Results of Performance Tests Performed on the John Watts WW Casing Connection on 7" Pipe
DOE Office of Scientific and Technical Information (OSTI.GOV)
John D. Watts
2000-02-01
Stress Engineering Services (SES) was contracted by Mr. John Watts to test his ''WW'' threaded connection developed for oilfield oil and gas service. This work was a continuation of testing performed by SES as reported in August of 1999. The connection design tested was identified as ''WW''. The samples were all integral (no coupled connections) and contained a wedge thread form with 90{sup o} flank angles relative to the pipe centerline. The wedge thread form is a variable width thread that primarily engages on the flanks. This thread form provides very high torque capacity and good stabbing ability and makeup.more » The test procedure selected for one of the samples was the newly written ISO 13679 procedure for full scale testing of casing and tubing connections, which is currently going through the ISO acceptance process. The ISO procedure requires a variety of tests that includes makeup/breakout testing, internal gas sealability/external water sealability testing with axial tension, axial compression, bending, internal gas thermal cycle tests and limit load (failure) tests. This test procedure was performed with one sample. Four samples were tested to failure. Table 1 contains a summary of the tasks performed by SES. The project started with the delivery of test samples by Mr. Watts. Pipe from the previous round of tests was used for the new samples. Figure 1 shows the structural and sealing results relative to the pipe body. Sample 1 was used to determine the torque capacity of the connection. Torque was applied to the capacity of SES's equipment which was 28,424 ft-lbs. From this, an initial recommended torque range of 7,200 to 8,800 ft-lbs. was selected. The sample was disassembled and while there was no galling observed in the threads, the end of the pin had collapsed inward. Sample 2 received three makeups. Breakouts 1 and 2 also had collapsing of the pin end, with no thread galling. From these make/breaks, it was decided to reduce the amount of lubricant applied to the connection by applying it to the box or pin only and reducing the amount applied. Samples 3 and 4 received one makeup only. Sample 5 initially received two make/breaks to test for galling resistance before final makeup, No galling was observed. Later, three additional make/breaks were performed with no pin end collapse and galling over 1/2 a thread occurring on one of the breakouts. During the make/break tests, the stabbing and hand tight makeup of the WW connection was found to be very easy and trouble free. There was no tendency to crossthread, even when stabbed at an angle, and it screwed together very smoothly up to hand tight. During power tight makeup, there was no heat generated in the box (as checked by hand contact) and no jerkiness associated with any of the makeups or breakouts. Sample 2 was tested in pure compression. The maximum load obtained was 1,051 kips and the connection was beginning to significantly deform as the sample buckled. Actual pipe yield was 1,226 kips. Sample 3 was capped-end pressure tested to failure. The capped-end yield pressure of the pipe was 16,572 psi and the sample began to leak at 12,000 psi. Sample 4 was tested in pure tension. The maximum load obtained was 978 kips and the connection failed by fracture at the pin critical section. Actual pipe yield was 1,226 kips. Sample 5 was tested in combined tension/compression and internal gas pressure. The sample was assembled, setup and tested four times. The first time was with a torque of 7,298 ft-lbs and the connection leaked halfway to ISO Load Point 2 with loads of 693 kips and 4,312 psi. The second time the torque was increased to 14,488 ft-lbs and a leak occurred at 849 kips and 9,400 psi, which was ISO Load Point 2. The third time the makeup torque was again increased, to 20,456 ft-lbs, and a leak occurred at 716 kips and 11,342 psi, ISO Load Point 4. The fourth test was with the same torque as before, 20,617 ft-lbs, and the connection successfully tested up to load step 56, ISO Load Point 6 (second round) before leaking at 354 kips and 11,876 psi. At this point, time and funds prevented additional testing to be performed.« less
Hsi, Wen C; Law, Aaron; Schreuder, Andreas N; Zeidan, Omar A
2014-08-01
An optical tracking and positioning system (OTPS) was developed to validate the software-driven isocentric (SDI) approach to control the six-degrees-of-freedom movement of a robotic couch. The SDI approach to movements rotating around a predefined isocenter, referred to as a GeoIso, instead of a mechanical pivot point was developed by the robot automation industry. With robotic couch-sag corrections for weight load in a traditional SDI approach, movements could be accurately executed for a GeoIso located within a 500 mm cubic volume on the couch for treatments. The accuracy of SDI movement was investigated using the OTPS. The GeoIso was assumed to align with the proton beam isocenter (RadIso) for gantry at the reference angle. However, the misalignment between GeoIso and RadIso was quantitatively investigated by measuring the displacements at various couch angles for a target placed at the RadIso at an initial couch angle. When circular target displacements occur on a plane, a relative isocenter shift (RIS) correction could be applied in the SDI movement to minimize target displacements. Target displacements at a fixed gantry angle without and with RIS correction were measured for 12 robotic couches. Target displacements for various gantry angles were performed on three couches in gantry rooms to study the gantry-induced RadIso shift. The RIS correction can also be applied for the RadIso shift. A new SDI approach incorporating the RIS correction with the couch sag is described in this study. In parallel, the accuracy of SDI translation movements for various weight loads of patients on the couch was investigated during positioning of patients for proton prostate treatments. For a fixed gantry angle, measured target displacements without RIS correction for couch rotations in the horizontal plane varied from 4 to 20 mm. However, measured displacements perpendicular to couch rotation plane were about 2 mm for all couches. Extracted misalignments of GeoIso and RadIso in the horizontal plane were about 10 mm for one couch and within 3 mm for the rest of couches. After applying the RIS correction, the residual target displacements for couch rotations were within 0.5 mm to RadIso for all couches. For various gantry angles, measured target location for each angle was within 0.5 mm to its excepted location by the preset RadIso shift. Measured target displacements for ± 30° of couch rotations were within 0.5 mm for gantry angles at 0° and 180°. Overall, nearly 85% of couch movements were within 0.5 mm in the horizontal plane and 0.7 mm vector distance from required displacements. The authors present an optical tracking methodology to quantify for software-driven isocentric movements of robotic couches. By applying proper RIS correction for misaligned GeoIso and RadIso for each couch, and the RadIso shifts for a moving gantry, residual target displacements for isocentric couch movements around the actual RadIso can be reduced to submillimeter tolerance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsi, Wen C., E-mail: Wen.Hsi@Mclaren.org, E-mail: Wenchien.hsi@sphic.org.cn; Zeidan, Omar A., E-mail: omar.zeidan@orlandohealth.com; Law, Aaron
Purpose: An optical tracking and positioning system (OTPS) was developed to validate the software-driven isocentric (SDI) approach to control the six-degrees-of-freedom movement of a robotic couch. Methods: The SDI approach to movements rotating around a predefined isocenter, referred to as a GeoIso, instead of a mechanical pivot point was developed by the robot automation industry. With robotic couch-sag corrections for weight load in a traditional SDI approach, movements could be accurately executed for a GeoIso located within a 500 mm cubic volume on the couch for treatments. The accuracy of SDI movement was investigated using the OTPS. The GeoIso wasmore » assumed to align with the proton beam isocenter (RadIso) for gantry at the reference angle. However, the misalignment between GeoIso and RadIso was quantitatively investigated by measuring the displacements at various couch angles for a target placed at the RadIso at an initial couch angle. When circular target displacements occur on a plane, a relative isocenter shift (RIS) correction could be applied in the SDI movement to minimize target displacements. Target displacements at a fixed gantry angle without and with RIS correction were measured for 12 robotic couches. Target displacements for various gantry angles were performed on three couches in gantry rooms to study the gantry-induced RadIso shift. The RIS correction can also be applied for the RadIso shift. A new SDI approach incorporating the RIS correction with the couch sag is described in this study. In parallel, the accuracy of SDI translation movements for various weight loads of patients on the couch was investigated during positioning of patients for proton prostate treatments. Results: For a fixed gantry angle, measured target displacements without RIS correction for couch rotations in the horizontal plane varied from 4 to 20 mm. However, measured displacements perpendicular to couch rotation plane were about 2 mm for all couches. Extracted misalignments of GeoIso and RadIso in the horizontal plane were about 10 mm for one couch and within 3 mm for the rest of couches. After applying the RIS correction, the residual target displacements for couch rotations were within 0.5 mm to RadIso for all couches. For various gantry angles, measured target location for each angle was within 0.5 mm to its excepted location by the preset RadIso shift. Measured target displacements for ±30° of couch rotations were within 0.5 mm for gantry angles at 0° and 180°. Overall, nearly 85% of couch movements were within 0.5 mm in the horizontal plane and 0.7 mm vector distance from required displacements. Conclusions: The authors present an optical tracking methodology to quantify for software-driven isocentric movements of robotic couches. By applying proper RIS correction for misaligned GeoIso and RadIso for each couch, and the RadIso shifts for a moving gantry, residual target displacements for isocentric couch movements around the actual RadIso can be reduced to submillimeter tolerance.« less
Tretola, M; Di Rosa, A R; Tirloni, E; Ottoboni, M; Giromini, C; Leone, F; Bernardi, C E M; Dell'Orto, V; Chiofalo, V; Pinotti, L
2017-08-01
The use of alternative feed ingredients in farm animal's diets can be an interesting choice from several standpoints, including safety. In this respect, this study investigated the safety features of selected former food products (FFPs) intended for animal nutrition produced in the framework of the IZS PLV 06/14 RC project by an FFP processing plant. Six FFP samples, both mash and pelleted, were analysed for the enumeration of total viable count (TVC) (ISO 4833), Enterobacteriaceae (ISO 21528-1), Escherichia coli (ISO 16649-1), coagulase-positive Staphylococci (CPS) (ISO 6888), presumptive Bacillus cereus and its spores (ISO 7932), sulphite-reducing Clostridia (ISO 7937), yeasts and moulds (ISO 21527-1), and the presence in 25 g of Salmonella spp. (ISO 6579). On the same samples, the presence of undesired ingredients, which can be identified as remnants of packaging materials, was evaluated by two different methods: stereomicroscopy according to published methods; and stereomicroscopy coupled with a computer vision system (IRIS Visual Analyzer VA400). All FFPs analysed were safe from a microbiological point of view. TVC was limited and Salmonella was always absent. When remnants of packaging materials were considered, the contamination level was below 0.08% (w/w). Of note, packaging remnants were found mainly from the 1-mm sieve mesh fractions. Finally, the innovative computer vision system demonstrated the possibility of rapid detection for the presence of packaging remnants in FFPs when combined with a stereomicroscope. In conclusion, the FFPs analysed in the present study can be considered safe, even though some improvements in FFP processing in the feeding plant can be useful in further reducing their microbial loads and impurity.
NASA Astrophysics Data System (ADS)
Doležel, Jiří; Novák, Drahomír; Petrů, Jan
2017-09-01
Transportation routes of oversize and excessive loads are currently planned in relation to ensure the transit of a vehicle through critical points on the road. Critical points are level-intersection of roads, bridges etc. This article presents a comprehensive procedure to determine a reliability and a load-bearing capacity level of the existing bridges on highways and roads using the advanced methods of reliability analysis based on simulation techniques of Monte Carlo type in combination with nonlinear finite element method analysis. The safety index is considered as a main criterion of the reliability level of the existing construction structures and the index is described in current structural design standards, e.g. ISO and Eurocode. An example of a single-span slab bridge made of precast prestressed concrete girders of the 60 year current time and its load bearing capacity is set for the ultimate limit state and serviceability limit state. The structure’s design load capacity was estimated by the full probability nonlinear MKP analysis using a simulation technique Latin Hypercube Sampling (LHS). Load-bearing capacity values based on a fully probabilistic analysis are compared with the load-bearing capacity levels which were estimated by deterministic methods of a critical section of the most loaded girders.
Comparison of prosthetic feet prescribed to active individuals using ISO standards.
Mason, Zachary D; Pearlman, Jon; Cooper, Rory A; Laferrier, Justin Z
2011-12-01
Little research has been done on the robustness of prosthetic feet prescribed to military personnel, and manufacturers are not required to test their products prior to sale. This is problematic because the prosthetic feet used by active individuals are subjected to loading conditions not seen in normal gait. To evaluate whether commercially available heavy-duty prosthetic feet intended for use by military personnel meet ISO 10328 standards. Bench testing of heavy-duty prosthetic feet using ISO 10328 standards. Prosthetic feet from three different manufacturers were tested according to ISO 10328 standards, using a testing frame fitted with axial load and displacement transducers. Pass/fail information was recorded as well as the stiffness and creep of each foot before and after cyclic testing. All feet passed the ISO 10328 standards at the highest loading level, and some significant differences were found within a given model of prosthesis when comparing stiffness and creep before and after cyclic testing. This study demonstrated that manufacturers of heavy-duty prosthetic feet adhere to the voluntary ISO 10328 standards. However, these standards may be insufficient because the tests simulate only idealized gait. Further development of the standards may be necessary to reproduce the circumstances that occur during extreme usage to ensure that prosthetic feet do not fail.
Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D
2014-08-01
Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.
La Barbera, Luigi; Galbusera, Fabio; Wilke, Hans-Joachim; Villa, Tomaso
2016-09-01
To discuss whether the available standard methods for preclinical evaluation of posterior spine stabilization devices can represent basic everyday life activities and how to compare the results obtained with different procedures. A comparative finite element study compared ASTM F1717 and ISO 12189 standards to validated instrumented L2-L4 segments undergoing standing, upper body flexion and extension. The internal loads on the spinal rod and the maximum stress on the implant are analysed. ISO recommended anterior support stiffness and force allow for reproducing bending moments measured in vivo on an instrumented physiological segment during upper body flexion. Despite the significance of ASTM model from an engineering point of view, the overly conservative vertebrectomy model represents an unrealistic worst case scenario. A method is proposed to determine the load to apply on assemblies with different anterior support stiffnesses to guarantee a comparable bending moment and reproduce specific everyday life activities. The study increases our awareness on the use of the current standards to achieve meaningful results easy to compare and interpret.
Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M
2012-01-01
A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.
Sasaki, Keisuke; Motoyama, Michiyo; Narita, Takumi; Chikuni, Koichi
2013-10-01
Texture and 'tenderness' in particular, is an important sensory characteristic for consumers' satisfaction of beef. Objective and detailed sensory measurements of beef texture have been needed for the evaluation and management of beef quality. This study aimed to apply the sensory scales defined in ISO11036:1994 to evaluate the texture of beef. Longissimus and Semitendinosus muscles of three Holstein steers cooked to end-point temperatures of 60°C and 72°C were subjected to sensory analyses by a sensory panel with expertise regarding the ISO11036 scales. For the sensory analysis, standard scales of 'chewiness' (9-points) and 'hardness' (7-points) were presented to the sensory panel with reference materials defined in ISO11036. As a result, both 'chewiness' and 'hardness' assessed according to the ISO11036 scales increased by increasing the cooking end-point temperature, and were different between Longissimus and Semitendinosus muscles. The sensory results were in good agreement with instrumental texture measurements. However, both texture ratings in this study were in a narrower range than the full ISO scales. For beef texture, ISO11036 scales for 'chewiness' and 'hardness' are useful for basic studies, but some alterations are needed for practical evaluation of muscle foods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Etingov, Pavel V.; Makarov, Yuri V.; Wu, Di
The document describes detailed uncertainty quantification (UQ) methodology developed by PNNL to estimate secure ranges of potential dynamic intra-hour interchange adjustments in the ISO-NE system and provides description of the dynamic interchange adjustment (DINA) tool developed under the same contract. The overall system ramping up and down capability, spinning reserve requirements, interchange schedules, load variations and uncertainties from various sources that are relevant to the ISO-NE system are incorporated into the methodology and the tool. The DINA tool has been tested by PNNL and ISO-NE staff engineers using ISO-NE data.
Mayton, Alan G.; Jobes, Christopher C.; Gallagher, Sean
2015-01-01
To further assess vibration exposure on haul trucks (HTs) and front-end wheel loaders (FELs), follow-up investigations were conducted at two US crushed stone operations. The purpose was to: 1) evaluate factors such as load/no-load conditions, speed, load capacity, vehicle age, and seat transmissibility relative to vibration exposure; 2) compare exposure levels with existing ISO/ANSI and EUGPG guidelines. Increasing HT speed increased recorded vibration at the chassis and seat as expected. Neither vehicle load nor vehicle speed increased transmissibility. Increasing HT size and age did show transmissibility decreasing. HT dominant-axis wRMS levels (most often the y-axis, lateral or side-to-side direction) were predominantly within the health guidance caution zone (HGCZ). However, several instances showed vibration dose value (VDV) above the exposure limit value (ELV) for the ISO/ANSI guidelines. VDV levels (all dominant x-axis or fore-aft) were within and above the HGCZ for the EUGPG and above the HGCZ for ISO/ANSI guidelines. PMID:26361493
NASA Astrophysics Data System (ADS)
Pakkratoke, M.; Sanponpute, T.
2017-09-01
The penetrated depth of the Rockwell hardness testing machine is normally not more than 0.260 mm. Using commercial load cell cannot achieve the proposed force calibration according to ISO 6508-2[1]. For these reason, the high stiffness load cell (HSL) was fabricated. Its obvious advantage is deformation less than 0.020 mm at 150 kgf maximum load applied. The HSL prototype was designed in concept of direct compression and then confirmed with finite element analysis, FEA. The results showed that the maximum deformation was lower than 0.012 mm at capacity.
Viscoelastic analysis of a dental metal-ceramic system
NASA Astrophysics Data System (ADS)
Özüpek, Şebnem; Ünlü, Utku Cemal
2012-11-01
Porcelain-fused-to-metal (PFM) restorations used in prosthetic dentistry contain thermal stresses which develop during the cooling phase after firing. These thermal stresses coupled with the stresses produced by mechanical loads may be the dominant reasons for failures in clinical situations. For an accurate calculation of these stresses, viscoelastic behavior of ceramics at high temperatures should not be ignored. In this study, the finite element technique is used to evaluate the effect of viscoelasticity on stress distributions of a three-point flexure test specimen, which is the current international standard, ISO 9693, to characterize the interfacial bond strength of metal-ceramic restorative systems. Results indicate that the probability of interfacial debonding due to normal tensile stress is higher than that due to shear stress. This conclusion suggests modification of ISO 9693 bond strength definition from one in terms of the shear stress only to that accounting for both normal and shear stresses.
Predicting Deformation Limits of Dual-Phase Steels Under Complex Loading Paths
Cheng, G.; Choi, K. S.; Hu, X.; ...
2017-04-05
Here in this study, the deformation limits of various DP980 steels are examined with the deformation instability theory. Under uniaxial tension, overall stress–strain curves of the material are estimated based on a simple rule of mixture (ROM) with both iso-strain and iso-stress assumptions. Under complex loading paths, an actual microstructure-based finite element (FE) method is used to resolve the deformation compatibilities explicitly between the soft ferrite and hard martensite phases. The results show that, for uniaxial tension, the deformation instability theory with iso-strain-based ROM can be used to provide the lower bound estimate of the uniform elongation (UE) for themore » various DP980 considered. Under complex loading paths, the deformation instability theory with microstructure-based FE method can be used in examining the effects of various microstructural features on the deformation limits of DP980 steels.« less
Predicting Deformation Limits of Dual-Phase Steels Under Complex Loading Paths
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, G.; Choi, K. S.; Hu, X.
The deformation limits of various DP980 steels are examined in this study with deformation instability theory. Under uniaxial tension, overall stress-strain curves of the material are estimated based on simple rule of mixture (ROM) with both iso-strain and iso-stress assumptions. Under complex loading paths, actual microstructure-based finite element (FE) method is used to explicitly resolve the deformation incompatibilities between the soft ferrite and hard martensite phases. The results show that, for uniaxial tension, the deformation instability theory with iso-strain-based ROM can be used to provide the lower bound estimate of the uniform elongation (UE) for the various DP980 considered. Undermore » complex loading paths, the deformation instability theory with microstructure-based FE method can be used in examining the effects of various microstructural features on the deformation limits of DP980 steels.« less
Predicting Deformation Limits of Dual-Phase Steels Under Complex Loading Paths
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, G.; Choi, K. S.; Hu, X.
Here in this study, the deformation limits of various DP980 steels are examined with the deformation instability theory. Under uniaxial tension, overall stress–strain curves of the material are estimated based on a simple rule of mixture (ROM) with both iso-strain and iso-stress assumptions. Under complex loading paths, an actual microstructure-based finite element (FE) method is used to resolve the deformation compatibilities explicitly between the soft ferrite and hard martensite phases. The results show that, for uniaxial tension, the deformation instability theory with iso-strain-based ROM can be used to provide the lower bound estimate of the uniform elongation (UE) for themore » various DP980 considered. Under complex loading paths, the deformation instability theory with microstructure-based FE method can be used in examining the effects of various microstructural features on the deformation limits of DP980 steels.« less
Grupp, Thomas M; Yue, James J; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm
2009-01-01
Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISO(initial) = 2.7 +/- 0.3 mg/million cycles. During the ASTM test period (10-15 million cycles) a gravimetric wear rate of 0.14 +/- 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients' daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method.
CERT Resilience Management Model (RMM) v1.1: Code of Practice Crosswalk Commercial Version 1.1
2011-10-01
ISO /IEC 24762:2008 (E) 6 2.8 ISO /IEC 27002 :2005 (E) 6 2.9 ISO /IEC 27005:2008 (E) 6 2.10 ISO /IEC 31000:2009 (E) 6 2.11...webstore.ansi.org/. 2.8 ISO /IEC 27002 :2005 (E) ISO /IEC 27002 , “Code of practice for information security management” [ ISO /IEC 2005b], broaches the full...scope of security management, at points touching upon both IT management and disaster recovery. ISO /IEC 27002 is part of a growing “27000
Mullett, L.B.; Loach, B.G.; Adams, G.L.
1958-06-24
>Loaded waveguides are described for the propagation of electromagnetic waves with reduced phase velocities. A rectangular waveguide is dimensioned so as to cut-off the simple H/sub 01/ mode at the operating frequency. The waveguide is capacitance loaded, so as to reduce the phase velocity of the transmitted wave, by connecting an electrical conductor between directly opposite points in the major median plane on the narrower pair of waveguide walls. This conductor may take a corrugated shape or be an aperature member, the important factor being that the electrical length of the conductor is greater than one-half wavelength at the operating frequency. Prepared for the Second U.N. International ConferThe importance of nuclear standards is duscussed. A brief review of the international callaboration in this field is given. The proposal is made to let the International Organization for Standardization (ISO) coordinate the efforts from other groups. (W.D.M.)
Ryu, Yeonsuk; Gracia-Lor, Emma; Bade, Richard; Baz-Lomba, J A; Bramness, Jørgen G; Castiglioni, Sara; Castrignanò, Erika; Causanilles, Ana; Covaci, Adrian; de Voogt, Pim; Hernandez, Felix; Kasprzyk-Hordern, Barbara; Kinyua, Juliet; McCall, Ann-Kathrin; Ort, Christoph; Plósz, Benedek G; Ramin, Pedram; Rousis, Nikolaos I; Reid, Malcolm J; Thomas, Kevin V
2016-12-15
Wastewater analysis has been demonstrated to be a complementary approach for assessing the overall patterns of drug use by a population while the full potential of wastewater-based epidemiology has yet to be explored. F 2 -isoprostanes are a prototype wastewater biomarker to study the cumulative oxidative stress at a community level. In this work, 8-iso-prostaglandin F 2α (8-iso-PGF 2α ) was analysed in raw 24 h-composite wastewater samples collected from 4 Norwegian and 7 other European cities in 2014 and 2015. Using the same samples, biomarkers of alcohol (ethyl sulfate) and tobacco (trans-3'-hydroxycotinine) use were also analysed to investigate any possible correlation between 8-iso-PGF 2α and the consumption of the two drugs. The estimated per capita daily loads of 8-iso-PGF 2α in the 11 cities ranged between 2.5 and 9.9 mg/day/1000 inhabitants with a population-weighted mean of 4.8 mg/day/1000 inhabitants. There were no temporal trends observed in the levels of 8-iso-PGF 2α , however, spatial differences were found at the inter-city level correlating to the degree of urbanisation. The 8-iso-PGF 2α mass load was found to be strongly associated with that of trans-3'-hydroxycotinine while it showed no correlation with ethyl sulfate. The present study shows the potential for 8-iso-PGF 2α as a wastewater biomarker for the assessment of community public health.
NASA Astrophysics Data System (ADS)
Ryu, Yeonsuk; Gracia-Lor, Emma; Bade, Richard; Baz-Lomba, J. A.; Bramness, Jørgen G.; Castiglioni, Sara; Castrignanò, Erika; Causanilles, Ana; Covaci, Adrian; de Voogt, Pim; Hernandez, Felix; Kasprzyk-Hordern, Barbara; Kinyua, Juliet; McCall, Ann-Kathrin; Ort, Christoph; Plósz, Benedek G.; Ramin, Pedram; Rousis, Nikolaos I.; Reid, Malcolm J.; Thomas, Kevin V.
2016-12-01
Wastewater analysis has been demonstrated to be a complementary approach for assessing the overall patterns of drug use by a population while the full potential of wastewater-based epidemiology has yet to be explored. F2-isoprostanes are a prototype wastewater biomarker to study the cumulative oxidative stress at a community level. In this work, 8-iso-prostaglandin F2α (8-iso-PGF2α) was analysed in raw 24 h-composite wastewater samples collected from 4 Norwegian and 7 other European cities in 2014 and 2015. Using the same samples, biomarkers of alcohol (ethyl sulfate) and tobacco (trans-3‧-hydroxycotinine) use were also analysed to investigate any possible correlation between 8-iso-PGF2α and the consumption of the two drugs. The estimated per capita daily loads of 8-iso-PGF2α in the 11 cities ranged between 2.5 and 9.9 mg/day/1000 inhabitants with a population-weighted mean of 4.8 mg/day/1000 inhabitants. There were no temporal trends observed in the levels of 8-iso-PGF2α, however, spatial differences were found at the inter-city level correlating to the degree of urbanisation. The 8-iso-PGF2α mass load was found to be strongly associated with that of trans-3‧-hydroxycotinine while it showed no correlation with ethyl sulfate. The present study shows the potential for 8-iso-PGF2α as a wastewater biomarker for the assessment of community public health.
Nässelqvist, Mattias; Gustavsson, Rolf; Aidanpää, Jan-Olov
2013-07-01
It is important to monitor the radial loads in hydropower units in order to protect the machine from harmful radial loads. Existing recommendations in the standards regarding the radial movements of the shaft and bearing housing in hydropower units, ISO-7919-5 (International Organization for Standardization, 2005, "ISO 7919-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Rotating Shafts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland) and ISO-10816-5 (International Organization for Standardization, 2000, "ISO 10816-5: Mechanical Vibration-Evaluation of Machine Vibration by Measurements on Non-Rotating Parts-Part 5: Machine Sets in Hydraulic Power Generating and Pumping Plants," Geneva, Switzerland), have alarm levels based on statistical data and do not consider the mechanical properties of the machine. The synchronous speed of the unit determines the maximum recommended shaft displacement and housing acceleration, according to these standards. This paper presents a methodology for the alarm and trip levels based on the design criteria of the hydropower unit and the measured radial loads in the machine during operation. When a hydropower unit is designed, one of its design criteria is to withstand certain loads spectra without the occurrence of fatigue in the mechanical components. These calculated limits for fatigue are used to set limits for the maximum radial loads allowed in the machine before it shuts down in order to protect itself from damage due to high radial loads. Radial loads in hydropower units are caused by unbalance, shape deviations, dynamic flow properties in the turbine, etc. Standards exist for balancing and manufacturers (and power plant owners) have recommendations for maximum allowed shape deviations in generators. These standards and recommendations determine which loads, at a maximum, should be allowed before an alarm is sent that the machine needs maintenance. The radial bearing load can be determined using load cells, bearing properties multiplied by shaft displacement, or bearing bracket stiffness multiplied by housing compression or movement. Different load measurement methods should be used depending on the design of the machine and accuracy demands in the load measurement. The methodology presented in the paper is applied to a 40 MW hydropower unit; suggestions are presented for the alarm and trip levels for the machine based on the mechanical properties and radial loads.
Villa, Tomaso; La Barbera, Luigi; Galbusera, Fabio
2014-04-01
Preclinical evaluation of the long-term reliability of devices for lumbar fixation is a mandatory activity before they are put into market. The experimental setups are described in two different standards edited by the International Organization for Standardization (ISO) and the American Society for Testing Materials (ASTM), but the evaluation of the suitability of such tests to simulate the actual loading with in vivo situations has never been performed. To calculate through finite element (FE) simulations the stress in the rods of the fixator when subjected to ASTM and ISO standards. To compare the calculated stresses arising in the same fixator once it has been virtually mounted in a physiological environment and loaded with physiological forces and moments. FE simulations and validation experimental tests. FE models of the ISO and ASTM setups were created to conduct simulations of the tests prescribed by standards and calculate stresses in the rods. Validation of the simulations were performed through experimental tests; the same fixator was virtually mounted in an L2-L4 FE model of the lumbar spine and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between FE simulations and experimental tests showed good agreement between results obtained using the two methodologies, thus confirming the suitability of the FE method to evaluate stresses in the device in different loading situations. The usage of a physiological load with ASTM standard is impossible due to the extreme severity of the ASTM configuration; in this circumstance, the presence of an anterior support is suggested. Also, ISO prescriptions, although the choice of the setup correctly simulates the mechanical contribution of the discs, seem to overstress the device as compared with a physiological loading condition. Some daily activities, other than walking, can induce a further state of stress in the device that should be taken into account in setting up new experimental procedures. ISO standard loading prescriptions seems to be more severe than the expected physiological ones. The ASTM standard should be completed by including some anterior supporting device and declaring the value of the load to be imposed. Moreover, a further enhancement of standards would be simulating other movements representative of daily activities different from walking. Copyright © 2014 Elsevier Inc. All rights reserved.
Yue, James J.; Garcia, Rolando; Basson, Janet; Schwiesau, Jens; Fritz, Bernhard; Blömer, Wilhelm
2008-01-01
Wear simulation is an essential pre-clinical method to predict the mid- and long-term clinical wear behavior of newly introduced devices for total disc arthroplasty. The main requirement of a suitable method for spinal wear simulation has to be the ability to distinguish between design concepts and allow for a direct comparison of predicate devices. The objective of our study was to investigate the influence of loading and kinematic patterns based on two different protocols for spinal wear simulation (ISO/FDIS 18192-1 (2006) and ASTM F2423-05). In vitro wear simulation was performed with six activ® L lumbar artificial disc devices (Aesculap Tuttlingen, Germany). The applied kinematic pattern of movement was multidirectional for ISO (elliptic track) and unidirectional with a curvilinear shape for ASTM. Testing was done for 10 million cycles in the ISO loading mode and afterwards with the same specimens for 5 million cycles according to the ASTM protocol with a customized six-station servohydraulic spinal wear simulator (EndoLab Thansau, Germany). Gravimetrical and geometrical wear assessment, a slide track analysis correlated to an optical surface characterization, and an estimation of particle size and morphology were performed. The gravimetric wear rate for the first 10 million cycles was ISOinitial = 2.7 ± 0.3 mg/million cycles. During the ASTM test period (10–15 million cycles) a gravimetric wear rate of 0.14 ± 0.06 mg/million cycles was estimated. The wear rates between the ISO and ASTM driven simulations differ substantially (approximately 20-fold) and statistical analysis demonstrates a significant difference (p < 0.001) between the test groups. The main explanation of divergency between ISO and ASTM driven wear simulations is the multidirectional pattern of movement described in the ISO document resulting in a cross-shear stress on the polyethylene material. Due to previous retrieval observations, it seems to be very unlikely that a lumbar artificial disc is loaded with a linear wear path.Testing according to ASTM F2423-05 with pure unidirectional motion does not reflect the kinematics of TDA patients‘ daily activities. Based on our findings it seems to be more reliable to predict the clinical wear behavior of an artificial disc replacement using the ISO/FDIS 18192-1 method. PMID:19050942
Tanimoto, Yasuhiro; Nagakura, Manamu; Nishiyama, Norihiro
2018-02-21
The purpose of this study was to investigate the combined effects of fiber loading and pigmentation on the color differences and flexural properties of glass fiber-reinforced thermoplastics (GFRTPs), for use in non-metal clasp dentures (NMCDs). The GFRTPs consisted mainly of E-glass fibers, a polypropylene matrix, and a coloring pigment: the GFRTPs with various fiber loadings (0, 10, and 20mass%) and pigmentations (0, 1, 2, and 4mass%) were fabricated by using an injection molding. The color differences of GFRTPs were measured based on the Commission Internationale de l'Eclairage (CIE) Lab color system, by comparing with a commercially available NMCD. The flexural properties of GFRTPs were evaluated by using a three-point bending test, according to International Standards Organization (ISO) specification number 20795-1. The visible colors of GFRTPs with pigment contents of 2mass% were acceptable for gingival color, and the glass fibers harmonized well with the resins. The ΔE* values of the GFRTPs with pigment contents of 2mass% obtained by using the CIE Lab system were lowest at all fiber loadings. For GFRTPs with fiber contents of 10 and 20mass% at 2mass% pigment content, these GFRTPs surpassed the ISO 20795-1 specification regarding flexural strength (> 60MPa) and modulus (> 1.5GPa). A combination of the results of color difference evaluation and mechanical examination indicates that the GFRTPs with fiber contents of 10 or 20mass%, and with pigment contents of 2mass% have acceptable esthetic appearance and sufficient rigidity for NMCDs. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yong Jun; Li, Chao; Zhou, When Jun
2018-06-01
This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.
NASA Astrophysics Data System (ADS)
Lee, Hyo Geun; Kim, Sang Suk; Kim, Sung Jo; Park, Su-Jin; Yun, Chang-wuk; Im, Gil-pyeong
2015-09-01
Photovoltaic generation systems have disadvantage in that they are usually installed outdoors and are exposed to extreme environments such as wind, snow and rain loadings. The structure of a photovoltaic generation system should be designed to have sufficient stiffness and strength against such loads. Especially, electric power generation by a concentrator photovoltaic(CPV) system can produce enough power if a right angle is main fained between the solar and the CPV panel within 90° ± 1°. To make the CPV tracking system in this study, we designed the structure by calculating the variations in and the strees applied to the structure by the wind load when the CPV tracking was influenced by the wind load. In this study, a 5-kW CPV tracking structure was designed through a structural analysis and a finiteelement analysis for a wind speed of 65 m/s by using ANSYS. The simulation of the structural design showed that the, structure of the 5-kW CPV tracking system corresponded with the ISO4017/ISO4762 standard. Based on this research, we will produce a 5-kW CPV tracking system and proceed to field test.
Effect of Roller Geometry on Roller Bearing Load-Life Relation
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.
2015-01-01
Cylindrical roller bearings typically employ roller profile modification to equalize load distribution, minimize stress concentration at roller ends and allow for a small amount of misalignment. The 1947 Lundberg-Palmgren analysis reported an inverse fourth power relation between load and life for roller bearings with line contact. In 1952, Lundberg and Palmgren changed their load-life exponent to 10/3 for roller bearings, assuming mixed line and point contact. The effect of roller-crown profile was reanalyzed in this paper to determine the actual load-life relation for modified roller profiles. For uncrowned rollers (line contact), the load-life exponent is p = 4, in agreement with the 1947 Lundberg-Palmgren value but crowning reduces the value of the exponent, p. The lives of modern roller bearings made from vacuum-processed steels significantly exceed those predicted by the Lundberg-Palmgren theory. The Zaretsky rolling-element bearing life model of 1996 produces a load-life exponent of p = 5 for flat rollers, which is more consistent with test data. For the Zaretsky model with fully crowned rollers p = 4.3. For an aerospace profile and chamfered rollers, p = 4.6. Using the 1952 Lundberg-Palmgren value p = 10/3, the value incorporated in ANSI/ABMA and ISO bearing standards, can create significant life calculation errors for roller bearings.
Integration of Behind-the-Meter PV Fleet Forecasts into Utility Grid System Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoff, Thomas Hoff; Kankiewicz, Adam
Four major research objectives were completed over the course of this study. Three of the objectives were to evaluate three, new, state-of-the-art solar irradiance forecasting models. The fourth objective was to improve the California Independent System Operator’s (ISO) load forecasts by integrating behind-the-meter (BTM) PV forecasts. The three, new, state-of-the-art solar irradiance forecasting models included: the infrared (IR) satellite-based cloud motion vector (CMV) model; the WRF-SolarCA model and variants; and the Optimized Deep Machine Learning (ODML)-training model. The first two forecasting models targeted known weaknesses in current operational solar forecasts. They were benchmarked against existing operational numerical weather prediction (NWP)more » forecasts, visible satellite CMV forecasts, and measured PV plant power production. IR CMV, WRF-SolarCA, and ODML-training forecasting models all improved the forecast to a significant degree. Improvements varied depending on time of day, cloudiness index, and geographic location. The fourth objective was to demonstrate that the California ISO’s load forecasts could be improved by integrating BTM PV forecasts. This objective represented the project’s most exciting and applicable gains. Operational BTM forecasts consisting of 200,000+ individual rooftop PV forecasts were delivered into the California ISO’s real-time automated load forecasting (ALFS) environment. They were then evaluated side-by-side with operational load forecasts with no BTM-treatment. Overall, ALFS-BTM day-ahead (DA) forecasts performed better than baseline ALFS forecasts when compared to actual load data. Specifically, ALFS-BTM DA forecasts were observed to have the largest reduction of error during the afternoon on cloudy days. Shorter term 30 minute-ahead ALFS-BTM forecasts were shown to have less error under all sky conditions, especially during the morning time periods when traditional load forecasts often experience their largest uncertainties. This work culminated in a GO decision being made by the California ISO to include zonal BTM forecasts into its operational load forecasting system. The California ISO’s Manager of Short Term Forecasting, Jim Blatchford, summarized the research performed in this project with the following quote: “The behind-the-meter (BTM) California ISO region forecasting research performed by Clean Power Research and sponsored by the Department of Energy’s SUNRISE program was an opportunity to verify value and demonstrate improved load forecast capability. In 2016, the California ISO will be incorporating the BTM forecast into the Hour Ahead and Day Ahead load models to look for improvements in the overall load forecast accuracy as BTM PV capacity continues to grow.”« less
An Investigation of Soft Proof to Print Agreement under Bright Surround
NASA Astrophysics Data System (ADS)
Zunjarrao, Vickrant J.
Color quality is a vital concern in the printing industry. The ability of an LCD monitor to accurately and consistently predict the color of a printed work is often in doubt. According to Chung (2005), color reproduction technology is different for soft proofing and hard proofing which could lead a layman to believe that the two technologies may not produce the same result. Nevertheless, it is still possible for both reproduction technologies to achieve a metameric match which gives the same perceived color sensation between display and print. ISO/CD 14681 provides guidelines for creating the conditions required to perform soft proofing. This standard builds on ISO 12646 requirements for monitors and introduces a new softproofing environment (lightbooth with integrated monitor) to better meet the needs of industrial users. The ISO 14681 integrated viewing environment removes one important obstacle to achieving print to softproof match, i.e., the problem of simultaneous color contrast inherent in using a dim monitor surround with a bright paper viewing condition for soft proofing. Thus, the first objective of this research was to assess print to softproof visual match in the ISO 14681 integrated viewing environment. Nevertheless, even in this environment, inconsistency between paper white and monitor white remains as the next major obstacle to achieving consistent print to softproof match. Thus, a second objective of this research is to develop a methodology for matching the monitor's white point to the white point of the paper viewed in an ISO 14681 integrated viewing environment. The methodology for fulfilling these objectives began with the creation of the hardware/software environment required to support experimentation. This environment consisted of a 24-inch EIZO CG242W display conforming to ISO 12646 and an integrated viewing environment conforming to the P2 specification in ISO 3664:2009. Two ISO 12647-2 conformed press sheets were prepared and became the reference for the experiment. The researcher next developed a methodology for matching the monitor white point to the white point of the paper under the P2 viewing condition. Finally, a panel of observers was used to compare print to softproof match for four display conditions in a paired comparison experiment. The results of the experiment were highly encouraging. The mismatch between monitor and paper white points, as measured by the sum of the differences in R, G, and B counts between the monitor and the paper, was reduced by nearly 90%. In addition, the paired comparison experiment demonstrated that the use of a custom monitor white point and optimized monitor gamma outperformed the use of standard D65 and D50 white points with the same optimized gamma at a .05 level of significance.
49 CFR 173.121 - Class 3-Assignment of packing group.
Code of Federal Regulations, 2011 CFR
2011-10-01
... packing group must be determined by applying the following criteria: Flash point (closed-cup) Initial... (73.4 °F) using the ISO standard cup with a 4 mm (0.16 inch) jet as set forth in ISO 2431 (IBR, see... using the ISO standard cup with a 6 mm (0.24 inch) jet. (ii) Solvent Separation Test. This test is...
Kettler, Annette; Bushelow, Michael; Wilke, Hans-Joachim
2012-06-01
Pre-clinical wear testing of intervertebral disc prostheses is commonly carried out according to ISO 18192-1. Ten million multiaxial loading cycles are applied at a frequency of 1 Hz. At this frequency, testing takes about 4 months. Testing at higher frequencies would therefore be desirable. ISO 18192-1 also offers testing at 2 Hz; however, it says the impact on the implant material behaviour as well as on the accuracy of the test machine shall be investigated by the user. Since such data are not available so far, the aim of this study was to carry out comparative wear tests at 1 and 2 Hz. Seven Prodisc-L lumbar disc prostheses were tested. After a pre-soak period, the implants were placed in specimen cups filled with calf serum, mounted to a Spine Wear Simulator and loaded according to ISO 18192-1. Testing was carried out at a temperature of 37 ± 2 °C. Four million loading cycles were applied at 1 Hz and eight million at 2 Hz in an alternating sequence. Each time after 12 days of testing the implants were removed to measure the weight and the height of the polyethylene cores. Then, the test serum was exchanged and the implants were remounted to the testing machine. The mean wear rate was 5.6 ± 2.3 mg per million cycles at 1 Hz and 7.7 ± 1.6 mg per million cycles at 2 Hz during the first six million loading cycles (p < 0.05) and 2.0 ± 0.6 and 4.1 ± 0.7 mg per million cycles during the second six million cycles (p < 0.05). Similarly, the mean heightloss was also smaller at 1 Hz than at 2 Hz (p < 0.05) with -0.02 ± 0.02 mm versus -0.04 ± 0.02 mm per million cycles during the first half of testing and -0.01 ± 0.01 versus -0.02 ± 0.01 mm per million cycles during the second half. The accuracy of the test machine was within the limits described by ISO 18192-1 at both frequencies. The results showed that the wear rate was higher at the beginning than at the end of testing. Also, the results indicated that testing at 2 Hz increases the wear rate compared with 1 Hz in case of a polyethylene-on-metal implant design. In the absence of retrieval studies it is difficult to decide which rate results in a more physiological wear pattern. However, a loading frequency of 1 Hz is probably closer to physiology than 2 Hz since the loading amplitudes prescribed by ISO 18192-1 are high. They rather represent movements like tying shoes or standing up from a chair than walking or sitting. The authors therefore suggest testing at 1 Hz.
Houlbert, C; Annaix, V; Szymanowicz, A; Vassault, A; Guimont, M C; Pernet, P
2012-02-01
In this paper, guidelines are proposed to fulfill the requirements of EN ISO 22870 standard regarding the management of point-of-care testing (POCT) nonconformities. In the first part, the main nonconformities that may affect POCT are given, the means for resolution and the control of adverse events are proposed. In the second part, we propose recommendations in case of unavailability of a point-of-care testing device from the occurring of the adverse event, to the restarting of the device.
Renal responses to plasma volume expansion and hyperosmolality in fasting seal pups
NASA Technical Reports Server (NTRS)
Ortiz, Rudy M.; Wade, Charles E.; Costa, Daniel P.; Ortiz, C. Leo
2002-01-01
Renal responses were quantified in northern elephant seal (Mirounga angustirostris) pups during their postweaning fast to examine their excretory capabilities. Pups were infused with either isotonic (0.9%; n = 8; Iso) or hypertonic (16.7%; n = 7; Hyper) saline via an indwelling catheter such that each pup received 3 mmol NaCl/kg. Diuresis after the infusions was similar in magnitude between the two treatments. Osmotic clearance increased by 37% in Iso and 252% in Hyper. Free water clearance was reduced 3.4-fold in Hyper but was not significantly altered in Iso. Glomerular filtration rate increased 71% in the 24-h period after Hyper, but no net change occurred during the same time after Iso. Natriuresis increased 3.6-fold in Iso and 5.3-fold in Hyper. Iso decreased plasma arginine vasopressin (AVP) and cortisol acutely, whereas Hyper increased plasma and excreted AVP and cortisol. Iso was accompanied by the retention of water and electrolytes, whereas the Hyper load was excreted within 24 h. Natriuresis is attributed to increased filtration and is independent of an increase in atrial natriuretic peptide and decreases in ANG II and aldosterone. Fasting pups appear to have well-developed kidneys capable of both extreme conservation and excretion of Na(+).
In-vitro analysis of the microbicidal activity of 6 contact lens care solutions
2012-01-01
Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001). The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical disinfectants and antiseptics, which consists of three test phases and also requests meeting stricter criteria in order to pass the test. Unless the test conditions guarantee a sufficient reduction of potential pathogens, the risk of contact lens-related microbial keratitis and other infections will remain for the users. PMID:23033880
Does the chromatic Mach bands effect exist?
Tsofe, Avital; Spitzer, Hedva; Einav, Shmuel
2009-06-30
The achromatic Mach bands effect is a well-known visual illusion, discovered over a hundred years ago. This effect has been investigated thoroughly, mainly for its brightness aspect. The existence of Chromatic Mach bands, however, has been disputed. In recent years it has been reported that Chromatic Mach bands are not perceived under controlled iso-luminance conditions. However, here we show that a variety of Chromatic Mach bands, consisting of chromatic and achromatic regions, separated by a saturation ramp, can be clearly perceived under iso-luminance and iso-brightness conditions. In this study, observers' eye movements were recorded under iso-brightness conditions. Several observers were tested for their ability to perceive the Chromatic Mach bands effect and its magnitude, across different cardinal and non-cardinal Chromatic Mach bands stimuli. A computational model of color adaptation, which predicted color induction and color constancy, successfully predicts this variation of Chromatic Mach bands. This has been tested by measuring the distance of the data points from the "achromatic point" and by calculating the shift of the data points from predicted complementary lines. The results suggest that the Chromatic Mach bands effect is a specific chromatic induction effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, Lisa; Kalume, Aimable; Wagner, James
Iso-polyhalomethanes are known reactive intermediates that play a pivotal role in the photochemistry of halomethanes in condensed phases. In this work, iso-bromoform (iso-CHBr{sub 3}) and its deuterated isotopomer were characterized by matrix isolation infrared and UV/visible spectroscopy, supported by ab initio and density functional theory calculations, to further probe the structure, spectroscopy, and photochemistry of this important intermediate. Selected wavelength laser irradiation of CHBr{sub 3} isolated in Ar or Ne matrices at {approx}5 K yielded iso-CHBr{sub 3}; the observed infrared and UV/visible absorptions are in excellent agreement with computational predictions, and the energies of various stationary points on the CHBr{submore » 3} potential energy surface were characterized computationally using high-level methods in combination with correlation consistent basis sets. These calculations show that, while the corresponding minima lie {approx}200 kJ/mol above the global CHBr{sub 3} minimum, the isomer is bound by some 60 kJ/mol in the gas phase with respect to the CHBr{sub 2}+ Br asymptote. The photochemistry of iso-CHBr{sub 3} was investigated by selected wavelength laser irradiation into the intense S{sub 0}{yields} S{sub 3} transition, which resulted in back photoisomerization to CHBr{sub 3}. Intrinsic reaction coordinate calculations confirmed the existence of a first-order saddle point connecting the two isomers, which lies energetically below the threshold of the radical channel. Subsequently, natural bond orbital analysis and natural resonance theory were used to characterize the important resonance structures of the isomer and related stationary points, which demonstrate that the isomerization transition state represents a crossover from dominantly covalent to dominantly ionic bonding. In condensed phases, the ion-pair dominated isomerization transition state structure is preferentially stabilized, so that the barrier to isomerization is lowered.« less
Basílio, Mariana de Almeida; Delben, Juliana Aparecida; Cesar, Paulo Francisco; Rizkalla, Amin Sami; Santos Junior, Gildo Coelho; Arioli Filho, João Neudenir
2016-07-01
Yttria-stabilized tetragonal zirconia (Y-TZP) was introduced as ceramic implant abutments due to its excellent mechanical properties. However, the damage patterns for Y-TZP abutments are limited in the literature. Fractographic analyses can provide insights as to the failure origin and related mechanisms. The purpose of this study was to analyze fractured Y-TZP abutments to establish fractographic patterns and then possible reasons for failure. Thirty two prefabricated Y-TZP abutments on external hex implants were retrieved from a single-load-to failure test according to the ISO 14801. Fractographic analyses were conducted under polarized-light estereo and scanning electro microscopy. The predominant fracture pattern was abutment fracture at the connecting region. Classic fractographic features such as arrest lines, hackle, and twist hackle established that failure started where Y-TZP abutments were in contact with the retention screw edges. The abutment screw design and the loading point were the reasons for localized stress concentration and fracture patterns. Copyright © 2016 Elsevier Ltd. All rights reserved.
Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat
2017-05-01
The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
The ISOPHOT far-infrared serendipity north ecliptic pole minisurvey
NASA Astrophysics Data System (ADS)
Stickel, M.; Bogun, S.; Lemke, D.; Klaas, U.; Toth, L. V.; Herbstmeier, U.; Richter, G.; Assendorp, R.; Laureijs, R.; Kessler, M. F.; Burgdorf, M.; Beichman, C. A.; Rowan-Robinson, M.; Efstathiou, A.
1998-08-01
The ISOPHOT Serendipity Survey fills the otherwise unused slew time between ISO's fine pointings with measurements in an unexplored wavelength regime near 200 microns. In order to test point source extraction software, the completeness of the detected objects as well as the astrophysical content we investigate a 100 sq degr field near the North ecliptic pole, dubbed ISOPHOT Serendipity Minisurvey field. A total of 21 IRAS point sources were detected on the Serendipity slews crossing the field. 19 of these objects are galaxies, one is a planetary nebula and one is an empty field without a bright optical counterpart. The detection completeness is better than 90% for IRAS sources brighter than 2 Jy at 100 microns and better than 80% for sources brighter than 1.5 Jy. The source detection frequency is about 1 per 40degr slew length, in agreement with previous estimations based on galaxy number counts. After the end of the ISO mission, about 4000 point sources are expected to be found in the Serendipity slews. Based on observations with ISO, an ESA project with instruments funded by ESA Member States (especially the PI countries: France, Germany, the Netherlands and the United Kingdom) and with the participation of ISAS and NASA. Members of the Consortium on the ISOPHOT Serendipity Survey (CISS) are MPIA Heidelberg, ESA ISO SOC Villafranca, AIP Potsdam, IPAC Pasadena, Imperial College London
Hard-on-hard lubrication in the artificial hip under dynamic loading conditions.
Sonntag, Robert; Reinders, Jörn; Rieger, Johannes S; Heitzmann, Daniel W W; Kretzer, J Philippe
2013-01-01
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal.
Hard-on-Hard Lubrication in the Artificial Hip under Dynamic Loading Conditions
Sonntag, Robert; Reinders, Jörn; Rieger, Johannes S.; Heitzmann, Daniel W. W.; Kretzer, J. Philippe
2013-01-01
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short- and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e.g., using metal-on-metal. PMID:23940772
Ashley, Madeleine; Dixon, Mike; Sisodiya, Ajit; Prasad, Krishna
2012-08-01
Menthol can reduce sensory irritation and it has been hypothesised that this could result in smokers of mentholated cigarettes taking larger puffs and deeper post-puff inhalations thereby obtaining higher exposures to smoke constituents than smokers of non-mentholated cigarettes. The aim of our study was to use part-filter analysis methodology to assess the effects of cigarette menthol loading on regular and occasional smokers of mentholated cigarettes. We measured mouth level exposure to tar and nicotine and investigated the effects of mentholation on smokers' sensory perceptions such as cooling and irritation. Test cigarettes were produced containing no menthol and different loadings of synthetic and natural l-menthol at 1 and 4mg ISO tar yields. A target of 100 smokers of menthol cigarettes and 100 smokers who predominantly smoked non-menthol cigarettes from both 1 and 4mg ISO tar yield categories were recruited in Poland and Japan. Each subject was required to smoke the test cigarette types of their usual ISO tar yield. There were positive relationships between menthol loading and the perceived 'strength of menthol taste' and 'cooling' effect. However, we did not see marked menthol-induced reductions in perceived irritation or menthol-induced increases in mouth level exposure to tar and nicotine. Copyright © 2012 Elsevier Inc. All rights reserved.
Assessing the Value of Regulation Resources Based on Their Time Response Characteristics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, Yuri V.; Lu, Shuai; Ma, Jian
2008-06-01
Fast responsive regulation resources are potentially more valuable as a power system regulation resource (more efficient) because they allow applying controls at the exact moment and in the exact amount as needed. Faster control is desirable because it facilitates more reliable compliance with the NERC Control Performance Standards at relatively lesser regulation capacity procurements. The current California ISO practices and markets do not provide a differentiation among the regulation resources based on their speed of response (with the exception of some minimum ramping capabilities). Some demand response technologies, including some generation and energy storage resources, can provide quicker control actions.more » California ISO practices and markets could be updated to welcome more fast regulation resources into the California ISO service area. The project work reported in this work was pursuing the following objectives: • Develop methodology to assess the relative value of generation resources used for regulation and load following California ISO functions • This assessment should be done based on physical characteristics including the ability to quickly change their output following California ISO signals • Evaluate what power is worth on different time scales • Analyze the benefits of new regulation resources to provide effective compliance with the mandatory NERC Control Performance Standards • Evaluate impacts of the newly proposed BAAL and FRR standards on the potential value of fast regulation and distributed regulation resources • Develop a scope for the follow-up projects to pave a road for the new efficient types of balancing resources in California. The work included the following studies: • Analysis of California ISO regulating units characteristics • California ISO automatic generation system (AGC) analysis • California ISO regulation procurement and market analysis • Fast regulation efficiency analysis • Projection of the California ISO load following and regulation requirements into the future • Value of fast responsive resources depending on their ramping capability • Potential impacts of the balancing authority area control error limit (BAAL), which is a part of the newly proposed NERC standard “Balancing Resources and Demand” • Potential impacts of the Western Electricity Coordinating Council (WECC) frequency responsive reserve (FRR) standard • Recommendations for the next phase of the project. The following main conclusions and suggestions for the future have been made: • The analysis of regulation ramping requirements shows that the regulation system should be able to provide ramps of at least 40-60 MW per minute for a period up to 6 minutes. • Evaluate if changes are needed in the California ISO AGC system to effectively accommodate new types of fast regulation resources and minimize the California ISO regulation procurement. • California ISO may consider creating better market opportunities for and incentives for fast responsive resources. • An additional study of low probability high ramp events can be recommended to the California ISO. • The California ISO may be willing to consider establishing a more relaxed target CPS2 compliance level. • A BAAL-related study can be recommended for the California ISO as soon as more clarity is achieved concerning the actual enforcement of the BAAL standard and its numerical values for the California ISO. The study may involve an assessment of advantages of the distributed frequency-based control for the California ISO system. The market-related issues that arise in this connection can be also investigated. • A FRR-related study can be recommended for the California ISO as soon as more clarity is achieved concerning the actual enforcement of the FRR standard and its numerical values for the California ISO.« less
IAL SPACE: A test laboratory for the ISO cryogenic payload
NASA Technical Reports Server (NTRS)
Cucchiaro, A.; Henrist, M.; Macau, J. P.; Ninane, N.; Blanpain, R.
1990-01-01
The ESA Infrared Space Observatory (ISO) satellite is a 3 axes pointed platform designed to make accurate pointed observations of astronomical objects and sources in the wavelength range between 2.5 and 200 microns. ISO is composed of a service module and a payload module which is a large cylindrical vacuum vessel. The vessel is in fact a cryostat (capacity of 2250 l of liquid He II) which contains the telescope and the four focal scientific instruments. The latter being cooled up to a temperature less than 4 K. The qualification of the payload requires the measurement respectively of: the image quality of the telescope through wave front error (WFE) measurements; and the optical alignment of the scientific instruments with respect to the telescope axis and the telescope focus, and this under cryogenic conditions. Consequently, since 1988, the FOCAL 5 IAL Space facility has been upgraded in order to perform the cryogenic optical tests of the ISO optical subsystems.
Melli, Virginia; Juszczyk, Mateusz; Sandrini, Enrico; Bolelli, Giovanni; Bonferroni, Benedetta; Lusvarghi, Luca; Cigada, Alberto; Manfredini, Tiziano; De Nardo, Luigi
2015-01-01
The increasing number of total joint replacements, in particular for the knee joint, has a growing impact on the healthcare system costs. New cost-saving manufacturing technologies are being explored nowadays. Metal injection molding (MIM) has already demonstrated its suitability for the production of CoCrMo alloy tibial trays, with a significant reduction in production costs, by holding both corrosion resistance and biocompatibility. In this work, mechanical and tribological properties were evaluated on tibial trays obtained via MIM and conventional investment casting. Surface hardness and wear properties were evaluated through Vickers hardness, scratch and pin on disk tests. The MIM and cast finished tibial trays were then subjected to a fatigue test campaign in order to obtain their fatigue load limit at 5 millions cycles following ISO 14879-1 directions. CoCrMo cast alloy exhibited 514 HV hardness compared to 335 HV of MIM alloy, furthermore it developed narrower scratches with a higher tendency towards microploughing than microcutting, in comparison to MIM CoCrMo. The observed fatigue limits were (1,766 ± 52) N for cast tibial trays and (1,625 ± 44) N for MIM ones. Fracture morphologies pointed out to a more brittle behavior of MIM microstructure. These aspects were attributed to the absence of a fine toughening and surface hardening carbide dispersion in MIM grains. Nevertheless, MIM tibial trays exhibited a fatigue limit far beyond the 900 N of maximum load prescribed by ISO and ASTM standards for the clinical application of these devices.
La Barbera, Luigi; Ottardi, Claudia; Villa, Tomaso
2015-10-01
Preclinical evaluation of the mechanical reliability of fixation devices is a mandatory activity before their introduction into market. There are two standardized protocols for preclinical testing of spinal implants. The American Society for Testing Materials (ASTM) recommends the F1717 standard, which describes a vertebrectomy condition that is relatively simple to implement, whereas the International Organization for Standardization (ISO) suggests the 12189 standard, which describes a more complex physiological anterior support-based setup. Moreover, ASTM F1717 is nowadays well established, whereas ISO 12189 has received little attention: A few studies tried to accurately describe the ISO experimental procedure through numeric models, but these studies totally neglect the recommended precompression step. This study aimed to build up a reliable, validated numeric model capable of describing the stress on the rods of a spinal fixator assembled according to ISO 12189 standard procedure. Such a model would more adequately represent the in vitro testing condition. This study used finite element (FE) simulations and experimental validation testing. An FE model of the ISO setup was built to calculate the stress on the rods. Simulation was validated by comparison with experimental strain gauges measurements. The same fixator has been previously virtually mounted in an L2-L4 FE model of the lumbar spine, and stresses in the rods were calculated when the spine was subjected to physiological forces and moments. The comparison between the FE predictions and experimental measurements is in good agreement, thus confirming the suitability of the FE method to evaluate the stresses in the device. The initial precompression induces a significant extension of the assembled construct. As the applied load increases, the initial extension is gradually compensated, so that at peak load the rods are bent in flexion: The final stress value predicted is thus reduced to about 50%, if compared with the previous model where the precompression was not considered. Neglecting the initial preload due to the assembly of the overall construct according to ISO 12189 standard could lead to an overestimation of the stress on the rods up to 50%. To correctly describe the state of stress on the posterior spinal fixator, tested according to the ISO procedure, it is important to take into account the initial preload due to the assembly of the overall construct. Copyright © 2015 Elsevier Inc. All rights reserved.
Garoushi, Sufyan K; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2006-09-01
The aim of this study was to determine the static load-bearing capacity of composite resin onlay restorations made of particulate filler composite (PFC) with two different types of fiber-reinforced composite (FRC) substructures. In addition, flexural properties of the material combination and the effect of polymerization devices were tested. Specimens were prepared to simulate an onlay restoration, which consisted of 2 to 3 mm of FRC layer as a substructure (short random and continuous bidirectional fiber orientation) and a 1 mm surface layer of PFC. Control specimens were prepared from plain PFC. In Group A the specimens were incrementally polymerized only with a hand-light curing unit for 40 s, while in Group B the specimens were post-cured in a light-curing oven for 15 min before they were statically loaded with a steel ball. Bar-shaped test specimens were prepared to measure the flexural properties of material combination using a three-point bending test (ISO 10477). Analysis of variance (ANOVA) revealed all specimens with a FRC substructure have higher values of static load-bearing capacity and flexural properties than those obtained with plain PFC (p<0.001). The load-bearing capacity of all the specimens decreased after post-curing and water storage. Restorations made from a material combination of FRC and PFC showed better mechanical properties than those obtained with plain PFC.
49 CFR 173.121 - Class 3-Assignment of packing group.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-cup) Initial boiling point I ≤35°C (95 °F) II 35 °C (95 °F) III ≥23 °C, ≤60 °C (≥73 °F, ≤140 °F) >35... determined at 23 °C (73.4 °F) using the ISO standard cup with a 4 mm (0.16 inch) jet as set forth in ISO 2431... carried out using the ISO standard cup with a 6 mm (0.24 inch) jet. (ii) Solvent Separation Test. This...
Influence of a peracetic acid-based immersion on indirect composite resin.
Samuel, Susana Maria Werner; Fracaro, Gisele Baggio; Collares, Fabrício Mezzomo; Leitune, Vicente Castelo Branco; Campregher, Ulisses Bastos
2011-06-01
The aim of this study was to evaluate the influence of immersion in a 0.2% peracetic acid-based disinfectant on the three-point flexural strength, water sorption and water solubility of an indirect composite resin. Specimens were produced according to ISO 4049:2000 specifications and were divided in two groups: Control group, with no disinfection and Disinfected group, with three 10 min immersions in the peracetic acid intercalated with 10 min immersions in sterile distilled water. All evaluations were conducted in compliance with ISO specifications. Three-point flexural strength, water sorption and solubility of indirect composite resin before and after immersion showed no statistical significant differences (p > 0.05) and met ISO standard requirements. Immersion in peracetic acid solution showed no influence in indirect composite resin tested properties.
Abbas, Samah S; Zaazaa, Hala E; Abdelkawy, M; Abdelrahman, Maha M
2010-04-01
Four sensitive, selective and precise stability indicating methods for the determination of isopropamide iodide (ISO) and trifluoperazine hydrochloride (TPZ) in their binary mixture and in presence of trifluoperazine oxidative degradate (OXD). Method A is a derivative spectrophotometric one, where ISO was determined by first derivative (D(1)) at 226.4 nm while TPZ was determined by second derivative (D(2)) at 270.2 nm. Method B is the first derivative of the ratio spectra (DD(1)) spectrophotometric method, ISO can be determined by measuring the peak amplitude at 227.4 nm using 5 microg mL(-1) of OXD as a divisor, while TPZ can be determined by measuring the peak amplitude at 249.2 and 261.4 nm using 15 microg mL(-1) of ISO as a divisor. Method C is the isoabsorptive spectrophotometric method. This method allows determination of ISO and TPZ in their binary mixture by measuring total concentration of ISO and TPZ at their isoabsorptive point at lambda(229.8) nm (Aiso1) while TPZ concentration alone can be determined at lambda(max) 311.2 nm, then ISO concentration can be determined by subtraction. On the same basis TPZ can be determined in presence of ISO and OXD, where OXD concentration alone was determined by measuring the peak amplitude at lambda(281.6) and lambda(309.4) nm while total concentration of TPZ and OXD was determined at their isoabsorptive points at (Aiso2 = 270.2 nm), (Aiso3 = 310.6 nm) and (Aiso4 = 331.8 nm) then TPZ concentration was determined by subtraction. Method D is the multivariate calibration techniques [the classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS)], using the information contained in the absorption spectra of ISO, TPZ and OXD mixtures. The selectivity of the proposed methods was checked using laboratory prepared mixtures. The proposed methods have been successfully applied to the analysis of ISO and TPZ in pharmaceutical dosage form without interference from other dosage form additives and the results were statistically compared with the reported method.
Isocyanate Cross-Linked Silica: Structurally Strong Aerogels
NASA Technical Reports Server (NTRS)
Leventis, Nicholas; Sotiriou-Leventis, Chariklia; Zhang, Guo-Hui; Rawashdeh, Abdel-Monem M.
2002-01-01
Molecular-level synergism between the silica nanoparticles of pre-formed monoliths and molecular cross-linkers inverts the relative host-guest roles in glass-polymer composites, leading to new strong low-density materials. Attempts to load gels with variable amounts of polyurethane precursors such as di-ISO and diol end-capped polybutylene adipate followed by heat treatment, washing, and supercritical drying led to opaque materials, somewhat stronger than silica but still quite brittle and much inferior to the materials described above. Direct mixing of a diisocyanate and an alcohol-free sol has been attempted recently by Yim et al. Reportedly, that procedure leads to week-long gelation times and requires an at least equally long aging period. In our attempt to add various amounts of di-ISO in a base-catalyzed sol in PC, we also noticed a week-long gelation time. The resulting aerogels were translucent but no less brittle than native silica. According to more recent studies, if propylene carbonate is replaced with acetone, it leads not only to shorter processing times, but also to much stronger gels that can tolerate loads in excess of 40 kg in the arrangement presented. We attribute that behavior to the lower viscosity of acetone, that allows faster diffusion of the di-ISO solution within the pores before di-ISO has time to react with the surface of silica. Further studies are underway to vary the chemical identity of the diisocyanate, as well as the composition and density of silica.
IsoSCM: improved and alternative 3′ UTR annotation using multiple change-point inference
Shenker, Sol; Miura, Pedro; Sanfilippo, Piero
2015-01-01
Major applications of RNA-seq data include studies of how the transcriptome is modulated at the levels of gene expression and RNA processing, and how these events are related to cellular identity, environmental condition, and/or disease status. While many excellent tools have been developed to analyze RNA-seq data, these generally have limited efficacy for annotating 3′ UTRs. Existing assembly strategies often fragment long 3′ UTRs, and importantly, none of the algorithms in popular use can apportion data into tandem 3′ UTR isoforms, which are frequently generated by alternative cleavage and polyadenylation (APA). Consequently, it is often not possible to identify patterns of differential APA using existing assembly tools. To address these limitations, we present a new method for transcript assembly, Isoform Structural Change Model (IsoSCM) that incorporates change-point analysis to improve the 3′ UTR annotation process. Through evaluation on simulated and genuine data sets, we demonstrate that IsoSCM annotates 3′ termini with higher sensitivity and specificity than can be achieved with existing methods. We highlight the utility of IsoSCM by demonstrating its ability to recover known patterns of tissue-regulated APA. IsoSCM will facilitate future efforts for 3′ UTR annotation and genome-wide studies of the breadth, regulation, and roles of APA leveraging RNA-seq data. The IsoSCM software and source code are available from our website https://github.com/shenkers/isoscm. PMID:25406361
[ISO 9002 at the Center of Pediatric Intensive Care at the Albert Einstein Israeli Hospital].
Gé Lacerda, D P; Rocha, M L; Santos, R P
2000-01-01
This study shows the process of implementation of a quality program in Pediatric Intensive Therapy Center of "Hospital Israelita Albert Einstein" which resulted in the certification of this service for the Standards ISO 9002/94. It points out the nurse's role as a leader in this process.
Adsorption and separation of n/iso-pentane on zeolites: A GCMC study.
Fu, Hui; Qin, Hansong; Wang, Yajun; Liu, Yibin; Yang, Chaohe; Shan, Honghong
2018-03-01
Separation of branched chain hydrocarbons and straight chain hydrocarbons is very important in the isomerization process. Grand canonical ensemble Monte Carlo simulations were used to investigate the adsorption and separation of iso-pentane and n-pentane in four types of zeolites: MWW, BOG, MFI, and LTA. The computation of the pure components indicates that the adsorption capacity is affected by physical properties of zeolite, like pore size and structures, and isosteric heat. In BOG, MFI and LTA, the amount of adsorption of n-pentane is higher than iso-pentane, while the phenomenon is contrary in MWW. For a given zeolite, a stronger adsorption heat corresponds to a higher loading. In the binary mixture simulations, the separation capacity of n-and iso-pentane increases with the elevated pressure and the increasing iso-pentane composition. The adsorption mechanism and competition process have been examined. Preferential adsorption contributions prevail at low pressure, however, the size effect becomes important with the increasing pressure, and the relatively smaller n-pentane gradually competes successfully in binary adsorption. Among these zeolites, MFI has the best separation performance due to its high shape selectivity. This work helps to better understand the adsorption and separation performance of n- and iso-pentane in different zeolites and explain the relationship between zeolite structures and adsorption performance. Copyright © 2017 Elsevier Inc. All rights reserved.
Milazzo, Maria Francesca; Ancione, Giuseppa; Lisi, Roberto
2017-12-15
Emissions due to ship-loading of hydrocarbons are currently not addressed neither by the Directive on the integrated pollution prevention or by other environmental regulations. The scope of this study is to point towards the environmental and safety concerns associated with such emissions, even if proper attention has not been given to this issue until now. In order to achieve this goal, the modelling of the emission volatile organic compounds (VOC), due to ship-load operations at refineries has been made by means of the definition of a simulation procedure which includes a proper treatment of the hours of calm. Afterwards, a quantitative analysis of VOC dispersion for an Italian case-study is presented with the primary aims: (i) to develop and verify the validity of the approach for the modelling of the emission sources and of the diffusion of these contaminants into the atmosphere by a proper treatment of the hours of calm and (ii) to identify their contribution to the total VOC emitted in a typical refinery. The calculated iso-concentration contours have also been drawn on a map and allowed the identification of critical areas for people protecting by the adoption of abatement solutions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.
Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei
2012-06-01
The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.
Wang, Dai-Jun; Tian, Hua
2014-12-01
To date, there are no effective treatments for extremity ischemia-reperfusion (IR) injury. The objective of the present study was to explore the protective effect of Mailuoning on IR injury by investigating the plasma levels of 8-iso-prostaglandin F2 alpha (8-iso-PGF2α) and the activity of superoxide dismutase (SOD) in rabbits. The experimental models of posterior limb IR injury were established in thirty rabbits that were divided into three groups: the sham, IR, and IR + Mailuoning groups. At the end of ischemia, Mailuoning was injected intravenously into the rabbits in the IR + Mailuoning group, and normal saline solution was administered to the rabbits in the sham and IR groups. Venous blood samples were collected to measure the levels of 8-iso-PGF2α and the activity of SOD in the plasma at the following time points: at the onset of ischemia, the end of ischemia, and 2, 4, 8, 12, and 24 h after reperfusion. The skeletal muscles were harvested to examine the ultrastructure. The levels of 8-iso-PGF2α increased significantly and SOD activity decreased in the IR group at every time point after reperfusion (P <0.01 or P <0.05). In contrast, the levels of 8-iso-PGF2α and SOD activity were not significantly different after reperfusion in the IR + Mailuoning group (P >0.05) but were significantly different compared with the IR group (P <0.01). Using electron microscopy, the skeletal muscle injury was shown to be milder in the IR+ Mailuoning group after reperfusion compared with the IR group. The Mailuoning is capable of decreasing the excessive production of 8-iso-PGF2α and protecting SOD activity, thereby exhibiting a protective effect on extremity IR injury. Copyright © 2014 Elsevier Inc. All rights reserved.
An Observational Upper Limit on the Interstellar Number Density of Asteroids and Comets
NASA Astrophysics Data System (ADS)
Engelhardt, Toni; Jedicke, Robert; Vereš, Peter; Fitzsimmons, Alan; Denneau, Larry; Beshore, Ed; Meinke, Bonnie
2017-03-01
We derived 90% confidence limits (CLs) on the interstellar number density ({ρ }{IS}{CL}) of interstellar objects (ISOs; comets and asteroids) as a function of the slope of their size-frequency distribution (SFD) and limiting absolute magnitude. To account for gravitational focusing, we first generated a quasi-realistic ISO population to ˜ 750 {au} from the Sun and propagated it forward in time to generate a steady state population of ISOs with heliocentric distance < 50 {au}. We then simulated the detection of the synthetic ISOs using pointing data for each image and average detection efficiencies for each of three contemporary solar system surveys—Pan-STARRS1, the Mt. Lemmon Survey, and the Catalina Sky Survey. These simulations allowed us to determine the surveys’ combined ISO detection efficiency under several different but realistic modes of identifying ISOs in the survey data. Some of the synthetic detected ISOs had eccentricities as small as 1.01, which is in the range of the largest eccentricities of several known comets. Our best CL of {ρ }{IS}{CL}=1.4× {10}-4 {{au}}-3 implies that the expectation that extra-solar systems form like our solar system, eject planetesimals in the same way, and then distribute them throughout the Galaxy, is too simplistic, or that the SFD or behavior of ISOs as they pass through our solar system is far from expectation.
Gaudez, Clarisse; Cail, François
2016-11-01
This study compared muscular and postural stresses, performance and subject preference in women aged 18-40 years using a standard mouse, a vertical mouse and a slanted mouse in three different computer workstation positions. Four tasks were analysed: pointing, pointing-clicking, pointing-clicking-dragging and grasping-pointing the mouse after typing. Flexor digitorum superficialis (FDS) and extensor carpi radialis (ECR) activities were greater using the standard mouse compared to the vertical or slanted mouse. In all cases, the wrist position remained in the comfort zone recommended by standard ISO 11228-3. The vertical mouse was less comfortable and more difficult to use than the other two mice. FDS and ECR activities, shoulder abduction and wrist extension were greater when the mouse was placed next to the keyboard. Performance and subject preference were better with the unrestricted mouse positioning on the desktop. Grasping the mouse after typing was the task that caused the greatest stress. Practitioner Summary: In women, the slanted mouse and the unrestricted mouse positioning on the desktop provide a good blend of stresses, performance and preference. Unrestricted mouse positioning requires no keyboard, which is rare in practice. Placing the mouse in front of the keyboard, rather than next to it, reduced the physical load.
Latash, Mark L
2018-02-21
The main goal of this paper is to introduce the concept of iso-perceptual manifold for perception of body configuration and related variables (kinesthetic perception) and to discuss its relation to the equilibrium-point hypothesis and the concepts of reference coordinate and uncontrolled manifold. Hierarchical control of action is postulated with abundant transformations between sets of spatial reference coordinates for salient effectors at different levels. Iso-perceptual manifold is defined in the combined space of afferent and efferent variables as the subspace corresponding to a stable percept. Examples of motion along an iso-perceptual manifold (perceptually equivalent motion) are considered during various natural actions. Some combinations of afferent and efferent signals, in particular those implying a violation of body's integrity, give rise to variable percepts by artificial projection onto iso-perceptual manifolds. This framework is used to interpret unusual features of vibration-induced kinesthetic illusions and to predict new illusions not yet reported in the literature. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.
Supersymmetric Janus solutions of dyonic ISO(7)-gauged N = 8 supergravity
NASA Astrophysics Data System (ADS)
Suh, Minwoo
2018-04-01
We study supersymmetric Janus solutions of dyonic ISO(7)-gauged N = 8 supergravity. We mostly find Janus solutions flowing to 3d N = 8 SYM phase which is the worldvolume theory on D2-branes and non-conformal. There are also solutions flowing from the critical points which are dual to 3d SCFTs from deformations of the D2-brane theory.
Akyar, Işin
2009-10-01
One important trend in the laboratory profession and quality management is the global convergence of laboratory operations. The goal of an accredited medical laboratory is to continue "offering useful laboratory service for diagnosis and treatment of the patients and also aid to the health of the nation". An accredited clinical laboratory is managed by a quality control system, it is competent technically and the laboratory service meets the needs of all its patients and physicians by taking the responsibility of all the medical tests and therapies. For this purpose, ISO 15189 international standard has been prepared by 2003. ISO 15189 standard is originated from the arrangement of ISO 17025 and ISO 9001:2000 standards. Many countries such as England, Germany, France, Canada and Australia have preferred ISO 15189 as their own laboratory accreditation programme, meeting all the requirements of their medical laboratories. The accreditation performance of a clinical microbiology laboratory is mainly based on five essential points; preanalytical, analytical, postanalytical, quality control programmes (internal, external, interlaboratory) and audits (internal, external). In this review article, general concepts on ISO 15189 accreditation standards for the clinical microbiology laboratories have been summarized and the status of a private laboratory (Acibadem LabMed, Istanbul) in Turkey has been discussed.
Kelly, J Robert; Rungruanganunt, Patchnee
2016-01-01
Zirconia is being widely used, at times apparently by simply copying a metal design into ceramic. Structurally, ceramics are sensitive to both design and processing (fabrication) details. The aim of this work was to examine four computer-aided design/computer-assisted manufacture (CAD/CAM) abutments using a modified International Standards Organization (ISO) implant fatigue protocol to determine performance as a function of design and processing. Two full zirconia and two hybrid (Ti-based) abutments (n = 12 each) were tested wet at 15 Hz at a variety of loads to failure. Failure probability distributions were examined at each load, and when found to be the same, data from all loads were combined for lifetime analysis from accelerated to clinical conditions. Two distinctly different failure modes were found for both full zirconia and Ti-based abutments. One of these for zirconia has been reported clinically in the literature, and one for the Ti-based abutments has been reported anecdotally. The ISO protocol modification in this study forced failures in the abutments; no implant bodies failed. Extrapolated cycles for 10% failure at 70 N were: full zirconia, Atlantis 2 × 10(7) and Straumann 3 × 10(7); and Ti-based, Glidewell 1 × 10(6) and Nobel 1 × 10(21). Under accelerated conditions (200 N), performance differed significantly: Straumann clearly outperformed Astra (t test, P = .013), and the Glidewell Ti-base abutment also outperformed Atlantis zirconia at 200 N (Nobel ran-out; t test, P = .035). The modified ISO protocol in this study produced failures that were seen clinically. The manufacture matters; differences in design and fabrication that influence performance cannot be discerned clinically.
The effect of N-acetylcysteine on mechanical fatigue resistance of antibiotic-loaded bone cement.
Sukur, Erhan; Akar, Abdulhalim; Topcu, Huseyin Nevzat; Cicekli, Ozgur; Kochai, Alauddin; Turker, Mehmet
2018-05-31
This biomechanical study evaluates the effect of N-acetylcysteine alone and in combination with the most commonly used antibiotic-loaded bone cement mixtures. We mixed eight bone cement mixture groups including combinations of N-acetylcysteine, gentamicin, teicoplanin, and vancomycin and applied a four-point bending test individually to each sample on days 1 and 15 using an MTS Acumen test device. The result was less than 50 MPa-the limit declared by the ISO (International Standards Organization)-in only the "gentamicin + bone cement + N-acetylcysteine" group. Mechanical fatigue resistance of the bone cement decreased significantly with the addition of N-acetylcysteine both on day 1 and day 15 (p < 0.001). With the addition of N-acetylcysteine into the "gentamicin + bone cement" and "vancomycin + bone cement" mixtures, a significant decrease in mechanical fatigue resistance was observed both on day 1 and day 15 (p < 0.001). In contrast, with the addition of N-acetylcysteine into the "teicoplanin + bone cement" mixture, no significant difference in mechanical fatigue resistance was observed on days 1 and 15 (p = 0.093, p = 0.356). Preliminary results indicate that adding N-acetylcysteine to teicoplanin-loaded bone cement does not significantly affect the cement's mechanical resistance, potentially leading to a new avenue for preventing and treating peri-prosthetic joint infection. N-acetylcysteine may, therefore, be considered as an alternative agent to be added to antibiotic-loaded bone cement mixtures used in the prevention of peri-prosthetic joint infection.
Kaludjerovic, Jovana; Ward, Wendy E
2015-10-01
Female mice exposed to soy isoflavones (ISO) during early postnatal life have improved bone outcomes at adulthood. Since long-lasting effects may be mediated by DNA methylation, we hypothesized that providing supplemental folic acid (FA), a methyl donor, during early life, would enhance the positive effect of ISO to bone health. Bone-specific gene expression patterns were studied to understand potential mechanisms. CD-1 dams (n=36) were randomized to adequate or supplemental levels of FA (2 or 8 mg/kg diet) during pregnancy and lactation, and offspring received corn oil or ISO (7 mg/kg body weight/d) from postnatal day 1 to 10. From weaning, pups were fed an adequate FA diet and were studied to 4 months of age. Female offspring exposed to supplemental FA+ISO had higher bone mineral density (BMD), trabecular connectivity and peak load at the lumbar spine compared to females exposed to adequate FA. Female offspring exposed to adequate FA+ISO or supplemental FA had higher (P<.05) BMD and greater resistance to fracture at the lumbar spine and the femur; higher trabecular connectivity at the lumbar spine; and lower expression of DNA methyltransferase 3a (Dnmt3a) and neuropeptide Y (NPY) in the femur compared to mice exposed to adequate FA. In addition, only mice exposed to adequate FA+ISO had microstructural improvements at the femur neck and higher serum osteoprotegrin (OPG) and insulin growth factor-I (IGF-I). In summary, exposure to supplemental FA did not enhance the positive effect of ISO in bone. However, exposure to adequate FA+ISO or supplemental FA improved bone at least in part by suppressing Dnmt3a and NPY. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Jee, Eun Hye; Kim, So Ra; Jang, Young Pyo
2012-08-17
A2E, known to be involved in the pathogenesis of age-related macular degeneration (AMD), is one of the major compounds that accumulate as fluorescent pigments in retinal pigment epithelial (RPE) cells with age and in some retinal disorders. While the biomimetic synthesis of A2E and its cis-isomer, iso-A2E is as simple as 'one-pot' reaction, the purification of these amphiphillic compounds has been a bottleneck for the mass production of these pathophysiologically important eye pigments. In order to provide a new method of rapid purification of A2E and iso-A2E, we employed a cation exchange resin for the separation of these pigments from crude reaction mixture. The reaction mixture was loaded on a weak acid resin and was eluted with 80% methanol with sodium hydroxide (pH 12), 100% methanol, and 100% methanol with 0.1% trifluoroacetic acid (TFA) in sequence. A2E and isoA2E were eluted only with 100% methanol solution containing TFA. Most of unreacted starting materials and intermediates were removed with 80% methanol containing sodium hydroxide. The new method can be used as a relatively simple and economic way to purify A2E and iso-A2E compared to conventional HPLC technique. Copyright © 2012 Elsevier B.V. All rights reserved.
Effect of a novel benzimidazole derivative in experimental Schistosoma mansoni infection.
El Bialy, Serry A; Taman, Amira; El-Beshbishi, Samar N; Mansour, Basem; El-Malky, Mohamed; Bayoumi, Waleed A; Essa, Hassan M
2013-12-01
Currently, praziquantel is the only drug of choice for treatment of schistosomiasis. Reports of praziquantel resistance raise concerns about future control of the disease. Therefore, the search for new schistosomicidal drugs is eminent. In this study, the effect of a novel benzimidazole-derived compound (compound BTP-Iso) was assessed in mice harboring adult Schistosoma mansoni (Egyptian strain). Mice were treated 42 days p.i. with compound BTP-Iso using two treatment regimens (200 or 300 mg/kg). In both regimens, there were significant reductions in the number of recovered S. mansoni worms especially females and in immature ova, in addition to a significant reduction in the number and size of hepatic granulomata. A dose of 300 mg/kg resulted in a significant decrease in intestinal and hepatic tissue egg loads. Effect on schistosomes was confirmed by scanning electron microscopy, where adult worms recovered from mice treated with 200 mg/kg of compound BTP-Iso revealed tegumental alternations, characterised by swelling of tegumental ridges, bleb formation, and mild erosion in male worms; however in females, there were extensive erosion and destruction of the tegumental surface. These promising results may encourage future use of compound BTP-Iso in the treatment of schistosomiasis. However, more research is needed to detect the effect of compound BTP-Iso on early developmental stages of S. mansoni and on other species of human schistosomes.
Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping
Augustsson, Per; Karlsen, Jonas T.; Su, Hao-Wei; Bruus, Henrik; Voldman, Joel
2016-01-01
Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic focusing of cell lines and leukocytes, showing that acoustic properties provide phenotypic information independent of size. PMID:27180912
Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping.
Augustsson, Per; Karlsen, Jonas T; Su, Hao-Wei; Bruus, Henrik; Voldman, Joel
2016-05-16
Mechanical phenotyping of single cells is an emerging tool for cell classification, enabling assessment of effective parameters relating to cells' interior molecular content and structure. Here, we present iso-acoustic focusing, an equilibrium method to analyze the effective acoustic impedance of single cells in continuous flow. While flowing through a microchannel, cells migrate sideways, influenced by an acoustic field, into streams of increasing acoustic impedance, until reaching their cell-type specific point of zero acoustic contrast. We establish an experimental procedure and provide theoretical justifications and models for iso-acoustic focusing. We describe a method for providing a suitable acoustic contrast gradient in a cell-friendly medium, and use acoustic forces to maintain that gradient in the presence of destabilizing forces. Applying this method we demonstrate iso-acoustic focusing of cell lines and leukocytes, showing that acoustic properties provide phenotypic information independent of size.
Sterilization validation for medical compresses at IRASM multipurpose irradiation facility
NASA Astrophysics Data System (ADS)
Alexandru, Mioara; Ene, Mihaela
2007-08-01
In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services—industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006.
Tropical intraseasonal oscillation simulated in an AMIP-type experiment by NICAM
NASA Astrophysics Data System (ADS)
Kikuchi, Kazuyoshi; Kodama, Chihiro; Nasuno, Tomoe; Nakano, Masuo; Miura, Hiroaki; Satoh, Masaki; Noda, Akira T.; Yamada, Yohei
2017-04-01
It is the first time for the non-hydrostatic icosahedral atmospheric model (NICAM), at a horizontal mesh size of approximately 14-km, to conduct a continuous long-term Atmospheric Model Intercomparison Project-type simulation. This study examines the performance of NICAM in simulating the tropical intraseasonal oscillation (ISO) from a statistical point of view using 30-year data (1979-2008) in the context of the bimodal ISO representation concept proposed by Kikuchi et al., which allows us to examine the seasonally varying behavior of the ISO in great detail, in addition to the MJO working group level 2 diagnostics. It is found that many of the fundamental features of the ISO are well captured by NICAM. The evolution of the ISO convection as well as large-scale circulation over the course of its life cycle is reasonably well reproduced throughout the year. As in the observation, the Madden-Julian oscillation (MJO) mode, characterized by prominent eastward propagation of convection, is predominant during boreal winter, whereas the boreal summer ISO (BSISO) mode, by a combination of pronounced eastward and northward propagation, during summer. The overall shape of the seasonal cycle as measured by the numbers of significant MJO and BSISO days in a month is relatively well captured. Two major biases, however, are also identified. The amplitude of the simulated ISO is weaker by a factor of 2. Significant BSISO events sometimes appear even during winter (December-April), amounting to 30 % of the total significant ISO days as opposed to 2 % in the observation. The results here warrant further studies using the simulation dataset to understand not only many aspects of the dynamics and physics of the ISO but also its role in weather and climate. It is also demonstrated that the concept of the bimodal ISO representation provides a useful framework for assessing model's capability to simulate, and illuminating model's deficiencies in reproducing, the ISO. The nature and causes of the two major biases are also discussed.
Schwalbe, H J; Bamfaste, G; Franke, R P
1999-01-01
Quality control in orthopaedic diagnostics according to DIN EN ISO 9000ff requires methods of non-destructive process control, which do not harm the patient by radiation or by invasive examinations. To obtain an improvement in health economy, quality-controlled and non-destructive measurements have to be introduced into the diagnostics and therapy of human joints and bones. A non-invasive evaluation of the state of wear of human joints and of the cracking tendency of bones is, as of today's point of knowledge, not established. The analysis of acoustic emission signals allows the prediction of bone rupture far below the fracture load. The evaluation of dry and wet bone samples revealed that it is possible to conclude from crack initiation to the bone strength and thus to predict the probability of bone rupture.
NASA Astrophysics Data System (ADS)
Varzakas, Theodoros H.; Arvanitoyannis, Ioannis S.
Failure Mode and Effect Analysis (FMEA) model has been applied for the risk assessment of poultry slaughtering and manufacturing. In this work comparison of ISO22000 analysis with HACCP is carried out over poultry slaughtering, processing and packaging. Critical Control points and Prerequisite programs (PrPs) have been identified and implemented in the cause and effect diagram (also known as Ishikawa, tree diagram and fishbone diagram).
Isoflurane reduces the ischemia reperfusion injury surge: a longitudinal study with MRI.
Taheri, Saeid; Shunmugavel, Anandakumar; Clark, Danielle; Shi, Honglian
2014-10-24
Recent studies show neuroprotective benefits of isoflurane (ISO) administered during cerebral ischemia. However, the available studies evaluated cerebral injury only at a single time point following the intervention and thus the longitudinal effect of ISO on ischemic tissues remains to be investigated. The objective of the present study was to investigate the longitudinal effect of ISO treatment in counteracting the deleterious effect of ischemia by evoking the transcription factor, hypoxia inducible factor-1 (HIF-1), and vascular endothelial growth factor (VEGF). Focal cerebral ischemia was induced in 70 rats by filament medial cerebral artery occlusion (MCAo) method. MCAo rats were randomly assigned to control (90 min ischemia) and MCAo+ISO (90 min ischemia+2% ISO) groups. Infarct volume, edema, intracerebral hemorrhage (ICH), and regional cerebral blood flow (rCBF) were measured in eight in vivo sequential MR imaging sessions for 3 weeks. Western blot analysis and immunofluorescence were used to determine the expression level of HIF-1α (the regulatable subunit of HIF-1) and VEGF proteins. ISO inhalation during ischemia significantly decreased the surge of infarct volume, edema, ICH, and reduced the mortality rate (p<0.01). ISO transiently altered the rCBF, significantly enhanced the expression of HIF-1α and VEGF, and decreased the immune cell infiltration. Locomotor dysfunction was ameliorated at a significantly faster pace, and the benefit was seen to persist up to three weeks. Treatment with ISO during ischemia limits the deadly surge in the dynamics of ischemia reperfusion injury with no observed long-term inverse effect. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Martinez, Ralph; Nam, Jiseung
1992-07-01
Picture Archiving and Communication Systems (PACS) is an integration of digital image formation in a hospital, which encompasses various imaging equipment, image viewing workstations, image databases, and a high speed network. The integration requires a standardization of communication protocols to connect devices from different vendors. The American College of Radiology and the National Electrical Manufacturers Association (ACR- NEMA) standard Version 2.0 provides a point-to-point hardware interface, a set of software commands, and a consistent set of data formats for PACS. But, it is inadequate for PACS networking environments, because of its point-to-point nature and its inflexibility to allow other services and protocols in the future. Based on previous experience of PACS developments in The University of Arizona, a new communication protocol for PACS networks and an approach were proposed to ACR-NEMA Working Group VI. The defined PACS protocol is intended to facilitate the development of PACS''s capable of interfacing with other hospital information systems. Also, it is intended to allow the creation of diagnostic information data bases which can be interrogated by a variety of distributed devices. A particularly important goal is to support communications in a multivendor environment. The new protocol specifications are defined primarily as a combination of the International Organization for Standardization/Open Systems Interconnection (ISO/OSI), TCP/IP protocols, and the data format portion of ACR-NEMA standard. This paper addresses the specification and implementation of the ISO-based protocol into a PACS prototype. The protocol specification, which covers Presentation, Session, Transport, and Network layers, is summarized briefly. The protocol implementation is discussed based on our implementation efforts in the UNIX Operating System Environment. At the same time, results of performance comparison between the ISO and TCP/IP implementations are presented to demonstrate the implementation of defined protocol. The testing of performance analysis is done by prototyping PACS on available platforms, which are Micro VAX II, DECstation and SUN Workstation.
2016-01-01
The aim of this study was to determine how representative wear scars of simulator-tested polyethylene (PE) inserts compare with retrieved PE inserts from total knee replacement (TKR). By means of a nonparametric self-organizing feature map (SOFM), wear scar images of 21 postmortem- and 54 revision-retrieved components were compared with six simulator-tested components that were tested either in displacement or in load control according to ISO protocols. The SOFM network was then trained with the wear scar images of postmortem-retrieved components since those are considered well-functioning at the time of retrieval. Based on this training process, eleven clusters were established, suggesting considerable variability among wear scars despite an uncomplicated loading history inside their hosts. The remaining components (revision-retrieved and simulator-tested) were then assigned to these established clusters. Six out of five simulator components were clustered together, suggesting that the network was able to identify similarities in loading history. However, the simulator-tested components ended up in a cluster at the fringe of the map containing only 10.8% of retrieved components. This may suggest that current ISO testing protocols were not fully representative of this TKR population, and protocols that better resemble patients' gait after TKR containing activities other than walking may be warranted. PMID:27597955
IGMS: An Integrated ISO-to-Appliance Scale Grid Modeling System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmintier, Bryan; Hale, Elaine; Hansen, Timothy M.
This paper describes the Integrated Grid Modeling System (IGMS), a novel electric power system modeling platform for integrated transmission-distribution analysis that co-simulates off-the-shelf tools on high performance computing (HPC) platforms to offer unprecedented resolution from ISO markets down to appliances and other end uses. Specifically, the system simultaneously models hundreds or thousands of distribution systems in co-simulation with detailed Independent System Operator (ISO) markets and AGC-level reserve deployment. IGMS uses a new MPI-based hierarchical co-simulation framework to connect existing sub-domain models. Our initial efforts integrate opensource tools for wholesale markets (FESTIV), bulk AC power flow (MATPOWER), and full-featured distribution systemsmore » including physics-based end-use and distributed generation models (many instances of GridLAB-D[TM]). The modular IGMS framework enables tool substitution and additions for multi-domain analyses. This paper describes the IGMS tool, characterizes its performance, and demonstrates the impacts of the coupled simulations for analyzing high-penetration solar PV and price responsive load scenarios.« less
Data resulting from the CFD analysis of ten window frames according to the UNI EN ISO 10077-2.
Baglivo, Cristina; Malvoni, Maria; Congedo, Paolo Maria
2016-09-01
Data are related to the numerical simulation performed in the study entitled "CFD modeling to evaluate the thermal performances of window frames in accordance with the ISO 10077" (Malvoni et al., 2016) [1]. The paper focuses on the results from a two-dimensional numerical analysis for ten frame sections suggested by the ISO 10077-2 and performed using GAMBIT 2.2 and ANSYS FLUENT 14.5 CFD code. The dataset specifically includes information about the CFD setup and boundary conditions considered as the input values of the simulations. The trend of the isotherms points out the different impacts on the thermal behaviour of all sections with air solid material or ideal gas into the cavities.
Demand Response For Power System Reliability: FAQ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, Brendan J
2006-12-01
Demand response is the most underutilized power system reliability resource in North America. Technological advances now make it possible to tap this resource to both reduce costs and improve. Misconceptions concerning response capabilities tend to force loads to provide responses that they are less able to provide and often prohibit them from providing the most valuable reliability services. Fortunately this is beginning to change with some ISOs making more extensive use of load response. This report is structured as a series of short questions and answers that address load response capabilities and power system reliability needs. Its objective is tomore » further the use of responsive load as a bulk power system reliability resource in providing the fastest and most valuable ancillary services.« less
Justification of system of assessment of ecological safety degree of housing construction objects
NASA Astrophysics Data System (ADS)
Kankhva, Vadim
2017-10-01
In article characteristics and properties of competitiveness of housing construction objects are investigated, criteria and points of national systems of ecological building’s standardization are structured, the compliance assessment form on stages of life cycle of a capital construction project is developed. The main indicators of level of ecological safety considering requirements of the international ISO standards 9000 and ISO 14000 and which are based on the basic principles of general quality management (TQM) are presented.
Pressure-dependent kinetics of initial reactions in iso-octane pyrolysis.
Ning, HongBo; Gong, ChunMing; Li, ZeRong; Li, XiangYuan
2015-05-07
This study focuses on the studies of the main pressure-dependent reaction types of iso-octane (iso-C8H18) pyrolysis, including initial C-C bond fission of iso-octane, isomerization, and β-scission reactions of the alkyl radicals produced by the C-C bond fission of iso-octane. For the C-C bond fission of iso-octane, the minimum energy potentials are calculated at the CASPT2(2e,2o)/6-31+G(d,p)//CAS(2e,2o)/6-31+G(d,p) level of theory. For the isomerization and the β-scission reactions of the alkyl radicals, the optimization of the geometries and the vibrational frequencies of the reactants, transition states, and products are performed at the B3LYP/CBSB7 level, and their single point energies are calculated by using the composite CBS-QB3 method. Variable reaction coordinate transition state theory (VRC-TST) is used for the high-pressure limit rate constant calculation and Rice-Ramsperger-Kassel-Marcus/master equation (RRKM/ME) is used to calculate the pressure-dependent rate constants of these channels with pressure varying from 0.01-100 atm. The rate constants obtained in this work are in good agreement with those available from literatures. We have updated the rate constants and thermodynamic parameters for species involved in these reactions into a current chemical kinetic mechanism and also have improved the concentration profiles of main products such as C3H6 and C4H6 in the shock tube pyrolysis of iso-octane. The results of this study provide insight into the pyrolysis of iso-octane and will be helpful in the future development of branched paraffin kinetic mechanisms.
Purification and characterisation of a novel iso-propanol dehydrogenase from Phytomonas sp.
Uttaro, A D; Opperdoes, F R
1997-04-01
An alcohol dehydrogenase with two identical subunits and a subunit molecular mass of 40,000 was purified from Phytomonas sp. isolated from the lactiferous tubes of Euphorbia characias. Digitonin titration and subcellular fractionation suggest that the enzyme is present in the mitochondrion. It utilises as substrates, primary and secondary alcohols, is specific for NAD+ as coenzyme and is inhibited by HgCl(2). The pH optimum for the oxidation of ethanol is 9.5, and for the reverse reaction 8.5. The apparent Km values for iso-propanol and ethanol are 40 and 34 microM, respectively and for the reverse reaction, with acetone as substrate, 14 microM. The respective specific activities with iso-propanol and ethanol as substrate, as measured in crude extracts are 300 and 16 mU (milligram of protein)-1. In isoelectric focusing the enzyme showed three major bands with slightly differing isoelectric points that ranged from 6.4 to 6.8. The name, iso-propanol dehydrogenase is proposed for this enzyme.
Isoform Sequencing and State-of-Art Applications for Unravelling Complexity of Plant Transcriptomes
An, Dong; Li, Changsheng; Humbeck, Klaus
2018-01-01
Single-molecule real-time (SMRT) sequencing developed by PacBio, also called third-generation sequencing (TGS), offers longer reads than the second-generation sequencing (SGS). Given its ability to obtain full-length transcripts without assembly, isoform sequencing (Iso-Seq) of transcriptomes by PacBio is advantageous for genome annotation, identification of novel genes and isoforms, as well as the discovery of long non-coding RNA (lncRNA). In addition, Iso-Seq gives access to the direct detection of alternative splicing, alternative polyadenylation (APA), gene fusion, and DNA modifications. Such applications of Iso-Seq facilitate the understanding of gene structure, post-transcriptional regulatory networks, and subsequently proteomic diversity. In this review, we summarize its applications in plant transcriptome study, specifically pointing out challenges associated with each step in the experimental design and highlight the development of bioinformatic pipelines. We aim to provide the community with an integrative overview and a comprehensive guidance to Iso-Seq, and thus to promote its applications in plant research. PMID:29346292
NASA Astrophysics Data System (ADS)
Dicecco, S.; Butcher, C.; Worswick, M.; Boettcher, E.; Chu, E.; Shi, C.
2016-11-01
The forming limit behaviour of AA6013-T6 aluminium alloy sheet was characterized under isothermal conditions at room temperature (RT) and 250°C using limiting dome height (LDH) tests. Full field strain measurements were acquired throughout testing using in situ stereoscopic digital image correlation (DIC) techniques. Limit strain data was generated from the resulting full field strain measurements using two localized necking criteria: ISO12004- 2:2008 and a time and position dependent criterion, termed the “Necking Zone” (NZ) approach in this paper, introduced by Martinez-Donaire et al. (2014). The limit strains resulting from the two localization detection schemes were compared. It was found that the ISO and NZ limit strains at RT are similar on the draw-side of the FLD, while the NZ approach yields a biaxial major limit strain 14.8% greater than the ISO generated major limit strain. At 250°C, the NZ generated major limit strains are 31-34% greater than the ISO generated major limit strains for near uniaxial, plane strain and biaxial loading conditions, respectively. The significant variance in limit strains between the two methodologies at 250°C highlights the need for a validation study regarding warm FLC determination.
75 FR 15362 - Demand Response Compensation in Organized Wholesale Energy Markets
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission 18 CFR Part 35 [Docket No. RM10-17-000... FERC ] 61,213, PJM Interconnection, LLC, Docket No. EL09-68-000 Notice of Proposed Rulemaking Table of... Emergency Demand Response; NYISO's Emergency Demand Response Program; PJM's Emergency Load Response; and ISO...
10 CFR 73.26 - Transportation physical protection systems, subsystems, components, and procedures.
Code of Federal Regulations, 2012 CFR
2012-01-01
...(s) shall be loaded into exclusive use cargo containers conforming to American National Standards Institute (ANSI) Standard MH5.1—“Basic Requirements for Cargo Containers” (1971) or International Standards Organization (ISO) 1496, “General Cargo Containers” (1978). Locks and seals shall be inspected by the escorts...
10 CFR 73.26 - Transportation physical protection systems, subsystems, components, and procedures.
Code of Federal Regulations, 2013 CFR
2013-01-01
...(s) shall be loaded into exclusive use cargo containers conforming to American National Standards Institute (ANSI) Standard MH5.1—“Basic Requirements for Cargo Containers” (1971) or International Standards Organization (ISO) 1496, “General Cargo Containers” (1978). Locks and seals shall be inspected by the escorts...
10 CFR 73.26 - Transportation physical protection systems, subsystems, components, and procedures.
Code of Federal Regulations, 2014 CFR
2014-01-01
...(s) shall be loaded into exclusive use cargo containers conforming to American National Standards Institute (ANSI) Standard MH5.1—“Basic Requirements for Cargo Containers” (1971) or International Standards Organization (ISO) 1496, “General Cargo Containers” (1978). Locks and seals shall be inspected by the escorts...
Arvanitoyannis, Ioannis S; Palaiokostas, Christos; Panagiotaki, Panagiota
2009-02-01
ISO 22000 is the new standard bound to replace HACCP on issues related to food safety. Although several companies, especially the big ones, have either implemented or are on the point of implementing ISO 22000, there are many others which are rather timid and/or reluctant to implement it. The main reason behind that is the lack of information and the fear that the new standard is too demanding in terms of bureaucratic work. This paper aims at making a comparative presentation of how the two systems can be applied to a small smoked salmon producing company thereby facilitating the emergence of the differences. The main difference is that in ISO 22000 systems like Good Manufacturing Practice and Good Hygiene Practice are prerequisites thus leading to lower number of CCPs. In this case study for example, the number of CCPs dropped from eight (8) in HACCP to four (4) in ISO 22000. Furthermore, the Failure Mode and Effect Analysis was applied to the smoked trout manufacturing process in an attempt to calculate quantitatively the Risk Priority Number (RPN) and to find out whether it can be effectively correlated to ISO 22000 and/or HACCP. RPN was found to be higher than 130 for eight steps, in close agreement with HACCP, thereby indicating that corrective actions will have to be undertaken.
Mullett, Mark; Fornarelli, Roberta; Ralph, David
2014-01-01
Two nanofiltration membranes, a Dow NF 270 polyamide thin film and a TriSep TS 80 polyamide thin film, were investigated for their retention of ionic species when filtering mine influenced water streams at a range of acidic pH values. The functional iso-electric point of the membranes, characterized by changes in retention over a small pH range, were examined by filtering solutions of sodium sulphate. Both membranes showed changes in retention at pH 3, suggesting a zero net charge on the membranes at this pH. Copper mine drainage and synthetic solutions of mine influenced water were filtered using the same membranes. These solutions were characterized by pH values within 2 and 5, thus crossing the iso-electric point of both membranes. Retention of cations was maximized when the feed solution pH was less than the iso-electric point of the membrane. In these conditions, the membrane has a net positive charge, reducing the transmission rate of cations. From the recoveries of a range of cations, the suitability of nanofiltration was discussed relative to the compliance with mine water discharge criteria and the recovery of valuable commodity metals. The nanofiltration process was demonstrated to offer advantages in metal recovery from mine waste streams, concomitantly enabling discharge criteria for the filtrate disposal to be met. PMID:24957170
Mayton, Alan G; Porter, William L; Xu, Xueyan S; Weston, Eric B; Rubenstein, Elaine N
2018-03-01
Workers who operate mine haul trucks are exposed to whole-body vibration (WBV) on a routine basis. Researchers from the National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Mining Research Division (PMRD) investigated WBV and hand-arm vibration (HAV) exposures for mine/quarry haul truck drivers in relation to the haul truck activities of dumping, loading, and traveling with and without a load. The findings show that WBV measures in weighted root-mean-square accelerations (a w ) and vibration dose value (VDV), when compared to the ISO/ANSI and European Directive 2002/44/EC standards, were mostly below the Exposure Action Value (EAV) identified by the health guidance caution zone (HGCZ). Nevertheless, instances were recorded where the Exposure Limit Value (ELV) was exceeded by more than 500 to 600 percent for VDV x and a wx , respectively. Researchers determined that these excessive levels occurred during the traveling empty activity, when the haul truck descended down grade into the pit loading area, sliding at times, on a wet and slippery road surface caused by rain and overwatering. WBV levels (not normalized to an 8-h shift) for the four haul truck activities showed mean a wz levels for five of the seven drivers exceeding the ISO/ANSI EAV by 9-53 percent for the traveling empty activity. Mean a wx and a wz levels were generally higher for traveling empty and traveling loaded and lower for loading/dumping activities. HAV for measures taken on the steering wheel and shifter were all below the HGCZ which indicates that HAV is not an issue for these drivers/operators when handling steering and shifting control devices.
Mayton, Alan G.; Porter, William L.; Xu, Xueyan S.; Weston, Eric B.; Rubenstein, Elaine N.
2018-01-01
Workers who operate mine haul trucks are exposed to whole-body vibration (WBV) on a routine basis. Researchers from the National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Mining Research Division (PMRD) investigated WBV and hand-arm vibration (HAV) exposures for mine/quarry haul truck drivers in relation to the haul truck activities of dumping, loading, and traveling with and without a load. The findings show that WBV measures in weighted root-mean-square accelerations (aw) and vibration dose value (VDV), when compared to the ISO/ANSI and European Directive 2002/44/EC standards, were mostly below the Exposure Action Value (EAV) identified by the health guidance caution zone (HGCZ). Nevertheless, instances were recorded where the Exposure Limit Value (ELV) was exceeded by more than 500 to 600 percent for VDVx and awx, respectively. Researchers determined that these excessive levels occurred during the traveling empty activity, when the haul truck descended down grade into the pit loading area, sliding at times, on a wet and slippery road surface caused by rain and overwatering. WBV levels (not normalized to an 8-h shift) for the four haul truck activities showed mean awz levels for five of the seven drivers exceeding the ISO/ANSI EAV by 9–53 percent for the traveling empty activity. Mean awx and awz levels were generally higher for traveling empty and traveling loaded and lower for loading/dumping activities. HAV for measures taken on the steering wheel and shifter were all below the HGCZ which indicates that HAV is not an issue for these drivers/operators when handling steering and shifting control devices. PMID:29725145
Irisin: a potentially candidate marker for myocardial infarction.
Kuloglu, Tuncay; Aydin, Suna; Eren, Mehmet Nesimi; Yilmaz, Musa; Sahin, Ibrahim; Kalayci, Mehmet; Sarman, Emine; Kaya, Nalan; Yilmaz, Osman Fatih; Turk, Ahmet; Aydin, Yalcin; Yalcin, Mehmet Hanifi; Uras, Nimet; Gurel, Ali; Ilhan, Selcuk; Gul, Evrim; Aydin, Suleyman
2014-05-01
Myocardial infarction (MI) causes energy depletion through imbalance between coronary blood supply and myocardial demand. Irisin produced by the heart reduces ATP production by increasing heat generation. Energy depletion affects irisin concentration in circulation and cardiac tissues, suggesting an association with MI. We examined: (1) irisin expression immunohistochemically in rat heart, skeletal muscle, kidney and liver in isoproterenol (ISO)-induced MI, and (2) serum irisin concentration by ELISA. Rats were randomly allocated into 6 groups (n=6), (i) control, (ii) ISO (1h), (iii) ISO (2h), (iv) ISO (4h), (v) ISO (6h), and (vi) ISO (24h), 200mg ISO in each case. Rats were decapitated and the blood and tissues collected for irisin analysis. Blood was centrifuged at 1792 g for 5 min. Tissues were washed with saline and fixed in 10% formalin for histology. Serum irisin levels gradually decreased from 1h to 24h in MI rats compared with controls, the minimum being at 2h, increasing again after 6h. Cardiac muscle cells, glomerular, peritubular renal cortical interstitial cells, hepatocytes and liver sinusoidal cells and perimysium, endomysium and nucleoi of skeletal muscle were irisin positive, but its synthesis decreased 1-4h after MI. At all time-points, irisin increased near myocardial connective tissue, with production in skeletal muscle, liver and kidney recovering after 6h, although slower than controls. Unique insight into the pathogenesis of MI is shown, and the gradually decrease of serum irisin might be a diagnostic marker for MI. Copyright © 2014 Elsevier Inc. All rights reserved.
Coordination and decision making of regulation, operation, and market activities in power systems
NASA Astrophysics Data System (ADS)
Nakashima, Tomoaki
Electric power has been traditionally supplied to customers at regulated rates by vertically integrated utilities (VIUs), which own generation, transmission, and distribution systems. However, the regulatory authorities of VIUs are promoting competition in their businesses to lower the price of electric energy. Consequently, in new deregulated circumstances, many suppliers and marketers compete in the generation market, and conflict of interest may often occur over transmission. Therefore, a neutral entity, called an independent system operator (ISO), which operates the power system independently, has been established to give market participants nondiscriminatory access to transmission sectors with a natural monopoly, and to facilitate competition in generation sectors. Several types of ISOs are established at present, with their respective regions and authorities. The ISO receives many requests from market participants to transfer power, and must evaluate the feasibility of their requests under the system's condition. In the near future, regulatory authorities may impose various objectives on the ISOs. Then, based on the regulators' policies, the ISO must determine the optimal schedules from feasible solutions, or change the market participants' requests. In a newly developed power market, market participants will conduct their transactions in order to maximize their profit. The most crucial information in conducting power transactions is price and demand. A direct transaction between suppliers and consumers may become attractive because of its stability of price, while in a power exchange market, gaming and speculation of participants may push up electricity prices considerably. To assist the consumers in making effective decisions, suitable methods for forecasting volatile market price are necessary. This research has been approached from three viewpoints: Firstly, from the system operator's point of view, desirable system operation and power market structure are explored. Two typical ISO models, centralized and decentralized, have been identified and compared. These ISO models have been simulated to observe the advantages and disadvantages of the different systems. If no powerful players exist, the centralized system would achieve the maximum market efficiency. However, in decentralized systems, freedom of trade protects market participants from strategic bidding caused by powerful players. Reduced market efficiency is the price markets have to pay to prevent strategic bidding. Secondly, from the regulator's point of view, the effects of different policies imposed by regulators on power transactions are examined. The optimal schedule could be affected greatly by the ideal goals and their allowable values. Therefore, when the ISO defines its objectives and their allowable ranges, an agreeable conclusion among market participants is required. Fuzzy multiobjective optimization methods can be suitably applied to the scheduling of the ISO, reflecting its objectives and their allowable ranges properly. Thirdly, from market participants' point of view, models to represent and forecast the price and demand of power are developed. Electricity consumption and price are forecasted based on possibility theory and fuzzy autoregression. The fuzzy model can represent highly volatile demand-price relations as a range, and gives the possibility distribution of prices. Based on the proposed model, a procedure to help consumers decide whether to accept a bilateral transaction contract or market-based purchases of electricity has been developed. The same procedure can also be used by an electricity supplier or broker to determine an offering price.
Ittianuwat, R; Fard, M; Kato, K
2017-01-01
Although much research has been done in developing the current ISO 2631-1 (1997) standard method for assessment seat vibration comfort, little consideration has been given to the influence of vehicle seat structural dynamics on comfort assessment. Previous research has shown that there are inconsistencies between standard methods and subjective evaluation of comfort at around vehicle seat twisting resonant frequencies. This study reports the frequency-weighted r.m.s. accelerations in [Formula: see text], [Formula: see text] and [Formula: see text] axes and the total vibration (point vibration total value) at five locations on seatback surface at around vehicle seat twisting resonant frequencies. The results show that the vibration measured at the centre of seatback surface, suggested by current ISO 2631-1 (1997), at around twisting resonant frequencies was the least for all tested vehicle seats. The greatest point vibration total value on the seatback surface varies among vehicle seats. The variations in vibration measured at different locations on seatback surface at around twisting resonant frequencies were sufficiently great that might affect the comfort assessment of vehicle seat.Practitioner Summary: The influence of vehicle seat structural dynamics has not been considered in current ISO 2631-1 (1997). The results of this study show that the vibration measures on seatback surface at around vehicle seat twisting resonant frequency depends on vehicle seats and dominate at the top or the bottom of seatback but not at the centre.
1976-03-01
MAO RX 10- 6 PHI CONF L OEL 6 50 0. 92 1.7 0.0 B2H2F12 16 CH3 C8 3 • ISO XCPF3 0.0576 0 0 0 0...8650 8583 5461 0134_ 6 13J 0364_ 6174 3887_ 7232" 84o8 -4 _^3 -2 -3 .1803 .8923 .8849 .1944 O o Ol o NAVAL SHIP RESEARCH AND...14.59 0 0. 0969 1189 -0.3166 -0.3444 ,4130 ,5778 -9.7355 -9.8483 0.0120 0.0 ISO 0.Ö120 0.0130 0.2128 0.2443 Ŕ.2616 0.2760 0.2*907
Assessment of opacimeter calibration according to International Standard Organization 10155.
Gomes, J F
2001-01-01
This paper compares the calibration method for opacimeters issued by the International Standard Organization (ISO) 10155 with the manual reference method for determination of dust content in stack gases. ISO 10155 requires at least nine operational measurements, corresponding to three operational measurements per each dust emission range within the stack. The procedure is assessed by comparison with previous calibration methods for opacimeters using only two operational measurements from a set of measurements made at stacks from pulp mills. The results show that even if the international standard for opacimeter calibration requires that the calibration curve is to be obtained using 3 x 3 points, a calibration curve derived using 3 points could be, at times, acceptable in statistical terms, provided that the amplitude of individual measurements is low.
SCRIBE (Stratospheric Cryogenic Interferometer Baloon Experiment) Data Survey and Validation.
1987-02-16
Altitude of 27000 to 28000 m, SPIE Publ. 366, p165-172, AD-A133 472. 5 ferometer 3 and to point out flaws in the system which were subsequently...Tangent Height - 16.9 km * 6 j4 II’ a. WA#EUM k CM p Altitude = 31.3 km ’ / Zenith Angle = 93.7 deg.- ouTangent Height = 16.9 km I- + p ISO . .. .. 0...Height = 30.47 106 250 200 ISO ........................., .................................. ’ 65S 660 665 670 675 WAVENUMBER (CM-1) Figure 31. Comparison
Advanced Acoustic Model Technical Reference and User Manual
2009-05-01
the source directed from the source to the receiver. Aspread = Geometrical spherical spreading loss (point source). Aatm = ANSI/ ISO atmospheric...426.1 1,013.4 27000 722 422.5 1,009.2 28000 691 418.9 1,004.9 29000 660 415.4 1,000.6 30000 631 411.8 996.4 A d v a n c e d A c o u s t i c M...sound by molecular relaxation processes in the atmosphere is computed according to the current ANSI/ ISO standard.28 Examples of the weather effects
Advanced Acoustic Model Technical Reference and User Manual
2010-09-01
loss (point source). Aatm = ANSI/ ISO atmospheric absorption standard.28 Agrd = Ground reflection and attenuation losses, caused by the ground and the...433.2 1,021.8 25000 788 429.6 1,017.6 26000 754 426.1 1,013.4 27000 722 422.5 1,009.2 28000 691 418.9 1,004.9 29000 660 415.4 1,000.6 30000 631...ANSI/ ISO standard.28 Examples of the weather effects are described here. Consider a situation with winds approximately blowing from NW to SE. Figure 2
40 CFR 435.11 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Extraction Point Source Category,” EPA-821-R-11-004. See paragraph (uu) of this section. (e) Biodegradation... Bottle Biodegradation Test System: Modified ISO 11734:1995,” EPA Method 1647, supplemented with...
40 CFR 435.11 - Specialized definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Extraction Point Source Category,” EPA-821-R-11-004. See paragraph (uu) of this section. (e) Biodegradation... Bottle Biodegradation Test System: Modified ISO 11734:1995,” EPA Method 1647, supplemented with...
40 CFR 435.11 - Specialized definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Extraction Point Source Category,” EPA-821-R-11-004. See paragraph (uu) of this section. (e) Biodegradation... Bottle Biodegradation Test System: Modified ISO 11734:1995,” EPA Method 1647, supplemented with...
Real-time anomaly detection for very short-term load forecasting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Jian; Hong, Tao; Yue, Meng
Although the recent load information is critical to very short-term load forecasting (VSTLF), power companies often have difficulties in collecting the most recent load values accurately and timely for VSTLF applications. This paper tackles the problem of real-time anomaly detection in most recent load information used by VSTLF. This paper proposes a model-based anomaly detection method that consists of two components, a dynamic regression model and an adaptive anomaly threshold. The case study is developed using the data from ISO New England. This paper demonstrates that the proposed method significantly outperforms three other anomaly detection methods including two methods commonlymore » used in the field and one state-of-the-art method used by a winning team of the Global Energy Forecasting Competition 2014. Lastly, a general anomaly detection framework is proposed for the future research.« less
Real-time anomaly detection for very short-term load forecasting
Luo, Jian; Hong, Tao; Yue, Meng
2018-01-06
Although the recent load information is critical to very short-term load forecasting (VSTLF), power companies often have difficulties in collecting the most recent load values accurately and timely for VSTLF applications. This paper tackles the problem of real-time anomaly detection in most recent load information used by VSTLF. This paper proposes a model-based anomaly detection method that consists of two components, a dynamic regression model and an adaptive anomaly threshold. The case study is developed using the data from ISO New England. This paper demonstrates that the proposed method significantly outperforms three other anomaly detection methods including two methods commonlymore » used in the field and one state-of-the-art method used by a winning team of the Global Energy Forecasting Competition 2014. Lastly, a general anomaly detection framework is proposed for the future research.« less
Schurr, Frank; Cougoule, Nicolas; Rivière, Marie-Pierre; Ribière-Chabert, Magali; Achour, Hamid; Ádám, Dán; Castillo, Carlos; de Graaf, Dirk C; Forsgren, Eva; Granato, Anna; Heinikainen, Sirpa; Jurovčíková, Júlia; Kryger, Per; Manson, Christine; Ménard, Marie-Françoise; Perennes, Stéphane; Schäfer, Marc O; Ibañez, Elena San Miguel; Silva, João; Gajger, Ivana Tlak; Tomkies, Victoria; Toplak, Ivan; Viry, Alain; Zdańska, Dagmara; Dubois, Eric
2017-10-01
The Chronic bee paralysis virus (CBPV) is the aetiological agent of chronic bee paralysis, a contagious disease associated with nervous disorders in adult honeybees leading to massive mortalities in front of the hives. Some of the clinical signs frequently reported, such as trembling, may be confused with intoxication syndromes. Therefore, laboratory diagnosis using real-time PCR to quantify CBPV loads is used to confirm disease. Clinical signs of chronic paralysis are usually associated with viral loads higher than 10 8 copies of CBPV genome copies per bee (8 log 10 CBPV/bee). This threshold is used by the European Union Reference Laboratory for Bee Health to diagnose the disease. In 2015, the accuracy of measurements of three CBPV loads (5, 8 and 9 log 10 CBPV/bee) was assessed through an inter-laboratory study. Twenty-one participants, including 16 European National Reference Laboratories, received 13 homogenates of CBPV-infected bees adjusted to the three loads. Participants were requested to use the method usually employed for routine diagnosis. The quantitative results (n=270) were analysed according to international standards NF ISO 13528 (2015) and NF ISO 5725-2 (1994). The standard deviations of measurement reproducibility (S R ) were 0.83, 1.06 and 1.16 at viral loads 5, 8 and 9 log 10 CBPV/bee, respectively. The inter-laboratory confidence of viral quantification (+/- 1.96S R ) at the diagnostic threshold (8 log 10 CBPV/bee) was+/- 2.08 log 10 CBPV/bee. These results highlight the need to take into account the confidence of measurements in epidemiological studies using results from different laboratories. Considering this confidence, viral loads over 6 log 10 CBPV/bee may be considered to indicate probable cases of chronic paralysis. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Metrology for hydrogen energy applications: a project to address normative requirements
NASA Astrophysics Data System (ADS)
Haloua, Frédérique; Bacquart, Thomas; Arrhenius, Karine; Delobelle, Benoît; Ent, Hugo
2018-03-01
Hydrogen represents a clean and storable energy solution that could meet worldwide energy demands and reduce greenhouse gases emission. The joint research project (JRP) ‘Metrology for sustainable hydrogen energy applications’ addresses standardisation needs through pre- and co-normative metrology research in the fast emerging sector of hydrogen fuel that meet the requirements of the European Directive 2014/94/EU by supplementing the revision of two ISO standards that are currently too generic to enable a sustainable implementation of hydrogen. The hydrogen purity dispensed at refueling points should comply with the technical specifications of ISO 14687-2 for fuel cell electric vehicles. The rapid progress of fuel cell technology now requires revising this standard towards less constraining limits for the 13 gaseous impurities. In parallel, optimized validated analytical methods are proposed to reduce the number of analyses. The study aims also at developing and validating traceable methods to assess accurately the hydrogen mass absorbed and stored in metal hydride tanks; this is a research axis for the revision of the ISO 16111 standard to develop this safe storage technique for hydrogen. The probability of hydrogen impurity presence affecting fuel cells and analytical techniques for traceable measurements of hydrogen impurities will be assessed and new data of maximum concentrations of impurities based on degradation studies will be proposed. Novel validated methods for measuring the hydrogen mass absorbed in hydrides tanks AB, AB2 and AB5 types referenced to ISO 16111 will be determined, as the methods currently available do not provide accurate results. The outputs here will have a direct impact on the standardisation works for ISO 16111 and ISO 14687-2 revisions in the relevant working groups of ISO/TC 197 ‘Hydrogen technologies’.
ISO completes its observations of the Universe by infrared light
NASA Astrophysics Data System (ADS)
1998-04-01
At 07:00 on 8 April 1998, engineers at ESA's ground station at Villafranca near Madrid reported that ISO's telescope was beginning to warm up, above its nominal operating temperature close to absolute zero. This was the sign that ISO had exhausted the superfluid helium used to achieve the very low temperatures necessary for infrared astronomy. Observations ceased at 23h07 when the temperature of the instruments had risen above -269°C. At that time, ISO was observing the galaxy NGC 1808 with the camera (ISOCAM) for Prof. J. Hough (UK). The astronomers then handed ISO over to the engineering team for check-outs and decommissioning. The spacecraft will be switched off in about 28 days' time. Infrared rays come from cool places in the sky, and ISO would have been dazzled by its own heat unless its optical system were extremely cold. At its launch in November 1995, ISO carried a supply of 2000 litres of superfluid helium, which boils at -271 degrees C. Slow venting of the helium into space maintained the low temperature of the optical system. How did ISO achieve its extended life? Three months came from a prudent safety margin in the engineering calculations of the rate of loss of helium. Two months were the result of favourable circumstances in the launch campaign at Kourou in French Guiana. During a technical check of the Ariane 44P launcher, ISO's engineers seized the chance to recharge the helium, and the quick launch that followed meant that the outer parts of the cryogenic system of the spacecraft had little time to warm up in Kourou's tropical climate. Finally, the daily loss of helium turned out to be 17 less than expected, at the lower end of a range of possibilities considered by the engineers. That gave ISO an estimated five months of additional life. The date for the helium to run out remained somewhat uncertain, and astronomers and engineers have been alert to the possibility of its exhaustion for the past few weeks. The huge bonus to astronomers, from ISO's long operating life, is only one of their reasons to be grateful for the highly successful engineering and operations of ISO. The pointing accuracy of ISO's telescope was ten times better than required by the specification, and its jitter was one-fifth of what would have been considered tolerable. Smooth, well-planned operations were extended on a daily basis by a US ground station supporting ESA's Villafranca station. ISO was observing selected targets in the sky for 90-95 of the time available. Even in between the planned observations a "serendipity" programme with the ISOPHOT instrument charted cool objects as ISO slewed from one target to the next. Although ISO's observations are now completed, astronomers will be analysing them for years to come, assisted by a team of mission experts who will continue their work at Villafranca and other centres worldwide until 2001. Commenting on the completion of ISO's observational phase, ESA's director of science, Roger Bonnet, says: "We always knew that ISO's helium would run out one day, and we can be grateful that it has lasted for so long. This is a time for celebration, not sorrow, and I congratulate the VILSPA, ESTEC and ESOC staff who have operated so efficiently the spacecraft as well as European industry which developed such an excellent mission and our scientists who built such an outstanding payload . I wish European astronomers as well as their colleagues from the USA and Japan to now fully exploit the image data acquired by ISO". For further information, please contact : ESA Public Relations Division Martin Kessler Tel: +33(0)1.53.69.71.55 ISO Project Scientist Fax: +33(0)1.53.69.76.90 Tel :+34 (9)1.813.1253 e-mail: mkessler @iso.vilspa.esa.es For background information, consult ISO's wwwpages at : isowww.estec.esa.nl
Life Cycle Assessment (ISO 14040) implementation in foods of animal and plant origin: review.
Arvanitoyannis, Ioannis S; Kotsanopoulos, Konstantinos V; Veikou, Agapi
2014-01-01
The importance of environmental protection has been recently upgraded due to the continuously increasing environmental pollution load. Life Cycle Assessment (LCA), wellknown as ISO 14040, has been repeatedly shown to be a useful and powerful tool for assessing the environmental performance of industrial processes, both in the European and American continents as well as in many Asian countries (such as Japan and China). To the best of our knowledge, almost no information is provided in relation to LCA implementation in Africa apart from an article related to Egypt. Although food industries are not considered to be among the most heavily polluting ones, for some like olive oil, wine, dairy, and meat processing, their impact on the environment is a heavy burden. The introduction of LCA aimed at identifying both inputs and outputs to find out which are the most detrimental to the environment in terms of water/energy consumption and solid/liquid and gas releases. In this review, a thorough coverage of literature was made in an attempt to compare the implementation of LCA to a variety of products of both plant and animal origin. It was concluded that there is a high number of subsystems suggested for the same product, thereby, occasionally leading to confusion. An idea toward solving the problem is to proceed to some sort of standardization by means of several generic case studies of LCA implementation, similarly to what had happened in the case of Hazard Analysis and Critical Control Points (HACCP) implementation in the United States, Canada, Australia, United Kingdom, and other countries.
Kiuru, Eveliina; Kokki, Hannu; Juvonen, Petri; Lintula, Hannu; Paajanen, Hannu; Gissler, Mika; Eskelinen, Matti
2014-01-01
The impact of the age and sex adjusted body mass index (ISO-BMI) in the obese vs. non-obese children and adolescents with cholecystectomy for cholelithias is rarely reported. The national database was searched for cholecystectomies performed in paediatric patients between 1997 and 2011, and the 59 paediatric and adolescent patients having cholecystectomy in the Kuopio University Hospital district were divided in two groups by age and sex adjusted BMI (ISO-BMI) using the cut-off point of overweight (ISO-BMI 25 kg/m(2)) based on the Finnish growth standards. Nationwide a total of 840 cholecystectomies were performed during the 15 years study period in Finland, most of which included females (77%), resulting in a mean of annual frequency of 4.8 (range: 3.9-6.1) procedures/100,000 population. In the study sample, most of the patients with the cholelithiasis were female (50/59, 85%). The gender distribution was equal among the younger patients, but among adolescents 6/52 (12%) of the patients with cholelithiasis were boys and 46/52 (88%) of the patients with cholelithiasis were girls. Obesity did not affect on operative parameters. The median operative time was 70 min (range, 30-155) and 66 min (44-130) in the high ISO-BMI-group. The recovery was similar in the two groups: the median length of hospital stay was 4 days in both groups. The patients in the low ISO-BMI-group vs. high ISO-BMI-group had a trend of higher serum bilirubin (p=0.16) and serum AFOS values (p=0.19). In the histological examination of the gallbladders 19/28 (68%) patients in the low ISO-BMI-group had inflammation vs. 26/31 (84%) patients in the high ISO-BMI-group (p=0.15). Our results between obese and non-obese children and adolescents with cholelithiasis are not statistically significant. The obese adolescents with female gender are in greater risk for cholelithiasis. Copyright © 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Piacentino, Valentino; Gaughan, John P; Houser, Steven R
2002-03-08
Phosphorylation of Na channels has been suggested to increase their Ca permeability. Termed "slip-mode conductance" (SMC), this hypothesis predicts that Ca influx via protein kinase A (PKA)-modified Na channels can induce sarcoplasmic reticulum (SR) Ca release. We tested this hypothesis by determining if SR Ca release is graded with I(Na) in the presence of activated PKA (with Isoproterenol, ISO). V(m), I(m), and [Ca](i) were measured in feline (n=26) and failing human (n=19) ventricular myocytes. Voltage steps from -70 through -40 mV were used to grade I(Na). Na channel antagonists (tetrodotoxin), L-type Ca channel (I(Ca,L)) antagonists (nifedipine, cadmium, verapamil), and agonists (Bay K 8644, FPL 64176) were used to separate SMC from I(Ca,L). In the absence of ISO, I(Na) was associated with SR Ca release in human but not feline myocytes. After ISO, graded I(Na) was associated with small amounts of SR Ca release in feline myocytes and the magnitude of release increased in human myocytes. I(Na)-related SR Ca release was insensitive to tetrodotoxin (n=10) but was blocked by nifedipine (n=10) and cadmium (n=3). SR Ca release was induced over the same voltage range in the absence of ISO with Bay K 8644 and FPL 64176 (n=9). Positive voltage steps (to 0 mV) to fully activate Na channels (SMC) in the presence of ISO and Verapamil only caused SR Ca release when block of I(Ca,L) was incomplete. We conclude that PKA-mediated increases in I(Ca,L) and SR Ca loading can reproduce many of the experimental features of SMC.
Using Supercomputers to Speed Execution of the CAISO/PLEXOS 33% RPS Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyers, C; Streitz, F; Yao, Y
2011-09-19
The study's official title is 'ISO Study of Operational Requirements and Market Impacts at 33% Renewable Portfolio Standard (RPS).' The stated objectives are twofold: (1) identifying operational requirements and resource options to reliably operate the ISO-controlled grid under a 33% RPS in 2020; and (2) inform market, planning, and policy/regulatory decisions by the ISO, state agencies, market participants, and other stakeholders. The first of these objectives requires the hourly estimates of integration requirements, measured in terms of operational ramp, load following and regulation capacity and ramp rates, as well as additional capacity to resolve operational violations. It also involves considerationmore » of other variables that affect the results, such as the impact of different mixes of renewable technologies, and the impact of forecasting error and variability. The second objective entails supporting the CPUC to identify long-term procurement planning needs, costs, and options, as well as informing other decisions made by the CPUC and state agencies. For the ISO itself this includes informing state-wide transmission planning needs for renewables up to a 33% RPS, and informing design of wholesale markets for energy and ancillary services to facilitate provision of integration capacities. The study is designed in two phases. The first (current) phase is focused on operational requirements and addressing these requirements with existing and new conventional fossil generation; for instance, gas turbines and/or combined cycle units. The second (planned) phase will address the same operational requirements with a combination of conventional fossil generation resources, new non-generation resources, and a renewable resource dispatch. There are seven different scenarios considered in the current phase: a 20% RPS reference case; four 33% RPS cases (a reference case, a high out-of-state case, a high distributed generation case, and a low load case); an alternative 27.5% RPS case; and an all-gas case (no new renewables after 2008). In addition, the CPUC is planning a new set of cases that will alter the anticipated sets of runs.« less
Asteroids as Calibration Standards in the Thermal Infrared -- Applications and Results from ISO
NASA Astrophysics Data System (ADS)
Müller, T. G.; Lagerros, J. S. V.
Asteroids have been used extensively as calibration sources for ISO. We summarise the asteroid observational parameters in the thermal infrared and explain the important modelling aspects. Ten selected asteroids were extensively used for the absolute photometric calibration of ISOPHOT in the far-IR. Additionally, the point-like and bright asteroids turned out to be of great interest for many technical tests and calibration aspects. They have been used for testing the calibration for SWS and LWS, the validation of relative spectral response functions of different bands, for colour correction and filter leak tests. Currently, there is a strong emphasis on ISO cross-calibration, where the asteroids contribute in many fields. Well known asteroids have also been seen serendipitously in the CAM Parallel Mode and the PHT Serendipity Mode, allowing for validation and improvement of the photometric calibration of these special observing modes.
IEEE/NASA Workshop on Leveraging Applications of Formal Methods, Verification, and Validation
NASA Technical Reports Server (NTRS)
Margaria, Tiziana (Editor); Steffen, Bernhard (Editor); Hichey, Michael G.
2005-01-01
This volume contains the Preliminary Proceedings of the 2005 IEEE ISoLA Workshop on Leveraging Applications of Formal Methods, Verification, and Validation, with a special track on the theme of Formal Methods in Human and Robotic Space Exploration. The workshop was held on 23-24 September 2005 at the Loyola College Graduate Center, Columbia, MD, USA. The idea behind the Workshop arose from the experience and feedback of ISoLA 2004, the 1st International Symposium on Leveraging Applications of Formal Methods held in Paphos (Cyprus) last October-November. ISoLA 2004 served the need of providing a forum for developers, users, and researchers to discuss issues related to the adoption and use of rigorous tools and methods for the specification, analysis, verification, certification, construction, test, and maintenance of systems from the point of view of their different application domains.
ISO(4,1) symmetry in the EFT of inflation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Creminelli, Paolo; Emami, Razieh; Simonović, Marko
In DBI inflation the cubic action is a particular linear combination of the two, otherwise independent, cubic operators π-dot {sup 3} and π-dot (∂{sub i}π){sup 2}. We show that in the Effective Field Theory (EFT) of inflation this is a consequence of an approximate 5D Poincar and apos;e symmetry, ISO(4,1), non-linearly realized by the Goldstone π. This symmetry uniquely fixes, at lowest order in derivatives, all correlation functions in terms of the speed of sound c{sub s}. In the limit c{sub s} → 1, the ISO(4,1) symmetry reduces to the Galilean symmetry acting on π. On the other hand, wemore » point out that the non-linear realization of SO(4,2), the isometry group of 5D AdS space, does not fix the cubic action in terms of c{sub s}.« less
1975-04-30
JH’iA «4.1 UP SINGLE SYSTEM LOG ISO BLU-ELtll-ELECTRIC BEMANO PBOFIU 01EN 110MHH C’S J538DOI JPK ". t s MW ObPW 4...55 Start-Stop Programs 55 1 .xpansion Capacity 27000 points with added channels and memory tNVIRONMHNTAL: +32 to I05F. 95’? RH maximum POWBR...JC/80 System remedies this deficiency since data transmitted over telephone lines is limited to exceptions" B^T "I V. J 13 iso * i it is
It's All Relative: A Validation of Radiation Quality Comparison Metrics
NASA Technical Reports Server (NTRS)
Chappell, Lori J.; Milder, Caitlin M.; Elgart, S. Robin; Semones, Edward J.
2017-01-01
The difference between high-LET and low-LET radiation is quantified by a measure called relative biological effectiveness (RBE). RBE is defined as the ratio of the dose of a reference radiation to that of a test radiation to achieve the same effect level, and thus, is described either as an iso-effector dose-to-dose ratio. A single dose point is not sufficient to calculate an RBE value; therefore, studies with only one dose point usually calculate an effect-to-effect ratio. While not formally used in radiation protection, these iso-dose values may still be informative. Shuryak, et al 2017 investigated the use of an iso-dose metric termed "radiation effects ratio" (RER) and used both RBE and RER to estimate high-LET risks. To apply RBE or RER to risk prediction, the selected metric must be uniquely defined. That is, the calculated value must be consistent within a model given a constant set of constraints and assumptions, regardless of how effects are defined using statistical transformations from raw endpoint data. We first test the RBE and the RER to determine whether they are uniquely defined using transformations applied to raw data. Then, we test whether both metrics can predict heavy ion response data after simulated effect size scaling between human populations or when converting animal to human endpoints.
Miyaguchi, Kazuyoshi; Demura, Shinichi
2006-05-01
The purpose of this study was to examine the output properties of muscle power by the dominant upper limb using SSC, and the relationships between the power output by SSC and a one-repetition maximum bench press (1 RM BP) used as a strength indicator of the upper body. Sixteen male athletes (21.4+/-0.9 yr) participated in this study. They pulled a load of 40% of maximum voluntary contraction (MVC) at a stretch by elbow flexion of the dominant upper limb in the following three preliminary conditions: static relaxed muscle state (SR condition), isometric muscle contraction state (ISO condition), and using SSC (SSC condition). The velocity with a wire load via a pulley during elbow flexion was measured accurately using a power instrument with a rotary encoder, and the muscle power curve was drawn from the product of the velocity and load. Significant differences were found among all evaluation parameters of muscle power exerted from the above three conditions and the parameters regarding early power output during concentric contraction were larger in the SSC condition than the SR and ISO conditions. The parameters on initial muscle contraction velocity when only using SSC significantly correlated with 1 RM BP (r=0.60-0.62). The use of SSC before powerful elbow flexion may contribute largely to early explosive power output during concentric contraction. Bench press capacity relates to a development of the above early power output when using SSC.
Comparison of Wind Power and Load Forecasting Error Distributions: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodge, B. M.; Florita, A.; Orwig, K.
2012-07-01
The introduction of large amounts of variable and uncertain power sources, such as wind power, into the electricity grid presents a number of challenges for system operations. One issue involves the uncertainty associated with scheduling power that wind will supply in future timeframes. However, this is not an entirely new challenge; load is also variable and uncertain, and is strongly influenced by weather patterns. In this work we make a comparison between the day-ahead forecasting errors encountered in wind power forecasting and load forecasting. The study examines the distribution of errors from operational forecasting systems in two different Independent Systemmore » Operator (ISO) regions for both wind power and load forecasts at the day-ahead timeframe. The day-ahead timescale is critical in power system operations because it serves the unit commitment function for slow-starting conventional generators.« less
Injury risk curves for the WorldSID 50th male dummy.
Petitjean, Audrey; Trosseille, Xavier; Praxl, Norbert; Hynd, David; Irwin, Annette
2012-10-01
The development of the WorldSID 50th percentile male dummy was initiated in 1997 by the International Organisation for Standardisation (ISO/TC22/SC12/WG5) with the objective of developing a more biofidelic side impact dummy and supporting the adoption of a harmonised dummy into regulations. The dummy is currently under evaluation at the Working Party on Passive Safety (GRSP) in order to be included in the pole side impact global technical regulation (GTR). Injury risk curves dedicated to this dummy and built on behalf of ISO/TC22/SC12/WG6 were proposed in order to assess the occupant safety performance (Petitjean et al. 2009). At that time, there was no recommendation yet on the injury criteria and no consensus on the most accurate statistical method to be used. Since 2009, ISO/TC22/SC12/WG6 reached a consensus on the definition of guidelines to build injury risk curves, including the use of the survival analysis, the distribution assessment and quality checks. These guidelines were applied to the WorldSID 50th results published in 2009 in order to be able to provide a final set of injury risk curves recommended by ISO/TC22/SC12/WG6. The paper presents the different steps of the guidelines as well as the recommended injury risk curves dedicated to the WorldSID 50th for lateral shoulder load, thoracic rib deflection, abdomen rib deflection and pubic force.
Role of standard documents in advancing the standardization of microfluidics connectors
NASA Astrophysics Data System (ADS)
Tantra, Ratna; van Heeren, Henne; Jarman, John
2016-04-01
An emerging trend within the microfluidic community is to standardize common parts in order to facilitate design and production activities. The goal is clear: to enhance interoperability and promote plug-and-play. A recent launch of a pan-European project, Microfluidic (MF) Manufacturing, has identified an item that is in immediate need of standardization: having in place geometrical specifications for MF connectors. In order to accelerate the adoption of such standards, there is a need to consider the pivotal role of standard documents. The purpose of this paper is to provide background information on document standards development. In addition, the future implications related to the MF manufacturing project will be discussed. A strengths, weaknesses, opportunities, and threats analysis has been carried out to identify points of action. The findings show that although there is a need to publish under International Organization for Standardization (ISO), the actual realization of a full ISO standard document is not feasible. The recommendation is to initially publish via an ISO Workshop Agreement. Parallel to such activity, there is a need to encourage stakeholders help kick start a currently dormant working group that supports microfluidics under ISO to help pave the way for future standardization activities in the microfluidics community.
Wolde, Mistire; Tarekegn, Getahun; Kebede, Tedla
2018-05-01
Point-of-care glucometer (PoCG) devices play a significant role in self-monitoring of the blood sugar level, particularly in the follow-up of high blood sugar therapeutic response. The aim of this study was to evaluate blood glucose test results performed with four randomly selected glucometers on diabetes and control subjects versus standard wet chemistry (hexokinase) methods in Addis Ababa, Ethiopia. A prospective cross-sectional study was conducted on randomly selected 200 study participants (100 participants with diabetes and 100 healthy controls). Four randomly selected PoCG devices (CareSens N, DIAVUE Prudential, On Call Extra, i-QARE DS-W) were evaluated against hexokinase method and ISO 15197:2003 and ISO 15197:2013 standards. The minimum and maximum blood sugar values were recorded by CareSens N (21 mg/dl) and hexokinase method (498.8 mg/dl), respectively. The mean sugar values of all PoCG devices except On Call Extra showed significant differences compared with the reference hexokinase method. Meanwhile, all four PoCG devices had strong positive relationship (>80%) with the reference method (hexokinase). On the other hand, none of the four PoCG devices fulfilled the minimum accuracy measurement set by ISO 15197:2003 and ISO 15197:2013 standards. In addition, the linear regression analysis revealed that all four selected PoCG overestimated the glucose concentrations. The overall evaluation of the selected four PoCG measurements were poorly correlated with standard reference method. Therefore, before introducing PoCG devices to the market, there should be a standardized evaluation platform for validation. Further similar large-scale studies on other PoCG devices also need to be undertaken.
The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized
Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.
2016-01-01
Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID:27494336
Assessing the performance of handheld glucose testing for critical care.
Kost, Gerald J; Tran, Nam K; Louie, Richard F; Gentile, Nicole L; Abad, Victor J
2008-12-01
We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStriptrade mark, NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for > or =75 mg/dL, 100% were within tolerance. Paired differences (handheld minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r2 = 0.995. LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
Definition of a CDI metadata profile and its ISO 19139 based encoding
NASA Astrophysics Data System (ADS)
Boldrini, Enrico; de Korte, Arjen; Santoro, Mattia; Schaap, Dick M. A.; Nativi, Stefano; Manzella, Giuseppe
2010-05-01
The Common Data Index (CDI) is the middleware service adopted by SeaDataNet for discovery and query. The primary goal of the EU funded project SeaDataNet is to develop a system which provides transparent access to marine data sets and data products from 36 countries in and around Europe. The European context of SeaDataNet requires that the developed system complies with European Directive INSPIRE. In order to assure the required conformity a GI-cat based solution is proposed. GI-cat is a broker service able to mediate from different metadata sources and publish them through a consistent and unified interface. In this case GI-cat is used as a front end to the SeaDataNet portal publishing the original data, based on CDI v.1 XML schema, through an ISO 19139 application profile catalog interface (OGC CSW AP ISO). The choice of ISO 19139 is supported and driven by INSPIRE Implementing Rules, that have been used as a reference through the whole development process. A mapping from the CDI data model to the ISO 19139 was hence to be implemented in GI-cat and a first draft quickly developed, as both CDI v.1 and ISO 19139 happen to be XML implementations based on the same abstract data model (standard ISO 19115 - metadata about geographic information). This first draft mapping pointed out the CDI metadata model differences with respect to ISO 19115, as it was not possible to accommodate all the information contained in CDI v.1 into ISO 19139. Moreover some modifications were needed in order to reach INSPIRE compliance. The consequent work consisted in the definition of the CDI metadata model as a profile of ISO 19115. This included checking of all the metadata elements present in CDI and their cardinality. A comparison was made with respect to ISO 19115 and possible extensions were individuated. ISO 19139 was then chosen as a natural XML implementation of this new CDI metadata profile. The mapping and the profile definition processes were iteratively refined leading up to a complete mapping from the CDI data model to ISO 19139. Several issues were faced during the definition process. Among these: dynamic lists and vocabularies used by SeaDataNet could not be easily accommodated in ISO 19139, time resolution information from CDI v.1 was also difficult to accommodate, ambiguities both in the ISO 19139 specification and in the INSPIRE regulations (e.g. regarding to the bounding polygon, the language and the role of the responsible party). Another outcome of this process is the set up of conventions regarding the protocol formats to be used for a useful machine to machine data access. Changes to the original ISO 19139 schema were at the maximum extent avoided because of practical reasons within SeaDataNet: additional constraint required by the profile have been defined and will be checked by the use of Schematron or other validation mechanisms. The achieved mapping was finally ready to be integrated in GI-cat by implementation of a new accessor component for CDI. These type of components play the role of data model mediators within GI-cat framework. The new defined profile and its implementation will also be used within SeaDataNet as a replacement of the current data model implementation (CDI v.1).
Retail wheeling - users, utilities and power producers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kubacki, J. Jr.
1996-12-31
Information is outlined on the retail wheeling of electric power. Topics discussed include: SEL mission; average cost per kWh; retail pilot programs; retail wheeling activity; key tasks for industrials; power marketer quote; retail wheeling strategic planning; metered customer load profile; proposed ISO regions; conjunctive billing; interconnection areas; FERC order 888; open access same time information systems; transmission inferconnections; suppliers of energy and capacity; self-generation; FERC Form 714; rebundling unbundled services; key variables: load factor; energy and capacity; metering today; competitive industry configuration; power cost reduction: strategic planning; real-time pricing; prime sources of leverage; likeliness of switching utilities; and Strategic Energymore » Ltd.« less
Elsner, Jonathan J; Shemesh, Maoz; Shefy-Peleg, Adaya; Gabet, Yankel; Zylberberg, Eyal; Linder-Ganz, Eran
2015-09-01
A synthetic meniscus implant was recently developed for the treatment of patients with mild to moderate osteoarthritis with knee pain associated with medial joint overload. The implant is distinctively different from most orthopedic implants in its pliable construction, and non-anchored design, which enables implantation through a mini-arthrotomy without disruption to the bone, cartilage, and ligaments. Due to these features, it is important to show that the material and design can withstand knee joint conditions. This study evaluated the long-term performance of this device by simulating loading for a total of 5 million gait cycles (Mc), corresponding to approximately five years of service in-vivo. All five implants remained in good condition and did not dislodge from the joint space during the simulation. Mild abrasion was detected by electron microscopy, but µ-CT scans of the implants confirmed that the damage was confined to the superficial surfaces. The average gravimetric wear rate was 14.5 mg/Mc, whereas volumetric changes in reconstructed µ-CT scans point to an average wear rate of 15.76 mm(3)/Mc (18.8 mg/Mc). Particles isolated from the lubricant had average diameter of 15 µm. The wear performance of this polycarbonate-urethane meniscus implant concept under ISO-14243 loading conditions is encouraging. Copyright © 2015 Elsevier Ltd. All rights reserved.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins.
Steinmassl, Otto; Offermanns, Vincent; Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-03-08
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution.
In Vitro Analysis of the Fracture Resistance of CAD/CAM Denture Base Resins
Stöckl, Wolfgang; Dumfahrt, Herbert; Grunert, Ingrid
2018-01-01
Computer-aided design and computer-aided manufacturing (CAD/CAM) denture base manufacturers claim to produce their resin pucks under high heat and pressure. Therefore, CAD/CAM dentures are assumed to have enhanced mechanical properties and, as a result, are often produced with lower denture base thicknesses than conventional, manually fabricated dentures. The aim of this study was to investigate if commercially available CAD/CAM denture base resins have more favourable mechanical properties than conventionally processed denture base resins. For this purpose, a series of three-point bending tests conforming to ISO specifications were performed on a total of 80 standardised, rectangular CAD/CAM denture base resin specimens from five different manufacturers (AvaDent, Baltic Denture System, Vita VIONIC, Whole You Nexteeth, and Wieland Digital Dentures). A heat-polymerising resin and an autopolymerising resin served as the control groups. The breaking load, fracture toughness, and the elastic modulus were assessed. Additionally, the fracture surface roughness and texture were investigated. Only one CAD/CAM resin showed a significantly increased breaking load. Two CAD/CAM resins had a significantly higher fracture toughness than the control groups, and all CAD/CAM resins had higher elastic moduli than the controls. Our results indicate that CAD/CAM denture base resins do not generally have better mechanical properties than manually processed resins. Therefore, the lower minimum denture base thicknesses should be regarded with some caution. PMID:29518022
Ragher, Mallikarjuna; Vinayakumar, G; Patil, Sanketsopan; Chatterjee, Aishwarya; Mallikarjuna, D M; Dandekeri, Savita; Swetha, V; Pradeep, M R
2016-04-01
The objective of this study was to evaluate and compare changes in the flexural strength of heat-cured denture base resins when treated using denture cleansers. A total of 40 specimens with dimension 65 mm length, 10 mm width, and 3 mm thickness were prepared as per ISO 1567 specification. A total of 10 specimens were immersed in distilled water to be used as control. Of the remaining 30 samples, 10 were treated with Clinsodent, 10 with VI-Clean, and 10 with Clanden denture cleansers. Specimens in each group were subjected to three-point flexural load in universal testing machine at a cross-head speed of 5 mm/min. The peak load (N) was recorded and flexural strength was calculated. The findings were analyzed using Kruskal-Wallis analysis of variance and Mann-Whitney test. Heat-cured denture base resin selected for this study showed significant difference in flexural strength after immersion in denture cleansers Clinsodent, VI-Clean, and Clanden solutions, when compared with the control group. Findings of this study showed that denture cleansers altered the flexural strength of heat polymerized acrylic resins that endured soaking cycles which simulated 180 days of use. Hence, denture cleansers should be used with caution, once a day after brushing the dentures. It is advisable for patients to follow the manufacturer's instructions.
Gastro-protective effects of isobrucein B, a quassinoid isolated from Picrolemma sprucei.
Vieira, Sílvio Manfredo; Silva, Rangel Leal; Lemos, Henrique Paula; Amorim, Rodrigo César das Neves; Silva, Ellen Cristina Costa; Reinach, Peter Sol; Cunha, Fernando Queiróz; Pohlit, Adrian Martin; Cunha, Thiago Mattar
2014-06-01
Infusions of Picrolemma sprucei roots, stems and leaves are used in traditional medicine throughout the Amazon region from the Guianas to Brazil and Peru in the treatment of gastritis, intestinal helminths and malaria. As there are no studies describing its mode of action in providing a gastroprotective effect, we determined herein that one of the main constituents found in P. sprucei infusions, the quassinoid isobrucein B (IsoB), reduces some of the pathophysiological effects in a mouse model of non-steroidal anti-inflammatory drug (NSAID)-induced gastritis and provides mechanisms of action. Then, IsoB (1.17 g) was isolated from the roots and stems (6.5 kg) of P. sprucei. Its structure was confirmed by 1D and 2D (1)H and (13)C NMR, ESI-tof-MS, IR and UV. C57BL/6 strain mice were subcutaneously injected with IsoB (0.5-5 mg kg(-1)) or vehicle before oral administration of indomethacin and sacrificed later at different time points. Gastric damage was assessed by measuring lesion length. Leukocyte migration was evaluated based on leukocyte rolling and adhesion using intravital microscopy in the mesenteric microcirculation and tissue MPO activity. Stomach extract cytokine (TNFα, IL-1β and KC/CXCL1) and prostaglandin E2 (PGE2) levels were measured by ELISA and RIA, respectively. IsoB pre-treatment (0.5-5.0 mg kg(-1)) significantly reduced the formation of indomethacin-induced stomach lesions in a dose-dependent manner. The decrease in stomach lesions was associated with less observed leukocyte rolling, decreased leukocyte adhesion and less neutrophil infiltration (MPO activity). IsoB (1 mg kg(-1)) pre-treatment did not prevent indomethacin-induced decreases in stomach PGE2 levels. However, IL-1β and KC/CXCL1 levels were inhibited by this same IsoB dosage, whereas TNF-α was unchanged. IsoB may be a prototypic compound to provide protective effects against NSAID-induced gastritis and possibly other gastropathies. Moreover, IsoB gastroprotective action may be due to a reduction in IL-1β and KC/CXCL1 production/release and leukocyte rolling, adhesion and migration. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H
Purpose: To evaluate the dosimetric metrics of HDR Ring and Tandem applicator Brachytherapy for primary cervical cancers. Methods: The dosimetric metrics of high-risk clinical target volumes (HDR-CTV) of 12 patients (in total 60 fractions/plans) treated with the HDR ring and tandem applicators were retrospectively analyzed. Ring diameter is from 2.6 to 3.4 cm, tandem length is from 4 to 6 cm, and the angle is either 45 or 60 degrees. The first fraction plan was MR guided, the MR images were then used as a reference for contouring the HR-CTV in CT images of following 4 fractions. The nominal prescriptionmore » dose was between 5.2 and 5.8 Gy at the point A. The plans were adjusted to cover at least 90% of the HR-CTV by 90% of the prescription dose and to reduce the doses to the bladder, rectum and bowel-bag. Minimum target dose of D100 and D90 were converted into the biologically equivalent EBRT dose D90-iso and D100-iso (using α/β=10 Gy, 2 Gy/fx). Equivalent uniform doses (EUD) based on the average cancer killing across the target volume were calculated by the modified linear quadratic model (MLQ) from the differential dose volume histogram (DVH) tables. Results: The average D90iso of all plans is 8.1 Gy (ranging from 6.2 to 15 Gy, median 7.8 Gy); the average D100iso is just 4.1 Gy (ranging from 1.8 to 7.8 Gy; median 3.9 Gy). The average EUD is 7.0 Gy (ranging from 6.1 to 9.6 Gy, median 6.9 Gy), which is 87% of the D90iso, and 170% of the D100iso. Conclusion: The EUDs is smaller than D90iso but greater than D100iso. Because the EUD takes into account the intensive cancer cell killing in the high dose zone of HR-CTV, MLQ calculated EUD apparently is more relevant than D90 and D100 to describe the HDR brachytherapy treatment quality.« less
Ether- and Ester-Bound iso-Diabolic Acid and Other Lipids in Members of Acidobacteria Subdivision 4
Rijpstra, W. Irene C.; Hopmans, Ellen C.; Foesel, Bärbel U.; Wüst, Pia K.; Overmann, Jörg; Tank, Marcus; Bryant, Donald A.; Dunfield, Peter F.; Houghton, Karen; Stott, Matthew B.
2014-01-01
Recently, iso-diabolic acid (13,16-dimethyl octacosanedioic acid) has been identified as a major membrane-spanning lipid of subdivisions 1 and 3 of the Acidobacteria, a highly diverse phylum within the Bacteria. This finding pointed to the Acidobacteria as a potential source for the bacterial glycerol dialkyl glycerol tetraethers that occur ubiquitously in peat, soil, lakes, and hot springs. Here, we examined the lipid composition of seven phylogenetically divergent strains of subdivision 4 of the Acidobacteria, a bacterial group that is commonly encountered in soil. Acid hydrolysis of total cell material released iso-diabolic acid derivatives in substantial quantities (11 to 48% of all fatty acids). In contrast to subdivisions 1 and 3 of the Acidobacteria, 6 out of the 7 species of subdivision 4 (excepting “Candidatus Chloracidobacterium thermophilum”) contained iso-diabolic acid ether bound to a glycerol in larger fractional abundance than iso-diabolic acid itself. This is in agreement with the analysis of intact polar lipids (IPLs) by high-performance liquid chromatography-mass spectrometry (HPLC-MS), which showed the dominance of mixed ether-ester glycerides. iso-Diabolic acid-containing IPLs were not identified, because these IPLs are not released with a Bligh-Dyer extraction, as observed before when studying lipid compositions of subdivisions 1 and 3 of the Acidobacteria. The presence of ether bonds in the membrane lipids does not seem to be an adaptation to temperature, because the five mesophilic isolates contained a larger amount of ether lipids than the thermophile “Ca. Chloracidobacterium thermophilum.” Furthermore, experiments with Pyrinomonas methylaliphatogenes did not reveal a major influence of growth temperature over the 50 to 69°C range. PMID:24928878
A Load-Based Temperature Prediction Model for Anomaly Detection
NASA Astrophysics Data System (ADS)
Sobhani, Masoud
Electric load forecasting, as a basic requirement for the decision-making in power utilities, has been improved in various aspects in the past decades. Many factors may affect the accuracy of the load forecasts, such as data quality, goodness of the underlying model and load composition. Due to the strong correlation between the input variables (e.g., weather and calendar variables) and the load, the quality of input data plays a vital role in forecasting practices. Even if the forecasting model were able to capture most of the salient features of the load, a low quality input data may result in inaccurate forecasts. Most of the data cleansing efforts in the load forecasting literature have been devoted to the load data. Few studies focused on weather data cleansing for load forecasting. This research proposes an anomaly detection method for the temperature data. The method consists of two components: a load-based temperature prediction model and a detection technique. The effectiveness of the proposed method is demonstrated through two case studies: one based on the data from the Global Energy Forecasting Competition 2014, and the other based on the data published by ISO New England. The results show that by removing the detected observations from the original input data, the final load forecast accuracy is enhanced.
Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.
Eypert-Blaison, Celine; Veissiere, Sylvie; Rastoix, Olivier; Kauffer, Edmond
2010-01-01
Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.
Application of a risk management system to improve drinking water safety.
Jayaratne, Asoka
2008-12-01
The use of a comprehensive risk management framework is considered a very effective means of managing water quality risks. There are many risk-based systems available to water utilities such as ISO 9001 and Hazard Analysis and Critical Control Point (HACCP). In 2004, the World Health Organization's (WHO) Guidelines for Drinking Water Quality recommended the use of preventive risk management approaches to manage water quality risks. This paper describes the framework adopted by Yarra Valley Water for the development of its Drinking Water Quality Risk Management Plan incorporating HACCP and ISO 9001 systems and demonstrates benefits of Water Safety Plans such as HACCP. Copyright IWA Publishing 2008.
NASA Astrophysics Data System (ADS)
Hosseini-Bioki, M. M.; Rashidinejad, M.; Abdollahi, A.
2013-11-01
Load shedding is a crucial issue in power systems especially under restructured electricity environment. Market-driven load shedding in reregulated power systems associated with security as well as reliability is investigated in this paper. A technoeconomic multi-objective function is introduced to reveal an optimal load shedding scheme considering maximum social welfare. The proposed optimization problem includes maximum GENCOs and loads' profits as well as maximum loadability limit under normal and contingency conditions. Particle swarm optimization (PSO) as a heuristic optimization technique, is utilized to find an optimal load shedding scheme. In a market-driven structure, generators offer their bidding blocks while the dispatchable loads will bid their price-responsive demands. An independent system operator (ISO) derives a market clearing price (MCP) while rescheduling the amount of generating power in both pre-contingency and post-contingency conditions. The proposed methodology is developed on a 3-bus system and then is applied to a modified IEEE 30-bus test system. The obtained results show the effectiveness of the proposed methodology in implementing the optimal load shedding satisfying social welfare by maintaining voltage stability margin (VSM) through technoeconomic analyses.
NASA Astrophysics Data System (ADS)
Ramadhan, A.; Fathurrohman, M. Irfan; Falaah, A. F.; Setyawan, N.; Soegijono, B.
2017-07-01
The interlayer basal spacing of organoclay (OC) could be increased with stearic acid (SA) added, thus OC changed into expanded organoclay by SA (OCSA). The effect of various loadings of OCSA on the curing, mechanical and swelling properties of natural rubber (NR) nanocomposites were studied. The natural rubber/expanded organoclay (NR/OCSA) nanocomposites were prepared by melt intercalation using a laboratory open mill. The curing characteristics of NR compounds were determined using a Moving Die Rheometer (MDR). The X-ray Diffraction (XRD), Attenuated Total Reflectance Infrared (ATR-IR) Spectroscopy and Field Emission Scanning Electron Microscopy (FESEM) were used to study the dispersion of OCSA in the NR matrix. The mechanical properties of NR/OCSA nanocomposites such as tensile strength, elongation at break and hardness were determined using ISO standard and swelling of NR/OCSA nanocomposites in toluene were determined using ISO 1817. The results showed that the SA intercalated into the gallery of OC and reacted with the hydroxyl groups in OC. It was indicated with the shifting of the negative peak 1,700 to 1,723 cm-1 in the ATR-IR spectrum and increase the d-spacing of OC. The adding of various loadings of OCSA into NR could increase the torque and accelerate the curing of nanocomposites and it also could increase the mechanical and swelling properties of nanocomposites. The change in modulus at 100% elongation significantly increased with increasing the OCSA load until maximum loading at 10 phr. This trend was same with the hardness and modulus at 300% elongation. Meanwhile, the improvement of tensile strength and elongation at break was higher at 4 phr OCSA compared with the other loading. The increase of mechanical and swelling properties of NR/OCSA nanocomposites was due to intercalation/exfoliation of OCSA in NR matrix. It was revealed by appearing of the out-of-plane Si-O-(Al) stretch with peak value 1080 cm-1 in the ATR-IR spectrum and the peaks of OCSA in the XRD pattern was disappeared until the loading of OCSA 8 phr and the thickness of morphology of OCSA below 100 nm.
2016-04-01
Gerard Chaney, and Charles Pergantis Weapons and Materials Research Directorate, ARL Coatings, Corrosion, and Engineered Polymers Branch (CCEPB...SUBJECT TERMS single lap joint, adhesive, sample preparation, testing, database, metadata, material pedigree, ISO 16. SECURITY CLASSIFICATION OF: 17...temperature/water immersion conditioning test for lap-joint test specimens using the test tubes and convection oven method
The Structural Formation and Physical Behaviour of Cross-Linked Epoxy Resins
1981-04-01
analysis , at which the heat evolution reaches a maximum, may be used for purposes of characterisation. Aliphatic polyamines react mere quickly than the...DTA, DSC), thermomechanical analysis (TMA), torsional vibration analysis (TVA), deter- mination of the dimensional stability under heat (eq ISO R 75 or...obtained by thermomechanical analysis , taking the temperature of maximum velocity of penetration of a loaded probe (rate of heating - 10°C/min
Choi, Jaeyeon; Vaidyanathan, Ganesan; Koumarianou, Eftychia; McDougald, Darryl; Pruszynski, Marek; Osada, Takuya; Lahoutte, Tony; Lyerly, H. Kim; Zalutsky, Michael R.
2014-01-01
Introduction N-succinimidyl 4-guanidinomethyl-3-[*I]iodobenzoate ([*I]SGMIB) has shown promise for the radioiodination of monoclonal antibodies (mAbs) and other proteins that undergo extensive internalization after receptor binding, enhancing tumor targeting compared to direct electrophilic radioiodination. However, radiochemical yields for [131I]SGMIB synthesis are low, which we hypothesize is due to steric hindrance from the Boc-protected guanidinomethyl group ortho to the tin moiety. To overcome this, we developed the isomeric compound, N-succinimidyl 3-guanidinomethyl-5-[131I]iodobenzoate (iso-[131I]SGMIB) wherein this bulky group was moved from ortho to meta position. Methods Boc2-iso-SGMIB standard and its tin precursor, N-succinimidyl 3-((1,2-bis(tert-butoxycarbonyl)guanidino)methyl)-5-(trimethylstannyl)benzoate (Boc2-iso-SGMTB), were synthesized using two disparate routes, and iso-[*I]SGMIB synthesized from the tin precursor. Two HER2-targeted vectors — trastuzumab (Tras) and a nanobody 5F7 (Nb) — were labeled using iso-[*I]SGMIB and [*I]SGMIB. Paired-label internalization assays in vitro with both proteins, and biodistribution in vivo with trastuzumab, labeled using the two isomeric prosthetic agents were performed. Results When the reactions were performed under identical conditions, radioiodination yields for the synthesis of Boc2-iso-[131I]SGMIB were significantly higher than those for Boc2-[131I]SGMIB (70.7 ± 2.0% vs 56.5 ± 5.5%). With both Nb and trastuzumab, conjugation efficiency also was higher with iso-[131I]SGMIB than with [131I]SGMIB (Nb, 33.1 ± 7.1% vs 28.9 ± 13.0%; Tras, 45.1 ± 4.5% vs 34.8 ± 10.3%); however, the differences were not statistically significant. Internalization assays performed on BT474 cells with 5F7 Nb indicated similar residualizing capacity over 6 h; however, at 24 h, radioactivity retained intracellularly for iso-[131I]SGMIB-Nb was lower than for [125I]SGMIB-Nb (46.4 ± 1.3% vs 56.5 ± 2.5%); similar results were obtained using Tras. Likewise, a paired-label biodistribution of Tras labeled using iso-[125I]SGMIB and [131I]SGMIB indicated an up to 22% tumor uptake advantage at later time points for [131I]SGMIB-Tras. Conclusion Given the higher labeling efficiency obtained with iso-SGMIB, this residualizing agent might be of value for use with shorter half-life radiohalogens. PMID:25156548
Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.
Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José
2010-11-01
The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.
Fracture toughness versus micro-tensile bond strength testing of adhesive-dentin interfaces.
De Munck, Jan; Luehrs, Anne-Katrin; Poitevin, André; Van Ende, Annelies; Van Meerbeek, Bart
2013-06-01
To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (μTBS) test. Chevron-notched beam fracture toughness (CNB) was measured following a modified ISO 24370 standard. Composite bars with dimensions of 3.0×4.0×25 mm were prepared, with the adhesive-dentin interface in the middle. At the adhesive-dentin interface, a chevron notch was prepared using a 0.15 mm thin diamond blade mounted in a water-cooled diamond saw. Each specimen was loaded until failure in a 4-point bend test setup and the fracture toughness was calculated according to the ISO specifications. Similarly, adhesive-dentin micro-specimens (1.0×1.0×8-10 mm) were stressed in tensile until failure to determine the μTBS. A positive correlation (r(2)=0.64) was observed between CNB and μTBS, which however was only nearly statistically significant, mainly due to the dissimilar outcome of Scotchbond Universal (3M ESPE). While few μTBS specimens failed at the adhesive-dentin interface, almost all CNB specimens failed interfacially at the notch tip. Weibull moduli for interfacial fracture toughness were much higher than for μTBS (3.8-11.5 versus 2.7-4.8, respectively), especially relevant with regard to early failures. Although the ranking of the adhesives on their bonding effectiveness tested using CNB and μTBS corresponded well, the outcome of CNB appeared more reliable and less variable. Fracture toughness measurement is however more laborious and requires specific equipment. The μTBS nevertheless appeared to remain a valid method to assess bonding effectiveness in a versatile way. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Clinical evaluation of the FreeStyle Precision Pro system.
Brazg, Ronald; Hughes, Kristen; Martin, Pamela; Coard, Julie; Toffaletti, John; McDonnell, Elizabeth; Taylor, Elizabeth; Farrell, Lausanne; Patel, Mona; Ward, Jeanne; Chen, Ting; Alva, Shridhara; Ng, Ronald
2013-06-05
A new version of international standard (ISO 15197) and CLSI Guideline (POCT12) with more stringent accuracy criteria are near publication. We evaluated the glucose test performance of the FreeStyle Precision Pro system, a new blood glucose monitoring system (BGMS) designed to enhance accuracy for point-of-care testing (POCT). Precision, interference and system accuracy with 503 blood samples from capillary, venous and arterial sources were evaluated in a multicenter study. Study results were analyzed and presented in accordance with the specifications and recommendations of the final draft ISO 15197 and the new POCT12. The FreeStyle Precision Pro system demonstrated acceptable precision (CV <5%), no interference across a hematocrit range of 15-65%, and, except for xylose, no interference from 24 of 25 potentially interfering substances. It also met all accuracy criteria specified in the final draft ISO 15197 and POCT12, with 97.3-98.9% of the individual results of various blood sample types agreeing within ±12 mg/dl of the laboratory analyzer values at glucose concentrations <100mg/dl and within ±12.5% of the laboratory analyzer values at glucose concentrations ≥100 mg/dl. The FreeStyle Precision Pro system met the tighter accuracy requirements, providing a means for enhancing accuracy for point-of-care blood glucose monitoring. Copyright © 2013 Elsevier B.V. All rights reserved.
Rolland-Debord, Camille; Morelot-Panzini, Capucine; Similowski, Thomas; Duranti, Roberto; Laveneziana, Pierantonio
2017-12-01
Exercise induces release of cytokines and increase of circulating natural killers (NK) lymphocyte during strong activation of respiratory muscles. We hypothesised that non-fatiguing respiratory muscle loading during exercise causes an increase in NK cells and in metabolic stress indices. Heart rate (HR), ventilation (VE), oesophageal pressure (Pes), oxygen consumption (VO 2 ), dyspnoea and leg effort were measured in eight healthy humans (five men and three women, average age of 31 ± 4 years and body weight of 68 ± 10 kg), performing an incremental exercise testing on a cycle ergometer under control condition and expiratory flow limitation (FL) achieved by putting a Starling resistor. Blood samples were obtained at baseline, at peak of exercise and at iso-workload corresponding to that reached at the peak of FL exercise during control exercise. Diaphragmatic fatigue was evaluated by measuring the tension time index of the diaphragm. Respiratory muscle overloading caused an earlier interruption of exercise. Diaphragmatic fatigue did not occur in the two conditions. At peak of flow-limited exercise compared to iso-workload, HR, peak inspiratory and expiratory Pes, NK cells and norepinephrine were significantly higher. The number of NK cells was significantly related to ΔPes (i.e. difference between the most and the less negative Pes) and plasmatic catecholamines. Loading of respiratory muscles is able to cause an increase of NK cells provided that activation of respiratory muscles is intense enough to induce a significant metabolic stress.
Deformation and Heat Transfer on Three Sides Protected Beams under Fire Accident
NASA Astrophysics Data System (ADS)
Imran, M.; Liew, M. S.; Garcia, E. M.; Nasif, M. S.; Yassin, A. Y. M.; Niazi, U. M.
2018-04-01
Fire accidents are common in oil and gas industry. The application of passive fire protection (PFP) is a costly solution. The PFP is applied only on critical structural members to optimise project cost. In some cases, beams cannot be protected from the top flange in order to accommodate for the placement of pipe supports and grating. It is important to understand the thermal and mechanical response of beam under such condition. This paper discusses the response of steel beam under ISO 834 fire protected, unprotected and three sides protected beams. The model validated against an experimental study. The experimental study has shown good agreement with FE model. The study revealed that the beams protected from three sides heat-up faster compare to fully protected beam showing different temperature gradient. However, the affects load carrying capacity are insignificant under ISO 834 fire.
Impact of daily mood, work hours, and iso-strain variables on self-reported health behaviors.
Jones, Fiona; O'Connor, Daryl B; Conner, Mark; McMillan, Brian; Ferguson, Eamonn
2007-11-01
Four hundred and twenty-two employees completed daily diaries measuring positive affect, negative affect, work hours, and health behaviors (snacking, smoking, exercise, alcohol, caffeine consumption) on work days over a 4-week period. In addition, measures of job demands, job control, and social support (iso-strain variables) were completed on 1 occasion. Multilevel random coefficient modeling was used to examine relationships between the job characteristics, daily work variables, and self-reported health behaviors. Results indicated a more important role for within-person daily fluctuations than for between-persons variations in predicting health behaviors. Whereas negative affect was negatively related to health behavior for both men and women, work hours had negative impacts for women only. Iso-strain variables showed few main effects and a modest number of interactions with daily variables (mainly for men). Findings point to the limited impact of stable features of work design compared to the effects of daily work stressors on health behaviors. (c) 2007 APA
Packet Traffic Dynamics Near Onset of Congestion in Data Communication Network Model
NASA Astrophysics Data System (ADS)
Lawniczak, A. T.; Tang, X.
2006-05-01
The dominant technology of data communication networks is the Packet Switching Network (PSN). It is a complex technology organized as various hierarchical layers according to the International Standard Organization (ISO) Open Systems Interconnect (OSI) Reference Model. The Network Layer of the ISO OSI Reference Model is responsible for delivering packets from their sources to their destinations and for dealing with congestion if it arises in a network. Thus, we focus on this layer and present an abstraction of the Network Layer of the ISO OSI Reference Model. Using this abstraction we investigate how onset of traffic congestion is affected for various routing algorithms by changes in network connection topology. We study how aggregate measures of network performance depend on network connection topology and routing. We explore packets traffic spatio-temporal dynamics near the phase transition point from free flow to congestion for various network connection topologies and routing algorithms. We consider static and adaptive routings. We present selected simulation results.
NASA Astrophysics Data System (ADS)
Hanumagowda, B. N.; Savitramma, G.; Salma, A.; Noorjahan
2018-04-01
In this article, the theoretical analysis of the combined study of non-Newtonian couple stresses with piezo-viscous dependency for annular plates squeeze film bearings have been carried out, with help of stokes micro continuum theory along with the exponential variation of viscosity with pressure. An approximate analytical solution is found using a small perturbation method. The solution for pressure and load capacity with distinct values of viscosity-pressure parameter are calculated and compared with iso-viscous couple stress and Newtonian lubricants and the results reveals that the effect of couple stresses and pressure-dependent viscosity variation enhances the load-carrying capacity and lengthens the squeeze film time.
USDA-ARS?s Scientific Manuscript database
Low stability at high salt concentrations, iso-electric point, and high temperature restricted the application of proteins as stabilizers in nutraceutical encapsulation. Protein-polysaccharide conjugates made with Maillard reaction may be better alternatives. In this study, the characteristics of cu...
Numerical and experimental validation for the thermal transmittance of windows with cellular shades
Hart, Robert
2018-02-21
Some highly energy efficient window attachment products are available today, but more rapid market adoption would be facilitated by fair performance metrics. It is important to have validated simulation tools to provide a basis for this analysis. This paper outlines a review and validation of the ISO 15099 center-of-glass zero-solar-load heat transfer correlations for windows with cellular shades. Thermal transmittance was measured experimentally, simulated using computational fluid dynamics (CFD) analysis, and simulated utilizing correlations from ISO 15099 as implemented in Berkeley Lab WINDOW and THERM software. CFD analysis showed ISO 15099 underestimates heat flux of rectangular cavities by up tomore » 60% when aspect ratio (AR) = 1 and overestimates heat flux up to 20% when AR = 0.5. CFD analysis also showed that wave-type surfaces of cellular shades have less than 2% impact on heat flux through the cavities and less than 5% for natural convection of room-side surface. WINDOW was shown to accurately represent heat flux of the measured configurations to a mean relative error of 0.5% and standard deviation of 3.8%. Finally, several shade parameters showed significant influence on correlation accuracy, including distance between shade and glass, inconsistency in cell stretch, size of perimeter gaps, and the mounting hardware.« less
Numerical and experimental validation for the thermal transmittance of windows with cellular shades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Robert
Some highly energy efficient window attachment products are available today, but more rapid market adoption would be facilitated by fair performance metrics. It is important to have validated simulation tools to provide a basis for this analysis. This paper outlines a review and validation of the ISO 15099 center-of-glass zero-solar-load heat transfer correlations for windows with cellular shades. Thermal transmittance was measured experimentally, simulated using computational fluid dynamics (CFD) analysis, and simulated utilizing correlations from ISO 15099 as implemented in Berkeley Lab WINDOW and THERM software. CFD analysis showed ISO 15099 underestimates heat flux of rectangular cavities by up tomore » 60% when aspect ratio (AR) = 1 and overestimates heat flux up to 20% when AR = 0.5. CFD analysis also showed that wave-type surfaces of cellular shades have less than 2% impact on heat flux through the cavities and less than 5% for natural convection of room-side surface. WINDOW was shown to accurately represent heat flux of the measured configurations to a mean relative error of 0.5% and standard deviation of 3.8%. Finally, several shade parameters showed significant influence on correlation accuracy, including distance between shade and glass, inconsistency in cell stretch, size of perimeter gaps, and the mounting hardware.« less
NASA Astrophysics Data System (ADS)
Duffy, Alan; Yates, Brian; Takacs, Peter
2012-09-01
The Optical Metrology Facility at the Canadian Light Source (CLS) has recently purchased MountainsMap surface analysis software from Digital Surf and we report here our experiences with this package and its usefulness as a tool for examining metrology data of synchrotron x-ray mirrors. The package has a number of operators that are useful for determining surface roughness and slope error including compliance with ISO standards (viz. ISO 4287 and ISO 25178). The software is extensible with MATLAB scripts either by loading an m-file or by a user written script. This makes it possible to apply a custom operator to measurement data sets. Using this feature we have applied the simple six-line MATLAB code for the direct least square fitting of ellipses developed by Fitzgibbon et. al. to investigate the residual slope error of elliptical mirrors upon the removal of the best-fit-ellipse. The software includes support for many instruments (e.g. Zygo, MicroMap, etc...) and can import ASCII data (e.g. LTP data). The stitching module allows the user to assemble overlapping images and we report on our experiences with this feature applied to MicroMap surface roughness data. The power spectral density function was determined for the stitched and unstitched data and compared.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makoto Kashiwagi; Garamszeghy, Mike; Lantes, Bertrand
Disposal of low-and intermediate-level activated waste generated at nuclear power plants is being planned or carried out in many countries. The radioactivity concentrations and/or total quantities of long-lived, difficult-to-measure nuclides (DTM nuclides), such as C-14, Ni-63, Nb-94, α emitting nuclides etc., are often restricted by the safety case for a final repository as determined by each country's safety regulations, and these concentrations or amounts are required to be known and declared. With respect to waste contaminated by contact with process water, the Scaling Factor method (SF method), which is empirically based on sampling and analysis data, has been applied asmore » an important method for determining concentrations of DTM nuclides. This method was standardized by the International Organization for Standardization (ISO) and published in 2007 as ISO21238 'Scaling factor method to determine the radioactivity of low and intermediate-level radioactive waste packages generated at nuclear power plants' [1]. However, for activated metal waste with comparatively high concentrations of radioactivity, such as may be found in reactor control rods and internal structures, direct sampling and radiochemical analysis methods to evaluate the DTM nuclides are limited by access to the material and potentially high personnel radiation exposure. In this case, theoretical calculation methods in combination with empirical methods based on remote radiation surveys need to be used to best advantage for determining the disposal inventory of DTM nuclides while minimizing exposure to radiation workers. Pursuant to this objective a standard for the theoretical evaluation of the radioactivity concentration of DTM nuclides in activated waste, is in process through ISO TC85/SC5 (ISO Technical Committee 85: Nuclear energy, nuclear technologies, and radiological protection; Subcommittee 5: Nuclear fuel cycle). The project team for this ISO standard was formed in 2011 and is composed of experts from 11 countries. The project team has been conducting technical discussions on theoretical methods for determining concentrations of radioactivity, and has developed the draft International Standard of ISO16966 'Theoretical activation calculation method to evaluate the radioactivity of activated waste generated at nuclear reactors' [2]. This paper describes the international standardization process developed by the ISO project team, and outlines the following two theoretical activity evaluation methods:? Point method? Range method. (authors)« less
Piacentino, V; Dipla, K; Gaughan, J P; Houser, S R
2000-03-15
1. Direct voltage-gated (voltage-dependent Ca2+ release, VDCR) and Ca2+ influx-gated (Ca2+-induced Ca2+ release, CICR) sarcoplasmic reticulum (SR) Ca2+ release were studied in feline ventricular myocytes. The voltage-contraction relationship predicted by the VDCR hypothesis is sigmoidal with large contractions at potentials near the Ca2+ equilibrium potential (ECa). The relationship predicted by the CICR hypothesis is bell-shaped with no contraction at ECa. 2. The voltage dependence of contraction was measured in ventricular myocytes at physiological temperature (37 C), resting membrane potential and physiological [K+]. Experiments were performed with cyclic adenosine 3',5'-monophosphate (cAMP) in the pipette or in the presence of the beta-adrenergic agonist isoproterenol (isoprenaline; ISO). 3. The voltage-contraction relationship was bell-shaped in Na+-free solutions (to eliminate the Na+ current and Na+-Ca2+ exchange, NCX) but the relationship was broader than the L-type Ca2+ current (ICa,L)-voltage relationship. 4. Contractions induced with voltage steps from normal resting potentials to -40 mV are thought to represent VDCR rather than CICR. We found that cAMP and ISO shifted the voltage dependence of ICa,L activation to more negative potentials so that ICa,L was always present with steps to -40 mV. ICa,L at -40 mV inactivated when the holding potential was decreased (VŁ = -57.8 +/- 0.49 mV). 5. ISO increased inward current, SR Ca2+ load and contraction in physiological [Na+] and a broad bell-shaped voltage-contraction relationship was observed. Inhibition of reverse-mode NCX, decreasing ICa,L and decreasing SR Ca2+ loading all decreased contractions at strongly positive potentials near ECa. 6. The voltage-contraction relationship in 200 microM cadmium (Cd2+) was bell-shaped, supporting a role of ICa,L rather than VDCR. 7. All results could be accounted for by the CICR hypothesis, and many results exclude the VDCR hypothesis.
Baur, Daniel A.; Vargas, Fernanda de C. S.; Bach, Christopher W.; Garvey, Jordan A.; Ormsbee, Michael J.
2016-01-01
While prior research reported altered fuel utilization stemming from pre-exercise modified starch ingestion, the practical value of this starch for endurance athletes who consume carbohydrates both before and during exercise is yet to be examined. The purpose of this study was to determine the effects of ingesting a hydrothermally-modified starch supplement (HMS) before and during cycling on performance, metabolism, and gastrointestinal comfort. In a crossover design, 10 male cyclists underwent three nutritional interventions: (1) a commercially available sucrose/glucose supplement (G) 30 min before (60 g carbohydrate) and every 15 min during exercise (60 g∙h−1); (2) HMS consumed at the same time points before and during exercise in isocaloric amounts to G (Iso HMS); and (3) HMS 30 min before (60 g carbohydrate) and every 60 min during exercise (30 g·h−1; Low HMS). The exercise protocol (~3 h) consisted of 1 h at 50% Wmax, 8 × 2-min intervals at 80% Wmax, and 10 maximal sprints. There were no differences in sprint performance with Iso HMS vs. G, while both G and Iso HMS likely resulted in small performance enhancements (5.0%; 90% confidence interval = ±5.3% and 4.4%; ±3.2%, respectively) relative to Low HMS. Iso HMS and Low HMS enhanced fat oxidation (31.6%; ±20.1%; very likely (Iso); 20.9%; ±16.1%; likely (Low), and reduced carbohydrate oxidation (−19.2%; ±7.6%; most likely; −22.1%; ±12.9%; very likely) during exercise relative to G. However, nausea was increased during repeated sprints with ingestion of Iso HMS (17 scale units; ±18; likely) and Low HMS (18; ±14; likely) vs. G. Covariate analysis revealed that gastrointestinal distress was associated with reductions in performance with Low HMS vs. G (likely), but this relationship was unclear with Iso HMS vs. G. In conclusion, pre- and during-exercise ingestion of HMS increases fat oxidation relative to G. However, changes do not translate to performance improvements, possibly owing to HMS-associated increases in gastrointestinal distress, which is not attenuated by reducing the intake rate of HMS during exercise. PMID:27347999
Baur, Daniel A; Vargas, Fernanda de C S; Bach, Christopher W; Garvey, Jordan A; Ormsbee, Michael J
2016-06-25
While prior research reported altered fuel utilization stemming from pre-exercise modified starch ingestion, the practical value of this starch for endurance athletes who consume carbohydrates both before and during exercise is yet to be examined. The purpose of this study was to determine the effects of ingesting a hydrothermally-modified starch supplement (HMS) before and during cycling on performance, metabolism, and gastrointestinal comfort. In a crossover design, 10 male cyclists underwent three nutritional interventions: (1) a commercially available sucrose/glucose supplement (G) 30 min before (60 g carbohydrate) and every 15 min during exercise (60 g∙h(-1)); (2) HMS consumed at the same time points before and during exercise in isocaloric amounts to G (Iso HMS); and (3) HMS 30 min before (60 g carbohydrate) and every 60 min during exercise (30 g·h(-1); Low HMS). The exercise protocol (~3 h) consisted of 1 h at 50% Wmax, 8 × 2-min intervals at 80% Wmax, and 10 maximal sprints. There were no differences in sprint performance with Iso HMS vs. G, while both G and Iso HMS likely resulted in small performance enhancements (5.0%; 90% confidence interval = ±5.3% and 4.4%; ±3.2%, respectively) relative to Low HMS. Iso HMS and Low HMS enhanced fat oxidation (31.6%; ±20.1%; very likely (Iso); 20.9%; ±16.1%; likely (Low), and reduced carbohydrate oxidation (-19.2%; ±7.6%; most likely; -22.1%; ±12.9%; very likely) during exercise relative to G. However, nausea was increased during repeated sprints with ingestion of Iso HMS (17 scale units; ±18; likely) and Low HMS (18; ±14; likely) vs. G. Covariate analysis revealed that gastrointestinal distress was associated with reductions in performance with Low HMS vs. G (likely), but this relationship was unclear with Iso HMS vs. G. In conclusion, pre- and during-exercise ingestion of HMS increases fat oxidation relative to G. However, changes do not translate to performance improvements, possibly owing to HMS-associated increases in gastrointestinal distress, which is not attenuated by reducing the intake rate of HMS during exercise.
Tong, Yanhong; McCarthy, Kaitlin; Kong, Huimin; Lemieux, Bertrand
2013-01-01
We have developed a rapid and simple molecular test, the IsoGlow HSV Typing assay, for the detection and typing of herpes simplex virus (type 1 and 2) from genital or oral lesions. Clinical samples suspended in viral transport mediums are simply diluted and then added to a helicase-dependent amplification master mix. The amplification and detection were performed on a portable fluorescence detector called the FireFly instrument. Detection of amplification products is based on end-point analysis using cycling probe technology. An internal control nucleic acid was included in the amplification master mix to monitor the presence of amplification inhibitors in the samples. Because the device has only two fluorescence detection channels, two strategies were developed and compared to detect the internal control template: internal control detected by melting curve analysis using a dual-labeled probe, versus internal control detection using end-point fluorescence release by a CPT probe at a lower temperature. Both have a total turnaround time of about 1 hour. Clinical performance relative to herpes viral culture was evaluated using 176 clinical specimens. Both formats of the IsoGlow HSV typing assay had sensitivities comparable to that of the Food and Drug Administration–cleared IsoAmp HSV (BioHelix Corp., Beverly MA) test and specificity for the two types of HSV comparable to that of ELVIS HSV (Diagnostic Hybrids, Athens, OH). PMID:22951487
Acoustic emission analysis of fiber-reinforced composite in flexural testing.
Alander, Pasi; Lassila, Lippo V J; Tezvergil, Arzu; Vallittu, Pekka K
2004-05-01
The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.
Characterization of the Minimum Energy Paths for the Ring Closure Reactions of C4H3 with Acetylene
NASA Technical Reports Server (NTRS)
Walch, Stephen P.
1995-01-01
The ring closure reaction of C4H3 with acetylene to give phenyl radical is one proposed mechanism for the formation of the first aromatic ring in hydrocarbon combustion. There are two low-lying isomers of C4H3; 1-dehydro-buta-l-ene-3-yne (n-C4H3) and 2-dehydro-buta-l-ene-3-yne (iso-C4H3). It has been proposed that only n-C4H3 reacts with acetylene to give phenyl radical, and since iso-C4H3 is more stable than n-C4H3, formation of phenyl radical by this mechanism is unlikely. We report restricted Hartree-Fock (RHF) plus singles and doubles configuration interaction calculations with a Davidson's correction (RHF+1+2+Q) using the Dunning correlation consistent polarized valence double zeta basis set (cc-pVDZ) for stationary point structures along the reaction pathway for the reactions of n-C4H3 and iso-C4H3 with acetylene. n-C4H3 plus acetylene (9.4) has a small entrance channel barrier (17.7) (all energetics in parentheses are in kcal/mol with respect to iso-C4H3 plus acetylene) and the subsequent closure steps leading to phenyl radical (-91.9) are downhill with respect to the entrance channel barrier. Iso-C4H3 Plus acetylene also has an entrance channel barrier (14.9) and there is a downhill pathway to 1-dehydro-fulvene (-55.0). 1-dehydro-fulvene can rearrange to 6-dehydro-fulvene (-60.3) by a 1,3-hydrogen shift over a barrier (4.0), which is still below the entrance channel barrier, from which rearrangement to phenyl radical can occur by a downhill pathway. Thus, both n-C4H3 and iso-C4H3 can react with acetylene to give phenyl radical with small barriers.
BROADBAND TIME-RESOLVED E{sub p,i}-L{sub iso} CORRELATION IN GAMMA-RAY BURSTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frontera, F.; Guidorzi, C.; Amati, L.
We report the results of a systematic study of the broadband (2-2000 keV) time-resolved prompt emission spectra of a sample of gamma-ray bursts (GRBs) detected with both Wide Field Cameras on board the BeppoSAX satellite and the BATSE experiment on board CGRO. In this first paper, we study the time-resolved dependence of the intrinsic peak energy E{sub p,i} of the E F(E) spectrum on the corresponding isotropic bolometric luminosity L{sub iso}. The E{sub p,i}-L{sub iso} relation or the equivalent relation between E{sub p,i} and the bolometric released energy E{sub iso}, derived using the time-averaged spectra of long GRBs with knownmore » redshift, is well established, but its physical origin is still a subject of discussion. In addition, some authors maintain that these relations are the result of instrumental selection effects. We find that not only a relation between the measured peak energy E{sub p} and the corresponding energy flux, but also a strong E{sub p,i} versus L{sub iso} correlation are found not only within each burst, but also are merging together the time-resolved data points from different GRBs. We do not expect significant instrumental selection effects that can affect the results obtained, apart from the fact that the GRBs in our sample are sufficiently bright to perform a time-resolved spectroscopy and that they have known redshift. If the fundamental physical process that gives rise to the GRB phenomenon does not depend on its brightness, we conclude that the E{sub p,i} versus L{sub iso} correlation found within each GRB is intrinsic to the emission process and that the correlations discovered by Amati et al. and Yonetoku et al. are likely not the result of selection effects. We also discuss the properties of the correlations found.« less
The Quality Movements in Higher Education in the United States.
ERIC Educational Resources Information Center
Miller, Richard I.
1996-01-01
Discussion of various quality control strategies in American higher education looks at and compares Total Quality Management (TQM), outcomes assessment, Deming's 14 points, the Malcolm Baldrige National Quality Award, the ISO 9000 series, restructuring, reengineering, and performance indicators. It is suggested that colleges and universities will…
Options for pricing ancillary services in a deregulated power system
NASA Astrophysics Data System (ADS)
Yamin, Hatim Yahya
2001-07-01
GENCOs in restructured systems are compensated for selling energy in the market. In a restructured market, a mechanism is required to entice participants in the market to provide ancillary services and to ensure adequate compensation that would guarantee its economic viability. The ISO controls the dispatch of generation, manages the reliability of the transmission grid, provides open access to the transmission, buys and provides ancillary services as required, coordinates day-ahead, hour-ahead schedules and performs real time balancing of load and generation, settles real time imbalances and ancillary services sales and purchases. The ISO, also, administers congestion management protocols for the transmission grid. Since the ISO does not own any generating units it must ensure that there is enough reserves for maintaining reliability according to FERC regulations, and sufficient unloaded generating capacity for balancing services in a real-time market. The ISO could meet these requirements by creating a competitive market for ancillary services, which are metered and remain unbundled to provide an accurate compensation for each supplier and cost to each consumer, In this study, we give an overview for restructuring and ancillary services in a restructured power marketplace. Also, we discuss the effect of GENCOs' actions in the competitive energy and ancillary service markets. In addition, we propose an auction market design for hedging ancillary service costs in California market. Furthermore, we show how to include the n-1 and voltage contingencies in security constrained unit commitment. Finally, we present two approaches for GENCOs' unit commitment in a restructured power market; one is based on game theory and the other is based on market price forecasting. In each of the two GENCOs' unit commitment approaches, we discuss the GENCOs' optimal bidding strategies in energy and ancillary service markets to maximize the GENCOs' profit.
Panebianco, Valeria; Sciarra, Alessandro; Osimani, Marcello; Lisi, Danilo; Ciccariello, Mauro; Salciccia, Stefano; Gentile, Vincenzo; Di Silverio, Franco; Passariello, Roberto
2009-01-01
The aim of this study was to assess the capability of a 3D isotropic MRI T2-weighted sequence (3D T2 ISO) in the depiction of changes of neurovascular bundles (NVBs) after bilateral nerve-sparing radical retropubic prostatectomy (RRP). Furthermore, our aim was also to introduce a new MRI classification score of the NVB alteration patterns using the International Index Erectile Function Five-Item (IIEF-5) score as standard of reference. Fifty-three consecutive patients were postoperatively submitted to two MR examinations, including both 2D TSE T2-weighted (2D T2) and 3D T2 ISO sequences. Image findings were scored using a relative five-point classification and correlated with the postoperative IIEF-5 score. Radiologists attributed 13.2% of patients to class 0, 11.3% to class I, 34% to class II, 24.5% to class III, and 16.9% to class IV. With 3D T2 ISO images, the same radiologists determined 43.3% class 0, 32% class I, 11.4% class II, 7.5% class III, and 5.7% class IV. In all cases, the correlation and regression analysis between the 3D T2 ISO and IIEF-5 score resulted in higher coefficients values. The 3D sequence correlated most closely with patients' grading of erectile function.
Exhaust emissions of low level blend alcohol fuels from two-stroke and four-stroke marine engines
NASA Astrophysics Data System (ADS)
Sevik, James M., Jr.
The U.S. Renewable Fuel Standard mandates that by 2022, 36 billion gallons of renewable fuels must be produced on a yearly basis. Ethanol production is capped at 15 billion gallons, meaning 21 billion gallons must come from different alternative fuel sources. A viable alternative to reach the remainder of this mandate is iso-butanol. Unlike ethanol, iso-butanol does not phase separate when mixed with water, meaning it can be transported using traditional pipeline methods. Iso-butanol also has a lower oxygen content by mass, meaning it can displace more petroleum while maintaining the same oxygen concentration in the fuel blend. This research focused on studying the effects of low level alcohol fuels on marine engine emissions to assess the possibility of using iso-butanol as a replacement for ethanol. Three marine engines were used in this study, representing a wide range of what is currently in service in the United States. Two four-stroke engine and one two-stroke engine powered boats were tested in the tributaries of the Chesapeake Bay, near Annapolis, Maryland over the course of two rounds of weeklong testing in May and September. The engines were tested using a standard test cycle and emissions were sampled using constant volume sampling techniques. Specific emissions for two-stroke and four-stroke engines were compared to the baseline indolene tests. Because of the nature of the field testing, limited engine parameters were recorded. Therefore, the engine parameters analyzed aside from emissions were the operating relative air-to-fuel ratio and engine speed. Emissions trends from the baseline test to each alcohol fuel for the four-stroke engines were consistent, when analyzing a single round of testing. The same trends were not consistent when comparing separate rounds because of uncontrolled weather conditions and because the four-stroke engines operate without fuel control feedback during full load conditions. Emissions trends from the baseline test to each alcohol fuel for the two-stroke engine were consistent for all rounds of testing. This is due to the fact the engine operates open-loop, and does not provide fueling compensation when fuel composition changes. Changes in emissions with respect to the baseline for iso-butanol were consistent with changes for ethanol. It was determined iso-butanol would make a viable replacement for ethanol.
Using ISO 25040 standard for evaluating electronic health record systems.
Oliveira, Marília; Novaes, Magdala; Vasconcelos, Alexandre
2013-01-01
Quality of electronic health record systems (EHR-S) is one of the key points in the discussion about the safe use of this kind of system. It stimulates creation of technical standards and certifications in order to establish the minimum requirements expected for these systems. [1] In other side, EHR-S suppliers need to invest in evaluation of their products to provide systems according to these requirements. This work presents a proposal of use ISO 25040 standard, which focuses on the evaluation of software products, for define a model of evaluation of EHR-S in relation to Brazilian Certification for Electronic Health Record Systems - SBIS-CFM Certification. Proposal instantiates the process described in ISO 25040 standard using the set of requirements that is scope of the Brazilian certification. As first results, this research has produced an evaluation model and a scale for classify an EHR-S about its compliance level in relation to certification. This work in progress is part for the acquisition of the degree of master in Computer Science at the Federal University of Pernambuco.
Evaluation of a new filing system's ability to maintain canal morphology.
Thompson, Matthew; Sidow, Stephanie J; Lindsey, Kimberly; Chuang, Augustine; McPherson, James C
2014-06-01
The manufacturer of the Hyflex CM endodontic files claims the files remain centered within the canal, and if unwound during treatment, they will regain their original shape after sterilization. The purpose of this study was to evaluate and compare the canal centering ability of the Hyflex CM and the ProFile ISO filing systems after repeated uses in simulated canals, followed by autoclaving. Sixty acrylic blocks with a canal curvature of 45° were stained with methylene blue, photographed, and divided into 2 groups, H (Hyflex CM) and P (ProFile ISO). The groups were further subdivided into 3 subgroups: H1, H2, H3; P1, P2, P3 (n = 10). Groups H1 and P1 were instrumented to 40 (.04) with the respective file system. Used files were autoclaved for 26 minutes at 126°C. After sterilization, the files were used to instrument groups H2 and P2. The same sterilization and instrumentation procedure was repeated for groups H3 and P3. Post-instrumentation digital images were taken and superimposed over the pre-instrumentation images. Changes in the location of the center of the canal at predetermined reference points were recorded and compared within subgroups and between filing systems. Statistical differences in intergroup and intragroup transportation measures were analyzed by using the Kruskal-Wallis analysis of variance of ranks with the Bonferroni post hoc test. There was a difference between Hyflex CM and ProFile ISO groups, although it was not statistically significant. Intragroup differences for both Hyflex CM and ProFile ISO groups were not significant (P < .05). The Hyflex CM and ProFile ISO files equally maintained the original canal's morphology after 2 sterilization cycles. Published by Elsevier Inc.
Ito, Keisuke; Saito, Akihiro; Fujie, Toshinori; Miyazaki, Hiromi; Kinoshita, Manabu; Saitoh, Daizoh; Ohtsubo, Shinya; Takeoka, Shinji
2016-04-01
Ultra-thin polymer films (nanosheets) fabricated by a layer-by-layer (LbL) method possess unique properties such as high flexibility, adhesive strength, and transparency, and can be peeled off from a substrate and attached to various surfaces via a water-soluble supporting film. Therefore, flexible and transferrable LbL nanosheets are convenient tools as coating materials. Here, we fabricated a novel antimicrobial coating material by embedding silver nanoparticles (AgNPs) in an LbL nanosheet composed of layers of chitosan and sodium alginate (Ag-LbL nanosheet) by means of a photo-reduction method. Optimizing the amount of irradiated energy applied led to robust antimicrobial efficacy against methicillin-resistant Staphylococcus aureus (MRSA), sufficient to meet ISO standards (ISO 22196), while maintaining the flexibility and adhesive potency of the LbL nanosheet. Thus, the Ag-LbL nanosheet is a promising coating material that can provide antimicrobial efficacy to various surfaces. © 2015 Wiley Periodicals, Inc.
Vibration and impulsivity analysis of hand held olive beaters.
Deboli, Roberto; Calvo, Angela; Preti, Christian
2016-07-01
To provide more effective evaluations of hand arm vibration syndromes caused by hand held olive beaters, this study focused on two aspects: the acceleration measured at the tool pole and the analysis of the impulsivity, using the crest factor. The signals were frequency weighted using the weighting curve Wh as described in the ISO 5349-1 standard. The same source signals were also filtered by the Wh-bl filter (ISO/TS 15694), because the weighting filter Wh (unlike the Wh-bl filter) could underestimate the effect of high frequency vibration on vibration-induced finger disorders. Ten (experienced) male operators used three beater models (battery powered) in the real olive harvesting condition. High vibration total values were obtained with values never lower than 20 m(-2). Concerning the crest factor, the values ranged from 5 to more than 22. This work demonstrated that the hand held olive beaters produced high impulsive loads comparable to the industry hand held tools. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Chance-Constrained System of Systems Based Operation of Power Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kargarian, Amin; Fu, Yong; Wu, Hongyu
In this paper, a chance-constrained system of systems (SoS) based decision-making approach is presented for stochastic scheduling of power systems encompassing active distribution grids. Based on the concept of SoS, the independent system operator (ISO) and distribution companies (DISCOs) are modeled as self-governing systems. These systems collaborate with each other to run the entire power system in a secure and economic manner. Each self-governing system accounts for its local reserve requirements and line flow constraints with respect to the uncertainties of load and renewable energy resources. A set of chance constraints are formulated to model the interactions between the ISOmore » and DISCOs. The proposed model is solved by using analytical target cascading (ATC) method, a distributed optimization algorithm in which only a limited amount of information is exchanged between collaborative ISO and DISCOs. In this paper, a 6-bus and a modified IEEE 118-bus power systems are studied to show the effectiveness of the proposed algorithm.« less
Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe
2014-11-01
Polyethylene wear (PE) is known to be a limiting factor in total joint replacements. However, a standardized wear test (e.g. ISO standard) can only replicate the complex in vivo loading condition in a simplified form. In this study, two different parameters were analyzed: (a) Bovine serum, as a substitute for synovial fluid, is typically replaced every 500,000 cycles. However, a continuous regeneration takes place in vivo. How does serum-replacement interval affect the wear rate of total knee replacements? (b) Patients with an artificial joint show reduced gait frequencies compared to standardized testing. What is the influence of a reduced frequency? Three knee wear tests were run: (a) reference test (ISO), (b) testing with a shortened lubricant replacement interval, (c) testing with reduced frequency. The wear behavior was determined based on gravimetric measurements and wear particle analysis. The results showed that the reduced test frequency only had a small effect on wear behavior. Testing with 1 Hz frequency is therefore a valid method for wear testing. However, testing with a shortened replacement interval nearly doubled the wear rate. Wear particle analysis revealed only small differences in wear particle size between the different tests. Wear particles were not linearly released within one replacement interval. The ISO standard should be revised to address the marked effects of lubricant replacement interval on wear rate.
Incident Management Capability Metrics Version 0.1
2007-04-01
guidance for proactively securing and hardening their infrastructure, for example6: • ISO 17799 ( ISO /IEC 17799:2005) [ ISO 2005a] • ISO 27001 ( ISO /IEC... 27001 :2005) [ ISO 2005b] • Control Objectives for Information and related Technology (COBIT) [ITGI 2006...security management systems – Requirements ( ISO /IEC 27001 :2005).http://www.iso.org/ iso /en/CatalogueDetailPage.CatalogueDetail?CSNUMBER=421 03 (2005
Improvement Technology Classification and Composition in Multimodel Environments
2008-03-01
ISO 15504, ISO 12207 , and others COBIT, ITIL, SOX, and...Practice Elements CMMI PAs and PLA ISO 15504 and ISO 12207 COBIT EFQM ISO 9001 Improvement Method Elements Change management techniques: IDEAL and Six...others EFQM and others ISO 9001, ISO 61508, ISO 16949, and others Improvement Method Elements Change management techniques: IDEAL, Six Sigma,
Load application for the contact mechanics analysis and wear prediction of total knee replacement.
Zhang, Jing; Chen, Zhenxian; Wang, Ling; Li, Dichen; Jin, Zhongmin
2017-05-01
Tibiofemoral contact forces in total knee replacement have been measured at the medial and lateral sites respectively using an instrumented prosthesis, and predicted from musculoskeletal multibody dynamics models with a reasonable accuracy. However, it is uncommon that the medial and lateral forces are applied separately to replace a total axial load according to the ISO standard in the majority of current finite element analyses. In this study, we quantified the different effects of applying the medial and lateral loads separately versus the traditional total axial load application on contact mechanics and wear prediction of a patient-specific knee prosthesis. The load application position played an important role under the medial-lateral load application. The loading set which produced the closest load distribution to the multibody dynamics model was used to predict the contact mechanics and wear for the prosthesis and compared with the total axial load application. The medial-lateral load distribution using the present method was found to be closer to the multibody dynamics prediction than the traditional total axial load application, and the maximum contact pressure and contact area were consistent with the corresponding load variation. The predicted total volumetric wear rate and area were similar between the two load applications. However, the split of the predicted wear volumes on the medial and the lateral sides was different. The lateral volumetric wear rate was 31.46% smaller than the medial from the traditional load application prediction, while from the medial-lateral load application, the lateral side was only 11.8% smaller than the medial. The medial-lateral load application could provide a new and more accurate method of load application for patient-specific preclinical contact mechanics and wear prediction of knee implants.
Changing Regulations of COD Pollution Load of Weihe River Watershed above TongGuan Section, China
NASA Astrophysics Data System (ADS)
Zhu, Lei; Liu, WanQing
2018-02-01
TongGuan Section of Weihe River Watershed is a provincial section between Shaanxi Province and Henan Province, China. Weihe River Watershed above TongGuan Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a method—characteristic section load (CSLD) method is suggested and point and non-point source pollution loads of Weihe River Watershed above TongGuan Section are calculated in the rainy, normal and dry season in 2013. The results show that the monthly point source pollution loads of Weihe River Watershed above TongGuan Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above TongGuan Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the rainy, wet and normal period in turn.
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2017-12-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. Weihe River Watershed above Huaxian Section is taken as the research objective in this paper and COD is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load(CSLD) method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly and the non-point source pollution load proportions of total pollution load of COD decrease in the normal, rainy and wet period in turn.
Calculating NH3-N pollution load of wei river watershed above Huaxian section using CSLD method
NASA Astrophysics Data System (ADS)
Zhu, Lei; Song, JinXi; Liu, WanQing
2018-02-01
Huaxian Section is the last hydrological and water quality monitoring section of Weihe River Watershed. So it is taken as the research objective in this paper and NH3-N is chosen as the water quality parameter. According to the discharge characteristics of point source pollutions and non-point source pollutions, a new method to estimate pollution loads—characteristic section load (CSLD)method is suggested and point source pollution and non-point source pollution loads of Weihe River Watershed above Huaxian Section are calculated in the rainy, normal and dry season in the year 2007. The results show that the monthly point source pollution loads of Weihe River Watershed above Huaxian Section discharge stably and the monthly non-point source pollution loads of Weihe River Watershed above Huaxian Section change greatly. The non-point source pollution load proportions of total pollution load of NH3-N decrease in the normal, rainy and wet period in turn.
Amoush, Ahmad; Wilkinson, Douglas A.
2015-01-01
This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantage 125I seeds. In addition, the dosimetry parameters Λ, gL(r), and F(r,θ) were calculated for the IsoAid Advantage model IAI‐125 125I seed and benchmarked against published data. Bebig Plaque Simulator (PS) v5.74 was used to calculate the central axis dose based on the AAPM Updated Task Group 43 (TG‐43U1) dose formalism. The calculated central axis dose from MC and PS was then compared. When the MC dosimetry parameters for the IsoAid Advantage 125I seed were compared with the consensus values, Λ agreed with the consensus value to within 2.3%. However, much larger differences were found between MC calculated gL(r) and F(r,θ) and the consensus values. The differences between MC‐calculated dosimetry parameters are much smaller when compared with recently published data. The differences between the calculated central axis absolute dose from MC and PS ranged from 5% to 10% for distances between 1 and 12 mm from the outer scleral surface. When the dosimetry parameters for the 125I seed from this study were used in PS, the calculated absolute central axis dose differences were reduced by 2.3% from depths of 4 to 12 mm from the outer scleral surface. We conclude that PS adequately models the central dose profile of this plaque using its defaults for the IsoAid model IAI‐125 at distances of 1 to 7 mm from the outer scleral surface. However, improved dose accuracy can be obtained by using updated dosimetry parameters for the IsoAid model IAI‐125 125I seed. PACS number: 87.55.K‐ PMID:26699577
Tong, Yanhong; McCarthy, Kaitlin; Kong, Huimin; Lemieux, Bertrand
2012-11-01
We have developed a rapid and simple molecular test, the IsoGlow HSV Typing assay, for the detection and typing of herpes simplex virus (type 1 and 2) from genital or oral lesions. Clinical samples suspended in viral transport mediums are simply diluted and then added to a helicase-dependent amplification master mix. The amplification and detection were performed on a portable fluorescence detector called the FireFly instrument. Detection of amplification products is based on end-point analysis using cycling probe technology. An internal control nucleic acid was included in the amplification master mix to monitor the presence of amplification inhibitors in the samples. Because the device has only two fluorescence detection channels, two strategies were developed and compared to detect the internal control template: internal control detected by melting curve analysis using a dual-labeled probe, versus internal control detection using end-point fluorescence release by a CPT probe at a lower temperature. Both have a total turnaround time of about 1 hour. Clinical performance relative to herpes viral culture was evaluated using 176 clinical specimens. Both formats of the IsoGlow HSV typing assay had sensitivities comparable to that of the Food and Drug Administration-cleared IsoAmp HSV (BioHelix Corp., Beverly MA) test and specificity for the two types of HSV comparable to that of ELVIS HSV (Diagnostic Hybrids, Athens, OH). Copyright © 2012 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Tomsick, T A; Foster, L D; Liebeskind, D S; Hill, M D; Carrozella, J; Goyal, M; von Kummer, R; Demchuk, A M; Dzialowski, I; Puetz, V; Jovin, T; Morales, H; Palesch, Y Y; Broderick, J; Khatri, P; Yeatts, S D
2015-11-01
Intracarotid arterial infusion of nonionic, low-osmolal iohexol contrast medium has been associated with increased intracranial hemorrhage in a rat middle cerebral artery occlusion model compared with saline infusion. Iso-osmolal iodixanol (290 mOsm/kg H2O) infusion demonstrated smaller infarcts and less intracranial hemorrhage compared with low-osmolal iopamidol and saline. No studies comparing iodinated radiographic contrast media in human stroke have been performed, to our knowledge. We hypothesized that low-osmolal contrast media may be associated with worse outcomes compared with iodixanol in the Interventional Management of Stroke III Trial (IMS III). We reviewed prospective iodinated radiographic contrast media data for 133 M1 occlusions treated with endovascular therapy. We compared 5 prespecified efficacy and safety end points (mRS 0-2 outcome, modified TICI 2b-3 reperfusion, asymptomatic and symptomatic intracranial hemorrhage, and mortality) between those receiving iodixanol (n = 31) or low-osmolal contrast media (n = 102). Variables imbalanced between iodinated radiographic contrast media types or associated with outcome were considered potential covariates for the adjusted models. In addition to the iodinated radiographic contrast media type, final covariates were those selected by using the stepwise method in a logistic regression model. Adjusted relative risks were then estimated by using a log-link regression model. Of baseline or endovascular therapy variables potentially linked to outcome, prior antiplatelet agent use was more common and microcatheter iodinated radiographic contrast media injections were fewer with iodixanol. Relative risk point estimates are in favor of iodixanol for the 5 prespecified end points with M1 occlusion. The percentage of risk differences are numerically greater for microcatheter injections with iodixanol. While data favoring the use of iso-osmolal iodixanol for reperfusion of M1 occlusion following IV rtPA are inconclusive, potential pathophysiologic mechanisms suggesting clinical benefit warrant further investigation. © 2015 by American Journal of Neuroradiology.
A Structured Approach for Reviewing Architecture Documentation
2009-12-01
as those found in ISO 12207 [ ISO /IEC 12207 :2008] (for software engineering), ISO 15288 [ ISO /IEC 15288:2008] (for systems engineering), the Rational...Open Distributed Processing - Reference Model: Foundations ( ISO /IEC 10746-2). 1996. [ ISO /IEC 12207 :2008] International Organization for...Standardization & International Electrotechnical Commission. Sys- tems and software engineering – Software life cycle processes ( ISO /IEC 12207 ). 2008. [ ISO
Analysis of lubricating oils in shear friction tests using infrared thermography
NASA Astrophysics Data System (ADS)
Da Silva, José Jorge; Maribondo, Juscelino de Farias
2018-03-01
The aim of this work is to analyze the ability of Thermography to monitor the behavior of SAE 20 W50 API SJ and ISO VG 10 lubricating oils from the thermal point of view until the moment of the lubricant film rupture, characterized by the sudden increase in friction, noise, vibration and Temperature in a shear friction test. The methodology used is based on the analysis of thermograms that indicate temperature profiles during the friction tests and at the moment of mechanical failure, comparing these results with those obtained by a thermocouple. The specimens, consisting of SAE 1045 steel cylindrical pins, are rubbed against a wear ring consisting of a weld-locked bearing under the condition of a boundary lubrication regime. Tests were performed by increasing load conditions up to 180 N at 10, 15 and 20 Hz rotations (600, 900 and 1200 rpm). The results show the qualitative and quantitative capacity of the Thermography in the detection of scuffing considering the emissivity of the lubricating oil film equal to 0,82. It is concluded that the Thermography can be used for the detection of the breaking of the lubricating film in pin-on-ring friction tests.
RES-loaded pegylated CS NPs: for efficient ocular delivery.
Pandian, Saravanakumar; Jeevanesan, Vinoth; Ponnusamy, Chandrasekar; Natesan, Subramanian
2017-02-01
The objective of this study is to develop resveratrol (RES) loaded polyethylene glycols (PEGs) modified chitosan (CS) nanoparticles (NPs) by ionic gelation method for the treatment of glaucoma. While increasing the concentration of PEG, the particle size and polydispersity index of the formulations increased. Entrapment efficiency and RES loading (RL) of NPs decreased while increasing PEG concentration. The in vitro release of NPs showed an initial burst release of RES (45%) followed by controlled release. Osmolality of formulations revealed that the prepared NPs were iso-osmolar with the tear. Ocular tolerance of the NPs was evaluated using hen's egg test on the chorioallantoic membrane and it showed that the NPs were non-irritant. RES-loaded PEG-modified CS NPs shows an improved corneal permeation compared with RES dispersion. Fluorescein isothiocyanate loaded CS NPs accumulated on the surface of the cornea but the PEG-modified CS NPs crossed the cornea and reached retinal choroid. RES-loaded PEG-modified CS NPs reduced the intra-ocular pressure (IOP) by 4.3 ± 0.5 mmHg up to 8 h in normotensive rabbits. These results indicate that the developed NPs have efficient delivery of RES to the ocular tissues and reduce the IOP for the treatment of glaucoma.
Big Geo Data Services: From More Bytes to More Barrels
NASA Astrophysics Data System (ADS)
Misev, Dimitar; Baumann, Peter
2016-04-01
The data deluge is affecting the oil and gas industry just as much as many other industries. However, aside from the sheer volume there is the challenge of data variety, such as regular and irregular grids, multi-dimensional space/time grids, point clouds, and TINs and other meshes. A uniform conceptualization for modelling and serving them could save substantial effort, such as the proverbial "department of reformatting". The notion of a coverage actually can accomplish this. Its abstract model in ISO 19123 together with the concrete, interoperable OGC Coverage Implementation Schema (CIS), which is currently under adoption as ISO 19123-2, provieds a common platform for representing any n-D grid type, point clouds, and general meshes. This is paired by the OGC Web Coverage Service (WCS) together with its datacube analytics language, the OGC Web Coverage Processing Service (WCPS). The OGC WCS Core Reference Implementation, rasdaman, relies on Array Database technology, i.e. a NewSQL/NoSQL approach. It supports the grid part of coverages, with installations of 100+ TB known and single queries parallelized across 1,000+ cloud nodes. Recent research attempts to address the point cloud and mesh part through a unified query model. The Holy Grail envisioned is that these approaches can be merged into a single service interface at some time. We present both grid amd point cloud / mesh approaches and discuss status, implementation, standardization, and research perspectives, including a live demo.
Nonlinear effects of stretch on the flame front propagation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halter, F.; Tahtouh, T.; Mounaim-Rousselle, C.
2010-10-15
In all experimental configurations, the flames are affected by stretch (curvature and/or strain rate). To obtain the unstretched flame speed, independent of the experimental configuration, the measured flame speed needs to be corrected. Usually, a linear relationship linking the flame speed to stretch is used. However, this linear relation is the result of several assumptions, which may be incorrected. The present study aims at evaluating the error in the laminar burning speed evaluation induced by using the traditional linear methodology. Experiments were performed in a closed vessel at atmospheric pressure for two different mixtures: methane/air and iso-octane/air. The initial temperaturesmore » were respectively 300 K and 400 K for methane and iso-octane. Both methodologies (linear and nonlinear) are applied and results in terms of laminar speed and burned gas Markstein length are compared. Methane and iso-octane were chosen because they present opposite evolutions in their Markstein length when the equivalence ratio is increased. The error induced by the linear methodology is evaluated, taking the nonlinear methodology as the reference. It is observed that the use of the linear methodology starts to induce substantial errors after an equivalence ratio of 1.1 for methane/air mixtures and before an equivalence ratio of 1 for iso-octane/air mixtures. One solution to increase the accuracy of the linear methodology for these critical cases consists in reducing the number of points used in the linear methodology by increasing the initial flame radius used. (author)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skippon, S.M.; Tagaki, Y.
1996-09-01
The evaporation of fuel droplets is an important factor in determining the quality of mixture preparation in lean-burn engines, particularly when using open-valve injection timing, which results in large in-cylinder droplet populations. Interferometric Laser Imaging for Droplet Sizing (ILIDS) has been used to measure the in-cylinder droplet size distribution and fuel volume in the droplet phase as a function of crank angle for a typical full boiling range gasoline and three single component fuels with different boiling points: iso-pentane, iso-octane, and xylene, representing the volatilities of the light end, mid-range and heavy ends of a typical gasoline. The measurements weremore » made under firing conditions, with both open and closed valve injection timing, and at two different coolant temperatures, representing simulated cold start and fully warmed up conditions. A specially built single cylinder research engine was used, equipped with a transparent sapphire cylinder to provide all-round sidewall optical access to the cylinder interior. The engine had a four-valve leanburn head, swirl control valve and air-assisted injector. The experimental arrangements for ILIDS in a firing engine, and the optical access engine itself, are discussed in detail. The results showed significant differences in the rates of evaporation of the three fuel components: iso-pentane evaporated fully very early in the induction stroke, iso-octane droplets persisted longer, and xylene droplets persisted to the end of the compression stroke.« less
CMMI (Trademark) for Development, Version 1.2
2006-08-01
IEC TR 12207 Information Technology—Software Life Cycle Processes, 1995. http://www.jtc1-sc7.org. ISO 1998 International Organization for...We also consult other standards as needed, including the following: • ISO 9000 [ ISO 1987] • ISO /IEC 12207 [ ISO 1995] • ISO /IEC 15504 [ ISO 2006... ISO /IEC) body of standards. CMMs focus on improving processes in an organization. They contain the essential elements of effective processes for one
CrossTalk: The Journal of Defense Software Engineering. Volume 21, Number 12
2008-12-01
that provide recognized certifications, and examples of how these standards relate. The first qual- ification ( ISO 27000 ) should be strongly considered...Several ISO 20000 requirements relate to ISO 27000 and ISO 9001. As a result, achieving ISO 20000 cer- tification helps an organization to also...achieve ISO 9001 and ISO 27000 certifica- tion. ISO 20000 certification can also help organizations with CMMI® appraisals. Table 1 also shows some of the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banik, Nilanjan; Tan, Jonathan C.; Monaco, Pierluigi
We calculate the cosmic distributions in space and time of the formation sites of the first, "Pop III.1" stars, exploring a model in which these are the progenitors of all supermassive black holes (SMBHs). Pop III.1 stars are defined to form from primordial composition gas in dark matter minihalos withmore » $$\\sim10^6\\:M_\\odot$$ that are isolated from neighboring astrophysical sources by a given isolation distance, $$d_{\\rm{iso}}$$. We assume Pop III.1 sources are seeds of SMBHs, based on protostellar support by dark matter annihilation heating that allows them to accrete a large fraction of their minihalo gas, i.e., $$\\sim 10^5\\:M_\\odot$$. Exploring $$d_{\\rm{iso}}$$ from 10--$$100\\:\\rm{kpc}$$ (proper distances), we predict the redshift evolution of Pop III.1 source and SMBH remnant number densities. The local, $z=0$ density of SMBHs constrains $$d_{\\rm{iso}}\\lesssim 100\\:\\rm{kpc}$$ (i.e., $$3\\:\\rm{Mpc}$$ comoving distance at $$z\\simeq30$$). In our simulated ($$\\sim60\\:\\rm{Mpc}$$)$^3$ comoving volume, Pop III.1 stars start forming just after $z=40$. Their formation is largely complete by $$z\\simeq25$$ to 20 for $$d_{\\rm{iso}}=100$$ to $$50\\:\\rm{kpc}$$. We follow source evolution to $z=10$, by which point most SMBHs reside in halos with $$\\gtrsim10^8\\:M_\\odot$$. Over this period, there is relatively limited merging of SMBHs for these values of $$d_{\\rm{iso}}$$. We also predict SMBH clustering properties at $z=10$$: feedback suppression of neighboring sources leads to relatively flat angular correlation functions. Finally, we consider a simple "Str\\"omgren" model for $$d_{\\rm iso}$, based on ionizing feedback from zero age main sequence supermassive Pop III.1 stars that may be the direct progenitors of SMBHs in this scenario. Such models naturally produce feedback effects on scales of $$\\sim100\\:$$kpc and thus self-consistently generate a SMBH number density similar to the observed value.« less
Al-Rasheed, Nawal M; Al-Rasheed, Nouf M; Bassiouni, Yieldez A; Hasan, Iman H; Al-Amin, Maha A; Al-Ajmi, Hanaa N; Mohamad, Raeesa A
2015-06-01
A growing body of evidence suggests that immune activation and inflammatory mediators may play a key role in the development and progression of left ventricle (LV) hypertrophy. The present study was designed to test the hypothesis that the cardioprotective effect of cholecalciferol (Vit-D3) is mediated via the regulation of messenger RNA (mRNA) expression of pro-inflammatory cytokines. Rats were randomly divided into four groups: control group received normal saline (0.9 % NaCl) i.p. for 14 days; Vit-D3 group received Vit-D3 at a dose of 12 μg/kg/day by gavage for 14 days; ISO group received saline for 7 days, and at day 7, ISO (5 mg/kg/day) was injected i.p. for 7 consecutive days to induce cardiac hypertrophy; and Vit-D3 + ISO group was treated with Vit-D3 for 14 days, and at day 7, ISO was administered for 7 consecutive days. Heart/body weight ratio, troponin-T, creatine kinase-MB, and tumor necrosis factor-α (TNF-α) levels of LV tissue were estimated. Levels of mRNA expression of NF-кB (NF-кB)/p65 and inhibitory kappa B (IкB)-α were determined by real-time PCR. Vit-D3 administration before and during induction of cardiac hypertrophy significantly reduced (P < 0.001) cardiac biomarkers. The histopathological examination further confirmed these results. In addition, Vit-D3 significantly decreased (P < 0.001) NF-кB-p65 mRNA expression and increased (P < 0.01) IкB-α mRNA expression in LV tissues compared to ISO group. Based on these findings, it was concluded that the administration of cholecalciferol markedly attenuated the development of ISO-induced cardiac hypertrophy likely through downregulation of TNF-α /NF-кb/p65 signaling pathways. However, it should be pointed out that other signaling pathways may contribute to the cardioprotective effect of Vit-D3 which requires further investigation.
Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.
Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar
2012-01-01
Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.
Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients
Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar
2012-01-01
Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310
Enhancing Technology Education Students' Understanding of ISO 9000.
ERIC Educational Resources Information Center
Harding, Kerry A.; Tesolowski, Dennis G.; Simmons, J. Bryan
2000-01-01
Defines ISO 9000, the quality control standard of the International Organization for Standardization (ISO), and looks at the benefits of ISO certification. Looks at the four levels of ISO 9000 and discusses the construction of training courses to prepare ISO documentation. (JOW)
Miyoshi, Toru; Nakamura, Kazufumi; Miura, Daiji; Yoshida, Masashi; Saito, Yukihiro; Akagi, Satoshi; Ohno, Yuko; Kondo, Megumi; Ito, Hiroshi
2018-05-02
Recent clinical studies have shown that treatment with LCZ696, a complex containing the angiotensin receptor blocker valsartan and neprilysin inhibitor sacubitril, improves the prognosis of heart failure patients with a reduced ejection fraction. This study evaluated whether LCZ696 affects left ventricular hypertrophy, fibrosis, and hemodynamics in isoproterenol (ISO)-treated rats compared with valsartan alone. Male Wistar rats received subcutaneous saline (n = 10), subcutaneous ISO (2.4 mg/kg/day; n = 10), subcutaneous ISO + oral LCZ696 (60 mg/kg/day; n = 20) (ISO-LCZ), or subcutaneous ISO + oral valsartan (30 mg/kg/day; n = 20) (ISO-VAL) for 7 days. LCZ696 and valsartan did not significantly reduce the increased heart weight/body weight ratio in rats treated with ISO. Echocardiography showed that the deceleration time shortened by ISO was restored by LCZ696 but not valsartan alone (p = 0.01 vs. the ISO group). Histological analysis showed that cardiac interstitial fibrosis increased by ISO was decreased significantly by LCZ696 but not valsartan alone (control: 0.10 ± 0.14%; ISO: 0.41 ± 0.32%; ISO-LCZ: 0.19 ± 0.23% [p < 0.01 vs. the ISO group]; ISO-VAL: 0.34 ± 0.23% [p = 0.34 vs. the ISO group]). Quantitative PCR showed that mRNA expression of Tgfb1, Col1a1, Ccl2, and Anp increased by ISO was significantly attenuated by LCZ696 but not valsartan alone (p < 0.05 vs. the ISO group). LCZ696 improves cardiac fibrosis, but not hypertrophy, caused by continuous exposure to ISO in rats.
Piacentino, Valentino; Dipla, Konstantina; Gaughan, John P; Houser, Steven R
2000-01-01
Direct voltage-gated (voltage-dependent Ca2+ release, VDCR) and Ca2+ influx-gated (Ca2+-induced Ca2+ release, CICR) sarcoplasmic reticulum (SR) Ca2+ release were studied in feline ventricular myocytes. The voltage-contraction relationship predicted by the VDCR hypothesis is sigmoidal with large contractions at potentials near the Ca2+ equilibrium potential (ECa). The relationship predicted by the CICR hypothesis is bell-shaped with no contraction at ECa. The voltage dependence of contraction was measured in ventricular myocytes at physiological temperature (37 °C), resting membrane potential and physiological [K+]. Experiments were performed with cyclic adenosine 3′,5′-monophosphate (cAMP) in the pipette or in the presence of the β-adrenergic agonist isoproterenol (isoprenaline; ISO). The voltage-contraction relationship was bell-shaped in Na+-free solutions (to eliminate the Na+ current and Na+-Ca2+ exchange, NCX) but the relationship was broader than the L-type Ca2+ current (ICa,L)-voltage relationship. Contractions induced with voltage steps from normal resting potentials to -40 mV are thought to represent VDCR rather than CICR. We found that cAMP and ISO shifted the voltage dependence of ICa,L activation to more negative potentials so that ICa,L was always present with steps to -40 mV. ICa,L at -40 mV inactivated when the holding potential was decreased (V½ =−57·8 ± 0·49 mV). ISO increased inward current, SR Ca2+ load and contraction in physiological [Na+] and a broad bell-shaped voltage-contraction relationship was observed. Inhibition of reverse-mode NCX, decreasing ICa,L and decreasing SR Ca2+ loading all decreased contractions at strongly positive potentials near ECa. The voltage-contraction relationship in 200 μM cadmium (Cd2+) was bell-shaped, supporting a role of ICa,L rather than VDCR. All results could be accounted for by the CICR hypothesis, and many results exclude the VDCR hypothesis. PMID:10718736
NASA Astrophysics Data System (ADS)
Zhang, Li
With the deregulation of the electric power market in New England, an independent system operator (ISO) has been separated from the New England Power Pool (NEPOOL). The ISO provides a regional spot market, with bids on various electricity-related products and services submitted by utilities and independent power producers. A utility can bid on the spot market and buy or sell electricity via bilateral transactions. Good estimation of market clearing prices (MCP) will help utilities and independent power producers determine bidding and transaction strategies with low risks, and this is crucial for utilities to compete in the deregulated environment. MCP prediction, however, is difficult since bidding strategies used by participants are complicated and MCP is a non-stationary process. The main objective of this research is to provide efficient short-term load and MCP forecasting and corresponding confidence interval estimation methodologies. In this research, the complexity of load and MCP with other factors is investigated, and neural networks are used to model the complex relationship between input and output. With improved learning algorithm and on-line update features for load forecasting, a neural network based load forecaster was developed, and has been in daily industry use since summer 1998 with good performance. MCP is volatile because of the complexity of market behaviors. In practice, neural network based MCP predictors usually have a cascaded structure, as several key input factors need to be estimated first. In this research, the uncertainties involved in a cascaded neural network structure for MCP prediction are analyzed, and prediction distribution under the Bayesian framework is developed. A fast algorithm to evaluate the confidence intervals by using the memoryless Quasi-Newton method is also developed. The traditional back-propagation algorithm for neural network learning needs to be improved since MCP is a non-stationary process. The extended Kalman filter (EKF) can be used as an integrated adaptive learning and confidence interval estimation algorithm for neural networks, with fast convergence and small confidence intervals. However, EKF learning is computationally expensive because it involves high dimensional matrix manipulations. A modified U-D factorization within the decoupled EKF (DEKF-UD) framework is developed in this research. The computational efficiency and numerical stability are significantly improved.
Stamer, J.K.; Cherry, R.N.; Faye, R.E.; Kleckner, R.L.
1978-01-01
On an average annual basis and during the storm period of March 12-15, 1976, nonpoint-source loads for most constituents were larger than point-source loads at the Whitesburg station, located on the Chattahoochee River about 40 miles downstream from Atlanta, GA. Most of the nonpoint-source constituent loads in the Atlanta to Whitesburg reach were from urban areas. Average annual point-source discharges accounted for about 50 percent of the dissolved nitrogen, total nitrogen, and total phosphorus loads and about 70 percent of the dissolved phosphorus loads at Whitesburg. During a low-flow period, June 1-2, 1977, five municipal point-sources contributed 63 percent of the ultimate biochemical oxygen demand, and 97 percent of the ammonium nitrogen loads at the Franklin station, at the upstream end of West Point Lake. Dissolved-oxygen concentrations of 4.1 to 5.0 milligrams per liter occurred in a 22-mile reach of the river downstream from Atlanta due about equally to nitrogenous and carbonaceous oxygen demands. The heat load from two thermoelectric powerplants caused a decrease in dissolved-oxygen concentration of about 0.2 milligrams per liter. Phytoplankton concentrations in West Point Lake, about 70 miles downstream from Atlanta, could exceed three million cells per millimeter during extended low-flow periods in the summer with present point-source phosphorus loads. (Woodard-USGS)
Precise determination of time to reach viral load set point after acute HIV-1 infection.
Huang, Xiaojie; Chen, Hui; Li, Wei; Li, Haiying; Jin, Xia; Perelson, Alan S; Fox, Zoe; Zhang, Tong; Xu, Xiaoning; Wu, Hao
2012-12-01
The HIV viral load set point has long been used as a prognostic marker of disease progression and more recently as an end-point parameter in HIV vaccine clinical trials. The definition of set point, however, is variable. Moreover, the earliest time at which the set point is reached after the onset of infection has never been clearly defined. In this study, we obtained sequential plasma viral load data from 60 acutely HIV-infected Chinese patients among a cohort of men who have sex with men, mathematically determined viral load set point levels, and estimated time to attain set point after infection. We also compared the results derived from our models and that obtained from an empirical method. With novel uncomplicated mathematic model, we discovered that set points may vary from 21 to 119 days dependent on the patients' initial viral load trajectory. The viral load set points were 4.28 ± 0.86 and 4.25 ± 0.87 log10 copies per milliliter (P = 0.08), respectively, as determined by our model and an empirical method, suggesting an excellent agreement between the old and new methods. We provide a novel method to estimate viral load set point at the very early stage of HIV infection. Application of this model can accurately and reliably determine the set point, thus providing a new tool for physicians to better monitor early intervention strategies in acutely infected patients and scientists to rationally design preventative vaccine studies.
Analyzing Cases of Resilience Success and Failure - A Research Study
2012-12-01
controls [NIST 2012, NIST 2008] ISO 27002 and ISO 27004 Guidelines for initiating, implementing, maintaining, and improving information security...Commission ( ISO /IEC). Information technology—Security techniques—Code of practice for information security management ( ISO /IEC 27002 :2005). ISO /IEC, 2005...security management system and controls or groups of controls [ ISO /IEC 2005, ISO /IEC 2009] CIS Security Metrics Outcome and practice metrics measuring
Coalition Network Defence Common Operational Picture
2010-11-01
27000 .org/ iso -27005.htm [26] ISO 8601:2004, Data elements and interchange formats - Information interchange - Representation of dates and times, http://ww.iso.org, http://en.wikipedia.org/wiki/ISO_8601 ...Regular_expression [25] ISO /IEC 27005:2008, Information technology -- Security techniques -- Information security risk management, http://ww.iso.org,; http://www
Review of the National Information Assurance Partnership (NIAP)
2006-01-01
accreditation is to ensure that laboratories meet the re- quirements of ISO / IEC 17025 :2005, General Requirement for the Competence of Cali- bration and...isoguide2. [ISO1999] ISO / IEC 17025 , General Requirements for the Competence of Testing and Calibration Laboratories, 1999, http://www.iso.ch/ iso ...Protection Profiles and Secu- rity Targets, 2003. [ISO2005] ISO / IEC 17025 , General Requirements for the Competence of Testing and Calibration Laboratories
Robertazzi, Thomas G.; Skiena, Steven; Wang, Kai
2017-08-08
Provided are an apparatus and method for load-balancing of a three-phase electric power distribution system having a multi-phase feeder, including obtaining topology information of the feeder identifying supply points for customer loads and feeder sections between the supply points, obtaining customer information that includes peak customer load at each of the points between each of the feeder sections, performing a phase balancing analysis, and recommending phase assignment at the customer load supply points.
Gijzen, Karlijn; Moolenaar, David L J; Weusten, Jos J A M; Pluim, Hendrik J; Demir, Ayse Y
2012-11-01
Implementation of tight glycemic control (TGC) and avoidance of hypoglycemia in intensive care unit (ICU) patients require frequent analysis of blood glucose. This can be achieved by accurate point-of-care (POC) hospital-use glucose meters. In this study one home-use and four different hospital-use POC glucose meters were evaluated in critically ill ICU patients. All patients (n = 80) requiring TGC were included in this study. For each patient three to six glucose measurements (n = 390) were performed. Blood glucose was determined by four hospital-use POC glucose meters, Roche Accu-Check Inform II System, HemoCue Glu201DM, Nova StatStrip, Abbott Precision Xceed Pro, and one home-use POC glucose meter, Menarini GlucoCard Memory PC. The criteria described in ISO 15197, Dutch TNO quality guideline and in NACB/ADA-2011 were applied in the comparisons. According to the ISO 15197, the percentages of the measured values that fulfilled the criterion were 99.5% by Roche, 95.1% by HemoCue, 91.0% by Nova, 96.6% by Abbott, and 63.3% by Menarini. According to the TNO quality guideline these percentages were 96.1% , 91.0% , 81.8% , 94.2% , and 47.7% , respectively. Application of the NACB/ADA guideline resulted in percentages of 95.6%, 89.2%, 77.9%, 93.4%, and 45.4%, respectively. When ISO 15197 was applied, Roche, HemoCue and Abbott fulfilled the criterion in this patient population, whereas Nova and Menarini did not. However, when TNO quality guideline and NACB/ADA 2011 guideline were applied only Roche fulfilled the criteria.
ISO Technical Specification for the Ionosphere -IRI Recent Activities
NASA Astrophysics Data System (ADS)
Bilitza, Dieter; Reinisch, Bodo; Tamara, Gulyaeva
ISO Technical Specification TS 16457 recommends the International Reference Ionosphere (IRI) for the specification of ionospheric densities and temperatures. We review the latest develop-ments towards improving the IRI model and the newest version of the model IRI-2010. IRI-2010 includes several important improvements and additions. This presentation introduces these changes and discusses their benefits. The changes affect primarily the density profiles in the bottomside ionosphere and the density and height of the F2 peak, the point of highest density in the ionosphere. An important new addition to the model is the inclusion of auroral boundaries and their movement with magnetic activity. We will also discuss the status of other ongoing IRI activities and some of the recent applications of the IRI model. The homepage for the IRI project is at http://IRI.gsfc.nasa.gov/.
Seismic Hazard Assessment of Tehran Based on Arias Intensity
NASA Astrophysics Data System (ADS)
Amiri, G. Ghodrati; Mahmoodi, H.; Amrei, S. A. Razavian
2008-07-01
In this paper probabilistic seismic hazard assessment of Tehran for Arias intensity parameter is done. Tehran is capital and most populated city of Iran. From economical, political and social points of view, Tehran is the most significant city of Iran. Since in the previous centuries, catastrophic earthquakes have occurred in Tehran and its vicinity, probabilistic seismic hazard assessment of this city for Arias intensity parameter is useful. Iso-intensity contour lines maps of Tehran on the basis of different attenuation relationships for different earthquake periods are plotted. Maps of iso-intensity points in the Tehran region are presented using proportional attenuation relationships for rock and soil beds for 2 hazard levels of 10% and 2% in 50 years. Seismicity parameters on the basis of historical and instrumental earthquakes for a time period that initiate from 4th century BC and ends in the present time are calculated using Tow methods. For calculation of seismicity parameters, the earthquake catalogue with a radius of 200 km around Tehran has been used. SEISRISKIII Software has been employed. Effects of different parameters such as seismicity parameters, length of fault rupture relationships and attenuation relationships are considered using Logic Tree.
Seismic Hazard Assessment of Tehran Based on Arias Intensity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amiri, G. Ghodrati; Mahmoodi, H.; Amrei, S. A. Razavian
2008-07-08
In this paper probabilistic seismic hazard assessment of Tehran for Arias intensity parameter is done. Tehran is capital and most populated city of Iran. From economical, political and social points of view, Tehran is the most significant city of Iran. Since in the previous centuries, catastrophic earthquakes have occurred in Tehran and its vicinity, probabilistic seismic hazard assessment of this city for Arias intensity parameter is useful. Iso-intensity contour lines maps of Tehran on the basis of different attenuation relationships for different earthquake periods are plotted. Maps of iso-intensity points in the Tehran region are presented using proportional attenuation relationshipsmore » for rock and soil beds for 2 hazard levels of 10% and 2% in 50 years. Seismicity parameters on the basis of historical and instrumental earthquakes for a time period that initiate from 4th century BC and ends in the present time are calculated using Tow methods. For calculation of seismicity parameters, the earthquake catalogue with a radius of 200 km around Tehran has been used. SEISRISKIII Software has been employed. Effects of different parameters such as seismicity parameters, length of fault rupture relationships and attenuation relationships are considered using Logic Tree.« less
Darwish, Hany W; Bakheit, Ahmed H; Naguib, Ibrahim A
2016-01-01
This paper presents novel methods for spectrophotometric determination of ascorbic acid (AA) in presence of rutin (RU) (coformulated drug) in their combined pharmaceutical formulation. The seven methods are ratio difference (RD), isoabsorptive_RD (Iso_RD), amplitude summation (A_Sum), isoabsorptive point, first derivative of the ratio spectra ((1)DD), mean centering (MCN), and ratio subtraction (RS). On the other hand, RU was determined directly by measuring the absorbance at 358 nm in addition to the two novel Iso_RD and A_Sum methods. The work introduced in this paper aims to compare these different methods, showing the advantages for each and making a comparison of analysis results. The calibration curve is linear over the concentration range of 4-50 μg/mL for AA and RU. The results show the high performance of proposed methods for the analysis of the binary mixture. The optimum assay conditions were established and the proposed methods were successfully applied for the assay of the two drugs in laboratory prepared mixtures and combined pharmaceutical tablets with excellent recoveries. No interference was observed from common pharmaceutical additives.
Darwish, Hany W.; Bakheit, Ahmed H.; Naguib, Ibrahim A.
2016-01-01
This paper presents novel methods for spectrophotometric determination of ascorbic acid (AA) in presence of rutin (RU) (coformulated drug) in their combined pharmaceutical formulation. The seven methods are ratio difference (RD), isoabsorptive_RD (Iso_RD), amplitude summation (A_Sum), isoabsorptive point, first derivative of the ratio spectra (1DD), mean centering (MCN), and ratio subtraction (RS). On the other hand, RU was determined directly by measuring the absorbance at 358 nm in addition to the two novel Iso_RD and A_Sum methods. The work introduced in this paper aims to compare these different methods, showing the advantages for each and making a comparison of analysis results. The calibration curve is linear over the concentration range of 4–50 μg/mL for AA and RU. The results show the high performance of proposed methods for the analysis of the binary mixture. The optimum assay conditions were established and the proposed methods were successfully applied for the assay of the two drugs in laboratory prepared mixtures and combined pharmaceutical tablets with excellent recoveries. No interference was observed from common pharmaceutical additives. PMID:26885440
Development of STEP-NC Adaptor for Advanced Web Manufacturing System
NASA Astrophysics Data System (ADS)
Ajay Konapala, Mr.; Koona, Ramji, Dr.
2017-08-01
Information systems play a key role in the modern era of Information Technology. Rapid developments in IT & global competition calls for many changes in basic CAD/CAM/CAPP/CNC manufacturing chain of operations. ‘STEP-NC’ an enhancement to STEP for operating CNC machines, creating new opportunities for collaborative, concurrent, adaptive works across the manufacturing chain of operations. Schemas and data models defined by ISO14649 in liaison with ISO10303 standards made STEP-NC file rich with feature based, rather than mere point to point information of G/M Code format. But one needs to have a suitable information system to understand and modify these files. Various STEP-NC information systems are reviewed to understand the suitability of STEP-NC for web manufacturing. Present work also deals with the development of an adaptor which imports STEP-NC file, organizes its information, allowing modifications to entity values and finally generates a new STEP-NC file to export. The system is designed and developed to work on web to avail additional benefits through the web and also to be part of a proposed ‘Web based STEP-NC manufacturing platform’ which is under development and explained as future scope.
Experimental compliance calibration of the compact fracture toughness specimen
NASA Technical Reports Server (NTRS)
Fisher, D. M.; Buzzard, R. J.
1980-01-01
Compliances and stress intensity coefficients were determined over crack length to width ratios from 0.1 to 0.8. Displacements were measured at the load points, load line, and crack mouth. Special fixturing was devised to permit accurate measurement of load point displacement. The results are in agreement with the currently used results of boundary collocation analyses. The errors which occur in stress intensity coefficients or specimen energy input determinations made from load line displacement measurements rather than from load point measurements are emphasized.
El Agaty, Sahar M
2018-03-08
To assess the effect of vitamin D 2 and to elucidate the underlying mechanisms on acute myocardial injury induced by isoproterenol (ISO) in diabetic rats. Rats were divided into control rats, diabetic rats (DM), diabetic rats received ISO (DM-ISO), and diabetic rats pretreated with vitamin D 2 and received ISO (DM-D 2 -ISO). Vitamin D 2 pretreatment significantly decreased fasting glucose and myocardial malondialdehyde, associated with increased insulin, myocardial glutathione and superoxide dismutase in DM-D 2 -ISO versus DM-ISO. The serum triglycerides, total cholesterol, and LDL were significantly decreased, along with increased HDL and adiponectin. Poly-ADP ribose polymerase, cyclooxygenase-2, tumour necrosis factor alpha, interleukin-6, caspase-3, BAX, and p53 were significantly downregulated in myocardium of DM-D 2 -ISO versus DM-ISO. Histological studies showed diminished inflammatory cells infiltration in myocardium of DM-D 2 -ISO versus DM-ISO. Vitamin D 2 ameliorates hyperglycaemia, dyslipidaemia, redox imbalance, inflammatory and apoptotic processes, protecting the myocardium of diabetic rats against acute myocardial infarction.
Synthesis and Biological Activity of 2',3'-iso-Aryl-abscisic Acid Analogs.
Wan, Chuan; Wang, Mingan; Yang, Dongyan; Han, Xiaoqiang; Che, Chuanliang; Ding, Shanshan; Xiao, Yumei; Qin, Zhaohai
2017-12-15
2',3'- iso -Benzoabscisic acid ( iso -PhABA), an excellent selective abscisic acid (ABA) analog, was developed in our previous work. In order to find its more structure-activity information, some structural modifications were completed in this paper, including the substitution of phenyl ring and replacing the ring with heterocycles. Thus, 16 novel analogs of iso -PhABA were synthesized and screened with three bioassays, Arabidopsis and lettuce seed germination and rice seedling elongation. Some of them, i.e., 2',3'- iso -pyridoabscisic acid ( iso -PyABA) and 2',3'- iso -franoabscisic acid ( iso -FrABA), displayed good bioactivities that closed to iso -PhABA and natural (+)-ABA. Some others, for instance, substituted- iso -PhABA, exhibited certain selectivity to different physiological process when compared to iso -PhABA or (+)-ABA. These analogs not only provided new candidates of ABA-like synthetic plant growth regulators (PGRs) for practical application, but also new potential selective agonist/antagonist for probing the specific function of ABA receptors.
SU-F-J-37: Commissioning a Six Degree of Freedom Couch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, D; Lam, K; Bredfeldt, J
2016-06-15
Purpose: The proper operation of a six degree of freedom couch (6DOFC) to position a patient for treatment requires that a number systems on the treatment unit work together correctly. Commissioning a 6DOFC requires not only the commissioning of each separate system but also commissioning the interactions between the systems. Methods: To commission a 6DOFC, we tested the resolvers that readout the linear and angular positions; the orthogonality of the axes of the laser positioning system, the imaging system, the gantry and the couch as well as their relationship to each other. An automated Winston-Lutz test was used verify themore » coincidence of the origins of the laser system, imaging system and treatment unit. The IsoCal phantom was used to verify the consistency of axes orientations between systems. The operation of the couch and imaging system was verified under simulated load conditions and an end to end test was performed to verify correct operation of the system. Results: The tests on the couch resolvers, orthogonality and coincidence of the axes of each system were successfully completed and showed excellent agreement. The automated Winston-Lutz test showed that the maximum displacement of the center of the radiation field with respect to the isocenter was <0.6 mm (radius) at isocenter. The analysis of the IsoCal phantom showed that the maximum variation of the radiation field with respect to known locations in the phantom was ∼0.9 mm for all the BBs in the phantom. Load tests showed maximum errors of 1 mm. Conclusion: We tested all system associated with the 6DOFC and found the uncertainty due to imaging was <.9mm and the uncertainty due to loading ∼1 mm, resulting in a total error of ∼1.4 mm.« less
Launching the chaotic realm of iso-fractals: A short remark
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Schmidt, Nathan; Katebi, Reza; Corda, Christian
In this brief note, we introduce the new, emerging sub-discipline of iso-fractals by highlighting and discussing the preliminary results of recent works. First, we note the abundance of fractal, chaotic, non-linear, and self-similar structures in nature while emphasizing the importance of studying such systems because fractal geometry is the language of chaos. Second, we outline the iso-fractal generalization of the Mandelbrot set to exemplify the newly generated Mandelbrot iso-sets. Third, we present the cutting-edge notion of dynamic iso-spaces and explain how a mathematical space can be iso-topically lifted with iso-unit functions that (continuously or discretely) change; in the discrete casemore » examples, we mention that iteratively generated sequences like Fibonacci’s numbers and (the complex moduli of) Mandelbrot’s numbers can supply a deterministic chain of iso-units to construct an ordered series of (magnified and/or de-magnified) iso-spaces that are locally iso-morphic. Fourth, we consider the initiation of iso-fractals with Inopin’s holographic ring (IHR) topology and fractional statistics for 2D and 3D iso-spaces. In total, the reviewed iso-fractal results are a significant improvement over traditional fractals because the application of Santilli’s iso-mathematics arms us an extra degree of freedom for attacking problems in chaos. Finally, we conclude by proposing some questions and ideas for future research work.« less
Arvanitoyannis, Ioannis S; Varzakas, Theodoros H
2008-05-01
The Failure Mode and Effect Analysis (FMEA) model was applied for risk assessment of salmon manufacturing. A tentative approach of FMEA application to the salmon industry was attempted in conjunction with ISO 22000. Preliminary Hazard Analysis was used to analyze and predict the occurring failure modes in a food chain system (salmon processing plant), based on the functions, characteristics, and/or interactions of the ingredients or the processes, upon which the system depends. Critical Control points were identified and implemented in the cause and effect diagram (also known as Ishikawa, tree diagram and fishbone diagram). In this work, a comparison of ISO 22000 analysis with HACCP is carried out over salmon processing and packaging. However, the main emphasis was put on the quantification of risk assessment by determining the RPN per identified processing hazard. Fish receiving, casing/marking, blood removal, evisceration, filet-making cooling/freezing, and distribution were the processes identified as the ones with the highest RPN (252, 240, 210, 210, 210, 210, 200 respectively) and corrective actions were undertaken. After the application of corrective actions, a second calculation of RPN values was carried out resulting in substantially lower values (below the upper acceptable limit of 130). It is noteworthy that the application of Ishikawa (Cause and Effect or Tree diagram) led to converging results thus corroborating the validity of conclusions derived from risk assessment and FMEA. Therefore, the incorporation of FMEA analysis within the ISO 22000 system of a salmon processing industry is anticipated to prove advantageous to industrialists, state food inspectors, and consumers.
Arvanitoyannis, Ioannis S; Varzakas, Theodoros H
2009-08-01
Failure Mode and Effect Analysis (FMEA) has been applied for the risk assessment of snails manufacturing. A tentative approach of FMEA application to the snails industry was attempted in conjunction with ISO 22000. Preliminary Hazard Analysis was used to analyze and predict the occurring failure modes in a food chain system (snails processing plant), based on the functions, characteristics, and/or interactions of the ingredients or the processes, upon which the system depends. Critical Control points have been identified and implemented in the cause and effect diagram (also known as Ishikawa, tree diagram, and fishbone diagram). In this work a comparison of ISO22000 analysis with HACCP is carried out over snails processing and packaging. However, the main emphasis was put on the quantification of risk assessment by determining the RPN per identified processing hazard. Sterilization of tins, bioaccumulation of heavy metals, packaging of shells and poisonous mushrooms, were the processes identified as the ones with the highest RPN (280, 240, 147, 144, respectively) and corrective actions were undertaken. Following the application of corrective actions, a second calculation of RPN values was carried out leading to considerably lower values (below the upper acceptable limit of 130). It is noteworthy that the application of Ishikawa (Cause and Effect or Tree diagram) led to converging results thus corroborating the validity of conclusions derived from risk assessment and FMEA. Therefore, the incorporation of FMEA analysis within the ISO22000 system of a snails processing industry is considered imperative.
Dorjgochoo, Tsogzolmaa; Gao, Yu-Tang; Chow, Wong-Ho; Shu, Xiao-ou; Yang, Gong; Cai, Qiuyin; Rothman, Nathaniel; Cai, Hui; Li, Honglan; Deng, Xinqing; Franke, Adrian; Roberts, L Jackson; Milne, Ginger; Zheng, Wei; Dai, Qi
2012-01-01
Background: There is limited literature on the contributors to isoprostane metabolite 2,3-dinor-5,6-dihydro-15-F2t-isoprostane (15-F2t-IsoP-M) compared with F2-isoprostanes (F2-IsoPs) as an oxidative stress biomarker. Objective: The objective of this study was to investigate whether plasma concentrations of antioxidants, urinary excretion rates of polyphenols, and antioxidants in food and dietary supplements are attributable to both urinary F2-IsoP and 15-F2t-IsoP-M concentrations. Design: Dietary intake information and blood and urine samples were obtained from 845 healthy middle-aged and elderly female participants of the Shanghai Women's Health Study. Urinary isoprostanes (F2-IsoPs and 15-F2t-IsoP-M) were measured and adjusted for creatinine concentrations. Results: Urinary 15-F2t-IsoP-M and F2-IsoP concentrations were lower in subjects who used a multivitamin. Lower F2-IsoP concentrations were observed in ginseng users, whereas lower concentrations of 15-F2t-IsoP-M were shown in subjects who used a vitamin E supplement. Plasma concentrations of several antioxidants (ie, β-carotenes, both trans and cis β-carotenes, lycopene other than trans, 5-cis and 7-cis isomers, cis anhydrolutein, and cis β-cryptoxanthin) were inversely associated with 15-F2t-IsoP-M but not with F2-IsoPs, whereas β-, γ-, and δ-tocopherols were positively associated with 15-F2t-IsoP-M but not with F2-IsoPs. Urinary polyphenol quercetin was positively associated with both F2-IsoPs and 15-F2t-IsoP-M. Conclusion: The results suggest that the F2-IsoP major metabolite 15-F2t-IsoP-M may be a more sensitive marker of endogenous oxidative stress status than are F2-IsoPs in the assessment of effects of antioxidants on age-related diseases. PMID:22760572
Wise, Daniel R.; Rinella, Frank A.; Rinella, Joseph F.; Fuhrer, Greg J.; Embrey, Sandra S.; Clark, Gregory M.; Schwarz, Gregory E.; Sobieszczyk, Steven
2007-01-01
This study focused on three areas that might be of interest to water-quality managers in the Pacific Northwest: (1) annual loads of total nitrogen (TN), total phosphorus (TP) and suspended sediment (SS) transported through the Columbia River and Puget Sound Basins, (2) annual yields of TN, TP, and SS relative to differences in landscape and climatic conditions between subbasin catchments (drainage basins), and (3) trends in TN, TP, and SS concentrations and loads in comparison to changes in landscape and climatic conditions in the catchments. During water year 2000, an average streamflow year in the Pacific Northwest, the Columbia River discharged about 570,000 pounds per day of TN, about 55,000 pounds per day of TP, and about 14,000 tons per day of SS to the Pacific Ocean. The Snake, Yakima, Deschutes, and Willamette Rivers contributed most of the load discharged to the Columbia River. Point-source nutrient loads to the catchments (almost exclusively from municipal wastewater treatment plants) generally were a small percentage of the total in-stream nutrient loads; however, in some reaches of the Spokane, Boise, Walla Walla, and Willamette River Basins, point sources were responsible for much of the annual in-stream nutrient load. Point-source nutrient loads generally were a small percentage of the total catchment nutrient loads compared to nonpoint sources, except for a few catchments where point-source loads comprised as much as 30 percent of the TN load and as much as 80 percent of the TP load. The annual TN and TP loads from point sources discharging directly to the Puget Sound were about equal to the annual loads from eight major tributaries. Yields of TN, TP, and SS generally were greater in catchments west of the Cascade Range. A multiple linear regression analysis showed that TN yields were significantly (p < 0.05) and positively related to precipitation, atmospheric nitrogen load, fertilizer and manure load, and point-source load, and were negatively related to average slope. TP yields were significantly related positively to precipitation, and point-source load and SS yields were significantly related positively to precipitation. Forty-eight percent of the available monitoring sites for TN had significant trends in concentration (2 increasing, 19 decreasing), 32 percent of the available sites for TP had significant trends in concentration (7 increasing, 9 decreasing), and 40 percent of the available sites for SS had significant trends in concentration (4 increasing, 15 decreasing). The trends in load followed a similar pattern, but with fewer sites showing significant trends. The results from this study indicate that inputs from nonpoint sources of nutrients probably have decreased over time in many of the catchments. Despite the generally small contribution of point-source nutrient loads, they still may have been partially responsible for the significant decreasing trends for nutrients at sites where the total point-source nutrient loads to the catchments equaled a substantial proportion of the in-stream load.
Protective and therapeutic effects of dexpanthenol on isoproterenol-induced cardiac damage in rats.
Kalkan, Ferhat; Parlakpinar, Hakan; Disli, Olcay M; Tanriverdi, Lokman H; Ozhan, Onural; Polat, Alaaddin; Cetin, Aslı; Vardi, Nigar; Otlu, Yılmaz O; Acet, Ahmet
2018-05-18
The purpose of the study was to explore the protective and therapeutic effects of dexpanthenol (DEX) on isoproterenol (ISO)-induced cardiac damage. Forty rats were distributed into four groups: group I (Control); group II (ISO); ISO (150 mg/kg/day) was given to rats once a day for 2 consecutive days with an interval of 24 h; group III (DEX+ISO): DEX (250 mg/kg) was applied 30 min before the first ISO administration and continued in the next two days after second ISO administration; group IV (ISO+DEX): After the ISO treatment at 1st and 2nd days, DEX was given at 3rd and 4th days. Rats were monitored for mean arterial blood pressure (BP), heart rate, oxygen saturation (%SO 2 ), and electrocardiography (ECG). Heart tissue levels of malondialdehyde (MDA), superoxide dismutase (SOD), catalase (CAT), glutathione peroxidase (GPX), reduced glutathione (GSH), total oxidant status (TOS); total antioxidant capacity (TAC), oxidative stress index (OSI), and caspase-3 were determined. BP and SO 2 values indicated a significant decrease in the ISO group. Also, T wave negativity was observed in 6 of 10 rats, SOD, CAT, and GPX levels were significantly lower in ISO group than control group. ISO administration increased TOS and OSI levels, whereas DEX treatment significantly reduced these parameters. Also, ISO-induced morphological alterations such as disorganization of cardiomyocytes, loss of myofibrils and cytoplasmic vacuolization whereas these histological damages were significantly decreased in ISO+DEX and DEX+ISO groups when compared to the ISO group. This study implies the cardioprotective effects of DEX on ISO-induced cardiotoxicity. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magnucka-Blandzi, Ewa
The study is devoted to stability of simply supported beam under axial compression. The beam is subjected to an axial load located at any point along the axis of the beam. The buckling problem has been desribed and solved mathematically. Critical loads have been calculated. In the particular case, the Euler’s buckling load is obtained. Explicit solutions are given. The values of critical loads are collected in tables and shown in figure. The relation between the point of the load application and the critical load is presented.
Naval Open Architecture Contract Guidebook for Program Managers
2010-06-30
a whole, transform inputs into outputs. [IEEE/EIA Std. 12207 /1997] “APP233/ ISO 10303” – APP233 an “Application Protocol” for Systems Engineering...Language Metadata Interchange (XMI) and AP233/ ISO 10303). The contractor shall identify the proposed standards and formats to be used. The contractor...ANSI ISO /IEC 9075-1, ISO /IEC 9075-2, ISO /IEC 9075-3, ISO /IEC 9075-4, ISO /IEC 9075-5) 2. HTML for presentation layer (e.g., XML 1.0
2010-06-01
7 Table 2. ISO 14001 versus ISO 50001 (From: Integrated Renewable Energy , 2010...the ISO is expected to release ISO 50001 , Management System for Energy (MSE) at the end of 2010 (Pinero, 2009, pp. 18–22). Standard 50001 is based...35 Table 2. ISO 14001 versus ISO 50001 (From: Integrated Renewable Energy , 2010) 36 ISO 50001 will focus a company’s attention on
Farinango, Charic D; Benavides, Juan S; Cerón, Jesús D; López, Diego M; Álvarez, Rosa E
2018-01-01
Previous studies have demonstrated the effectiveness of information and communication technologies to support healthy lifestyle interventions. In particular, personal health record systems (PHR-Ss) empower self-care, essential to support lifestyle changes. Approaches such as the user-centered design (UCD), which is already a standard within the software industry (ISO 9241-210:2010), provide specifications and guidelines to guarantee user acceptance and quality of eHealth systems. However, no single PHR-S for metabolic syndrome (MS) developed following the recommendations of the ISO 9241-210:2010 specification has been found in the literature. The aim of this study was to describe the development of a PHR-S for the management of MS according to the principles and recommendations of the ISO 9241-210 standard. The proposed PHR-S was developed using a formal software development process which, in addition to the traditional activities of any software process, included the principles and recommendations of the ISO 9241-210 standard. To gather user information, a survey sample of 1,187 individuals, eight interviews, and a focus group with seven people were performed. Throughout five iterations, three prototypes were built. Potential users of each system evaluated each prototype. The quality attributes of efficiency, effectiveness, and user satisfaction were assessed using metrics defined in the ISO/IEC 25022 standard. The following results were obtained: 1) a technology profile from 1,187 individuals at risk for MS from the city of Popayan, Colombia, identifying that 75.2% of the people use the Internet and 51% had a smartphone; 2) a PHR-S to manage MS developed (the PHR-S has the following five main functionalities: record the five MS risk factors, share these measures with health care professionals, and three educational modules on nutrition, stress management, and a physical activity); and 3) usability tests on each prototype obtaining the following results: 100% effectiveness, 100% efficiency, and 84.2 points in the system usability scale. The software development methodology used was based on the ISO 9241-210 standard, which allowed the development team to maintain a focus on user's needs and requirements throughout the project, which resulted in an increased satisfaction and acceptance of the system. Additionally, the establishment of a multidisciplinary team allowed the application of considerations not only from the disciplines of software engineering and health sciences but also from other disciplines such as graphical design and media communication. Finally, usability testing allowed the observation of flaws in the designs, which helped to improve the solution.
Yock, Adam D; Pawlicki, Todd; Kim, Gwe-Ya
2016-07-01
In surface image guided radiosurgery, action limits are created to determine at what point intrafractional motion exhibited by the patient is large enough to warrant intervention. Action limit values remain constant across patients despite the fact that patient motion affects the target coverage of brain metastases differently depending on the planning technique and other treatment plan-specific factors. The purpose of this work was twofold. The first purpose was to characterize the sensitivity of single-met per iso and multimet per iso treatment plans to uncorrected patient motion. The second purpose was to describe a method to prospectively determine treatment plan-specific action limits considering this sensitivity. In their surface image guided radiosurgery technique, patient positioning is achieved with a thermoplastic mask that does not cover the patient's face. The patient's exposed face is imaged by a stereoscopic photogrammetry system. It is then compared to a reference surface and monitored throughout treatment. Seventy-two brain metastases (representing 29 patients) were used for this study. Twenty-five mets were treated individually ("single-met per iso plans"), and 47 were treated in a plan simultaneously with at least one other met ("multimet per iso plans"). For each met, the proportion of the gross tumor volume that remained within the 100% prescription isodose line was estimated under the influence of combinations of translations and rotations (0.0-3.0 mm and 0.0°-3.0°, respectively). The target volume and the prescription dose-volume were considered concentric spheres that each encompassed a volume determined from the treatment plan. Plan-specific contour plots and DVHs were created to illustrate the sensitivity of a specific lesion to uncorrected patient motion. Both single-met per iso and multimet per iso plans exhibited compromised target coverage under translations and rotations, though multimet per iso plans were considerably more sensitive to these transformations (2.3% and 39.8%, respectively). Plan-specific contour plots and DVHs were used to illustrate how size, distance from isocenter, and planning technique affect a particular met's sensitivity to motion. Stereotactic radiosurgery treatment plans that treat multiple brain metastases using a common isocenter are particularly susceptible to compromised target coverage as a result of uncorrected patient motion. The use of such a planning technique along with other treatment plan-specific factors should influence patient motion management. A graphical representation of the effect of translations and rotations on any particular plan can be generated to inform clinicians of the appropriate action limit when monitoring intrafractional motion.
Promoting Strong ISO 50001 Outcomes with Supportive National Infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKane, Aimee, T.; Siciliano, Graziella; de los Reyes, Pamela
The ISO 50001 standard is a key mechanism for reducing greenhouse gas emissions and improving energy efficiency globally. An increasing number of companies are seeking certification, creating the need for personnel that are competent to conduct ISO 50001 certification audits. The growth of ISO 50001 is expected to accelerate as more companies integrate ISO 50001 into their corporate sustainability strategies and supplier requirements. Robust implementation of ISO 50001 represents an important tool for countries with climate change mitigation goals. Because of its dual focus on continual improvement of an organization’s energy management system (EnMS) and its energy performance improvement, ISOmore » 50001 requires skills of both implementers and certification auditors that are not well-supported by current credentials and training. This paper describes an effort to address skill gaps of certification auditors, a critical factor to ensure that ISO 50001 implementations are robust and result in continued energy performance improvement. A collaboration of governments through the Energy Management Working Group (EMWG), formerly under Global Superior Energy Performance (GSEP), has formed to build workforce capacity for ISO 50001 certification audits. The EMWG is leading the development of an internationally-relevant certification scheme for ISO 50001 Lead Auditor that meets requirements for ISO/IEC 17024 accreditation and ISO 50003 for defining ISO 50001 Lead Auditor competency. Wider availability of competent ISO 50001 Lead Auditors will ultimately increase the impact and market value of ISO 50001 certification and improve consistency of ISO 50001 certification outcomes by establishing a standardized and high level of knowledge and skills globally.« less
Axial calibration methods of piezoelectric load sharing dynamometer
NASA Astrophysics Data System (ADS)
Zhang, Jun; Chang, Qingbing; Ren, Zongjin; Shao, Jun; Wang, Xinlei; Tian, Yu
2018-06-01
The relationship between input and output of load sharing dynamometer is seriously non-linear in different loading points of a plane, so it's significant for accutately measuring force to precisely calibrate the non-linear relationship. In this paper, firstly, based on piezoelectric load sharing dynamometer, calibration experiments of different loading points are performed in a plane. And then load sharing testing system is respectively calibrated based on BP algorithm and ELM (Extreme Learning Machine) algorithm. Finally, the results show that the calibration result of ELM is better than BP for calibrating the non-linear relationship between input and output of loading sharing dynamometer in the different loading points of a plane, which verifies that ELM algorithm is feasible in solving force non-linear measurement problem.
NASA Astrophysics Data System (ADS)
Codina, R.; Ambrosini, D.
2018-03-01
For the last few decades, the effects of blast loading on structures have been studied by many researchers around the world. Explosions can be caused by events such as industrial accidents, military conflicts or terrorist attacks. Urban centers have been prone to various threats including car bombs, suicide attacks, and improvised explosive devices. Partially vented constructions subjected to external blast loading represent an important topic in protective engineering. The assessment of blast survivability inside structures and the development of design provisions with respect to internal elements require the study of the propagation and leakage of blast waves inside buildings. In this paper, full-scale tests are performed to study the effects of the leakage of blast waves inside a partially vented room that is subjected to different external blast loadings. The results obtained may be useful for proving the validity of different methods of calculation, both empirical and numerical. Moreover, the experimental results are compared with those computed using the empirical curves of the US Defense report/manual UFC 3-340. Finally, results of the dynamic response of the front masonry wall are presented in terms of accelerations and an iso-damage diagram.
Effect of cements on fracture resistance of monolithic zirconia crowns
Nakamura, Keisuke; Mouhat, Mathieu; Nergård, John Magnus; Lægreid, Solveig Jenssen; Kanno, Taro; Milleding, Percy; Örtengren, Ulf
2016-01-01
Abstract Objectives The present study investigated the effect of cements on fracture resistance of monolithic zirconia crowns in relation to their compressive strength. Materials and methods Four different cements were tested: zinc phosphate cement (ZPC), glass-ionomer cement (GIC), self-adhesive resin-based cement (SRC) and resin-based cement (RC). RC was used in both dual cure mode (RC-D) and chemical cure mode (RC-C). First, the compressive strength of each cement was tested according to a standard (ISO 9917-1:2004). Second, load-to-failure test was performed to analyze the crown fracture resistance. CAD/CAM-produced monolithic zirconia crowns with a minimal thickness of 0.5 mm were prepared and cemented to dies with each cement. The crown–die samples were loaded until fracture. Results The compressive strength of SRC, RC-D and RC-C was significantly higher than those of ZPC and GIC (p < 0.05). However, there was no significant difference in the fracture load of the crown between the groups. Conclusion The values achieved in the load-to-failure test suggest that monolithic zirconia crowns with a minimal thickness of 0.5 mm may have good resistance against fracture regardless of types of cements. PMID:27335900
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milatovic, Dejan, E-mail: dejan.milatovic@vanderbilt.edu; Gupta, Ramesh C.; Yu, Yingchun
Exposure to excessive manganese (Mn) levels leads to neurotoxicity, referred to as manganism, which resembles Parkinson's disease (PD). Manganism is caused by neuronal injury in both cortical and subcortical regions, particularly in the basal ganglia. The basis for the selective neurotoxicity of Mn is not yet fully understood. However, several studies suggest that oxidative damage and inflammatory processes play prominent roles in the degeneration of dopamine-containing neurons. In the present study, we assessed the effects of Mn on reactive oxygen species (ROS) formation, changes in high-energy phosphates and associated neuronal dysfunctions both in vitro and in vivo. Results from ourmore » in vitro study showed a significant (p < 0.01) increase in biomarkers of oxidative damage, F{sub 2}-isoprostanes (F{sub 2}-IsoPs), as well as the depletion of ATP in primary rat cortical neurons following exposure to Mn (500 {mu}M) for 2 h. These effects were protected when neurons were pretreated for 30 min with 100 of an antioxidant, the hydrophilic vitamin E analog, trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), or an anti-inflammatory agent, indomethacin. Results from our in vivo study confirmed a significant increase in F{sub 2}-IsoPs levels in conjunction with the progressive spine degeneration and dendritic damage of the striatal medium spiny neurons (MSNs) of mice exposed to Mn (100 mg/kg, s.c.) 24 h. Additionally, pretreatment with vitamin E (100 mg/kg, i.p.) or ibuprofen (140 {mu}g/ml in the drinking water for two weeks) attenuated the Mn-induced increase in cerebral F{sub 2}-IsoPs? and protected the MSNs from dendritic atrophy and dendritic spine loss. Our findings suggest that the mediation of oxidative stress/mitochondrial dysfunction and the control of alterations in biomarkers of oxidative injury, neuroinflammation and synaptodendritic degeneration may provide an effective, multi-pronged therapeutic strategy for protecting dysfunctional dopaminergic transmission and slowing of the progression of Mn-induced neurodegenerative processes. -- Research highlights: Black-Right-Pointing-Pointer Mn exposure leads to neurotoxicity in vitro and in vivo. Black-Right-Pointing-Pointer Antioxidants and anti-inflammatory agents attenuate Mn-induced oxidative injury. Black-Right-Pointing-Pointer These agents also protect the striatal neurons from dendritic atrophy and spine loss. Black-Right-Pointing-Pointer These prophylactic strategies may be effective against Mn neurotoxicity.« less
Carnevale, Roberto; Iuliano, Luigi; Nocella, Cristina; Bartimoccia, Simona; Trapè, Stefano; Russo, Roberta; Gentile, Maria Cristina; Cangemi, Roberto; Loffredo, Lorenzo; Pignatelli, Pasquale; Violi, Francesco
2013-06-14
Urinary 8-iso-PGF2α, a marker of oxidative stress, is influenced by the activation of NOX2. It is unclear if platelets 8-iso-PGF2α contribute to urinary 8-iso-PGF2α. In a cross-sectional study, platelet, urinary, and serum 8-iso-PGF2α were determined in subjects with downregulation (X-linked chronic granulomatous disease [X-CGD], n=25) and upregulation (type II diabetic patients [T2D], n=121) of NOX2 and 153 controls matched for sex and age. In diabetic patients (n=18), the above variables were repeated before and after 7 days treatment with 100 mg/day aspirin or 100 mg/day aspirin plus 40 mg/day atorvastatin. In vitro study was performed to see the contribution of blood cells to serum 8-iso-PGF2α. Compared with controls, X-CGD patients had lower platelet, serum, and urinary 8-iso-PGF2α values; conversely, diabetic patients had higher values of 8-iso-PGF2α compared with controls. Urinary 8-iso-PGF2α significantly correlated with both platelet and serum 8-iso-PGF2α in the 2 cohorts. A parallel increase of platelet, serum, and urinary 8-iso-PGF2α by aspirin and a parallel decrease by aspirin plus atorvastatin were detected in the interventional study. In vitro study demonstrated that platelets contribute to 37% of serum 8-iso-PGF2α and that only 13% of it is of extravascular origin. The study suggests that NOX2 contributes to the formation of 8-iso-PGF2α in both platelets and urine. The direct correlation between platelet and urinary 8-iso-PGF2α suggests that, at least partly, urinary 8-iso-PGF2α reflects platelet 8-iso-PGF2α production. Analysis of serum 8-iso-PGF2α may represent a novel tool to investigate the production of 8-iso-PGF2α by blood cells including platelets. URL: ClinicalTrials.gov. Unique Identifier: NCT01250340.
High speed cinematography of the initial break-point of latex condoms during the air burst test.
Stube, R; Voeller, B; Davidhazy, A
1990-06-01
High speed cinematography of latex condoms inflated to burst under standard (ISO) conditions reveals that rupture of the condom typically is initiated at a small focal point on the shank of the condom and then rapidly propagates throughout the condom's surface, often ending with partial or full severance of the condom at its point of attachment to the air burst instrument. This sequence of events is the reverse of that sometimes hypothesized to occur, where initiation of burst was considered to begin at the attachment point and to constitute a testing method artifact. This hypothesis of breakage at the attachment point, if true, would diminish the value of the air burst test as a standard for assessing manufacturing quality control as well as for condom strength measurements and comparisons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.
2010-09-01
The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and windmore » forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.« less
Neonatal isoflavone exposure interferes with the reproductive system of female Wistar rats.
Müller, Dennis R; Soukup, Sebastian T; Kurrat, Anne; Liu, Xin; Schmicke, Marion; Xie, Ming-Yong; Kulling, Sabine E; Diel, Patrick
2016-11-16
There is increasing concern about possible adverse effects of soy based infant formulas (SBIF) due to their high amount of isoflavones (ISO). The aim of the present study was to investigate effects of neonatal exposure to ISO on reproductive system of female Wistar rats. Animals were exposed to an ISO depleted diet or a diet enriched with an ISO extract (IRD; 508mg ISO/kg) during embryogenesis and adolescence. Pups of each group were fed daily by pipette with ISO-suspension (ISO+; 32mg ISO/kg bw) or placebo from postnatal day (PND) 1 until PND23 resulting in plasma concentrations similar to levels reported in infants fed SBIF. The visceral fat mass was reduced by long-term IRD. Vaginal epithelial height was increased at PND23 and vaginal opening was precocious in ISO+ groups. Later in life, more often irregular estrus cycles were observed in rats of ISO+ groups. In addition, FSH levels and uterine epithelial heights were increased at PND80 in ISO+ groups. In summary, the results indicate that neonatal ISO intake, resulting in plasma concentrations achievable through SBIF, has an estrogenic effect on prepubertal rats and influences female reproductive tract later in life. Copyright © 2016. Published by Elsevier Ireland Ltd.
Engineering of CRISPR/Cas9‐mediated potyvirus resistance in transgene‐free Arabidopsis plants
Pyott, Douglas E.; Sheehan, Emma
2016-01-01
Summary Members of the eukaryotic translation initiation factor (eIF) gene family, including eIF4E and its paralogue eIF(iso)4E, have previously been identified as recessive resistance alleles against various potyviruses in a range of different hosts. However, the identification and introgression of these alleles into important crop species is often limited. In this study, we utilise CRISPR/Cas9 technology to introduce sequence‐specific deleterious point mutations at the eIF(iso)4E locus in Arabidopsis thaliana to successfully engineer complete resistance to Turnip mosaic virus (TuMV), a major pathogen in field‐grown vegetable crops. By segregating the induced mutation from the CRISPR/Cas9 transgene, we outline a framework for the production of heritable, homozygous mutations in the transgene‐free T2 generation in self‐pollinating species. Analysis of dry weights and flowering times for four independent T3 lines revealed no differences from wild‐type plants under standard growth conditions, suggesting that homozygous mutations in eIF(iso)4E do not affect plant vigour. Thus, the established CRISPR/Cas9 technology provides a new approach for the generation of Potyvirus resistance alleles in important crops without the use of persistent transgenes. PMID:27103354
Optical Fourier filtering for whole lens assessment of progressive power lenses.
Spiers, T; Hull, C C
2000-07-01
Four binary filter designs for use in an optical Fourier filtering set-up were evaluated when taking quantitative measurements and when qualitatively mapping the power variation of progressive power lenses (PPLs). The binary filters tested were concentric ring, linear grating, grid and "chevron" designs. The chevron filter was considered best for quantitative measurements since it permitted a vernier acuity task to be used for measuring the fringe spacing, significantly reducing errors, and it also gave information on the polarity of the lens power. The linear grating filter was considered best for qualitatively evaluating the power variation. Optical Fourier filtering and a Nidek automatic focimeter were then used to measure the powers in the distance and near portions of five PPLs of differing design. Mean measurement error was 0.04 D with a maximum value of 0.13 D. Good qualitative agreement was found between the iso-cylinder plots provided by the manufacturer and the Fourier filter fringe patterns for the PPLs indicating that optical Fourier filtering provides the ability to map the power distribution across the entire lens aperture without the need for multiple point measurements. Arguments are presented that demonstrate that it should be possible to derive both iso-sphere and iso-cylinder plots from the binary filter patterns.
Paepoemsin, T; Reichart, P A; Chaijareenont, P; Strietzel, F P; Khongkhunthian, P
2016-01-01
The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer's recommended torque. Ten specimens in each group underwent cyclic loading (1×106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, P<.05). After cyclic loading, removal torque in all groups decreased significantly (P<.05). Group C revealed significantly less removal torque than groups A and B (P<.005). Tensile force in all groups significantly increased after cyclic loading (P<.05), group A had significantly less tensile force than groups B and C (P<.005). Removal torque reduced significantly after cyclic loading. Before cyclic loading, tapered screws maintained more preload than did flat head screws. After cyclic loading, tapered and flat head screws maintained even amounts of preload. The tensile force that dislodged abutment from implant fixture increased immensely after cyclic loading.
PAEPOEMSIN, T.; REICHART, P. A.; CHAIJAREENONT, P.; STRIETZEL, F. P.; KHONGKHUNTHIAN, P.
2016-01-01
SUMMARY Purpose The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. Methods The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index. All screws were tightened with manufacturer’s recommended torque. Ten specimens in each group underwent cyclic loading (1×106 cycles, 10 Hz, and 250 N). Then, all specimens were un-tightened, measured for the removal torque, and underwent a tensile test. The force that dislodged abutment from implant fixture was recorded. The data were analysed using independent sample t-test, ANOVA and Tukey HSD test. Results Before cyclic loading, removal torque in groups A, B and C were significantly different (B> A> C, P<.05). After cyclic loading, removal torque in all groups decreased significantly (P<.05). Group C revealed significantly less removal torque than groups A and B (P<.005). Tensile force in all groups significantly increased after cyclic loading (P<.05), group A had significantly less tensile force than groups B and C (P<.005). Conclusions Removal torque reduced significantly after cyclic loading. Before cyclic loading, tapered screws maintained more preload than did flat head screws. After cyclic loading, tapered and flat head screws maintained even amounts of preload. The tensile force that dislodged abutment from implant fixture increased immensely after cyclic loading. PMID:28042450
Standardization of noncontact 3D measurement
NASA Astrophysics Data System (ADS)
Takatsuji, Toshiyuki; Osawa, Sonko; Sato, Osamu
2008-08-01
As the global R&D competition is intensified, more speedy measurement instruments are required both in laboratories and production process. In machinery areas, while contact type coordinate measuring machines (CMM) have been widely used, noncontact type CMMs are growing its market share which are capable of measuring enormous number of points at once. Nevertheless, since no industrial standard concerning an accuracy test of noncontact CMMs exists, each manufacturer writes the accuracy of their product according to their own rules, and this situation gives confusion to customers. The working group ISO/TC 213/WG 10 is trying to make a new ISO standard which stipulates an accuracy test of noncontact CMMs. The concept and the situation of discussion of this new standard will be explained. In National Metrology Institute of Japan (NMIJ), we are collecting measurement data which serves as a technical background of the standards together with a consortium formed by users and manufactures. This activity will also be presented.
A Martian PFS average spectrum: Comparison with ISO SWS
NASA Astrophysics Data System (ADS)
Formisano, V.; Encrenaz, T.; Fonti, S.; Giuranna, M.; Grassi, D.; Hirsh, H.; Khatuntsev, I.; Ignatiev, N.; Lellouch, E.; Maturilli, A.; Moroz, V.; Orleanski, P.; Piccioni, G.; Rataj, M.; Saggin, B.; Zasova, L.
2005-08-01
The evaluation of the planetary Fourier spectrometer performance at Mars is presented by comparing an average spectrum with the ISO spectrum published by Lellouch et al. [2000. Planet. Space Sci. 48, 1393.]. First, the average conditions of Mars atmosphere are compared, then the mixing ratios of the major gases are evaluated. Major and minor bands of CO 2 are compared, from the point of view of features characteristics and bands depth. The spectral resolution is also compared using several solar lines. The result indicates that PFS radiance is valid to better than 1% in the wavenumber range 1800-4200 cm -1 for the average spectrum considered (1680 measurements). The PFS monochromatic transfer function generates an overshooting on the left-hand side of strong narrow lines (solar or atmospheric). The spectral resolution of PFS is of the order of 1.3 cm -1 or better. A large number of narrow features to be identified are discovered.
Shrink-wrapped isosurface from cross sectional images
Choi, Y. K.; Hahn, J. K.
2010-01-01
Summary This paper addresses a new surface reconstruction scheme for approximating the isosurface from a set of tomographic cross sectional images. Differently from the novel Marching Cubes (MC) algorithm, our method does not extract the iso-density surface (isosurface) directly from the voxel data but calculates the iso-density point (isopoint) first. After building a coarse initial mesh approximating the ideal isosurface by the cell-boundary representation, it metamorphoses the mesh into the final isosurface by a relaxation scheme, called shrink-wrapping process. Compared with the MC algorithm, our method is robust and does not make any cracks on surface. Furthermore, since it is possible to utilize lots of additional isopoints during the surface reconstruction process by extending the adjacency definition, theoretically the resulting surface can be better in quality than the MC algorithm. According to experiments, it is proved to be very robust and efficient for isosurface reconstruction from cross sectional images. PMID:20703361
Efficient geometric rectification techniques for spectral analysis algorithm
NASA Technical Reports Server (NTRS)
Chang, C. Y.; Pang, S. S.; Curlander, J. C.
1992-01-01
The spectral analysis algorithm is a viable technique for processing synthetic aperture radar (SAR) data in near real time throughput rates by trading the image resolution. One major challenge of the spectral analysis algorithm is that the output image, often referred to as the range-Doppler image, is represented in the iso-range and iso-Doppler lines, a curved grid format. This phenomenon is known to be the fanshape effect. Therefore, resampling is required to convert the range-Doppler image into a rectangular grid format before the individual images can be overlaid together to form seamless multi-look strip imagery. An efficient algorithm for geometric rectification of the range-Doppler image is presented. The proposed algorithm, realized in two one-dimensional resampling steps, takes into consideration the fanshape phenomenon of the range-Doppler image as well as the high squint angle and updates of the cross-track and along-track Doppler parameters. No ground reference points are required.
NASA Technical Reports Server (NTRS)
Binienda, Wieslaw K.; Roberts, Gary D.; Papadopoulos, Demetrios S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model, for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with the increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
NASA Technical Reports Server (NTRS)
Binienda, W. K.; Roberts, G. D.; Papadopoulos, D. S.
1992-01-01
The results of in-plane four-point bend experiments on unidirectionally reinforced composite beams are presented for graphite/epoxy (T300/934) and graphite/polyimide (G30-500/PMR-15) composites. The maximum load and the location of cracks formed during failure were measured for testpieces with fibers oriented at various angles to the beam axis. Since most of the beams failed near one or more of the load points, the strength of the beams was evaluated in terms of a proposed model for the local stress distribution. In this model, an exact solution to the problem of a localized contact force acting on a unidirectionally reinforced half plane is used to describe the local stress field. The stress singularity at the load points is treated in a manner similar to the stress singularity at a crack tip in fracture mechanisms problems. Using this approach, the effect of fiber angle and elastic material properties on the strength of the beam is described in terms of a load intensity factor. For fiber angles less than 45 deg from the beam axis, a single crack is initiated near one of the load points at a critical value of the load intensity factor. The critical load intensity factor decreases with increasing fiber angle. For larger fiber angles, multiple cracks occur at locations both near and away from the load points, and the load intensity factor at failure increases sharply with increasing fiber angle.
A document centric metadata registration tool constructing earth environmental data infrastructure
NASA Astrophysics Data System (ADS)
Ichino, M.; Kinutani, H.; Ono, M.; Shimizu, T.; Yoshikawa, M.; Masuda, K.; Fukuda, K.; Kawamoto, H.
2009-12-01
DIAS (Data Integration and Analysis System) is one of GEOSS activities in Japan. It is also a leading part of the GEOSS task with the same name defined in GEOSS Ten Year Implementation Plan. The main mission of DIAS is to construct data infrastructure that can effectively integrate earth environmental data such as observation data, numerical model outputs, and socio-economic data provided from the fields of climate, water cycle, ecosystem, ocean, biodiversity and agriculture. Some of DIAS's data products are available at the following web site of http://www.jamstec.go.jp/e/medid/dias. Most of earth environmental data commonly have spatial and temporal attributes such as the covering geographic scope or the created date. The metadata standards including these common attributes are published by the geographic information technical committee (TC211) in ISO (the International Organization for Standardization) as specifications of ISO 19115:2003 and 19139:2007. Accordingly, DIAS metadata is developed with basing on ISO/TC211 metadata standards. From the viewpoint of data users, metadata is useful not only for data retrieval and analysis but also for interoperability and information sharing among experts, beginners and nonprofessionals. On the other hand, from the viewpoint of data providers, two problems were pointed out after discussions. One is that data providers prefer to minimize another tasks and spending time for creating metadata. Another is that data providers want to manage and publish documents to explain their data sets more comprehensively. Because of solving these problems, we have been developing a document centric metadata registration tool. The features of our tool are that the generated documents are available instantly and there is no extra cost for data providers to generate metadata. Also, this tool is developed as a Web application. So, this tool does not demand any software for data providers if they have a web-browser. The interface of the tool provides the section titles of the documents and by filling out the content of each section, the documents for the data sets are automatically published in PDF and HTML format. Furthermore, the metadata XML file which is compliant with ISO19115 and ISO19139 is created at the same moment. The generated metadata are managed in the metadata database of the DIAS project, and will be used in various ISO19139 compliant metadata management tools, such as GeoNetwork.
The American Association for Laboratory Accreditation
2011-03-28
ISO / IEC 17025 ...Information Technology A2LA DoD ELAP Program n All labs are assessed to ISO / IEC 17025 :2005 as the base standard. n In addition, the requirements of 2003...n Inspection Body Accreditation ( ISO / IEC 17020) n Proficiency Testing Providers ( ISO / IEC 17043) n Reference Materials Producers ( ISO Guide
Progress in revising and supplementing fundamental optical ISO standards
NASA Astrophysics Data System (ADS)
Schuhmann, Rainer
2017-11-01
This overview reflects the ISO working group activities of ISO/TC 172 Subcommittee 1 during the last years which have resulted in revisions and new ISO standards for optical components. For ISO 10110, ISO 14999 and other standards new surface forms and metrology techniques have been considered, standards about material characteristics have been consolidated, and optical drawings have been updated. Selected examples of new improvements and future work items are given.
The CMMI Product Suite and International Standards
2006-07-01
standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for
2008-07-18
PAs and PLA ISO 15504 and ISO 12207 COBIT EFQM ISO 9001 Improvement Method Elements Change management techniques: IDEAL and Six Sigma...Multimodel Improvement in Practice 12 SEI Webinar Series Northrop Grumman Mission Systems • CMMI, Six Sigma, ISO , KM • ―.. accelerate achievement of Levels...CMMI, ITIL, ISO 9001, P-CMM ―Integrated Quality Mgmt System‖ • ―…development center…reduce[d]...in-process failure costs...5 to 1%...‖ Wipro • ISO
Measuring Operational Resilience Using the CERT(Registered) Resilience Management Model
2010-09-01
such as ISO 27002 [ ISO 2005]) and then measure the implementation and performance of practices contained in the standard. This checklist-based ap...Security techniques – Code of practice for information security management. ISO /IEC 27002 :2005, June 2005. Also known as ISO /IEC 17799:2005. [ ISO 2007...Table 23: ISO 15939 Process Activities and Tasks 54 Table 24: CERT-RMM Measurement and Analysis Process Area Goals and Practices 55 CMU/SEI
Software Assurance Curriculum Project Volume 3: Master of Software Assurance Course Syllabi
2011-07-01
and International Electrotechnical Commission ( ISO /IEC). ISO /IEC 27002 :2005 Information Technology – Security Techniques – Code of Practice for...Compliance and Policy (CP) practice • [ ISO 2008] ISO 27002 Section 15 Research and identify (or develop) an example of policy language that...Microsoft SDL • [Merkow 2010] Chapters 5, 6, 8 • [ ISO 2008] ISO 27002 Sections 12.1-12.5 Identify practices to mitigate selected risks for sample
2012-03-01
ISO / IEC 17025 Inspection Bodies – ISO / IEC 17020 RMPs – ISO Guide 34 (Reference...certify to : ISO 9001 (QMS), ISO 14001 (EMS), TS 16949 (US Automotive) etc. 2 3 DoD QSM 4.2 standard ISO / IEC 17025 :2005 Each has uncertainty...IPV6, NLLAP, NEFAP TRAINING Programs Certification Bodies – ISO / IEC 17021 Accreditation for Management System
[Update to ISO 15189:2012, and future prospects].
Shimoda, Katsuji; Kubono, Katsuo
2014-06-01
ISO (the International Organization for Standardization) is a worldwide federation of national standard bodies (ISO member bodies). The work of preparing international standards is normally carried out through ISO technical committees. ISO 15189 was prepared by Technical Committee ISO/TC 212, clinical laboratory testing, and in vitro diagnostic test systems. This third edition replaces the second edition (ISO 15189:2007), which was technically revised. Medical laboratory services are essential for patient care and, therefore, have to be available to meet the needs of all patients and the clinical personnel responsible for the care of those patients.
NASA Astrophysics Data System (ADS)
Fang, Huaiyang; Lu, Qingshui; Gao, Zhiqiang; Shi, Runhe; Gao, Wei
2013-09-01
China economy has been rapidly increased since 1978. Rapid economic growth led to fast growth of fertilizer and pesticide consumption. A significant portion of fertilizers and pesticides entered the water and caused water quality degradation. At the same time, rapid economic growth also caused more and more point source pollution discharge into the water. Eutrophication has become a major threat to the water bodies. Worsening environment problems forced governments to take measures to control water pollution. We extracted land cover from Landsat TM images; calculated point source pollution with export coefficient method; then SWAT model was run to simulate non-point source pollution. We found that the annual TP loads from industry pollution into rivers are 115.0 t in the entire watershed. Average annual TP loads from each sub-basin ranged from 0 to 189.4 ton. Higher TP loads of each basin from livestock and human living mainly occurs in the areas where they are far from large towns or cities and the TP loads from industry are relatively low. Mean annual TP loads that delivered to the streams was 246.4 tons and the highest TP loads occurred in north part of this area, and the lowest TP loads is mainly distributed in middle part. Therefore, point source pollution has much high proportion in this area and governments should take measures to control point source pollution.
An approach for the regularization of a power flow solution around the maximum loading point
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kataoka, Y.
1992-08-01
In the conventional power flow solution, the boundary conditions are directly specified by active power and reactive power at each node, so that the singular point coincided with the maximum loading point. For this reason, the computations are often disturbed by ill-condition. This paper proposes a new method for getting the wide-range regularity by giving some modifications to the conventional power flow solution method, thereby eliminating the singular point or shifting it to the region with the voltage lower than that of the maximum loading point. Then, the continuous execution of V-P curves including maximum loading point is realized. Themore » efficiency and effectiveness of the method are tested in practical 598-nodes system in comparison with the conventional method.« less
Developement of watershed and reference loads for a TMDL in Charleston Harbor System, SC.
Silong Lu; Devenra Amatya; Jamie Miller
2005-01-01
It is essential to determine point and non-point source loads and their distribution for development of a dissolved oxygen (DO) Total Maximum Daily Load (TMDL). A series of models were developed to assess sources of oxygen-demand loadings in Charleston Harbor, South Carolina. These oxygen-demand loadings included nutrients and BOD. Stream flow and nutrient...
Maintenance of equilibrium point control during an unexpectedly loaded rapid limb movement.
Simmons, R W; Richardson, C
1984-06-08
Two experiments investigated whether the equilibrium point hypothesis or the mass-spring model of motor control subserves positioning accuracy during spring loaded, rapid, bi-articulated movement. For intact preparations, the equilibrium point hypothesis predicts response accuracy to be determined by a mixture of afferent and efferent information, whereas the mass-spring model predicts positioning to be under a direct control system. Subjects completed a series of load-resisted training trials to a spatial target. The magnitude of a sustained spring load was unexpectedly increased on selected trials. Results indicated positioning accuracy and applied force varied with increases in load, which suggests that the original efferent commands are modified by afferent information during the movement as predicted by the equilibrium point hypothesis.
Alkazemi, Dalal; Jackson, Robert L; Chan, Hing Man; Kubow, Stan
2016-09-01
F3-isoprostanes (F3-IsoPs), derived from peroxidation of eicosapentaenoic acid (C20:5n-3), could be cardioprotective by limiting production of F2-isoprostanes (F2-IsoPs), a cardiovascular disease risk factor. The objective of the study was to determine whether the n-3-polyunsaturated (PUFA)-rich Inuit diet is associated with a lower plasma ratio of F2-IsoPs to F3-IsoPs. This was a cross-sectional observational study. The study was conducted in 36 Canadian Arctic Inuit communities. Participants included a random subset (n = 233) of Inuit adults taken from a population-based survey. Plasma F2-IsoPs and F3-IsoPs, cardiometabolic risk factors (blood lipids, C-reactive protein, blood pressure, fasting glucose) and markers of dietary exposure (erythrocyte n-3 and n-6 PUFA, blood levels of Se, mercury, polychlorinated biphenyls) were measured. Inuit aged 40 years old and older vs younger Inuit showed higher concentrations of plasma F3-IsoPs and erythrocyte n-3 PUFA and lower plasma F2-IsoPs concentrations despite having higher blood lipids, fasting glucose, systolic blood pressure, and percentage body fat. Plasma F3-IsoPs were not associated with any cardiometabolic measures. When subjects were categorized into tertiles according to total n-3 PUFA erythrocyte concentrations, F3-IsoPs increased with increasing tertiles, whereas the F2-IsoP to F3-IsoP ratio was lowest at the highest n-3 tertile. The F2-IsoP to F3-IsoP ratio was significantly predicted by C20:5n-3 (β= -.365, P = .002); C20:4n-6:C20:5n-3 (β = .056, P = .006), blood mercury (β = -.812, P =.015), blood Se (β = -1.95, P = .015), and smoking (β = .745, P = .025). Plasma F3-IsoPs were not associated with cardiometabolic risk factors previously seen with F2-IsoPs. Higher n-3 fatty acid status was associated with lower plasma F2-IsoPs and higher plasma F3-IsoPs, which provides partial explanation to the cardioprotective effects of the n-3 PUFA-rich Inuit diet.
Abdulmajeed, Aous A; Närhi, Timo O; Vallittu, Pekka K; Lassila, Lippo V
2011-04-01
This study was designed to evaluate the effect of an increase of fiber-density on some mechanical properties of higher volume fiber-reinforced composite (FRC). Five groups of FRC with increased fiber-density were fabricated and two additional groups were prepared by adding silanated barium-silicate glass fillers (0.7 μm) to the FRC. The unidirectional E-glass fiber rovings were impregnated with light-polymerizable bisGMA-TEGDMA (50-50%) resin. The fibers were pulled through a cylindrical mold with an opening diameter of 4.2mm, light cured for 40s and post-cured at elevated temperature. The cylindrical specimens (n=12) were conditioned at room temperature for 2 days before testing with the three-point bending test (Lloyd Instruments Ltd.) adapted to ISO 10477. Fiber-density was analyzed by combustion and gravimetric analyzes. ANOVA analysis revealed that by increasing the vol.% fraction of E-glass fibers from 51.7% to 61.7% there was a change of 27% (p<0.05) in the modulus of elasticity, 34% (p<0.05) in the toughness, and 15% (p<0.05) in the load bearing capacity, while there was only 8% (p<0.05) increase in the flexural strength although it was statistically insignificant. The addition of particulate fillers did not improve the mechanical properties. This study showed that the properties of FRC could be improved by increasing fibervolume fraction. Modulus of elasticity, toughness, and load bearing capacity seem to follow the law of ratio of quantity of fibers and volume of the polymer matrix more precisely than flexural strength when high fiber-density is used. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Isolevuglandin adducts in disease.
Salomon, Robert G; Bi, Wenzhao
2015-06-20
A diverse family of lipid-derived levulinaldehydes, isolevuglandins (isoLGs), is produced by rearrangement of endoperoxide intermediates generated through both cyclooxygenase (COX) and free radical-induced cyclooxygenation of polyunsaturated fatty acids and their phospholipid esters. The formation and reactions of isoLGs with other biomolecules has been linked to alcoholic liver disease, Alzheimer's disease, age-related macular degeneration, atherosclerosis, cardiac arythmias, cancer, end-stage renal disease, glaucoma, inflammation of allergies and infection, mitochondrial dysfunction, multiple sclerosis, and thrombosis. This review chronicles progress in understanding the chemistry of isoLGs, detecting their production in vivo and understanding their biological consequences. IsoLGs have never been isolated from biological sources, because they form adducts with primary amino groups of other biomolecules within seconds. Chemical synthesis enabled investigation of isoLG chemistry and detection of isoLG adducts present in vivo. The first peptide mapping and sequencing of an isoLG-modified protein present in human retina identified the modification of a specific lysyl residue of the sterol C27-hydroxylase Cyp27A1. This residue is preferentially modified by iso[4]LGE2 in vitro, causing loss of function. Adduction of less than one equivalent of isoLG can induce COX-associated oligomerization of the amyloid peptide Aβ1-42. Adduction of isoLGE2 to phosphatidylethanolamines causes gain of function, converting them into proinflammatory isoLGE2-PE agonists that foster monocyte adhesion to endothelial cells. Among the remaining questions on the biochemistry of isoLGs are the dependence of biological activity on isoLG isomer structure, the structures and mechanism of isoLG-derived protein-protein and DNA-protein cross-link formation, and its biological consequences.
ASSIP Study of Real-Time Safety-Critical Embedded Software-Intensive System Engineering Practices
2008-02-01
and assessment 2. product engineering processes 3. tooling processes 6 | CMU/SEI-2008-SR-001 Slide 1 Process Standards IEC/ ISO 12207 Software...and technical effort to align with 12207 IEC/ ISO 15026 System & Software Integrity Levels Generic Safety SAE ARP 4754 Certification Considerations...Process Frameworks in revision – ISO 9001, ISO 9004 – ISO 15288/ ISO 12207 harmonization – RTCA DO-178B, MOD Standard UK 00-56/3, … • Methods & Tools
ANSI-ASQ National Accreditation Board /ACLASS
2011-03-28
unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Laboratories – ISO / IEC 17025 Inspection...Bodies – ISO / IEC 17020 RMPs – ISO Guide 34 (Reference Materials) PT Providers – ISO 17043 Product Certifiers – ISO Guide 65 Government...Programs: DoD ELAP, EPA Energy Star, CPSC Toy Safety, NRC, NIST IPV6, NLLAP, NEFAP TRAINING Programs Certification Bodies – ISO / IEC 17021
Benchmarking Software Assurance Implementation
2011-05-18
product The chicken#. (a.k.a. Process Focused Assessment ) – Management Systems ( ISO 9001, ISO 27001 , ISO 2000) – Capability Maturity Models (CMMI...Assurance PRM, RMM, Assurance for CMMI)) – Lifecycle Processes ( ISO /IEEE 15288, ISO /IEEE 12207) – COBIT, ITIL, MS SDL, OSAMM, BSIMM 5 The egg...a.k.a Product Focused Assessments) – SCAP - NIST-SCAP – ISO /OMG W3C – KDM, BPMN, RIF, XMI, RDF – OWASP Top 10 – SANS TOP 25 – Secure Code Check Lists
Xu, Hua-Shan; Xu, Zong-Xue; Liu, Pin
2013-03-01
One of the key techniques in establishing and implementing TMDL (total maximum daily load) is to utilize hydrological model to quantify non-point source pollutant loads, establish BMPs scenarios, reduce non-point source pollutant loads. Non-point source pollutant loads under different years (wet, normal and dry year) were estimated by using SWAT model in the Zhangweinan River basin, spatial distribution characteristics of non-point source pollutant loads were analyzed on the basis of the simulation result. During wet years, total nitrogen (TN) and total phosphorus (TP) accounted for 0.07% and 27.24% of the total non-point source pollutant loads, respectively. Spatially, agricultural and residential land with steep slope are the regions that contribute more non-point source pollutant loads in the basin. Compared to non-point source pollutant loads with those during the baseline period, 47 BMPs scenarios were set to simulate the reduction efficiency of different BMPs scenarios for 5 kinds of pollutants (organic nitrogen, organic phosphorus, nitrate nitrogen, dissolved phosphorus and mineral phosphorus) in 8 prior controlled subbasins. Constructing vegetation type ditch was optimized as the best measure to reduce TN and TP by comparing cost-effective relationship among different BMPs scenarios, and the costs of unit pollutant reduction are 16.11-151.28 yuan x kg(-1) for TN, and 100-862.77 yuan x kg(-1) for TP, which is the most cost-effective measure among the 47 BMPs scenarios. The results could provide a scientific basis and technical support for environmental protection and sustainable utilization of water resources in the Zhangweinan River basin.
Vertical load capacities of roof truss cross members.
Gearhart, David F; Morsy, Mohamed Khaled
2016-05-01
Trusses used for roof support in coal mines are constructed of two grouted bolts installed at opposing forty-five degree angles into the roof and a cross member that ties the angled bolts together. The load on the cross member is vertical, which is transverse to the longitudinal axis, and therefore the cross member is loaded in the weakest direction. Laboratory tests were conducted to determine the vertical load capacity and deflection of three different types of cross members. Single-point load tests, with the load applied in the center of the specimen and double-point load tests, with a span of 2.4 m, were conducted. For the single-point load configuration, the yield of the 25 mm solid bar cross member was nominally 98 kN of vertical load, achieved at 42 cm of deflection. For cable cross members, yield was not achieved even after 45 cm of deflection. Peak vertical loads were about 89 kN for 17 mm cables and 67 kN for the 15 mm cables. For the double-point load configurations, the 25 mm solid bar cross members yielded at 150 kN of vertical load and 25 cm of deflection. At 25 cm of deflection individual cable strands started breaking at 133 and 111 kN of vertical load for the 17 and 15 mm cable cross members respectively.
75 FR 29530 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
...: ER07-397-005. Applicants: ISO New England Inc. and New England Power Pool. Description: ISO New England Inc et. al submit revision to Section III.13 of the ISO Tariff in response to the compliance... Independent System Operator Corporation submits amendments to the ISO's amendment to the ISO Tariff filed on 3...
Pushing, pulling and manoeuvring an industrial cart: a psychophysiological study.
Giagloglou, Evanthia; Radenkovic, Milan; Brankovic, Sasa; Antoniou, Panagiotis; Zivanovic-Macuzic, Ivana
2017-09-18
One of the most frequent manual occupational tasks involves the pushing and pulling of a cart. Although several studies have associated health risks with pushing and pulling, the effects are not clear since occupational tasks have social, cognitive and physical components. The present work investigates a real case of a pushing and pulling occupational task from a manufacturing company. The study initially characterizes the case in accordance with Standard No. ISO 11228-2:2007 as low risk. An experiment with 14 individuals during three modalities of pushing and pulling was performed in order to further investigate the task with the application of electrophysiology. At the end, a simple questionnaire was given. The results show electrophysiological differences among the three modalities of pushing and pulling, with a major difference between action with no load and fully loaded with a full range of motions on the cart to handle.
Hydroisomerization of n-dodecane over Pt/Al-MCM-48 catalysts.
Yun, Soyoung; Park, Young-Kwon; Jeong, Soon-Yong; Han, Jeongsik; Jeon, Jong-Ki
2014-04-01
The objective of this study is to evaluate the catalytic potential of Pt/Al-MCM-48 catalysts in hydroisomerization of n-dodecane. The effects of the Si/Al ratio and platinum loading on the acid characteristics of Al-MCM-48 and the catalytic performance in n-dodecane hydroisomerization were analyzed. The catalysts were characterized by X-ray diffraction, nitrogen adsorption, infrared spectroscopy of pyridine adsorption, and temperature programmed desorption of ammonia. The number of weak strength acid sites on Al-MCM-48 increased with 0.5 wt% platinum loading. The weak strength acid sites of Pt/Al-MCM-48 catalysts were ascribed to Lewis acid sites, which can be confirmed by NH3-TPD and FTIR spectra of pyridine adsorption. Iso-dodecane can be produced with high selectivity in n-dodecane hydrosisomerization over Pt/Al-MCM-48 catalysts. This is attributed to the mild acidic properties of Pt/Al-MCM-48 catalysts.
Probabilistic safety assessment of the design of a tall buildings under the extreme load
DOE Office of Scientific and Technical Information (OSTI.GOV)
Králik, Juraj, E-mail: juraj.kralik@stuba.sk
2016-06-08
The paper describes some experiences from the deterministic and probabilistic analysis of the safety of the tall building structure. There are presented the methods and requirements of Eurocode EN 1990, standard ISO 2394 and JCSS. The uncertainties of the model and resistance of the structures are considered using the simulation methods. The MONTE CARLO, LHS and RSM probabilistic methods are compared with the deterministic results. On the example of the probability analysis of the safety of the tall buildings is demonstrated the effectiveness of the probability design of structures using Finite Element Methods.
1973-06-01
nm.ddt. inital, Diet n*Mf) Thomas L. Wachtel, M.D. G. R. McCahan, Jr., D.V.M. 0 REPORT CATS 70. TOTAL No. Or PAGE Nb O. or mrs June 1973 - w 78 0. CON...observations of caloric uptake of pigskin, rise in temperature at the dermis-fat interface as a function of both time and skin surface temperature and an...of Iso-, Hypo - and Hypertonic Sodium Solutions in the Treatment of Burn Shock in Mice," Surgery, 57: 698-704, May 1965. 24. Rosenthal, S. M
Probabilistic safety assessment of the design of a tall buildings under the extreme load
NASA Astrophysics Data System (ADS)
Králik, Juraj
2016-06-01
The paper describes some experiences from the deterministic and probabilistic analysis of the safety of the tall building structure. There are presented the methods and requirements of Eurocode EN 1990, standard ISO 2394 and JCSS. The uncertainties of the model and resistance of the structures are considered using the simulation methods. The MONTE CARLO, LHS and RSM probabilistic methods are compared with the deterministic results. On the example of the probability analysis of the safety of the tall buildings is demonstrated the effectiveness of the probability design of structures using Finite Element Methods.
Fire suppression system of a small-scale LNG loading facility at PT Badak NGL
NASA Astrophysics Data System (ADS)
Yustiarza, Farhan Hilmyawan
2017-03-01
LNG progressively become favorable energy to replace oil-based fuel due to lower cost and more environment-friendly. In order to support an emerging LNG demands in Kalimantan, PT Badak NGL, one of the leading LNG Company in the world, develops the land-transported LNG loading facility. This facility performs loading the LNG into a small-scale tank (ISO Tank) with 20 m3 capacities. Safety reviews over this facility were conducted. Based on these reviews, the LNG filling station requires supplemental safeguards, such as LNG spill containment and firefighting foam system besides firewater system and dry chemical system. The spill containment provides holding LNG spill within the limits of plant property, while the high expansion foam system deals to minimize the vaporization rate to prevent a fire incident. This paper mainly discusses designing of such supplemental safeguards. The requirement of the spill containment is 20 m3 (6.3 × 3.3 × 2.0) m and the foam system should be capable generating foam at least 40 m3/min.
Yang, Dong; Zhu, Xiangcheng; Wu, Xueyun; Feng, Zhiyang; Huang, Lei; Shen, Ben; Xu, Zhinan
2011-01-01
iso-Migrastatin (iso-MGS) has been actively pursued recently as an outstanding candidate of antimetastasis agents. Having characterized the iso-MGS biosynthetic gene cluster from its native producer Streptomyces platensis NRRL 18993, we have recently succeeded in producing iso-MGS in five selected heterologous Streptomyces hosts, albeit the low titers failed to meet expectations and cast doubt on the utility of this novel technique for large-scale production. To further explore and capitalize on the production capacity of these hosts, a thorough investigation of these five engineered strains with three fermentation media for iso-MGS production was undertaken. Streptomyces albus J1074 and Streptomyces lividans K4-114 were found to be preferred heterologous hosts, and subsequent analysis of carbon and nitrogen sources revealed that sucrose and yeast extract were ideal for iso-MGS production. After the initial optimization, the titers of iso-MGS in all five hosts were considerably improved by 3–18-fold in the optimized R2YE medium. Furthermore, the iso-MGS titer of S. albus J1074 (pBS11001) was significantly improved to 186.7 mg/L by a hybrid medium strategy. Addition of NaHCO3 to the latter finally afforded an optimized iso-MGS titer of 213.8 mg/L, about 5-fold higher than the originally reported system. With S. albus J1074 (pBS11001) as a model host, the expression of iso-MGS gene cluster in four different media was systematically studied via the quantitative RT–PCR technology. The resultant comparison revealed the correlation of gene expression and iso-MGS production for the first time; synchronous expression of the whole gene cluster was crucial for optimal iso-MGS production. These results reveal new insights into the iso-MGS biosynthetic machinery in heterologous hosts and provide the primary data to realize large-scale production of iso-MGS for further preclinical studies. PMID:21132287
Results of the performance verification of the CoaguChek XS system.
Plesch, W; Wolf, T; Breitenbeck, N; Dikkeschei, L D; Cervero, A; Perez, P L; van den Besselaar, A M H P
2008-01-01
This is the first paper reporting a performance verification study of a point-of-care (POC) monitor for prothrombin time (PT) testing according to the requirements given in chapter 8 of the International Organization for Standardization (ISO) 17593:2007 standard "Clinical laboratory testing and in vitro medical devices - Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy". The monitor under investigation was the new CoaguChek XS system which is designed for use in patient self testing. Its detection principle is based on the amperometric measurement of the thrombin activity generated by starting the coagulation cascade using a recombinant human thromboplastin. The system performance verification study was performed at four study centers using venous and capillary blood samples on two test strip lots. Laboratory testing was performed from corresponding frozen plasma samples with six commercial thromboplastins. Samples from 73 normal donors and 297 patients on oral anticoagulation therapy were collected. Results were assessed using a refined data set of 260 subjects according to the ISO 17593:2007 standard. Each of the two test strip lots met the acceptance criteria of ISO 17593:2007 versus all thromboplastins (bias -0.19 to 0.18 INR; >97% of data within accuracy limits). The coefficient of variation for imprecision of the PT determinations in INR ranged from 2.0% to 3.2% in venous, and from 2.9% to 4.0% in capillary blood testing. Capillary versus venous INR data showed agreement of results with regression lines equal to the line of identity. The new system demonstrated a high level of trueness and accuracy, and low imprecision in INR testing. It can be concluded that the CoaguChek XS system complies with the requirements in chapter 8 of the ISO standard 17593:2007.
Synthesis, characterization and evaluation of a fluorinated resin monomer with low water sorption.
Liu, Xue; Wang, Zengyao; Zhao, Chengji; Bu, Wenhuan; Zhang, Yurong; Na, Hui
2018-01-01
A fluorinated acrylate monomer (4-TF-PQEA) without BPA (bisphenol-A) structure was synthesized and mixed with triethylene glycol dimethacrylate (TEGDMA) to used as dental resin system in order to achieve lower water sorption and reduce human exposure to BPA derivatives. Double bond conversion (DC) was measured using Fourier transform infrared spectroscopy (FTIR). Water sorption (WS), water solution (WL) and depth of cure (DOC) were evaluated according to ISO 4049:2009. Water contact angle (CA) was measured using contact angle analyzer. Polymerization shrinkage (PS) was evaluated according to the Archimedes' principle and ISO 17304:2013. Flexural strength (FS) and flexural modulus (FM) were measured by three-point bending test with a universal testing machine according to ISO 4049:2009. Comprehensive strength (CS) and vickers microhardness (VM) were also investigated. Thermal stability test was measure by Thermogravimetric analyzer. Cytotoxicity of three resin systems was tested through MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromid) cytotoxicity method according to the ISO 10993-5:2009. Bisphenol-A glycidyl dimethacrylate (Bis-GMA)/ TEGDMA resin system was used as a control. The results show that 4-TF-PQEA/TEGDMA resin system had lower PS, lower WS and higher DC values than those of Bis-GMA/TEGDMA resin system except some mechanical properties, such as FS, FM and CS. Moreover, properties of other 4-TF-PQEA-containing resin systems were also comparable with those of Bis-GMA/TEGDMA resin system. In particular, the overall performance of resin system consisted of 4-TF-PQEA/Bis-GMA/TEGDMA is optimized when the mixture ratio is 30/40/30(wt/wt/wt). Therefore, the 4-TF-PQEA has potential to be used as resin monomer for dental resin composites to achieve lower water sorption. Copyright © 2017 Elsevier Ltd. All rights reserved.
Varzakas, Theodoros H
2011-09-01
The Failure Mode and Effect Analysis (FMEA) model has been applied for the risk assessment of pastry processing. A tentative approach of FMEA application to the pastry industry was attempted in conjunction with ISO22000. Preliminary Hazard Analysis was used to analyze and predict the occurring failure modes in a food chain system (pastry processing plant), based on the functions, characteristics, and/or interactions of the ingredients or the processes, upon which the system depends. Critical Control points have been identified and implemented in the cause and effect diagram (also known as Ishikawa, tree diagram, and fishbone diagram). In this work a comparison of ISO22000 analysis with HACCP is carried out over pastry processing and packaging. However, the main emphasis was put on the quantification of risk assessment by determining the Risk Priority Number (RPN) per identified processing hazard. Storage of raw materials and storage of final products at -18°C followed by freezing were the processes identified as the ones with the highest RPN (225, 225, and 144 respectively) and corrective actions were undertaken. Following the application of corrective actions, a second calculation of RPN values was carried out leading to considerably lower values (below the upper acceptable limit of 130). It is noteworthy that the application of Ishikawa (Cause and Effect or Tree diagram) led to converging results thus corroborating the validity of conclusions derived from risk assessment and FMEA. Therefore, the incorporation of FMEA analysis within the ISO22000 system of a pastry processing industry is considered imperative.
2009-02-01
management, available at <http://www.iso.org/ iso /en/CatalogueDetailPage.CatalogueDetail?CSNUMBER=39612&ICS1=35&ICS2=40 &ICS3=>. ISO /IEC 27001 . Information...Management of the Systems Engineering Process. [ ISO /IEC 27001 ] ISO /IEC 27001 :2005. Information technology -- Security techniques -- Information security...software life cycles [ ISO /IEC 15026]. Software assurance is a key element of national security and homeland security. It is critical because dramatic
A method to approximate a closest loadability limit using multiple load flow solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yorino, Naoto; Harada, Shigemi; Cheng, Haozhong
A new method is proposed to approximate a closest loadability limit (CLL), or closest saddle node bifurcation point, using a pair of multiple load flow solutions. More strictly, the obtainable points by the method are the stationary points including not only CLL but also farthest and saddle points. An operating solution and a low voltage load flow solution are used to efficiently estimate the node injections at a CLL as well as the left and right eigenvectors corresponding to the zero eigenvalue of the load flow Jacobian. They can be used in monitoring loadability margin, in identification of weak spotsmore » in a power system and in the examination of an optimal control against voltage collapse. Most of the computation time of the proposed method is taken in calculating the load flow solution pair. The remaining computation time is less than that of an ordinary load flow.« less
Tracy, J.C.; Bernknopf, R.; Forney, W.; Hill, K.
2004-01-01
The Federal Clean Water Act (Section 303(d)) mandates that states develop Total Maximum Daily Load (TMDL) plans for water bodies that are on the Section 303(d) list. To be placed on the 303(d) list, a water body must be found to have water quality conditions that limit its ability to meet its designated beneficial uses. The TMDL for a water body is defined in 40 CFR 130 as the sum of waste load allocations from identified points sources and non-point sources within the water body's watershed. The TMDL plan for a listed water body should identify the current waste loads to the water body, the waste load capacity of the water body and then allocate the waste load capacity to the known point and non-point sources of pollution within the water body's watershed. Copyright 2004 ASCE.
Park, Sun Young; Son, Beung Gu; Park, Young Hoon; Kim, Cheol-Min; Park, Geuntae; Choi, Young-Whan
2014-09-01
As a part of ongoing studies to elucidate pharmacologically active components of Schisandra chinensis, we isolated and studied α-iso-cubebene. The neuroprotective mechanisms of α-iso-cubebene in human neuroblastoma SH-SY5Y cells were investigated. α-Iso-cubebene significantly inhibited cytotoxicity and apoptosis due to 6-hydroxydopamine (6-OHDA)-induced neurotoxicity in dopaminergic SH-SY5Y cells. Pretreatment of cells with α-iso-cubebene reduced intracellular accumulation of ROS and calcium in response to 6-OHDA. The neuroprotective effects of α-iso-cubebene were found to result from protecting the mitochondrial membrane potential. Notably, α-iso-cubebene inhibited the release of apoptosis-inducing factor from the mitochondria into the cytosol and nucleus after 6-OHDA treatment. α-Iso-cubebene also induced the activation of PKA/PKB/CREB/Nrf2 and suppressed 6-OHDA-induced neurotoxicity. α-Iso-cubebene was found to induce phosphorylation of PKA and PKB and activate Nrf2 and CREB signaling pathways in a dose-dependent manner. Additionally, α-iso-cubebene stimulated the expression of the antioxidant response genes NQO1 and HO-1. Finally, α-iso-cubebene-mediated neuroprotective effects were found to be reversible after transfection with CREB and Nrf2 small interfering RNAs.
NASA Astrophysics Data System (ADS)
Wang, J.; Xin, L. P.; Qiu, Y. L.; Xu, D. W.; Wei, J. Y.
2018-03-01
By using the line ratio C IV λ1549/C II λ1335 as a tracer of the ionization ratio of the interstellar medium (ISM) illuminated by a long gamma-ray burst (LGRB), we identify a global photoionization response of the ionization ratio to the photon luminosity of the prompt emission assessed by either L iso/E peak or {L}iso}/{E}peak}2. The ionization ratio increases with both L iso/E peak and L iso/E 2 peak for a majority of the LGRBs in our sample, although there are a few outliers. The identified dependence of C IV/C II on {L}iso}/{E}peak}2 suggests that the scatter of the widely accepted Amati relation is related to the ionization ratio in the ISM. The outliers tend to have relatively high C IV/C II values as well as relatively high C IV λ1549/Si IV λ1403 ratios, which suggests an existence of Wolf–Rayet stars in the environment of these LGRBs. We finally argue that the outliers and the LGRBs following the identified C IV/C II‑L iso/E peak ({L}iso}/{E}peak}2) correlation might come from different progenitors with different local environments.
75 FR 8321 - Notice of Attendance at Nepool Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... meeting information, see http://www.iso-ne.com/committees/comm_wkgrps/index.html . The discussions at each.... ER07-397, ISO New England Inc. and the New England Power Pool Participants Committee Docket No. ER08-633, ISO New England Inc. Docket No. ER08-830, ISO New England Inc. Docket No. ER08-1209, ISO New...
CMMI(Registered) for Development, Version 1.3
2010-11-01
ISO /IEC 15288:2008 Systems and Software Engineering – System Life Cycle Processes [ ISO 2008b] ISO /IEC 27001 :2005 Information technology – Security...IEC 2005 International Organization for Standardization and International Electrotechnical Commission. ISO /IEC 27001 Information Technology...International Electrotechnical Commission ( ISO /IEC) body of standards. CMMs focus on improving processes in an organization. They contain the
CMMI(Registered) for Services, Version 1.3
2010-11-01
ISO 2008b] ISO /IEC 27001 :2005 Information technology – Security techniques – Information Security Management Systems – Requirements [ ISO /IEC 2005...Commission. ISO /IEC 27001 Information Technology – Security Techniques – Information Security Management Systems – Requirements, 2005. http...CMM or International Organization for Standardization ( ISO ) 9001, you will immediately recognize many similarities in their structure and content
75 FR 7581 - RTO/ISO Performance Metrics; Notice Requesting Comments on RTO/ISO Performance Metrics
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-22
... performance communicate about the benefits of RTOs and, where appropriate, (2) changes that need to be made to... of staff from all the jurisdictional ISOs/RTOs to develop a set of performance metrics that the ISOs/RTOs will use to report annually to the Commission. Commission staff and representatives from the ISOs...
Implementing the DoD Joint Operation Planning Process for Private Industry Enterprise Security
2011-09-01
Standards Organization’s ( ISO ) ISO 27001 ( ISO 27002 defines the controls), and the IT Service Management Forum’s Information Technology Infrastructure...27001 certification. 24 Alberto Bastos and Rosangela Caubit, ISO 27001 and 27002 : Information...includes: 90,000 records lost from Booz Allen Hamilton; 90,000,000 26 ISO /IEC 27002 , 19 December
Ni, Yongnian; Wei, Min; Kokot, Serge
2011-11-01
Interaction of isoprenaline (ISO) with calf-thymus DNA was studied by spectroscopic and electrochemical methods. The behavior of ISO was investigated at a glassy carbon electrode (GCE) by cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV); ISO was oxidized and an irreversible oxidation peak was observed. The binding constant K and the stoichiometric coefficient m of ISO with DNA were evaluated. Also, with the addition of DNA, hyperchromicity of the UV-vis absorption spectra of ISO was noted, while the fluorescence intensity decreased significantly. Multivariate curve resolution-alternating least squares (MCR-ALS) chemometrics method was applied to resolve the combined spectroscopic data matrix, which was obtained by the UV-vis and fluorescence methods. Pure spectra of ISO, DNA and ISO-DNA complex, and their concentration profiles were then successfully obtained. The results indicated that the ISO molecule intercalated into the base-pairs of DNA, and the complex of ISO-DNA was formed. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kizu, Takio, E-mail: KIZU.Takio@nims.go.jp, E-mail: TSUKAGOSHI.Kazuhito@nims.go.jp; Tsukagoshi, Kazuhito, E-mail: KIZU.Takio@nims.go.jp, E-mail: TSUKAGOSHI.Kazuhito@nims.go.jp; Aikawa, Shinya
We fabricated homogeneous double-layer amorphous Si-doped indium oxide (ISO) thin-film transistors (TFTs) with an insulating ISO cap layer on top of a semiconducting ISO bottom channel layer. The homogeneously stacked ISO TFT exhibited high mobility (19.6 cm{sup 2}/V s) and normally-off characteristics after annealing in air. It exhibited normally-off characteristics because the ISO insulator suppressed oxygen desorption, which suppressed the formation of oxygen vacancies (V{sub O}) in the semiconducting ISO. Furthermore, we investigated the recovery of the double-layer ISO TFT, after a large negative shift in turn-on voltage caused by hydrogen annealing, by treating it with annealing in ozone. The recoverymore » in turn-on voltage indicates that the dense V{sub O} in the semiconducting ISO can be partially filled through the insulator ISO. Controlling molecule penetration in the homogeneous double layer is useful for adjusting the properties of TFTs in advanced oxide electronics.« less
NASA Astrophysics Data System (ADS)
Li, Ting
2014-05-01
This paper analyzes Intraseasonal Oscillation (ISO) features and inter-annual differences of the South China Sea (SCS) Summer Monsoon (SCSSM), evolution of its Low Frequency (LF) circulation and convection fields and precipitation anomalies, and path of ISO propagation, as well as impact of MJO in tropical Indian Ocean on SCSSM ISO during 1979-2008. It is found that (1) The SCSSM ISO goes through six phases (exclusive of the weak phase) at every complete fluctuation: developing, strongest, weakening, restraining, weakest and recovering phase. Due to tropical LF convection propagating eastward and northward, the LF convection and circulation in the 1st-3rd and 4th-6th phases present the anti-phase in the Arabian Sea-West Pacific zonal band. Its corresponding rainy bands also present anti-phase roughly. The rainy band moves eastward with LF convection mainly in tropical regions in the south of 20° N, while moves northward in East Asia subtropical regions in the north of 20° N. (2) The SCSSM ISO intensity presents significant inter-annual difference. There are three stronger ISO in the stronger SCSSM ISO years. The first two oscillations propagates from the tropical Indian Ocean to the Bay of Bengal firstly, and then to SCS along the 10° -20° N zonal direction, stimulates the ISO to propagate to South China, forming a relay propagation path in meridional-zonal direction. Moreover, in the weaker SCSSM ISO years, the ISO weakens greatly and irregularly. In averaged conditions, the ISO propagates from tropical Indian Ocean to the SCS by about 20 days (one half ISO periods). (3) MJO1 (the first modal of MJO index provided by the Climate Prediction Center) averaged value in the 1st-2nd pentads of April has the negative correlation with the SCSSM ISO intensity. When MJO in tropical Indian Ocean is more active in the 1st-2nd pentads of April, it is stronger in the subsequent May to August, and the ISO also propagates strongly to the SCS, so that the SCSSM ISO strengthens. Conversely, the SCSSM ISO weakens. The abnormal MJO in the 1st-2nd pentads of April contributes to a certain theory basis to predict the subsequent SCSSM ISO intensity and analyze the abnormal rainfall in related regions.
Noise evaluation of a point autofocus surface topography measuring instrument
NASA Astrophysics Data System (ADS)
Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard
2018-06-01
In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.
Fujimoto, Kazumitsu; Asai, Noriaki; Nakajima, Yoshinaga; Inoue, Kaoru
2015-11-01
Our laboratory, for the purpose of Quality Management System (QMS) improvement, acquired ISO 15189:2003 accreditation 9 years ago and completed the renewal to ISO 15189:2012 last year. In this study, we reviewed the efficacy of ISO 15189 based on an analysis of laboratory director's and managers' opinions. We could realize QMS improvement through the proactive implementation of preventive and corrective actions, and also the continuous implementation of education and delivery by means of reviewing the interview records of ISO 15189:2012 renewal with the laboratory director. All answers to the questionnaire obtained from managers with regard to the advantages of ISO 15189 acquisition agreed with the purpose of ISO 15189. From these results, we concluded that ISO 15189 acquisition was successful for QMS improvement. [Review].
Wireless power charging using point of load controlled high frequency power converters
Miller, John M.; Campbell, Steven L.; Chambon, Paul H.; Seiber, Larry E.; White, Clifford P.
2015-10-13
An apparatus for wirelessly charging a battery of an electric vehicle is provided with a point of load control. The apparatus includes a base unit for generating a direct current (DC) voltage. The base unit is regulated by a power level controller. One or more point of load converters can be connected to the base unit by a conductor, with each point of load converter comprising a control signal generator that transmits a signal to the power level controller. The output power level of the DC voltage provided by the base unit is controlled by power level controller such that the power level is sufficient to power all active load converters when commanded to do so by any of the active controllers, without generating excessive power that may be otherwise wasted.
Diaw, Corinne Stadelmann; Piol, Nicolas; Urfer, Jocelyne; Werner, Dominique; Roth-Kleiner, Matthias
2013-10-21
Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology. © 2013.
Nanoscale Roughness and Morphology Affect the IsoElectric Point of Titania Surfaces
Borghi, Francesca; Vyas, Varun; Podestà, Alessandro; Milani, Paolo
2013-01-01
We report on the systematic investigation of the role of surface nanoscale roughness and morphology on the charging behaviour of nanostructured titania (TiO2) surfaces in aqueous solutions. IsoElectric Points (IEPs) of surfaces have been characterized by direct measurement of the electrostatic double layer interactions between titania surfaces and the micrometer-sized spherical silica probe of an atomic force microscope in NaCl aqueous electrolyte. The use of a colloidal probe provides well-defined interaction geometry and allows effectively probing the overall effect of nanoscale morphology. By using supersonic cluster beam deposition to fabricate nanostructured titania films, we achieved a quantitative control over the surface morphological parameters. We performed a systematical exploration of the electrical double layer properties in different interaction regimes characterized by different ratios of characteristic nanometric lengths of the system: the surface rms roughness Rq, the correlation length ξ and the Debye length λD. We observed a remarkable reduction by several pH units of IEP on rough nanostructured surfaces, with respect to flat crystalline rutile TiO2. In order to explain the observed behavior of IEP, we consider the roughness-induced self-overlap of the electrical double layers as a potential source of deviation from the trend expected for flat surfaces. PMID:23874708
A Strategy for Improved System Assurance
2007-06-20
Quality (Measurements Life Cycle Safety, Security & Others) ISO /IEC 12207 * Software Life Cycle Processes ISO 9001 Quality Management System...14598 Software Product Evaluation Related ISO /IEC 90003 Guidelines for the Application of ISO 9001:2000 to Computer Software IEEE 12207 Industry...Implementation of International Standard ISO /IEC 12207 IEEE 1220 Standard for Application and Management of the System Engineering Process Use in
Isoguanine and 5-Methyl-Isocytosine Bases, In Vitro and In Vivo
Bande, Omprakash; Abu El Asrar, Rania; Braddick, Darren; Dumbre, Shrinivas; Pezo, Valérie; Schepers, Guy; Pinheiro, Vitor B; Lescrinier, Eveline; Holliger, Philipp; Marlière, Philippe; Herdewijn, Piet
2015-01-01
The synthesis, base-pairing properties and in vitro and in vivo characteristics of 5-methyl-isocytosine (isoCMe) and isoguanine (isoG) nucleosides, incorporated in an HNA(h) (hexitol nucleic acid)–DNA(d) mosaic backbone, are described. The required h-isoG phosphoramidite was prepared by a selective deamination as a key step. As demonstrated by Tm measurements the hexitol sugar showed slightly better mismatch discrimination against dT. The d-isoG base mispairing follows the order T>G>C while the h-isoG base mispairing follows the order G>C>T. The h- and d-isoCMe bases mainly mispair with G. Enzymatic incorporation experiments show that the hexitol backbone has a variable effect on selectivity. In the enzymatic assays, isoG misincorporates mainly with T, and isoCMe misincorporates mainly with A. Further analysis in vivo confirmed the patterns of base-pair interpretation for the deoxyribose and hexitol isoCMe/isoG bases in a cellular context, through incorporation of the bases into plasmidic DNA. Results in vivo demonstrated that mispairing and misincorporation was dependent on the backbone scaffold of the base, which indicates rational advances towards orthogonality. PMID:25684598
van 't Erve, Thomas J; Lih, Fred B; Kadiiska, Maria B; Deterding, Leesa J; Mason, Ronald P
2018-02-01
It is widely accepted that free radicals in tobacco smoke lead to oxidative stress and generate the popular lipid peroxidation biomarker 8-iso-prostaglandin F 2α (8-iso-PGF 2α ). However, 8-iso-PGF 2α can simultaneously be produced in vivo by the prostaglandin-endoperoxide synthases (PGHS) induced by inflammation. This inflammation-dependent mechanism has never been considered as a source of elevated 8-iso-PGF 2α in tobacco smokers. The goal of this study is to quantify the distribution of chemical- and PGHS-dependent 8-iso-PGF 2α formation in the plasma of tobacco smokers and non-smokers. The influences of gender and hormonal contraceptive use were accounted for. The distribution was determined by measuring the 8-iso-PGF 2α /prostaglandin F 2α (PGF 2α ) ratio. When comparing smokers (n = 28) against non-smokers (n = 30), there was a statistically significant increase in the 8-iso-PGF 2α concentration. The source of this increased 8-iso-PGF 2α was primarily from PGHS. When stratifying for gender, the increase in 8-iso-PGF 2α in male smokers (n = 9) was primarily from PGHS. Interestingly, female smokers on hormonal contraceptives had increased 8-iso-PGF 2α in both pathways, whereas those not on hormonal contraceptives did not have increased 8-iso-PGF 2α . In conclusion, increased plasma 8-iso-PGF 2α in tobacco smokers has complex origins, with PGHS-dependent formation as the primary source. Accounting for both pathways provides a definitive measurement of both oxidative stress and inflammation. Published by Elsevier Inc.
Choi, Jae-Won; Choi, Kyung-Hee; Chae, Hee-Jin; Chae, Sung-Ki; Bae, Eun-Bin; Lee, Jin-Ju; Lee, So-Hyoun; Jeong, Chang-Mo; Huh, Jung-Bo
2018-04-06
The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH), internal-octagon connection (IO), internal-hexagon connection (IH), one-body implant (OB), micro-locking implant system (ML). The maximum compressive load was measured using a universal testing machine (UTM) according to the ISO 14801. Retention was evaluated in two experiments: (1) a tensile test of the structure modifications of the components (attachment and implant) and (2) a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz). The load-bearing capacity of the ML group was not significantly different from the other groups ( p > 0.05). The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention ( p > 0.05), but the shape of the retentive groove in the implant post had a statistically significant effect on retention ( p < 0.05). On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.
Choi, Kyung-Hee; Chae, Hee-Jin; Chae, Sung-Ki; Bae, Eun-Bin; Lee, Jin-Ju; Lee, So-Hyoun; Jeong, Chang-Mo; Huh, Jung-Bo
2018-01-01
The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH), internal-octagon connection (IO), internal-hexagon connection (IH), one-body implant (OB), micro-locking implant system (ML). The maximum compressive load was measured using a universal testing machine (UTM) according to the ISO 14801. Retention was evaluated in two experiments: (1) a tensile test of the structure modifications of the components (attachment and implant) and (2) a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz). The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05). The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05), but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05). On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice. PMID:29642407
Farinango, Charic D; Benavides, Juan S; Cerón, Jesús D; López, Diego M; Álvarez, Rosa E
2018-01-01
Background Previous studies have demonstrated the effectiveness of information and communication technologies to support healthy lifestyle interventions. In particular, personal health record systems (PHR-Ss) empower self-care, essential to support lifestyle changes. Approaches such as the user-centered design (UCD), which is already a standard within the software industry (ISO 9241-210:2010), provide specifications and guidelines to guarantee user acceptance and quality of eHealth systems. However, no single PHR-S for metabolic syndrome (MS) developed following the recommendations of the ISO 9241-210:2010 specification has been found in the literature. Objective The aim of this study was to describe the development of a PHR-S for the management of MS according to the principles and recommendations of the ISO 9241-210 standard. Methods The proposed PHR-S was developed using a formal software development process which, in addition to the traditional activities of any software process, included the principles and recommendations of the ISO 9241-210 standard. To gather user information, a survey sample of 1,187 individuals, eight interviews, and a focus group with seven people were performed. Throughout five iterations, three prototypes were built. Potential users of each system evaluated each prototype. The quality attributes of efficiency, effectiveness, and user satisfaction were assessed using metrics defined in the ISO/IEC 25022 standard. Results The following results were obtained: 1) a technology profile from 1,187 individuals at risk for MS from the city of Popayan, Colombia, identifying that 75.2% of the people use the Internet and 51% had a smartphone; 2) a PHR-S to manage MS developed (the PHR-S has the following five main functionalities: record the five MS risk factors, share these measures with health care professionals, and three educational modules on nutrition, stress management, and a physical activity); and 3) usability tests on each prototype obtaining the following results: 100% effectiveness, 100% efficiency, and 84.2 points in the system usability scale. Conclusion The software development methodology used was based on the ISO 9241-210 standard, which allowed the development team to maintain a focus on user’s needs and requirements throughout the project, which resulted in an increased satisfaction and acceptance of the system. Additionally, the establishment of a multidisciplinary team allowed the application of considerations not only from the disciplines of software engineering and health sciences but also from other disciplines such as graphical design and media communication. Finally, usability testing allowed the observation of flaws in the designs, which helped to improve the solution. PMID:29386903
Plasma 8-iso-Prostaglandin F2α, a possible prognostic marker in aneurysmal subarachnoid hemorrhage.
Pan, De-Sheng; Yan, Min; Hassan, Muhammad; Fang, Ze-Bin; Chen, Man-Tao
2017-06-01
8-iso-Prostaglandin F2α (8-iso-PGF2α) is a potential biomarker of oxidative stress. This study clarified whether plasma 8-iso-PGF2α concentrations were affected and its underlying relevance to prognosis in aneurysmal subarachnoid hemorrhage (aSAH). In this prospective, observational study, a total of 170 controls and 170 aSAH patients were enrolled. Plasma 8-iso-PGF2α concentrations were detected using an ELISA. Severity was assessed by World Federation of Neurological Surgeons (WFNS) scale and modified Fisher grading scale. Clinical outcomes included 6-month mortality and poor outcome referred to as Glasgow outcome scale score of 1-3. As compared to controls, admission plasma 8-iso-PGF2α concentrations were significantly enhanced. Increased concentrations of plasma 8-iso-PGF2α correlated with WFNS scores and modified Fisher scores. 8-iso-PGF2α in plasma was an independent predictor for clinical outcomes. Under ROC curve, the predictive values of 8-iso-PGF2α concentrations resembled those of WFNS scores and modified Fisher scores for clinical outcomes. An elevation in plasma 8-iso-PGF2α concentrations is associated with the severity and poor outcome after aSAH, substantializing 8-iso-PGF2α as a potential prognostic biomarker of aSAH. Copyright © 2017. Published by Elsevier B.V.
Saied, Nashwa Mostafa; Hamza, Alaaeldin Ahmed
2014-09-01
Isotretinoin (Iso) is a widely used retinoid for the treatment of dermatologic conditions. Although it has broad side effects, there is no well-designed study about preventive effects against its hepatic toxicity. This study was undertaken to evaluate the protective effect of selenium (Se) against Iso-induced hepatotoxicity in Wistar rats. Animals were divided into four groups. The first group served as control. The second, third and fourth groups received Se, Iso and Se & Iso, respectively, for 28 days. Se was administered daily orally at a dose of 50 µg / 100 g body weight. Iso was given daily orally at a dose of 0.75 mg/ 100 g /day in olive oil. Iso caused significant increases in serum levels of alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, cholesterol, triglycerides, and high-density lipids content. Animals also showed significant rise in thiobarbituric acid reacting substance and nitric oxide content with concomitant decrease in reduced glutathione content and the antioxidant enzyme activities of superoxide dismutase and catalase in liver tissue after Iso exposure. Se administration produced a significant protection against the hepatotoxic effects of Iso and markedly alleviated alterations in these parameters. The results obtained herein clearly indicate that Iso causes induction of oxidative stress and the co-administration of Iso and Se provides protection against Iso-induced liver injury.
Simultaneous measurement of passage through the restriction point and MCM loading in single cells
Håland, T. W.; Boye, E.; Stokke, T.; Grallert, B.; Syljuåsen, R. G.
2015-01-01
Passage through the Retinoblastoma protein (RB1)-dependent restriction point and the loading of minichromosome maintenance proteins (MCMs) are two crucial events in G1-phase that help maintain genome integrity. Deregulation of these processes can cause uncontrolled proliferation and cancer development. Both events have been extensively characterized individually, but their relative timing and inter-dependence remain less clear. Here, we describe a novel method to simultaneously measure MCM loading and passage through the restriction point. We exploit that the RB1 protein is anchored in G1-phase but is released when hyper-phosphorylated at the restriction point. After extracting cells with salt and detergent before fixation we can simultaneously measure, by flow cytometry, the loading of MCMs onto chromatin and RB1 binding to determine the order of the two events in individual cells. We have used this method to examine the relative timing of the two events in human cells. Whereas in BJ fibroblasts released from G0-phase MCM loading started mainly after the restriction point, in a significant fraction of exponentially growing BJ and U2OS osteosarcoma cells MCMs were loaded in G1-phase with RB1 anchored, demonstrating that MCM loading can also start before the restriction point. These results were supported by measurements in synchronized U2OS cells. PMID:26250117
2011-09-01
ISO / IEC 17025 :2005, NADCAP Acuren...River Road Brackenridge, PA 250 (724) 224-1000 $4.8B 11,000 ISO -9001, AS- 9100, NADCAP, ISO / IEC 17025 ATI – Allegheny Ludlum (Houston, PA) 501...Western Ave Houston, PA 233 (724) 745-2000 $4.8B 11,000 ISO -9001, AS- 9100, NADCAP, ISO / IEC 17025 ATI – Allegheny Ludlum (Louisville, OH)
An investigation of preload relaxation behaviour of three zinc- aluminum alloys
NASA Astrophysics Data System (ADS)
Mir, A. A.
2016-08-01
Zinc alloy castings are usually assembled together or mounted by screwed steel fasteners, and are tightened to a predetermined torque to develop the required tensile preload in the fastener. Due to relaxation processes in the castings, creep may cause a partial preload loss at an elevated temperature. The equipment used for load relaxation tests consists of a loadmonitoring device, an oil bath, and a data-acquisition system. A load cell monitoring device is used to monitor the load loss in an ISO-metric M6*1 steel screw set into sand castings made from alloys No. 3, No. 5 and No. 2 and tightened to produce an initial preload of 6 kN. The castings were held at constant temperature in the range 80 - 120°C in an oil bath. The oil bath maintains the desired test temperature throughout the experiment. All tests were conducted for periods of up to 160 h. For all alloys, the initial load loss was high, decreasing gradually with time, but not ceasing. The load loss increased rapidly with test temperature, and almost all of the relaxation curves approximated to a logarithmic decay of load with time. Alloy No. 2 had the best resistance to load loss, with No. 5 next and No. 3 worst at all temperatures. The lower resistance to relaxation of alloy No. 3 was mainly due to the lower relaxation strength of copper-free primary dendrites, whereas in alloys No. 5 and No. 2, the higher copper contents contribute greatly to their relaxation strength in the form of second-phase particles.
Chung, Shan Shan; Fryxell, Gerald E; Lo, Carlos W H
2005-04-01
For decades, industry has been the main source of pollution in China. Determined to make changes, the mainland Chinese authorities have decided to promote mechanisms that incorporate environmental concerns into the internal management of enterprises. This is manifested in the rapid adoption of the ISO14000 standards, including a significant increase in ISO14001 registrations in China. Thus, this study examined the environmental policy statements of 106 certified facilities in mainland China against a strict interpretation of the mandatory requirements of the ISO 14001:1996 standard and the nonmandatory ISO14004 requirements in order to shed some light on the implementation of environmental management systems in an emerging economic giant. It was decided to analyze the environmental policy statement because such a statement is a core element in the ISO system of environmental management of each facility and there are relatively clear and specific requirements on what an environmental policy statement shall include. An analysis of the contents of the environmental policy statements shows that conformance to the relevant requirements of both the mandatory ISO14001 standard and the nonmandatory ISO14004 standard is far from impressive and that the facilities in our sample seldom went beyond the minimum requirements. By using ISO14001 and ISO14004 conformance scores as the dependent variables, we found that conformity to ISO14001 and overall conformance to ISO14000 series can be explained to some extent by the degree of top management commitment, the experience with informal environmental management systems, and the form of ownership of the facilities.
NASA Astrophysics Data System (ADS)
Pokorný, Jan; Kopečková, Barbora; Fišer, Jan; JÍcha, Miroslav
2018-06-01
The aim of the paper is to assemble a simulator for evaluation of thermal comfort in car cabins in order to give a feedback to the HVAC (heating, ventilation and air conditioning) system. The HW (hardware) part of simulator is formed by thermal manikin Newton and RH (relative humidity), velocity and temperature probes. The SW (software) part consists of the Thermal Comfort Analyser (using ISO 14505-2) and Virtual Testing Stand of Car Cabin defining the heat loads of car cabin. Simulator can provide recommendation for the climate control how to improve thermal comfort in cabin by distribution and directing of air flow, and also by amount of ventilation power to keep optimal temperature inside a cabin. The methods of evaluation of thermal comfort were verified by tests with 10 test subjects for summer (summer clothing, ambient air temperature 30 °C, HVAC setup: +24 °C auto) and winter conditions (winter clothing, ambient air temperature -5 °C, HVAC setup: +18 °C auto). The tests confirmed the validity of the thermal comfort evaluation using the thermal manikin and ISO 14505-2.
Duan, Yuanyuan; Gonzalez, Jorge A; Kulkarni, Pratim A; Nagy, William W; Griggs, Jason A
2018-06-16
To validate the fatigue lifetime of a reduced-diameter dental implant system predicted by three-dimensional finite element analysis (FEA) by testing physical implant specimens using an accelerated lifetime testing (ALT) strategy with the apparatus specified by ISO 14801. A commercially-available reduced-diameter titanium dental implant system (Straumann Standard Plus NN) was digitized using a micro-CT scanner. Axial slices were processed using an interactive medical image processing software (Mimics) to create 3D models. FEA analysis was performed in ABAQUS, and fatigue lifetime was predicted using fe-safe ® software. The same implant specimens (n=15) were tested at a frequency of 2Hz on load frames using apparatus specified by ISO 14801 and ALT. Multiple step-stress load profiles with various aggressiveness were used to improve testing efficiency. Fatigue lifetime statistics of physical specimens were estimated in a reliability analysis software (ALTA PRO). Fractured specimens were examined using SEM with fractographic technique to determine the failure mode. FEA predicted lifetime was within the 95% confidence interval of lifetime estimated by experimental results, which suggested that FEA prediction was accurate for this implant system. The highest probability of failure was located at the root of the implant body screw thread adjacent to the simulated bone level, which also agreed with the failure origin in physical specimens. Fatigue lifetime predictions based on finite element modeling could yield similar results in lieu of physical testing, allowing the use of virtual testing in the early stages of future research projects on implant fatigue. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
Contributors to dietary glycaemic index and glycaemic load in the Netherlands: the role of beer.
Sluik, Diewertje; Atkinson, Fiona S; Brand-Miller, Jennie C; Fogelholm, Mikael; Raben, Anne; Feskens, Edith J M
2016-04-14
Diets high in glycaemic index (GI) and glycaemic load (GL) have been associated with a higher diabetes risk. Beer explained a large proportion of variation in GI in a Finnish and an American study. However, few beers have been tested according to International Organization for Standardization (ISO) methodology. We tested the GI of beer and estimated its contribution to dietary GI and GL in the Netherlands. GI testing of pilsner beer (Pilsner Urquell) was conducted at The University of Sydney according to ISO international standards with glucose as the reference food. Subsequently, GI and GL values were assigned to 2556 food items in the 2011 Dutch food composition table using a six-step methodology and consulting four databases. This table was linked to dietary data from 2106 adults in the Dutch National Food Consumption Survey 2007-2010. Stepwise linear regression identified contribution to inter-individual variation in dietary GI and GL. The GI of pilsner beer was 89 (SD 5). Beer consumption contributed to 9·6 and 5·3% inter-individual variation in GI and GL, respectively. Other foods that contributed to the inter-individual variation in GI and GL included potatoes, bread, soft drinks, sugar, candy, wine, coffee and tea. The results were more pronounced in men than in women. In conclusion, beer is a high-GI food. Despite its relatively low carbohydrate content (approximately 4-5 g/100 ml), it still made a contribution to dietary GL, especially in men. Next to potatoes, bread, sugar and sugar-sweetened beverages, beer captured a considerable proportion of between-person variability in GI and GL in the Dutch diet.
Macrophage Migration Inhibitory Factor Enzymatic Activity, Lung Inflammation, and Cystic Fibrosis
Adamali, Huzaifa; Armstrong, Michelle E.; McLaughlin, Anne Marie; Cooke, Gordon; McKone, Edward; Costello, Christine M.; Gallagher, Charles G.; Leng, Lin; Baugh, John A.; Fingerle-Rowson, Günter; Bucala, Richard J.; McLoughlin, Paul
2012-01-01
Rationale: Macrophage migration inhibitory factor (MIF) is a proinflammatory mediator with unique tautomerase enzymatic activity; the precise function has not been clearly defined. We previously demonstrated that individual patients with cystic fibrosis (CF) who are genetically predisposed to be high MIF producers develop accelerated end-organ injury. Objectives: To characterize the effects of the MIF-CATT polymorphism in patients with CF ex vivo. To investigate the role of MIF’s tautomerase activity in a murine model of Pseudomonas aeruginosa infection. Methods: MIF and tumor necrosis factor (TNF)-α protein levels were assessed in plasma or peripheral blood mononuclear cell (PBMC) supernatants by ELISA. A murine pulmonary model of chronic Pseudomonas infection was used in MIF wild-type mice (mif+/+) and in tautomerase-null, MIF gene knockin mice (mif P1G/P1G). Measurements and Main Results: MIF protein was measured in plasma and PBMCs from 5- and 6-CATT patients with CF; LPS-induced TNF-α production from PBMCs was also assessed. The effect of a specific inhibitor of MIF-tautomerase activity, ISO-1, was investigated in PBMCs. In the murine infection model, total weight loss, differential cell counts, bacterial load, and intraacinar airspace/tissue volume were measured. MIF and TNF-α levels were increased in 6-CATT compared with 5-CATT patients with CF. LPS-induced TNF-α production from PBMCs was attenuated in the presence of ISO-1. In a murine model of Pseudomonas infection, significantly less pulmonary inflammation and bacterial load was observed in mifP1G/P1G compared with mif+/+ mice. Conclusions: MIF-tautomerase activity may provide a novel therapeutic target in patients with chronic inflammatory diseases such as CF, particularly those patients who are genetically predisposed to produce increased levels of this cytokine. PMID:22592805
Studies on the application of temperature-responsive ion exchange polymers with whey proteins.
Maharjan, Pankaj; Campi, Eva M; De Silva, Kirthi; Woonton, Brad W; Jackson, W Roy; Hearn, Milton T W
2016-03-18
Several new types of temperature-responsive ion exchange resins of different polymer composition have been prepared by grafting the products from the co-polymerisation of N-phenylacrylamide, N-iso-propylacrylamide and acrylic acid derivatives onto cross-linked agarose. Analysis of the binding isotherms for these different resins obtained under batch adsorption conditions indicated that the resin based on N-iso-propylacrylamide containing 5% (w/w) N-phenylacrylamide and 5% (w/w) acrylic acid resulted in the highest adsorption capacity, Bmax, for the whey protein, bovine lactoferrin, e.g. 14 mg bovine lactoferrin/mL resin at 4 °C and 62 mg bovine lactoferrin/mL resin at 40 °C, respectively. Under dynamic loading conditions at 40 °C, 94% of the loaded bovine lactoferrin on a normalised mg protein per mL resin basis was adsorbed by this new temperature-responsive ion-exchanger, and 76% was eluted by a single cycle temperature shift to 4 °C without varying the composition of the 10mM sodium dihydrogen phosphate buffer, pH 6.5, or the flow rate. The binding characteristics of these different ion exchange resins with bovine lactoferrin were also compared to results obtained using other resins based on N-isopropylacrylamide but contained N-tert-butylacrylamide rather than N-phenylacrylamide, where the corresponding dynamic capture and release properties for bovine lactoferrin required different temperature conditions of 20 °C and 50 °C, respectively for optimal desorption/adsorption. The cationic protein, bovine lactoperoxidase, was also adsorbed and desorbed with these temperature-responsive resins under similar conditions of changing temperature, whereas the anionic protein, bovine β-lactoglobulin, was not adsorbed under this regime of temperature conditions but instead eluted in the flow-through. Copyright © 2016 Elsevier B.V. All rights reserved.
Magwedere, Kudakwashe; Rauff, Dionne; De Klerk, Grietjie; Keddy, Karen H; Dziva, Francis
2015-11-01
Nontyphoidal salmonellosis continues to pose a global threat to human health, primarily by causing food-borne illnesses, and food-producing animals are the principal reservoirs of many pathogenic serovars. To identify key control points and generate information that may enable future estimation of the transmission routes between the environment, animals, and humans, we examined data on Salmonella isolates in South Africa. Samples were obtained from livestock and poultry on farms, meat at abattoirs, raw materials at feed mills, animal feed, and environmental sources (eg, poultry houses, abattoirs, feed mills, water) from 2012 to 2014 in compliance with each establishment's protocols conforming to International Organization for Standardization (ISO) (ISO/TS 17728, ISO 18593:2004 and ISO 17604:2003) standards. Isolation and serotyping of Salmonella were performed according to the scope of accreditation of the respective laboratories conforming to ISO/IEC 17025:2005 standard techniques. Salmonella was isolated from 9031 of 180 298 (5.0%) samples, and these isolates were distributed among 188 different serovars. Salmonella Enteritidis was the most frequent isolate, with 1944 of 180 298 (21.5%) originating from poultry on farms, poultry meat, and poultry houses, followed by Salmonella Havana, with 677 of 180 298 (7.5%), mostly from environmental samples. Serovars that are uncommonly associated with human disease (Salmonella Idikan, Salmonella Salford, and Salmonella Brancaster) were isolated at higher frequencies than Salmonella Typhimurium, a common cause of human illness. Environmental samples accounted for 3869 of 9031 (42.8%) samples positive for Salmonella. We describe the frequent isolation of Salmonella of a wide variety of serovars, from an array of animal feeds, food animals, and food animal environment. As prevention of human salmonellosis requires the effective control of Salmonella in food animals, these data can be used to facilitate Salmonella control in food animals and thereby prevent human infections. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
First Results from the ISO-IRAS Faint Galaxy Survey
NASA Astrophysics Data System (ADS)
Levine, Deborah A.; Lonsdale, Carol J.; Hurt, Robert L.; Smith, Harding E.; Helou, George; Beichman, Charles; Cesarsky, Catherine; Elbaz, David; Klaas, Ulrich; Laureijs, Rene; Lemke, Detrich; Lord, Steven; McMahon, Richard; Moshir, Mehrdad; Neugebauer, Gerry; Soifer, B. T.; Van Buren, Dave; Wehrle, Ann; Wolstencroft, Ray
1998-09-01
We present the first results from the ISO-IRAS Faint Galaxy Survey (IIFGS), a program designed to obtain ISO observations of the most distant and luminous galaxies in the IRAS Faint Source Survey by filling short gaps in the ISO observing schedule with pairs of 12 μm ISOCAM and 90 μm ISOPHOT observations. As of 1997 October, over 500 sources have been observed, with an ISOCAM detection rate over 80%, covering over 1.25 deg2 of sky to an 11.5 μm point-source completeness limit of approximately 1.0 mJy (corresponding to a ~10 σ detection sensitivity). Observations are presented for nine sources detected by ISOPHOT and ISOCAM early in the survey for which we have ground-based G- and I-band images and optical spectroscopy. The ground-based data confirm that the IIFGS strategy efficiently detects moderate-redshift (z = 0.11-0.38 for this small sample) strong emission line galaxies with L60 μm >~ 1011 L⊙ one of our sample has L60 μm > 1012 L⊙ (H0 = 75 km s-1 Mpc-1, Ω = 1). The infrared-optical spectral energy distributions are comparable to those of nearby luminous infrared galaxies, which span the range from pure starburst (e.g., Arp 220) to infrared QSO (Mrk 231). Two of the systems show signs of strong interaction, and four show active galactic nucleus (AGN)-like excitation; one of the AGNs, F15390+6038, which shows a high excitation Seyfert 2 spectrum, has an unusually warm far- to mid-infrared color and may be an obscured QSO. The IIFGS sample is one of the largest and deepest samples of infrared-luminous galaxies available, promising to be a rich sample for studying infrared-luminous galaxies up to z ~ 1 and for understanding the evolution of infrared galaxies and the star formation rate in the universe. ISO is an ESA project with instruments funded by ESA member states (especially the PI countries: France, Germany, the Netherlands, and the United Kingdom) and with the participation of ISAS and NASA.
Fernandes, Richard; Carey, Conn; Hynes, James; Papkovsky, Dmitri
2013-01-01
The importance of food safety has resulted in a demand for a more rapid, high-throughput method for total viable count (TVC). The industry standard for TVC determination (ISO 4833:2003) is widely used but presents users with some drawbacks. The method is materials- and labor-intensive, requiring multiple agar plates per sample. More importantly, the method is slow, with 72 h typically required for a definitive result. Luxcel Biosciences has developed the GreenLight Model 960, a microtiter plate-based assay providing a rapid high-throughput method of aerobic bacterial load assessment through analysis of microbial oxygen consumption. Results are generated in 1-12 h, depending on microbial load. The mix and measure procedure allows rapid detection of microbial oxygen consumption and equates oxygen consumption to microbial load (CFU/g), providing a simple, sensitive means of assessing the microbial contamination levels in foods (1). As bacteria in the test sample grow and respire, they deplete O2, which is detected as an increase in the GreenLight probe signal above the baseline level (2). The time required to reach this increase in signal can be used to calculate the CFU/g of the original sample, based on a predetermined calibration. The higher the initial microbial load, the earlier this threshold is reached (1).
A Model for Joint Software Reviews
1998-10-01
CEPMAN 1, 1996; Gabb, 1997], and with the growing popularity of outsourcing, they are becoming more important in the commercial sector [ ISO /IEC 12207 ...technical and management reviews [MIL-STD-498, 1996; ISO /IEC 12207 , 1995]. Management reviews occur after technical reviews, and are focused on the cost...characteristics, Standard (No. ISO /IEC 9126-1). [ ISO /IEC 12207 , 1995] Information Technology Software Life Cycle Processes, Standard (No. ISO /IEC 12207
ERIC Educational Resources Information Center
Byrum, John D.
This paper describes two international standards for the representation of the names of languages. The first (ISO 639-1), published in 1988, provides two-letter codes for 136 languages and was produced primarily to meet terminological needs. The second (ISO 639-2) appeared in late 1998 and includes three-letter codes for 460 languages. This list…
2002-02-01
NVLAP procedures are compatible with, among others, the most recent official publications of ISO / IEC 17025 (formally ISO / IEC Guide 25), ISO Guides 2, 30... IEC Guide 17025 and the relevant requirements of ISO 9002-1994. NVLAP Handbook 150-20 contains information that is specific to Common Criteria...Evaluation Technical Report EAP Evaluation Acceptance Package IEC International Electrotechnical Commission ISO International
The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!
Mooijman, Kirsten A
2018-05-01
Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.
An assessment model for quality management
NASA Astrophysics Data System (ADS)
Völcker, Chr.; Cass, A.; Dorling, A.; Zilioli, P.; Secchi, P.
2002-07-01
SYNSPACE together with InterSPICE and Alenia Spazio is developing an assessment method to determine the capability of an organisation in the area of quality management. The method, sponsored by the European Space Agency (ESA), is called S9kS (SPiCE- 9000 for SPACE). S9kS is based on ISO 9001:2000 with additions from the quality standards issued by the European Committee for Space Standardization (ECSS) and ISO 15504 - Process Assessments. The result is a reference model that supports the expansion of the generic process assessment framework provided by ISO 15504 to nonsoftware areas. In order to be compliant with ISO 15504, requirements from ISO 9001 and ECSS-Q-20 and Q-20-09 have been turned into process definitions in terms of Purpose and Outcomes, supported by a list of detailed indicators such as Practices, Work Products and Work Product Characteristics. In coordination with this project, the capability dimension of ISO 15504 has been revised to be consistent with ISO 9001. As contributions from ISO 9001 and the space quality assurance standards are separable, the stripped down version S9k offers organisations in all industries an assessment model based solely on ISO 9001, and is therefore interesting to all organisations, which intend to improve their quality management system based on ISO 9001.
Optimization of Nanowire-Resistance Load Logic Inverter.
Hashim, Yasir; Sidek, Othman
2015-09-01
This study is the first to demonstrate characteristics optimization of nanowire resistance load inverter. Noise margins and inflection voltage of transfer characteristics are used as limiting factors in this optimization. Results indicate that optimization depends on resistance value. Increasing of load resistor tends to increasing in noise margins until saturation point, increasing load resistor after this point will not improve noise margins significantly.
Neuroprotective effects of α-iso-cubebenol on glutamate-induced neurotoxicity.
Park, Sun Young; Choi, Yung Hyun; Park, Geuntae; Choi, Young-Whan
2015-09-01
α-Iso-cubebenol is a natural compound isolated from Schisandra chinensis, and is reported to have beneficial bioactivity including anti-inflammatory and anti-tumor activities. Glutamate-induced oxidative neuronal damage has been implicated in a variety of neurodegenerative disorders. Here we investigated the mechanisms of α-iso-cubebenol protection of mouse hippocampus-derived neuronal cells (HT22 cells) from apoptotic cell death induced by the major excitatory neurotransmitter, glutamate. Pretreatment with α-iso-cubebenol markedly attenuated glutamate-induced loss of cell viability and release of lactate dehydrogenase), in a dose-dependent manner. α-Iso-cubebenol significantly reduced glutamate-induced intracellular reactive oxygen species and calcium accumulation. Strikingly, α-iso-cubebenol inhibited glutamate-induced mitochondrial depolarization, which releases apoptosis-inducing factor from mitochondria. α-Iso-cubebenol also suppressed glutamate-induced phosphorylation of extracellular-signal-regulated kinases. Furthermore, α-iso-cubebenol induced CREB phosphorylation and Nrf-2 nuclear accumulation and increased the promoter activity of ARE and CREB in HT22 cells. α-Iso-cubebenol also upregulated the expression of phase-II detoxifying/antioxidant enzymes such as HO-1 and NQO1. Subsequent studies revealed that the inhibitory effects of α-iso-cubebenol on glutamate-induced apoptosis were abolished by small interfering RNA-mediated knockdown of CREB and Nrf-2. These findings suggest that α-iso-cubebenol prevents excitotoxin-induced oxidative damage to neurons by inhibiting apoptotic cell death, and might be a potential preventive or therapeutic agent for neurodegenerative disorders. Copyright © 2015 Elsevier B.V. All rights reserved.
Engineering of CRISPR/Cas9-mediated potyvirus resistance in transgene-free Arabidopsis plants.
Pyott, Douglas E; Sheehan, Emma; Molnar, Attila
2016-10-01
Members of the eukaryotic translation initiation factor (eIF) gene family, including eIF4E and its paralogue eIF(iso)4E, have previously been identified as recessive resistance alleles against various potyviruses in a range of different hosts. However, the identification and introgression of these alleles into important crop species is often limited. In this study, we utilise CRISPR/Cas9 technology to introduce sequence-specific deleterious point mutations at the eIF(iso)4E locus in Arabidopsis thaliana to successfully engineer complete resistance to Turnip mosaic virus (TuMV), a major pathogen in field-grown vegetable crops. By segregating the induced mutation from the CRISPR/Cas9 transgene, we outline a framework for the production of heritable, homozygous mutations in the transgene-free T2 generation in self-pollinating species. Analysis of dry weights and flowering times for four independent T3 lines revealed no differences from wild-type plants under standard growth conditions, suggesting that homozygous mutations in eIF(iso)4E do not affect plant vigour. Thus, the established CRISPR/Cas9 technology provides a new approach for the generation of Potyvirus resistance alleles in important crops without the use of persistent transgenes. © 2016 The Authors. Molecular Plant Pathology Published by British Society for Plant Pathology and John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Wright, Kenneth H.; Schneider, Todd; Vaughn, Jason; Hoang, Bao; Funderburk, Victor V.; Wong, Frankie; Gardiner, George
2010-01-01
A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.
Lorenzen, J; Habermann, C; Utler, C; Grzyska, U; Weber, C; Adam, G; Koops, A
2009-10-01
To evaluate the changes in academic quality indicators after implementation of a quality management system according to DIN ISO 9001:2000. After implementation and certification of a quality management system, the actual state based on quality indicators from the fields of student teaching, research, continuing education and the satisfaction of referring physician was determined. After implementation of an action plan for the individual areas, the temporal changes in the ratios were documented in the follow-up. The evaluation of teaching performance obtained by questionnaire among the students of the radiology course showed a steady increase in satisfaction (mean value 2003: 2.7; 2007: 3.9). In the field of research an increase in scientific output was achieved based on the number of an internal publication score (2002: 99 points; 2006: 509). Repeated opinion surveys among our referring physicians found improvements in indicators for the appointment of investigations, consulting service and waiting times for the investigation, while the waiting times for internal transport service did not improve. Exemplary measurements of the success of the advanced training of the staff demonstrated the need for continuing education for quality improvement. The evaluation of quality indicators showed over time a measurable positive impact on processes of a radiological University Hospital after implementation of a QM system according to DIN ISO 9001:2000. Georg Thieme Verlag KG Stuttgart-New York.
Clinical evaluation of the anaesthetic sparing effect of brachial plexus block in cats.
Mosing, Martina; Reich, Heidi; Moens, Yves
2010-03-01
To evaluate the isoflurane sparing effect and the post-surgical analgesia provided by a brachial plexus block (BPB) in cats undergoing distal thoracic limb surgery. Prospective randomized blinded clinical study. Twenty client-owned cats. Cats were assigned to receive either no BPB (group NB) or a nerve stimulator guided BPB (group BPB) using lidocaine (3.6 mg kg(-1)) and bupivacaine (1.2 mg kg(-1)). Pre-medication consisted of midazolam and ketamine intravenously (IV). Anaesthesia was induced with propofol IV to effect and maintained with isoflurane delivered in oxygen and a continuous rate infusion of fentanyl (2 microg kg(-1) hour(-1)). End-tidal isoflurane concentration (Fe'ISO) was adjusted every 3 minutes guided by changes in cardiorespiratory parameters and reflexes present, to maintain a stable depth of anaesthesia. Five time points were chosen to record all parameters and compare values between groups. Recovery and post-operative pain assessment were performed using a visual analogue scale (VAS) at 15 and 45 minutes after extubation and thereafter at hourly intervals until 5 hours after placement of the BPB. No clinically significant differences were seen for heart rate, respiratory rate and non-invasive blood pressure between groups. Mean Fe'ISO was significantly lower in group BPB compared with group NB at all time points. In group NB, all intraoperative measurements of Fe'ISO were significantly higher compared with baseline (3 minutes before start of surgery) measurements. During recovery, VAS scores for group BPB were significantly lower than for group NB. Additional analgesics were needed in all cats within the study period. In cats undergoing orthopaedic surgery of the thoracic limb, BPB reduced intra-operative isoflurane requirement and pain during the early post-operative period when compared with procedures without a BPB. BPB is a useful adjunct to anaesthesia in such cases.
Assessment of New Load Schedules for the Machine Calibration of a Force Balance
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Gisler, R.; Kew, R.
2015-01-01
New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.
Park, Sun Young; Kim, Do Yeon; Kang, Jong-Koo; Park, Geuntae; Choi, Young-Whan
2014-09-01
Free radical-mediated neurodegeneration is one of the many causes of Parkinson's disease (PD). As part of our ongoing studies on the identification of biologically active Schisandra chinensis components, we have isolated and structurally elucidated α-iso-cubebenol. This study was carried out in an attempt to clarify the neuroprotective effect of α-iso-cubebenol on toxin-insulted dopaminergic neuronal death using 6-hydroxy-dopamine (6-OHDA)-induced dopaminergic SH-SY5Y cells. α-iso-cubebenol significantly attenuated the loss of mitochondrial function (MTT assay) and membrane integrity (lactate dehydrogenase assay) associated with 6-OHDA-induced neurotoxicity. Pretreatment of the cells with α-iso-cubebenol diminished the intracellular accumulation of reactive oxygen species (ROS) and calcium in response to 6-OHDA. Moreover, α-iso-cubebenol protected against 6-OHDA-induced neurotoxicity through inhibition of SH-SY5Y cell apoptosis. In addition, JC-1 staining, which is a well-established measure of mitochondrial damage, was decreased after treatment with α-iso-cubebenol. Notably, α-iso-cubebenol inhibited the release of mitochondrial flavoprotein apoptosis inducing factor (AIF) from the mitochondria to the cytosol and nucleus following 6-OHDA treatment. In addition, α-iso-cubebenol reduced the 6-OHDA-induced phosphorylation of ERK and induced the phosphorylation of PKA, PKB, and CREB in a dose-dependent manner. Moreover, α-iso-cubebenol stimulated the activation of Nrf2, a downstream target of CREB. Furthermore, α-iso-cubebenol stimulated the expression of multiple antioxidant response genes (NQO-1 and HO-1). Finally, CREB and Nrf2 siRNA transfection diminished α-iso-cubebenol-mediated neuroprotection. Copyright © 2014 Elsevier Inc. All rights reserved.
van 't Erve, Thomas J; Lih, Fred B; Kadiiska, Maria B; Deterding, Leesa J; Eling, Thomas E; Mason, Ronald P
2015-06-01
The biomarker 8-iso-prostaglandin F2α (8-iso-PGF2α) is regarded as the gold standard for detection of excessive chemical lipid peroxidation in humans. However, biosynthesis of 8-iso-PGF2α via enzymatic lipid peroxidation by prostaglandin-endoperoxide synthases (PGHSs), which are significantly induced in inflammation, could lead to incorrect biomarker interpretation. To resolve the ambiguity with this biomarker, the ratio of 8-iso-PGF2α to prostaglandin F2α (PGF2α) is established as a quantitative measure to distinguish enzymatic from chemical lipid peroxidation in vitro, in animal models, and in humans. Using this method, we find that chemical lipid peroxidation contributes only 3% to the total 8-iso-PGF2α in the plasma of rats. In contrast, the 8-iso-PGF2α levels in plasma of human males are generated >99% by chemical lipid peroxidation. This establishes the potential for an alternate pathway of biomarker synthesis, and draws into question the source of increases in 8-iso-PGF2α seen in many human diseases. In conclusion, increases in 8-iso-PGF2α do not necessarily reflect increases in oxidative stress; therefore, past studies using 8-iso-PGF2α as a marker of oxidative stress may have been misinterpreted. The 8-iso-PGF2α/PGF2α ratio can be used to distinguish biomarker synthesis pathways and thus confirm the potential change in oxidative stress in the myriad of disease and chemical exposures known to induce 8-iso-PGF2α. Published by Elsevier Inc.
The stability of iso-α-acids and reduced iso-α-acids in stored blood specimens.
Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H
2014-06-01
The long-term stability of the iso-α-acids, and three structurally similar but chemically altered iso-α-acids (known as 'reduced iso-α-acids' and consisting of the rho-, tetrahydro- and hexahydro-iso-α-acid groups) were investigated in whole blood. Pools of blank blood spiked with the four beer-specific ingredient congener groups at two different concentration levels were stored at 20°C, 4°C and -20°C; and extracted in duplicate in weeks 1, 3, 5 and 8, using a previously published method. A loss of 15% of the initial concentration was considered to indicate possible instability and losses greater than 30% demonstrated significant losses. The individual analytes within the four iso-α-acid groups were also measured to determine which iso-α-acids were subject to greater degradation and were responsible for the overall group instability. All four iso-α-acid groups showed significant losses after 8 weeks of storage under room temperature conditions in particularly the natural iso-α-acid group where major losses were observed (96% and 85% losses for low and high concentrations, respectively). Some degradation in all iso-α-acid groups were seen at 4°C samples predominantly due to the 'n' analogs of the groups showing an increased instability in blood. The -20°C storage conditions resulted in minimal changes in concentrations of all analytes. Higher than frozen storage temperatures can result in substantial changes on the stability of the iso-α-acid type groups in blood. The aim of this study was to highlight the stabilities of the IAA analytes in order to assist in the interpretation of IAA in stored blood specimens. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Strategic Technology Selection and Classification in Multimodel Environments
2008-05-01
processes. Specifically, the organization chose a blend of CMMI (portions of which were being implemented in engineering), ISO 12207 and the SA CMM...whole- product support Improve product field performance Strategy to accomplish goal Reference models CMMI, SA CMM, IEEE/ ISO 12207 Leverage CMMI...ro u p Lean Six Sigma SOX ISO /IEC 15288 ISO 9000 CMMI ISO 12207 P-CMM AS9100 IEEE 830 PSMIDEAL PPSLockheed Martin Integrated Enterprise Process Agile
Making the Business Case for Software Assurance
2009-04-01
and Capability dEtermination-SPICE, ISO /IEC 15504, 1998. [ ISO 2007] International Organization for Standardization. " ISO /IEC 27001 & 27002 ...Implementing the Process Areas 6.2.7 Differences Between the CMMI and Software CMM Process Areas 6.3 The CMMI Appraisal Process 6.4 Adapting ISO 15504 to...Secure Software Assurance 6.4.1 Assessment and the Secure Life Cycle 6.4.2 ISO 15504 Capability Levels 6.5 Adapting the ISOIIEC 21287 Standard Approach to
Researches on Preliminary Chemical Reactions in Spark-Ignition Engines
1943-06-01
correct ratio for air, mth’ was determined analyt- ically from the proportion of alcohols , olefines, 16 NACA Technical Memorandum No, 1049 ’\\ aromatics...umption is therefore permissible. The mix- ture ratio for a fuel will then depend on its aromatic and alcohol content as fdund by chemical analysis. The...composition, would behave differently. To obtain informa- tion on this point, tests wer~ made with pure iso-octane, ~thyl alcohol , and benzol, all
Environmentally Acceptable Lubricants
2011-11-30
CO2 >60% ASTM D-5864 Shake flask test CO2 >60% EPA 560/6-82-003 BODIS test BOD/COD >60% ISO 10708 Hydrocarbon degradability CEC test Infrared...several criteria proposed over the past few years to describe the point at which chemicals are no longer taken up in the body and bioaccumulated (Arnot...conducted by an approved third -party laboratory. The OSPAR protocols for methods for the testing of chemicals used in the offshore oil industry are
Specification and tolerancing of bulk glass material imperfections with ISO standards
NASA Astrophysics Data System (ADS)
Krisiloff, Allen J.
2017-08-01
Standards for the specification of tolerances for glass material imperfections have been evolving over the past 40 years. Today, several individual ISO Standards for drawings and drawing notation - ISO 10110-2, ISO-10110-3, and ISO- 10110-4, which were last revised in 1996 and 1997 - are being merged and re-written to incorporate technical improvements and enhance the clarity of presentation. The new standard, tentatively numbered ISO 10110-18, is on schedule for release in 2018. It will also provide notation to directly utilize concepts and quality classes defined in ISO 12123, the newly revised standard for raw glass material. New ways to specify striae and a way to specify raw material specifications on a finished part drawing are two additional highlights of the revised versions of this set of ISO standards. This paper will discuss the old shortcomings, their corrections, and the new features incorporated into the set of standards currently under final development and whose publication is expected next year.
Lamb, Joseph J; Holick, Michael F; Lerman, Robert H; Konda, Veera R; Minich, Deanna M; Desai, Anuradha; Chen, Tai C; Austin, Melissa; Kornberg, Jacob; Chang, Jyh-Lurn; Hsi, Alex; Bland, Jeffrey S; Tripp, Matthew L
2011-05-01
Metabolic syndrome poses additional risk for postmenopausal women who are already at risk for osteoporosis. We hypothesized that a nutritional supplement containing anti-inflammatory phytochemicals and essential bone nutrients would produce a favorable bone biomarker profile in postmenopausal women with metabolic syndrome. In this 14-week, randomized trial, 51 women were instructed to consume a modified Mediterranean-style, low-glycemic-load diet and to engage in aerobic exercise. Those in the intervention arm (n = 25) additionally received 200 mg hop rho iso-alpha acids, 100 mg berberine sulfate trihydrate, 500 IU vitamin D₃, and 500 μg vitamin K₁ twice daily. Forty-five women completed the study. Baseline nutrient intake did not differ between arms. Compared with baseline, the intervention arm exhibited an approximate 25% mean decrease (P < .001) in serum osteocalcin (indicative of bone turnover), whereas the placebo arm exhibited a 21% increase (P = .003). Serum 25-hydroxyvitamin D increased 23% (P = .001) in the intervention arm and decreased 12% (P = .03) in the placebo arm. The between-arm differences for osteocalcin and 25-hydroxyvitamin D were statistically significant. Serum insulin-like growth factor I was statistically increased in both arms, but the between-arm differences were not statistically significant. Subanalysis showed that among those in the highest tertile of baseline insulin-like growth factor I, the intervention arm exhibited a significant increase in amino-terminal propeptide of type I collagen, whereas the placebo arm showed a significant decrease at 14 weeks. Treatment with rho iso-alpha acids, berberine, vitamin D₃, and vitamin K₁ produced a more favorable bone biomarker profile indicative of healthy bone metabolism in postmenopausal women with metabolic syndrome. Copyright © 2011 Elsevier Inc. All rights reserved.
Schifter, Isaac; Díaz-Gutiérrez, Luis; Rodríguez-Lara, René; González-Macías, Carmen; González-Macías, Uriel
2017-05-01
Gasoline-ethanol-methanol fuel blends were formulated with the same stoichiometric air-to-fuel ratio and volumetric energy concentration as any binary ethanol-gasoline blend. When the stoichiometric blends operated in a vehicle, the time period, injector voltage, and pressure for each fuel injection event in the engine corresponded to a given stoichiometric air-to-fuel ratio, and the load was essentially constant. Three low oxygen content iso-stoichiometric ternary gasoline-ethanol-methanol fuel blends were prepared, and the properties were compared with regular-type fuel without added oxygen. One of the ternary fuels was tested using a fleet of in-use vehicles for15 weeks and compared to neat gasoline without oxygenated compounds as a reference. Only a small number of publications have compared these ternary fuels in the same engine, and little data exist on the performance and emissions of in-use spark-ignition engines. The total hydrocarbon emissions observed was similar in both fuels, in addition to the calculated ozone forming potential of the tailpipe and evaporative emissions. In ozone non-attainment areas, the original purpose for oxygenate gasolines was to decrease carbon monoxide emissions. The results suggest that the strategy is less effective than expected because there still exist a great number of vehicles that have suffered the progressive deterioration of emissions and do not react to oxygenation, while new vehicles are equipped with sophisticated air/fuel control systems, and oxygenation does not improve combustion because the systems adjust the stoichiometric point, making it insensitive to the origin of the added excess oxygen (fuel or excess air). Graphical abstract Low level ternary blend of gasoline-ethanol-methanol were prepared with the same stoichiometric air-fuel ratio and volumetric energy concentration, based on the volumetric energy density of the pre-blended components. Exhaust and evaporative emissions was compared with a blend having no oxygen in a fleet of 12 in-use vehicles. Vehicles that had suffer a normal deterioration of emissions and do not react to oxygenation, and new vehicles with more sophisticated air/fuel control systems do not improve combustion.
Assessment of Salmonella survival in dry-cured Italian salami.
Bonardi, S; Bruini, I; Bolzoni, L; Cozzolino, P; Pierantoni, M; Brindani, F; Bellotti, P; Renzi, M; Pongolini, S
2017-12-04
The inactivation of Salmonella during curing of Italian traditional pork salami was investigated. A total of 150 batches of ground raw meat (GRM) used for salami manufacturing by four producers were tested for Salmonella by real-time PCR followed by ISO 6579 cultural confirmation and MPN enumeration. Salami produced with Salmonella positive GRMs were re-tested at the end of their curing period. Aw, pH and NaCl content were also measured. Detection of Salmonella was performed testing both 25 and 50g of the samples. By Real-Time PCR 37% of the GRMs resulted positive, but cultural detection of Salmonella was obtained in 14% of the samples only. Salmonella enumeration ranged from 31 MPN/g to <1.3 MPN/g. The difference between testing 50g and 25g of the samples was statistically significant (p value≤0.01). In particular, ISO-50g detected Salmonella in 100% of all positive samples, vs. 62% of ISO-25g. Salami made of the contaminated GRMs were 29% Salmonella-positive, as most batches of salami produced with Salmonella-positive GRMs resulted negative after regular curing (20-48days). Overall, 13% of salami produced with Salmonella-contaminated GRMs were positive. They belonged to six batches, which turned out negative after prolonged curing ranging between 49 and 86days. Salmonella enumeration in salami ranged from 8.7 MPN/g to <1.3 MPN/g. Unlike GRMs, no significant difference was observed between the ISO-50g and the ISO-25g in detecting Salmonella in cured salami (p value: >0.05). The most common Salmonella serovars in GRMs were Derby (52%), Typhimurium monophasic variant 4, (Barbuti et al., 1993), 12:i:- (19%) and Stanley (10%). Salmonella Derby (56%), London, Branderup, Panama (13%, respectively) and Goldcoast (6%) were most frequent in cured salami. The study showed negative correlation between real-time CT values and cultural confirmation of Salmonella, as well as the importance of sample size for Salmonella detection. Among considered factors with possible effect on the occurrence of Salmonella in salami, statistical analysis revealed a role for aw in salami and for Salmonella load in GRMs, while pH and NaCl content did not significantly affect the probability of finding Salmonella in dry-cured salami in the context of this study. In particular the lower aw values due to longer curing were associated with lower Salmonella presence in traditional dry-cured salami. Copyright © 2017 Elsevier B.V. All rights reserved.
Van't Erve, Thomas J; Lih, Fred B; Jelsema, Casey; Deterding, Leesa J; Eling, Thomas E; Mason, Ronald P; Kadiiska, Maria B
2016-06-01
Oxidative stress is elevated in numerous environmental exposures and diseases. Millions of dollars have been spent to try to ameliorate this damaging process using anti-oxidant therapies. Currently, the best accepted biomarker of oxidative stress is the lipid oxidation product 8-iso-prostaglandin F2α (8-iso-PGF2α), which has been measured in over a thousand human and animal studies. 8-iso-PGF2α generation has been exclusively attributed to nonenzymatic chemical lipid peroxidation (CLP). However, 8-iso-PGF2α can also be produced enzymatically by prostaglandin-endoperoxide synthases (PGHS) in vivo. When failing to account for PGHS-dependent generation, 8-iso-PGF2α cannot be interpreted as a selective biomarker of oxidative stress. We investigated the formation of 8-iso-PGF2α in rats exposed to carbon tetrachloride (CCl4) or lipopolysaccharide (LPS) using the 8-iso-PGF2α/PGF2α ratio to quantitatively determine the source(s) of 8-iso-PGF2α. Upon exposure to a 120mg/kg dose of CCl4, the contribution of CLP accounted for only 55.6±19.4% of measured 8-iso-PGF2α, whereas in the 1200mg/kg dose, CLP was the predominant source of 8-iso-PGF2α (86.6±8.0% of total). In contrast to CCl4, exposure to 0.5mg/kg LPS was characterized by a significant increase in both the contribution of PGHS (59.5±7.0) and CLP (40.5±14.0%). In conclusion, significant generation of 8-iso-PGF2α occurs through enzymatic as well as chemical lipid peroxidation. The distribution of the contribution is dependent on the exposure agent as well as the dose. The 8-iso-PGF2α/PGF2α ratio accurately determines the source of 8-iso-PGF2α and provides an absolute measure of oxidative stress in vivo. Copyright © 2016. Published by Elsevier Inc.
Biodegradability Evaluation of Polymers by ISO 14855-2
Funabashi, Masahiro; Ninomiya, Fumi; Kunioka, Masao
2009-01-01
Biodegradabilities of polymers and their composites in a controlled compost were described. Polycaprolactone (PCL) and poly(lactic acid) (PLA) were employed as biodegradable polymers. Biodegradabilities of PCL and PLA samples in a controlled compost were measured using a Microbial Oxidative Degradation Analyzer (MODA) according to ISO 14855-2. Sample preparation method for biodegradation test according to ISO/DIS 10210 was also described. Effects of sizes and shapes of samples on biodegradability were studied. Reproducibility of biodegradation test of ISO 14855-2 by MODA was confirmed. Validity of sample preparation method for polymer pellets, polymer film, and polymer products of ISO/DIS 10210 for ISO 14855-2 was confirmed. PMID:20111676
Iso-α-acids, bitter components of beer, prevent obesity-induced cognitive decline.
Ayabe, Tatsuhiro; Ohya, Rena; Kondo, Keiji; Ano, Yasuhisa
2018-03-19
Dementia and cognitive decline have become worldwide public health problems, and it was recently reported that life-style related diseases and obesity are key risk factors in dementia. Iso-α-acids, hop-derived bitter components of beer, have been reported to have various physiological functions via activation of peroxisome proliferator-activated receptor γ. In this report, we demonstrated that daily intake of iso-α-acids suppresses inflammations in the hippocampus and improves cognitive decline induced by high fat diet (HFD). Body weight, epididymal fat weight, and plasma triglyceride levels were increased in HFD-fed mice, and significantly decreased in iso-α-acids supplemented HFD-fed mice. HFD feeding enhances the production of inflammatory cytokines and chemokines, such as TNF-α, which was significantly suppressed by iso-α-acids administration. HFD-induced neuroinflammation caused lipid peroxidation, neuronal loss, and atrophy in hippocampus, and those were not observed in iso-α-acids-treated mice. Furthermore, iso-α-acids intake significantly improved cognitive decline induced by HFD-feeding. Iso-α-acids are food derived components that suppressing both lipid accumulation and brain inflammation, thus iso-α-acids might be beneficial for the risk of dementia increased by obesity and lifestyle-related diseases.
NASA Astrophysics Data System (ADS)
Kaus, Rüdiger
This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.
76 FR 56192 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
...-000. Applicants: ISO New England Inc. Description: ISO New England Inc. Resource Termination Filing.... Eastern Time on Thursday, September 22, 2011. Docket Numbers: ER11-4420-000. Applicants: ISO New England Inc. Description: ISO New England Inc. Resource Termination Filing-- EnerNOC. Filed Date: 09/01/2011...
Variations in medial-lateral hamstring force and force ratio influence tibiofemoral kinematics.
Shalhoub, Sami; Fitzwater, Fallon G; Cyr, Adam J; Maletsky, Lorin P
2016-10-01
A change in hamstring strength and activation is typically seen after injuries or invasive surgeries such as anterior cruciate reconstruction or total knee replacement. While many studies have investigated the influence of isometric increases in hamstring load on knee joint kinematics, few have quantified the change in kinematics due to a variation in medial to lateral hamstring force ratio. This study examined the changes in knee joint kinematics on eight cadaveric knees during an open-chain deep knee bend for six different loading configurations: five loaded hamstring configurations that varied the ratio of a total load of 175 N between the semimembranosus and biceps femoris and one with no loads on the hamstring. The anterior-posterior translation of the medial and lateral femoral condyles' lowest points along proximal-distal axis of the tibia, the axial rotation of the tibia, and the quadriceps load were measured at each flexion angle. Unloading the hamstring shifted the medial and lateral lowest points posteriorly and increased tibial internal rotation. The influence of unloading hamstrings on quadriceps load was small in early flexion and increased with knee flexion. The loading configuration with the highest lateral hamstrings force resulted in the most posterior translation of the medial lowest point, most anterior translation of the lateral lowest point, and the highest tibial external rotation of the five loading configurations. As the medial hamstring force ratio increased, the medial lowest point shifted anteriorly, the lateral lowest point shifted posteriorly, and the tibia rotated more internally. The results of this study, demonstrate that variation in medial-lateral hamstrings force and force ratio influence tibiofemoral transverse kinematics and quadriceps loads required to extend the knee. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1707-1715, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zheng, Yuan-Bo; Ruan, Guo-Mo; Fu, Jia-Xing; Su, Zhong-Liang; Cheng, Peng; Lu, Jian-Zuo
2016-04-01
Oxidative stress may be involved in occurrence of postoperative delirium (POD) and cognitive dysfunction (POCD). 8-iso-Prostaglandin F2α (8-iso-PGF2α), an isoprostane derived from arachidonic acid via lipid peroxidation, is considered a gold standard for measuring oxidative stress. The present study aimed to investigate the ability of postoperative plasma 8-iso-PGF2α levels to predict POD and POCD in elderly patients undergoing hip fracture surgery. Postoperative plasma 8-iso-PGF2α levels of 182 patients were measured by an enzyme-linked immunosorbent assay. We assessed the relationships between plasma 8-iso-PGF2α levels and the risk of POD and POCD using a multivariate analysis. Plasma 8-iso-PGF2α levels and age were identified as the independent predictors for POD and POCD. Based on areas under receiver operating characteristic curve, the predictive values of 8-iso-PGF2α were obviously higher than those of age for POD and POCD. In a combined logistic-regression model, 8-iso-PGF2α significantly enhanced the areas under curve of age for prediction of POD and POCD. Postoperative plasma 8-iso-PGF2α levels may have the potential to predict POD and POCD in elder patients undergoing hip fracture surgery. Copyright © 2016 Elsevier B.V. All rights reserved.
Ioannou, Kyriaki; Cheng, Kai Fan; Crichlow, Gregg V; Birmpilis, Anastasios I; Lolis, Elias J; Tsitsilonis, Ourania E; Al-Abed, Yousef
2014-10-01
Macrophage migration inhibitory factor (MIF) is a pleiotropic pro-inflammatory cytokine, which possesses a contributing role in cancer progression and metastasis and, thus, is now considered a promising anticancer drug target. Many MIF-inactivating strategies have proven successful in delaying cancer growth. Here, we report on the synthesis of ISO-66, a novel, highly stable, small-molecule MIF inhibitor, an analog of ISO-1 with improved characteristics. The MIF:ISO-66 co-crystal structure demonstrated that ISO-66 ligates the tautomerase active site of MIF, which has previously been shown to play an important role in its biological functions. In vitro, ISO-66 enhanced specific and non-specific anticancer immune responses, whereas prolonged administration of ISO-66 in mice with established syngeneic melanoma or colon cancer was non-toxic and resulted in a significant decrease in tumor burden. Subsequent ex vivo analysis of mouse splenocytes revealed that the observed decrease in tumor growth rates was likely mediated by the selective in vivo expansion of antitumor-reactive effector cells induced by ISO-66. Compared to other MIF-inactivating strategies employed in vivo, the anticancer activity of ISO-66 is demonstrated to be of equal or better efficacy. Our findings suggest that targeting MIF, via highly specific and stable compounds, such as ISO-66, may be effective for cancer treatment and stimulation of anticancer immune responses.
Tang, Fen; Jiang, Zhentao; Tan, Wenting; Long, Junrong; Liu, Shengquan; Chu, Chun
2017-08-28
To observe the effects of Shexiang Baoxin Pill (SBP) on isoprenaline (Iso)-induced changes in myocardial cell volume, shape, and connexin 43 (Cx43) expression. Methods: H9C2 myocardial cells were randomly divided into a control group, a Iso group and a Iso+SBP group. After 72 h of culture, the average surface area of H9C2 cells was measured under phase contrast microscope. Bicinchoninic acid (BCA) protein assay was carried out to determine the concentration of proteins. The survival rate of myocardial cells was measured by methylthiazolyldiphenyl-tetrazolium bromide (MTT) assay, and the Cx43 expression was detected by Western blot. Results: The mean surface area and Cx43 concentration in Iso-treated myocardial cells were increased under the phase contrast microscope (P<0.05). Compared with the Iso group, the mean surface area was decreased, and the Cx43 concentration was reduced in the Iso+SBP group (both P<0.05). Compared with the control group, the Cx43 expression was obviously down-regulated in the H9C2 cells of the Iso group (P<0.05); while compared with the Iso group, the Cx43 expression was obviously up-regulated in the Iso+SBP group (P<0.05). Conclusion: Shexiang Baoxin Pills can prevent Iso-induced myocardial hypertrophy and down-regulate Cx43 expression.
The design of optimal electric power demand management contracts
NASA Astrophysics Data System (ADS)
Fahrioglu, Murat
1999-11-01
Our society derives a quantifiable benefit from electric power. In particular, forced outages or blackouts have enormous consequences on society, one of which is loss of economic surplus. Electric utilities try to provide reliable supply of electric power to their customers. Maximum customer benefit derives from minimum cost and sufficient supply availability. Customers willing to share in "availability risk" can derive further benefit by participating in controlled outage programs. Specifically, whenever utilities foresee dangerous loading patterns, there is a need for a rapid reduction in demand either system-wide or at specific locations. The utility needs to get relief in order to solve its problems quickly and efficiently. This relief can come from customers who agree to curtail their loads upon request in exchange for an incentive fee. This thesis shows how utilities can get efficient load relief while maximizing their economic benefit. This work also shows how estimated customer cost functions can be calibrated, using existing utility data, to help in designing efficient demand management contracts. In order to design such contracts, optimal mechanism design is adopted from "Game Theory" and applied to the interaction between a utility and its customers. The idea behind mechanism design is to design an incentive structure that encourages customers to sign up for the right contract and reveal their true value of power. If a utility has demand management contracts with customers at critical locations, most operational problems can be solved efficiently. This thesis illustrates how locational attributes of customers incorporated into demand management contract design can have a significant impact in solving system problems. This kind of demand management contracts can also be used by an Independent System Operator (ISO). During times of congestion a loss of economic surplus occurs. When the market is too slow or cannot help relieve congestion, demand management can help solve the problem. Another tool the ISO requires for security purposes is reserves. Even though demand management contracts may not be a good substitute for spinning reserves, they are adequate to augment or replace supplemental and backup reserves.
Blood and urine 8-iso-PGF2α levels in babies of different gestational ages.
Li, Sitao; Hao, Hu; Zhou, Ping; Gao, Ping Ming; Xiao, Xin
2014-01-01
We measured cord blood and urine 8-iso-prostaglandin F2α (8-iso-PGF2α) levels in babies of different gestational ages to determine lipid peroxidation status. Babies at gestational ages of 28-43 weeks were divided into group A (28-32 weeks), group B (33-36 weeks), group C (37-41 weeks), and group D (42-43 weeks). 8-iso-PGF2α in umbilical cord blood (UCB) at birth and urine at 6 hours after birth was and tested by ELISA. UCB and urine 8-iso-PGF2α levels in group C were 130.09 ± 31.73 pg/ml and 27.14 ± 6.73 pg/ml, respectively. UCB 8-iso-PGF2α levels in group A and B were 188.42 ± 59.34 pg/ml and 189.37 ± 68.46 pg/ml, and urine 8-iso-PGF2α were 32.14 ± 7.32 pg/ml and 30.46 ± 8.83 pg/ml, respectively. Blood and urine 8-iso-PGF2α levels in group D (post-term) were 252.01 ± 46.42 pg/ml and 44.00 ± 8.50 pg/ml. For all babies, UCB and urine iso-PGF2α levels were significantly correlated (r = 0.65, P < 0.01). We established blood and urine iso-PGF2α levels in normal full-term babies. Urine 8-iso-PGF2α levels may reflect the extent of lipid peroxidation in babies. In pre-term and post-term babies, there was evidence for increased lipid peroxidation.
Liang, Yuguang; Zhu, Junlan; Huang, Haishan; Xiang, Daimin; Li, Yang; Zhang, Dongyun; Li, Jingxia; Wang, Yulei; Jin, Honglei; Jiang, Guosong; Liu, Zeyuan; Huang, Chuanshu
2016-08-02
Isorhapontigenin (ISO) is a new derivative of stilbene isolated from the Chinese herb Gnetum cleistostachyum. Our recent studies have revealed that ISO treatment at doses ranging from 20 to 80 μM triggers apoptosis in multiple human cancer cell lines. In the present study, we evaluated the potential effect of ISO on autophagy induction. We found that ISO treatment at sublethal doses induced autophagy effectively in human bladder cancer cells, which contributed to the inhibition of anchorage-independent growth of cancer cells. In addition, our studies revealed that ISO-mediated autophagy induction occurred in a SESN2 (sestrin 2)-dependent and BECN1 (Beclin 1, autophagy related)-independent manner. Furthermore, we identified that ISO treatment induced SESN2 expression via a MAPK8/JNK1 (mitogen-activated protein kinase 8)/JUN-dependent mechanism, in which ISO triggered MAPK8-dependent JUN activation and facilitated the binding of JUN to a consensus AP-1 binding site in the SESN2 promoter region, thereby led to a significant transcriptional induction of SESN2. Importantly, we found that SESN2 expression was dramatically downregulated or even lost in human bladder cancer tissues as compared to their paired adjacent normal tissues. Collectively, our results demonstrate that ISO treatment induces autophagy and inhibits bladder cancer growth through MAPK8-JUN-dependent transcriptional induction of SESN2, which provides a novel mechanistic insight into understanding the inhibitory effect of ISO on bladder cancers and suggests that ISO might act as a promising preventive and/or therapeutic drug against human bladder cancer.
GT200 getting better than 34% efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farmer, R.
1980-01-01
Design features are described for the GT200, a 50-Hz machine blend of high temperature advanced aircraft rotating components and heavy frame industrial gas turbine structure. It includes a twin spool as generator with a two-stage power turbine giving nominal performance of 85,000 kW ISO peak output with a 10,120 Btu per kW-h heat rate on LHV distillate. It is desgined for base, intermediate, or peak load operation simple or combined cycle. Stal-Laval in Sweden developed it and sold the first unit to the Swedish State Power Board in July 1977. The unit was installed at the Stallbocka Station.
Finite element analysis of ROPS for mechanical driving dump truck cab
NASA Astrophysics Data System (ADS)
Wang, Yong; Xie, Heping; Fang, Yuanbin; Feng, Handui; Dong, Lei
2018-02-01
For roll-over protective structures (ROPS) in a mechanical driving dump truck cab, it simulates the lateral, vertical and longitudinal loads of ROPS. It obtains stress and deformation of the cab that occurs to roll. For the relative weak position of ROPS in the cab, the structure of the cab is improved and verified according to the ISO 3164: 1995. The results show that the established finite element model can effectively predict the deformation and stress distribution of ROPS, and optimize the weak structure of the cab, which has important guiding significance for structural design of the cab and ROPS optimization of the mechanical driving dump truck cab.
chain MS ISO/IEC 27001: 2007 Information Security Management Systems MS ISO 50001: 2011 Energy . Announcements Popular Standards Popular Standards MS ISO 9001 :2015 Quality Management System(QMS) MS ISO 14001 : 2015 Environmental Management Systems(EMS) MS 1722:2011 & OHSAS 18001:2007 Occupational Health and
76 FR 64343 - Notice of Commission Staff Attendance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... may attend the following meetings related to the transmission planning activities of ISO New England... meetings are open to stakeholders. Further information may be found at http://www.iso-ne.com . The... No. ER11-4021, ISO New England Inc., Northeast Utilities Service Company. Docket No. ER11-4022, ISO...
78 FR 53747 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
.... Applicants: ISO New England Inc. Description: ISO New England Inc. Resource Termination-- Constellation... Due: 5 p.m. e.t. 9/11/13. Docket Numbers: ER13-2212-000. Applicants: ISO New England Inc. Description: ISO New England Inc. Resource Termination--Waterbury Generation. Filed Date: 8/21/13. Accession Number...
Use of photostress to analyze behavior of an aft skirt test specimen
NASA Technical Reports Server (NTRS)
Gambrell, S. C., Jr.
1994-01-01
Strains at twenty-one selected points in the critical lower weld region of a aft skirt of a solid rocket booster of the shuttle were measured using photoelastic coatings and stress separator gages. Data were taken at loads of 5, 14, 20, 28, 42, 56, and 70 percent of the design limit load. Results indicate that general yielding occurred in the weld metal and for a short distance outside the fusion boundaries on either side of the weld metal. The fusion boundaries did not yield at the 70 percent load. Slight non-linearity in the load strain curves were observed at several points above the 20 percent load level. Maximum measured strains occurred at points in the forged metal of the holddown post along a line 0.50 inches from the centerline of the weld. Maximum shearing strains within the area covered by the photoelastic coating occurred at points approximately 0.33 inches to the right of the weld centerline near points 6 and 7 and lying along a yellow vertical line extending from just below point 6 to point 11. Photoelastic coatings were shown to be an excellent method to provide the whole field strain distribution in the region of the critical weld and to enhance the overall understanding of the behavior of the welded joint.
Pollution loads in urban runoff and sanitary wastewater.
Taebi, Amir; Droste, Ronald L
2004-07-05
While more attention has been paid in recent years to urban point source pollution control through the establishment of wastewater treatment plants in many developing countries, no considerable planning nor any serious measures have been taken to control urban non-point source pollution (urban stormwater runoff). The present study is a screening analysis to investigate the pollution loads in urban runoff compared to point source loads as a first prerequisite for planning and management of receiving water quality. To compare pollutant loads from point and non-point urban sources, the pollutant load is expressed as the weight of pollutant per hectare area per year (kg/ha.year). Unit loads were estimated in stormwater runoff, raw sanitary wastewater and secondary treatment effluents in Isfahan, Iran. Results indicate that the annual pollution load in urban runoff is lower than the annual pollution load in sanitary wastewater in areas with low precipitation but it is higher in areas with high precipitation. Two options, namely, advanced treatment (in lieu of secondary treatment) of sanitary wastewater and urban runoff quality control systems (such as detention ponds) were investigated as controlling systems for pollution discharges into receiving waters. The results revealed that for Isfahan, as a low precipitation urban area, advanced treatment is a more suitable option, but for high precipitation urban areas, urban surface runoff quality control installations were more effective for suspended solids and oxygen-demanding matter controls, and that advanced treatment is the more effective option for nutrient control.
Healy, Thomas W; Fuerstenau, Douglas W
2007-05-01
From our previous work on the role of the electrostatic field strength in controlling the pH of the iso-electric point (iep)/point-of-zero-charge (pzc) of polar solids we have extended the analysis to predict that the pH of the iep/pzc of a nonpolar solid, liquid or gas-aqueous interface should occur at pH 1.0-3.0, dependent on the value assigned to water molecules or clusters at the interface. Consideration of a wide range of experimental results covering nonpolar solids such as molybdenite, stibnite, paraffin, etc. as well as hydrocarbon liquids such as xylene, decalin, and long chain (>C8) alkane oils, as well as nitrogen and hydrogen gases, all in various simple 1:1 electrolyte solutions confirm the general validity of the result. We further consider various models of the origin of the charge on nonpolar material-water interfaces.
Understanding and Leveraging a Supplier’s CMMI Efforts: A Guidebook for Acquirers (Revised for V1.3)
2011-09-01
and SCAMPI (e.g., ISO /IEC 15288, 12207 , 15504; ISO 9001, EIA 632, and IEEE 1220), or if there are processes to be implemented that are not captured...process descriptions and tailoring as well as any formal audit results. ISO -9001:2008 is a quality management standard for development created and...maintained by the International Organisation for Standardisation ( ISO ). The American National Standard equivalent is ANSI/ ISO /ASQ Q9001-2008
Understanding and Leveraging a Supplier’s CMMI(Trademark) Efforts: A Guidebook for Acquirers
2007-03-01
other than CMMI and SCAMPI (e.g., ISO /IEC 15288, 12207 , 15504; ISO 9001, EIA 632, and IEEE 1220), or if there are processes to be implemented that are...tailoring as well as any formal audit results. 40 | CMU/SEI-2007-TR-004 ISO -9001:2000 is a quality management standard for development created and...maintained by the International Organisation for Standardisation ( ISO ). The American National Standard equivalent is ANSI/ ISO /ASQ Q9001-2000
International Organization for Standardization (ISO) 15189
Schneider, Frank; Friedberg, Richard C.
2017-01-01
The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. PMID:28643484
Another HISA--the new standard: health informatics--service architecture.
Klein, Gunnar O; Sottile, Pier Angelo; Endsleff, Frederik
2007-01-01
In addition to the meaning as Health Informatics Society of Australia, HISA is the acronym used for the new European Standard: Health Informatics - Service Architecture. This EN 12967 standard has been developed by CEN - the federation of 29 national standards bodies in Europe. This standard defines the essential elements of a Service Oriented Architecture and a methodology for localization particularly useful for large healthcare organizations. It is based on the Open Distributed Processing (ODP) framework from ISO 10746 and contains the following parts: Part 1: Enterprise viewpoint. Part 2: Information viewpoint. Part 3: Computational viewpoint. This standard is now also the starting point for the consideration for an International standard in ISO/TC 215. The basic principles with a set of health specific middleware services as a common platform for various applications for regional health information systems, or large integrated hospital information systems, are well established following a previous prestandard. Examples of large scale deployments in Sweden, Denmark and Italy are described.
Comparative Effects of Urocortins and Stresscopin on Cardiac Myocyte Contractility
Makarewich, Catherine A.; Troupes, Constantine D.; Schumacher, Sarah M.; Gross, Polina; Koch, Walter J.; Crandall, David L.; Houser, Steven R.
2015-01-01
Rationale There is a current need for development of new therapies for patients with heart failure. Objective To test the effects of members of the Corticotropin-Releasing Factor (CRF) family of peptides on myocyte contractility to validate them as potential heart failure therapeutics. Methods and Results Adult feline left ventricular myocytes (AFMs) were isolated and contractility was assessed in the presence and absence of CRF peptides Urocortin 2 (UCN2), Urocortin 3 (UCN3), Stresscopin (SCP), and the β-adrenergic agonist isoproterenol (Iso). An increase in fractional shortening and peak Ca2+ transient amplitude was seen in the presence of all CRF peptides. A decrease in Ca2+ decay rate (Tau) was also observed at all concentrations tested. cAMP generation was measured by ELISA in isolated AFMs in response to the CRF peptides and Iso and significant production was seen at all concentrations and time points tested. Conclusions The CRF family of peptides effectively increases cardiac contractility and should be evaluated as potential novel therapeutics for heart failure patients. PMID:26231084
Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène
2015-05-01
The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.
Isostatic gravity map of the Monterey 30 x 60 minute quadrangle and adjacent areas, California
Langenheim, V.E.; Stiles, S.R.; Jachens, R.C.
2002-01-01
The digital dataset consists of one file (monterey_100k.iso) containing 2,385 gravity stations. The file, monterey_100k.iso, contains the principal facts of the gravity stations, with one point coded per line. The format of the data is described below. Each gravity station has a station name, location (latitude and longitude, NAD27 projection), elevation, and an observed gravity reading. The data are on the IGSN71 datum and the reference ellipsoid is the Geodetic Reference System 1967 (GRS67). The free-air gravity anomalies were calculated using standard formulas (Telford and others, 1976). The Bouguer, curvature, and terrain corrections were applied to the free-air anomaly at each station to determine the complete Bouguer gravity anomalies at a reduction density of 2.67 g/cc. An isostatic correction was then applied to remove the long-wavelength effect of deep crustal and/or upper mantle masses that isostatically support regional topography.
Kinetics of Thermal Decomposition of Ammonium Perchlorate by TG/DSC-MS-FTIR
NASA Astrophysics Data System (ADS)
Zhu, Yan-Li; Huang, Hao; Ren, Hui; Jiao, Qing-Jie
2014-01-01
The method of thermogravimetry/differential scanning calorimetry-mass spectrometry-Fourier transform infrared (TG/DSC-MS-FTIR) simultaneous analysis has been used to study thermal decomposition of ammonium perchlorate (AP). The processing of nonisothermal data at various heating rates was performed using NETZSCH Thermokinetics. The MS-FTIR spectra showed that N2O and NO2 were the main gaseous products of the thermal decomposition of AP, and there was a competition between the formation reaction of N2O and that of NO2 during the process with an iso-concentration point of N2O and NO2. The dependence of the activation energy calculated by Friedman's iso-conversional method on the degree of conversion indicated that the AP decomposition process can be divided into three stages, which are autocatalytic, low-temperature diffusion and high-temperature, stable-phase reaction. The corresponding kinetic parameters were determined by multivariate nonlinear regression and the mechanism of the AP decomposition process was proposed.
Bolognese, Leonardo; Falsini, Giovanni; Schwenke, Carsten; Grotti, Simone; Limbruno, Ugo; Liistro, Francesco; Carrera, Arcangelo; Angioli, Paolo; Picchi, Andrea; Ducci, Kenneth; Pierli, Carlo
2012-01-01
Conflicting data have been reported on the effects of low-osmolar and iso-osmolar contrast media on contrast-induced acute kidney injury (CI-AKI). In particular, no clinical trial has yet focused on the effect of contemporary contrast media on CI-AKI, epicardial flow, and microcirculatory function in patients with ST-segment elevation acute myocardial infarction who undergo primary percutaneous coronary intervention. The Contrast Media and Nephrotoxicity Following Coronary Revascularization by Angioplasty for Acute Myocardial Infarction (CONTRAST-AMI) trial is a prospective, randomized, single-blind, parallel-group, noninferiority study aiming to evaluate the effects of the low-osmolar contrast medium iopromide compared to the iso-osmolar agent iodixanol on CI-AKI and tissue-level perfusion in patients with ST-segment elevation acute myocardial infarction. Four hundred seventy-five consecutive, unselected patients who underwent primary percutaneous coronary intervention were randomized to iopromide (n = 239) or iodixanol (n = 236). All patients received high-dose N-acetylcysteine and hydration. The primary end point was the proportion of patients with serum creatinine (sCr) increases ≥25% from baseline to 72 hours. Secondary end points were Thrombolysis In Myocardial Infarction (TIMI) myocardial perfusion grade, increase in sCr ≥50%, increase in sCr ≥0.5 or ≥1 mg/dl, and 1-month major adverse cardiac events. The primary end point occurred in 10% of the iopromide group and in 13% of the iodixanol group (95% confidence interval -9% to 3%, p for noninferiority = 0.0002). A TIMI myocardial perfusion grade of 0 or 1 was present in 14% of patients in the 2 groups. No differences between the 2 groups were found in any of the secondary analyses of sCr increase. No significant difference in 1-month major adverse cardiac events was found (8% vs 6%, p = 0.37). In conclusion, in a population of unselected patients with ST-segment elevation acute myocardial infarction who underwent primary percutaneous coronary intervention, iopromide was not inferior to iodixanol in the occurrence of CI-AKI; no significant differences were found in terms of tissue-level reperfusion and major adverse cardiac events between the 2 contrast agents. Copyright © 2012 Elsevier Inc. All rights reserved.
Some Phytomonas and Herpetomonas species form unique iso-branched polyunsaturated fatty acids.
Fish, W R; Holz, G G; Beach, D H
1982-01-01
Four trypanosomatid flagellates of the genera Phytomonas and Herpetomonas have been found to carry out the de novo biosynthesis of a variety of iso-branched, C18, C20 and C22, polyunsaturated fatty acids, with 2-5 methylene-interrupted double bonds, which have not been described heretofore from natural materials; iso-C18 delta 6,9, iso-C18 delta 9,12, iso-C20 delta 8,11,14, iso-C 20 delta 5,8,11,14, iso-C22 delta 4,7,10,13,16. Identifications were based upon combinations of chromatographic, chemical degradative, mass spectrometric and proton nuclear magnetic resonance spectrometric techniques. Under appropriate culture conditions, 85% of the total fatty acids of the organisms were branched. The subject trypanosomatids are recommended as model organisms with which to investigate influences of the physical properties of phospholipid fatty acyl groups on eukaryotic cell membrane functions.
First Results from the ISO-IRAS Faint Galaxy Survey
NASA Technical Reports Server (NTRS)
Wolstencroft, R. D.; Wehrle, A. E.; Levine, D. A.
1997-01-01
We present the first result from the ISO-IRAS Faint Galaxy Survey (IIFGS), a program designed to obtain ISO observations of the most distant and luminous galaxies in the IRAS Faint Source Survey by filling short gaps in the ISO observing schedule with pairs of 12um ISOCAM AND 90um ISOPHOT observation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-31
...-787-000] New England Power Generators Association Inc., Complainant v. ISO New England Inc., Respondent; ISO New England Inc. and New England Power Pool; Notice of Complaint March 24, 2010. Take notice... Inc. (Complainant) filed a formal complaint against ISO New England Inc. (Respondent) alleging that...
76 FR 41779 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
.... Applicants: ISO New England Inc., The Connecticut Light and Power Company. Description: ISO New England Inc. submits tariff filing per 35.13(a)(2)(i): Northeast Utilities Serv Co and ISO NE to be effective 8/30/2010..., July 29, 2011. Docket Numbers: ER11-4022-000. Applicants: ISO New England Inc., The Connecticut Light...
77 FR 11532 - Notice of Attendance at ISO New England and NEPOOL Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
... members of the Commission and Commission staff may attend upcoming ISO New England Inc. (ISO-NE) and New... Commission and Commission staff may attend the following meetings: \\1\\ Subcommittees, task forces, and..., the Commission and Commission staff may monitor the various meetings posted on the ISO-NE Web site...
[Osaka Medical Laboratory ISO15189 Study Group: History and Future Prospects of the Group].
Iguchi, Ken
2016-02-01
The IS015189 "Medical laboratories: Specific requirements regarding quality and competence" is an international standard issued by the International Organization for Standardization (ISO) in February 2003. In October 2004, pilot surveys were initiated in Japan prior to accreditation surveys scheduled to be started in 2005. In September 2005, the first ever ISO15189-accredited facility was established in Japan. With the background of limited information about and few opportunities to study ISO15189 in 2004, we established the Osaka Medical Laboratory ISO15189 Study Group as a unique association that anyone interested in the ISO is able to join. Approximately 900 people have participated in group meetings, which have been held a total of 11 times. Thus, our group has played a major role in ISO development in Japan. To date, approximately 100 facilities have been ISO15189-accredited in Japan, suggesting the need to take new steps regarding its accreditation. As our group has achieved our initial objective, we are planning to work towards taking new steps, such as interaction with accredited facilities.
Daud, Roshada; Maeda, Setsuo; Kameel, Nur Nazmin Mustafa; Ripin, Muhamad Yunus; Bakrun, Norazman; Md Zein, Raemy; Kido, Masaharu; Higuchi, Kiyotaka
2004-04-01
The purpose of this paper is to clarify the reference vibrotactile perception thresholds (VPT) for healthy people in Malaysia. The measurement equipment standard, ISO 13091-1, of the vibrotactile perception thresholds for the assessment of nerve dysfunction and the analysis and interpretation of measurements at the fingertips standard, ISO 13091-2, were published in ISO/TC108/SC4/WG8 on 2001 and 2003 individually. In the ISO 13091-2 standard, the reference VPT data were obtained from few research papers. Malaysian people's VPT data don't include to this standard. In Malaysia, when the VPT is using to diagnose of the hand-arm vibration syndrome, the reference VPT data need to compare with the worker's ones. But, Malaysia does not have the reference VPT data yet. So, in this paper, the VPT was measured by using ISO 13091-1 standard equipment to obtain the reference data for Malaysian people. And these data were compared with the ISO reference data on the ISO 13091-2 standard. From the comparison of these data, it was clear that the Malaysian healthy people's VPT data were consistent with the reference data of the ISO 13091-2 standard.
Hazelwood, Lucie A.; Walsh, Michael C.; Pronk, Jack T.; Daran, Jean-Marc
2010-01-01
The hop plant, Humulus lupulus L., has an exceptionally high content of secondary metabolites, the hop α-acids, which possess a range of beneficial properties, including antiseptic action. Studies performed on the mode of action of hop iso-α-acids have hitherto been restricted to lactic acid bacteria. The present study investigated molecular mechanisms of hop iso-α-acid resistance in the model eukaryote Saccharomyces cerevisiae. Growth inhibition occurred at concentrations of hop iso-α-acids that were an order of magnitude higher than those found with hop-tolerant prokaryotes. Chemostat-based transcriptome analysis and phenotype screening of the S. cerevisiae haploid gene deletion collection were used as complementary methods to screen for genes involved in hop iso-α-acid detoxification and tolerance. This screening and further analysis of deletion mutants confirmed that yeast tolerance to hop iso-α-acids involves three major processes, active proton pumping into the vacuole by the vacuolar-type ATPase to enable vacuolar sequestration of iso-α-acids and alteration of cell wall structure and, to a lesser extent, active export of iso-α-acids across the plasma membrane. Furthermore, iso-α-acids were shown to affect cellular metal homeostasis by acting as strong zinc and iron chelators. PMID:19915041
Soy isoflavone tablets reduce osteoporosis risk factors and obesity in middle-aged Japanese women.
Mori, Mari; Aizawa, Toru; Tokoro, Minoru; Miki, Tomohiro; Yamori, Yukio
2004-12-01
1. This study examines whether the supplementation of isoflavones (ISO) exerts beneficial effects on the bone mineral density (BMD) measured by dual energy X-ray absorptiometry (DEXA). 2. Eighty-one healthy Japanese pre- and postmenopausal women were randomly assigned to the following two groups taking either ISO (100 mg) tablets (ISO group) or placebo tablets (P group) containing vitamins C (25 mg) and E (5 mg) daily for 24 weeks in a double-blind placebo controlled parallel design. 3. Seventy women completed the intervention study (34 on ISO, 36 on P), only ISO group was proven to increase significantly BMD (P < 0.05 vs before) and to significantly decrease body fat measured by the DEXA (P < 0.0001 vs before and P < 0.05 vs P group), while BMI was maintained in ISO group despite significant BMI increase in P group. Thus, percent changes in BMI were significantly different between ISO and P groups (P < 0.05) 24 weeks after the intervention. 4. This prospective DEXA study confirmed a long-term ISO supplementation, 100 mg/day could not only prevent menopausal bone resorption but also increase BMD and decrease body fat concomitantly with BMI reduction. Enough ISO supplementation may contribute to the risk reduction of osteoporosis and obesity and, thus to overall health promotion in menopausal women.
NASA Astrophysics Data System (ADS)
Kefayati, Mahdi; Baldick, Ross
2015-07-01
Flexible loads, i.e. the loads whose power trajectory is not bound to a specific one, constitute a sizable portion of current and future electric demand. This flexibility can be used to improve the performance of the grid, should the right incentives be in place. In this paper, we consider the optimal decision making problem faced by a flexible load, demanding a certain amount of energy over its availability period, subject to rate constraints. The load is also capable of providing ancillary services (AS) by decreasing or increasing its consumption in response to signals from the independent system operator (ISO). Under arbitrarily distributed and correlated Markovian energy and AS prices, we obtain the optimal policy for minimising expected total cost, which includes cost of energy and benefits from AS provision, assuming no capacity reservation requirement for AS provision. We also prove that the optimal policy has a multi-threshold form and can be computed, stored and operated efficiently. We further study the effectiveness of our proposed optimal policy and its impact on the grid. We show that, while optimal simultaneous consumption and AS provision under real-time stochastic prices are achievable with acceptable computational burden, the impact of adopting such real-time pricing schemes on the network might not be as good as suggested by the majority of the existing literature. In fact, we show that such price responsive loads are likely to induce peak-to-average ratios much more than what is observed in the current distribution networks and adversely affect the grid.
Gao, Guangxun; Chen, Liang; Li, Jingxia; Zhang, Dongyun; Fang, Yong; Huang, Haishan; Chen, Xiequn; Huang, Chuanshu
2014-05-15
The cancer chemopreventive property of Chinese herb new isolate isorhapontigenin (ISO) and mechanisms underlying its activity have never been explored. Here we demonstrated that ISO treatment with various concentrations for 3 weeks could dramatically inhibit TPA/EGF-induced cell transformation of Cl41 cells in Soft Agar assay, whereas co-incubation of cells with ISO at the same concentrations could elicit G0/G1 cell-cycle arrest without redundant cytotoxic effects on non-transformed cells. Further studies showed that ISO treatment resulted in cyclin D1 downregulation in dose- and time-dependent manner. Our results indicated that ISO regulated cyclin D1 at transcription level via targeting JNK/C-Jun/AP-1 activation. Moreover, we found that ISO-inhibited JNK/C-Jun/AP-1 activation was mediated by both upregulation of MKP-1 expression through increasing its mRNA stability and deactivating MKK7. Most importantly, MKP-1 knockdown could attenuate ISO-mediated suppression of JNK/C-Jun activation and cyclin D1 expression, as well as G0/G1 cell cycle arrest and cell transformation inhibition, while ectopic expression of FLAG-cyclin D1 T286A mutant also reversed ISO-induced G0/G1 cell-cycle arrest and inhibition of cell transformation. Our results demonstrated that ISO is a promising chemopreventive agent via upregulating mkp-1 mRNA stability, which is distinct from its cancer therapeutic effect with downregulation of XIAP and cyclin D1 expression.
Tousen, Yuko; Matsumoto, Yu; Matsumoto, Chiho; Nishide, Yoriko; Nagahata, Yuya; Kobayashi, Isao; Ishimi, Yoshiko
2016-07-01
Equol is a metabolite of the soya isoflavone (ISO) daidzein that is produced by intestinal microbiota. Equol has greater oestrogenic activity compared with other ISO, and it prevents bone loss in postmenopausal women. Resistant starch (RS), which has a prebiotic activity and is a dietary fibre, was reported to promote equol production. Conversely, the intestinal microbiota is reported to directly regulate bone health by reducing inflammatory cytokine levels and T-lymphocytes in bone. The present study evaluated the combined effects of diet supplemented with ISO and RS on intestinal microbiota, equol production, bone mineral density (BMD) and inflammatory gene expression in the bone marrow of ovariectomised (OVX) mice. Female ddY strain mice, aged 8 weeks, were either sham-operated (Sham, n 7) or OVX. OVX mice were randomly divided into the following four groups (seven per group): OVX control (OVX); OVX fed 0·05 % ISO diet (OVX+ISO); OVX fed 9 % RS diet (OVX+RS); and OVX fed 0·05 % ISO- and 9 % RS diet (OVX+ISO+RS). After 6 weeks, treatment with the combination of ISO and RS increased equol production, prevented the OVX-induced decline in trabecular BMD in the distal femur by modulating the enteric environment and altered OVX-induced inflammation-related gene expression in the bone marrow. However, there were no significant differences in bone parameters between the ISO+RS and ISO-alone groups in OVX mice. Our findings suggest that the combination of ISO and RS might alter intestinal microbiota and immune status in the bone marrow, resulting in attenuated bone resorption in OVX mice.
Improving Earth Science Metadata: Modernizing ncISO
NASA Astrophysics Data System (ADS)
O'Brien, K.; Schweitzer, R.; Neufeld, D.; Burger, E. F.; Signell, R. P.; Arms, S. C.; Wilcox, K.
2016-12-01
ncISO is a package of tools developed at NOAA's National Center for Environmental Information (NCEI) that facilitates the generation of ISO 19115-2 metadata from NetCDF data sources. The tool currently exists in two iterations: a command line utility and a web-accessible service within the THREDDS Data Server (TDS). Several projects, including NOAA's Unified Access Framework (UAF), depend upon ncISO to generate the ISO-compliant metadata from their data holdings and use the resulting information to populate discovery tools such as NCEI's ESRI Geoportal and NOAA's data.noaa.gov CKAN system. In addition to generating ISO 19115-2 metadata, the tool calculates a rubric score based on how well the dataset follows the Attribute Conventions for Dataset Discovery (ACDD). The result of this rubric calculation, along with information about what has been included and what is missing is displayed in an HTML document generated by the ncISO software package. Recently ncISO has fallen behind in terms of supporting updates to conventions such updates to the ACDD. With the blessing of the original programmer, NOAA's UAF has been working to modernize the ncISO software base. In addition to upgrading ncISO to utilize version1.3 of the ACDD, we have been working with partners at Unidata and IOOS to unify the tool's code base. In essence, we are merging the command line capabilities into the same software that will now be used by the TDS service, allowing easier updates when conventions such as ACDD are updated in the future. In this presentation, we will discuss the work the UAF project has done to support updated conventions within ncISO, as well as describe how the updated tool is helping to improve metadata throughout the earth and ocean sciences.
NASA Astrophysics Data System (ADS)
Cowart, Jewel S.
Compliance to requirements of ISO is an important leadership problem for the International Aerospace Quality Group (IAQG) and the Aviation, Space and Defense (AS&D) companies. Furthermore, the IAQG seeks to understand the valuation of ISO/AS9100 requirements (2009), audit practices, management functions, business performance, customer satisfaction, and potential future concepts for the standard to assure quality. Since the release of the AS9100C total certification growth surpassed 1,100,000 organizations in 2010 with ISO 9001 series adoption and implementation governing business operations (ASQ, 2012b; ISO, 2011; Bernardo, Llach, & Marimon, 2011). Historians such as Crosby, Juran, Deming, and others established the foundation for quality assurance. Several researchers explored the issues which complicate overall benefits of ISO certification (Iwaro & Mwasha, 2012; Karthi et al., 2012; Sampaio et al., 2009). This study examined the effects on AS&D industries from ISO compliance to identify the implications (of ever-changing requirements) through an online survey of 15,000 practitioners. The research illuminated how ISO affects AS&D industries with current and future requirements for certification. The data showed that 75% of survey respondents report implementation of the AS9100C requirements still has benefits that outweigh the cost. Findings suggest that AS&D industries perceive significant value in the AS9100C document as part of the overall ISO 9000 series. In general, the comments from the survey can provide insight into the affects of ISO certification. The study concludes by recommending continued research to learn of further impacts from ISO certification within AS&D industries to improve the AS9100 document requirements for quality management systems.
Park, Sun Young; Jung, Won Jung; Kang, Jum Soon; Kim, Cheol-Min; Park, Geuntae; Choi, Young-Whan
2015-02-01
Since oxidative stress is critically involved in excitotoxic damage, we sought to determine whether the activation of the transcription factors, cAMP-responsive element binding protein (CREB) and nuclear factor (erythroid-derived 2)-like 2 (Nrf2, also known as NFE2L2), by α-iso-cubebene is involved in its protective effects against glutamate-induced neuronal cell death. Pre-treatment with α-iso-cubebene significantly attenuated glutamate-induced cytotoxicity in mouse hippocampus-derived neuronal cells. α-iso-cubebene also reduced the glutamate-induced generation of reactive oxygen species and calcium influx, thus preventing apoptotic cell death. α-iso-cubebene inhibited glutamate-induced mitochondrial membrane depolarization and, consequently, inhibited the release of the apoptosis-inducing factor from the mitochondria. Immunoblot anlaysis revealed that the phosphorylation of extracellular signal-regulated kinase (ERK) by glutamate was reduced in the presence of α-iso-cubebene. α-iso-cubebene activated protein kinase A (PKA), CREB and Nrf2, which mediate the expression of the antioxidant enzymes, heme oxygenase-1 (HO-1) and NAD(P)H dehydrogenase [quinone] 1 (NQO1), involved in neuroprotection. In addition, α-iso-cubebene induced the expression of antioxidant responsive element and CRE transcriptional activity, thus conferring neuroprotection against glutamate-induced oxidative injury. α-iso-cubebene also induced the expression of Nrf2-dependent genes encoding HO-1 and NQO1. Furthermore, the knockdown of CREB and Nrf2 by small interfering RNA attenuated the neuroprotective effects of α-iso-cubebene. Taken together, our results indicate that α-iso-cubebene protects HT22 cells from glutamate-induced oxidative damage through the activation of Nrf2/HO-1/NQO-1, as well as through the PKA and CREB signaling pathways.
Vernunft, A; Viergutz, T; Plinski, C; Weitzel, J M
2014-08-01
F2-isoprostanes such as 8-iso-prostaglandin F2
Zhang, Weichen; Li, Feibo; Ye, Yufu; Liu, Yuanxing; Yu, Songfeng; Cen, Chao; Chen, Xuliang; Zhou, Lin; Tang, Xiaofeng; Yu, Jun; Zheng, Shusen
2017-12-01
Ischemia-reperfusion injury after liver transplantation (LT) impairs graft function and affects prognosis of recipients. Isoglycyrrhizinate magnesium (Iso) is a hepatoprotective drug usually used after liver injury. In this study, we intended to explore whether Iso alone have protective effect after ischemia-reperfusion injury in a rat model of liver transplantation. We also aimed to study whether Iso could enhance the hepatoprotective effect of FK506 (tacrolimus) and underlying mechanism. Rats after LT were treated with different concentration of FK506 with or without, Iso or lower-dose FK506 plus Iso. Alanine transaminase, aspartate transaminase, and albumin level were measured after 48 hours, 72 hours, and 7 days. A cell ischemic/reperfusion model was established to further study the mechanism of hepatoprotective effect of FK506 and Iso. Iso treatment alone had no effect on liver grafts after LT, but lower-dose FK506 + Iso was better for maintenance of liver function than lower-dose FK506 alone at 48 hours, 72 hours, and 7 days after LT. In terms of mechanism, FK506 induced autophagy which resulted in significantly reduced apoptosis and maintained proliferative potential. However, autophagy induced by FK506 also lead to high-mobility group box (HMGB) 1 release from nuclei, resulting in hepatocyte injury through triggering of p38 phosphorylation and chemokine release. Iso effectively inhibited the release of HMGB1 and downstream inflammatory cytokines. Iso could inhibit release of HMGB1 by FK506 and enhance the hepatoprotective effect of FK506 in rat LT. Combining Iso with FK506 would be promising for the patients after LT.
Khorrami, A; Garjani, A; Ghanbarzadeh, S; Andalib, S
2014-04-01
Myocardial infarction (MI) was induced by subcutaneous injection of isoproterenol (ISO) to investigate the effect of ISO on Coenzyme Q10 (CoQ10) content of myocardium and subsequent effects on lipid peroxidation, electrocardiogram pattern and hemodynamic parameters of the rat's heart.36 male Wistar rats were divided randomly into 6 groups. To induce heart failure (HF) and MI, 10 and 100 mg/kg of ISO was administered subcutaneously for 10 and 2 consecutive days, respectively. The effects of ISO on myocardium CoQ10 content, concentration of malondialdehyde, ECG pattern and hemodynamic parameters of heart were analyzed.ISO-treated rats showed significant alteration in heart hemodynamic parameters such as reduction of left-ventricular systolic pressure, maximum and minimum rate of developed left ventricular pressure, besides increase of left ventricular end-diastolic pressure. Significant depletion of heart CoQ10 content (from 4.57 and 4.55 µg/100 mg tissue in control groups to 2.85 and 2.89 µg/100 mg tissue in ISO-induced HF and MI groups respectively) and increase in tissue levels of malondialdehyde (47.1 and 53.8 nmol/100 mg tissue in ISO-induced HF and MI groups, respectively) were also observed in ISO-treated animals compared with the normal animals (17.4 and 18.8 nmol/100 mg tissue in control groups, respectively). Additionally CoQ10 improved ISO effects on hemodynamic parameters and ECG pattern in ISO-induced HF and myocardial injury.The present findings have demonstrated that the cardiotoxic effects of ISO such as oxidative damage and hemodynamic declination might be related to depletion of CoQ10 concentration. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Zhang, Jiyan; Wang, Liru; Ma, Zhenya
2006-11-01
A focimeter is one of the basic ophthalmic instruments used in every optometric practice, and verification of the accuracy and calibration of the instrument are of the utmost importance. For many years the International Standardization for Organization requires that calibrations for all kinds of focimeters shall be accomplished by using test lenses described in ISO 9342:1996. These test lenses must be of high quality and of nominal back vertex power that is known with high accuracy. With the development of science and technology, ISO 9342 was revised in 2005. A new part ISO 9342-2 had been drafted for test lenses used to calibrate focimeters with contact lens measurement, and the original ISO 9342 was turned into the current ISO 9342-1, which could only be used to calibrate fociemters with spectacle lens measurement. As one of the standard drafters, the background for the newly published ISO 9342-2 is introduced in this study, and comparison between test lenses of ISO 9342-1 and ISO 9342-2 is made. Further, the influence of tolerance and uncertainty in design and production of standard test lenses of ISO 9342-2 is analyzed. The paraxial approximation is used to relate the lens parameters with back vertex power and to calculate the uncertainty budget. Moreover, one set of test lenses conforming to ISO 9342-2 is manufactured and experiments are done with it. Results show that test lenses described in ISO 9342-2 can correct the measurement errors of focimeters used for measuring contact lenses well, especially for spherical aberration, and the correction is more effective for spherical contact lenses with high back vertex power.
Zhang, Zhenxiong; Zhuang, Jianguo; Zhang, Cancan; Xu, Fadi
2013-04-01
Inhalation of isoflurane (ISO), a widely used volatile anesthetic, can produce clinical tachypnea. In dogs, this response is reportedly mediated by bronchopulmonary C-fibers (PCFs), but the relevant mechanisms remain unclear. Activation of transient A-type potassium current (IA) channels and delayed rectifier potassium current (IK) channels hyperpolarizes neurons, and inhibition of both channels by ISO increases neural firing. Due to the presence of these channels in the cell bodies of rat PCFs, we determined whether ISO could stimulate PCFs to produce tachypnea in anesthetized rats, and, if so, whether this response resulted from ISO-induced depolarization of the pulmonary C neurons via the inhibition of IA and IK. We recorded ventilatory responses to 5% ISO exposure in anesthetized rats before and after blocking PCF conduction and the responses of pulmonary C neurons (extracellularly recorded) to ISO exposure. ISO-induced (1mM) changes in pulmonary C neuron membrane potential and IA/IK were tested using the perforated patch clamp technique. We found that: (1) ISO inhalation evoked a brief tachypnea (∼7s) and that this response disappeared after blocking PCF conduction; (2) the ISO significantly elevated (by 138%) the firing rate of most pulmonary C neurons (17 out of 21) in the nodose ganglion; and (3) ISO perfusion depolarized the pulmonary C neurons in the vitro and inhibited both IA and IK, and this evoked-depolarization was largely diminished after blocking both IA and IK. Our results suggest that ISO is able to stimulate PCFs to elicit tachypnea in rats, at least partly, via inhibiting IA and IK, thereby depolarizing the pulmonary C neurons. Copyright © 2013. Published by Elsevier B.V.
Jiang, Guosong; Huang, Chao; Li, Jingxia; Huang, Haishan; Wang, Jingjing; Li, Yawei; Xie, Fei; Jin, Honglei; Zhu, Junlan; Huang, Chuanshu
2018-03-08
There are few approved drugs available for the treatment of muscle-invasive bladder cancer (MIBC). Recently, we have demonstrated that isorhapontigenin (ISO), a new derivative isolated from the Chinese herb Gnetum cleistostachyum, effectively induces cell-cycle arrest at the G0/G1 phase and inhibits anchorage-independent cell growth through the miR-137/Sp1/cyclin D1 axis in human MIBC cells. Herein, we found that treatment of bladder cancer (BC) cells with ISO resulted in a significant upregulation of p27, which was also observed in ISO-treated mouse BCs that were induced by N-butyl-N-(4-hydroxybutyl) nitrosamine (BBN). Importantly, knockdown of p27 caused a decline in the ISO-induced G0-G1 growth arrest and reversed ISO suppression of anchorage-independent growth in BC cells. Mechanistic studies revealed that ISO promoted p27 expression at mRNA transcription level through increasing direct binding of forkhead box class O1 (FOXO1) to its promoter, while knockdown of FOXO1 attenuated ISO inhibition of BC cell growth. On the other hand, ISO upregulated the 3'-untranslated region (3'-UTR) activity of p27, which was accompanied by a reduction of miR-182 expression. In line with these observations, ectopic expression of miR-182 significantly blocked p27 3'-UTR activity, whereas mutation of the miR-182-binding site at p27 mRNA 3'-UTR effectively reversed this inhibition. Accordingly, ectopic expression of miR-182 also attenuated ISO upregulation of p27 expression and impaired ISO inhibition of BC cell growth. Our results not only provide novel insight into understanding of the underlying mechanism related to regulation of MIBC cell growth but also identify new roles and mechanisms underlying ISO inhibition of BC cell growth.
Twenty new ISO standards on dosimetry for radiation processing
NASA Astrophysics Data System (ADS)
Farrar, H., IV
2000-03-01
Twenty standards on essentially all aspects of dosimetry for radiation processing were published as new ISO standards in December 1998. The standards are based on 20 standard practices and guides developed over the past 14 years by Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). The transformation to ISO standards using the 'fast track' process under ISO Technical Committee 85 (ISO/TC85) commenced in 1995 and resulted in some overlap of technical information between three of the new standards and the existing ISO Standard 11137 Sterilization of health care products — Requirements for validation and routine control — Radiation sterilization. Although the technical information in these four standards was consistent, compromise wording in the scopes of the three new ISO standards to establish precedence for use were adopted. Two of the new ISO standards are specifically for food irradiation applications, but the majority apply to all forms of gamma, X-ray, and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruit, vegetables, meats, spices, processed foods, plastics, inks, medical wastes, and paper. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties using the new ISO Type A and Type B evaluations. Unfortunately, nine of the 20 standards just adopted by the ISO are not the most recent versions of these standards and are therefore already out of date. To help solve this problem, efforts are being made to develop procedures to coordinate the ASTM and ISO development and revision processes for these and future ASTM-originating dosimetry standards. In the meantime, an additional four dosimetry standards have recently been published by the ASTM but have not yet been submitted to the ISO, and six more dosimetry standards are under development.
ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Jingjing; Rao, Prakash; Therkelsen, Peter
ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMSmore » while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.« less
Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data
NASA Technical Reports Server (NTRS)
Ulbrich, N.
2017-01-01
Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.
NASA Astrophysics Data System (ADS)
Shubina Helbert, Varvara; Dhondt, Matthieu; Homette, Remi; Arbab Chirani, Shabnam; Calloch, Sylvain
2018-03-01
Providing high hardness, low friction coefficient, as well as, relatively good corrosion resistance, chromium-plated coatings (∼20 μm) are widely used for steel cylinder rods in marine environment. However, the standardized corrosion test method (ISO 9227, NSS) used to evaluate efficiency of this type of coatings does not take into account in-service mechanical loadings on cylinder rods. Nevertheless, the uniform initial network of microcracks in chromium coating is changing under mechanical loadings. Propagation of these microcracks explains premature corrosion of the steel substrate. The aim of the study was to evaluate relationship between mechanical loadings, propagation of microcracks network and corrosion resistance of chromium coatings. After monotonic pre-loading tests, it was demonstrated by microscopic observations that the microcracks propagation started at stress levels higher than the substrate yield stress (520 MPa). The microcracks become effective, i.e. they have instantly undergone through the whole coating thickness to reach the steel substrate. The density of effective microcracks increases with the total macroscopic level, i.e. the intercrack distance goes from 60 ± 5 μm at 1% of total strain to approximately 27 ± 2 μm at 10%. Electrochemical measurements have shown that the higher the plastic strain level applied during mechanical loading, the more the corrosion potential of the sample decreased until reaching the steel substrate value of approximately ‑0.65 V/SCE after 2 h of immersion. The polarization curves have also highligthed an increase in the corrosion current density with the strain level. Therefore, electrochemical measurements could be used to realize quick and comprehensive assesment of the effect of monotonic pre-loadings on corrosion properties of the chromium coating.
Lin, Chun-Li; Kuo, Wen-Chuan; Chang, Yen-Hsiang; Yu, Jin-Jie; Lin, Yun-Chu
2014-08-01
This study investigates monitored micro-crack growth and damage in the ceramic/enamel adhesive interface using the acoustic emission (AE) technique with optical coherence tomography (OCT) under fatigue shear testing. Shear bond strength (SBS) was measured first with eight prepared ceramic/enamel adhesive specimens under static loads. The fatigue shear testing was performed with three specimens at each cyclic load according to a modified ISO14801 method, applying at 80%, 75%, 70%, and 65% of the SBS to monitor interface debonding. The number of cycles at each load was recorded until ceramic/enamel adhesive interface debonding occurred. The AE technique was used to detect micro-crack signals in static and fatigue shear bond tests. The results showed that the average SBS value in the static tests was 18.07 ± 1.72 MPa (mean ± standard deviation), expressed in Newton's at 56.77 ± 5.40N. The average number of fatigue cycles in which ceramic/enamel interface damage was detected in 80%, 75%, 70% and 65% of the SBS were 41, 410, 8141 and 76,541, respectively. The acoustic behavior varied according to the applied load level. Events were emitted during 65% and 70% fatigue tests. A good correlation was observed between the crack location in OCT images and the number of AE signal hits. The AE technique combined with OCT images as a pre-clinical assessment tool to determine the integrity of cemented load bearing restored ceramic material. Sustainable cyclic load stresses in ceramic/enamel bonded specimens were substantially lower than the measured SBS. Predicted S-N curve showed that the maximum endured load was 10.98 MPa (about 34.48 N) passing 10(6) fatigue cyclic. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Datacube Interoperability, Encoding Independence, and Analytics
NASA Astrophysics Data System (ADS)
Baumann, Peter; Hirschorn, Eric; Maso, Joan
2017-04-01
Datacubes are commonly accepted as an enabling paradigm which provides a handy abstraction for accessing and analyzing the zillions of image files delivered by the manifold satellite instruments and climate simulations, among others. Additionally, datacubes are the classic model for statistical and OLAP datacubes, so a further information category can be integrated. From a standards perspective, spatio-temporal datacubes naturally are included in the concept of coverages which encompass regular and irregular grids, point clouds, and general meshes - or, more abstractly, digital representations of spatio-temporally varying phenomena. ISO 19123, which is identical to OGC Abstract Topic 6, gives a high-level abstract definition which is complemented by the OGC Coverage Implementation Schema (CIS) which is an interoperable, yet format independent concretization of the abstract model. Currently, ISO is working on adopting OGC CIS as ISO 19123-2; the existing ISO 19123 standard is under revision by one of the abstract authors and will become ISO 19123-1. The roadmap agreed by ISO further foresees adoption of the OGC Web Coverage Service (WCS) as an ISO standard so that a complete data and service model will exist. In 2016, INSPIRE has adopted WCS as Coverage Download Service, including the datacube analytics language Web Coverage Processing Service (WCPS). The rasdaman technology (www.rasdaman.org) is both OGC and INSPIRE Reference Implementation. In the global EarthServer initiative rasdaman database sizes are exceeding 250 TB today, heading for the Petabyte frontier well in 2017. Technically, CIS defines a compact, efficient model for representing multi-dimensional datacubes in several ways. The classical coverage cube defines a domain set (where are values?), a range set (what are these values?), and range type (what do the values mean?), as well as a "bag" for arbitrary metadata. With CIS 1.1, coordinate/value pair sequences have been added, as well as tiled representations. Further, CIS 1.1 offers a unified model for any kind of regular and irregular grids, also allowing sensor models as per SensorML. Encodings include ASCII formats like GML, JSON, RDF as well as binary formats like GeoTIFF, NetCDF, JPEG2000, and GRIB2; further, a container concept allows mixed representations within one coverage file utilizing zip or other convenient package formats. Through the tight integration with the Sensor Web Enablement (SWE), a lossless "transport" from sensor into coverage world is ensured. The corresponding service model of WCS supports datacube operations ranging from simple data extraction to complex ad-hoc analytics with WPCS. Notably, W3C is working has set out on a coverage model as well; it has been designed relatively independently from the abovementioned standards, but there is informal agreement to link it into the CIS universe (which allows for different, yet interchangeable representations). Particularly interesting in the W3C proposal is the detailed semantic modeling of metadata; as CIS 1.1 supports RDF, a tight coupling seems feasible.
A Manual for the Performance of Protective Equipment Fit-Mapping
2009-10-01
is not right, the grain would be neither perpendicular nor parallel to the floor. This causes unnecessary wrinkles and asymmetry of the right and...Prominent, anterior point on the anterior rim of the ilia. Note: The ilia are one of the three pair of bones that comprise the bony pelvis . 71...the three pair of bones that comprise the bony pelvis . Landmark Name: Iliocristale, Left and Right ISO Definition No. N/A CAESAR Name
Approach for Improving the Integrated Sensor Orientation
NASA Astrophysics Data System (ADS)
Mitishita, E.; Ercolin Filho, L.; Graça, N.; Centeno, J.
2016-06-01
The direct determination of exterior orientation parameters (EOP) of aerial images via integration of the Inertial Measurement Unit (IMU) and GPS is often used in photogrammetric mapping nowadays. The accuracies of the EOP depend on the accurate parameters related to sensors mounting when the job is performed (offsets of the IMU relative to the projection centre and the angles of boresigth misalignment between the IMU and the photogrammetric coordinate system). In principle, when the EOP values do not achieve the required accuracies for the photogrammetric application, the approach, known as Integrated Sensor Orientation (ISO), is used to refine the direct EOP. ISO approach requires accurate Interior Orientation Parameters (IOP) and standard deviation of the EOP under flight condition. This paper investigates the feasibility of use the in situ camera calibration to obtain these requirements. The camera calibration uses a small sub block of images, extracted from the entire block. A digital Vexcel UltraCam XP camera connected to APPLANIX POS AVTM system was used to get two small blocks of images that were use in this study. The blocks have different flight heights and opposite flight directions. The proposed methodology improved significantly the vertical and horizontal accuracies of the 3D point intersection. Using a minimum set of control points, the horizontal and vertical accuracies achieved nearly one image pixel of resolution on the ground (GSD). The experimental results are shown and discussed.
Khanage, Shantaram Gajanan; Mohite, Popat Baban; Jadhav, Sandeep
2013-01-01
Eperisone Hydrochloride (EPE) is a potent new generation antispasmodic drug which is used in the treatment of moderate to severe pain in combination with Paracetamol (PAR). Both drugs are available in tablet dosage form in combination with a dose of 50 mg for EPE and 325 mg PAR respectively. The method is based upon Q-absorption ratio method for the simultaneous determination of the EPE and PAR. Absorption ratio method is used for the ratio of the absorption at two selected wavelength one of which is the iso-absorptive point and other being the λmax of one of the two components. EPE and PAR shows their iso-absorptive point at 260 nm in methanol, the second wavelength used is 249 nm which is the λmax of PAR in methanol. The linearity was obtained in the concentration range of 5-25 μg/mL for EPE and 2-10 μg/mL for PAR. The proposed method was effectively applied to tablet dosage form for estimation of both drugs. The accuracy and reproducibility results are close to 100% with 2% RSD. RESULTS of the analysis were validated statistically and found to be satisfactory. The results of proposed method have been validated as per ICH guidelines. A simple, precise and economical spectrophotometric method has been developed for the estimation of EPE and PAR in pharmaceutical formulation.
Managing the Life Cycle Risks of Nanomaterials
2009-07-01
ISO International Organization for Standardization ISN Institute for Soldier Nanotechnologies LCA Life Cycle Assessment LCCA Life Cycle Cost Analysis...similar to their smaller Existing ISO /TS 27687:2008 Nanotechnologies -- Terminology and definitions for nano-objects -- Nanoparticle, nanofibre and...Nanotechnology Under Development ISO /CD TR 80004-1 Nanotechnologies - Terminology and definitions – Framework ISO /AWI TS 80004-2 Nanotechnologies
21 CFR 184.1165 - n-Butane and iso-butane.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false n-Butane and iso-butane. 184.1165 Section 184.1165 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD... Listing of Specific Substances Affirmed as GRAS § 184.1165 n-Butane and iso-butane. (a) n-Butane and iso...
ISO 9000 and Creativity: Potential Advantages of Implementing ISO in Community Colleges
ERIC Educational Resources Information Center
Alkeaid, Adel
2007-01-01
The purpose of this paper is to examine the relationship between the ISO 9000 standard and creativity. In this paper, the researcher tries to answer the following questions: Which learning theories best foster creative thought? Is creativity more behaviorist or constructivist? Where does ISO 9000 fit in the continuum from behaviorism to…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-14
... Transmission System Operator, Inc. (Midwest ISO or Respondent), alleging that Midwest ISO is requiring the Edison Wind Projects to satisfy the M3 milestone in contravention of the Midwest ISO's Tariff and the... served on the contacts for the Midwest ISO as listed on the Commission's list of Corporate Officials. Any...
The Relationship between the Training Function and ISO-9000 Registration.
ERIC Educational Resources Information Center
Maxwell, Randy C.; Jost, Karen L.
ISO 9000 is one of a series of international standards providing guidelines and governing quality of products and services. The ISO 9000 certification demonstrates the capability of a supplier to control the processes that determine the acceptability of the product or service being supplied. This paper focuses on the training aspects of ISO 9000…
CMMI(Registered) for Acquisition, Version 1.3. CMMI-ACQ, V1.3
2010-11-01
and Software Engineering – System Life Cycle Processes [ ISO 2008b] ISO /IEC 27001 :2005 Information technology – Security techniques – Information...International Organization for Standardization and International Electrotechnical Commission. ISO /IEC 27001 Information Technology – Security Techniques...International Organization for Standardization/International Electrotechnical Commission ( ISO /IEC) body of standards. CMMs focus on improving processes
21 CFR 184.1165 - n-Butane and iso-butane.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true n-Butane and iso-butane. 184.1165 Section 184.1165 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD... Listing of Specific Substances Affirmed as GRAS § 184.1165 n-Butane and iso-butane. (a) n-Butane and iso...
Iso-vector form factors of the delta and nucleon in QCD sum rules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozpineci, A.
Form factors are important non-perturbative properties of hadrons. They give information about the internal structure of the hadrons. In this work, iso-vector axial-vector and iso-vector tensor form factors of the nucleon and the iso-vector axial-vector {Delta}{yields}N transition form factor calculations in QCD Sum Rules are presented.
A/E/C Graphics Standard: Release 2.0 (formerly titled CAD Drafting Standard)
2015-08-01
Tables Table 2-1. ANSI and ISO sheet size comparison . ....................................................................................... 3... Comparison of font types. ......................................................................................................... 45 Table 5-2. Inch...used (ISO A0 may be used for large maps). Table 2-1 lists the standard sizes of ANSI and ISO sheets. Table 2-1. ANSI and ISO sheet size comparison
International Organization for Standardization (ISO) 15189.
Schneider, Frank; Maurer, Caroline; Friedberg, Richard C
2017-09-01
The College of American Pathologists (CAP) offers a suite of laboratory accreditation programs, including one specific to accreditation to the international organization for standardization (ISO) 15189 standard for quality management specific to medical laboratories. CAP leaders offer an overview of ISO 15189 including its components, internal audits, occurrence management, document control, and risk management. The authors provide a comparison of its own ISO 15189 program, CAP 15189, to the CAP Laboratory Accreditation Program. The authors conclude with why laboratories should use ISO 15189. © The Korean Society for Laboratory Medicine.
Biomechanics of the incudo-malleolar-joint - Experimental investigations for quasi-static loads.
Ihrle, S; Gerig, R; Dobrev, I; Röösli, C; Sim, J H; Huber, A M; Eiber, A
2016-10-01
Under large quasi-static loads, the incudo-malleolar joint (IMJ), connecting the malleus and the incus, is highly mobile. It can be classified as a mechanical filter decoupling large quasi-static motions while transferring small dynamic excitations. This is presumed to be due to the complex geometry of the joint inducing a spatial decoupling between the malleus and incus under large quasi-static loads. Spatial Laser Doppler Vibrometer (LDV) displacement measurements on isolated malleus-incus-complexes (MICs) were performed. With the malleus firmly attached to a probe holder, the incus was excited by applying quasi-static forces at different points. For each force application point the resulting displacement was measured subsequently at different points on the incus. The location of the force application point and the LDV measurement points were calculated in a post-processing step combining the position of the LDV points with geometric data of the MIC. The rigid body motion of the incus was then calculated from the multiple displacement measurements for each force application point. The contact regions of the articular surfaces for different load configurations were calculated by applying the reconstructed motion to the geometry model of the MIC and calculate the minimal distance of the articular surfaces. The reconstructed motion has a complex spatial characteristic and varies for different force application points. The motion changed with increasing load caused by the kinematic guidance of the articular surfaces of the joint. The IMJ permits a relative large rotation around the anterior-posterior axis through the joint when a force is applied at the lenticularis in lateral direction before impeding the motion. This is part of the decoupling of the malleus motion from the incus motion in case of large quasi-static loads. Copyright © 2015 Elsevier B.V. All rights reserved.
Mechanical Properties of Elastomeric Impression Materials: An In Vitro Comparison
De Angelis, Francesco; Caputi, Sergio; D'Amario, Maurizio; D'Arcangelo, Camillo
2015-01-01
Purpose. Although new elastomeric impression materials have been introduced into the market, there are still insufficient data about their mechanical features. The tensile properties of 17 hydrophilic impression materials with different consistencies were compared. Materials and Methods. 12 vinylpolysiloxane, 2 polyether, and 3 hybrid vinylpolyether silicone-based impression materials were tested. For each material, 10 dumbbell-shaped specimens were fabricated (n = 10), according to the ISO 37:2005 specifications, and loaded in tension until failure. Mean values for tensile strength, yield strength, strain at break, and strain at yield point were calculated. Data were statistically analyzed using one-way ANOVA and Tukey's tests (α = 0.05). Results. Vinylpolysiloxanes consistently showed higher tensile strength values than polyethers. Heavy-body materials showed higher tensile strength than the light bodies from the same manufacturer. Among the light bodies, the highest yield strength was achieved by the hybrid vinylpolyether silicone (2.70 MPa). Polyethers showed the lowest tensile (1.44 MPa) and yield (0.94 MPa) strengths, regardless of the viscosity. Conclusion. The choice of an impression material should be based on the specific physical behavior of the elastomer. The light-body vinylpolyether silicone showed high tensile strength, yield strength, and adequate strain at yield/brake; those features might help to reduce tearing phenomena in the thin interproximal and crevicular areas. PMID:26693227
Bond and fracture strength of metal-ceramic restorations formed by selective laser sintering
Bae, Eun-Jeong; Kim, Woong-Chul; Kim, Hae-Young
2014-01-01
PURPOSE The purpose of this study was to compare the fracture strength of the metal and the bond strength in metal-ceramic restorations produced by selective laser sintering (SLS) and by conventional casting (CAST). MATERIALS AND METHODS Non-precious alloy (StarLoy C, DeguDent, Hanau, Germany) was used in CAST group and metal powder (SP2, EOS GmbH, Munich, Germany) in SLS group. Metal specimens in the form of sheets (25.0 × 3.0 × 0.5 mm) were produced in accordance with ISO 9693:1999 standards (n=30). To measure the bond strength, ceramic was fired on a metal specimen and then three-point bending test was performed. In addition, the metal fracture strength was measured by continuing the application of the load. The values were statistically analyzed by performing independent t-tests (α=.05). RESULTS The mean bond strength of the SLS group (50.60 MPa) was higher than that of the CAST group (46.29 MPa), but there was no statistically significant difference. The metal fracture strength of the SLS group (1087.2 MPa) was lower than that of the CAST group (2399.1 MPa), and this difference was statistically significant. CONCLUSION In conclusion the balling phenomenon and the gap formation of the SLS process may increase the metal-ceramic bond strength. PMID:25177469
NASA Astrophysics Data System (ADS)
Kalaycıoğlu, Barış; Husnu Dirikolu, M.
2010-09-01
In this study, a Type III composite pressure vessel (ISO 11439:2000) loaded with high internal pressure is investigated in terms of the effect of the orientation of the element coordinate system while simulating the continuous variation of the fibre angle, the effect of symmetric and non-symmetric composite wall stacking sequences, and lastly, a stacking sequence evaluation for reducing the cylindrical section-end cap transition region stress concentration. The research was performed using an Ansys® model with 2.9 l volume, 6061 T6 aluminium liner/Kevlar® 49-Epoxy vessel material, and a service internal pressure loading of 22 MPa. The results show that symmetric stacking sequences give higher burst pressures by up to 15%. Stacking sequence evaluations provided a further 7% pressure-carrying capacity as well as reduced stress concentration in the transition region. Finally, the Type III vessel under consideration provides a 45% lighter construction as compared with an all metal (Type I) vessel.
Rolling Bearing Life Prediction-Past, Present, and Future
NASA Technical Reports Server (NTRS)
Zaretsky, E V; Poplawski, J. V.; Miller, C. R.
2000-01-01
Comparisons were made between the life prediction formulas of Lundberg and Palmgren, Ioannides and Harris, and Zaretsky and full-scale ball and roller bearing life data. The effect of Weibull slope on bearing life prediction was determined. Life factors are proposed to adjust the respective life formulas to the normalized statistical life distribution of each bearing type. The Lundberg-Palmgren method resulted in the most conservative life predictions compared to Ioannides and Harris, and Zaretsky methods which produced statistically similar results. Roller profile can have significant effects on bearing life prediction results. Roller edge loading can reduce life by as much as 98 percent. The resultant predicted life not only depends on the life equation used but on the Weibull slope assumed, the least variation occurring with the Zaretsky equation. The load-life exponent p of 10/3 used in the American National Standards Institute (ANSI)/American Bearing Manufacturers Association (ABMA)/International Organization for Standardization (ISO) standards is inconsistent with the majority roller bearings designed and used today.
Thiros, Susan A.; Gerner, Steven J.
2015-01-01
Irrigation improvements began to be implemented in 2007 to reduce dissolved-solids loads discharged from the MWSP area. The theoretical annual net dissolved-solids load where the cumulative NRCS calculated dissolved-solids load reduction is added to the net MWSP dissolved-solids load is what would be expected if there was no irrigation improvement in the area associated with the MWSP. The theoretical data points lie very near the baseline representing the pre-MWSP dissolved-solids load to canal streamflow relation. The proximity of the theoretical data points to the baseline shows that the NRCS calculations of reduction in dissolved-solids load are generally supported by the data collected during this study.
Orthodontic intrusion of maxillary incisors: a 3D finite element method study
Saga, Armando Yukio; Maruo, Hiroshi; Argenta, Marco André; Maruo, Ivan Toshio; Tanaka, Orlando Motohiro
2016-01-01
Objective: In orthodontic treatment, intrusion movement of maxillary incisors is often necessary. Therefore, the objective of this investigation is to evaluate the initial distribution patterns and magnitude of compressive stress in the periodontal ligament (PDL) in a simulation of orthodontic intrusion of maxillary incisors, considering the points of force application. Methods: Anatomic 3D models reconstructed from cone-beam computed tomography scans were used to simulate maxillary incisors intrusion loading. The points of force application selected were: centered between central incisors brackets (LOAD 1); bilaterally between the brackets of central and lateral incisors (LOAD 2); bilaterally distal to the brackets of lateral incisors (LOAD 3); bilaterally 7 mm distal to the center of brackets of lateral incisors (LOAD 4). Results and Conclusions: Stress concentrated at the PDL apex region, irrespective of the point of orthodontic force application. The four load models showed distinct contour plots and compressive stress values over the midsagittal reference line. The contour plots of central and lateral incisors were not similar in the same load model. LOAD 3 resulted in more balanced compressive stress distribution. PMID:27007765
Lee, Yoon-Bok; Lee, Hyong Joo; Won, Moo Ho; Hwang, In Koo; Kang, Tae-Cheon; Lee, Jae-Yong; Nam, Sang-Yoon; Kim, Kang-Sung; Kim, Eugene; Cheon, Sang-Hee; Sohn, Heon-Soo
2004-07-01
To investigate the protective activity of soy isoflavones on neurons, the effects of isoflavones on cholinergic enzyme activity, immunoreactivities of cholinergic enzyme, and delayed matching-to-place (DMP) performance were measured in normal elderly rats. Male Sprague-Dawley rats (n = 48; 10 mo old) were assigned to 3 groups: CD (control diet), ISO 0.3 (0.3 g/kg soy isoflavones diet), and ISO 1.2 (1.2 g/kg soy isoflavones diet). After 16 wk of consuming these diets, choline acetyltransferase (ChAT) activity in the ISO 0.3 group was greater in cortex and basal forebrain (BF; P < 0.05) than in controls. In BF, ChAT activity was also significantly greater in the ISO 1.2 group than in control rats. Acetylcholine esterase (AChE) activity in the ISO 0.3 group was significantly inhibited in cortex, BF, and hippocampus and in the ISO 1.2 group in cortex and hippocampus. Choline acetyltransferase immunoreactivity (ChAT-IR) in the ISO 1.2 group was significantly greater than in controls in the medial septum area. ChAT-IR in the ISO 0.3 and ISO 1.2 groups was significantly higher than in the CD group in the hippocampus CA1 area. Spatial DMP performance by the ISO 0.3 group showed significantly shorter swimming time than by the CD group. These findings show that soy isoflavones can influence the brain cholinergic system and reduce age-related neuron loss and cognition decline in male rats.
Reduced ischemia-reperfusion injury with isoproterenol in non-heart-beating donor lungs.
Jones, D R; Hoffmann, S C; Sellars, M; Egan, T M
1997-05-01
Transplantation of lungs retrieved from non-heart-beating donors could expand the donor pool. Recent studies suggest that the ischemia-reperfusion injury (IRI) to the lung can be attenuated by increasing intracellular cAMP concentrations. The purpose of this study was to determine the effect of IRI on capillary permeability, as measured by Kfc, in lungs retrieved from non-heart-beating donors and reperfused with or without isoproterenol (iso). Using an in situ isolated perfused lung model, lungs were retrieved from non-heart-beating donor rats ventilated with O2 or not at varying intervals after death. The lungs were reperfused with or without iso (10 microM). Kfc, lung viability, and pulmonary hemodynamics were measured, and tissue levels of adenine nucleotides and cAMP were measured by HPLC. Iso-reperfusion decreased Kfc significantly (P < 0.05) compared to non-iso-reperfused groups at all postmortem ischemic times, irrespective of preharvest ventilation status. Pulmonary arterial pressures and resistances increased and venous resistances decreased with iso-reperfusion. Total adenine nucleotide (TAN) levels correlated with Kfc in non-iso-reperfused (r = 0.65) and iso-perfused (r = 0.84) lungs. cAMP levels increased significantly with iso-reperfusion. cAMP levels correlated with Kfc (r = 0.87) in iso-reperfused lungs. Iso-reperfusion of lungs retrieved from non-heart-beating donor rats results in decreased capillary permeability and increased lung tissue cAMP levels. Pharmacologic augmentation of tissue TAN and cAMP levels may further ameliorate the increased capillary permeability seen in lungs retrieved from non-heart-beating donors.
NASA Astrophysics Data System (ADS)
Wu, Renguang; Cao, Xi
2017-06-01
The present study contrasts interannual variations in the intensity of boreal summer 10-20-day and 30-60-day intraseasonal oscillations (ISOs) over the tropical western North Pacific and their factors. A pronounced difference is found in the relationship of the two ISOs to El Niño-Southern Oscillation. The 10-20-day ISO intensity is enhanced during El Niño developing summer, whereas the 30-60-day ISO intensity is enhanced during La Niña decaying summer. The above different relationship is interpreted as follows. The equatorial central and eastern Pacific SST anomalies modify vertical wind shear, lower-level moisture, and vertical motion in a southeast-northwest oriented band from the equatorial western Pacific to the tropical western North Pacific where the 10-20-day ISOs originate and propagate. These background field changes modulate the amplitude of 10-20-day ISOs. Preceding equatorial central and eastern Pacific SST anomalies induce SST anomalies in the North Indian Ocean in summer, which in turn modify vertical wind shear and vertical motion over the tropical western North Pacific. The modified background fields influence the amplitude of the 30-60-day ISOs when they reach the tropical western North Pacific from the equatorial region. A feedback of ISO intensity on local SST change is identified in the tropical western North Pacific likely due to a net effect of ISOs on surface heat flux anomalies. This feedback is more prominent from the 10-20-day than the 30-60-day ISO intensity change.
Kim, Yusung; Tomé, Wolfgang A
2008-01-01
Voxel based iso-Tumor Control Probability (TCP) maps and iso-Complication maps are proposed as a plan-review tool especially for functional image-guided intensity-modulated radiotherapy (IMRT) strategies such as selective boosting (dose painting) and conformal avoidance IMRT. The maps employ voxel-based phenomenological biological dose-response models for target volumes and normal organs. Two IMRT strategies for prostate cancer, namely conventional uniform IMRT delivering an EUD = 84 Gy (equivalent uniform dose) to the entire PTV and selective boosting delivering an EUD = 82 Gy to the entire PTV, are investigated, to illustrate the advantages of this approach over iso-dose maps. Conventional uniform IMRT did yield a more uniform isodose map to the entire PTV while selective boosting did result in a nonuniform isodose map. However, when employing voxel based iso-TCP maps selective boosting exhibited a more uniform tumor control probability map compared to what could be achieved using conventional uniform IMRT, which showed TCP cold spots in high-risk tumor subvolumes despite delivering a higher EUD to the entire PTV. Voxel based iso-Complication maps are presented for rectum and bladder, and their utilization for selective avoidance IMRT strategies are discussed. We believe as the need for functional image guided treatment planning grows, voxel based iso-TCP and iso-Complication maps will become an important tool to assess the integrity of such treatment plans.
Integrated management system: The integration of ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000
NASA Astrophysics Data System (ADS)
Muzaimi, Hafizzudin; Chew, Boon Cheong; Hamid, Syaiful Rizal
2017-03-01
The implementation of integrated management system (IMS) for better quality management has become a preference for many organizations. This can be seen as many organizations used the combination of quality ISO 9001, an environment ISO 14001 and occupational health and safety management system OHSAS 18001 as a core for the IMS that largely implemented. Besides, the linked between quality management with risk management system need to be identified as the management system that enhance the effectiveness of IMS. Therefore, the risk management system ISO 31000 also presented as a part of integration. In nowadays competitive environment, the increasing pressure and needs from customer or stakeholders make it compulsory for the organization to propose the new system and standards. This paper presents and discusses about the benefit of integration, the management system components that can be converged and the implementation approach. A series of interview was conducted through in-depth interviews with 8 experts in this field, while data collected were analyzed qualitatively. The results consist of 16 factors of IMS implementation that have been identified and the use of PDCA approach for an effective implementation of IMS. As a conclusion, the paper proposes the integration of four management systems (ISO 9001, ISO 14001, OHSAS 18001 and ISO 31000) and on how the IMS can be used to structure the process of management for quality management towards sustainability practices in the organization.
Yang, Jianhong; Zhou, Yongzhao; Cheng, Xia; Fan, Yi; He, Shichao; Li, Shucai; Ye, Haoyu; Xie, Caifeng; Wu, Wenshuang; Li, Chunyan; Pei, Heying; Li, Luyuan; Wei, Zhe; Peng, Aihua; Wei, Yuquan; Li, Weimin; Chen, Lijuan
2015-01-09
To overcome drug resistance caused by apoptosis deficiency in patients with non-small cell lung carcinoma (NSCLC), there is a need to identify other means of triggering apoptosis-independent cancer cell death. We are the first to report that isogambogenic acid (iso-GNA) can induce apoptosis-independent autophagic cell death in human NSCLC cells. Several features of the iso-GNA-treated NSCLC cells indicated that iso-GNA induced autophagic cell death. First, there was no evidence of apoptosis or cleaved caspase 3 accumulation and activation. Second, iso-GNA treatment induced the formation of autophagic vacuoles, increased LC3 conversion, caused the appearance of autophagosomes and increased the expression of autophagy-related proteins. These findings provide evidence that iso-GNA induces autophagy in NSCLC cells. Third, iso-GNA-induced cell death was inhibited by autophagic inhibitors or by selective ablation of Atg7 and Beclin 1 genes. Furthermore, the mTOR inhibitor rapamycin increased iso-GNA-induced cell death by enhancing autophagy. Finally, a xenograft model provided additional evidence that iso-GNA exhibited anticancer effect through inducing autophagy-dependent cell death in NSCLC cells. Taken together, our results demonstrated that iso-GNA exhibited an anticancer effect by inducing autophagy-dependent cell death in NSCLC cells, which may be an effective chemotherapeutic agent that can be used against NSCLC in a clinical setting.
ISO 9001 certification for hospitals in Bulgaria: does it help service?
Stoimenova, Assena; Stoilova, Ani; Petrova, Guenka
2014-03-04
The aim of our study is to review the published literature on establishment and implementation of ISO 9001 QMS in European hospitals, to study the availability of International Organization for Standardization (ISO) quality management systems (QMS) in Bulgarian hospitals and to outline the main advantages of ISO implementation in the hospitals in Bulgaria. The information on availability of ISO QMS in the hospitals in Bulgaria was gathered via Bulgarian certification register, the registries of various quality associations, websites of hospitals and certification companies presented in Bulgaria. A total number of 312 hospitals in Bulgaria were screened for the availability of QMS certified against the ISO 9001 requirements. The experience of European hospitals that implemented QMS is positive and the used approaches to improve the processes and the demonstrated effects from ISO implementation are analysed by the researchers. Unlike other European Union member states, the establishment of quality management systems in Bulgaria is not compulsory. However, our study revealed that 14.42% of the hospitals in Bulgaria have implemented and have certified quality systems against the requirements of ISO 9001. Our study confirmed that a quality management system using the ISO 9001 standard is useful for the hospitals as it can help to increase the operational efficiencies, to reduce errors, improve patient safety and produce a more preventive approach instead of a reactive environment.
Wu, Xueyun; Yang, Dong; Zhu, Xiangcheng; Feng, Zhiyang; Lv, Zhengbin; Zhang, Yaozhou; Shen, Ben; Xu, Zhinan
2011-01-01
The heterologous production of iso-migrastatin (iso-MGS) was successfully demonstrated in an engineered S. lividans SB11002 strain, which was derived from S. lividans K4–114, following introduction of pBS11001, which harbored the entire mgs biosynthetic gene cluster. However, under similar fermentation conditions, the iso-MGS titer in the engineered strain was significantly lower than that in the native producer - Streptomyces platensis NRRL 18993. To circumvent the problem of low iso-MGS titers and to expand the utility of this heterologous system for iso-MGS biosynthesis and engineering, systematic optimization of the fermentation medium was carried out. The effects of major components in the cultivation medium, including carbon, organic and inorganic nitrogen sources, were investigated using a single factor optimization method. As a result, sucrose and yeast extract were determined to be the best carbon and organic nitrogen sources, resulting in optimized iso-MGS production. Conversely, all other inorganic nitrogen sources evaluated produced various levels of inhibition of iso-MGS production. The final optimized R2YE production medium produced iso-MGS with a titer of 86.5 mg/L, about 3.6-fold higher than that in the original R2YE medium, and 1.5 fold higher than that found within the native S. platensis NRRL 18993 producer. PMID:21625393
Yang, Jianhong; Zhou, Yongzhao; Cheng, Xia; Fan, Yi; He, Shichao; Li, Shucai; Ye, Haoyu; Xie, Caifeng; Wu, Wenshuang; Li, Chunyan; Pei, Heying; Li, Luyuan; Wei, Zhe; Peng, Aihua; Wei, Yuquan; Li, Weimin; Chen, Lijuan
2015-01-01
To overcome drug resistance caused by apoptosis deficiency in patients with non-small cell lung carcinoma (NSCLC), there is a need to identify other means of triggering apoptosis-independent cancer cell death. We are the first to report that isogambogenic acid (iso-GNA) can induce apoptosis-independent autophagic cell death in human NSCLC cells. Several features of the iso-GNA-treated NSCLC cells indicated that iso-GNA induced autophagic cell death. First, there was no evidence of apoptosis or cleaved caspase 3 accumulation and activation. Second, iso-GNA treatment induced the formation of autophagic vacuoles, increased LC3 conversion, caused the appearance of autophagosomes and increased the expression of autophagy-related proteins. These findings provide evidence that iso-GNA induces autophagy in NSCLC cells. Third, iso-GNA-induced cell death was inhibited by autophagic inhibitors or by selective ablation of Atg7 and Beclin 1 genes. Furthermore, the mTOR inhibitor rapamycin increased iso-GNA-induced cell death by enhancing autophagy. Finally, a xenograft model provided additional evidence that iso-GNA exhibited anticancer effect through inducing autophagy-dependent cell death in NSCLC cells. Taken together, our results demonstrated that iso-GNA exhibited an anticancer effect by inducing autophagy-dependent cell death in NSCLC cells, which may be an effective chemotherapeutic agent that can be used against NSCLC in a clinical setting. PMID:25571970
Software And Systems Engineering Risk Management
2010-04-01
RSKM 2004 COSO Enterprise RSKM Framework 2006 ISO/IEC 16085 Risk Management Process 2008 ISO/IEC 12207 Software Lifecycle Processes 2009 ISO/IEC...1 Software And Systems Engineering Risk Management John Walz VP Technical and Conferences Activities, IEEE Computer Society Vice-Chair Planning...Software & Systems Engineering Standards Committee, IEEE Computer Society US TAG to ISO TMB Risk Management Working Group Systems and Software
Environmental Analytical Measurement Uncertainty Estimation: Nested Hierarchical Approach
2001-01-01
recognized. The International Organization of Standardization ( ISO / IEC 17025 ) standard for the general requirements for competence of testing and...Uncertainty in Measurement” (GUM) was published by the International Organization of Standardization ( ISO ) in collaboration with the seven member...the American National Standards Institute (ANSI) adoption of the ISO GUM. The ANSI adoption of the ISO GUM provides the mathematical model and
An Evaluation Methodology for the Usability and Security of Cloud-based File Sharing Technologies
2012-09-01
FISMA, ISO 27001 , FIPS 140-2, and ISO 270001) indicate a cloud-based service’s compliance with industry standard security controls, management and...Information Assurance IEEE Institute of Electrical and Electronics Engineers IT Information Technology ITS Insider Threat Study ISO International...effectively, efficiently and with satisfaction” (International Organization for Standardization [ ISO ], 1998). Alternately, information security
2010-08-22
practice for information security management ( ISO /IEC 27002 ),” “Information technology — Security techniques — Information security management...systems —Requirements ( ISO /IEC 27002 ),”, “Information technology — Security techniques — Information security risk management ( ISO /IEC 27005).” from...associated practice aids. Perhaps the most germane discovery from this effort was a draft ISO standard on Systems and software engineering, Systems and
Merlin, Fabrício Kurman; Pereira, Vera Lúciaduarte do Valle; Pacheco, Waldemar
2012-01-01
Organizations are part of an environment in which they are pressured to meet society's demands and acting in a sustainable way. In an attempt to meet such demands, organizations make use of various management tools, among which, ISO standards are used. Although there are evidences of contributions provided by these standards, it is questionable whether its parameters converge for a possible induction for sustainable development in organizations. This work presents a theoretical study, designed on structuralism world view, descriptive and deductive method, which aims to analyze the convergence of management tools' parameters in ISO standards. In order to support the analysis, a generic framework for possible convergence was developed, based on systems approach, linking five ISO standards (ISO 9001, ISO 14001, OHSAS 18001, ISO 31000 and ISO 26000) with sustainable development and positioning them according to organization levels (strategic, tactical and operational). The structure was designed based on Brundtland report concept. The analysis was performed exploring the generic framework for possible convergence based on Nadler and Tushman model. The results found the standards can contribute to a possible sustainable development induction in organizations, as long as they meet certain minimum conditions related to its strategic alignment.
ISO radiation sterilization standards
NASA Astrophysics Data System (ADS)
Lambert, Byron J.; Hansen, Joyce M.
1998-06-01
This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."
Zaja-Milatovic, Snjezana; Gupta, Ramesh C.; Aschner, Michael; Montine, Thomas J.; Milatovic, Dejan
2008-01-01
Intense seizure activity associated with status epilepticus and excitatory amino acid (EAA) imbalance initiates oxidative damage and neuronal injury in CA1 of the ventral hippocampus. We tested the hypothesis that dendritic degeneration of pyramidal neurons in the CA1 hippocampal area resulting from seizure-induced neurotoxicity is modulated by cerebral oxidative damage. Kainic acid (KA, 1 nmol/5 μl) was injected intracerebroventricularly to C57Bl/6 mice. F2-isoprostanes (F2-IsoPs) and F4-neuroprostanes (F4-NeuroPs) were used as surrogate measures of in vivo oxidative stress and biomarkers of lipid peroxidation. Nitric oxide synthase (NOS) activity was quantified by evaluating citrulline level and pyramidal neuron dendrites and spines were evaluated using rapid Golgi stains and a Neurolucida system. KA produced severe seizures in mice immediately after its administration and a significant (p<0.001) increase in F2-IsoPs, F4-NeuroPs and citrulline levels were seen 30 min following treatment. At the same time, hippocampal pyramidal neurons showed significant (p<0.001) reduction in dendritic length and spine density. In contrast, no significant change in neuronal dendrite and spine density or F2-IsoP, F4-NeuroPs and citrulline levels were found in mice pretreated with Vitamin E (α-tocopherol, 100 mg/kg, ip) for 3 days, or with N-tert-butyl-α-phenylnitrone (PBN, 200 mg/kg, ip) or ibuprofen (inhibitors of cyclooxygenase, COX, 14 μg/ml of drinking water) for 2 weeks prior to KA treatment. These findings indicate novel interactions among free radical-induced generation of F2-IsoPs and F4-NeuroPs, nitric oxide and dendritic degeneration, closely associate oxidative damage to neuronal membranes with degeneration of the dendritic system, and point to possible interventions to limit severe damage in acute neurological disorders. PMID:18556069
ISO9000 and the quality management system in the digital hospital.
Liu, Yalan; Yao, Bin; Zhang, Zigang
2002-01-01
ISO9000 quality management system (ISO9000QMS) emphasize on the customer-oriented, managers' leadership and all staff's joining, adopt the process method and system management, spread the taking facts as a basis to make decision and improve consistently, and establish win-win relation with the suppliers. So, the digital hospital can adopt the ISO9000QMS. In order to establish the ISO9000QMS, the digital hospital should: (1) Design integrally, including analyzing the operation procedure, clarifying the job duties, setting up the spreading team and setting the quality policy and objectives: (2) Learning the ISO9000 quality standards; (3) Drawing up the documents, including the quality manual, program files and operation guiding files; (4) Training according the documents; (5) Executing the quality standard, including the service quality auditing, quality record auditing and quality system auditing; (6) Improving continually. With the establishment of ISO900QMS, the digital hospital can appraise more accurately, analyze quality matters statistically and avoid the interference of artificial factors.
Novel Musculoskeletal Loading and Assessment System
NASA Technical Reports Server (NTRS)
Downs, Meghan E.
2017-01-01
Ground based and ISS (International Space Station) exercise research have shown that axial loading via two-point loading at the shoulders and load quality (i.e. consistent load and at least 1:1 concentric to eccentric ratio) are extremely important to optimize musculoskeletal adaptations to resistance exercise. The Advanced Resistance Exercise Device (ARED) is on ISS now and is the "state of the art" for resistance exercise capabilities in microgravity; however, the ARED is far too large and power consuming for exploration vehicles. The single cable exercise device design selected for MPCV (Multi-Purpose Crew Vehicle), does not readily allow for the two-point loading at the shoulders.
Development of ISO connection-oriented/correctionless gateways
NASA Technical Reports Server (NTRS)
Landweber, Lawrence H.
1991-01-01
The project had two goals, establishment of a gateway between French and U.S. academic networks and studies of issues related to the development of ISO connection-oriented/connectionless (CO/CL) gateways. The first component involved installation of a 56K bps line between Princeton Univ. and INRIA in France. The end-points of these lines were connected by Vitalink link level bridges. The Princeton end was then connected to the NSFNET via the John Von Neumann Supercomputer Center. The French end was connected to Transpac, the French X.25 public data network and to the French IP research internet. U.S. users may communicate with users of the French internet by e-mail and may access computational and data resources in France by use of remote login and file transfer. The connection to Transpac enables U.S. users to access the SIMBAD astronomical database outside of Paris. Access to this database from the U.S. can be via TCP/IP or DECNET (via a DECNET to TCP/IP gateway) protocols utilizing a TCP/IP to X.25 gateway developed and operated by INRIA. The second component of the project involved experiments aimed at understanding the issues involved is ISO CO/CL gateways. An experimental gateway was developed at Wisconsin and a preliminary report was prepared. Because of the need to devote most resources to the first component of the project, work in this area did not go beyond development of a prototype gateway.
New water and remote galaxies complete ISO's observations
NASA Astrophysics Data System (ADS)
ISO's operational teams at ESA's ground station at Villafranca near Madrid have been hurrying to provide the world's astronomers with as many observations as possible. They have long anticipated the exhaustion of ISO's vital supply of liquid helium, which cooled the infrared telescope and its instruments to their operating temperatures, close to absolute zero. Two weeks after ISO was put into orbit on 17 November 1995 by an Ariane 44P launcher, the external parts of the cooling system had settled to the operating temperature. The specification required that ISO should then operate for at least 18 months -- implying that operations might have to end in May 1997. Thanks to superb engineering by European industry, which built the spacecraft and its super-cool telescope, ISO has given astronomers almost a year longer than that. During the extra time the count of ISO's observations of cosmic objects has risen from 16,000 to about 26,000. Among the benefits of ISO's longevity has been the chance to examine an important region of the sky, in and around the constellation of Orion. This was not accessible in the nominal mission but has now been observed in two periods. Four inter national teams, supported by national funding agencies, supplied the instruments to analyse the infrared rays received by ISO's telescope. The principal investigators leading the teams are Dietrich Lemke (Heidelberg, Germany) for the versatile photometer ISOPHOT, Catherine Cesarsky (Saclay, France) for the camera ISOCAM, Thijs de Graauw (Groningen, the Netherlands) for the Short Wavelength Spectrometer SWS, and Peter Clegg (London, UK) for the Long Wavelength Spectrometer LWS. Water vapour on Titan A big difference between ISO and the only previous infrared astronomy satellite (IRAS 1983) has been its ability to examine individual objects across a wide range of accurately defined infrared wavelengths. Many spectra showing patterns of intensities at the different wavelengths have enabled astronomers to deduce the presence of diverse materials in interstellar space, in the surroundings of stars, and in other galaxies. As previously reported, ISO has identified stony materials, tarry compounds of carbon, and vapours and ices like water and carbon monoxide. Together they give the first clear picture of how Mother Nature prepares, from elements manufactured in stars, the ingredients needed for planets and for life itself. Particularly striking for the human imagination are ISO's repeated discoveries of water in the deserts of space. They encourage expectations of life elsewhere in the Universe. Water has turned up around dying stars, newborn stars, in the general interstellar medium, in the atmospheres of the outer planets and in other galaxies too. A link to the Earth's oceans and the water we live by comes in the water- ice long known to be a major ingredient of comets, which are relics from the era of planet-building. A further link to the investigation of the origin of life is the apparent detection of water vapour in the mysterious atmosphere of Saturn's largest moon, Titan. A preliminary announcement comes from an international team headed by Athena Coustenis of Paris Observatory and Alberto Salama of the ISO Science Operations Center at Villafranca. The team used ISO's Short Wavelength Spectrometer during several hours of observations last December, when Titan was at its farthest from Saturn as seen by ISO. Emissions at wavelengths of 39 and 44 microns showed up, as an expected signature of water vapour. The news will excite the scientists involved in ESA's probe Huygens, launched last year aboard NASA's Cassini spacecraft. It will parachute into Titan's atmosphere to see what the chemistry of the Earth may have been like before life began. "Water vapour makes Titan much richer," comments Athena Coustenis. "We knew there was carbon monoxide and carbon dioxide in Titan's atmosphere, so we expected water vapour too. Now that we believe we've found it, we can expect to better understand the organic chemistry taking place on Titan and also the sources of oxygen in the Saturnian System. After ISO, the Huygens probe will reveal the actual degree of complexity in a mixture of elaborate organic molecules closely resembling the chemical soup on the young Earth." Ballet corps of young stars Infrared images of the spectacular Orion star-forming regions, at a distance of approximately 1500 light years, are bonuses from ISO's extended life. In the Horsehead Nebula, visible light shows a large dark dust cloud from which a black wisp shaped like a horse's head protrudes into a luminous cloud of gas. When seen by ISO's camera ISOCAM, dense parts of the dusty region appear as shiny filaments and the horse's head almost disappears. Young stars are detected in the horse's forehead and in the nearby nebula NGC 2023. Other well-known nebulae in the Orion region include NGC 2068 and NGC 2071. Emission by carbon compounds (polycyclic aromatic hydrocarbons or PAH) makes the infrared nebulae spectacular, as seen by ISOCAM. And thanks to ISOCAM's sensitivity and the ability of infrared rays to penetrate a dust cloud better than visible light, ballet corps of young stars appear on the stage, seen as spots in the centre of these two nebulae. This is not surprising, because the dense, dusty regions called molecular clouds are often the breeding grounds of new stars, but ISOCAM detects fainter and more obscured objects. "We have used ISOCAM to make a census of families of young stars," comment Lennart Nordh and Göran Olofsson of Stockholm University, who lead a team of astronomers from Sweden, France, Italy, the UK and ESA. "By comparing the intensities of the point-like objects at different infrared wavelengths we can efficiently identify the ensemble of young stars still embedded in its parental molecular clouds." From their study of ISO's early observations of four star-forming clouds, the astronomers report the detection of small stars. "Almost 300 young stars have been identified to date, many of which were previously not recognized," Nordh and Olofsson say. "Most of the latter objects have luminosities 10-100 times lower than revealed by earlier observations. Our preliminary analysis indicates that at least ten per cent of the embedded young stars will become small brown dwarfs, or ownerless super-planets, less than one-tenth of the mass of the Sun." Colliding galaxies Some galaxies are unusually bright in the infrared because of cosmic traffic accidents that bring them into collision with other galaxies. The result is a frenzy of star formation called a starburst. The explosion of short-lived stars then creates a pall of warm dust which ISO observes in the infrared. The relative intensities of different wavelengths enable astronomers to distinguish starburst events from other sources of strong infrared rays, such as the environment of a black hole in the nucleus of a galaxy. Collisions and starbursts play an important part in the evolution of galaxies. A famous pair of colliding galaxies called the Antennae was one of the first objects to be examined by ISO. Continuing study of the Antennae over the past two years has revealed a clear picture of a starburst occurring exactly where the dense disks of the galaxies intersect. The nuclei of the two galaxies are plainly distinguished too. Centaurus A is a galaxy that first attracted the attention of astronomers by its strong of radio emissions. In its visible appearance, a large, round (elliptical) galaxy has a dark band across its face. This too turns out to be the result of a galactic collision. The dark band is a flat, disk-shaped galaxy seen almost edge-on. Centaurus A is the nearest case of a phenomenon seen elsewhere by ISO, in which a flat galaxy has merged with an elliptical galaxy while preserving its flat configuration. ISOCAM gives an image of Centaurus A in which the disk galaxy is the more conspicuous object. The orientation of the disk becomes clear. It is at right angles to the axis of the radio-emitting regions, which are powered by jets of electrons driven by a black hole in the centre of the galaxy. Excited emissions detected by ISO's Short Wavelength Spectrometer also indicate the presence of an active black hole. "Centaurus A is an example of ISO's magic," says Catherine Cesarsky of CEA Saclay in France, leader of the ISOCAM instrument team. "It transforms opaque clouds seen by visible light into glowing scenes in the infrared. The same thing happens in dust clouds hiding newborn stars, and on a huge scale in dusty starburst galaxies -- which become infrared beacons lighting our way deep into the Universe." Distant galaxies seen through the holes in the sky When ISO was launched, one of the hopes for the space observatory was that it would detect galaxies made luminous by starburst events, or by black-hole activity, very far away in space and therefore far back in time. Dust in our own Milky Way Galaxy usually obscures the remotest and faintest galaxies. But when they look northwards and southwards, at right-angles to the disk of the Milky Way, astronomers find holes in the dust clouds through which distant galaxies are discernible. Both for ISO and the Hubble Space Telescope these holes have been special targets for observations with long exposures, to reveal faint galaxies. ISOCAM results through the northern hole, by a Japanese-led team, were reported last year in an ESA Information Note (25.97) and a picture release (ESA/ISO 97:8/1). They revealed many infrared-luminous galaxies billions of light- years away, from an era corresponding with about half the present age of the Universe. Even more distant and earlier galaxies may be present in ISO's observations, including some objects not yet seen by visible light. Results released at the London press briefing on ISO include "deep field" examinations by groups of astronomers led by Catherine Cesarsky of CEA Saclay and Michael Rowan Robinson of Imperial College, London, analysing the northern and southern images respectively. In the northern deep field, when ISOCAM observations are superimposed on a Hubble picture of the same region, they pick out spiral galaxies experiencing starbursts. A different signature comes from large elliptical galaxies whose visible light has been shifted into the infrared by the expansion of the Universe. The astronomers estimate that some of the objects seen by ISOCAM are so far away that the Universe was only one-third of its present age when they emitted the radiation seen today. The first ISO images from the opposite direction in the sky, in the southern deep field, show similar objects, again at great distances. A preliminary analysis indicates the presence of of 30-40 remote galaxies seen at a wavelength of 7 microns and 22-30 at 15 microns. One interesting source, bright in the infrared, is not seen by visible light even in a prolonged examination by the CTIO 4-metre telescope in Chile (A. Walker). Astronomers suspect that this object is undergoing an especially violent period of star formation. The interpretation can be checked when Hubble and other telescopes have a chance to examine this scene. Besides illuminating the evolution of the galaxies, ISO's deep field results are encouraging for scientists planning another of ESA's astronomical space projects, FIRST. Its longer wavelengths will penetrate even deeper into the unknown. Non-stop discoveries The extended life was not the only outcome that made ISO a triumph for ESA, European industry and those responsible for its operations. The pointing accuracy of the telescope turned out to be ten times better than required in the specification and its jitter was one-fifth of what was considered tolerable. Stray light in the optical system was too small to measure. The scheduling systems achieved science observations for 90-95 per cent of the available time. Much of the rest of the time, when ISO was turning to new targets, was spent in mapping parts of the sky at a wavelength of 200 microns. Activity concerning ISO will continue at the Villafranca ground station until the year 2001, long after the completion of the observational phase of the mission. During the space operations, the main objective was to make as many observations as possible. Thorough analysis and interpretation of the results will take several years. "We still have plenty to do," says Martin Kessler, ESA's project scientist for ISO. "Our team at Villafranca is preparing a complete archive of ISO data on 500-1000 compact disks, after reprocessing with improved software. We'll release part of this archive to the world-wide astronomical community in the autumn of this year, and the rest in 1999. We shall also advise the astronomers who have used ISO, about the particular requirements for handling the data from each instrument, and we'll be doing some astronomy ourselves. There are far more results still to come from ISO." Europe's infrared astronomers are already busy preparing ESA's FIRST and Planck missions, due for launch early in the new century. FIRST will observe long infrared wavelengths in the sub-millimetre range, while Planck will map the cosmic microwave background far more accurately than NASA's COBE mission did, to reveal the clumps of matter from which galaxies evolved. Also under study by ESA is a possible interferometer mission using a combination of infrared telescopes. In principle it might observe and characterize planets in orbit around other stars. Meanwhile, Europe's space astronomy programme continues apace in other directions. ESA's participation in the Hubble Space Telescope and its eventual successor assures access to those important instruments for Europe's astronomers. The release in 1997 of the catalogues from ESA's unique star-mapping mission Hipparcos provided all astronomer with amazingly precise data for sizing up the stars and the wider Universe. Next year will see the launch of ESA's XMM satellite to observe X-rays from the Universe with the most ingenious and sensitive X-ray telescopes ever made. It will be followed by Integral in 2001, which will investigate cosmic gamma-rays with clever imaging devices called coded masks, and ultra-sensitive detectors. "Our aim in space astronomy is that every ESA mission should be the best in the world at the time of its launch," says Roger Bonnet, ESA's director of science. "ISO is a shining example. It has revolutionized infrared astronomy. It has given us wonderful insights into cool and hidden places in the Universe, and into the origins of water and other materials to which we owe our very existence. A mission of this scale and complexity was feasible for Europe only through the multinational collaboration coordinated by ESA." See ISO's results on the World Wide Web, or on a CD Immediate access to information about ISO and its results, including a picture gallery, is available via the Internet: http://isowww.estec.esa.nl For the assistance of journalists, ESA's ISO team has also prepared a compact disk containing the same information as the website, together with previously published information about ISO and its results. For further information, contact ESA Public Relations Division Tel: +33.(0)1.53.69.71.55 Fax: +33(0)1.53.69.76.90
Survey of U.S. Ancillary Services Markets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Zhi; Levin, Todd; Conzelmann, Guenter
In addition to providing energy to end-consumers, power system operators are also responsible for ensuring system reliability. To this end, power markets maintain an array of ancillary services to ensure that it is always possible to balance the supply and demand for energy in real-time. A subset of these ancillary services are commonly procured through market-based mechanisms: namely, Regulation, Spinning, and Non-spinning Reserves. Regulation Reserves are maintained to respond to supply/demand imbalances over short time frames, typically on the order of several seconds to one minute. Resources that provide Regulation Reserves adjust their generation or load levels in response tomore » automatic generation control (AGC) signals provided by the system operator. Contingency reserves are maintained to provide additional generation capacity in the event that load increases substantially or supply side resources reduce their output or are taken offline. The reserves are typically segmented into two categories, 1) Spinning or Synchronized Reserves that are provided by generation units that are actively generating and have the ability to increase or decrease their output, 2) Non-spinning or Non-synchronized Reserves that are provided by generation resources that are not actively generating, but are able to start up and provide generation within a specified timeframe. Contingency reserves typically have response times on the order of ten to 30 minutes and can also be provided by demand-side resources that are capable of reducing their load. There are seven distinct power markets in the United States, each operated by a Regional Transmission Operator (RTO) or Independent System Operator (ISO) that operates the transmission system in its territory, operates markets for energy and ancillary services, and maintains system reliability. Each power market offers its own set of ancillary services, and precise definitions, requirements, and market mechanisms differ between markets. Despite the differences between markets, both in terms of services offered and system requirements, some broad trends generally apply. Regulation Reserves typically have the highest market prices, followed by Spinning Reserves and Non-spinning Reserves. Prices for Regulation Reserves have been the highest in the PJM market, since it opened in October 2012. This is partially because PJM experienced large price spikes during the period of extreme weather conditions in early 2014. ERCOT has traditionally had the highest prices for Spinning Reserves (called Responsive Reserves in ERCOT), including several periods of sustained high prices between 2010 and 2012. This can be explained in part by the relatively high penetration of variable wind resources and a similarly high requirement relative to peak load. ERCOT has also traditionally had the highest price for Non-spinning Reserves, followed by the NYISO East region. Both have experienced several periods of prolonged high prices since their inception, an occurrence that has not been regularly seen in other markets. In ISO-NE and PJM for example, the market clearing price for Non-spinning Reserves is typically $0/MWh more than 95% of the time. Market volume (in terms of the average amount of capacity of each service that is provided to a system) typically follows the reverse order of prices, as systems maintain the most Non-spinning Reserves capacity followed by Spinning Reserves and Regulation Reserves. PJM generally has the largest market for Regulation Reserves both in terms of capacity. The size of most Regulation Reserves markets in terms of capacity stay relatively constant year-to-year, as this is dictated largely by system requirements. PJM also generally has the largest Spinning Reserves market in terms of capacity. SPP, MISO, ISO-NE and SPP (beginning in 2014) all have Spinning Reserve markets with similar average capacity levels. When combined, the markets for Non-spinning and Operating reserves in ISO-NE have a comparable capacity to the market for Primary Reserves 1 in PJM. SPP, MISO, and CAISO all have smaller markets for their respective Non-spinning Reserves products that are roughly the same size as each other in terms of capacity.« less
Quantification of umu genotoxicity level of urban river water.
Kameya, T; Nagato, T; Nakagawa, K; Yamashita, D; Kobayashi, T; Fujie, K
2011-01-01
In recent years, the request of environmental safety management for carcinogenic substances, mutagenic substances and/or reproductive toxicity substances (CMR) has increased. This study focused on clarifying the genotoxicity level of environmental water and its release source by using the umu test provided in ISO13829. Although a genotoxicity index "induction ratio (IR)" is used in ISO13829, we normalised it to make it possible to compare various environmental water quantitatively to each other as a new index "genotoxic activity (GA=(IR-1)/Dose)". Sample water was collected and concentrated to 100 times or 1,000 times by a solid phase extraction method. As the test results, it was found that GA level in actual river water varied widely from less than the determination limit of 23 [1/L] to 1,100 [1/L] by quantitative comparison, and the value was also equivalent to more than 50 times the level of tap water. The GA level of household wastewater was not so high, but the levels of treated water from wastewater treatment plant (WTP) were from 220 [1/L] to 3,200 [1/L]. Raw sewage of some WTP shows high level genotoxicity. A part of genotoxicity substances, for example 50%, could be removed by conventional wastewater treatment, but it was not enough to reduce the water environmental load of genotoxicity.
Zinelis, Spiros; Al Jabbari, Youssef S
2018-05-01
This study was conducted to evaluate the failure mechanism of clinically failed Hedstrom (H)-files. Discarded H-files (n=160) from #8 to #40 ISO sizes were collected from different dental clinics. Retrieved files were classified according to their macroscopic appearance and they were investigated under scanning electron microscopy (SEM) and X-ray micro-computed tomography (mXCT). Then the files were embedded in resin along their longitudinal axis and after metallographic grinding and polishing, studied under an incident light microscope. The macroscopic evaluation showed that small ISO sizes (#08-#15) failed by extensive plastic deformation, while larger sizes (≥#20) tended to fracture. Light microscopy and mXCT results coincided showing that unused and plastically deformed files were free of internal defects, while fractured files demonstrate the presence of intense cracking in the flute region. SEM analysis revealed the presence of striations attributed to the fatigue mechanism. Secondary cracks were also identified by optical microscopy and their distribution was correlated to fatigue under bending loading. Experimental results demonstrated that while overloading of cutting instruments is the predominating failure mechanism of small file sizes (#08-#15), fatigue should be considered the fracture mechanism for larger sizes (≥#20).
Affatato, Saverio; Zanini, Filippo; Carmignato, Simone
2017-01-01
Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. PMID:28772616
Frederick C. Meinzer; David R. Woodruff; Danielle E. Marias; Duncan D. Smith; Katherine A. McCulloh; Ava R. Howard; Alicia L. Magedman; Josep Penuelas
2016-01-01
The concept of iso- vs. anisohydry has been used to describe the stringency of stomatal regulation of plant water potential (Ï). However, metrics that accurately and consistently quantify speciesâ operating ranges along a continuum of iso- to anisohydry have been elusive. Additionally, most approaches to quantifying iso/anisohydry require labour-intensive measurements...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Standardization (ISO) 1, rue de Varembé, Case postale 56, CH-1211 Geneva 20, Switzerland (Internet: http://www.iso.org): (1) International Standard ISO 8217 Third edition 2005-11-01, Petroleum products—Fuels (class F)—Specifications of marine fuels (“ISO 8217”), incorporation by reference approved for § 162.050-20. (2...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Standardization (ISO) 1, rue de Varembé, Case postale 56, CH-1211 Geneva 20, Switzerland (Internet: http://www.iso.org): (1) International Standard ISO 8217 Third edition 2005-11-01, Petroleum products—Fuels (class F)—Specifications of marine fuels (“ISO 8217”), incorporation by reference approved for § 162.050-20. (2...
Deflection load characteristics of laser-welded orthodontic wires.
Watanabe, Etsuko; Stigall, Garrett; Elshahawy, Waleed; Watanabe, Ikuya
2012-07-01
To compare the deflection load characteristics of homogeneous and heterogeneous joints made by laser welding using various types of orthodontic wires. Four kinds of straight orthodontic rectangular wires (0.017 inch × 0.025 inch) were used: stainless-steel (SS), cobalt-chromium-nickel (Co-Cr-Ni), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (12 mm long each) were made by Nd:YAG laser welding. Two types of welding methods were used: two-point welding and four-point welding. Nonwelded wires were also used as a control. Deflection load (N) was measured by conducting the three-point bending test. The data (n = 5) were statistically analyzed using analysis of variance/Tukey test (P < .05). The deflection loads for control wires measured were as follows: SS: 21.7 ± 0.8 N; Co-Cr-Ni: 20.0 ± 0.3 N; β-Ti: 13.9 ± 1.3 N; and Ni-Ti: 6.6 ± 0.4 N. All of the homogeneously welded specimens showed lower deflection loads compared to corresponding control wires and exhibited higher deflection loads compared to heterogeneously welded combinations. For homogeneous combinations, Co-Cr-Ni/Co-Cr-Ni showed a significantly (P < .05) higher deflection load than those of the remaining homogeneously welded groups. In heterogeneous combinations, SS/Co-Cr-Ni and β-Ti/Ni-Ti showed higher deflection loads than those of the remaining heterogeneously welded combinations (significantly higher for SS/Co-Cr-Ni). Significance (P < .01) was shown for the interaction between the two factors (materials combination and welding method). However, no significant difference in deflection load was found between four-point and two-point welding in each homogeneous or heterogeneous combination. Heterogeneously laser-welded SS/Co-Cr-Ni and β-Ti/Ni-Ti wires provide a deflection load that is comparable to that of homogeneously welded orthodontic wires.
Mühlemann, Sven; Truninger, Thomas C; Stawarczyk, Bogna; Hämmerle, Christoph H F; Sailer, Irena
2014-01-01
To test the fracture load and fracture patterns of zirconia abutments restored with all-ceramic crowns after fatigue loading, exhibiting internal and external implant-abutment connections as compared to restored and internally fixed titanium abutments. A master abutment was used for the customization of 5 groups of zirconia abutments to a similar shape (test). The groups differed according to their implant-abutment connections: one-piece internal connection (BL; Straumann Bonelevel), two-piece internal connection (RS; Nobel Biocare ReplaceSelect), external connection (B; Branemark MkIII), two-piece internal connection (SP, Straumann StandardPlus) and one-piece internal connection (A; Astra Tech AB OsseoSpeed). Titanium abutments with internal implant-abutment connection (T; Straumann Bonelevel) served as control group. In each group, 12 abutments were fabricated, mounted to the respective implants and restored with glass-ceramic crowns. All samples were embedded in acrylic holders (ISO-Norm 14801). After aging by means of thermocycling in a chewing simulator, static load was applied until failure (ISO-Norm 14801). Fracture load was analyzed by calculating the bending moments. Values of all groups were compared with one-way ANOVA followed by Scheffé post hoc test (P-value<0.05). Failure mode was analyzed descriptively. The mean bending moments were 464.9 ± 106.6 N cm (BL), 581.8 ± 172.8 N cm (RS), 556.7 ± 128.4 N cm (B), 605.4 ± 54.7 N cm (SP), 216.4 ± 90.0 N cm (A) and 1042.0 ± 86.8 N cm (T). No difference of mean bending moments was found between groups BL, RS, B and SP. Test group A exhibited significantly lower mean bending moment than the other test groups. Control group T had significantly higher bending moments than all test groups. Failure due to fracture of the abutment and/or crown occurred in the test groups. In groups BL and A, fractures were located in the internal part of the connection, whereas in groups RS and SP, a partial deformation of the implant components occurred and cracks and fractures of the zirconia abutment were detected. The differently connected zirconia abutments exhibited similar bending moments with the exception of one group. Hence, the type of connection only had a minor effect on the stability of restored zirconia abutments. In general, restored titanium abutments exhibited the highest bending moments. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
On the long-term stability of calibration standards in different matrices.
Kandić, A; Vukanac, I; Djurašević, M; Novković, D; Šešlak, B; Milošević, Z
2012-09-01
In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mert, Handan; Yılmaz, Hikmet; Irak, Kıvanç; Yıldırım, Serkan; Mert, Nihat
2018-01-01
Abstract This study aims to investigate the protective effects of kefir against myocardial infarction induced by isoproterenol (ISO). The rats were randomly divided into 4 groups, each group consisting of 8 rats. The control group, the kefir group (5 mL/kg/d kefir administered to rats as intra-gastric gavage for 60 d), the ISO group (100 mg/kg ISO was administered to rats, s.c. on 61. and 62. d), and kefir+ISO group (5 mL/kg/d kefir was administered to rats intra gastric gavage for 60 days prior to ISO, 100 mg/kg in two doses on day 61 and 62). 12 h after the last ISO dose, all rats were decapitated and their blood samples were collected. Cardiac tissue was reserved for histopathological examination. creatine kinase (CK), alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), triglycerides, total cholesterol,very low density lipoprotein (VLDL), low density lipoprotein (LDL), high density lipoprotein (HDL) and glucose were measured by autoanalyzer, whole blood malondialdehyde (MDA), glutathione (GSH) and plasma advanced oxidation protein products (AOPP) levels were measured spectrophotometrically. It was determined that in the group of kefir+ISO, the levels of AST (p<0.001), CK (p<0.001), LDH (p<0.001), MDA (p<0.001) and AOPP (p<0.001) were decreased, while the GSH (p<0.05) increased, compared to ISO group. There were no significant changes in lipid profile and glucose levels between these two groups. In conclusion, by examining cardiac enzymes and histopathological changes in cardiac tissue, it can be concluded that the administration of kefir in myocardial infarction induced by ISO can protect the heart with its antioxidant characteristic and minimize the toxic damage created by ISO. PMID:29805276
Mert, Handan; Yılmaz, Hikmet; Irak, Kıvanç; Yıldırım, Serkan; Mert, Nihat
2018-04-01
This study aims to investigate the protective effects of kefir against myocardial infarction induced by isoproterenol (ISO). The rats were randomly divided into 4 groups, each group consisting of 8 rats. The control group, the kefir group (5 mL/kg/d kefir administered to rats as intra-gastric gavage for 60 d), the ISO group (100 mg/kg ISO was administered to rats, s.c. on 61. and 62. d), and kefir+ISO group (5 mL/kg/d kefir was administered to rats intra gastric gavage for 60 days prior to ISO, 100 mg/kg in two doses on day 61 and 62). 12 h after the last ISO dose, all rats were decapitated and their blood samples were collected. Cardiac tissue was reserved for histopathological examination. creatine kinase (CK), alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), triglycerides, total cholesterol,very low density lipoprotein (VLDL), low density lipoprotein (LDL), high density lipoprotein (HDL) and glucose were measured by autoanalyzer, whole blood malondialdehyde (MDA), glutathione (GSH) and plasma advanced oxidation protein products (AOPP) levels were measured spectrophotometrically. It was determined that in the group of kefir+ISO, the levels of AST ( p <0.001), CK ( p <0.001), LDH ( p <0.001), MDA ( p <0.001) and AOPP ( p <0.001) were decreased, while the GSH ( p <0.05) increased, compared to ISO group. There were no significant changes in lipid profile and glucose levels between these two groups. In conclusion, by examining cardiac enzymes and histopathological changes in cardiac tissue, it can be concluded that the administration of kefir in myocardial infarction induced by ISO can protect the heart with its antioxidant characteristic and minimize the toxic damage created by ISO.
Bainbridge, Melissa L.; Cersosimo, Laura M.; Wright, André-Denis G.; Kraft, Jana
2016-01-01
Dairy products contain bioactive fatty acids (FA) and are a unique dietary source of an emerging class of bioactive FA, branched-chain fatty acids (BCFA). The objective of this study was to compare the content and profile of bioactive FA in milk, with emphasis on BCFA, among Holstein (HO), Jersey (JE), and first generation HO x JE crossbreeds (CB) across a lactation to better understand the impact of these factors on FA of interest to human health. Twenty-two primiparous cows (n = 7 HO, n = 7 CB, n = 8 JE) were followed across a lactation. All cows were fed a consistent total mixed ration (TMR) at a 70:30 forage to concentrate ratio. Time points were defined as 5 days in milk (DIM), 95 DIM, 185 DIM, and 275 DIM. HO and CB had a higher content of n-3 FA at 5 DIM than JE and a lower n-6:n-3 ratio. Time point had an effect on the n-6:n-3 ratio, with the lowest value observed at 5 DIM and the highest at 185 DIM. The content of vaccenic acid was highest at 5 DIM, yet rumenic acid was unaffected by time point or breed. Total odd and BCFA (OBCFA) were higher in JE than HO and CB at 185 and 275 DIM. Breed affected the content of individual BCFA. The content of iso-14:0 and iso-16:0 in milk was higher in JE than HO and CB from 95 to 275 DIM. Total OBCFA were affected by time point, with the highest content in milk at 275 DIM. In conclusion, HO and CB exhibited a higher content of several bioactive FA in milk than JE. Across a lactation the greatest content of bioactive FA in milk occurred at 5 DIM and OBCFA were highest at 275 DIM. PMID:26930646
Bainbridge, Melissa L; Cersosimo, Laura M; Wright, André-Denis G; Kraft, Jana
2016-01-01
Dairy products contain bioactive fatty acids (FA) and are a unique dietary source of an emerging class of bioactive FA, branched-chain fatty acids (BCFA). The objective of this study was to compare the content and profile of bioactive FA in milk, with emphasis on BCFA, among Holstein (HO), Jersey (JE), and first generation HO x JE crossbreeds (CB) across a lactation to better understand the impact of these factors on FA of interest to human health. Twenty-two primiparous cows (n = 7 HO, n = 7 CB, n = 8 JE) were followed across a lactation. All cows were fed a consistent total mixed ration (TMR) at a 70:30 forage to concentrate ratio. Time points were defined as 5 days in milk (DIM), 95 DIM, 185 DIM, and 275 DIM. HO and CB had a higher content of n-3 FA at 5 DIM than JE and a lower n-6:n-3 ratio. Time point had an effect on the n-6:n-3 ratio, with the lowest value observed at 5 DIM and the highest at 185 DIM. The content of vaccenic acid was highest at 5 DIM, yet rumenic acid was unaffected by time point or breed. Total odd and BCFA (OBCFA) were higher in JE than HO and CB at 185 and 275 DIM. Breed affected the content of individual BCFA. The content of iso-14:0 and iso-16:0 in milk was higher in JE than HO and CB from 95 to 275 DIM. Total OBCFA were affected by time point, with the highest content in milk at 275 DIM. In conclusion, HO and CB exhibited a higher content of several bioactive FA in milk than JE. Across a lactation the greatest content of bioactive FA in milk occurred at 5 DIM and OBCFA were highest at 275 DIM.
Albert, Devon L; Beeman, Stephanie M; Kemper, Andrew R
2018-02-28
The objective of this research was to compare the occupant kinematics of the Hybrid III (HIII), THOR-M, and postmortem human surrogates (PMHS) during full-scale frontal sled tests under 3 safety restraint conditions: knee bolster (KB), knee bolster and steering wheel airbag (KB/SWAB), and knee bolster airbag and steering wheel airbag (KBAB/SWAB). A total of 20 frontal sled tests were performed with at least 2 tests performed per restraint condition per surrogate. The tests were designed to match the 2012 Toyota Camry New Car Assessment Program (NCAP) full-scale crash test. Rigid polyurethane foam surrogates with compressive strength ratings of 65 and 19 psi were used to simulate the KB and KBAB, respectively. The excursions of the head, shoulders, hips, knees, and ankles were collected using motion capture. Linear acceleration and angular velocity data were also collected from the head, thorax, and pelvis of each surrogate. Time histories were compared between surrogates and restraint conditions using ISO/TS 18571. All surrogates showed some degree of sensitivity to changes in restraint condition. For example, the use of a KBAB decreased the pelvis accelerations and the forward excursions of the knees and hips for all surrogates. However, these trends were not observed for the thorax, shoulders, and head, which showed more sensitivity to the presence of a SWAB. The average scores computed using ISO/TS 18571 for the HIII/PMHS and THOR-M/PMHS comparisons were 0.527 and 0.518, respectively. The HIII had slightly higher scores than the THOR-M for the excursions (HIII average = 0.574; THOR average = 0.520). However, the THOR-M had slightly higher scores for the accelerations and angular rates (HIII average = 0.471; THOR average = 0.516). The data from the current study showed that both KBABs and SWABs affected the kinematics of all surrogates during frontal sled tests. The results of the objective rating analysis indicated that the HIII and THOR-M had comparable overall biofidelity scores. The THOR-M slightly outperformed the HIII for the acceleration and angular velocity data. However, the HIII scored slightly better than the THOR-M for the excursion data. The most notable difference in biofidelity was for the knee excursions, where the HIII had a much higher average ISO score. Only the biofidelity of the HIII and THOR-M with regard to occupant kinematics was evaluated in this study; therefore, future work will evaluate the biofidelity of the ATDs in terms of lower extremity loading, thoracic response, and neck loading.
Combination Space Station Handrail Clamp and Pointing Device
NASA Technical Reports Server (NTRS)
Hughes, Stephen J. (Inventor)
1999-01-01
A device for attaching an experiment carrier to a space station handrail is provided. The device has two major components, a clamping mechanism for attachment to a space station handrail, and a pointing carrier on which an experiment package can be mounted and oriented. The handrail clamp uses an overcenter mechanism and the carrier mechanism uses an adjustable preload ball and socket for carrier positioning. The handrail clamp uses a stack of disk springs to provide a spring loaded button. This configuration provides consistent clamping force over a range of possible handrail thicknesses. Three load points are incorporated in the clamping mechanism thereby spreading the clamping load onto three separate points on the handrail. A four bar linkage is used to provide for a single actuation lever for all three load points. For additional safety, a secondary lock consisting of a capture plate and push lock keeps the clamp attached to the handrail in the event of main clamp failure. For the carrier positioning mechanism, a ball in a spring loaded socket uses friction to provide locking torque; however. the ball and socket are torque limited so that the ball ran slip under kick loads (125 pounds or greater). A lead screw attached to disk spring stacks is used to provide an adjustable spring force on the socket. A locking knob is attached to the lead screw to allow for hand manipulation of the lead screw.
Kim, Yusung; Tomé, Wolfgang A.
2010-01-01
Summary Voxel based iso-Tumor Control Probability (TCP) maps and iso-Complication maps are proposed as a plan-review tool especially for functional image-guided intensity-modulated radiotherapy (IMRT) strategies such as selective boosting (dose painting) and conformal avoidance IMRT. The maps employ voxel-based phenomenological biological dose-response models for target volumes and normal organs. Two IMRT strategies for prostate cancer, namely conventional uniform IMRT delivering an EUD = 84 Gy (equivalent uniform dose) to the entire PTV and selective boosting delivering an EUD = 82 Gy to the entire PTV, are investigated, to illustrate the advantages of this approach over iso-dose maps. Conventional uniform IMRT did yield a more uniform isodose map to the entire PTV while selective boosting did result in a nonuniform isodose map. However, when employing voxel based iso-TCP maps selective boosting exhibited a more uniform tumor control probability map compared to what could be achieved using conventional uniform IMRT, which showed TCP cold spots in high-risk tumor subvolumes despite delivering a higher EUD to the entire PTV. Voxel based iso-Complication maps are presented for rectum and bladder, and their utilization for selective avoidance IMRT strategies are discussed. We believe as the need for functional image guided treatment planning grows, voxel based iso-TCP and iso-Complication maps will become an important tool to assess the integrity of such treatment plans. PMID:21151734
Dietary fats and F2-isoprostanes: A review of the clinical evidence.
Da Silva, Marine S; Bilodeau, Jean-François; Julien, Pierre; Rudkowska, Iwona
2017-12-12
Evidence supports that a high dietary fat intake increases oxidative stress and the risk of diet-induced metabolic disorders such as obesity, diabetes and cardiovascular diseases. F 2 -isoprostanes (F 2 -isoP) are formed by the non-enzymatic oxidation of arachidonic acid and are widely used as reliable biomarkers of oxidative stress in clinical studies. Dietary fats may influence F 2 -isoP levels, as they (1) are metabolic substrates for their formation, (2) modify the lipid composition of tissues, and (3) affect the plasma lipoprotein concentrations which are involved in F 2 -isoP transport. This review examined the latest clinical evidence on how dietary fats can affect blood circulation and excretion of F 2 -isoP in individuals with healthy or deteriorated metabolic profiles. Clinical studies reported that saturated or monounsaturated fat-rich diets did not affect F 2 -isoP levels in adults with healthy or deteriorated metabolic profiles. Though, ω-3 polyunsaturated fatty acids decreased F 2 -isoP levels in numerous studies, whereas trans-fatty acids raised F 2 -isoP excretion. Yet, the reported heterogeneous results reveal important considerations, such as the health status of the participants, the biological fluids used to determine F 2 -isoP, the analytical methods employed and the specific F 2 -isoP isomers detected. Therefore, future clinical studies should be designed in order to consider these issues in the studies of the effects of fat intake on oxidative stress.
IsoWeb: A Bayesian Isotope Mixing Model for Diet Analysis of the Whole Food Web
Kadoya, Taku; Osada, Yutaka; Takimoto, Gaku
2012-01-01
Quantitative description of food webs provides fundamental information for the understanding of population, community, and ecosystem dynamics. Recently, stable isotope mixing models have been widely used to quantify dietary proportions of different food resources to a focal consumer. Here we propose a novel mixing model (IsoWeb) that estimates diet proportions of all consumers in a food web based on stable isotope information. IsoWeb requires a topological description of a food web, and stable isotope signatures of all consumers and resources in the web. A merit of IsoWeb is that it takes into account variation in trophic enrichment factors among different consumer-resource links. Sensitivity analysis using realistic hypothetical food webs suggests that IsoWeb is applicable to a wide variety of food webs differing in the number of species, connectance, sample size, and data variability. Sensitivity analysis based on real topological webs showed that IsoWeb can allow for a certain level of topological uncertainty in target food webs, including erroneously assuming false links, omission of existent links and species, and trophic aggregation into trophospecies. Moreover, using an illustrative application to a real food web, we demonstrated that IsoWeb can compare the plausibility of different candidate topologies for a focal web. These results suggest that IsoWeb provides a powerful tool to analyze food-web structure from stable isotope data. We provide R and BUGS codes to aid efficient applications of IsoWeb. PMID:22848427
NASA Astrophysics Data System (ADS)
Wang, H.; Chen, K.; Wu, Z.; Guan, X.
2017-12-01
In recent years, with the prominent of water environment problem and the relative increase of point source pollution governance, especially the agricultural non-point source pollution problem caused by the extensive use of fertilizers and pesticides has become increasingly aroused people's concern and attention. In order to reveal the quantitative relationship between agriculture water and fertilizer and non-point source pollution, on the basis of elm field experiment and combined with agricultural drainage irrigation model, the agricultural irrigation water and the relationship between fertilizer and fertilization scheme and non-point source pollution were analyzed and calculated by field emission intensity index. The results show that the variation of displacement varies greatly under different irrigation conditions. When the irrigation water increased from 22cm to 42cm, the irrigation water increased by 20 cm while the field displacement increased by 11.92 cm, about 66.22% of the added value of irrigation water. Then the irrigation water increased from 42 to 68, irrigation water increased 26 cm, and the field displacement increased by 22.48 cm, accounting for 86.46% of irrigation water. So there is an "inflection point" between the irrigation water amount and field displacement amount. The load intensity increases with the increase of irrigation water and shows a significant power correlation. Under the different irrigation condition, the increase amplitude of load intensity with the increase of irrigation water is different. When the irrigation water is smaller, the load intensity increase relatively less, and when the irrigation water increased to about 42 cm, the load intensity will increase considerably. In addition, there was a positive correlation between the fertilization and load intensity. The load intensity had obvious difference in different fertilization modes even with same fertilization level, in which the fertilizer field unit load intensity increased the most in July. The results provide some basis for the field control and management of agricultural non-point source pollution.
Apportioning riverine DIN load to export coefficients of land uses in an urbanized watershed.
Shih, Yu-Ting; Lee, Tsung-Yu; Huang, Jr-Chuan; Kao, Shuh-Ji; Chang
2016-08-01
The apportionment of riverine dissolved inorganic nitrogen (DIN) load to individual land use on a watershed scale demands the support of accurate DIN load estimation and differentiation of point and non-point sources, but both of them are rarely quantitatively determined in small montane watersheds. We introduced the Danshui River watershed of Taiwan, a mountainous urbanized watershed, to determine the export coefficients via a reverse Monte Carlo approach from riverine DIN load. The results showed that the dynamics of N fluctuation determines the load estimation method and sampling frequency. On a monthly sampling frequency basis, the average load estimation of the methods (GM, FW, and LI) outperformed that of individual method. Export coefficient analysis showed that the forest DIN yield of 521.5kg-Nkm(-2)yr(-1) was ~2.7-fold higher than the global riverine DIN yield (mainly from temperate large rivers with various land use compositions). Such a high yield was attributable to high rainfall and atmospheric N deposition. The export coefficient of agriculture was disproportionately larger than forest suggesting that a small replacement of forest to agriculture could lead to considerable change of DIN load. The analysis of differentiation between point and non-point sources showed that the untreated wastewater (non-point source), accounting for ~93% of the total human-associated wastewater, resulted in a high export coefficient of urban. The inclusion of the treated and untreated wastewater completes the N budget of wastewater. The export coefficient approach serves well to assess the riverine DIN load and to improve the understanding of N cascade. Copyright © 2016 Elsevier B.V. All rights reserved.
Composite-Material Point-Stress Analysis
NASA Technical Reports Server (NTRS)
Spears, F., S.
1982-01-01
PSANAL computes composite-laminate elastic and thermal properties and allowable load levels for any combination of applied membrane and bending loads occurring at a point. Basic linear orthotropic stress/ strain relationships and standard composite-laminate theory formulas are utilized.
2008-07-01
cycle Evolution of a system, product, service, project or other human-made entity from conception through retirement [ ISO 12207 ]. Logical line of...012 [ ISO 1995] International Organization for Standardization. ISO /IEC 12207 :1995—Information technology— Software life cycle processes. http...definitions, authors were asked to use or align with already existing standards such as those available through ISO and IEEE when possible. Literature
Screw-Thread Standards for Federal Services, 1957. Handbook H28 (1957), Part 3
1957-09-01
MOUNTING THREADS PHOTOGRAPHIC EQUIPMENT THREADS ISO METRIC THREADS; MISCELLANEOUS THREADS CLASS 5 INTERFERENCE-FIT THREADS, TRIAL STANDARD WRENCH...Bibliography on measurement of pitch diameter by means of wires 60 Appendix 14. Metric screw-thread standards 61 1. ISO thread profiles...61 2. Standard series for ISO metric threads 62 3. Designations for ISO metric threads 62 Tables Page Table XII. 1.—Basic
Cyber-Forensic Research Experimentation and Test Environment (CREATE)
2002-10-01
group. The existence of this forum would tend to support the ISO 17025 provision mentioned earlier. It would also support...criteria encompass the requirements of ISO / IEC Guide 25, and the relevant requirements of ISO 9002 (ANSI/ASQC Q92-1987) as suppliers of calibration or...there are no current standards, they have decided to abide by the International Organization for Standards ( ISO ) 17025,25 which has a provision for
Effectiveness of the Department of Defense Information Assurance Accreditation Process
2013-03-01
meeting the requirements of ISO 27001, Information Security Management System. ISO 27002 provides “security techniques” or best practices that can be...efforts to the next level and implement a recognized standard such as the International Organization for Standards ( ISO ) 27000 Series of standards...implemented by an organization as part of their certification effort.15 Most likely, the main motivation a company would have for achieving an ISO
A debranching enzyme IsoM of Corallococcus sp. strain EGB with potential in starch processing.
Li, Zhoukun; Ji, Kai; Zhou, Jie; Ye, Xianfeng; Wang, Ting; Luo, Xue; Huang, Yan; Cao, Hui; Cui, Zhongli; Kong, Yi
2017-12-01
Interest in use of resistant starch and maltooligosaccharides as functional foods and biopreservatives has grown in recent years. In this research, a novel debranching enzyme IsoM from Corallococcus sp. strain EGB was identified and expressed in P. pastoris GS115. Sequence alignments showed that IsoM was typical isoamylase with the specific activity up to 70,600U/mg, which belongs to glycoside hydrolase family 13 (GH 13). Enzymatic reaction pattern demonstrated that IsoM has high debranching efficiency against α-1,6-glycosidic bond of branched starch, and exhibited no activity towards α-1,4-glycosidic bond. The potential application of IsoM in starch processing was determined. IsoM was a potential candidate for the production of RS (70.9%) from raw starch, which was comparable with the commercial pullulanase (Promozyme ® D2). IsoM also improved the maltohexaose yield in combination with maltohexaose-producing α-amylase AmyM (KM114206), the maltohexaose yield was improved by 63.3% compared with 21.9% improvement of Promozyme ® D2. The results of RS production and combination with other amylases suggesting that IsoM is a potential candidate for the efficient conversion of starch. Copyright © 2017. Published by Elsevier B.V.
Mezher, T; Ramadan, H
1998-01-01
Many Saudi companies, in their journey to improve quality, efficiency and competitiveness, are pursuing and obtaining the ISO 9000 certificate. Many studies have evaluated how to implement ISO 9000 in different sectors, but none have analyzed the effectiveness of ISO 9000 certification (costs and benefits) on improving the overall quality and on meeting expectations. This study addressed these issues by investigating manufacturing organizations in Saudi Arabia that have the ISO 9000 certification. A survey questionnaire was distributed to firms throughout the kingdom. Thirty-two firms participated in the study. Results indicate that increased consistency of operations, improved service, and product quality are among the top motivators for pursuing the ISO certificate. The benefits most often experienced were improved awareness of procedural problems, better management control, keeping existing customers, increased customer satisfaction, and improved customer service. Difficulties experienced during the certification process involved time and cost, but these were not considered to be major problems. A high volume of paperwork was the main problem experienced following initial certification. Respondents in general said that the ISO 9000 certification met their expectations and that their level of satisfaction regarding the impact of ISO 9000 was high. Most recommended that other organizations pursue the certificate.
From ISO 9001:2008 to ISO 9001:2015: Significant changes and their impacts to aspiring organizations
NASA Astrophysics Data System (ADS)
Sari, Y.; Wibisono, E.; Wahyudi, R. D.; Lio, Y.
2017-11-01
ISO 9001:2015 is the latest version of ISO Quality Management System standard that has been updated recently from ISO 9001:2008. It is necessary for all organizations that have implemented and been certified with ISO 9001:2008 to prepare the transition and upgrade their Quality Management System because the certification will expire by September 2018. This paper attempts to provide knowledge on the significant changes from ISO 9001:2008 to ISO 9001:2015, what new requirements are added, and how they would impact the organizations. An exploratory and applied research was chosen as the research approach and aimed to explore what transition designs are needed to anticipate the changes as well as their impacts. The research applied a methodology of Plan-Do-Check-Action (PDCA) cycle into four organizations and their results were compared and discussed to explain the transition designs. Some qualitative methods such as observation and interview were used to collect the data. By addressing the new requirements, three transition designs that should be prepared are: (i) identifying needs from interested parties, (ii) analyzing internal and external factors of the organizations to formulate relevant strategies and quality objectives, and (iii) registering risks associated to business processes as well as organizational strategies.
Topal, G; Donmez, A; Doğan, B S Uydes; Kucur, M; Cengiz, D Taspinar; Berkoz, F B; Erdogan, N
2011-04-01
The aim of the study was to investigate serum levels of asymmetric dimethylarginine (ADMA), tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6) and plasma levels of 8-iso-prostaglandin F(2α) (8-iso-PGF(2α)) in patients with fibromyalgia. Twenty-seven patients with fibromyalgia and twenty healthy controls were enrolled in this study. ADMA, TNF-α, IL-6 and 8-iso-PGF(2α) levels were measured by enzyme-linked immunosorbent assay (ELISA). Serum levels of ADMA and TNF-α and plasma levels 8-iso-PGF(2α) were significantly increased in patients with fibromyalgia compared to controls. However, no significant difference was observed in IL-6 levels between the two groups. ADMA concentrations were positively correlated with TNF-α and 8-iso-PGF(2α) levels in patients with fibromyalgia. This is the first study reporting that ADMA levels are significantly elevated in patients with fibromyalgia in association with increased 8-iso-PGF(2α) and TNF-α concentrations. Thereby, ADMA could be suggested as a reliable marker of endothelial dysfunction in patients with fibromyalgia. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
A generalized force-modified potential energy surface (G-FMPES) for mechanochemical simulations
Subramanian, Gopinath; Mathew, Nithin; Leiding, Jeffery A.
2015-10-05
We describe the modifications that a spatially varying external load produces on a Born-Oppenheimer potential energy surface (PES) by calculating static quantities of interest. The effects of the external loads are exemplified using electronic structure calculations (at the HF/6-31G** level) of two different molecules: ethane and hexahydro-1,3,5-trinitro-s-triazine (RDX). The calculated transition states and The Hessian matrices of stationary points show that spatially varying external loads shift the stationary points and modify the curvature of the PES, thereby affecting the harmonic transition rates by altering both the energy barrier as well as the prefactor. The harmonic spectra of both molecules aremore » blue-shifted with increasing compressive “pressure.” Some stationary points on the RDX-PES disappear under application of the external load, indicating the merging of an energy minimum with a saddle point.« less
Hempstead, Melissa N; Waas, Joseph R; Stewart, Mairi; Dowling, Suzanne K; Cave, Vanessa M; Lowe, Gemma L; Sutherland, Mhairi A
2018-04-01
Cautery disbudding of goat kids is painful, but may be alleviated with pain mitigation. We therefore evaluated the effect of administering general anesthesia (isoflurane) or a nonsteroidal anti-inflammatory drug (meloxicam) on goat kid behavior and physiology following cautery disbudding. Trial 1 (n = 12/treatment) evaluated behavioral responses in 72 female Saanen dairy goat kids (mean ± standard error of the mean; 3.9 ± 0.15 d old) and trial 2 (n = 10/treatment) evaluated physiological responses in 60 female Saanen dairy goat kids (4.3 ± 0.14 d old). Goat kids were randomly assigned to 1 of 6 treatment groups that were either (1) sham-handled only (simulated disbudding; SHAM) or disbudded with (2) no pain relief (CAUT), (3) isoflurane gas (ISO), (4) isoflurane and s.c. meloxicam combined (ISO+MEL), (5) meloxicam s.c. (0.5 mg/kg of body weight; I-MEL), or (6) oral meloxicam (0.2 mg/kg of body weight; O-MEL). Head shaking, head scratching, self-grooming, feeding, and body shaking were continuously video recorded for 24 h pre- and post-treatment. Lying behavior was recorded continuously for 24 h pre- and post-treatment using accelerometers. Plasma cortisol, glucose, and lactate concentrations were measured from blood samples collected immediately before treatment (baseline) and at 15, 60, and 120 min post-treatment. Body temperature was measured immediately after blood sampling at all blood sampling time points. Head shaking and body shaking frequencies were 50% higher in CAUT than SHAM kids 5 min post-treatment; ISO+MEL and ISO kids performed 25% less body shakes than CAUT kids. Head scratching durations 1 h post-treatment were higher in CAUT than SHAM kids, whereas O-MEL were similar to SHAM kids from 2 h post-treatment. Self-grooming, feeding, and lying did not differ between groups. Cortisol concentrations were higher in CAUT than SHAM kids (156.4 ± 26.41 and 104.1 ± 26.41 nmol/L, respectively), whereas ISO+MEL and ISO kids (88.3 ± 26.41 and 113.2 ± 26.41 nmol/L, respectively) had lower cortisol concentrations than CAUT kids over the 2-h sampling period. Moreover, O-MEL and I-MEL kids (163.0 ± 26.41 and 130.9 ± 26.41 nmol/L, respectively) had similar cortisol concentrations to CAUT kids. We found no evidence that plasma glucose and lactate concentrations or body temperature were affected by treatment. The administration of isoflurane, with or without meloxicam, appeared to reduce pain associated with cautery disbudding. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Global Impact Estimation of ISO 50001 Energy Management System for Industrial and Service Sectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aghajanzadeh, Arian; Therkelsen, Peter L.; Rao, Prakash
A methodology has been developed to determine the impacts of ISO 50001 Energy Management System (EnMS) at a region or country level. The impacts of ISO 50001 EnMS include energy, CO2 emissions, and cost savings. This internationally recognized and transparent methodology has been embodied in a user friendly Microsoft Excel® based tool called ISO 50001 Impact Estimator Tool (IET 50001). However, the tool inputs are critical in order to get accurate and defensible results. This report is intended to document the data sources used and assumptions made to calculate the global impact of ISO 50001 EnMS.
OntoCR: A CEN/ISO-13606 clinical repository based on ontologies.
Lozano-Rubí, Raimundo; Muñoz Carrero, Adolfo; Serrano Balazote, Pablo; Pastor, Xavier
2016-04-01
To design a new semantically interoperable clinical repository, based on ontologies, conforming to CEN/ISO 13606 standard. The approach followed is to extend OntoCRF, a framework for the development of clinical repositories based on ontologies. The meta-model of OntoCRF has been extended by incorporating an OWL model integrating CEN/ISO 13606, ISO 21090 and SNOMED CT structure. This approach has demonstrated a complete evaluation cycle involving the creation of the meta-model in OWL format, the creation of a simple test application, and the communication of standardized extracts to another organization. Using a CEN/ISO 13606 based system, an indefinite number of archetypes can be merged (and reused) to build new applications. Our approach, based on the use of ontologies, maintains data storage independent of content specification. With this approach, relational technology can be used for storage, maintaining extensibility capabilities. The present work demonstrates that it is possible to build a native CEN/ISO 13606 repository for the storage of clinical data. We have demonstrated semantic interoperability of clinical information using CEN/ISO 13606 extracts. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benko, Heather
In carrying out its responsibilities on behalf of the United States, ANSI provides comprehensive, administrative support and expertise on international protocols and procedures to: (1) the U.S. Technical Advisory Group (TAG) to the International Organization for Standardization’s (ISO) Technical Committee (TC) 229 Nanotechnologies, and (2) the corresponding U.S. TAG Working Groups tasked with formulating U.S. positions on topics relevant to nanotechnology standardization. Additionally, secretariat and procedural support is provided for the ISO/TC 229 WG 3 on health, safety and environment, for which the United States was assigned leadership by the participating national body members of ISO/TC 229. As the officialmore » entity that serves as the U.S. representative to ISO, ANSI provides not only expert coordination of U.S. positions and representation at ISO but also strategic direction, advice and procedural expertise to facilitate navigation of international issues to promote U.S. positions for incorporation into the ISO/TC 229 program of work necessary to support U.S. objectives.« less
An alternative method for centrifugal compressor loading factor modelling
NASA Astrophysics Data System (ADS)
Galerkin, Y.; Drozdov, A.; Rekstin, A.; Soldatova, K.
2017-08-01
The loading factor at design point is calculated by one or other empirical formula in classical design methods. Performance modelling as a whole is out of consideration. Test data of compressor stages demonstrates that loading factor versus flow coefficient at the impeller exit has a linear character independent of compressibility. Known Universal Modelling Method exploits this fact. Two points define the function - loading factor at design point and at zero flow rate. The proper formulae include empirical coefficients. A good modelling result is possible if the choice of coefficients is based on experience and close analogs. Earlier Y. Galerkin and K. Soldatova had proposed to define loading factor performance by the angle of its inclination to the ordinate axis and by the loading factor at zero flow rate. Simple and definite equations with four geometry parameters were proposed for loading factor performance calculated for inviscid flow. The authors of this publication have studied the test performance of thirteen stages of different types. The equations are proposed with universal empirical coefficients. The calculation error lies in the range of plus to minus 1,5%. The alternative model of a loading factor performance modelling is included in new versions of the Universal Modelling Method.
Lin, Chun-Li; Kuo, Wen-Chuan; Yu, Jin-Jie; Huang, Shao-Fu
2013-04-01
CAD/CAM ceramic restorative material is routinely bonded to tooth substrates using adhesive cement. This study investigates micro-crack growth and damage in the ceramic/dentin adhesive interface under fatigue shear testing monitored using the acoustic emission (AE) technique with optical coherence tomography (OCT). Ceramic/dentin adhesive samples were prepared to measure the shear bond strength (SBS) under static load. Fatigue shear testing was performed using a modified ISO14801 method. Loads in the fatigue tests were applied at 80%, 70%, and 60% of the SBS to monitor interface debonding. The AE technique was used to detect micro-crack signals in static and fatigue shear bond tests. The results showed that the average SBS value in the static tests was 10.61±2.23MPa (mean±standard deviation). The average number of fatigue cycles in which ceramic/dentin interface damage was detected in 80%, 70% and 60% of the SBS were 152, 1962 and 9646, respectively. The acoustic behavior varied according to the applied load level. Events were emitted during 60% and 70% fatigue tests. A good correlation was observed between crack location in OCT images and the number of AE signal hits. The AE technique and OCT images employed in this study could potentially be used as a pre-clinical assessment tool to determine the integrity of cemented load bearing restored ceramic material. Sustainable cyclic load stresses in ceramic/dentin-bonded specimens were substantially lower than the measured SBS. Predicted S-N curve showed that the maximum endured load was 4.18MPa passing 10(6) fatigue cyclic. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Euler Strut: A Mechanical Analogy for Dynamics in the Vicinity of a Critical Point
ERIC Educational Resources Information Center
Bobnar, Jaka; Susman, Katarina; Parsegian, V. Adrian; Rand, Peter R.; Cepic, Mojca; Podgornik, Rudolf
2011-01-01
An anchored elastic filament (Euler strut) under an external point load applied to its free end is a simple model for a second-order phase transition. In the static case, a load greater than the critical load causes a Euler buckling instability, leading to a change in the filament's shape. The analysis of filament dynamics with an external point…
The Infrared Space Observatory (ISO)
NASA Technical Reports Server (NTRS)
Helou, George; Kessler, Martin F.
1995-01-01
ISO, scheduled to launch in 1995, will carry into orbit the most sophisticated infrared observatory of the decade. Overviews of the mission, instrument payload and scientific program are given, along with a comparison of the strengths of ISO and SOFIA.
46 CFR 162.017-1 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Standardization (ISO), Case postal 56, CH-1211 Geneva 20, Switzerland: (1) ISO 15364, Ships and Marine Technology—Pressure/Vacuum Valves for Cargo Tanks, First Edition (Sep. 1, 2000) (“ISO 15364”), 162.017-3; and (2...
46 CFR 162.017-1 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Standardization (ISO), Case postal 56, CH-1211 Geneva 20, Switzerland: (1) ISO 15364, Ships and Marine Technology—Pressure/Vacuum Valves for Cargo Tanks, First Edition (Sep. 1, 2000) (“ISO 15364”), 162.017-3; and (2...
Standards for Prognostics and Health Management (PHM) Techniques within Manufacturing Operations
2014-10-02
SOCIETY 2014 3 International Organization for Standardization (ISO), the Machinery Information Management Open Standards Alliance ( MIMOSA ), SAE...X X X X ISO TC 184/SC 4 X ISO TC 184/SC 5 X X ISO/IEC JTC 1/SC 7 X MIMOSA —— X SAE International AQPIC X SAE...THE PROGNOSTICS AND HEALTH MANAGEMENT SOCIETY 2014 4 HDBK is supported by the Machinery Information Management Open Standards Alliance ( MIMOSA ), a
An Agile Systems Engineering Process: The Missing Link?
2011-05-01
has a num- ber of standards available such as ISO 12207 , ISO 9001 and the Capability Maturity Model Integrated (CMMI®) [24,25,26]. The CMMI was a...addressing activities throughout the products lifecycle [24]. ISO 12207 “contains processes, activities and tasks that are to be applied during...the acquisition of a system that contains software” [26]. A limitation identified within ISO 12207 is that it does not specify details on how to
CrossTalk: The Journal of Defense Software Engineering. Volume 20, Number 3, March 2007
2007-03-01
Capability Maturity Model ® Integration (CMMI®). CMU Software Engineering Institute <www.sei.cmu.edu/cmmi>. 5. ISO /IEC 27001 :2005. Information Security...international standards bodies – International Organization for Standardi- zation ( ISO ) and International Electro- technical Commission (IEC) – are working on a...number of projects that affect soft- ware security: • The ISO Technical Management Board (TMB) performs strategic planning and coordination for ISO
Pardo, Scott; Simmons, David A
2016-09-01
The relationship between International Organization for Standardization (ISO) accuracy criteria and mean absolute relative difference (MARD), 2 methods for assessing the accuracy of blood glucose meters, is complex. While lower MARD values are generally better than higher MARD values, it is not possible to define a particular MARD value that ensures a blood glucose meter will satisfy the ISO accuracy criteria. The MARD value that ensures passing the ISO accuracy test can be described only as a probabilistic range. In this work, a Bayesian model is presented to represent the relationship between ISO accuracy criteria and MARD. Under the assumptions made in this work, there is nearly a 100% chance of satisfying ISO 15197:2013 accuracy requirements if the MARD value is between 3.25% and 5.25%. © 2016 Diabetes Technology Society.
ISO 9001 in a neonatal intensive care unit (NICU).
Vitner, Gad; Nadir, Erez; Feldman, Michael; Yurman, Shmuel
2011-01-01
The aim of this paper is to present the process for approving and certifying a neonatal intensive care unit to ISO 9001 standards. The process started with the department head's decision to improve services quality before deciding to achieve ISO 9001 certification. Department processes were mapped and quality management mechanisms were developed. Process control and performance measurements were defined and implemented to monitor the daily work. A service satisfaction review was conducted to get feedback from families. In total, 28 processes and related work instructions were defined. Process yields showed service improvements. Family satisfaction improved. The paper is based on preparing only one neonatal intensive care unit to the ISO 9001 standard. The case study should act as an incentive for hospital managers aiming to improve service quality based on the ISO 9001 standard. ISO 9001 is becoming a recommended tool to improve clinical service quality.
Endogenous Bioactive Jasmonate Is Composed of a Set of (+)-7-iso-JA-Amino Acid Conjugates1
Li, Suhua; Li, Yuwen; Chen, Juan; Yang, Mai; Tong, Jianhua; Xiao, Langtao; Nan, Fajun; Xie, Daoxin
2016-01-01
Jasmonates (JAs) regulate a wide range of plant defense and development processes. The bioactive JA is perceived by its receptor COI1 to trigger the degradation of JASMONATE ZIM-DOMAIN (JAZ) proteins and subsequently derepress the JAZ-repressed transcription factors for activation of expression of JA-responsive genes. So far, (+)-7-iso-JA-l-Ile has been the only identified endogenous bioactive JA molecule. Here, we designed coronafacic acid (CFA) conjugates with all the amino acids (CFA-AA) to mimic the JA amino acid conjugates, and revealed that (+)-7-iso-JA-Leu, (+)-7-iso-JA-Val, (+)-7-iso-JA-Met, and (+)-7-iso-JA-Ala are new endogenous bioactive JA molecules. Furthermore, our studies uncover the general characteristics for all the bioactive JA molecules, and provide a new strategy to synthetically generate novel active JA molecules. PMID:27756820
Peccei-Quinn symmetry for Dirac seesaw and leptogenesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gu, Pei-Hong
We extend the DFSZ invisible axion model to simultaneously explain small Dirac neutrino masses and cosmic matter-antimatter asymmetry. After the Peccei-Quinn and electroweak symmetry breaking, the effective Yukawa couplings of the Dirac neutrinos to the standard model Higgs scalar can be highly suppressed by the ratio of the vacuum expectation value of an iso-triplet Higgs scalar over the masses of some heavy gauge-singlet fermions, iso-doublet Higgs scalars or iso-triplet fermions. The iso-triplet fields can carry a zero or nonzero hypercharge. Through the decays of the heavy gauge-singlet fermions, iso-doublet scalars or iso-triplet fermions, we can obtain a lepton asymmetry inmore » the left-handed leptons and an opposite lepton asymmetry in the right-handed neutrinos. Since the right-handed neutrinos do not participate in the sphaleron processes, the left-handed lepton asymmetry can be partially converted to a baryon asymmetry.« less
NASA Technical Reports Server (NTRS)
Lim, Sang G.; Brewe, David E.; Prahl, Joseph M.
1990-01-01
The transient analysis of hydrodynamic lubrication of a point-contact is presented. A body-fitted coordinate system is introduced to transform the physical domain to a rectangular computational domain, enabling the use of the Newton-Raphson method for determining pressures and locating the cavitation boundary, where the Reynolds boundary condition is specified. In order to obtain the transient solution, an explicit Euler method is used to effect a time march. The transient dynamic load is a sinusoidal function of time with frequency, fractional loading, and mean load as parameters. Results include the variation of the minimum film thickness and phase-lag with time as functions of excitation frequency. The results are compared with the analytic solution to the transient step bearing problem with the same dynamic loading function. The similarities of the results suggest an approximate model of the point contact minimum film thickness solution.
Tsikas, Dimitrios; Suchy, Maria-Theresia
2016-04-15
Arachidonic acid, the origin of the eicosanoids family, occurs in biological samples as free acid and as ester in lipids. Free arachidonic acid is oxidized to numerous metabolites by means of enzymes including cyclooxygenase (COX). Arachidonic acid esterified to lipids is attacked by reactive oxygen species (ROS) to generate numerous oxidized arachidonic acid derivatives. Generally, it is assumed that ROS-derived arachidonic acid derivatives are distinct from those generated by enzymes such as COX. Therefore, ROS-generated eicosanoids are considered specific biomarkers of oxidative stress. However, there are serious doubts concerning a strict distinction between the enzyme-derived eicosanoids and the ROS-derived iso-eicosanoids. Prominent examples are prostaglandin F2α (PGF2α) and 15(S)-8-iso-prostaglandin F2α (15(S)-8-iso-PGF2α) which have been originally considered to exclusively derive from COX and ROS, respectively. There is convincing evidence that both COX and ROS can oxidize arachidonic acid to PGF2α and 15(S)-8-iso-PGF2α. Thus, many results previously reported for 15(S)-8-iso-PGF2α as exclusive ROS-dependent reaction product, and consequently as a specific biomarker of oxidative stress, require a careful re-examination which should also consider the analytical methods used to measure 15(S)-8-iso-PGF2α. This prominent but certainly not the only example underlines more than ever the importance of the analytical chemistry in basic and clinical research areas of oxidative stress. In the present work, we report analytical protocols for the reliable quantitative determination of 15(S)-8-iso-PGF2α in human biological samples including plasma and urine by mass spectrometry coupled to gas chromatography (GC-MS, GC-MS/MS) after specific isolation of endogenous 15(S)-8-iso-PGF2α and the externally added internal standard [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α by immunoaffinity column chromatography (IAC). 15(S)-8-iso-PGF2α esterified to plasma lipids is hydrolysed by KOH. 15(S)-8-iso-PGF2α and [3,3',4,4'-(2)H4]-15(S)-8-iso-PGF2α are analyzed as pentafluorobenzyl ester trimethylsilyl ether derivatives in the electron-capture negative-ion chemical ionization mode. Copyright © 2014 Elsevier B.V. All rights reserved.
Ramoutar, Darryl N; Crosnier, Emilie A; Shivji, Faiz; Miles, Anthony W; Gill, Harinderjit S
2017-05-01
Most femoral components used now for total hip arthroplasty are modular, requiring a strong connection at assembly. The aim of this study was to assess the effect of assembly force on the strength of head-trunnion interface and to measure the initial displacement of the head on the trunnion with different assembly forces. Three assembly load levels were assessed (A: 2 kN, B: 4 kN, C: 6 kN) with 4 implants in each group. The stems were mounted in a custom rig and the respective assembly loads were applied to the head at a constant rate of 0.05 kN/s (ISO7260-10:2003). Load levels were recorded during assembly. Head displacement was measured with a laser sensor. The disassembly force was determined by a standard pull-off test. The maximum head displacement on the trunnion was significantly different between the 2 kN group and the other 2 groups (4 kN, 6 kN, P = .029), but not between the 4 kN and 6 kN groups (P = .89). The disassembly forces between the 3 groups were significantly different (mean ± standard deviation, A: 1316 ± 223 kN; B: 2224 ± 151 kN; C: 3965 ± 344 kN; P = .007), with increasing assembly load leading to a higher pull-off force. For the 4 kN and 6 kN groups, a first peak of approximately 2.5 kN was observed on the load recordings during assembly before the required assembly load was eventually reached corresponding to sudden increase in head displacement to approximately 150 μm. An assembly force of 2 kN may be too low to overcome the frictional forces needed to engage the head and achieve maximum displacement on the trunnion and thus an assembly load of greater than 2.5 kN is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.
Mure, Kanae; Yoshimura, Noriko; Hashimoto, Marowa; Muraki, Shigeyuki; Oka, Hiroyuki; Tanaka, Sakae; Kawaguchi, Hiroshi; Nakamura, Kozo; Akune, Toru; Takeshita, Tatsuya
2015-07-01
To determine whether 8-iso-prostaglandin F2α (8-iso-PGF2α) is a reliable biomarker of the accumulation of metabolic risks [e.g., overweight, hypertension, impaired glucose tolerance (IGT), and dyslipidemia]. This was a cross-sectional study of the baseline characteristics of a Japanese general population cohort study: Research on Osteoarthritis/Osteoporosis Against Disability (ROAD). Of 1,690 participants, 1,527 fulfilled all questionnaires and examinations. Free and conjugated urinary 8-iso-PGF2α levels and metabolic syndrome (MetS) components including blood pressure, HbA1c, total cholesterol, high-density lipoprotein cholesterol (HDL-C), and non-HDL-C were analyzed. The data were analyzed by ANCOVA, multiple regression analysis, and multinomial logistic analysis. 8-iso-PGF2α was significantly associated with HbA1c and significantly inversely associated with total cholesterol and non-HDL-C. Notably, IGT with an HbA1c cut-off of 5.5% was significantly associated with 8-iso-PGF2α level in participants aged ≤50 years. Multinomial logistic regression analysis revealed 8-iso-PGF2α level was significantly associated with a greater number of MetS risks present; this association was stronger in younger participants. In participants aged ≥71 years, 8-iso-PGF2α was significantly associated with a greater number of MetS risks with higher IGT cut-offs. Urinary 8-iso-PGF2α can be a reliable marker of IGT and the accumulation of MetS risks, especially in younger people. © 2015 The Obesity Society.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-20
... System Operator, Inc. (Midwest ISO or Respondent) alleging that the Midwest ISO violated their, Midwest ISO and PJM, Joint Operating Agreement (JOA), through its practice of initiating the JOA market-to...
Querques, Lea; Querques, Giuseppe; Forte, Raimondo; Souied, Eric H
2012-06-01
To investigate the microperimetric correlations of autofluorescence imaging and optical coherence tomography (OCT) in dry age-related macular degeneration (AMD). Retrospective, observational, cross-sectional study. Consecutive patients with dry AMD underwent a complete ophthalmologic examination, including best-corrected visual acuity (BCVA), blue fundus autofluorescence (FAF), near-infrared autofluorescence, and spectral-domain (SD)-OCT with integrated microperimetry. A total of 58 eyes of 29 patients (21 women; mean age 73 ± 9 years) were included. Mean BCVA was 0.28 ± 0.3 logarithm of the minimal angle of resolution (logMAR). Overall, 2842 points were analyzed as regards FAF and near-infrared autofluorescence patterns, the status of inner segment/outer segment (IS/OS) interface, and retinal sensitivity. We observed a good correlation between the FAF and near-infrared autofluorescence patterns for all the points graded (increased FAF/near-infrared autofluorescence, Pearson rho = 0.6, P = .02; decreased FAF/near-infrared autofluorescence, Pearson rho = 0.7, P = .01; normal FAF/near-infrared autofluorescence, Pearson rho = 0.7, P = .01). Mean retinal sensitivity was significantly reduced in cases of decreased FAF (4.73 ± 2.23 dB) or increased FAF (4.75 ± 2.39 dB) compared with normal FAF (7.44 ± 2.34 dB) (P = .001). Mean retinal sensitivity was significantly reduced in case of decreased near-infrared autofluorescence (3.87 ± 2.28 dB), compared with increased near-infrared autofluorescence (5.76 ± 2.44 dB) (P = .02); mean retinal sensitivity in case of increased near-infrared autofluorescence was significantly reduced compared with normal near-infrared autofluorescence (7.15 ± 2.38 dB) (P = .002). On SD-OCT, there was a high inverse correlation between retinal sensitivity and rate of disruptions in IS/OS interface (Pearson rho = -0.72, P = .001). A reduced retinal sensitivity consistently correlates with decreased FAF/near-infrared autofluorescence and a disrupted IS/OS interface. Increased near-infrared autofluorescence may represent a useful method for detection of retinal abnormalities early in dry AMD development. Copyright © 2012 Elsevier Inc. All rights reserved.
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
14 CFR 23.507 - Jacking loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Vertical-load factor of 1.35 times the static reactions. (2) Fore, aft, and lateral load factors of 0.4 times the vertical static reactions. (b) The horizontal loads at the jack points must be reacted by...
Reliability of High-Temperature Fixed-Point Installations over 8 Years
NASA Astrophysics Data System (ADS)
Elliott, C. J.; Ford, T.; Ongrai, O.; Pearce, J. V.
2017-12-01
At NPL, high-temperature metal-carbon eutectic fixed points have been set up for thermocouple calibration purposes since 2006, for realising reference temperatures above the highest point specified in the International Temperature Scale of 1990 for contact thermometer calibrations. Additionally, cells of the same design have been provided by NPL to other national measurement institutes (NMIs) and calibration laboratories over this period, creating traceable and ISO 17025 accredited facilities around the world for calibrating noble metal thermocouples at 1324 {°}C (Co-C) and 1492 {°}C (Pd-C). This paper shows collections of thermocouple calibration results obtained during use of the high-temperature fixed-point cells at NPL and, as further examples, the use of cells installed at CCPI Europe (UK) and NIMT (Thailand). The lifetime of the cells can now be shown to be in excess of 7 years, whether used on a weekly or monthly basis, and whether used in an NMI or industrial calibration laboratory.
2008-03-01
maturity models and ISO standards, specifically CMMI, CMMI-ACQ and ISO 12207 . Also, the improvement group supplemented their selection of these...compliant with the technologies and standards that are important to the business. Lockheed Martin IS&GS has integrated CMMI, EIA 632, ISO 12207 , and Six...geographically dispersed organization. [Siviy 07-1] Northrop Grumman Mission Systems has integrated CMMI, ISO 9001, AS9100, and Six Sigma, as well as a
2007-05-01
partners will be encouraged to use the assessment methodologies referenced above, or ISO 27001 and ISO 17799, which are intended to be used together...the Information Systems Audit and Control Association (ISACA), the International Organization for Standardization ( ISO ), and a number of other...programs are aligned with NCSD’s goals for the IT sector and follow best practices developed by NIST and the ISO . The cyber protective programs
ISO 9000 Quality Management System
NASA Astrophysics Data System (ADS)
Hadjicostas, Evsevios
The ISO 9000 series describes a quality management system applicable to any organization. In this chapter we present the requirements of the standard in a way that is as close as possible to the needs of analytical laboratories. The sequence of the requirements follows that in the ISO 9001:2008 standard. In addition, the guidelines for performance improvement set out in the ISO 9004 are reviewed. Both standards should be used as a reference as well as the basis for further elaboration.
Zha, Jian-peng; Lin, Ying; Yang, Xing-hui; Hou, Hai-ni; Wei, Tie-jun; Chen, Xing-li
2002-06-01
Fluorescence enhancement of anhydrotetracycline hydrochloride and iso-tetracycline has been described. The fluorescence intensities of anhydrotetracycline hydrochloride and iso-tetracycline with cetyltrimethylammonium bromide (CTMAB) enhanced by micellar solution have been examined. It is found that fluorescence enhancement of anhydrotetracycline hydrochloride and iso-tetracycline depends on the concentration of CTMAB and pH of the solution. It can be used to develop sensitive methods for the determination of tetracycline hydrochloride and its decomposition product.
Fang, Yong; Cao, Zipeng; Hou, Qi; Ma, Chen; Yao, Chunsuo; Li, Jingxia; Wu, Xue-Ru; Huang, Chuanshu
2013-01-01
Isorhapontigenin (ISO) is a new derivative of stilbene compound that was isolated from the Chinese herb Gnetum Cleistostachyum, and has been used for treatment of bladder cancers for centuries. In our current studies, we have explored the potential inhibitory effect and molecular mechanisms underlying ISO anti-cancer effects on anchorage-independent growth of human bladder cancer cell lines. We found that ISO showed a significant inhibitory effect on human bladder cancer cell growth and was accompanied with related cell cycle G0/G1 arrest as well as downregulation of Cyclin D1 expression at the transcriptional level in UMUC3 and RT112 cells. Further studies identified that ISO down-regulated Cyclin D1 gene transcription via inhibition of SP1 transactivation. Moreover, ectopic expression of GFP-Cyclin D1 rendered UMUC3 cells resistant to induction of cell cycle G0/G1 arrest and inhibition of cancer cell anchorage-independent growth by ISO treatment. Together, our studies demonstrate that ISO is an active compound that mediates for Gnetum Cleistostachyum’s induction of cell cycle G0/G1 arrest and inhibition of cancer cell anchorage-independent growth through down-regulating SP1/Cyclin D1 axis in bladder cancer cells. Our studies provide a novel insight into understanding the anti-cancer activity of the Chinese herb Gnetum Cleistostachyum and its isolate ISO. PMID:23723126
The ISO Data Archive and Interoperability with Other Archives
NASA Astrophysics Data System (ADS)
Salama, Alberto; Arviset, Christophe; Hernández, José; Dowson, John; Osuna, Pedro
The ESA's Infrared Space Observatory (ISO), an unprecedented observatory for infrared astronomy launched in November 1995, successfully made nearly 30,000 scientific observations in its 2.5-year mission. The ISO data can be retrieved from the ISO Data Archive, available at ISO Data Archive , and comprised of about 150,000 observations, including parallel and serendipity mode observations. A user-friendly Java interface permits queries to the database and data retrieval. The interface currently offers a wide variety of links to other archives, such as name resolution with NED and SIMBAD, access to electronic articles from ADS and CDS/VizieR, and access to IRAS data. In the past year development has been focused on improving the IDA interoperability with other astronomical archives, either by accessing other relevant archives or by providing direct access to the ISO data for external services. A mechanism of information transfer has been developed, allowing direct query to the IDA via a Java Server Page, returning quick look ISO images and relevant, observation-specific information embedded in an HTML page. This method has been used to link from the CDS/Vizier Data Centre and ADS, and work with IPAC to allow access to the ISO Archive from IRSA, including display capabilities of the observed sky regions onto other mission images, is in progress. Prospects for further links to and from other archives and databases are also addressed.
Plasma 8-iso-Prostaglandin F2α concentrations and outcomes after acute intracerebral hemorrhage.
Du, Quan; Yu, Wen-Hua; Dong, Xiao-Qiao; Yang, Ding-Bo; Shen, Yong-Feng; Wang, Hao; Jiang, Li; Du, Yuan-Feng; Zhang, Zu-Yong; Zhu, Qiang; Che, Zhi-Hao; Liu, Qun-Jie
2014-11-01
Higher plasma 8-iso-Prostaglandin F2α concentrations have been associated with poor outcome of severe traumatic brain injury. We further investigated the relationships between plasma 8-iso-Prostaglandin F2α concentrations and clinical outcomes in patients with acute intracerebral hemorrhage. Plasma 8-iso-Prostaglandin F2α concentrations of 128 consecutive patients and 128 sex- and gender-matched healthy subjects were measured by enzyme-linked immunosorbent assay. We assessed their relationships with disease severity and clinical outcomes including 1-week mortality, 6-month mortality and unfavorable outcome (modified Rankin Scale score>2). Plasma 8-iso-Prostaglandin F2α concentrations were substantially higher in patients than in healthy controls. Plasma 8-iso-Prostaglandin F2α concentrations were positively associated with National Institutes of Health Stroke Scale (NIHSS) scores and hematoma volume using a multivariate linear regression. It emerged as an independent predictor for clinical outcomes of patients using a forward stepwise logistic regression. ROC curves identified the predictive values of plasma 8-iso-Prostaglandin F2α concentrations, and found its predictive value was similar to NIHSS scores and hematoma volumes. However, it just numerically added the predictive values of NIHSS score and hematoma volume. Increased plasma 8-iso-Prostaglandin F2α concentrations are associated with disease severity and clinical outcome after acute intracerebral hemorrhage. Copyright © 2014 Elsevier B.V. All rights reserved.