recognition has gained increasing popularity over the last few decades; however, the stand-off distance in a conventional iris recognition system is too short, which limits its application. In this paper, we propose a novel hardware-software hybrid method to increase the stand-off distance in an iris recognition system. When designing the system hardware, we use an optimized wavefront coding technique to extend the depth of field. To compensate for the blurring of the image caused by wavefront coding, on the software side, the proposed system uses a local patch-based super-resolution method to restore the blurred image to its clear version. The collaborative effect of the new hardware design and software post-processing showed great potential in our experiment. The experimental results showed that such improvement cannot be achieved by using a hardware-or software-only design. The proposed system can increase the capture volume of a conventional iris recognition system by three times and maintain the system's high recognition rate.

  4. Surface ablation with iris recognition and dynamic rotational eye tracking-based tissue saving treatment with the Technolas 217z excimer laser.

    PubMed

    Prakash, Gaurav; Agarwal, Amar; Kumar, Dhivya Ashok; Jacob, Soosan; Agarwal, Athiya; Maity, Amrita

    2011-03-01

    To evaluate the visual and refractive outcomes and expected benefits of Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking. This prospective, interventional case series comprised 122 eyes (70 patients). Pre- and postoperative assessment included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, and higher order aberrations. All patients underwent Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking using the Technolas 217z 100-Hz excimer platform (Technolas Perfect Vision GmbH). Follow-up was performed up to 6 months postoperatively. Theoretical benefit analysis was performed to evaluate the algorithm's outcomes compared to others. Preoperative spherocylindrical power was sphere -3.62 ± 1.60 diopters (D) (range: 0 to -6.75 D), cylinder -1.15 ± 1.00 D (range: 0 to -3.50 D), and spherical equivalent -4.19 ± 1.60 D (range: -7.75 to -2.00 D). At 6 months, 91% (111/122) of eyes were within ± 0.50 D of attempted correction. Postoperative UDVA was comparable to preoperative CDVA at 1 month (P=.47) and progressively improved at 6 months (P=.004). Two eyes lost one line of CDVA at 6 months. Theoretical benefit analysis revealed that of 101 eyes with astigmatism, 29 would have had cyclotorsion-induced astigmatism of ≥ 10% if iris recognition and dynamic rotational eye tracking were not used. Furthermore, the mean percentage decrease in maximum depth of ablation by using the Tissue Saving Treatment was 11.8 ± 2.9% over Aspheric, 17.8 ± 6.2% over Personalized, and 18.2 ± 2.8% over Planoscan algorithms. Tissue saving surface ablation with iris recognition and dynamic rotational eye tracking was safe and effective in this series of eyes. Copyright 2011, SLACK Incorporated.

  5. Performance Evaluation of Multimodal Multifeature Authentication System Using KNN Classification.

    PubMed

    Rajagopal, Gayathri; Palaniswamy, Ramamoorthy

    2015-01-01

    This research proposes a multimodal multifeature biometric system for human recognition using two traits, that is, palmprint and iris. The purpose of this research is to analyse integration of multimodal and multifeature biometric system using feature level fusion to achieve better performance. The main aim of the proposed system is to increase the recognition accuracy using feature level fusion. The features at the feature level fusion are raw biometric data which contains rich information when compared to decision and matching score level fusion. Hence information fused at the feature level is expected to obtain improved recognition accuracy. However, information fused at feature level has the problem of curse in dimensionality; here PCA (principal component analysis) is used to diminish the dimensionality of the feature sets as they are high dimensional. The proposed multimodal results were compared with other multimodal and monomodal approaches. Out of these comparisons, the multimodal multifeature palmprint iris fusion offers significant improvements in the accuracy of the suggested multimodal biometric system. The proposed algorithm is tested using created virtual multimodal database using UPOL iris database and PolyU palmprint database.

  6. Performance Evaluation of Multimodal Multifeature Authentication System Using KNN Classification

    PubMed Central

    Rajagopal, Gayathri; Palaniswamy, Ramamoorthy

    2015-01-01

    This research proposes a multimodal multifeature biometric system for human recognition using two traits, that is, palmprint and iris. The purpose of this research is to analyse integration of multimodal and multifeature biometric system using feature level fusion to achieve better performance. The main aim of the proposed system is to increase the recognition accuracy using feature level fusion. The features at the feature level fusion are raw biometric data which contains rich information when compared to decision and matching score level fusion. Hence information fused at the feature level is expected to obtain improved recognition accuracy. However, information fused at feature level has the problem of curse in dimensionality; here PCA (principal component analysis) is used to diminish the dimensionality of the feature sets as they are high dimensional. The proposed multimodal results were compared with other multimodal and monomodal approaches. Out of these comparisons, the multimodal multifeature palmprint iris fusion offers significant improvements in the accuracy of the suggested multimodal biometric system. The proposed algorithm is tested using created virtual multimodal database using UPOL iris database and PolyU palmprint database. PMID:26640813

  7. An Iris Segmentation Algorithm based on Edge Orientation for Off-angle Iris Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J

    Iris recognition is known as one of the most accurate and reliable biometrics. However, the accuracy of iris recognition systems depends on the quality of data capture and is negatively affected by several factors such as angle, occlusion, and dilation. In this paper, we present a segmentation algorithm for off-angle iris images that uses edge detection, edge elimination, edge classification, and ellipse fitting techniques. In our approach, we first detect all candidate edges in the iris image by using the canny edge detector; this collection contains edges from the iris and pupil boundaries as well as eyelash, eyelids, iris texturemore » etc. Edge orientation is used to eliminate the edges that cannot be part of the iris or pupil. Then, we classify the remaining edge points into two sets as pupil edges and iris edges. Finally, we randomly generate subsets of iris and pupil edge points, fit ellipses for each subset, select ellipses with similar parameters, and average to form the resultant ellipses. Based on the results from real experiments, the proposed method shows effectiveness in segmentation for off-angle iris images.« less

  8. Comparative study of multimodal biometric recognition by fusion of iris and fingerprint.

    PubMed

    Benaliouche, Houda; Touahria, Mohamed

    2014-01-01

    This research investigates the comparative performance from three different approaches for multimodal recognition of combined iris and fingerprints: classical sum rule, weighted sum rule, and fuzzy logic method. The scores from the different biometric traits of iris and fingerprint are fused at the matching score and the decision levels. The scores combination approach is used after normalization of both scores using the min-max rule. Our experimental results suggest that the fuzzy logic method for the matching scores combinations at the decision level is the best followed by the classical weighted sum rule and the classical sum rule in order. The performance evaluation of each method is reported in terms of matching time, error rates, and accuracy after doing exhaustive tests on the public CASIA-Iris databases V1 and V2 and the FVC 2004 fingerprint database. Experimental results prior to fusion and after fusion are presented followed by their comparison with related works in the current literature. The fusion by fuzzy logic decision mimics the human reasoning in a soft and simple way and gives enhanced results.

  9. Comparative Study of Multimodal Biometric Recognition by Fusion of Iris and Fingerprint

    PubMed Central

    Benaliouche, Houda; Touahria, Mohamed

    2014-01-01

    This research investigates the comparative performance from three different approaches for multimodal recognition of combined iris and fingerprints: classical sum rule, weighted sum rule, and fuzzy logic method. The scores from the different biometric traits of iris and fingerprint are fused at the matching score and the decision levels. The scores combination approach is used after normalization of both scores using the min-max rule. Our experimental results suggest that the fuzzy logic method for the matching scores combinations at the decision level is the best followed by the classical weighted sum rule and the classical sum rule in order. The performance evaluation of each method is reported in terms of matching time, error rates, and accuracy after doing exhaustive tests on the public CASIA-Iris databases V1 and V2 and the FVC 2004 fingerprint database. Experimental results prior to fusion and after fusion are presented followed by their comparison with related works in the current literature. The fusion by fuzzy logic decision mimics the human reasoning in a soft and simple way and gives enhanced results. PMID:24605065

  10. Ordinal measures for iris recognition.

    PubMed

    Sun, Zhenan; Tan, Tieniu

    2009-12-01

    Images of a human iris contain rich texture information useful for identity authentication. A key and still open issue in iris recognition is how best to represent such textural information using a compact set of features (iris features). In this paper, we propose using ordinal measures for iris feature representation with the objective of characterizing qualitative relationships between iris regions rather than precise measurements of iris image structures. Such a representation may lose some image-specific information, but it achieves a good trade-off between distinctiveness and robustness. We show that ordinal measures are intrinsic features of iris patterns and largely invariant to illumination changes. Moreover, compactness and low computational complexity of ordinal measures enable highly efficient iris recognition. Ordinal measures are a general concept useful for image analysis and many variants can be derived for ordinal feature extraction. In this paper, we develop multilobe differential filters to compute ordinal measures with flexible intralobe and interlobe parameters such as location, scale, orientation, and distance. Experimental results on three public iris image databases demonstrate the effectiveness of the proposed ordinal feature models.

  11. Multiple local feature representations and their fusion based on an SVR model for iris recognition using optimized Gabor filters

    NASA Astrophysics Data System (ADS)

    He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Dong, Hongxing

    2014-12-01

    Gabor descriptors have been widely used in iris texture representations. However, fixed basic Gabor functions cannot match the changing nature of diverse iris datasets. Furthermore, a single form of iris feature cannot overcome difficulties in iris recognition, such as illumination variations, environmental conditions, and device variations. This paper provides multiple local feature representations and their fusion scheme based on a support vector regression (SVR) model for iris recognition using optimized Gabor filters. In our iris system, a particle swarm optimization (PSO)- and a Boolean particle swarm optimization (BPSO)-based algorithm is proposed to provide suitable Gabor filters for each involved test dataset without predefinition or manual modulation. Several comparative experiments on JLUBR-IRIS, CASIA-I, and CASIA-V4-Interval iris datasets are conducted, and the results show that our work can generate improved local Gabor features by using optimized Gabor filters for each dataset. In addition, our SVR fusion strategy may make full use of their discriminative ability to improve accuracy and reliability. Other comparative experiments show that our approach may outperform other popular iris systems.

  12. Rapid Word Recognition as a Measure of Word-Level Automaticity and Its Relation to Other Measures of Reading

    ERIC Educational Resources Information Center

    Frye, Elizabeth M.; Gosky, Ross

    2012-01-01

    The present study investigated the relationship between rapid recognition of individual words (Word Recognition Test) and two measures of contextual reading: (1) grade-level Passage Reading Test (IRI passage) and (2) performance on standardized STAR Reading Test. To establish if time of presentation on the word recognition test was a factor in…

  13. The UBIRIS.v2: a database of visible wavelength iris images captured on-the-move and at-a-distance.

    PubMed

    Proença, Hugo; Filipe, Sílvio; Santos, Ricardo; Oliveira, João; Alexandre, Luís A

    2010-08-01

    The iris is regarded as one of the most useful traits for biometric recognition and the dissemination of nationwide iris-based recognition systems is imminent. However, currently deployed systems rely on heavy imaging constraints to capture near infrared images with enough quality. Also, all of the publicly available iris image databases contain data correspondent to such imaging constraints and therefore are exclusively suitable to evaluate methods thought to operate on these type of environments. The main purpose of this paper is to announce the availability of the UBIRIS.v2 database, a multisession iris images database which singularly contains data captured in the visible wavelength, at-a-distance (between four and eight meters) and on on-the-move. This database is freely available for researchers concerned about visible wavelength iris recognition and will be useful in accessing the feasibility and specifying the constraints of this type of biometric recognition.

  14. Feature Vector Construction Method for IRIS Recognition

    NASA Astrophysics Data System (ADS)

    Odinokikh, G.; Fartukov, A.; Korobkin, M.; Yoo, J.

    2017-05-01

    One of the basic stages of iris recognition pipeline is iris feature vector construction procedure. The procedure represents the extraction of iris texture information relevant to its subsequent comparison. Thorough investigation of feature vectors obtained from iris showed that not all the vector elements are equally relevant. There are two characteristics which determine the vector element utility: fragility and discriminability. Conventional iris feature extraction methods consider the concept of fragility as the feature vector instability without respect to the nature of such instability appearance. This work separates sources of the instability into natural and encodinginduced which helps deeply investigate each source of instability independently. According to the separation concept, a novel approach of iris feature vector construction is proposed. The approach consists of two steps: iris feature extraction using Gabor filtering with optimal parameters and quantization with separated preliminary optimized fragility thresholds. The proposed method has been tested on two different datasets of iris images captured under changing environmental conditions. The testing results show that the proposed method surpasses all the methods considered as a prior art by recognition accuracy on both datasets.

  15. Measuring Reading Performance Informally.

    ERIC Educational Resources Information Center

    Powell, William R.

    To improve the accuracy of the informal reading inventory (IRI), a differential set of criteria is necessary for both word recognition and comprehension scores for different levels and reading conditions. In initial evaluation, word recognition scores should reflect only errors of insertions, omissions, mispronunciations, substitiutions, unkown…

  16. An iris recognition algorithm based on DCT and GLCM

    NASA Astrophysics Data System (ADS)

    Feng, G.; Wu, Ye-qing

    2008-04-01

    With the enlargement of mankind's activity range, the significance for person's status identity is becoming more and more important. So many different techniques for person's status identity were proposed for this practical usage. Conventional person's status identity methods like password and identification card are not always reliable. A wide variety of biometrics has been developed for this challenge. Among those biologic characteristics, iris pattern gains increasing attention for its stability, reliability, uniqueness, noninvasiveness and difficult to counterfeit. The distinct merits of the iris lead to its high reliability for personal identification. So the iris identification technique had become hot research point in the past several years. This paper presents an efficient algorithm for iris recognition using gray-level co-occurrence matrix(GLCM) and Discrete Cosine transform(DCT). To obtain more representative iris features, features from space and DCT transformation domain are extracted. Both GLCM and DCT are applied on the iris image to form the feature sequence in this paper. The combination of GLCM and DCT makes the iris feature more distinct. Upon GLCM and DCT the eigenvector of iris extracted, which reflects features of spatial transformation and frequency transformation. Experimental results show that the algorithm is effective and feasible with iris recognition.

  17. Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karakaya, Mahmut; Barstow, Del R; Santos-Villalobos, Hector J

    Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction frommore » elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.« less

  18. DCT-based iris recognition.

    PubMed

    Monro, Donald M; Rakshit, Soumyadip; Zhang, Dexin

    2007-04-01

    This paper presents a novel iris coding method based on differences of discrete cosine transform (DCT) coefficients of overlapped angular patches from normalized iris images. The feature extraction capabilities of the DCT are optimized on the two largest publicly available iris image data sets, 2,156 images of 308 eyes from the CASIA database and 2,955 images of 150 eyes from the Bath database. On this data, we achieve 100 percent Correct Recognition Rate (CRR) and perfect Receiver-Operating Characteristic (ROC) Curves with no registered false accepts or rejects. Individual feature bit and patch position parameters are optimized for matching through a product-of-sum approach to Hamming distance calculation. For verification, a variable threshold is applied to the distance metric and the False Acceptance Rate (FAR) and False Rejection Rate (FRR) are recorded. A new worst-case metric is proposed for predicting practical system performance in the absence of matching failures, and the worst case theoretical Equal Error Rate (EER) is predicted to be as low as 2.59 x 10(-4) on the available data sets.

  19. Effects of Iris Surface Curvature on Iris Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Joseph T; Flynn, Patrick J; Bowyer, Kevin W

    To focus on objects at various distances, the lens of the eye must change shape to adjust its refractive power. This change in lens shape causes a change in the shape of the iris surface which can be measured by examining the curvature of the iris. This work isolates the variable of iris curvature in the recognition process and shows that differences in iris curvature degrade matching ability. To our knowledge, no other work has examined the effects of varying iris curvature on matching ability. To examine this degradation, we conduct a matching experiment across pairs of images with varyingmore » degrees of iris curvature differences. The results show a statistically signi cant degradation in matching ability. Finally, the real world impact of these ndings is discussed« less

  20. Off-Angle Iris Correction Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santos-Villalobos, Hector J; Thompson, Joseph T; Karakaya, Mahmut

    In many real world iris recognition systems obtaining consistent frontal images is problematic do to inexperienced or uncooperative users, untrained operators, or distracting environments. As a result many collected images are unusable by modern iris matchers. In this chapter we present four methods for correcting off-angle iris images to appear frontal which makes them compatible with existing iris matchers. The methods include an affine correction, a retraced model of the human eye, measured displacements, and a genetic algorithm optimized correction. The affine correction represents a simple way to create an iris image that appears frontal but it does not accountmore » for refractive distortions of the cornea. The other method account for refraction. The retraced model simulates the optical properties of the cornea. The other two methods are data driven. The first uses optical flow to measure the displacements of the iris texture when compared to frontal images of the same subject. The second uses a genetic algorithm to learn a mapping that optimizes the Hamming Distance scores between off-angle and frontal images. In this paper we hypothesize that the biological model presented in our earlier work does not adequately account for all variations in eye anatomy and therefore the two data-driven approaches should yield better performance. Results are presented using the commercial VeriEye matcher that show that the genetic algorithm method clearly improves over prior work and makes iris recognition possible up to 50 degrees off-angle.« less

  1. NATIONAL PREPAREDNESS: Integrating New and Existing Technology and Information Sharing into an Effective Homeland Security Strategy

    DTIC Science & Technology

    2002-06-07

    Continue to Develop and Refine Emerging Technology • Some of the emerging biometric devices, such as iris scans and facial recognition systems...such as iris scans and facial recognition systems, facial recognition systems, and speaker verification systems. (976301)

  2. Extending the imaging volume for biometric iris recognition.

    PubMed

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  3. Reducing Error Rates for Iris Image using higher Contrast in Normalization process

    NASA Astrophysics Data System (ADS)

    Aminu Ghali, Abdulrahman; Jamel, Sapiee; Abubakar Pindar, Zahraddeen; Hasssan Disina, Abdulkadir; Mat Daris, Mustafa

    2017-08-01

    Iris recognition system is the most secured, and faster means of identification and authentication. However, iris recognition system suffers a setback from blurring, low contrast and illumination due to low quality image which compromises the accuracy of the system. The acceptance or rejection rates of verified user depend solely on the quality of the image. In many cases, iris recognition system with low image contrast could falsely accept or reject user. Therefore this paper adopts Histogram Equalization Technique to address the problem of False Rejection Rate (FRR) and False Acceptance Rate (FAR) by enhancing the contrast of the iris image. A histogram equalization technique enhances the image quality and neutralizes the low contrast of the image at normalization stage. The experimental result shows that Histogram Equalization Technique has reduced FRR and FAR compared to the existing techniques.

  4. Extended depth of field system for long distance iris acquisition

    NASA Astrophysics Data System (ADS)

    Chen, Yuan-Lin; Hsieh, Sheng-Hsun; Hung, Kuo-En; Yang, Shi-Wen; Li, Yung-Hui; Tien, Chung-Hao

    2012-10-01

    Using biometric signatures for identity recognition has been practiced for centuries. Recently, iris recognition system attracts much attention due to its high accuracy and high stability. The texture feature of iris provides a signature that is unique for each subject. Currently most commercial iris recognition systems acquire images in less than 50 cm, which is a serious constraint that needs to be broken if we want to use it for airport access or entrance that requires high turn-over rate . In order to capture the iris patterns from a distance, in this study, we developed a telephoto imaging system with image processing techniques. By using the cubic phase mask positioned front of the camera, the point spread function was kept constant over a wide range of defocus. With adequate decoding filter, the blurred image was restored, where the working distance between the subject and the camera can be achieved over 3m associated with 500mm focal length and aperture F/6.3. The simulation and experimental results validated the proposed scheme, where the depth of focus of iris camera was triply extended over the traditional optics, while keeping sufficient recognition accuracy.

  5. Efficient Iris Recognition Based on Optimal Subfeature Selection and Weighted Subregion Fusion

    PubMed Central

    Deng, Ning

    2014-01-01

    In this paper, we propose three discriminative feature selection strategies and weighted subregion matching method to improve the performance of iris recognition system. Firstly, we introduce the process of feature extraction and representation based on scale invariant feature transformation (SIFT) in detail. Secondly, three strategies are described, which are orientation probability distribution function (OPDF) based strategy to delete some redundant feature keypoints, magnitude probability distribution function (MPDF) based strategy to reduce dimensionality of feature element, and compounded strategy combined OPDF and MPDF to further select optimal subfeature. Thirdly, to make matching more effective, this paper proposes a novel matching method based on weighted sub-region matching fusion. Particle swarm optimization is utilized to accelerate achieve different sub-region's weights and then weighted different subregions' matching scores to generate the final decision. The experimental results, on three public and renowned iris databases (CASIA-V3 Interval, Lamp, andMMU-V1), demonstrate that our proposed methods outperform some of the existing methods in terms of correct recognition rate, equal error rate, and computation complexity. PMID:24683317

  6. Efficient iris recognition based on optimal subfeature selection and weighted subregion fusion.

    PubMed

    Chen, Ying; Liu, Yuanning; Zhu, Xiaodong; He, Fei; Wang, Hongye; Deng, Ning

    2014-01-01

    In this paper, we propose three discriminative feature selection strategies and weighted subregion matching method to improve the performance of iris recognition system. Firstly, we introduce the process of feature extraction and representation based on scale invariant feature transformation (SIFT) in detail. Secondly, three strategies are described, which are orientation probability distribution function (OPDF) based strategy to delete some redundant feature keypoints, magnitude probability distribution function (MPDF) based strategy to reduce dimensionality of feature element, and compounded strategy combined OPDF and MPDF to further select optimal subfeature. Thirdly, to make matching more effective, this paper proposes a novel matching method based on weighted sub-region matching fusion. Particle swarm optimization is utilized to accelerate achieve different sub-region's weights and then weighted different subregions' matching scores to generate the final decision. The experimental results, on three public and renowned iris databases (CASIA-V3 Interval, Lamp, and MMU-V1), demonstrate that our proposed methods outperform some of the existing methods in terms of correct recognition rate, equal error rate, and computation complexity.

  7. Iris Image Classification Based on Hierarchical Visual Codebook.

    PubMed

    Zhenan Sun; Hui Zhang; Tieniu Tan; Jianyu Wang

    2014-06-01

    Iris recognition as a reliable method for personal identification has been well-studied with the objective to assign the class label of each iris image to a unique subject. In contrast, iris image classification aims to classify an iris image to an application specific category, e.g., iris liveness detection (classification of genuine and fake iris images), race classification (e.g., classification of iris images of Asian and non-Asian subjects), coarse-to-fine iris identification (classification of all iris images in the central database into multiple categories). This paper proposes a general framework for iris image classification based on texture analysis. A novel texture pattern representation method called Hierarchical Visual Codebook (HVC) is proposed to encode the texture primitives of iris images. The proposed HVC method is an integration of two existing Bag-of-Words models, namely Vocabulary Tree (VT), and Locality-constrained Linear Coding (LLC). The HVC adopts a coarse-to-fine visual coding strategy and takes advantages of both VT and LLC for accurate and sparse representation of iris texture. Extensive experimental results demonstrate that the proposed iris image classification method achieves state-of-the-art performance for iris liveness detection, race classification, and coarse-to-fine iris identification. A comprehensive fake iris image database simulating four types of iris spoof attacks is developed as the benchmark for research of iris liveness detection.

  8. Edge detection techniques for iris recognition system

    NASA Astrophysics Data System (ADS)

    Tania, U. T.; Motakabber, S. M. A.; Ibrahimy, M. I.

    2013-12-01

    Nowadays security and authentication are the major parts of our daily life. Iris is one of the most reliable organ or part of human body which can be used for identification and authentication purpose. To develop an iris authentication algorithm for personal identification, this paper examines two edge detection techniques for iris recognition system. Between the Sobel and the Canny edge detection techniques, the experimental result shows that the Canny's technique has better ability to detect points in a digital image where image gray level changes even at slow rate.

  9. Iris recognition and what is next? Iris diagnosis: a new challenging topic for machine vision from image acquisition to image interpretation

    NASA Astrophysics Data System (ADS)

    Perner, Petra

    2017-03-01

    Molecular image-based techniques are widely used in medicine to detect specific diseases. Look diagnosis is an important issue but also the analysis of the eye plays an important role in order to detect specific diseases. These topics are important topics in medicine and the standardization of these topics by an automatic system can be a new challenging field for machine vision. Compared to iris recognition has the iris diagnosis much more higher demands for the image acquisition and interpretation of the iris. One understands by iris diagnosis (Iridology) the investigation and analysis of the colored part of the eye, the iris, to discover factors, which play an important role for the prevention and treatment of illnesses, but also for the preservation of an optimum health. An automatic system would pave the way for a much wider use of the iris diagnosis for the diagnosis of illnesses and for the purpose of individual health protection. With this paper, we describe our work towards an automatic iris diagnosis system. We describe the image acquisition and the problems with it. Different ways are explained for image acquisition and image preprocessing. We describe the image analysis method for the detection of the iris. The meta-model for image interpretation is given. Based on this model we show the many tasks for image analysis that range from different image-object feature analysis, spatial image analysis to color image analysis. Our first results for the recognition of the iris are given. We describe how detecting the pupil and not wanted lamp spots. We explain how to recognize orange blue spots in the iris and match them against the topological map of the iris. Finally, we give an outlook for further work.

  10. A field study of the accuracy and reliability of a biometric iris recognition system.

    PubMed

    Latman, Neal S; Herb, Emily

    2013-06-01

    The iris of the eye appears to satisfy the criteria for a good anatomical characteristic for use in a biometric system. The purpose of this study was to evaluate a biometric iris recognition system: Mobile-Eyes™. The enrollment, verification, and identification applications were evaluated in a field study for accuracy and reliability using both irises of 277 subjects. Independent variables included a wide range of subject demographics, ambient light, and ambient temperature. A sub-set of 35 subjects had alcohol-induced nystagmus. There were 2710 identification and verification attempts, which resulted in 1,501,340 and 5540 iris comparisons respectively. In this study, the system successfully enrolled all subjects on the first attempt. All 277 subjects were successfully verified and identified on the first day of enrollment. None of the current or prior eye conditions prevented enrollment, verification, or identification. All 35 subjects with alcohol-induced nystagmus were successfully verified and identified. There were no false verifications or false identifications. Two conditions were identified that potentially could circumvent the use of iris recognitions systems in general. The Mobile-Eyes™ iris recognition system exhibited accurate and reliable enrollment, verification, and identification applications in this study. It may have special applications in subjects with nystagmus. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  11. New methods in iris recognition.

    PubMed

    Daugman, John

    2007-10-01

    This paper presents the following four advances in iris recognition: 1) more disciplined methods for detecting and faithfully modeling the iris inner and outer boundaries with active contours, leading to more flexible embedded coordinate systems; 2) Fourier-based methods for solving problems in iris trigonometry and projective geometry, allowing off-axis gaze to be handled by detecting it and "rotating" the eye into orthographic perspective; 3) statistical inference methods for detecting and excluding eyelashes; and 4) exploration of score normalizations, depending on the amount of iris data that is available in images and the required scale of database search. Statistical results are presented based on 200 billion iris cross-comparisons that were generated from 632500 irises in the United Arab Emirates database to analyze the normalization issues raised in different regions of receiver operating characteristic curves.

  12. Iris Cryptography for Security Purpose

    NASA Astrophysics Data System (ADS)

    Ajith, Srighakollapu; Balaji Ganesh Kumar, M.; Latha, S.; Samiappan, Dhanalakshmi; Muthu, P.

    2018-04-01

    In today's world, the security became the major issue to every human being. A major issue is hacking as hackers are everywhere, as the technology was developed still there are many issues where the technology fails to meet the security. Engineers, scientists were discovering the new products for security purpose as biometrics sensors like face recognition, pattern recognition, gesture recognition, voice authentication etcetera. But these devices fail to reach the expected results. In this work, we are going to present an approach to generate a unique secure key using the iris template. Here the iris templates are processed using the well-defined processing techniques. Using the encryption and decryption process they are stored, traversed and utilized. As of the work, we can conclude that the iris cryptography gives us the expected results for securing the data from eavesdroppers.

  13. Wavelet Types Comparison for Extracting Iris Feature Based on Energy Compaction

    NASA Astrophysics Data System (ADS)

    Rizal Isnanto, R.

    2015-06-01

    Human iris has a very unique pattern which is possible to be used as a biometric recognition. To identify texture in an image, texture analysis method can be used. One of method is wavelet that extract the image feature based on energy. Wavelet transforms used are Haar, Daubechies, Coiflets, Symlets, and Biorthogonal. In the research, iris recognition based on five mentioned wavelets was done and then comparison analysis was conducted for which some conclusions taken. Some steps have to be done in the research. First, the iris image is segmented from eye image then enhanced with histogram equalization. The features obtained is energy value. The next step is recognition using normalized Euclidean distance. Comparison analysis is done based on recognition rate percentage with two samples stored in database for reference images. After finding the recognition rate, some tests are conducted using Energy Compaction for all five types of wavelets above. As the result, the highest recognition rate is achieved using Haar, whereas for coefficients cutting for C(i) < 0.1, Haar wavelet has a highest percentage, therefore the retention rate or significan coefficient retained for Haaris lower than other wavelet types (db5, coif3, sym4, and bior2.4)

  14. Deep learning architecture for iris recognition based on optimal Gabor filters and deep belief network

    NASA Astrophysics Data System (ADS)

    He, Fei; Han, Ye; Wang, Han; Ji, Jinchao; Liu, Yuanning; Ma, Zhiqiang

    2017-03-01

    Gabor filters are widely utilized to detect iris texture information in several state-of-the-art iris recognition systems. However, the proper Gabor kernels and the generative pattern of iris Gabor features need to be predetermined in application. The traditional empirical Gabor filters and shallow iris encoding ways are incapable of dealing with such complex variations in iris imaging including illumination, aging, deformation, and device variations. Thereby, an adaptive Gabor filter selection strategy and deep learning architecture are presented. We first employ particle swarm optimization approach and its binary version to define a set of data-driven Gabor kernels for fitting the most informative filtering bands, and then capture complex pattern from the optimal Gabor filtered coefficients by a trained deep belief network. A succession of comparative experiments validate that our optimal Gabor filters may produce more distinctive Gabor coefficients and our iris deep representations be more robust and stable than traditional iris Gabor codes. Furthermore, the depth and scales of the deep learning architecture are also discussed.

  15. [Cyclorotation of the eye in wavefront-guided LASIK using a static eyetracker with iris recognition].

    PubMed

    Kohnen, T; Kühne, C; Cichocki, M; Strenger, A

    2007-01-01

    Centration of the ablation zone decisively influences the result of wavefront-guided LASIK. Cyclorotation of the eye occurs as the patient changes from the sitting position during aberrometry to the supine position during laser surgery and may lead to induction of lower and higher order aberrations. Twenty patients (40 eyes) underwent wavefront-guided LASIK (B&L 217z 100 excimer laser) with a static eyetracker driven by iris recognition (mean preoperative SE: -4.72+/-1.45 D; range: -1.63 to -7.00 D). The iris patterns of the patients' eyes were memorized during aberrometry and after flap creation. The mean absolute value of the measured cyclorotation was -1.5+/-4.2 degrees (range: -11.0 to 6.9 degrees ). The mean cyclorotation was 3.5+/-2.7 masculine (range: 0.1 to 11.0 degrees ). In 65% of all eyes cyclorotation was >2 masculine. A static eyetracker driven by iris recognition demonstrated that cyclorotation of up to 11 degrees may occur in myopic and myopic astigmatic eyes when changing from a sitting to a supine position. Use of static eyetrackers with iris recognition may provide a more precise positioning of the ablation profile as they detect and compensate cyclorotation.

  16. [Clinical analysis of real-time iris recognition guided LASIK with femtosecond laser flap creation for myopic astigmatism].

    PubMed

    Jie, Li-ming; Wang, Qian; Zheng, Lin

    2013-08-01

    To assess the safety, efficacy, stability and changes in cylindrical degree and axis after real-time iris recognition guided LASIK with femtosecond laser flap creation for the correction of myopic astigmatism. Retrospective case series. This observational case study comprised 136 patients (249 eyes) with myopic astigmatism in a 6-month trial. Patients were divided into 3 groups according to the pre-operative cylindrical degree: Group 1, -0.75 to -1.25 D, 106 eyes;Group 2, -1.50 to -2.25 D, 89 eyes and Group 3, -2.50 to -5.00 D, 54 eyes. They were also grouped by pre-operative astigmatism axis:Group A, with the rule astigmatism (WTRA), 156 eyes; Group B, against the rule astigmatism (ATRA), 64 eyes;Group C, oblique axis astigmatism, 29 eyes. After femtosecond laser flap created, real-time iris recognized excimer ablation was performed. The naked visual acuity, the best-corrected visual acuity, the degree and axis of astigmatism were analyzed and compared at 1, 3 and 6 months postoperatively. Static iris recognition detected that eye cyclotorsional misalignment was 2.37° ± 2.16°, dynamic iris recognition detected that the intraoperative cyclotorsional misalignment range was 0-4.3°. Six months after operation, the naked visual acuity was 0.5 or better in 100% cases. No eye lost ≥ 1 line of best spectacle-corrected visual acuity (BSCVA). Six months after operation, the naked vision of 227 eyes surpassed the BSCVA, and 87 eyes gained 1 line of BSCVA. The degree of astigmatism decreased from (-1.72 ± 0.77) D (pre-operation) to (-0.29 ± 0.25) D (post-operation). Six months after operation, WTRA from 157 eyes (pre-operation) decreased to 43 eyes (post-operation), ATRA from 63 eyes (pre-operation) decreased to 28 eyes (post-operation), oblique astigmatism increased from 29 eyes to 34 eyes and 144 eyes became non-astigmatism. The real-time iris recognition guided LASIK with femtosecond laser flap creation can compensate deviation from eye cyclotorsion, decrease iatrogenic astigmatism, and provides more precise treatment for the degree and axis of astigmatism .It is an effective and safe procedure for the treatment of myopic astigmatism.

  17. Modeling IrisCode and its variants as convex polyhedral cones and its security implications.

    PubMed

    Kong, Adams Wai-Kin

    2013-03-01

    IrisCode, developed by Daugman, in 1993, is the most influential iris recognition algorithm. A thorough understanding of IrisCode is essential, because over 100 million persons have been enrolled by this algorithm and many biometric personal identification and template protection methods have been developed based on IrisCode. This paper indicates that a template produced by IrisCode or its variants is a convex polyhedral cone in a hyperspace. Its central ray, being a rough representation of the original biometric signal, can be computed by a simple algorithm, which can often be implemented in one Matlab command line. The central ray is an expected ray and also an optimal ray of an objective function on a group of distributions. This algorithm is derived from geometric properties of a convex polyhedral cone but does not rely on any prior knowledge (e.g., iris images). The experimental results show that biometric templates, including iris and palmprint templates, produced by different recognition methods can be matched through the central rays in their convex polyhedral cones and that templates protected by a method extended from IrisCode can be broken into. These experimental results indicate that, without a thorough security analysis, convex polyhedral cone templates cannot be assumed secure. Additionally, the simplicity of the algorithm implies that even junior hackers without knowledge of advanced image processing and biometric databases can still break into protected templates and reveal relationships among templates produced by different recognition methods.

  18. Technical issues for the eye image database creation at distance

    NASA Astrophysics Data System (ADS)

    Oropesa Morales, Lester Arturo; Maldonado Cano, Luis Alejandro; Soto Aldaco, Andrea; García Vázquez, Mireya Saraí; Zamudio Fuentes, Luis Miguel; Rodríguez Vázquez, Manuel Antonio; Pérez Rosas, Osvaldo Gerardo; Rodríguez Espejo, Luis; Montoya Obeso, Abraham; Ramírez Acosta, Alejandro Álvaro

    2016-09-01

    Biometrics refers to identify people through their physical characteristics or behavior such as fingerprints, face, DNA, hand geometries, retina and iris patterns. Typically, the iris pattern is to acquire in short distance to recognize a person, however, in the past few years is a challenge identify a person by its iris pattern at certain distance in non-cooperative environments. This challenge comprises: 1) high quality iris image, 2) light variation, 3) blur reduction, 4) specular reflections reduction, 5) the distance from the acquisition system to the user, and 6) standardize the iris size and the density pixel of iris texture. The solution of the challenge will add robustness and enhance the iris recognition rates. For this reason, we describe the technical issues that must be considered during iris acquisition. Some of these considerations are the camera sensor, lens, the math analysis of depth of field (DOF) and field of view (FOV) for iris recognition. Finally, based on this issues we present experiment that show the result of captures obtained with our camera at distance and captures obtained with cameras in very short distance.

  19. Iris recognition using possibilistic fuzzy matching on local features.

    PubMed

    Tsai, Chung-Chih; Lin, Heng-Yi; Taur, Jinshiuh; Tao, Chin-Wang

    2012-02-01

    In this paper, we propose a novel possibilistic fuzzy matching strategy with invariant properties, which can provide a robust and effective matching scheme for two sets of iris feature points. In addition, the nonlinear normalization model is adopted to provide more accurate position before matching. Moreover, an effective iris segmentation method is proposed to refine the detected inner and outer boundaries to smooth curves. For feature extraction, the Gabor filters are adopted to detect the local feature points from the segmented iris image in the Cartesian coordinate system and to generate a rotation-invariant descriptor for each detected point. After that, the proposed matching algorithm is used to compute a similarity score for two sets of feature points from a pair of iris images. The experimental results show that the performance of our system is better than those of the systems based on the local features and is comparable to those of the typical systems.

  20. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors

    PubMed Central

    Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung

    2015-01-01

    Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands. PMID:26184214

  1. Nonintrusive Finger-Vein Recognition System Using NIR Image Sensor and Accuracy Analyses According to Various Factors.

    PubMed

    Pham, Tuyen Danh; Park, Young Ho; Nguyen, Dat Tien; Kwon, Seung Yong; Park, Kang Ryoung

    2015-07-13

    Biometrics is a technology that enables an individual person to be identified based on human physiological and behavioral characteristics. Among biometrics technologies, face recognition has been widely used because of its advantages in terms of convenience and non-contact operation. However, its performance is affected by factors such as variation in the illumination, facial expression, and head pose. Therefore, fingerprint and iris recognitions are preferred alternatives. However, the performance of the former can be adversely affected by the skin condition, including scarring and dryness. In addition, the latter has the disadvantages of high cost, large system size, and inconvenience to the user, who has to align their eyes with the iris camera. In an attempt to overcome these problems, finger-vein recognition has been vigorously researched, but an analysis of its accuracies according to various factors has not received much attention. Therefore, we propose a nonintrusive finger-vein recognition system using a near infrared (NIR) image sensor and analyze its accuracies considering various factors. The experimental results obtained with three databases showed that our system can be operated in real applications with high accuracy; and the dissimilarity of the finger-veins of different people is larger than that of the finger types and hands.

  2. Real-time image-guided nasogastric feeding tube placement: A case series using Kangaroo with IRIS Technology in an ICU.

    PubMed

    Mizzi, Anna; Cozzi, Silvano; Beretta, Luigi; Greco, Massimiliano; Braga, Marco

    2017-05-01

    Pulmonary misplacement during the blind insertion of enteral feeding tubes is frequent, particularly in ventilated and neurologically impaired patients. This is probably the first clinical study using the Kangaroo Feeding Tube with IRIS technology (IRIS) which incorporates a camera designed to provide anatomic landmark visualization during insertion. The study aim was to evaluate IRIS performance during bedside gastric placement. This is the first prospective study to collect data on the use of IRIS. Twenty consecutive unconscious patients requiring enteral nutrition were recruited at a single center. IRIS placement was considered complete when a clear image of the gastric mucosa appeared. Correct placement was confirmed using a contrast-enhanced abdominal X-ray. To evaluate the device performance over time, the camera was activated every other day up to 17 d postplacement. In 7 (35%) patients, the trachea was initially visualized, requiring a second placement attempt with the same tube. The IRIS camera allowed recognition of the gastric mucosa in 18 (90%) patients. The esophagogastric junction was identified in one patient, while in a second patient the quality of visualization was poor. Contrast-enhanced X-ray confirmed the gastric placement of IRIS in all patients. IRIS allowed identification of gastric mucosa in 14 (70%) patients 3 d after placement. Performance progressively declined with time (P = 0.006, chi-square for trend). IRIS placement could have spared X-ray confirmation in almost all patients and prevented misplacement into the airway in about one third. Visualization quality needs to be improved, particularly after the first week. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Secure and Robust Iris Recognition Using Random Projections and Sparse Representations.

    PubMed

    Pillai, Jaishanker K; Patel, Vishal M; Chellappa, Rama; Ratha, Nalini K

    2011-09-01

    Noncontact biometrics such as face and iris have additional benefits over contact-based biometrics such as fingerprint and hand geometry. However, three important challenges need to be addressed in a noncontact biometrics-based authentication system: ability to handle unconstrained acquisition, robust and accurate matching, and privacy enhancement without compromising security. In this paper, we propose a unified framework based on random projections and sparse representations, that can simultaneously address all three issues mentioned above in relation to iris biometrics. Our proposed quality measure can handle segmentation errors and a wide variety of possible artifacts during iris acquisition. We demonstrate how the proposed approach can be easily extended to handle alignment variations and recognition from iris videos, resulting in a robust and accurate system. The proposed approach includes enhancements to privacy and security by providing ways to create cancelable iris templates. Results on public data sets show significant benefits of the proposed approach.

  4. Accurate Iris Recognition at a Distance Using Stabilized Iris Encoding and Zernike Moments Phase Features.

    PubMed

    Tan, Chun-Wei; Kumar, Ajay

    2014-07-10

    Accurate iris recognition from the distantly acquired face or eye images requires development of effective strategies which can account for significant variations in the segmented iris image quality. Such variations can be highly correlated with the consistency of encoded iris features and the knowledge that such fragile bits can be exploited to improve matching accuracy. A non-linear approach to simultaneously account for both local consistency of iris bit and also the overall quality of the weight map is proposed. Our approach therefore more effectively penalizes the fragile bits while simultaneously rewarding more consistent bits. In order to achieve more stable characterization of local iris features, a Zernike moment-based phase encoding of iris features is proposed. Such Zernike moments-based phase features are computed from the partially overlapping regions to more effectively accommodate local pixel region variations in the normalized iris images. A joint strategy is adopted to simultaneously extract and combine both the global and localized iris features. The superiority of the proposed iris matching strategy is ascertained by providing comparison with several state-of-the-art iris matching algorithms on three publicly available databases: UBIRIS.v2, FRGC, CASIA.v4-distance. Our experimental results suggest that proposed strategy can achieve significant improvement in iris matching accuracy over those competing approaches in the literature, i.e., average improvement of 54.3%, 32.7% and 42.6% in equal error rates, respectively for UBIRIS.v2, FRGC, CASIA.v4-distance.

  5. A novel iris localization algorithm using correlation filtering

    NASA Astrophysics Data System (ADS)

    Pohit, Mausumi; Sharma, Jitu

    2015-06-01

    Fast and efficient segmentation of iris from the eye images is a primary requirement for robust database independent iris recognition. In this paper we have presented a new algorithm for computing the inner and outer boundaries of the iris and locating the pupil centre. Pupil-iris boundary computation is based on correlation filtering approach, whereas iris-sclera boundary is determined through one dimensional intensity mapping. The proposed approach is computationally less extensive when compared with the existing algorithms like Hough transform.

  6. Iris recognition: on the segmentation of degraded images acquired in the visible wavelength.

    PubMed

    Proença, Hugo

    2010-08-01

    Iris recognition imaging constraints are receiving increasing attention. There are several proposals to develop systems that operate in the visible wavelength and in less constrained environments. These imaging conditions engender acquired noisy artifacts that lead to severely degraded images, making iris segmentation a major issue. Having observed that existing iris segmentation methods tend to fail in these challenging conditions, we present a segmentation method that can handle degraded images acquired in less constrained conditions. We offer the following contributions: 1) to consider the sclera the most easily distinguishable part of the eye in degraded images, 2) to propose a new type of feature that measures the proportion of sclera in each direction and is fundamental in segmenting the iris, and 3) to run the entire procedure in deterministically linear time in respect to the size of the image, making the procedure suitable for real-time applications.

  7. Survey of Technologies for the Airport Border of the Future

    DTIC Science & Technology

    2014-04-01

    geometry Handwriting recognition ID cards Image classification Image enhancement Image fusion Image matching Image processing Image segmentation Iris...00 Tongue print Footstep recognition Odour recognition Retinal recognition Emotion recognition Periocular recognition Handwriting recognition Ear...recognition Palmprint recognition Hand geometry DNA matching Vein matching Ear recognition Handwriting recognition Periocular recognition Emotion

  8. Face Recognition with the Karhunen-Loeve Transform

    DTIC Science & Technology

    1991-12-01

    anthropometry community? 1-2 Methodology As part of this thesis, face recognition software is developed on the Silicon Graphics 4D Personal Iris...the anthropometry community. Standards The most important performance criteria is classification accuracy which is the per- centage of correct...demonstrated by Tarr (24). Reconstructed Output Image yl y2 ... y64 16 hidden layer units xl x2 ... x64 Input 64 by 64 pixel Image Figure 2.6. After the

  9. Comments on the CASIA version 1.0 iris data set.

    PubMed

    Phillips, P Jonathon; Bowyer, Kevin W; Flynn, Patrick J

    2007-10-01

    We note that the images in the CASIA version 1.0 iris dataset have been edited so that the pupil area is replaced by a circular region of uniform intensity. We recommend that this dataset is no longer used in iris biometrics research, unless there this a compelling reason that takes into account the nature of the images. In addition, based on our experience with the Iris Challenge Evaluation (ICE) 2005 technology development project, we make recommendations for reporting results of iris recognition experiments.

  10. [Electronic Device for Retinal and Iris Imaging].

    PubMed

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  11. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis.

    PubMed

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Wang, Wei; Tien, Chung-Hao

    2018-03-06

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  12. Monitoring Reading Behavior: Criteria for Performance.

    ERIC Educational Resources Information Center

    Powell, William R.

    Effective use of the informal reading inventory (IRI) depends upon the criteria used in determining the functional reading levels and more specifically the word recognition criteria employed in describing acceptable limits of oral reading behavior. The author of this paper looks at the diverse sets of criteria commonly used, the problems…

  13. Video-based noncooperative iris image segmentation.

    PubMed

    Du, Yingzi; Arslanturk, Emrah; Zhou, Zhi; Belcher, Craig

    2011-02-01

    In this paper, we propose a video-based noncooperative iris image segmentation scheme that incorporates a quality filter to quickly eliminate images without an eye, employs a coarse-to-fine segmentation scheme to improve the overall efficiency, uses a direct least squares fitting of ellipses method to model the deformed pupil and limbic boundaries, and develops a window gradient-based method to remove noise in the iris region. A remote iris acquisition system is set up to collect noncooperative iris video images. An objective method is used to quantitatively evaluate the accuracy of the segmentation results. The experimental results demonstrate the effectiveness of this method. The proposed method would make noncooperative iris recognition or iris surveillance possible.

  14. Score level fusion scheme based on adaptive local Gabor features for face-iris-fingerprint multimodal biometric

    NASA Astrophysics Data System (ADS)

    He, Fei; Liu, Yuanning; Zhu, Xiaodong; Huang, Chun; Han, Ye; Chen, Ying

    2014-05-01

    A multimodal biometric system has been considered a promising technique to overcome the defects of unimodal biometric systems. We have introduced a fusion scheme to gain a better understanding and fusion method for a face-iris-fingerprint multimodal biometric system. In our case, we use particle swarm optimization to train a set of adaptive Gabor filters in order to achieve the proper Gabor basic functions for each modality. For a closer analysis of texture information, two different local Gabor features for each modality are produced by the corresponding Gabor coefficients. Next, all matching scores of the two Gabor features for each modality are projected to a single-scalar score via a trained, supported, vector regression model for a final decision. A large-scale dataset is formed to validate the proposed scheme using the Facial Recognition Technology database-fafb and CASIA-V3-Interval together with FVC2004-DB2a datasets. The experimental results demonstrate that as well as achieving further powerful local Gabor features of multimodalities and obtaining better recognition performance by their fusion strategy, our architecture also outperforms some state-of-the-art individual methods and other fusion approaches for face-iris-fingerprint multimodal biometric systems.

  15. Integrating image quality in 2nu-SVM biometric match score fusion.

    PubMed

    Vatsa, Mayank; Singh, Richa; Noore, Afzel

    2007-10-01

    This paper proposes an intelligent 2nu-support vector machine based match score fusion algorithm to improve the performance of face and iris recognition by integrating the quality of images. The proposed algorithm applies redundant discrete wavelet transform to evaluate the underlying linear and non-linear features present in the image. A composite quality score is computed to determine the extent of smoothness, sharpness, noise, and other pertinent features present in each subband of the image. The match score and the corresponding quality score of an image are fused using 2nu-support vector machine to improve the verification performance. The proposed algorithm is experimentally validated using the FERET face database and the CASIA iris database. The verification performance and statistical evaluation show that the proposed algorithm outperforms existing fusion algorithms.

  16. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    PubMed Central

    Hsieh, Sheng-Hsun; Wang, Wei; Tien, Chung-Hao

    2018-01-01

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme. PMID:29509692

  17. Dynamic Features for Iris Recognition.

    PubMed

    da Costa, R M; Gonzaga, A

    2012-08-01

    The human eye is sensitive to visible light. Increasing illumination on the eye causes the pupil of the eye to contract, while decreasing illumination causes the pupil to dilate. Visible light causes specular reflections inside the iris ring. On the other hand, the human retina is less sensitive to near infra-red (NIR) radiation in the wavelength range from 800 nm to 1400 nm, but iris detail can still be imaged with NIR illumination. In order to measure the dynamic movement of the human pupil and iris while keeping the light-induced reflexes from affecting the quality of the digitalized image, this paper describes a device based on the consensual reflex. This biological phenomenon contracts and dilates the two pupils synchronously when illuminating one of the eyes by visible light. In this paper, we propose to capture images of the pupil of one eye using NIR illumination while illuminating the other eye using a visible-light pulse. This new approach extracts iris features called "dynamic features (DFs)." This innovative methodology proposes the extraction of information about the way the human eye reacts to light, and to use such information for biometric recognition purposes. The results demonstrate that these features are discriminating features, and, even using the Euclidean distance measure, an average accuracy of recognition of 99.1% was obtained. The proposed methodology has the potential to be "fraud-proof," because these DFs can only be extracted from living irises.

  18. A statistical investigation into the stability of iris recognition in diverse population sets

    NASA Astrophysics Data System (ADS)

    Howard, John J.; Etter, Delores M.

    2014-05-01

    Iris recognition is increasingly being deployed on population wide scales for important applications such as border security, social service administration, criminal identification and general population management. The error rates for this incredibly accurate form of biometric identification are established using well known, laboratory quality datasets. However, it is has long been acknowledged in biometric theory that not all individuals have the same likelihood of being correctly serviced by a biometric system. Typically, techniques for identifying clients that are likely to experience a false non-match or a false match error are carried out on a per-subject basis. This research makes the novel hypothesis that certain ethnical denominations are more or less likely to experience a biometric error. Through established statistical techniques, we demonstrate this hypothesis to be true and document the notable effect that the ethnicity of the client has on iris similarity scores. Understanding the expected impact of ethnical diversity on iris recognition accuracy is crucial to the future success of this technology as it is deployed in areas where the target population consists of clientele from a range of geographic backgrounds, such as border crossings and immigration check points.

  19. Biometric Fusion Demonstration System Scientific Report

    DTIC Science & Technology

    2004-03-01

    verification and facial recognition , searching watchlist databases comprised of full or partial facial images or voice recordings. Multiple-biometric...17 2.2.1.1 Fingerprint and Facial Recognition ............................... 17...iv DRDC Ottawa CR 2004 – 056 2.2.1.2 Iris Recognition and Facial Recognition ........................ 18

  20. Efficient iris texture analysis method based on Gabor ordinal measures

    NASA Astrophysics Data System (ADS)

    Tajouri, Imen; Aydi, Walid; Ghorbel, Ahmed; Masmoudi, Nouri

    2017-07-01

    With the remarkably increasing interest directed to the security dimension, the iris recognition process is considered to stand as one of the most versatile technique critically useful for the biometric identification and authentication process. This is mainly due to every individual's unique iris texture. A modestly conceived efficient approach relevant to the feature extraction process is proposed. In the first place, iris zigzag "collarette" is extracted from the rest of the image by means of the circular Hough transform, as it includes the most significant regions lying in the iris texture. In the second place, the linear Hough transform is used for the eyelids' detection purpose while the median filter is applied for the eyelashes' removal. Then, a special technique combining the richness of Gabor features and the compactness of ordinal measures is implemented for the feature extraction process, so that a discriminative feature representation for every individual can be achieved. Subsequently, the modified Hamming distance is used for the matching process. Indeed, the advanced procedure turns out to be reliable, as compared to some of the state-of-the-art approaches, with a recognition rate of 99.98%, 98.12%, and 95.02% on CASIAV1.0, CASIAV3.0, and IIT Delhi V1 iris databases, respectively.

  1. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications

    PubMed Central

    Park, Keunyeol; Song, Minkyu

    2018-01-01

    This paper presents a single-bit CMOS image sensor (CIS) that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC) in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR) logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel) is 2.84 mm2 with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB) on an 8-bit ADC basis at a 50 MHz sampling frequency. PMID:29495273

  2. The Design of a Single-Bit CMOS Image Sensor for Iris Recognition Applications.

    PubMed

    Park, Keunyeol; Song, Minkyu; Kim, Soo Youn

    2018-02-24

    This paper presents a single-bit CMOS image sensor (CIS) that uses a data processing technique with an edge detection block for simple iris segmentation. In order to recognize the iris image, the image sensor conventionally captures high-resolution image data in digital code, extracts the iris data, and then compares it with a reference image through a recognition algorithm. However, in this case, the frame rate decreases by the time required for digital signal conversion of multi-bit digital data through the analog-to-digital converter (ADC) in the CIS. In order to reduce the overall processing time as well as the power consumption, we propose a data processing technique with an exclusive OR (XOR) logic gate to obtain single-bit and edge detection image data instead of multi-bit image data through the ADC. In addition, we propose a logarithmic counter to efficiently measure single-bit image data that can be applied to the iris recognition algorithm. The effective area of the proposed single-bit image sensor (174 × 144 pixel) is 2.84 mm² with a 0.18 μm 1-poly 4-metal CMOS image sensor process. The power consumption of the proposed single-bit CIS is 2.8 mW with a 3.3 V of supply voltage and 520 frame/s of the maximum frame rates. The error rate of the ADC is 0.24 least significant bit (LSB) on an 8-bit ADC basis at a 50 MHz sampling frequency.

  3. Ocular biometrics by score-level fusion of disparate experts.

    PubMed

    Proença, Hugo

    2014-12-01

    The concept of periocular biometrics emerged to improve the robustness of iris recognition to degraded data. Being a relatively recent topic, most of the periocular recognition algorithms work in a holistic way and apply a feature encoding/matching strategy without considering each biological component in the periocular area. This not only augments the correlation between the components in the resulting biometric signature, but also increases the sensitivity to particular data covariates. The main novelty in this paper is to propose a periocular recognition ensemble made of two disparate components: 1) one expert analyses the iris texture and exhaustively exploits the multispectral information in visible-light data and 2) another expert parameterizes the shape of eyelids and defines a surrounding dimensionless region-of-interest, from where statistics of the eyelids, eyelashes, and skin wrinkles/furrows are encoded. Both experts work on disjoint regions of the periocular area and meet three important properties. First, they produce practically independent responses, which is behind the better performance of the ensemble when compared to the best individual recognizer. Second, they do not share particularly sensitivity to any image covariate, which accounts for augmenting the robustness against degraded data. Finally, it should be stressed that we disregard information in the periocular region that can be easily forged (e.g., shape of eyebrows), which constitutes an active anticounterfeit measure. An empirical evaluation was conducted on two public data sets (FRGC and UBIRIS.v2), and points for consistent improvements in performance of the proposed ensemble over the state-of-the-art periocular recognition algorithms.

  4. Ordinal feature selection for iris and palmprint recognition.

    PubMed

    Sun, Zhenan; Wang, Libin; Tan, Tieniu

    2014-09-01

    Ordinal measures have been demonstrated as an effective feature representation model for iris and palmprint recognition. However, ordinal measures are a general concept of image analysis and numerous variants with different parameter settings, such as location, scale, orientation, and so on, can be derived to construct a huge feature space. This paper proposes a novel optimization formulation for ordinal feature selection with successful applications to both iris and palmprint recognition. The objective function of the proposed feature selection method has two parts, i.e., misclassification error of intra and interclass matching samples and weighted sparsity of ordinal feature descriptors. Therefore, the feature selection aims to achieve an accurate and sparse representation of ordinal measures. And, the optimization subjects to a number of linear inequality constraints, which require that all intra and interclass matching pairs are well separated with a large margin. Ordinal feature selection is formulated as a linear programming (LP) problem so that a solution can be efficiently obtained even on a large-scale feature pool and training database. Extensive experimental results demonstrate that the proposed LP formulation is advantageous over existing feature selection methods, such as mRMR, ReliefF, Boosting, and Lasso for biometric recognition, reporting state-of-the-art accuracy on CASIA and PolyU databases.

  5. Scheimpflug with computational imaging to extend the depth of field of iris recognition systems

    NASA Astrophysics Data System (ADS)

    Sinharoy, Indranil

    Despite the enormous success of iris recognition in close-range and well-regulated spaces for biometric authentication, it has hitherto failed to gain wide-scale adoption in less controlled, public environments. The problem arises from a limitation in imaging called the depth of field (DOF): the limited range of distances beyond which subjects appear blurry in the image. The loss of spatial details in the iris image outside the small DOF limits the iris image capture to a small volume-the capture volume. Existing techniques to extend the capture volume are usually expensive, computationally intensive, or afflicted by noise. Is there a way to combine the classical Scheimpflug principle with the modern computational imaging techniques to extend the capture volume? The solution we found is, surprisingly, simple; yet, it provides several key advantages over existing approaches. Our method, called Angular Focus Stacking (AFS), consists of capturing a set of images while rotating the lens, followed by registration, and blending of the in-focus regions from the images in the stack. The theoretical underpinnings of AFS arose from a pair of new and general imaging models we developed for Scheimpflug imaging that directly incorporates the pupil parameters. The model revealed that we could register the images in the stack analytically if we pivot the lens at the center of its entrance pupil, rendering the registration process exact. Additionally, we found that a specific lens design further reduces the complexity of image registration making AFS suitable for real-time performance. We have demonstrated up to an order of magnitude improvement in the axial capture volume over conventional image capture without sacrificing optical resolution and signal-to-noise ratio. The total time required for capturing the set of images for AFS is less than the time needed for a single-exposure, conventional image for the same DOF and brightness level. The net reduction in capture time can significantly relax the constraints on subject movement during iris acquisition, making it less restrictive.

  6. Democracy, Social Justice and Education: Feminist Strategies in a Globalising World

    ERIC Educational Resources Information Center

    Enslin, Penny

    2006-01-01

    Recognising the relevance of Iris Marion Young's work to education, this article poses the question: given Iris Young's commitment to both social justice and to recognition of the political and ethical significance of difference, to what extent does her position allow for transnational interventions in education to foster democracy? First, it…

  7. Multi-Patches IRIS Based Person Authentication System Using Particle Swarm Optimization and Fuzzy C-Means Clustering

    NASA Astrophysics Data System (ADS)

    Shekar, B. H.; Bhat, S. S.

    2017-05-01

    Locating the boundary parameters of pupil and iris and segmenting the noise free iris portion are the most challenging phases of an automated iris recognition system. In this paper, we have presented person authentication frame work which uses particle swarm optimization (PSO) to locate iris region and circular hough transform (CHT) to device the boundary parameters. To undermine the effect of the noise presented in the segmented iris region we have divided the candidate region into N patches and used Fuzzy c-means clustering (FCM) to classify the patches into best iris region and not so best iris region (noisy region) based on the probability density function of each patch. Weighted mean Hammimng distance is adopted to find the dissimilarity score between the two candidate irises. We have used Log-Gabor, Riesz and Taylor's series expansion (TSE) filters and combinations of these three for iris feature extraction. To justify the feasibility of the proposed method, we experimented on the three publicly available data sets IITD, MMU v-2 and CASIA v-4 distance.

  8. Joint Feature Extraction and Classifier Design for ECG-Based Biometric Recognition.

    PubMed

    Gutta, Sandeep; Cheng, Qi

    2016-03-01

    Traditional biometric recognition systems often utilize physiological traits such as fingerprint, face, iris, etc. Recent years have seen a growing interest in electrocardiogram (ECG)-based biometric recognition techniques, especially in the field of clinical medicine. In existing ECG-based biometric recognition methods, feature extraction and classifier design are usually performed separately. In this paper, a multitask learning approach is proposed, in which feature extraction and classifier design are carried out simultaneously. Weights are assigned to the features within the kernel of each task. We decompose the matrix consisting of all the feature weights into sparse and low-rank components. The sparse component determines the features that are relevant to identify each individual, and the low-rank component determines the common feature subspace that is relevant to identify all the subjects. A fast optimization algorithm is developed, which requires only the first-order information. The performance of the proposed approach is demonstrated through experiments using the MIT-BIH Normal Sinus Rhythm database.

  9. United States Homeland Security and National Biometric Identification

    DTIC Science & Technology

    2002-04-09

    security number. Biometrics is the use of unique individual traits such as fingerprints, iris eye patterns, voice recognition, and facial recognition to...technology to control access onto their military bases using a Defense Manpower Management Command developed software application. FACIAL Facial recognition systems...installed facial recognition systems in conjunction with a series of 200 cameras to fight street crime and identify terrorists. The cameras, which are

  10. Theory of Mind and Empathy in Children With ADHD.

    PubMed

    Maoz, Hagai; Gvirts, Hila Z; Sheffer, Maya; Bloch, Yuval

    2017-05-01

    The current study compared empathy and theory of mind (ToM) between children with ADHD and healthy controls, and assessed changes in ToM among children with ADHD following administration of methylphenidate (MPH). Twenty-four children with ADHD (mean age = 10.3 years) were compared with 36 healthy controls. All children completed the interpersonal reactivity index (IRI), a self-reported empathy questionnaire, and performed the "faux-pas" recognition task (FPR). Children with ADHD performed the task with and without MPH. Children with ADHD showed significantly lower levels of self-reported empathy on most IRI subscales. FPR scores were significantly lower in children with ADHD and were improved, following the administration of MPH, to a level equal to that found in healthy controls. Children with ADHD show impaired self-reported empathy and FPR when compared with healthy controls. Stimulants improve FPR in children with ADHD to a level equal to that in healthy controls.

  11. Improving Protein Fold Recognition by Deep Learning Networks.

    PubMed

    Jo, Taeho; Hou, Jie; Eickholt, Jesse; Cheng, Jianlin

    2015-12-04

    For accurate recognition of protein folds, a deep learning network method (DN-Fold) was developed to predict if a given query-template protein pair belongs to the same structural fold. The input used stemmed from the protein sequence and structural features extracted from the protein pair. We evaluated the performance of DN-Fold along with 18 different methods on Lindahl's benchmark dataset and on a large benchmark set extracted from SCOP 1.75 consisting of about one million protein pairs, at three different levels of fold recognition (i.e., protein family, superfamily, and fold) depending on the evolutionary distance between protein sequences. The correct recognition rate of ensembled DN-Fold for Top 1 predictions is 84.5%, 61.5%, and 33.6% and for Top 5 is 91.2%, 76.5%, and 60.7% at family, superfamily, and fold levels, respectively. We also evaluated the performance of single DN-Fold (DN-FoldS), which showed the comparable results at the level of family and superfamily, compared to ensemble DN-Fold. Finally, we extended the binary classification problem of fold recognition to real-value regression task, which also show a promising performance. DN-Fold is freely available through a web server at http://iris.rnet.missouri.edu/dnfold.

  12. Toward accurate and fast iris segmentation for iris biometrics.

    PubMed

    He, Zhaofeng; Tan, Tieniu; Sun, Zhenan; Qiu, Xianchao

    2009-09-01

    Iris segmentation is an essential module in iris recognition because it defines the effective image region used for subsequent processing such as feature extraction. Traditional iris segmentation methods often involve an exhaustive search of a large parameter space, which is time consuming and sensitive to noise. To address these problems, this paper presents a novel algorithm for accurate and fast iris segmentation. After efficient reflection removal, an Adaboost-cascade iris detector is first built to extract a rough position of the iris center. Edge points of iris boundaries are then detected, and an elastic model named pulling and pushing is established. Under this model, the center and radius of the circular iris boundaries are iteratively refined in a way driven by the restoring forces of Hooke's law. Furthermore, a smoothing spline-based edge fitting scheme is presented to deal with noncircular iris boundaries. After that, eyelids are localized via edge detection followed by curve fitting. The novelty here is the adoption of a rank filter for noise elimination and a histogram filter for tackling the shape irregularity of eyelids. Finally, eyelashes and shadows are detected via a learned prediction model. This model provides an adaptive threshold for eyelash and shadow detection by analyzing the intensity distributions of different iris regions. Experimental results on three challenging iris image databases demonstrate that the proposed algorithm outperforms state-of-the-art methods in both accuracy and speed.

  13. Iris recognition using image moments and k-means algorithm.

    PubMed

    Khan, Yaser Daanial; Khan, Sher Afzal; Ahmad, Farooq; Islam, Saeed

    2014-01-01

    This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%.

  14. Iris Recognition Using Image Moments and k-Means Algorithm

    PubMed Central

    Khan, Yaser Daanial; Khan, Sher Afzal; Ahmad, Farooq; Islam, Saeed

    2014-01-01

    This paper presents a biometric technique for identification of a person using the iris image. The iris is first segmented from the acquired image of an eye using an edge detection algorithm. The disk shaped area of the iris is transformed into a rectangular form. Described moments are extracted from the grayscale image which yields a feature vector containing scale, rotation, and translation invariant moments. Images are clustered using the k-means algorithm and centroids for each cluster are computed. An arbitrary image is assumed to belong to the cluster whose centroid is the nearest to the feature vector in terms of Euclidean distance computed. The described model exhibits an accuracy of 98.5%. PMID:24977221

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barstow, Del R; Patlolla, Dilip Reddy; Mann, Christopher J

    Abstract The data captured by existing standoff biometric systems typically has lower biometric recognition performance than their close range counterparts due to imaging challenges, pose challenges, and other factors. To assist in overcoming these limitations systems typically perform in a multi-modal capacity such as Honeywell s Combined Face and Iris (CFAIRS) [21] system. While this improves the systems performance, standoff systems have yet to be proven as accurate as their close range equivalents. We will present a standoff system capable of operating up to 7 meters in range. Unlike many systems such as the CFAIRS our system captures high qualitymore » 12 MP video allowing for a multi-sample as well as multi-modal comparison. We found that for standoff systems multi-sample improved performance more than multi-modal. For a small test group of 50 subjects we were able to achieve 100% rank one recognition performance with our system.« less

  16. Ethics, Identity and Culture: Some Implications of the Moral Philosophy of Iris Murdoch.

    ERIC Educational Resources Information Center

    Weldhen, Margaret

    1986-01-01

    Reviews the work of Iris Murdoch, a moral philosopher who maintains that the work of moral education is the recognition of the phenomenology of inner moral experience and the struggle to express it. Shows how important this view of the inner meaning of moral experience, often expressed as metaphor, is to identity, culture, and education.…

  17. Unified framework for automated iris segmentation using distantly acquired face images.

    PubMed

    Tan, Chun-Wei; Kumar, Ajay

    2012-09-01

    Remote human identification using iris biometrics has high civilian and surveillance applications and its success requires the development of robust segmentation algorithm to automatically extract the iris region. This paper presents a new iris segmentation framework which can robustly segment the iris images acquired using near infrared or visible illumination. The proposed approach exploits multiple higher order local pixel dependencies to robustly classify the eye region pixels into iris or noniris regions. Face and eye detection modules have been incorporated in the unified framework to automatically provide the localized eye region from facial image for iris segmentation. We develop robust postprocessing operations algorithm to effectively mitigate the noisy pixels caused by the misclassification. Experimental results presented in this paper suggest significant improvement in the average segmentation errors over the previously proposed approaches, i.e., 47.5%, 34.1%, and 32.6% on UBIRIS.v2, FRGC, and CASIA.v4 at-a-distance databases, respectively. The usefulness of the proposed approach is also ascertained from recognition experiments on three different publicly available databases.

  18. Use of iris recognition camera technology for the quantification of corneal opacification in mucopolysaccharidoses.

    PubMed

    Aslam, Tariq Mehmood; Shakir, Savana; Wong, James; Au, Leon; Ashworth, Jane

    2012-12-01

    Mucopolysaccharidoses (MPS) can cause corneal opacification that is currently difficult to objectively quantify. With newer treatments for MPS comes an increased need for a more objective, valid and reliable index of disease severity for clinical and research use. Clinical evaluation by slit lamp is very subjective and techniques based on colour photography are difficult to standardise. In this article the authors present evidence for the utility of dedicated image analysis algorithms applied to images obtained by a highly sophisticated iris recognition camera that is small, manoeuvrable and adapted to achieve rapid, reliable and standardised objective imaging in a wide variety of patients while minimising artefactual interference in image quality.

  19. Improving Protein Fold Recognition by Deep Learning Networks

    NASA Astrophysics Data System (ADS)

    Jo, Taeho; Hou, Jie; Eickholt, Jesse; Cheng, Jianlin

    2015-12-01

    For accurate recognition of protein folds, a deep learning network method (DN-Fold) was developed to predict if a given query-template protein pair belongs to the same structural fold. The input used stemmed from the protein sequence and structural features extracted from the protein pair. We evaluated the performance of DN-Fold along with 18 different methods on Lindahl’s benchmark dataset and on a large benchmark set extracted from SCOP 1.75 consisting of about one million protein pairs, at three different levels of fold recognition (i.e., protein family, superfamily, and fold) depending on the evolutionary distance between protein sequences. The correct recognition rate of ensembled DN-Fold for Top 1 predictions is 84.5%, 61.5%, and 33.6% and for Top 5 is 91.2%, 76.5%, and 60.7% at family, superfamily, and fold levels, respectively. We also evaluated the performance of single DN-Fold (DN-FoldS), which showed the comparable results at the level of family and superfamily, compared to ensemble DN-Fold. Finally, we extended the binary classification problem of fold recognition to real-value regression task, which also show a promising performance. DN-Fold is freely available through a web server at http://iris.rnet.missouri.edu/dnfold.

  20. The International Reference Ionosphere: Rawer's IRI and its status today

    NASA Astrophysics Data System (ADS)

    Bilitza, D.

    2014-11-01

    When the Committee on Space Research (COSPAR) initiated the International Reference Ionosphere (IRI) project in 1968 it wisely selected K. Rawer as its first Chairperson. With a solid footing and good contacts in both the ground-based and space-based ionospheric communities he was ideally suited to pull together colleagues and data from both communities to help build the first version of the IRI. He assembled a team of 20+ international ionospheric experts in the IRI Working Group and chaired and directed the group from 1968 to 1984. The working group has now grown to 63 members and the IRI model has undergone many revisions as new data became available and new modeling techniques were applied. This paper was presented during a special session of the Kleinheubach Tagung 2013 in honor of K. Rawer's 100th birthday. It will review the current status of the IRI model and project and the international recognition it has achieved. It is quite fitting that this year we not only celebrate K. Rawer's 100th birthday but also the exciting news that his favorite science endeavor, IRI, has been internationally recognized as an ISO (International Standardization Organization) standard. The IRI homepage is at http://irimodel.org.

  1. Comparative analysis of classification based algorithms for diabetes diagnosis using iris images.

    PubMed

    Samant, Piyush; Agarwal, Ravinder

    2018-01-01

    Photo-diagnosis is always an intriguing area for the researchers, with the advancement of image processing and computer machine vision techniques it have become more reliable and popular in recent years. The objective of this paper is to study the change in the features of iris, particularly irregularities in the pigmentation of certain areas of the iris with respect to diabetic health of an individual. Apart from the point that iris recognition concentrates on the overall structure of the iris, diagnostic techniques emphasises the local variations in the particular area of iris. Pre-image processing techniques have been applied to extract iris and thereafter, region of interest from the extracted iris have been cropped out. In order to observe the changes in the tissue pigmentation of region of interest, statistical, texture textural and wavelet features have been extracted. At the end, a comparison of accuracies of five different classifiers has been presented to classify two subject groups of diabetic and non-diabetic. Best classification accuracy has been calculated as 89.66% by the random forest classifier. Results have been shown the effectiveness and diagnostic significance of the proposed methodology. Presented piece of work offers a novel systemic perspective of non-invasive and automatic diabetic diagnosis.

  2. Iris biometric system design using multispectral imaging

    NASA Astrophysics Data System (ADS)

    Widhianto, Benedictus Yohanes Bagus Y. B.; Nasution, Aulia M. T.

    2016-11-01

    An identity recognition system is a vital component that cannot be separated from life, iris biometric is one of the biometric that has the best accuracy reaching 99%. Usually, iris biometric systems use infrared spectrum lighting to reduce discomfort caused by radiation when the eye is given direct light, while the eumelamin that is forming the iris has the most flourescent radiation when given a spectrum of visible light. This research will be conducted by detecting iris wavelengths of 850 nm, 560 nm, and 590 nm, where the detection algorithm will be using Daugman algorithm by using a Gabor wavelet extraction feature, and matching feature using a Hamming distance. Results generated will be analyzed to identify how much differences there are, and to improve the accuracy of the multispectral biometric system and as a detector of the authenticity of the iris. The results obtained from the analysis of wavelengths 850 nm, 560 nm, and 590 nm respectively has an accuracy of 99,35 , 97,5 , 64,5 with a matching score of 0,26 , 0,23 , 0,37.

  3. Eye movement identification based on accumulated time feature

    NASA Astrophysics Data System (ADS)

    Guo, Baobao; Wu, Qiang; Sun, Jiande; Yan, Hua

    2017-06-01

    Eye movement is a new kind of feature for biometrical recognition, it has many advantages compared with other features such as fingerprint, face, and iris. It is not only a sort of static characteristics, but also a combination of brain activity and muscle behavior, which makes it effective to prevent spoofing attack. In addition, eye movements can be incorporated with faces, iris and other features recorded from the face region into multimode systems. In this paper, we do an exploring study on eye movement identification based on the eye movement datasets provided by Komogortsev et al. in 2011 with different classification methods. The time of saccade and fixation are extracted from the eye movement data as the eye movement features. Furthermore, the performance analysis was conducted on different classification methods such as the BP, RBF, ELMAN and SVM in order to provide a reference to the future research in this field.

  4. Can we recognize horses by their ocular biometric traits using deep convolutional neural networks?

    NASA Astrophysics Data System (ADS)

    Trokielewicz, Mateusz; Szadkowski, Mateusz

    2017-08-01

    This paper aims at determining the viability of horse recognition by the means of ocular biometrics and deep convolutional neural networks (deep CNNs). Fast and accurate identification of race horses before racing is crucial for ensuring that exactly the horses that were declared are participating, using methods that are non-invasive and friendly to these delicate animals. As typical iris recognition methods require lot of fine-tuning of the method parameters and high-quality data, CNNs seem like a natural candidate to be applied for recognition thanks to their potentially excellent abilities in describing texture, combined with ease of implementation in an end-to-end manner. Also, with such approach we can easily utilize both iris and periocular features without constructing complicated algorithms for each. We thus present a simple CNN classifier, able to correctly identify almost 80% of the samples in an identification scenario, and give equal error rate (EER) of less than 10% in a verification scenario.

  5. Reliability of Iris Recognition as a Means of Identity Verification and Future Impact on Transportation Worker Identification Credential

    DTIC Science & Technology

    2008-03-01

    80 5. Time Frame of the Experiment...81 6. Eyeglasses ............................................................................................81 D. OBSERVED RESULTS...97 2. Eyeglasses are a Factor

  6. Case for a field-programmable gate array multicore hybrid machine for an image-processing application

    NASA Astrophysics Data System (ADS)

    Rakvic, Ryan N.; Ives, Robert W.; Lira, Javier; Molina, Carlos

    2011-01-01

    General purpose computer designers have recently begun adding cores to their processors in order to increase performance. For example, Intel has adopted a homogeneous quad-core processor as a base for general purpose computing. PlayStation3 (PS3) game consoles contain a multicore heterogeneous processor known as the Cell, which is designed to perform complex image processing algorithms at a high level. Can modern image-processing algorithms utilize these additional cores? On the other hand, modern advancements in configurable hardware, most notably field-programmable gate arrays (FPGAs) have created an interesting question for general purpose computer designers. Is there a reason to combine FPGAs with multicore processors to create an FPGA multicore hybrid general purpose computer? Iris matching, a repeatedly executed portion of a modern iris-recognition algorithm, is parallelized on an Intel-based homogeneous multicore Xeon system, a heterogeneous multicore Cell system, and an FPGA multicore hybrid system. Surprisingly, the cheaper PS3 slightly outperforms the Intel-based multicore on a core-for-core basis. However, both multicore systems are beaten by the FPGA multicore hybrid system by >50%.

  7. A Grey Wolf Optimizer for Modular Granular Neural Networks for Human Recognition

    PubMed Central

    Sánchez, Daniela; Melin, Patricia

    2017-01-01

    A grey wolf optimizer for modular neural network (MNN) with a granular approach is proposed. The proposed method performs optimal granulation of data and design of modular neural networks architectures to perform human recognition, and to prove its effectiveness benchmark databases of ear, iris, and face biometric measures are used to perform tests and comparisons against other works. The design of a modular granular neural network (MGNN) consists in finding optimal parameters of its architecture; these parameters are the number of subgranules, percentage of data for the training phase, learning algorithm, goal error, number of hidden layers, and their number of neurons. Nowadays, there is a great variety of approaches and new techniques within the evolutionary computing area, and these approaches and techniques have emerged to help find optimal solutions to problems or models and bioinspired algorithms are part of this area. In this work a grey wolf optimizer is proposed for the design of modular granular neural networks, and the results are compared against a genetic algorithm and a firefly algorithm in order to know which of these techniques provides better results when applied to human recognition. PMID:28894461

  8. A Grey Wolf Optimizer for Modular Granular Neural Networks for Human Recognition.

    PubMed

    Sánchez, Daniela; Melin, Patricia; Castillo, Oscar

    2017-01-01

    A grey wolf optimizer for modular neural network (MNN) with a granular approach is proposed. The proposed method performs optimal granulation of data and design of modular neural networks architectures to perform human recognition, and to prove its effectiveness benchmark databases of ear, iris, and face biometric measures are used to perform tests and comparisons against other works. The design of a modular granular neural network (MGNN) consists in finding optimal parameters of its architecture; these parameters are the number of subgranules, percentage of data for the training phase, learning algorithm, goal error, number of hidden layers, and their number of neurons. Nowadays, there is a great variety of approaches and new techniques within the evolutionary computing area, and these approaches and techniques have emerged to help find optimal solutions to problems or models and bioinspired algorithms are part of this area. In this work a grey wolf optimizer is proposed for the design of modular granular neural networks, and the results are compared against a genetic algorithm and a firefly algorithm in order to know which of these techniques provides better results when applied to human recognition.

  9. Dependency of Optimal Parameters of the IRIS Template on Image Quality and Border Detection Error

    NASA Astrophysics Data System (ADS)

    Matveev, I. A.; Novik, V. P.

    2017-05-01

    Generation of a template containing spatial-frequency features of iris is an important stage of identification. The template is obtained by a wavelet transform in an image region specified by iris borders. One of the main characteristics of the identification system is the value of recognition error, equal error rate (EER) is used as criterion here. The optimal values (in sense of minimizing the EER) of wavelet transform parameters depend on many factors: image quality, sharpness, size of characteristic objects, etc. It is hard to isolate these factors and their influences. The work presents an attempt to study an influence of following factors to EER: iris segmentation precision, defocus level, noise level. Several public domain iris image databases were involved in experiments. The images were subjected to modelled distortions of said types. The dependencies of wavelet parameter and EER values from the distortion levels were build. It is observed that the increase of the segmentation error and image noise leads to the increase of the optimal wavelength of the wavelets, whereas the increase of defocus level leads to decreasing of this value.

  10. Extended depth of field in an intrinsically wavefront-encoded biometric iris camera

    NASA Astrophysics Data System (ADS)

    Bergkoetter, Matthew D.; Bentley, Julie L.

    2014-12-01

    This work describes a design process which greatly increases the depth of field of a simple three-element lens system intended for biometric iris recognition. The system is optimized to produce a point spread function which is insensitive to defocus, so that recorded images may be deconvolved without knowledge of the exact object distance. This is essentially a variation on the technique of wavefront encoding, however the desired encoding effect is achieved by aberrations intrinsic to the lens system itself, without the need for a pupil phase mask.

  11. Who Goes There?

    ERIC Educational Resources Information Center

    Vail, Kathleen

    1995-01-01

    Biometrics (hand geometry, iris and retina scanners, voice and facial recognition, signature dynamics, facial thermography, and fingerprint readers) identifies people based on physical characteristics. Administrators worried about kidnapping, vandalism, theft, and violent intruders might welcome these security measures when they become more…

  12. Improved Hip-Based Individual Recognition Using Wearable Motion Recording Sensor

    NASA Astrophysics Data System (ADS)

    Gafurov, Davrondzhon; Bours, Patrick

    In todays society the demand for reliable verification of a user identity is increasing. Although biometric technologies based on fingerprint or iris can provide accurate and reliable recognition performance, they are inconvenient for periodic or frequent re-verification. In this paper we propose a hip-based user recognition method which can be suitable for implicit and periodic re-verification of the identity. In our approach we use a wearable accelerometer sensor attached to the hip of the person, and then the measured hip motion signal is analysed for identity verification purposes. The main analyses steps consists of detecting gait cycles in the signal and matching two sets of detected gait cycles. Evaluating the approach on a hip data set consisting of 400 gait sequences (samples) from 100 subjects, we obtained equal error rate (EER) of 7.5% and identification rate at rank 1 was 81.4%. These numbers are improvements by 37.5% and 11.2% respectively of the previous study using the same data set.

  13. Assessing for domestic violence in sexual health environments: a qualitative study.

    PubMed

    Horwood, Jeremy; Morden, Andrew; Bailey, Jayne E; Pathak, Neha; Feder, Gene

    2018-03-01

    Domestic violence and abuse (DVA) is a major clinical challenge and public health issue. Sexual health services are an important potential site of DVA intervention. The Assessing for Domestic Violence in Sexual Health Environments (ADViSE) intervention aimed to improve identification and management of DVA in sexual healthcare settings and is a modified version of the Identification and Referral to Improve Safety (IRIS) general practice programme. Our qualitative evaluation aimed to explore the experiences of staff participating in an IRIS ADViSE pilot. Interviews were conducted with 17 sexual health clinic staff and DVA advocate workers. Interviews were audio recorded, transcribed, anonymised and analysed thematically. Staff prioritised enquiring about DVA and tailored their style of enquiry to the perceived characteristics of patients, current workload and individual clinical judgements. Responding to disclosures of abuse was divided between perceived low-risk cases (with quick onwards referral) and high-risk cases (requiring deployment of institution safeguarding procedures), which were viewed as time consuming and could create tensions with patients. Ongoing training and feedback, commissioner recognition, adequate service-level agreements and reimbursements are required to ensure sustainability and wider implementation of IRIS ADViSE. Challenges of delivering and sustaining IRIS ADViSE included the varied styles of enquiry, as well as tensions and additional time pressure arising from disclosure of abuse. These can be overcome by modifying initial training, providing regular updates and stronger recognition (and resources) at policy and commissioning levels. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Study of the similarity function in Indexing-First-One hashing

    NASA Astrophysics Data System (ADS)

    Lai, Y.-L.; Jin, Z.; Goi, B.-M.; Chai, T.-Y.

    2017-06-01

    The recent proposed Indexing-First-One (IFO) hashing is a latest technique that is particularly adopted for eye iris template protection, i.e. IrisCode. However, IFO employs the measure of Jaccard Similarity (JS) initiated from Min-hashing has yet been adequately discussed. In this paper, we explore the nature of JS in binary domain and further propose a mathematical formulation to generalize the usage of JS, which is subsequently verified by using CASIA v3-Interval iris database. Our study reveals that JS applied in IFO hashing is a generalized version in measure two input objects with respect to Min-Hashing where the coefficient of JS is equal to one. With this understanding, IFO hashing can propagate the useful properties of Min-hashing, i.e. similarity preservation, thus favorable for similarity searching or recognition in binary space.

  15. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    NASA Astrophysics Data System (ADS)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  16. Extending the depth of field with chromatic aberration for dual-wavelength iris imaging.

    PubMed

    Fitzgerald, Niamh M; Dainty, Christopher; Goncharov, Alexander V

    2017-12-11

    We propose a method of extending the depth of field to twice that achievable by conventional lenses for the purpose of a low cost iris recognition front-facing camera in mobile phones. By introducing intrinsic primary chromatic aberration in the lens, the depth of field is doubled by means of dual wavelength illumination. The lens parameters (radius of curvature, optical power) can be found analytically by using paraxial raytracing. The effective range of distances covered increases with dispersion of the glass chosen and with larger distance for the near object point.

  17. Convolution Comparison Pattern: An Efficient Local Image Descriptor for Fingerprint Liveness Detection

    PubMed Central

    Gottschlich, Carsten

    2016-01-01

    We present a new type of local image descriptor which yields binary patterns from small image patches. For the application to fingerprint liveness detection, we achieve rotation invariant image patches by taking the fingerprint segmentation and orientation field into account. We compute the discrete cosine transform (DCT) for these rotation invariant patches and attain binary patterns by comparing pairs of two DCT coefficients. These patterns are summarized into one or more histograms per image. Each histogram comprises the relative frequencies of pattern occurrences. Multiple histograms are concatenated and the resulting feature vector is used for image classification. We name this novel type of descriptor convolution comparison pattern (CCP). Experimental results show the usefulness of the proposed CCP descriptor for fingerprint liveness detection. CCP outperforms other local image descriptors such as LBP, LPQ and WLD on the LivDet 2013 benchmark. The CCP descriptor is a general type of local image descriptor which we expect to prove useful in areas beyond fingerprint liveness detection such as biological and medical image processing, texture recognition, face recognition and iris recognition, liveness detection for face and iris images, and machine vision for surface inspection and material classification. PMID:26844544

  18. Spatula scaffold: An iris-sparing technique for lensectomy.

    PubMed

    Narang, Priya; Agarwal, Amar

    2017-12-01

    Lensectomy with vitrectomy is often performed for crystalline lenticular subluxation. We report a new technique and a practical approach that involves the placement of a spatula beneath the iris tissue that facilitates retroiridial removal of subluxated lens and acts as a scaffold by protecting the iris tissue from being accidentally trapped into the vitrectomy cutter port. Our technique facilitates management of the lens and vitreous without any trauma to the iris and secondarily obviates the need to perform an iris repair procedure that may arise due to iatrogenic reasons.

  19. Effects of compression and individual variability on face recognition performance

    NASA Astrophysics Data System (ADS)

    McGarry, Delia P.; Arndt, Craig M.; McCabe, Steven A.; D'Amato, Donald P.

    2004-08-01

    The Enhanced Border Security and Visa Entry Reform Act of 2002 requires that the Visa Waiver Program be available only to countries that have a program to issue to their nationals machine-readable passports incorporating biometric identifiers complying with applicable standards established by the International Civil Aviation Organization (ICAO). In June 2002, the New Technologies Working Group of ICAO unanimously endorsed the use of face recognition (FR) as the globally interoperable biometric for machine-assisted identity confirmation with machine-readable travel documents (MRTDs), although Member States may elect to use fingerprint and/or iris recognition as additional biometric technologies. The means and formats are still being developed through which biometric information might be stored in the constrained space of integrated circuit chips embedded within travel documents. Such information will be stored in an open, yet unalterable and very compact format, probably as digitally signed and efficiently compressed images. The objective of this research is to characterize the many factors that affect FR system performance with respect to the legislated mandates concerning FR. A photograph acquisition environment and a commercial face recognition system have been installed at Mitretek, and over 1,400 images have been collected of volunteers. The image database and FR system are being used to analyze the effects of lossy image compression, individual differences, such as eyeglasses and facial hair, and the acquisition environment on FR system performance. Images are compressed by varying ratios using JPEG2000 to determine the trade-off points between recognition accuracy and compression ratio. The various acquisition factors that contribute to differences in FR system performance among individuals are also being measured. The results of this study will be used to refine and test efficient face image interchange standards that ensure highly accurate recognition, both for automated FR systems and human inspectors. Working within the M1-Biometrics Technical Committee of the InterNational Committee for Information Technology Standards (INCITS) organization, a standard face image format will be tested and submitted to organizations such as ICAO.

  20. Novel probabilistic neuroclassifier

    NASA Astrophysics Data System (ADS)

    Hong, Jiang; Serpen, Gursel

    2003-09-01

    A novel probabilistic potential function neural network classifier algorithm to deal with classes which are multi-modally distributed and formed from sets of disjoint pattern clusters is proposed in this paper. The proposed classifier has a number of desirable properties which distinguish it from other neural network classifiers. A complete description of the algorithm in terms of its architecture and the pseudocode is presented. Simulation analysis of the newly proposed neuro-classifier algorithm on a set of benchmark problems is presented. Benchmark problems tested include IRIS, Sonar, Vowel Recognition, Two-Spiral, Wisconsin Breast Cancer, Cleveland Heart Disease and Thyroid Gland Disease. Simulation results indicate that the proposed neuro-classifier performs consistently better for a subset of problems for which other neural classifiers perform relatively poorly.

  1. Comparison between extreme learning machine and wavelet neural networks in data classification

    NASA Astrophysics Data System (ADS)

    Yahia, Siwar; Said, Salwa; Jemai, Olfa; Zaied, Mourad; Ben Amar, Chokri

    2017-03-01

    Extreme learning Machine is a well known learning algorithm in the field of machine learning. It's about a feed forward neural network with a single-hidden layer. It is an extremely fast learning algorithm with good generalization performance. In this paper, we aim to compare the Extreme learning Machine with wavelet neural networks, which is a very used algorithm. We have used six benchmark data sets to evaluate each technique. These datasets Including Wisconsin Breast Cancer, Glass Identification, Ionosphere, Pima Indians Diabetes, Wine Recognition and Iris Plant. Experimental results have shown that both extreme learning machine and wavelet neural networks have reached good results.

  2. Eye contrast polarity is critical for face recognition by infants.

    PubMed

    Otsuka, Yumiko; Motoyoshi, Isamu; Hill, Harold C; Kobayashi, Megumi; Kanazawa, So; Yamaguchi, Masami K

    2013-07-01

    Just as faces share the same basic arrangement of features, with two eyes above a nose above a mouth, human eyes all share the same basic contrast polarity relations, with a sclera lighter than an iris and a pupil, and this is unique among primates. The current study examined whether this bright-dark relationship of sclera to iris plays a critical role in face recognition from early in development. Specifically, we tested face discrimination in 7- and 8-month-old infants while independently manipulating the contrast polarity of the eye region and of the rest of the face. This gave four face contrast polarity conditions: fully positive condition, fully negative condition, positive face with negated eyes ("negative eyes") condition, and negated face with positive eyes ("positive eyes") condition. In a familiarization and novelty preference procedure, we found that 7- and 8-month-olds could discriminate between faces only when the contrast polarity of the eyes was preserved (positive) and that this did not depend on the contrast polarity of the rest of the face. This demonstrates the critical role of eye contrast polarity for face recognition in 7- and 8-month-olds and is consistent with previous findings for adults. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Reliability and Validity of Curriculum-Based Informal Reading Inventories.

    ERIC Educational Resources Information Center

    Fuchs, Lynn; And Others

    A study was conducted to explore the reliability and validity of three prominent procedures used in informal reading inventories (IRIs): (1) choosing a 95% word recognition accuracy standard for determining student instructional level, (2) arbitrarily selecting a passage to represent the difficulty level of a basal reader, and (3) employing…

  4. Alexithymia and Mood: Recognition of Emotion in Self and Others.

    PubMed

    Lyvers, Michael; Kohlsdorf, Susan M; Edwards, Mark S; Thorberg, Fred Arne

    2017-01-01

    The present study explored relationships between alexithymia-a trait characterized by difficulties identifying and describing feelings and an external thinking style-and negative moods, negative mood regulation expectancies, facial recognition of emotions, emotional empathy, and alcohol consumption. The sample consisted of 102 university (primarily psychology) students (13 men, 89 women) aged 18 to 50 years (M = 22.18 years). Participants completed the Toronto Alexithymia Scale (TAS-20), Negative Mood Regulation Scale (NMRS), Depression Anxiety Stress Scales (DASS-21), Reading the Mind in the Eyes Test (RMET), Interpersonal Reactivity Index (IRI), and Alcohol Use Disorders Identification Test (AUDIT). Results were consistent with previous findings of positive relationships of TAS-20 alexithymia scores with both alcohol use (AUDIT) and negative moods (DASS-21) and a negative relationship with emotional self-regulation as indexed by NMRS. Predicted negative associations of both overall TAS-20 alexithymia scores and the externally oriented thinking (EOT) subscale of the TAS-20 with both RMET facial recognition of emotions and the empathic concern (EC) subscale of the IRI were supported. The mood self-regulation index NMRS fully mediated the relationship between alexithymia and negative moods. Hierarchical linear regressions revealed that, after other relevant variables were controlled for, the EOT subscale of the TAS-20 predicted RMET and EC. The concrete thinking or EDT facet of alexithymia thus appears to be associated with diminished facial recognition of emotions and reduced emotional empathy. The negative moods associated with alexithymia appear to be linked to subjective difficulties in self-regulation of emotions.

  5. Iris alterations after DSAEK.

    PubMed

    Del Hierro Zarzuelo, A; Boto de Los Bueis, A

    2016-09-01

    To evaluate a series of case that developed iris changes after performing Descemet's stripping automated endothelial keratoplasty (DSAEK). Retrospective study of eyes that developed iris abnormalities, such as pupil ovalisation, iris atrophy, iridocorneal synechiae, mydriatic pupil, and pigmentary changes after performing DSAEK in a tertiary hospital. In a series of the first 32 DSAEK procedures performed, new single or mixed iris alterations were observed in 12 eyes (37.5%). Iris-corneal synechiae were observed in 7 eyes, corectopias in 9 eyes, iris atrophy in 3 cases, and one case developed an areflexic mydriatic pupil. Long-term pigment dispersion at the edge of the lenticule was observed in 12 eyes. The alterations occurred after three months from the surgery. In the evaluation of the associated factors, malignant glaucoma had occurred in 1 case, 2 eyes had required a second surgery, one case by re-DSAEK, and the other one by removing the intraocular lens due to lens opacification. Two cases had a shallow anterior chamber. No relationship was found between the thickness of the peripheral lenticule and the presence of synechiae. Iris changes regarding DSAEK are possible. A discussion is presented on the relationship between increased intraocular pressure due to air in anterior chamber and its relationship with ischaemia and secondary alterations in the iris. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Immune Reconstitution Reactions in Human Immunodeficiency Virus–Negative Patients

    PubMed Central

    Scharschmidt, Tiffany C.; Amerson, Erin H.; Rosenberg, Oren S.; Jacobs, Richard A.; McCalmont, Timothy H.; Shinkai, Kanade

    2013-01-01

    Background Immune reconstitution inflammatory syndrome (IRIS) is a phenomenon initially described in patients with human immunodeficiency virus. Upon initiation of combination antiretroviral therapy, recovery of cellular immunity triggers inflammation to a preexisting infection or antigen that causes paradoxical worsening of clinical disease. A similar phenomenon can occur in human immunodeficiency virus–negative patients, including pregnant women, neutropenic hosts, solidorgan or stem cell transplant recipients, and patients receiving tumor necrosis factor inhibitors. Observations We report a case of leprosy unmasking and downgrading reaction after stem cell transplantation that highlights some of the challenges inherent to the diagnosis of IRIS, especially in patients without human immunodeficiency virus infection, as well as review the spectrum of previously reported cases of IRIS reactions in this population. Conclusions The mechanism of immune reconstitution reactions is complex and variable, depending on the underlying antigen and the mechanism of immunosuppression or shift in immune status. Use of the term IRIS can aid our recognition of an important phenomenon that occurs in the setting of immunosuppression or shifts in immunity but should not deter us from thinking critically about the distinct processes that underlie this heterogeneous group of conditions. PMID:23324760

  7. Security enhanced BioEncoding for protecting iris codes

    NASA Astrophysics Data System (ADS)

    Ouda, Osama; Tsumura, Norimichi; Nakaguchi, Toshiya

    2011-06-01

    Improving the security of biometric template protection techniques is a key prerequisite for the widespread deployment of biometric technologies. BioEncoding is a recently proposed template protection scheme, based on the concept of cancelable biometrics, for protecting biometric templates represented as binary strings such as iris codes. The main advantage of BioEncoding over other template protection schemes is that it does not require user-specific keys and/or tokens during verification. Besides, it satisfies all the requirements of the cancelable biometrics construct without deteriorating the matching accuracy. However, although it has been shown that BioEncoding is secure enough against simple brute-force search attacks, the security of BioEncoded templates against more smart attacks, such as record multiplicity attacks, has not been sufficiently investigated. In this paper, a rigorous security analysis of BioEncoding is presented. Firstly, resistance of BioEncoded templates against brute-force attacks is revisited thoroughly. Secondly, we show that although the cancelable transformation employed in BioEncoding might be non-invertible for a single protected template, the original iris code could be inverted by correlating several templates used in different applications but created from the same iris. Accordingly, we propose an important modification to the BioEncoding transformation process in order to hinder attackers from exploiting this type of attacks. The effectiveness of adopting the suggested modification is validated and its impact on the matching accuracy is investigated empirically using CASIA-IrisV3-Interval dataset. Experimental results confirm the efficacy of the proposed approach and show that it preserves the matching accuracy of the unprotected iris recognition system.

  8. A DFT-Based Method of Feature Extraction for Palmprint Recognition

    NASA Astrophysics Data System (ADS)

    Choge, H. Kipsang; Karungaru, Stephen G.; Tsuge, Satoru; Fukumi, Minoru

    Over the last quarter century, research in biometric systems has developed at a breathtaking pace and what started with the focus on the fingerprint has now expanded to include face, voice, iris, and behavioral characteristics such as gait. Palmprint is one of the most recent additions, and is currently the subject of great research interest due to its inherent uniqueness, stability, user-friendliness and ease of acquisition. This paper describes an effective and procedurally simple method of palmprint feature extraction specifically for palmprint recognition, although verification experiments are also conducted. This method takes advantage of the correspondences that exist between prominent palmprint features or objects in the spatial domain with those in the frequency or Fourier domain. Multi-dimensional feature vectors are formed by extracting a GA-optimized set of points from the 2-D Fourier spectrum of the palmprint images. The feature vectors are then used for palmprint recognition, before and after dimensionality reduction via the Karhunen-Loeve Transform (KLT). Experiments performed using palmprint images from the ‘PolyU Palmprint Database’ indicate that using a compact set of DFT coefficients, combined with KLT and data preprocessing, produces a recognition accuracy of more than 98% and can provide a fast and effective technique for personal identification.

  9. On a methodology for robust segmentation of nonideal iris images.

    PubMed

    Schmid, Natalia A; Zuo, Jinyu

    2010-06-01

    Iris biometric is one of the most reliable biometrics with respect to performance. However, this reliability is a function of the ideality of the data. One of the most important steps in processing nonideal data is reliable and precise segmentation of the iris pattern from remaining background. In this paper, a segmentation methodology that aims at compensating various nonidealities contained in iris images during segmentation is proposed. The virtue of this methodology lies in its capability to reliably segment nonideal imagery that is simultaneously affected with such factors as specular reflection, blur, lighting variation, occlusion, and off-angle images. We demonstrate the robustness of our segmentation methodology by evaluating ideal and nonideal data sets, namely, the Chinese Academy of Sciences iris data version 3 interval subdirectory, the iris challenge evaluation data, the West Virginia University (WVU) data, and the WVU off-angle data. Furthermore, we compare our performance to that of our implementation of Camus and Wildes's algorithm and Masek's algorithm. We demonstrate considerable improvement in segmentation performance over the formerly mentioned algorithms.

  10. Eclipse-Free-Time Assessment Tool for IRIS

    NASA Technical Reports Server (NTRS)

    Eagle, David

    2012-01-01

    IRIS_EFT is a scientific simulation that can be used to perform an Eclipse-Free- Time (EFT) assessment of IRIS (Infrared Imaging Surveyor) mission orbits. EFT is defined to be those time intervals longer than one day during which the IRIS spacecraft is not in the Earth s shadow. Program IRIS_EFT implements a special perturbation of orbital motion to numerically integrate Cowell's form of the system of differential equations. Shadow conditions are predicted by embedding this integrator within Brent s method for finding the root of a nonlinear equation. The IRIS_EFT software models the effects of the following types of orbit perturbations on the long-term evolution and shadow characteristics of IRIS mission orbits. (1) Non-spherical Earth gravity, (2) Atmospheric drag, (3) Point-mass gravity of the Sun, and (4) Point-mass gravity of the Moon. The objective of this effort was to create an in-house computer program that would perform eclipse-free-time analysis. of candidate IRIS spacecraft mission orbits in an accurate and timely fashion. The software is a suite of Fortran subroutines and data files organized as a "computational" engine that is used to accurately predict the long-term orbit evolution of IRIS mission orbits while searching for Earth shadow conditions.

  11. Effect of iris registration on outcomes of FEMTOLASIK for myopia and myopic astigmatism.

    PubMed

    Ghoreishi, Mohammad; Beni, Zahra Naderi; Beni, Afsaneh Naderi; Kianersi, Farzan

    2017-09-05

    To compare the visual and refractive outcomes after FEMTOLASIK with and without iris registration. In this randomized, prospective, comparative, contralateral eye study, 118 eyes of 59 patients with myopia and myopic astigmatism underwent LASIK using the Femto LDV femtosecond laser (160 µm) and the MEL80 with or without iris registration. For each patient, iris registration FEMTOLASIK was performed on one eye and non-iris registration FEMTOLASIK was performed on the other eye, assigned at random. Patients were evaluated before and 12 months. Uncorrected visual acuity, best-corrected visual acuity, manifest refraction, contrast sensitivity, and higher-order aberrations (HOAs) were evaluated. At 12 months, the mean UDVA was 0.002 ± 0.07 logMAR (20/19) in iris registration eyes and 0.00 ± 0.06 logMAR (20/24) in non-iris registration eyes (P = 0.9). 61% of iris registration eyes and 71.2% of non-iris registration eyes achieved a UDVA of 20/20 or better (P = 0.31); 98.3% of eyes with the iris registration FEMTOLASIK and 94.9% with the non-iris registration FEMTOLASIK were within ±0.50 D from emmetropia (P = 0.71). No statistically significant difference was found in postoperative contrast sensitivity between groups at 3, 6, 12, or 18 cycles/degree (P > 0.05). There was significant increase in total HOA root mean square in two groups. The mean error magnitude of surgically induced astigmatism 12 months postoperatively was -0.33 in iris registration eyes and -0.24 in the non-iris registration eyes (P = 0.36). FEMTOLASIK with and without iris registration provides similar results in myopic and myopic astigmatism patients.

  12. The Validity of the Instructional Reading Level.

    ERIC Educational Resources Information Center

    Powell, William R.

    Presented is a critical inquiry about the product of the informal reading inventory (IRI) and about some of the elements used in the process of determining that product. Recent developments on this topic are briefly reviewed. Questions are raised concerning what is a suitable criterion level for word recognition. The original criterion of 95…

  13. Development of IR imaging system simulator

    NASA Astrophysics Data System (ADS)

    Xiang, Xinglang; He, Guojing; Dong, Weike; Dong, Lu

    2017-02-01

    To overcome the disadvantages of the tradition semi-physical simulation and injection simulation equipment in the performance evaluation of the infrared imaging system (IRIS), a low-cost and reconfigurable IRIS simulator, which can simulate the realistic physical process of infrared imaging, is proposed to test and evaluate the performance of the IRIS. According to the theoretical simulation framework and the theoretical models of the IRIS, the architecture of the IRIS simulator is constructed. The 3D scenes are generated and the infrared atmospheric transmission effects are simulated using OGRE technology in real-time on the computer. The physical effects of the IRIS are classified as the signal response characteristic, modulation transfer characteristic and noise characteristic, and they are simulated on the single-board signal processing platform based on the core processor FPGA in real-time using high-speed parallel computation method.

  14. Automatic Classification of Station Quality by Image Based Pattern Recognition of Ppsd Plots

    NASA Astrophysics Data System (ADS)

    Weber, B.; Herrnkind, S.

    2017-12-01

    The number of seismic stations is growing and it became common practice to share station waveform data in real-time with the main data centers as IRIS, GEOFON, ORFEUS and RESIF. This made analyzing station performance of increasing importance for automatic real-time processing and station selection. The value of a station depends on different factors as quality and quantity of the data, location of the site and general station density in the surrounding area and finally the type of application it can be used for. The approach described by McNamara and Boaz (2006) became standard in the last decade. It incorporates a probability density function (PDF) to display the distribution of seismic power spectral density (PSD). The low noise model (LNM) and high noise model (HNM) introduced by Peterson (1993) are also displayed in the PPSD plots introduced by McNamara and Boaz allowing an estimation of the station quality. Here we describe how we established an automatic station quality classification module using image based pattern recognition on PPSD plots. The plots were split into 4 bands: short-period characteristics (0.1-0.8 s), body wave characteristics (0.8-5 s), microseismic characteristics (5-12 s) and long-period characteristics (12-100 s). The module sqeval connects to a SeedLink server, checks available stations, requests PPSD plots through the Mustang service from IRIS or PQLX/SQLX or from GIS (gempa Image Server), a module to generate different kind of images as trace plots, map plots, helicorder plots or PPSD plots. It compares the image based quality patterns for the different period bands with the retrieved PPSD plot. The quality of a station is divided into 5 classes for each of the 4 bands. Classes A, B, C, D define regular quality between LNM and HNM while the fifth class represents out of order stations with gain problems, missing data etc. Over all period bands about 100 different patterns are required to classify most of the stations available on the IRIS server. The results are written to a file and stations can be filtered by quality. AAAA represents the best quality in all 4 bands. Also a differentiation between instrument types as broad band and short period stations is possible. A regular check using the IRIS SeedLink and Mustang service allow users to be informed about new stations with a specific quality.

  15. Evaluation of treatment in the Smart Home IRIS in terms of functional independence and occupational performance and satisfaction.

    PubMed

    Ocepek, Julija; Roberts, Anne E K; Vidmar, Gaj

    2013-01-01

    The development of assistive technologies, home modifications, and smart homes has rapidly advanced in the last two decades. Health professionals have recognised the benefits of these technologies in improving individual's quality of life. The Smart Home IRIS was established in 2008 within the University Rehabilitation Institute in Ljubljana with the aim to enable persons with disabilities and elderly people to test various assistive technologies and technical solutions for their independent living. We investigated the effect of treatments in the Smart Home IRIS. A convenience sample of 59 persons with disabilities and elderly people (aged 24-81 years) who were treated in the Smart Home IRIS from April to December 2011 participated. Standardised instruments--the Canadian Occupational Performance Measure (COPM) and the Functional Independence Measure (FIM)--were administered at the first assessment in the Smart Home IRIS and at a second assessment at the participant's home after 6-12 months. All the outcomes statistically significantly improved from the first to the second assessment. The treatments in the Smart Home IRIS appeared to contribute to higher occupational performance and satisfaction with performance and higher functional independence of persons with disabilities and elderly people.

  16. Evaluation of Treatment in the Smart Home IRIS in terms of Functional Independence and Occupational Performance and Satisfaction

    PubMed Central

    Ocepek, Julija; Roberts, Anne E. K.; Vidmar, Gaj

    2013-01-01

    The development of assistive technologies, home modifications, and smart homes has rapidly advanced in the last two decades. Health professionals have recognised the benefits of these technologies in improving individual's quality of life. The Smart Home IRIS was established in 2008 within the University Rehabilitation Institute in Ljubljana with the aim to enable persons with disabilities and elderly people to test various assistive technologies and technical solutions for their independent living. We investigated the effect of treatments in the Smart Home IRIS. A convenience sample of 59 persons with disabilities and elderly people (aged 24–81 years) who were treated in the Smart Home IRIS from April to December 2011 participated. Standardised instruments—the Canadian Occupational Performance Measure (COPM) and the Functional Independence Measure (FIM)—were administered at the first assessment in the Smart Home IRIS and at a second assessment at the participant's home after 6–12 months. All the outcomes statistically significantly improved from the first to the second assessment. The treatments in the Smart Home IRIS appeared to contribute to higher occupational performance and satisfaction with performance and higher functional independence of persons with disabilities and elderly people. PMID:24348748

  17. Adaptive fuzzy leader clustering of complex data sets in pattern recognition

    NASA Technical Reports Server (NTRS)

    Newton, Scott C.; Pemmaraju, Surya; Mitra, Sunanda

    1992-01-01

    A modular, unsupervised neural network architecture for clustering and classification of complex data sets is presented. The adaptive fuzzy leader clustering (AFLC) architecture is a hybrid neural-fuzzy system that learns on-line in a stable and efficient manner. The initial classification is performed in two stages: a simple competitive stage and a distance metric comparison stage. The cluster prototypes are then incrementally updated by relocating the centroid positions from fuzzy C-means system equations for the centroids and the membership values. The AFLC algorithm is applied to the Anderson Iris data and laser-luminescent fingerprint image data. It is concluded that the AFLC algorithm successfully classifies features extracted from real data, discrete or continuous.

  18. Log-Gabor Weber descriptor for face recognition

    NASA Astrophysics Data System (ADS)

    Li, Jing; Sang, Nong; Gao, Changxin

    2015-09-01

    The Log-Gabor transform, which is suitable for analyzing gradually changing data such as in iris and face images, has been widely used in image processing, pattern recognition, and computer vision. In most cases, only the magnitude or phase information of the Log-Gabor transform is considered. However, the complementary effect taken by combining magnitude and phase information simultaneously for an image-feature extraction problem has not been systematically explored in the existing works. We propose a local image descriptor for face recognition, called Log-Gabor Weber descriptor (LGWD). The novelty of our LGWD is twofold: (1) to fully utilize the information from the magnitude or phase feature of multiscale and orientation Log-Gabor transform, we apply the Weber local binary pattern operator to each transform response. (2) The encoded Log-Gabor magnitude and phase information are fused at the feature level by utilizing kernel canonical correlation analysis strategy, considering that feature level information fusion is effective when the modalities are correlated. Experimental results on the AR, Extended Yale B, and UMIST face databases, compared with those available from recent experiments reported in the literature, show that our descriptor yields a better performance than state-of-the art methods.

  19. Iris indexing based on local intensity order pattern

    NASA Astrophysics Data System (ADS)

    Emerich, Simina; Malutan, Raul; Crisan, Septimiu; Lefkovits, Laszlo

    2017-03-01

    In recent years, iris biometric systems have increased in popularity and have been proven that are capable of handling large-scale databases. The main advantage of these systems is accuracy and reliability. A proper iris patterns classification is expected to reduce the matching time in huge databases. This paper presents an iris indexing technique based on Local Intensity Order Pattern. The performance of the present approach is evaluated on UPOL database and is compared with other recent systems designed for iris indexing. The results illustrate the potential of the proposed method for large scale iris identification.

  20. Performance in multiple domains of social cognition in parents of patients with schizophrenia.

    PubMed

    Lavoie, Marie-Audrey; Plana, India; Jackson, Philip L; Godmaire-Duhaime, Florence; Bédard Lacroix, Jacinthe; Achim, Amélie M

    2014-12-15

    Social cognition refers to a set of cognitive abilities that allow us to perceive and interpret social stimuli. Social cognition is affected in schizophrenia and impairments have also been documented in unaffected relatives, suggesting that social cognition may be related to a genetic vulnerability to the disease. This study aims to investigate potential impairments in four domains of social cognition (mentalizing, emotion recognition, social knowledge and empathy) in the same group of relatives in order to gather a more complete picture of social cognition difficulties in this population. The Batterie Intégrée de Cognition Sociale (BICS) (mentalizing, emotion recognition, and social knowledge) and the Interpersonal Reactivity Index (IRI) (empathy) were administered to 31 parents of patients with a psychotic disorder and 38 healthy controls. Parents of patients performed significantly worse than controls on the mentalizing test but significantly better on the social knowledge test. No significant between-group differences were observed for emotion recognition and empathy. This study is the first to evaluate four social cognition domains in this population. The results precise which social cognition processes may be impaired or preserved in unaffected relatives of patients and lead us to propose an hypothesis about a mechanism that could underlie the mentalizing difficulties observed in this population. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing

    DOT National Transportation Integrated Search

    2011-12-31

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  2. AHMCT Intelligent Roadway Information System (IRIS) technical support and testing.

    DOT National Transportation Integrated Search

    2011-12-01

    This report documents the research project AHMCT IRIS Technical Support and Testing, : performed under contract 65A0275, Task ID 1777. It presents an overview of the Intelligent : Roadway Information System (IRIS), and its design and function. ...

  3. Alexithymia, empathy, emotion identification and social inference in anorexia nervosa: A case-control study.

    PubMed

    Gramaglia, Carla; Ressico, Francesca; Gambaro, Eleonora; Palazzolo, Anna; Mazzarino, Massimiliano; Bert, Fabrizio; Siliquini, Roberta; Zeppegno, Patrizia

    2016-08-01

    Alexithymia, difficulties in facial emotion recognition, poor socio-relational skills are typical of anorexia nervosa (AN). We assessed patients with AN and healthy controls (HCs) with mixed stimuli: questionnaires (Toronto Alexithymia Scale-TAS, Interpersonal Reactivity Index-IRI), photographs (Facial Emotion Identification Test-FEIT) and dynamic images (The Awareness of Social Inference Test-TASIT). TAS and IRI Personal Distress (PD) were higher in AN than HCs. Few or no differences emerged at the FEIT and TASIT, respectively. Larger effect sizes were found for the TAS results. Despite higher levels of alexithymia, patients with AN seem to properly acknowledge others' emotions while being inhibited in the expression of their own. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Comparison of GPS TEC variations with Holt-Winter method and IRI-2012 over Langkawi, Malaysia

    NASA Astrophysics Data System (ADS)

    Elmunim, N. A.; Abdullah, M.; Hasbi, A. M.; Bahari, S. A.

    2017-07-01

    The Total Electron Content (TEC) is the ionospheric parameter that has the main effect on radio wave propagation. Therefore, it is crucial to evaluate the performance of the TEC models for the further improvement of the ionospheric modelling in equatorial regions. This work presents an analysis of the TEC, derived from the GPS Ionospheric Scintillation and TEC Monitor (GISTM) receiver at the Langkawi station, Malaysia, located at the geographic coordinates of 6.19°N, 99.51°E and the geomagnetic coordinates of 3.39°S, 172.42°E. The diurnal, monthly and seasonal variations in 2014 of the observed GPS-TEC were compared with the statistical Holt-Winter method and a recent version of the International Reference Ionosphere model (IRI-2012), using three different topside options of an electron density, which are the IRI-2001, IRI01-corr and NeQuick. The maximum peaks of the GPS-TEC were observed in the post-noon time and the minimum was observed during the early morning time. In addition, in monthly variations the Holt-Winter and the IRI-2012 topside options showed an underestimation that was in agreement with the GPS-TEC, except for the IRI-2001 model which showed an overestimation in June, July and August. Regarding the seasonal variation of the GPS-TEC, the lowest values were observed during summer and it reached its maximum value during the equinox season. The IRI-2001 showed the highest value of percentage deviation compared to the IRI01-corr, NeQuick and Holt-Winter method. Therefore, the accuracy of the models was found to be approximately 95% in the Holt-Winter method, 75% in the IRI01-corr, 73% in the NeQuick and 66% in the IRI-2001 model. Hence, it can be inferred that the Holt-Winter method showed a higher performance and better estimates of the TEC compared to the IRI01-corr and NeQuick, while the IRI-2001 showed a poor predictive performance in the equatorial region over Malaysia.

  5. Real time biometric surveillance with gait recognition

    NASA Astrophysics Data System (ADS)

    Mohapatra, Subasish; Swain, Anisha; Das, Manaswini; Mohanty, Subhadarshini

    2018-04-01

    Bio metric surveillance has become indispensable for every system in the recent years. The contribution of bio metric authentication, identification, and screening purposes are widely used in various domains for preventing unauthorized access. A large amount of data needs to be updated, segregated and safeguarded from malicious software and misuse. Bio metrics is the intrinsic characteristics of each individual. Recently fingerprints, iris, passwords, unique keys, and cards are commonly used for authentication purposes. These methods have various issues related to security and confidentiality. These systems are not yet automated to provide the safety and security. The gait recognition system is the alternative for overcoming the drawbacks of the recent bio metric based authentication systems. Gait recognition is newer as it hasn't been implemented in the real-world scenario so far. This is an un-intrusive system that requires no knowledge or co-operation of the subject. Gait is a unique behavioral characteristic of every human being which is hard to imitate. The walking style of an individual teamed with the orientation of joints in the skeletal structure and inclinations between them imparts the unique characteristic. A person can alter one's own external appearance but not skeletal structure. These are real-time, automatic systems that can even process low-resolution images and video frames. In this paper, we have proposed a gait recognition system and compared the performance with conventional bio metric identification systems.

  6. Assessment of the NeQuick-2 and IRI-Plas 2017 models using global and long-term GNSS measurements

    NASA Astrophysics Data System (ADS)

    Okoh, Daniel; Onwuneme, Sylvester; Seemala, Gopi; Jin, Shuanggen; Rabiu, Babatunde; Nava, Bruno; Uwamahoro, Jean

    2018-05-01

    The global ionospheric models NeQuick and IRI-Plas have been widely used. However, their uncertainties are not clear at global scale and long term. In this paper, a climatologic assessment of the NeQuick and IRI-Plas models is investigated at a global scale from global navigation satellite system (GNSS) observations. GNSS observations from 36 globally distributed locations were used to evaluate performances of both NeQuick-2 and IRI-Plas 2017 models from January 2006 to July 2017, covering more than the 11-year period of a solar cycle. An hourly interval of diurnal profiles computed on monthly basis was used to measure deviations of the model estimations from corresponding GNSS VTEC observations. Results show that both models are fairly accurate in trends with the GNSS measurements. The NeQuick predictions were generally better than the IRI-Plas predictions in most of the stations and the times. The mean annual prediction errors for the IRI-Plas model typically varied from about 3 TECU at the high latitude stations to about 12 TECU at the low latitude stations, while for the NeQuick the values are respectively about 2-7 TECU. Out of a total 4497 months in which GNSS data were available for all the stations put together for the entire period covered in this work, the NeQuick model was observed to perform better in about 83% of the months while the IRI-Plas performed better in about 17% of the months. The IRI-Plas generally performed better than the NeQuick at certain locations (e.g. DAV1, KERG, and ADIS). For both models, the most of the deviations were witnessed during local daytimes and during seasons that receive maximum solar radiation for various locations. In particular, the IRI-Plas model predictions were improved during periods of increased solar activity at the low latitude stations. The IRI-Plas model overestimates the GNSS VTEC values, except during high solar activity years at some high latitude stations. The NeQuick underestimates the TEC values during the high solar activity years and overestimates it during local daytime for low and moderate solar activity years, but not as much as the IRI-Plas does.

  7. SOME DIFFERENCES BETWEEN SILENT AND ORAL READING RESPONSES ON A STANDARDIZED READING TEST.

    ERIC Educational Resources Information Center

    LEIBERT, ROBERT E.

    A STUDY DESIGNED TO IDENTIFY SOME OF THE DIFFERENCES BETWEEN THE RESPONSES ON THE GATES ADVANCED PRIMARY READING TEST AND THE KINDS OF RESPONSES OBTAINED FROM AN INFORMAL READING INVENTORY (IRI) IS REPORTED. SUBJECTS WERE 65 THIRD-GRADE PUPILS IN WEST BABYLON, NEW YORK. PUPILS AT THE SAME INSTRUCTIONAL LEVEL SCORED HIGHER IN THE RECOGNITION TEST…

  8. Optical Coherence Tomography Angiography Features of Iris Racemose Hemangioma in 4 Cases.

    PubMed

    Chien, Jason L; Sioufi, Kareem; Ferenczy, Sandor; Say, Emil Anthony T; Shields, Carol L

    2017-10-01

    Optical coherence tomography angiography (OCTA) allows visualization of iris racemose hemangioma course and its relation to the normal iris microvasculature. To describe OCTA features of iris racemose hemangioma. Descriptive, noncomparative case series at a tertiary referral center (Ocular Oncology Service of Wills Eye Hospital). Patients diagnosed with unilateral iris racemose hemangioma were included in the study. Features of iris racemose hemangioma on OCTA. Four eyes of 4 patients with unilateral iris racemose hemangioma were included in the study. Mean patient age was 50 years, all patients were white, and Snellen visual acuity was 20/20 in each case. All eyes had sectoral iris racemose hemangioma without associated iris or ciliary body solid tumor on clinical examination and ultrasound biomicroscopy. By anterior segment OCT, the racemose hemangioma was partially visualized in all cases. By OCTA, the hemangioma was clearly visualized as a uniform large-caliber vascular tortuous loop with intense flow characteristics superimposed over small-caliber radial iris vessels against a background of low-signal iris stroma. The vascular course on OCTA resembled a light bulb filament (filament sign), arising from the peripheral iris (base of light bulb) and forming a tortuous loop on reaching its peak (midfilament) near the pupil (n = 3) or midzonal iris (n = 1), before returning to the peripheral iris (base of light bulb). Intravenous fluorescein angiography performed in 1 eye depicted the iris hemangioma; however, small-caliber radial iris vessels were more distinct on OCTA than intravenous fluorescein angiography. Optical coherence tomography angiography is a noninvasive vascular imaging modality that clearly depicts the looping course of iris racemose hemangioma. Optical coherence tomography angiography depicted fine details of radial iris vessels, not distinct on intravenous fluorescein angiography.

  9. PROTECTIVE EFFECT OF IRIS GERMANICA L. IN Β-AMYLOID-INDUCED ANIMAL MODEL OF ALZHEIMER'S DISEASE.

    PubMed

    Borhani, Mona; Sharifzadeh, Mohammad; Farzaei, Mohammad Hosein; Narimani, Zahra; Sabbaghziarani, Fatemeh; Gholami, Mahdi; Rahimi, Roja

    2017-01-01

    Alzheimer's disease (AD) is the most common cause of dementia that is an irretrievable chronic neurodegenerative disease. In the current study, we have examined the therapeutic effects of Iris germanica extract on Amyloid β (Aβ) induced memory impairment. Wistar rats were divided into five groups of 8 per each. Groups were as followed: control group which were normal rats without induction of AD, Aβ group which received Aβ (50 ng/side), iris 100 group which received Aβ + Iris (100 mg/kg), iris 200 group which received Aβ + Iris (200 mg/kg), and iris 400 group which received Aβ + Iris (400 mg/kg). AD was established by intrahippocampal injection of 50 ng/μl/side Aβ1-42. The day after surgery, animals in treatment groups received different doses of the aqueous extract of Iris by gavage for 30 days. Morris water maze test (MWM) was performed to assess the effects of I. germanica on learning and memory of rats with Aβ induced AD. Data from MWM tests, including escape latency and traveled distance, demonstrated that I. germanica extract could markedly improve spatial memory in comparison to control. Moreover, the plant had a significantly better effect on the performance of AD rats in the probe test. I. germanica extract can successfully reverse spatial learning dysfunction in an experimental model of AD. Further neuro psyco-pharmacological studies are mandatory to reveal the mechanism of action of this natural remedy in the management of AD symptoms.

  10. Relationship of the Van Herick Grading System with Peripheral Iris Configuration and Level of Iris Insertion.

    PubMed

    Khan, Faisal Aziz; Niazi, Shafaq Pervez Khan; Khan, Assad Zaman

    2017-09-01

    To determine the relationship of the van Herick angle grading system with the level of iris insertion and peripheral iris configuration. Observational study. Eye department, Combined Military Hospital, Malir Cantt., Karachi, from May to October 2015. Sixty-five eyes of 65 patients were recruited. Anterior chamber depth at the temporal limbus was measured as a fraction of corneal section thickness using van Herick technique and graded on the standard 4-point scale of the van Herick grading system. Gonioscopy of the temporal quadrant was performed with a Posner 4 mirror goniolens and both the true level of iris insertion and peripheral iris configuration were recorded on a 4-point scale so as to equate with the van Herick 4-point grading system. Spearman's rho test was applied to determine the relationship of the van Herick grading system with level of iris root insertion and peripheral iris configuration. Amoderate positive correlation between van Herick grade and peripheral iris configuration was found which was statistically significant (rs=0.42, p < 0.001). Astatistically significant and moderate positive correlation was also detected between van Herick grade and the level of iris insertion (rs=0.45, p < 0.001). The van Herick grade has a moderately positive relationship with the peripheral iris configuration and true level of iris insertion.

  11. Iris concavity, corneal biomechanics, and their correlations with ocular biometry in a cohort of 10- to 12-year-old UK school boys: baseline data.

    PubMed

    Shah, Ameet; Low, Sancy; Garway-Heath, David F; Foster, Paul J; Barton, Keith

    2014-04-17

    Pigment dispersion syndrome is associated with iris concavity. This study investigated the prevalence of iris concavity, defined as a measurement of ≤-0.1 mm, in a cohort of 10- to 12-year-old boys, and explored the relationship between iris curvature and anterior segment biometry. Associations with corneal biomechanical parameters also were explored. A cohort of school boys (n = 96) was recruited from a local school. Anterior segment optical coherence tomography (AS-OCT) was performed under accommodative and nonaccommodative conditions, and iris curvature quantified. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with the ocular response analyzer (ORA). Noncontact axial biometry was performed using laser interferometry. The prevalence of iris concavity was 24% on distance fixation, increasing to 65% on accommodation. Variables significantly associated with nonaccommodating iris curvature were lens vault (P = 0.02) and mean keratometry (P = 0.02). For both variables acting jointly, R(2) = 0.30. Variables associated significantly with accommodating iris curvature were anterior chamber depth (P = 0.009), lens vault (P = 0.049), and mean scleral spur angle (P < 0.0001). For these three variables acting jointly, R(2) = 0.33. Significant association was found between CH and spur-to-spur distance (R(2) = 0.07, P = 0.025). Iris concavity was a common finding in this cohort and related to anterior segment biometric parameters. Further work is required to clarify whether anatomical differences exist between iris concavity seen in the adolescent eye and that found in adults with pigment dispersion syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  12. 78 FR 49486 - Agency Information Collection Activities; Submission to the Office of Management and Budget for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... International Resource Information System (IRIS) AGENCY: Office of Postsecondary Education (OPE), Department of... Resource Information System (IRIS). OMB Control Number: 1840-0759. Type of Review: Revision of an existing... Information System (IRIS) that IFLE uses to collect annual performance reports from Title VI and Fulbright...

  13. [Implantation of an Artificial Iris in 11 Patients].

    PubMed

    Kniestedt, C; Eberhard, R; Fleischhauer, J

    2016-04-01

    Background. Iris defects are mostly acquired after injury, or may be iatrogenic after surgical excision of iris tumours or the result of collateral trauma after anterior segment surgery. They cause severe visual disability, e.g. glare, loss of contrast sensitivity, and loss of best corrected visual acuity. The foldable Koch iris prosthesis has a customised iris design and may be used to reconstruct the anterior segment in patients with partial or complete aniridia. History and Signs. We present the surgical management and clinical course of 6 patients with traumatic iris defects, together with 3 patients with partial aniridia after cataract surgery. Cataract surgery and implantation of an artificial iris were performed in 2 female patients (3 eyes) with congenital aniridia syndrome. Therapy and Outcome. No patient exhibited complications in the postoperative course, with the exception of various intraocular pressure peaks due to secondary glaucoma, that were all corrected by medication to lower topical pressure. Conclusions. In patients with major iris defects, the artificial iris allows functionally and aesthetically satisfactory reconstruction of the anterior segment. Georg Thieme Verlag KG Stuttgart · New York.

  14. A novel in vivo model of puncture-induced iris neovascularization.

    PubMed

    Beaujean, Ophélie; Locri, Filippo; Aronsson, Monica; Kvanta, Anders; André, Helder

    2017-01-01

    To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances.

  15. Adaptive weighted local textural features for illumination, expression, and occlusion invariant face recognition

    NASA Astrophysics Data System (ADS)

    Cui, Chen; Asari, Vijayan K.

    2014-03-01

    Biometric features such as fingerprints, iris patterns, and face features help to identify people and restrict access to secure areas by performing advanced pattern analysis and matching. Face recognition is one of the most promising biometric methodologies for human identification in a non-cooperative security environment. However, the recognition results obtained by face recognition systems are a affected by several variations that may happen to the patterns in an unrestricted environment. As a result, several algorithms have been developed for extracting different facial features for face recognition. Due to the various possible challenges of data captured at different lighting conditions, viewing angles, facial expressions, and partial occlusions in natural environmental conditions, automatic facial recognition still remains as a difficult issue that needs to be resolved. In this paper, we propose a novel approach to tackling some of these issues by analyzing the local textural descriptions for facial feature representation. The textural information is extracted by an enhanced local binary pattern (ELBP) description of all the local regions of the face. The relationship of each pixel with respect to its neighborhood is extracted and employed to calculate the new representation. ELBP reconstructs a much better textural feature extraction vector from an original gray level image in different lighting conditions. The dimensionality of the texture image is reduced by principal component analysis performed on each local face region. Each low dimensional vector representing a local region is now weighted based on the significance of the sub-region. The weight of each sub-region is determined by employing the local variance estimate of the respective region, which represents the significance of the region. The final facial textural feature vector is obtained by concatenating the reduced dimensional weight sets of all the modules (sub-regions) of the face image. Experiments conducted on various popular face databases show promising performance of the proposed algorithm in varying lighting, expression, and partial occlusion conditions. Four databases were used for testing the performance of the proposed system: Yale Face database, Extended Yale Face database B, Japanese Female Facial Expression database, and CMU AMP Facial Expression database. The experimental results in all four databases show the effectiveness of the proposed system. Also, the computation cost is lower because of the simplified calculation steps. Research work is progressing to investigate the effectiveness of the proposed face recognition method on pose-varying conditions as well. It is envisaged that a multilane approach of trained frameworks at different pose bins and an appropriate voting strategy would lead to a good recognition rate in such situation.

  16. IRIS thermal balance test within ESTEC LSS

    NASA Technical Reports Server (NTRS)

    Messidoro, Piero; Ballesio, Marino; Vessaz, J. P.

    1988-01-01

    The Italian Research Interim Stage (IRIS) thermal balance test was successfully performed in the ESTEC Large Space Simulator (LSS) to qualify the thermal design and to validate the thermal mathematical model. Characteristics of the test were the complexity of the set-up required to simulate the Shuttle cargo bay and allowing IRIS mechanism actioning and operation for the first time in the new LSS facility. Details of the test are presented, and test results for IRIS and the LSS facility are described.

  17. Role of LTA4H Polymorphism in Tuberculosis-Associated Immune Reconstitution Inflammatory Syndrome Occurrence and Clinical Severity in Patients Infected with HIV.

    PubMed

    Narendran, Gopalan; Kavitha, Dhanasekaran; Karunaianantham, Ramesh; Gil-Santana, Leonardo; Almeida-Junior, Jilson L; Reddy, Sirasanambatti Devarajulu; Kumar, Marimuthu Makesh; Hemalatha, Haribabu; Jayanthi, Nagesh Nalini; Ravichandran, Narayanan; Krishnaraja, Raja; Prabhakar, Angamuthu; Manoharan, Tamizhselvan; Nithyananthan, Lokeswaran; Arjunan, Gunasundari; Natrajan, Mohan; Swaminathan, Soumya; Andrade, Bruno B

    2016-01-01

    Paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory phenomenon complicating HIV management in coincidental tuberculosis (TB) infection, upon immune reconstitution driven by antiretroviral therapy (ART). Leukotriene A4 hydroxylase (LTA4H), an enzyme which converts LTA4 to LTB4, regulates the balance between the anti-inflammatory lipoxins and pro-inflammatory LTB4, with direct implications in TB-driven inflammation. In humans, a single nucleotide polymorphism (SNP) in the LTA4H promoter which regulates its transcriptional activity (rs17525495) has been identified and described to impact clinical severity of TB presentation and response to corticosteroid therapy. Notably, the role of LTA4H on TB-IRIS has not been previously evaluated. Here, we performed an exploratory investigation testing the association of LTA4H polymorphism with respect to frequency of TB-IRIS occurrence and severity of TB-IRIS presentation in HIV-TB co-infected individuals. Genotypic evaluation of the LTA4H enzyme from available samples was retrospectively correlated with clinical data captured in case sheets including IRIS details. The cohort included patients recruited from a prospective cohort study nested within a randomized clinical trial (NCT0933790) of ART-naïve HIV+ patients with newly diagnosed rifampicin sensitive pulmonary TB in South India. Frequency of the wild type genotype (CC), as well as of the mutant genotypes (CT or TT) in the IRIS and non-IRIS patients was estimated. Comparative analyses were performed between wild genotype (CC) and the mutant genotypes (CT or TT) and tested for association between the LTA4H polymorphisms and IRIS incidence and clinical severity. A total of 142 eligible ART-naïve patients were included in the analyses. Eighty-six individuals exhibited the wild genotype (CC) while 56 had mutant genotypes (43-CT and only 13-TT). Variant allele frequency was 0.23 and 0.26 in non-IRIS group and in IRIS group, respectively. Upon ART initiation, 51 patients developed IRIS while 91 did not. IRIS incidence was 34% and 37% in the wild (CC) and mutant type (CT/TT), respectively (p = 0.858) with a higher frequency of severe IRIS presentation in the mutant genotype group compared to the wild type genotype (p = 0.0006). A logistic regression model confirmed the association between the presence of CT/TT genotypes and occurrence of severe IRIS. Corticosteroid therapy successfully resolved IRIS in all cases irrespective of the LTA4H genotype. A higher incidence of severe IRIS among patients with mutant LTA4H genotypes (CT and TT) was observed compared to the wild type, despite similar IRIS incidence and immune restoration in both groups. Steroids were effective in alleviating IRIS in all the genotypes.

  18. Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).

    PubMed

    West, A G; Goldsmith, G R; Matimati, I; Dawson, T E

    2011-08-30

    Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Analysis of physical layer performance of data center with optical wavelength switches based on advanced modulation formats

    NASA Astrophysics Data System (ADS)

    Ahmad, Iftikhar; Chughtai, Mohsan Niaz

    2018-05-01

    In this paper the IRIS (Integrated Router Interconnected spectrally), an optical domain architecture for datacenter network is analyzed. The IRIS integrated with advanced modulation formats (M-QAM) and coherent optical receiver is analyzed. The channel impairments are compensated using the DSP algorithms following the coherent receiver. The proposed scheme allows N2 multiplexed wavelengths for N×N size. The performance of the N×N-IRIS switch with and without wavelength conversion is analyzed for different Baud rates over M-QAM modulation formats. The performance of the system is analyzed in terms of bit error rate (BER) vs OSNR curves.

  20. The Priority of Road Rehabilitation in Karanganyar Regency Using IRI Estimation from Roadroid

    NASA Astrophysics Data System (ADS)

    Achmadi, F.; Suprapto, M.; Setyawan, A.

    2017-02-01

    The IRI (International Roughness Index) is a road roughness index commonly obtained from measured longitudinal road profiles. This is one of the functional performance a surface of road pavement. Therefore, needs to be done evaluation and monitoring periodically to getting priority of road rehabilitation right on target. The IRI standard has commonly been used worldwide for evaluating road system. The Roadroid is an application to measure road quality with a website to view road quality. It is designed for Android smartphones, so we can easily measure and monitor the road and also use the camera for GPS-tagged photo. By using the built-in vibration sensor in smartphones, it is possible to collect IRI value which can be an indicator road conditions. This study attempts to explain the priority of road rehabilitation in Karanganyar Regency. The location of the study focused on a collector street (primary, secondary and locally road). The result of IRI estimation will be combined with other aspects that influences; land use, policy, the connectivity of road and traffic average daily. Based on IRI estimation using Roadroid, the road conditions in Karanganyar Regency can be described 59,60% were good (IRI<4,5) 21,30% fair (4,512).

  1. A novel in vivo model of puncture-induced iris neovascularization

    PubMed Central

    Aronsson, Monica; Kvanta, Anders

    2017-01-01

    Purpose To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Methods Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Results Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. Conclusions This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances. PMID:28658313

  2. Combined iridocyclectomy and lensectomy surgical technique modified for the removal of an iris cyst in a child.

    PubMed

    Farpour, Bijan; Browne, Alison; McClellan, BmedscKathyA; Billson, Frank A

    2002-01-01

    The purpose of this report is to describe a modified surgical iridocyclectomy technique and lensectomy for the removal of a recurrent iris cyst and a cataract in a child. A 3-year-old boy underwent uncomplicated standard iridocyclectomy for the removal of an enlarging congenital epidermal iris cyst. In the postoperative period, the cyst recurred. A second surgical intervention was performed using a modified iridocyclectomy technique. Sclerocorneal dissection of the involved quadrant was performed. After a lensectomy, an additional deep lamellar dissection of the peripheral cornea was undertaken prior to iris cyst removal and pupil reconstruction. This modified two-layered iridocyclectomy technique permits an elegant access to the iris lesion and allows the construction of a two-layered watertight wound, reducing the risk of hypotony and wound ectasia. We believe it also allows a better control of astigmatism and is a safe procedure in the pediatric population, particularly during the amblyogenic period.

  3. Determination of irinotecan and its metabolite SN-38 in dried blood spots using high-performance liquid-chromatography with fluorescence detection.

    PubMed

    Hahn, Roberta Z; Arnhold, Priscila C; Andriguetti, Natália B; Schneider, Anelise; Klück, Helena M; Dos Reis, Simone L; Bastiani, Marcos Frank; Kael, Igor; da Silva, Anne Caroline Cezimbra; Schwartsmann, Gilberto; Antunes, Marina V; Linden, Rafael

    2018-02-20

    Irinotecan (IRI) is an antineoplastic drug widely used for the treatment of colorectal and advanced pancreatic cancer. Despite its clinical utility, the clinical use of IRI is associated with potentially severe hematopoietic and gastrointestinal toxicities. The quantification of IRI and its active metabolite SN-38 in dried blood spots (DBS) may be an alternative to individualize the drug dose through a minimally invasive and easy collection method. The aim of this study was to develop and validate a simple and fast HPLC-FL assay for simultaneous IRI and SN-38 measurement in DBS, with adequate analytical performance for clinical use. The method employs liquid extraction of one 8mm disk of whole blood, followed by separation in a reversed phase Eclipse Plus C8 column (150×4.6mm, 5μm). Detection was performed with a fluorescence detector, with excitation wavelength of 370 and emission of 420 for IRI and 540nm for SN-38 and internal standard (camptothecin). Total analytical run time was 17min. Mobile phase was a mixture of 0.1M phosphate buffer pH 4.0 and acetonitrile (80:20, v/v), at 1mLmin -1 . The assay was linear in the range 10-3,000ngmL -1 and from 0.5 to 300ngmL -1 for IRI and SN-38, respectively. Precision assays presented CV% of 2.71-5.65 and 2.15-10.07 for IRI and SN-38, respectively, and accuracy in the range of 94.26-100.93 and 94.24-99.33%. IRI and SN-38 were stable at 25 and 42°C for 14days in DBS samples. The method was applied to DBS samples obtained from fingerpicks from 19 volunteers receiving IRI in single or combined chemotherapy regimens, collected 1 and 24h after beginning of the infusion. The estimated plasma concentration of IRI and SN-38 in sample collected 1h after star of infusion had 16 of 19 values within the ±20% range of the measured plasma concentrations. On the other hand, predictions of IRI and SN-38 plasma concentrations from DBS measurements obtained 24h after the beginning of the infusion were poor. AUC of IRI that was calculated using plasma and DBS-estimated concentrations, with a high correlation (r=0.918). The method presented suitable characteristics for the clinical use. However, translation of IRI and SN-38 DBS to plasma concentrations is challenging due to the compound's variable plasma/blood partition. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    PubMed

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  5. Joint Sparse Representation for Robust Multimodal Biometrics Recognition

    DTIC Science & Technology

    2012-01-01

    described in III. Experimental evaluations on a comprehensive multimodal dataset and a face database have been described in section V. Finally, in...WVU Multimodal Dataset The WVU multimodal dataset is a comprehensive collection of different biometric modalities such as fingerprint, iris, palmprint ...Martnez and R. Benavente, “The AR face database ,” CVC Technical Report, June 1998. [29] U. Park and A. Jain, “Face matching and retrieval using soft

  6. Joint Sparse Representation for Robust Multimodal Biometrics Recognition

    DTIC Science & Technology

    2014-01-01

    comprehensive multimodal dataset and a face database are described in section V. Finally, in section VI, we discuss the computational complexity of...fingerprint, iris, palmprint , hand geometry and voice from subjects of different age, gender and ethnicity as described in Table I. It is a...Taylor, “Constructing nonlinear discriminants from multiple data views,” Machine Learning and Knowl- edge Discovery in Databases , pp. 328–343, 2010

  7. Integrated Color Coding and Monochrome Multi-Spectral Fusion

    DTIC Science & Technology

    1999-01-01

    Suppl. pg s1002. [Katz 1987 ] Katz et al, "Application of Spectral Filtering to Missile Detection Using Staring Sensors at MWIR Wavelengths...34, Proceedings of the IRIS Conf. on Targets, Backgrounds, and Discrimination, Feb. 1987 [Morrone 1989], Morrone M.C. and D.C.,”Discrimination of spatial phase in...April) 1990, Orlando, FL. [Subramaniam 1997] Subramaniam and Biederman “Effect of Contrast Reversal on Object Recognition (ARVO 1997) Investigative

  8. Image Quality Assessment for Fake Biometric Detection: Application to Iris, Fingerprint, and Face Recognition.

    PubMed

    Galbally, Javier; Marcel, Sébastien; Fierrez, Julian

    2014-02-01

    To ensure the actual presence of a real legitimate trait in contrast to a fake self-manufactured synthetic or reconstructed sample is a significant problem in biometric authentication, which requires the development of new and efficient protection measures. In this paper, we present a novel software-based fake detection method that can be used in multiple biometric systems to detect different types of fraudulent access attempts. The objective of the proposed system is to enhance the security of biometric recognition frameworks, by adding liveness assessment in a fast, user-friendly, and non-intrusive manner, through the use of image quality assessment. The proposed approach presents a very low degree of complexity, which makes it suitable for real-time applications, using 25 general image quality features extracted from one image (i.e., the same acquired for authentication purposes) to distinguish between legitimate and impostor samples. The experimental results, obtained on publicly available data sets of fingerprint, iris, and 2D face, show that the proposed method is highly competitive compared with other state-of-the-art approaches and that the analysis of the general image quality of real biometric samples reveals highly valuable information that may be very efficiently used to discriminate them from fake traits.

  9. Knowing what the brain is seeing in three dimensions: A novel, noninvasive, sensitive, accurate, and low-noise technique for measuring ocular torsion.

    PubMed

    Otero-Millan, Jorge; Roberts, Dale C; Lasker, Adrian; Zee, David S; Kheradmand, Amir

    2015-01-01

    Torsional eye movements are rotations of the eye around the line of sight. Measuring torsion is essential to understanding how the brain controls eye position and how it creates a veridical perception of object orientation in three dimensions. Torsion is also important for diagnosis of many vestibular, neurological, and ophthalmological disorders. Currently, there are multiple devices and methods that produce reliable measurements of horizontal and vertical eye movements. Measuring torsion, however, noninvasively and reliably has been a longstanding challenge, with previous methods lacking real-time capabilities or suffering from intrusive artifacts. We propose a novel method for measuring eye movements in three dimensions using modern computer vision software (OpenCV) and concepts of iris recognition. To measure torsion, we use template matching of the entire iris and automatically account for occlusion of the iris and pupil by the eyelids. The current setup operates binocularly at 100 Hz with noise <0.1° and is accurate within 20° of gaze to the left, to the right, and up and 10° of gaze down. This new method can be widely applicable and fill a gap in many scientific and clinical disciplines.

  10. Knowing what the brain is seeing in three dimensions: A novel, noninvasive, sensitive, accurate, and low-noise technique for measuring ocular torsion

    PubMed Central

    Otero-Millan, Jorge; Roberts, Dale C.; Lasker, Adrian; Zee, David S.; Kheradmand, Amir

    2015-01-01

    Torsional eye movements are rotations of the eye around the line of sight. Measuring torsion is essential to understanding how the brain controls eye position and how it creates a veridical perception of object orientation in three dimensions. Torsion is also important for diagnosis of many vestibular, neurological, and ophthalmological disorders. Currently, there are multiple devices and methods that produce reliable measurements of horizontal and vertical eye movements. Measuring torsion, however, noninvasively and reliably has been a longstanding challenge, with previous methods lacking real-time capabilities or suffering from intrusive artifacts. We propose a novel method for measuring eye movements in three dimensions using modern computer vision software (OpenCV) and concepts of iris recognition. To measure torsion, we use template matching of the entire iris and automatically account for occlusion of the iris and pupil by the eyelids. The current setup operates binocularly at 100 Hz with noise <0.1° and is accurate within 20° of gaze to the left, to the right, and up and 10° of gaze down. This new method can be widely applicable and fill a gap in many scientific and clinical disciplines. PMID:26587699

  11. Role of LTA4H Polymorphism in Tuberculosis-Associated Immune Reconstitution Inflammatory Syndrome Occurrence and Clinical Severity in Patients Infected with HIV

    PubMed Central

    Narendran, Gopalan; Kavitha, Dhanasekaran; Karunaianantham, Ramesh; Gil-Santana, Leonardo; Almeida-Junior, Jilson L.; Reddy, Sirasanambatti Devarajulu; Kumar, Marimuthu Makesh; Hemalatha, Haribabu; Jayanthi, Nagesh Nalini; Ravichandran, Narayanan; Krishnaraja, Raja; Prabhakar, Angamuthu; Manoharan, Tamizhselvan; Nithyananthan, Lokeswaran; Arjunan, Gunasundari; Natrajan, Mohan; Swaminathan, Soumya

    2016-01-01

    Background Paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory phenomenon complicating HIV management in coincidental tuberculosis (TB) infection, upon immune reconstitution driven by antiretroviral therapy (ART). Leukotriene A4 hydroxylase (LTA4H), an enzyme which converts LTA4 to LTB4, regulates the balance between the anti-inflammatory lipoxins and pro-inflammatory LTB4, with direct implications in TB-driven inflammation. In humans, a single nucleotide polymorphism (SNP) in the LTA4H promoter which regulates its transcriptional activity (rs17525495) has been identified and described to impact clinical severity of TB presentation and response to corticosteroid therapy. Notably, the role of LTA4H on TB-IRIS has not been previously evaluated. Here, we performed an exploratory investigation testing the association of LTA4H polymorphism with respect to frequency of TB-IRIS occurrence and severity of TB-IRIS presentation in HIV-TB co-infected individuals. Methods Genotypic evaluation of the LTA4H enzyme from available samples was retrospectively correlated with clinical data captured in case sheets including IRIS details. The cohort included patients recruited from a prospective cohort study nested within a randomized clinical trial (NCT0933790) of ART-naïve HIV+ patients with newly diagnosed rifampicin sensitive pulmonary TB in South India. Frequency of the wild type genotype (CC), as well as of the mutant genotypes (CT or TT) in the IRIS and non-IRIS patients was estimated. Comparative analyses were performed between wild genotype (CC) and the mutant genotypes (CT or TT) and tested for association between the LTA4H polymorphisms and IRIS incidence and clinical severity. Results A total of 142 eligible ART-naïve patients were included in the analyses. Eighty-six individuals exhibited the wild genotype (CC) while 56 had mutant genotypes (43-CT and only 13-TT). Variant allele frequency was 0.23 and 0.26 in non-IRIS group and in IRIS group, respectively. Upon ART initiation, 51 patients developed IRIS while 91 did not. IRIS incidence was 34% and 37% in the wild (CC) and mutant type (CT/TT), respectively (p = 0.858) with a higher frequency of severe IRIS presentation in the mutant genotype group compared to the wild type genotype (p = 0.0006). A logistic regression model confirmed the association between the presence of CT/TT genotypes and occurrence of severe IRIS. Corticosteroid therapy successfully resolved IRIS in all cases irrespective of the LTA4H genotype. Conclusion A higher incidence of severe IRIS among patients with mutant LTA4H genotypes (CT and TT) was observed compared to the wild type, despite similar IRIS incidence and immune restoration in both groups. Steroids were effective in alleviating IRIS in all the genotypes. PMID:27643598

  12. Immune Reconstitution Inflammatory Syndrome Unmasking or Worsening AIDS-Related Progressive Multifocal Leukoencephalopathy: A Literature Review.

    PubMed

    Fournier, Anna; Martin-Blondel, Guillaume; Lechapt-Zalcman, Emmanuèle; Dina, Julia; Kazemi, Apolline; Verdon, Renaud; Mortier, Emmanuel; de La Blanchardière, Arnaud

    2017-01-01

    Incidence of progressive multifocal leukoencephalopathy (PML) in HIV-infected patients has declined in the combined antiretroviral therapy (cART) era although a growing number of acquired immunodeficiency syndrome (AIDS)-related PML-immune reconstitution inflammatory syndromes (PML-IRIS) have been published during the same period. Therapeutic management of PML-IRIS is not consensual and mainly relies on corticosteroids. Our main aim was, in addition to provide a thoughtful analysis of published PML-IRIS cases, to assess the benefit of corticosteroids in the management of PML-IRIS, focusing on confirmed cases. We performed a literature review of the 46 confirmed cases of PML-IRIS cases occurring in HIV-infected patients from 1998 to September 2016 (21 unmasking and 25 paradoxical PML-IRIS). AIDS-related PML-IRIS patients were mostly men (sex ratio 4/1) with a median age of 40.5 years (range 12-66). Median CD4 T cell count before cART and at PML-IRIS onset was 45/μl (0-301) and 101/μl (20-610), respectively. After cART initiation, PML-IRIS occurred within a median timescale of 38 days (18-120). Clinical signs were motor deficits (69%), speech disorders (36%), cognitive disorders (33%), cerebellar ataxia (28%), and visual disturbances (23%). Brain MRI revealed hyperintense areas on T2-weighted sequences and FLAIR images (76%) and suggestive contrast enhancement (87%). PCR for John Cunningham virus (JCV) in cerebrospinal fluid (CSF) was positive in only 84% of cases; however, when performed, brain biopsy confirmed diagnosis of PML in 90% of cases and demonstrated histological signs of IRIS in 95% of cases. Clinical worsening related to PML-IRIS and leading to death was observed in 28% of cases. Corticosteroids were prescribed in 63% of cases and maraviroc in one case. Statistical analysis failed to demonstrate significant benefit from steroid treatment, despite spectacular improvement in certain cases. Diagnosis of PML-IRIS should be considered in HIV-infected patients with worsening neurological symptoms after initiation or resumption of effective cART, independently of CD4 cell count prior to cART. If PCR for JCV is negative in CSF, brain biopsy should be discussed. Only large multicentric randomized trials could potentially demonstrate the possible efficacy of corticosteroids and/or CCR5 antagonists in the management of PML-IRIS.

  13. Immune Reconstitution Inflammatory Syndrome Unmasking or Worsening AIDS-Related Progressive Multifocal Leukoencephalopathy: A Literature Review

    PubMed Central

    Fournier, Anna; Martin-Blondel, Guillaume; Lechapt-Zalcman, Emmanuèle; Dina, Julia; Kazemi, Apolline; Verdon, Renaud; Mortier, Emmanuel; de La Blanchardière, Arnaud

    2017-01-01

    Incidence of progressive multifocal leukoencephalopathy (PML) in HIV-infected patients has declined in the combined antiretroviral therapy (cART) era although a growing number of acquired immunodeficiency syndrome (AIDS)-related PML-immune reconstitution inflammatory syndromes (PML-IRIS) have been published during the same period. Therapeutic management of PML-IRIS is not consensual and mainly relies on corticosteroids. Our main aim was, in addition to provide a thoughtful analysis of published PML-IRIS cases, to assess the benefit of corticosteroids in the management of PML-IRIS, focusing on confirmed cases. We performed a literature review of the 46 confirmed cases of PML-IRIS cases occurring in HIV-infected patients from 1998 to September 2016 (21 unmasking and 25 paradoxical PML-IRIS). AIDS-related PML-IRIS patients were mostly men (sex ratio 4/1) with a median age of 40.5 years (range 12–66). Median CD4 T cell count before cART and at PML-IRIS onset was 45/μl (0–301) and 101/μl (20–610), respectively. After cART initiation, PML-IRIS occurred within a median timescale of 38 days (18–120). Clinical signs were motor deficits (69%), speech disorders (36%), cognitive disorders (33%), cerebellar ataxia (28%), and visual disturbances (23%). Brain MRI revealed hyperintense areas on T2-weighted sequences and FLAIR images (76%) and suggestive contrast enhancement (87%). PCR for John Cunningham virus (JCV) in cerebrospinal fluid (CSF) was positive in only 84% of cases; however, when performed, brain biopsy confirmed diagnosis of PML in 90% of cases and demonstrated histological signs of IRIS in 95% of cases. Clinical worsening related to PML-IRIS and leading to death was observed in 28% of cases. Corticosteroids were prescribed in 63% of cases and maraviroc in one case. Statistical analysis failed to demonstrate significant benefit from steroid treatment, despite spectacular improvement in certain cases. Diagnosis of PML-IRIS should be considered in HIV-infected patients with worsening neurological symptoms after initiation or resumption of effective cART, independently of CD4 cell count prior to cART. If PCR for JCV is negative in CSF, brain biopsy should be discussed. Only large multicentric randomized trials could potentially demonstrate the possible efficacy of corticosteroids and/or CCR5 antagonists in the management of PML-IRIS. PMID:28588577

  14. Comparison of GPS-TEC measurements with NeQuick2 and IRI model predictions in the low latitude East African region during varying solar activity period (1998 and 2008-2015)

    NASA Astrophysics Data System (ADS)

    Mengistu, E.; Damtie, B.; Moldwin, M. B.; Nigussie, M.

    2018-03-01

    This paper examines the performances of NeQuick2, the latest available IRI-2016, IRI-2012 and IRI-2007 models in describing the monthly and seasonal mean total electron content (TEC) over the East African region. This is to gain insight into the success of the various model types and versions at characterizing the ionosphere within the equatorial ionization anomaly. TEC derived from five Global Positioning System (GPS) receivers installed at Addis Ababa (ADD, 5.33°N, 111.99°E Geog.), Asab (ASAB, 8.67°N, 116.44°E Geog.), Ambo (ABOO, 5.43°N, 111.05°E Geog.), Nairobi (RCMN, -4.48°N, 108.46°E Geog.) and Nazret (NAZR, 4.78°N, 112.43°E Geog.), are compared with the corresponding values computed using those models during varying solar activity period (1998 and 2008-2015). We found that different models describe the equatorial and anomaly region ionosphere best depending on solar cycle, season and geomagnetic activity levels. Our results show that IRI-2016 is the best model (compared to others in terms of discrepancy range) in estimating the monthly mean GPS-TEC at NAZR, ADD and RCMN stations except at ADD during 2008 and 2012. It is also found that IRI-2012 is the best model in estimating the monthly mean TEC at ABOO station in 2014. IRI show better agreement with observations during June solstice for all the years studied at ADD except in 2012 where NeQuick2 better performs. At NAZR, NeQuick2 better performs in estimating seasonal mean GPS-TEC during 2011, while IRI models are best during 2008-2009. Both NeQuick2 and IRI models underestimate measured TEC for all the seasons at ADD in 2010 but overestimate at NAZR in 2009 and RCMN in 2008. The periodic variations of experimental and modeled TEC have been compared with solar and geomagnetic indices at ABOO and ASAB in 2014 and results indicate that the F10.7 and sunspot number as indices of solar activity seriously affects the TEC variations with periods of 16-32 days followed by the geomagnetic activity on shorter timescales (roughly periods of less than 16 days). In this case, NeQuick2 derived TEC shows better agreement with a long term period variations of GPS-TEC, while IRI-2016 and IRI-2007 show better agreement with observations during short term periodic variations. This indicates that the dependence of NeQuick2 derived TEC on F10.7 is seasonal. Hence, we suggest that representation of geomagnetic activity indices is required for better performance over the low latitude region.

  15. A hyperspectral imaging system for the evaluation of the human iris spectral reflectance

    NASA Astrophysics Data System (ADS)

    Di Cecilia, Luca; Marazzi, Francesco; Rovati, Luigi

    2017-02-01

    According to previous studies, the measurement of the human iris pigmentation can be exploited to detect certain eye pathological conditions in their early stage. In this paper, we propose an instrument and a method to perform hyperspectral quantitative measurements of the iris spectral reflectance. The system is based on a simple imaging setup, which includes a monochrome camera mounted on a standard ophthalmic microscope movement controller, a monochromator, and a flashing LED-based slit lamp. To assure quantitative measurements, the system is properly calibrated against a NIST reflectance standard. Iris reflectance images can be obtained in the spectral range 495-795 nm with a resolution of 25 nm. Each image consists of 1280 x 1024 pixels having a spatial resolution of 18 μm. Reflectance spectra can be calculated both from discrete areas of the iris and as the average of the whole iris surface. Preliminary results suggest that hyperspectral imaging of the iris can provide much more morphological and spectral information with respect to conventional qualitative colorimetric methods.

  16. Characterization of iris pattern stretches and application to the measurement of roll axis eye movements.

    PubMed

    Nishiyama, Junpei; Hashimoto, Tsutomu; Sakashita, Yusuke; Fujiyoshi, Hironobu; Hirata, Yutaka

    2008-01-01

    Eye movements are utilized in many scientific studies as a probe that reflects the neural representation of 3 dimensional extrapersonal space. This study proposes a method to accurately measure the roll component of eye movements under the conditions in which the pupil diameter changes. Generally, the iris pattern matching between a reference and a test iris image is performed to estimate roll angle of the test image. However, iris patterns are subject to change when the pupil size changes, thus resulting in less accurate roll angle estimation if the pupil sizes in the test and reference images are different. We characterized non-uniform iris pattern contraction/expansion caused by pupil dilation/constriction, and developed an algorithm to convert an iris pattern with an arbitrary pupil size into that with the same pupil size as the reference iris pattern. It was demonstrated that the proposed method improved the accuracy of the measurement of roll eye movement by up to 76.9%.

  17. Latent Ice Recrystallization Inhibition Activity in Nonantifreeze Proteins: Ca2+-Activated Plant Lectins and Cation-Activated Antimicrobial Peptides.

    PubMed

    Mitchell, Daniel E; Gibson, Matthew I

    2015-10-12

    Organisms living in polar regions have evolved a series of antifreeze (glyco) proteins (AFGPs) to enable them to survive by modulating the structure of ice. These proteins have huge potential for use in cellular cryopreservation, ice-resistant surfaces, frozen food, and cryosurgery, but they are limited by their relatively low availability and questions regarding their mode of action. This has triggered the search for biomimetic materials capable of reproducing this function. The identification of new structures and sequences capable of inhibiting ice growth is crucial to aid our understanding of these proteins. Here, we show that plant c-type lectins, which have similar biological function to human c-type lectins (glycan recognition) but no sequence homology to AFPs, display calcium-dependent ice recrystallization inhibition (IRI) activity. This IRI activity can be switched on/off by changing the Ca2+ concentration. To show that more (nonantifreeze) proteins may exist with the potential to display IRI, a second motif was considered, amphipathicity. All known AFPs have defined hydrophobic/hydrophilic domains, rationalizing this choice. The cheap, and widely used, antimicrobial Nisin was found to have cation-dependent IRI activity, controlled by either acid or addition of histidine-binding ions such as zinc or nickel, which promote its amphipathic structure. These results demonstrate a new approach in the identification of antifreeze protein mimetic macromolecules and may help in the development of synthetic mimics of AFPs.

  18. Latent Ice Recrystallization Inhibition Activity in Nonantifreeze Proteins: Ca2+-Activated Plant Lectins and Cation-Activated Antimicrobial Peptides

    PubMed Central

    2015-01-01

    Organisms living in polar regions have evolved a series of antifreeze (glyco) proteins (AFGPs) to enable them to survive by modulating the structure of ice. These proteins have huge potential for use in cellular cryopreservation, ice-resistant surfaces, frozen food, and cryosurgery, but they are limited by their relatively low availability and questions regarding their mode of action. This has triggered the search for biomimetic materials capable of reproducing this function. The identification of new structures and sequences capable of inhibiting ice growth is crucial to aid our understanding of these proteins. Here, we show that plant c-type lectins, which have similar biological function to human c-type lectins (glycan recognition) but no sequence homology to AFPs, display calcium-dependent ice recrystallization inhibition (IRI) activity. This IRI activity can be switched on/off by changing the Ca2+ concentration. To show that more (nonantifreeze) proteins may exist with the potential to display IRI, a second motif was considered, amphipathicity. All known AFPs have defined hydrophobic/hydrophilic domains, rationalizing this choice. The cheap, and widely used, antimicrobial Nisin was found to have cation-dependent IRI activity, controlled by either acid or addition of histidine-binding ions such as zinc or nickel, which promote its amphipathic structure. These results demonstrate a new approach in the identification of antifreeze protein mimetic macromolecules and may help in the development of synthetic mimics of AFPs. PMID:26407233

  19. The Potential of Using Brain Images for Authentication

    PubMed Central

    Zhou, Zongtan; Shen, Hui; Hu, Dewen

    2014-01-01

    Biometric recognition (also known as biometrics) refers to the automated recognition of individuals based on their biological or behavioral traits. Examples of biometric traits include fingerprint, palmprint, iris, and face. The brain is the most important and complex organ in the human body. Can it be used as a biometric trait? In this study, we analyze the uniqueness of the brain and try to use the brain for identity authentication. The proposed brain-based verification system operates in two stages: gray matter extraction and gray matter matching. A modified brain segmentation algorithm is implemented for extracting gray matter from an input brain image. Then, an alignment-based matching algorithm is developed for brain matching. Experimental results on two data sets show that the proposed brain recognition system meets the high accuracy requirement of identity authentication. Though currently the acquisition of the brain is still time consuming and expensive, brain images are highly unique and have the potential possibility for authentication in view of pattern recognition. PMID:25126604

  20. The potential of using brain images for authentication.

    PubMed

    Chen, Fanglin; Zhou, Zongtan; Shen, Hui; Hu, Dewen

    2014-01-01

    Biometric recognition (also known as biometrics) refers to the automated recognition of individuals based on their biological or behavioral traits. Examples of biometric traits include fingerprint, palmprint, iris, and face. The brain is the most important and complex organ in the human body. Can it be used as a biometric trait? In this study, we analyze the uniqueness of the brain and try to use the brain for identity authentication. The proposed brain-based verification system operates in two stages: gray matter extraction and gray matter matching. A modified brain segmentation algorithm is implemented for extracting gray matter from an input brain image. Then, an alignment-based matching algorithm is developed for brain matching. Experimental results on two data sets show that the proposed brain recognition system meets the high accuracy requirement of identity authentication. Though currently the acquisition of the brain is still time consuming and expensive, brain images are highly unique and have the potential possibility for authentication in view of pattern recognition.

  1. Lower Pre-Treatment T Cell Activation in Early- and Late-Onset Tuberculosis-Associated Immune Reconstitution Inflammatory Syndrome

    PubMed Central

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ondoa, Pascale; Ceulemans, Ann; Vereecken, Chris; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc

    2015-01-01

    Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an inflammatory complication in HIV-TB co-infected patients receiving antiretroviral therapy (ART). The role of disturbed T cell reconstitution in TB-IRIS is not well understood. We investigated T cell activation and maturation profiles in patients who developed TB-IRIS at different intervals during ART. Methods Twenty-two HIV-TB patients who developed early-onset TB-IRIS and 10 who developed late-onset TB-IRIS were matched for age, sex and CD4 count to equal numbers of HIV-TB patients who did not develop TB-IRIS. Flow cytometry analysis was performed on fresh blood, drawn before and after ART initiation and during TB-IRIS events. T cell activation and maturation was measured on CD4+ and CD8+ T cells using CD45RO, CD38, HLA-DR, CCR7 and CD27 antibodies. Results CD8+ T cell activation before ART was decreased in both early-onset (77% vs. 82%, p = 0.014) and late-onset (71% vs. 83%, p = 0.012) TB-IRIS patients compared to non-IRIS controls. After ART initiation, the observed differences in T cell activation disappeared. During late-onset, but not early-onset TB-IRIS, we observed a skewing from memory to terminal effector CD4+ and CD8+ T cell populations (p≤0.028). Conclusion Our data provide evidence of reduced CD8+ T cell activation before ART as a common predisposing factor of early- and late-onset TB-IRIS. The occurrence of TB-IRIS itself was not marked by an over-activated CD8+ T cell compartment. Late- but not early-onset TB-IRIS was characterized by a more terminally differentiated T cell phenotype. PMID:26208109

  2. Comparative evaluation of NeQuick and IRI models over Polar Regions

    NASA Astrophysics Data System (ADS)

    Pietrella, Marco; Nava, Bruno; Pezzopane, Michael; Migoya-Orue, Yenca; Scotto, Carlo

    2016-04-01

    In the framework of the AUSPICIO (AUtomatic Scaling of Polar Ionograms and Cooperative Ionospheric Observations) project, the ionograms recorded at Hobart (middle latitude), Macquarie Island, Livingstone Island and Comandante Ferraz (middle-high latitude) and those recorded at the ionospheric observatories of Casey, Mawson, Davis, and Scott Base (Antarctic Polar Circle), have been taken into account to study the capability of NeQuick-2 and IRI-2012 models in predicting the behavior of the ionosphere, mainly in the polar region. In particular, the applicability of NeQuick-2 and IRI-2012 models was evaluated under two different modes: a) as assimilative models ingesting the foF2 and hmF2 measurements obtained from the electron density profiles provided by the Adaptive Ionospheric Profiler (AIP); b) as climatological models taking as input F10.7 solar activity index. The results obtained from the large number of comparisons made for each ionospheric observatory when NeQuick-2 and IRI-2012 models work according to the two modes above mentioned, reveal that the best description of the ionosphere electron density at the polar regions is provided when peak parameter data are ingested in near-real-time into NeQuick-2 and IRI-2012 models which, indeed, are not always able to represent efficiently the behavior of the ionosphere over the polar regions when operating in long term prediction mode. The statistical analysis results expressed in terms of root mean square errors (r.m.s.e.) for each ionospheric observatory show that, outside the Antarctic Polar Circle (APC), NeQuick-2 performance is better than the IRI-2012 performance; on the contrary, inside the APC IRI-2012 model performs better than NeQuick-2.

  3. Noninvasive intratissue refractive index shaping (IRIS) of the cornea with blue femtosecond laser light.

    PubMed

    Xu, Lisen; Knox, Wayne H; DeMagistris, Margaret; Wang, Nadan; Huxlin, Krystel R

    2011-10-17

    To test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses. Fresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death. Scanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns. Blue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique.

  4. Noninvasive Intratissue Refractive Index Shaping (IRIS) of the Cornea with Blue Femtosecond Laser Light

    PubMed Central

    Xu, Lisen; Knox, Wayne H.; DeMagistris, Margaret; Wang, Nadan

    2011-01-01

    Purpose. To test the feasibility of intratissue refractive index shaping (IRIS) in living corneas by using 400-nm femtosecond (fs) laser pulses (blue-IRIS). To test the hypothesis that the intrinsic two-photon absorption of the cornea allows blue-IRIS to be performed with greater efficacy than when using 800-nm femtosecond laser pulses. Methods. Fresh cat corneas were obtained postmortem and cut into six wedges. Blue laser pulses at 400 nm, with 100-fs pulse duration at 80 MHz were used to micromachine phase gratings into each corneal wedge at scanning speeds from 1 to 15 mm/s. Grating lines were 1 μm wide, 5 μm apart, and 150 μm below the anterior corneal surface. Refractive index (RI) changes in micromachined regions were measured immediately by recording the diffraction efficiency of inscribed gratings. Six hours later, the corneas were processed for histology, and TUNEL staining was performed to assess whether blue-IRIS causes cell death. Results. Scanning at 1 and 2 mm/s caused overt corneal damage in the form of bubbles and burns. At faster scanning speeds (5, 10, and 15 mm/s), phase gratings were created in the corneal stroma, which were shown to be pure RI changes ranging from 0.037 to 0.021 in magnitude. The magnitude of RI change was inversely related to scanning speed. TUNEL staining showed cell death only around bubbles and burns. Conclusions. Blue-IRIS can be performed safely and effectively in living cornea. Compared with near-infrared laser pulses, blue-IRIS enhances both achievable RI change and scanning speed without the need to dope the tissue with two-photon sensitizers, increasing the clinical applicability of this technique. PMID:21931133

  5. Renal ischemia-reperfusion injury and adenosine 2A receptor-mediated tissue protection: the role of CD4+ T cells and IFN-gamma.

    PubMed

    Day, Yuan-Ji; Huang, Liping; Ye, Hong; Li, Li; Linden, Joel; Okusa, Mark D

    2006-03-01

    A(2A) adenosine receptor (A(2A)R)-expressing bone marrow (BM)-derived cells contribute to the renal protective effect of A(2A) agonists in renal ischemia-reperfusion injury (IRI). We performed IRI in mice lacking T and B cells to determine whether A(2A)R expressed in CD4+ cells mediate protection from IRI. Rag-1 knockout (KO) mice were protected in comparison to wild-type (WT) mice when subjected to IRI. ATL146e, a selective A(2A) agonist, did not confer additional protection. IFN-gamma is an important early signal in IRI and is thought to contribute to reperfusion injury. Because IFN-gamma is produced by kidney cells and T cells we performed IRI in BM chimeras in which the BM of WT mice was reconstituted with BM from IFN-gamma KO mice (IFN-gamma KO-->WT chimera). We observed marked reduction in IRI in comparison to WT-->WT chimeras providing additional indirect support for the role of T cells. To confirm the role of CD4+ A(2A)R in mediating protection from IRI, Rag-1 KO mice were subjected to ischemia-reperfusion. The protection observed in Rag-1 KO mice was reversed in Rag-1 KO mice that were adoptively transferred WT CD4+ cells (WT CD4+-->Rag-1 KO) or A(2A) KO CD4+ cells (A(2A) KO CD4+-->Rag-1 KO). ATL146e reduced injury in WT CD4+-->Rag-1 KO mice but not in A(2A) KO CD4+-->Rag-1 KO mice. Rag-1 KO mice reconstituted with CD4+ cells derived from IFN-gamma KO mice (IFN-gamma CD4+-->Rag-1 KO) were protected from IRI; ATL146e conferred no additional protection. These studies demonstrate that CD4+ IFN-gamma contributes to IRI and that A(2A) agonists mediate protection from IRI through action on CD4+ cells.

  6. Implantation of ArtificialIris, a CustomFlex irisprosthesis, in a trauma patient with an Artisan lens

    PubMed Central

    Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad

    2017-01-01

    Abstract Purpose: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Results: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs. PMID:29137026

  7. Incidence and Predictors of Immune Reconstitution Inflammatory Syndrome in a Rural Area of Mozambique

    PubMed Central

    Letang, Emilio; Miró, José M.; Nhampossa, Tacilta; Ayala, Edgar; Gascon, Joaquim; Menéndez, Clara; Alonso, Pedro L.; Naniche, Denise

    2011-01-01

    Background There is limited data on the epidemiology of Immune Reconstitution Inflammatory Syndrome (IRIS) in rural sub-Saharan Africa. A prospective observational cohort study was conducted to assess the incidence, clinical characteristics, outcome and predictors of IRIS in rural Mozambique. Methods One hundred and thirty-six consecutive antiretroviral treatment (ART)-naïve HIV-1-infected patients initiating ART at the Manhiça district hospital were prospectively followed for development of IRIS over 16 months. Survival analysis by Cox regression was performed to identify pre-ART predictors of IRIS development. Results Thirty-six patients developed IRIS [26.5%, incidence rate 3.1 cases/100 persons-month of ART (95% CI 2.2–4.3)]. Median time to IRIS onset was 62 days from ART initiation (IQR 35.5–93.5). Twenty-five cases (69.4%) were “unmasking”, 10 (27.8%) were “paradoxical”, and 1 (2.8%) developed a paradoxical worsening followed by the unmasking of another condition. Systemic OI (OI-IRIS) accounted for 47% (17/36) of IRIS cases, predominantly of KS (8 cases) and TB (6 cases) IRIS. Mucocutaneous IRIS manifestations (MC-IRIS) accounted for 53% (19/36) of IRIS events, mostly tinea (9 cases) and herpes simplex infection (3 cases). Multivariate analysis identified two independent predictors of IRIS development: pre-ART CD4 count <50 cells/µl (HR 2.3, 95% CI 1.19–4.44, p = 0.01) and body mass index (BMI) <18.5 (HR 2.15, 95% CI 1.07–4.3, p = 0.03). The pre-cART proportion of activated T-cells, as well as the immunologic and virologic response to ART were not associated with IRIS development. All patients continued on ART, 7 (19.4%) required hospitalization and there were 3 deaths (8.3%) attributable to IRIS. Conclusions IRIS is common in patients initiating ART in rural Mozambique. Pre-ART CD4 counts and BMI can easily be assessed at ART initiation in rural sub-Saharan Africa to identify patients at high risk of IRIS, for whom close supervision is warranted. PMID:21386993

  8. Advanced optical correlation and digital methods for pattern matching—50th anniversary of Vander Lugt matched filter

    NASA Astrophysics Data System (ADS)

    Millán, María S.

    2012-10-01

    On the verge of the 50th anniversary of Vander Lugt’s formulation for pattern matching based on matched filtering and optical correlation, we acknowledge the very intense research activity developed in the field of correlation-based pattern recognition during this period of time. The paper reviews some domains that appeared as emerging fields in the last years of the 20th century and have been developed later on in the 21st century. Such is the case of three-dimensional (3D) object recognition, biometric pattern matching, optical security and hybrid optical-digital processors. 3D object recognition is a challenging case of multidimensional image recognition because of its implications in the recognition of real-world objects independent of their perspective. Biometric recognition is essentially pattern recognition for which the personal identification is based on the authentication of a specific physiological characteristic possessed by the subject (e.g. fingerprint, face, iris, retina, and multifactor combinations). Biometric recognition often appears combined with encryption-decryption processes to secure information. The optical implementations of correlation-based pattern recognition processes still rely on the 4f-correlator, the joint transform correlator, or some of their variants. But the many applications developed in the field have been pushing the systems for a continuous improvement of their architectures and algorithms, thus leading towards merged optical-digital solutions.

  9. Innate Immune Regulations and Liver Ischemia Reperfusion Injury

    PubMed Central

    Lu, Ling; Zhou, Haoming; Ni, Ming; Wang, Xuehao; Busuttil, Ronald; Kupiec-Weglinski, Jerzy; Zhai, Yuan

    2016-01-01

    Liver ischemia reperfusion activates innate immune system to drive the full development of inflammatory hepatocellular injury. Damage-associated molecular patterns (DAMPs) stimulate myeloid and dendritic cells via pattern recognition receptors (PRRs) to initiate the immune response. Complex intracellular signaling network transduces inflammatory signaling to regulate both innate immune cell activation and parenchymal cell death. Recent studies have revealed that DAMPs may trigger not only proinflammatory, but also immune regulatory responses by activating different PRRs or distinctive intracellular signaling pathways or in special cell populations. Additionally, tissue injury milieu activates PRR-independent receptors which also regulate inflammatory disease processes. Thus, the innate immune mechanism of liver IRI involves diverse molecular and cellular interactions, subjected to both endogenous and exogenous regulation in different cells. A better understanding of these complicated regulatory pathways/network is imperative for us in designing safe and effective therapeutic strategy to ameliorate liver IRI in patients. PMID:27861288

  10. Effective Solar Indices for Ionospheric Modeling: A Review and a Proposal for a Real-Time Regional IRI

    NASA Astrophysics Data System (ADS)

    Pignalberi, A.; Pezzopane, M.; Rizzi, R.; Galkin, I.

    2018-01-01

    The first part of this paper reviews methods using effective solar indices to update a background ionospheric model focusing on those employing the Kriging method to perform the spatial interpolation. Then, it proposes a method to update the International Reference Ionosphere (IRI) model through the assimilation of data collected by a European ionosonde network. The method, called International Reference Ionosphere UPdate (IRI UP), that can potentially operate in real time, is mathematically described and validated for the period 9-25 March 2015 (a time window including the well-known St. Patrick storm occurred on 17 March), using IRI and IRI Real Time Assimilative Model (IRTAM) models as the reference. It relies on foF2 and M(3000)F2 ionospheric characteristics, recorded routinely by a network of 12 European ionosonde stations, which are used to calculate for each station effective values of IRI indices IG_{12} and R_{12} (identified as IG_{{12{eff}}} and R_{{12{eff}}}); then, starting from this discrete dataset of values, two-dimensional (2D) maps of IG_{{12{eff}}} and R_{{12{eff}}} are generated through the universal Kriging method. Five variogram models are proposed and tested statistically to select the best performer for each effective index. Then, computed maps of IG_{{12{eff}}} and R_{{12{eff}}} are used in the IRI model to synthesize updated values of foF2 and hmF2. To evaluate the ability of the proposed method to reproduce rapid local changes that are common under disturbed conditions, quality metrics are calculated for two test stations whose measurements were not assimilated in IRI UP, Fairford (51.7°N, 1.5°W) and San Vito (40.6°N, 17.8°E), for IRI, IRI UP, and IRTAM models. The proposed method turns out to be very effective under highly disturbed conditions, with significant improvements of the foF2 representation and noticeable improvements of the hmF2 one. Important improvements have been verified also for quiet and moderately disturbed conditions. A visual analysis of foF2 and hmF2 maps highlights the ability of the IRI UP method to catch small-scale changes occurring under disturbed conditions which are not seen by IRI.

  11. Medical information security in the era of artificial intelligence.

    PubMed

    Wang, Yufeng; Wang, Liwei; Xue, Chang-Ao

    2018-06-01

    In recent years, biometric technologies, such as iris, facial, and finger vein recognition, have reached consumers and are being increasingly applied. However, it remains unknown whether these highly specific biometric technologies are as safe as declared by their manufacturers. As three-dimensional (3D) reconstruction based on medical imaging and 3D printing are being developed, these biometric technologies may face severe challenges. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. [Functional analysis of Grp and Iris, the gag and env domesticated errantivirus genes, in the Drosophila melanogaster genome].

    PubMed

    Makhnovskii, P A; Kuzmin, I V; Nefedova, L N; Kima, A I

    2016-01-01

    Drosophila melanogaster is the only invertebrate that contains endogenous retroviruses, which are called errantiviruses. Two domesticated genes, Grp and Iris, which originate from errantivirus gag and env, respectively, have been found in the D. melanogaster genome. The functions performed by the genes in Drosophila are still unclear. To identify the functions of domesticated gag and env in the D. melanogaster genome, expression of Iris and Grp was studied in strains differing by the presence or absence of the functional gypsy errantivirus. In addition, the expression levels were measured after injection of gram-positive and gram-negative bacteria, which activate different immune response pathways, and exposure to various abiotic stress factors. The presence of functional D. melanogaster retrovirus gypsy was found to increase the Grp expression level in somatic tissues of the carcass, while exerting no effect on the Iris expression level. Activation of the immune response in D. melanogaster by bacteria Bacillus cereus increased the Grp expression level and did not affect Iris expression. As for the effects of abiotic stress factors (oxidative stress, starvation, and heat and cold stress), the Grp expression level increased in response to starvation in D. melanogaster females, and the Iris expression level was downregulated in heat shock and oxidative stress. Based on the findings, Grp was assumed to play a direct role in the immune response in D. melanogaster; Iris is not involved in immune responses, but and apparently performs a cell function that is inhibited in stress.

  13. NeQuick 2 and IRI Plas VTEC predictions for low latitude and South American sector

    NASA Astrophysics Data System (ADS)

    Ezquer, R. G.; Scidá, L. A.; Migoya Orué, Y.; Nava, B.; Cabrera, M. A.; Brunini, C.

    2018-04-01

    Using vertical total electron content (VTEC) measurements obtained from GPS satellite signals the capability of the NeQuick 2 and IRI Plas models to predict VTEC over the low latitude and South American sector is analyzed. In the present work both models were used to calculate VTEC up to the height of GPS satellites. Also, comparisons between the performance of IRI Plas and IRI 2007 have been done. The data correspond to June solstice and September equinox 1999 (high solar activity) and they were obtained at nine stations. The considered latitude range extends from 18.4°N to -64.7°N and the longitude ranges from 281.3°E to 295.9°E in the South American sector. The greatest discrepancies among model predictions and the measured VTEC are obtained at low latitudes stations placed in the equatorial anomaly region. Underestimations as strong as 40 TECU [1 TECU = 1016 m-2] can be observed at BOGT station for September equinox, when NeQuick2 model is used. The obtained results also show that: (a) for June solstice, in general the performance of IRI Plas for low latitude stations is better than that of NeQuick2 and, vice versa, for highest latitudes the performance of NeQuick2 is better than that of IRI Plas. For the stations TUCU and SANT both models have good performance; (b) for September equinox the performances of the models do not follow a clearly defined pattern as in the other season. However, it can be seen that for the region placed between the Northern peak and the valley of the equatorial anomaly, in general, the performance of IRI Plas is better than that of NeQuick2 for hours of maximum ionization. From TUCU to the South, the best TEC predictions are given by NeQuick2. The source of the observed deviations of the models has been explored in terms of CCIR foF2 determination in the available ionosonde stations in the region. Discrepancies can be also related to an unrealistic shape of the vertical electron density profile and or an erroneous prediction of the plasmaspheric contribution to the vertical total electron content. Moreover, the results of this study could be suggesting that in the case of NeQuick, the underestimation trend could be due to the lack of a proper plasmaspheric model in its topside representation. In contrast, the plasmaspheric model included in IRI, leads to clear overestimations of GPS derived TEC.

  14. Comparison between the Juno Earth flyby magnetic measurements and the magnetometer package on the IRIS solar observatory

    NASA Astrophysics Data System (ADS)

    Merayo, J. M.; Connerney, J. E.; Joergensen, J. L.; Dougherty, B.

    2013-12-01

    In October 2013 the NASA's Juno New Frontier spacecraft will perform an Earth Flyby Gravity Assist. During this flyby, Juno will reach an altitude of about 600 km and the magnetometer experiment will measure the magnetic field with very high precision. In June 2013 the NASA's IRIS solar observatory was successfully launched. IRIS uses a very fine guiding telescope in order to maintain a high pointing accuracy, assisted by a very high accuracy star tracker and a science grade vector magnetometer. IRIS was placed into a Sun-synchronous orbit at about 600 km altitude by a Pegasus rocket from the Vandenberg Air Force Base in California. This platform will also allow to performing measurements of the Earth's magnetic field with very high precision, since it carries similar instrumentation as on the Swarm satellites (star trackers and magnetometer). The data recorded by the Juno magnetic experiment and the IRIS magnetometer will bring a very exciting opportunity for comparing the two experiments as well as for determining current structures during the flyby.

  15. Comparison of anterior segment optical coherence tomography angiography and fluorescein angiography for iris vasculature analysis.

    PubMed

    Zett, Claudio; Stina, Deborah M Rosa; Kato, Renata Tiemi; Novais, Eduardo Amorim; Allemann, Norma

    2018-04-01

    The aim of this study is to perform imaging of irises of different colors using spectral domain anterior segment optical coherence tomography angiography (AS-OCTA) and iris fluorescein angiography (IFA) and compare their effectiveness in examining iris vasculature. This is a cross-sectional observational clinical study. Patients with no vascular iris alterations and different pigmentation levels were recruited. Participants were imaged using OCTA adapted with an anterior segment lens and IFA with a confocal scanning laser ophthalmoscope (cSLO) adapted with an anterior segment lens. AS-OCTA and IFA images were then compared. Two blinded readers classified iris pigmentation and compared the percentage of visible vessels between OCTA and IFA images. Twenty eyes of 10 patients with different degrees of iris pigmentation were imaged using AS-OCTA and IFA. Significantly more visible iris vessels were observed using OCTA than using FA (W = 5.22; p < 0.001). Iris pigmentation was negatively correlated to the percentage of visible vessels in both imaging methods (OCTA, rho = - 0.73, p < 0.001; IFA, rho = - 0.77, p < 0.001). Unlike FA, AS-OCTA could not detect leakage of dye, delay, or impregnation. Nystagmus and inadequate fixation along with motion artifacts resulted in lower quality images in AS-OCTA than in IFA. AS-OCTA is a new imaging modality which allows analysis of iris vasculature. In both AS-OCTA and IFA, iris pigmentation caused vasculature imaging blockage, but AS-OCTA provided more detailed iris vasculature images than IFA. Additional studies including different iris pathologies are needed to determine the most optimal scanning parameters in OCTA of the anterior segment.

  16. The concave iris in pigment dispersion syndrome.

    PubMed

    Liu, Lance; Ong, Ee Lin; Crowston, Jonathan

    2011-01-01

    To visualize the changes of the iris contour in patients with pigment dispersion syndrome after blinking, accommodation, and pharmacologic miosis using anterior segment optical coherence tomography. Observational case series. A total of 33 eyes of 20 patients with pigment dispersion syndrome. Each eye was imaged along the horizontal 0- to 180-degree meridian using the Visante Anterior Segment Imaging System (Carl Zeiss Meditec, Dublin, CA). Scans were performed at baseline and after focusing on an internal fixation target for 5 minutes, forced blinking, accommodation, and pharmacologic miosis with pilocarpine 2%. Quantitative analysis of the changes in the iris configuration. After 5 minutes of continual fixation, the iris became planar with the mean ± standard deviation curvature decreasing from 214 ± 74 μm to 67 ± 76 μm (P < 0.05). The iris remained planar in all patients with pigment dispersion syndrome after forced blinking, but the iris concavity recovered to 227 ± 113 μm (P = 0.34) and 238 ± 119 μm (P = 0.19) with the -3.0 and -6.0 diopter lenses, respectively. Pilocarpine-induced miosis caused the iris to assume a planar configuration in all subjects. This study shows that the iris in pigment dispersion syndrome assumes a planar configuration when fixating and that the concavity of the iris surface is not restored by blinking. Accommodation restored the iris concavity, suggesting that the posterior curvature of the iris in pigment dispersion syndrome is induced and probably maintained, at least in part, by accommodation. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Qualitative evaluation of the iris and ciliary body by ultrasound biomicroscopy in subjects with angle closure.

    PubMed

    Ku, Judy Y; Nongpiur, Monisha E; Park, Judy; Narayanaswamy, Arun K; Perera, Shamira A; Tun, Tin A; Kumar, Rajesh S; Baskaran, Mani; Aung, Tin

    2014-12-01

    To qualitatively analyze anterior chamber structures imaged by ultrasound biomicroscopy (UBM) in primary angle-closure patients. Subjects diagnosed as primary angle-closure suspect (PACS), primary angle-closure glaucoma (PACG), and previous acute primary angle closure (APAC) were recruited prospectively along with a group of normal controls. UBM was performed under standardized dark room conditions and qualitative assessment was carried out using a set of reference photographs of standard UBM images to categorize the various anatomic features related to angle configuration. These included overall and basal iris thicknesses, iris convexity, iris angulation, ciliary body size, and ciliary sulcus. A total of 60 PACS, 114 PACG, 41 APAC, and 33 normal controls were included. Patients were predominantly older Chinese females. After controlling the confounding effect of age and sex, eyes with overall thicker irides [medium odds ratio (OR) 3.58, thick OR 2.84] when compared with thin irides have a significantly higher likelihood of having PACS/PACG/APAC versus controls. Thicker basal iris component (medium OR 4.13, thick OR 3.39) also have higher likelihood of having angle closure when compared with thin basal iris thickness. Subjects with basal iris insertion, mild iris angulation, and large ciliary body have a higher OR of having angle closure. In contrast, the presence/absence of a ciliary sulcus did not influence the likelihood of angle closure. Eyes with thicker overall and basal iris thicknesses are more likely to have angle closure than controls. Other features that increase the likelihood of angle closure include basal iris insertion, mild iris angulation, and large ciliary body.

  18. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of Beryllium was added to the IRIS database in 1998. The IRIS program is updating the IRIS assessment for Beryllium. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for Beryllium will consist of an updated Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of Beryllium (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency and Interagency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of Beryllium. Beryllium is a light alkaline earth metal used in metal alloys and in high-performance products in the metallurgical, aerospace, and nuclear industries. According to the Superfund database, beryllium is found in over 300 NPL sites

  19. Double hump sign in indentation gonioscopy is correlated with presence of plateau iris configuration regardless of patent iridotomy.

    PubMed

    Kiuchi, Yoshiaki; Kanamoto, Takashi; Nakamura, Takao

    2009-02-01

    A plateau iris is one of the clinical forms of angle closure glaucoma. In patients with a patent iridotomy, the double hump sign detected during indentation gonioscopy has been reported to indicate the existence of a plateau iris configuration. The purpose of this study was to determine whether the double hump sign is correlated with the presence of the plateau iris syndrome regardless of the patency of the iridotomy. Five women and 3 men without a patent iridotomy presented with narrow angles on gonioscopy and a double hump sign on indentation gonioscopy. Ultrasound biomicroscopy (UBM) imaging was performed to determine the etiology of the narrow angle and double hump sign, and to determine the appropriate treatment to prevent the progression of visual field damage. Ten patients with narrow angles and without a double hump sign were also examined by UBM to serve as a control group. All 8 patients who showed double hump sign had a short iris root, which was inserted anterior to the ciliary face, a typical anatomic appearance of a plateau iris. On the other hand, only 1 eye of 10 eyes in control group appeared to have a plateau iris. A double hump sign observed on indentation gonioscopy is strongly correlated with the presence of a plateau iris, and therefore a useful indicator of a plateau iris configuration regardless of the patency of a laser iridotomy. Thus, a plateau iris configuration can be detected without using a UBM in many cases.

  20. Iris reconstruction using autologous iris preserved in cold balanced salt solution for 8 hours in iatrogenic total iridodialysis during cataract surgery: a case report.

    PubMed

    Bang, Seung Pil; Jun, Jong Hwa

    2017-04-04

    A large iris defect or extensive iridodialysis can be an intractable cause of visual disturbance, photophobia, glare, monocular diplopia, or cosmetic deformity. The implantation of an artificial iris substitute could be an effective option, but this can cause a reduction in endothelial cell density. We succeeded in the anatomical restoration of iris tissue that was totally dialyzed out of the eye, and was preserved in cold balanced salt solution for 8 h. Engrafted iris tissue was maintained within the aqueous humor. A 71-year-old man was referred to our clinic for management of an iatrogenic total iridodialysis. The totally dialyzed iris tissue was immediately preserved in sterile cold balanced salt solution and packed in a sterile biopsy bottle that was surrounded with ice cubes. Under general anesthesia, a pars plana vitrectomy was performed to remove the remaining lens cortex and vitreous fiber anterior to the equator. A sulcus-positioned intraocular lens (IOL) was repositioned and fixed by ab externo scleral sutures. Preserved iris tissue was inserted and ironed using both iris spatula and ocular viscoelastic devices. Five-point ab interno scleral sutures were made 1.0 mm posterior to the limbus. The engrafted iris was successfully maintained for 6 months and did not undergo any atrophic change or depigmentation, which may be caused by primary implantation failure due to a blocked blood supply.

  1. Irido-lenticular abscess as the initial sign of Candida albicans endogenous endophthalmitis.

    PubMed

    Braich, Puneet S; Chang, Jonathan S; Albini, Thomas A; Schefler, Amy C

    2011-12-08

    A-33-year-old man presented with 9 days of conjunctival erythema, pain, and worsening vision in the left eye. Anterior segment examination was significant for a well-defined, cream-colored iridociliary mass. Ultrasound biomicroscopy demonstrated an iris lesion with ciliary body and lenticular involvement. The authors performed a pars plana vitrectomy and lensectomy with an iris biopsy. Culture of the vitreous cassette and iris mass yielded a diagnosis of Candida albicans endophthalmitis. Clinicians encountering an iris nodule with lenticular involvement, even in an immunocompetent adult, are urged to consider a diagnosis of an endogenous endophthalmitis secondary to C. albicans. Copyright 2011, SLACK Incorporated.

  2. Methylene blue-related corneal edema and iris discoloration.

    PubMed

    Timucin, Ozgur Bulent; Karadag, Mehmet Fatih; Aslanci, Mehmet Emin; Baykara, Mehmet

    2016-04-01

    We report the case of a 70-year-old female patient who developed corneal edema and iris discoloration following the inadvertent use of 1% methylene blue instead of 0.025% trypan blue to stain the anterior capsule during cataract phacoemulsification surgery. Copious irrigation was performed upon realization of incorrect dye use. Corneal edema and iris discoloration developed during the early postoperative period and persisted at 24-months follow-up. However, keratoplasty was not required. The intracameral use of 1% methylene blue has a cytotoxic effect on the corneal endothelium and iris epithelium. Copious irrigation for at least 30 min using an anterior chamber maintainer may improve outcomes.

  3. Improving energy efficiency in handheld biometric applications

    NASA Astrophysics Data System (ADS)

    Hoyle, David C.; Gale, John W.; Schultz, Robert C.; Rakvic, Ryan N.; Ives, Robert W.

    2012-06-01

    With improved smartphone and tablet technology, it is becoming increasingly feasible to implement powerful biometric recognition algorithms on portable devices. Typical iris recognition algorithms, such as Ridge Energy Direction (RED), utilize two-dimensional convolution in their implementation. This paper explores the energy consumption implications of 12 different methods of implementing two-dimensional convolution on a portable device. Typically, convolution is implemented using floating point operations. If a given algorithm implemented integer convolution vice floating point convolution, it could drastically reduce the energy consumed by the processor. The 12 methods compared include 4 major categories: Integer C, Integer Java, Floating Point C, and Floating Point Java. Each major category is further divided into 3 implementations: variable size looped convolution, static size looped convolution, and unrolled looped convolution. All testing was performed using the HTC Thunderbolt with energy measured directly using a Tektronix TDS5104B Digital Phosphor oscilloscope. Results indicate that energy savings as high as 75% are possible by using Integer C versus Floating Point C. Considering the relative proportion of processing time that convolution is responsible for in a typical algorithm, the savings in energy would likely result in significantly greater time between battery charges.

  4. Design and performance of a cryogenic iris aperture mechanism

    NASA Astrophysics Data System (ADS)

    de Jonge, C.; Laauwen, W. M.; de Vries, E. A.; Smit, H. P.; Detrain, A.; Eggens, M. J.; Ferrari, L.; Dieleman, P.

    2014-07-01

    A cryogenic iris mechanism is under development as part of the ground calibration source for the SAFARI instrument. The iris mechanism is a variable aperture used as an optical shutter to fine-tune and modulate the absolute power output of the calibration source. It has 4 stainless steel blades that create a near-circular aperture in every position. The operating temperature is 4.5 Kelvin to provide a negligible background to the SAFARI detectors, and `hot spots' above 9K should be prevented. Cryogenic testing proved that the iris works at 4K. It can be used in a broad range of cryogenic optical instruments where optical throughput needs to be controlled. Challenges in the design include the low cooling power available (5mW) and low friction at cryogenic temperatures. The actuator is an `arc-type' rotary voice-coil motor. The use of flexural pivots creates a mono-stable mechanism with a resonance frequency at 26Hz. Accurate and fast position control with disturbance rejection is managed by a PID servo loop using a hall-sensor as input. At 4 Kelvin, the frequency is limited to 4Hz to avoid excess dissipation and heating. In this paper, the design and performance of the iris are discussed. The design was optimized using a thermal, magnetic and mechanical model made with COMSOL Finite Element Analysis software. The dynamical and state-space modeling of the mechanism and the concept of the electrical control are presented. The performance of the iris show good agreement to the analytical and COMSOL modeling.

  5. Human body as a set of biometric features identified by means of optoelectronics

    NASA Astrophysics Data System (ADS)

    Podbielska, Halina; Bauer, Joanna

    2005-09-01

    Human body posses many unique, singular features that are impossible to copy or forge. Nowadays, to establish and to ensure the public security requires specially designed devices and systems. Biometrics is a field of science and technology, exploiting human body characteristics for people recognition. It identifies the most characteristic and unique ones in order to design and construct systems capable to recognize people. In this paper some overview is given, presenting the achievements in biometrics. The verification and identification process is explained, along with the way of evaluation of biometric recognition systems. The most frequently human biometrics used in practice are shortly presented, including fingerprints, facial imaging (including thermal characteristic), hand geometry and iris patterns.

  6. Frontal sinus recognition for human identification

    NASA Astrophysics Data System (ADS)

    Falguera, Juan Rogelio; Falguera, Fernanda Pereira Sartori; Marana, Aparecido Nilceu

    2008-03-01

    Many methods based on biometrics such as fingerprint, face, iris, and retina have been proposed for person identification. However, for deceased individuals, such biometric measurements are not available. In such cases, parts of the human skeleton can be used for identification, such as dental records, thorax, vertebrae, shoulder, and frontal sinus. It has been established in prior investigations that the radiographic pattern of frontal sinus is highly variable and unique for every individual. This has stimulated the proposition of measurements of the frontal sinus pattern, obtained from x-ray films, for skeletal identification. This paper presents a frontal sinus recognition method for human identification based on Image Foresting Transform and shape context. Experimental results (ERR = 5,82%) have shown the effectiveness of the proposed method.

  7. Efficient quantitative assessment of facial paralysis using iris segmentation and active contour-based key points detection with hybrid classifier.

    PubMed

    Barbosa, Jocelyn; Lee, Kyubum; Lee, Sunwon; Lodhi, Bilal; Cho, Jae-Gu; Seo, Woo-Keun; Kang, Jaewoo

    2016-03-12

    Facial palsy or paralysis (FP) is a symptom that loses voluntary muscles movement in one side of the human face, which could be very devastating in the part of the patients. Traditional methods are solely dependent to clinician's judgment and therefore time consuming and subjective in nature. Hence, a quantitative assessment system becomes apparently invaluable for physicians to begin the rehabilitation process; and to produce a reliable and robust method is challenging and still underway. We introduce a novel approach for a quantitative assessment of facial paralysis that tackles classification problem for FP type and degree of severity. Specifically, a novel method of quantitative assessment is presented: an algorithm that extracts the human iris and detects facial landmarks; and a hybrid approach combining the rule-based and machine learning algorithm to analyze and prognosticate facial paralysis using the captured images. A method combining the optimized Daugman's algorithm and Localized Active Contour (LAC) model is proposed to efficiently extract the iris and facial landmark or key points. To improve the performance of LAC, appropriate parameters of initial evolving curve for facial features' segmentation are automatically selected. The symmetry score is measured by the ratio between features extracted from the two sides of the face. Hybrid classifiers (i.e. rule-based with regularized logistic regression) were employed for discriminating healthy and unhealthy subjects, FP type classification, and for facial paralysis grading based on House-Brackmann (H-B) scale. Quantitative analysis was performed to evaluate the performance of the proposed approach. Experiments show that the proposed method demonstrates its efficiency. Facial movement feature extraction on facial images based on iris segmentation and LAC-based key point detection along with a hybrid classifier provides a more efficient way of addressing classification problem on facial palsy type and degree of severity. Combining iris segmentation and key point-based method has several merits that are essential for our real application. Aside from the facial key points, iris segmentation provides significant contribution as it describes the changes of the iris exposure while performing some facial expressions. It reveals the significant difference between the healthy side and the severe palsy side when raising eyebrows with both eyes directed upward, and can model the typical changes in the iris region.

  8. The infrared imaging spectrograph (IRIS) for TMT: latest science cases and simulations

    NASA Astrophysics Data System (ADS)

    Wright, Shelley A.; Walth, Gregory; Do, Tuan; Marshall, Daniel; Larkin, James E.; Moore, Anna M.; Adamkovics, Mate; Andersen, David; Armus, Lee; Barth, Aaron; Cote, Patrick; Cooke, Jeff; Chisholm, Eric M.; Davidge, Timothy; Dunn, Jennifer S.; Dumas, Christophe; Ellerbroek, Brent L.; Ghez, Andrea M.; Hao, Lei; Hayano, Yutaka; Liu, Michael; Lopez-Rodriguez, Enrique; Lu, Jessica R.; Mao, Shude; Marois, Christian; Pandey, Shashi B.; Phillips, Andrew C.; Schoeck, Matthias; Subramaniam, Annapurni; Subramanian, Smitha; Suzuki, Ryuji; Tan, Jonathan C.; Terai, Tsuyoshi; Treu, Tommaso; Simard, Luc; Weiss, Jason L.; Wincentsen, James; Wong, Michael; Zhang, Kai

    2016-07-01

    The Thirty Meter Telescope (TMT) first light instrument IRIS (Infrared Imaging Spectrograph) will complete its preliminary design phase in 2016. The IRIS instrument design includes a near-infrared (0.85 - 2.4 micron) integral field spectrograph (IFS) and imager that are able to conduct simultaneous diffraction-limited observations behind the advanced adaptive optics system NFIRAOS. The IRIS science cases have continued to be developed and new science studies have been investigated to aid in technical performance and design requirements. In this development phase, the IRIS science team has paid particular attention to the selection of filters, gratings, sensitivities of the entire system, and science cases that will benefit from the parallel mode of the IFS and imaging camera. We present new science cases for IRIS using the latest end-to-end data simulator on the following topics: Solar System bodies, the Galactic center, active galactic nuclei (AGN), and distant gravitationally-lensed galaxies. We then briefly discuss the necessity of an advanced data management system and data reduction pipeline.

  9. Balloon cell nevus of the iris.

    PubMed

    Morcos, Mohib W; Odashiro, Alexandre; Bazin, Richard; Pereira, Patricia Rusa; O'Meara, Aisling; Burnier, Miguel N

    2014-12-01

    Balloon cell nevus is a rare histopathological lesion characterized by a predominance of large, vesicular and clear cells, called balloon cells. There is only 1 case of balloon cell nevus of the iris reported in the literature. A 55 year-old man presented a pigmented elevated lesion in the right iris since the age of 12 years old. The lesion had been growing for the past 2 years and excision was performed. Histopathological examination showed a balloon cell nevus composed of clear and vacuolated cells without atypia. A typical spindle cell nevus of the iris was also observed. The differential diagnosis included xanthomatous lesions, brown adipocyte or other adipocytic lesions, clear cell hidradenoma, metastatic clear cell carcinoma of the kidney and clear cell sarcoma. The tumor was positive for Melan A, S100 protein and HMB45. Balloon cell nevus of the iris is rare but should be considered in the differential diagnosis of melanocytic lesions of the iris. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. ENHANCED GENE DELIVERY IN PORCINE VASCULATURE TISSUE FOLLOWING INCORPORATION OF ADENO-ASSOCIATED VIRUS NANOPARTICLES INTO POROUS SILICON MICROPARTICLES

    PubMed Central

    McConnell, Kellie I.; Rhudy, Jessica; Yokoi, Kenji; Gu, Jianhua; Mack, Aaron; Suh, Junghae; La Francesca, Saverio; Sakamoto, Jason; Serda, Rita E.

    2014-01-01

    There is an unmet clinical need to increase lung transplant successes, patient satisfaction and to improve mortality rates. We offer the development of a nanovector-based solution that will reduce the incidence of lung ischemic reperfusion injury (IRI) leading to graft organ failure through the successful ex vivo treatment of the lung prior to transplantation. The innovation is in the integrated application of our novel porous silicon (pSi) microparticles carrying adeno-associated virus (AAV) nanoparticles, and the use of our ex vivo lung perfusion/ventilation system for the modulation of pro-inflammatory cytokines initiated by ischemic pulmonary conditions prior to organ transplant that often lead to complications. Gene delivery of anti-inflammatory agents to combat the inflammatory cascade may be a promising approach to prevent IRI following lung transplantation. The rationale for the device is that the microparticle will deliver a large payload of virus to cells and serve to protect the AAV from immune recognition. The microparticle-nanoparticle hybrid device was tested both in vitro on cell monolayers and ex vivo using either porcine venous tissue or a pig lung transplantation model, which recapitulates pulmonary IRI that occurs clinically post-transplantation. Remarkably, loading AAV vectors into pSi microparticles increases gene delivery to otherwise non-permissive endothelial cells. PMID:25180449

  11. Risk factors and frequency of tuberculosis-associated immune reconstitution inflammatory syndrome among HIV/Tuberculosis co-infected patients in Southern India.

    PubMed

    Vignesh, Ramachandran; Swathirajan, Chinnambedu R; Solomon, Sunil S; Shankar, Esaki Muthu; Murugavel, Kailapuri G

    2017-01-01

    Immune reconstitution inflammatory syndrome (IRIS) continues to be a complication in HIV/tuberculosis (TB) co-infected patients initiating highly active antiretroviral therapy (HAART). The aim of this study was to evaluate the risk factors associated with developing IRIS to identify a possible biomarker to predict or diagnose IRIS in patients initiating HAART. A total of 175 HIV/TB co-infected patients initiating HAART were followed up longitudinally during September 2010 to May 2013 attending a HIV care clinic in Chennai. Patients were followed up longitudinally after HAART initiation and baseline demographic, laboratory parameters and treatment characteristics between patients with IRIS events and those without IRIS events were compared. Chi-square or Fisher's exact test for categorical variables and a Wilcoxon rank-sum test for continuous variables were performed using SPSS, version 12.0 software. Patients with IRIS had a significantly lower median baseline CD4+ T-cell count (P = 0.0039). There were no differences in terms of sex, CD4 T-cell %, plasma viral load, time interval between initiating ATT and HAART between the IRIS and non-IRIS patients. Low CD4+ T-cell count (<100 cells/μL) could be used as a marker to screen and monitor patients initiating HAART.

  12. The infrared imaging spectrograph (IRIS) for TMT: overview of innovative science programs

    NASA Astrophysics Data System (ADS)

    Wright, Shelley A.; Larkin, James E.; Moore, Anna M.; Do, Tuan; Simard, Luc; Adamkovics, Maté; Armus, Lee; Barth, Aaron J.; Barton, Elizabeth; Boyce, Hope; Cooke, Jeffrey; Cote, Patrick; Davidge, Timothy; Ellerbroek, Brent; Ghez, Andrea M.; Liu, Michael C.; Lu, Jessica R.; Macintosh, Bruce A.; Mao, Shude; Marois, Christian; Schoeck, Matthias; Suzuki, Ryuji; Tan, Jonathan C.; Treu, Tommaso; Wang, Lianqi; Weiss, Jason

    2014-07-01

    IRIS (InfraRed Imaging Spectrograph) is a first light near-infrared diffraction limited imager and integral field spectrograph being designed for the future Thirty Meter Telescope (TMT). IRIS is optimized to perform astronomical studies across a significant fraction of cosmic time, from our Solar System to distant newly formed galaxies (Barton et al. [1]). We present a selection of the innovative science cases that are unique to IRIS in the era of upcoming space and ground-based telescopes. We focus on integral field spectroscopy of directly imaged exoplanet atmospheres, probing fundamental physics in the Galactic Center, measuring 104 to 1010 M supermassive black hole masses, resolved spectroscopy of young star-forming galaxies (1 < z < 5) and first light galaxies (6 < z < 12), and resolved spectroscopy of strong gravitational lensed sources to measure dark matter substructure. For each of these science cases we use the IRIS simulator (Wright et al. [2], Do et al. [3]) to explore IRIS capabilities. To highlight the unique IRIS capabilities, we also update the point and resolved source sensitivities for the integral field spectrograph (IFS) in all five broadband filters (Z, Y, J, H, K) for the finest spatial scale of 0.004" per spaxel. We briefly discuss future development plans for the data reduction pipeline and quicklook software for the IRIS instrument suite.

  13. [Neuropathology of Natalizumab-Associated Progressive Multifocal Leukoencephalopathy].

    PubMed

    Kanda, Takashi

    2015-07-01

    The pathological findings of natalizumab-associated progressive multifocal leukoencephalopathy (PML) are reviewed. In addition to the classical pathology of PML including the presence of enlarged abnormal astrocytes, intranuclear inclusions mainly found within large swollen oligodendrocytes and abundant myelin-laden macrophages/microglia, massive perivascular and parenchymal mononuclear cell infiltration was observed. The latter pathologic picture is that of immune reconstitution inflammatory syndrome (IRIS), and most of these infiltrating cells are CD8-positive T cells. Because IRIS inevitably occurs after the cessation of natalizumab therapy due to the development of PML and subsequent plasma exchange, most of the published pathologic pictures of natalizumab-associated PML patients were a mixture of PML and PML-IRIS. PML-IRIS is also characterized by fewer oligodendroglial viral inclusions and fewer cells that are immunoreactive against anti-JCV antibodies. These findings suggest the effective removal of JCV after the return of normal immune-surveillance in the central nervous system, but clinicians should be aware that JCV elimination is not complete under the IRIS condition, and the immunosuppressive therapy against IRIS should be carefully performed. Mononuclear cell infiltration in natalizumab-associated PML-IRIS patients was much more prominent than that in HIV-associated PML-IRIS patients, reflecting the retained, even enhanced, systemic immunities in patients treated by natalizumab.

  14. Effect of Γ-aminobutyric acid on kidney injury induced by renal ischemia-reperfusion in male and female rats: Gender-related difference.

    PubMed

    Vafapour, Marzieh; Nematbakhsh, Mehdi; Monajemi, Ramesh; Mazaheri, Safoora; Talebi, Ardeshir; Talebi, Nahid; Shirdavani, Soheyla

    2015-01-01

    The most important cause of kidney injury is renal ischemia/reperfusion injury (IRI), which is gender-related. This study was designed to investigate the protective role of Γ-aminobutyric acid (GABA (against IRI in male and female rats. Thirty-six female and male wistar rats were assigned to six experimental groups. The IRI was induced by clamping renal vessels for 45 min then was performed reperfusion for 24 h. The group sex posed to IRI were pretreated with GABA and were compared with the control groups. Serum levels of creatinine and blood urea nitrogen, kidney weight, and kidney tissue damage score increased in the IRI alone groups, (P < 0.05), while GABA decreased these parameters in female significantly (P < 0.05), but not in male rats. Uterus weight decreased significantly in female rats treated with GABA. Testis weight did not alter in male rats. Serum level of nitrite and kidney level of malondialdehyde (MDA) had no significant change in both female and male rats. Kidney level of nitrite increased significantly in female rats experienced IRI and serum level of MDA increased significantly in males that were exposed to IRI (P < 0.05). GABA could ameliorate kidney injury induced by renal IRI in a gender dependent manner.

  15. Performance evaluation of wavelet-based face verification on a PDA recorded database

    NASA Astrophysics Data System (ADS)

    Sellahewa, Harin; Jassim, Sabah A.

    2006-05-01

    The rise of international terrorism and the rapid increase in fraud and identity theft has added urgency to the task of developing biometric-based person identification as a reliable alternative to conventional authentication methods. Human Identification based on face images is a tough challenge in comparison to identification based on fingerprints or Iris recognition. Yet, due to its unobtrusive nature, face recognition is the preferred method of identification for security related applications. The success of such systems will depend on the support of massive infrastructures. Current mobile communication devices (3G smart phones) and PDA's are equipped with a camera which can capture both still and streaming video clips and a touch sensitive display panel. Beside convenience, such devices provide an adequate secure infrastructure for sensitive & financial transactions, by protecting against fraud and repudiation while ensuring accountability. Biometric authentication systems for mobile devices would have obvious advantages in conflict scenarios when communication from beyond enemy lines is essential to save soldier and civilian life. In areas of conflict or disaster the luxury of fixed infrastructure is not available or destroyed. In this paper, we present a wavelet-based face verification scheme that have been specifically designed and implemented on a currently available PDA. We shall report on its performance on the benchmark audio-visual BANCA database and on a newly developed PDA recorded audio-visual database that take include indoor and outdoor recordings.

  16. In vivo analysis of the iris thickness by spectral domain optical coherence tomography.

    PubMed

    Invernizzi, Alessandro; Cigada, Mario; Savoldi, Luisa; Cavuto, Silvio; Fontana, Luigi; Cimino, Luca

    2014-09-01

    To assess the effectiveness of spectral domain optical coherence tomography (SD-OCT) in providing in vivo measurements of iris thickness in healthy and pathological subjects. 14 healthy volunteers and 14 patients with unilateral Fuchs' uveitis were enrolled in the study. The two groups were comparable for age, gender and race. Each subject underwent complete clinical examination and anterior segment SD-OCT imaging in both eyes. SD-OCT scans of the iris were performed following a cross-sectional pattern. Iris thickness values were obtained using a purposely developed software-based analysis of OCT images. Measurements were carried out twice by two trained independent operators to assess intraobserver and interobserver repeatability. Analysis of iris thickness was conducted in four main quadrants: superior, inferior, nasal and temporal. Iris thickness values from normal subjects were compared with the ones measured in the affected and fellow eyes of patients with Fuchs' uveitis. Iris thickness measurements showed good intraobserver and interobserver repeatability (intraclass correlation coefficient >0.971). Superior and temporal iris sectors showed respectively thickest and thinnest values in all groups. In healthy eyes, iris thickness ranged from 327.92±37.29 μm temporally to 405.25±48.49 μm superiorly. Iris thickness measurements in the affected eyes of Fuchs' uveitis patients ranged from 285.48±56.02 μm temporally to 376.12±60.97 μm superiorly. Multiple comparison analysis showed iris thickness values to be significantly lower in eyes affected by Fuchs' uveitis than both in fellow eyes (p<0.001) of the same patients and in healthy eyes (p=0.0074). SD-OCT is a suitable technique for iris thickness assessment. Thickness analysis must be carried out using a sectorial approach, taking into consideration anatomical variations existing between different iris regions. SD-OCT is a potentially useful tool for detecting iris thickness variations induced by pathological conditions such as Fuchs' uveitis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Sparse coding joint decision rule for ear print recognition

    NASA Astrophysics Data System (ADS)

    Guermoui, Mawloud; Melaab, Djamel; Mekhalfi, Mohamed Lamine

    2016-09-01

    Human ear recognition has been promoted as a profitable biometric over the past few years. With respect to other modalities, such as the face and iris, that have undergone a significant investigation in the literature, ear pattern is relatively still uncommon. We put forth a sparse coding-induced decision-making for ear recognition. It jointly involves the reconstruction residuals and the respective reconstruction coefficients pertaining to the input features (co-occurrence of adjacent local binary patterns) for a further fusion. We particularly show that combining both components (i.e., the residuals as well as the coefficients) yields better outcomes than the case when either of them is deemed singly. The proposed method has been evaluated on two benchmark datasets, namely IITD1 (125 subject) and IITD2 (221 subjects). The recognition rates of the suggested scheme amount for 99.5% and 98.95% for both datasets, respectively, which suggest that our method decently stands out against reference state-of-the-art methodologies. Furthermore, experiments conclude that the presented scheme manifests a promising robustness under large-scale occlusion scenarios.

  18. Comparison of eye imaging pattern recognition using neural network

    NASA Astrophysics Data System (ADS)

    Bukhari, W. M.; Syed A., M.; Nasir, M. N. M.; Sulaima, M. F.; Yahaya, M. S.

    2015-05-01

    The beauty of eye recognition system that it is used in automatic identifying and verifies a human weather from digital images or video source. There are various behaviors of the eye such as the color of the iris, size of pupil and shape of the eye. This study represents the analysis, design and implementation of a system for recognition of eye imaging. All the eye images that had been captured from the webcam in RGB format must through several techniques before it can be input for the pattern and recognition processes. The result shows that the final value of weight and bias after complete training 6 eye images for one subject is memorized by the neural network system and be the reference value of the weight and bias for the testing part. The target classifies to 5 different types for 5 subjects. The eye images can recognize the subject based on the target that had been set earlier during the training process. When the values between new eye image and the eye image in the database are almost equal, it is considered the eye image is matched.

  19. Assessment of IRI-2012, NeQuick-2 and IRI-Plas 2015 models with observed equatorial ionization anomaly in Africa during 2009 sudden stratospheric warming event

    NASA Astrophysics Data System (ADS)

    Bolaji, O. S.; Oyeyemi, E. O.; Adewale, A. O.; Wu, Q.; Okoh, D.; Doherty, P. H.; Kaka, R. O.; Abbas, M.; Owolabi, C.; Jidele, P. A.

    2017-11-01

    In Africa, we assessed the performance of all the three options of International Reference Ionosphere 2012, IRI-2012 (i.e. IRI-2001, IRI-2001COR and IRI-NeQuick), NeQuick-2 and IRI-Plas 2015 models prior to and during 2009 sudden stratospheric warming (SSW) event to predict equatorial ionization anomaly (EIA) crest locations and their magnitudes using total electron content (TEC) from experimental records of Global Positioning System (GPS). We confirmed that the IRI-Plas 2015 that appeared as the best compared to all of the models as regard prediction of the EIA crest locations in the northern hemisphere of Africa is due to discontinuities in the GPS data between ∼8° N and 22° N. As regard the predictions of EIA crest magnitudes and the location of EIA crests in the southern hemisphere of Africa, they are not present in all the models. The NeQuick-2 model does not have the capability to predict either the EIA crest location in the northern or southern hemisphere. The SSW effect on the low latitude was able to modify a single EIA crest to pre-noon and post noon EIA crests in the northern hemisphere during the SSW peak phase and significantly reduced the GPS TEC magnitudes over the hemispheres as well. These SSW effects and delays of plasma transportation to higher latitudes in GPS TEC were absent in all the models. For future improvements of IRI-2012, NeQuick-2 and IRI-Plas 2015 models, SSW conditions should be included in order to characterize the effect of lower atmosphere on the ionosphere. The EIA trough modeling is only present in IRI-2001COR and IRI-2001NeQuick options. In the middle latitude, all the model could not predict the location of highest TEC magnitudes found at RBAY (Richardsbay, South Africa).

  20. Upper Atmospheric Effects of the HF Active Auroral Research Program Ionospheric Research Instrument (HAARP IRI)

    DTIC Science & Technology

    1993-05-01

    RESEARCH INSTRUMENT ( HAARP IRI) V. Eccles R. Armstrong Mission Research Corporation One Tara Blvd Nashua, NH 03062-2801 May 1993 Scientific Report No...INSTRUMENT ( HAARP IRI) PR 2310 STA G3 WU BM6. AUTHOR(S) V. Eccles and R. Armstrong 7. PERFOR•IlNG ORGANIZATION NAME(S) AND AOORESS(ES) 8. PERFORMING...Because the HAARP (HF Active Auroral Research Program) facility is designed to mimic and investigate certain natural processes, a study of possible

  1. Potentiation of femtosecond laser intratissue refractive index shaping (IRIS) in the living cornea with sodium fluorescein.

    PubMed

    Nagy, Lana J; Ding, Li; Xu, Lisen; Knox, Wayne H; Huxlin, Krystel R

    2010-02-01

    To assess the effectiveness of intratissue refractive index shaping (IRIS) in living corneas and test the hypothesis that it can be enhanced by increasing the two-photon absorption (TPA) of the tissue. Three corneas were removed from adult cats and cut into six pieces, which were placed in preservative (Optisol-GS; Bausch & Lomb, Inc., Irvine, CA) containing 0%, 0.25%, 1%, 1.5%, or 2.5% sodium fluorescein (Na-Fl). An 800-nm Ti:Sapphire femtosecond laser with a 100-fs pulse duration and 80-MHz repetition rate was used to perform IRIS in each piece, creating several refractive index (RI) modification lines at different speeds (between 0.1 and 5 mm/s). The lines were 1 mum wide, 10 microm apart, and approximately 150 microm below the tissue surface. The RI change of each grating was measured using calibrated, differential interference contrast microscopy. TUNEL staining was performed to assess whether IRIS or Na-Fl doping causes cell death. Scanning at 0.1 mm/s changed the RI of undoped, living corneas by 0.005. In doped corneas, RI changes between 0.01 and 0.02 were reliably achieved with higher scanning speeds. The magnitude of RI changes attained was directly proportional to Na-Fl doping concentration and inversely proportional to the scanning speed used to create the gratings. IRIS can be efficiently performed in living corneal tissue. Increasing the TPA of the tissue with Na-Fl increased both the scanning speeds and the magnitude of RI changes in a dose-dependent manner. Ongoing studies are exploring the use of IRIS to alter the optical properties of corneal tissue in situ, over an extended period.

  2. Potentiation of Femtosecond Laser Intratissue Refractive Index Shaping (IRIS) in the Living Cornea with Sodium Fluorescein

    PubMed Central

    Nagy, Lana J.; Ding, Li; Xu, Lisen; Knox, Wayne H.

    2010-01-01

    Purpose. To assess the effectiveness of intratissue refractive index shaping (IRIS) in living corneas and test the hypothesis that it can be enhanced by increasing the two-photon absorption (TPA) of the tissue. Methods. Three corneas were removed from adult cats and cut into six pieces, which were placed in preservative (Optisol-GS; Bausch & Lomb, Inc., Irvine, CA) containing 0%, 0.25%, 1%, 1.5%, or 2.5% sodium fluorescein (Na-Fl). An 800-nm Ti:Sapphire femtosecond laser with a 100-fs pulse duration and 80-MHz repetition rate was used to perform IRIS in each piece, creating several refractive index (RI) modification lines at different speeds (between 0.1 and 5 mm/s). The lines were 1 μm wide, 10 μm apart, and ∼150 μm below the tissue surface. The RI change of each grating was measured using calibrated, differential interference contrast microscopy. TUNEL staining was performed to assess whether IRIS or Na-Fl doping causes cell death. Results. Scanning at 0.1 mm/s changed the RI of undoped, living corneas by 0.005. In doped corneas, RI changes between 0.01 and 0.02 were reliably achieved with higher scanning speeds. The magnitude of RI changes attained was directly proportional to Na-Fl doping concentration and inversely proportional to the scanning speed used to create the gratings. Conclusions. IRIS can be efficiently performed in living corneal tissue. Increasing the TPA of the tissue with Na-Fl increased both the scanning speeds and the magnitude of RI changes in a dose-dependent manner. Ongoing studies are exploring the use of IRIS to alter the optical properties of corneal tissue in situ, over an extended period. PMID:19815735

  3. Personal identification by eyes.

    PubMed

    Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana

    2011-09-01

    Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.

  4. Modulation of the neurological and vascular complications by grape seed extract in a rat model of spinal cord ischemia-reperfusion injury by downregulation of both osteopontin and cyclooxygenase-2.

    PubMed

    Sakr, Hussein F; Abbas, Amr M; Bin-Jaliah, Ismaeel

    2016-07-01

    In this study, we investigated the effects of grape seed extract (GSE) on the expression of osteopontin (OPN) and cyclooxygenase-2 (COX-2) in a rat model of spinal cord ischemia-reperfusion injury (SC-IRI). Fifty male rats were divided into 5 groups: control (CON); control + GSE (CON + GSE) (received GSE for 28 days); sham operated (Sham); IRI; and IRI + GSE. SC-IRI was induced by clamping the aorta just above the bifurcation for 45 min, and then the clamp was released for 48 h for reperfusion. IRI + GSE group received GSE for 28 days before SC-IRI. Sensory, motor, and placing/stepping reflex assessment was performed. Prostaglandin E2 (PGE2), thiobarbituric acid reactive substances (TBARs), and total antioxidant capacity (TAC) were measured in spinal cord homogenate. Immunohistochemical examination of the spinal cord for OPN and COX-2 were carried out. SC-IRI resulted in significant increase in plasma nitrite/nitrate level and spinal cord homogenate levels of TBARs and PGE2, and OPN and COX-2 expression with significant decrease in TAC. GSE improves the sensory and motor functions through decreasing OPN and COX-2 expression with reduction of oxidative stress parameters. We conclude a neuroprotective effect of GSE in SC-IRI through downregulating COX-2 and OPN expression plus its antioxidants effects.

  5. Analysis of Four Automated Urinalysis Systems Compared to Reference Methods.

    PubMed

    Bartosova, Kamila; Kubicek, Zdenek; Franekova, Janka; Louzensky, Gustav; Lavrikova, Petra; Jabor, Antonin

    2016-11-01

    The aim of this study was to compare four automated urinalysis systems: the Iris iQ200 Sprint (Iris Diagnostics, U.S.A.) combined with the Arkray AUTION MAX AX 4030, Iris + AUTION, Arkray AU 4050 (Arkray Global Business, Inc., Japan), Dirui FUS 2000 (Dirui Industrial Co., P.R.C.), and Menarini sediMAX (Menarini, Italy). Urine concentrations of protein and glucose (Iris, Dirui) were compared using reference quantitative analysis on an Abbott Architect c16000. Leukocytes, erythrocytes, epithelia, and casts (Iris, Arkray, Diuri, Menarini) were compared to urine sediment under reference light microscopy, Leica DM2000 (Leica Microsystems GmbH, Germany) with calibrated FastRead plates (Biosigma S.r.l., Italy), using both native and stained preparations. Total protein and glucose levels were measured using the Iris + AUTION system with borderline trueness, while the Dirui analysis revealed worse performances for the protein and glucose measurements. True classifications of leukocytes and erythrocytes were above 85% and 72%, respectively. Kappa statistics revealed a nearly perfect evaluation of leukocytes for all tested systems; the erythrocyte evaluation was nearly perfect for the Iris, Dirui and Arkray analyzers and substantial for the Menarini analyzer. The epithelia identification was connected to high false negativity (above 15%) in the Iris, Arkray, and Menarini analyses. False-negative casts were above 70% for all tested systems. The use of automated urinalysis demonstrated some weaknesses and should be checked by experienced laboratory staff using light microscopy.

  6. Vascular tumors of the iris in 45 patients: the 2009 Helen Keller Lecture.

    PubMed

    Shields, Jerry A; Bianciotto, Carlos; Kligman, Brad E; Shields, Carol L

    2010-09-01

    To report on a series of vascular tumors of the iris. Noncomparative case series. A retrospective medical record review of all patients with an iris vascular tumor was performed to identify the clinical features and develop a simple classification of these lesions. Included were demographics, clinical features, systemic associations, complications, management, and histopathology. There were 54 eyes in 45 patients with an iris vascular tumor. These were categorized as racemose hemangioma (41 eyes: 29 simple and 12 complex), cavernous hemangioma (3 eyes: 2 localized and 1 systemic), capillary hemangioma (1 eye, localized), varix (3 eyes, localized), and microhemangiomatosis (6 eyes, localized). The hemangiomas occurred in adults at a median age of 55 years, whereas capillary hemangioma occurred in infancy and cavernous hemangioma with systemic involvement occurred in a child. Of the 41 eyes with iris racemose hemangioma, none showed systemic involvement. Of all 54 eyes, transient hyphema was the main complication, found at some point in 30% or more of each affected eye except for iris capillary and racemose hemangioma. Surgical resection was necessary in 1 cavernous hemangioma and 1 varix. The remainder were managed with observation. There are now well-documented examples of iris racemose hemangioma, cavernous hemangioma, capillary hemangioma, varix, and microhemangiomatosis. Transient hyphema is the main complication. Observation is usually advised. Most are solitary lesions confined to the iris and some (cavernous hemangioma and microhemangiomatosis) can have important systemic associations.

  7. [Clinical key points. Gonioscopy].

    PubMed

    Hamard, P

    2007-05-01

    Gonioscopy should be performed in all patients with glaucoma or suspected of having glaucoma. Four points are systematically evaluated: the width of the angle, the degree of trabecular pigmentation, the iridotrabecular appositions or synechia, and the level of iris insertion and the shape of the peripheral iris profile.

  8. Dosimetric comparison between cone/Iris-based and InCise MLC-based CyberKnife plans for single and multiple brain metastases.

    PubMed

    Jang, Si Young; Lalonde, Ron; Ozhasoglu, Cihat; Burton, Steven; Heron, Dwight; Huq, M Saiful

    2016-09-08

    We performed an evaluation of the CyberKnife InCise MLC by comparing plan qualities for single and multiple brain lesions generated using the first version of InCise MLC, fixed cone, and Iris collimators. We also investigated differences in delivery efficiency among the three collimators. Twenty-four patients with single or multiple brain mets treated previously in our clinic on a CyberKnife M6 using cone/Iris collimators were selected for this study. Treatment plans were generated for all lesions using the InCise MLC. Number of monitor units, delivery time, target coverage, conformity index, and dose falloff were compared between MLC- and clinical cone/Iris-based plans. Statistical analysis was performed using the non-parametric Wilcoxon-Mann-Whitney signed-rank test. The planning accuracy of the MLC-based plans was validated using chamber and film measurements. The InCise MLC-based plans achieved mean dose and target coverage comparable to the cone/Iris-based plans. Although the conformity indices of the MLC-based plans were slightly higher than those of the cone/Iris-based plans, beam delivery time for the MLC-based plans was shorter by 30% ~ 40%. For smaller targets or cases with OARs located close to or abutting target volumes, MLC-based plans provided inferior dose conformity compared to cone/Iris-based plans. The QA results of MLC-based plans were within 5% absolute dose difference with over 90% gamma passing rate using 2%/2 mm gamma criteria. The first version of InCise MLC could be a useful delivery modality, especially for clinical situations for which delivery time is a limiting factor or for multitarget cases. © 2016 The Authors.

  9. Virtual cohorts and face-to-face recruitment: Strategies for cultivating the next generation of the IRIS Community

    NASA Astrophysics Data System (ADS)

    Hubenthal, M.; Wysession, M. E.; Aster, R. C.

    2009-12-01

    Since 1998, the IRIS Consortium REU program has facilitated research opportunities and career development for 71 undergraduate students to work with leaders in seismological research, travel to exciting locations for fieldwork, and engage in significant research for presentation and recognition at major professional conferences. A principal program goal is to encourage more students, representing a more diverse population, to choose careers in Earth science. Of the forty-six internship alumni that have completed their undergraduate degrees thus far, 85% have attained or are currently pursuing a graduate degree in a geoscience field and an additional 6% are working in a geoscience career with an undergraduate degree. The IRIS Consortium’s program differs from traditional REUs in that students are hosted at IRIS member institutions that are geographically distributed. To capture the sprit of a traditional REU cohort, IRIS has developed and refined a model that bonds students into a cohort. Key to the model are: a) research projects that have a common focus within seismology, b) a weeklong orientation where students get to know one another, share common experiences and establish a “social presence” with the other interns, c) a cyber infrastructure to maintain their connectedness in a way that enables both learning and collaboration, d) an alumni mentor that supports the interns and serves both as a role model and an unbiased and experienced third-party to the mentor/mentee relationship, and e) an alumni reception, and scientific presentation, at the annual Fall AGU Meeting to reconnect and share experiences. Through their virtual community interns offer each other assistance, share ideas, ask questions, and relate life experiences while conducting their own unique research. In addition to developing a model for encouraging virtual cohorts, IRIS has also carefully examined recruitment strategies to increase and diversify the applicant pool. Based on applicant surveys we believe that the best method to advertise REU programs has shifted away from the traditional and expensive hardcopy fliers tacked to bulletin board in the halls of science departments. Instead we have found that the two most common methods for students to learn about the program were by visiting the IRIS website to view video clips or slideshow presentations and via personal notification/encouragement from faculty or staff at their institutions. The importance of personal notification was even more pronounced for applicants from minority serving institutions. Given the importance both the web and faculty advising in encouraging students to apply, the IRIS REU has adopted the following three recruitment strategies: 1) Engage students through the website by providing access to traditional text and photos, narrated video clips and other media, as well as links to previous intern’s blogs, 2) Empower and encourage faculty to recruit students by providing resources for easy use in classes such as annotated slideshows and narrated videos, and 3) Reach out to minority students personally through a speaker series featuring minority alumni of the IRIS REU program.

  10. Cardiac-Specific SOCS3 Deletion Prevents In Vivo Myocardial Ischemia Reperfusion Injury through Sustained Activation of Cardioprotective Signaling Molecules.

    PubMed

    Nagata, Takanobu; Yasukawa, Hideo; Kyogoku, Sachiko; Oba, Toyoharu; Takahashi, Jinya; Nohara, Shoichiro; Minami, Tomoko; Mawatari, Kazutoshi; Sugi, Yusuke; Shimozono, Koutatsu; Pradervand, Sylvain; Hoshijima, Masahiko; Aoki, Hiroki; Fukumoto, Yoshihiro; Imaizumi, Tsutomu

    2015-01-01

    Myocardial ischemia reperfusion injury (IRI) adversely affects cardiac performance and the prognosis of patients with acute myocardial infarction. Although myocardial signal transducer and activator of transcription (STAT) 3 is potently cardioprotective during IRI, the inhibitory mechanism responsible for its activation is largely unknown. The present study aimed to investigate the role of the myocardial suppressor of cytokine signaling (SOCS)-3, an intrinsic negative feedback regulator of the Janus kinase (JAK)-STAT signaling pathway, in the development of myocardial IRI. Myocardial IRI was induced in mice by ligating the left anterior descending coronary artery for 1 h, followed by different reperfusion times. One hour after reperfusion, the rapid expression of JAK-STAT-activating cytokines was observed. We precisely evaluated the phosphorylation of cardioprotective signaling molecules and the expression of SOCS3 during IRI and then induced myocardial IRI in wild-type and cardiac-specific SOCS3 knockout mice (SOCS3-CKO). The activation of STAT3, AKT, and ERK1/2 rapidly peaked and promptly decreased during IRI. This decrease correlated with the induction of SOCS3 expression up to 24 h after IRI in wild-type mice. The infarct size 24 h after reperfusion was significantly reduced in SOCS3-CKO compared with wild-type mice. In SOCS3-CKO mice, STAT3, AKT, and ERK1/2 phosphorylation was sustained, myocardial apoptosis was prevented, and the expression of anti-apoptotic Bcl-2 family member myeloid cell leukemia-1 (Mcl-1) was augmented. Cardiac-specific SOCS3 deletion led to the sustained activation of cardioprotective signaling molecules including and prevented myocardial apoptosis and injury during IRI. Our findings suggest that SOCS3 may represent a key factor that exacerbates the development of myocardial IRI.

  11. Cardiac-Specific SOCS3 Deletion Prevents In Vivo Myocardial Ischemia Reperfusion Injury through Sustained Activation of Cardioprotective Signaling Molecules

    PubMed Central

    Nagata, Takanobu; Yasukawa, Hideo; Kyogoku, Sachiko; Oba, Toyoharu; Takahashi, Jinya; Nohara, Shoichiro; Minami, Tomoko; Mawatari, Kazutoshi; Sugi, Yusuke; Shimozono, Koutatsu; Pradervand, Sylvain; Hoshijima, Masahiko; Aoki, Hiroki; Fukumoto, Yoshihiro; Imaizumi, Tsutomu

    2015-01-01

    Myocardial ischemia reperfusion injury (IRI) adversely affects cardiac performance and the prognosis of patients with acute myocardial infarction. Although myocardial signal transducer and activator of transcription (STAT) 3 is potently cardioprotective during IRI, the inhibitory mechanism responsible for its activation is largely unknown. The present study aimed to investigate the role of the myocardial suppressor of cytokine signaling (SOCS)-3, an intrinsic negative feedback regulator of the Janus kinase (JAK)-STAT signaling pathway, in the development of myocardial IRI. Myocardial IRI was induced in mice by ligating the left anterior descending coronary artery for 1 h, followed by different reperfusion times. One hour after reperfusion, the rapid expression of JAK-STAT–activating cytokines was observed. We precisely evaluated the phosphorylation of cardioprotective signaling molecules and the expression of SOCS3 during IRI and then induced myocardial IRI in wild-type and cardiac-specific SOCS3 knockout mice (SOCS3-CKO). The activation of STAT3, AKT, and ERK1/2 rapidly peaked and promptly decreased during IRI. This decrease correlated with the induction of SOCS3 expression up to 24 h after IRI in wild-type mice. The infarct size 24 h after reperfusion was significantly reduced in SOCS3-CKO compared with wild-type mice. In SOCS3-CKO mice, STAT3, AKT, and ERK1/2 phosphorylation was sustained, myocardial apoptosis was prevented, and the expression of anti-apoptotic Bcl-2 family member myeloid cell leukemia-1 (Mcl-1) was augmented. Cardiac-specific SOCS3 deletion led to the sustained activation of cardioprotective signaling molecules including and prevented myocardial apoptosis and injury during IRI. Our findings suggest that SOCS3 may represent a key factor that exacerbates the development of myocardial IRI. PMID:26010537

  12. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study.

    PubMed

    Roberts, Philipp K; Goldstein, Debra A; Fawzi, Amani A

    2017-08-01

    Purpose/Aim of the study: To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the "eyes at risk" group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI.

  13. Anterior Segment Optical Coherence Tomography Angiography for Identification of Iris Vasculature and Staging of Iris Neovascularization: A Pilot Study

    PubMed Central

    Roberts, Philipp K.; Goldstein, Debra A.; Fawzi, Amani A.

    2017-01-01

    Purpose/Aim of the study To assess the ability of optical coherence tomographic angiography (OCTA) to visualize the normal iris vasculature as well as neovascularization of the iris (NVI). Materials and Methods Study participants with healthy eyes, patients at risk of NVI development and patients with active or regressed NVI were consecutively included in this cross-sectional observational study. Imaging was performed using a commercially available OCTA system (RTVue- XR Avanti, Optovue Inc., Fremont, CA, USA). Abnormal iris vessels were graded on OCTA according to a modified clinical staging system and compared to slitlamp and gonioscopic findings. Results Fifty eyes of 26 study participants (16 healthy eyes, 19 eyes at risk, 15 eyes with different stages of NVI) were imaged using OCTA. In 11 out of 16 healthy eyes (69%) with light or moderately dark iris pigmentation, we observed physiological, radially aligned iris vasculature on OCTA imaging, which could not be visualized in five eyes (31%) with darkly pigmented irides. One eye in the “eyes at risk” group was diagnosed with NVI based on OCTA, which was not observed clinically. Fifteen eyes with clinically active or regressed NVI were imaged. Different stages of NVI could be differentiated by OCTA, corresponding well to an established clinical grading system. Four eyes showed regressed NVI by OCTA, not seen clinically, and were graded as a newly defined stage 4. Conclusions This pilot clinical study showed that OCTA for imaging of the iris vasculature in health and disease is highly dependent on iris pigmentation. Fine, clinically invisible iris vessels can be visualized by OCTA in the very early stages as well as in the regressed stage of NVI. PMID:28441067

  14. The IRIS-GUS Shuttle Borne Upper Stage System

    NASA Technical Reports Server (NTRS)

    Tooley, Craig; Houghton, Martin; Bussolino, Luigi; Connors, Paul; Broudeur, Steve (Technical Monitor)

    2002-01-01

    This paper describes the Italian Research Interim Stage - Gyroscopic Upper Stage (IRIS-GUS) upper stage system that will be used to launch NASA's Triana Observatory from the Space Shuttle. Triana is a pathfinder earth science mission being executed on rapid schedule and small budget, therefore the mission's upper stage solution had to be a system that could be fielded quickly at relatively low cost and risk. The building of the IRIS-GUS system wa necessary because NASA lost the capability to launch moderately sized upper stage missions fro the Space Shuttle when the PAM-D system was retired. The IRIS-GUS system restores this capability. The resulting system is a hybrid which mates the existing, flight proven IRIS (Italian Research Interim Stage) airborne support equipment to a new upper stage, the Gyroscopic Upper Stage (GUS) built by the GSFC for Triana. Although a new system, the GUS exploits flight proven hardware and design approaches in most subsystems, in some cases implementing proven design approaches with state-of-the-art electronics. This paper describes the IRIS-GUS upper stage system elements, performance capabilities, and payload interfaces.

  15. A Field Study of an Iris Identification System

    DTIC Science & Technology

    2008-05-01

    conducted a field trial of a commercial iris identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in...identification scanner at the US Navy Fleet Numerical Meterology and Oceanography Center (FNMOC) in Mon- terey, CA. Scans were performed by US military guards

  16. Correlation peak analysis applied to a sequence of images using two different filters for eye tracking model

    NASA Astrophysics Data System (ADS)

    Patrón, Verónica A.; Álvarez Borrego, Josué; Coronel Beltrán, Ángel

    2015-09-01

    Eye tracking has many useful applications that range from biometrics to face recognition and human-computer interaction. The analysis of the characteristics of the eyes has become one of the methods to accomplish the location of the eyes and the tracking of the point of gaze. Characteristics such as the contrast between the iris and the sclera, the shape, and distribution of colors and dark/light zones in the area are the starting point for these analyses. In this work, the focus will be on the contrast between the iris and the sclera, performing a correlation in the frequency domain. The images are acquired with an ordinary camera, which with were taken images of thirty-one volunteers. The reference image is an image of the subjects looking to a point in front of them at 0° angle. Then sequences of images are taken with the subject looking at different angles. These images are processed in MATLAB, obtaining the maximum correlation peak for each image, using two different filters. Each filter were analyzed and then one was selected, which is the filter that gives the best performance in terms of the utility of the data, which is displayed in graphs that shows the decay of the correlation peak as the eye moves progressively at different angle. This data will be used to obtain a mathematical model or function that establishes a relationship between the angle of vision (AOV) and the maximum correlation peak (MCP). This model will be tested using different input images from other subject not contained in the initial database, being able to predict angle of vision using the maximum correlation peak data.

  17. The Effect of Decomposition on the Efficacy of Biometrics for Positive Identification.

    PubMed

    Sauerwein, Kelly; Saul, Tiffany B; Steadman, Dawnie Wolfe; Boehnen, Chris B

    2017-11-01

    Biometrics, unique measurable physiological and behavioral characteristics, are used to identify individuals in a variety of scenarios, including forensic investigations. However, data on the longevity of these indicators are incomplete. This study demonstrated that iris and fingerprint biometric data can be obtained up to four days postmortem in warmer seasons and 50 + days in the winter. It has been generally believed, but never studied, that iris recognition is only obtainable within the first 24 hours after death. However, this study showed that they remain viable for longer (2-34 days) depending upon the environmental conditions. Temperature, precipitation, insects, and scavenger activity were the primary factors affecting the retention of biometrics in decomposing human remains. While this study is an initial step in determining the utility of physiological biometrics across postmortem time, biometric research has the potential to make important contributions to human identification and the law enforcement, military, and medicolegal communities. © 2017 American Academy of Forensic Sciences.

  18. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System.

    PubMed

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-05-25

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction ( p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant ( p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.

  19. Excimer Laser Surgery: Biometrical Iris Eye Recognition with Cyclorotational Control Eye Tracker System

    PubMed Central

    Pajic, Bojan; Cvejic, Zeljka; Mijatovic, Zoran; Indjin, Dragan; Mueller, Joerg

    2017-01-01

    A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking—especially in the treatment of astigmatisms in corneal refractive Excimer laser correction—concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction (p < 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from −14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant (p < 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments. PMID:28587100

  20. [Correction of aphakia with the implantation of the retropupillary iris clip intraocular artificial lens].

    PubMed

    Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós

    2017-01-01

    The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.

  1. Clinical case definition and manifestations of paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome.

    PubMed

    Manosuthi, Weerawat; Van Tieu, Hong; Mankatitham, Wiroj; Lueangniyomkul, Aroon; Ananworanich, Jintanat; Avihingsanon, Anchalee; Siangphoe, Umaporn; Klongugkara, Sukonsri; Likanonsakul, Sirirat; Thawornwan, Unchana; Suntisuklappon, Bussakorn; Sungkanuparph, Somnuek

    2009-11-27

    The International Network for the Study of HIV-associated IRIS (INSHI) recently published criteria for tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) diagnosis. The performance of this definition and clinical manifestations of TB-IRIS were studied. Antiretroviral therapy-naive HIV/TB Thai patients receiving antituberculous therapy were enrolled during 2006-2007 and prospectively followed through 24 weeks of antiretroviral therapy. Patients were defined as having paradoxical TB-IRIS if they fulfilled the 'study definition' by French 2004 and were confirmed by an external reviewer. All were later compared by the classification according to 'INSHI-2008'. For the 126 patients, median baseline CD4 cell count was 43 cells/microl and HIV-1 RNA was 5.9 log(10) Y copies/ml. Seventy-three (58%) had extrapulmonary/disseminated TB. Twenty-two (18%) and 21 (17%) fulfilled TB-IRIS criteria according to the study definition and INSHI-2008 definition, respectively. Two (2%) were diagnosed by study definition only and one (1%) by INSHI-2008 definition only. Twenty (16%) were concordantly diagnosed by both definitions and 103 (82%) were consistently negative. Eighteen (82%) had worsening of a preexisting site, whereas four (18%) had TB-IRIS in a new location. Lymph node enlargement (73%) and fever (59%) were common in TB-IRIS. Sensitivity and specificity of INSHI-2008 was 91% (95% confidence interval, 72-98%) and 99% (95% confidence interval, 95-99.8%), respectively. Positive predictive value was 95% and negative predictive value was 98%. By multivariate analysis, factors predicting TB-IRIS were extrapulmonary TB (odds ratio, 8.63) and disseminated TB (odds ratio, 4.17). There was high concordance between the INSHI-2008 and French 2004 definition for TB-IRIS diagnosis in HIV/TB patients with relatively high rate of paradoxical TB-IRIS. This suggests that lack of HIV-1 RNA and CD4 cell count monitoring does not impede the ability to diagnose TB-IRIS.

  2. Comparison of COSMIC measurements with the IRI-2007 model over the eastern Mediterranean region.

    PubMed

    Vryonides, P; Haralambous, H

    2013-05-01

    This paper presents a comparison of the International Reference Ionosphere (IRI-2007) model over the eastern Mediterranean region with peak ionospheric characteristics (foF2-hmF2) and electron density profiles measured by FORMOSAT-3/COSMIC satellites in terms of GPS radio occultation technique and the Cyprus digisonde. In the absence of systematic ionosonde measurements over this area, COSMIC measurements provide an opportunity to perform such a study by considering observations for year 2010 to investigate the behaviour of the IRI-2007 model over the eastern Mediterranean area.

  3. The quiet and disturbed time performance of the IRI 2012 within 90°-130°E longitude sector during solar cycle 24

    NASA Astrophysics Data System (ADS)

    Bhuyan, Pradip; Yokoyama, Tatsuhiro; Supnithi, Pornchai; Kalita, Bitap Raj; Wang, Kehe; Komolmis, Tharadol; Yatini, Clara

    2016-07-01

    The performance of the IRI 2012 model is examined for the double peaked solar cycle 24 in the low latitude region of 90-130oE longitude in the context of the global longitudinal wave number four structure (WN4). The monthly mean values of the foF2 and the hmF2(if available) measurements at low and low mid-latitude stations Dibrugarh (27.5°N, 95°E), Hainan (19.2°N,109.7°E),Okinawa (26.5°N,128°E) and Cocos Island (12.2°S,96.8°E) during quiet times and Dibrugarh (27.5°N, 95°E), Chiang Mai (18.76°N,98.93°E), Chumphon (10.72°N,99.37°E), Kototabang (0.2°S,100.32°E) and Cocos Island (12.2°S,96.8°E ) during the disturbed days of a severe geomagnetic storm are investigated. These stations are located under the strongest peak of the longitudinal WN4 structure in NmF2 along 90-130°E longitudes. The IRI is quite successful in predicting the seasonal averages of NmF2 over this region except in the equinox afternoon period where IRI underestimates the NmF2 in low latitudes. When the monthly mean measured data is compared with IRI, the difference between the IRI model predictions and the measurements are found to follow a systematic pattern. The IRI-2012 with CCIR options slightly underestimates foF2 over Dibrugarh in day time and overestimates in the night time. The amount of underestimation varies from month to month and also depends on the solar activity levels. The IRI also underestimated the day time hmF2 and overestimated the night time hmF2 over Dibrugarh. In case of Hainan, the IRI overestimates the NmF2 in the equinox months and generally in the afternoon to post sunset period. The model values are closer in the solstice than in the equinox. In Okinawa, the trend reverses and the IRI overestimates the NmF2 in the day time and underestimates in the night time. The IRI overestimated the day time hmF2 and underestimated the night time hmF2 over Okinawa. In case of Cocos Island which lies almost on the EIA anomaly region of the southern hemisphere, IRI underestimates the peak day time NmF2 in most months. The measurements are closer to the model values in the forenoon period and in the low solar activity period. The striking feature across all the stations is the IRI underestimation of the post sunset enhancement of NmF2 in low latitudes. During the severe geomagnetic storm of 17-18 March, 2015, the IRI was not able to replicate the inhibition of EIA on the next day i.e. 18 March as observed in the 100°E longitude.

  4. Importance of strategy in social media: getting the most out of your post

    NASA Astrophysics Data System (ADS)

    Bohon, W.; Sumy, D. F.

    2016-12-01

    Social media is playing an ever-increasing role in informal science education due to its broad and ubiquitous reach, low overhead costs and versatility. However, to fully capitalize on the educational potential and dissemination capabilities of social media platforms, science organizations with a social media presence must move forward with an effective strategy that clearly outlines their audience, goals, messaging, content and growth objectives. It is also imperative that organizations perform a regular, rigorous evaluation of social media platform performance and conduct user engagement surveys and that they utilize this information to improve online performance and engagement. Here, we examine the IRIS EPO Facebook and Twitter platforms before and after the adoption of a more formal and detailed social media strategy. Some of the most effective growth tools thus far have been the content posting schedule, content media type guidelines and periodic platform performance evaluation. We also examine the results of a user survey assessing the efficacy of the IRIS social media presence. In the 8 months since the implementation of the new, more rigorous social media strategy the IRIS Facebook page following has grown by more than 90% and the Twitter page following has increased by almost 75%. This is a significant increase in growth as compared to the preceding years, which corresponds to significant increase in reach (Figure 1). By implementing a defined strategy with clear goals, scientific organizations can fully harness the educational potential offered by social media networks. [Figure 1: Facebook provided metrics showing the reach of the IRIS EPO Facebook page between 7/21/2014 and 7/22/2016. Although there are spikes in post reach in 2015 corresponding to newsworthy earthquake events, a significant increase in sustained reach occurred beginning in Dec of 2105 when the IRIS social media strategy was implemented.

  5. Intestinal ischemia/reperfusion injury triggers activation of innate toll-like receptor 4 and adaptive chemokine programs.

    PubMed

    Watson, M J; Ke, B; Shen, X-D; Gao, F; Busuttil, R W; Kupiec-Weglinski, J W; Farmer, D G

    2008-12-01

    Ischemia/reperfusion injury (IRI) is a major problem in intestinal transplantation. Toll-like receptor 4 (TLR4) has been implicated as a possible link between the innate and adaptive immune systems, however little data exists regarding TLR4 in intestinal IRI. The goal of this study is to evaluate the involvement of TLR4 in intestinal IRI and to assess the effect on T cell related chemokine programs. C57BL6 mice underwent 100 minutes of warm intestinal ischemia by SMA clamping. Control WT mice underwent laparotomy without vascular occlusion. Separate survival and analysis groups were performed, and intestinal tissue was harvested at 1 hour, 2 hours, 4 hours, and 24 hours post-reperfusion. Analysis included histology, CD3 immunostaining, myeloperoxidase activity, Western blot, and PCR. Survival was significantly worse in the IRI group vs control (50% vs. 100%). IRI caused severe histopathological injury including mucosal erosions and villous congestion and hemorrhage. Myeloperoxidase activity increased in a time-dependent manner after IRI (2.71 0.25 at 1 hour, 2.92 0.25 at 2 hours, 4 0.16 at 4 hours, 5.1 0.25 at 24 hours vs 0.47 0.11 controls, P < .05). Protein expression of TLR4 followed by NF-kappaB was increased after IRI. Additionally, mRNA production of IP-10, MIP-2, MCP-1, and RANTES was increased at all time-points, as was mRNA for ICAM-1 and E-selectin. This study is the first to demonstrate increased expression of TLR4 and NF-kappaB after warm intestinal IRI. This detrimental cascade may be initiated by TLR4 via NF-kappaB signaling pathways, implicating TLR4 as a potential therapeutic target for the prevention of intestinal IRI.

  6. Ultrastructural analysis of the pigment dispersion syndrome in DBA/2J mice.

    PubMed

    Schraermeyer, Mareike; Schnichels, Sven; Julien, Sylvie; Heiduschka, Peter; Bartz-Schmidt, Karl-Ulrich; Schraermeyer, Ulrich

    2009-11-01

    To characterise ocular pigment abnormalities associated with iris atrophy in DBA/2J mice as a model for human pigment dispersion syndrome. Immunohistochemistry, electron and light microscopy were performed to examine the eyes of DBA/2J mice ranging in age from 2.5 to 18 months old. The focus of our study was the description of the ultrastructural modifications in the irides of DBA/2J mice. The DBA/2J mice presented modifications in the melanosomes in all the pigmented parts of the eye, including the retinal pigment epithelial cells and choroidal melanocytes of the ciliary pigment epithelium. The extracellular matrix of the iris stroma disappeared with ageing. Pigmented cells detached from the iris and migrated into the trabecular meshwork exclusively on the anterior iris surface. These cells were identified as macrophages by immunohistochemistry and electron microscopy. There was no evidence that melanocytes or iris pigment epithelial cells migrated into the trabecular meshwork, but they became more and more depigmented. The aqueous outflow was blocked by pigment-laden cells, but not by cellular debris or melanosomes. No substantial amount of extracellular melanosomes was observed. The morphology of melanosomes is aberrant in all pigment cells in the eyes of DBA/2J mice. We conclude that the disease process begins with the transfer of both immature melanosomes from the iris pigment epithelium (IPE) and melanocytes to macrophages, which subsequently migrate into the trabecular meshwork. Accumulating macrophages cause a blockade of the chamber angle. As the disease progresses, the IPE, melanocytes and iris stroma, including blood vessels, disappear, leading to iris atrophy. It is speculated that the loss of these pigment cells is partly caused by reduction of the iris stroma.

  7. Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health Study.

    PubMed

    Schuster, Alexander K; Fischer, Joachim E; Vossmerbaeumer, Urs

    2017-03-01

    Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of <-4 or >+3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 subjects served as emmetropic group (-0.5 ≤ x ≤+0.5 dioptres). Previous ocular surgery was exclusion criterion. Six hundred and sixty-eight eyes of 398 persons [292 male (76%); age range; 18-66 years] were included in the study. In the myopic group, 105 eyes had a concave iris configuration (26%), while in the hyperopic group, no eye had this configuration (0%) and in the emmetropic group five eyes (5%). Convex iris configuration was found in 96% of hyperopic, in 85% of the emmetropic and in 67% of the myopic eyes. There was an association between concave iris configuration and myopia, younger age and male gender, and with anterior chamber angle width. Spectral domain OCT images can be used for analysis of the iris structure and geometry. Our results are limited to the properties of the study population having an age range from 18 to 66 years and consisting mainly of men. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Multimodal fusion of polynomial classifiers for automatic person recgonition

    NASA Astrophysics Data System (ADS)

    Broun, Charles C.; Zhang, Xiaozheng

    2001-03-01

    With the prevalence of the information age, privacy and personalization are forefront in today's society. As such, biometrics are viewed as essential components of current evolving technological systems. Consumers demand unobtrusive and non-invasive approaches. In our previous work, we have demonstrated a speaker verification system that meets these criteria. However, there are additional constraints for fielded systems. The required recognition transactions are often performed in adverse environments and across diverse populations, necessitating robust solutions. There are two significant problem areas in current generation speaker verification systems. The first is the difficulty in acquiring clean audio signals in all environments without encumbering the user with a head- mounted close-talking microphone. Second, unimodal biometric systems do not work with a significant percentage of the population. To combat these issues, multimodal techniques are being investigated to improve system robustness to environmental conditions, as well as improve overall accuracy across the population. We propose a multi modal approach that builds on our current state-of-the-art speaker verification technology. In order to maintain the transparent nature of the speech interface, we focus on optical sensing technology to provide the additional modality-giving us an audio-visual person recognition system. For the audio domain, we use our existing speaker verification system. For the visual domain, we focus on lip motion. This is chosen, rather than static face or iris recognition, because it provides dynamic information about the individual. In addition, the lip dynamics can aid speech recognition to provide liveness testing. The visual processing method makes use of both color and edge information, combined within Markov random field MRF framework, to localize the lips. Geometric features are extracted and input to a polynomial classifier for the person recognition process. A late integration approach, based on a probabilistic model, is employed to combine the two modalities. The system is tested on the XM2VTS database combined with AWGN in the audio domain over a range of signal-to-noise ratios.

  9. Online Learning and Teacher Education: Knowledge Acquisition, Application Skills, and Reported Confidence

    ERIC Educational Resources Information Center

    IRIS Center, 2014

    2014-01-01

    This report presents two studies that demonstrate superior performance of college students after use of free, online instructional Modules, produced by the IRIS Center. When compared to traditional teacher education methods, IRIS Modules yield better outcomes in terms of knowledge acquisition, application skills, and confidence in the use of…

  10. Plasma alpha-tochopherol determined by HPLC in dogs at different stages of chronic kidney disease: a retrospective study.

    PubMed

    Lippi, Ilaria; Perondi, F; Meucci, V; Mannarini, C; Intorre, L; Guidi, G

    2017-09-01

    The aim of the present study was to investigate retrospectively the plasma concentration of alpha-tocopherol in dogs with naturally acquired chronic kidney disease (CKD), at different stages of severity. Forty dogs (CKD group) with different stages of CKD (IRIS 1 n=12, IRIS 2 n=8, IRIS 3 n=11, IRIS 4 n=9) and 20 clinically healthy dogs were considered. Plasma alpha-tocopherol was assessed in both groups through high performance liquid chromatography (HPLC). Dogs of CKD group showed significantly lower (p=0.0002) levels of plasma alpha-tocopherol compared with clinically healthy dogs. A significant difference (p<0.04) in the number of patients with plasma alpha-tocopherol > or ≤ 21.5 ppm was found in CKD patients at different stages of severity. No significant correlation between plasma levels of alpha-tocopherol and plasma creatinine was found. In the present study, dogs affected by spontaneous CKD showed significantly lower plasma concentrations of alpha-tocopherol compared with clinically healthy dogs. Plasma alpha-tocopherol deficiency seems to be more severe in IRIS stage 1 and 4, compared with IRIS stage 2 and 3. The finding of marked alpha-tocopherol deficiency in patients in IRIS stage 1 should encourage further studies on the early use of prescription renal diet and antioxidant in this group of patients.

  11. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.

    PubMed

    May, Matthias S; Wüst, Wolfgang; Brand, Michael; Stahl, Christian; Allmendinger, Thomas; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2011-07-01

    We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.

  12. Authentication, privacy, security can exploit brainwave by biomarker

    NASA Astrophysics Data System (ADS)

    Jenkins, Jeffrey; Sweet, Charles; Sweet, James; Noel, Steven; Szu, Harold

    2014-05-01

    We seek to augment the current Common Access Control (CAC) card and Personal Identification Number (PIN) verification systems with an additional layer of classified access biometrics. Among proven devices such as fingerprint readers and cameras that can sense the human eye's iris pattern, we introduced a number of users to a sequence of 'grandmother images', or emotionally evoked stimuli response images from other users, as well as one of their own, for the purpose of authentication. We performed testing and evaluation of the Authenticity Privacy and Security (APS) brainwave biometrics, similar to the internal organ of the human eye's iris which cannot easily be altered. `Aha' recognition through stimulus-response habituation can serve as a biomarker, similar to keystroke dynamics analysis for inter and intra key fluctuation time of a memorized PIN number (FIST). Using a non-tethered Electroencephalogram (EEG) wireless smartphone/pc monitor interface, we explore the appropriate stimuli-response biomarker present in DTAB low frequency group waves. Prior to login, the user is shown a series of images on a computer display. They have been primed to click their mouse when the image is presented. DTAB waves are collected with a wireless EEG and are sent via Smartphone to a cloud based processing infrastructure. There, we measure fluctuations in DTAB waves from a wireless, non-tethered, single node EEG device between the Personal Graphic Image Number (PGIN) stimulus image and the response time from an individual's mental performance baseline. Towards that goal, we describe an infrastructure that supports distributed verification for web-based EEG authentication. The performance of machine learning on the relative Power Spectral Density EEG data may uncover features required for subsequent access to web or media content. Our approach provides a scalable framework wrapped into a robust Neuro-Informatics toolkit, viable for use in the Biomedical and mental health communities, as well as numerous consumer applications.

  13. Plateau iris secondary to iridociliary cysts.

    PubMed

    Vila-Arteaga, J; Díaz-Céspedes, R A; Suriano, M M

    2015-11-01

    We present a case of plateau iris and glaucoma due to multiple unilateral iridociliary cysts. The patient was treated with iridotomy Nd: YAG laser and 360° iridoplasty, without achieving pressure control. Phacoemulsification improved the hypertension. Dynamic gonioscopy and OCT of the anterior chamber was also performed before and after treatment. Iridociliary cysts are a benign condition that can cause iris plateau configuration, and can produce a difficult to treat ocular hypertension. Cystotomy, peripheral iridoplasty, and other treatments have been proposed. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  14. An Effective 3D Ear Acquisition System

    PubMed Central

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  15. Biometric Challenges for Future Deployments: A Study of the Impact of Geography, Climate, Culture, and Social Conditions on the Effective Collection of Biometrics

    DTIC Science & Technology

    2011-04-01

    to iris or face recognition. In addition, breathing the dust is prevented with something covering the mouth , which will cause problems with face...headgear that “obscures the hair or hairline”. [58] One database of face images has images of people with and without scarves over their mouth . [59... Electronic Systems Magazine. Vol 19, Number 9, September 2004. [58] U.S. Department of State. How to Apply [for a Passport] in Person. [On-line

  16. An Effective 3D Ear Acquisition System.

    PubMed

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition.

  17. On the applicability of STDP-based learning mechanisms to spiking neuron network models

    NASA Astrophysics Data System (ADS)

    Sboev, A.; Vlasov, D.; Serenko, A.; Rybka, R.; Moloshnikov, I.

    2016-11-01

    The ways to creating practically effective method for spiking neuron networks learning, that would be appropriate for implementing in neuromorphic hardware and at the same time based on the biologically plausible plasticity rules, namely, on STDP, are discussed. The influence of the amount of correlation between input and output spike trains on the learnability by different STDP rules is evaluated. A usability of alternative combined learning schemes, involving artificial and spiking neuron models is demonstrated on the iris benchmark task and on the practical task of gender recognition.

  18. Extending the depth of field in a fixed focus lens using axial colour

    NASA Astrophysics Data System (ADS)

    Fitzgerald, Niamh; Dainty, Christopher; Goncharov, Alexander V.

    2017-11-01

    We propose a method of extending the depth of field (EDOF) of conventional lenses for a low cost iris recognition front-facing smartphone camera. Longitudinal chromatic aberration (LCA) can be induced in the lens by means of dual wavelength illumination. The EDOF region is then constructed from the sum of the adjacent depths of field from each wavelength illumination. The lens parameters can be found analytically with paraxial raytracing. The extended depth of field is dependant on the glass chosen and position of the near object point.

  19. Developing professional caregivers' empathy and emotional competencies through mindfulness-based stress reduction (MBSR): results of two proof-of-concept studies.

    PubMed

    Lamothe, Martin; McDuff, Pierre; Pastore, Yves D; Duval, Michel; Sultan, Serge

    2018-01-05

    To assess the feasibility and acceptability of a mindfulness-based stress reduction (MBSR)-based intervention and determine if the intervention is associated with a significant signal on empathy and emotional competencies. Two pre-post proof-of-concept studies. Participants were recruited at the University of Montreal's Psychology Department (Study 1) and the CHU Sainte-Justine Department of Hematology-Oncology (Study 2). Study 1: 12 students completed the 8-week programme (mean age 24, range 18-34). Study 2: 25 professionals completed the 8-week programme (mean age 48, range 27-63). Standard MBSR programme including 8-week mindfulness programme consisting of 8 consecutive weekly 2-hour sessions and a full-day silent retreat. Mindfulness as measured by the Mindful Attention Awareness Scale; empathy as measured by the Interpersonal Reactivity Index (IRI)'s Perspective Taking and Empathic Concern subscales; identification of one's own emotions and those of others as measured by the Profile of Emotional Competence (PEC)'s Identify my Emotions and Identify Others' Emotions subscales; emotional acceptance as measured by the Acceptance and Action Questionnaire-II (AAQ-II) and the Emotion Regulation Scale (ERQ)'s Expressive Suppression subscale; and recognition of emotions in others as measured by the Geneva Emotion Recognition Test (GERT). In both studies, retention rates (80%-81%) were acceptable. Participants who completed the programme improved on all measures except the PEC's Identify Others' Emotions and the IRI's Empathic Concern (Cohen's d median=0.92, range 45-1.72). In Study 2, favourable effects associated with the programme were maintained over 3 months on the PEC's Identify my Emotions, the AAQ-II, the ERQ's Expressive Suppression and the GERT. The programme was feasible and acceptable. It was associated with a significant signal on the following outcomes: perspective taking, the identification of one's own emotions and emotional acceptance, thus, justifying moving towards efficacy trials using these outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Performance evaluation of GIM-TEC assimilation of the IRI-Plas model at two equatorial stations in the American sector

    NASA Astrophysics Data System (ADS)

    Adebiyi, S. J.; Adebesin, B. O.; Ikubanni, S. O.; Joshua, B. W.

    2017-05-01

    Empirical models of the ionosphere, such as the International Reference Ionosphere (IRI) model, play a vital role in evaluating the environmental effect on the operation of space-based communication and navigation technologies. The IRI extended to Plasmasphere (IRI-Plas) model can be adjusted with external data to update its electron density profile while still maintaining the overall integrity of the model representations. In this paper, the performance of the total electron content (TEC) assimilation option of the IRI-Plas at two equatorial stations, Jicamarca, Peru (geographic: 12°S, 77°W, dip angle 0.8°) and Cachoeira Paulista, Brazil (Geographic: 22.7°S, 45°W, dip angle -26°), is examined during quiet and disturbed conditions. TEC, F2 layer critical frequency (foF2), and peak height (hmF2) predicted when the model is operated without external input were used as a baseline in our model evaluation. Results indicate that TEC predicted by the assimilation option generally produced smaller estimation errors compared to the "no extra input" option during quiet and disturbed conditions. Generally, the error is smaller at the equatorial trough than near the crest for both quiet and disturbed days. With assimilation option, there is a substantial improvement of storm time estimations when compared with quiet time predictions. The improvement is, however, independent on storm's severity. Furthermore, the modeled foF2 and hmF2 are generally poor with TEC assimilation, particularly the hmF2 prediction, at the two locations during both quiet and disturbed conditions. Consequently, IRI-Plas model assimilated with TEC value only may not be sufficient where more realistic instantaneous values of peak parameters are required.

  1. Evaluation of vocal acoustic and efficiency analysis parameters in medical students and academic teachers with use of iris and diagnoscope specialist software.

    PubMed

    Zielińska-Bliźniewska, Hanna; Sułkowski, Wiesław J; Pietkiewicz, Piotr; Miłoński, Jarosław; Mazurek, Agnieszka; Olszewski, Jurek

    2012-06-01

    The aim of this study was to compare the parameters of vocal acoustic and vocal efficiency analyses in medical students and academic teachers with use of the IRIS and DiagnoScope Specialist software and to evaluate their usefulness in prevention and certification of occupational disease. The study group comprised 40 women, including students and employees of the Military Medical Faculty, Medical University of Łodź. After informed consent had been obtained from the participant women, the primary medical history was taken, videolaryngoscopic and stroboscopic examinations were performed and diagnostic vocal acoustic analysis was carried out with the use of the IRIS and Diagno-Scope Specialist software. Based on the results of the performed measurements, the statistical analysis evidenced the compatibility between two software programs, IRIS and DiagnoScope Specialist, with the only exception of the F4 formant. The mean values of vocal acoustic parameters in medical students and academic teachers, obtained by means of the IRIS software, can be used as standards for the female population not yet developed by the producer. When using the DiagnoScope Specialist software, some mean values were higher and some lower than the standards specified by the producer. The study evidenced the compatibility between two measurement software programs, IRIS and DiagnoScope Specialist, except for the F4 formant. It should be noted that the later has advantage over the former since the standard values of vocal acoustic parameters have been worked out by the producer. Moreover, they only slightly departed from the values obtained in our study and may be useful in diagnostics of occupational voice disorders.

  2. Quantitative analysis of iris parameters in keratoconus patients using optical coherence tomography.

    PubMed

    Bonfadini, Gustavo; Arora, Karun; Vianna, Lucas M; Campos, Mauro; Friedman, David; Muñoz, Beatriz; Jun, Albert S

    2015-01-01

    To investigate the relationship between quantitative iris parameters and the presence of keratoconus. Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter) of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT). To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC) curves. Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC), which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used. In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.

  3. Noninvasive in vivo glucose sensing using an iris based technique

    NASA Astrophysics Data System (ADS)

    Webb, Anthony J.; Cameron, Brent D.

    2011-03-01

    Physiological glucose monitoring is important aspect in the treatment of individuals afflicted with diabetes mellitus. Although invasive techniques for glucose monitoring are widely available, it would be very beneficial to make such measurements in a noninvasive manner. In this study, a New Zealand White (NZW) rabbit animal model was utilized to evaluate a developed iris-based imaging technique for the in vivo measurement of physiological glucose concentration. The animals were anesthetized with isoflurane and an insulin/dextrose protocol was used to control blood glucose concentration. To further help restrict eye movement, a developed ocular fixation device was used. During the experimental time frame, near infrared illuminated iris images were acquired along with corresponding discrete blood glucose measurements taken with a handheld glucometer. Calibration was performed using an image based Partial Least Squares (PLS) technique. Independent validation was also performed to assess model performance along with Clarke Error Grid Analysis (CEGA). Initial validation results were promising and show that a high percentage of the predicted glucose concentrations are within 20% of the reference values.

  4. The influence of iris color on the pupillary light reflex.

    PubMed

    Bergamin, O; Schoetzau, A; Sugimoto, K; Zulauf, M

    1998-08-01

    This study was carried out to investigate the effect of iris color on the pupillary light reflex (PLR) in normal healthy volunteers. Pupil perimetry was performed on 50 healthy volunteers with the Octopus 1-2-3 automated perimeter. Within the 30-deg visual field, 33 test locations were investigated four times. Stimulus parameters were Goldmann size V (1.72 degrees), intensity 1632 cd/m2, stimulus time 200 ms, background illumination 0 cd/m2, and interstimulus interval 3 s. Pupillometric parameters studied were initial pupil size, amplitude (magnitude of pupillary contraction), latency time, contraction time, pre-PLR movement, contraction velocity, and redilation velocity. Pupillometric parameters were investigated by analysis of variance by the independent variables blue and brown irides. Iris color (blue vs brown) influenced statistically significantly (P < 0.05) amplitude (0.504 mm vs 0.594 mm), contraction time (401 ms vs 407 ms), contraction velocity (13.75 mm2/s vs 16.01 mm2/s), and redilation velocity (4.80 mm2/s vs 5.66 mm2/s). Iris color did not influence initial pupil size (4.78 mm vs 4.83 mm), latency time (520 mm vs 521 ms), and pre-PLR movement (0.328 mm2/s vs 0.325 mm2/s). Pupillary contraction amplitude and velocity depended on iris color, whereas pupil size and latency time were independent of iris color. Therefore, iris color might be considered when, evaluating pupillary movements in pupil perimetry.

  5. GNSS derived TEC data ingestion into IRI 2012

    NASA Astrophysics Data System (ADS)

    Migoya-Orué, Yenca; Nava, Bruno; Radicella, Sandro; Alazo-Cuartas, Katy

    2015-04-01

    Experimental vertical total electron content (VTEC) data given by Global Ionospheric Maps (GIM) has been ingested into the IRI version 2012, aiming to obtain grids of effective input parameter values that allow to minimize the difference between the experimental and modeled vertical TEC. Making use of the experience gained with the technique of model adaptation applied to NeQuick (Nava et al., 2005), it has been found possible to compute IRI world grids of effective ionosphere index parameters (IG). The IG grids thus obtained can be interpolated in space and time to calculate with IRI the 3D electron density at any location and also the TEC along any ground-to-satellite ray-path for a given epoch. In this study, the ingestion technique is presented and a posteriori validation, along with an assessment of the capability of the 'ingested' IRI to reproduce the ionosphere day-to-day foF2 variability during disturbed and quiet periods. The foF2 values retrieved are compared with data from about 20 worldwide ionosondes for selected periods of high (year 2000) and moderate to low solar activity (year 2006). It was found that the use of the ingestion scheme enhances the performance of the model when compared with its standard use based on solar activity drivers (R12 and F10.7), especially for high solar activity. As an example, the mean and standard deviation of the differences between experimental and reconstructed F2-peak values for April of year 2000 is 0.09 and 1.28 MHz for ingested IRI, compared to -0.81 and 1.27 MHz (IRI with R12 input) and -0.02 and 1.46 MHz (IRI with F10.7 input).

  6. Spontaneous anterior chamber hemorrhage from the iris: a unique cinematographic documentation.

    PubMed Central

    Welch, R B

    1980-01-01

    A 54-year-old white female was observed with an apparent spontaneous idiopathic anterior chamber hemorrhage from the pupillary border of the iris. This event was documented by cinematography. A review of the literature concerning anterior chamber hemorrhage is presented and reports of spontaneous hyphema enumerated. The relationship of the entity of pupillary vascular tufts to the present report are discussed and etiologic factors considered. It is apparent that closer scrutiny of the pupillary border should be performed and iris angiography obtained in a variety of eyes to delineate normal and abnormal variants. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 PMID:6167051

  7. Comparison of GPS-TEC variation during quiet and disturbed period using the Holt-Winter method and IRI-2012 model over Malaysia

    NASA Astrophysics Data System (ADS)

    Ahmed Ismail, Nouf Abd Emunim; Abdullah, Mardina; Hasbi, Alina Marie

    2016-07-01

    Total Electron Content (TEC) is the main parameter in the ionosphere that has significant effects on radio wave; it changes the speed and direction of the signal propagation, causing the delay of the Global Positioning System (GPS) signals. Therefore, it is crucial to validate the performance of the ionospheric model to reveal the variety of ionospheric behaviour during quiet and disturbed period. This research presents the performance evaluation of the statistical Holt-Winter method and IRI-2012 model using three topside electron density options: IRI-2001, IRI01-corr and NeQuick with the observed GPS-TEC during quiet and disturbed period. The GPS-TEC data were derived from the dual frequency GPS receiver at JUPEM (Department of Survey and Mapping Malaysia), from the UUMK station (north Peninsular Malaysia) at geographic coordinates of 6.46°N-100.50°E and geomagnetic coordinates of 3.32°S-172.99°E and TGPG station (south Peninsular Malaysia) at geographic coordinates of 1.36°N-104.10°E and geomagnetic coordinates of 8.43°S -176.53°E, during March of 2013. The maximum value of the GPS-TEC was at the post noon time at 17:00 LT and the minimum was in the early morning from 6:00-7:00 LT. During the quiet period, the maximum GPS-TEC at the UUMK station was 52 TECU while at the TGPG station, it was 60 TECU. During the disturbed period, when intense geomagnetic storm occurred on 17 March 2013, the maximum GPS-TEC recorded was 58 TECU and 65 TECU in UUMK and TGPG station, respectively. The diurnal hourly variation during the quiet period indicated that IRI-2001, IRI01-corr, and NeQuick had overestimation agreement during the day hours except for the time between 11:00-19:00 LT when IRI01-corr and NeQuick showed underestimation, while during 13:00-20:00 LT, IRI-2001 showed slight underestimation whereas the Holt-Winter method showed good agreement with GPS-TEC. During the disturbed period, IRI-2001 showed overestimation agreement for all hours, while the IRI01-corr and NeQuick model did not show any changes during the geomagnetic storm event. The Holt-Winter method showed better agreement with the GPS-TEC for both the UUMK and TGPG stations. The correlation between the observed and modeled GPS-TEC during the quiet and disturbed period for the UUMK station showed a slightly better correlation compared to the TGPG station. The Holt-Winter method showed good correlation of around 0.98 during the quiet period and 0.95 during the disturbed period, while IRI-2001, IRI01-corr, and NeQuick had comparatively lower correlation of around ≈ 0.8 during the quiet period and ≈ 0.7 during the disturbed period. Overall, this research concludes that the Holt-Winter method effectively the GPS-TEC with good correlation during the quiet and disturbed period in the equatorial region over Malaysia.

  8. Fluid and structure coupling analysis of the interaction between aqueous humor and iris.

    PubMed

    Wang, Wenjia; Qian, Xiuqing; Song, Hongfang; Zhang, Mindi; Liu, Zhicheng

    2016-12-28

    Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary block and angle closure. The nature of the interaction mechanism of iris deformation and aqueous humor fluid flow has not been fully understood and has been somewhat a controversial issue. The purpose here was to study the effect of IOP, localization, and temperature on the flow of the aqueous humor and the deformation of iris interacted by aqueous humor fluid flow. Based on mechanisms of aqueous physiology and fluid dynamics, 3D model of anterior chamber (AC) was constructed with the human anatomical parameters as a reference. A 3D idealized standard geometry of anterior segment of human eye was performed. Enlarge the size of the idealization geometry model 5 times to create a simulation device by using 3D printing technology. In this paper, particle image velocimetry technology is applied to measure the characteristic of fluid outflow in different inlet velocity based on the device. Numerically calculations were made by using ANSYS 14.0 Finite Element Analysis. Compare of the velocity distributions to confirm the validity of the model. The fluid structure interaction (FSI) analysis was carried out in the valid geometry model to study the aqueous flow and iris change. In this paper, the validity of the model is verified through computation and comparison. The results indicated that changes of gravity direction of model significantly affected the fluid dynamics parameters and the temperature distribution in anterior chamber. Increased pressure and the vertical position increase the velocity of the aqueous humor fluid flow, with the value increased of 0.015 and 0.035 mm/s. The results act on the iris showed that, gravity direction from horizontal to vertical decrease the equivalent stress in the normal IOP model, while almost invariably in the high IOP model. With the increased of the iris elasticity modulus, the equivalent strain and the total deformation of iris is decreased. The maximal value of equivalent strain of iris in high IOP model is higher than that of in normal IOP model. The maximum deformation of iris is lower in the high IOP model than in the normal IOP model. The valid model of idealization geometry of human eye could be helpful to study the relationship between localization, iris deformation and IOP. So far the FSI analysis was carried out in that idealization geometry model of anterior segment to study aqueous flow and iris change.

  9. Methylene blue attenuates ischemia--reperfusion injury in lung transplantation.

    PubMed

    Abreu, Marcus da Matta; Pazetti, Rogerio; Almeida, Francine Maria de; Correia, Aristides Tadeu; Parra, Edwin Roger; Silva, Laís Pereira da; Vieira, Rodolfo de Paula; Pêgo-Fernandes, Paulo Manuel; Jatene, Fabio Biscegli

    2014-12-01

    Ischemia-reperfusion injury (IRI) is one of the principal obstacles for the lung transplantation (LTx) success. Several strategies have been adopted to minimize the effects of IRI in lungs, including ex vivo conditioning of the grafts and the use of antioxidant drugs, such as methylene blue (MB). We hypothesized that MB could minimize the effects of IRI in a LTx rodent model. Forty rats were divided into four groups (n = 10) according to treatment (saline solution or MB) and graft cold ischemic time (3 or 6 h). All animals underwent unilateral LTx. Recipients received 2 mL of saline or MB intraperitoneally before transplantation. After 2 h of reperfusion, arterial blood and exhaled nitric oxide samples were collected and bronchoalveolar lavage performed. Then animals were euthanized, and histopathology analysis as well as cell counts and cytokine levels measurements in bronchoalveolar lavage fluid were performed. There was a significant decrease in exhaled nitric oxide, neutrophils, interleukin-6, and tumor necrosis factor-α in MB-treated animals. PaO2 and uric acid levels were higher in MB group. MB was able in attenuating IRI in this LTx model. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Assessment of IRI-2016 profile parameters over Indian low latitude station

    NASA Astrophysics Data System (ADS)

    Patel, Nilesh C.; Karia, Sheetal P.; Pathak, Kamlesh N.

    2018-05-01

    The present study reports the assessment of the bottom-side profile thickness (B0), shape (B1) and F2-peak height (hmF2) parameters IRI-2016 model over the Indian region by using digisonde observations. The digisonde data from a low latitude station Ahmedabad, (located at the crest of the northern equatorial anomaly) during three months June-2012, July-2012 and December-2012 are considered for this study. Simultaneous comparison is made on the performance of three different options `Gul-1987', `Bil-2000' and the `ABT-2009' for the bottom-side profile, three different options`AMTB2013 (AMT)', `SHU-2015 (SHU)', and `BSE-1979 (BSE)' for the hmF2 estimation in the latest available IRI-2016 to that obtained from digisonde measurements. Further, the diurnal characteristics of the B0 and B1 from digisonde measurements are also compared with those from the IRI-2016 model using the three different options.

  11. Global Real-Time Nowcasting of Ionosphere with Giro-Driven Assimilative IRI

    NASA Astrophysics Data System (ADS)

    Galkin, I. A.; Reinisch, B. W.; Huang, X. A.; Vesnin, A.; Bilitza, D.; Song, P.

    2014-12-01

    Real-time prediction of the ionosphere beyond its quiet-time median behavior has proved to be a great challenge: low-latency sensor data streams are scarce, and early comparisons conducted within the CEDAR ETI Assessment framework showed that, on average, the assimilative physics-based models perform on par with the long-term empirical predictions. This rather surprising result led to the formation of the Real-Time Task Force of the International Reference Ionosphere (IRI) science team in 2011, with a simple objective to develop a method for correcting the IRI long-term climatology definitions on the fly, i.e., in near real-time, using suitable observations. Three years later, a pilot version of the IRI-based Real-Time Assimilative Model "IRTAM" started its continuous operations at the Global Ionosphere Radio Observatory (GIRO) Data Center, using online feeds from the ionosondes contributing data to GIRO. The IRTAM version 0.1B builds and publishes every 15-minutes an updated "global weather" map of the peak density and height in the ionosphere, as well as a map of deviations from the classic IRI climate. Incidentally, the IRTAM verification and validation efforts shed light on the forecasting capabilities of the assimilative IRI extension, even though it has not yet involved external activity indicators. At the core of the assimilative computations, a Non-linear Error Compensation Technique for Associative Restoration (NECTAR) seeks agreement between IRI prediction and the 24-hour history of latest observations at GIRO sensor sites to produce the one map frame. The NECTAR first evaluates the diurnal harmonics of the observed deviations from the IRI climatology at each GIRO site to then independently compute the spatial maps for each diurnal harmonic. Thus obtained "corrective" coefficients of the spatial-diurnal expansion are added to the original IRI set of coefficients to obtain the IRTAM specification. We are intrigued by the IRTAM capability to glean ionospheric dynamics over no-data areas, and the potential for short-term forecasting.

  12. Performance of Solar Proxy Options of IRI-Plas Model for Equinox Seasons

    NASA Astrophysics Data System (ADS)

    Sezen, Umut; Gulyaeva, Tamara L.; Arikan, Feza

    2018-02-01

    International Reference Ionosphere (IRI) is the most acclaimed climatic model of the ionosphere. Since 2009, the range of the IRI model has been extended to the Global Positioning System (GPS) orbital height of 20,000 km in the plasmasphere. The new model, which is called IRI extended to Plasmasphere (IRI-Plas), can input not only the ionosonde foF2 and hmF2 but also the GPS-total electron content (TEC). IRI-Plas has been provided at www.ionolab.org, where online computation of ionospheric parameters is accomplished through a user-friendly interface. The solar proxies that are available in IRI-Plas can be listed as sunspot number (SSN1), SSN2, F10.7, global electron content (GEC), TEC, IG, Mg II, Lyman-α, and GEC_RZ. In this study, ionosonde foF2 data are compared with IRI-Plas foF2 values with the Consultative Committee International Radio (CCIR) and International Union of Radio Science (URSI) model choices for each solar proxy, with or without the GPS-TEC input for the equinox months of October 2011 and March 2015. It has been observed that the best fitting model choices in Root Mean Square (RMS) and Normalized RMS (NRMS) sense are the Jet Propulsion Laboratory global ionospheric maps-TEC input with Lyman-α solar proxy option for both months. The input of TEC definitely lowers the difference between the model and ionosonde foF2 values. The IG and Mg II solar proxies produce similar model foF2 values, and they usually are the second and third best fits to the ionosonde foF2 for the midlatitude ionosphere. In high-latitude regions, Jet Propulsion Laboratory global ionospheric map-TEC inputs to IRI-Plas with Lyman-α, GEC_RZ, and TEC solar proxies are the best choices. In equatorial region, the best fitting solar proxies are IG, Lyman-α, and Mg II.

  13. FAQs about IRIs.

    ERIC Educational Resources Information Center

    Paris, Scott G.; Carpenter, Robert D.

    2003-01-01

    Provides information about informal reading inventories (IRI), an early reading assessment. Explains what IRIs are; who should administer an IRI; when and how to administer an IRI; the reliability of data from IRIs; and the limitations of IRIs. (PM)

  14. U.S. Air Force School of Aerospace Medicine Laboratory Sampling and Analysis Guide

    DTIC Science & Technology

    2016-11-15

    valuable information during the environmental health risk assessment.  EPA Integrated Risk Information System (IRIS). IRIS is a human health assessment...information for more than 550 chemical substances containing information on human health effects that may result from exposure to various substances in the...Crystalyn E. Brown November 2016 Air Force Research Laboratory 711th Human Performance Wing School of Aerospace Medicine

  15. The IRIS Data Management Center: Enabling Access to Observational Time Series Spanning Decades

    NASA Astrophysics Data System (ADS)

    Ahern, T.; Benson, R.; Trabant, C.

    2009-04-01

    The Incorporated Research Institutions for Seismology (IRIS) is funded by the National Science Foundation (NSF) to operate the facilities to generate, archive, and distribute seismological data to research communities in the United States and internationally. The IRIS Data Management System (DMS) is responsible for the ingestion, archiving, curation and distribution of these data. The IRIS Data Management Center (DMC) manages data from more than 100 permanent seismic networks, hundreds of temporary seismic deployments as well as data from other geophysical observing networks such as magnetotelluric sensors, ocean bottom sensors, superconducting gravimeters, strainmeters, surface meteorological measurements, and in-situ atmospheric pressure measurements. The IRIS DMC has data from more than 20 different types of sensors. The IRIS DMC manages approximately 100 terabytes of primary observational data. These data are archived in multiple distributed storage systems that insure data availability independent of any single catastrophic failure. Storage systems include both RAID systems of greater than 100 terabytes as well as robotic tape robots of petabyte capacity. IRIS performs routine transcription of the data to new media and storage systems to insure the long-term viability of the scientific data. IRIS adheres to the OAIS Data Preservation Model in most cases. The IRIS data model requires the availability of metadata describing the characteristics and geographic location of sensors before data can be fully archived. IRIS works with the International Federation of Digital Seismographic Networks (FDSN) in the definition and evolution of the metadata. The metadata insures that the data remain useful to both current and future generations of earth scientists. Curation of the metadata and time series is one of the most important activities at the IRIS DMC. Data analysts and an automated quality assurance system monitor the quality of the incoming data. This insures data are of acceptably high quality. The formats and data structures used by the seismological community are esoteric. IRIS and its FDSN partners are developing web services that can transform the data holdings to structures that are more easily used by broader scientific communities. For instance, atmospheric scientists are interested in using global observations of microbarograph data but that community does not understand the methods of applying instrument corrections to the observations. Web processing services under development at IRIS will transform these data in a manner that allows direct use within such analysis tools as MATLAB® already in use by that community. By continuing to develop web-service based methods of data discovery and access, IRIS is enabling broader access to its data holdings. We currently support data discovery using many of the Open Geospatial Consortium (OGC) web mapping services. We are involved in portal technologies to support data discovery and distribution for all data from the EarthScope project. We are working with computer scientists at several universities including the University of Washington as part of a DataNet proposal and we intend to enhance metadata, further develop ontologies, develop a Registry Service to aid in the discovery of data sets and services, and in general improve the semantic interoperability of the data managed at the IRIS DMC. Finally IRIS has been identified as one of four scientific organizations that the External Research Division of Microsoft wants to work with in the development of web services and specifically with the development of a scientific workflow engine. More specific details of current and future developments at the IRIS DMC will be included in this presentation.

  16. Plateau Iris - Therapeutic options and functional results after treatment.

    PubMed

    Feraru, Crenguța; Bâlha, Andrei; Aursulesei, Victor; Filip, Andrei; Pantalon, Anca

    2017-01-01

    We present the therapeutic options and functional results in patients with plateau iris (syndrome or configuration) in consecutive case series. Material and method: Our study included newly diagnosed patients with acute angle closure by "plateau iris" (configuration or syndrome), between June 2016 and April 2017. Series of 8 consecutive patients met the inclusion criteria, all being females. All the patients underwent an individualized treatment according to the underlying mechanism and evolution. Functional results (visual acuity, IOP, topical medication) were reported in the current paper. Results: For 10 months, we diagnosed 14 eyes, from 9 patients with acute angle closure by Plateau Iris, distributed as it follows: 6 eyes with closed angle glaucoma (optic disk and visual field changes), 8 eyes with plateau iris syndrome and 2 eyes with plateau iris configuration. 7/ 8 patients were misdiagnosed with primary open angle glaucoma, whereas only one patient had the correct diagnosis of closed angle glaucoma and underwent peripheral laser iridotomy. As treatment options in our study, we recommended and performed argon laser peripheral iridoplasty + iridotomy in 10/ 14 eyes, cataract lens was extracted in 4 eyes and then replaced with PC-IOL, whereas 2 eyes required a filtering anti-glaucoma surgery (trabeculectomy + PI). 2 eyes from the same patient could not be treated as intended as the patient refused the treatment. In this unique case, Pilocarpine (4%) was temporarily indicated. Conclusion: Plateau iris represents a diagnostic trap, but based on a thorough gonioscopic examination and a good patient history, the right diagnosis can be made, all along with a correct therapeutic approach.

  17. Apples to apples: the origin and magnitude of differences in asbestos cancer risk estimates derived using varying protocols.

    PubMed

    Berman, D Wayne

    2011-08-01

    Given that new protocols for assessing asbestos-related cancer risk have recently been published, questions arise concerning how they compare to the "IRIS" protocol currently used by regulators. The newest protocols incorporate findings from 20 additional years of literature. Thus, differences between the IRIS and newer Berman and Crump protocols are examined to evaluate whether these protocols can be reconciled. Risks estimated by applying these protocols to real exposure data from both laboratory and field studies are also compared to assess the relative health protectiveness of each protocol. The reliability of risks estimated using the two protocols are compared by evaluating the degree with which each potentially reproduces the known epidemiology study risks. Results indicate that the IRIS and Berman and Crump protocols can be reconciled; while environment-specific variation within fiber type is apparently due primarily to size effects (not addressed by IRIS), the 10-fold (average) difference between amphibole asbestos risks estimated using each protocol is attributable to an arbitrary selection of the lowest of available mesothelioma potency factors in the IRIS protocol. Thus, the IRIS protocol may substantially underestimate risk when exposure is primarily to amphibole asbestos. Moreover, while the Berman and Crump protocol is more reliable than the IRIS protocol overall (especially for predicting amphibole risk), evidence is presented suggesting a new fiber-size-related adjustment to the Berman and Crump protocol may ultimately succeed in reconciling the entire epidemiology database. However, additional data need to be developed before the performance of the adjusted protocol can be fully validated. © 2011 Society for Risk Analysis.

  18. Iris features-based heart disease diagnosis by computer vision

    NASA Astrophysics Data System (ADS)

    Nguchu, Benedictor A.; Li, Li

    2017-07-01

    The study takes advantage of several new breakthroughs in computer vision technology to develop a new mid-irisbiomedical platform that processes iris image for early detection of heart-disease. Guaranteeing early detection of heart disease provides a possibility of having non-surgical treatment as suggested by biomedical researchers and associated institutions. However, our observation discovered that, a clinical practicable solution which could be both sensible and specific for early detection is still lacking. Due to this, the rate of majority vulnerable to death is highly increasing. The delayed diagnostic procedures, inefficiency, and complications of available methods are the other reasons for this catastrophe. Therefore, this research proposes the novel IFB (Iris Features Based) method for diagnosis of premature, and early stage heart disease. The method incorporates computer vision and iridology to obtain a robust, non-contact, nonradioactive, and cost-effective diagnostic tool. The method analyzes abnormal inherent weakness in tissues, change in color and patterns, of a specific region of iris that responds to impulses of heart organ as per Bernard Jensen-iris Chart. The changes in iris infer the presence of degenerative abnormalities in heart organ. These changes are precisely detected and analyzed by IFB method that includes, tensor-based-gradient(TBG), multi orientations gabor filters(GF), textural oriented features(TOF), and speed-up robust features(SURF). Kernel and Multi class oriented support vector machines classifiers are used for classifying normal and pathological iris features. Experimental results demonstrated that the proposed method, not only has better diagnostic performance, but also provides an insight for early detection of other diseases.

  19. Coastal and Inland Aquatic Data Products for the Hyperspectral Infrared Imager (HyspIRI)

    NASA Technical Reports Server (NTRS)

    Abelev, Andrei; Babin, Marcel; Bachmann, Charles; Bell, Thomas; Brando, Vittorio; Byrd, Kristin; Dekker , Arnold; Devred, Emmanuel; Forget, Marie-Helene; Goodman, James; hide

    2015-01-01

    The HyspIRI Aquatic Studies Group (HASG) has developed a conceptual list of data products for the HyspIRI mission to support aquatic remote sensing of coastal and inland waters. These data products were based on mission capabilities, characteristics, and expected performance. The topic of coastal and inland water remote sensing is very broad. Thus, this report focuses on aquatic data products to keep the scope of this document manageable. The HyspIRI mission requirements already include the global production of surface reflectance and temperature. Atmospheric correction and surface temperature algorithms, which are critical to aquatic remote sensing, are covered in other mission documents. Hence, these algorithms and their products were not evaluated in this report. In addition, terrestrial products (e.g., land use land cover, dune vegetation, and beach replenishment) were not considered. It is recognized that coastal studies are inherently interdisciplinary across aquatic and terrestrial disciplines. However, products supporting the latter are expected to already be evaluated by other components of the mission. The coastal and inland water data products that were identified by the HASG, covered six major environmental and ecological areas for scientific research and applications: wetlands, shoreline processes, the water surface, the water column, bathymetry and benthic cover types. Accordingly, each candidate product was evaluated for feasibility based on the HyspIRI mission characteristics and whether it was unique and relevant to the HyspIRI science objectives.

  20. Automatic coding and selection of causes of death: an adaptation of Iris software for using in Brazil.

    PubMed

    Martins, Renata Cristófani; Buchalla, Cassia Maria

    2015-01-01

    To prepare a dictionary in Portuguese for using in Iris and to evaluate its completeness for coding causes of death. Iniatially, a dictionary with all illness and injuries was created based on the International Classification of Diseases - tenth revision (ICD-10) codes. This dictionary was based on two sources: the electronic file of ICD-10 volume 1 and the data from Thesaurus of the International Classification of Primary Care (ICPC-2). Then, a death certificate sample from the Program of Improvement of Mortality Information in São Paulo (PRO-AIM) was coded manually and by Iris version V4.0.34, and the causes of death were compared. Whenever Iris was not able to code the causes of death, adjustments were made in the dictionary. Iris was able to code all causes of death in 94.4% death certificates, but only 50.6% were directly coded, without adjustments. Among death certificates that the software was unable to fully code, 89.2% had a diagnosis of external causes (chapter XX of ICD-10). This group of causes of death showed less agreement when comparing the coding by Iris to the manual one. The software performed well, but it needs adjustments and improvement in its dictionary. In the upcoming versions of the software, its developers are trying to solve the external causes of death problem.

  1. Aerobic metabolism on muscle contraction in porcine iris sphincter.

    PubMed

    Kanda, Hidenori; Kaneda, Takeharu; Kato, Asami; Yogo, Takuya; Harada, Yasuji; Hara, Yasusi; Urakawa, Norimoto; Shimizu, Kazumasa

    2016-12-01

    Eyes are supplied O 2 through the cornea and vessels of the retina and iris, which are tissues characterized by aerobic metabolism. Meanwhile, there are no reports on the association between iris sphincter contraction and aerobic metabolism. In this paper, we studied the aforementioned association. Eyes from adult pigs of either sex were obtained from a local abattoir. A muscle strip was connected to a transducer to isometrically record the tension. O 2 consumption was measured using a Clark-type polarograph connected to a biological oxygen monitor. Creatine phosphate (PCr) and adenosine triphosphate (ATP) contents were measured in the muscle strips by high-performance liquid chromatography (HPLC). Iris sphincter muscles were measured in resting, contractile or hypoxic phases. Contraction was induced by hyperosmotic 65 mM KCl (H-65K + ) or carbachol (CCh), and hypoxia was induced by aeration with N 2 instead of O 2 or by addition of sodium cyanide (NaCN). H-65K + - and CCh-induced muscle contraction, involved increasing O 2 consumption. Hypoxia and NaCN significantly decreased H-65K + - and CCh-induced muscle contraction and/or O 2 consumption and PCr contents. Our results suggest that the contractile behavior in porcine iris sphincter highly depends on mitogen oxidative metabolism.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Cynthia Lee

    There is a need in security systems to rapidly and accurately grant access of authorized personnel to a secure facility while denying access to unauthorized personnel. In many cases this role is filled by security personnel, which can be very costly. Systems that can perform this role autonomously without sacrificing accuracy or speed of throughput are very appealing. To address the issue of autonomous facility access through the use of technology, the idea of a ''secure portal'' is introduced. A secure portal is a defined zone where state-of-the-art technology can be implemented to grant secure area access or to allowmore » special privileges for an individual. Biometric technologies are of interest because they are generally more difficult to defeat than technologies such as badge swipe and keypad entry. The biometric technologies selected for this concept were facial and gait recognition. They were chosen since they require less user cooperation than other biometrics such as fingerprint, iris, and hand geometry and because they have the most potential for flexibility in deployment. The secure portal concept could be implemented within the boundaries of an entry area to a facility. As a person is approaching a badge and/or PIN portal, face and gait information can be gathered and processed. The biometric information could be fused for verification against the information that is gathered from the badge. This paper discusses a facial recognition technology that was developed for the purposes of providing high verification probabilities with low false alarm rates, which would be required of an autonomous entry control system. In particular, a 3-D facial recognition approach using Fisher Linear Discriminant Analysis is described. Gait recognition technology, based on Hidden Markov Models has been explored, but those results are not included in this paper. Fusion approaches for combining the results of the biometrics would be the next step in realizing the secure portal concept.« less

  3. Antigen-Specific Interferon-Gamma Responses and Innate Cytokine Balance in TB-IRIS

    PubMed Central

    Goovaerts, Odin; Jennes, Wim; Massinga-Loembé, Marguerite; Ceulemans, Ann; Worodria, William; Mayanja-Kizza, Harriet; Colebunders, Robert; Kestens, Luc

    2014-01-01

    Background Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients. Methods In a prospective cohort study of HIV-TB co-infected patients treated for TB before ART initiation, we compared 18 patients who developed TB-IRIS with 18 non-IRIS controls matched for age, sex and CD4 count. We analyzed IFNγ ELISpot responses to CMV, influenza, TB and LPS before ART and during TB-IRIS. CMV and LPS stimulated ELISpot supernatants were subsequently evaluated for production of IL-12p70, IL-6, TNFα and IL-10 by Luminex. Results Before ART, all responses were similar between TB-IRIS patients and non-IRIS controls. During TB-IRIS, IFNγ responses to TB and influenza antigens were comparable between TB-IRIS patients and non-IRIS controls, but responses to CMV and LPS remained significantly lower in TB-IRIS patients. Production of innate cytokines was similar between TB-IRIS patients and non-IRIS controls. However, upon LPS stimulation, IL-6/IL-10 and TNFα/IL-10 ratios were increased in TB-IRIS patients compared to non-IRIS controls. Conclusion TB-IRIS patients did not display excessive IFNγ responses to TB-antigens. In contrast, the reconstitution of CMV and LPS responses was delayed in the TB-IRIS group. For LPS, this was linked with a pro-inflammatory shift in the innate cytokine balance. These data are in support of a prominent role of the innate immune system in TB-IRIS. PMID:25415590

  4. Joint object and action recognition via fusion of partially observable surveillance imagery data

    NASA Astrophysics Data System (ADS)

    Shirkhodaie, Amir; Chan, Alex L.

    2017-05-01

    Partially observable group activities (POGA) occurring in confined spaces are epitomized by their limited observability of the objects and actions involved. In many POGA scenarios, different objects are being used by human operators for the conduct of various operations. In this paper, we describe the ontology of such as POGA in the context of In-Vehicle Group Activity (IVGA) recognition. Initially, we describe the virtue of ontology modeling in the context of IVGA and show how such an ontology and a priori knowledge about the classes of in-vehicle activities can be fused for inference of human actions that consequentially leads to understanding of human activity inside the confined space of a vehicle. In this paper, we treat the problem of "action-object" as a duality problem. We postulate a correlation between observed human actions and the object that is being utilized within those actions, and conversely, if an object being handled is recognized, we may be able to expect a number of actions that are likely to be performed on that object. In this study, we use partially observable human postural sequences to recognition actions. Inspired by convolutional neural networks (CNNs) learning capability, we present an architecture design using a new CNN model to learn "action-object" perception from surveillance videos. In this study, we apply a sequential Deep Hidden Markov Model (DHMM) as a post-processor to CNN to decode realized observations into recognized actions and activities. To generate the needed imagery data set for the training and testing of these new methods, we use the IRIS virtual simulation software to generate high-fidelity and dynamic animated scenarios that depict in-vehicle group activities under different operational contexts. The results of our comparative investigation are discussed and presented in detail.

  5. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    PubMed

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  6. Development of a PCR Diagnostic System for Iris yellow spot tospovirus in Quarantine

    PubMed Central

    Shin, Yong-Gil; Rho, Jae-Young

    2014-01-01

    Iris yellow spot virus (IYSV) is a plant pathogenic virus which has been reported to continuously occur in onion bulbs, allium field crops, seed crops, lisianthus, and irises. In South Korea, IYSV is a “controlled” virus that has not been reported, and inspection is performed when crops of the genus Iris are imported into South Korea. In this study, reverse-transcription polymerase chain reaction (RT-PCR) and nested PCR inspection methods, which can detect IYSV, from imported crops of the genus Iris at quarantine sites, were developed. In addition, a modified positive plasmid, which can be used as a positive control during inspection, was developed. This modified plasmid can facilitate a more accurate inspection by enabling the examination of a laboratory contamination in an inspection system. The inspection methods that were developed in this study are expected to contribute, through the prompt and accurate inspection of IYSV at quarantine sites to the plant quarantine in South Korea. PMID:25506310

  7. Region based feature extraction from non-cooperative iris images using triplet half-band filter bank

    NASA Astrophysics Data System (ADS)

    Barpanda, Soubhagya Sankar; Majhi, Banshidhar; Sa, Pankaj Kumar

    2015-09-01

    In this paper, we have proposed energy based features using a multi-resolution analysis (MRA) on iris template. The MRA is based on our suggested triplet half-band filter bank (THFB). The THFB derivation process is discussed in detail. The iris template is divided into six equispaced sub-templates and two level decomposition has been made to each sub-template using THFB except second one. The reason for discarding the second template is due to the fact that it mostly contains the noise due to eyelids, eyelashes, and occlusion due to segmentation failure. Subsequently, energy features are derived from the decomposed coefficients of each sub-template. The proposed feature has been experimented on standard databases like CASIAv3, UBIRISv1, and IITD and mostly on iris images which encounter a segmentation failure. Comparative analysis has been done with existing features based on Gabor transform, Fourier transform, and CDF 9/7 filter bank. The proposed scheme shows superior performance with respect to FAR, GAR and AUC.

  8. SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, C; Timmerman, R; Jiang, S

    Purpose: To evaluate the dosimetric impact on treatment planning for partial breast stereotactic irradiation using Cyberknife with MLC versus Iris Cone. Methods: Ten patients whom underwent lumpectomy for DCIS or stage I invasive non-lobular epithelial breast cancer were included in this study. All patients were previously treated on the Cyberknife using Iris cone with the prescription dose of 37.5Gy in 5 fractions covering at least 95% of PTV on our phase I SBRT 5 fraction partial breast irradiation trial. Retrospectively, treatment planning was performed and compared using the new Cyberknife M6 MLC system for each patient. Using the same contoursmore » and critical organ constraints for both MLC and Iris cone plans, the dose on target and critical organs were analyzed accordingly. Results: Dose to critical organs such as ipsilateral lung, contralateral lung, heart, skin, ipsilateral breast, and rib were analyzed, as well as conformity index and high dose spillage of the target area. In 9 of 10 patients, the MLC plans had less total ipsilateral breast volume encompassing the 50% prescription isodose (mean:22.3±8.2% MLC vs. 31.6±8.0 Iris, p=0.00014) .The MLC plans mean estimated treatment delivery time was significantly less than the Iris plans (51±3.9min vs. 56.2±9min, p=0.03) Both MLC and Iris cone plans were able to meet all dose constraints and there was no statistical difference between those dose constraints. Conclusion: Both MLC and Iris Cone can deliver conformal dose to a partial breast target and satisfy the dose constraints of critical organs. The new Cyberknife with MLC can deliver a more conformal dose in the lower dose region and spare more ipsilateral breast tissue to the 50% prescription isodose. The treatment time for partial breast SBRT plans was also reduced using MLC. Project receives research support from Accuray Inc.« less

  9. Methane attenuates retinal ischemia/reperfusion injury via anti-oxidative and anti-apoptotic pathways.

    PubMed

    Liu, Lin; Sun, Qinglei; Wang, Ruobing; Chen, Zeli; Wu, Jiangchun; Xia, Fangzhou; Fan, Xian-Qun

    2016-09-01

    Retinal ischemia/reperfusion injury (IRI) may cause incurable visual impairment due to neural regeneration limits. Methane was shown to exert a protective effect against IRI in many organs. This study aims to explore the possible protective effects of methane-rich saline against retinal IRI in rat. Retinal IRI was performed on the right eyes of male Sprague-Dawley rats, which were immediately injected intraperitoneally with methane-saturated saline (25ml/kg). At one week after surgery, the number of retinal ganglion cells (RGCs), total retinal thickness, visual function were measured by hematoxylin and eosin staining, FluoroGold anterograde labeling and flash visual evoked potentials. The levels of 8-hydroxy-2-deoxyguanosine (8-OHdG), 4-Hydroxy-2-nonenal (4-HNE), malondialdehyde (MDA), superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPx), caspase-3, caspase-9, B cell lymphoma/leukemia-2 (Bcl-2) and Bcl-2 associated X protein (Bax) in retinas were assessed by immunofluorescence staining, enzyme-linked immunosorbent assay and quantitative polymerase chain reaction. As expected, methane treatment significantly improved the retinal IRI-induced RGC loss, total retinal layer thinning and visual dysfunction. Moreover, methane treatment significantly reduced the levels of oxidative stress biomarkers (8-OHdG, 4-HNE, MDA) and increased the antioxidant enzyme activities (SOD, CAT, GPx) in the retinas with IRI. Meanwhile, methane treatment significantly increased the anti-apoptotic gene (Bcl-2) expression and decreased the pro-apoptotic gene (Bax) expression, accompanied by the suppression of caspase-3 and caspase-9 activity. Thus, these data demonstrated that methane can exert a neuroprotective role against retinal IRI through anti-oxidative and anti-apoptotic pathways. Copyright © 2016. Published by Elsevier B.V.

  10. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    PubMed

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  11. Comparison of Factors Associated With Occludable Angle Between American Caucasians and Ethnic Chinese

    PubMed Central

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-01-01

    Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992

  12. Measuring Medical Students' Empathy: Exploring the Underlying Constructs of and Associations Between Two Widely Used Self-Report Instruments in Five Countries.

    PubMed

    Costa, Patrício; de Carvalho-Filho, Marco Antonio; Schweller, Marcelo; Thiemann, Pia; Salgueira, Ana; Benson, John; Costa, Manuel João; Quince, Thelma

    2017-06-01

    Understanding medical student empathy is important to future patient care; however, the definition and development of clinical empathy remain unclear. The authors sought to examine the underlying constructs of two of the most widely used self-report instruments-Davis's Interpersonal Reactivity Index (IRI) and the Jefferson Scale of Empathy version for medical students (JSE-S)-plus, the distinctions and associations between these instruments. Between 2007 and 2014, the authors administered the IRI and JSE-S in three separate studies in five countries, (Brazil, Ireland, New Zealand, Portugal, and the United Kingdom). They collected data from 3,069 undergraduate medical students and performed exploratory factor analyses, correlation analyses, and multiple linear regression analyses. Exploratory factor analysis yielded identical results in each country, confirming the subscale structures of each instrument. Results of correlation analyses indicated significant but weak correlations (r = 0.313) between the total IRI and JSE-S scores. All intercorrelations of IRI and JSE-S subscale scores were statistically significant but weak (range r = -0.040 to 0.306). Multiple linear regression models revealed that the IRI subscales were weak predictors of all JSE-S subscale and total scores. The IRI subscales explained between 9.0% and 15.3% of variance for JSE-S subscales and 19.5% for JSE-S total score. The IRI and JSE-S are only weakly related, suggesting that they may measure different constructs. To better understand this distinction, more studies using both instruments and involving students at different stages in their medical education, as well as more longitudinal and qualitative studies, are needed.

  13. Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population.

    PubMed

    Invernizzi, Alessandro; Giardini, Piero; Cigada, Mario; Viola, Francesco; Staurenghi, Giovanni

    2015-07-01

    We analyzed by swept-source anterior segment optical coherence tomography (SS-ASOCT) the three-dimensional iris morphology in a Caucasian population, and correlated the findings with iris color, iris sectors, subject age, and sex. One eye each from consecutive healthy emmetropic (refractive spherical equivalent ± 3 diopters) volunteers were selected for the study. The enrolled eye underwent standardized anterior segment photography to assess iris color. Iris images were assessed by SS-ASOCT for volume, thickness, width, and pupil size. Sectoral variations of morphometric data among the superior, nasal, inferior, and temporal sectors were recorded. A total of 135 eyes from 57 males and 78 females, age 49 ± 17 years, fulfilled the inclusion criteria. All iris morphometric parameters varied significantly among the different sectors (all P < 0.0001). Iris total volume and thickness were significantly correlated with increasingly darker pigmentation (P < 0.0001, P = 0.0384, respectively). Neither width nor pupil diameter was influenced by iris color. Age did not affect iris volume or thickness; iris width increased and pupil diameter decreased with age (rs = 0.52, rs = -0.58, respectively). There was no effect of sex on iris volume, thickness, or pupil diameter; iris width was significantly greater in males (P = 0.007). Morphology of the iris varied by iris sector, and iris color was associated with differences in iris volume and thickness. Morphological parameter variations associated with iris color, sector, age, and sex can be used to identify pathological changes in suspect eyes. To be effective in clinical settings, construction of iris morphological databases for different ethnic and racial populations is essential.

  14. Gait biometrics under spoofing attacks: an experimental investigation

    NASA Astrophysics Data System (ADS)

    Hadid, Abdenour; Ghahramani, Mohammad; Kellokumpu, Vili; Feng, Xiaoyi; Bustard, John; Nixon, Mark

    2015-11-01

    Gait is a relatively biometric modality which has a precious advantage over other modalities, such as iris and voice, in that it can be easily captured from a distance. Although it has recently become a topic of great interest in biometric research, there has been little investigation into gait spoofing attacks where a person tries to imitate the clothing or walking style of someone else. We recently analyzed for the first time the effects of spoofing attacks on silhouette-based gait biometric systems and showed that it was indeed possible to spoof gait biometric systems by clothing impersonation and the deliberate selection of a target that has a similar build to the attacker. To gain deeper insight into the performance of current gait biometric systems under spoofing attacks, we provide a thorough investigation on how clothing can be used to spoof a target and evaluate the performance of two state-of-the-art recognition methods on a gait spoofing database recorded at the University of Southampton. Furthermore, we describe and evaluate an initial solution coping with gait spoofing attacks. The obtained results are very promising and point out interesting findings which can be used for future investigations.

  15. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients

    PubMed Central

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-01-01

    Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932

  16. Reduction of effective dose and organ dose to the eye lens in head MDCT using iterative image reconstruction and automatic tube current modulation.

    PubMed

    Ryska, Pavel; Kvasnicka, Tomas; Jandura, Jiri; Klzo, Ludovit; Grepl, Jakub; Zizka, Jan

    2014-06-01

    To compare the effective and eye lens radiation dose in helical MDCT brain examinations using automatic tube current modulation in conjunction with either standard filtered back projection (FBP) technique or iterative reconstruction in image space (IRIS). Of 400 adult brain MDCT examinations, 200 were performed using FBP and 200 using IRIS with the following parameters: tube voltage 120 kV, rotation period 1 second, pitch factor 0.55, automatic tube current modulation in both transverse and longitudinal planes with reference mAs 300 (FBP) and 200 (IRIS). Doses were calculated from CT dose index and dose length product values utilising ImPACT software; the organ dose to the lens was derived from the actual tube current-time product value applied to the lens. Image quality was assessed by two independent readers blinded to the type of image reconstruction technique. The average effective scan dose was 1.47±0.26 mSv (FBP) and 0.98±0.15 mSv (IRIS), respectively (33.3% decrease). The average organ dose to the eye lens decreased from 40.0±3.3 mGy (FBP) to 26.6±2.0 mGy (IRIS, 33.5% decrease). No significant change in diagnostic image quality was noted between IRIS and FBP scans (P=0.17). Iterative reconstruction of cerebral MDCT examinations enables reduction of both effective and organ eye lens dose by one third without signficant loss of image quality.

  17. Molecular signatures that correlate with induction of lens regeneration in newts: lessons from proteomic analysis.

    PubMed

    Sousounis, Konstantinos; Bhavsar, Rital; Looso, Mario; Krüger, Marcus; Beebe, Jessica; Braun, Thomas; Tsonis, Panagiotis A

    2014-12-11

    Amphibians have the remarkable ability to regenerate missing body parts. After complete removal of the eye lens, the dorsal but not the ventral iris will transdifferentiate to regenerate an exact replica of the lost lens. We used reverse-phase nano-liquid chromatography followed by mass spectrometry to detect protein concentrations in dorsal and ventral iris 0, 4, and 8 days post-lentectomy. We performed gene expression comparisons between regeneration and intact timepoints as well as between dorsal and ventral iris. Our analysis revealed gene expression patterns associated with the ability of the dorsal iris for transdifferentiation and lens regeneration. Proteins regulating gene expression and various metabolic processes were enriched in regeneration timepoints. Proteins involved in extracellular matrix, gene expression, and DNA-associated functions like DNA repair formed a regeneration-related protein network and were all up-regulated in the dorsal iris. In addition, we investigated protein concentrations in cultured dorsal (transdifferentiation-competent) and ventral (transdifferentiation-incompetent) iris pigmented epithelial (IPE) cells. Our comparative analysis revealed that the ability of dorsal IPE cells to keep memory of their tissue of origin and transdifferentiation is associated with the expression of proteins that specify the dorso-ventral axis of the eye as well as with proteins found highly expressed in regeneration timepoints, especially 8 days post-lentectomy. The study deepens our understanding in the mechanism of regeneration by providing protein networks and pathways that participate in the process.

  18. Performance of 3-Component Nodes in the IRIS Community Wavefield Demonstration Experiment

    NASA Astrophysics Data System (ADS)

    Sweet, J. R.; Anderson, K. R.; Woodward, R.

    2017-12-01

    In June 2016, a field crew of 50 students, faculty, industry personnel, and IRIS staff deployed a total of 390 stations as part of a community seismic experiment above an active seismic lineament in north-central Oklahoma. The goals of the experiment were to test new instrumentation and deployment strategies that record the full seismic wavefield, and to advance understanding of earthquake source processes and regional lithospheric structure. The crew deployed 363 3-component, 5Hz Generation 2 Fairfield Z-Land nodes along three seismic lines and in a seven-layer nested gradiometer array. The seismic lines spanned a region 13 km long by 5 km wide. A broadband, 18 station "Golay 3x6" array with an aperture of approximately 5 km was deployed around the gradiometer and seismic lines to collect waveform data from local and regional events. In addition, 9 infrasound stations were deployed in order to capture and identify acoustic events that might be recorded by the seismic array. The variety and geometry of instrumentation deployed was intended to capture the full seismic wavefield generated by the local and regional seismicity beneath the array and the surrounding region. Additional details on the instrumentation and how it was deployed can be found by visiting our website www.iris.edu/wavefields. We present a detailed analysis of noise across the array—including station performance, as well as noise from nearby sources (wind turbines, automobiles, etc.). We report a clear reduction in noise for buried 3-component nodes compared to co-located surface nodes (see Figure). Using the IRIS DMC's ISPAQ client, we present a variety of metrics to evaluate the network's performance. We also present highlights from student projects at the recently-held IRIS advanced data processing short course, which focused on analyzing the wavefield dataset using array processing techniques.

  19. Iris Crypts Influence Dynamic Changes of Iris Volume.

    PubMed

    Chua, Jacqueline; Thakku, Sri Gowtham; Tun, Tin A; Nongpiur, Monisha E; Tan, Marcus Chiang Lee; Girard, Michael J A; Wong, Tien Yin; Quah, Joanne Hui Min; Aung, Tin; Cheng, Ching-Yu

    2016-10-01

    To determine the association of iris surface features with iris volume change after physiologic pupil dilation in adults. Cross-sectional observational study. Chinese adults aged ≥ 50 years without ocular diseases. Digital iris photographs were taken from eyes of each participant and graded for crypts (by number and size) and furrows (by number and circumferential extent) following a standardized grading scheme. Iris color was measured objectively, using the Commission Internationale de l'Eclairage (CIE) L* color parameter (higher value denoting lighter iris). The anterior segment was imaged by swept-source optical coherence tomography (SS-OCT) (Casia; Tomey, Nagoya, Japan) under bright light and dark room conditions. Iris volumes in light and dark conditions were measured with custom semiautomated software, and the change in iris volume was quantified. Associations of the change in iris volume after pupil dilation with underlying iris surface features in right eyes were assessed using linear regression analysis. Iris volume change after physiologic pupil dilation from light to dark condition. A total of 65 Chinese participants (mean age, 59.8±5.7 years) had gradable data for iris surface features. In light condition, higher iris crypt grade was associated independently with smaller iris volume (β [change in iris volume in millimeters per crypt grade increment] = -1.43, 95% confidence interval [CI], -2.26 to -0.59; P = 0.001) and greater reduction of iris volume on pupil dilation (β [change in iris volume in millimeters per crypt grade increment] = 0.23, 95% CI, 0.06-0.40; P = 0.010), adjusting for age, gender, presence of corneal arcus, and change in pupil size. Iris furrows and iris color were not associated with iris volume in light condition or change in iris volume (all P > 0.05). Although few Chinese persons have multiple crypts on their irides, irides with more crypts were significantly thinner and lost more volume on pupil dilation. In view that the latter feature is known to be protective for acute angle-closure attack, it is likely that the macroscopic and microscopic composition of the iris is a contributing feature to angle-closure disease. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Results in Combined Cataract Surgery With Prosthetic Iris Implantation in Patients With Previous Iridocyclectomy for Iris Melanoma.

    PubMed

    Snyder, Michael E; Osher, Robert H; Wladecki, Trisha M; Perez, Mauricio A; Augsburger, James J; Corrêa, Zélia

    2017-03-01

    To present visual and functional results following implantation of iris prosthesis combined with cataract surgery in eyes with previous iridocyclectomy for iris melanoma or presumed iris melanoma. Retrospective noncomparative case series. Sixteen patients (16 eyes) with iris defects after iridocyclectomy for iris melanoma in 15 cases and iris adenoma in 1 case underwent prosthetic iris device implantation surgery. Prosthetic iris implantation was combined with phacoemulsification and intraocular lens (IOL) implantation. The visual acuity, subjective glare and photophobia reduction, anatomic outcome, and complications were reviewed. Best-corrected visual acuity was improved in 13 eyes (81.25%), remained stable in 2 eyes (12.25%), and decreased in 1 eye (6.25%). Photophobia and glare improved in every case except for 1 (93.75%). Notably, after surgery 12 patients (75.00%) reported no photophobia and 10 patients (62.50%) reported no glare. The median postoperative follow-up was 29.5 months, with a minimum of 5 months and a maximum of 189 months. All iris devices were in the correct position, and all eyes achieved the desired anatomic result. The IOL optic edges were covered in all areas by either residual iris or opaque portions of a prosthetic iris device. In patients who have undergone previous iridocyclectomy for presumed iris melanoma, combined cataract surgery and iris prosthesis placement, with or without iris reconstruction, can lead to visual improvement as well as reduction of both glare and photophobia. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Inadvertent trypan blue posterior capsule staining during cataract surgery.

    PubMed

    Burkholder, Bryn M; Srikumaran, Divya; Nanji, Afshan; Lee, Bryan; Weinberg, Robert S

    2013-04-01

    To report 5 cases of inadvertent posterior capsule staining with trypan blue during phacoemulsification. Retrospective, observational case series. Five cases of posterior capsule staining with trypan blue were identified from cataract surgeries performed at an academic institution. All 5 eyes underwent phacoemulsification with use of iris retractors. The surgical videos from each case were reviewed to better understand the mechanisms and risk factors for posterior capsule staining with trypan blue and techniques to avoid this complication. No eyes had clinical evidence of zonular pathology during their preoperative examination. Only 1 patient reported a possible childhood history of trauma to both eyes. One eye had uveitis, requiring posterior synechialysis. All 5 cases involved the use of iris retractors. No other intraoperative complications occurred, and the intraocular lens was successfully placed in the capsular bag in all cases. All eyes had resolution of posterior capsule staining by postoperative day 8. Inadvertent posterior capsule staining with trypan blue can occur in eyes that appear structurally normal. The use of iris retractors may facilitate posterior capsule staining by allowing the posterior flow of trypan blue under the iris and through the zonules to the posterior capsule. Surgeons should consider techniques to minimize the risk of posterior capsule staining, particularly in cases involving the use of iris retractors. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Systems level feasibility study for the detection of extra-solar planets. Volume 1: Infrared interferometer (IRIS) known as the Stanford Concept

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A sensor system for the direct detection of extrasolar planets from an Earth orbit is evaluated: a spinning, infrared interferometer (IRIS). It is shuttle deployed, free flying, requires no on-orbit assembly and no reservicing over a design life of five years. The sensor concept and the mission objectives are reviewed, and the performance characteristics of a baseline sensor for standard observation conditions are derived. A baseline sensor design is given and the enabling technology discussed. Cost and weight estimates are performed; and a schedule for an IRIS program including technology development and assessment of risk are given. Finally, the sensor is compared with the apodized visual telescope sensor (APOTS) proposed for the same mission. The major conclusions are: that with moderate to strong technology advances, particularly in the fields of long life cryogenics, dynamical control, mirror manufacturing, and optical alignment, the detection of a Jupiter like planet around a Sunlike star at a distance of 30 light years is feasible, with a 3 meter aperture and an observation time of 1 hour. By contrast, major and possibly unlikely breakthroughs in mirror technology are required for APOTS to match this performance.

  3. Tongue prints: A novel biometric and potential forensic tool.

    PubMed

    Radhika, T; Jeddy, Nadeem; Nithya, S

    2016-01-01

    Tongue is a vital internal organ well encased within the oral cavity and protected from the environment. It has unique features which differ from individual to individual and even between identical twins. The color, shape, and surface features are characteristic of every individual, and this serves as a tool for identification. Many modes of biometric systems have come into existence such as fingerprint, iris scan, skin color, signature verification, voice recognition, and face recognition. The search for a new personal identification method secure has led to the use of the lingual impression or the tongue print as a method of biometric authentication. Tongue characteristics exhibit sexual dimorphism thus aiding in the identification of the person. Emerging as a novel biometric tool, tongue prints also hold the promise of a potential forensic tool. This review highlights the uniqueness of tongue prints and its superiority over other biometric identification systems. The various methods of tongue print collection and the classification of tongue features are also elucidated.

  4. Retropupillary fixation of iris-claw lens in visual rehabilitation of aphakic eyes.

    PubMed

    Jayamadhury, G; Potti, Sudhakar; Kumar, K Vinaya; Kumar, R Madhu; Divyansh Mishra, K C; Nambula, Srinivasa Rao

    2016-10-01

    Surgical outcome of retropupillary fixation of iris claw lens. To evaluate the various indications, intra and post-operative complications, and visual outcome of retropupillary fixation of iris claw lens in aphakic eyes. The study design is a retrospective study at a tertiary eye care center. Review of medical records of 61 aphakic eyes of 61 patients, who were rehabilitated with retropupillary fixation of an iris claw lens, with a follow-up duration of at least 1 year. Data analysis was performed using paired t-test and Chi-square test. Mean preoperative uncorrected visual acuity was 1.66 ± 0.3 LogMAR and postoperative acuity at 1 year was 0.53 ± 0.5 LogMAR (P = 0.00001). Preoperative distant best-corrected visual acuity was 0.30 ± 0.48 LogMAR and postoperative acuity at 1 year was 0.27 ± 0.46 LogMAR (P = 0.07). Mean preoperative astigmatism was 1.43 ± 1.94 D and postoperatively was 1.85 ± 2.16 D (P = 0.0127). Mean endothelial cell count was 2353.52 ± 614 cells/mm2 preoperatively which decreased to 2200 ± 728 cells/mm2 at 1 year follow-up (P = 0.006). There was no significant difference in central macular thickness and intraocular pressure pre and post-surgery. Complications included ovalization of pupil in 9.83%, hypotony in 1.63%, toxic anterior segment syndrome in 1.63%, cystoid macular edema in 11.47%, epiretinal membrane in 3.27%, and iris atrophy in 6.55%. Iris claw is a safe and an effective method of rehabilitating aphakic eyes.

  5. Accuracy of student performance while reading leveled books rated at their instructional level by a reading inventory.

    PubMed

    Burns, Matthew K; Pulles, Sandra M; Maki, Kathrin E; Kanive, Rebecca; Hodgson, Jennifer; Helman, Lori A; McComas, Jennifer J; Preast, June L

    2015-12-01

    Identifying a student's instructional level is necessary to ensure that students are appropriately challenged in reading. Informal reading inventories (IRIs) purport to assess the highest reading level at which a student can accurately decode and comprehend text. However, the use of IRIs in determining a student's instructional level has been questioned because of a lack of research. The current study examined the percentage of words read correctly with 64 second- and third-grade students while reading from texts at their instructional level as determined by an IRI. Students read for 1 min from three leveled texts that corresponded to their instructional level as measured by an IRI, and the percentage of words read correctly was recorded. The percentage read correctly correlated across the three books from r=.47 to r=.68 and instructional level categories correlated from tau=.59 to tau=.65. Percent agreement calculations showed that the categorical scores (frustration, instructional, and independent) for the three readings agreed approximately 67% to 70% of the time, which resulted in a kappa estimate of less than .50. Kappa coefficients of .70 are considered strong indicators of agreement. Moreover, more than half of the students with the lowest reading skills read at a frustration level when attempting to read books rated at their instructional level by an IRI. The current study questions how reliably and accurately IRIs identify students' instructional level for reading. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  6. The Immune Pathogenesis of Immune Reconstitution Inflammatory Syndrome Associated with Highly Active Antiretroviral Therapy in AIDS

    PubMed Central

    Zhou, Huaying; He, Yan; Chen, Zi; He, Bo; He, Mei

    2014-01-01

    Abstract The present study investigated the immunological pathogenesis of immune reconstitution inflammatory syndrome (IRIS) in acquired immunodeficiency syndrome (AIDS) patients undergoing highly active antiretroviral therapy (HAART). A total of 238 patients with AIDS who received initial HAART were included in this prospective cohort study. Blood samples were collected immediately, at baseline, at week 12, and at week 24 after initial HAART and at the onset of IRIS. Lymphocyte subsets, Th1 and Th2 cytokines, and interleukin (IL)-7 levels were measured by flow cytometry or ELISA. Among the 238 patients with AIDS who received HAART, 47 patients developed IRIS. The percentages of CD4+ and CD8+ naive, memory, and activated cells exhibited no significant differences between AIDS patients with and without IRIS 24 weeks after initial HAART. The percentage of CD4+CD25+Foxp3+ regulatory T cells was lower in IRIS patients than in non-IRIS patients before HAART, 12 weeks after HAART, 24 weeks after HAART, and at the onset of IRIS. IL-2 and interferon (IFN)-γ levels were significantly higher at week 4 and at the onset of IRIS in IRIS patients than in non-IRIS patients. In contrast, IL-4 and IL-10 levels were significantly lower at week 4 and at the onset of IRIS in IRIS patients than in non-IRIS patients. Plasma IL-7 decreased gradually with the progression of HAART. The level of IL-7 was higher in IRIS patients than in non-IRIS patients at all follow-up time points. An imbalance of Th1/Th2 cytokines, a consistently low CD+CD25+Fox3+ percentage, and a high IL-7 level may be crucial in the pathogenesis of IRIS in AIDS patients who had received HAART. PMID:25131160

  7. Estimating psycho-physiological state of a human by speech analysis

    NASA Astrophysics Data System (ADS)

    Ronzhin, A. L.

    2005-05-01

    Adverse effects of intoxication, fatigue and boredom could degrade performance of highly trained operators of complex technical systems with potentially catastrophic consequences. Existing physiological fitness for duty tests are time consuming, costly, invasive, and highly unpopular. Known non-physiological tests constitute a secondary task and interfere with the busy workload of the tested operator. Various attempts to assess the current status of the operator by processing of "normal operational data" often lead to excessive amount of computations, poorly justified metrics, and ambiguity of results. At the same time, speech analysis presents a natural, non-invasive approach based upon well-established efficient data processing. In addition, it supports both behavioral and physiological biometric. This paper presents an approach facilitating robust speech analysis/understanding process in spite of natural speech variability and background noise. Automatic speech recognition is suggested as a technique for the detection of changes in the psycho-physiological state of a human that typically manifest themselves by changes of characteristics of voice tract and semantic-syntactic connectivity of conversation. Preliminary tests have confirmed that the statistically significant correlation between the error rate of automatic speech recognition and the extent of alcohol intoxication does exist. In addition, the obtained data allowed exploring some interesting correlations and establishing some quantitative models. It is proposed to utilize this approach as a part of fitness for duty test and compare its efficiency with analyses of iris, face geometry, thermography and other popular non-invasive biometric techniques.

  8. PLATEAU IRIS SYNDROME--CASE SERIES.

    PubMed

    Feraru, Crenguta Ioana; Pantalon, Anca Delia; Chiselita, Dorin; Branisteanu, Daniel

    2015-01-01

    Plateau iris is characterized by closing the anterior chamber angle due to a large ciliary body or due to its anterior insertion that alters the position of iris periphery in respect to the trabecular meshwork. There are two aspects that need to be differentiated: plateau iris configuration and plateau iris syndrome. The first describes a situation when the iris root is flat and the anterior chamber is not shallow, the latter refers to a post laser iridotomy condition in which a patent iridotomy has removed the relative pupillary block, but goniscopically confirmed angle closure recurs without central shallowing of the anterior chamber. Isolated plateau iris syndrome is rare compared to plateau iris configuration. We hereby present two case reports of plateau iris syndrome in young patients who came to an ophthalmologic consult by chance.

  9. Iris texture traits show associations with iris color and genomic ancestry.

    PubMed

    Quillen, Ellen E; Guiltinan, Jenna S; Beleza, Sandra; Rocha, Jorge; Pereira, Rinaldo W; Shriver, Mark D

    2011-01-01

    This study seeks to identify associations among genomic biogeographic ancestry (BGA), quantitative iris color, and iris texture traits contributing to population-level variation in these phenotypes. DNA and iris photographs were collected from 300 individuals across three variably admixed populations (Portugal, Brazil, and Cape Verde). Two raters scored the photos for pigmentation spots, Fuchs' crypts, contraction furrows, and Wolflinn nodes. Iris color was quantified from RGB values. Maximum likelihood estimates of individual BGA were calculated from 176 ancestry informative markers. Pigmentation spots, Fuchs' crypts, contraction furrows, and iris color show significant positive correlation with increasing European BGA. Only contraction furrows are correlated with iris color. The relationship between BGA and iris texture illustrates a genetic contribution to this population-level variation. Copyright © 2011 Wiley-Liss, Inc.

  10. Biometric analysis of pigment dispersion syndrome using anterior segment optical coherence tomography.

    PubMed

    Aptel, Florent; Beccat, Sylvain; Fortoul, Vincent; Denis, Philippe

    2011-08-01

    To compare anterior chamber volume (ACV), iris volume, and iridolenticular contact (ILC) area before and after laser peripheral iridotomy (LPI) in eyes with pigment dispersion syndrome (PDS) using anterior segment optical coherence tomography (AS OCT) and image processing software. Cross-sectional study. Eighteen eyes of 18 patients with PDS; 30 eyes of 30 controls matched for age, gender, and refraction. Anterior segment OCT imaging was performed in all eyes before LPI and 1, 4, and 12 weeks after LPI. At each visit, 12 cross-sectional images of the AS were taken: 4 in bright conditions with accommodation (accommodation), 4 in bright conditions without accommodation (physiological miosis), and 4 under dark conditions (physiologic mydriasis). Biometric parameters were estimated using AS OCT radial sections and customized image-processing software. Anterior chamber volume, iris volume-to-length ratio, ILC area, AS OCT anterior chamber depth, and A-scan ultrasonography axial length. Before LPI, PDS eyes had a significantly greater ACV and ILC area than control eyes (P<0.01) and a significantly smaller iris volume-to-length ratio than the controls (P<0.05). After LPI, ACV and ILC area decreased significantly in PDS eyes, but iris volume-to-length ratio increased significantly (P<0.02) and was not significantly different from that of controls. These biometric changes were stable over time. Iris volume-to-length ratio decreased significantly from accommodation to mydriasis and from miosis to mydriasis, both in PDS and control eyes (P<0.01). In PDS eyes, ILC area decreased significantly from accommodation to mydriasis, both before and after LPI (P<0.01). On multivariate analysis, greater anterior chamber (AC) volume (P<0.02) and larger AC depth (P<0.05) before LPI were significant predictors of a larger ILC area. Pigment dispersion syndrome eyes do not have an iris that is abnormally large, relative to the AS size, but have a weakly resistant iris that is stretched and pushed against the lens when there is a pressure difference across the iris. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. [Eyeball perforation of a 7-year-old girl caused by the "Must-Have Office Toy 2017" : The potential risk of injury by a spinning toy (fidget spinner)].

    PubMed

    Nessmann, A; Chaloupka, K; Böni, C

    2018-03-01

    A 7-year-old girl presented to the emergency department of the eye clinic with an eyeball perforation with iris prolapse and corneal as well as scleral wounds of the left eye caused by a spinning toy (fidget spinner). A surgical wound inspection with iris reposition and corneal and scleral suture were performed without delay. This case report demonstrates the potential risk of this popular toy.

  12. The best bits in an iris code.

    PubMed

    Hollingsworth, Karen P; Bowyer, Kevin W; Flynn, Patrick J

    2009-06-01

    Iris biometric systems apply filters to iris images to extract information about iris texture. Daugman's approach maps the filter output to a binary iris code. The fractional Hamming distance between two iris codes is computed and decisions about the identity of a person are based on the computed distance. The fractional Hamming distance weights all bits in an iris code equally. However, not all the bits in an iris code are equally useful. Our research is the first to present experiments documenting that some bits are more consistent than others. Different regions of the iris are compared to evaluate their relative consistency, and contrary to some previous research, we find that the middle bands of the iris are more consistent than the inner bands. The inconsistent-bit phenomenon is evident across genders and different filter types. Possible causes of inconsistencies, such as segmentation, alignment issues, and different filters are investigated. The inconsistencies are largely due to the coarse quantization of the phase response. Masking iris code bits corresponding to complex filter responses near the axes of the complex plane improves the separation between the match and nonmatch Hamming distance distributions.

  13. Immune reconstitution inflammatory syndrome associated with toxoplasmic encephalitis in HIV-infected patients.

    PubMed

    van Bilsen, Ward P H; van den Berg, Charlotte H S B; Rijnders, Bart J A; Brinkman, Kees; Mulder, Jan W; Gelinck, Luc B S; Hoepelman, Andy I M; Wit, Ferdinand W N M; van de Beek, Diederik; Prins, Jan M

    2017-06-19

    To investigate the incidence and risk factors of immune reconstitution inflammatory syndrome (IRIS) associated with toxoplasmic encephalitis (TE) in patients starting combination antiretroviral therapy (cART). A historical multicenter cohort study. We included all HIV-infected patients diagnosed with toxoplasmic encephalitis in six Dutch hospitals between 1996 and 2016. Diagnosis of TE-IRIS was made using predefined IRIS criteria. We distinguished paradoxical TE-IRIS (worsening of underlying treated infection) from unmasking TE-IRIS (unmasking of subclinical infection after start of cART). We compared CD4 cell count, plasma viral load and timing of cART initiation between patients with and without paradoxical TE-IRIS. A total of 211 toxoplasmic encephalitis cases were included. Among 143 cases at risk for paradoxical TE-IRIS, we identified five cases of paradoxical TE-IRIS (3.5%). In six other cases, we could not differentiate paradoxical TE-IRIS from recurrence of disease due to inadequate secondary Toxoplasma prophylaxis. There was no difference in time between start of toxoplasmic encephalitis treatment and cART initiation for patients who did or did not develop paradoxical TE-IRIS (P = 0.50). Within the group of 2228 patients who started cART while having a CD4 cell count below 200 × 10 cells/l and receiving adequate primary prophylaxis, we identified eight cases of unmasking TE-IRIS (0.36%). Unmasking TE-IRIS could not be differentiated from a newly occurring toxoplasmic encephalitis in six other patients, as they were not receiving adequate primary prophylaxis against Toxoplasma. Unmasking TE-IRIS was rare in this cohort, whereas paradoxical TE-IRIS did occur more often. We found no relationship between the timing of cART initiation and the occurrence of paradoxical TE-IRIS.

  14. The International Reference Ionosphere - Climatological Standard for the Ionosphere

    NASA Technical Reports Server (NTRS)

    Bilitza, Dieter

    2006-01-01

    The International Reference Ionosphere (IRI) a joint project of URSI and COSPAR is the defacto standard for a climatological specification of ionospheric parameters. IRI is based on a wide range of ground and space data and has been steadily improved since its inception in 1969 with the ever-increasing volume of ionospheric data and with better mathematical descriptions of the observed global and temporal variation patterns. The IRI model has been validated with a large amount of data including data from the most recent ionospheric satellites (KOMPSAT, ROCSAT and TIMED) and data from global network of ionosondes. Several IRI teams are working on specific aspects of the IRI modeling effort including an improved representation of the topside ionosphere with a seamless transition to the plasmasphere, a new effort to represent the global variation of F2 peak parameters using the Neural Network (NN) technique, and the inclusion of several additional parameters in IRI, e.g., spread-F probability and ionospheric variability. Annual IRI workshops are the forum for discussions of these efforts and for all science activities related to IRI as well as applications of the IRI model in engineering and education. In this paper I will present a status report about the IRI effort with special emphasis on the presentations and results from the most recent IRI Workshops (Paris, 2004; Tortosa, 2005) and on the most important ongoing IRI activities. I will discuss the latest version of the IRI model, IRI-2006, highlighting the most recent changes and additions. Finally, the talk will review some of the applications of the IRI model with special emphasis on the use for radiowave propagation studies and communication purposes.

  15. Association of iris surface features with iris parameters assessed by swept-source optical coherence tomography in Asian eyes.

    PubMed

    Tun, Tin A; Chua, Jacqueline; Shi, Yuan; Sidhartha, Elizabeth; Thakku, Sri Gowtham; Shei, William; Tan, Marcus Chiang Lee; Quah, Joanne Hui Min; Aung, Tin; Cheng, Ching-Yu

    2016-12-01

    To characterise the association of iris surface features (crypts, furrows and colour) with iris volume and curvature assessed by swept-source optical coherence tomography (SSOCT) in Asian eyes. Iris crypts (by number and size) and furrows (by number and circumferential extent) were graded from iris photographs. Iris colour was measured by a customised algorithm written on MATLAB (MathWorks, Natick, Massachusetts, USA). The iris was imaged by SSOCT (SS-1000, CASIA, Tomey, Nagoya, Japan). The associations of surface features with iris parameters were analysed using a generalised estimating equation. A total of 1704 subjects (3297 eyes) were included in the analysis. The majority was Chinese (86.4%), and 63.2% were females, and their mean age (±SD) was 61.4±6.6 years. After adjusting for age, sex, ethnicity, pupil size and corneal arcus, higher iris crypt grade was independently associated with smaller iris volume (β=-0.54, p<0.001), whereas darker irides and higher iris furrow grade were associated with larger iris volume (β=-0.041, p<0.001) and (β=0.233, p<0.001), respectively. Lighter coloured irides with more crypts and/or more furrows were also associated with less convexity (crypts: β=-0.003, p=0.03; furrows: β=-0.004, p=0.007; and colour: β=-0.001, p=0.005). Iris surface features were highly correlated with iris volume and curvature. Irides with more crypts have a smaller volume; and darker irides with more furrows have a larger volume. Lighter irides with more crypts and/or furrows have less convexity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Vagus nerve stimulation mediates protection from kidney ischemia-reperfusion injury through α7nAChR+ splenocytes.

    PubMed

    Inoue, Tsuyoshi; Abe, Chikara; Sung, Sun-Sang J; Moscalu, Stefan; Jankowski, Jakub; Huang, Liping; Ye, Hong; Rosin, Diane L; Guyenet, Patrice G; Okusa, Mark D

    2016-05-02

    The nervous and immune systems interact in complex ways to maintain homeostasis and respond to stress or injury, and rapid nerve conduction can provide instantaneous input for modulating inflammation. The inflammatory reflex referred to as the cholinergic antiinflammatory pathway regulates innate and adaptive immunity, and modulation of this reflex by vagus nerve stimulation (VNS) is effective in various inflammatory disease models, such as rheumatoid arthritis and inflammatory bowel disease. Effectiveness of VNS in these models necessitates the integration of neural signals and α7 nicotinic acetylcholine receptors (α7nAChRs) on splenic macrophages. Here, we sought to determine whether electrical stimulation of the vagus nerve attenuates kidney ischemia-reperfusion injury (IRI), which promotes the release of proinflammatory molecules. Stimulation of vagal afferents or efferents in mice 24 hours before IRI markedly attenuated acute kidney injury (AKI) and decreased plasma TNF. Furthermore, this protection was abolished in animals in which splenectomy was performed 7 days before VNS and IRI. In mice lacking α7nAChR, prior VNS did not prevent IRI. Conversely, adoptive transfer of VNS-conditioned α7nAChR splenocytes conferred protection to recipient mice subjected to IRI. Together, these results demonstrate that VNS-mediated attenuation of AKI and systemic inflammation depends on α7nAChR-positive splenocytes.

  17. Estradiol worsens the syndrome of ischemia-reperfusion injury in an experimental lung transplantation model.

    PubMed

    Santana-Rodríguez, Norberto; Clavo, Bernardino; Llontop, Pedro; López, Ana; García-Castellano, José Manuel; Machín, Rubén P; Ponce, Miguel A; Fiuza, María D; García-Herrera, Ricardo; Brito, Yanira; Yordi, Nagib Atallah; Chirino, Ricardo

    2011-06-01

    Ischemia-reperfusion injury (IRI) is a common complication after lung transplantation. There is evidence that reactive oxygen species are involved in its pathogenesis. We designed an experimental study to evaluate whether the administration of antioxidants to lung transplantation recipients protects against IRI and early acute rejection (AR). Twenty-five rats received left lung transplants after 6 h of ischemia. Fifty minutes before the reperfusion, groups of five rats received a single dose of desferrioxamine (20 mg/kg), estradiol (25 mg/kg), or melatonin (10 mg/kg). The animals were killed 48 h after surgery and the postoperative outcome, IRI, and AR were evaluated. The frequency of severe injury and of moderate-to-severe edema was higher in animals treated with estradiol than in the control group (P = 0.022 and P = 0.026, respectively). No significant changes in the degree of IRI or AR were observed in the groups treated with desferrioxamine or melatonin. In our study, treatment with the antioxidants melatonin or desferrioxamine before reperfusion had no effects on IRI damage or on AR frequency or severity. However, treatment with estradiol resulted in a worse postoperative outcome and in severe edema. Therefore, despite the antioxidant capacity of estradiol, it is recommended that an evaluation of these adverse effects of estradiol in human lung transplant recipients be performed.

  18. Physician acceptance of the IRIS user interface during a clinical trial at the Ottawa Civic Hospital

    NASA Astrophysics Data System (ADS)

    Coristine, Marjorie; Beeton, Carolyn; Tombaugh, Jo W.; Ahuja, J.; Belanger, Garry; Dillon, Richard F.; Currie, Shawn; Hind, E.

    1990-07-01

    During a clinical trial, emergency physicians and radiologists at the Ottawa Civic Hospital used IRIS (Integrated Radiological Information System) to process patients' x-rays, requisitions, and reports, and to have consultations, for 319 active cases. This paper discusses IRIS user interface issues raised during the clinical trial. The IRIS workstation consists of three major system components: 1) an image screen for viewing and enhancing images; 2) a control screen for presenting patient information, selecting images, and executing commands; and 3) a hands-free telephone for reporting activities and consultations. The control screen and hands-free telephone user interface allow physicians to navigate through patient files, select images and access reports, enter new reports, and perform remote consultations. Physicians were observed using the system during the trial and responded to questions about the user interface on an extensive debriefing interview after the trial. Overall, radiologists and emergency physicians were satisfied with IRIS control screen functionality and user interface. In a number of areas radiologists and emergency physicians differed in their user interface needs. Some features were found to be acceptable to one group of physicians but required modification to meet the needs of the other physician group. The data from the interviews, along with the comments from radiologists and emergency physicians provided important information for the revision of some features, and for the evolution of new features.

  19. Multi-wavelength Spectral Analysis of Ellerman Bombs Observed by FISS and IRIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Jie; Ding, M. D.; Cao, Wenda, E-mail: dmd@nju.edu.cn

    Ellerman bombs (EBs) are a kind of solar activity that is suggested to occur in the lower solar atmosphere. Recent observations using the Interface Region Imaging Spectrograph (IRIS) show connections between EBs and IRIS bombs (IBs), which imply that EBs might be heated to a much higher temperature (8 × 10{sup 4} K) than previous results. Here we perform a spectral analysis of EBs simultaneously observed by the Fast Imaging Solar Spectrograph and IRIS. The observational results show clear evidence of heating in the lower atmosphere, indicated by the wing enhancement in H α , Ca ii 8542 Å, andmore » Mg ii triplet lines and also by brightenings in images of the 1700 Å and 2832 Å ultraviolet continuum channels. Additionally, the intensity of the Mg ii triplet line is correlated with that of H α when an EB occurs, suggesting the possibility of using the triplet as an alternative way to identify EBs. However, we do not find any signal in IRIS hotter lines (C ii and Si iv). For further analysis, we employ a two-cloud model to fit the two chromospheric lines (H α and Ca ii 8542 Å) simultaneously, and obtain a temperature enhancement of 2300 K for a strong EB. This temperature is among the highest of previous modeling results, albeit still insufficient to produce IB signatures at ultraviolet wavelengths.« less

  20. Retropupillary iris-claw intraocular lens for the surgical correction of aphakia in cases with microspherophakia.

    PubMed

    Fouda, Sameh Mosaad; Al Aswad, Mahmoud A; Ibrahim, Basem M; Bori, Ashraf; Mattout, Hala K

    2016-12-01

    This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support. This was a prospective, interventional, noncomparative case series. This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively. Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min. Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.

  1. Long-term Outcome of Argon Laser Peripheral Iridoplasty in the Management of Plateau Iris Syndrome Eyes.

    PubMed

    Peterson, Jeffrey R; Anderson, John W; Blieden, Lauren S; Chuang, Alice Z; Feldman, Robert M; Bell, Nicholas P

    2017-09-01

    To report long-term (>5 y) outcomes of plateau iris syndrome patients treated with argon laser peripheral iridoplasty (ALPI). A retrospective chart review was performed on all patients with plateau iris syndrome treated with ALPI from 1996 to 2007. The study included 22 eyes from 22 patients with plateau iris after peripheral iridotomy that were followed for at least 1 year after ALPI. The primary outcome was incidence of needing any intraocular pressure (IOP)-lowering medications or surgery (either a filtering procedure or phacoemulsification). Demographic and baseline clinical data were summarized by mean (±SD) or frequency (percentage). Snellen best-corrected visual acuity was converted to logMAR. The paired t test was used to compare IOP changes, number of IOP-lowering medications, and best-corrected visual acuity from baseline to annual follow-up. Mean follow-up was 76 months. Only 2 (9%) eyes maintained an IOP<21 mm Hg without requiring medication or surgery. Seventeen (77%) eyes underwent surgery at an average of 49.1±7.9 months after ALPI. Eight (36%) eyes underwent filtering surgery, and 9 (41%) eyes underwent phacoemulsification. Three months after cataract extraction, no eyes required IOP-lowering medication. The beneficial effects of ALPI last for <4 years, with the majority of patients (77%) requiring surgery. Phacoemulsification alone was a successful treatment for plateau iris in our patient population.

  2. Ten years of intraoperative floppy iris syndrome in the era of α-blockers

    PubMed Central

    Mohamad Al-Ali, Badereddin; Radmayr, Christian; Weber, Maria; Horninger, Wolfgang; Findl, Oliver; Plas, Eugen

    2017-01-01

    Introduction The use of alpha-1 receptor antagonists in the treatment of benign prostatic hyperplasia (BPH) has created a problem in ophthalmic surgery, the so-called intraoperative floppy iris syndrome (IFIS). This consists of a billowing iris, insufficient pupillary dilation with progressive intraoperative miosis, and protrusion of iris tissue through the tunnel and side port incision that are made for access to the anterior chamber during surgery. IFIS presents particular difficulties in cataract surgery which is carried out through the pupil with manipulations in the immediate vicinity of the iris. The complications range from poor visibility of the operative field to iris damage with the surgical instruments and to rupture of the posterior capsule, with loss of lens material into the vitreous body. Material and methods A comprehensive literature review was performed using MEDLINE with MeSH terms and keywords ‘benign prostatic hyperplasia’, ‘intraoperative floppy iris syndrome’, ‘adrenergic alpha-antagonist’ and ‘cataract surgery’. In addition, reference lists from identified publications were reviewed to identify reports and studies of interest from 2001 to 2017. Results The A total of 95% of experienced ophthalmologic surgeons reported that systematic treatment with tamsulosin represents a challenging surgical condition increasing the risk of complications. Alpha-blockers are commonly prescribed, with 1,079,505 packages of tamsulosin prescribed each month in 2014 in Austria. Dose modification may be one way to reduce the risk of IFIS. A lower incidence of IFIS was reported in patients on tamsulosin in Japan, but the recommended dosage was lower than that used in Europe and the US (0.2 mg vs. 0.4 mg). Conclusions We showed that not all patients taking tamsulosin experience IFIS. Moreover, larger investigations with a prospective design are needed, including studies to monitor the pre- and post-therapeutic ophthalmologic changes under tamsulosin, as well as urodynamic improvements resulting from this therapy. PMID:29732214

  3. ISO Technical Specification for the Ionosphere -IRI Recent Activities

    NASA Astrophysics Data System (ADS)

    Bilitza, Dieter; Reinisch, Bodo; Tamara, Gulyaeva

    ISO Technical Specification TS 16457 recommends the International Reference Ionosphere (IRI) for the specification of ionospheric densities and temperatures. We review the latest develop-ments towards improving the IRI model and the newest version of the model IRI-2010. IRI-2010 includes several important improvements and additions. This presentation introduces these changes and discusses their benefits. The changes affect primarily the density profiles in the bottomside ionosphere and the density and height of the F2 peak, the point of highest density in the ionosphere. An important new addition to the model is the inclusion of auroral boundaries and their movement with magnetic activity. We will also discuss the status of other ongoing IRI activities and some of the recent applications of the IRI model. The homepage for the IRI project is at http://IRI.gsfc.nasa.gov/.

  4. Hand Grasping Synergies As Biometrics.

    PubMed

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  5. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors

    PubMed Central

    Skalet, Alison H.; Li, Yan; Lu, Chen D.; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G.; Thomas, Charles R.; Huang, David

    2016-01-01

    Objective To evaluate tumor vasculature with optical coherence tomography (OCT) angiography (OCTA) in malignant iris melanomas and benign iris lesions. Design Cross-sectional observational clinical study. Participants Patients with iris lesions and healthy volunteers. Methods Eyes were imaged using OCTA systems operating at 1050 and 840 nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanomas patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. Main Outcome Measures OCT and OCTA images, qualitative evaluation of iris and tumor vasculature and quantitative vessel density. Results One eye each of eight normal volunteers and nine patients with iris melanomas or benign iris lesions including freckles, nevi, and an iris pigment epithelial (IPE) cyst were imaged. The normal iris has radially-oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In two eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, p<0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050 nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% participants in whom imaging was attempted. Conclusions This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors including iris melanocytic lesions for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. PMID:27856029

  6. Optical Coherence Tomography Angiography Characteristics of Iris Melanocytic Tumors.

    PubMed

    Skalet, Alison H; Li, Yan; Lu, Chen D; Jia, Yali; Lee, ByungKun; Husvogt, Lennart; Maier, Andreas; Fujimoto, James G; Thomas, Charles R; Huang, David

    2017-02-01

    To evaluate tumor vasculature with optical coherence tomography angiography (OCTA) in malignant iris melanomas and benign iris lesions. Cross-sectional observational clinical study. Patients with iris lesions and healthy volunteers. Eyes were imaged using OCTA systems operating at 1050- and 840-nm wavelengths. Three-dimensional OCTA scans were acquired. Iris melanoma patients treated with radiation therapy were imaged again after I-125 plaque brachytherapy at 6 and 18 months. OCT and OCTA images, qualitative evaluation of iris and tumor vasculature, and quantitative vessel density. One eye each of 8 normal volunteers and 9 patients with iris melanomas or benign iris lesions, including freckles, nevi, and an iris pigment epithelial (IPE) cyst, were imaged. The normal iris has radially oriented vessels within the stroma on OCTA. Penetration of flow signal in normal iris depended on iris color, with best penetration seen in light to moderately pigmented irides. Iris melanomas demonstrated tortuous and disorganized intratumoral vasculature. In 2 eyes with nevi there was no increased vascularity; in another, fine vascular loops were noted near an area of ectropion uveae. Iris freckles and the IPE cyst did not have intrinsic vascularity. The vessel density was significantly higher within iris melanomas (34.5%±9.8%, P < 0.05) than in benign iris nevi (8.0%±1.4%) or normal irides (8.0%±1.2%). Tumor regression after radiation therapy for melanomas was associated with decreased vessel density. OCTA at 1050 nm provided better visualization of tumor vasculature and penetration through thicker tumors than at 840 nm. But in very thick tumors and highly pigmented lesions even 1050-nm OCTA could not visualize their full thickness. Interpretable OCTA images were obtained in 82% of participants in whom imaging was attempted. This is the first demonstration of OCTA in iris tumors. OCTA may provide a dye-free, no-injection, cost-effective method for monitoring a variety of tumors, including iris melanocytic lesions, for growth and vascularity. This could be helpful in evaluating tumors for malignant transformation and response to treatment. Penetration of the OCT beam remains a limitation for highly pigmented tumors, as does the inability to image the entire iris in a single field. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  7. Observation and modelling of the Fe XXI line profile observed by IRIS during the impulsive phase of flares

    NASA Astrophysics Data System (ADS)

    Polito, V.; Testa, P.; De Pontieu, B.; Allred, J. C.

    2017-12-01

    The observation of the high temperature (above 10 MK) Fe XXI 1354.1 A line with the Interface Region Imaging Spectrograph (IRIS) has provided significant insights into the chromospheric evaporation process in flares. In particular, the line is often observed to be completely blueshifted, in contrast to previous observations at lower spatial and spectral resolution, and in agreement with predictions from theoretical models. Interestingly, the line is also observed to be mostly symmetric and with a large excess above the thermal width. One popular interpretation for the excess broadening is given by assuming a superposition of flows from different loop strands. In this work, we perform a statistical analysis of Fe XXI line profiles observed by IRIS during the impulsive phase of flares and compare our results with hydrodynamic simulations of multi-thread flare loops performed with the 1D RADYN code. Our results indicate that the multi-thread models cannot easily reproduce the symmetry of the line and that some other physical process might need to be invoked in order to explain the observed profiles.

  8. A young Botswana patient with congenital iris ectropion uvea.

    PubMed

    Shifa, Jemal Zeberga; Nkomazana, Othokawa; Bekele, Negussie Alula; Kassa, Mamo Woldu

    2016-01-01

    Congenital iris ectropion is a rare condition; non-progressive anomaly characterised by the presence of iris pigment epithelium on the anterior surface of the iris stroma and is frequently associated with anterior iris insertion, dysgenesis of the drainage angle and glaucoma. This paper describes unusual case of bilateral case of congenital iris ectropion in adult patient with pupillary abnormality, normal anterior chamber angle structure and with no evidence of glaucoma.

  9. Monocyte Phenotype and IFN-γ-Inducible Cytokine Responses Are Associated with Cryptococcal Immune Reconstitution Inflammatory Syndrome

    PubMed Central

    Meya, David B.; Okurut, Samuel; Zziwa, Godfrey; Cose, Stephen; Bohjanen, Paul R.; Mayanja-Kizza, Harriet; Joloba, Moses; Boulware, David R.; Yukari Manabe, Carol; Wahl, Sharon; Janoff, Edward N.

    2017-01-01

    A third of adults with AIDS and cryptococcal meningitis (CM) develop immune reconstitution inflammatory syndrome (IRIS) after initiating antiretroviral therapy (ART), which is thought to result from exaggerated inflammatory antigen-specific T cell responses. The contribution of monocytes to the immunopathogenesis of cryptococcal IRIS remains unclear. We compared monocyte subset frequencies and immune responses in HIV-infected Ugandans at time of CM diagnosis (IRIS-Baseline) for those who later developed CM-IRIS, controls who did not develop CM-IRIS (Control-Baseline) at CM-IRIS (IRIS-Event), and for controls at a time point matched for ART duration (Control-Event) to understand the association of monocyte distribution and immune responses with cryptococcal IRIS. At baseline, stimulation with IFN-γ ex vivo induced a higher frequency of TNF-α- and IL-6-producing monocytes among those who later developed IRIS. Among participants who developed IRIS, ex vivo IFN-γ stimulation induced higher frequencies of activated monocytes, IL-6+, TNF-α+ classical, and IL-6+ intermediate monocytes compared with controls. In conclusion, we have demonstrated that monocyte subset phenotype and cytokine responses prior to ART are associated with and may be predictive of CM-IRIS. Larger studies to further delineate innate immunological responses and the efficacy of immunomodulatory therapies during cryptococcal IRIS are warranted. PMID:29371546

  10. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 2-HEXANONE

    EPA Science Inventory

    EPA will conduct an assessment of the noncancer health effects of 2-hexanone. The IRIS program will prepare an IRIS assessment for 2-hexanone. The IRIS assessment for 2-hexanone will consist of a Toxicological Review and an IRIS Summary. The Toxicological Review is a critical ...

  11. Performance of the IRI-2007 Model for Equatorial Topside Ion Density in the African Sector for Low and Extremely Low Solar Activity

    NASA Technical Reports Server (NTRS)

    Klenzing, J.; Simoes, F.; Ivanov, S.; Bilitza, D.; Heelis, R. A.; Rowland, D.

    2012-01-01

    The recent availability of new data sets during the recent extreme solar minimum provides an opportunity for testing the performance of the International Reference Ionosphere in historically under-sampled regions. This study will present averages and variability of topside ionospheric densities over Africa as a function of season, local time, altitude, and magnetic dip latitude as measured by the Coupled Ion-Neutral Dynamics Investigation (CINDI) Mission of Opportunity on the C/NOFS satellite. The results will be compared to the three topside model options available in IRI-2007. Overall, the NeQuick model is found to have the best performance, though during the deepest part of the solar minimum all three options significantly overestimate density.

  12. IRIS COLOUR CLASSIFICATION SCALES – THEN AND NOW

    PubMed Central

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual’s eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale. PMID:27373112

  13. IRIS COLOUR CLASSIFICATION SCALES--THEN AND NOW.

    PubMed

    Grigore, Mariana; Avram, Alina

    2015-01-01

    Eye colour is one of the most obvious phenotypic traits of an individual. Since the first documented classification scale developed in 1843, there have been numerous attempts to classify the iris colour. In the past centuries, iris colour classification scales has had various colour categories and mostly relied on comparison of an individual's eye with painted glass eyes. Once photography techniques were refined, standard iris photographs replaced painted eyes, but this did not solve the problem of painted/ printed colour variability in time. Early clinical scales were easy to use, but lacked objectivity and were not standardised or statistically tested for reproducibility. The era of automated iris colour classification systems came with the technological development. Spectrophotometry, digital analysis of high-resolution iris images, hyper spectral analysis of the human real iris and the dedicated iris colour analysis software, all accomplished an objective, accurate iris colour classification, but are quite expensive and limited in use to research environment. Iris colour classification systems evolved continuously due to their use in a wide range of studies, especially in the fields of anthropology, epidemiology and genetics. Despite the wide range of the existing scales, up until present there has been no generally accepted iris colour classification scale.

  14. Immunopathology of immune reconstitution inflammatory syndrome in Whipple's disease.

    PubMed

    Moos, Verena; Feurle, Gerhard E; Schinnerling, Katina; Geelhaar, Anika; Friebel, Julian; Allers, Kristina; Moter, Annette; Kikhney, Judith; Loddenkemper, Christoph; Kühl, Anja A; Erben, Ulrike; Fenollar, Florence; Raoult, Didier; Schneider, Thomas

    2013-03-01

    During antimicrobial treatment of classic Whipple's disease (CWD), the chronic systemic infection with Tropheryma whipplei, immune reconstitution inflammatory syndrome (IRIS), is a serious complication. The aim of our study was to characterize the immunological processes underlying IRIS in CWD. Following the definition of IRIS, we describe histological features of IRIS and immunological parameters of 24 CWD IRIS patients, 189 CWD patients without IRIS, and 89 healthy individuals. T cell reconstitution, Th1 reactivity, and the phenotype of T cells were described in the peripheral blood, and infiltration of CD4(+) T cells and regulatory T cells in the duodenal mucosa was determined. During IRIS, tissues were heavily infiltrated by CD3(+), predominantly CD45RO(+)CD4(+) T cells. In the periphery, initial reduction of CD4(+) cell counts and their reconstitution on treatment was more pronounced in CWD patients with IRIS than in those without IRIS. The ratio of activated and regulatory CD4(+) T cells, nonspecific Th1 reactivity, and the proportion of naive among CD4(+) T cells was high, whereas serum IL-10 was low during IRIS. T. whipplei-specific Th1 reactivity remained suppressed before and after emergence of IRIS. The findings that IRIS in CWD mainly are mediated by nonspecific activation of CD4(+) T cells and that it is not sufficiently counterbalanced by regulatory T cells indicate that flare-up of pathogen-specific immunoreactivity is not instrumental in the pathogenesis of IRIS in CWD.

  15. Physiologic effects of rhythmical massage: a prospective exploratory cohort study.

    PubMed

    Wälchli, Chantal; Saltzwedel, Georg; Krüerke, Daniel; Kaufmann, Christoph; Schnorr, Bettina; Rist, Lukas; Eberhard, Jutta; Decker, Michael; Simões-Wüst, Ana Paula

    2014-06-01

    This study was performed to characterize the physiologic effects of rhythmical massage (RM), an anthroposophic therapy whose effectiveness is supported by empirical observations and a prospective observational study. Patients referred to RM at the Paracelsus Hospital Richterswil for any indication were continuously enrolled. They received an average of 10 RM sessions, which included not only the massage but also therapeutic rest in the supine position immediately thereafter. Effects of RM on surface temperature and on heart rate variability (HRV) were determined with infrared imaging (IRI) and electrocardiography (ECG), respectively. IRI of the patients' dorsal region was performed without clothes, in standing position, at the start and at the end of two waiting periods before and after RM. ECG was performed from the beginning of the first waiting period until the end of the second one. Results on IRI from 9 and ECG from 11 patients could be analyzed. RM led to an immediate increase in dorsal temperature. Furthermore, comparison of the IRI images for consecutive RM sessions showed a tendency toward improved warmth distribution as a progressive therapy effect. Analysis of the EGC results recorded during the waiting periods-in the sitting position--showed a significant increase of HRV after RM, as detected by the standard deviation of the beat-to-beat periods and a relative increase of low-frequency power. During the course of the RM sessions, the change in HRV during the therapeutic rest period depended on the initial value: Low initial values were enhanced, whereas high ones were reduced. RM led to an immediate increase in the patient's dorsal surface temperature, as well as increased HRV and sympathetic stimulation. In the long term, RM resulted in a progressive improvement of warmth distribution and regulation of the resting HRV.

  16. Modeling the Lower Part of the Topside Ionospheric Vertical Electron Density Profile Over the European Region by Means of Swarm Satellites Data and IRI UP Method

    NASA Astrophysics Data System (ADS)

    Pignalberi, A.; Pezzopane, M.; Rizzi, R.

    2018-03-01

    An empirical method to model the lower part of the ionospheric topside region from the F2 layer peak height to about 500-600 km of altitude over the European region is proposed. The method is based on electron density values recorded from December 2013 to June 2016 by Swarm satellites and on foF2 and hmF2 values provided by IRI UP (International Reference Ionosphere UPdate), which is a method developed to update the IRI model relying on the assimilation of foF2 and M(3000)F2 data routinely recorded by a network of European ionosonde stations. Topside effective scale heights are calculated by fitting some definite analytical functions (α-Chapman, β-Chapman, Epstein, and exponential) through the values recorded by Swarm and the ones output by IRI UP, with the assumption that the effective scale height is constant in the altitude range considered. Calculated effective scale heights are then modeled as a function of foF2 and hmF2, in order to be operationally applicable to both ionosonde measurements and ionospheric models, like IRI. The method produces two-dimensional grids of the median effective scale height binned as a function of foF2 and hmF2, for each of the considered topside profiles. A statistical comparison with Constellation Observing System for Meteorology, Ionosphere, and Climate/FORMOsa SATellite-3 collected Radio Occultation profiles is carried out to assess the validity of the proposed method and to investigate which of the considered topside profiles is the best one. The α-Chapman topside function displays the best performance compared to the others and also when compared to the NeQuick topside option of IRI.

  17. Steatotic livers are susceptible to normothermic ischemia-reperfusion injury from mitochondrial Complex-I dysfunction

    PubMed Central

    Chu, Michael JJ; Premkumar, Rakesh; Hickey, Anthony JR; Jiang, Yannan; Delahunt, Brett; Phillips, Anthony RJ; Bartlett, Adam SJR

    2016-01-01

    AIM: To assess the effects of ischemic preconditioning (IPC, 10-min ischemia/10-min reperfusion) on steatotic liver mitochondrial function after normothermic ischemia-reperfusion injury (IRI). METHODS: Sixty male Sprague-Dawley rats were fed 8-wk with either control chow or high-fat/high-sucrose diet inducing > 60% mixed steatosis. Three groups (n = 10/group) for each dietary state were tested: (1) the IRI group underwent 60 min partial hepatic ischemia and 4 h reperfusion; (2) the IPC group underwent IPC prior to same standard IRI; and (3) sham underwent the same surgery without IRI or IPC. Hepatic mitochondrial function was analyzed by oxygraphs. Mitochondrial Complex-I, Complex-II enzyme activity, serum alanine aminotransferase (ALT), and histological injury were measured. RESULTS: Steatotic-IRI livers had a greater increase in ALT (2476 ± 166 vs 1457 ± 103 IU/L, P < 0.01) and histological injury following IRI compared to the lean liver group. Steatotic-IRI demonstrated lower Complex-I activity at baseline [78.4 ± 2.5 vs 116.4 ± 6.0 nmol/(min.mg protein), P < 0.001] and following IRI [28.0 ± 6.2 vs 104.3 ± 12.6 nmol/(min.mg protein), P < 0.001]. Steatotic-IRI also demonstrated impaired Complex-I function post-IRI compared to the lean liver IRI group. Complex-II activity was unaffected by hepatic steatosis or IRI. Lean liver mitochondrial function was unchanged following IRI. IPC normalized ALT and histological injury in steatotic livers but had no effect on overall steatotic liver mitochondrial function or individual mitochondrial complex enzyme activities. CONCLUSION: Warm IRI impairs steatotic liver Complex-I activity and function. The protective effects of IPC in steatotic livers may not be mediated through mitochondria. PMID:27217699

  18. IRIS Toxicological Review and Summary Documents for N ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of n-hexane was last prepared and added to the IRIS data base in 1990. The IRIS program is updating the IRIS assessment for n-hexane; this update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for n-hexane will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of n-hexane (RfD and RfC) and a cancer assessment, where supported by available data. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for n-hexane. The outcome of this project is an updated Toxicological Review and IRIS Summary for n-Hexane that will be entered into the IRIS database. IRIS is an EPA data base containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment

  19. A Statistical Analysis of IrisCode and Its Security Implications.

    PubMed

    Kong, Adams Wai-Kin

    2015-03-01

    IrisCode has been used to gather iris data for 430 million people. Because of the huge impact of IrisCode, it is vital that it is completely understood. This paper first studies the relationship between bit probabilities and a mean of iris images (The mean of iris images is defined as the average of independent iris images.) and then uses the Chi-square statistic, the correlation coefficient and a resampling algorithm to detect statistical dependence between bits. The results show that the statistical dependence forms a graph with a sparse and structural adjacency matrix. A comparison of this graph with a graph whose edges are defined by the inner product of the Gabor filters that produce IrisCodes shows that partial statistical dependence is induced by the filters and propagates through the graph. Using this statistical information, the security risk associated with two patented template protection schemes that have been deployed in commercial systems for producing application-specific IrisCodes is analyzed. To retain high identification speed, they use the same key to lock all IrisCodes in a database. The belief has been that if the key is not compromised, the IrisCodes are secure. This study shows that even without the key, application-specific IrisCodes can be unlocked and that the key can be obtained through the statistical dependence detected.

  20. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 1,1,1-TRICHLOROETHANE (PEER REVIEW PLAN)

    EPA Science Inventory

    EPA's assessment of the carcinogenic potential of 1,1,1-trichloroethane was entered into the IRIS database in 1988, and the assessment of noncancer effects following oral exposure was withdrawn from IRIS in 1991. The IRIS program prepared an update of the IRIS assessment for 1,1,...

  1. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    EPA Pesticide Factsheets

    In January 2017, EPA finalized the IRIS assessment of Benzo[a]pyrene. The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  2. The International Reference Ionosphere Today and in the Future

    NASA Technical Reports Server (NTRS)

    Bilitza, Dieter; McKinnell, Lee-Ane; Reinisch, Bodo; Fuller-Rowell,Tim

    2010-01-01

    The international reference ionosphere (IRI) is the internationally recognized and recommended standard for the specification of plasma parameters in Earth's ionosphere. It describes monthly averages of electron density, electron temperature, ion temperature, ion composition, and several additional parameters in the altitude range from 60 to 1,500 km. A joint working group of the Committee on Space Research (COSPAR) and the International Union of Radio Science (URSI) is in charge of developing and improving the IRI model. As requested by COSPAR and URSI, IRI is an empirical model being based on most of the available and reliable data sources for the ionospheric plasma. The paper describes the latest version of the model and reviews efforts towards future improvements, including the development of new global models for the F2 peak density and height, and a new approach to describe the electron density in the topside and plasmasphere. Our emphasis will be on the electron density because it is the IRI parameter most relevant to geodetic techniques and studies. Annual IRI meetings are the main venue for the discussion of IRI activities, future improvements, and additions to the model. A new special IRI task force activity is focusing on the development of a real-time IRI (RT-IRI) by combining data assimilation techniques with the IRI model. A first RT-IRI task force meeting was held in 2009 in Colorado Springs. We will review the outcome of this meeting and the plans for the future. The IRI homepage is at http://www.IRI.gsfc.nasa.gov

  3. Lattice-like collagen fiber meshwork in the iris stroma of the cat: a possible mechanism to generate the tension directed towards the iris root which is required for pupillary dilatation in the sympathectomized eye.

    PubMed

    Sakuraba, M; Yun, S; Ichinohe, N; Yonekura, H; Shoumura, K

    1999-10-01

    NaOH digestion technique for collagen fiber dissection and scanning electron microscopy demonstrated a lattice-like meshwork in the anterior surface of the iris stroma of the cat. The mesh threads were made of collagen fibril bundles. In the constricted pupil, the meshes were square to rhomboid with the diagonals in the direction of the radius or circumference of the iris. In the dilated pupil, however, the meshes were strongly flattened rhomboid or ellipse with a longer diagnoal or axis in the circumferential direction. At the mesh corners facing the pupillary margin or the iris root, the collagen fibril bundles were strongly bent in the iris of the constricted pupil, while they were almost straight or slightly wavy in the iris of the dilated pupil. Accumulation of elasticity tension generated by this small distortion of the iris-mesh threads in the constricted pupil was considered to generate a tension directed towards the iris root, which is required for pupillary dilatation in the sympathectomized eye. On the posterior surface of the iris stroma, numerous thin pleats tightly woven with collagen fibrils traversed straightway through the radial length of the ciliary zone of the iris in both constricted and dilated pupils. The structural changes of these pleats in miosis and mydriasis were very small compared with the meshwork of the anterior aspect of the iris. Therefore, they were considered to work mainly as an iris skeleton.

  4. IRIS Toxicological Review of Hexahydro-1,3,5-Trinitro-1,3,5 ...

    EPA Pesticide Factsheets

    EPA is developing an Integrated Risk Information System (IRIS) assessment of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and has released the draft assessment for public comment. When final, the assessment will appear on the IRIS database. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for RDX. The outcome of this project is an updated Toxicological Review and IRIS Summary for RDX that will be entered into the IRIS database.

  5. IRIS Toxicological Review of Benzo[a]pyrene (Public ...

    EPA Pesticide Factsheets

    EPA is developing an Integrated Risk Information System (IRIS) assessment of benzo[a]pyrene and has released the draft assessment for public comment and external peer review. When final, the assessment will appear on the IRIS database. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  6. Comprehensive Evaluation of Stand-Off Biometrics Techniques for Enhanced Surveillance during Major Events

    DTIC Science & Technology

    2011-02-01

    transactions. Analysts used  frame  counts to  measure  the duration for which the Test Subject interacted with the iris recognition system camera, from the...44  Figure 20:  Frame  Extracted from HD CCTV Video...the eyes are located and used as a  frame  of reference. Once the eyes are  located, the face image can be rotated clockwise or counter‐clockwise to

  7. IRIS Toxicological Review of Tert-Butyl Alcohol (Tert-Butanol) ...

    EPA Pesticide Factsheets

    On April 29, 2016, the Toxicological Review of tert-Butyl Alcohol (tert-Butanol) (Public Comment Draft) was released for public comment. The draft Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and the Executive Office of the President during Step 3 (Interagency Science Consultation) before public release. As part of the IRIS process, all written interagency comments on IRIS assessments will be made publicly available. Accordingly, interagency comments with EPA's response and the interagency science consultation drafts of the IRIS Toxicological Review of tert-Butanol and charge to external peer reviewers are posted on this site. EPA is undertaking a new health assessment for t-butyl alcohol (tert-butanol) for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS and IRIS Summary of TBA that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information to evaluate potential public health risks associated with environmental contaminants. The IRIS database is relied on for the development of risk assessments, site-specific environmental decisions, and rule making.

  8. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (Etbe) ...

    EPA Pesticide Factsheets

    In September 2016, EPA released the draft IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) for public comment and discussion. The draft assessment was reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Ethyl Tertiary Butyl Ether are posted on this site. EPA is undertaking an new health assessment for ethyl tertiary butyl ether (ETBE) for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS Summary of ETBE that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used nationally and internationally in combination with specific situational exposure assessment infor

  9. IRIS Toxicological Review of Biphenyl (Interagency Science ...

    EPA Pesticide Factsheets

    On September 30, 2011, the draft Toxicological Review of Biphenyl and the charge to external peer reviewers were released for external peer review and public comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. In the new IRIS process (May 2009), introduced by the EPA Administrator, all written comments on IRIS assessments submitted by other federal agencies and White House Offices will be made publicly available. Accordingly, interagency comments and the interagency science consultation draft of the IRIS Toxicological Review of Biphenyl and the charge to external peer reviewers are posted on this site. EPA is undertaking a new health assessment for biphenyl for the Integrated Risk Information System (IRIS). The outcome of this project will be a Toxicological Review and IRIS and IRIS Summary of biohenyl that will be entered on the IRIS database. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information to evaluate potential public health risks associated with exposure assessment information to evaluate potential public health risks associated with environmental contaminants. The IRIS database is relied on for the development of risk ass

  10. IRIS TOXICOLOGICAL REVIEW AND SUMMARY ...

    EPA Pesticide Factsheets

    EPA's assessment of the noncancer health effects and carcinogenic potential of 1,2,3-trichloropropane (TCP) was added to the IRIS database in 1990. The IRIS program is updating the IRIS assessment for TCP. This update will incorporate health effects information published since the last assessment was prepared as well as new risk assessment methods. The IRIS assessment for TCP will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physicochemical and toxicokinetic properties of the chemical and its toxicity in humans and experimental systems. The assessment will present reference values for noncancer effects of TCP (RfD and RfC) and a cancer assessment. The Toxicological Review and IRIS Summary will be subject to internal peer consultation, Agency review, and external scientific peer review. The final products will constitute the Agency's opinion on the toxicity of TCP. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for 1,2,3-trichloropropane. IRIS is an EPA database containing the Agency's consensus scientific positions on potential adverse human effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment process, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in

  11. Matrix metalloproteinases and tissue damage in HIV-tuberculosis immune reconstitution inflammatory syndrome

    PubMed Central

    Tadokera, Rebecca; Meintjes, Graeme A; Wilkinson, Katalin A; Skolimowska, Keira H; Walker, Naomi; Friedland, Jon S; Maartens, Gary; Elkington, Paul T G; Wilkinson, Robert J

    2014-01-01

    The HIV-TB-associated immune reconstitution inflammatory syndrome (TB-IRIS) can complicate combined treatments for HIV-1 and TB. Little is known about tissue damage in TB-IRIS. Matrix metalloproteinases (MMPs) degrade components of the extracellular matrix and consequently may play a role in such immunopathology. Here we investigated the involvement of MMPs in TB-IRIS. We determined MMP transcript abundance and secreted protein in Mycobacterium tuberculosis stimulated PBMCs from 22 TB-IRIS patients and 22 non-IRIS controls. We also measured MMP protein levels in corresponding serum and the effect of prednisone — which reduces the duration of symptoms in IRIS patients — or placebo treatment on MMP transcript and circulating MMP protein levels. PBMCs from TB-IRIS had increased MMP-1,-3,-7, and-10 transcript levels when compared with those of controls at either 6 or 24 h. Similarly, MMP-1,-3,-7, and-10 protein secretion in stimulated cultures was higher in TB-IRIS than in controls. Serum MMP-7 concentration was elevated in TB-IRIS and 2 weeks of corticosteroid therapy decreased this level, although not significantly. TB-IRIS is associated with a distinct pattern of MMP gene and protein activation. Modulation of dysregulated MMP activity may represent a novel therapeutic approach to alleviate TB-IRIS in HIV-TB patients undergoing treatment. PMID:24136296

  12. [Moxiflaxin and iris transillumination].

    PubMed

    Broens, A; Collignon, N

    2016-07-01

    Bilateral Acute Iris Transillumination (BAIT) is a new clinical entity characterized by acute onset of pigment dispersion in the anterior chamber and angle, depigmentation of the iris stroma and permanent iris transillumination, masquerading as uveitis. An association with oral moxifloxacin is reported in some articles. We describe one case of bilateral acute iris transillumination, following the use of systemic moxifloxacin.

  13. Iris melanocytoma.

    PubMed

    Radovanović, Anica Bobić; Krnjaja, Bojana Dacić; Jaksić, Vesna

    2016-01-01

    Iris melanocytoma (IM) is a rare benign tumor, but unavoidable in differential diagnosis of pigmented iris lesions. According to the best knowledge of the authors it is for the first time in Serbia that a well-documented case of IM is presented and that the problem of this tumor is discussed. In the left eye of a 47-year-old white female at the iris in a six o'clock position, a highly pigmented, dome shaped lesion with a crater-like cavity in the center and with feathery margins was noticed. There were no signs of infiltration of surrounding tissue or intrinsic vessels and the lens was clear. Visual acuity and intraocular pressure were normal. An ultrasound biomicroscopy (UBM) revealed a well-defined lesion with high internal reflectivity, with a base diameter of 1.25 mm and a thickness of 0.80 mm in the periphery, and 0.53 mm in the central part.The diagnosis of IM of the left eye was established and regular checkups were performed for ten years. No changes in clinical or UBM presentation were established. Awareness of clinical presentation of IM is most important for correct diagnosis. Ultrasound biomicroscopy is a useful diagnostic procedure in the following up of IM.

  14. A pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding.

    PubMed

    Yoshida, Yukinaga; Matsuda, Koji; Tamai, Naoto; Yoshizawa, Kai; Nikami, Toshiki; Ishiguro, Haruya; Tajiri, Hisao

    2014-01-01

    Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.

  15. Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera

    PubMed Central

    Chen, Hao; Woodward, Maria A.; Burke, David T.; Jeganathan, V. Swetha E.; Demirci, Hakan; Sick, Volker

    2017-01-01

    A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring. PMID:29082081

  16. Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera.

    PubMed

    Chen, Hao; Woodward, Maria A; Burke, David T; Jeganathan, V Swetha E; Demirci, Hakan; Sick, Volker

    2017-10-01

    A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring.

  17. Validation of a published case definition for tuberculosis-associated immune reconstitution inflammatory syndrome.

    PubMed

    Haddow, Lewis J; Moosa, Mahomed-Yunus S; Easterbrook, Philippa J

    2010-01-02

    To evaluate the International Network for the Study of HIV-associated IRIS (INSHI) case definitions for tuberculosis (TB)-associated immune reconstitution inflammatory syndrome (IRIS) in a South African cohort. Prospective cohort of 498 adult HIV-infected patients initiating antiretroviral therapy. Patients were followed up for 24 weeks and all clinical events were recorded. Events with TB-IRIS as possible cause were assessed by consensus expert opinion and INSHI case definition. Positive, negative, and chance-corrected agreement (kappa) were calculated, and reasons for disagreement were assessed. One hundred and two (20%) patients were receiving TB therapy at antiretroviral therapy initiation. Three hundred and thirty-three events were evaluated (74 potential paradoxical IRIS, 259 potential unmasking IRIS). Based on expert opinion, there were 18 cases of paradoxical IRIS associated with TB and/or other opportunistic disease. The INSHI criteria for TB-IRIS agreed in 13 paradoxical cases, giving positive agreement of 72.2%, negative agreement in 52/56 non-TB-IRIS events (92.9%), and kappa of 0.66. There were 19 unmasking TB-IRIS cases based on expert opinion, of which 12 were considered IRIS using the INSHI definition (positive agreement 63.2%). There was agreement in all 240 non-TB-IRIS events (negative agreement 100%) and kappa was 0.76. There was good agreement between the INSHI case definition for both paradoxical and unmasking TB-IRIS and consensus expert opinion. These results support the use of this definition in clinical and research practice, with minor caveats in its application.

  18. Engineering a Light-Attenuating Artificial Iris

    PubMed Central

    Shareef, Farah J.; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-01-01

    Purpose Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. Methods The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Results Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Conclusions Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage. PMID:27116547

  19. Engineering a Light-Attenuating Artificial Iris.

    PubMed

    Shareef, Farah J; Sun, Shan; Kotecha, Mrignayani; Kassem, Iris; Azar, Dimitri; Cho, Michael

    2016-04-01

    Discomfort from light exposure leads to photophobia, glare, and poor vision in patients with congenital or trauma-induced iris damage. Commercial artificial iris lenses are static in nature to provide aesthetics without restoring the natural iris's dynamic response to light. A new photo-responsive artificial iris was therefore developed using a photochromic material with self-adaptive light transmission properties and encased in a transparent biocompatible polymer matrix. The implantable artificial iris was designed and engineered using Photopia, a class of photo-responsive materials (termed naphthopyrans) embedded in polyethylene. Photopia was reshaped into annular disks that were spin-coated with polydimethylsiloxane (PDMS) to form our artificial iris lens of controlled thickness. Activated by UV and blue light in approximately 5 seconds with complete reversal in less than 1 minute, the artificial iris demonstrates graded attenuation of up to 40% of visible and 60% of UV light. There optical characteristics are suitable to reversibly regulate the incident light intensity. In vitro cell culture experiments showed up to 60% cell death within 10 days of exposure to Photopia, but no significant cell death observed when cultured with the artificial iris with protective encapsulation. Nuclear magnetic resonance spectroscopy confirmed these results as there was no apparent leakage of potentially toxic photochromic material from the ophthalmic device. Our artificial iris lens mimics the functionality of the natural iris by attenuating light intensity entering the eye with its rapid reversible change in opacity and thus potentially providing an improved treatment option for patients with iris damage.

  20. Iris ultrastructure in patients with synechiae as revealed by in vivo laser scanning confocal microscopy : In vivo iris ultrastructure in patients with Synechiae by Laser Scanning Confocal Microscopy.

    PubMed

    Li, Ming; Cheng, Hongbo; Guo, Ping; Zhang, Chun; Tang, Song; Wang, Shusheng

    2016-04-26

    Iris plays important roles in ocular physiology and disease pathogenesis. Currently it is technically challenging to noninvasively examine the human iris ultrastructure in vivo. The purpose of the current study is to reveal human iris ultrastructure in patients with synechiae by using noninvasive in vivo laser scanning confocal microscopy (LSCM). The ultrastructure of iris in thirty one patients, each with synechiae but transparent cornea, was examined by in vivo LSCM. Five characteristic iris ultrastructures was revealed in patients with synechiae by in vivo LSCM, which include: 1. tree trunk-like structure; 2. tree branch/bush-like structure; 3. Fruit-like structure; 4. Epithelioid-like structure; 5. deep structure. Pigment granules can be observed as a loose structure on the top of the arborization structure. In iris-associated diseases with Tyndall's Phenomenon and keratic precipitates, the pigment particles are more likely to fall off from the arborization structure. The ultrastructure of iris in patients with synechiae has been visualized using in vivo LSCM. Five iris ultrastructures can be clearly observed, with some of the structures maybe disease-associated. The fall-off of the pigment particles may cause the Tyndall's Phenomenon positive. In vivo LSCM provides a non-invasive approach to observe the human iris ultrastructure under certain eye disease conditions, which sets up a foundation to visualize certain iris-associated diseases in the future.

  1. Doctor, where is my iris?

    PubMed

    Sophocleous, Sophocles

    2016-05-05

    Phacoemulsification cataract surgery with small clear corneal incision (CCI) is the standard of care for cataract treatment. Self-sealing, clear corneal wounds have been found to be stable and able to withstand high pressures. Nevertheless, there are a few cases published describing patients with previous cataract surgery and manually performed CCI who sustained blunt trauma with associated wound dehiscence, iris disinsertion and expulsion through the wound. The case described here demonstrates an eye that had traumatic aniridia post-blunt trauma, while the intraocular lens and the rest of the ocular structures remained intact. 2016 BMJ Publishing Group Ltd.

  2. Joint IRIS/PASSCAL UNAVCO Seismic and GPS Installations, Testing, and Development

    NASA Astrophysics Data System (ADS)

    Fowler, J.; Alvarez, M.; Beaudoin, B.; Jackson, M.; Feaux, K.; Ruud, O.; Andreatta, V.; Meertens, C.; Ingate, S.

    2002-12-01

    Future large-scale deformation initiatives such as EarthScope (http://www.earthscope.org/) will provide an opportunity for collocation and integration of GPS receivers and broadband and short period seismic instruments. Example integration targets include PBO backbone and cluster sites with USArray Transportable (Bigfoot) and Permanent Array. A GPS seismic integration and testing facility at the IRIS/PASSCAL Instrument Center in Socorro, NM is currently performing side-by-side testing of different seismometers, GPS receivers, communications hardware, power systems and data streaming software. One configuration tested uses an integrated VSAT data communications system and a broadband seismometer collocated with a geodetic quality GPS system. Data are routed through a VSAT hub and distributed to the UNAVCO Data Archive in Boulder and the IRIS Data Management Center in Seattle. Preliminary results indicate data availability approaching 100% with a maximum latency of 5 sec.

  3. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    PubMed

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    PubMed

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  5. Tuberculosis immune reconstitution inflammatory syndrome in A5221 STRIDE: timing, severity, and implications for HIV-TB programs.

    PubMed

    Luetkemeyer, Anne F; Kendall, Michelle A; Nyirenda, Mulinda; Wu, Xingye; Ive, Prudence; Benson, Constance A; Andersen, Janet W; Swindells, Susan; Sanne, Ian M; Havlir, Diane V; Kumwenda, Johnstone

    2014-04-01

    Earlier initiation of antiretroviral therapy (ART) in HIV-tuberculosis (TB) is associated with increased immune reconstitution inflammatory syndrome (IRIS). The severity, frequency, and complications of TB IRIS were evaluated in A5221, a randomized trial of earlier ART (within 2 weeks after TB treatment initiation) vs. later ART (8-12 weeks after TB treatment) in HIV-infected patients starting TB treatment. In 806 participants, TB IRIS was defined using published clinical criteria. Cases were classified as severe (hospitalization/death), moderate (corticosteroid use/invasive procedure), or mild (no hospitalization/procedures/steroids). Fisher exact, Wilcoxon, and log-rank tests were used for comparisons. TB IRIS occurred in 61 (7.6%) patients: 10.4% in earlier vs. 4.7% in later ART, 11.5% with CD4 <50 vs. 5.4% with CD4 ≥50 cells per cubic millimeter. The CD4/ART arm interaction was significant, P = 0.014, with 44.3% of TB IRIS occurring with CD4 <50 and earlier ART. TB IRIS occurred sooner with earlier vs. later ART initiation, at a median of 29 vs. 82 days after TB treatment initiation (P < 0.001). IRIS manifestations included lymphadenopathy (59.0%), constitutional symptoms (54.1%), and radiographic changes (41.0%); central nervous system TB IRIS was uncommon (6.6%). TB IRIS was mild in 27.9%, moderate in 41.0%, and severe in 31.1%. No TB IRIS-associated deaths occurred. IRIS management required ≥1 invasive procedures in 34.4%, hospitalization in 31.1%, and corticosteroids in 54.1%. TB IRIS was more frequent with earlier ART initiation and CD4 <50 cells per cubic millimeter. As ART is implemented earlier in HIV-TB coinfection, programs will require the diagnostic capabilities, clinical resources, and training necessary to manage TB IRIS.

  6. Quantitative study of the microvasculature and its endothelial cells in the porcine iris.

    PubMed

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-03-01

    The roles of the iris microvasculature have been increasingly recognised in the pathogenesis of glaucoma and cataract; however limited information exists regarding the iris microvasculature and its endothelium. This study quantitatively assessed the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining of the porcine iris. The temporal long posterior ciliary artery of 11 isolated porcine eyes was cannulated, perfusion-fixed and labelled using silver nitrate. The iris microvasculature was studied for its distribution, orders and endothelial morphometrics. The density of three layers of microvasculature was measured. Endothelial cell length and width were measured for each vessel order. The iris has an unusual vascular distribution which consisted of abundant large vessels in the middle of the iris stroma, branching over a relatively short distance to the microvasculature located in the superficial and deep stroma as well as the pupil edge. The average vascular density of the middle, superficial, and deep layers were 38.9 ± 1.93%, 10.9 ± 1.61% and 8.0 ± 0.79% respectively. Multiple orders of iris vessels (capillary, 6 orders of arteries, and 4 orders of veins) with relatively large capillary and input arteries (319.5 ± 25.6 μm) were found. Significant heterogeneity of vascular diameter and shape of the endothelia was revealed in different orders of the iris vasculature. Detailed information of topography and endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. The iris – a window into the genetics of common and rare eye diseases

    PubMed Central

    Morrison, Patrick J

    2010-01-01

    Visual examination, without instruments, of the eye allows inspection of the iris, sclera, cornea and, through the iris, some abnormalities of the lens and retina. Several hereditary disorders can easily be recognised by characteristic iris changes. This review discusses changes in the iris, visible lens anomalies, and changes in the cornea surrounding the iris. A genetic diagnosis can help with management of diseases. Some conditions are single gene disorders, some are chromosomal rearrangements, and some are abnormalities of fetal development. PMID:20844723

  8. Ionospheric TEC from the Turkish Permanent GNSS Network (TPGN) and comparison with ARMA and IRI models

    NASA Astrophysics Data System (ADS)

    Ansari, Kutubuddin; Panda, Sampad Kumar; Althuwaynee, Omar F.; Corumluoglu, Ozsen

    2017-09-01

    The present study investigates the ionospheric Total Electron Content (TEC) variations in the lower mid-latitude Turkish region from the Turkish Permanent GNSS Network (TPGN) and International GNSS Services (IGS) observations during the year 2016. The corresponding vertical TEC (VTEC) predicted by Auto Regressive Moving Average (ARMA) and International Reference Ionosphere 2016 (IRI-2016) models are evaluated to realize their effectiveness over the region. The spatial, diurnal and seasonal behavior of VTEC and the relative VTEC variations are modeled with Ordinary Least Square Estimator (OLSE). The spatial behavior of modeled result during March equinox and June solstice indicates an inverse relationship of VTEC with the longitude across the region. On the other hand, the VTEC variation during September equinox and December solstice including March equinox and June solstice are decreasing with increase in latitude. The GNSS observed and modeled diurnal variation of the VTEC show that the VTEC slowly increases with dawn, attains a broader duration of peak around 09.00 to 12.00 UT, and thereafter decreases gradually reaching minimum around 21.00 UT. The seasonal variation of VTEC shows an annual mode, maxima in equinox and minima in solstice. The average value of VTEC during the June solstice is with slightly higher value than the March equinox though variations during the latter season is more. Moreover, the study shows minimum average value during December solstice compared to June solstice at all stations. The comparative analysis demonstrates the prediction errors by OLSE, ARMA and IRI remaining between 0.23 to 1.17%, 2.40 to 4.03% and 24.82 to 25.79% respectively. Also, the observed VTEC seasonal variation has good agreement with OLSE and ARMA models whereas IRI-VTEC often underestimated the observed value at each location. Hence, the deviations of IRI estimated VTEC compared to ARMA and OLSE models claim further improvements in IRI model over the Turkish region. Although IRI estimations are well accepted over the mid-latitudes but the performance over the lower mid-latitudes is not satisfactory and needs further improvement. The long-term TEC data from the TPGN network can be incorporated in the IRI under laying database with appropriate calibration for further improvement of estimation accuracy over the region.

  9. Iris Freckles a Potential Biomarker for Chronic Sun Damage.

    PubMed

    Schwab, Christoph; Mayer, Christoph; Zalaudek, Iris; Riedl, Regina; Richtig, Markus; Wackernagel, Werner; Hofmann-Wellenhof, Rainer; Richtig, Georg; Langmann, Gerald; Tarmann, Lisa; Wedrich, Andreas; Richtig, Erika

    2017-05-01

    To investigate the role of sunlight exposure in iris freckles formation. We prospectively examined volunteers attending a skin cancer screening program conducted by ophthalmologists and dermatologists. Frequency and topographical variability of iris freckles were noted and associated with behavioral and dermatologic characteristics indicating high sun exposure. Six hundred thirty-two participants (n = 360; 57% female) were examined. Mean age of all participants was 38.4 ± 18.4 years (range, 4-84 years). Of all individuals, 76.1% (n = 481) exhibited at least one iris freckle. Most freckles were observed in the inferior temporal quadrant. The presence of iris freckles was associated with higher age (participants with iris freckles: 41.8 ± 16.8 years versus participants without iris freckles: 27.6 ± 19.2 years), a high number of sunburns during lifetime (>10: 31% vs. 19%), sunlight-damaged skin (26% vs. 11%), presence of actinic lentigines (72% vs. 45%), and a high total nevus body count (>10; 78% vs. 67%). The association of iris freckles, behavioral factors, and dermatologic findings, as well as the topographical distribution, indicate that sunlight exposure may trigger the formation of iris freckles. The evaluation of iris freckles offers an easily accessible potential biomarker, which might be helpful in indicating sun damage on the skin associated with cutaneous malignancies. Furthermore, the evaluation of iris freckles could also be helpful in understanding the role of sunlight in several ophthalmologic diseases.

  10. Morphological Alterations Within the Peripheral Fixation of the Iris Dilator Muscle in Eyes With Pigmentary Glaucoma

    PubMed Central

    Flügel-Koch, Cassandra M.; Tektas, Ozan Y.; Kaufman, Paul L.; Paulsen, Friedrich P.; Lütjen-Drecoll, Elke

    2014-01-01

    Purpose. To analyze the peripheral fixation of the iris dilator muscle in normal eyes and in eyes with pigmentary glaucoma (PG). Methods. Using 63 control eyes (age 18 months–99 years), the peripheral iris dilator was investigated by light microscopy, immunohistochemistry, and electron microscopy. Development was studied using 18 differently aged fetal eyes stained immunohistochemically against α-smooth muscle (SM) actin. The peripheral iris dilator muscle in PG was analyzed using semithin and ultrathin sections of six glutaraldehyde-fixed eyes from three donors aged 38, 62, and 74 years. Results. In normal eyes, the peripheral end of the iris dilator muscle is arranged in a sphincter-like manner. Arcade-shaped tendinous connections associated with myofibroblasts (iridial strands) anchor the iris dilator within the elastic–fibromuscular ciliary meshwork that also serves as fixation area for the elastic tendons of the inner ciliary muscle portions. The iridial strands are innervated and can adapt their length during accommodation. The PG eyes show incomplete circular bundles and iridial strands that are mainly anchored to the iris stroma and the flexible uveal parts of the trabecular meshwork. Conclusions. The normal anchorage of the peripheral iris dilator and its presumably neuronally regulated length adaptation stabilize the peripheral iris during accommodation. Insufficient fixation in PG could promote posterior bowing of the iris with rubbing against the zonular fibers and pigment liberation from the iris pigmented epithelium. PMID:24938519

  11. The voices of Iris: Cinematic representations of the aged woman and Alzheimer's disease in Iris (2001).

    PubMed

    Graham, Megan E

    2016-09-01

    Audiences must be critical of film representations of the aged woman living with Alzheimer's disease and of dangerous reinscriptions of stereotypical equations about ageing as deterioration. This paper analyses the representation and decline of the aged woman through the different voices of Iris Murdoch in Richard Eyre's film Iris (2001). Key vocal scenes are considered: On-screen encounters between young and aged Iris, vocal representations of dementia symptoms and silencing Iris as her disease progresses. Further, Iris' recurrent unaccompanied song, "The Lark in the Clear Air," compels audiences to "see" Iris with their ears more than with their eyes, exemplifying the representational power of sound in film. This paper is an appeal for increased debate about sonic representations of aged women, ageing and Alzheimer's disease and dementia in film. The significance of audiences' critical awareness and understanding about the social implications of these representations is discussed. © The Author(s) 2014.

  12. Iris Segmentation and Normalization Algorithm Based on Zigzag Collarette

    NASA Astrophysics Data System (ADS)

    Rizky Faundra, M.; Ratna Sulistyaningrum, Dwi

    2017-01-01

    In this paper, we proposed iris segmentation and normalization algorithm based on the zigzag collarette. First of all, iris images are processed by using Canny Edge Detection to detect pupil edge, then finding the center and the radius of the pupil with the Hough Transform Circle. Next, isolate important part in iris based zigzag collarette area. Finally, Daugman Rubber Sheet Model applied to get the fixed dimensions or normalization iris by transforming cartesian into polar format and thresholding technique to remove eyelid and eyelash. This experiment will be conducted with a grayscale eye image data taken from a database of iris-Chinese Academy of Sciences Institute of Automation (CASIA). Data iris taken is the data reliable and widely used to study the iris biometrics. The result show that specific threshold level is 0.3 have better accuracy than other, so the present algorithm can be used to segmentation and normalization zigzag collarette with accuracy is 98.88%

  13. Iris metastasis of gastric adenocarcinoma.

    PubMed

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah

    2016-03-08

    Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.

  14. First-Year Students' Priorities and Choices in STEM Studies--IRIS Findings from Germany and Austria

    ERIC Educational Resources Information Center

    Elster, D.

    2014-01-01

    IRIS (Interests and Recruitment in Science; http://iris.fp-7.org/about-iris/) is a European 7th framework project focusing on the challenge that only few young people in general, and women in particular, choose an education and career in science and technology. Project IRIS aims to contribute to the improvement of recruitment, retention and gender…

  15. Comparison of GPS derived TEC with the TEC predicted by IRI 2012 model in the southern Equatorial Ionization Anomaly crest within the Eastern Africa region

    NASA Astrophysics Data System (ADS)

    Sulungu, Emmanuel D.; Uiso, Christian B. S.; Sibanda, Patrick

    2018-04-01

    We have compared the TEC obtained from the IRI-2012 model with the GPS derived TEC data recorded within southern crest of the EIA in the Eastern Africa region using the monthly means of the 5 international quiet days for equinoxes and solstices months for the period of 2012 - 2013. GPS-derived TEC data have been obtained from the Africa array and IGS network of ground based dual-frequency GPS receivers from four stations (Kigali (1.95°S, 30.09°E; Geom. Lat. 11.63°S), Malindi (2.99°S, 40.19°E; Geom. Lat. 12.42°S), Mbarara (0.60°S, 30.74°E; Geom. Lat. 10.22°S) and Nairobi (1.22°S, 36.89°E; Geom. Lat. 10.69°S)) located within the EIA crest in this region. All the three options for topside Ne of IRI-2012 model and ABT-2009 for bottomside thickness have been used to compute the IRI TEC. Also URSI coefficients were considered in this study. These results are compared with the TEC estimated from GPS measurements. Correlation Coefficients between the two sets of data, the Root-Mean Square Errors (RMSE) of the IRI-TEC from the GPS-TEC, and the percentage RMSE of the IRI-TEC from the GPS-TEC have been computed. Our general results show that IRI-2012 model with all three options overestimates the GPS-TEC for all seasons and at all stations, and IRI-2001 overestimates GPS-TEC more compared with other options. IRI-Neq and IRI-01-corr are closely matching in most of the time. The observation also shows that, GPS TEC are underestimated by TEC from IRI model during noon hours, especially during equinoctial months. Further, GPS-TEC values and IRI-TEC values using all the three topside Ne options show very good correlation (above 0.8). On the other hand, the TEC using IRI-Neq and IRI-01- corr had smaller deviations from the GPS-TEC compared to the IRI-2001.

  16. PLATEAU IRIS--DIAGNOSIS AND TREATMENT.

    PubMed

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Relevant publications on plateau iris that were published until 2014. Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty.

  17. A study of multibiometric traits of identical twins

    NASA Astrophysics Data System (ADS)

    Sun, Zhenan; Paulino, Alessandra A.; Feng, Jianjiang; Chai, Zhenhua; Tan, Tieniu; Jain, Anil K.

    2010-04-01

    The increase in twin births has created a requirement for biometric systems to accurately determine the identity of a person who has an identical twin. The discriminability of some of the identical twin biometric traits, such as fingerprints, iris, and palmprints, is supported by anatomy and the formation process of the biometric characteristic, which state they are different even in identical twins due to a number of random factors during the gestation period. For the first time, we collected multiple biometric traits (fingerprint, face, and iris) of 66 families of twins, and we performed unimodal and multimodal matching experiments to assess the ability of biometric systems in distinguishing identical twins. Our experiments show that unimodal finger biometric systems can distinguish two different persons who are not identical twins better than they can distinguish identical twins; this difference is much larger in the face biometric system and it is not significant in the iris biometric system. Multimodal biometric systems that combine different units of the same biometric modality (e.g. multiple fingerprints or left and right irises.) show the best performance among all the unimodal and multimodal biometric systems, achieving an almost perfect separation between genuine and impostor distributions.

  18. Emotion Detection Deficits and Decreased Empathy in Patients with Alzheimer’s Disease and Parkinson’s Disease Affect Caregiver Mood and Burden

    PubMed Central

    Martinez, Maria; Multani, Namita; Anor, Cassandra J.; Misquitta, Karen; Tang-Wai, David F.; Keren, Ron; Fox, Susan; Lang, Anthony E.; Marras, Connie; Tartaglia, Maria C.

    2018-01-01

    Background: Changes in social cognition occur in patients with Alzheimer’s disease (AD) and Parkinson’s disease (PD) and can be caused by several factors, including emotion recognition deficits and neuropsychiatric symptoms (NPS). The aims of this study were to investigate: (1) group differences on emotion detection between patients diagnosed with AD or PD and their respective caregivers; (2) the association of emotion detection with empathetic ability and NPS in individuals with AD or PD; (3) caregivers’ depression and perceived burden in relation to patients’ ability to detect emotions, empathize with others, presence of NPS; and (4) caregiver’s awareness of emotion detection deficits in patients with AD or Parkinson. Methods: In this study, patients with probable AD (N = 25) or PD (N = 17), and their caregivers (N = 42), performed an emotion detection task (The Awareness of Social Inference Test—Emotion Evaluation Test, TASIT-EET). Patients underwent cognitive assessment, using the Behavioral Neurology Assessment (BNA). In addition, caregivers completed questionnaires to measure empathy (Interpersonal Reactivity Index, IRI) and NPS (Neuropsychiatric Inventory, NPI) in patients and self-reported on depression (Geriatric Depression Scale, GDS) and burden (Zarit Burden Interview, ZBI). Caregivers were also interviewed to measure dementia severity (Clinical Dementia Rating (CDR) Scale) in patients. Results: The results suggest that individuals with AD and PD are significantly worse at recognizing emotions than their caregivers. Moreover, caregivers failed to recognize patients’ emotion recognition deficits and this was associated with increased caregiver burden and depression. Patients’ emotion recognition deficits, decreased empathy and NPS were also related to caregiver burden and depression. Conclusions: Changes in emotion detection and empathy in individuals with AD and PD has implications for caregiver burden and depression and may be amenable to interventions with both patients and caregivers. PMID:29740312

  19. Scattering properties of ultrafast laser-induced refractive index shaping lenticular structures in hydrogels

    NASA Astrophysics Data System (ADS)

    Wozniak, Kaitlin T.; Germer, Thomas A.; Butler, Sam C.; Brooks, Daniel R.; Huxlin, Krystel R.; Ellis, Jonathan D.

    2018-02-01

    We present measurements of light scatter induced by a new ultrafast laser technique being developed for laser refractive correction in transparent ophthalmic materials such as cornea, contact lenses, and/or intraocular lenses. In this new technique, called intra-tissue refractive index shaping (IRIS), a 405 nm femtosecond laser is focused and scanned below the corneal surface, inducing a spatially-varying refractive index change that corrects vision errors. In contrast with traditional laser correction techniques, such as laser in-situ keratomileusis (LASIK) or photorefractive keratectomy (PRK), IRIS does not operate via photoablation, but rather changes the refractive index of transparent materials such as cornea and hydrogels. A concern with any laser eye correction technique is additional scatter induced by the process, which can adversely affect vision, especially at night. The goal of this investigation is to identify sources of scatter induced by IRIS and to mitigate possible effects on visual performance in ophthalmic applications. Preliminary light scattering measurements on patterns written into hydrogel showed four sources of scatter, differentiated by distinct behaviors: (1) scattering from scanned lines; (2) scattering from stitching errors, resulting from adjacent scanning fields not being aligned to one another; (3) diffraction from Fresnel zone discontinuities; and (4) long-period variations in the scans that created distinct diffraction peaks, likely due to inconsistent line spacing in the writing instrument. By knowing the nature of these different scattering errors, it will now be possible to modify and optimize the design of IRIS structures to mitigate potential deficits in visual performance in human clinical trials.

  20. IRiS: construction of ARG networks at genomic scales.

    PubMed

    Javed, Asif; Pybus, Marc; Melé, Marta; Utro, Filippo; Bertranpetit, Jaume; Calafell, Francesc; Parida, Laxmi

    2011-09-01

    Given a set of extant haplotypes IRiS first detects high confidence recombination events in their shared genealogy. Next using the local sequence topology defined by each detected event, it integrates these recombinations into an ancestral recombination graph. While the current system has been calibrated for human population data, it is easily extendible to other species as well. IRiS (Identification of Recombinations in Sequences) binary files are available for non-commercial use in both Linux and Microsoft Windows, 32 and 64 bit environments from https://researcher.ibm.com/researcher/view_project.php?id = 2303 parida@us.ibm.com.

  1. Simultaneous observations of Ellerman bombs by NST and IRIS

    NASA Astrophysics Data System (ADS)

    Kim, Y. H.; Yurchyshyn, V.; Cho, I. H.; Lee, J.; Park, Y. D.; Yang, H.; Ahn, K.; Goode, P.

    2015-12-01

    In this study, we present the simultaneous observations of Ellerman bombs made by New Solar Telescope (NST) of Big Bear Solar Observatory (BBSO) and Interface Region Imaging Spectrograph (IRIS) in space. The data obtained during joint NST-IRIS observations on 30 and 31 in July 2014. We observed two representative events on both days. The first one was a relatively weak Ellerman bomb occurred around 19:20 UT on 30 July 2014. IRIS observed this event by sit-and-stare mode thus we analyzed high cadence spectral data and slit-jaw data simultaneously. We found that this event was a hot explosion that occurred by magnetic reconnection in the lower atmosphere of the Sun. The second event was quite strong Ellerman bomb (20:20 UT on 31 July 2014) that is well observed by NST FISS (Fast Imaging Solar Spectrograph), while there was no IRIS spectral data. We had IRIS slit-jaw data only. The Ellerman bomb was clearly coincident with the IRIS brightening at the same location. Since the Ellerman bombs are usually believed to occur in the photosphere with no coronal emission, it should be explained its higher atmospheric emission in IRIS data. We will present the result of simultaneous observations by IRIS and NST instruments and discuss physical connection between Ellerman bombs and IRIS brightenings.

  2. Incidence and risk factors for immune reconstitution inflammatory syndrome in an ethnically diverse HIV type 1-infected cohort.

    PubMed

    Ratnam, I; Chiu, C; Kandala, N-B; Easterbrook, P J

    2006-02-01

    It is estimated that 10%-25% of patients who start highly active antiretroviral therapy (HAART) experience immune reconstitution inflammatory syndrome (IRIS). Our objective was to determine the incidence, clinical spectrum, and predictors of IRIS in an ethnically diverse cohort of patients initiating HAART. A retrospective study of all patients starting HAART between 1 January 2000 and 31 August 2002 at a human immunodeficiency virus (HIV) clinic in London was performed. All laboratory measurements and data on antiretroviral therapies were obtained from the clinic database. Medical records were reviewed to identify clinical events consistent with IRIS during the 6 months after HAART was initiated. A total of 199 patients were included, of whom 50.8% were male, 59.3% were black African, 29.1% were white, and 10.5% were black Caribbean. The median baseline CD4 cell count and HIV RNA load were 174x10(6) cells/L (interquartile range [IQR], 82-285x10(6) cells/L) and 37,830 copies/mL (IQR, 4809-149,653 copies/mL), respectively. Forty-four patients (22.7%) experienced an IRIS event at a median of 12 weeks after HAART initiation (IQR, 4-24 weeks after initiation); 22 events (50%) involved genital herpes, 10 (23%) involved genital warts, 4 (9.0%) involved molluscum contagiosum, and 4 (9.0%) involved varicella zoster virus infection. Five patients had mycobacterial infections, 4 had hepatitis B, 1 had Pneumocystis jirovecci infection, and 1 had Kaposi sarcoma. The strongest independent predictors of IRIS were younger age at initiation of HAART (P=.003), baseline CD4 cell percentage of <10% (odds ratio [OR], 2.97; IQR, 1.17-7.55) compared with >15%, and ratio of CD4 cell percentage to CD8 cell percentage of <0.15 (OR, 3.45; 95% confidence interval, 1.27-9.1) compared with >0.3. Approximately one-quarter of patients who start HAART experience an IRIS event. The majority are dermatological, in particular genital herpes and warts. Patients with advanced immunodeficiency at HAART initiation are at greatest risk of developing IRIS and should be appropriately screened and monitored.

  3. Comparison of Hyperspectral and Multispectral Satellites for Forest Alliance Classification in the San Francisco Bay Area

    NASA Astrophysics Data System (ADS)

    Clark, M. L.

    2016-12-01

    The goal of this study was to assess multi-temporal, Hyperspectral Infrared Imager (HyspIRI) satellite imagery for improved forest class mapping relative to multispectral satellites. The study area was the western San Francisco Bay Area, California and forest alliances (e.g., forest communities defined by dominant or co-dominant trees) were defined using the U.S. National Vegetation Classification System. Simulated 30-m HyspIRI, Landsat 8 and Sentinel-2 imagery were processed from image data acquired by NASA's AVIRIS airborne sensor in year 2015, with summer and multi-temporal (spring, summer, fall) data analyzed separately. HyspIRI reflectance was used to generate a suite of hyperspectral metrics that targeted key spectral features related to chemical and structural properties. The Random Forests classifier was applied to the simulated images and overall accuracies (OA) were compared to those from real Landsat 8 images. For each image group, broad land cover (e.g., Needle-leaf Trees, Broad-leaf Trees, Annual agriculture, Herbaceous, Built-up) was classified first, followed by a finer-detail forest alliance classification for pixels mapped as closed-canopy forest. There were 5 needle-leaf tree alliances and 16 broad-leaf tree alliances, including 7 Quercus (oak) alliance types. No forest alliance classification exceeded 50% OA, indicating that there was broad spectral similarity among alliances, most of which were not spectrally pure but rather a mix of tree species. In general, needle-leaf (Pine, Redwood, Douglas Fir) alliances had better class accuracies than broad-leaf alliances (Oaks, Madrone, Bay Laurel, Buckeye, etc). Multi-temporal data classifications all had 5-6% greater OA than with comparable summer data. For simulated data, HyspIRI metrics had 4-5% greater OA than Landsat 8 and Sentinel-2 multispectral imagery and 3-4% greater OA than HyspIRI reflectance. Finally, HyspIRI metrics had 8% greater OA than real Landsat 8 imagery. In conclusion, forest alliance classification was found to be a difficult remote sensing application with moderate resolution (30 m) satellite imagery; however, of the data tested, HyspIRI spectral metrics had the best performance relative to multispectral satellites.

  4. The role of BRCA1-IRIS in the development and progression of triple negative breast cancers in Egypt: possible link to disease early lesion.

    PubMed

    Bogan, Danielle; Meile, Lucio; El Bastawisy, Ahmed; Yousef, Hend F; Zekri, Abdel-Rahman N; Bahnassy, Abeer A; ElShamy, Wael M

    2017-05-12

    Breast cancer is the most globally diagnosed female cancer, with the triple negative breast cancer (TNBC) being the most aggressive subtype of the disease. In this study we aimed at comparing the effect of BRCA1-IRIS overexpression on the clinico-pathological characteristics in breast cancer patients with TNBC or non-TNBC in the largest comprehensive cancer center in Egypt. To reach this goal, we conducted an observational study at the National Cancer Institute (NCI), Cairo University (Cairo, Egypt). The data on all diagnosed breast cancer patients, between 2009 and 2012, were reviewed. BRCA1-IRIS expression measured using real time RT/PCR in these patients' tumor samples was correlated to tumor characteristics, such as to clinico-pathological features, therapeutic responses, and survival outcomes. 96 patients were enrolled and of these 45% were TNBC, and 55% were of other subtypes (hereafter, non-TNBC). All patients presented with invasive ductal carcinomas. No significant difference was observed for risk factors, such as age and menopausal status between the TNBC and the non-TNBC groups except after BRCA1-IRIS expression was factored in. The majority of the tumors in both groups were ≤5 cm at surgery (p = 0.013). However, in the TNBC group, ≤5 cm tumors were BRCA1-IRIS-overexpressing, whereas in the non-TNBC group they were BRCA1-IRIS-negative (p = 0.00007). Most of the TNBC patients diagnosed with grade 1 or 2 were BRCA1-IRIS-overexpressing, whereas non-TNBCs were IRIS-negative (p = 0.00035). No statistical significance was measured in patients diagnosed with grade 3 tumors. Statistically significant difference between TNBCs and non-TNBCs and tumor stage with regard to BRCA1-IRIS-overexpression was observed. Presence of axillary lymph node metastases was positively associated with BRCA1-IRIS overexpression in TNBC group, and with BRCA1-IRIS-negative status in the non-TNBC group (p = 0.00009). Relapse after chemotherapy (p < 0.00001), and local recurrence/distant metastasis after surgery (p = 0.0028) were more pronounced in TNBC patients with BRCA1-IRIS-overexpressing tumors compared to non-TNBC patients. Finally, decreased disease-free survival in TNBC/BRCA1-IRIS-overexpressing patients compared to TNBC/BRCA1-IRIS-negative patients, and decreased overall survival in TNBC as well as non-TNBC patients was driven by BRCA1-IRIS overexpression. TNBC/BRCA1-IRIS-overexpressing tumors are more aggressive than TNBC/BRCA1-IRIS-negative or non-TNBC/BRCA1-IRIS-overexpressing or both negative tumors. Further studies are warranted to define whether BRCA1-IRIS drives the early TNBC lesions growth and dissemination and whether it could be used as a diagnostic biomarker and/or therapeutic target for these lesions at an early stage setting.

  5. Monitoring of renal ischemia reperfusion injury in rabbits by ultrasonic contrast and its relationship with expression of VEGF in renal tissue.

    PubMed

    Hao, Peng

    2016-02-01

    To evaluate the renal ischemia reperfusion injury (IRI) in rabbits using the ultrasonic contrast technique and discuss the clinical value of ultrasonic contrast technique in the diagnosis of renal IRI by comparing the time-intensity curve of renal cortex and the expression of vascular endothelial growth factor (VEGF) of renal tissue. Twenty 3-month-old New Zealand rabbits were randomly divided into 4 groups, namely Ctrl group, IRI-12 h, IRI-24 h and IRI-48 h groups. The two dimensional gray-scale ultrasonography was employed to determine and mark the position of rabbit kidney. Rabbits were given the intraperitoneal anesthesia with 20% urethane with the dosage of 5 mL/kg. The aseptic operation was performed after the local skin disinfection in the area of both kidneys. The right kidney of animals in the control group was excised without any treatment for the left kidney. After excising the right kidney of animals in groups of IRI-12 h, IRI-24 h and IRI-48 h, the aneurysm clip was used to clip the renal pedicle vessel of left kidney, in order to simulate the ischemia. Because of the tissue ischemia, it could be seen that the color of kidney was changed from bright red to dark red, which indicated the successful modeling of ischemia. The aneurysm clip was released after one hour of maintaining the ischemia. Then the kidney turned out to be bright red from dark red, which indicated that the reperfusion was completed. Taking this moment as the time of ischemia reperfusion, the wound was stitched up. A total of 12, 24 and 36 h after the operation, the two-dimensional and color Doppler flow imaging and ultrasonic contrast were employed for the examination. The dynamic changes of ultrasonic contrast were recorded. The quantitative analysis software (QontraXt) was adopted to analyze the time-intensity curve of echo at different positions of renal cortex. After the ultrasonic contrast testing, rabbits were put to death. The renal cortex tissue was isolated and the tissue RNA and total protein were extracted respectively. Real-time PCR and western blotting were used to detect the VEGF and the Pearson product moment correlation coefficient was used to measure the linear relationship between these two variables. The ultrasonic contrast could clearly reflect the process of IRI. The results of testing at mRNA and protein level indicated that the expression of VEGF in IRI groups was significantly increased (P < 0.05) and the expression of VEGF was also increased by the time of reperfusion. There is the certain correlation between the expression of VEGF and process of IRI. The correlation coefficient between the ultrasonic contrast parameters of AT and TTP and the relative expression of VEGF is over 0.9, which indicates the relatively high correlation. But there is no significant difference in the change of perfusion peak intensity between groups, which has no correlation with the expression of VEGF. Copyright © 2016 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.

  6. Morphological alterations within the peripheral fixation of the iris dilator muscle in eyes with pigmentary glaucoma.

    PubMed

    Flügel-Koch, Cassandra M; Tektas, Ozan Y; Kaufman, Paul L; Paulsen, Friedrich P; Lütjen-Drecoll, Elke

    2014-06-17

    To analyze the peripheral fixation of the iris dilator muscle in normal eyes and in eyes with pigmentary glaucoma (PG). Using 63 control eyes (age 18 months-99 years), the peripheral iris dilator was investigated by light microscopy, immunohistochemistry, and electron microscopy. Development was studied using 18 differently aged fetal eyes stained immunohistochemically against α-smooth muscle (SM) actin. The peripheral iris dilator muscle in PG was analyzed using semithin and ultrathin sections of six glutaraldehyde-fixed eyes from three donors aged 38, 62, and 74 years. In normal eyes, the peripheral end of the iris dilator muscle is arranged in a sphincter-like manner. Arcade-shaped tendinous connections associated with myofibroblasts (iridial strands) anchor the iris dilator within the elastic-fibromuscular ciliary meshwork that also serves as fixation area for the elastic tendons of the inner ciliary muscle portions. The iridial strands are innervated and can adapt their length during accommodation. The PG eyes show incomplete circular bundles and iridial strands that are mainly anchored to the iris stroma and the flexible uveal parts of the trabecular meshwork. The normal anchorage of the peripheral iris dilator and its presumably neuronally regulated length adaptation stabilize the peripheral iris during accommodation. Insufficient fixation in PG could promote posterior bowing of the iris with rubbing against the zonular fibers and pigment liberation from the iris pigmented epithelium. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  7. Coloboma of the iris

    MedlinePlus

    ... enable JavaScript. Coloboma of the iris is a hole or defect of the iris of the eye. Most colobomas are present since birth (congenital). Considerations Coloboma of the iris can look like a second pupil or a black notch at the edge of the pupil. This ...

  8. PLATEAU IRIS – DIAGNOSIS AND TREATMENT

    PubMed Central

    Stefan, Cornel; Iliescu, Daniela Adriana; Batras, Mehdi; Timaru, Cristina Mihaela; De Simone, Algerino

    2015-01-01

    Objectives: The objective of our study was to review the current knowledge on the diagnosis and treatment options of plateau iris configuration and syndrome. Systematic review methodology: Relevant publications on plateau iris that were published until 2014. Conclusions: Plateau iris syndrome is a form of primary angle closure glaucoma caused by a large or anteriorly positioned ciliary body that leads to mechanical obstruction of trabecular meshwork. This condition is most often found in younger patients. Plateau iris has been considered an abnormal anatomic variant of the iris that can be diagnosed on ultrasound biomicroscopy or optical coherence tomography of anterior segment. Patients with plateau iris syndrome can be recognized by the lack of response in angle opening after iridotomy. The treatment of choice in these cases is argon laser peripheral iridoplasty PMID:27373109

  9. Transient expansion of activated CD8+ T cells characterizes tuberculosis-associated immune reconstitution inflammatory syndrome in patients with HIV: a case control study

    PubMed Central

    2013-01-01

    Background CD4+ T cell activation indicators have been reported to be a common phenomenon underlying diverse manifestations of immune reconstitution inflammatory syndrome (IRIS). However, we have found that a high frequency of circulating CD8+ T cells is a specific risk factor for mycobacterial IRIS. Therefore, we investigated whether CD8+ T cells from patients who develop TB IRIS were specifically activated. Methods We obtained PBMCs from HIV+ patients prior to and 4, 8, 12, 24, 52 and 104 weeks after initiating antiretroviral therapy. CD38 and HLADR expression on naive, central memory and effector memory CD8+ and CD4+ T cells were determined by flow cytometry. Absolute counts and frequencies of CD8+ T cell subsets were compared between patients who developed TB IRIS, who developed other IRIS forms and who remained IRIS-free. Results TB IRIS patients showed significantly higher counts of naive CD8+ T cells than the other groups at most time points, with a contraction of the effector memory subpopulation occurring later in the follow-up period. Activated (CD38+ HLADR+) CD8+ T cells from all groups decreased with treatment but transiently peaked in TB IRIS patients. This increase was due to an increase in activated naive CD8+ T cell counts during IRIS. Additionally, the CD8+ T cell subpopulations of TB IRIS patients expressed HLADR without CD38 more frequently and expressed CD38 without HLADR less frequently than cells from other groups. Conclusions CD8+ T cell activation is specifically relevant to TB IRIS. Different IRIS forms may involve different alterations in T cell subsets, suggesting different underlying inflammatory processes. PMID:23688318

  10. Differences in iris thickness among African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans.

    PubMed

    Lee, Roland Y; Huang, Guofu; Porco, Travis C; Chen, Yi-Chun; He, Mingguang; Lin, Shan C

    2013-12-01

    To evaluate the capability of iris thickness parameters to explain the difference in primary angle-closure glaucoma prevalence among the different racial groups. In this prospective study, 436 patients with open and narrow angles that met inclusion criteria were consecutively recruited from the UCSF general ophthalmology and glaucoma clinics to receive anterior segment optical coherence tomography imaging under standardized dark conditions. Images from 11 patients were removed due to poor visibility of the scleral spurs and the remaining images were analyzed using the Zhongshan Angle Assessment Program to assess the following measurements for the nasal and temporal angle of the anterior chamber: iris thickness at 750 and 2000 μm from the scleral spurs and the maximum iris thickness at middle one third of the iris. Iris thickness parameters were compared among and within the following 5 different racial groups: African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans. In comparing iris parameters among the open-angle racial groups, significant differences were found for nasal iris thickness at 750 and 2000 μm from the scleral spurs in which Chinese Americans displayed the highest mean value (P=0.01, P<0.0001). Among the narrow-angle racial groups, significant difference was found for nasal iris thickness at 2000 μm from the scleral in which Chinese Americans showed the highest mean value (P<0.0001). Significant difference was also found for temporal maximum iris thickness at middle one third of the iris in which African Americans exhibited the highest mean value (P=0.021). Iris thickness was modeled as a function of angle status using linear mixed-effects regression, adjusting for age, sex, pupil diameter, spherical equivalent, ethnicity, and the use of both eyes in patients. The iris thickness difference between the narrow-angle and open-angle groups was significant (P=0.0007). Racial groups that historically showed higher prevalence of primary angle-closure glaucoma possess thicker irides.

  11. Iris Damage Is Associated With Elevated Cytokine Levels in Aqueous Humor.

    PubMed

    Aketa, Naohiko; Yamaguchi, Takefumi; Suzuki, Terumasa; Higa, Kazunari; Yagi-Yaguchi, Yukari; Satake, Yoshiyuki; Tsubota, Kazuo; Shimazaki, Jun

    2017-05-01

    To evaluate the association between iris damage and cytokine levels in the aqueous humor (AqH). A total of 201 AqH samples from 201 consecutive patients (mean age 73.7 ± 10.6) were collected at the beginning of corneal transplantation or cataract surgery. Iris damage of each case was assessed from preoperative slit-lamp findings based on its severity. The subjects were classified into three groups: eyes without iris damage (126 eyes), eyes with mild iris damage (51 eyes), and eyes with severe iris damage (24 eyes). The levels of cytokines (IL-1α, IL-1β, IL-4, IL-6, IL-8, IL-10, IL-12p70, IL-13, IL-17a, interferon gamma-induced protein [IP]-10, monocyte chemotactic protein [MCP]-1, IFN-α, IFN-γ, macrophage inflammatory protein [MIP]-1α, MIP-1β, P-selectin, E-selectin, soluble intercellular adhesion molecule [sICAM]-1, TNF-α, and granulocyte-macrophage colony-stimulating factor [GM-CSF]) in AqH were measured by multiplex beads immunoassay. The levels of aqueous protein, IL-1α, IL-1β, IL-4, IL-6, IL-8, IL-10, IL-17A, MCP-1, TNF-α, E-selectin, P-selectin, and sICAM-1 in eyes with mild and severe iris damage were higher than in those without iris damage (P < 0.033). Multivariate analyses of clinical factors revealed that iris damage was associated with the history of complicated glaucoma, and the number of previous intraocular surgeries. The levels of AqH IL-6, IL-8, IL-13, MIP-1α, TNF-α, and sICAM-1 were significantly elevated in eyes with mild and severe iris damage in phakic eyes, and the levels of AqH IL-8 and sICAM-1 were significantly elevated in eyes with severe iris damage in pseudophakic eyes, compared with the eyes without iris damage (P < 0.045). Iris damage was associated with the elevation in the levels of aqueous protein and cytokines.

  12. Visualizing how Seismic Waves Propagate Across Seismic Arrays using the IRIS DMS Ground Motion Visualization (GMV) Products and Codes

    NASA Astrophysics Data System (ADS)

    Taber, J.; Bahavar, M.; Bravo, T. K.; Butler, R. F.; Kilb, D. L.; Trabant, C.; Woodward, R.; Ammon, C. J.

    2011-12-01

    Data from dense seismic arrays can be used to visualize the propagation of seismic waves, resulting in animations effective for teaching both general and advanced audiences. One of the first visualizations of this type was developed using Objective C code and EarthScope/USArray data, which was then modified and ported to the Matlab platform and has now been standardized and automated as an IRIS Data Management System (IRIS-DMS) data product. These iterative code developments and improvements were completed by C. Ammon, R. Woodward and M. Bahavar, respectively. Currently, an automated script creates Ground Motion Visualizations (GMVs) for all global earthquakes over magnitude 6 recorded by EarthScope's USArray Transportable Array (USArray TA) network. The USArray TA network is a rolling array of 400 broadband stations deployed on a uniform 70-km grid. These near real-time GMV visualizations are typically available for download within 4 hours or less of their occurrence (see: www.iris.edu/dms/products/usarraygmv/). The IRIS-DMS group has recently added a feature that allows users to highlight key elements within the GMVs, by providing an online tool for creating customized GMVs. This new interface allows users to select the stations, channels, and time window of interest, adjust the mapped areal extent of the view, and specify high and low pass filters. An online tutorial available from the IRIS Education and Public Outreach (IRIS-EPO) website, listed below, steps through a teaching sequence that can be used to explain the basic features of the GMVs. For example, they can be used to demonstrate simple concepts such as relative P, S and surface wave velocities and corresponding wavelengths for middle-school students, or more advanced concepts such as the influence of focal mechanism on waveforms, or how seismic waves converge at an earthquake's antipode. For those who desire a greater level of customization, including the ability to use the GMV framework with data sets not stored within the IRIS-DMS, the Matlab GMV code is now also available from the IRIS-DMS website. These GMV codes have been applied to sac-formatted data from the Quake Catcher Network (QCN). Through a collaboration between NSF-funded programs and projects (e.g., IRIS and QCN) we are striving to make these codes user friendly enough to be routinely incorporated in undergraduate and graduate seismology classes. In this way, we will help provide a research tool for students to explore never-looked-at-before data, similar to actual seismology research. As technology is advancing quickly, we now have more data than seismologists can easily examine. Given this, we anticipate students using our codes can perform a 'citizen scientist' role in that they can help us identify key signals within the unexamined vast data streams we are acquiring.

  13. IRIS Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE) (Public Comment Draft)

    EPA Science Inventory

    In September 2016, the U.S. Environmental Protection Agency's (USEPA) released the draft Integrated Risk Information System (IRIS) Toxicological Review of Ethyl Tertiary Butyl Ether (ETBE). Consistent with the 2013 IRIS Enhancements, draft IRIS assessments are released prior to e...

  14. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR BERYLLIUM AND COMPOUNDS

    EPA Science Inventory

    EPA's assessment of the noncancer health effects and carcinogenic potential of Beryllium was added to the IRIS database in 1998. The IRIS program is updating the IRIS assessment for Beryllium. This update will incorporate health effects information published since the last assess...

  15. 78 FR 18426 - Proposed Information Collection (IRIS) Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Proposed Information Collection (IRIS... through the Inquiry Routing and Information System (IRIS). DATES: Written comments and recommendations on... information technology. Title: Inquiry Routing and Information System (IRIS), VA Form 0873. OMB Control Number...

  16. The International Reference Ionosphere - Status 2013

    NASA Astrophysics Data System (ADS)

    Bilitza, Dieter

    2015-04-01

    This paper describes the latest version of the International Reference Ionosphere (IRI) model. IRI-2012 includes new models for the electron density and ion densities in the region below the F-peak, a storm-time model for the auroral E-region, an improved electron temperature model that includes variations with solar activity, and for the first time a description of auroral boundaries. In addition, the thermosphere model required for baseline neutral densities and temperatures was upgraded from MSIS-86 to the newer NRLMSIS-00 model and Corrected Geomagnetic coordinates (CGM) were included in IRI as an additional coordinate system for a better representation of auroral and polar latitudes. Ongoing IRI activities towards the inclusion of an improved model for the F2 peak height hmF2 are discussed as are efforts to develop a "Real-Time IRI". The paper is based on an IRI status report presented at the 2013 IRI Workshop in Olsztyn, Poland. The IRI homepage is at

  17. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    PubMed

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  18. Intracellular cytoskeleton and junction proteins of endothelial cells in the porcine iris microvasculature.

    PubMed

    Yang, Hongfang; Yu, Paula K; Cringle, Stephen J; Sun, Xinghuai; Yu, Dao-Yi

    2015-11-01

    Recently we reported studies of the iris microvasculature and its endothelial cells using intra-luminal micro-perfusion, fixation, and silver staining, suggesting that the iris vascular endothelium may be crucial for maintaining homeostasis in the ocular anterior segment. Here we present information regarding the intracellular structure and cell junctions of the iris endothelium. Thirty-seven porcine eyes were used for this study. The temporal long posterior ciliary artery was cannulated to assess the iris microvascular network and its endothelium using intra-luminal micro-perfusion, fixation, and staining with phalloidin for intracellular cytoskeleton f-actin, and with antibodies against claudin-5 and VE-cadherin for junction proteins. Nuclei were counterstained with Hoechst. The iris was flat-mounted for confocal imaging. The iris microvasculature was studied for its distribution, branch orders and endothelial morphometrics with endothelial cell length measured for each vessel order. Our results showed that morphometrics of the iris microvasculature was comparable with our previous silver staining. Abundant stress fibres and peripheral border staining were seen within the endothelial cells in larger arteries. An obvious decrease in cytoplasmic stress fibres was evident further downstream in the smaller arterioles, and they tended to be absent from capillaries and veins. Endothelial intercellular junctions throughout the iris vasculature were VE-cadherin and claudin-5 immuno-positive, indicating the presence of both adherent junctions and tight junctions between vascular endothelial cells throughout the iris microvasculature. Unevenness of claudin-5 staining was noted along the endothelial cell borders in almost every order of vessels, especially in veins and small arterioles. Our results suggest that significant heterogeneity of intracellular structure and junction proteins is present in different orders of the iris vasculature in addition to vascular diameter and shape of the endothelia. Detailed information of the topography and intracellular structure and junction proteins of the endothelium of the iris microvasculature combined with unique structural features of the iris may help us to further understand the physiological and pathogenic roles of the iris vasculature in relevant ocular diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Hydrogen-rich saline protects against small-scale liver ischemia-reperfusion injury by inhibiting endoplasmic reticulum stress.

    PubMed

    Li, Hui; Bai, Ge; Ge, Yansong; Zhang, Qianzhen; Kong, Xiangdong; Meng, Weijing; Wang, Hongbin

    2018-02-01

    Our research investigated the role of Hydrogen-rich saline (HRS) on the Endoplasmic reticulum stress (ERS) pathway and the effect of HRS on tissue injury in small Bama pig model of hepatic ischemia-reperfusion combined with partial hepatectomy. Eighteen healthy Bama miniature pigs were randomly divided equally into three groups: Sham, IRI, and HRS. Laparoscopic technique was employed to establish the model of hepatic ischemia-reperfusion combined with partial hepatectomy. HRS (10mL/kg) was injected into the portal vein 10min before perfusion. Histological examinations of the liver tissues were performed after HE staining. Additionally, transmission electron microscopy was performed to detect liver cell microstructure. Real-time PCR, Western blotting, and immunohistochemical staining were performed to analyze various ERS molecules including GRP78, p-eIF2α, XBP-1s, Full-length ATF6α, p-JNK, ATF4, and CHOP. We observed that HRS visibly improved ischemia-reperfusion injury (IRI) by reducing various parameters of ERS stress as evidenced by down-regulation of the mRNA as well as protein levels of GRP78, p-eIF2α, XBP-1s, p-JNK, and CHOP, and reducing the cleavage of Full-length ATF6α. Our study demonstrates that HRS protects the liver from IRI by inhibiting ERS. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Porcine cadaver iris model for iris heating during corneal surgery with a femtosecond laser

    NASA Astrophysics Data System (ADS)

    Sun, Hui; Fan, Zhongwei; Wang, Jiang; Yan, Ying; Juhasz, Tibor; Kurtz, Ron

    2015-03-01

    Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary study indicated that during typical surgical use, laser energy may pass beyond the cornea with potential effects on the iris. As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. Additionally, ex-vivo iris heating due to femtosecond laser irradiation was measured with an infrared thermal camera (Fluke corp. Everett, WA) as a validation of the simulation.

  1. Extending Iris: The VAO SED Analysis Tool

    NASA Astrophysics Data System (ADS)

    Laurino, O.; Busko, I.; Cresitello-Dittmar, M.; D'Abrusco, R.; Doe, S.; Evans, J.; Pevunova, O.

    2013-10-01

    Iris is a tool developed by the Virtual Astronomical Observatory (VAO) for building and analyzing Spectral Energy Distributions (SEDs). Iris was designed to be extensible, so that new components and models can be developed by third parties and then included at runtime. Iris can be extended in different ways: new file readers allow users to integrate data in custom formats into Iris SEDs; new models can be fitted to the data, in the form of template libraries for template fitting, data tables, and arbitrary Python functions. The interoperability-centered design of Iris and the Virtual Observatory standards and protocols can enable new science functionalities involving SED data.

  2. IRIS Toxicological Review of Ammonia Noncancer Inhalation ...

    EPA Pesticide Factsheets

    In September 2016, EPA finalized the IRIS assessment of Ammonia (Noncancer Inhalation). The Toxicological Review was reviewed internally by EPA and by other federal agencies and White House Offices before public release in June 2016. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science discussion materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Ammonia (Noncancer Inhalation) are posted on this site. Note: No major science comments were received on the Interagency Science Discussion Draft. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for ammonia. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effects that may result from chronic (or lifetime) exposure to chemicals in the environment. IRIS contains chemical-specific summaries of qualitative and quantitative health information in support of two steps of the risk assessment paradigm, i.e., hazard identification and dose-response evaluation. IRIS assessments are used in combination with specific situational exposure assessment information to evaluate potential public health risk associated with environmental contaminants.

  3. Iridoschisis: high frequency ultrasound imaging. Evidence for a genetic defect?

    PubMed Central

    Danias, J; Aslanides, I M; Eichenbaum, J W; Silverman, R H; Reinstein, D Z; Coleman, D J

    1996-01-01

    AIMS: To elucidate changes in the anatomy of the anterior chamber associated with iridoschisis, a rare form of iris atrophy, and their potential contribution to angle closure glaucoma. METHODS: Both eyes of a 71-year-old woman with bilateral iridoschisis and fibrous dysplasia and her asymptomatic 50-year-old daughter were scanned with a very high frequency (50 MHz) ultrasound system. RESULTS: The symptomatic patient exhibited diffuse changes in the iris stoma with an intact posterior iris pigmented layer in both eyes. These changes were clinically compatible with the lack of iris transillumination defects. Additionally, iris bowing with a resultant narrowing of the angle occurred. The asymptomatic daughter showed discrete, but less severe iris stromal changes. CONCLUSION: This is the first detailed study of high frequency ultrasonic imaging of the iris in iridoschisis. The observed structural changes suggest angle narrowing by forward bowing of the anterior iris stroma may be a mechanism of IOP elevation in this condition. The ultrasonic detection of iris changes in the asymptomatic daughter of the symptomatic patient and the association of iridoschisis with fibrous dysplasia suggest a possible genetic component in the pathogenesis of this condition. Images PMID:9059271

  4. Iris: Constructing and Analyzing Spectral Energy Distributions with the Virtual Observatory

    NASA Astrophysics Data System (ADS)

    Laurino, O.; Budynkiewicz, J.; Busko, I.; Cresitello-Dittmar, M.; D'Abrusco, R.; Doe, S.; Evans, J.; Pevunova, O.

    2014-05-01

    We present Iris 2.0, the latest release of the Virtual Astronomical Observatory application for building and analyzing Spectral Energy Distributions (SEDs). With Iris, users may read in and display SEDs inspect and edit any selection of SED data, fit models to SEDs in arbitrary spectral ranges, and calculate confidence limits on best-fit parameters. SED data may be loaded into the application from VOTable and FITS files compliant with the International Virtual Observatoy Alliance interoperable data models, or retrieved directly from NED or the Italian Space Agency Science Data Center; data in non-standard formats may also be converted within the application. Users may seamlessy exchange data between Iris and other Virtual Observatoy tools using the Simple Application Messaging Protocol. Iris 2.0 also provides a tool for redshifting, interpolating, and measuring integratd fluxes, and allows simple aperture corrections for individual points and SED segments. Custom Python functions, template models and template libraries may be imported into Iris for fitting SEDs. Iris may be extended through Java plugins; users can install third-party packages, or develop their own plugin using Iris' Software Development Kit. Iris 2.0 is available for Linux and Mac OS X systems.

  5. IRIS TOXICOLOGICAL REVIEW AND SUMMARY DOCUMENTS FOR 1,2,3-TRICHLOROPROPANE

    EPA Science Inventory

    EPA's assessment of the noncancer health effects and carcinogenic potential of 1,2,3-trichloropropane (TCP) was added to the IRIS database in 1990. The IRIS program is updating the IRIS assessment for TCP. This update will incorporate health effects information published since t...

  6. 75 FR 28856 - Agency Information Collection (IRIS) Activities Under OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-24

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Agency Information Collection (IRIS... Information System (IRIS). OMB Control Number: 2900-0619. Type of Review: Extension of a currently approved... veterans, dependents, and active duty personnel worldwide. IRIS allows a customer to submit questions...

  7. 75 FR 13208 - Proposed Information Collection (IRIS) Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0619] Proposed Information Collection (IRIS... submitted to VA through the Inquiry Routing and Information System (IRIS). DATES: Written comments and... (IRIS), VA Form 0873. OMB Control Number: 2900-0619. Type of Review: Extension of a currently approved...

  8. Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Dean L.; Rodriguez, Jose I.; Carroll, Brian A.

    The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed onmore » a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.« less

  9. The hippocampus, time and working memory.

    PubMed

    Rawlins, J N; Tsaltas, E

    1983-12-01

    Rats were trained on a discrete trial working memory leverpress alternation task, following hippocampal lesions (HC), cortical control lesions (CC) or sham operations (SO). Each trial consisted of a forced information response, for which a randomly selected lever was presented followed by a free choice stage, when both levers were presented. The rats were rewarded for pressing the lever which had not been presented at the information stage. When the information response was not rewarded, all rats learnt the task equally well at IRIs of up to 12.75 sec. When the information response was rewarded, the HC rats showed impaired choice accuracy. The extent of this impairment depended on the IRI, being greatest at long IRIs, and least at short ones. Varying the number of leverpresses required to complete the information response affected choice accuracy equivalently in all groups: all rats chose significantly less accurately when only one leverpress was required than when ten leverpresses were required. There was no interaction between the lesion treatments and the information response requirements. It was concluded that both the length of the IRI and the occurrence of events during the IRI determine the extent of the hippocampal lesion-induced performance deficit in working memory tasks. It is proposed that hippocampal damage disrupts an intermediate-term, high-capacity memory buffer, but leaves both a residual short-term memory system and the long-term retention of associations unaffected. This proposal leads to the prediction that reference memory tasks should also be affected by hippocampal lesions when a delay is introduced between making a response and being rewarded for doing so.

  10. Qualitative Assessment of Ultrasound Biomicroscopic Images Using Standard Photographs: The Liwan Eye Study

    PubMed Central

    Jiang, Yuzhen; Huang, Wenyong; Huang, Qunxiao; Zhang, Jian; Foster, Paul J.

    2010-01-01

    Objective. To classify anatomic features related to anterior chamber angles by a qualitative assessment system based on ultrasound biomicroscopy (UBM) images. Methods. Cases of primary angle-closure suspect (PACS), defined by pigmented trabecular meshwork that is not visible in two or more quadrants on static gonioscopy (cases) and systematically selected subjects (1 of every 10) who did not meet this criterion (controls) were enrolled during a population-based survey in Guangzhou, China. All subjects underwent UBM examination. A set of standard UBM images was used to qualitatively classify anatomic features related to the angle configuration, including iris thickness, iris convexity, iris angulation, ciliary body size, and ciliary process position. All analysis was conducted on right eye images. Results. Based on the qualitative grades, the difference in overall iris thickness between gonioscopically narrow eyes (n = 117) and control eyes (n = 57) was not statistically significant. The peripheral one third of the iris tended to be thicker in all quadrants of the PACS eyes, although the difference was statistically significant only in the superior quadrant (P = 0.008). No significant differences were found in the qualitative classifications of iris insertion, iris angulation, ciliary body size, and ciliary process position. The findings were similar when compared with the control group of eyes with wide angles in all quadrants. Conclusions. Basal iris thickness seems to be more relevant to narrow angle configuration than to overall iris thickness. Otherwise, the anterior rotation and size of the ciliary body, the iris insertion, and the overall iris thickness are comparable in narrow- and wide-angle eyes. PMID:19834039

  11. TREATMENT WITH THIDIAZURON IMPROVES OPENING AND VASE LIFE OF IRIS FLOWERS

    USDA-ARS?s Scientific Manuscript database

    The marketability of Dutch iris (Iris × hollandica) cut flowers is limited by their short display life and frequent failure to open fully. We tested the ability of thidiazuron (TDZ), a phenyl urea compound with cytokinin-like activity, to improve iris flower opening and longevity. A postharvest pu...

  12. Apical localization of glutamate in GLAST-1, glutamine synthetase positive ciliary body nonpigmented epithelial cells

    PubMed Central

    Langford, Marlyn P; Gosslee, Jeffrey M; Liang, Chanping; Chen, Dequan; Redens, Thomas B.; Welbourne, Tomas C

    2007-01-01

    The distribution of glutamate (Glu), the Glu transporter GLAST-1, and glutamine synthetase (GS) in human and monkey anterior uveal tissue, as well as serum (S) to aqueous humor (AH) Glu and glutamine (Gln) gradients were investigated. Cross-linked Glu (xGlu), GLAST-1, and GS were detected using the immunofluorescent antibody technique. S/AH Glu, Gln, and alanine (Ala) concentrations were quantified by high performance liquid chromatography. xGlu immunoreactivity was detected in melanocytes, posterior pigmented epithelial/dilator muscle cells, vascular endothelial cells, and lymphocytes of the iris, as well as the pigmented (PE) and nonpigmented epithelial (NPE) cells and muscle cells of ciliary body. xGlu immunoreactivity was highly concentrated at the apices of GLAST-1, GS positive ciliary body NPE cells, and in GLAST-1 positive iris melanocytes and iris dilator muscle cells. AH Glu concentrations were lower (p < 0.001), while Gln was higher in monkey (p = 0.01) and human cataractous (p = 0.15) AH than serum. The results indicate that Glu is concentrated within GLAST-1, GS positive NPE cells and are consistent with the suggestion that Glu and Gln concentrations in AH may be due in part to GLAST-1 and GS activity in iris and ciliary body epithelial cells. PMID:19668465

  13. QSAR Accelerated Discovery of Potent Ice Recrystallization Inhibitors

    NASA Astrophysics Data System (ADS)

    Briard, Jennie G.; Fernandez, Michael; de Luna, Phil; Woo, Tom. K.; Ben, Robert N.

    2016-05-01

    Ice recrystallization is the main contributor to cell damage and death during the cryopreservation of cells and tissues. Over the past five years, many small carbohydrate-based molecules were identified as ice recrystallization inhibitors and several were shown to reduce cryoinjury during the cryopreservation of red blood cells (RBCs) and hematopoietic stems cells (HSCs). Unfortunately, clear structure-activity relationships have not been identified impeding the rational design of future compounds possessing ice recrystallization inhibition (IRI) activity. A set of 124 previously synthesized compounds with known IRI activities were used to calibrate 3D-QSAR classification models using GRid INdependent Descriptors (GRIND) derived from DFT level quantum mechanical calculations. Partial least squares (PLS) model was calibrated with 70% of the data set which successfully identified 80% of the IRI active compounds with a precision of 0.8. This model exhibited good performance in screening the remaining 30% of the data set with 70% of active additives successfully recovered with a precision of ~0.7 and specificity of 0.8. The model was further applied to screen a new library of aryl-alditol molecules which were then experimentally synthesized and tested with a success rate of 82%. Presented is the first computer-aided high-throughput experimental screening for novel IRI active compounds.

  14. HyspIRI Measurements of Agricultural Systems in California: 2013-2015

    NASA Astrophysics Data System (ADS)

    Townsend, P. A.; Kruger, E. L.; Singh, A.; Jablonski, A. D.; Kochaver, S.; Serbin, S.

    2015-12-01

    During 2013-2015, NASA collected high-altitude AVIRIS hyperspectral and MASTER thermal infrared imagery across large swaths of California in support of the HyspIRI planning and prototyping activities. During these campaigns, we made extensive measurements of photosynthetic capacity—Vcmax and Jmax—and their temperature sensitivities across a range of sites, crop types and environmental conditions. Our objectives were to characterize the physiological diversity of agricultural vegetation in California and develop generalizable algorithms to map these physiological parameters across several image acquisitions, regardless of crop type and canopy temperatures. We employed AVIRIS imagery to scale and estimate the vegetation parameters and MASTER surface temperature to provide context, since physiology responds exponentially to leaf temperature. We demonstrate a segmentation approach to disentangling leaf and background soil temperature, and then illustrate our retrievals of Vcmax and Jmax during overflight conditions across a large number of the 2013-2015 HyspIRI acquisitions. Our results show >80% repeatability (R2) across split sample jack-knifing, with RMSEs within 15% of the range of our data. The approach was robust across crop types (e.g., grape, almond, pistachio, avocado, pomegranate, oats, peppers, citrus, date palm, alfalfa, melons, beets) and leaf temperatures. A global imaging spectroscopy system such as HyspIRI will offer unprecedented ability to monitor agricultural crop performance under widely varying surface conditions.

  15. A New Global Empirical Model of the Electron Temperature with the Inclusion of the Solar Activity Variations for IRI

    NASA Technical Reports Server (NTRS)

    Truhlik, V.; Triskova, L.

    2012-01-01

    A data-base of electron temperature (T(sub e)) comprising of most of the available LEO satellite measurements in the altitude range from 350 to 2000 km has been used for the development of a new global empirical model of T(sub e) for the International Reference Ionosphere (IRI). For the first time this will include variations with solar activity. Variations at five fixed altitude ranges centered at 350, 550, 850, 1400, and 2000 km and three seasons (summer, winter, and equinox) were represented by a system of associated Legendre polynomials (up to the 8th order) in terms of magnetic local time and the earlier introduced in vdip latitude. The solar activity variations of T(sub e) are represented by a correction term of the T(sub e) global pattern and it has been derived from the empirical latitudinal profiles of T(sub e) for day and night (Truhlik et al., 2009a). Comparisons of the new T(sub e) model with data and with the IRI 2007 Te model show that the new model agrees well with the data generally within standard deviation limits and that the model performs better than the current IRI T(sub e) model.

  16. QSAR Accelerated Discovery of Potent Ice Recrystallization Inhibitors

    PubMed Central

    Briard, Jennie G.; Fernandez, Michael; De Luna, Phil; Woo, Tom. K.; Ben, Robert N.

    2016-01-01

    Ice recrystallization is the main contributor to cell damage and death during the cryopreservation of cells and tissues. Over the past five years, many small carbohydrate-based molecules were identified as ice recrystallization inhibitors and several were shown to reduce cryoinjury during the cryopreservation of red blood cells (RBCs) and hematopoietic stems cells (HSCs). Unfortunately, clear structure-activity relationships have not been identified impeding the rational design of future compounds possessing ice recrystallization inhibition (IRI) activity. A set of 124 previously synthesized compounds with known IRI activities were used to calibrate 3D-QSAR classification models using GRid INdependent Descriptors (GRIND) derived from DFT level quantum mechanical calculations. Partial least squares (PLS) model was calibrated with 70% of the data set which successfully identified 80% of the IRI active compounds with a precision of 0.8. This model exhibited good performance in screening the remaining 30% of the data set with 70% of active additives successfully recovered with a precision of ~0.7 and specificity of 0.8. The model was further applied to screen a new library of aryl-alditol molecules which were then experimentally synthesized and tested with a success rate of 82%. Presented is the first computer-aided high-throughput experimental screening for novel IRI active compounds. PMID:27216585

  17. QSAR Accelerated Discovery of Potent Ice Recrystallization Inhibitors.

    PubMed

    Briard, Jennie G; Fernandez, Michael; De Luna, Phil; Woo, Tom K; Ben, Robert N

    2016-05-24

    Ice recrystallization is the main contributor to cell damage and death during the cryopreservation of cells and tissues. Over the past five years, many small carbohydrate-based molecules were identified as ice recrystallization inhibitors and several were shown to reduce cryoinjury during the cryopreservation of red blood cells (RBCs) and hematopoietic stems cells (HSCs). Unfortunately, clear structure-activity relationships have not been identified impeding the rational design of future compounds possessing ice recrystallization inhibition (IRI) activity. A set of 124 previously synthesized compounds with known IRI activities were used to calibrate 3D-QSAR classification models using GRid INdependent Descriptors (GRIND) derived from DFT level quantum mechanical calculations. Partial least squares (PLS) model was calibrated with 70% of the data set which successfully identified 80% of the IRI active compounds with a precision of 0.8. This model exhibited good performance in screening the remaining 30% of the data set with 70% of active additives successfully recovered with a precision of ~0.7 and specificity of 0.8. The model was further applied to screen a new library of aryl-alditol molecules which were then experimentally synthesized and tested with a success rate of 82%. Presented is the first computer-aided high-throughput experimental screening for novel IRI active compounds.

  18. Effects of a westernized lifestyle on the association between fasting serum nonesterified fatty acids and insulin secretion in Japanese men.

    PubMed

    Kamei, Nozomu; Yamane, Kiminori; Nakanishi, Shuhei; Ishida, Kazufumi; Ohtaki, Megu; Okubo, Masamichi; Kohno, Nobuoki

    2005-06-01

    The effects of the prolonged elevation of nonesterified fatty acid (NEFA) levels on insulin secretion have been controversial and thought to be sex-specific. To investigate the association between a westernized lifestyle and the effects of NEFA on insulin secretion in Japanese men, we examined 67 nondiabetic Japanese-American men and 220 nondiabetic native Japanese men who underwent a 75-g oral glucose tolerance test (OGTT). Most Japanese Americans we surveyed are genetically identical to Japanese living in Japan, but their lifestyle is more westernized. Sets of multiple regression analyses were performed to evaluate the relationship between the sum of the immunoreactive insulin (IRI) levels during the OGTT ((Sigma)IRI) and clinical parameters. Japanese Americans had higher levels of fasting IRI, (Sigma)IRI, and a higher insulin resistance index (homeostasis model assessment for insulin resistance [HOMA-IR]) than native Japanese, whereas there were no significant differences in fasting NEFA and triglyceride levels. A multiple regression analysis adjusted for age, fasting triglycerides, and body mass index (BMI) demonstrated that the fasting NEFA level was an independent determinant of the (Sigma)IRI only in Japanese-American men ( P = .001), but not in native Japanese men ( P = .054). Even when HOMA-IR was included in models instead of BMI, the NEFA level was a significant variable of (Sigma)IRI only in Japanese Americans ( P < .001), and not in native Japanese ( P = .098). In addition, a multiple regression analysis adjusted for age, fasting triglycerides, and BMI demonstrated that the fasting NEFA level was the only independent determinant of (Sigma)C-peptide in Japanese-American men ( P = .041). In conclusion, NEFA seems to be associated with insulin secretion independent of obesity or HOMA-IR. A westernized lifestyle may increase the effects of serum fasting NEFA levels on total insulin secretion after a glucose load in Japanese men.

  19. Implications of dynamic changes in miR-192 expression in ischemic acute kidney injury.

    PubMed

    Zhang, Lulu; Xu, Yuan; Xue, Song; Wang, Xudong; Dai, Huili; Qian, Jiaqi; Ni, Zhaohui; Yan, Yucheng

    2017-03-01

    Ischemia-reperfusion injury (IRI) is a major cause of acute kidney injury (AKI) with poor outcomes. While many important functions of microRNAs (miRNAs) have been identified in various diseases, few studies reported miRNAs in acute kidney IRI, especially the dynamic changes in their expression and their implications during disease progression. The expression of miR-192, a specific kidney-enriched miRNA, was assessed in both the plasma and kidney of IRI rats at different time points after kidney injury and compared to renal function and kidney histological changes. The results were validated in the plasma of the selected patients with AKI after cardiac surgery compared with those matched patients without AKI. The performance characteristics of miR-192 were summarized using area under the receiver operator characteristic (ROC) curves (AUC-ROC). MiRNA profiling in plasma led to the identification of 42 differentially expressed miRNAs in the IRI group compared to the sham group. MiR-192 was kidney-enriched and chosen for further validation. Real-time PCR showed that miR-192 levels increased by fourfold in the plasma and decreased by about 40% in the kidney of IRI rats. Plasma miR-192 expression started increasing at 3 h and peaked at 12 h, while kidney miR-192 expression started decreasing at 6 h and remained at a low level for 7 days after reperfusion. Plasma miR-192 level in patients with AKI increased at the time of ICU admission, was stable for 2 h and decreased after 24 h. AUC-ROC was 0.673 (95% CI: 0.540-0.806, p = 0.014). Plasma miR-192 expression was induced in a time-dependent manner after IRI in rats and patients with AKI after cardiac surgery, comparably to the kidney injury development and recovery process, and may be useful for the detection of AKI.

  20. [Phytoremediation of Petroleum Contaminated Soils with Iris pseudacorus L. and the Metabolic Analysis in Roots].

    PubMed

    Wang, Ya-nan; Cheng, Li-juan; Zhou, Qi-xing

    2016-04-15

    In this study, we performed a greenhouse pot-culture experiment to investigate the potential of a wild ornamental plant Iris pseudacorus L. in remediating petroleum contaminated soils from the Dagang Oilfield in Tianjin, China. The results suggested that Iris pseudacorus L. had great resistance to ≤ 40,000 mg · kg(⁻¹ of total petroleum hydrocarbons (TPHs). The removal rate of TPHs with concentrations of 10,000 mg · kg⁻¹, 20,000 mg · kg⁻¹ and 40,000 mg · kg⁻¹ in soils by Iris pseudacorus L. was 42.1%, 33.1% 31.2%, respectively, much higher than those in the corresponding controls (31.8%, 21.3% 11.9%, respectively) (P < 0.05). The root specific surface area of Iris pseudacorus L. was determined by the root scanner. The results suggested that TPHs with concentrations of 10,000 mg · kg⁻¹, 20,000 mg · kg⁻¹ and 40,000 mg · kg⁻¹ in soils increased the root specific surface area comparing with the controls. Additionally, the metabolic analysis showed that root metabolism changed to different degrees under the stress of TPHs, and the levels or species of metabolites had a significant change (P < 0.001). Furthermore, the results showed that 5 of 11 metabolites (VIP value > 1.2) with the root specific surface area from the PLS-DA model analysis, including ethanedioic acid, lactic acid, 2-butenedioic acid, phosphate and propanedioic acid, were positively correlated with the root specific surface area, but the others, gluconic acid, uridine, butanoic acid, maltose, 9,12-octadecadienoic acid, phenylalanine, were negatively correlated with it. In conclusion, using Iris pseudacorus L. to remediate petroleum contaminated soils is feasible, and the metabolic analysis in roots is useful to better understand the metabolic response of plants exposure to petroleum contaminated soils, and then reveals its remediated mechanisms.

  1. Mitochondria-targeted antioxidant MitoQ reduced renal damage caused by ischemia-reperfusion injury in rodent kidneys: Longitudinal observations of T2 -weighted imaging and dynamic contrast-enhanced MRI.

    PubMed

    Liu, Xiaoge; Murphy, Michael P; Xing, Wei; Wu, Huanhuan; Zhang, Rui; Sun, Haoran

    2018-03-01

    To investigate the effect of mitochondria-targeted antioxidant MitoQ in reducing the severity of renal ischemia-reperfusion injury (IRI) in rats using T 2 -weighted imaging and dynamic contrast-enhanced MRI (DCE-MRI). Ischemia-reperfusion injury was induced by temporarily clamping the left renal artery. Rats were pretreated with MitoQ or saline. The MRI examination was performed before and after IRI (days 2, 5, 7, and 14). The T 2 -weighted standardized signal intensity of the outer stripe of the outer medulla (OSOM) was measured. The unilateral renal clearance rate k cl was derived from DCE-MRI. Histopathology was evaluated after the final MRI examination. The standardized signal intensity of the OSOM on IRI kidneys with MitoQ were lower than those with saline on days 5 and 7 (P = 0.004, P < 0.001, respectively). K cl values of IRI kidneys with MitoQ were higher than those with saline at all time points (P = 0.002, P < 0.001, P = 0.001, P < 0.001). Histopathology showed that renal damage was the most predominant on the OSOM of IRI kidneys with saline, which was less obvious with MitoQ (P < 0.001). These findings demonstrate that MitoQ can reduce the severity of renal damage in rodent IRI models using T 2 -weighted imaging and DCE-MRI. Magn Reson Med 79:1559-1667, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  2. Mitochondria‐targeted antioxidant MitoQ reduced renal damage caused by ischemia‐reperfusion injury in rodent kidneys: Longitudinal observations of T 2‐weighted imaging and dynamic contrast‐enhanced MRI

    PubMed Central

    Liu, Xiaoge; Murphy, Michael P.; Xing, Wei; Wu, Huanhuan; Zhang, Rui

    2017-01-01

    Purpose To investigate the effect of mitochondria‐targeted antioxidant MitoQ in reducing the severity of renal ischemia‐reperfusion injury (IRI) in rats using T2‐weighted imaging and dynamic contrast‐enhanced MRI (DCE‐MRI). Methods Ischemia‐reperfusion injury was induced by temporarily clamping the left renal artery. Rats were pretreated with MitoQ or saline. The MRI examination was performed before and after IRI (days 2, 5, 7, and 14). The T2‐weighted standardized signal intensity of the outer stripe of the outer medulla (OSOM) was measured. The unilateral renal clearance rate kcl was derived from DCE‐MRI. Histopathology was evaluated after the final MRI examination. Results The standardized signal intensity of the OSOM on IRI kidneys with MitoQ were lower than those with saline on days 5 and 7 (P = 0.004, P < 0.001, respectively). Kcl values of IRI kidneys with MitoQ were higher than those with saline at all time points (P = 0.002, P < 0.001, P = 0.001, P < 0.001). Histopathology showed that renal damage was the most predominant on the OSOM of IRI kidneys with saline, which was less obvious with MitoQ (P < 0.001). Conclusions These findings demonstrate that MitoQ can reduce the severity of renal damage in rodent IRI models using T2‐weighted imaging and DCE‐MRI. Magn Reson Med 79:1559–1667, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:28608403

  3. A quantum-implementable neural network model

    NASA Astrophysics Data System (ADS)

    Chen, Jialin; Wang, Lingli; Charbon, Edoardo

    2017-10-01

    A quantum-implementable neural network, namely quantum probability neural network (QPNN) model, is proposed in this paper. QPNN can use quantum parallelism to trace all possible network states to improve the result. Due to its unique quantum nature, this model is robust to several quantum noises under certain conditions, which can be efficiently implemented by the qubus quantum computer. Another advantage is that QPNN can be used as memory to retrieve the most relevant data and even to generate new data. The MATLAB experimental results of Iris data classification and MNIST handwriting recognition show that much less neuron resources are required in QPNN to obtain a good result than the classical feedforward neural network. The proposed QPNN model indicates that quantum effects are useful for real-life classification tasks.

  4. Performance Evaluation of the IrisScan2200 Against Four Respirator Masks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WRIGHT, LARRY J.; TERRY, PRESTON L.

    2002-02-02

    The use of biometrics for the identification of individuals is becoming more prevalent in society and in the general government community. As the demand for these devices increases, it becomes necessary for the user community to have the facts needed to determine which device is the most appropriate for any given application. One such application is the use of biometric devices in areas where an individual may not be able to present a biometric feature that requires contact with the identifier (e.g., when dressed in anti-contamination suits or when wearing a respirator). This paper discusses a performance evaluation conducted onmore » the IrisScan2200 from Iridian Technologies to determine if it could be used in such a role.« less

  5. 2014 Summer Series - Robert Carvalho - Pursuing the Mysteries of the Sun: The IRIS Mission

    NASA Image and Video Library

    2014-06-19

    Pursuing the Mysteries of the Sun: The Interface Region Imaging Spectrograph (IRIS) Mission. Flight controllers from the IRIS mission will present their individual experiences on IRIS from development through the first year of flight. This will begin with a discussion of the unique nature of IRIS's mission and science, and how it fits into NASA's fleet of solar observatories. Next will be a discussion of the critical roles Ames contributed in the mission including spacecraft and flight software development, ground system development, and training for launch. This will be followed by experiences from launch, early operations, ongoing operations, and unusual operations experiences. The presentation will close with IRIS science imagery and questions.

  6. Applications of the IRI in Southern Africa

    NASA Astrophysics Data System (ADS)

    Coetzee, P. J.

    2004-01-01

    The IRI forms the basis of the Single Site Location Direction Finding networks of the South African Defence Force as well as theNational Intelligence Agency. It is also used in "Path Analysis" applications where the possible transmitter coverage is calculated. Another application of the IRI is in HF frequency predictions, especially for the South African Defence Force involved in peace keeping duties in Africa. The IRI is either used independently or in conjunction with vertical ionosondes. In the latter case the scaled F2 peak parameters (foF2, hmF2) are used as inputs to the IRI. The IRI thus gets "calibrated" to extend the area covered by the ionosonde(s). The IRI has proved to be a very important tool in South Africa and Africa in the fight against crime, drug trafficking, political instability and maintaining the peace in potentially unstable countries.

  7. IRIS Toxicological Review of Benzo[a]pyrene (Interagency ...

    EPA Pesticide Factsheets

    On August 21, 2013, the draft Toxicological Review of Benzo[a]pyrene and the draft charge to external peer reviewers were released for public review and comment. The Toxicological Review and charge were reviewed internally by EPA and by other federal agencies and White House Offices before public release. Consistent with the May 2009 IRIS assessment development process, all written comments on IRIS assessments submitted by other federal agencies and White House Offices are made publicly available. Accordingly, interagency comments and the interagency science consultation materials provided to other agencies, including interagency review drafts of the IRIS Toxicological Review of Benzo[a]pyrene and the charge to external peer reviewers, are posted on this site. EPA is undertaking an update of the Integrated Risk Information System (IRIS) health assessment for benzo[a]pyrene (BaP). The outcome of this project is an updated Toxicological Review and IRIS Summary for BaP that will be entered into the IRIS database.

  8. Challenges in diagnosis and management of Cryptococcal immune reconstitution inflammatory syndrome (IRIS) in resource limited settings.

    PubMed

    Musubire, A K; Meya, B D; Mayanja-Kizza, H; Lukande, R; Wiesner, L D; Bohjanen, P; R Boulware, R D

    2012-06-01

    In many resource-limited settings, cryptococcal meningitis (CM) contributes up to 20% of all deaths with further complications due to Immune Reconstitution Inflammatory Syndrome (IRIS). We present a case report on a patient who developed CM-IRIS and then subsequent CM-relapse with a fluconazole-resistant organism and then later CM-IRIS once again, manifesting as cystic cryptococcomas, hydrocephalus, and sterile CSF. In this case we, demonstrate that CM-IRIS and persistent low level cryptococcal infection are not mutually exclusive phenomena. The management of IRIS with corticosteroids may increase the risk of culture positive CM-relapse which may further increase the risk of recurrent IRIS and resulting complications including death. We also highlight the role of imaging and fluconazole resistance testing in patients with recurrent meningitis and the importance of CSF cultures in guiding treatment decisions.

  9. Corneal topography measurements for biometric applications

    NASA Astrophysics Data System (ADS)

    Lewis, Nathan D.

    The term biometrics is used to describe the process of analyzing biological and behavioral traits that are unique to an individual in order to confirm or determine his or her identity. Many biometric modalities are currently being researched and implemented including, fingerprints, hand and facial geometry, iris recognition, vein structure recognition, gait, voice recognition, etc... This project explores the possibility of using corneal topography measurements as a trait for biometric identification. Two new corneal topographers were developed for this study. The first was designed to function as an operator-free device that will allow a user to approach the device and have his or her corneal topography measured. Human subject topography data were collected with this device and compared to measurements made with the commercially available Keratron Piccolo topographer (Optikon, Rome, Italy). A third topographer that departs from the standard Placido disk technology allows for arbitrary pattern illumination through the use of LCD monitors. This topographer was built and tested to be used in future research studies. Topography data was collected from 59 subjects and modeled using Zernike polynomials, which provide for a simple method of compressing topography data and comparing one topographical measurement with a database for biometric identification. The data were analyzed to determine the biometric error rates associated with corneal topography measurements. Reasonably accurate results, between three to eight percent simultaneous false match and false non-match rates, were achieved.

  10. IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral (Scoping and Problem Formulation Materials)

    EPA Science Inventory

    In April 2018, EPA released the draft IRIS Assessment Plan for Ammonia and Ammonium Salts Noncancer Oral. An IRIS Assessment Plan (IAP) communicates to the public the plan for assessing each individual chemical and includes summary information on the IRIS Program’s sco...

  11. 78 FR 53138 - Notice of Extension of Public Comment Period on the Draft IRIS Carcinogenicity Assessment for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... Extension of Public Comment Period on the Draft IRIS Carcinogenicity Assessment for Ethylene Oxide and Addition of Ethylene Oxide to October IRIS Bimonthly Meeting Agenda AGENCY: Environmental Protection Agency... Ethylene Oxide to October IRIS Bimonthly Meeting Agenda. SUMMARY: EPA is announcing an extension of the...

  12. Mycobacterial Antigen Driven Activation of CD14++CD16− Monocytes Is a Predictor of Tuberculosis-Associated Immune Reconstitution Inflammatory Syndrome

    PubMed Central

    Andrade, Bruno B.; Singh, Amrit; Narendran, Gopalan; Schechter, Melissa E.; Nayak, Kaustuv; Subramanian, Sudha; Anbalagan, Selvaraj; Jensen, Stig M. R.; Porter, Brian O.; Antonelli, Lis R.; Wilkinson, Katalin A.; Wilkinson, Robert J.; Meintjes, Graeme; van der Plas, Helen; Follmann, Dean; Barber, Daniel L.; Swaminathan, Soumya; Sher, Alan; Sereti, Irini

    2014-01-01

    Paradoxical tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) is an aberrant inflammatory response occurring in a subset of TB-HIV co-infected patients initiating anti-retroviral therapy (ART). Here, we examined monocyte activation by prospectively quantitating pro-inflammatory plasma markers and monocyte subsets in TB-HIV co-infected patients from a South Indian cohort at baseline and following ART initiation at the time of IRIS, or at equivalent time points in non-IRIS controls. Pro-inflammatory biomarkers of innate and myeloid cell activation were increased in plasma of IRIS patients pre-ART and at the time of IRIS; this association was confirmed in a second cohort in South Africa. Increased expression of these markers correlated with elevated antigen load as measured by higher sputum culture grade and shorter duration of anti-TB therapy. Phenotypic analysis revealed the frequency of CD14++CD16− monocytes was an independent predictor of TB-IRIS, and was closely associated with plasma levels of CRP, TNF, IL-6 and tissue factor during IRIS. In addition, production of inflammatory cytokines by monocytes was higher in IRIS patients compared to controls pre-ART. These data point to a major role of mycobacterial antigen load and myeloid cell hyperactivation in the pathogenesis of TB-IRIS, and implicate monocytes and monocyte-derived cytokines as potential targets for TB-IRIS prevention or treatment. PMID:25275318

  13. Potential roles for BMP and Pax genes in the development of iris smooth muscle.

    PubMed

    Jensen, Abbie M

    2005-02-01

    The embryonic optic cup generates four types of tissue: neural retina, pigmented epithelium, ciliary epithelium, and iris smooth muscle. Remarkably little attention has focused on the development of the iris smooth muscle since Lewis ([1903] J. Am. Anat. 2:405-416) described its origins from the anterior rim of the optic cup neuroepithelium. As an initial step toward understanding iris smooth muscle development, I first determined the spatial and temporal pattern of the development of the iris smooth muscle in the chick by using the HNK1 antibody, which labels developing iris smooth muscle. HNK1 labeling shows that iris smooth muscle development is correlated in time and space with the development of the ciliary epithelial folds. Second, because neural crest is the only other neural tissue that has been shown to generate smooth muscle (Le Lievre and Le Douarin [1975] J. Embryo. Exp. Morphol. 34:125-154), I sought to determine whether iris smooth muscle development shares similarities with neural crest development. Two members of the BMP superfamily, BMP4 and BMP7, which may regulate neural crest development, are highly expressed by cells at the site of iris smooth muscle generation. Third, because humans and mice that are heterozygous for Pax6 mutations have no irides (Hill et al. [1991] Nature 354:522-525; Hanson et al. [1994] Nat. Genet. 6:168-173), I determined the expression of Pax6. I also examined the expression of Pax3 in the developing anterior optic cup. The developing iris smooth muscle coexpresses Pax6 and Pax3. I suggest that some of the eye defects caused by mutations in Pax6, BMP4, and BMP7 may be due to abnormal iris smooth muscle. Copyright 2004 Wiley-Liss, Inc.

  14. Irigenin sensitizes TRAIL-induced apoptosis via enhancing pro-apoptotic molecules in gastric cancer cells.

    PubMed

    Xu, Ying; Gao, Cheng-Cheng; Pan, Zhen-Guo; Zhou, Chuan-Wen

    2018-02-12

    Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) holds promising value for cancer therapy due to its capacity to induce apoptosis in cancer cells. Nevertheless, TRAIL therapy is greatly hampered by its resistance. Irigenin (Iri), isoflavonoids, can be isolated from the rhizome of Belamcanda chinensis, and has been shown anti-cancer properties. In this study, we explored if Iri could enhance TRAIL-regulated apoptosis in TRAIL resistant gastric cancer cells. Iri significantly potentiated TRAIL-triggered cytotoxicity. Iri alone and TRAIL alone showed no effective role in apoptosis induction, whereas combined treatment with Iri and TRAIL markedly induced apoptosis in cancer cells, as evidenced by the up-regulation of cleaved Caspase-8/-9/-3 and PARP. Additionally, the sensitization to TRAIL was along with the enhancement of pro-apoptotic proteins, including FAS-associated protein with death domain (FADD), death receptor 5 (DR5) and Bax. And suppressing FADD, DR5 and Bax by si RNA significantly reduced the apoptosis and enhanced the cell viability induced by the co-application of Iri and TRAIL. Moreover, the sensitization to TRAIL was accompanied by the decrease of Cellular-FLICE inhibitory protein (c-FLIP), Bcl-2 and Survivin. Additionally, Iri could sensitize TRAIL to produce reactive oxygen species (ROS). Pre-treatment of N-acetyl-cysteine (NAC), ROS scavenger, attenuated Iri plus TRAIL-induced apoptosis and improved cell viability. Finally, combination of Iri and TRAIL inhibited tumor growth in the xenograft model. Collectively, our present study gave new insights into the effects of Iri on potentiating TRAIL-sensitivity, and suggested that Iri could be a potential candidate for sensitizer of TRAIL-resistant cancer cell treatment. Copyright © 2018. Published by Elsevier Inc.

  15. Paradoxical Tuberculosis Immune Reconstitution Inflammatory Syndrome (TB-IRIS) in HIV Patients with Culture Confirmed Pulmonary Tuberculosis in India and the Potential Role of IL-6 in Prediction

    PubMed Central

    Porter, Brian O.; Chandrasekhar, Chockalingam; Venkatesan, Perumal; Menon, Pradeep A.; Subramanian, Sudha; Anbalagan, Selvaraj; Bhavani, Kannabiran P.; Sekar, Sathiyavelu; Padmapriyadarshini, Chandrasekaran; Kumar, Satagopan; Ravichandran, Narayanan; Raja, Krishnaraj; Bhanu, Kesavamurthy; Mahilmaran, Ayyamperumal; Sekar, Lakshmanan; Sher, Alan; Sereti, Irini; Swaminathan, Soumya

    2013-01-01

    Background The incidence, manifestations, outcome and clinical predictors of paradoxical TB-IRIS in patients with HIV and culture confirmed pulmonary tuberculosis (PTB) in India have not been studied prospectively. Methods HIV+ patients with culture confirmed PTB started on anti-tuberculosis therapy (ATT) were followed prospectively after anti-retroviral therapy (ART) initiation. Established criteria for IRIS diagnosis were used including decline in plasma HIV RNA at IRIS event. Pre-ART plasma levels of interleukin (IL)-6 and C-reactive protein (CRP) were measured. Univariate and multivariate logistic regression models were used to evaluate associations between baseline variables and IRIS. Results Of 57 patients enrolled, 48 had complete follow up data. Median ATT-ART interval was 28 days (interquartile range, IQR 14–47). IRIS events occurred in 26 patients (54.2%) at a median of 11 days (IQR: 7–16) after ART initiation. Corticosteroids were required for treatment of most IRIS events that resolved within a median of 13 days (IQR: 9–23). Two patients died due to CNS TB-IRIS. Lower CD4+ T-cell counts, higher plasma HIV RNA levels, lower CD4/CD8 ratio, lower hemoglobin, shorter ATT to ART interval, extra-pulmonary or miliary TB and higher plasma IL-6 and CRP levels at baseline were associated with paradoxical TB-IRIS in the univariate analysis. Shorter ATT to ART interval, lower hemoglobin and higher IL-6 and CRP levels remained significant in the multivariate analysis. Conclusion Paradoxical TB–IRIS frequently complicates HIV-TB therapy in India. IL-6 and CRP may assist in predicting IRIS events and serve as potential targets for immune interventions. PMID:23691062

  16. Interleukin-1 receptor antagonist, a biomarker of response to anti-TB treatment in HIV/TB co-infected patients.

    PubMed

    Nouhin, Janin; Pean, Polidy; Madec, Yoann; Chevalier, Mathieu F; Didier, Celine; Borand, Laurence; Blanc, François-Xavier; Scott-Algara, Daniel; Laureillard, Didier; Weiss, Laurence

    2017-05-01

    Despite the high frequency of tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) in human immunodeficiency virus (HIV)/TB co-infected patients, no diagnostic test is available. Here, we investigated whether monocyte/macrophage activation markers can predict TB-IRIS occurrence and if they are modulated by anti-TB treatment. Frozen plasma was obtained from 127 HIV/TB co-infected adults naïve for antiretroviral therapy, enrolled in the CAMELIA trial, 36 of whom developed TB-IRIS. Concentrations of IL-1Ra, sCD14, and sCD163 were measured at anti-TB treatment onset (baseline), after 8 weeks of anti-TB treatment and at TB-IRIS time. At baseline, IL-1Ra and sCD14 concentrations were similar in TB-IRIS and non-IRIS patients. sCD163 concentrations, although significantly higher in TB-IRIS patients, did not remain associated with TB-IRIS occurrence in multivariate analysis. At the time of TB-IRIS, patients displayed higher concentrations of IL-1Ra (p = 0.002) and sCD14 (p < 0.001). The most striking result was the significant decrease in IL-1Ra after 8 weeks of anti-TB treatment (median reduction: -63% (p < 0.0001)). None of the biomarkers tested was associated with TB-IRIS occurrence. However, repeated measurement of IL-1Ra could help for the diagnosis of TB-IRIS. The substantial reduction of IL-1Ra under treatment suggests that IL-1Ra could be a surrogate biomarker of anti-TB treatment response in HIV-infected patients. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  17. Contribution of Different Anatomical and Physiologic Factors to Iris Contour and Anterior Chamber Angle Changes During Pupil Dilation: Theoretical Analysis

    PubMed Central

    Jouzdani, Sara; Amini, Rouzbeh; Barocas, Victor H.

    2013-01-01

    Purpose. To investigate the contribution of three anatomical and physiologic factors (dilator thickness, dynamic pupillary block, and iris compressibility) to changes in iris configuration and anterior chamber angle during pupil dilation. Methods. A mathematical model of the anterior segment based on the average values of ocular dimensions was developed to simulate pupil dilation. To change the pupil diameter from 3.0 to 5.4 mm in 10 seconds, active dilator contraction was applied by imposing stress in the dilator region. Three sets of parameters were varied in the simulations: (1) a thin (4 μm, 1% of full thickness) versus a thick dilator (covering the full thickness iris) to quantify the effects of dilator anatomy, (2) in the presence (+PB) versus absence of pupillary block (−PB) to quantify the effect of dynamic motion of aqueous humor from the posterior to the anterior chamber, and (3) a compressible versus an incompressible iris to quantify the effects of iris volume change. Changes in the apparent iris–lens contact and angle open distance (AOD500) were calculated for each case. Results. The thin case predicted a significant increase (average 700%) in iris curvature compared with the thick case (average 70%), showing that the anatomy of dilator plays an important role in iris deformation during dilation. In the presence of pupillary block (+PB), AOD500 decreased 25% and 36% for the compressible and incompressible iris, respectively. Conclusions. Iris bowing during dilation was driven primarily by posterior location of the dilator muscle and by dynamic pupillary block, but the effect of pupillary block was not as large as that of the dilator anatomy according to the quantified values of AOD500. Incompressibility of the iris, in contrast, had a relatively small effect on iris curvature but a large effect on AOD500; thus, we conclude that all three effects are important. PMID:23482467

  18. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography

    PubMed Central

    Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.

    2016-01-01

    Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917

  19. Establishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography.

    PubMed

    Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P

    2016-01-01

    Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.

  20. Hand Grasping Synergies As Biometrics

    PubMed Central

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K.; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security. PMID:28512630

Top