Dolciami, Daniela; Gargaro, Marco; Cerra, Bruno; Scalisi, Giulia; Bagnoli, Luana; Servillo, Giuseppe; Fazia, Maria Agnese Della; Puccetti, Paolo; Quintana, Francisco J; Fallarino, Francesca; Macchiarulo, Antonio
2018-02-06
Discovered as a modulator of the toxic response to environmental pollutants, aryl hydrocarbon receptor (AhR) has recently gained attention for its involvement in various physiological and pathological pathways. AhR is a ligand-dependent transcription factor activated by a large array of chemical compounds, which include metabolites of l-tryptophan (l-Trp) catabolism as endogenous ligands of the receptor. Among these, 2-(1'H-indole-3'-carbonyl)thiazole-4-carboxylic acid methyl ester (ITE) has attracted interest in the scientific community, being endowed with nontoxic, immunomodulatory, and anticancer AhR-mediated functions. So far, no information about the binding mode and interactions of ITE with AhR is available. In this study, we used docking and molecular dynamics to propose a putative binding mode of ITE into the ligand binding pocket of AhR. Mutagenesis studies were then instrumental in validating the proposed binding mode, identifying His 285 and Tyr 316 as important key residues for ligand-dependent receptor activation. Finally, a set of ITE analogues was synthesized and tested to further probe molecular interactions of ITE to AhR and characterize the relevance of specific functional groups in the chemical structure for receptor activity. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Factors affecting the use and perceived benefit of ITE and BTE hearing aids.
Baumfield, A; Dillon, H
2001-08-01
The aim of the present study was to investigate factors that might affect hearing aid use, satisfaction and perceived benefit. A further aim was to look at which variables affect the choice of hearing aid, in particular, an in-the-ear (ITE) versus a behind-the-ear (BTE) device. Twenty-nine elderly hearing-impaired people with a mild-to-moderate hearing loss were fitted with both an ITE and a BTE hearing aid with similar electroacoustic performance. Both hearing aids were linear with output compression limiting and were fitted in a randomized order. After wearing each device for a six-week period, subj ets were asked to select the hearing aid they preferred. Variables significantly related to hearing aid choice, use and perceived benefit included ease of management, accuracy with which the NAL-R insertion gain target was achieved, earmould comfort and the type of hearing aid the client preferred initially.
U.S. Naval Forces, Vietnam Monthly Historical Summary for July 1969
1969-10-01
accounted for 28 YC, killed and 20 captured. During the last 8 days of Tuly RAC on patrol duties and those in blocking tetions after troop insertions...casialties vere unkiowz. The only other * incident Involving RAC occurred on 27 Tuly when RAC, ebile Sw iting to backload troops, took a *sup= under
NASA Astrophysics Data System (ADS)
Mackeen, Cameron; Bridges, Frank; Kozina, Michael; Mehta, Apurva; Reid, M. F.; Wells, J.-P. R.; BarandiaráN, Zoila
Fluorite crystal structures doped with rare-earth elements exhibit an anomalous redshifted luminescence upon UV excitation, generally attributed to the relaxation of impurity trapped excitons (ITE). We find that the intensity of this luminescence decreases as the total concentration of Yb 2+ increases in unexposed samples, which is in conflict with the currently accepted ITE model. Further, using x-ray absorption spectroscopy and UV-vis studies of CaF2:Yb, we find a large (but reversible) Yb valence reduction upon x-ray exposure at 200 K - from mostly 3+ to 2+. This valence reduction is stable for long time periods at low T < 50 K, but reverts to the initial state upon warming to 300 K. After reverting to the initial valence state of 3+ the anomalous luminescence does not reappear; only after annealing at 900 K do we again observe the anomalous emission below 150 K. To explore the mechanism at work, we employ extended x-ray fine-structure absorption spectroscopy (EXAFS) to probe local structure and its role in the anomalous luminescence. The x-ray and emission studies show that CaF2:Yb is not described by the ITE model; the data appear more consistent with an intervalence charge transfer (IVCT) model. It is likely that many similar ITE systems have also been misidentified.
Conference attendance and performance on the in-training examination in internal medicine.
Cacamese, Suzanne M; Eubank, Kathryn J; Hebert, Randy S; Wright, Scott M
2004-11-01
The objective of this study was to describe the relationship between attendance at conferences during residency training and residents' performance on the In-Training Examination (ITE) in Internal Medicine. Nineteen house officers participated in the study. Conference attendance records were retrospectively reviewed for the one-year period preceding the ITE (pre-ITE), and in the three-month period after house officers received their ITE scores (post-ITE). After receiving their scores, participants completed a questionnaire asking about study habits and opinions about conferences. Attendance was taken at 126/165 (76.4%) conferences pre-ITE and 32/42 (76.2%) conferences post-ITE. House officers attended a mean of 35% (range, 10-59) of the conferences pre-ITE and 32% (range, 9-75) post-ITE (p = 0.365). There was no correlation between prior conference attendance and ITE scores (Spearman correlation coefficient -0.230, p = 0.34), and no correlation between score and conference attendance post-ITE (Spearman correlation coefficient 0.174, p = 0.48). Participation in clinical rotations also failed to influence ITE scores in that content area (all p > 0.05). The findings of this study suggest conference attendance does not influence ITE scores. Medical educators may need to rethink and study how best to impart medical knowledge.
Zeger, Scott L.; Kolars, Joseph C.
2008-01-01
Background Little is known about the associations of previous standardized examination scores with scores on subsequent standardized examinations used to assess medical knowledge in internal medicine residencies. Objective To examine associations of previous standardized test scores on subsequent standardized test scores. Design Retrospective cohort study. Participants One hundred ninety-five internal medicine residents. Methods Bivariate associations of United States Medical Licensing Examination (USMLE) Steps and Internal Medicine In-Training Examination (IM-ITE) scores were determined. Random effects analysis adjusting for repeated administrations of the IM-ITE and other variables known or hypothesized to affect IM-ITE score allowed for discrimination of associations of individual USMLE Step scores on IM-ITE scores. Results In bivariate associations, USMLE scores explained 17% to 27% of the variance in IME-ITE scores, and previous IM-ITE scores explained 66% of the variance in subsequent IM-ITE scores. Regression coefficients (95% CI) for adjusted associations of each USMLE Step with IM-ITE scores were USMLE-1 0.19 (0.12, 0.27), USMLE-2 0.23 (0.17, 0.30), and USMLE-3 0.19 (0.09, 0.29). Conclusions No single USMLE Step is more strongly associated with IM-ITE scores than the others. Because previous IM-ITE scores are strongly associated with subsequent IM-ITE scores, appropriate modeling, such as random effects methods, should be used to account for previous IM-ITE administrations in studies for which IM-ITE score is an outcome. PMID:18612735
McDonald, Furman S; Zeger, Scott L; Kolars, Joseph C
2008-07-01
Little is known about the associations of previous standardized examination scores with scores on subsequent standardized examinations used to assess medical knowledge in internal medicine residencies. To examine associations of previous standardized test scores on subsequent standardized test scores. Retrospective cohort study. One hundred ninety-five internal medicine residents. Bivariate associations of United States Medical Licensing Examination (USMLE) Steps and Internal Medicine In-Training Examination (IM-ITE) scores were determined. Random effects analysis adjusting for repeated administrations of the IM-ITE and other variables known or hypothesized to affect IM-ITE score allowed for discrimination of associations of individual USMLE Step scores on IM-ITE scores. In bivariate associations, USMLE scores explained 17% to 27% of the variance in IME-ITE scores, and previous IM-ITE scores explained 66% of the variance in subsequent IM-ITE scores. Regression coefficients (95% CI) for adjusted associations of each USMLE Step with IM-ITE scores were USMLE-1 0.19 (0.12, 0.27), USMLE-2 0.23 (0.17, 0.30), and USMLE-3 0.19 (0.09, 0.29). No single USMLE Step is more strongly associated with IM-ITE scores than the others. Because previous IM-ITE scores are strongly associated with subsequent IM-ITE scores, appropriate modeling, such as random effects methods, should be used to account for previous IM-ITE administrations in studies for which IM-ITE score is an outcome.
Singh, Sagar; Lo, Meng-Chen; Damodaran, Vinod B.; Kaplan, Hilton M.; Kohn, Joachim; Zahn, Jeffrey D.; Shreiber, David I.
2016-01-01
Single-unit recording neural probes have significant advantages towards improving signal-to-noise ratio and specificity for signal acquisition in brain-to-computer interface devices. Long-term effectiveness is unfortunately limited by the chronic injury response, which has been linked to the mechanical mismatch between rigid probes and compliant brain tissue. Small, flexible microelectrodes may overcome this limitation, but insertion of these probes without buckling requires supporting elements such as a stiff coating with a biodegradable polymer. For these coated probes, there is a design trade-off between the potential for successful insertion into brain tissue and the degree of trauma generated by the insertion. The objective of this study was to develop and validate a finite element model (FEM) to simulate insertion of coated neural probes of varying dimensions and material properties into brain tissue. Simulations were performed to predict the buckling and insertion forces during insertion of coated probes into a tissue phantom with material properties of brain. The simulations were validated with parallel experimental studies where probes were inserted into agarose tissue phantom, ex vivo chick embryonic brain tissue, and ex vivo rat brain tissue. Experiments were performed with uncoated copper wire and both uncoated and coated SU-8 photoresist and Parylene C probes. Model predictions were found to strongly agree with experimental results (<10% error). The ratio of the predicted buckling force-to-predicted insertion force, where a value greater than one would ideally be expected to result in successful insertion, was plotted against the actual success rate from experiments. A sigmoidal relationship was observed, with a ratio of 1.35 corresponding to equal probability of insertion and failure, and a ratio of 3.5 corresponding to a 100% success rate. This ratio was dubbed the “safety factor”, as it indicated the degree to which the coating should be over-designed to ensure successful insertion. Probability color maps were generated to visually compare the influence of design parameters. Statistical metrics derived from the color maps and multi-variable regression analysis confirmed that coating thickness and probe length were the most important features in influencing insertion potential. The model also revealed the effects of manufacturing flaws on insertion potential. PMID:26959021
Correlation of USMLE Step 1 scores with performance on dermatology in-training examinations.
Fening, Katherine; Vander Horst, Anthony; Zirwas, Matthew
2011-01-01
Although United States Medical Licensing Examination (USMLE) Step 1 was not designed to predict resident performance, scores are used to compare residency applicants. Multiple studies have displayed a significant correlation among Step 1 scores, in-training examination (ITE) scores, and board passage, although no such studies have been performed in dermatology. The purpose of this study is to determine if this correlation exists in dermatology, and how much of the variability in ITE scores is a result of differences in Step 1 scores. This study also seeks to determine if it is appropriate to individualize expectations for resident ITE performance. This project received institutional review board exemption. From 5 dermatology residency programs (86 residents), we collected Step 1 and ITE scores for each of the 3 years of dermatology residency, and recorded passage/failure on boards. Bivariate Pearson correlation analysis was used to assess correlation between USMLE and ITE scores. Ordinary least squares regression was computed to determine how much USMLE scores contribute to ITE variability. USMLE and ITE score correlations were highly significant (P < .001). Correlation coefficients with USMLE were: 0.467, 0.541, and 0.527 for ITE in years 1, 2, and 3, respectively. Variability in ITE scores caused by differences in USMLE scores were: ITE first-year residency = 21.8%, ITE second-year residency = 29.3%, and ITE third-year residency = 27.8%. This study had a relatively small sample size, with data from only 5 programs. There is a moderate correlation between USMLE and ITE scores, with USMLE scores explaining ∼26% of the variability in ITE scores. Copyright © 2009 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Robot friendly probe and socket assembly
NASA Technical Reports Server (NTRS)
Nyberg, Karen L. (Inventor)
1994-01-01
A probe and socket assembly for serving as a mechanical interface between structures is presented. The assembly comprises a socket having a housing adapted for connection to a first supporting structure and a probe which is readily connectable to a second structure and is designed to be easily grappled and manipulated by a robotic device for insertion and coupling with the socket. Cooperable automatic locking means are provided on the probe shaft and socket housing for automatically locking the probe in the socket when the probe is inserted a predetermined distance. A second cooperable locking means on the probe shaft and housing are adapted for actuation after the probe has been inserted the predetermined distance. Actuation means mounted on the probe and responsive to the grip of the probe handle by a gripping device, such as a robot for conditioning the probe for insertion and are also responsive to release of the grip of the probe handle to actuate the second locking means to provide a hard lock of the probe in the socket.
Rigid spine reinforced polymer microelectrode array probe and method of fabrication
Tabada, Phillipe; Pannu, Satinderpall S
2014-05-27
A rigid spine-reinforced microelectrode array probe and fabrication method. The probe includes a flexible elongated probe body with conductive lines enclosed within a polymeric material. The conductive lines connect microelectrodes found near an insertion end of the probe to respective leads at a connector end of the probe. The probe also includes a rigid spine, such as made from titanium, fixedly attached to the probe body to structurally reinforce the probe body and enable the typically flexible probe body to penetrate and be inserted into tissue, such as neural tissue. By attaching or otherwise fabricating the rigid spine to connect to only an insertion section of the probe body, an integrally connected cable section of the probe body may remain flexible.
Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion
Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B.; Kaplan, Hilton M.; Kohn, Joachim; Shreiber, David I.; Zahn, Jeffrey D.
2016-01-01
We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings. PMID:25681971
Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion.
Lo, Meng-chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B; Kaplan, Hilton M; Kohn, Joachim; Shreiber, David I; Zahn, Jeffrey D
2015-04-01
We report a fabrication process for coating neural probes with an ultrafast degrading polymer to create consistent and reproducible devices for neural tissue insertion. The rigid polymer coating acts as a probe insertion aid, but resorbs within hours post-implantation. Despite the feasibility for short term neural recordings from currently available neural prosthetic devices, most of these devices suffer from long term gliosis, which isolates the probes from adjacent neurons, increasing the recording impedance and stimulation threshold. The size and stiffness of implanted probes have been identified as critical factors that lead to this long term gliosis. Smaller, more flexible probes that match the mechanical properties of brain tissue could allow better long term integration by limiting the mechanical disruption of the surrounding tissue during and after probe insertion, while being flexible enough to deform with the tissue during brain movement. However, these small flexible probes inherently lack the mechanical strength to penetrate the brain on their own. In this work, we have developed a micromolding method for coating a non-functional miniaturized SU-8 probe with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)). Coated, non-functionalized probes of varying dimensions were reproducibly fabricated with high yields. The polymer erosion/degradation profiles of the probes were characterized in vitro. The probes were also mechanically characterized in ex vivo brain tissue models by measuring buckling and insertion forces during probe insertion. The results demonstrate the ability to produce polymer coated probes of consistent quality for future in vivo use, for example to study the effects of different design parameters that may affect tissue response during long term chronic intra-cortical microelectrode neural recordings.
Membrane Insertion Profiles of Peptides Probed by Molecular Dynamics Simulations
2008-07-17
Membrane insertion profiles of peptides probed by molecular dynamics simulations In-Chul Yeh,* Mark A. Olson,# Michael S. Lee,*#§ and Anders...a methodology based on molecular dynamics simulation techniques to probe the insertion profiles of small peptides across the membrane interface. The...profiles of peptides probed by molecular dynamics simulations 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d
Althouse, Linda A; McGuinness, Gail A
2008-09-01
This study investigates the predictive validity of the In-Training Examination (ITE). Although studies have confirmed the predictive validity of ITEs in other medical specialties, no study has been done for general pediatrics. Each year, residents in accredited pediatric training programs take the ITE as a self-assessment instrument. The ITE is similar to the American Board of Pediatrics General Pediatrics Certifying Examination. First-time takers of the certifying examination over a 5-year period who took at least 1 ITE examination were included in the sample. Regression models analyzed the predictive value of the ITE. The predictive power of the ITE in the first training year is minimal. However, the predictive power of the ITE increases each year, providing the greatest power in the third year of training. Even though ITE scores provide information regarding the likelihood of passing the certification examination, the data should be used with caution, particularly in the first training year. Other factors also must be considered when predicting performance on the certification examination. This study continues to support the ITE as an assessment tool for program directors, as well as a means of providing residents with feedback regarding their acquisition of pediatric knowledge.
Cho, Jung-Jin; Kim, Ji-Yong
2011-09-01
In-training examination (ITE) is a cognitive examination similar to the written test, but it is different from the Clinical Practice Examination of the Korean Academy of Family Medicine (KAFM) Certification Examination (CE). The objective of this is to estimate the positive predictive value of the KAFM-ITE for identifying residents at risk for poor performance on the three types of KAFM-CE. 372 residents who completed the KAFM-CE in 2011 were included. We compared the mean KAFM-CE scores with ITE experience. We evaluated the correlation and the positive predictive value (PPV) of ITE for the multiple choice question (MCQ) scores of 1st written test & 2nd slide examination, the total clinical practice examination scores, and the total sum of 2nd test. 275 out of 372 residents completed ITE. Those who completed ITE had significantly higher MCQ scores of 1st written test than those who did not. The correlation of ITE scores with 1st written MCQ (0.627) was found to be the highest among the other kinds of CE. The PPV of the ITE score for 1st written MCQ scores was 0.672. The PPV of the ITE score ranged from 0.376 to 0.502. The score of the KAFM ITE has acceptable positive predictive value that could be used as a part of comprehensive evaluation system for residents in cognitive field.
Design and testing of microfabricated surgical tools for large animal probe insertion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jorgensen, Shelly
Neural probes provide therapeutic stimulation for neuropsychiatric disorders or record neural activity to investigate the workings of the brain. Researchers utilize 6 mm long temporary silicon stiffeners attached with biodissolvable adhesive to insert flexible neural probes into rat brains, but increasing the probe length fivefold makes inserting large animal probes a significant challenge because of an increased potential for buckling. This study compared the insertion success rates of 6 mm and 30 mm long silicon stiffeners that were 80 μm wide and 30 μm thick, and ascertained the material thickness and modulus of elasticity that would provide successful insertion formore » a 30 mm probe. Using a microdrive, stiffeners were inserted into an agarose brain phantom at controlled insertion speeds while being video-recorded. Twenty-five percent of the 30 mm silicon stiffeners fully inserted at speeds approximately four times higher than the target rate of 0.13 mm/s, while 100 percent of the 6 mm silicon stiffeners inserted successfully at target speed. Critical buckling loads (P cr) were calculated for the 6 mm and 30 mm silicon stiffeners, and for 30 mm diamond and tungsten stiffeners, with thicknesses varying from 30-80 μm. Increasing the thickness of the material by 10 μm, 20 μm and 30 μm improved the P cr by 2.4, 4.7 and 8.2 times, respectively, independent of the material, and substituting diamond for silicon multiplied the buckling capacity by 5.0 times. Stiffeners made of silicon for large animal probe insertion are not strong enough to withstand buckling upon insertion without a significant increase in thickness. Replacing silicon with diamond and increasing the thickness of the stiffener to 50 μm would afford a stiffener with the same P cr capacity as the 6 mm silicon stiffener that had a 100 percent insertion success rate. Experiments should continue with diamond to determine a minimum thickness that will ensure successful insertions and provide an adequate margin of safety.« less
Joseph, Julie A; Terry, Chris M; Waller, Eva J; Bortsov, Andrey V; Zvara, David A; Mayer, David C; Martinelli, Susan M
2014-01-01
Anesthesiology resident physicians across the United States complete an annual in-training examination (ITE). The ITE evaluates resident knowledge and provides personalized feedback to guide future study in low scoring sections(1). Performance on the ITE correlates with outcomes on the American Board of Anesthesiology (ABA) written board examination(2). Over the last several years, declining ITE scores were observed at the University of North Carolina (UNC). In response to this decline, our department reprioritized the ITE by instituting an academic improvement policy (AIP). The AIP employed both reward for satisfactory achievement and consequence for under-performance to elevate the ITE as a "high stakes" examination. Our hypothesis was that implementation of this AIP would improve ITE scores. ITE scores were compiled from 150 residents in the Department of Anesthesiology at UNC for graduating classes from 2004-2015. Data is presented as the number of residents scoring below the 20th percentile when compared to the national distribution before and after the AIP. In addition, average USMLE Step 1 three-digit scores for each graduating class were compared to average ITE percentile scores of the corresponding graduating class (USMLE does not provide percentile scores). Between 2009 and 2013, the number of residents who scored below the 20th percentile on the ITE increased steadily to a peak of 10 in 2011. After implementation of the AIP in July 2011, there was an 80% decrease in those scoring below the 20th percentile, from 10 to 2 residents (p<0.05). Anesthesiology resident ITE scores improved after implementation of an academic improvement policy.
NASA Astrophysics Data System (ADS)
Harashima, Takuya; Morikawa, Takumi; Kino, Hisashi; Fukushima, Takafumi; Tanaka, Tetsu
2017-04-01
A Si neural probe is one of the most important tools for neurophysiology and brain science because of its various functions such as optical stimulation and drug delivery. However, the Si neural probe is not robust compared with a metal tetrode, and could be broken by mechanical stress caused by insertion to the brain. Therefore, the Si neural probe becomes more useful if it has a stress sensor that can measure mechanical forces applied to the probe so as not to be broken. In this paper, we proposed and fabricated the Si neural probe with a piezoresistive force sensor for minimally invasive and precise monitoring of insertion forces. The fabricated piezoresistive force sensor accurately measured forces and successfully detected insertion events without buckling or bending in the shank of the Si neural probe. This Si neural probe with a piezoresistive force sensor has become one of the most versatile tools for neurophysiology and brain science.
Ma, Tao; Cao, Ying-Lin; Xu, Bei-Bei; Zhou, Xiao-Mian
2004-06-01
The effect of (3,5,6-trimethylpyrazin-2-yl)methyl 2-[4-(2-methylpropyl)phenyl]propanoate (ITE) on type II collagen (CII)-induced arthritis in mice was studied. Mice were immunized twice with CII, ITE being given orally once a day for 40 d after the 1st immunization. Clinical assessment showed that ITE had no effect on the day of onset of arthritis but did lowered the incidence rate of arthritis and the arthritis score. And ITE had a marked suppressive effect on the mouse hind paw edema induced by CII. ITE suppressed the delayed-type mouse ear skin reaction to CII but had no effect on the level of serum anti-CII antibodies. These results suggest that ITE inhibits the development of CII-induced arthritis in mice by suppressing delayed-type hypersensitivity to CII.
Li, Yan; Wang, Kai; Zou, Qing-Yun; Jiang, Yi-Zhou; Zhou, Chi; Zheng, Jing
2017-12-01
Aryl hydrocarbon receptor (AhR), a ligand-activated transcription factor is involved in regulation of many essential biological processes including vascular development and angiogenesis. 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) is an AhR ligand, which regulates immune responses and cancer cell growth. However, the roles of the ITE/AhR pathway in mediating placental angiogenesis remains elusive. Here, we determined if ITE affected placental angiogenic responses via AhR in human umbilical vein (HUVECs) and artery endothelial (HUAECs) cells in vitro. We observed that ITE dose- and time-dependently inhibited proliferation and viability of HUAECs and HUVECs, whereas it inhibited migration of HUAECs, but not HUVECs. While AhR siRNA significantly suppressed AhR protein expression in HUVECs and HUAECs, it attenuated the ITE-inhibited angiogenic responses of HUAECs, but not HUVECs. Collectively, ITE suppressed angiogenic responses of HUAECs and HUVECs, dependent and independent of AhR, respectively. These data suggest that ITE may regulate placental angiogenesis. Copyright © 2017 Elsevier Inc. All rights reserved.
Kim, Ji-Yong
2011-01-01
Background In-training examination (ITE) is a cognitive examination similar to the written test, but it is different from the Clinical Practice Examination of the Korean Academy of Family Medicine (KAFM) Certification Examination (CE). The objective of this is to estimate the positive predictive value of the KAFM-ITE for identifying residents at risk for poor performance on the three types of KAFM-CE. Methods 372 residents who completed the KAFM-CE in 2011 were included. We compared the mean KAFM-CE scores with ITE experience. We evaluated the correlation and the positive predictive value (PPV) of ITE for the multiple choice question (MCQ) scores of 1st written test & 2nd slide examination, the total clinical practice examination scores, and the total sum of 2nd test. Results 275 out of 372 residents completed ITE. Those who completed ITE had significantly higher MCQ scores of 1st written test than those who did not. The correlation of ITE scores with 1st written MCQ (0.627) was found to be the highest among the other kinds of CE. The PPV of the ITE score for 1st written MCQ scores was 0.672. The PPV of the ITE score ranged from 0.376 to 0.502. Conclusion The score of the KAFM ITE has acceptable positive predictive value that could be used as a part of comprehensive evaluation system for residents in cognitive field. PMID:22745873
Sano, Yuzou; Morris, Hugh; Shimada, Hiroshi; Ronse De Craene, Louis P.; Jansen, Steven
2011-01-01
Background and Aims Imperforate tracheary elements (ITEs) in wood of vessel-bearing angiosperms may or may not transport water. Despite the significance of hydraulic transport for defining ITE types, the combination of cell structure with water transport visualization in planta has received little attention. This study provides a quantitative analysis of structural features associated with the conductive vs. non-conductive nature of ITEs. Methods Visualization of water transport was studied in 15 angiosperm species by dye injection and cryo-scanning electron microscopy. Structural features of ITEs were examined using light and electron microscopy. Key Results ITEs connected to each other by pit pairs with complete pit membranes contributed to water transport, while cells showing pit membranes with perforations up to 2 µm were hydraulically not functional. A close relationship was found between pit diameter and pit density, with both characters significantly higher in conductive than in non-conductive cells. In species with both conductive and non-conductive ITEs, a larger diameter was characteristic of the conductive cells. Water transport showed no apparent relationship with the length of ITEs and vessel grouping. Conclusions The structure and density of pits between ITEs represent the main anatomical characters determining water transport. The pit membrane structure of ITEs provides a reliable, but practically challenging, criterion to determine their conductive status. It is suggested that the term tracheids should strictly be used for conductive ITEs, while fibre-tracheids and libriform fibres are non-conductive. PMID:21385773
Henry, E C; Bemis, J C; Henry, O; Kende, A S; Gasiewicz, T A
2006-06-01
The aryl hydrocarbon receptor (AhR) is best known as a mediator of toxicity of a diverse family of xenobiotic chemicals such as dioxins and PCBs. However, many naturally occurring compounds also activate AhR. One such compound, 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), was isolated from tissue and found to be potent in preliminary tests [J. Song, M. Clagett-Dame, R.E. Peterson, M.E. Hahn, W.M. Westler, R.R. Sicinski, H.F. DeLuca, Proc. Natl. Acad. Sci. USA 99 (2002) 14694-14699]. We have synthesized ITE and [(3)H]ITE and further evaluated its AhR activity in several in vitro and in vivo assays in comparison with the toxic ligand, TCDD. AhR in Hepa1c1c7 cell cytosol bound [(3)H]ITE with high affinity and the AhR.ITE complex formed in vitro bound dioxin response element (DRE) oligonucleotide as potently as TCDD.AhR. In cells treated with ITE, nuclear translocation of AhR, and induction of CYP1A1 protein and of a DRE-dependent luciferase reporter gene were observed. ITE administered to pregnant DRE-LacZ transgenic mice activated fetal AhR, observed as X-gal staining in the same sites as in TCDD-treated mice. However, unlike TCDD, ITE did not induce cleft palate or hydronephrosis. TCDD but not ITE induced thymic atrophy in young adult mice, but both ITE and TCDD caused similar loss of cells and alterations of cell profiles in cultured fetal thymi. These data demonstrate that ITE is a potent AhR agonist in cell extracts, cultured cells, and intact animals, but does not cause the toxicity associated with the more stable xenobiotic ligand, TCDD.
1991-07-22
suggesting that the effect may be ite td’ phonon-assisted transitions of local degrees of freedom around the pentacene defect whose source remains to...the effect may be due to phonon-assisted transitions of local degrees of freedom around the pentacene defect whose source remains to be identified...single molecule of pentacene in p-terphenyl is an exquisitely sensitive probe of the detailed local environment around the impurity molecule. It appears
Balaban, Onur; Kamata, Mineto; Hakim, Mumin; Tumin, Dmitry; Tobias, Joseph D
2017-04-01
Given the size of the esophagogastroduodenoscopy (EGD) probe and the compressibility of the pediatric airway, the EGD probe may increase the intracuff pressure (IP) of an airway device. The current study evaluated IP changes during EGD examination under general anesthesia in pediatric patients. Following the induction of anesthesia, a laryngeal mask airway (LMA) or endotracheal tube (ETT) was placed without neuromuscular blockade. The IP was measured at baseline, during EGD probe insertion, while the EGD probe was in place, and after probe removal. The study cohort included 101 patients (mean age 11.3 years). The airway was secured with an LMA and an ETT in 88 and 13 patients, respectively. The IP increased from 27 ± 15 cmH 2 O at baseline to 34 ± 17 cmH 2 O during probe insertion (p < 0.001), remained at 33 ± 16 cmH 2 O while the probe was in place, and decreased to 26 ± 14 cmH 2 O after probe removal. The IP of the LMA or ETT increased during EGD probe insertion and remained elevated while the probe was in place. High IP may compromise mucosal perfusion resulting in a sore throat when using an LMA or the potential for airway damage if an ETT is used. Removal of air from the cuff and titration of the IP should be considered after EGD insertion.
Assessing the predictive value of the American Board of Family Practice In-training Examination.
Replogle, William H; Johnson, William D
2004-03-01
The American Board of Family Practice In-training Examination (ABFP ITE) is a cognitive examination similar in content to the ABFP Certification Examination (CE). The ABFP ITE is widely used in family medicine residency programs. It was originally developed and intended to be used for assessment of groups of residents. Despite lack of empirical support, however, some residency programs are using ABFP ITE scores as individual resident performance indicators. This study's objective was to estimate the positive predictive value of the ABFP ITE for identifying residents at risk for poor performance on the ABFP CE or a subsequent ABFP ITE. We used a normal distribution model for correlated test scores and Monte Carlo simulation to investigate the effect of test reliability (measurement errors) on the positive predictive value of the ABFP ITE. The positive predictive value of the composite score was .72. The positive predictive value of the eight specialty subscales ranged from .26 to .57. Only the composite score of the ABFP ITE has acceptable positive predictive value to be used as part of a comprehension resident evaluation system. The ABFP ITE specialty subscales do not have sufficient positive predictive value or reliability to warrant use as performance indicators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Wenguang, E-mail: zhwg@sjtu.edu.cn; Ma, Yakun; Li, Zhengwei
Purpose: The application of neural probes in clinic has been challenged by probes’ short lifetime when implanted into brain tissue. The primary goal is to develop an evaluation system for testing brain tissue injury induced by neural probe’s insertion using microscope based digital image correlation method. Methods: A brain tissue phantom made of silicone rubber with speckle pattern on its surface was fabricated. To obtain the optimal speckle pattern, mean intensity gradient parameter was used for quality assessment. The designed testing system consists of three modules: (a) load module for simulating neural electrode implantation process; (b) data acquisition module tomore » capture micrographs of speckle pattern and to obtain reactive forces during the insertion of the probe; (c) postprocessing module for extracting tissue deformation information from the captured speckle patterns. On the basis of the evaluation system, the effects of probe wedge angle, insertion speed, and probe streamline on insertion induced tissue injury were investigated. Results: The optimal quality speckle pattern can be attained by the following fabrication parameters: spin coating rate—1000 r/min, silicone rubber component A: silicone rubber component B: softener: graphite = 5 ml: 5 ml: 2 ml: 0.6 g. The probe wedge angle has a significant effect on tissue injury. Compared to wedge angle 40° and 20°, maximum principal strain of 60° wedge angle was increased by 40.3% and 87.5%, respectively; compared with a relatively higher speed (500 μm/s), the maximum principle strain within the tissue induced by slow insertion speed (100 μm/s) was increased by 14.3%; insertion force required by probe with convex streamline was smaller than the force of traditional probe. Based on the experimental results, a novel neural probe that has a rounded tip covered by a biodegradable silk protein coating with convex streamline was proposed, which has both lower insertion and micromotion induced tissue injury. Conclusions: The established evaluation system has provided a simulation environment for testing brain tissue injury produced by various insertion conditions. At the same time, it eliminates the adverse effect of biological factors on tissue deformation during the experiment, improving the repeatability of measurement results. As a result, the evaluation system will provide support on novel neural probe design that can reduce the acute tissue injury during the implantation of the probe.« less
Direct detection of RNAs in living cells using peptide-inserted Renilla luciferase.
Andou, Takashi; Endoh, Tamaki; Mie, Masayasu; Kobatake, Eiry
2011-06-21
In this study, non-engineered RNAs were detected in living cells using bioluminescence. Two types of probe were utilized: a peptide inserted RLuc (PI-RLuc) probe and a split-RNA probe. Incorporation of the PI-RLuc and split-RNA probes enabled the direct detection of RNA introduced into living cells.
NASA Astrophysics Data System (ADS)
Morikawa, Takumi; Harashima, Takuya; Kino, Hisashi; Fukushima, Takafumi; Tanaka, Tetsu
2017-04-01
A less invasive Si optoneural probe with an embedded optical fiber was proposed and successfully fabricated. The diameter of the optical fiber was completely controlled by hydrogen fluoride etching, and the thinned optical fiber can propagate light without any leakage. This optical fiber was embedded in a trench formed inside a probe shank, which causes less damage to tissues. In addition, it was confirmed that the optical fiber embedded in the probe shank successfully irradiated light to optically stimulate gene transfected neurons. The electrochemical impedance of the probe did not change despite the light irradiation. Furthermore, probe insertion characteristics were evaluated in detail and less invasive insertion was clearly indicated for the Si optoneural probe with the embedded optical fiber compared with conventional optical neural probes. This neural probe with the embedded optical fiber can be used as a simple and easy tool for optogenetics and brain science.
ITE inhibits growth of human pulmonary artery endothelial cells.
Pang, Ling-Pin; Li, Yan; Zou, Qing-Yun; Zhou, Chi; Lei, Wei; Zheng, Jing; Huang, Shi-An
2017-10-01
Pulmonary arterial hypertension (PAH), a deadly disorder is associated with excessive growth of human pulmonary artery endothelial (HPAECs) and smooth muscle (HPASMCs) cells. Current therapies primarily aim at promoting vasodilation, which only ameliorates clinical symptoms without a cure. 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) is an endogenous aryl hydrocarbon receptor (AhR) ligand, and mediates many cellular function including cell growth. However, the roles of ITE in human lung endothelial cells remain elusive. Herein, we tested a hypothesis that ITE inhibits growth of human pulmonary artery endothelial cells via AhR. Immunohistochemistry was performed to localize AhR expression in human lung tissues. The crystal violet method and MTT assay were used to determine ITE's effects on growth of HPAECs. The AhR activation in HPAECs was confirmed using Western blotting and RT-qPCR. The role of AhR in ITE-affected proliferation of HPAECs was assessed using siRNA knockdown method followed by the crystal violet method. Immunohistochemistry revealed that AhR was present in human lung tissues, primarily in endothelial and smooth muscle cells of pulmonary veins and arteries, as well as in bronchial and alveolar sac epithelia. We also found that ITE dose- and time-dependently inhibited proliferation of HPAECs with a maximum inhibition of 83% at 20 µM after 6 days of treatment. ITE rapidly decreased AhR protein levels, while it increased mRNA levels of cytochrome P450 (CYP), family 1, member A1 (CYP1A1) and B1 (CYP1B1), indicating activation of the AhR/CYP1A1 and AhR/CYP1B1 pathways in HPAECs. The AhR siRNA significantly suppressed AhR protein expression, whereas it did not significantly alter ITE-inhibited growth of HPAECs. ITE suppresses growth of HPAECs independent of AhR, suggesting that ITE may play an important role in preventing excessive growth of lung endothelial cells.
Association of volume of patient encounters with residents' in-training examination performance.
McCoy, Christopher P; Stenerson, Matthew B; Halvorsen, Andrew J; Homme, Jason H; McDonald, Furman S
2013-08-01
Patient care and medical knowledge are Accreditation Council for Graduate Medical Education (ACGME) core competencies. The correlation between amount of patient contact and knowledge acquisition is not known. To determine if a correlation exists between the number of patient encounters and in-training exam (ITE) scores in internal medicine (IM) and pediatric residents at a large academic medical center. Retrospective cohort study Resident physicians at Mayo Clinic from July 2006 to June 2010 in IM (318 resident-years) and pediatrics (66 resident-years). We tabulated patient encounters through review of clinical notes in an electronic medical record during post graduate year (PGY)-1 and PGY-2. Using linear regression models, we investigated associations between ITE score and number of notes during the previous PGY, adjusted for previous ITE score, gender, medical school origin, and conference attendance. For IM, PGY-2 admission and consult encounters in the hospital and specialty clinics had a positive linear association with ITE-3 % score (β = 0.02; p = 0.004). For IM, PGY-1 conference attendance is positively associated with PGY-2 ITE performance. We did not detect a correlation between PGY-1 patient encounters and subsequent ITE scores for IM or pediatric residents. No association was found between IM PGY-2 ITE score and inpatient, outpatient, or total encounters in the first year of training. Resident continuity clinic and total encounters were not associated with change in PGY-3 ITE score. We identified a positive association between hospital and subspecialty encounters during the second year of IM training and subsequent ITE score, such that each additional 50 encounters were associated with an increase of 1 % correct in PGY-3 ITE score after controlling for previous ITE performance and continuity clinic encounters. We did not find a correlation for volume of encounters and medical knowledge for IM PGY-1 residents or the pediatric cohort.
2015-01-01
We have developed an improved tool for imaging acidic tumors by reporting the insertion of a transmembrane helix: the pHLIP-Fluorescence Insertion REporter (pHLIP-FIRE). In acidic tissues, such as tumors, peptides in the pHLIP family insert as α-helices across cell membranes. The cell-inserting end of the pHLIP-FIRE peptide has a fluorophore–fluorophore or fluorophore–quencher pair. A pair member is released by disulfide cleavage after insertion into the reducing environment inside a cell, resulting in dequenching of the probe. Thus, the fluorescence of the pHLIP-FIRE probe is enhanced upon cell-insertion in the targeted tissues but is suppressed elsewhere due to quenching. Targeting studies in mice bearing breast tumors show strong signaling by pHLIP-FIRE, with a contrast index of ∼17, demonstrating (i) direct imaging of pHLIP insertion and (ii) cargo translocation in vivo. Imaging and targeted cargo delivery should each have clinical applications. PMID:25184440
Machine Learning for Treatment Assignment: Improving Individualized Risk Attribution
Weiss, Jeremy; Kuusisto, Finn; Boyd, Kendrick; Liu, Jie; Page, David
2015-01-01
Clinical studies model the average treatment effect (ATE), but apply this population-level effect to future individuals. Due to recent developments of machine learning algorithms with useful statistical guarantees, we argue instead for modeling the individualized treatment effect (ITE), which has better applicability to new patients. We compare ATE-estimation using randomized and observational analysis methods against ITE-estimation using machine learning, and describe how the ITE theoretically generalizes to new population distributions, whereas the ATE may not. On a synthetic data set of statin use and myocardial infarction (MI), we show that a learned ITE model improves true ITE estimation and outperforms the ATE. We additionally argue that ITE models should be learned with a consistent, nonparametric algorithm from unweighted examples and show experiments in favor of our argument using our synthetic data model and a real data set of D-penicillamine use for primary biliary cirrhosis. PMID:26958271
Machine Learning for Treatment Assignment: Improving Individualized Risk Attribution.
Weiss, Jeremy; Kuusisto, Finn; Boyd, Kendrick; Liu, Jie; Page, David
2015-01-01
Clinical studies model the average treatment effect (ATE), but apply this population-level effect to future individuals. Due to recent developments of machine learning algorithms with useful statistical guarantees, we argue instead for modeling the individualized treatment effect (ITE), which has better applicability to new patients. We compare ATE-estimation using randomized and observational analysis methods against ITE-estimation using machine learning, and describe how the ITE theoretically generalizes to new population distributions, whereas the ATE may not. On a synthetic data set of statin use and myocardial infarction (MI), we show that a learned ITE model improves true ITE estimation and outperforms the ATE. We additionally argue that ITE models should be learned with a consistent, nonparametric algorithm from unweighted examples and show experiments in favor of our argument using our synthetic data model and a real data set of D-penicillamine use for primary biliary cirrhosis.
Hiller, Katherine; Franzen, Doug; Heitz, Corey; Emery, Matthew; Poznanski, Stacy
2015-11-01
There is great variation in the knowledge base of Emergency Medicine (EM) interns in July. The first objective knowledge assessment during residency does not occur until eight months later, in February, when the American Board of EM (ABEM) administers the in-training examination (ITE). In 2013, the National Board of Medical Examiners (NBME) released the EM Advanced Clinical Examination (EM-ACE), an assessment intended for fourth-year medical students. Administration of the EM-ACE to interns at the start of residency may provide an earlier opportunity to assess the new EM residents' knowledge base. The primary objective of this study was to determine the correlation of the NBME EM-ACE, given early in residency, with the EM ITE. Secondary objectives included determination of the correlation of the United States Medical Licensing Examination (USMLE) Step 1 or 2 scores with early intern EM-ACE and ITE scores and the effect, if any, of clinical EM experience on examination correlation. This was a multi-institutional, observational study. Entering EM interns at six residencies took the EM-ACE in July 2013 and the ABEM ITE in February 2014. We collected scores for the EM-ACE and ITE, age, gender, weeks of clinical EM experience in residency prior to the ITE, and USMLE Step 1 and 2 scores. Pearson's correlation and linear regression were performed. Sixty-two interns took the EM-ACE and the ITE. The Pearson's correlation coefficient between the ITE and the EM-ACE was 0.62. R-squared was 0.5 (adjusted 0.4). The coefficient of determination was 0.41 (95% CI [0.3-0.8]). For every increase of one in the scaled EM-ACE score, we observed a 0.4% increase in the EM in-training score. In a linear regression model using all available variables (EM-ACE, gender, age, clinical exposure to EM, and USMLE Step 1 and Step 2 scores), only the EM-ACE score was significantly associated with the ITE (p<0.05). We observed significant colinearity among the EM-ACE, ITE and USMLE scores. Gender, age and number of weeks of EM prior to the ITE had no effect on the relationship between EM-ACE and the ITE. Given early during intern year, the EM-ACE score showed positive correlation with ITE. Clinical EM experience prior to the in-training exam did not affect the correlation.
Hiller, Katherine; Franzen, Doug; Heitz, Corey; Emery, Matthew; Poznanski, Stacy
2015-01-01
Introduction There is great variation in the knowledge base of Emergency Medicine (EM) interns in July. The first objective knowledge assessment during residency does not occur until eight months later, in February, when the American Board of EM (ABEM) administers the in-training examination (ITE). In 2013, the National Board of Medical Examiners (NBME) released the EM Advanced Clinical Examination (EM-ACE), an assessment intended for fourth-year medical students. Administration of the EM-ACE to interns at the start of residency may provide an earlier opportunity to assess the new EM residents’ knowledge base. The primary objective of this study was to determine the correlation of the NBME EM-ACE, given early in residency, with the EM ITE. Secondary objectives included determination of the correlation of the United States Medical Licensing Examination (USMLE) Step 1 or 2 scores with early intern EM-ACE and ITE scores and the effect, if any, of clinical EM experience on examination correlation. Methods This was a multi-institutional, observational study. Entering EM interns at six residencies took the EM-ACE in July 2013 and the ABEM ITE in February 2014. We collected scores for the EM-ACE and ITE, age, gender, weeks of clinical EM experience in residency prior to the ITE, and USMLE Step 1 and 2 scores. Pearson’s correlation and linear regression were performed. Results Sixty-two interns took the EM-ACE and the ITE. The Pearson’s correlation coefficient between the ITE and the EM-ACE was 0.62. R-squared was 0.5 (adjusted 0.4). The coefficient of determination was 0.41 (95% CI [0.3–0.8]). For every increase of one in the scaled EM-ACE score, we observed a 0.4% increase in the EM in-training score. In a linear regression model using all available variables (EM-ACE, gender, age, clinical exposure to EM, and USMLE Step 1 and Step 2 scores), only the EM-ACE score was significantly associated with the ITE (p<0.05). We observed significant colinearity among the EM-ACE, ITE and USMLE scores. Gender, age and number of weeks of EM prior to the ITE had no effect on the relationship between EM-ACE and the ITE. Conclusion Given early during intern year, the EM-ACE score showed positive correlation with ITE. Clinical EM experience prior to the in-training exam did not affect the correlation. PMID:26594299
Ryan, James G; Barlas, David; Pollack, Simcha
2013-12-01
Medical knowledge (MK) in residents is commonly assessed by the in-training examination (ITE) and faculty evaluations of resident performance. We assessed the reliability of clinical evaluations of residents by faculty and the relationship between faculty assessments of resident performance and ITE scores. We conducted a cross-sectional, observational study at an academic emergency department with a postgraduate year (PGY)-1 to PGY-3 emergency medicine residency program, comparing summative, quarterly, faculty evaluation data for MK and overall clinical competency (OC) with annual ITE scores, accounting for PGY level. We also assessed the reliability of faculty evaluations using a random effects, intraclass correlation analysis. We analyzed data for 59 emergency medicine residents during a 6-year period. Faculty evaluations of MK and OC were highly reliable (κ = 0.99) and remained reliable after stratification by year of training (mean κ = 0.68-0.84). Assessments of resident performance (MK and OC) and the ITE increased with PGY level. The MK and OC results had high correlations with PGY level, and ITE scores correlated moderately with PGY. The OC and MK results had a moderate correlation with ITE score. When residents were grouped by PGY level, there was no significant correlation between MK as assessed by the faculty and the ITE score. Resident clinical performance and ITE scores both increase with resident PGY level, but ITE scores do not predict resident clinical performance compared with peers at their PGY level.
Ryan, James G.; Barlas, David; Pollack, Simcha
2013-01-01
Background Medical knowledge (MK) in residents is commonly assessed by the in-training examination (ITE) and faculty evaluations of resident performance. Objective We assessed the reliability of clinical evaluations of residents by faculty and the relationship between faculty assessments of resident performance and ITE scores. Methods We conducted a cross-sectional, observational study at an academic emergency department with a postgraduate year (PGY)-1 to PGY-3 emergency medicine residency program, comparing summative, quarterly, faculty evaluation data for MK and overall clinical competency (OC) with annual ITE scores, accounting for PGY level. We also assessed the reliability of faculty evaluations using a random effects, intraclass correlation analysis. Results We analyzed data for 59 emergency medicine residents during a 6-year period. Faculty evaluations of MK and OC were highly reliable (κ = 0.99) and remained reliable after stratification by year of training (mean κ = 0.68–0.84). Assessments of resident performance (MK and OC) and the ITE increased with PGY level. The MK and OC results had high correlations with PGY level, and ITE scores correlated moderately with PGY. The OC and MK results had a moderate correlation with ITE score. When residents were grouped by PGY level, there was no significant correlation between MK as assessed by the faculty and the ITE score. Conclusions Resident clinical performance and ITE scores both increase with resident PGY level, but ITE scores do not predict resident clinical performance compared with peers at their PGY level. PMID:24455005
The use of observational diaries in in-training evaluation: student perceptions.
Govaerts, Marjan J B; van der Vleuten, Cees P M; Schuwirth, Lambert W T; Muijtjens, Arno M M
2005-08-01
In health science education clinical clerkships serve the twofold purpose of guiding student learning and assessment of performance. Evidently, both formative and summative assessment procedures are needed in clerkship assessment. In-training evaluation (ITE) has the potential to serve both assessment functions. Implementation of effective ITE, however, has been shown to be problematic, partly because integration of assessment functions may have negative consequences for teaching and learning. This study investigates student perceptions of the impact of an integrated assessment approach, seeking to refine criteria for effective ITE. In the curriculum of Maastricht Midwifery School (MMS), clerkship assessment is based on ITE serving both assessment functions. The ITE model is based on principles of extensive work sampling, and frequent documentation of performance. A focus group technique was used to explore student perceptions on the impact of the ITE approach on student learning and supervisor teaching behaviour, and on the usefulness of information for decision making. Results indicate that the assessment approach is effective in guidance of student learning. Furthermore, students consider the frequent performance documentation essential in clerkship grading. Acceptance and effectivity of ITE requires a learning environment which is safe and respectful. Transparency of assessment processes is the key to success. Suggestions for improvement focus on variation in evaluation formats, improvement of feedback (narrative, complete) and student involvement in assessment. ITE can fulfill both its formative and summative purposes when some crucial conditions are taken into account. Careful training of both supervisors and students in the use of ITE for student learning and performance measurement is essential.
Audience Response System Facilitates Prediction of Scores on In-Training Examination.
Shah, Kaushal H; Jordan, Jaime; Jahnes, Katherine; Lisbon, David P; Lutfy-Clayton, Lucienne; Wei, Grant; Winkel, Gary; Santen, Sally A
2017-04-01
Audience response systems (ARS) are increasingly popular; however, their contribution to education is not completely clear. Our study found that scores from review quizzes delivered by an ARS correlate with in-training exam (ITE) scores and are viewed positively by residents. This information may be useful in identifying poor performers early so that targeted educational interventions can be made. The objective was to determine if scores on review quizzes delivered by an ARS correlate with ITE scores and to obtain participant feedback on use of the ARS for ITE preparation. This was a prospective observational study of emergency medicine (EM) residents at six accredited EM residency programs. Subjects included residents who had taken previous ITEs. Subjects participated in bimonthly review sessions using an ARS. Twelve review quizzes were administered, each consisting of 10 multiple-choice questions. After the ITE, subjects completed an attitudinal survey consisting of six Likert-scale items and one "yes/no" item. We used a mixed linear model to analyze the data, accounting for prior 2012 ITE scores and nesting due to institution. Among 192 participants, 135 (70.3%) completed the ITE in both 2012 and 2013; we analyzed their data for the first objective. Results from the mixed linear model indicate that the total mean score on the review quizzes was a significant [t(127) = 6.68; p < 0.001] predictor of the 2013 ITE after controlling for the 2012 ITE score. One hundred forty-six (76.0%) participants completed the attitudinal survey; 96% of respondents stated that they would like ARS to be used more often in resident education. Respondents felt the sessions aided in learning (mean 7.7/10), assisted in preparation for the ITE (mean 6.7/10), and helped identify content areas of weakness (mean 7.6/10). Our results suggest that scores from review quizzes delivered by an audience response system correlate with in-training exam scores and is viewed positively by residents.
Varner, Erika L; Leong, Chi Leng; Jaquins-Gerstl, Andrea; Nesbitt, Kathryn M; Boutelle, Martyn G; Michael, Adrian C
2017-08-16
Microdialysis is well established in chemical neuroscience as a mainstay technology for real time intracranial chemical monitoring in both animal models and human patients. Evidence shows that microdialysis can be enhanced by mitigating the penetration injury caused during the insertion of microdialysis probes into brain tissue. Herein, we show that retrodialysis of dexamethasone in the rat cortex enhances the microdialysis detection of K + and glucose transients induced by spreading depolarization. Without dexamethasone, quantification of glucose transients was unreliable by 5 days after probe insertion. With dexamethasone, robust K + and glucose transients were readily quantified at 2 h, 5 days, and 10 days after probe insertion. The amplitudes of the K + transients declined day-to-day following probe insertion, and the amplitudes of the glucose transients exhibited a decreasing trend that did not reach statistical significance. Immunohistochemistry and fluorescence microscopy confirm that dexamethasone is highly effective at preserving a healthy probe-brain interface for at least 10 days even though retrodialysis of dexamethasone ceased after 5 days.
Hubbell, Joel M.; Sisson, James B.
2005-07-26
A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.
Innovative SPM Probes for Energy-Storage Science: MWCNT-Nanopipettes to Nanobattery Probes
NASA Astrophysics Data System (ADS)
Larson, Jonathan; Talin, Alec; Pearse, Alexander; Kozen, Alexander; Reutt-Robey, Janice
As energy-storage materials and designs continue to advance, new tools are needed to direct and explore ion insertion/de-insertion at well-defined battery materials interfaces. Scanned probe tips, assembled from actual energy-storage materials, permit SPM measures of local cathode-anode (tip-sample) interactions, including ion transfer. We present examples of ``cathode'' MWCNT-terminated STM probe tips interacting with Li(s)/Si(111) anode substrates. The MWCNT tip functions as both SPM probe and Li-nanopipette,[1] for controlled transport and manipulation of Li. Local field conditions for lithium ionization and transfer are determined and compared to electrostatic models. Additional lithium metallic and oxide tips have been prepared by thin film deposition on conventional W tips, the latter of which effectively functions as a nanobattery. We demonstrate use of these novel probe materials in the local lithiation of low-index Si anode interfaces, probing local barriers for lithium insertion. Prospects and limitations of these novel SPM probes will be discussed. U.S. Department of Energy Award Number DESC0001160.
Brattström, A; Schapowal, A; Kamal, M A; Maillet, I; Ryffel, B; Moser, R
2010-07-01
The herbal Isatis tinctoria extract (ITE) inhibits the inducible isoform of cyclooxygenase (COX-2) as well as lipoxygenase (5-LOX) and therefore possesses anti-inflammatory properties. The extract might also be useful in allergic airway diseases which are characterized by chronic inflammation. ITE obtained from leaves by supercritical carbon dioxide extraction was investigated in ovalbumin (OVA) immunised BALB/c mice given intranasally together with antigen challenge in the murine model of allergic airway disease (asthma) with the analysis of the inflammatory and immune parameters in the lung. ITE given with the antigen challenge inhibited in a dose related manner the allergic response. ITE diminished airway hyperresponsiveness (AHR) and eosinophil recruitment into the bronchoalveolar lavage (BAL) fluid upon allergen challenge, but had no effect in the saline control mice. Eosinophil recruitment was further assessed in the lung by eosinophil peroxidase (EPO) activity at a dose of 30 microg ITE per mouse. Microscopic investigations revealed less inflammation, eosinophil recruitment and mucus hyperproduction in the lung in a dose related manner. Diminution of AHR and inflammation was associated with reduced IL-4, IL-5, and RANTES production in the BAL fluid at the 30 microg ITE dose, while OVA specific IgE and eotaxin serum levels remained unchanged. ITE, which has been reported inhibiting COX-2 and 5-LOX, reduced allergic airway inflammation and AHR by inhibiting the production of the Th2 cytokines IL-4 and IL-5, and RANTES. (c) 2009 Elsevier GmbH. All rights reserved.
Withiam-Leitch, Matthew; Olawaiye, Alexander
2008-01-01
The Accreditation Council on Graduate Medical Education (ACGME) Outcomes Project has endorsed the in-training examination (ITE) as an example of a multiple-choice question examination that is a valid measure of a resident's attainment of medical knowledge. An outcome measure for performance on the ITE would be the subsequent performance on the board certification examination. However, there are few reports that attempt to correlate a resident's performance on the ITE to subsequent performance on the board certification examination. The Council on Resident Education in Obstetrics and Gynecology (CREOG) has administered the ITE annually since 1970. This study tested the hypothesis that the CREOG-ITE score is a valid assessment tool to predict performance on the American Board of Obstetrics and Gynecology (ABOG) written examination. CREOG-ITE and ABOG written board examination results were collected for 69 resident graduates between the years 1998 and 2005. Logistic regression and receiver operating characteristic analyses were used to estimate the relationship between a resident's score on the CREOG-ITE and subsequent performance on the ABOG written examination. Fifty-seven resident graduates passed (82.6%) and 12 graduates failed (17.4%) the ABOG written examination. The correlation between the CREOG-ITE overall score and performance on the ABOG examination was weak (correlation coefficient =.38, p =.001). Receiver operating characteristic analysis for the CREOG-ITE overall scores and the probability of passing or failing the ABOG examination revealed moderate accuracy (area under the curve = 0.77, 95% CI = 0.62-0.92) with a CREOG-ITE score of 187.5 yielding the best trade-off between specificity (0.79) and sensitivity (0.75). At the cutoff value of 187.5 there was a weak positive predictive value of 43% (i.e., 43% of residents with a score less than 187.5 will fail the ABOG exam) and a strong negative predictive value of 94% (i.e., 94% of the residents with a score above 187.5 will pass the ABOG exam). Logistic regression analysis also revealed a statistically significant relationship between the CREOG-ITE overall score and performance on the ABOG written examination (p = .003). Similar to other specialties, resident performance on the CREOG-ITE is a weak assessment tool to predict the probability of a resident failing the ABOG written examination. Our study highlights the need, in the spirit of the ACGME Outcome Project, for residency and board specialty organizations to coordinate efforts to develop more reliable and correlative measures of a resident's medical knowledge and ability to pass the boards.
Spectral dependence of the main parameters of ITE silicon avalanche photodiodes
NASA Astrophysics Data System (ADS)
Wegrzecka, Iwona; Grynglas, Maria; Wegrzecki, Maciej
2001-08-01
New applications for avalanche photodiodes (APDs) as in systems using visible radiation, have prompted the need for the evaluation of detection properties of ITE APDs in the 400 divided by 700 nm spectral range. The paper presents the method and result of studies on the spectral dependence of the gain, dark and noise currents, sensitivity and excess noise factor of ITE APDs. The studies have shown that ITE APDs optimized for the near IR radiation can be effectively applied in the detection of radiation above the 500 nm wavelength.
Kempainen, Robert R; Hess, Brian J; Addrizzo-Harris, Doreen J; Schaad, Douglas C; Scott, Craig S; Carlin, Brian W; Shaw, Robert C; Duhigg, Lauren; Lipner, Rebecca S
2016-04-01
Most trainees in combined pulmonary and critical care medicine fellowship programs complete in-service training examinations (ITEs) that test knowledge in both disciplines. Whether ITE scores predict performance on the American Board of Internal Medicine Pulmonary Disease Certification Examination and Critical Care Medicine Certification Examination is unknown. To determine whether pulmonary and critical care medicine ITE scores predict performance on subspecialty board certification examinations independently of trainee demographics, program director competency ratings, fellowship program characteristics, and prior medical knowledge assessments. First- and second-year fellows who were enrolled in the study between 2008 and 2012 completed a questionnaire encompassing demographics and fellowship training characteristics. These data and ITE scores were matched to fellows' subsequent scores on subspecialty certification examinations, program director ratings, and previous scores on their American Board of Internal Medicine Internal Medicine Certification Examination. Multiple linear regression and logistic regression were used to identify independent predictors of subspecialty certification examination scores and likelihood of passing the examinations, respectively. Of eligible fellows, 82.4% enrolled in the study. The ITE score for second-year fellows was matched to their certification examination scores, which yielded 1,484 physicians for pulmonary disease and 1,331 for critical care medicine. Second-year fellows' ITE scores (β = 0.24, P < 0.001) and Internal Medicine Certification Examination scores (β = 0.49, P < 0.001) were the strongest predictors of Pulmonary Disease Certification Examination scores, and were the only significant predictors of passing the examination (ITE odds ratio, 1.12 [95% confidence interval, 1.07-1.16]; Internal Medicine Certification Examination odds ratio, 1.01 [95% confidence interval, 1.01-1.02]). Similar results were obtained for predicting Critical Care Medicine Certification Examination scores and for passing the examination. The predictive value of ITE scores among first-year fellows on the subspecialty certification examinations was comparable to second-year fellows' ITE scores. The Pulmonary and Critical Care Medicine ITE score is an independent, and stronger, predictor of subspecialty certification examination performance than fellow demographics, program director competency ratings, and fellowship characteristics. These findings support the use of the ITE to identify the learning needs of fellows as they work toward subspecialty board certification.
Probe insertion apparatus with inflatable seal
NASA Technical Reports Server (NTRS)
Trimarchi, Paul A. (Inventor)
1990-01-01
A sealing apparatus is disclosed for inserting a probe into a pressure vessel having an elongated opening includes a pair of resiliently deformable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in pressure vessel.
Effect of ITE and nozzle exit cone erosion on specific impulse of solid rocket motors
NASA Astrophysics Data System (ADS)
Smith-Kent, Randall; Ridder, Jeffrey P.; Loh, Hai-Tien; Abel, Ralph
1993-06-01
Specific impulse loss due to the use of a slowly eroding integral throat entrance, or a throat insert, with a faster eroding nozzle exit cone is studied. It is suggested that an oblique shock wave produced by step-off erosion results in loss of specific impulse. This is studied by use of a shock capturing CFD method. The shock loss predictions for first-stage Peacekeeper and Castor 25 motors are found to match the trends of the test data. This work suggests that a loss mechanism, previously unaccounted, should be considered in the specific impulse prediction procedure for nozzles with step-off exit cone erosion.
Nugent, Lindsey F; Shi, Guangpu; Vistica, Barbara P; Ogbeifun, Osato; Hinshaw, Samuel J H; Gery, Igal
2013-11-13
Ligands for aryl hydrocarbon receptor (AHR), such as dioxins, are highly toxic. One such ligand, TCDD, was found to exert potent immunosuppressive capacities in mice developing pathogenic autoimmune processes, including EAU, but its toxicity makes it unusable for humans. A recently identified endogenous AHR ligand, ITE, is also immunosuppressive, but is nontoxic and could therefore be useful for therapy in humans. Here, we tested ITE for its capacity to inhibit EAU and related immune responses. EAU was induced in B10.A mice by immunization with interphotoreceptor retinoid-binding protein (IRBP; 40 μg) in CFA. Treatment with ITE was by daily intraperitoneal injection of 0.2 mg. Disease severity was assessed by both fundoscopy and histological examination. Draining lymph node cells were tested for proliferation by thymidine uptake and for cytokine production and release by ELISA. In addition, the intracellular expression of cytokines and Foxp3 was determined by flow cytometry. Serum antibodies were measured by ELISA. Treatment with ITE efficiently inhibited the development of EAU in mice, as well as the cellular immune responses against IRBP and PPD. ITE treatment inhibited the expansion of both Th1 and Th17 subpopulations, as well as their release of the signature cytokines, IFN-gamma and IL-17. The treatment moderately increased, however, the proportion of Foxp3 expressing T-regulatory cells. Antibody production was not affected by the treatment. ITE, an endogenous AHR ligand, efficiently inhibits EAU development and related cellular immune responses. Being nontoxic, ITE may be considered for treatment of pathogenic immunity in humans.
Nugent, Lindsey F.; Shi, Guangpu; Vistica, Barbara P.; Ogbeifun, Osato; Hinshaw, Samuel J. H.; Gery, Igal
2013-01-01
Purpose. Ligands for aryl hydrocarbon receptor (AHR), such as dioxins, are highly toxic. One such ligand, TCDD, was found to exert potent immunosuppressive capacities in mice developing pathogenic autoimmune processes, including EAU, but its toxicity makes it unusable for humans. A recently identified endogenous AHR ligand, ITE, is also immunosuppressive, but is nontoxic and could therefore be useful for therapy in humans. Here, we tested ITE for its capacity to inhibit EAU and related immune responses. Methods. EAU was induced in B10.A mice by immunization with interphotoreceptor retinoid-binding protein (IRBP; 40 μg) in CFA. Treatment with ITE was by daily intraperitoneal injection of 0.2 mg. Disease severity was assessed by both fundoscopy and histological examination. Draining lymph node cells were tested for proliferation by thymidine uptake and for cytokine production and release by ELISA. In addition, the intracellular expression of cytokines and Foxp3 was determined by flow cytometry. Serum antibodies were measured by ELISA. Results. Treatment with ITE efficiently inhibited the development of EAU in mice, as well as the cellular immune responses against IRBP and PPD. ITE treatment inhibited the expansion of both Th1 and Th17 subpopulations, as well as their release of the signature cytokines, IFN-gamma and IL-17. The treatment moderately increased, however, the proportion of Foxp3 expressing T-regulatory cells. Antibody production was not affected by the treatment. Conclusions. ITE, an endogenous AHR ligand, efficiently inhibits EAU development and related cellular immune responses. Being nontoxic, ITE may be considered for treatment of pathogenic immunity in humans. PMID:24150760
Evaluating Crustal Contamination Effects on the Lithophile Trace Element Budget of Shergottites
NASA Technical Reports Server (NTRS)
Brandon, A. D.; Ferdous, J.; Peslier, A. H.
2017-01-01
The origin of the incompatible trace element (ITE) enriched compositions of shergottites has been a point of contention for decades [1-2]. Two scenarios have been proposed, the first is that enriched shergottite compositions reflect an ITE-enriched mantle source, whereas in the second, the ITE enrichment reflects crustal contamination of mantle-derived parent magmas. Evidence supporting the first scenario is that the ITE-enriched shergottite compositions are consistent with the outcomes of magma ocean crystallization [3], and that Os-Nd isotope relationships for shergottites cannot be explained by realistic crustal contamination models [4]. In contrast, Cl and S isotopes are consistent with shergottite magmas interacting with Mars crust [5,6], and ITE-enriched olivine-hosted melt inclusions and interstitial glass are found in depleted shergottite Yamato 980459 [7]. These findings indicate that some level of crustal interaction occurred but the question of whether ITE-enrichments in some bulk shergottites reflect crustal contamination remains open. Recently, a Mars crustal breccia meteorite has been found, NWA 7034 and its paired stones, that is our best analogue to an average of Mars ancient crust [8-10]. This allows for better constraints on crustal contamination of shergottite magmas. We modeled magma-crust mixing and assimilation-fractional crystallization (AFC) using ITE-depleted shergottite compositions and bulk NWA 7034 and its clasts as end-members. The results of these models indicate that crustal contamination can only explain the ITE-enriched compositions of some bulk shergottites under unusual circumstances. It is thus likely that the shergottite range of compositions reflects primarily mantle sources.
CREOG In-Training Examination Results: Contemporary Use to Predict ABOG Written Examination Outcomes
Lingenfelter, Brandon M.; Jiang, Xuezhi; Schnatz, Peter F.; O'Sullivan, David M.; Minassian, Shahab S.; Forstein, David A.
2016-01-01
Background The in-training examination (ITE) offers formative assessments of residents' developing medical knowledge. Identification of an ITE performance level associated with success on the specialty board examination allows identification of “at risk” residents. Objective This study sought to identify a threshold score for obstetrics and gynecology residents' performance on the Council on Resident Education in Obstetrics and Gynecology (CREOG) ITE that predicts successful performance on the American Board of Obstetrics and Gynecology (ABOG) written examination. Methods We analyzed ITE and ABOG results of 80 residents who completed 4 years of CREOG ITEs at 2 institutions between 2002 and 2012. We assessed the level of performance associated with successful performance on the ABOG written examination. Results Data analyzed included scores for 71 of 80 residents (89%), with an overall pass rate of 82%. A postgraduate year (PGY) 4 score of 200 on the CREOG ITE or twice in any of the PGY training years was associated with a 100% ABOG pass rate. Scoring ≥ 205 in any PGY also was associated with a 100% pass rate. Residents who did not attain a score of 200 had a 35% to 45% chance of failing the ABOG written examination, depending on the PGY of the ITE performance. Conclusions Our findings suggest that a CREOG ITE score of at least 200 twice, or as a PGY-4, offers assurance of successful performance on the ABOG examination. Scores lower than this threshold may be used to identify “at risk” residents for added learning and provide program elements in need of improvement. PMID:27413437
Lingenfelter, Brandon M; Jiang, Xuezhi; Schnatz, Peter F; O'Sullivan, David M; Minassian, Shahab S; Forstein, David A
2016-07-01
The in-training examination (ITE) offers formative assessments of residents' developing medical knowledge. Identification of an ITE performance level associated with success on the specialty board examination allows identification of "at risk" residents. This study sought to identify a threshold score for obstetrics and gynecology residents' performance on the Council on Resident Education in Obstetrics and Gynecology (CREOG) ITE that predicts successful performance on the American Board of Obstetrics and Gynecology (ABOG) written examination. We analyzed ITE and ABOG results of 80 residents who completed 4 years of CREOG ITEs at 2 institutions between 2002 and 2012. We assessed the level of performance associated with successful performance on the ABOG written examination. Data analyzed included scores for 71 of 80 residents (89%), with an overall pass rate of 82%. A postgraduate year (PGY) 4 score of 200 on the CREOG ITE or twice in any of the PGY training years was associated with a 100% ABOG pass rate. Scoring ≥ 205 in any PGY also was associated with a 100% pass rate. Residents who did not attain a score of 200 had a 35% to 45% chance of failing the ABOG written examination, depending on the PGY of the ITE performance. Our findings suggest that a CREOG ITE score of at least 200 twice, or as a PGY-4, offers assurance of successful performance on the ABOG examination. Scores lower than this threshold may be used to identify "at risk" residents for added learning and provide program elements in need of improvement.
Effect of Probe Tube Insertion Depth on Spectral Measures of Speech
Caldwell, Marc; Souza, Pamela E.; Tremblay, Kelly L.
2006-01-01
This study investigated how depth variations in the tip of the probe tube affected spectral measures of speech recorded in the external ear canal. Consonant-vowel nonsense syllables were recorded with a probe tube microphone system in 10 adult participants with normal middle ear function. Recordings were made with the probe tube tip placed 1 mm, 5 mm, and 10 mm beyond the medial tip of a custom earmold. The effect of probe depth was evaluated on spectral levels (one-third octave and one-twelfth octave band). Extending the probe tube 10 mm past the medial tip of the earmold gave the most accurate results, with relatively lower sound levels for either the 1-mm or 5-mm insertion depth. In general, the effect of insertion depth was minimal at frequencies below 3 to 4 kHz, although this varied with the specific phoneme and the width of the analysis bands. The authors found no significant difference between 1- and 5-mm insertion depths, suggesting that as long as the tip of the probe tube is sufficiently close to the tympanic membrane to capture the highest frequency of interest, it makes little difference if it is less than 5 mm beyond the earmold tip. PMID:16959735
NASA Astrophysics Data System (ADS)
Theiler, C.; Diallo, A.; Fasoli, A.; Furno, I.; Labit, B.; Podestà, M.; Poli, F. M.; Ricci, P.
2008-04-01
Intermittent cross-field particle transport events (ITEs) are studied in the basic toroidal device TORPEX [TORoidal Plasma EXperiment, A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], with focus on the role of the density gradient. ITEs are due to the intermittent radial elongation of an interchange mode. The elongating positive wave crests can break apart and form blobs. This is not necessary, however, for plasma particles to be convected a considerable distance across the magnetic field lines. Conditionally sampled data reveal two different scenarios leading to ITEs. In the first case, the interchange mode grows radially from a slab-like density profile and leads to the ITE. A novel analysis technique reveals a monotonic dependence between the vertically averaged inverse radial density scale length and the probability for a subsequent ITE. In the second case, the mode is already observed before the start of the ITE. It does not elongate radially in a first stage, but at a later time. It is shown that this elongation is preceded by a steepening of the density profile as well.
Indik, Julia H; Duhigg, Lauren M; McDonald, Furman S; Lipner, Rebecca S; Rubright, Jonathan D; Haist, Steven A; Botkin, Naomi F; Kuvin, Jeffrey T
2017-06-13
The American College of Cardiology In-Training Exam (ACC-ITE) is incorporated into most U.S. training programs, but its relationship to performance on the American Board of Internal Medicine Cardiovascular Disease (ABIM CVD) Certification Examination is unknown. ACC-ITE scores from third-year fellows from 2011 to 2014 (n = 1,918) were examined. Covariates for regression analyses included sex, age, medical school country, U.S. Medical Licensing Examination Step, and ABIM Internal Medicine Certification Examination scores. A secondary analysis examined fellows (n = 511) who took the ACC-ITE in the first and third years. ACC-ITE scores were the strongest predictor of ABIM CVD scores (p < 0.0001), and the most significant predictor of passing (p < 0.0001). The change in ACC-ITE scores from first to third year was a strong predictor of the ABIM CVD score (p < 0.001). The ACC-ITE is strongly associated with performance on the ABIM CVD Certification Examination. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Erti, A. C.
1995-01-01
Submaximal exercise (61+3% peak VO2) metabolism was measured before (AC day-2) and on bed rest day 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N=5) control, and isotonic exercise (ITE, N=7)and isokinetic exercise (IKE, N=7) training groups. Training was conducting supine for two 30-min periods/d for 6 d/wk: ITE was 60-90% peak VO2: IKE was peak knee flexion-extension at 100 deg/s. Supine submaximal exercise 102 decreased significantly (*p<0.05) by 10.3%, with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output (Q) change of -14.5%* (ITE) and -203%* (IKE), but different from change in peak VO2 (+1.4% with ITE and - 10.2%, with IKE) and plasma volume of -3.7% (ITE) and - 18.0% * (IKE). Thus, reduction of submaximal V02 during prolonged bed rest appears to respond to submaximal Q but is not related to change in peak VO2 or plasma volume.
Lohr, Kristine M; Clauser, Amanda; Hess, Brian J; Gelber, Allan C; Valeriano-Marcet, Joanne; Lipner, Rebecca S; Haist, Steven A; Hawley, Janine L; Zirkle, Sarah; Bolster, Marcy B
2015-11-01
The American College of Rheumatology (ACR) Adult Rheumatology In-Training Examination (ITE) is a feedback tool designed to identify strengths and weaknesses in the content knowledge of individual fellows-in-training and the training program curricula. We determined whether scores on the ACR ITE, as well as scores on other major standardized medical examinations and competency-based ratings, could be used to predict performance on the American Board of Internal Medicine (ABIM) Rheumatology Certification Examination. Between 2008 and 2012, 629 second-year fellows took the ACR ITE. Bivariate correlation analyses of assessment scores and multiple linear regression analyses were used to determine whether ABIM Rheumatology Certification Examination scores could be predicted on the basis of ACR ITE scores, United States Medical Licensing Examination scores, ABIM Internal Medicine Certification Examination scores, fellowship directors' ratings of overall clinical competency, and demographic variables. Logistic regression was used to evaluate whether these assessments were predictive of a passing outcome on the Rheumatology Certification Examination. In the initial linear model, the strongest predictors of the Rheumatology Certification Examination score were the second-year fellows' ACR ITE scores (β = 0.438) and ABIM Internal Medicine Certification Examination scores (β = 0.273). Using a stepwise model, the strongest predictors of higher scores on the Rheumatology Certification Examination were second-year fellows' ACR ITE scores (β = 0.449) and ABIM Internal Medicine Certification Examination scores (β = 0.276). Based on the findings of logistic regression analysis, ACR ITE performance was predictive of a pass/fail outcome on the Rheumatology Certification Examination (odds ratio 1.016 [95% confidence interval 1.011-1.021]). The predictive value of the ACR ITE score with regard to predicting performance on the Rheumatology Certification Examination supports use of the Adult Rheumatology ITE as a valid feedback tool during fellowship training. © 2015, American College of Rheumatology.
The Aryl Hydrocarbon Receptor Ligand ITE Inhibits TGFβ1-Induced Human Myofibroblast Differentiation
Lehmann, Geniece M.; Xi, Xia; Kulkarni, Ajit A.; Olsen, Keith C.; Pollock, Stephen J.; Baglole, Carolyn J.; Gupta, Shikha; Casey, Ann E.; Huxlin, Krystel R.; Sime, Patricia J.; Feldon, Steven E.; Phipps, Richard P.
2011-01-01
Fibrosis can occur in any human tissue when the normal wound healing response is amplified. Such amplification results in fibroblast proliferation, myofibroblast differentiation, and excessive extracellular matrix deposition. Occurrence of these sequelae in organs such as the eye or lung can result in severe consequences to health. Unfortunately, medical treatment of fibrosis is limited by a lack of safe and effective therapies. These therapies may be developed by identifying agents that inhibit critical steps in fibrotic progression; one such step is myofibroblast differentiation triggered by transforming growth factor-β1 (TGFβ1). In this study, we demonstrate that TGFβ1-induced myofibroblast differentiation is blocked in human fibroblasts by a candidate endogenous aryl hydrocarbon receptor (AhR) ligand 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). Our data show that ITE disrupts TGFβ1 signaling by inhibiting the nuclear translocation of Smad2/3/4. Although ITE functions as an AhR agonist, and biologically persistent AhR agonists, such as 2,3,7,8-tetrachlorodibenzo-p-dioxin, cause severe toxic effects, ITE exhibits no toxicity. Interestingly, ITE effectively inhibits TGFβ1-driven myofibroblast differentiation in AhR−/− fibroblasts: Its ability to inhibit TGFβ1 signaling is AhR independent. As supported by the results of this study, the small molecule ITE inhibits myofibroblast differentiation and may be useful clinically as an antiscarring agent. PMID:21406171
Towards Evidence-Based Initial Teacher Education in Singapore: A Review of Current Literature
ERIC Educational Resources Information Center
Low, Ee-Ling; Hui, Chenri; Taylor, Peter G.; Ng, Pak Tee
2012-01-01
Initial teacher education (ITE) in Singapore is shifting towards evidence-based practice. Despite a clear policy orientation, ITE in Singapore has not yet produced the evidence base that it is anticipating. This paper presents an analytical review of previous research into ITE in Singapore and makes comparisons to the larger international context.…
Mathematics Education ITE Students Examining the Value of Digital Learning Objects
ERIC Educational Resources Information Center
Hawera Ngarewa; Wright, Noeline; Sharma, Sashi
2017-01-01
One issue in mathematics initial teacher education (ITE) is how to best support students to use digital technologies (DTs) to enhance their teaching of mathematics. While most ITE students are probably using DTs on a daily basis for personal use, they are often unfamiliar with using them for educative purposes in New Zealand primary school…
Navigating conjugated polymer actuated neural probes in a brain phantom
NASA Astrophysics Data System (ADS)
Daneshvar, Eugene D.; Kipke, Daryl; Smela, Elisabeth
2012-04-01
Neural probe insertion methods have a direct impact on the longevity of the device in the brain. Initial tissue and vascular damage caused by the probe entering the brain triggers a chronic tissue response that is known to attenuate neural recordings and ultimately encapsulate the probes. Smaller devices have been found to evoke reduced inflammatory response. One way to record from undamaged neural networks may be to position the electrode sites away from the probe. To investigate this approach, we are developing probes with controllably movable electrode projections, which would move outside of the zone that is damaged by the insertion of the larger probe. The objective of this study was to test the capability of conjugated polymer bilayer actuators to actuate neural electrode projections from a probe shank into a transparent brain phantom. Parylene neural probe devices, having five electrode projections with actuating segments and with varying widths (50 - 250 μm) and lengths (200 - 1000 μm) were fabricated. The electroactive polymer polypyrrole (PPy) was used to bend or flatten the projections. The devices were inserted into the brain phantom using an electronic microdrive while simultaneously activating the actuators. Deflections were quantified based on video images. The electrode projections were successfully controlled to either remain flat or to actuate out-of-plane and into the brain phantom during insertion. The projection width had a significant effect on their ability to deflect within the phantom, with thinner probes deflecting but not the wider ones. Thus, small integrated conjugated polymer actuators may enable multiple neuro-experiments and applications not possible before.
Vacuum-actuated percutaneous insertion/implantation tool for flexible neural probes and interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Heeral; Bennett, William J.; Pannu, Satinderpall S.
A flexible device insertion tool including an elongated stiffener with one or more suction ports, and a vacuum connector for interfacing the stiffener to a vacuum source, for attaching the flexible device such as a flexible neural probe to the stiffener during insertion by a suction force exerted through the suction ports to, and to release the flexible device by removing the suction force.
Henry, Ellen C; Welle, Stephen L; Gasiewicz, Thomas A
2010-03-01
The aryl hydrocarbon receptor (AhR), a ligand-dependent transcription factor, mediates toxicity of several classes of xenobiotics and also has important physiological roles in differentiation, reproduction, and immunity, although the endogenous ligand(s) mediating these functions is/are as yet unidentified. One candidate endogenous ligand, 2-(1'H-indolo-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), is a potent AhR agonist in vitro, activates the murine AhR in vivo, but does not induce toxicity. We hypothesized that ITE and the toxic ligand, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), may modify transcription of different sets of genes to account for their different toxicity. To test this hypothesis, primary mouse lung fibroblasts were exposed to 0.5muM ITE, 0.2nM TCDD, or vehicle for 4 h, and total gene expression was evaluated using microarrays. After this short-term and low-dose treatment, several hundred genes were changed significantly, and the response to ITE and TCDD was remarkably similar, both qualitatively and quantitatively. Induced gene sets included the expected battery of AhR-dependent xenobiotic-metabolizing enzymes, as well as several sets that reflect the inflammatory role of lung fibroblasts. Real time quantitative RT-qPCR assay of several selected genes confirmed these microarray data and further suggested that there may be kinetic differences in expression between ligands. These data suggest that ITE and TCDD elicit an analogous change in AhR conformation such that the initial transcription response is the same. Furthermore, if the difference in toxicity between TCDD and ITE is mediated by differences in gene expression, then it is likely that secondary changes enabled by the persistent TCDD, but not by the shorter lived ITE, are responsible.
Abron, Jessicca D; Singh, Narendra P; Mishra, Manoj K; Price, Robert L; Nagarkatti, Mitzi; Nagarkatti, Prakash S; Singh, Udai P
2018-04-19
Inflammatory bowel disease (IBD) is a chronic intestinal inflammatory condition that affects millions of people with high morbidity and health-care cost. The precise etiology of IBD is unknown, but clear evidence suggests that intestinal inflammation is caused by an excessive immune response to mucosal antigens. Recent studies have shown that activation of the aryl hydrocarbon receptor (AhR) induces regulatory T cells (Tregs) and suppresses autoimmune diseases. In the current study, we investigated if nontoxic ligand of AhR, 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), can attenuate dextran sodium sulphate (DSS)-induced colitis. Our studies demonstrated that in mice that received ITE treatment, in-vivo colitis pathogenesis, including a decrease in body weight, was significantly reversed along with the systemic and intestinal inflammatory cytokines. ITE increased the expression of Tregs in spleen, mesenteric lymph nodes (MLNs) and colon lamina propria lymphocytes (cLPL) of mice with colitis when compared to controls. This induction of Tregs was reversed by AhR antagonist treatment in-vitro. ITE treatment also increased dendritic cells (DCs; CD11c+) and decreased F4/80+ (macrophage) from the spleen, MLNs and cLPL in mice with colitis. ITE also reversed the systemic and intestinal frequency of CD4+T cells during colitis and suppressed inflammatory cytokines including IFN-γ, TNF-α, IL-17, IL-6 and IL-1 as well as induced IL-10 levels. These findings suggest that ITE attenuates colitis through induction of Tregs and reduction in inflammatory CD4+ T cells and cytokines. Thus, our work demonstrates that the nontoxic endogenous AhR ligand ITE, may serve as a therapeutic modality to treat IBD.
Grabovsky, Irina; Hess, Brian J; Haist, Steven A; Lipner, Rebecca S; Hawley, Janine L; Woodward, Stephanie; Engleberg, N Cary
2015-03-01
The Infectious Diseases Society of America In-Training Examination (IDSA ITE) is a feedback tool used to help fellows track their knowledge acquisition during fellowship training. We determined whether the scores on the IDSA ITE and from other major medical knowledge assessments predict performance on the American Board of Internal Medicine (ABIM) Infectious Disease Certification Examination. The sample was 1021 second-year fellows who took the IDSA ITE and ABIM Infectious Disease Certification Examination from 2008 to 2012. Multiple regression analysis was used to determine if ABIM Infectious Disease Certification Examination scores were predicted by IDSA ITE scores, prior United States Medical Licensing Examination (USMLE) scores, ABIM Internal Medicine Certification Examination scores, fellowship director ratings of medical knowledge, and demographic variables. Logistic regression was used to evaluate if these same assessments predicted a passing outcome on the certification examination. IDSA ITE scores were the strongest predictor of ABIM Infectious Disease Certification Examination scores (β = .319), followed by prior ABIM Internal Medicine Certification Examination scores (β = .258), USMLE Step 1 scores (β = .202), USMLE Step 3 scores (β = .130), and fellowship directors' medical knowledge ratings (β = .063). IDSA ITE scores were also a significant predictor of passing the Infectious Disease Certification Examination (odds ratio, 1.017 [95% confidence interval, 1.013-1.021]). The significant relationship between the IDSA ITE score and performance on the ABIM Infectious Disease Certification Examination supports the use of the ITE as a valid feedback tool in fellowship training. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Kay, Cynthia; Jackson, Jeffrey L; Frank, Michael
2015-01-01
To explore the relationship between United States Medical Licensing Examination (USMLE) Step 1 scores, yearly in-service training exam (ITE) scores, and passing the American Board of Internal Medicine certifying examination (ABIM-CE). The authors conducted a retrospective database review of internal medicine residents from the Medical College of Wisconsin from 2004 through 2012. Residents' USMLE Step 1, ITE, and ABIM-CE scores were extracted. Pearson rho, chi-square, and logistic regression were used to determine whether relationships existed between the scores and if Step 1 and ITE scores correlate with passing the ABIM-CE. There were 241 residents, who participated in 728 annual ITEs. There were Step 1 scores for 195 (81%) residents and ABIM-CE scores for 183 (76%). Step 1 and ABIM-CE scores had a modest correlation (rho: 0.59), as did ITE and ABIM-CE scores (rho: 0.48-0.67). Failing Step 1 or being in the bottom ITE quartile during any year of testing markedly increased likelihood of failing the boards (Step 1: relative risk [RR]: 2.4; 95% CI: 1.0-5.9; first-year residents' RR: 1.3; 95% CI: 1.0-1.6; second-year residents' RR: 1.3; 95% CI: 1.1-1.5; third-year residents' RR: 1.3; 95% CI: 1.1-1.5). USMLE Step 1 and ITE scores have a modest correlation with board scores. Failing Step 1 or scoring in the bottom quartile of the ITE increased the risk of failing the boards. What effective intervention, if any, program directors may use with at-risk residents is a question deserving further research.
An optical probe for local measurements of fast plasma ion dynamics
NASA Astrophysics Data System (ADS)
Fiksel, G.; Den Hartog, D. J.; Fontana, P. W.
1998-05-01
A novel insertable probe for local measurements of equilibrium and fluctuating plasma ion flow velocity and temperature via Doppler spectroscopy is described. Optical radiation is collected by two fused silica fiber optic bundles with perpendicular viewlines. Spatial resolution of about 5 cm is achieved by terminating each view with an optical dump. The collected light is transported by the fiber bundles to a high-resolution spectrometer. Two components of the velocity are measured simultaneously—the radial along the insertion of the probe and a perpendicular component (which can be varied by simply rotating the probe by 90°). The accuracy of the velocity measurements is better than 1 km/s. The probe is armored by a boron nitride enclosure and is inserted into a high temperature plasma to obtain radial profiles of the equilibrium and fluctuating plasma velocity. Initial measurements have been done in Madison Symmetric Torus reversed field pinch.
Chin, J-H; Lee, E-H; Choi, D-K; Choi, I-C
2011-01-01
Use of intra-operative trans-oesophageal echocardiography (TEE) is an independent risk factor for post-operative dysphagia. This study investigated whether modifying the TEE probe-placement protocol could reduce the incidence of post-operative dysphagia. In group I (n = 100), the TEE probe was inserted after anaesthetic induction and remained in place until the completion of surgery. In group II (n = 100), the TEE probe was inserted after anaesthetic induction, the heart was examined, then the probe was removed. The probe was inserted again before weaning from cardiopulmonary bypass and then immediately removed after examination. The incidence of dysphagia was significantly higher in group I than in group II patients (51.1% versus 28.6%). Multivariate regression analysis showed that the length of time that the TEE probe was in the oesophagus was an independent predictor of dysphagia. Modification of the TEE protocol in this way can reduce the incidence of post-operative dysphagia in cardiac surgery patients.
Narratives as a Vehicle for Mentor and Tutor Knowledge during Feedback in Initial Teacher Education
ERIC Educational Resources Information Center
Philpott, Carey
2016-01-01
This paper argues that the central role of narratives in forming professional knowledge and identity in initial teacher education (ITE) has been overlooked in much recent research into feedback processes in ITE. The paper reviews a broad sample of recent research into mentor and tutor feedback in ITE and identifies that the role of narrating in…
ERIC Educational Resources Information Center
Philpot, Rod
2016-01-01
While an emphasis on social justice has emerged as a theme in initial teacher education (ITE) over the past decade, there is much debate about how to engage ITE students in foregrounding issues of equity and social justice in their own teaching. One strategy, the introduction of critical pedagogy in ITE, has been promoted in teacher education…
Nebraska Industrial Technology Education Teachers Identify the Equipment Their Students Use.
ERIC Educational Resources Information Center
Rogers, George E.
A study asked 287 industrial technology education (ITE) teachers in Nebraska to identify what equipment was being used by ITE students. It also compared ITE equipment usage with regard to school type and school size. The response rate was 59.2 percent (n=170). Findings indicated the drill press and band saw were the most widely used pieces of…
The Predictive Validity of the ABFM's In-Training Examination.
O'Neill, Thomas R; Li, Zijia; Peabody, Michael R; Lybarger, Melanie; Royal, Kenneth; Puffer, James C
2015-05-01
Our objective was to examine the predictive validity of the American Board of Family Medicine's (ABFM) In-Training Examination (ITE) with regard to predicting outcomes on the ABFM certification examination. This study used a repeated measures design across three levels of medical training (PGY1--PGY2, PGY2--PGY3, and PGY3--initial certification) with three different cohorts (2010--2011, 2011--2012, and 2012--2013) to examine: (1) how well the residents' ITE scores correlated with their test scores in the following year, (2) what the typical score increase was across training years, and (3) what was the sensitivity, specificity, positive predictive value, and negative predictive value of the PGY3 scores with regard to predicting future results on the MC-FP Examination. ITE scores generally correlate at about .7 with the following year's ITE or with the following year's certification examination. The mean growth from PGY1 to PGY2 was 52 points, from PGY2 to PGY3 was 34 points, and from PGY3 to initial certification was 27 points. The sensitivity, specificity, positive predictive value, and negative predictive value were .91, .47, .96, and .27, respectively. The ITE is a useful predictor of future ITE and initial certification examination performance.
Iglar, Karl; Leung, Fok-Han; Moineddin, Rahim; Herold, Jodi
2017-05-01
The objective of our study was to assess the correlation between a locally developed In-Training Examination (ITE) and the certification examination in family medicine in Canada. The ITE was taken twice yearly, which corresponded for most residents to the fifth, ninth, 17th, and 21st month of training. The results for the ITE were correlated to the CFPC certification examination taken in the 23rd month of residency. The scores on each of the four iterations of the ITE correlated moderately well with performance relating to problem solving skills and knowledge on the certification examination. The ITE showed a trend to an increased correlation with duration in the training program with a Spearman correlation coefficient increasing from 0.45 on the first test to 0.54 on the fourth test. The correlation of the ITE with performance on the component assessing the doctor- patient relationship on the certification examination was poor (r=0.26 on the last test). Our in-training examination is a useful predictor of performance in problem solving and knowledge domains of the family medicine expert role on the certification examination.
Exploring the quality of life (QOL) in the Indian software industry: a public health viewpoint.
Jha, Ayan; Sadhukhan, Sanjoy Kumar; Velusamy, Saravanan; Banerjee, Gargi; Banerjee, Arpita; Saha, Amitava; Talukdar, Sumit
2012-04-01
Our objectives were to describe the QOL and its determinants among software professionals of Kolkata, and to compare the same according to information technology (IT) and IT-enabled services (ITeS) sub-sectors. An institution-based cross-sectional study was conducted among software professionals of Kolkata applying a two-stage stratified random sampling technique. The WHO QOL BREF questionnaire was administered along with a list of pertinent variables. Overall, the analysis for 338 software professionals (177 IT and 161 ITeS) clearly demonstrated significant differences between mean scores of these two sectors for each of the six outcome domains of WHO QOL BREF. Multilevel multivariate analysis outlined 13 significant predictors of QOL-four positive (age, regular fitness regimes, foreign placements and changing companies frequently) and the rest of the nine, negative (multiple sex partners, multiple addictions, extended working hours, night-shift duties, income, expenditure, carrying office work home, current illness and ITeS company type). Our study helps in obtaining a clear understanding of the multifaceted risk factors prevailing in this sector, the majority of which can be effectively addressed by specific health promotional interventions. A dedicated health policy is mandated at both government and company levels.
The aryl hydrocarbon receptor ligand ITE inhibits TGFβ1-induced human myofibroblast differentiation.
Lehmann, Geniece M; Xi, Xia; Kulkarni, Ajit A; Olsen, Keith C; Pollock, Stephen J; Baglole, Carolyn J; Gupta, Shikha; Casey, Ann E; Huxlin, Krystel R; Sime, Patricia J; Feldon, Steven E; Phipps, Richard P
2011-04-01
Fibrosis can occur in any human tissue when the normal wound healing response is amplified. Such amplification results in fibroblast proliferation, myofibroblast differentiation, and excessive extracellular matrix deposition. Occurrence of these sequelae in organs such as the eye or lung can result in severe consequences to health. Unfortunately, medical treatment of fibrosis is limited by a lack of safe and effective therapies. These therapies may be developed by identifying agents that inhibit critical steps in fibrotic progression; one such step is myofibroblast differentiation triggered by transforming growth factor-β1 (TGFβ1). In this study, we demonstrate that TGFβ1-induced myofibroblast differentiation is blocked in human fibroblasts by a candidate endogenous aryl hydrocarbon receptor (AhR) ligand 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). Our data show that ITE disrupts TGFβ1 signaling by inhibiting the nuclear translocation of Smad2/3/4. Although ITE functions as an AhR agonist, and biologically persistent AhR agonists, such as 2,3,7,8-tetrachlorodibenzo-p-dioxin, cause severe toxic effects, ITE exhibits no toxicity. Interestingly, ITE effectively inhibits TGFβ1-driven myofibroblast differentiation in AhR(-/-) fibroblasts: Its ability to inhibit TGFβ1 signaling is AhR independent. As supported by the results of this study, the small molecule ITE inhibits myofibroblast differentiation and may be useful clinically as an antiscarring agent. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Sisson, Stephen D; Bertram, Amanda; Yeh, Hsin-Chieh
2015-03-01
A core objective of residency education is to facilitate learning, and programs need more curricula and assessment tools with demonstrated validity evidence. We sought to demonstrate concurrent validity between performance on a widely shared, ambulatory curriculum (the Johns Hopkins Internal Medicine Curriculum), the Internal Medicine In-Training Examination (IM-ITE), and the American Board of Internal Medicine Certifying Examination (ABIM-CE). A cohort study of 443 postgraduate year (PGY)-3 residents at 22 academic and community hospital internal medicine residency programs using the curriculum through the Johns Hopkins Internet Learning Center (ILC). Total and percentile rank scores on ILC didactic modules were compared with total and percentile rank scores on the IM-ITE and total scores on the ABIM-CE. The average score on didactic modules was 80.1%; the percentile rank was 53.8. The average IM-ITE score was 64.1% with a percentile rank of 54.8. The average score on the ABIM-CE was 464. Scores on the didactic modules, IM-ITE, and ABIM-CE correlated with each other (P < .05). Residents completing greater numbers of didactic modules, regardless of scores, had higher IM-ITE total and percentile rank scores (P < .05). Resident performance on modules covering back pain, hypertension, preoperative evaluation, and upper respiratory tract infection was associated with IM-ITE percentile rank. Performance on a widely shared ambulatory curriculum is associated with performance on the IM-ITE and the ABIM-CE.
Intrathermocline eddies in the coastal transition zone off central Chile (31-41°S)
NASA Astrophysics Data System (ADS)
Hormazabal, Samuel; Combes, Vincent; Morales, Carmen E.; Correa-Ramirez, Marco A.; Di Lorenzo, Emmanuel; Nuñez, Sergio
2013-10-01
The three-dimensional structure and the origin of mesoscale anticyclonic intrathermocline eddies (ITEs) in the coastal transition zone (CTZ) off central Chile (31-41°S) were analyzed through the combination of data from oceanographic cruises and satellite altimetry, and the application of an eddy-resolving primitive equation ocean model coupled with a numerical experiment using a passive tracer. In this region, ITEs are represented by subsurface lenses (˜100 km diameter; 500 m thickness or vertical extension) of nearly homogeneous salinity (>34.5) and oxygen-deficient (<1.0 mL L-1) waters, properties which are linked to the equatorial subsurface water mass (ESSW) transported poleward by the Peru-Chile undercurrent (PCUC) in the coastal band. At least five to seven ITEs were observed simultaneously in the area between 31° and 38°S during winter cruises in 1997 and 2009. Satellite data indicated that the ITEs identified from in situ data moved westward, each at a mean speed of ˜2 km d-1 and transported a total volume of ˜1 × 106 m3 s-1 (=1 Sv); the lifespan of each ITE ranged from a few months to 1 year. Model results indicate that ITEs become detached from the PCUC under summer upwelling conditions in the coastal zone.
Sisson, Stephen D.; Bertram, Amanda; Yeh, Hsin-Chieh
2015-01-01
Background A core objective of residency education is to facilitate learning, and programs need more curricula and assessment tools with demonstrated validity evidence. Objective We sought to demonstrate concurrent validity between performance on a widely shared, ambulatory curriculum (the Johns Hopkins Internal Medicine Curriculum), the Internal Medicine In-Training Examination (IM-ITE), and the American Board of Internal Medicine Certifying Examination (ABIM-CE). Methods A cohort study of 443 postgraduate year (PGY)-3 residents at 22 academic and community hospital internal medicine residency programs using the curriculum through the Johns Hopkins Internet Learning Center (ILC). Total and percentile rank scores on ILC didactic modules were compared with total and percentile rank scores on the IM-ITE and total scores on the ABIM-CE. Results The average score on didactic modules was 80.1%; the percentile rank was 53.8. The average IM-ITE score was 64.1% with a percentile rank of 54.8. The average score on the ABIM-CE was 464. Scores on the didactic modules, IM-ITE, and ABIM-CE correlated with each other (P < .05). Residents completing greater numbers of didactic modules, regardless of scores, had higher IM-ITE total and percentile rank scores (P < .05). Resident performance on modules covering back pain, hypertension, preoperative evaluation, and upper respiratory tract infection was associated with IM-ITE percentile rank. Conclusions Performance on a widely shared ambulatory curriculum is associated with performance on the IM-ITE and the ABIM-CE. PMID:26217421
Texting preferences in a Paediatric residency.
Draper, Lauren; Kuklinski, Cadence; Ladley, Amy; Adamson, Greg; Broom, Matthew
2017-12-01
Text messaging is ubiquitous among residents, but remains an underused educational tool. Though feasibility has been demonstrated, evidence of its ability to improve standardised test scores and provide insight on resident texting preferences is lacking. The authors set out to evaluate: (1) satisfaction with a hybrid question-and-answer (Q&A) texting format; and (2) pre-/post-paediatric in-training exam (ITE) performance. A prospective study with paediatrics and internal medicine-paediatrics residents. Residents were divided into subgroups: adolescent medicine (AM) and developmental medicine (DM). Messages were derived from ITE questions and sent Monday-Friday with a 20 per cent variance in messages specific to the sub-group. Residents completed surveys gauging perceptions of the programme, and pre- and post-programme ITE scores were analysed. Forty-one residents enrolled and 32 (78%) completed a post-programme survey. Of those, 21 (66%) preferred a Q&A format with an immediate text response versus information-only texts. The percentage change in ITE scores between 2013 and 2014 was significant. Comparing subgroups, there was no significant difference between the percentage change in ITE scores. Neither group performed significantly better on either the adolescent or developmental sections of the ITE. Text messaging… remains an underused educational tool CONCLUSIONS: Overall, participants improved their ITE scores, but no improvement was seen in the targeted subgroups on the exam. Although Q&A texts are preferred by residents, further assessment is required to assess the effect on educational outcomes. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
Perez, Jose A; Greer, Sharon
2009-12-01
The Internal Medicine In-Training Examination (ITE) is administered during residency training in the United States as a self-assessment and program assessment tool. Performance on this exam correlates with outcome on the American Board of Internal Medicine Certifying examination. Internal Medicine Program Directors use the United States Medical Licensing Examination (USMLE) to make decisions in recruitment of potential applicants. This study was done to determine a correlation of USMLE Steps 1, 2 and 3 results with ITE scores in each level of Internal Medicine training. A retrospective review of all residents graduating from an Internal Medicine program from 1999 to 2006 was done. Subjects included had data for all USMLE Steps and ITE during all years of training. Thirty-one subjects were included in the study. Correlations of USMLE Steps 1, 2 and 3 were done with ITE scores (percent correct) in each year of training. Pearson's correlation coefficient (r) was determined for each pairing and a t test to determine statistical significance of the correlation was done. Statistical significance was defined as P value <0.05. The r values for USMLE Step 1 and ITE percent correct in PGY I, II and III were 0.46, 0.55 and 0.51 respectively. Corresponding r values for USMLE Step 2 and ITE percent correct were 0.79, 0.70 and 0.72; for USMLE Step 3 these values were 0.51, 0.37 and 0.51 respectively for each training year. USMLE scores are correlated with ITE scores. This correlation was strongest for USMLE Step 2.
Henry, Ellen C.; Welle, Stephen L.; Gasiewicz, Thomas A.
2010-01-01
The aryl hydrocarbon receptor (AhR), a ligand-dependent transcription factor, mediates toxicity of several classes of xenobiotics and also has important physiological roles in differentiation, reproduction, and immunity, although the endogenous ligand(s) mediating these functions is/are as yet unidentified. One candidate endogenous ligand, 2-(1′H-indolo-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), is a potent AhR agonist in vitro, activates the murine AhR in vivo, but does not induce toxicity. We hypothesized that ITE and the toxic ligand, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), may modify transcription of different sets of genes to account for their different toxicity. To test this hypothesis, primary mouse lung fibroblasts were exposed to 0.5μM ITE, 0.2nM TCDD, or vehicle for 4 h, and total gene expression was evaluated using microarrays. After this short-term and low-dose treatment, several hundred genes were changed significantly, and the response to ITE and TCDD was remarkably similar, both qualitatively and quantitatively. Induced gene sets included the expected battery of AhR-dependent xenobiotic-metabolizing enzymes, as well as several sets that reflect the inflammatory role of lung fibroblasts. Real time quantitative RT-qPCR assay of several selected genes confirmed these microarray data and further suggested that there may be kinetic differences in expression between ligands. These data suggest that ITE and TCDD elicit an analogous change in AhR conformation such that the initial transcription response is the same. Furthermore, if the difference in toxicity between TCDD and ITE is mediated by differences in gene expression, then it is likely that secondary changes enabled by the persistent TCDD, but not by the shorter lived ITE, are responsible. PMID:19933214
Kravchick, Sergey; Yoffe, Boris; Cytron, Shmuel
2007-01-01
To modify our technique of perianal anesthesia and use it in patients with painful conditions of the rectum and/or anus. A total of 31 consecutive patients with anal-rectal problems underwent prostate needle biopsy. Of these, 17 were referred to our hospital after vain attempts to insert a transrectal ultrasound probe. Patients received a perianal-pericapsular injection of 1% lidocaine. Pain perception was separately assessed for probe insertion and biopsies using a visual pain analog score. Only in 1 patient were we unable to insert the transrectal ultrasound probe. The mean patient age was 65.28 +/- 5.35 years. We performed a mean of 12.25 biopsies per case. At probe insertion, the mean pain score was 2.2 +/- 0.83. During the biopsy punctures, the mean pain level was 2.53 +/- 1.054. We did not find any increase in the complication rate related to the anesthesia method. Modified perianal anesthesia can be used for transrectal ultrasound-guided biopsy of the prostate in patients with anal-rectal problems, because it provides significant pain relief.
Jiang, Yi-Zhou; Dai, Cai-Feng; Patankar, Manish S.; Song, Jia-Sheng; Zheng, Jing
2013-01-01
The aryl hydrocarbon receptor (AhR), a ligand-activated transcription factor mediates many biological processes. Herein, we investigated if 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE, an endogenous AhR ligand) regulated proliferation and migration of human ovarian cancer cells via AhR. We found that AhR was widely present in many histotypes of ovarian cancer tissues. ITE suppressed OVCAR-3 cell proliferation and SKOV-3 cell migration in vitro, which were blocked by AhR knockdown. ITE also suppressed OVCAR-3 cell growth in mice. These data suggest that the ITE might potentially be used for therapeutic intervention for at least a subset of human ovarian cancer. PMID:23851185
Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes
NASA Technical Reports Server (NTRS)
Goebel, Dan M.; Jameson, Kristina K.; Watkins, Ron M.; Katz, Ira
2004-01-01
In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.
Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe
Majewski, Stanislaw; Proffitt, James
2010-12-28
A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.
NASA Astrophysics Data System (ADS)
Thomas, Leif N.
2008-08-01
A mechanism for the generation of intrathermocline eddies (ITEs) at wind-forced fronts is examined using a high resolution numerical simulation. Favorable conditions for ITE formation result at fronts forced by "down-front" winds, i.e. winds blowing in the direction of the frontal jet. Down-front winds exert frictional forces that reduce the potential vorticity (PV) within the surface boundary in the frontal outcrop, providing a source for the low-PV water that is the materia prima of ITEs. Meandering of the front drives vertical motions that subduct the low-PV water into the pycnocline, pooling it into the coherent anticyclonic vortex of a submesoscale ITE. As the fluid is subducted along the outcropping frontal isopycnal, the low-PV water, which at the surface is associated with strongly baroclinic flow, re-expresses itself as water with nearly zero absolute vorticity. This generation of strong anticyclonic vorticity results from the tilting of the horizontal vorticity of the frontal jet, not from vortex squashing. During the formation of the ITE, high-PV water from the pycnocline is upwelled alongside the subducting low-PV surface water. The positive correlation between the ITE's velocity and PV fields results in an upward, along-isopycnal eddy PV flux that scales with the surface frictional PV flux driven by the wind. The relationship between the eddy and wind-induced frictional PV flux is nonlocal in time, as the eddy PV flux persists long after the wind forcing is shut off. The ITE's PV flux affects the large-scale flow by driving an eddy-induced transport or bolus velocity down the outcropping isopycnal layer with a magnitude that scales with the Ekman velocity.
Babenko, Oksana; Campbell-Scherer, Denise; Schipper, Shirley; Chmelicek, John; Barber, Tanya; Duerksen, Kimberley; Ross, Shelley
2017-06-01
In our family medicine residency program, we have established a culture of guided self-assessment through a systematic approach of direct observation of residents and documentation of formative feedback. We have observed that our residents have become more accurate in self-assessing their clinical performance. The objective of this study was to examine whether this improved accuracy extended to residents' self-assessment of their medical knowledge and clinical reasoning on the In-Training Examination (ITE). In November each year, residents in their first (PGY1) and second (PGY2) years of residency take the ITE (240 multiple-choice questions). Immediately before and right after taking the ITE, residents complete a questionnaire, self-assessing their knowledge and predicting their performances, overall and in eight high-level domains. Consented data from residents who took the ITE in 2009-2015 (n=380, 60% participation rate) were used in the Generalized Estimating Equations analyses. PGY2 residents outperformed PGY1 residents; Canadian medical graduates consistently outperformed international medical graduates; urban and rural residents performed similarly overall. Residents' pre-post self-assessments were in line with residents' actual performance on the overall examination and in the domains of Adult Medicine and Care of Surgical Patients. The underperforming residents in this study accurately predicted both pre- and post-ITE that they would perform poorly. Our findings suggest that the ITE operates well in our program. There was a tendency among residents in this study to appropriately adjust their self-assessment of their overall performance after completing the ITE. Irrespective of the residency year, resident self-assessment was less accurate on individual domains.
Assessment of first-year post-graduate residents: usefulness of multiple tools.
Yang, Ying-Ying; Lee, Fa-Yauh; Hsu, Hui-Chi; Huang, Chin-Chou; Chen, Jaw-Wen; Cheng, Hao-Min; Lee, Wen-Shin; Chuang, Chiao-Lin; Chang, Ching-Chih; Huang, Chia-Chang
2011-12-01
Objective Structural Clinical Examination (OSCE) usually needs a large number of stations with long test time, which usually exceeds the resources available in a medical center. We aimed to determine the reliability of a combination of Direct Observation of Procedural Skills (DOPS), Internal Medicine in-Training Examination (IM-ITE(®)) and OSCE, and to verify the correlation between the small-scale OSCE+DOPS+IM-ITE(®)-composited scores and 360-degree evaluation scores of first year post-graduate (PGY(1)) residents. Between 2007 January to 2010 January, two hundred and nine internal medicine PGY1 residents completed DOPS, IM-ITE(®) and small-scale OSCE at our hospital. Faculty members completed 12-item 360-degree evaluation for each of the PGY(1) residents regularly. The small-scale OSCE scores correlated well with the 360-degree evaluation scores (r = 0.37, p < 0.021). Interestingly, the addition of DOPS scores to small-scale OSCE scores [small-scale OSCE+DOPS-composited scores] increased it's correlation with 360-degree evaluation scores of PGY(1) residents (r = 0.72, p < 0.036). Further, combination of IM-ITE(®) score with small-scale OSCE+DOPS scores [small-scale OSCE+DOPS+IM-ITE(®)-composited scores] markedly enhanced their correlation with 360-degree evaluation scores (r = 0.85, p < 0.016). The strong correlations between 360-degree evaluation and small-scale OSCE+DOPS+IM-ITE(®)-composited scores suggested that both methods were measuring the same quality. Our results showed that the small-scale OSCE, when associated with both the DOPS and IM-ITE(®), could be an important assessment method for PGY(1) residents. Copyright © 2011. Published by Elsevier B.V.
Predicting success on the certification examinations of the American Board of Anesthesiology.
McClintock, Joseph C; Gravlee, Glenn P
2010-01-01
Currently, residency programs lack objective predictors for passing the sequenced American Board of Anesthesiology (ABA) certification examinations on the first attempt. Our hypothesis was that performance on the ABA/American Society of Anesthesiologists In-Training Examination (ITE) and other variables can predict combined success on the ABA Part 1 and Part 2 examinations. The authors studied 2,458 subjects who took the ITE immediately after completing the first year of clinical anesthesia training and took the ABA Part 1 examination for primary certification immediately after completing residency training 2 yr later. ITE scores and other variables were used to predict which residents would complete the certification process (passing the ABA Part 1 and Part 2 examinations) in the shortest possible time after graduation. ITE scores alone accounted for most of the explained variation in the desired outcome of certification in the shortest possible time. In addition, almost half of the observed variation and most of the explained variance in ABA Part 1 scores was accounted for by ITE scores. A combined model using ITE scores, residency program accreditation cycle length, country of medical school, and gender best predicted which residents would complete the certification examinations in the shortest possible time. The principal implication of this study is that higher ABA/ American Society of Anesthesiologists ITE scores taken at the end of the first clinical anesthesia year serve as a significant and moderately strong predictor of high performance on the ABA Part 1 (written) examination, and a significant predictor of success in completing both the Part 1 and Part 2 examinations within the calendar year after the year of graduation from residency. Future studies may identify other predictors, and it would be helpful to identify factors that predict clinical performance as well.
CrossTalk: The Journal of Defense Software Engineering. Volume 20, Number 10, October 2007
2007-10-01
ch ...Re vie w Va lua tio n Ar ch ite cti ng De ve lop m en t 1 Ar ch ite cti ng 2 Ex plo ra tio n Op er at ion 1 De ve lop m en t 2 Ar ch ite cti ng 3...engineering systems from MIT. MIT 77 Massachusetts AVE NE20-388 Cambridge, MA 02139 Phone: (617) 324-0473 Fax: (617) 258- 7845 E-mail:
Ganesh Kumar, Nishant; Benvenuti, Michael A; Drolet, Brian C
2017-10-01
In-service training examinations (ITEs) are used to assess residents across specialties. However, it is not clear how they are integrated with the Accreditation Council for Graduate Medical Education Milestones and competencies. This study explored the distribution of specialty-specific milestones and competencies in ITEs for plastic surgery and orthopaedic surgery. In-service training examinations were publicly available for plastic surgery (PSITE) and orthopaedics (OITE). Questions on the PSITE for 2014-2016 and the OITE for 2013-2015 were mapped to the specialty-specific milestones and the 6 competencies. There was an uneven distribution of milestones and competencies in ITE questions. Nine of the 36 Plastic Surgery Milestones represented 52% (341 of 650) of questions, and 3 were not included in the ITE. Of 41 Orthopaedic Surgery Milestones, 7 represented 51% (201 of 394) of questions, and 5 had no representation on the ITE. Among the competencies, patient care was the most common (PSITE = 62% [403 of 650]; OITE = 59% [233 of 394]), followed by medical knowledge (PSITE = 34% [222 of 650]; OITE = 31% [124 of 394]). Distribution of the remaining competencies differed between the 2 specialties (PSITE = 4% [25 of 650]; OITE = 9% [37 of 394]). The ITEs tested slightly more than half of the milestones for the 2 specialties, and focused predominantly on patient care and medical knowledge competencies.
End-Cretaceous akaganéite as a mineral marker of Deccan volcanism in the sedimentary record.
Font, Eric; Carlut, Julie; Rémazeilles, Céline; Mather, Tamsin A; Nédélec, Anne; Mirão, José; Casale, Sandra
2017-09-13
An enigmatic chloride-rich iron (oxyhydr)oxide has been recently identified together with mercury anomalies in End-Cretaceous marine sediments coeval with the Deccan Traps eruptions. The mineral was observed in Bidart (France) and Gubbio (Italy), suggesting a widespread phenomenon. However, the exact nature and origin of this Cl-bearing mineral remained speculative. Here, we characterized the accurate composition and nanostructure of this chloride-rich phase by using micro-Raman spectroscopy, Transmission (TEM) and Scanning (SEM) Electron Microscopy on Focused Ion Beam foils. We also provide new evidence of its occurrence in Zumaia, a reference KPg section from Spain. Results confirm akaganéite (β-FeOOH) as the main phase, with chloride content of 3-5 atomic weight %. Akaganéite particles are constituted by the aggregation of nanorods of akaganéite. Internal structures contain empty spaces, suggesting formation in a low-density (atmospheric) environment. This new mineralogical evidence supports the hypothesis that the observed akaganéite was formed in the Deccan volcanic plume and was transported to the Atlantic and Tethysian realms through the stratosphere. Therefore, akaganéite provides a potential new sedimentary marker to identify the imprint of the Deccan eruptions in the stratigraphic record and is evidence of volcanic halogen degassing and its potential role for the Cretaceous-Tertiary mass extinction.
Can Item Keyword Feedback Help Remediate Knowledge Gaps?
Feinberg, Richard A; Clauser, Amanda L
2016-10-01
In graduate medical education, assessment results can effectively guide professional development when both assessment and feedback support a formative model. When individuals cannot directly access the test questions and responses, a way of using assessment results formatively is to provide item keyword feedback. The purpose of the following study was to investigate whether exposure to item keyword feedback aids in learner remediation. Participants included 319 trainees who completed a medical subspecialty in-training examination (ITE) in 2012 as first-year fellows, and then 1 year later in 2013 as second-year fellows. Performance on 2013 ITE items in which keywords were, or were not, exposed as part of the 2012 ITE score feedback was compared across groups based on the amount of time studying (preparation). For the same items common to both 2012 and 2013 ITEs, response patterns were analyzed to investigate changes in answer selection. Test takers who indicated greater amounts of preparation on the 2013 ITE did not perform better on the items in which keywords were exposed compared to those who were not exposed. The response pattern analysis substantiated overall growth in performance from the 2012 ITE. For items with incorrect responses on both attempts, examinees selected the same option 58% of the time. Results from the current study were unsuccessful in supporting the use of item keywords in aiding remediation. Unfortunately, the results did provide evidence of examinees retaining misinformation.
Residency factors that influence pediatric in-training examination score improvement.
Chase, Lindsay H; Highbaugh-Battle, Angela P; Buchter, Susie
2012-10-01
The goal of this study was to determine which measurable factors of resident training experience contribute to improvement of in-training examination (ITE) and certifying examination (CE) scores. This is a descriptive retrospective study analyzing data from July 2003 through June 2006 at a large academic pediatric training program. Pediatric categorical residents beginning residency in July 2003 were included. Regression analyses were used to determine if the number of admissions performed, core lectures attended, acute care topics heard, grand rounds attended, continuity clinic patients encountered, or procedures performed correlated with improvement of ITE scores. These factors were then analyzed in relation to CE scores. Seventeen residents were included in this study. The number of general pediatric admissions was the only factor found to correlate with an increase in ITE score (P = .04). Scores for the ITE at pediatric levels 1 and 3 were predictive of CE scores. No other factors measured were found to influence CE scores. Although all experiences of pediatric residents likely contribute to professional competence, some experiences may have more effect on ITE and CE scores. In this study, only general pediatric admissions correlated significantly with an improvement in ITE scores from year 1 to year 3. Further study is needed to identify which elements of the residency experience contribute most to CE success. This would be helpful in optimizing residency program structure and curriculum within the limitations of duty hour regulations.
Weng, Hong; Zeng, Xian-Tao; Li, Sheng; Meng, Xiang-Yu; Shi, Ming-Jun; He, Da-Lin; Wang, Xing-Huan
2017-09-13
The present study aimed to systematically evaluate the effectiveness and safety of the intrafascial and interfascial nerve sparing (ITR-NS and ITE-NS) radical prostatectomy. PubMed, Embase, and Cochrane Library databases were searched for eligible studies. Meta-analysis with random-effects model was performed. Six comparative trials were selected and embraced in this research, including one randomized controlled trial, three prospective comparative trials, and two retrospective comparative trials. With regard to perioperative parameters, no significant association of operative time, blood loss, transfusion rates, duration of catheterization, and hospital stay existed between ITR-NS and ITE-NS. With respect to the functional results, ITR-NS had advantages in terms of both continence and potency recovery compared with ITE-NS. In reference to the oncologic results, the ITR-NS showed lower overall positive surgical margin (PSM) compared with ITE-NS but pT2 PSM and biochemical recurrence free rates were similar to the two surgical types. This study demonstrates that ITR-NS has better continence at 6 mo and 36 mo and better potency recovery at 6 mo and 12 mo postoperatively, regardless of the surgical technique. The cancer control of ITR-NS was also better than that of ITE-NS. This may be explained by the fact that patients in ITE-NS group present higher risk cancer than patients in ITR-NS group.
RNA detection using peptide-inserted Renilla luciferase.
Andou, Takashi; Endoh, Tamaki; Mie, Masayasu; Kobatake, Eiry
2009-01-01
A novel complementation system with short peptide-inserted-Renilla luciferase (PI-Rluc) and split-RNA probes was constructed for noninvasive RNA detection. The RNA binding peptides HIV-1 Rev and BIV Tat were used as inserted peptides. They display induced fit conformational changes upon binding to specific RNAs and trigger complementation or discomplementation of Rluc. Split-RNA probes were designed to reform the peptide binding site upon hybridization with arbitrarily selected target RNA. This set of recombinant protein and split-RNA probes enabled a high degree of sensitivity in RNA detection. In this study, we show that the Rluc system is comparable to Fluc, but that its detection limit for arbitrarily selected RNA (at least 100 pM) exceeds that of Fluc by approximately two orders of magnitude.
Su, Xiaogang; Peña, Annette T; Liu, Lei; Levine, Richard A
2018-04-29
Assessing heterogeneous treatment effects is a growing interest in advancing precision medicine. Individualized treatment effects (ITEs) play a critical role in such an endeavor. Concerning experimental data collected from randomized trials, we put forward a method, termed random forests of interaction trees (RFIT), for estimating ITE on the basis of interaction trees. To this end, we propose a smooth sigmoid surrogate method, as an alternative to greedy search, to speed up tree construction. The RFIT outperforms the "separate regression" approach in estimating ITE. Furthermore, standard errors for the estimated ITE via RFIT are obtained with the infinitesimal jackknife method. We assess and illustrate the use of RFIT via both simulation and the analysis of data from an acupuncture headache trial. Copyright © 2018 John Wiley & Sons, Ltd.
Wang, Kai; Li, Yan; Jiang, Yi-Zhou; Dai, Cai-Feng; Patankar, Manish S; Song, Jia-Sheng; Zheng, Jing
2013-10-28
The aryl hydrocarbon receptor (AhR), a ligand-activated transcription factor mediates many biological processes. Herein, we investigated if 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE, an endogenous AhR ligand) regulated proliferation and migration of human ovarian cancer cells via AhR. We found that AhR was widely present in many histotypes of ovarian cancer tissues. ITE suppressed OVCAR-3 cell proliferation and SKOV-3 cell migration in vitro, which were blocked by AhR knockdown. ITE also suppressed OVCAR-3 cell growth in mice. These data suggest that the ITE might potentially be used for therapeutic intervention for at least a subset of human ovarian cancer. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Submillisecond Dynamics of Mastoparan X Insertion into Lipid Membranes.
Schuler, Erin E; Nagarajan, Sureshbabu; Dyer, R Brian
2016-09-01
The mechanism of protein insertion into a lipid bilayer is poorly understood because the kinetics of this process is difficult to measure. We developed a new approach to study insertion of the antimicrobial peptide Mastoparan X into zwitterionic lipid vesicles, using a laser-induced temperature-jump to initiate insertion on the microsecond time scale and infrared and fluorescence spectroscopies to follow the kinetics. Infrared probes the desolvation of the peptide backbone and yields biphasic kinetics with relaxation lifetimes of 12 and 117 μs, whereas fluorescence probes the intrinsic tryptophan residue located near the N-terminus and yields a single exponential phase with a lifetime of 440 μs. Arrhenius analysis of the temperature-dependent rates yields an activation energy for insertion of 96 kJ/mol. These results demonstrate the complexity of the insertion process and provide mechanistic insight into the interplay between peptides and the lipid bilayer required for peptide transport across cellular membranes.
Rugged fiber optic probe for raman measurement
O'Rourke, Patrick E.; Toole, Jr., William R.; Nave, Stanley E.
1998-01-01
An optical probe for conducting light scattering analysis is disclosed. The probe comprises a hollow housing and a probe tip. A fiber assembly made up of a transmitting fiber and a receiving bundle is inserted in the tip. A filter assembly is inserted in the housing and connected to the fiber assembly. A signal line from the light source and to the spectrometer also is connected to the filter assembly and communicates with the fiber assembly. By using a spring-loaded assembly to hold the fiber connectors together with the in-line filters, complex and sensitive alignment procedures are avoided. The close proximity of the filter assembly to the probe tip eliminates or minimizes self-scattering generated by the optical fiber. Also, because the probe can contact the sample directly, sensitive optics can be eliminated.
NASA Astrophysics Data System (ADS)
Lecomte, A.; Castagnola, V.; Descamps, E.; Dahan, L.; Blatché, M. C.; Dinis, T. M.; Leclerc, E.; Egles, C.; Bergaud, C.
2015-12-01
The use of soft materials as substrate for neural probes aims at achieving better compliance with the surrounding neurons while maintaining minimal rejection. Many strategies have emerged to enable such probes to penetrate the cortex, among which the use of resorbable polymers. We performed several tests involving two resorbable polymers considered most promising: polyethylene glycol (PEG) and silk fibroin (SF) from Bombyx Mori silkworms. Our coating method provides a repeatable, uniform structure optimized for a stress-reduced insertion of a parylene-C neural probe. Standard compression tests as well as in vitro and in vivo insertion assessments show that both SF and PEG-coated probes are stiff enough to avoid the buckling effect during insertion in the cortex. However, with a buckling force of 300 mN and a mechanical holding in vitro of tens of minutes, we assess silk fibroin to be more reliable for practical handling. In vivo first try-outs in mouse brain showed neither buckling issues of the probe nor undesired alteration of the signal recording. Moreover, we evidenced two distinct time scales in the bioresorption of our polymer coatings: silk fibroin degrades itself in a matter of weeks and PEG dissolves itself within seconds in the presence of water. We then present a hybrid PEG and SF coating that could be used as a drug delivery system with different time scales to reduce both the acute and the chronic body reaction.
Mathis, Bradley R; Warm, Eric J; Schauer, Daniel P; Holmboe, Eric; Rouan, Gregory W
2011-11-01
The Internal Medicine In-Training Exam (IM-ITE) assesses the content knowledge of internal medicine trainees. Many programs use the IM-ITE to counsel residents, to create individual remediation plans, and to make fundamental programmatic and curricular modifications. To assess the association between a multiple-choice testing program administered during 12 consecutive months of ambulatory and inpatient elective experience and IM-ITE percentile scores in third post-graduate year (PGY-3) categorical residents. Retrospective cohort study. One hundred and four categorical internal medicine residents. Forty-five residents in the 2008 and 2009 classes participated in the study group, and the 59 residents in the three classes that preceded the use of the testing program, 2005-2007, served as controls. A comprehensive, elective rotation specific, multiple-choice testing program and a separate board review program, both administered during a continuous long-block elective experience during the twelve months between the second post-graduate year (PGY-2) and PGY-3 in-training examinations. We analyzed the change in median individual percent correct and percentile scores between the PGY-1 and PGY-2 IM-ITE and between the PGY-2 and PGY-3 IM-ITE in both control and study cohorts. For our main outcome measure, we compared the change in median individual percentile rank between the control and study cohorts between the PGY-2 and the PGY-3 IM-ITE testing opportunities. After experiencing the educational intervention, the study group demonstrated a significant increase in median individual IM-ITE percentile score between PGY-2 and PGY-3 examinations of 8.5 percentile points (p < 0.01). This is significantly better than the increase of 1.0 percentile point seen in the control group between its PGY-2 and PGY-3 examination (p < 0.01). A comprehensive multiple-choice testing program aimed at PGY-2 residents during a 12-month continuous long-block elective experience is associated with improved PGY-3 IM-ITE performance.
Improved efficiency of nanoneedle insertion by modification with a cell-puncturing protein
NASA Astrophysics Data System (ADS)
Ryu, Seunghwan; Matsumoto, Yuta; Matsumoto, Takahiro; Ueno, Takafumi; Silberberg, Yaron R.; Nakamura, Chikashi
2018-03-01
An atomic force microscope (AFM) probe etched into an ultra-sharp cylindrical shape (a nanoneedle) can be inserted into a living cell and mechanical responses of the insertion process are represented as force-distance curves using AFM. A probe-molecule-functionalized nanoneedle can be used to detect intracellular molecules of interest in situ. The insertion efficiencies of nanoneedles vary among cell types due to the cortex structures of cells, and some cell types, such as mouse fibroblast Balb/3T3 cells, show extremely low efficacy of insertion. We addressed this issue by using a cell membrane puncturing protein from bacteriophage T4 (gp5), a needle-like protein that spontaneously penetrates through the cell membrane. Gp5 was immobilized onto a nanoneedle surface. The insertion efficiency of the functionalized nanoneedle increased by over 15% compared to the non-functionalized control. Gp5-modification is a versatile approach in cell manipulation techniques for the insertion of other types of nanostructures into cells.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Lee, P. L.; Ellis, S.; Selzer, R. H.; Ortendahl, D. A.
1994-01-01
Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.
Can Item Keyword Feedback Help Remediate Knowledge Gaps?
Feinberg, Richard A.; Clauser, Amanda L.
2016-01-01
ABSTRACT Background In graduate medical education, assessment results can effectively guide professional development when both assessment and feedback support a formative model. When individuals cannot directly access the test questions and responses, a way of using assessment results formatively is to provide item keyword feedback. Objective The purpose of the following study was to investigate whether exposure to item keyword feedback aids in learner remediation. Methods Participants included 319 trainees who completed a medical subspecialty in-training examination (ITE) in 2012 as first-year fellows, and then 1 year later in 2013 as second-year fellows. Performance on 2013 ITE items in which keywords were, or were not, exposed as part of the 2012 ITE score feedback was compared across groups based on the amount of time studying (preparation). For the same items common to both 2012 and 2013 ITEs, response patterns were analyzed to investigate changes in answer selection. Results Test takers who indicated greater amounts of preparation on the 2013 ITE did not perform better on the items in which keywords were exposed compared to those who were not exposed. The response pattern analysis substantiated overall growth in performance from the 2012 ITE. For items with incorrect responses on both attempts, examinees selected the same option 58% of the time. Conclusions Results from the current study were unsuccessful in supporting the use of item keywords in aiding remediation. Unfortunately, the results did provide evidence of examinees retaining misinformation. PMID:27777664
Measurement of food texture by an acoustic vibration method
NASA Astrophysics Data System (ADS)
Sakurai, Naoki; Taniwaki, Mitsuru; Iwatani, Shin-ichiro; Akimoto, Hidemi
2011-09-01
Food texture was measured by a new acoustic vibration method. A piezoelectric sensor sandwiched between a probe and piston was inserted into a food sample by delivery of silicon oil to a cylinder by a pump. Vibration emitted from the food sample on insertion of the probe was monitored by voltage outputs of the sensor. The voltage signals were passed through 19 half octave bands to calculate texture index for each band. The texture index was defined as vibration energy of the probe caused by the food rupture and/or breakage per unit time.
A probe for blood-vessel and spinal interiors
NASA Technical Reports Server (NTRS)
Frazer, R. E.
1978-01-01
Probe design allows insertion into lumen of blood vessels to perform oximetry and investigate plaque on interior vessel walls. Probe is more accurate than standard oximetry procedures of determining oxygenation of circulating blood.
Lung transplant curriculum in pulmonary/critical care fellowship training.
Hayes, Don; Diaz-Guzman, Enrique; Berger, Rolando; Hoopes, Charles W
2013-01-01
Lung transplantation is an evolving specialty with the number of transplants growing annually. A structured lung transplant curriculum was developed for Pulmonary/Critical Care (Pulm/CC) fellows. Scores on pulmonary in-training examinations (ITE) 2 years prior to and 3 years after implementation were reviewed as well as completion of satisfaction surveys. The mean pulmonary ITE score of 1st-year fellows increased from 54.2 ± 2.5 to 63.6 ± 1.2 (M ± SD), p = .002, whereas mean pulmonary ITE score for 2nd-year fellows increased from 63.0 ± 3.0 to 70.7 ± 1.2, p = .019. The combined mean pulmonary ITE score increased from 58.6 ± 2.3 to 67.1 ± 1.2, p = .001. Satisfaction surveys revealed that fellow perception of the curriculum was that the experience contributed to an overall improvement in their knowledge base and clinical skills while opportunity to perform transbronchial biopsies was available. A structured educational lung transplant curriculum was associated with improved performance on the pulmonary ITE and was perceived by fellows to be beneficial in their education and training while providing opportunities for fellows to perform transbronchial biopsies.
Comparison of nine methods to estimate ear-canal stimulus levels
Souza, Natalie N.; Dhar, Sumitrajit; Neely, Stephen T.; Siegel, Jonathan H.
2014-01-01
The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion depth. The remaining five quantities were derived from the ear-canal pressure and the Thévenin-equivalent source characteristics of the probe: Forward pressure, initial forward pressure, the pressure transmitted into the middle ear, eardrum sound pressure estimated by summing the magnitudes of the forward and reverse pressure (integrated pressure) and absorbed power. Two sets of behavioral thresholds were measured in 26 subjects from 0.125 to 20 kHz, with the probe inserted at relatively deep and shallow positions in the ear canal. The greatest dependence on insertion depth was for transmitted pressure and absorbed power. The measures with the least dependence on insertion depth throughout the frequency range (best performance) included the depth-compensated simulator, eardrum, forward, and integrated pressures. Among these, forward pressure is advantageous because it quantifies stimulus phase. PMID:25324079
In vivo performance of a microelectrode neural probe with integrated drug delivery
Rohatgi, Pratik; Langhals, Nicholas B.; Kipke, Daryl R.; Patil, Parag G.
2014-01-01
Object The availability of sophisticated neural probes is a key prerequisite in the development of future brain machine interfaces (BMI). In this study, we developed and validated a neural probe design capable of simultaneous drug delivery and electrophysiology recordings in vivo. Focal drug delivery has promise to dramatically extend the recording lives of neural probes, a limiting factor to clinical adoption of BMI technology. Methods To form the multifunctional neural probe, we affixed a 16-channel microfabricated silicon electrode array to a fused silica catheter. Three experiments were conducted to characterize the performance of the device. Experiment 1 examines cellular damage from probe insertion and the drug distribution in tissue. Experiment 2 measures the effects of saline infusions delivered through the probe on concurrent electrophysiology. Experiment 3 demonstrates that a physiologically relevant amount of drug can be delivered in a controlled fashion. For these experiments, Hoechst and propidium iodide were used to assess insertion trauma and the tissue distribution of the infusate. Artificial cerebral spinal fluid and tetrodotoxin were injected to determine the efficacy of drug delivery. Results The newly developed multifunctional neural probes were successfully inserted into rat cortex and were able to deliver fluids and drugs that resulted in the expected electrophysiological and histological responses. The damage from insertion of the device into brain tissue was substantially less than the volume of drug dispersion in tissue. Electrophysiological activity, including both individual spikes as well as local field potentials, was successfully recorded with this device during real-time drug delivery. No significant changes were seen in response to delivery of artificial cerebral spinal fluid as a control experiment, whereas delivery of tetrodotoxin produced the expected result of suppressing all spiking activity in the vicinity of the catheter outlet. Conclusions Multifunctional neural probes such as the ones developed and validated within this study have great potential to help further understand the design space and criteria for the next generation of neural probe technology. By incorporating integrated drug delivery functionality into the probes, new treatment options for neurological disorders and regenerative neural interfaces utilizing localized and feedback controlled delivery of drugs can be realized in the near future. PMID:19569896
Impact of Residency Training Redesign on Residents' Clinical Knowledge.
Waller, Elaine; Eiff, M Patrice; Dexter, Eve; Rinaldo, Jason C B; Marino, Miguel; Garvin, Roger; Douglass, Alan B; Phillips, Robert; Green, Larry A; Carney, Patricia A
2017-10-01
The In-training Examination (ITE) is a frequently used method to evaluate family medicine residents' clinical knowledge. We compared family medicine ITE scores among residents who trained in the 14 programs that participated in the Preparing the Personal Physician for Practice (P4) Project to national averages over time, and according to educational innovations. The ITE scores of 802 consenting P4 residents who trained in 2007 through 2011 were obtained from the American Board of Family Medicine. The primary analysis involved comparing scores within each academic year (2007 through 2011), according to program year (PGY) for P4 residents to all residents nationally. A secondary analysis compared ITE scores among residents in programs that experimented with length of training and compared scores among residents in programs that offered individualized education options with those that did not. Release of ITE scores was consented to by 95.5% of residents for this study. Scores of P4 residents were higher compared to national scores in each year. For example, in 2011, the mean P4 score for PGY1 was 401.2, compared to the national average of 386. For PGY2, the mean P4 score was 443.1, compared to the national average of 427, and for PGY3, the mean P4 score was 477.0, compared to the national PGY3 score of 456. Scores of residents in programs that experimented with length of training were similar to those in programs that did not. Scores were also similar between residents in programs with and without individualized education options. Family medicine residency programs undergoing substantial educational changes, including experiments in length of training and individualized education, did not appear to experience a negative effect on resident's clinical knowledge, as measured by ITE scores. Further research is needed to study the effect of a wide range of residency training innovations on ITE scores over time.
Trace Element Abundances in Eucrite Basalts: Enrichment or Depletion?
NASA Astrophysics Data System (ADS)
Castle, N. R.
2018-05-01
It is not clear how incompatible trace element (ITE) variation in eucrite basalts originated. Here, mechanisms for relative ITE enrichment or depletion are experimentally evaluated in an attempt to reconcile the Stannern and main group eucrites.
Genome-wide transcriptional profiling of human glioblastoma cells in response to ITE treatment.
Kang, Bo; Zhou, Yanwen; Zheng, Min; Wang, Ying-Jie
2015-09-01
A ligand-activated transcription factor aryl hydrocarbon receptor (AhR) is recently revealed to play a key role in embryogenesis and tumorigenesis (Feng et al. [1], Safe et al. [2]) and 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) (Song et al. [3]) is an endogenous AhR ligand that possesses anti-tumor activity. In order to gain insights into how ITE acts via the AhR in embryogenesis and tumorigenesis, we analyzed the genome-wide transcriptional profiles of the following three groups of cells: the human glioblastoma U87 parental cells, U87 tumor sphere cells treated with vehicle (DMSO) and U87 tumor sphere cells treated with ITE. Here, we provide the details of the sample gathering strategy and show the quality controls and the analyses associated with our gene array data deposited into the Gene Expression Omnibus (GEO) under the accession code of GSE67986.
Methods and instruments for materials testing
NASA Technical Reports Server (NTRS)
Hansma, Paul (Inventor); Drake, Barney (Inventor); Rehn, Douglas (Inventor); Adams, Jonathan (Inventor); Lulejian, Jason (Inventor)
2011-01-01
Methods and instruments for characterizing a material, such as the properties of bone in a living human subject, using a test probe constructed for insertion into the material and a reference probe aligned with the test probe in a housing. The housing is hand held or placed so that the reference probe contacts the surface of the material under pressure applied either by hand or by the weight of the housing. The test probe is inserted into the material to indent the material while maintaining the reference probe substantially under the hand pressure or weight of the housing allowing evaluation of a property of the material related to indentation of the material by the probe. Force can be generated by a voice coil in a magnet structure to the end of which the test probe is connected and supported in the magnet structure by a flexure, opposing flexures, a linear translation stage, or a linear bearing. Optionally, a measurement unit containing the test probe and reference probe is connected to a base unit with a wireless connection, allowing in the field material testing.
Effects of high Z probe on plasma behavior in HT-6M tokamak
NASA Astrophysics Data System (ADS)
Li, J.; Gong, X.; Luo, L.; Yin, F. X.; Noda, N.; Wan, B.; Xu, W.; Gao, X.; Yin, F.; Jiang, J. G.; Wu, Z.; Zhao, J. Y.; Wu, M.; Liu, S.; Han, Y.
1997-02-01
Molybdenum and tungsten probes have been tested in HT-6M tokamak under various discharge conditions aiming to find out the conditions in which high Z PFC can be used without serious degradation of core plasma performance. In normal OH discharges, the degradation of core plasma performance was found only when the probe was inserted beyond 3.0 cm inside the last closed flux surface (LCFS). The plasma performance did not change with positive biasing to the probe, whereas central Te degraded during negative biasing of -100 V. The insertion of the Mo probe to 1.5 cm inside the LCFS made a change in the threshold power of the L-H transition in EOH discharges. These results suggest a certain operation range of the H-mode in the EOH discharge with the Mo probe in HT-6M.
Thermal Design, Analysis, and Testing of the Quench Module Insert Bread Board
NASA Technical Reports Server (NTRS)
Breeding, Shawn; Khodabandeh, Julia
2002-01-01
Contents include the following: Quench Module Insert (QMI) science requirements. QMI interfaces. QMI design layout. QMI thermal analysis and design methodology. QMI bread board testing and instrumentation approach. QMI thermal probe design parameters. Design features for gradient measurement. Design features for heated zone measurements. Thermal gradient analysis results. Heated zone analysis results. Bread board thermal probe layout. QMI bread board correlation and performance. Summary and conclusions.
Bärlund, M; Nupponen, N N; Karhu, R; Tanner, M M; Paavola, P; Kallioniemi, O P; Kallioniemi, A
1998-01-01
Defining boundaries of chromosomal rearrangements at the molecular level would benefit from landmarks that link the cytogenetic map to physical, genetic, and transcript maps, as well as from large-insert FISH probes for such loci to detect numerical and structural rearrangements in metaphase or interphase cells. Here, we determined the locations of 24 genetically mapped CEPH-Mega YACs along the FLpter scale (fractional length from p-telomere) by quantitative fluorescence in situ hybridization analysis. This generated a set of cytogenetically mapped probes for chromosome 17 with an average spacing of about 5 cM. We then developed large-insert YAC, BAC, PAC, or P1 clones to the following 24 known genes, and determined refined map locations along the same FLpter scale: pter-TP53-TOP3-cen-TNFAIP1-ERBB2-TOP2A- BRCA1-TCF11-NME1-HLF-ZNF147/CL N80-BCL5/MPO/SFRS1-TBX2-PECAM1-DDX5/ PRKCA-ICAM2-GH1/PRKAR1A-GRB2-CDK3 /FKHL13-qter. Taken together, these 48 cytogenetically mapped large-insert probes provide tools for the molecular analysis of chromosome 17 rearrangements, such as mapping amplification, deletion, and translocation breakpoints in this chromosome, in cancer and other diseases.
ITE Trip Generation Modification Factors for Louisiana : Research Project Capsule
DOT National Transportation Integrated Search
2017-12-01
Using data from studies conducted in the United States over the last 50-60 years, the Institute of Transportation Engineers (ITE) has published trip generation rates for different land uses. Over time, observations from new studies have been incorpor...
Wray, Alisa; Bennett, Kathryn; Boysen-Osborn, Megan; Wiechmann, Warren; Toohey, Shannon
2017-01-01
The aim of this study was to measure the effect of an iPad-based asynchronous curriculum on emergency medicine resident performance on the in-training exam (ITE). We hypothesized that the implementation of an asynchronous curriculum (replacing 1 hour of weekly didactic time) would result in non-inferior ITE scores compared to the historical scores of residents who had participated in the traditional 5-hour weekly didactic curriculum. The study was a retrospective, non-inferiority study. conducted at the University of California, Irvine Emergency Medicine Residency Program. We compared ITE scores from 2012 and 2013, when there were 5 weekly hours of didactic content, with scores from 2014 and 2015, when 1 hour of conference was replaced with asynchro-nous content. Examination results were compared using a non-inferiority data analysis with a 10% margin of difference. Using a non-inferiority test with a 95% confidence interval, there was no difference between the 2 groups (before and after implementation of asynchronous learning), as the confidence interval for the change of the ITE was -3.5 to 2.3 points, whereas the 10% non-inferiority margin was 7.8 points. Replacing 1 hour of didactic conference with asynchronous learning showed no negative impact on resident ITE scores.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bulbulian, R.; Bond, M.
1994-01-01
The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle ergometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Bernauer, E. M.; Ertl, A. C.; Bond, M.; Bulbulian, R.
1994-01-01
The purpose of our study was to determine if an intensive, intermittent, isokinetic, lower extremity exercise training program would attenuate or eliminate the decrease of muscular strength and endurance during prolonged bed rest (BR). The 19 male subjects (36 +/- 1 yr, 178 +/- 2 cm, 76.5 +/- 1.7 kg) were allocated into a no exercise (NOE) training group (N = 5), an isotonic (lower extremity cycle orgometer) exercise (ITE) training group (N = 7), and an isokinetic (isokinetic knee flexion-extension) exercise (IKE) training group (N = 7). Peak knee (flexion and extension) and shoulder (abduction-adduction) functions were measured weekly in all groups with one 5-repetition set. After BR, average knee extension total work decreased by 16% with NOE, increased by 27% with IKE, and was unchanged with ITE. Average knee flexion total work and peak torque (strength) responses were unchanged in all groups. Force production increased by 20% with IKE and was unchanged with NOE and ITE. Shoulder total work was unchanged in all groups, while gross average peak torque increased by 27% with ITE and by 22% with IKE, and was unchanged with NOE. Thus, while ITE training can maintain some isokinetic functions during BR, maximal intermittent IKE training can increase other functions above pre-BR control levels.
Tn5099, a xylE promoter probe transposon for Streptomyces spp.
Hahn, D R; Solenberg, P J; Baltz, R H
1991-01-01
Tn5099, a promoter probe transposon for Streptomyces spp., was constructed by inserting a promoterless xylE gene and a hygromycin resistance gene into IS493. Tn5099 transposed into different sites in the Streptomyces griseofuscus genome, and the xylE reporter gene was expressed in some of the transposition mutants. Strains containing Tn5099 insertions that gave regulated expression of the xylE gene were identified. Images PMID:1653213
NASA Astrophysics Data System (ADS)
Leite, Laurinda; Dourado, Luís; Morgado, Sofia
2016-12-01
Between the 1980s and 2007, Portugal used to have one-stage (5-year period) initial teacher education (ITE) programs. In 2007 and consistent with the Bologna process guidelines, Portuguese teacher education moved toward a two-stage model, which includes a 3-year undergraduate program of subject matter that leads to a licenciatura (or bachelor) degree and a 3-year professional master in the teaching of a subject. The way that teacher educators perceive the ITE programs effects the education of prospective teachers and consequently the future of science education. This paper aims at analyzing how science teacher educators perceived the changes that took place in this formal way of educating junior school (7th-9th grades) and high school (10th-12th grades) science teachers in Portugal, due to the implementation of the Bologna guidelines. To attain the objectives of the study, 33 science teacher educators including science specialists and science education specialists answered an open-ended online questionnaire, which focused on the strengths and weaknesses of the pre- and post-Bologna ITE programs, the overall quality of teacher education and measures for improving ITE. The results indicate that science teacher educators were quite happy with all of the ITE models, but they expressed the belief that both the science and the teaching practice components should be strengthened in the post-Bologna masters in teaching. Meanwhile, changes were introduced in Portuguese educational laws, and they proved to be consistent with the opinions of the participants. However, the professional development of teacher educators along with evidence-based ITE programs seems to be necessary conditions for overcoming the challenges that teacher education is still facing in Portugal and worldwide.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Ertl, A. C.; Bernauer, E. M.
1996-01-01
BACKGROUND: Maintaining intermediary metabolism is necessary for the health and well-being of astronauts on long-duration spaceflights. While peak oxygen uptake (VO2) is consistently decreased during prolonged bed rest, submaximal VO2 is either unchanged or decreased. METHODS: Submaximal exercise metabolism (61 +/- 3% peak VO2) was measured during ambulation (AMB day-2) and on bed rest days 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N = 5) control, and isotonic exercise (ITE, N = 7) and isokinetic exercise (IKE, N = 7) training groups. Exercise training was conducted supine for two 30-min periods per day for 6 d per week: ITE training was intermittent at 60-90% peak VO2; IKE training was 10 sets of 5 repetitions of peak knee flexion-extension force at a velocity of 100 degrees s-1. Cardiac output was measured with the indirect Fick CO2 method, and plasma volume with Evans blue dye dilution. RESULTS: Supine submaximal exercise VO2 decreased significantly (*p < 0.05) by 10.3%* with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output decrease of 14.5%* (ITE) and 20.3%* (IKE), but different from change in peak VO2 (+1.4% with ITE and -10.2%* with IKE) and decrease in plasma volume of -3.7% (ITE) and -18.0%* (IKE). Reduction of submaximal VO2 during bed rest correlated 0.79 (p < 0.01) with submaximal Qc, but was not related to change in peak VO2 or plasma volume. CONCLUSION: Reduction in submaximal oxygen uptake during prolonged bed rest is related to decrease in exercise but not resting cardiac output; perturbations in active skeletal muscle metabolism may be involved.
Cinar, Betul Cicek; Yarali, Mehmet; Atay, Gamze; Bajin, Munir Demir; Sennaroglu, Gonca; Sennaroglu, Levent
2017-09-01
The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.
Development of a high-value care subscore on the internal medicine in-training examination.
Ryskina, Kira L; Korenstein, Deborah; Weissman, Arlene; Masters, Philip; Alguire, Patrick; Smith, Cynthia D
2014-11-18
Although high-value care (HVC) that balances benefits of tests or treatments against potential harms and costs has been a recently emphasized competency for internal medicine (IM) residents, few tools to assess residents' knowledge of HVC are available. To describe the development and initial results of an HVC subscore of the Internal Medicine In-Training Examination (IM-ITE). The HVC concepts were introduced to IM-ITE authors during question development. Three physicians independently reviewed each examination question for selection in the HVC subscore according to 6 HVC principles. The final subscore was determined by consensus. Data from the IM-ITE administered in October 2012 were analyzed at the program level. U.S. IM residency programs. 362 U.S. IM residency programs with IM-ITE data for at least 10 residents. Program-level performance on the HVC subscore was compared with performance on the overall IM-ITE, the Dartmouth Atlas hospital care intensity (HCI) index of the program's primary training hospital, and residents' attitudes about HVC assessed with a voluntary survey. The HVC subscore comprised 38 questions, including 21 (55%) on managing conservatively when appropriate and 14 (37%) on identifying low-value care. Of the 362 U.S. IM programs in the sample, 41% were in a different quartile when ranked based on the HVC subscore compared with overall IM-ITE performance. Rankings by HVC subscore and HCI index were modestly inversely associated, with 30% of programs ranked in the same quartile based on both measures. Knowledge of HVC assessed from examination vignettes may not reflect practice of HVC. Although the HVC subscore has face validity and can contribute to evaluation of residents' HVC knowledge, additional tools are needed to accurately measure residents' proficiency in HVC. None.
Wei, Ping; Hu, Guo-Hua; Kang, Hou-Yong; Yao, Hong-Bing; Kou, Wei; Liu, Hong; Zhang, Cheng; Hong, Su-Ling
2014-05-01
A predominant Th17 population is a marker of allergic rhinitis (AR). The aryl hydrocarbon receptor (AhR) exhibits strong immunomodulation potential via regulation of the differentiation of T lymphocytes and dendritic cells (DCs) after activation by its ligand, such as 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). The aim of this study was to analyze the effect of AhR on Th17 differentiation by investigating the action of ITE on DCs and CD4(+) T cells from patients with AR. In all, 26 AR patients and 12 healthy controls were included in this study. The expression of interleukin (IL)-1β, IL-6, IL-10, and IL-17 in the culture supernatant and the presence of Th17 cells in CD4(+) T cells and DC-CD4(+) T-cell co-culture system were measured before and after treatment with ITE. We show that ITE significantly induced cell secretion of IL-10 and inhibited IL-1β and IL-6 production in DCs, and promoted IL-10 production and suppressed IL-17 expression in CD4(+) T cells in vitro. It also suppressed the expansion of Th17 cells in vitro. Our work demonstrates that ITE acts on DCs and CD4(+) T cells to inhibit the Th17 response that suppresses AR; the AhR-DC-Th17 axis may be an important pathway in the treatment of AR. ITE, a nontoxic AhR ligand, attenuated the Th17 response; thus, it appears to be a promising therapeutic candidate for suppressing the inflammatory responses associated with AR.
Post, Robert E; Jamena, Gemma P; Gamble, James D
2014-09-01
Precept-Assist® (PA) is a computer-based program developed by the Virtua Family Medicine Residency where residents receive a score on a Likert-type scale from an attending for each precept based on their knowledge base. The purpose of this study was to attempt to validate this program for precepting family medicine residents. This was a validation study. PA and American Board of Family Medicine (ABFM) In-Training Exam (ITE) scores for all residents from a community-based family medicine residency between the years 2002 and 2011 were included (n=216). Pearson correlation coefficients were calculated between PA scores for the second quarter of the academic year (October 1 to December 31) and scores on the ITE. An ROC curve was also created to determine sensitivity and specificity for various PA scores in predicting residents scoring 500 or above on the ITE. The PA mean (SD) score was 5.18 (0.84) and the ITE mean (SD) score was 425.1 (87.6). The Pearson correlation coefficient between PA and ITE scores was 0.55, which is a moderately positive correlation. The AUC of the ROC curve was 0.783 (95% CI 0.704-0.859). A PA score of 5.5 (between the level of a PGY-2 and PGY-3) was 72% sensitive and 77% specific for scoring 500 or above on the ITE with a positive LR of 3.12. There is a significant correlation between PA scores and ABFM In-Training Exam scores. PA is a valid screening tool that can be used as a predictor for future performance in Family Medicine In-Training exams.
Genome-wide transcriptional profiling of human glioblastoma cells in response to ITE treatment
Kang, Bo; Zhou, Yanwen; Zheng, Min; Wang, Ying-Jie
2015-01-01
A ligand-activated transcription factor aryl hydrocarbon receptor (AhR) is recently revealed to play a key role in embryogenesis and tumorigenesis (Feng et al. [1], Safe et al. [2]) and 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) (Song et al. [3]) is an endogenous AhR ligand that possesses anti-tumor activity. In order to gain insights into how ITE acts via the AhR in embryogenesis and tumorigenesis, we analyzed the genome-wide transcriptional profiles of the following three groups of cells: the human glioblastoma U87 parental cells, U87 tumor sphere cells treated with vehicle (DMSO) and U87 tumor sphere cells treated with ITE. Here, we provide the details of the sample gathering strategy and show the quality controls and the analyses associated with our gene array data deposited into the Gene Expression Omnibus (GEO) under the accession code of GSE67986. PMID:26484269
Tryptophan derivatives regulate the transcription of Oct4 in stem-like cancer cells.
Cheng, Jie; Li, Wenxin; Kang, Bo; Zhou, Yanwen; Song, Jiasheng; Dan, Songsong; Yang, Ying; Zhang, Xiaoqian; Li, Jingchao; Yin, Shengyong; Cao, Hongcui; Yao, Hangping; Zhu, Chenggang; Yi, Wen; Zhao, Qingwei; Xu, Xiaowei; Zheng, Min; Zheng, Shusen; Li, Lanjuan; Shen, Binghui; Wang, Ying-Jie
2015-06-10
The aryl hydrocarbon receptor (AhR), a ligand-activated transcription factor that responds to environmental toxicants, is increasingly recognized as a key player in embryogenesis and tumorigenesis. Here we show that a variety of tryptophan derivatives that act as endogenous AhR ligands can affect the transcription level of the master pluripotency factor Oct4. Among them, ITE enhances the binding of the AhR to the promoter of Oct4 and suppresses its transcription. Reduction of endogenous ITE levels in cancer cells by tryptophan deprivation or hypoxia leads to Oct4 elevation, which can be reverted by administration with synthetic ITE. Consequently, synthetic ITE induces the differentiation of stem-like cancer cells and reduces their tumorigenic potential in both subcutaneous and orthotopic xenograft tumour models. Thus, our results reveal a role of tryptophan derivatives and the AhR signalling pathway in regulating cancer cell stemness and open a new therapeutic avenue to target stem-like cancer cells.
Tryptophan derivatives regulate the transcription of Oct4 in stem-like cancer cells
Cheng, Jie; Li, Wenxin; Kang, Bo; Zhou, Yanwen; Song, Jiasheng; Dan, Songsong; Yang, Ying; Zhang, Xiaoqian; Li, Jingchao; Yin, Shengyong; Cao, Hongcui; Yao, Hangping; Zhu, Chenggang; Yi, Wen; Zhao, Qingwei; Xu, Xiaowei; Zheng, Min; Zheng, Shusen; Li, Lanjuan; Shen, Binghui; Wang, Ying-Jie
2015-01-01
The aryl hydrocarbon receptor (AhR), a ligand-activated transcription factor that responds to environmental toxicants, is increasingly recognized as a key player in embryogenesis and tumorigenesis. Here we show that a variety of tryptophan derivatives that act as endogenous AhR ligands can affect the transcription level of the master pluripotency factor Oct4. Among them, ITE enhances the binding of the AhR to the promoter of Oct4 and suppresses its transcription. Reduction of endogenous ITE levels in cancer cells by tryptophan deprivation or hypoxia leads to Oct4 elevation, which can be reverted by administration with synthetic ITE. Consequently, synthetic ITE induces the differentiation of stem-like cancer cells and reduces their tumorigenic potential in both subcutaneous and orthotopic xenograft tumour models. Thus, our results reveal a role of tryptophan derivatives and the AhR signalling pathway in regulating cancer cell stemness and open a new therapeutic avenue to target stem-like cancer cells. PMID:26059097
Exercise training improves autonomic profiles in patients with Charcot-Marie-Tooth disease.
El Mhandi, Lhassan; Pichot, Vincent; Calmels, Paul; Gautheron, Vincent; Roche, Frédéric; Féasson, Léonard
2011-11-01
The effect of an interval exercise training (ITE) program on heart rate variability (HRV) was studied in 8 patients with Charcot-Marie-Tooth (CMT) disease and 8 healthy controls. At baseline, all subjects underwent ambulatory 24-hour Holter electrocardiographic (ECG) monitoring to evaluate HRV. HRV analysis was repeated on CMT patients after they completed a 24-week ITE program on a cycle ergometer. Before exercise, all HRV indices were lower in patients compared with controls, and the difference reached statistical significance for pNN50 (percent of differences between adjacent R-R intervals exceeding 50 ms). After ITE, time- and frequency-domain indices were significantly improved, particularly at night (+8% mean R-R interval, +95% pNN50, 52% reduction in low/high-frequency ratio). We observed significant increases in some of the time and frequency parameters, and values sometimes exceeded those of controls at baseline. Our results suggest that ITE improves HRV modulation in CMT patients by enhancing parasympathetic activity. Copyright © 2011 Wiley Periodicals, Inc.
Effect of plastic-covered ultrasonic scalers on titanium implant surfaces.
Mann, M; Parmar, D; Walmsley, A D; Lea, S C
2012-01-01
Maintaining oral health around titanium implants is essential. The formation of a biofilm on the titanium surface will influence the continuing success of the implant. These concerns have led to modified ultrasonic scaler instruments that look to reduce implant damage while maximising the cleaning effect. This study aimed to assess the effect of instrumentation, with traditional and modified ultrasonic scalers, on titanium implant surfaces and to correlate this with the oscillations of the instruments. Two ultrasonic insert designs (metallic TFI-10 and a plastic-tipped implant insert) were selected. Each scaler probe was scanned using a scanning laser vibrometer, under loaded and unloaded conditions, to determine their oscillation characteristics. Loads were applied against a titanium implant (100g and 200 g) for 10 s. The resulting implant surfaces were then scanned using laser profilometry and scanning electron microscopy (SEM). Insert probes oscillated with an elliptical motion with the maximum amplitude at the probe tip. Laser profilometry detected defects in the titanium surface only for the metallic scaler insert. Defect widths at 200 g high power were significantly larger than all other load/power conditions (P<0.02). Using SEM, it was observed that modifications to the implant surface had occurred following instrumentation with the plastic-tipped insert. Debris was also visible around the defects. Metal scalers produce defects in titanium implant surfaces and load and power are important factors in the damage caused. Plastic-coated scaler probes cause minimal damage to implant surfaces and have a polishing action but can leave plastic deposits behind on the implant surface. © 2011 John Wiley & Sons A/S.
In-plane ultrasonic needle tracking using a fiber-optic hydrophone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial
Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less
NASA Astrophysics Data System (ADS)
Hormazabal, Samuel; Morales, Carmen; Cornejo, Marcela; Bento, Joaquim; Valencia, Luis; Auger, Pierre; Rodriguez, Angel; Correa, Marco; Anabalón, Valeria; Silva, Nelson
2016-04-01
In the Southeast Pacific, oceanographic processes that sustain the biological production necessary to maintain the ecosystems associated to seamounts and oceanic islands are still poorly understood. Recent studies suggest that the interaction of mesoscale and submesoescale eddies with oceanic islands and seamounts could be playing an important role in the time-space variability of primary production. In this work, research cruises, satellite data and Regional Ocean Modeling System (ROMS) results have been used to describe the main characteristics of intrathermocline eddies (ITE) and their impact on the Juan Fernández archipelago (JFA), off central Chile. The JFA is located off the coast of central Chile (33°S), and is composed of three main islands: Robinson Crusoe (RC), Alejandro Selkirk (AS) and Santa Clara (SC). Between the RC and AS are located the westernmost seamounts (JF6 and JF5) of the Juan Fernández archipelago. Satellite altimetry data (sea surface height from AVISO) were used to detect and track mesoscale eddies through eddy-tracking algorithm. Physical, chemical and biological parameters as temperature, salinity, dissolved oxygen and fluorescence were measured in the water column at JF5 and JF6, and along the coast off central Chile (30-40°S). Results from the research cruise exhibit the interaction between an ITE and the seamount JF6. Eddy-tracking results showed that the ITE observed at the JF6 was formed at the coast off central-southern Chile, traveled ~900 km seaward and after ~9 months reached the JF5 and JF6 region. Observations along the Chilean coast confirmed that the coast corresponds to the formation area of the observed ITE. In this region, ITEs are represented by subsurface lenses (~100 km diameter; 400 m thickness) of homogeneous salinity, nutrient rich and oxygen-poor equatorial subsurface water mass (ESSW) which is transported poleward by the Peru-Chile undercurrent in the coastal band and seaward by ITEs. The effect of ITEs on the ecosystem productivity around the Juan Fernández archipelago (JFA) is discussed.
NASA Astrophysics Data System (ADS)
Wegrzecka, Iwona; Wegrzecki, Maciej
1999-04-01
The design and properties of 3 mm silicon avalanche photodiodes developed at ITE are presented. Their performance parameters within the spectral range applicable in scintillation detection (400-700 nm) are discussed and compared to those for near infrared radiation.
Aspheric surface testing by irradiance transport equation
NASA Astrophysics Data System (ADS)
Shomali, Ramin; Darudi, Ahmad; Nasiri, Sadollah; Asgharsharghi Bonab, Armir
2010-10-01
In this paper a method for aspheric surface testing is presented. The method is based on solving the Irradiance Transport Equation (ITE).The accuracy of ITE normally depends on the amount of the pick to valley of the phase distribution. This subject is investigated by a simulation procedure.
Siddiqui, EJ; Ali, S; Koneru, S
2006-01-01
INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424
Mantle-derived trace element variability in olivines and their melt inclusions
NASA Astrophysics Data System (ADS)
Neave, David A.; Shorttle, Oliver; Oeser, Martin; Weyer, Stefan; Kobayashi, Katsura
2018-02-01
Trace element variability in oceanic basalts is commonly used to constrain the physics of mantle melting and the chemistry of Earth's deep interior. However, the geochemical properties of mantle melts are often overprinted by mixing and crystallisation processes during ascent and storage. Studying primitive melt inclusions offers one solution to this problem, but the fidelity of the melt-inclusion archive to bulk magma chemistry has been repeatedly questioned. To provide a novel check of the melt inclusion record, we present new major and trace element analyses from olivine macrocrysts in the products of two geographically proximal, yet compositionally distinct, primitive eruptions from the Reykjanes Peninsula of Iceland. By combining these macrocryst analyses with new and published melt inclusion analyses we demonstrate that olivines have similar patterns of incompatible trace element (ITE) variability to the inclusions they host, capturing chemical systematics on intra- and inter-eruption scales. ITE variability (element concentrations, ratios, variances and variance ratios) in olivines from the ITE-enriched Stapafell eruption is best accounted for by olivine-dominated fractional crystallisation. In contrast, ITE variability in olivines and inclusions from the ITE-depleted Háleyjabunga eruption cannot be explained by crystallisation alone, and must have originated in the mantle. Compatible trace element (CTE) variability is best described by crystallisation processes in both eruptions. Modest correlations between host and inclusion ITE contents in samples from Háleyjabunga suggest that melt inclusions can be faithful archives of melting and magmatic processes. It also indicates that degrees of ITE enrichment can be estimated from olivines directly when melt inclusion and matrix glass records of geochemical variability are poor or absent. Inter-eruption differences in olivine ITE systematics between Stapafell and Háleyjabunga mirror differences in melt inclusion suites, and confirm that the Stapafell eruption was fed by lower degree melts from greater depths within the melting region than the Háleyjabunga eruption. Although olivine macrocrysts from Stapafell are slightly richer in Ni than those from Háleyjabunga, their overall CTE systematics (e.g., Ni/(Mg/Fe), Fe/Mn and Zn/Fe) are inconsistent with being derived from olivine-free pyroxenites. However, the major element systematics of Icelandic basalts require lithological heterogeneity in their mantle source in the form of Fe-rich and hence fusible domains. We thus conclude that enriched heterogeneities in the Icelandic mantle are composed of modally enriched, yet nonetheless olivine-bearing, lithologies and that olivine CTE contents provide an incomplete record of lithological heterogeneity in the mantle. Modally enriched peridotites may therefore play a more important role in oceanic magma genesis than previously inferred.
Dong, Guo-Chung; Chiu, Li-Chen; Ting, Chien-Kun; Hsu, Jia-Ruei; Huang, Chih-Chung; Chang, Yin; Chen, Gin-Shin
2017-09-01
Ultrasound guidance for epidural block has improved clinical blind-trial problems but the design of present ultrasonic probes poses operating difficulty of ultrasound-guided catheterization, increasing the failure rate. The purpose of this study was to develop a novel ultrasonic probe to avoid needle contact with vertebral bone during epidural catheterization. The probe has a central circular passage for needle insertion. Two focused annular transducers are deployed around the passage for on-axis guidance. A 17-gauge insulated Tuohy needle containing the self-developed fiber-optic-modified stylet was inserted into the back of the anesthetized pig, in the lumbar region under the guidance of our ultrasonic probe. The inner transducer of the probe detected the shallow echo signals of the peak-peak amplitude of 2.8 V over L3 at the depth of 2.4 cm, and the amplitude was decreased to 0.8 V directly over the L3 to L4 interspace. The outer transducer could detect the echoes from the deeper bone at the depth of 4.5 cm, which did not appear for the inner transducer. The operator tilted the probe slightly in left-right and cranial-caudal directions until the echoes at the depth of 4.5 cm disappeared, and the epidural needle was inserted through the central passage of the probe. The needle was advanced and stopped when the epidural space was identified by optical technique. The needle passed without bone contact. Designs of the hollow probe for needle pass and dual transducers with different focal lengths for detection of shallow and deep vertebrae may benefit operation, bone/nonbone identification, and cost.
NASA Technical Reports Server (NTRS)
Fischell, D. R.; Mazique, J. C. (Inventor)
1981-01-01
A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance.
Associations of conference attendance with internal medicine in-training examination scores.
McDonald, Furman S; Zeger, Scott L; Kolars, Joseph C
2008-04-01
To examine the association of medical knowledge acquisition with attendance at specific conference types during internal medicine residency. Attendance at residency core curriculum, morbidity and mortality, and medical grand rounds conferences was tracked for 195 residents who took the Internal Medicine In-Training Examination (IM-ITE) 421 times while attending the Internal Medicine Residency Program at Mayo Clinic's site in Rochester, MN, between October 1, 1999, and October 1, 2003. Random effects modeling was used to adjust for variables known or hypothesized to be associated with IM-ITE scores and allowed discrimination of effects of individual conferences on IM-ITE scores. Total conference attendance was significantly associated with increased IM-ITE scores, with cohort mean increase of 2.30% (95% confidence interval [CI], 1.24% to 3.36%; P<.001). Core curriculum conferences accounted for much more of this association than either medical grand rounds or morbidity and mortality, with cohort mean increases of 2.05% (95% CI, 0.13% to 3.90%; P=.04), 0.24% (95% CI, -0.56% to 1.03%; P=.61), and 0.03% (95% CI, -1.69% to 1.69%; P=.97), respectively. Conference attendance is associated with improved knowledge acquisition as measured by improved performance on IM-ITE. This finding does not appear to apply to all conferences at our institution but rather is specifically attributable to attendance at the core curriculum series.
Making the Grade: Describing Inherent Requirements for the Initial Teacher Education Practicum
ERIC Educational Resources Information Center
Sharplin, Elaine; Peden, Sanna; Marais, Ida
2016-01-01
This study explores the development, description, and illustration of inherent requirement (IR) statements to make explicit the requirements for performance on an initial teacher education (ITE) practicum. Through consultative group processes with stakeholders involved in ITE, seven IR domains were identified. From interviews with academics,…
Rethinking the Practicum: Limitations and Possibilities
ERIC Educational Resources Information Center
Grudnoff, Lexie
2011-01-01
Teachers and policy makers often view the practicum as being the critical component of initial teacher education (ITE) programmes. While numerous studies have investigated the practicum in ITE, less attention has been given to the role practicum plays in the transition from preparation to teaching. This study investigated 12 New Zealand first-year…
Changing Science Teaching Practice in Early Career Secondary Teaching Graduates
ERIC Educational Resources Information Center
Bartholomew, Rex; Moeed, Azra; Anderson, Dayle
2011-01-01
Initial teacher education (ITE) is being challenged internationally to prepare teachers with the understandings needed to teach an increasingly diverse student population. Science teachers need to prepare students with both conceptual and procedural understanding. The challenge is to prioritise a balance in ITE courses between theoretical…
Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi
2016-07-01
This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.
Phoenix Conductivity Probe with Shadow and Toothmark
NASA Technical Reports Server (NTRS)
2008-01-01
NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 after the probe was lifted away from the soil. The imprint left by the insertion is visible below the probe, and a shadow showing the probe's four needles is cast on a rock to the left. The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.Reforming Initial Teacher Education: A Call for Innovation
ERIC Educational Resources Information Center
Yeigh, Tony; Lynch, David
2017-01-01
A variety of public critiques, reports and government reviews into Initial Teacher Education (ITE) in Australia and globally have called for a rethink on teacher education. Similarly, key researchers such as Hattie (2011), Smith and Lynch (2010) and Ingvarson et al. (2014) have argued for new, innovative approaches to ITE that are able to provide…
Volunteering within Initial Teacher Education: Factors That Boost and Block Participation
ERIC Educational Resources Information Center
Forster, Daniella J.; Archer, Jennifer; Tajin, Rukhsana T.
2015-01-01
Voluntary professional experience can be a powerful way for initial teacher education (ITE) students to develop an understanding of schools and their communities. Do ITE students make use of these opportunities? There is little Australian research that explores genuine volunteering that does not "require" students to engage with the…
"Elite" Career-Changers and Their Experience of Initial Teacher Education
ERIC Educational Resources Information Center
Wilkins, Chris
2017-01-01
This study explores the motivation of "high-status" professionals to change career and enter teaching, and their experience of undertaking initial teacher education (ITE) programmes in England. The study builds on previous research which found that career-changers are disproportionately more likely to fail to complete their ITE studies,…
Picturebooks in Teacher Education: Eight Teacher Educators Share Their Practice
ERIC Educational Resources Information Center
Daly, Nicola; Blakeney-Williams, Marilyn M.
2015-01-01
There is a great deal of contemporary research demonstrating the effective use of picturebooks in the classroom; however, there are few studies recording perceptions and use of picturebooks in Initial Teacher Education [ITE]. This study explores the reported use of picturebooks within a New Zealand university-based ITE degree programme. The data…
Can a Competence or Standards Model Facilitate an Inclusive Approach to Teacher Education?
ERIC Educational Resources Information Center
Moran, Anne
2009-01-01
The paper seeks to determine whether programmes of initial teacher education (ITE) can contribute to the development of beginning teachers' inclusive attitudes, values and practices. The majority of ITE programmes are based on government prescribed competence or standards frameworks, which are underpinned by Codes of Professional Values. It is…
Curriculum of Initial Teacher Education in Portugal: New Contexts, Old Problems
ERIC Educational Resources Information Center
Flores, Maria Assuncao
2011-01-01
Initial teacher education (ITE) has attracted the attention of many researchers worldwide aiming at discussing its curriculum and rationale, but essentially its impact on the education and professional socialisation of pre-service teachers. This paper looks at the major trends in the recent ITE curriculum in the Portuguese context, as a…
Levels of Critical Thinking of Secondary Agriculture Students.
ERIC Educational Resources Information Center
Rollins, Timothy J.
1990-01-01
A total of 668 Iowa secondary agriculture students completed the Cornell Critical Thinking Test Level X. These scores and data from the Iowa Tests of Educational Development (ITED) revealed levels of proficiency comparable to other high school populations. The best indicator of critical thinking score was the ITED subtest Reading Total. (SK)
Spring Seminars Report. Information Technology and Education Programme. Occasional Paper ITE/3/85.
ERIC Educational Resources Information Center
Lewis, R.
This report contains excerpts from papers and summaries of discussions and program actions carried out during a series of seminars held to establish research priorities under the Information Technology and Education Programme (ITE) in the United Kingdom. The seminar on "Information Technology" (IT) included Kenneth Ruthven's…
Relationship of Elementary and Secondary School Achievement Test Scores to Later Academic Success.
ERIC Educational Resources Information Center
Loyd, Brenda H.; And Others
1980-01-01
This study investigated the relationship between achievement test scores on the Iowa Tests of Basic Skills (ITBS) and Iowa Tests of Educational Development (ITED), and high school and college grade point average. Support for the predictive validity of the ITBS and ITED achievement test batteries is provided. (Author/GK)
New Models for Initial Teacher Education in Scotland
ERIC Educational Resources Information Center
Kibble, Bob
2012-01-01
In this article, the author responds to the recent article by Lynne Bianchi commenting on the Donaldson report, "Teaching Scotland's future" (Donaldson, 2011). He agrees that the Donaldson report has indeed been a catalyst to drive change across the entire landscape of initial teacher education (ITE) in Scotland. In fact, not only ITE:…
The Meaning and Utility of Institutional Teaching Evaluations
ERIC Educational Resources Information Center
East, Katheryn
2015-01-01
This study analyzes end of course institutional teaching evaluations (ITEs) done anonymously by students in a pre-service teacher education course over a 15-year span. The purpose was to determine if and how the ITE findings might inform practice and relate to teaching metaphors as a tool of study. Analysis revealed: (a) teacher effectiveness…
A Biographical Experience of Teacher Education in Aotearoa New Zealand
ERIC Educational Resources Information Center
O'Neill, John
2017-01-01
The article analyses initial teacher education (ITE) policy and practice in Aotearoa New Zealand over forty years. Central to the local ITE context was the incorporation of the "monotechnic" colleges of teacher education into the university sector in the 1990s and 2000s, following New Zealand's structural adjustments to the state…
ERIC Educational Resources Information Center
Harlow, Ann; Cobb, Donella J.
2014-01-01
This paper reports on the findings of a reconceptualised Initial Teacher Education (ITE) programme where a collaborative relationship between the university and partner schools saw the shared responsibility for the first year ITE programme. Findings from this study suggests that ongoing, authentic teaching experiences in collaboration with…
Ha, Duc; Faulx, Michael; Isada, Carlos; Kattan, Michael; Yu, Changhong; Olender, Jeff; Nielsen, Craig; Brateanu, Andrei
2014-01-01
Background The academic half-day (AHD) curriculum is an alternative to the traditional noon conference in graduate medical education, yet little is known regarding its effect on knowledge acquisition and resident satisfaction. Objective We investigated the association between the 2 approaches for delivering the curriculum and knowledge acquisition, as reflected by the Internal Medicine In-Training Examination (IM-ITE) scores and assessed resident learning satisfaction under both curricula. Methods The Cleveland Clinic Internal Medicine Residency Program transitioned from the noon conference to the AHD curriculum in 2011. Covariates for residents enrolled from 2004 to 2011 were age; sex; type of medical degree; United States Medical Licensing Examination Step 1, 2 Clinical Knowledge; and IM-ITE-1 scores. We performed univariable and multivariable linear regressions to investigate the association between covariates and IM-ITE-2 and IM-ITE-3 scores. Residents also were surveyed about their learning satisfaction in both curricula. Results Of 364 residents, 112 (31%) and 252 (69%) were exposed to the AHD and the noon conference curriculum, respectively. In multivariable analyses, the AHD curriculum was associated with higher IM-ITE-3 (regression coefficient, 4.8; 95% confidence interval 2.9–6.6) scores, and residents in the AHD curriculum had greater learning satisfaction compared with the noon conference cohort (Likert, 3.4 versus 3.0; P = .003). Conclusions The AHD curriculum was associated with improvement in resident medical knowledge acquisition and increased learner satisfaction. PMID:24701317
Ha, Duc; Faulx, Michael; Isada, Carlos; Kattan, Michael; Yu, Changhong; Olender, Jeff; Nielsen, Craig; Brateanu, Andrei
2014-03-01
The academic half-day (AHD) curriculum is an alternative to the traditional noon conference in graduate medical education, yet little is known regarding its effect on knowledge acquisition and resident satisfaction. We investigated the association between the 2 approaches for delivering the curriculum and knowledge acquisition, as reflected by the Internal Medicine In-Training Examination (IM-ITE) scores and assessed resident learning satisfaction under both curricula. The Cleveland Clinic Internal Medicine Residency Program transitioned from the noon conference to the AHD curriculum in 2011. Covariates for residents enrolled from 2004 to 2011 were age; sex; type of medical degree; United States Medical Licensing Examination Step 1, 2 Clinical Knowledge; and IM-ITE-1 scores. We performed univariable and multivariable linear regressions to investigate the association between covariates and IM-ITE-2 and IM-ITE-3 scores. Residents also were surveyed about their learning satisfaction in both curricula. Of 364 residents, 112 (31%) and 252 (69%) were exposed to the AHD and the noon conference curriculum, respectively. In multivariable analyses, the AHD curriculum was associated with higher IM-ITE-3 (regression coefficient, 4.8; 95% confidence interval 2.9-6.6) scores, and residents in the AHD curriculum had greater learning satisfaction compared with the noon conference cohort (Likert, 3.4 versus 3.0; P = .003). The AHD curriculum was associated with improvement in resident medical knowledge acquisition and increased learner satisfaction.
Wu, Yanming; Chen, Xiao; Zhou, Qian; He, Qizhi; Kang, Jiuhong; Zheng, Jing; Wang, Kai; Duan, Tao
2014-01-01
Vascular remodeling in the placenta is essential for normal fetal development. The previous studies have demonstrated that in utero exposure to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD, an environmental toxicant) induces the intrauterine fetal death in many species via the activation of aryl hydrocarbon receptor (AhR). In the current study, we compared the effects of 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) and TCDD on the vascular remodeling of rat placentas. Pregnant rats on gestational day (GD) 15 were randomly assigned into 5 groups, and were exposed to a single dose of 1.6 and 8.0 mg/kg body weight (bw) ITE, 1.6 and 8.0 µg/kg bw TCDD, or an equivalent volume of the vehicle, respectively. The dams were sacrificed on GD20 and the placental tissues were gathered. The intrauterine fetal death was observed only in 8.0 µg/kg bw TCDD-exposed group and no significant difference was seen in either the placental weight or the fetal weight among all these groups. The immunohistochemical and histological analyses revealed that as compared with the vehicle-control, TCDD, but not ITE, suppressed the placental vascular remodeling, including reduced the ratio of the placental labyrinth zone to the basal zone thickness (at least 0.71 fold of control), inhibited the maternal sinusoids dilation and thickened the trophoblastic septa. However, no marked difference was observed in the density of fetal capillaries in the labyrinth zone among these groups, although significant differences were detected in the expression of angiogenic growth factors between ITE and TCDD-exposed groups, especially Angiopoietin-2 (Ang-2), Endoglin, Interferon-γ (IFN-γ) and placenta growth factor (PIGF). These results suggest ITE and TCDD differentially regulate the vascular remodeling of rat placentas, as well as the expression of angiogenic factors and their receptors, which in turn may alter the blood flow in the late gestation and partially resulted in intrauterine fetal death.
Kuvin, Jeffrey T; Soto, Amanda; Foster, Lauren; Dent, John; Kates, Andrew M; Polk, Donna M; Rosenzweig, Barry; Indik, Julia
2015-03-31
The American College of Cardiology (ACC), in collaboration with the National Board of Medical Examiners (NBME), developed the first standardized in-training examination (ITE) for cardiovascular disease fellows-in-training (FITs). In addition to testing knowledge, this examination uses the newly developed ACC Curricular Milestones to provide specific, competency-based feedback to program directors and FITs. The ACC ITE has been administered more than 5,000 times since 2011. This analysis sought to report the initial experience with the ITE, including feasibility and reliability of test development and implementation, as well as the ability of this process to provide useful feedback in key content areas. The annual ACC ITE has been available to cardiovascular disease fellowship programs in the United States since 2011. Questions for this Web-based, secure, multiple-choice examination were developed by a group of cardiovascular disease specialists and each question was analyzed by the NBME to ensure quality. Scores were equated and standardized to allow for comparability. Trainees and program directors were provided detailed feedback, including a list of the curricular competencies tested by those questions answered incorrectly. The ITE was administered 5,118 times. In 2013, the examination was taken by 1,969 fellows, representing 194 training programs. Among the 3 training years, there was consistency in the examination scores. Total test scores and scores within each of the content areas increased with each FIT year (there was a statistically significant difference in each cohort's average scale score across administration years). There was also significant improvement in examination scores across the fellowship years. The ACC ITE is a powerful tool available to all training programs to assess medical knowledge. This examination also delivers robust and timely feedback addressing individual knowledge gaps, and thus, may serve as a basis for improving training curricula. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Font, Eric; Carlut, Julie; Rémazeilles, Céline; Mather, Tamsin; Nédélec, Anne; Mirão, José; Casale, Sandra
2017-04-01
Recently, we identified an enigmatic chlorine-rich iron (oxyhydr)oxide, together with mercury anomalies in End-Cretaceous marine sediments coeval with major eruptions of the Deccan Traps Magmatic Province. The mineral was observed in two remote sections, the Bidart section from the Basque-Cantabric Basin in the Atlantic Ocean, and the Gubbio (Bottacione) section in the Tethys realm, suggesting a global or at least widespread phenomenon. However, the exact nature and origin of this Cl-bearing mineral remained enigmatic. Here we present new results from the Bidart and Zumaya section, in the Basque Cantabric Basin, France and Spain. Micro-Raman analysis, Transmission (TEM) and Scanning (SEM) Electron Microscopy on Focused Ion Beam (FIB) foils were used in order to identify the accurate composition and nanostructure of the chlorine-rich mineral. Our results confirm akaganéite (β-FeOOH) as the main phase, with chlorine content of 3-5% of the total atomic weight. Our high-resolution TEM observations reveal that the micrometric-scale akaganéite particles are constituted by the aggregation of nanoparticles (nanorods) of akaganéite. Their internal structures contain empty spaces, suggesting formation in a low-density environment. Based on this new mineralogical evidence, we propose that the observed akaganéite was formed at low temperature and high altitude in the Deccan volcanic plume and was further transported to Bidart, Zumaya and Gubbio (where presence of akaganeite is inferred based on the similarity of the Cl-bearing minerals to the Bidart material) through the stratosphere. Therefore, akaganéite provides a potential new sedimentary marker to identify the imprint of the Deccan eruptions in the global stratigraphic record and is evidence of the broad distribution of volcanic halogen species at the start of the Cretaceous-Tertiary mass extinction. Publication supported by FCT- project UID/GEO/50019/2013 - Instituto Dom Luiz
Iglar, Karl; Murdoch, Stuart; Meaney, Christopher; Krueger, Paul
2018-01-01
To determine the number of patient visits, patient demographic information, and diagnoses in an urban ambulatory care setting in a family medicine residency program, and assess the correlation between the number of patient visits and residents' in-training examination (ITE) scores. Retrospective analysis of data from resident practice profiles, electronic medical records, and residents' final ITE scores. Family medicine teaching unit in a community hospital in Barrie, Ont. Practice profile data were from family medicine residents enrolled in the program from July 1, 2013, to June 30, 2014, and electronic medical record and ITE data were from those enrolled in the program from July 1, 2010, to June 30, 2015. Number of patient visits, patient characteristics (eg, sex, age), priority topics addressed in clinic, resident characteristics (eg, age, sex, level of residency), and residents' final ITE scores. Between July 1, 2013, and June 30, 2014, there were 11 115 patient visits. First-year residents had a mean of 5.48 patient visits per clinic, and second-year residents had a mean of 5.98 patient visits per clinic. A Pearson correlation coefficient of 0.68 was found to exist between the number of patients seen and the final ITE scores, with a 10.5% difference in mean score between residents who had 1251 or more visits and those who had 1150 or fewer visits. Three diagnoses (ie, epistaxis, meningitis, and neck pain) deemed important for Certification by the College of Family Physicians of Canada were not seen by any of the residents in clinic. There is a moderate correlation between the number of patients seen by residents in ambulatory care and ITE scores in family medicine. It is important to assess patients' demographic information and diagnoses made in resident practices to ensure an adequate clinical experience. Copyright© the College of Family Physicians of Canada.
Vlastarakos, P V; Nikolopoulos, T P; Manolopoulos, L; Stamou, A; Halkiotis, K K; Ferekidis, E; Georgiou, E
2012-01-01
To quantify the bystander-effect of 2.5G mobile telephones (2.5G-MTs) on the speech perception of digital hearing-aid (dHA) users. Differences in the susceptibility of behind-the-ear (BTE) compared to in-to-the-ear (ITE) dHAs were also assessed. Prospective-comparative study conducted at a tertiary referral centre (ENT Department) and a HA-fitting laboratory. Key-word recognition scores from open-sentence lists were calculated. Power-analysis determined that a minimum of 60 subjects with SNHL (30 in each group), using either BTE or ITE dHAs, were required for reliable study outcomes. Sixty-four adults were tested with a functioning 2.5G-MT at almost physical contact with their ear; thirty subjects used BTE and 34 ITE dHAs. Aided word recognition score differences between studied groups and within each group, while a 2.5G-MT was activated. Cut-off inclusion criterion regarding baseline aided word recognition score was 75%. Baseline aided word recognition scores for ITE dHAs were better compared to BTE ones (p < 0.01). Following the 2.5G-MT activation, this difference disappeared. No statistically significant difference in word recognition was observed between the examined groups, or within the BTE group, from the bystander-effect of the 2.5G-MT. ITE dHAs proved more susceptible to electromagnetic interference (p < 0.05). The bystander-effect of 2.5G-MTs on the speech perception of dHA users is either minimal, or not significant. The observed compatibility has a positive impact on the lives of millions of people worldwide. The long-standing theory of more interference in BTE compared to ITE HAs is not confirmed by the results of the present study. EBM level of evidence: 2c.
A Thesaurus for Information Technology and Education. Occasional Paper ITE/6/86.
ERIC Educational Resources Information Center
Lewis, R.
Prepared for use by the Information Technology and Education (ITE) Programme of the Economic and Social Science Research Council (ESRC), this draft document is based on the 1984 EUDISED (European Documentation and Information System for Education) Thesaurus for Information Processing. This draft is a modified thesaurus which aims to keep as close…
Developing a Curriculum for Initial Teacher Education Using a Situated Learning Perspective
ERIC Educational Resources Information Center
Skinner, Nigel
2010-01-01
This paper argues that the implications of the concept of situated learning are important when developing a curriculum for initial teacher education (ITE). It describes and analyses the use of a model of ITE designed to stimulate discussions promoting the development of professional craft knowledge situated mainly in schools and to connect these…
IT Implementation in ITE in the Limpopo Province (South Africa): A Dream or Reality?
ERIC Educational Resources Information Center
Monobe, Ratau John
2011-01-01
This paper describes the results of a survey about the most critical issues facing the implementation of IT (information technology) ITE (initial teacher education) in all the HBUs (historically black universities) in the Limpopo Province of South Africa. Over 250 responses were received and both universities in the Limpopo Province were…
Flexible deep brain neural probes based on a parylene tube structure
NASA Astrophysics Data System (ADS)
Zhao, Zhiguo; Kim, Eric; Luo, Hao; Zhang, Jinsheng; Xu, Yong
2018-01-01
Most microfabricated neural probes have limited shank length, which prevents them from reaching many deep brain structures. This paper reports deep brain neural probes with ultra-long penetrating shanks based on a simple but novel parylene tube structure. The mechanical strength of the parylene tube shank is temporarily enhanced during implantation by inserting a metal wire. The metal wire can be removed after implantation, making the implanted probe very flexible and thus minimizing the stress caused by micromotions of brain tissues. Optogenetic stimulation and chemical delivery capabilities can be potentially integrated by taking advantage of the tube structure. Single-shank prototypes with a shank length of 18.2 mm have been developed. The microfabrication process comprises of deep reactive ion etching (DRIE) of silicon, parylene conformal coating/refilling, and XeF2 isotropic silicon etching. In addition to bench-top insertion characterization, the functionality of developed probes has been preliminarily demonstrated by implanting into the amygdala of a rat and recording neural signals.
Phoenix Conductivity Probe Inserted into Martian Soil
NASA Technical Reports Server (NTRS)
2008-01-01
NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Robotic Arm Camera on Phoenix took this image on the morning of Sol 99 while the probe's needles were in the ground. The science team informally named this soil target 'Gandalf.' The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.Fiber-optic temperature probe system for inner body
NASA Astrophysics Data System (ADS)
Liu, Bo; Deng, Xing-Zhong; Cao, Wei; Cheng, Xianping; Xie, Tuqiang; Zhong, Zugen
1991-08-01
The authors have designed a fiber-optic temperature probe system that can quickly insert its probe into bodies to measure temperature. Its thermometer unit has the function of program- controlled zeroing. The single-chip microcomputer is used to control the whole system and process data. The sample system has been tested in a coal furnace.
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2011 CFR
2011-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2014 CFR
2014-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
16 CFR 1505.51 - Hot surfaces.
Code of Federal Regulations, 2012 CFR
2012-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
Conductivity Probe Inserted in Martian Soil, Sol 46
NASA Technical Reports Server (NTRS)
2008-01-01
This image taken by the Surface Stereo Imager on NASA's Phoenix Mars Lander shows the lander's Thermal and Electrical Conductivity Probe (TECP), at the end of the Robotic Arm, on the 46th Martian day, or sol, of the mission (July 11, 2008). The TECP is inserted at a site called Vestri, which was monitored several times over the course of the mission. The probe's measurements at this site yielded evidence that water was exchanged, daily and seasonally, between the soil and atmosphere. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.Deep Space Network capabilities for receiving weak probe signals
NASA Technical Reports Server (NTRS)
Asmar, Sami; Johnston, Doug; Preston, Robert
2004-01-01
This paper will describe the capability and highlight the cases of the critical communications for the Mars rovers and Saturn Orbit Insertion and preparation radio tracking of the Huygens probe at (non-DSN) radio telescopes.
Aligning Plasma-Arc Welding Oscillations
NASA Technical Reports Server (NTRS)
Norris, Jeff; Fairley, Mike
1989-01-01
Tool aids in alignment of oscillator probe on variable-polarity plasma-arc welding torch. Probe magnetically pulls arc from side to side as it moves along joint. Tensile strength of joint depends on alignment of weld bead and on alignment of probe. Operator installs new tool on front of torch body, levels it with built-in bubble glass, inserts probe in slot on tool, and locks probe in place. Procedure faster and easier and resulting alignment more accurate and repeatable.
ERIC Educational Resources Information Center
Diamond, Fleur; Parr, Graham; Bulfin, Scott
2017-01-01
Evidence has been accumulating for some time about the impact of standards-based education reforms on schools and schooling, but there has been little research investigating the influence of these reforms on university-based initial teacher education (ITE). This article critically inquiries into the effects of these reforms on an ITE co-teaching…
Measuring the contour of a wavefront using the Irradiance Transport Equation (ITE)
NASA Astrophysics Data System (ADS)
Castillo-Rodríguez, Luis; Granados-Agustín, Fermín; Fernández-Guasti, Manuel; Cornejo-Rodríguez, Alejandro
2006-01-01
The Irradiance Transport Equation (ITE), found by Teague, had been used in optics with different applications. One of the field where had been used is in optical testing, for example, with the method developed by Takeda. In this paper following the idea of using different optical and mathematical analysis method, theorical and experimental results are presented.
Chemotherapeutic Studies on Schistosomiasis.
1978-10-01
sick ’ wor m s posses sing little movement is evidence of possible activity requiring further testing. Untreated control animal s will norma lly show...be re- peated for confirmation . a ;‘~~~~. . t 4 . -.. -...~~~~~~~~~~~~ -.-- .~~ -- L ITE RAT U RE C ITED 1 . Radke , 11. G., Berrios- Duran , L. A
A Study on the Employee Turnover Antecedents in ITES/BPO Sector
ERIC Educational Resources Information Center
Sree Rekha, K. R.; Kamalanabhan, T. J.
2010-01-01
This paper aims at testing a conceptual model connecting variables of the internal and external work environment to ITES/BPO employee turnover. Based on the gaps identified from the literature that no single model explains in a comprehensive way as to why, people choose to leave and the lack of turnover studies on call centers located in India.…
Student Teachers' Perceptions of Poverty and Educational Achievement
ERIC Educational Resources Information Center
Thompson, Ian; McNicholl, Jane; Menter, Ian
2016-01-01
This paper reports on a mixed methods study carried out within the Initial Teacher Education (ITE) programme at the University of Oxford on the ways that the course sought to frame and address the link between poverty and poorer educational outcomes. The study was concerned with the views held by ITE students on the effects of poverty on pupils'…
ERIC Educational Resources Information Center
Dyment, Janet E.; Hill, Allen
2015-01-01
In this paper, we report on an investigation into initial teacher education students' (ITES) understandings of sustainability and the Australian National Curriculum Sustainability Cross Curricular Priority (CCP). We also explore their willingness and capacities to embed the CCP into their own teaching practices. The ITES (N = 392) completed a…
ERIC Educational Resources Information Center
Baker, William J.; Hunter, Mary Ann; Thomas, Sharon
2016-01-01
This article presents the findings of an investigation of eLearning & teaching in Arts education in Australian Initial Teacher Education (ITE) degrees. This project used survey and interviews to collect data from academics in 16 universities in 5 Australian states regarding their experiences of eLearning and Arts education. A rigorous and…
"I Never Heard the Word Methodology": Personal Accounts of Teacher Training in Ireland 1943-1980
ERIC Educational Resources Information Center
Walsh, Brendan
2017-01-01
This article examines the experiences of 27 retired secondary school teachers (respondents) who completed initial teacher education (ITE) courses between 1943 and 1980. The eldest respondent completed ITE in 1943 and the youngest in 1980. The timespan 1943-1980 is not purposeful but dependent on the cohort that volunteered to take part in the…
Performance of a Thermoelectric Device with Integrated Heat Exchangers
NASA Astrophysics Data System (ADS)
Barry, Matthew M.; Agbim, Kenechi A.; Chyu, Minking K.
2015-06-01
Thermoelectric devices (TEDs) convert heat directly into electrical energy, making them well suited for waste heat recovery applications. An integrated thermoelectric device (iTED) is a restructured TED that allows more heat to enter the p-n junctions, thus producing a greater power output . An iTED has heat exchangers incorporated into the hot-side interconnectors with flow channels directing the working fluid through the heat exchangers. The iTED was constructed of p- and n-type bismuth-telluride semiconductors and copper interconnectors and rectangular heat exchangers. The performance of the iTED in terms of , produced voltage and current , heat input and conversion efficiency for various flow rates (), inlet temperatures (C) ) and load resistances () with a constant cold-side temperature ( = 0C) was conducted experimentally. An increase in had a greater effect on the performance than did an increase in . A 3-fold increase in resulted in a 3.2-, 3.1-, 9.7-, 3.5- and 2.8-fold increase in and respectively. For a constant of 50C, a 3-fold increase in from 3300 to 9920 resulted in 1.6-, 1.6-, 2.6-, 1.5- and 1.9-fold increases in , , , and respectively.
Mizuno, Atsushi; Tsugawa, Yusuke; Shimizu, Taro; Nishizaki, Yuji; Okubo, Tomoya; Tanoue, Yusuke; Konishi, Ryota; Shiojiri, Toshiaki; Tokuda, Yasuharu
2016-01-01
Objective Although several studies have been conducted worldwide on factors that might improve residents' knowledge, the relationship between the hospital volume and the internal medicine residents' knowledge has not been fully understood. We conducted a cross-sectional study to compare the relationships of the hospital volume and hospital resources with the residents' knowledge assessed by the In-training Examination. Methods We conducted a retrospective survey and a clinical knowledge evaluation of postgraduate year 1 and 2 (PGY-1 and -2) resident physicians in Japan by using the General Medicine In-training Examination (GM-ITE) in 2014. We compared the ITE score and the hospital volume. Results A total of 2,015 participants (70.6% men; age, 27.3±2.9 years old) from 208 hospitals were retrospectively analyzed. Generalized estimating equations were used, and the results revealed that an increasing number of hospitalizations, decreasing staff number, decreasing age and PGY-2 were significantly associated with higher GM-ITE scores. Conclusion The hospital volume, such as the number of hospitalizations, is thus considered to have a positive impact on the GM-ITE scores.
AHR Activation Is Protective against Colitis Driven by T Cells in Humanized Mice.
Goettel, Jeremy A; Gandhi, Roopali; Kenison, Jessica E; Yeste, Ada; Murugaiyan, Gopal; Sambanthamoorthy, Sharmila; Griffith, Alexandra E; Patel, Bonny; Shouval, Dror S; Weiner, Howard L; Snapper, Scott B; Quintana, Francisco J
2016-10-25
Existing therapies for inflammatory bowel disease that are based on broad suppression of inflammation result in variable clinical benefit and unwanted side effects. A potential therapeutic approach for promoting immune tolerance is the in vivo induction of regulatory T cells (Tregs). Here we report that activation of the aryl hydrocarbon receptor using the non-toxic agonist 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) induces human Tregs in vitro that suppress effector T cells through a mechanism mediated by CD39 and Granzyme B. We then developed a humanized murine system whereby human CD4 + T cells drive colitis upon exposure to 2,4,6-trinitrobenzenesulfonic acid and assessed ITE as a potential therapeutic. ITE administration ameliorated colitis in humanized mice with increased CD39, Granzyme B, and IL10-secreting human Tregs. These results develop an experimental model to investigate human CD4 + T responses in vivo and identify the non-toxic AHR agonist ITE as a potential therapy for promoting immune tolerance in the intestine. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Brandon, A. D.; Debaille, V.; Lapen, T. J.
2010-12-01
The final significant stage of accretion of the Earth was likely a collision between proto-Earth and a Mars sized impactor that formed the Moon. This event is thought to have produced enough thermal energy to melt all or most of the Earth, with a consequent magma ocean (MO). During subsequent cooling, the Earth would have formed its protocrust and corresponding mantle lithosphere, consisting of solidified basalt-komatiitic melt, in combination with buoyant cumulates and late stage residual melts from the MO. Relative to the convecting mantle, portions of this protolithosphere are likely to have been enriched in incompatible trace elements (ITE) in sufficient quantities to contain a significant amount of the bulk Earth’s budget for rare earth elements, U, Th, and Hf. If the protolithosphere was negatively buoyant, it may have overturned at or near the final stages of MO crystallization and a significant portion of that material may have been transported into the deep mantle where it resided and remixed into the convecting mantle over Earth history [1,2]. If the protolithosphere remained positively buoyant, its crust would have likely begun to erode from surface processes, and subsequently recycled back into the mantle over time as sediment and altered crust, once a subduction mechanism arose. The Nd and Hf isotopic compositions of Earth’s earliest rocks support the idea that an early-formed ITE-enriched reservoir was produced. The maxima in 142Nd/144Nd for 3.85 to 3.64 Ga rocks from Isua, Greenland decreases from +20 ppm to +12 ppm relative to the present day mantle value, respectively [3]. This indicates mixing of an early-formed ITE enriched reservoir back into the convecting mantle. In addition, zircons from the 3.1 Ga Jack Hills conglomerate indicate that material with an enriched 176Lu/177Hf of ~0.02 and an age of 4.4 Ga or greater was present at the Earth’s surface over the first 2 Ga of Earth history, supporting the scenario of a positively buoyant, early-formed ITE-enriched reservoir [4]. This early-formed enriched ITE reservoir is indistinguishable in age and 176Lu/177Hf to those that formed in the Moon and Mars [5,6]. Hence all three terrestrial bodies must have undergone similar early differentiation and each formed and sustained their requisite early-formed ITE-enriched reservoirs at or near their surfaces. For all three terrestrial bodies, their early-formed ITE-enriched reservoirs appear to be the result of solidification of late stage residual liquids from their respective MO’s at or prior to 4.4 Ga. In Earth, mixing of an early-formed ITE-enriched reservoir back into the mantle likely occurred back into the convecting mantle at or before 3.9 Ga. For the Moon and Mars, the lack of plate tectonics preserved their early-formed ITE-enriched lithospheric reservoirs. [1] Tolstikhin and Hofmann, PEPI (2005) 148, 109. [2] Boyet and Carlson, Science (2005) 309, 576. [3] Bennett et al., Science (2007) 218, 1907. [3] Kemp et al., EPSL (2010) 296, 45. [5] Taylor et al. (2009) 279, 157. [6] Lapen et al., Science (2010) 328, 347.
16 CFR § 1505.51 - Hot surfaces.
Code of Federal Regulations, 2013 CFR
2013-01-01
... CHILDREN Policies and Interpretations § 1505.51 Hot surfaces. (a) Test probe. Section 1505.6(g)(2) defines... inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the...
ERIC Educational Resources Information Center
Rockel, Jean
2014-01-01
This paper critically examines current concerns regarding professional issues in labour force development for teachers with children up to two years of age (UtoT). The concerns in New Zealand (NZ) relate to whether initial teacher-education (ITE) qualifications prepare teachers to work with children UtoT, involving synergy between ITE and the…
Beginning Teachers Reflect on Inclusive Practices--"I Didn't Realize That He Only Had Half a Hand"
ERIC Educational Resources Information Center
Hamilton, Carol; Kecskemeti, Maria
2015-01-01
Learning to value difference and diversity is a central goal of Initial Teacher Education (ITE) professional practice programmes in New Zealand. Yet the authors have continued to struggle to work with their ITE students to move them as a group towards such valuing in both theory and practice. In this article events that lead up to the changes…
ERIC Educational Resources Information Center
Forsyth, Robert
The readability level of passages from three subtests of the Iowa Tests of Educational Development (ITED), Forms X-6 and Y-6, were compared with the readability level of passages selected from the Des Moines Resister, Reader's Digest, Time, Newsweek, Saturday Review, and 18 high school textbooks from the fields of social studies, science, and…
Zhou, Qian; He, Qizhi; Kang, Jiuhong; Zheng, Jing; Wang, Kai; Duan, Tao
2014-01-01
Vascular remodeling in the placenta is essential for normal fetal development. The previous studies have demonstrated that in utero exposure to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD, an environmental toxicant) induces the intrauterine fetal death in many species via the activation of aryl hydrocarbon receptor (AhR). In the current study, we compared the effects of 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) and TCDD on the vascular remodeling of rat placentas. Pregnant rats on gestational day (GD) 15 were randomly assigned into 5 groups, and were exposed to a single dose of 1.6 and 8.0 mg/kg body weight (bw) ITE, 1.6 and 8.0 µg/kg bw TCDD, or an equivalent volume of the vehicle, respectively. The dams were sacrificed on GD20 and the placental tissues were gathered. The intrauterine fetal death was observed only in 8.0 µg/kg bw TCDD-exposed group and no significant difference was seen in either the placental weight or the fetal weight among all these groups. The immunohistochemical and histological analyses revealed that as compared with the vehicle-control, TCDD, but not ITE, suppressed the placental vascular remodeling, including reduced the ratio of the placental labyrinth zone to the basal zone thickness (at least 0.71 fold of control), inhibited the maternal sinusoids dilation and thickened the trophoblastic septa. However, no marked difference was observed in the density of fetal capillaries in the labyrinth zone among these groups, although significant differences were detected in the expression of angiogenic growth factors between ITE and TCDD-exposed groups, especially Angiopoietin-2 (Ang-2), Endoglin, Interferon-γ (IFN-γ) and placenta growth factor (PIGF). These results suggest ITE and TCDD differentially regulate the vascular remodeling of rat placentas, as well as the expression of angiogenic factors and their receptors, which in turn may alter the blood flow in the late gestation and partially resulted in intrauterine fetal death. PMID:24475139
Undirected learning styles and academic risk: Analysis of the impact of stress, strain and coping.
Kimatian, Stephen; Lloyd, Sara; Berger, Jeffrey; Steiner, Lorraine; McKay, Robert; Schwengal, Deborah
2017-01-01
Learning style inventories used in conjunction with a measure of academic achievement consistently show an association of meaning directed learning patterns with academic success, but have failed to show a clear association of undirected learning styles with academic failure. Using survey methods with anesthesia residents, this study questioned whether additional assessment of factors related to stress, strain, and coping help to better define the association between undirected learning styles and academic risk. Pearson chi squared tests. 296 subjects were enrolled from eight institutions with 142 (48%) completing the study. American Board of Anesthesiologists In Training Examinations (ITE) percentiles (ITE%) were used as a measure of academic achievement. The Vermunt Inventory of Learning Styles (ILS) was used to identify four learning patterns and 20 strategies, and the Osipow Stress Inventory-Revised (OSI-R) was used as a measure of six scales of occupational stress, four of personal strain, and four coping resources. Two learning patterns had significant relationship with ITE scores. As seen in previous studies, Meaning Directed Learning was beneficial for academic achievement while Undirected Learning was the least beneficial. Higher scores on Meaning Directed Learning correlated positively with higher ITE scores while higher Undirected and lower Meaning Directed patterns related negatively to ITE%. OSI-R measures of stress, strain and coping indicated that residents with Undirected learning patterns had higher scores on three scales related to stress, and 4 related to strain, while displaying lower scores on two scales related to coping. Residents with higher Meaning Directed patterns scored lower on two scales of stress and two scales of strain, with higher scores on two scales for coping resources. Low Meaning Directed and high Undirected learning patterns correlated with lower ITE percentiles, higher scores for stress and strain, and lower coping resources. This association suggests that successful remediation of at-risk residents must address stress, strain and coping if long term academic improvement is expected. Further research to identify the value of stress, strain, and coping screening and education is warranted.
Drake, Sean M; Qureshi, Waqas; Morse, William; Baker-Genaw, Kimberly
2015-01-01
The American Board of Internal Medicine (ABIM) exam's pass rate is considered a quality measure of a residency program, yet few interventions have shown benefit in reducing the failure rate. We developed a web-based Directed Reading (DR) program with an aim to increase medical knowledge and reduce ABIM exam failure rate. Internal medicine residents at our academic medical center with In-Training Examination (ITE) scores ≤ 35 th percentile from 2007 to 2013 were enrolled in DR. The program matches residents to reading assignments based on their own ITE-failed educational objectives and provides direct electronic feedback from their teaching physicians. ABIM exam pass rates were analyzed across various groups between 2002 and 2013 to examine the effect of the DR program on residents with ITE scores ≤ 35 percentile pre- (2002-2006) and post-intervention (2007-2013). A time commitment survey was also given to physicians and DR residents at the end of the study. Residents who never scored ≤ 35 percentile on ITE were the most likely to pass the ABIM exam on first attempt regardless of time period. For those who ever scored ≤ 35 percentile on ITE, 91.9% of residents who participated in DR passed the ABIM exam on first attempt vs 85.2% of their counterparts pre-intervention (p < 0.001). This showed an improvement in ABIM exam pass rate for this subset of residents after introduction of the DR program. The time survey showed that faculty used an average of 40±18 min per week to participate in DR and residents required an average of 25 min to search/read about the objective and 20 min to write a response. Although residents who ever scored ≤ 35 percentile on ITE were more likely to fail ABIM exam on first attempt, those who participated in the DR program were less likely to fail than the historical control counterparts. The web-based teaching method required little time commitment by faculty.
Drake, Sean M.; Qureshi, Waqas; Morse, William; Baker-Genaw, Kimberly
2015-01-01
Aim The American Board of Internal Medicine (ABIM) exam's pass rate is considered a quality measure of a residency program, yet few interventions have shown benefit in reducing the failure rate. We developed a web-based Directed Reading (DR) program with an aim to increase medical knowledge and reduce ABIM exam failure rate. Methods Internal medicine residents at our academic medical center with In-Training Examination (ITE) scores ≤35th percentile from 2007 to 2013 were enrolled in DR. The program matches residents to reading assignments based on their own ITE-failed educational objectives and provides direct electronic feedback from their teaching physicians. ABIM exam pass rates were analyzed across various groups between 2002 and 2013 to examine the effect of the DR program on residents with ITE scores ≤35 percentile pre- (2002–2006) and post-intervention (2007–2013). A time commitment survey was also given to physicians and DR residents at the end of the study. Results Residents who never scored ≤35 percentile on ITE were the most likely to pass the ABIM exam on first attempt regardless of time period. For those who ever scored ≤35 percentile on ITE, 91.9% of residents who participated in DR passed the ABIM exam on first attempt vs 85.2% of their counterparts pre-intervention (p<0.001). This showed an improvement in ABIM exam pass rate for this subset of residents after introduction of the DR program. The time survey showed that faculty used an average of 40±18 min per week to participate in DR and residents required an average of 25 min to search/read about the objective and 20 min to write a response. Conclusions Although residents who ever scored ≤35 percentile on ITE were more likely to fail ABIM exam on first attempt, those who participated in the DR program were less likely to fail than the historical control counterparts. The web-based teaching method required little time commitment by faculty. PMID:26521767
Awareness of Diagnostic Error among Japanese Residents: a Nationwide Study.
Nishizaki, Yuji; Shinozaki, Tomohiro; Kinoshita, Kensuke; Shimizu, Taro; Tokuda, Yasuharu
2018-04-01
Residents' understanding of diagnostic error may differ between countries. We sought to explore the relationship between diagnostic error knowledge and self-study, clinical knowledge, and experience. Our nationwide study involved postgraduate year 1 and 2 (PGY-1 and -2) Japanese residents. The Diagnostic Error Knowledge Assessment Test (D-KAT) and General Medicine In-Training Examination (GM-ITE) were administered at the end of the 2014 academic year. D-KAT scores were compared with the benchmark scores of US residents. Associations between D-KAT score and gender, PGY, emergency department (ED) rotations per month, mean number of inpatients handled at any given time, and mean daily minutes of self-study were also analyzed, both with and without adjusting for GM-ITE scores. Student's t test was used for comparisons with linear mixed models and structural equation models (SEM) to explore associations with D-KAT or GM-ITE scores. The mean D-KAT score among Japanese PGY-2 residents was significantly lower than that of their US PGY-2 counterparts (6.2 vs. 8.3, p < 0.001). GM-ITE scores correlated with ED rotations (≥6 rotations: 2.14; 0.16-4.13; p = 0.03), inpatient caseloads (5-9 patients: 1.79; 0.82-2.76; p < 0.001), and average daily minutes of self-study (≥91 min: 2.05; 0.56-3.53; p = 0.01). SEM revealed that D-KAT scores were directly associated with GM-ITE scores (ß = 0.37, 95% CI: 0.34-0.41) and indirectly associated with ED rotations (ß = 0.06, 95% CI: 0.02-0.10), inpatient caseload (ß = 0.04, 95% CI: 0.003-0.08), and average daily minutes of study (ß = 0.13, 95% CI: 0.09-0.17). Knowledge regarding diagnostic error among Japanese residents was poor compared with that among US residents. D-KAT scores correlated strongly with GM-ITE scores, and the latter scores were positively associated with a greater number of ED rotations, larger caseload (though only up to 15 patients), and more time spent studying.
Drake, Sean M; Qureshi, Waqas; Morse, William; Baker-Genaw, Kimberly
2015-01-01
Aim The American Board of Internal Medicine (ABIM) exam's pass rate is considered a quality measure of a residency program, yet few interventions have shown benefit in reducing the failure rate. We developed a web-based Directed Reading (DR) program with an aim to increase medical knowledge and reduce ABIM exam failure rate. Methods Internal medicine residents at our academic medical center with In-Training Examination (ITE) scores ≤35th percentile from 2007 to 2013 were enrolled in DR. The program matches residents to reading assignments based on their own ITE-failed educational objectives and provides direct electronic feedback from their teaching physicians. ABIM exam pass rates were analyzed across various groups between 2002 and 2013 to examine the effect of the DR program on residents with ITE scores ≤35 percentile pre- (2002-2006) and post-intervention (2007-2013). A time commitment survey was also given to physicians and DR residents at the end of the study. Results Residents who never scored ≤35 percentile on ITE were the most likely to pass the ABIM exam on first attempt regardless of time period. For those who ever scored ≤35 percentile on ITE, 91.9% of residents who participated in DR passed the ABIM exam on first attempt vs 85.2% of their counterparts pre-intervention (p<0.001). This showed an improvement in ABIM exam pass rate for this subset of residents after introduction of the DR program. The time survey showed that faculty used an average of 40±18 min per week to participate in DR and residents required an average of 25 min to search/read about the objective and 20 min to write a response. Conclusions Although residents who ever scored ≤35 percentile on ITE were more likely to fail ABIM exam on first attempt, those who participated in the DR program were less likely to fail than the historical control counterparts. The web-based teaching method required little time commitment by faculty.
Deep Space Network Capabilities for Receiving Weak Probe Signals
NASA Technical Reports Server (NTRS)
Asmar, Sami; Johnston, Doug; Preston, Robert
2005-01-01
Planetary probes can encounter mission scenarios where communication is not favorable during critical maneuvers or emergencies. Launch, initial acquisition, landing, trajectory corrections, safing. Communication challenges due to sub-optimum antenna pointing or transmitted power, amplitude/frequency dynamics, etc. Prevent lock-up on signal and extraction of telemetry. Examples: loss of Mars Observer, nutation of Ulysses, Galileo antenna, Mars Pathfinder and Mars Exploration Rovers Entry, Descent, and Landing, and the Cassini Saturn Orbit Insertion. A Deep Space Network capability to handle such cases has been used successfully to receive signals to characterize the scenario. This paper will describe the capability and highlight the cases of the critical communications for the Mars rovers and Saturn Orbit Insertion and preparation radio tracking of the Huygens probe at (non-DSN) radio telescopes.
Redetermination of clinobarylite, BaBe2Si2O7
Domizio, Adrien J. Di; Downs, Robert T.; Yang, Hexiong
2012-01-01
Clinobarylite, ideally BaBe2Si2O7 (chemical name barium diberyllium disilicate), is a sorosilicate mineral and dimorphic with barylite. It belongs to a group of compounds characterized by the general formula BaM 2+ 2Si2O7, with M 2+ = Be, Mg, Fe, Mn, Zn, Co, or Cu, among which the Be-, Fe-, and Cu-members have been found in nature. The crystal structure of clinobarylite has been re-examined in this study based on single-crystal X-ray diffraction data collected from a natural sample from the type locality (Khibiny Massif, Kola Peninsula, Russia). The structure of clinobarylite can be considered as a framework of BeO4 and SiO4 tetrahedra, with one of the O atoms coordinated to two Be and one Si, one coordinated to two Si, and two O atoms coordinated to one Si and one Be atom. The BeO4 tetrahedra share corners, forming chains parallel to the c axis, which are interlinked by the Si2O7 units oriented parallel to the a axis. The Ba2+ cations (site symmetry m..) are in the framework channels and are coordinated by eleven O atoms in form of an irregular polyhedron. The Si—Obr (bridging O atom, at site symmetry m..) bond length, the Si—Onbr (non-bridging O atoms) bond lengths, and the Si—O—Si angle within the Si2O7 unit are in marked contrast to the corresponding values determined in the previous study [Krivovichev et al. (2004 ▶). N. Jb. Miner. Mh. pp. 373–384]. PMID:23125568
A tryptophan derivative, ITE, enhances liver cell metabolic functions in vitro
Zhang, Xiaoqian; Lu, Juan; He, Bin; Tang, Lingling; Liu, Xiaoli; Zhu, Danhua; Cao, Hongcui; Wang, Yingjie; Li, Lanjuan
2017-01-01
Cell encapsulation provides a three-dimensional support by incorporating isolated cells into microcapsules with the goal of simultaneously maintaining cell survival and function, as well as providing active transport for a bioreactor in vitro similarly to that observed in vivo. However, the biotransformation and metabolic functions of the encapsulated cells are not satisfactory for clinical applications. For this purpose, in this study, hepatoma-derived Huh7 cells/C3A cells were treated with 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), an endogenous non-toxic ligand for aryl hydrocarbon receptor, in monolayer cultures and on microspheres. The mRNA and protein levels, as well as the metabolic activities of drug metabolizing enzymes, albumin secretion and urea synthesis were determined. When the Huh7 and C3A cells cultured in a monolayer on two-dimensional surfaces, ITE enhanced the protein levels and the metabolic activities of the major cytochrome P450 (CYP450) enzymes, CYP1A1, CYP1A2, CYP3A4 and CYP1B1, and slightly increased albumin secretion and urea synthesis. Moreover, when cultured on microspheres, ITE also substantially increased the protein levels and metabolic activities of CYP1A1, CYP1A2, CYP3A4 and CYP1B1 in both liver cell lines. On the whole, our findings indicate that ITE enhances the enzymatic activities of major CYP450 enzymes and the metabolic functions of liver cells cultured in monolayer or on microspheres, indicating that it may be utilized to improve the functions of hepatocytes. Thus, it may be used in the future for the treatment of liver diseases. PMID:27959388
A tryptophan derivative, ITE, enhances liver cell metabolic functions in vitro.
Zhang, Xiaoqian; Lu, Juan; He, Bin; Tang, Lingling; Liu, Xiaoli; Zhu, Danhua; Cao, Hongcui; Wang, Yingjie; Li, Lanjuan
2017-01-01
Cell encapsulation provides a three-dimensional support by incorporating isolated cells into microcapsules with the goal of simultaneously maintaining cell survival and function, as well as providing active transport for a bioreactor in vitro similarly to that observed in vivo. However, the biotra-nsformation and metabolic functions of the encapsulated cells are not satisfactory for clinical applications. For this purpose, in this study, hepatoma-derived Huh7 cells/C3A cells were treated with 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE), an endogenous non-toxic ligand for aryl hydrocarbon receptor, in monolayer cultures and on microspheres. The mRNA and protein levels, as well as the metabolic activities of drug metabolizing enzymes, albumin secretion and urea synthesis were determined. When the Huh7 and C3A cells cultured in a monolayer on two‑dimensional surfaces, ITE enhanced the protein levels and the metabolic activities of the major cytochrome P450 (CYP450) enzymes, CYP1A1, CYP1A2, CYP3A4 and CYP1B1, and slightly increased albumin secretion and urea synthesis. Moreover, when cultured on microspheres, ITE also substantially increased the protein levels and metabolic activities of CYP1A1, CYP1A2, CYP3A4 and CYP1B1 in both liver cell lines. On the whole, our findings indicate that ITE enhances the enzymatic activities of major CYP450 enzymes and the metabolic functions of liver cells cultured in monolayer or on microspheres, indicating that it may be utilized to improve the functions of hepatocytes. Thus, it may be used in the future for the treatment of liver diseases.
Redetermination of clinobaryl-ite, BaBe(2)Si(2)O(7).
Domizio, Adrien J Di; Downs, Robert T; Yang, Hexiong
2012-10-01
Clinobaryl-ite, ideally BaBe(2)Si(2)O(7) (chemical name barium diberyllium disilicate), is a sorosilicate mineral and dimorphic with baryl-ite. It belongs to a group of compounds characterized by the general formula BaM(2+) (2)Si(2)O(7), with M(2+) = Be, Mg, Fe, Mn, Zn, Co, or Cu, among which the Be-, Fe-, and Cu-members have been found in nature. The crystal structure of clinobaryl-ite has been re-examined in this study based on single-crystal X-ray diffraction data collected from a natural sample from the type locality (Khibiny Massif, Kola Peninsula, Russia). The structure of clinobaryl-ite can be considered as a framework of BeO(4) and SiO(4) tetra-hedra, with one of the O atoms coordinated to two Be and one Si, one coordinated to two Si, and two O atoms coordinated to one Si and one Be atom. The BeO(4) tetra-hedra share corners, forming chains parallel to the c axis, which are inter-linked by the Si(2)O(7) units oriented parallel to the a axis. The Ba(2+) cations (site symmetry m..) are in the framework channels and are coordinated by eleven O atoms in form of an irregular polyhedron. The Si-O(br) (bridging O atom, at site symmetry m..) bond length, the Si-O(nbr) (non-bridging O atoms) bond lengths, and the Si-O-Si angle within the Si(2)O(7) unit are in marked contrast to the corresponding values determined in the previous study [Krivovichev et al. (2004 ▶). N. Jb. Miner. Mh. pp. 373-384].
Factors Associated with Medical Knowledge Acquisition During Internal Medicine Residency
Zeger, Scott L.; Kolars, Joseph C.
2007-01-01
BACKGROUND Knowledge acquisition is a goal of residency and is measurable by in-training exams. Little is known about factors associated with medical knowledge acquisition. OBJECTIVE To examine associations of learning habits on medical knowledge acquisition. DESIGN, PARTICIPANTS Cohort study of all 195 residents who took the Internal Medicine In-Training Examination (IM-ITE) 421 times over 4 years while enrolled in the Internal Medicine Residency, Mayo Clinic, Rochester, MN. MEASUREMENTS Score (percent questions correct) on the IM-ITE adjusted for variables known or hypothesized to be associated with score using a random effects model. RESULTS When adjusting for demographic, training, and prior achievement variables, yearly advancement within residency was associated with an IM-ITE score increase of 5.1% per year (95%CI 4.1%, 6.2%; p < .001). In the year before examination, comparable increases in IM-ITE score were associated with attendance at two curricular conferences per week, score increase of 3.9% (95%CI 2.1%, 5.7%; p < .001), or self-directed reading of an electronic knowledge resource 20 minutes each day, score increase of 4.5% (95%CI 1.2%, 7.8%; p = .008). Other factors significantly associated with IM-ITE performance included: age at start of residency, score decrease per year of increasing age, −0.2% (95%CI −0.36%, −0.042%; p = .01), and graduation from a US medical school, score decrease compared to international medical school graduation, −3.4% (95%CI −6.5%, −0.36%; p = .03). CONCLUSIONS Conference attendance and self-directed reading of an electronic knowledge resource had statistically and educationally significant independent associations with knowledge acquisition that were comparable to the benefit of a year in residency training. PMID:17468889
Wang, C; Ye, Z; Kijlstra, A; Zhou, Y; Yang, P
2014-08-01
Aryl hydrocarbon receptor (AhR) is well known for mediating the toxic effects of dioxin-containing pollutants, but has also been shown to be involved in the natural regulation of the immune response. In this study, we investigated the effect of AhR activation by its endogenous ligands 6-formylindolo[3,2-b]carbazole (FICZ) and 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) on the differentiation, maturation and function of monocyte-derived DCs in Behçet's disease (BD) patients. In this study, we showed that AhR activation by FICZ and ITE down-regulated the expression of co-stimulatory molecules including human leucocyte antigen D-related (HLA-DR), CD80 and CD86, while it had no effect on the expression of CD83 and CD40 on DCs derived from BD patients and normal controls. Lipopolysaccharide (LPS)-treated dendritic cells (DCs) from active BD patients showed a higher level of interleukin (IL)-1β, IL-6, IL-23 and tumour necrosis factor (TNF)-α production. FICZ or ITE significantly inhibited the production of IL-1β, IL-6, IL-23 and TNF-α, but induced IL-10 production by DCs derived from active BD patients and normal controls. FICZ or ITE-treated DCs significantly inhibited the T helper type 17 (Th17) and Th1 cell response. Activation of AhR either by FICZ or ITE inhibits DC differentiation, maturation and function. Further studies are needed to investigate whether manipulation of the AhR pathway may be used to treat BD or other autoimmune diseases. © 2014 British Society for Immunology.
Wang, C; Ye, Z; Kijlstra, A; Zhou, Y; Yang, P
2014-01-01
Aryl hydrocarbon receptor (AhR) is well known for mediating the toxic effects of dioxin-containing pollutants, but has also been shown to be involved in the natural regulation of the immune response. In this study, we investigated the effect of AhR activation by its endogenous ligands 6-formylindolo[3,2-b]carbazole (FICZ) and 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) on the differentiation, maturation and function of monocyte-derived DCs in Behçet's disease (BD) patients. In this study, we showed that AhR activation by FICZ and ITE down-regulated the expression of co-stimulatory molecules including human leucocyte antigen D-related (HLA-DR), CD80 and CD86, while it had no effect on the expression of CD83 and CD40 on DCs derived from BD patients and normal controls. Lipopolysaccharide (LPS)-treated dendritic cells (DCs) from active BD patients showed a higher level of interleukin (IL)-1β, IL-6, IL-23 and tumour necrosis factor (TNF)-α production. FICZ or ITE significantly inhibited the production of IL-1β, IL-6, IL-23 and TNF-α, but induced IL-10 production by DCs derived from active BD patients and normal controls. FICZ or ITE-treated DCs significantly inhibited the T helper type 17 (Th17) and Th1 cell response. Activation of AhR either by FICZ or ITE inhibits DC differentiation, maturation and function. Further studies are needed to investigate whether manipulation of the AhR pathway may be used to treat BD or other autoimmune diseases. PMID:24749687
NASA Astrophysics Data System (ADS)
Morales, Carmen E.; Anabalón, Valeria; Bento, Joaquim P.; Hormazabal, Samuel; Cornejo, Marcela; Correa-Ramírez, Marco A.; Silva, Nelson
2017-11-01
In eastern boundary current systems (EBCSs), submesoscale to mesocale variability contributes to cross-shore exchanges of water properties, nutrients, and plankton. Data from a short-term summer survey and satellite time series (January-February 2014) were used to characterize submesoscale variability in oceanographic conditions and phytoplankton distribution across the coastal upwelling and coastal transition zones north of Punta Lavapié, and to explore cross-shelf exchanges of diatom taxa. A thermohaline front (FRN-1) flanked by a mesoscale anticyclonic intrathermocline eddy (ITE-1), or mode-water eddy, persisted during the time series and the survey was undertaken during a wind relaxation event. At the survey time, ITE-1 contributed to an onshore intrusion of warm oceanic waters (southern section) and an offshore advection of cold coastal waters (northern section), with the latter forming a cold, high chlorophyll-a filament. In situ phytoplankton and diatom biomasses were highest at the surface in FRN-1 and at the subsurface in ITE-1, whereas values in the coastal zone were lower and dominated by smaller cells. Diatom species typical of the coastal zone and species dominant in oceanic waters were both found in the FRN-1 and ITE-1 interaction area, suggesting that this mixture was the result of both offshore and onshore advection. Overall, front-eddy interactions in EBCSs could enhance cross-shelf exchanges of coastal and oceanic plankton, as well as sustain phytoplankton growth in the slope area through localized upward injections of nutrients in the frontal zone, combined with ITE-induced advection and vertical nutrient inputs to the surface layer.
Gene Hern, H; Wills, Charlotte; Alter, Harrison; Bowman, Steven H; Katz, Eric; Shayne, Philip; Vahidnia, Farnaz
2009-12-01
The residency review committee for emergency medicine (EM) requires residents to have greater than 70% attendance of educational conferences during residency training, but it is unknown whether attendance improves clinical competence or scores on the American Board of Emergency Medicine (ABEM) in-training examination (ITE). This study examined the relationship between conference attendance and ITE scores. The hypothesis was that greater attendance would correlate to a higher examination score. This was a multi-center retrospective cohort study using conference attendance data and examination results from residents in four large county EM residency training programs. Longitudinal multi-level models, adjusting for training site, U.S. Medical Licensing Examination (USMLE) Step 1 score, and sex were used to explore the relationship between conference attendance and in-training examination scores according to year of training. Each year of training was studied, as well as the overall effect of mean attendance as it related to examination score. Four training sites reported data on 405 residents during 2002 to 2008; 386 residents had sufficient data to analyze. In the multi-level longitudinal models, attendance at conference was not a significant predictor of in-training percentile score (coefficient = 0.005, 95% confidence interval [CI] = -0.053 to 0.063, p = 0.87). Score on the USMLE Step 1 examination was a strong predictor of ITE score (coefficient = 0.186, 95% CI = 0.155 to 0.217; p < 0.001), as was female sex (coefficient = 2.117, 95% CI = 0.987 to 3.25; p < 0.001). Greater conference attendance does not correlate with performance on an individual's ITE scores. Conference attendance may represent an important part of EM residency training but perhaps not of ITE performance. (c) 2009 by the Society for Academic Emergency Medicine.
Impact of Moodle-Based Online Curriculum on Thoracic Surgery In-Training Examination Scores.
Antonoff, Mara B; Verrier, Edward D; Allen, Mark S; Aloia, Lauren; Baker, Craig; Fann, James I; Iannettoni, Mark D; Yang, Stephen C; Vaporciyan, Ara A
2016-10-01
The feasibility and efficacy of a web-based curriculum in supplementing thoracic surgical training was previously shown. However, the impact of curricular participation on validated knowledge tests remains unknown. We compared in-service training examination (ITE) results among trainees, stratified by curricular use. The national online curriculum was implemented in August 2013. We retrospectively reviewed trainees who participated in thoracic surgical training programs in both 2012 to 2013 and 2013 to 2014. Scores from the 2013 and 2014 ITEs were obtained, and curricular usage data were collected from site analytics. Trainees were separated into three groups according to 2013 ITE scores; within each group, changes in score for high- versus low-volume users were compared. 187 trainees took the ITE both years, with exposure to the online curriculum during only the second year. High-volume users' scores trended toward greater improvement than scores of low-volume users (+18.2% versus +13.0%, p = 0.199). When stratified by 2013 score, the lowest scoring quartile improved substantially, and the highest scoring quartile improved modestly, regardless of curricular use. However, for those individuals who achieved mid-range scores in 2013, there was a trend toward much greater improvement in score with heavier use of the curriculum (+17.0% versus +7.0%, p = 0.094). Among trainees who had access to the novel online curriculum during the second of 2 consecutive years, we evaluated the impact of curricular participation on ITE scores. The effect appears to be most pronounced in individuals with mid-range scores, in whom high curricular use led to the greatest improvement. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gravenor, C. P.; von Brunn, V.; Dreimanis, A.
1984-03-01
This study of waterlain glaciogenic sediments is designed to present both a review and new information on glaciogenic subaquatic deposits of differing age in a number of localities in North and South America and South Africa. The Late Paleozoic glaciogenic deposits of the ParanáBasin in Brazil and the Karoo Basin of South Africa are singled out for special attention as they show a reasonably complete lateral sequence of terrestrial to off-shore glaciogenic sedimentation. Although the environment of subaquatic glaciogenic sedimentation varies from one area to the next, certain common elements are found which can be used to develop a generalized model for both glaciomarine and glaciolacustrine sedimentation. For descriptive purposes, the model is divided into two broad categories: a shelf facies and a basinal facies. The shelf facies is marked by massive diamicton(ite) which may be 200 m or more in thickness and which is frequently overlain by a complex of clastic sediments consisting primarily of gravity and fluid flows. The basinal facies is marked by products of subaquatic slumps and more distal turbidites and glaciomarine sediments. New terminology is introduced. The massive diamicton(ite), which is diagnostic of the shelf facies, probably represents deposition from the base of active ice in a subaquatic environment and is termed undermelt diamicton(ite). The gravity and fluid flows which are usually found overlying undermelt diamicton(ite) and in the basinal facies are subdivided into six categories: glaciogenic subaquatic outwash, glaciogenic suspension flow, glaciogenic chaotic debris flow, glaciogenic subaquatic debris flow, glaciogenic slurry flow and glaciogenic turbidity flow. The relative abundance of undermelt diamicton(ite) and the various types of gravity and fluid flows can be used to define inner shelf, outer shelf, inner basin and outer basin facies of glaciomarine sedimentation.
ERIC Educational Resources Information Center
Hamodi, Carolina; López-Pastor, Víctor Manuel; López-Pastor, Ana Teresa
2017-01-01
The aim of this article is to analyse whether having experience of formative assessment during their initial teacher education courses (ITE) influences graduates' subsequent practice as teachers. That is, if the assessment methods that university students are subject to during their learning process are then actually employed by them during their…
Decreased expression of the aryl hydrocarbon receptor in ocular Behcet's disease.
Wang, Chaokui; Ye, Zi; Kijlstra, Aize; Zhou, Yan; Yang, Peizeng
2014-01-01
Recent studies show that the aryl hydrocarbon receptor (AhR) is involved in immune responses. AhR is activated following interaction with its ligands, such as 6-formylindolo[3,2-b]carbazole (FICZ) and 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). In this study, we investigated the role of AhR activation by its endogenous ligands in the pathogenesis of ocular Behcet's disease (BD). The expression of AhR was significantly decreased in active BD patients as compared to inactive BD patients and normal controls. Both FICZ and ITE inhibited Th1 and Th17 polarization and induced the expression of IL-22 by PBMCs and by CD4(+)T cells in active BD patients and normal controls. Stimulation of purified CD4(+)T cells with FICZ or ITE caused a decreased expression of RORC, IL-17, IL-23R, and CCR6 and an increased phosphorylation of STAT3 and STAT5. The present study suggests that a decreased AhR expression is associated with disease activity in BD patients. The activation of AhR by either FICZ or ITE was able to inhibit Th1 and Th17 cell polarization. Further studies are needed to investigate whether modulation of AhR might be used in the treatment of BD.
Kravchick, Sergey; Peled, Ronit; Ben-Dor, David; Dorfman, Dov; Kesari, David; Cytron, Shmuel
2005-01-01
To introduce two forms of anesthesia and compare them with standard local anesthesia techniques. A total of 114 consecutive patients underwent prostate needle biopsy. The patients were sequentially randomized to receive different kinds of anesthesia: 2% rectal lidocaine gel, 40% dimethyl sulfoxide (DMSO) with lidocaine, perianal injection of 1% lidocaine, or periprostatic nerve block. Pain perception was separately assessed for probe insertion and biopsies using a visual pain analog score. One-way analysis of variance was used to compare the data scale among the four groups. A linear regression model was used to define the independent variables that predicted the level of pain. The groups were similar in terms of age, prostate-specific antigen levels, digital rectal examination findings, prostate volume, pain tolerance, biopsy time, and number of cores taken. The lowest pain scores for probe insertion were for the perianal injection and DMSO/lidocaine groups (0.89 and 1.38, respectively). The difference between these scores and those for the other two groups was statistically significant (P <0.001). Pain perception during biopsy did not differ significantly among the DMSO/lidocaine, perianal, or periprostatic groups and was greatest in the lidocaine gel group (4.147; P <0.001). We did not observe any statistically significant correlation between the pain level during probe insertion and biopsy and pain tolerance (P = 0.514 and P = 0.788, respectively). The anesthesia type was the strongest single predictor of the pain level during biopsy (P <0.001). The use of 40% DMSO with lidocaine instilled into the rectal vault for 10 minutes avoids any need for injection and is capable of decreasing the discomfort or pain experienced during probe insertion and prostate biopsy comparable to the perianal and periprostatic protocols.
Use of radioactive sources in measuring characteristics of snowpacks
Henry W. Anderson; Philip M. McDonald; Lloyd W. Gay
1963-01-01
Use of radioactive probes inserted in mountain snowpacks may make possible more accurate appraisal and prediction of snowmelt water. Commercially available gamma and neutron probes were tested for their ability to measure snow density, ice lenses, and the thermal quality of individual layers in the snowpack.
Limberger, Jones; Leal, Bárbara C.; Monteiro, Adriano L.
2015-01-01
In recent years, charge-tagged ligands (CTLs) have become valuable tools in organometallic catalysis. Insertion of an ionic side chain into the molecular skeleton of a known ligand has become a useful protocol for anchoring ligands, and consequently catalysts, in polar and ionic liquid phases. In addition, the insertion of a cationic moiety into a ligand is a powerful tool that can be used to detect reaction intermediates in organometallic catalysis through electrospray ionisation mass spectrometry (ESI-MS) experiments. The insertion of an ionic tag ensures the charge in the intermediates independently of the ESI-MS. For this reason, these ligands have been used as ionic probes in mechanistic studies for several catalytic reactions. Here, we summarise selected examples on the use of CTLs as immobilising agents in organometallic catalysis and as probes for studying mechanisms through ESI-MS. PMID:28553458
ERIC Educational Resources Information Center
European Commission, 2017
2017-01-01
Research in initial teacher education (ITE) usually focuses on the policies and practices that shape the professional preparation of candidate teachers. There is a wide range of such policies and practices in Europe. One of the main reasons for such heterogeneity is that there is no agreement on what ITE curricula should particularly emphasise…
ERIC Educational Resources Information Center
Knight, Rupert
2012-01-01
The role of theory in educational practice has long been seen as problematic (Pring 2004) and within initial teacher education (ITE) specifically, various models linking the two have been proposed (Korthagen 2010). In England, ITE is currently in a state of flux, with the majority of university-based postgraduate programmes operating partly at…
NASA Astrophysics Data System (ADS)
Campos-García, Manuel; Granados-Agustín, Fermín.; Cornejo-Rodríguez, Alejandro; Estrada-Molina, Amilcar; Avendaño-Alejo, Maximino; Moreno-Oliva, Víctor Iván.
2013-11-01
In order to obtain a clearer interpretation of the Intensity Transport Equation (ITE), in this work, we propose an algorithm to solve it for some particular wavefronts and its corresponding intensity distributions. By simulating intensity distributions in some planes, the ITE is turns into a Poisson equation with Neumann boundary conditions. The Poisson equation is solved by means of the iterative algorithm SOR (Simultaneous Over-Relaxation).
NASA Astrophysics Data System (ADS)
Hara, Seth A.; Kim, Brian J.; Kuo, Jonathan T. W.; Lee, Curtis D.; Meng, Ellis; Pikov, Victor
2016-12-01
Objective. Acquisition of reliable and robust neural recordings with intracortical neural probes is a persistent challenge in the field of neuroprosthetics. We developed a multielectrode array technology to address chronic intracortical recording reliability and present in vivo recording results. Approach. The 2 × 2 Parylene sheath electrode array (PSEA) was microfabricated and constructed from only Parylene C and platinum. The probe includes a novel three-dimensional sheath structure, perforations, and bioactive coatings that improve tissue integration and manage immune response. Coatings were applied using a sequential dip-coating method that provided coverage over the entire probe surface and interior of the sheath structure. A sharp probe tip taper facilitated insertion with minimal trauma. Fabricated probes were subject to examination by optical and electron microscopy and electrochemical testing prior to implantation. Main results. 1 × 2 arrays were successfully fabricated on wafer and then packaged together to produce 2 × 2 arrays. Then, probes having electrode sites with adequate electrochemical properties were selected. A subset of arrays was treated with bioactive coatings to encourage neuronal growth and suppress inflammation and another subset of arrays was implanted in conjunction with a virally mediated expression of Caveolin-1. Arrays were attached to a custom-made insertion shuttle to facilitate precise insertion into the rat motor cortex. Stable electrophysiological recordings were obtained during the period of implantation up to 12 months. Immunohistochemical evaluation of cortical tissue around individual probes indicated a strong correlation between the electrophysiological performance of the probes and histologically observable proximity of neurons and dendritic sprouting. Significance. The PSEA demonstrates the scalability of sheath electrode technology and provides higher electrode count and density to access a greater volume for recording. This study provided support for the importance of creating a supportive biological environment around the probes to promote the long-term electrophysiological performance of flexible probes in the cerebral cortex. In particular, we demonstrated beneficial effects of the Matrigel coating and the long-term expression of Caveolin-1. Furthermore, we provided support to an idea of using an artificial acellular tissue compartment as a way to counteract the walling-off effect of the astrocytic scar formation around the probes as a means of establishing a more intimate and stable neural interface.
Impurity trapped excitons under high hydrostatic pressure
NASA Astrophysics Data System (ADS)
Grinberg, Marek
2013-09-01
Paper summarizes the results on pressure effect on energies of the 4fn → 4fn and 4fn-15d1 → 4fn transitions as well as influence of pressure on anomalous luminescence in Lnα+ doped oxides and fluorides. A model of impurity trapped exciton (ITE) was developed. Two types of ITE were considered. The first where a hole is localized at the Lnα+ ion (creation of Ln(α+1)+) and an electron is attracted by Coulomb potential at Rydberg-like states and the second where an electron captured at the Lnα+ ion (creation of Ln(α-1)+) and a hole is attracted by Coulomb potential at Rydberg-like states. Paper presents detailed analysis of nonlinear changes of energy of anomalous luminescence of BaxSr1-xF2:Eu2+ (x > 0.3) and LiBaF3:Eu2+, and relate them to ITE-4f65d1 states mixing.
Effect of leg exercise training on vascular volumes during 30 days of 6 deg head-down bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Vernikos, J.; Wade, C. E.; Barnes, P. R.
1992-01-01
In order to investigate the effects of leg exercise training on vascular volumes during 30 d of 6-deg head-down bed rest, plasma and red cell volumes, body density, and water balance were measured in 19 men confined to bed rest (BR). One group had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise (ITE) for 60 min/d, and the third near-maximal intermittent isokinetic exercise (IKE) for 60 min/d. Mean energy costs for the NOE, IKE, and ITE regimens were determined. Body densities within groups and mean urine volumes between groups were unchanged during BR. Changes in red cell volume followed changes in plasma volume. There was close coupling between resting plasma volume and plasma protein and osmotic content. It is argued that the ITE training protocol is better than the IKE protocol for maintaining plasma volume during prolonged exposure to BR.
Effects of FlAsH/Tetracysteine (TC) tag on PrP proteolysis and PrPres formation by TC-scanning
Taguchi, Yuzuru; Hohsfield, Lindsay A.; Hollister, Jason R.
2014-01-01
The FlAsH/tetracysteine (FlAsH/TC) tag is a powerful tool for fluorescent labeling of proteins. However, even small tags such as FlAsH/TC could alter the behavior of the tagged proteins, especially if the insertion occurs at internal sites. Defining the influence of FlAsH/TC on nearby protein-protein interactions might aid in selecting appropriate positions for internal TC insertions and allow the exploitation of serial FlAsH/TC insertions (TC-scanning) as a probe to characterize sites of protein-protein interaction. To explore this application in the context of substrate-protease interactions, we analyzed the effect of FlAsH/TC insertions on proteolysis of cellular prion protein (PrPsen) in in vitro reactions and generation of the C1 metabolic fragment of PrPsen in live neuroblastoma cells. The influence of FlAsH/TC insertion was evaluated by TC-scanning across the cleavage sites of each protease. The results showed that FlAsH/TC inhibited protease cleavage only within limited ranges of the cleavage sites that varied from about 1 to 6 residues-wide depending on the protease, providing an estimate of the PrP residues interacting with each protease. TC-scanning was also used to probe a different type of protein-protein interaction, the conformational conversion of FlAsH-PrPsen to the prion disease-associated isoform, PrPres. PrP constructs with FlAsH/TC insertions at residues 90–96 but not 97–101 were converted to FlAsH-PrPres, identifying a boundary separating loosely versus compactly folded regions of PrPres. Our observations demonstrate that TC-scanning with the FlAsH/TC tag can be a versatile method for probing protein-protein interactions and folding processes. PMID:23943295
A fluorescent probe for ecstasy.
Masseroni, D; Biavardi, E; Genovese, D; Rampazzo, E; Prodi, L; Dalcanale, E
2015-08-18
A nanostructure formed by the insertion in silica nanoparticles of a pyrene-derivatized cavitand, which is able to specifically recognize ecstasy in water, is presented. The absence of effects from interferents and an efficient electron transfer process occurring after complexation of ecstasy, makes this system an efficient fluorescent probe for this popular drug.
ERIC Educational Resources Information Center
Hughes, Julie
2012-01-01
Initial Teacher Education (ITE) for the post-compulsory sector (PCE) in the UK is currently under review. Despite earlier plans to substantially increase the use of technology in ITE the Lifelong Learning UK (LLUK) consultation findings recommend that "we will expect that teachers do develop their skills in this area to a limited extent on a…
Jaafoura, Neirouz Ghannouchi; Thaljaoui, Wathek; Atig, Amira; Bouker, Ahmed; Khalifa, Mabrouk; Bahri, Fathi
2014-01-01
La granulomatose avec polyangéite, est une vascularite systémique rare qui touche avec prédilection les voies aériennes supérieures, les poumons et les reins. L'atteinte cutanéo-muqueuse ainsi que l'atteinte digestive ne sont pas inhabituelles mais elles sont rarement inaugurales de la maladie. Nous rapportons l'observation d'une femme âgée de 57 ans, ayant une granulomatose avec polyangéite multi-systémique avec comme premières manifestations une atteinte cutanéo-muqueuse à type de nécrose de la langue et d'ulcérations péri-anales ainsi que des rectorragies. La présence de signes radiologiques orientant vers une hémmorragie intra-alvéolaire, l'atteinte rénale, l'atteinte neurologique périphérique ainsi que la positivité des C-ANCA de type anti-PR3 ont permis de rattacher les manifestations dermatologiques à cette vascularite. Des manifestations cutanéo-muqueuses atypiques, au cours d'une granulomateuse avec polyangéite, doivent être connues par le clinicien pour un diagnostic et une prise en charge adéquate. PMID:25404981
Dewhirst, Sue; Pickett, Karen; Speller, Viv; Shepherd, Jonathan; Byrne, Jenny; Almond, Palo; Grace, Marcus; Hartwell, Debbie; Roderick, Paul
2014-09-01
Teachers are a key part of the wider public health workforce in England. We conducted a survey to find out how they are trained for this role during their initial teacher education (ITE). Between 2011 and 2012, we sent an online questionnaire to 220 ITE course managers and conducted semi-structured interviews with a purposive sample of 19 course managers to explore issues in more depth. The response rate to the questionnaire was 34% (n = 74). Although most of the course managers felt inclusion of health and well-being training in ITE was important, provision across courses was variable. Topics which are public health priorities [e.g. sex and relationships education (SRE) and drugs, alcohol and tobacco] were covered by fewer courses than other topics (e.g. child protection, emotional health and anti-bullying). Perceived barriers to training included lack of time and a belief that health and well-being were low priorities in educational policy. Not all of tomorrow's teachers are being adequately prepared for their role in helping to address public health priorities. Educational policy does not appear to be supporting the priorities of public health policy, and this is a key barrier to health promotion training in ITE. Keywords children, educational settings, health promotion. © Crown copyright 2013.
Jones, Heath G; Kan, Alan; Litovsky, Ruth Y
2016-01-01
This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.
Decreased Expression of the Aryl Hydrocarbon Receptor in Ocular Behcet's Disease
Wang, Chaokui; Ye, Zi; Kijlstra, Aize; Zhou, Yan; Yang, Peizeng
2014-01-01
Recent studies show that the aryl hydrocarbon receptor (AhR) is involved in immune responses. AhR is activated following interaction with its ligands, such as 6-formylindolo[3,2-b]carbazole (FICZ) and 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). In this study, we investigated the role of AhR activation by its endogenous ligands in the pathogenesis of ocular Behcet's disease (BD). The expression of AhR was significantly decreased in active BD patients as compared to inactive BD patients and normal controls. Both FICZ and ITE inhibited Th1 and Th17 polarization and induced the expression of IL-22 by PBMCs and by CD4+T cells in active BD patients and normal controls. Stimulation of purified CD4+T cells with FICZ or ITE caused a decreased expression of RORC, IL-17, IL-23R, and CCR6 and an increased phosphorylation of STAT3 and STAT5. The present study suggests that a decreased AhR expression is associated with disease activity in BD patients. The activation of AhR by either FICZ or ITE was able to inhibit Th1 and Th17 cell polarization. Further studies are needed to investigate whether modulation of AhR might be used in the treatment of BD. PMID:25045206
Chau, Tom; Loertscher, Laura
2018-01-01
Background : Teaching the practice of high-value care (HVC) is an increasingly important function of graduate medical education but best practices and long-term outcomes remain unknown. Objective : Whether a multimodal curriculum designed to address specific drivers of low-value care would affect resident attitudes, skills, and performance of HVC as tested by the Internal Medicine In-Training Exam (ITE). Methods : In 2012, we performed a baseline needs assessment among internal medicine residents at a community program regarding drivers of healthcare utilization. We then created a multimodal curriculum with online interactive worksheets, lectures, and faculty buy-in to target specific skills, knowledge, and culture deficiencies. Perceived drivers of care and performance on the Internal Medicine ITE were assessed yearly through 2016. Results : Fourteen of 27 (52%) residents completed the initial needs assessment while the curriculum was eventually seen by at least 24 of 27 (89%). The ITE was taken by every resident every year. Long-term, 3-year follow-up demonstrated persistent improvement in many drivers of utilization (patient requests, reliance on subspecialists, defensive medicine, and academic curiosity) and improvement with sustained high performance on the high-value component of the ITE. Conclusion : A multimodal curriculum targeting specific drivers of low-value care can change culture and lead to sustained improvement in the practice of HVC.
How does a probe inserted into the discharge influence the plasma structure?
NASA Astrophysics Data System (ADS)
Yordanov, D.; Lishev, St.; Shivarova, A.
2016-05-01
Shielding the bias applied to the probe by the sheath formed around it and determination of parameters of unperturbed plasmas are in the basis of the probe diagnostics. The results from a two-dimensional model of a discharge with a probe inserted in it show that the probe influences the spatial distribution of the plasma parameters in the entire discharge. The increase (although slight) in the electron temperature, due to the increased losses of charged particles on the additional wall in the discharge (mainly the probe holder), leads to redistribution of the plasma density and plasma potential, as shown by the results obtained at the floating potential of the probe. The deviations due to the bias applied to the probe tip are stronger in the ion saturation region of the probe characteristics. The pattern of the spatial redistribution of the plasma parameters advances together with the movement of the probe deeper in the discharge. Although probe sheaths and probe characteristics resulting from the model are shown, the study does not aim at discussions on the theories for determination of the plasma density from the ion saturation current. Regardless of the modifications in the plasma behavior in the entire discharge, the deviations of the plasma parameters at the position of the probe tip and, respectively, the uncertainty which should be added as an error when the accuracy of the probe diagnostics is estimated do not exceed 10%. Consequently, the electron density and temperature obtained, respectively, at the position of the plasma potential on the probe characteristics and from its transition region are in reasonable agreement with the results from the model of the discharge without a probe. Being in the scope of research on a source of negative hydrogen ions with the design of a matrix of small radius inductive discharges, the model is specified for a low-pressure hydrogen discharge sustained in a small-radius tube.
Nicaise, C; Robert, C; Ancellin, J; Cazalaà, J B
1996-01-01
When plugging the O2, N2O and air hoses into the corresponding wall sockets, the air hose was wrongly inserted into the N2O wall outlet. This was made possible because of faulty retaining clasps of the male coupler of the air probe. French "fail-safe" connections consist of a two-clasp male coupler for air, three clasps for O2 and four clasps for N2O hoses. Additionally the clasps of the air probe are broader then those of the N2O probe. However, the latter difference was lost due to wear. The incident was recognized without delay as the N2O hose could not be inserted into the air outlet. However, it could have remained unnoticed had there been two N2O wall outlets and could have resulted in severe adverse effects.
NASA Astrophysics Data System (ADS)
Jia, Lihui; Liang, Shuang; Sackett, Kelly; Xie, Li; Ghosh, Ujjayini; Weliky, David P.
2015-04-01
Rotational-echo double-resonance (REDOR) solid-state NMR is applied to probe the membrane locations of specific residues of membrane proteins. Couplings are measured between protein 13CO nuclei and membrane lipid or cholesterol 2H and 31P nuclei. Specific 13CO labeling is used to enable unambiguous assignment and 2H labeling covers a small region of the lipid or cholesterol molecule. The 13CO-31P and 13CO-2H REDOR respectively probe proximity to the membrane headgroup region and proximity to specific insertion depths within the membrane hydrocarbon core. One strength of the REDOR approach is use of chemically-native proteins and membrane components. The conventional REDOR pulse sequence with 100 kHz 2H π pulses is robust with respect to the 2H quadrupolar anisotropy. The 2H T1's are comparable to the longer dephasing times (τ's) and this leads to exponential rather than sigmoidal REDOR buildups. The 13CO-2H buildups are well-fitted to A × (1 - e-γτ) where A and γ are fitting parameters that are correlated as the fraction of molecules (A) with effective 13CO-2H coupling d = 3γ/2. The REDOR approach is applied to probe the membrane locations of the "fusion peptide" regions of the HIV gp41 and influenza virus hemagglutinin proteins which both catalyze joining of the viral and host cell membranes during initial infection of the cell. The HIV fusion peptide forms an intermolecular antiparallel β sheet and the REDOR data support major deeply-inserted and minor shallowly-inserted molecular populations. A significant fraction of the influenza fusion peptide molecules form a tight hairpin with antiparallel N- and C-α helices and the REDOR data support a single peptide population with a deeply-inserted N-helix. The shared feature of deep insertion of the β and α fusion peptide structures may be relevant for fusion catalysis via the resultant local perturbation of the membrane bilayer. Future applications of the REDOR approach may include samples that contain cell membrane extracts and use of lower temperatures and dynamic nuclear polarization to reduce data acquisition times.
Kim, Hyun; Bar Ad, Voichita; McAna, John; Dicker, Adam P
2016-01-01
The yearly radiation oncology in-training examination (ITE) by the American College of Radiology is a widely used, norm-referenced educational assessment, with high test reliability and psychometric performance. We distributed a national survey to evaluate the academic radiation oncology community's perception of the ITE. In June 2014, a 7-question online survey was distributed via e-mail to current radiation oncology residents, program directors, and attending physicians who had completed residency in the past 5 years or junior attendings. Survey questions were designed on a 5-point Likert scale. Sign test was performed with P ≤ .05 considered statistically different from neutral. Thirty-one program directors (33.3%), 114 junior attendings (35.4%), and 225 residents (41.2%) responded. Junior attendings and program directors reported that the ITE directly contributed to their preparation for the American Board of Radiology written certification (P = .050 and .004, respectively). Residents did not perceive the examination as an accurate assessment of relevant clinical and scientific knowledge (P < .0001) and feel the quality assurance is insufficient in its current form (P < .0001). Residents and junior attendings agree that there are factual errors, and unclear questions/answers (P < .0001 and .04, respectively). Free response suggestions included: less questions on rare disease sites (16.4%), more relevance to clinical practice (15.4%), avoiding questions that discriminate between a few percentage points (11.8%), and designing the test similar to the written certification examination (9.2%). Despite high examination reliability and psychometric performance, resident and attending physicians report a need for improved quality assurance and clinical relevance in the ITE. Although the current examination allows limited feedback, establishing a venue for individualized feedback may allow continual and timely improvement of the ITE. Adopting a criterion-referenced examination may further increase resident investment in and utilization of this valuable learning tool. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lo, Meng-chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B.; Ahmed, Ijaz; Coffey, Kevin; Barker, David; Saste, Kshitij; Kals, Karanvir; Kaplan, Hilton M.; Kohn, Joachim; Shreiber, David I.; Zahn, Jeffrey D.
2018-06-01
Objective. Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device–tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. Approach. This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. Main results. Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm × 100 µm) and small probe (30 µm × 5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm × 200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm × 5 µm) to a smaller probe (30 µm × 5 µm) using the same polymer coating size (100 µm × 100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. Significance. These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.
Lo, Meng-Chen; Wang, Shuwu; Singh, Sagar; Damodaran, Vinod B; Ahmed, Ijaz; Coffey, Kevin; Barker, David; Saste, Kshitij; Kals, Karanvir; Kaplan, Hilton M; Kohn, Joachim; Shreiber, David I; Zahn, Jeffrey D
2018-06-01
Despite the feasibility of short-term neural recordings using implantable microelectrodes, attaining reliable, chronic recordings remains a challenge. Most neural recording devices suffer from a long-term tissue response, including gliosis, at the device-tissue interface. It was hypothesized that smaller, more flexible intracortical probes would limit gliosis by providing a better mechanical match with surrounding tissue. This paper describes the in vivo evaluation of flexible parylene microprobes designed to improve the interface with the adjacent neural tissue to limit gliosis and thereby allow for improved recording longevity. The probes were coated with an ultrafast degrading tyrosine-derived polycarbonate (E5005(2K)) polymer that provides temporary mechanical support for device implantation, yet degrades within 2 h post-implantation. A parametric study of probes of varying dimensions and polymer coating thicknesses were implanted in rat brains. The glial tissue response and neuronal loss were assessed from 72 h to 24 weeks post-implantation via immunohistochemistry. Experimental results suggest that both probe and polymer coating sizes affect the extent of gliosis. When an appropriate sized coating dimension (100 µm × 100 µm) and small probe (30 µm × 5 µm) was implanted, a minimal post-implantation glial response was observed. No discernible gliosis was detected when compared to tissue where a sham control consisting of a solid degradable polymer shuttle of the same dimensions was inserted. A larger polymer coating (200 µm × 200 µm) device induced a more severe glial response at later time points, suggesting that the initial insertion trauma can affect gliosis even when the polymer shuttle degrades rapidly. A larger degree of gliosis was also observed when comparing a larger sized probe (80 µm × 5 µm) to a smaller probe (30 µm × 5 µm) using the same polymer coating size (100 µm × 100 µm). There was no significant neuronal loss around the implantation sites for most device candidates except the group with largest polymer coating and probe sizes. These results suggest that: (1) the degree of mechanical trauma at device implantation and mechanical mismatches at the probe-tissue interface affect long term gliosis; (2) smaller, more flexible probes may minimize the glial response to provide improved tissue biocompatibility when used for chronic neural signal recording; and (3) some degree of glial scarring did not significantly affect neuronal distribution around the probe.
Brinkmann, B; May, D; Riemann, U
1976-06-30
Special thin and flexible thermometric probes showing a diameter of 1 mm and a sharp end were used for post mortem (p.m.) thermometric studies in several tissues. Brain temperatures were measured by inserting a double probe through the superior orbital fissura thus allowing to record the central and the peripheral brain regions separately. Another probe was inserted into the galea and a fourth into the liver. Temperature changes were recorded simultaneously. Many variables of the human head were measured. Sixteen corpses were investigated. The results were as follows: 1. Of all temperature curves registered those of the central brain regions showed the smallest variance. 2. The p.m. temperature curve of the brain shows a sigmoid shape with a rather short "plateau" in the beginning. 3. In the early p.m. phase there is an increasing difference of temperatures between central and peripheral brain regions amounting to 2-4, 6 degrees C in the time period between 78th and 128th minute. 4. The insertion of the thin probes does not cause visible damages. Thus it should be considered for use in forensic practice. 5. Some artificial "head models" were constructed and temperature decrease recorded after warming. The curves showed the same type of sigmoid shape as those obtained from the corpses. 6. Of the possible variables measured that could influence the temperature decrease only the density of the hair seems to be of interest.
Bénita, M; Condé, H; Dormont, J F; Schmied, A
1979-02-15
Five cats were trained to perform a forelimb ballistic flexion on a reaction time paradigm including an upper limit of about 400 ms for reinforcement (food pellets). They were implanted with a cyrogenic probe thermically insulated, except at the tip, by a vacuum jacket (outer diameter, 1.1 mm). Four cats had the probe inserted into the ventrolateral thalamic nucleus (VL), contralateral to the moving limb. During cooling they showed increased reaction times, which remained constant throughout daily sessions performed during many weeks, independent of the foreperiod but varying from 25 to 100 ms according to the subject. The temperatures used to upset the reaction times varied from +10 decrees C to -8 degrees C, depending on the localisation of the probe and on the insulation of the silver tip used to prevent nervous tissue reaction, but for each subject the reaction times always increased when the temperature was lowered. The fifth cat, with a probe inserted between VL and the Centre Median, showed a decrease of reaction times on cooling to 0 degrees C and an increase of the reaction times for a cooling at -10 degrees C. For one of the four cats with a probe properly inserted into the VL, strain-gauges were stuck on the lever to measure the latency of the decrease of the pressure exerted by the subject when the subject initiated the forelimb flexion in response to the CS. Reaction times and latencies of pressure changes were closely correlated with the movement onset, and they were equally delayed during cooling. This result demonstrates that it is not by slowing down movement velocity that reaction times are upset during VL cooling but by delaying the movement onset.
Safety and efficiency of the new micro-multiplane transoesophageal probe in paediatric cardiology.
Hascoët, Sébastien; Peyre, Marianne; Hadeed, Khaled; Alacoque, Xavier; Chausseray, Gérald; Fesseau, Rose; Amadieu, Romain; Léobon, Bertrand; Berthomieu, Lionel; Dulac, Yves; Acar, Philippe
2014-01-01
Transoesophageal echocardiography (TOE) is feasible in neonates using a miniaturized probe, but is not widely used because of low imaging quality. To assess handling and imaging quality of a new release of a micro-TOE probe in children. Thirty-eight consecutive children, enrolled during February and May 2013, underwent TOE with the Philips S8-3t probe. Insertion, handling and image quality were assessed. The 38 children (aged 7days to 12years; weight 3.1-27kg) underwent 75 TOE (30 [40.0%] before cardiac surgery, 31 [41.3%] after cardiac surgery, 4 [5.3%] during a percutaneous procedure, 10 [13.3%] in the intensive care unit). Insertion of the micro-TOE probe was 'very easy' in 37/38 patients (97.4%). Handling was better in the lightest children (P=0.001). Image quality was mainly 'good' or 'very good', with no significant changes between preoperative and postoperative examinations or over time. Total scores (insertion, handling, image quality) were significantly better in the lightest children (P=0.02). Preoperative TOE did not provide additional information over transthoracic echocardiography. Postoperative TOE was useful to assess surgical results, but no residual lesions required extracorporeal circulation return. Micro-TOE was useful during the postoperative care of neonatal surgery with open breastbone to assess the surgical result and ventricular function. It was also useful to guide extracorporeal membrane oxygenation (ECMO) indication and withdrawal; and was a useful guide for percutaneous procedures. Micro-multiplane TOE is safe and efficient for use in neonates and children. This minimally invasive tool increases the impact of TOE in paediatric cardiology. Copyright © 2014. Published by Elsevier Masson SAS.
Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J
2014-11-01
To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Ite Boerema--surgeon and engineer with a double-Dutch legacy to medical technology.
Leopardi, Lisa N; Metcalfe, Matthew S; Forde, Allison; Maddern, Guy J
2004-01-01
Ite Boerema, 1902-1978: a Dutchman with a brilliant academic surgical career, and war hero, decorated for resistance to the Germans in World War II. As a man who regarded surgery as "engineering in medicine," we still feel his legacy in medical technology today, specifically with regard to his work on esophageal anastomoses and hyperbaric oxygen therapy. This biography places his major contributions to medicine in context of the man himself and of contemporary medicine.
Use of molecular probes to detect parasites and retrotransposons in gypsy moths
John H. Werren; Thomas O' Dell
1991-01-01
Retrotransposon screen: Gypsy moth families containing straggling and nonstraggling individuals were divided into categories of straggling, medium, and nonstraggling individuals, from which DNA was extracted. Four families were tested by southern hybridization and probing with ribosomal sequences designed to detect R1 and R2 retrotransposon insertions. Results showed...
Gray, Joe W.; Pinkel, Daniel; Kallioniemi, Olli-Pekka; Kallioniemi, Anne; Sakamoto, Masaru
2009-10-06
Methods and compositions for staining based upon nucleic acid sequence that employ nudeic nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyses. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML), retinoblastoma, ovarian and uterine cancers, and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.
EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.
Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido
2010-01-01
To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.
NASA Astrophysics Data System (ADS)
Jung, C. C.; Stumpe, J.
2014-09-01
The capability of the method of immersion transmission ellipsometry (ITE) (Jung et al. Int Patent WO, 2004/109260) to not only determine three-dimensional refractive indices in anisotropic thin films (which was already possible in the past), but even their gradients along the z-direction (perpendicular to the film plane) is investigated in this paper. It is shown that the determination of orientation gradients in deep-sub-μm films becomes possible by applying ITE in combination with reflection ellipsometry. The technique is supplemented by atomic force microscopy for measuring the film thickness. For a photo-oriented thin film, no gradient was found, as expected. For a photo-oriented film, which was subsequently annealed in a nematic liquid crystalline phase, an order was found similar to the one applied in vertically aligned nematic displays, with a tilt angle varying along the z-direction. For fresh films, gradients were only detected for the refractive index perpendicular to the film plane, as expected.
An Intrathermocline Eddy and a tropical cyclone in the Bay of Bengal
NASA Astrophysics Data System (ADS)
Gordon, Arnold L.; Shroyer, Emily; Murty, V. S. N.
2017-04-01
The Bay of Bengal, subjected to monsoonal forcing and tropical cyclones, displays a complex field of ocean eddies. On 5 December 2013 a sub-surface vortex or Intrathermocline Eddy (ITE) composed of water characteristic of the Andaman Sea was observed within the thermocline of the western Bay of Bengal. We propose that the ITE was the product of Tropical Cyclone Lehar interaction on 27 November 2013 with a westward propagating surface eddy from the eastern Bay of Bengal. While Lehar’s interaction with the ocean initially removes heat from the upper layers of the eddy, air-sea flux is limited as the deeper portions of the eddy was subducted into the stratified thermocline, inhibiting further interaction with the atmosphere. The ITE core from 30 to 150 m is thus isolated from local air-sea fluxes by strong stratification at the mixed layer base, and its periphery is stable to shear instability, suggestive of longevity and the ability to carry water far distances with minimal modification.
An Intrathermocline Eddy and a tropical cyclone in the Bay of Bengal.
Gordon, Arnold L; Shroyer, Emily; Murty, V S N
2017-04-12
The Bay of Bengal, subjected to monsoonal forcing and tropical cyclones, displays a complex field of ocean eddies. On 5 December 2013 a sub-surface vortex or Intrathermocline Eddy (ITE) composed of water characteristic of the Andaman Sea was observed within the thermocline of the western Bay of Bengal. We propose that the ITE was the product of Tropical Cyclone Lehar interaction on 27 November 2013 with a westward propagating surface eddy from the eastern Bay of Bengal. While Lehar's interaction with the ocean initially removes heat from the upper layers of the eddy, air-sea flux is limited as the deeper portions of the eddy was subducted into the stratified thermocline, inhibiting further interaction with the atmosphere. The ITE core from 30 to 150 m is thus isolated from local air-sea fluxes by strong stratification at the mixed layer base, and its periphery is stable to shear instability, suggestive of longevity and the ability to carry water far distances with minimal modification.
Yeste, Ada; Nadeau, Meghan; Burns, Evan J.; Weiner, Howard L.; Quintana, Francisco J.
2012-01-01
The immune response is normally controlled by regulatory T cells (Tregs). However, Treg deficits are found in autoimmune diseases, and therefore the induction of functional Tregs is considered a potential therapeutic approach for autoimmune disorders. The activation of the ligand-activated transcription factor aryl hydrocarbon receptor by 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) or other ligands induces dendritic cells (DCs) that promote FoxP3+ Treg differentiation. Here we report the use of nanoparticles (NPs) to coadminister ITE and a T-cell epitope from myelin oligodendrocyte glycoprotein (MOG)35–55 to promote the generation of Tregs by DCs. NP-treated DCs displayed a tolerogenic phenotype and promoted the differentiation of Tregs in vitro. Moreover, NPs carrying ITE and MOG35–55 expanded the FoxP3+ Treg compartment and suppressed the development of experimental autoimmune encephalomyelitis, an experimental model of multiple sclerosis. Thus, NPs are potential new tools to induce functional Tregs in autoimmune disorders. PMID:22745170
An Intrathermocline Eddy and a tropical cyclone in the Bay of Bengal
Gordon, Arnold L.; Shroyer, Emily; Murty, V. S. N.
2017-01-01
The Bay of Bengal, subjected to monsoonal forcing and tropical cyclones, displays a complex field of ocean eddies. On 5 December 2013 a sub-surface vortex or Intrathermocline Eddy (ITE) composed of water characteristic of the Andaman Sea was observed within the thermocline of the western Bay of Bengal. We propose that the ITE was the product of Tropical Cyclone Lehar interaction on 27 November 2013 with a westward propagating surface eddy from the eastern Bay of Bengal. While Lehar’s interaction with the ocean initially removes heat from the upper layers of the eddy, air-sea flux is limited as the deeper portions of the eddy was subducted into the stratified thermocline, inhibiting further interaction with the atmosphere. The ITE core from 30 to 150 m is thus isolated from local air-sea fluxes by strong stratification at the mixed layer base, and its periphery is stable to shear instability, suggestive of longevity and the ability to carry water far distances with minimal modification. PMID:28401909
NASA Astrophysics Data System (ADS)
Shallcross, Tony; Spink, Elaine; Stephenson, Philip; Warwick, Paul
2002-12-01
The significance of subject knowledge in the education of science teachers is much debated nationally and internationally. Part of this debate is about what the term 'science subject knowledge' means. This paper examines two UK research studies, one from Manchester Metropolitan University (MMU) and one from Homerton College, Cambridge, into initial teacher education (ITE) trainees' confidence with their science knowledge. Both surveys revealed the importance of school experience in developing this knowledge. The MMU survey also identified a disproportionate requirement being placed on trainees to teach particular science topics in schools. The paper discusses the implications of these surveys for the design of ITE primary core science programmes in the UK and raises questions about current approaches to the assessment of trainees' subject knowledge in ITE, which are of generic interest. How do we verify trainees' mastery of content? Does such mastery equate with competent teaching? Answers to both questions are proposed.
Physical mapping of complex genomes
Evans, G.A.
1993-06-15
A method for the simultaneous identification of overlapping cosmid clones among multiple cosmid clones and the use of the method for mapping complex genomes are provided. A library of cosmid clones that contains the DNA to be mapped is constructed and arranged in a manner such that individual clones can be identified and replicas of the arranged clones prepared. In preferred embodiments, the clones are arranged in a two dimensional matrix. In such embodiments, the cosmid clones in a row are pooled, mixed probes complementary to the ends of the DNA inserts in the pooled clones are synthesized, hybridized to a first replica of the library. Hybridizing clones, which include the pooled row, are identified. A second portion of clones is prepared by pooling cosmid clones that correspond to a column in the matrix. The second pool thereby includes one clone from the first portion pooled clones. This common clone is located on the replica at the intersection of the column and row. Mixed probes complementary to the ends of the DNA inserts in the second pooled portion of clones are prepared and hybridized to a second replica of the library. The hybridization pattern on the first and second replicas of the library are compared and cross-hybridizing clones, other than the clones in the pooled column and row, that hybridize to identical clones in the first and second replicas are identified. These clones necessarily include DNA inserts that overlap with the DNA insert in the common clone located at the intersection of the pooled row and pooled column. The DNA in the entire library may be mapped by pooling the clones in each of the rows and columns of the matrix, preparing mixed end-specific probes and hybridizing the probes from each row or column to a replica of the library. Since all clones in the library are located at the intersection of a column and a row, the overlapping clones for all clones in the library may be identified and a physical map constructed.
Intensive exercise training suppresses testosterone during bed rest
NASA Technical Reports Server (NTRS)
Wade, C. E.; Stanford, K. I.; Stein, T. P.; Greenleaf, J. E.
2005-01-01
Spaceflight and prolonged bed rest (BR) alter plasma hormone levels inconsistently. This may be due, in part, to prescription of heavy exercise as a countermeasure for ameliorating the adverse effects of disuse. The initial project was to assess exercise programs to maintain aerobic performance and leg strength during BR. The present study evaluates the effect of BR and the performance of the prescribed exercise countermeasures on plasma steroid levels. In a 30-day BR study of male subjects, the efficacy of isotonic (ITE, n = 7) or isokinetic exercise (IKE, n = 7) training was evaluated in contrast to no exercise (n = 5). These exercise countermeasures protected aerobic performance and leg strength successfully. BR alone (no-exercise group) did not change steroidogenesis, as assessed by the plasma concentrations of cortisol, progesterone, aldosterone, and free (FT) and total testosterone (TT). In the exercise groups, both FT and TT were decreased (P < 0.05): FT during IKE from 24 +/- 1.7 to 18 +/- 2.0 pg/ml and during ITE from 21 +/- 1.5 to 18 +/- 1 pg/ml, and TT during IKE from 748 +/- 68 to 534 +/- 46 ng/dl and during ITE from 565 +/- 36 to 496 +/- 38 ng/dl. The effect of intensive exercise countermeasures on plasma testosterone was not associated with indexes of overtraining. The reduction in plasma testosterone associated with both the IKE and ITE countermeasures during BR supports our hypothesis that intensive exercise countermeasures may, in part, contribute to changes in plasma steroid concentrations during spaceflight.
Benefits of interval-training on fatigue and functional capacities in Charcot-Marie-Tooth disease.
El Mhandi, Lhassan; Millet, Guillaume Y; Calmels, Paul; Richard, Antoine; Oullion, Roger; Gautheron, Vincent; Féasson, Léonard
2008-05-01
Exercise intolerance and undue fatigue are common complaints in patients with Charcot-Marie-Tooth (CMT) disease. Reduced physical ability is due directly to the disease, but it is also due to physical deconditioning. The aim of this study was to test whether 24 weeks of interval-training exercise (ITE) cycling can significantly improve physiological, neuromuscular, and functional capacities and alleviate fatigue in CMT patients. Eight CMT patients (4 CMT1A and 4 CMT2) participated in ITE for 3 nonconsecutive days per week. Cardiovascular fitness, muscle strength, fatigue resistance, and functional capacities were measured before and after 12 weeks of supervised hospital training and again after another 12 weeks of unsupervised home training. Training was well tolerated. There were significant improvements in cardiorespiratory capacities, isokinetic concentric strength, and functional ability measurements. All patients experienced an improvement in their self-reported visual analogic scale for fatigue and pain during training. However, there was no significant change in their isometric force production and indices of fatigue resistance after training. Although the improvement in exercise tolerance may be due in part to reversal of the deconditioning effect of their related sedentary lifestyle, this clinical trial suggests that ITE can benefit CMT patients especially in their functional performance and subjective perception of pain and fatigue. Moreover, the improvement observed at the end of the first supervised period ITE was maintained after the second unsupervised home period, although there was no further improvement in performance and tolerance.
Schoemaker, Joep H; Vingerhoets, Ad J J M; Emsley, Robin A
2018-06-05
IntroductionDespite consistently high discontinuation rates due to withdrawal of consent (WOC) and insufficient therapeutic effect (ITE) in schizophrenia trials, insight into the underlying factors contributing to poor satisfaction with treatment and dropout is limited. A better understanding of these factors could help to improve trial design and completion rates. Using data from 1,136 trial participants with schizophrenia or schizoaffective disorder, we explored associations between predictor variables with (1) dropout due to WOC and ITE and (2) satisfaction with treatment among patients and investigators by means of hierarchic multiple regression analyses. ITE was associated with poor clinical improvement, poor investigator satisfaction with treatment, and poor patient insight into their own disease, whereas WOC only showed a meaningful association with poor patient satisfaction with treatment. Investigator satisfaction with treatment appeared most strongly associated with Positive and Negative Syndrome Scale (PANSS) positive factor endpoint scores, whereas patient satisfaction with treatment was best predicted by the endpoint score on the PANSS emotional distress factor. The occurrence of severe side effects showed no meaningful association to satisfaction with treatment among investigators and patients, and neither did a patient's experienced psychopathology, nor their self-rating of functional impairment. Whereas trial discontinuation due to ITE is associated with poor treatment effectiveness, a patient's decision to withdraw from an antipsychotic trial remains unpredictable and may occur even when the investigator observes a global clinical improvement and is satisfied with the treatment.
Kumar, Ashok; Griwan, Mahavir Singh; Singh, Santosh Kumar; Sen, Jyotsna; Pawar, D. S.
2013-01-01
Introduction: Controversy exists over the pain during prostate biopsy. Periprostatic nerve block (PNB) is a gold standard anesthetic technique during transrectal ultrasound (TRUS)-guided prostate biopsy. Recent studies showed that PNB alone is insufficient as analgesic. We compared the efficacy of tramadol and intraprostatic nerve block (INB) in addition to PNB. Materials and Methods: We conducted a prospective double blinded placebo controlled study at our institute in 150 consecutive patients. Patients were randomized into three groups. Group A received PNB with INB with 1% lignocaine. Group B received oral tramadol with PNB. Group C patients were administered PNB only with 1% lignocaine. Patients were asked to grade the pain level using 11 point linear visual analog scale (VAS) at the time of ultrasound probe insertion, at time of anesthesia, during biopsy, and 30 min after biopsy. Results: The study groups were comparable in demographic profile, prostate-specific antigen (PSA) levels, and prostate size. Group A recorded the minimum mean pain score of 2.66 during prostate biopsy which was significantly lower than group 3 (P < 0.001). Group B recorded significantly lower pain score at time of probe insertion and at anesthetic needle insertion than other two groups. Conclusions: PNB provides better pain control in TRUS-guided prostate biopsy but still there is need of additional analgesic in the form of tramadol or INB. Tramadol has advantage of oral intake and analgesic effect at time of probe insertion and at nerve block. Both tramadol and INB may be used in combination along with PNB. PMID:24049376
Intracranial surgical operative apparatus
NASA Technical Reports Server (NTRS)
Sheldon, Charles H. (Inventor); Frazer, Robert E. (Inventor); Lutes, Harold R. (Inventor)
1983-01-01
Apparatus for operating on the brain with minimal disturbances thereto, including a bullet-shaped expandable device with an end that can be closed for insertion through a small hole in the brain. The device can be expanded after insertion to leave an air pocket through which to extend viewing and cutting devices which enable operation on tumors or the like that lie at the end of the expanded device. A set of probes of varying diameters are also provided, to progressively enlarge a passage leading to the tumor, prior to inserting the expandable device.
Cold cathode vacuum discharge tube
Boettcher, Gordon E.
1998-01-01
A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging.
Insect-machine interface based neurocybernetics.
Bozkurt, Alper; Gilmour, Robert F; Sinha, Ayesa; Stern, David; Lal, Amit
2009-06-01
We present details of a novel bioelectric interface formed by placing microfabricated probes into insect during metamorphic growth cycles. The inserted microprobes emerge with the insect where the development of tissue around the electronics during the pupal development allows mechanically stable and electrically reliable structures coupled to the insect. Remarkably, the insects do not react adversely or otherwise to the inserted electronics in the pupae stage, as is true when the electrodes are inserted in adult stages. We report on the electrical and mechanical characteristics of this novel bioelectronic interface, which we believe would be adopted by many investigators trying to investigate biological behavior in insects with negligible or minimal traumatic effect encountered when probes are inserted in adult stages. This novel insect-machine interface also allows for hybrid insect-machine platforms for further studies. As an application, we demonstrate our first results toward navigation of flight in moths. When instrumented with equipment to gather information for environmental sensing, such insects potentially can assist man to monitor the ecosystems that we share with them for sustainability. The simplicity of the optimized surgical procedure we invented allows for batch insertions to the insect for automatic and mass production of such hybrid insect-machine platforms. Therefore, our bioelectronic interface and hybrid insect-machine platform enables multidisciplinary scientific and engineering studies not only to investigate the details of insect behavioral physiology but also to control it.
Pillai, Krishna; Al-Alem, Ihssan; Akhter, Javed; Chua, Terence C; Shehata, Mena; Morris, David L
2015-06-01
Percutaneous bipolar radiofrequency ablation (RFA) is a minimally invasive technique for treating liver tumors. It is not always possible to insert the bipolar probes parallel to each other on either side of tumor, since it restricts maneuverability away from vital structures or ablate certain tumor shape. Therefore, we investigated how nonparallel placement of probes affected ablation. Bipolar RFA in parallel and in divergent positions were submerged in tissue model (800 mL egg white) at 37°C and ablated. Temperature probes, T1 and T2 were placed 8.00 mm below the tip of the probes, T3 in between the probe coil elements and T4 and T5 at water inlet and outlet, respectively. Both models with heat sink (+HS) and without (-HS) were investigated. The mean ablated tissue volume, mass, density and height increased linearly with unit angle increase for -HS model. With +HS, a smaller increase in mean volume and mass, a slightly greater increase in mean density but a reduction in height of tissue was seen. The mean ablation time and duration of maximum temperature with +HS was slightly larger, compared with -HS, while -HS ablated at a slightly higher temperature. The heat sink present was minimal for probes in parallel position compared to nonparallel positions. Divergence from parallel insertion of bipolar RFA probes increased the mean volume, mass, and density of tissue ablated. However, the presence of large heat sinks may limit the application of this technique, when tumors border on larger vessels. © The Author(s) 2014.
The vector homology problem in diagnostic nucleic acid hybridization of clinical specimens.
Ambinder, R F; Charache, P; Staal, S; Wright, P; Forman, M; Hayward, S D; Hayward, G S
1986-01-01
Nucleic acid hybridization techniques using cloned probes are finding application in assays of clinical specimens in research and diagnostic laboratories. The probes that we and others have used are recombinant plasmids composed of viral inserts and bacterial plasmid vectors such as pBR322. We suspected that there was material homologous to pBR322 present in many clinical samples. because hybridization occurred in samples which lacked evidence of virus by other techniques. If the presence of this vector-homologous material was unrecognized, hybridization in the test sample might erroneously be interpreted as indicating the presence of viral sequences. In this paper we demonstrate specific hybridization of labeled pBR322 DNA with DNA from various clinical samples. Evidence is presented that nonspecific probe trapping could not account for this phenomenon. In mixing experiments, it is shown that contamination of clinical samples with bacteria would explain such a result. Approaches tested to circumvent this problem included the use of isolated insert probes, alternate cloning vectors, and cold competitor pBR322 DNA in prehybridization and hybridization mixes. None proved entirely satisfactory. We therefore emphasize that it is essential that all hybridization detection systems use a control probe of the vector alone in order to demonstrate the absence of material with vector homology in the specimen tested. Images PMID:3013928
Directivity and noise reduction in hearing aids: speech perception and benefit.
Quintino, Camila Angélica; Mondelli, Maria Fernanda Capoani Garcia; Ferrari, Déborah Viviane
2010-01-01
Hearing aid. To compare the performance, benefit and satisfaction of users of ITE, CIC and BTE digital hearing aid with noise reduction and omnidirectional and directional microphones. 34 users of hearing aid were evaluated by means of speech perception in noise tests and APHAB and IOI self assessment questionnaires. Prospective study. Better results were obtained by users of ITE, CIC and directional hearing aids, however, no statistical significance was found between the groups. Directivity improved speech perception in noise and benefit in daily life situations.
Cold cathode vacuum discharge tube
Boettcher, G.E.
1998-03-10
A cold cathode vacuum discharge tube, and method for making same, are disclosed with an interior surface of the trigger probe coated with carbon deposited by carbon vapor deposition (CVD) or diamond-like carbon (DLC) deposition. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 15 figs.
Cold cathode vacuum discharge tube
Boettcher, G.E.
1998-04-14
A cold cathode vacuum discharge tube, and method for making same, with an interior surface of the trigger probe coated with carbon deposited by chemical vapor deposition (CVD) or diamond-like carbon (DLC) deposition are disclosed. Preferably a solid graphite insert is employed in the probe-cathode structure in place of an aluminum bushing employed in the prior art. The CVD or DLC probe face is laser scribed to allow resistance trimming to match available trigger voltage signals and to reduce electrical aging. 14 figs.
Starter for inductively coupled plasma tube
Hull, Donald E.; Bieniewski, Thomas M.
1988-01-01
A starter assembly is provided for use with an inductively coupled plasma (ICP) tube to reliably initate a plasma at internal pressures above about 30 microns. A conductive probe is inserted within the inductor coil about the tube and insulated from the tube shield assembly. A capacitive circuit is arranged for momentarily connecting a high voltage radio-frequency generator to the probe while simultaneously energizing the coil. When the plasma is initiated the probe is disconnected from the generator and electrically connected to the shield assembly for operation.
Micro-optical fiber probe for use in an intravascular Raman endoscope.
Komachi, Yuichi; Sato, Hidetoshi; Aizawa, Katsuo; Tashiro, Hideo
2005-08-01
We believe that we have developed the narrowest optical-fiber Raman probe ever reported, 600 microm in total diameter, that can be inserted into coronary arteries. The selection of suitable optical fibers, filters, and a processing method is discussed. Custom-made filters attached to the front end of a probe eliminate the background Raman signals of the optical fiber itself. The experimental evaluation of various optical fibers is carried out for the selection of suitable fibers. Measurement of the Raman spectra of an atherosclerotic lesion of a rabbit artery in vitro demonstrates the excellent performance of the micro-Raman probe.
SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues.
Tijero, M; Gabriel, G; Caro, J; Altuna, A; Hernández, R; Villa, R; Berganzo, J; Blanco, F J; Salido, R; Fernández, L J
2009-04-15
This paper presents a minimally invasive needle-shaped probe capable of monitoring the electrical impedance of living tissues. This microprobe consists of a 160 microm thick SU-8 substrate containing four planar platinum (Pt) microelectrodes. We design the probe to minimize damage to the surrounding tissue and to be stiff enough to be inserted in living tissues. The proposed batch fabrication process is low cost and low time consuming. The microelectrodes obtained with this process are strongly adhered to the SU-8 substrate and their impedance does not depend on frequency variation. In vitro experiments are compared with previously developed Si and SiC based microprobes and results suggest that it is preferable to use the SU-8 based microprobes due to their flexibility and low cost. The microprobe is assembled on a flexible printed circuit FPC with a conductive glue, packaged with epoxy and wired to the external instrumentation. This flexible probe is inserted into a rat kidney without fracturing and succeeds in demonstrating the ischemia monitoring.
A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy.
Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V
2012-10-08
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.
A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy
Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.
2012-01-01
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope’s instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. PMID:23188360
Cobra Probes Containing Replaceable Thermocouples
NASA Technical Reports Server (NTRS)
Jones, John; Redding, Adam
2007-01-01
A modification of the basic design of cobra probes provides for relatively easy replacement of broken thermocouples. Cobra probes are standard tube-type pressure probes that may also contain thermocouples and that are routinely used in wind tunnels and aeronautical hardware. They are so named because in side views, they resemble a cobra poised to attack. Heretofore, there has been no easy way to replace a broken thermocouple in a cobra probe: instead, it has been necessary to break the probe apart and then rebuild it, typically at a cost between $2,000 and $4,000 (2004 prices). The modified design makes it possible to replace the thermocouple, in minimal time and at relatively low cost, by inserting new thermocouple wire in a tube.
USSR Report, Electronics and Electrical Engineering, No. 102
1983-04-29
S. IAbstract] The laser probing method is applied to measurement of absorption , transmission, and reflection coefficients, also insertion losses...electronic clock. The method of measurements is based on absorption of monochromatic radiation from the lasers, the latter being tuned to the fine...Acoustic-Wave Transducer by Laser Probing Method (A. B. Voroshnin, G. S. Felinskiy; IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENIY: RADIOELEKTRONIKA, Dec 82
Z-DNA binding protein from chicken blood nuclei
NASA Technical Reports Server (NTRS)
Herbert, A. G.; Spitzner, J. R.; Lowenhaupt, K.; Rich, A.
1993-01-01
A protein (Z alpha) that appears to be highly specific for the left-handed Z-DNA conformer has been identified in chicken blood nuclear extracts. Z alpha activity is measured in a band-shift assay by using a radioactive probe consisting of a (dC-dG)35 oligomer that has 50% of the deoxycytosines replaced with 5-bromodeoxycytosine. In the presence of 10 mM Mg2+, the probe converts to the Z-DNA conformation and is bound by Z alpha. The binding of Z alpha to the radioactive probe is specifically blocked by competition with linear poly(dC-dG) stabilized in the Z-DNA form by chemical bromination but not by B-form poly(dC-dG) or boiled salmon-sperm DNA. In addition, the binding activity of Z alpha is competitively blocked by supercoiled plasmids containing a Z-DNA insert but not by either the linearized plasmid or by an equivalent amount of the parental supercoiled plasmid without the Z-DNA-forming insert. Z alpha can be crosslinked to the 32P-labeled brominated probe with UV light, allowing us to estimate that the minimal molecular mass of Z alpha is 39 kDa.
The iterative thermal emission method: A more implicit modification of IMC
NASA Astrophysics Data System (ADS)
Long, A. R.; Gentile, N. A.; Palmer, T. S.
2014-11-01
For over 40 years, the Implicit Monte Carlo (IMC) method has been used to solve challenging problems in thermal radiative transfer. These problems typically contain regions that are optically thick and diffusive, as a consequence of the high degree of ;pseudo-scattering; introduced to model the absorption and reemission of photons from a tightly-coupled, radiating material. IMC has several well-known features that could be improved: a) it can be prohibitively computationally expensive, b) it introduces statistical noise into the material and radiation temperatures, which may be problematic in multiphysics simulations, and c) under certain conditions, solutions can be nonphysical, in that they violate a maximum principle, where IMC-calculated temperatures can be greater than the maximum temperature used to drive the problem. We have developed a variant of IMC called iterative thermal emission IMC, which is designed to have a reduced parameter space in which the maximum principle is violated. ITE IMC is a more implicit version of IMC in that it uses the information obtained from a series of IMC photon histories to improve the estimate for the end of time step material temperature during a time step. A better estimate of the end of time step material temperature allows for a more implicit estimate of other temperature-dependent quantities: opacity, heat capacity, Fleck factor (probability that a photon absorbed during a time step is not reemitted) and the Planckian emission source. We have verified the ITE IMC method against 0-D and 1-D analytic solutions and problems from the literature. These results are compared with traditional IMC. We perform an infinite medium stability analysis of ITE IMC and show that it is slightly more numerically stable than traditional IMC. We find that significantly larger time steps can be used with ITE IMC without violating the maximum principle, especially in problems with non-linear material properties. The ITE IMC method does however yield solutions with larger variance because each sub-step uses a different Fleck factor (even at equilibrium).
The iterative thermal emission method: A more implicit modification of IMC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, A.R., E-mail: arlong.ne@tamu.edu; Gentile, N.A.; Palmer, T.S.
2014-11-15
For over 40 years, the Implicit Monte Carlo (IMC) method has been used to solve challenging problems in thermal radiative transfer. These problems typically contain regions that are optically thick and diffusive, as a consequence of the high degree of “pseudo-scattering” introduced to model the absorption and reemission of photons from a tightly-coupled, radiating material. IMC has several well-known features that could be improved: a) it can be prohibitively computationally expensive, b) it introduces statistical noise into the material and radiation temperatures, which may be problematic in multiphysics simulations, and c) under certain conditions, solutions can be nonphysical, in thatmore » they violate a maximum principle, where IMC-calculated temperatures can be greater than the maximum temperature used to drive the problem. We have developed a variant of IMC called iterative thermal emission IMC, which is designed to have a reduced parameter space in which the maximum principle is violated. ITE IMC is a more implicit version of IMC in that it uses the information obtained from a series of IMC photon histories to improve the estimate for the end of time step material temperature during a time step. A better estimate of the end of time step material temperature allows for a more implicit estimate of other temperature-dependent quantities: opacity, heat capacity, Fleck factor (probability that a photon absorbed during a time step is not reemitted) and the Planckian emission source. We have verified the ITE IMC method against 0-D and 1-D analytic solutions and problems from the literature. These results are compared with traditional IMC. We perform an infinite medium stability analysis of ITE IMC and show that it is slightly more numerically stable than traditional IMC. We find that significantly larger time steps can be used with ITE IMC without violating the maximum principle, especially in problems with non-linear material properties. The ITE IMC method does however yield solutions with larger variance because each sub-step uses a different Fleck factor (even at equilibrium)« less
Pan, Pan; Hong, Bo; Mbadinga, Serge Maurice; Wang, Li-Ying; Liu, Jin-Feng; Yang, Shi-Zhong; Gu, Ji-Dong; Mu, Bo-Zhong
2017-09-01
Acetate is a key intermediate in anaerobic crude oil biodegradation and also a precursor for methanogenesis in petroleum reservoirs. The impact of iron oxides, viz. β-FeOOH (akaganéite) and magnetite (Fe 3 O 4 ), on the methanogenic acetate metabolism in production water of a high-temperature petroleum reservoir was investigated. Methane production was observed in all the treatments amended with acetate. In the microcosms amended with acetate solely about 30% of the acetate utilized was converted to methane, whereas methane production was stimulated in the presence of magnetite (Fe 3 O 4 ) resulting in a 48.34% conversion to methane. Methane production in acetate-amended, β-FeOOH (akaganéite)-supplemented microcosms was much faster and acetate consumption was greatly improved compared to the other conditions in which the stoichiometric expected amounts of methane were not produced. Microbial community analysis showed that Thermacetogenium spp. (known syntrophic acetate oxidizers) and hydrogenotrophic methanogens closely related to Methanothermobacter spp. were enriched in acetate and acetate/magnetite (Fe 3 O 4 ) microcosms suggesting that methanogenic acetate metabolism was through hydrogenotrophic methanogenesis fueled by syntrophic acetate oxidizers. The acetate/β-FeOOH (akaganéite) microcosms, however, differed by the dominance of archaea closely related to the acetoclastic Methanosaeta thermophila. These observations suggest that supplementation of β-FeOOH (akaganéite) accelerated the production of methane further, driven the alteration of the methanogenic community, and changed the pathway of acetate methanogenesis from hydrogenotrophic methanogenesis fueled by syntrophic acetate oxidizers to acetoclastic.
NASA Astrophysics Data System (ADS)
Wang, Y.
2011-01-01
The direct topographic effect (DTE) and indirect topographic effect (ITE) of Helmert's 2
Khan, Abdur Rahman; Siddiqui, Nauman Saleem; Thotakura, Raja; Hasan, Syed Shafae; Luni, Faraz Khan; Sodeman, Thomas; Hinch, Bryan; Kaw, Dinkar; Hariri, Imad; Khuder, Sadik; Assaly, Ragheb
2015-01-01
In-training examination (ITE) has been used as a predictor of performance at the American Board of Internal Medicine (ABIM) certifying examination. ITE however may not be an ideal modality as it is held once a year and represents snapshots of performance as compared with a trend. We instituted monthly tests (MTs) to continually assess the performance of trainees throughout their residency. To determine the predictors of ABIM performance and to assess whether the MTs can be used as a tool to predict passing the ABIM examination. The MTs, core competencies, and ITE scores were analyzed for a cohort of graduates who appeared for the ABIM examination from 2010 to 2013. Logistic regression was performed to identify the predictors of a successful performance at the ABIM examination. Fifty-one residents appeared for the ABIM examination between 2010 and 2013 with a pass rate of 84%. The MT score for the first year (odds ratio [OR] =1.302, CI =1.004-1.687, P=0.04) and second year (OR =1.125, CI =1.004-1.261, P=0.04) were independent predictors of ABIM performance along with the second-year ITE scores (OR =1.248, CI =1.096-1.420, P=0.001). The MT is a valuable tool to predict the performance at the ABIM examination. Not only it helps in the assessment of likelihood of passing the certification examination, it also helps to identify those residents who may require more assistance earlier during their residency. It may also highlight the areas of weakness in program curriculum and guide curriculum development.
Cryogenic vacuumm RF feedthrough device
Wu, Genfa [Yorktown, VA; Phillips, Harry Lawrence [Hayes, VA
2008-12-30
A cryogenic vacuum rf feedthrough device comprising: 1) a probe for insertion into a particle beam; 2) a coaxial cable comprising an inner conductor and an outer conductor, a dielectric/insulating layer surrounding the inner conductor, the latter being connected to the probe for the transmission of higher mode rf energy from the probe; and 3) a high thermal conductivity stub attached to the coaxial dielectric about and in thermal contact with the inner conductor which high thermal conductivity stub transmits heat generated in the vicinity of the probe efficiently and radially from the area of the probe and inner conductor all while maintaining useful rf transmission line characteristics between the inner and outer coaxial conductors.
NASA Astrophysics Data System (ADS)
He, Wei; McConnell, George C.; Bellamkonda, Ravi V.
2006-12-01
Neural electrodes could significantly enhance the quality of life for patients with sensory and/or motor deficits as well as improve our understanding of brain functions. However, long-term electrical connectivity between neural tissue and recording sites is compromised by the development of astroglial scar around the recording probes. In this study we investigate the effect of a nanoscale laminin (LN) coating on Si-based neural probes on chronic cortical tissue reaction in a rat model. Tissue reaction was evaluated after 1 day, 1 week, and 4 weeks post-implant for coated and uncoated probes using immunohistochemical techniques to evaluate activated microglia/macrophages (ED-1), astrocytes (GFAP) and neurons (NeuN). The coating did not have an observable effect on neuronal density or proximity to the electrode surface. However, the response of microglia/macrophages and astrocytes was altered by the coating. One day post-implant, we observed an ~60% increase in ED-1 expression near LN-coated probe sites compared with control uncoated probe sites. Four weeks post-implant, we observed an ~20% reduction in ED-1 expression along with an ~50% reduction in GFAP expression at coated relative to uncoated probe sites. These results suggest that LN has a stimulatory effect on early microglia activation, accelerating the phagocytic function of these cells. This hypothesis is further supported by the increased mRNA expression of several pro-inflammatory cytokines (TNF-α, IL-1 and IL-6) in cultured microglia on LN-bound Si substrates. LN immunostaining of coated probes immediately after insertion and retrieval demonstrates that the coating integrity is not compromised by the shear force during insertion. We speculate, based on these encouraging results, that LN coating of Si neural probes could potentially improve chronic neural recordings through dispersion of the astroglial scar.
Silicon avalanche photodiodes developed at the Institute of Electron Technology
NASA Astrophysics Data System (ADS)
Wegrzecka, Iwona; Wegrzecki, Maciej; Bar, Jan; Grynglas, Maria; Uszynski, Andrzej; Grodecki, Remigiusz; Grabiec, Piotr B.; Krzeminski, Sylwester; Budzynski, Tadeusz
2004-07-01
Silicon avalanche photodiodes (APDs) -- due to the effect of avalanche multiplication of carriers in their structure -- are most sensitive and fastest detectors of visible and near infrared radiation. Also the value of noise equivalent power NEP of these detectors is the smallest. In the paper, the design, technology and properties of the silicon avalanche photodiodes with a n+ - p - π - p+ epiplanar structure developed at the Institute of Electron Technology (ITE) are presented. The diameters of photosensitive area range from 0.3 mm to 5 mm. The ITE photodiodes are optimized for the detection of the 800 nm - 850 nm radiation, but the detailed research on spectral dependencies of the gain and noise parameters has revealed that the spectral operating range of the ITE photodiodes is considerable wider and achieves 550 - 1000 nm. These photodiodes can be used in detection of very weak and very fast optical signals. Presently in the world, the studies are carried out on applying the avalanche photodiodes in detection of X radiation and in the scintillation detection of nuclear radiation.
Fragments of quartz monzodiorite and felsite in Apollo 14 soil particles
NASA Technical Reports Server (NTRS)
Jolliff, B. L.
1991-01-01
Samples of 'evolved' lithologies, felsite, quartz monzodiorite (QMD), and whitlockite-rich quartz monzodiorite, were identified compositionally and petrographically among 2-4-mm soil particles from Apollo 14. Fragments of QMD were found to be extremely rare in the Apollo 14 samples. Felsite is similar to previously reported samples. QMD 14161,7069 is similar to 15405 QMD and has ITE concentrations in KREEP-like concentration ratios of about twice the ITE concentrations of average high-K KREEP. QMD cumulate has the highest measured REE concentrations of any lunar sample to date with the exception of individual whitlockite grains. Felsite and whitlockite-rich lithologies appear to be petrogenetically related and have complementary compositions representing separated fractions of the QMD or KREEP-like parental melt. Felsite is a silica-rich fraction of the residual liquid or it is a derivative of the silica-rich fraction. Felsite or lunar granite of this type results from residual liquid separation following crystal-liquid separation of a QMD-like parent melt with concentration ratios of ITEs similar to those of KREEP.
Fighting the Russians in Winter: Three Case Studies (Leavenworth Papers, Number 5)
1981-12-01
e z s aya elve les rther e e nth ey led ro eir ilroad itions l l- e i lery, inly 75- s ned ite ssians. ey centrated l e ops ey ld e rom...ines een aya e ad itions, ter e rning ree ttalions e oscow iment lanked e lies e rth e pted ture o - s ro e . ieutenant kovsky, e ite...cal e ents s practical, tain itional ts e paign rthern ssia a rant tention r eir nical s. t aya llied t oops lived i erted ilroad cars. he i pro
Lackland Air Force Base Phase II Uniform Issue: Baseline Report
2011-05-01
Lectures on uniform wearing and care are given 1-2 ORGANIZATION The remainder of this report includes two...sp ec ts al te ra tio ns A pp ro ve d to U S A F sp ec ? Tr ai ne es p ac k ite m s in d uf fle Y es A ll ite m s in sp ec te d? In ve nt...First alteration Second alteration Third alteration Pe rc en ta ge o f t ro us er s al te re d 0% 10% 20% 30% 40% 50% 60% 70% 80%
Quality of life, burnout, educational debt, and medical knowledge among internal medicine residents.
West, Colin P; Shanafelt, Tait D; Kolars, Joseph C
2011-09-07
Physician distress is common and has been associated with negative effects on patient care. However, factors associated with resident distress and well-being have not been well described at a national level. To measure well-being in a national sample of internal medicine residents and to evaluate relationships with demographics, educational debt, and medical knowledge. Study of internal medicine residents using data collected on 2008 and 2009 Internal Medicine In-Training Examination (IM-ITE) scores and the 2008 IM-ITE survey. Participants were 16,394 residents, representing 74.1% of all eligible US internal medicine residents in the 2008-2009 academic year. This total included 7743 US medical graduates and 8571 international medical graduates. Quality of life (QOL) and symptoms of burnout were assessed, as were year of training, sex, medical school location, educational debt, and IM-ITE score reported as percentage of correct responses. Quality of life was rated "as bad as it can be" or "somewhat bad" by 2402 of 16,187 responding residents (14.8%). Overall burnout and high levels of emotional exhaustion and depersonalization were reported by 8343 of 16,192 (51.5%), 7394 of 16,154 (45.8%), and 4541 of 15,737 (28.9%) responding residents, respectively. In multivariable models, burnout was less common among international medical graduates than among US medical graduates (45.1% vs 58.7%; odds ratio, 0.70 [99% CI, 0.63-0.77]; P < .001). Greater educational debt was associated with the presence of at least 1 symptom of burnout (61.5% vs 43.7%; odds ratio, 1.72 [99% CI, 1.49-1.99]; P < .001 for debt >$200,000 relative to no debt). Residents reporting QOL "as bad as it can be" and emotional exhaustion symptoms daily had mean IM-ITE scores 2.7 points (99% CI, 1.2-4.3; P < .001) and 4.2 points (99% CI, 2.5-5.9; P < .001) lower than those with QOL "as good as it can be" and no emotional exhaustion symptoms, respectively. Residents reporting debt greater than $200,000 had mean IM-ITE scores 5.0 points (99% CI, 4.4-5.6; P < .001) lower than those with no debt. These differences were similar in magnitude to the 4.1-point (99% CI, 3.9-4.3) and 2.6-point (99% CI, 2.4-2.8) mean differences associated with progressing from first to second and second to third years of training, respectively. In this national study of internal medicine residents, suboptimal QOL and symptoms of burnout were common. Symptoms of burnout were associated with higher debt and were less frequent among international medical graduates. Low QOL, emotional exhaustion, and educational debt were associated with lower IM-ITE scores.
Chidagam, Prudhvi Raj Lakshmi Venkata; Gande, Vijaya Chandra; Yadlapalli, Sravanthi; Venkata, Ramani Yarlagadda; Kondaka, Sudheer; Chedalawada, Sravya
2017-04-01
Emergence of dental implants made the replacement of missing tooth easy. During the early days of introduction, implants were loaded three to six months after implant insertion, but understanding of healing cascade and improved production technology has changed the phase of restoration from delayed to immediate loading. To evaluate and compare the clinical outcome of immediate and delayed loaded implant supported prosthesis for missing mandibular first molar. The objectives were bleeding on probing, probing depth, implant mobility, marginal bone level and peri-implant radiolucency were evaluated during follow up period. Twenty patients were included in this study who were in the need of fixed implant supported prosthesis for missing mandibular first molar. Single tooth implant with immediate loading done within two days of implant insertion in one group and another group were loaded after three months of implant insertion. These groups were evaluated clinically and radiographically over a period of 72 months after loading using Wilcoxon matched pairs test and Mann-Whitney U test. The study consists of 14 male and six female patients with the age range of 19 to 31 years. There was no bleeding on probing and probing depth remained well within the normal range even after 72 months of loading among both the groups. Minimal marginal bone loss observed with no mobility and peri-implant radiolucency. Implant supported prosthesis for missing mandibular first molar with immediate loading can be used as a successful treatment modality. It reduces treatment time, provides early function and prevents undue migration of adjacent tooth. Immediate loading showed similar clinical and radiographic results as that of delayed loading, indicating it as an equally efficient technique for implant supported prosthesis.
NASA Astrophysics Data System (ADS)
Brunner, D.; Kuang, A. Q.; LaBombard, B.; Burke, W.
2017-07-01
A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enable self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. In addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.
Development and investigation of flexible polymer neural probe for chronic neural recording
NASA Astrophysics Data System (ADS)
Smith, Courtney; Song, Kyo D.; Yoon, Hargsoon; Kim, Woong-Ki; Zeng, Tao; Sanford, Larry D.
2012-04-01
Neural recording through microelectrodes requires biocompatibility and long term chronic usage. With a potential for various applications and effort to improve the performance of neural recording probes, consideration is taken to the tissue and cellular effects in these device designs. The degeneration of neurons due to brain tissue motion is an issue along with brain tissue inflammation in the insertion of the probes. To account for motion and irritation the material structure of the probes must be improved upon. This research presents the fabrication of neural probes on the microscale utilizing flexible polymers. Polyimide neural probes have been considered possibly to reduce degradation in their variability caused by brain motion. The microfabrication of the polyimide neural probe has an increased flexibility while accounting for biocompatibility and the needs for chronic use. Through microfabrication processes a needle probe is produced and tested for neural recording.
Interpretation of plasma impurity deposition probes. Analytic approximation
NASA Astrophysics Data System (ADS)
Stangeby, P. C.
1987-10-01
Insertion of a probe into the plasma induces a high speed flow of the hydrogenic plasma to the probe which, by friction, accelerates the impurity ions to velocities approaching the hydrogenic ion acoustic speed, i.e., higher than the impurity ion thermal speed. A simple analytic theory based on this effect provides a relation between impurity fluxes to the probe Γimp and the undisturbed impurity ion density nimp, with the hydrogenic temperature and density as input parameters. Probe size also influences the collection process and large probes are found to attract a higher flux density than small probes in the same plasma. The quantity actually measured, cimp, the impurity atom surface density (m-2) net-deposited on the probe, is related to Γimp and thus to nimp by taking into account the partial removal of deposited material caused by sputtering and the redeposition process.
Starter for inductively coupled plasma tube
Hull, D.E.; Bieniewski, T.M.
1988-08-23
A starter assembly is provided for use with an inductively coupled plasma (ICP) tube to reliably initiate a plasma at internal pressures above about 30 microns. A conductive probe is inserted within the inductor coil about the tube and insulated from the tube shield assembly. A capacitive circuit is arranged for momentarily connecting a high voltage radio-frequency generator to the probe while simultaneously energizing the coil. When the plasma is initiated the probe is disconnected from the generator and electrically connected to the shield assembly for operation. 1 fig.
Pioneer probe mission with orbiter option
NASA Technical Reports Server (NTRS)
1975-01-01
A spacecraft is described which is based on Pioneer 10 and 11, and existing propulsion technology; it can transport and release a probe for entry into Jupiter's atmosphere, and subsequently maneuver to place the spacecraft in orbit about Jupiter. Orbital operations last 3 years and include maneuvers to provide multiple close satellite encounters which allow the orbit to be significantly changed to explore different parts of the magnetosphere. A mission summary, a guide to related documents, and background information about Jupiter are presented along with mission analysis over the complete mission profile. Other topics discussed include the launch, interplanetary flight, probe release and orbit deflection, probe entry, orbit selection, orbit insertion, periapsis raising, spacecraft description, and the effects of Jupiter's radiation belt on both orbiter and the probe.
Effect of leg exercise training on vascular volumes during 30 days of 6 degrees head-down bed rest
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Vernikos, J.; Wade, C. E.; Barnes, P. R.
1992-01-01
Plasma and red cell volumes, body density, and water balance were measured in 19 men (32-42 yr) confined to bed rest (BR). One group (n = 5) had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise for 60 min/day (ITE; n = 7), and the third near-maximal intermittent isokinetic exercise for 60 min/day (IKE; n = 7). Caloric intake was 2,678-2,840 kcal/day; mean body weight (n = 19) decreased by 0.58 +/- 0.35 (SE) kg during BR due to a negative fluid balance (diuresis) on day 1. Mean energy costs for the NOE, and IKE, and ITE regimens were 83 (3.6 +/- 0.2 ml O2.min-1.kg-1), 214 (8.9 +/- 0.5 ml.min-1.kg-1), and 446 kcal/h (18.8 +/- 1.6 ml.min-1.kg-1), respectively. Body densities within groups and mean urine volumes (1,752-1,846 ml/day) between groups were unchanged during BR. Resting changes in plasma volume (ml/kg) after BR were -1.5 +/- 2.3% (NS) in ITE, -14.7 +/- 2.8% (P less than 0.05) in NOE, and -16.8 +/- 2.9% (P less than 0.05) in IKE, and mean water balances during BR were +295, -106, and +169 ml/24 h, respectively. Changes in red cell volume followed changes in plasma volume. The significant chronic decreases in plasma volume in the IKE and NOE groups and its maintenance in the ITE group could not be accounted for by water balance or by responses of the plasma osmotic, protein, vasopressin, or aldosterone concentrations or plasma renin activity. There was close coupling between resting plasma volume and plasma protein and osmotic content.(ABSTRACT TRUNCATED AT 250 WORDS).
Increased aryl hydrocarbon receptor expression in patients with allergic rhinitis.
Wei, P; Hu, G-H; Kang, H-Y; Yao, H-B; Kou, W; Liu, H; Hong, S-L
2014-02-01
A predominant Th17 population is a marker of allergic rhinitis (AR). As a ligand-activated transcription factor, the aryl hydrocarbon receptor (AhR) plays a vital role in promoting or inhibiting the development of specific Th cells. However, its role in AR remains undefined. To analyze the potential role of AhR in the pathogenesis of AR. In total, 30 AR patients and 13 healthy controls were recruited for this study and AR patients had clinical features, as demonstrated by rhinoconjunctivitis quality of life questionnaires, total symptom scores and visual analog scale scores. The expression of AhR, IL-17 and IL-22 and the presence of Th17 cells in peripheral blood mononuclear cells were measured before and after treatment with the nontoxic AhR ligand 2-(1'H-indole-3'-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE). Pretreatment ITE studies revealed that all AR patients had a significant increase in AhR expression compared with controls and AhR expression positively correlated with clinical parameters. After ITE intervention, a severe reduction in the differentiation of Th17 cells and the production of IL-17 and IL-22 was noted in both AR patients and normal subjects. Simultaneously, a dramatic enhancement of AhR expression was also observed in all healthy controls, but not in AR patients. The results suggested that the AhR may be one of the mechanisms underlying the Th17 response during the pathogenesis of AR and AhR levels were closely related to clinical severity in all AR patients. Additionally, ITE may represent a new drug candidate in the treatment of AR.
Casali, John G; Robinette, Martin B
2015-02-01
To determine if training with electronically-modulated hearing protection (EMHP) and the open ear results in auditory learning on a horizontal localization task. Baseline localization testing was conducted in three listening conditions (open-ear, in-the-ear (ITE) EMHP, and over-the-ear (OTE) EMHP). Participants then wore either an ITE or OTE EMHP for 12, almost daily, one-hour training sessions. After training was complete, participants again underwent localization testing in all three listening conditions. A computer with a custom software and hardware interface presented localization sounds and collected participant responses. Twelve participants were recruited from the student population at Virginia Tech. Audiometric requirements were 35 dBHL at 500, 1000, and 2000 Hz bilaterally, and 55 dBHL at 4000 Hz in at least one ear. Pre-training localization performance with an ITE or OTE EMHP was worse than open-ear performance. After training with any given listening condition, including open-ear, performance in that listening condition improved, in part from a practice effect. However, post-training localization performance showed near equal performance between the open-ear and training EMHP. Auditory learning occurred for the training EMHP, but not for the non-training EMHP; that is, there was no significant training crossover effect between the ITE and the OTE devices. It is evident from this study that auditory learning (improved horizontal localization performance) occurred with the EMHP for which training was performed. However, performance improvements found with the training EMHP were not realized in the non-training EMHP. Furthermore, localization performance in the open-ear condition also benefitted from training on the task.
Associations between quality indicators of internal medicine residency training programs
2011-01-01
Background Several residency program characteristics have been suggested as measures of program quality, but associations between these measures are unknown. We set out to determine associations between these potential measures of program quality. Methods Survey of internal medicine residency programs that shared an online ambulatory curriculum on hospital type, faculty size, number of trainees, proportion of international medical graduate (IMG) trainees, Internal Medicine In-Training Examination (IM-ITE) scores, three-year American Board of Internal Medicine Certifying Examination (ABIM-CE) first-try pass rates, Residency Review Committee-Internal Medicine (RRC-IM) certification length, program director clinical duties, and use of pharmaceutical funding to support education. Associations assessed using Chi-square, Spearman rank correlation, univariate and multivariable linear regression. Results Fifty one of 67 programs responded (response rate 76.1%), including 29 (56.9%) community teaching and 17 (33.3%) university hospitals, with a mean of 68 trainees and 101 faculty. Forty four percent of trainees were IMGs. The average post-graduate year (PGY)-2 IM-ITE raw score was 63.1, which was 66.8 for PGY3s. Average 3-year ABIM-CE pass rate was 95.8%; average RRC-IM certification was 4.3 years. ABIM-CE results, IM-ITE results, and length of RRC-IM certification were strongly associated with each other (p < 0.05). PGY3 IM-ITE scores were higher in programs with more IMGs and in programs that accepted pharmaceutical support (p < 0.05). RRC-IM certification was shorter in programs with higher numbers of IMGs. In multivariable analysis, a higher proportion of IMGs was associated with 1.17 years shorter RRC accreditation. Conclusions Associations between quality indicators are complex, but suggest that the presence of IMGs is associated with better performance on standardized tests but decreased duration of RRC-IM certification. PMID:21651768
Assessing the evolution of redundancy/synergy of spontaneous variability regulation with age.
Porta, Alberto; Bari, Vlasta; De Maria, Beatrice; Perseguini, Natália M; Milan, Juliana; Rehder-Santos, Patricia; Minatel, Vinícius; Takahashi, Anielle C M; Catai, Aparecida M
2017-05-01
We exploited a model-based Wiener-Granger causality method in the information domain for the evaluation of the transfer entropy (TE) and interaction TE (ITE), the latter taken as a measure of the net balance between redundancy and synergy, to describe the interactions between the spontaneous variability of heart period (HP) and systolic arterial pressure (SAP) and the effect of respiration (R) on both variables. Cardiac control was typified via the genuine TE from SAP to HP, that from R to HP, and the ITE from SAP and R to HP, while vascular control was characterized via the genuine TE from HP to SAP, that from R to SAP, and the ITE from HP and R to SAP. The approach was applied to study age-related modifications of cardiac and vascular controls in a cohort of 100 healthy humans (age from 21 to 70 years, 54 males) recorded at supine rest (REST) and during active standing (STAND). A surrogate approach was exploited to test the significance of the computed quantities. Trends of the genuine information transfer with age, already present in literature, were here confirmed. We originally found that: (i) at REST redundancy was predominant over synergy in both vascular and cardiac controls; (ii) the predominance of redundancy of the cardiac control was not affected by postural challenge, while STAND reduced redundancy of vascular control; (iii) the net redundancy of the cardiac control at REST gradually decreased with age, while that of vascular control remained stable; (iv) during STAND net redundancy of both cardiac and vascular controls was stable with age. The study confirms the relevance of computing genuine information transfer in cardiovascular control analysis and stresses the importance of evaluating the ITE to quantify the degree of redundancy of physiological mechanisms operating to maintain cardiovascular homeostasis.
Transvaginal ultrasound (image)
Transvaginal ultrasound is a method of imaging the genital tract in females. A hand held probe is inserted directly ... vaginal cavity to scan the pelvic structures, while ultrasound pictures are viewed on a monitor. The test ...
Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul
2016-05-01
A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.
An inverse method to estimate stem surface heat flux in wildland fires
Anthony S. Bova; Matthew B. Dickinson
2009-01-01
Models of wildland fire-induced stem heating and tissue necrosis require accurate estimates of inward heat flux at the bark surface. Thermocouple probes or heat flux sensors placed at a stem surface do not mimic the thermal response of tree bark to flames.We show that data from thin thermocouple probes inserted just below the bark can be used, by means of a one-...
Accurate multi-robot targeting for keyhole neurosurgery based on external sensor monitoring.
Comparetti, Mirko Daniele; Vaccarella, Alberto; Dyagilev, Ilya; Shoham, Moshe; Ferrigno, Giancarlo; De Momi, Elena
2012-05-01
Robotics has recently been introduced in surgery to improve intervention accuracy, to reduce invasiveness and to allow new surgical procedures. In this framework, the ROBOCAST system is an optically surveyed multi-robot chain aimed at enhancing the accuracy of surgical probe insertion during keyhole neurosurgery procedures. The system encompasses three robots, connected as a multiple kinematic chain (serial and parallel), totalling 13 degrees of freedom, and it is used to automatically align the probe onto a desired planned trajectory. The probe is then inserted in the brain, towards the planned target, by means of a haptic interface. This paper presents a new iterative targeting approach to be used in surgical robotic navigation, where the multi-robot chain is used to align the surgical probe to the planned pose, and an external sensor is used to decrease the alignment errors. The iterative targeting was tested in an operating room environment using a skull phantom, and the targets were selected on magnetic resonance images. The proposed targeting procedure allows about 0.3 mm to be obtained as the residual median Euclidean distance between the planned and the desired targets, thus satisfying the surgical accuracy requirements (1 mm), due to the resolution of the diffused medical images. The performances proved to be independent of the robot optical sensor calibration accuracy.
Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.
Lee, Chanyang; Woo, Henry H
2015-06-01
Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.
Flexible poly(methyl methacrylate)-based neural probe: An affordable implementation
NASA Astrophysics Data System (ADS)
Gasemi, Pejman; Veladi, Hadi; Shahabi, Parviz; Khalilzadeh, Emad
2018-03-01
This research presents a novel technique used to fabricate a deep brain stimulation probe based on a commercial poly(methyl methacrylate) (PMMA) polymer. This technique is developed to overcome the high cost of available probes crucial for chronic stimulation and recording in neural disorders such as Parkinson’s disease and epilepsy. The probe is made of PMMA and its mechanical properties have been customized by controlling the reaction conditions. The polymer is adjusted to be stiff enough to be easily inserted and, on the other hand, soft enough to perform required movements. As cost is one of the issues in the use of neural probes, a simple process is proposed for the production of PMMA neural probes without using expensive equipment and operations, and without compromising performance and quality. An in vivo animal test was conducted to observe the recording capability of a PMMA probe.
Table-driven image transformation engine algorithm
NASA Astrophysics Data System (ADS)
Shichman, Marc
1993-04-01
A high speed image transformation engine (ITE) was designed and a prototype built for use in a generic electronic light table and image perspective transformation application code. The ITE takes any linear transformation, breaks the transformation into two passes and resamples the image appropriately for each pass. The system performance is achieved by driving the engine with a set of look up tables computed at start up time for the calculation of pixel output contributions. Anti-aliasing is done automatically in the image resampling process. Operations such as multiplications and trigonometric functions are minimized. This algorithm can be used for texture mapping, image perspective transformation, electronic light table, and virtual reality.
Indirect tissue electrophoresis: a new method for analyzing solid tissue protein.
Smith, A C
1988-01-01
1. The eye lens core (nucleus) has been a valuable source of molecular biologic information. 2. In these studies, lens nuclei are usually homogenized so that any protein information related to anatomical subdivisions, or layers, of the nucleus is lost. 3. The present report is of a new method, indirect tissue electrophoresis (ITE), which, when applied to fish lens nuclei, permitted (a) automatic correlation of protein information with anatomic layer, (b) production of large, clear electrophoretic patterns even from small tissue samples and (c) detection of more proteins than in liquid extracts of homogenized tissues. 4. ITE seems potentially applicable to a variety of solid tissues.
The fast reciprocating magnetic probe system on the J-TEXT tokamak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Fuming; Chen, Zhipeng, E-mail: zpchen@hust.edu.cn; Zhuang, Ge
The fast reciprocating magnetic probe (FRMP) system is newly developed on the Joint Texas Experimental Tokamak (J-TEXT) to measure the local magnetic fluctuations at the plasma edge. The magnetic probe array in the FRMP consists of four 2-dimensional magnetic probes arranged at different radial locations to detect local poloidal and radial magnetic fields. These probes are protected by a graphite and boron nitride casing to improve the frequency response of each probe; they are mounted on the head of a movable rod, which is oriented along radial direction at the top of the torus. In the experiments, multiple core diagnosticsmore » show that the insertion of the FRMP has little impact on the equilibrium of the plasma. Local magnetic fluctuations inside the last closed flux surface are successfully measured by the FRMP.« less
Dyrlund, O; Bisgaard, N
1991-01-01
The properties of a prototype DFS (digital feedback suppression) system have been investigated. 21 ears fitted with behind-the-ear (BTE) hearing instruments and hard acrylic ear-moulds and 4 ears fitted with vented in-the-ear (ITE) hearing instruments were selected for the investigation. Two ITE instruments with different venting were employed to one of the ears. Complex loop gain has been measured in an anechoic room, and from these measurements the improvements in acoustic feedback margin due to the DFS system have been determined. For the BTE group, median values of 13.1 and 10.0 dB of improvement were established for two sets of measurements introducing a 180 degrees phase shift in connection with the last set of measurements. For the ITE group, values from 9.8 to 16.1 dB and from 13.7 to 16.3 dB of improvement were observed for the normal and the 180 degrees phase shift conditions respectively. Beyond this the DFS system may improve the sound quality to some extent, because the amplitude distortion, caused by the external feedback signal, is almost completely eliminated.
The dependability of medical students' performance ratings as documented on in-training evaluations.
van Barneveld, Christina
2005-03-01
To demonstrate an approach to obtain an unbiased estimate of the dependability of students' performance ratings during training, when the data-collection design includes nesting of student in rater, unbalanced nest sizes, and dependent observations. In 2003, two variance components analyses of in-training evaluation (ITE) report data were conducted using urGENOVA software. In the first analysis, the dependability for the nested and unbalanced data-collection design was calculated. In the second analysis, an approach using multiple generalizability studies was used to obtain an unbiased estimate of the student variance component, resulting in an unbiased estimate of dependability. Results suggested that there is bias in estimates of the dependability of students' performance on ITEs that are attributable to the data-collection design. When the bias was corrected, the results indicated that the dependability of ratings of student performance was almost zero. The combination of the multiple generalizability studies method and the use of specialized software provides an unbiased estimate of the dependability of ratings of student performance on ITE scores for data-collection designs that include nesting of student in rater, unbalanced nest sizes, and dependent observations.
Visual probes and methods for placing visual probes into subsurface areas
Clark, Don T.; Erickson, Eugene E.; Casper, William L.; Everett, David M.
2004-11-23
Visual probes and methods for placing visual probes into subsurface areas in either contaminated or non-contaminated sites are described. In one implementation, the method includes driving at least a portion of a visual probe into the ground using direct push, sonic drilling, or a combination of direct push and sonic drilling. Such is accomplished without providing an open pathway for contaminants or fugitive gases to reach the surface. According to one implementation, the invention includes an entry segment configured for insertion into the ground or through difficult materials (e.g., concrete, steel, asphalt, metals, or items associated with waste), at least one extension segment configured to selectively couple with the entry segment, at least one push rod, and a pressure cap. Additional implementations are contemplated.
Prifti, Efthymia; Reymond, Luc; Umebayashi, Miwa; Hovius, Ruud; Riezman, Howard; Johnsson, Kai
2014-03-21
A fluorogenic probe for plasma membrane proteins based on the dye Nile Red and SNAP-tag is introduced. It takes advantage of Nile Red, a solvatochromic molecule highly fluorescent in an apolar environment, such as cellular membranes, but almost dark in a polar aqueous environment. The probe possesses a tuned affinity for membranes allowing its Nile Red moiety to insert into the lipid bilayer of the plasma membrane, becoming fluorescent, only after its conjugation to a SNAP-tagged plasma membrane protein. The fluorogenic character of the probe was demonstrated for different SNAP-tag fusion proteins, including the human insulin receptor. This work introduces a new approach for generating a powerful turn-on probe for "no-wash" labeling of plasma membrane proteins with numerous applications in bioimaging.
Real time sensor for therapeutic radiation delivery
Bliss, M.; Craig, R.A.; Reeder, P.L.
1998-01-06
The invention is a real time sensor for therapeutic radiation. A probe is placed in or near the patient that senses in real time the dose at the location of the probe. The strength of the dose is determined by either an insertion or an exit probe. The location is determined by a series of vertical and horizontal sensing elements that gives the operator a real time read out dose location relative to placement of the patient. The increased accuracy prevents serious tissue damage to the patient by preventing overdose or delivery of a dose to a wrong location within the body. 14 figs.
Real time sensor for therapeutic radiation delivery
Bliss, Mary; Craig, Richard A.; Reeder, Paul L.
1998-01-01
The invention is a real time sensor for therapeutic radiation. A probe is placed in or near the patient that senses in real time the dose at the location of the probe. The strength of the dose is determined by either an insertion or an exit probe. The location is determined by a series of vertical and horizontal sensing elements that gives the operator a real time read out dose location relative to placement of the patient. The increased accuracy prevents serious tissue damage to the patient by preventing overdose or delivery of a dose to a wrong location within the body.
Probing and Tapping: Are We Inserting Pedicle Screws Correctly?
Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John
2016-11-01
Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be expected in the clinical scenario, however, it may not be the same as seen with the uniform density polyurethane foam tested in the current study. Copyright © 2016 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.
Berthier, Y; Thierry, D; Lemattre, M; Guesdon, J L
1994-01-01
A new insertion sequence was isolated from Xanthomonas campestris pv. dieffenbachiae. Sequence analysis showed that this element is 1,158 bp long and has 15-bp inverted repeat ends containing two mismatches. Comparison of this sequence with sequences in data bases revealed significant homology with Escherichia coli IS5. IS1051, which detected multiple restriction fragment length polymorphisms, was used as a probe to characterize strains from the pathovar dieffenbachiae. Images PMID:7906933
Kobayashi, Akira; Yokogawa, Hideaki; Yamazaki, Natsuko; Masaki, Toshinori; Sugiyama, Kazuhisa
2015-01-01
Purpose To report the first case of Descemet membrane endothelial keratoplasty (DMEK) for bullous keratopathy (BK) secondary to argon laser iridotomy (ALI). Patient A 71-year-old woman presented with decreased visual acuity in her right eye due to BK secondary to ALI that was performed 10 years prior. Results Phacosurgery was performed first, followed by successful DMEK 4 months later. A DMEK shooter was used for donor insertion, which allowed for a stable anterior chamber during donor insertion, even when the anterior chamber was quite shallow. Also, removal of edematous epithelial cells and endoillumination probe-assisted DMEK was quite useful to visualize DMEK graft on the background of the dark brown iris seen in Asian eyes. The patient’s best corrected visual acuity rapidly increased from 20/200 to 25/20 after 1 month, with complete resolution of corneal edema. Conclusion We reported the first successful DMEK case for BK secondary to ALI. The use of a DMEK shooter for donor insertion and endoillumination assistance to visualize the DMEK graft was a useful technique for BK secondary to ALI. PMID:25609910
Lens-free all-fiber probe with an optimized output beam for optical coherence tomography.
Ding, Zhihua; Qiu, Jianrong; Shen, Yi; Chen, Zhiyan; Bao, Wen
2017-07-15
A high-efficiency lensless all-fiber probe for optical coherence tomography (OCT) is presented. The probe is composed of a segment of large-core multimode fiber (MMF), a segment of tapered MMF, and a length of single-mode fiber (SMF). A controllable output beam can be designed by a simple adjustment of its probe structure parameters (PSPs), instead of the selection of fibers with different optical parameters. A side-view probe with a diameter of 340 μm and a rigid length of 6.37 mm was fabricated, which provides an effective imaging range of ∼0.6 mm with a full width at half-maximum beam diameter of less than 30 μm. The insertion loss of the probe was measured to be 0.81 dB, ensuring a high sensitivity of 102.25 dB. Satisfactory images were obtained by the probe-based OCT system, demonstrating the feasibility of the probe for endoscopic OCT applications.
Method for introducing unidirectional nested deletions
Dunn, John J.; Quesada, Mark A.; Randesi, Matthew
2001-01-01
Disclosed is a method for the introduction of unidirectional deletions in a cloned DNA segment in the context of a cloning vector which contains an f1 endonuclease recognition sequence adjacent to the insertion site of the DNA segment. Also disclosed is a method for producing single-stranded DNA probes utilizing the same cloning vector. An optimal vector, PZIP is described. Methods for introducing unidirectional deletions into a terminal location of a cloned DNA sequence which is inserted into the vector of the present invention are also disclosed. These methods are useful for introducing deletions into either or both ends of a cloned DNA insert, for high throughput sequencing of any DNA of interest.
Switalska, Angelika; Kierzek, Ryszard; Dembska, Anna; Juskowiak, Bernard
2017-12-01
The design, synthesis, and spectral properties of four pyrene labeled oligonucleotide probes with G-quadruplex structure (Tel22-Tpy, Tel22-Upy, Tel22-6Upy, Tel22-18Upy) based on the 22-mer human telomeric sequence (Tel22) have been reported. Pyrene labels in the form of ethynylpyrenyldeoxyuridine have been inserted efficiently into oligodeoxynucleotides probes using phosphoramidite chemistry. The probes exhibited abilities to fold into G-quadruplex structures and to bind metal cations (Na + and K + ). Folding properties of probes and their spectral behavior were examined by recording the UV-vis, fluorescence, and CD spectra as well as by analyzing melting profiles. Fluorescence characteristics and G-quadruplex folding of probes were also studied at the interface of cationic dioctadecyldimethylammonium bromide (DODAB) monolayer. Investigations included film balance measurements (π-A isotherms) and fluorescence spectra recording using a fiber optic accessory interfaced with a spectrofluorimeter. Copyright © 2017 Elsevier B.V. All rights reserved.
Method and system for fiber optic determination of gas concentrations in liquid receptacles
NASA Technical Reports Server (NTRS)
Nguyen, Quang-Viet (Inventor)
2008-01-01
A system for determining gas compositions includes a probe, inserted into a source of gaseous material, the probe having a gas permeable sensor tip and being capable of sending and receiving light to and from the gaseous material, a sensor body, connected to the probe, situated outside of the source and a fiber bundle, connected to the sensor body and communicating light to and from the probe. The system also includes a laser source, connected to one portion of the fiber bundle and providing laser light to the fiber bundle and the probe a Raman spectrograph, connected to another portion of the fiber bundle, receiving light from the probe and filtering the received light into specific channels and a data processing unit, receiving and analyzing the received light in the specific channels and outputting concentration of specific gas species in the gaseous material based on the analyzed received light.
High polarization purity operation of 99% in 9xx-nm broad stripe laser diodes
NASA Astrophysics Data System (ADS)
Morohashi, Rintaro; Yamagata, Yuji; Kaifuchi, Yoshikazu; Tada, Katsuhisa; Nogawa, Ryozaburo; Yamada, Yumi; Yamaguchi, Masayuki
2018-02-01
Polarization characteristics of self-aligned stripe (SAS) laser diodes (LDs) and Ridge-LDs are investigated to realize highly efficient polarization beam combined (PBC) LD modules. Vertical layers of both lasers are designed identically. Near field patterns (NFP) of TM polarization for the Ridge-LD showed peaks at the side edges, as expected by the strain simulation. On the other hand, SAS-LD showed a relatively flat and weak profile. Polarization purity (ITE/ (ITE+ITM)) of SAS-LDs exceeds 99%, while those of the Ridge-LDs are as low as 96%. It is confirmed that our SAS-LDs are suitable sources for PBC with low power loss.
Bioactive nitric oxide concentration does not increase during reactive hyperemia in human skin.
Zhao, J L; Pergola, P E; Roman, L J; Kellogg, D L
2004-02-01
This study examined whether nitric oxide (NO) is involved in the cutaneous response to reactive hyperemia (RH) in the human forearm. We enrolled seven healthy volunteers. NO concentrations were monitored using a NO selective amperometric electrode (ISO-NOP200, World Precision Instruments) inserted into the skin of the forearm. Laser-Doppler flowmetry (Moor Instruments) was used for monitoring skin blood flow (SkBF) at the same site. SkBF and NO levels were monitored and recorded continuously throughout the experiment. An intradermal microdialysis probe was inserted adjacent to the NO electrode for drug delivery. Data collection began 140 min after the NO electrodes and microdialysis probes were inserted. RH was achieved by the inflation of a blood pressure cuff to 25 mmHg above systolic pressure for 7 min after which the pressure in the cuff was abruptly released. Acetylcholine (ACh) was given by microdialysis probe at the end of RH study to verify the ability of the electrode system to detect changes in the NO concentration. SkBF and NO data before RH and immediately, 2, 5, 7, and 10 min after cuff deflation were used for analysis. SkBF increased immediately after release of the occlusion (P < 0.0001) and remained elevated for 2 min. No significant NO changes occurred with the increases in LDF. ACh induced increases in both SkBF and NO (P < 0.000 and P < 0.037, respectively). We conclude that RH increases SkBF by mechanisms that do not require a measurable increase in NO concentrations.
Physical mapping of complex genomes
Evans, Glen A.
1993-01-01
Method for simultaneous identification of overlapping cosmid clones among multiple cosmid clones and the use of the method for mapping complex genomes are provided. A library of cosmid clones that contains the DNA to be mapped is constructed and arranged in a manner such that individual clones can be identified and replicas of the arranged clones prepared. In preferred embodiments, the clones are arranged in a two dimensional matrix. In such embodiments, the cosmid clones in a row are pooled, mixed probes complementary to the ends of the DNA inserts int he pooled clones are synthesized, hybridized to a first replica of the library. Hybridizing clones, which include the pooled row, are identified. A second portion of clones is prepared by pooling cosmid clones that correspond to a column in the matrix. The second pool thereby includes one clone from the first portion pooled clones. This common clone is located on the replica at the intersection of the column and row. Mixed probes complementary to the ends of the DNA inserts in the second pooled portion of clones are prepared and hybridized to a second replica of the library. The hybridization pattern on the first and second replicas of the library are compared and cross-hybridizing clones, other than the clones in the pooled column and row, that hybridize to identical clones in the first and second replicas are identified. These clones necessarily include DNA inserts that overlap with the DNA insert int he common clone located at the intersection of the pooled row and pooled column. The DNA in the entire library may be mapped by pooling the clones in each of the rows and columns of the matrix, preparing mixed end-specific probes and hybridizing the probes from each row or column to a replica of the library. Since all clones in the library are located at the intersection of a column and a row, the overlapping clones for all clones in the library may be identified and a physical map constructed. In other preferred embodiments, the cosmid clones are arranged in a three dimensional matrix, pooled and compared in threes according to intersecting planes of the three dimensional matrix. Arrangements corresponding to geometries of higher dimensions may also be prepared and used to simultaneously identify overlapping clones in highly complex libraries with relatively few hybridization reactions.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Starr, J. C.; Van Beaumont, W.; Convertino, V. A.
1983-01-01
Measurements of maximal grip strength and endurance at 40 percent max strength were obtained for 7 men 19-21 years of age, 1-2 days before and on the first recovery day during three 2-week bedrest (BR) periods, each separated by a 3-week ambulatory recovery period. The subjects performed isometric exercise (IME) for 1 hr/day, isotonic exercise (ITE) for 1 hr/day, and no exercise (NOE) in the three BR periods. It was found that the mean maximal grip strength was unchanged after all three BR periods. Mean grip endurance was found to be unchanged after IME and ITE training, but was significantly reduced after NOE. These results indicate that IME and ITE training during BR do not increase or decrease maximal grip strength, alghough they prevent loss of grip endurance, while the maximal strength of all other major muscle groups decreases in proportion to the length of BR to 70 days. The maximal strength reduction of the large muscle groups was found to be about twice that of the small muscle groups during BR. In addition, it is shown that changes in maximal strength after spaceflight, BR, or water immersion deconditioning cannot be predicted from changes in submaximal or maximal oxygen uptake values.
A review on mechanical considerations for chronically-implanted neural probes
NASA Astrophysics Data System (ADS)
Lecomte, Aziliz; Descamps, Emeline; Bergaud, Christian
2018-06-01
This review intends to present a comprehensive analysis of the mechanical considerations for chronically-implanted neural probes. Failure of neural electrical recordings or stimulation over time has shown to arise from foreign body reaction and device material stability. It seems that devices that match most closely with the mechanical properties of the brain would be more likely to reduce the mechanical stress at the probe/tissue interface, thus improving body acceptance. The use of low Young’s modulus polymers instead of hard substrates is one way to enhance this mechanical mimetism, though compliance can be achieved through a variety of means. The reduction of probe width and thickness in comparison to a designated length, the use of soft hydrogel coatings and the release in device tethering to the skull, can also improve device compliance. Paradoxically, the more compliant the device, the more likely it will fail during the insertion process in the brain. Strategies have multiplied this past decade to offer partial or temporary stiffness to the device to overcome this buckling effect. A detailed description of the probe insertion mechanisms is provided to analyze potential sources of implantation failure and the need for a mechanically-enhancing structure. This leads us to present an overview of the strategies that have been put in place over the last ten years to overcome buckling issues. Particularly, great emphasis is put on bioresorbable polymers and their assessment for neural applications. Finally, a discussion is provided on some of the key features for the design of mechanically-reliable, polymer-based next generation of chronic neuroprosthetic devices.
2014-01-01
Background Selenite (SeO32−) oxyanion shows severe toxicity to biota. Different bacterial strains exist that are capable of reducing SeO32− to non-toxic elemental selenium (Se0), with the formation of Se nanoparticles (SeNPs). These SeNPs might be exploited for technological applications due to their physico-chemical and biological characteristics. The present paper discusses the reduction of selenite to SeNPs by a strain of Bacillus sp., SeITE01, isolated from the rhizosphere of the Se-hyperaccumulator legume Astragalus bisulcatus. Results Use of 16S rRNA and GyrB gene sequence analysis positioned SeITE01 phylogenetically close to B. mycoides. On agarized medium, this strain showed rhizoid growth whilst, in liquid cultures, it was capable of reducing 0.5 and 2.0 mM SeO32− within 12 and 24 hours, respectively. The resultant Se0 aggregated to form nanoparticles and the amount of Se0 measured was equivalent to the amount of selenium originally added as selenite to the growth medium. A delay of more than 24 hours was observed between the depletion of SeO32 and the detection of SeNPs. Nearly spherical-shaped SeNPs were mostly found in the extracellular environment whilst rarely in the cytoplasmic compartment. Size of SeNPs ranged from 50 to 400 nm in diameter, with dimensions greatly influenced by the incubation times. Different SeITE01 protein fractions were assayed for SeO32− reductase capability, revealing that enzymatic activity was mainly associated with the membrane fraction. Reduction of SeO32− was also detected in the supernatant of bacterial cultures upon NADH addition. Conclusions The selenite reducing bacterial strain SeITE01 was attributed to the species Bacillus mycoides on the basis of phenotypic and molecular traits. Under aerobic conditions, the formation of SeNPs were observed both extracellularly or intracellullarly. Possible mechanisms of Se0 precipitation and SeNPs assembly are suggested. SeO32− is proposed to be enzimatically reduced to Se0 through redox reactions by proteins released from bacterial cells. Sulfhydryl groups on peptides excreted outside the cells may also react directly with selenite. Furthermore, membrane reductases and the intracellular synthesis of low molecular weight thiols such as bacillithiols may also play a role in SeO32− reduction. Formation of SeNPs seems to be the result of an Ostwald ripening mechanism. PMID:24606965
NASA Astrophysics Data System (ADS)
Brandon, A. D.; Debaille, V.
2014-12-01
The 146Sm-142Nd (t1/2=68 Ma) chronometer can be used to examine silicate differentiation in the first 400 Ma of Earth history. Early fractionation between Sm and Nd is recorded in cratonic Archean rocks in their 142Nd/144Nd ratios that that deviate up to ±20 ppm, or μ142Nd - ppm deviation relative to the present-day convecting mantle at 0. These values likely record early extraction of incompatible trace element (ITE) enriched material with -μ142Nd, either as crust or late stage residual melt from a magma ocean, and resulting in a complimentary ITE depleted residual mantle with +μ142Nd. If this early-formed ITE-enriched material was re-incorporated rapidly back into the convecting mantle, both ITE-enriched and ITE-depleted mantle domains would have been established in the Hadean. Alternatively, if it was early-formed crust that remained stable it could have slowly eroded and progressively remixed into the convecting mantle as subducted sediment during the Archean. Each of these scenarios could potentially explain the decrease in the maximum variation in µ142Nd from ±20 at 4.0 Ga to 0 at 2.5 Ga [1,2,3]. In the scenario where these variations reflect mixing of mantle domains, this implies long mantle mixing times of greater than 1 Ga in the Archean in order to preserve the early-formed heterogeneities. This can be achieved in a stagnant lid tectonic regime in the Archean with sporadic and short subduction cycles [2]. This scenario would also indicate that mixing times in the convecting mantle were much slower than the previously proposed 100 Ma in the Hadean and Archean. In the alternative scenario, sediment with -µ142Nd was progressively mixed into the mantle via subduction in the Archean [3]. This scenario doesn't require slow mantle mixing times or a stagnant-lid regime. It requires crustal resident times of up to 750 Ma to maintain a steady supply of ancient sediment recycling over the Archean. Each of these scenarios evoke very contrasting conditions for early Earth history and additional examination is needed. We will consider the geochemical consequences of crustal sediment subduction in order to test the hypothesis of crustal recycling as well as provide additional evidence to aid in resolving this issue. [1] Bennett et al., Science, 318 (2007), p.1907 [2] Debaille et al., EPSL, 373 (2013), p.83 [3] Roth et al., G3, 2014
Moore, Desmond A.; Whatley, Zakiya N.; Joshi, Chandra P.; Osawa, Masaki
2016-01-01
ABSTRACT FtsZ, a bacterial tubulin homologue, is a cytoskeletal protein that assembles into protofilaments that are one subunit thick. These protofilaments assemble further to form a “Z ring” at the center of prokaryotic cells. The Z ring generates a constriction force on the inner membrane and also serves as a scaffold to recruit cell wall remodeling proteins for complete cell division in vivo. One model of the Z ring proposes that protofilaments associate via lateral bonds to form ribbons; however, lateral bonds are still only hypothetical. To explore potential lateral bonding sites, we probed the surface of Escherichia coli FtsZ by inserting either small peptides or whole fluorescent proteins (FPs). Among the four lateral surfaces on FtsZ protofilaments, we obtained inserts on the front and back surfaces that were functional for cell division. We concluded that these faces are not sites of essential interactions. Inserts at two sites, G124 and R174, located on the left and right surfaces, completely blocked function, and these sites were identified as possible sites for essential lateral interactions. However, the insert at R174 did not interfere with association of protofilaments into sheets and bundles in vitro. Another goal was to find a location within FtsZ that supported insertion of FP reporter proteins while allowing the FtsZ-FPs to function as the sole source of FtsZ. We discovered one internal site, G55-Q56, where several different FPs could be inserted without impairing function. These FtsZ-FPs may provide advances for imaging Z-ring structure by superresolution techniques. IMPORTANCE One model for the Z-ring structure proposes that protofilaments are assembled into ribbons by lateral bonds between FtsZ subunits. Our study excluded the involvement of the front and back faces of the protofilament in essential interactions in vivo but pointed to two potential lateral bond sites, on the right and left sides. We also identified an FtsZ loop where various fluorescent proteins could be inserted without blocking function; these FtsZ-FPs functioned as the sole source of FtsZ. This advance provides improved tools for all fluorescence imaging of the Z ring and may be especially important for superresolution imaging. PMID:27795325
Mallabaeva, D Sh; Ignatov, A N; Sheĭko, I A; Isikov, V P; Geliuta, V P; Boĭko, N G; Seriapin, A A; Dorokhov, D B
2007-01-01
Wild wheat Triticum boeoticum Boiss. is the rare species are included in the Red Book of Ukraine. This species are reducing the magnitude of population and the area of distribution under anthropogenic activity. We studied genetic structure of two populations of T. boeoticum, located on Sapun Mountain and in Baidar Valley in Crimea. According RAPD and ITE molecular analysis we have estimated that the population of T. boeoticum on Sapun Mountain is genetically more impoverished than a population from the Baidar Valley. For preservation of maximal natural genetic polymorphism of the rare species it is recommended to direct efforts to preservations of a population of T. boeoticum from the Baidar Valley.
NASA Astrophysics Data System (ADS)
Jung, C. C.; Stumpe, J.
2005-02-01
The new method of immersion transmission ellipsometry (ITE) [1] has been developed. It allows the highly accurate determination of the absolute three-dimensional (3D) refractive indices of anisotropic thin films. The method is combined with conventional ellipsometry in transmission and reflection, and the thickness determination of anisotropic films solely by optical methods also becomes more accurate. The method is applied to the determination of the 3D refractive indices of thin spin-coated films of an azobenzene-containing liquid-crystalline copolymer. The development of the anisotropy in these films by photo-orientation and subsequent annealing is demonstrated. Depending on the annealing temperature, oblate or prolate orders are generated.
i-TED: A novel concept for high-sensitivity (n,γ) cross-section measurements
NASA Astrophysics Data System (ADS)
Domingo-Pardo, C.
2016-07-01
A new method for measuring (n , γ) cross-sections aiming at enhanced signal-to-background ratio is presented. This new approach is based on the combination of the pulse-height weighting technique with a total energy detection system that features γ-ray imaging capability (i-TED). The latter allows one to exploit Compton imaging techniques to discriminate between true capture γ-rays arising from the sample under study and background γ-rays coming from contaminant neutron (prompt or delayed) captures in the surrounding environment. A general proof-of-concept detection system for this application is presented in this paper together with a description of the imaging method and a conceptual demonstration based on Monte Carlo simulations.
System design of the Pioneer Venus spacecraft. Volume 11: Launch vehicle utilization
NASA Technical Reports Server (NTRS)
Varga, R. J.
1973-01-01
A summary of the spacecraft descriptions; the probe bus, large probe, small probe, and orbiter is presented. The highlights on the designs of the Atlas/Centaur spacecraft as compared to the corresponding Thor/Delta spacecraft designs are contained. A comparison is made of the two Atlas/Centaur spacecraft for reference. The major differences are the replacement of the probes of the forward end of the probe bus with the mechanically despun antenna of the orbiter and the replacement of the bicone antenna on the aft end with the orbit insertion motor. The cross sections of the large and small probes are compared. The major features of each probe are described. The Thor/Delta and Atlas/Centaur designs for the probe bus and orbiter are analyzed. The usable spacecraft mass for the Atlas/Centaur is roughly twice that for the Thor/Delta if the Type I trajectory is assumed. It is somewhat less for the Type II trajectory in the designated launch years. This additional mass capability leads to cost savings in many areas which are described.
NASA Astrophysics Data System (ADS)
Sierakowski, Andrzej; Kopiec, Daniel; Majstrzyk, Wojciech; Kunicki, Piotr; Janus, Paweł; Dobrowolski, Rafał; Grabiec, Piotr; Rangelow, Ivo W.; Gotszalk, Teodor
2017-03-01
In this paper the authors compare methods used for piezoresistive microcantilevers actuation for the atomic force microscopy (AFM) imaging in the dynamic shear force mode. The piezoresistive detection is an attractive technique comparing the optical beam detection of deflection. The principal advantage is that no external alignment of optical source and detector are needed. When the microcantilever is deflected, the stress is transferred into a change of resistivity of piezoresistors. The integration of piezoresistive read-out provides a promising solution in realizing a compact non-contact AFM. Resolution of piezoresistive read-out is limited by three main noise sources: Johnson, 1/f and thermomechanical noise. In the dynamic shear force mode measurement the method used for cantilever actuation will also affect the recorded noise in the piezoresistive detection circuit. This is the result of a crosstalk between an aluminium path (current loop used for actuation) and piezoresistors located near the base of the beam. In this paper authors described an elaborated in ITE (Institute of Electron Technology) technology of fabrication cantilevers with piezoresistive detection of deflection and compared efficiency of two methods used for cantilever actuation.
A microfluidic brain slice perfusion chamber for multisite recording using penetrating electrodes.
Blake, Alexander J; Rodgers, Frank C; Bassuener, Anna; Hippensteel, Joseph A; Pearce, Thomas M; Pearce, Timothy R; Zarnowska, Ewa D; Pearce, Robert A; Williams, Justin C
2010-05-30
To analyze the spatiotemporal dynamics of network activity in a brain tissue slice, it is useful to record simultaneously from multiple locations. When obtained from laminar structures such as the hippocampus or neocortex, multisite recordings also yield information about subcellular current distributions via current source density analysis. Multisite probes developed for in vivo recordings could serve these purposes in vitro, allowing recordings to be obtained from brain slices at sites deeper within the tissue than currently available surface recording methods permit. However, existing recording chambers do not allow for the insertion of lamina-spanning probes that enter through the edges of brain slices. Here, we present a novel brain slice recording chamber design that accomplishes this goal. The device provides a stable microfluidic perfusion environment in which tissue health is optimized by superfusing both surfaces of the slice. Multichannel electrodes can be inserted parallel to the surface of the slice, at any depth relative to the surface. Access is also provided from above for the insertion of additional recording or stimulating electrodes. We illustrate the utility of this recording configuration by measuring current sources and sinks during theta burst stimuli that lead to the induction of long-term potentiation in hippocampal slices. (c) 2010 Elsevier B.V. All rights reserved.
Wen, Wei; Hu, Rong; Bao, Ting; Zhang, Xiuhua; Wang, Shengfu
2015-09-15
In this work, a sensitive exonuclease-assisted amplification electrochemical aptasensor through insertion approach was developed for the detection of mucin 1 (MUC 1). In order to construct the aptasensor, 6-Mercapto-1-hexanol (MCH) was used to block partial sites of gold electrode (GE), followed by thiolated capture probe self-assembled on GE. Methylene blue (MB) labeled aptamer hybridized with capture probe at both ends to form double-strand DNA. For the MB labeled termini was close to GE, the electrochemical response was remarkable. The presence of MUC 1 caused the dissociation of the double-strand DNA owing to the specific recognition of aptamer to MUC 1. Then exonuclease I (Exo I) selectively digested the aptamer which bound with MUC 1, the released MUC 1 participated new binding with the rest aptamer. Insertion approach improved the reproducibility and Exo I-catalyzed target recycling improved the sensitivity of the aptasensor significantly. Under optimal experimental conditions, the proposed aptasensor had a good linear correlation ranged from 10 pM to 1 μM with a detection limit of 4 pM (Signal to Noise ratio, S/N=3). The strategy had great potential for the simple and sensitive detection of other cancer markers. Copyright © 2015 Elsevier B.V. All rights reserved.
Damping insert materials for settling chambers of supersonic wind tunnels
NASA Astrophysics Data System (ADS)
Wu, Jie; Radespiel, Rolf
2017-03-01
This study describes the application of a novel damping insert material for reducing the flow fluctuations in a tandem nozzle supersonic wind tunnel. This new damping material is composed of multi-layer stainless steel wired meshes. The influences of the multi-layer mesh, such as the quantity of the mesh layer and the installed location in the settling chamber, to the freestream quality have been investigated. A Pitot probe instrumented with a Kulite pressure sensor and a hot-wire probe are employed to monitor the flow fluctuation in the test section of the wind tunnel. Thereafter, a combined modal analysis is applied for the disturbance qualification. Additionally, the transient Mach number in the test section is measured. The disturbance qualification indicates that the multi-layer mesh performs well in providing reduction of vorticity reduction and acoustic fluctuations. Comparable flow quality of the freestream was also obtained using a combination of flexible damping materials. However, the life-span of the new damping materials is much longer. The time transient of the Mach number measured in the test section indicates that the mean flow is rather constant over run time. Furthermore, the time-averaged pressure along the settling chamber is recorded and it shows the distribution of pressure drop by settling chamber inserts.
Apparatus and method of capturing an orbiting spacecraft
NASA Technical Reports Server (NTRS)
Harwell, William D. (Inventor); Gardner, Dale A. (Inventor)
1987-01-01
Apparatus and a method of capturing an orbiting spacecraft by attaching a grapple fixture are discussed. A probe is inserted into an opening, such as a rocket nozzle, in the spacecraft until a stop on the prove mechanism contacts the spacecraft. A lever is actuated releasing a spring loaded rod which moves axially along the probe removing a covering sleeve to expose spring loaded toffle fingers which pivot open engaging the side of the opening. The probe is shortened and tensioned by turning a screw thread, pressing the fingers inside of the opening to compress the spacecraft between the toggle fingers and the stop. A grapple fixture attached to the probe, which is thus secured to the spacecraft, is engaged by appropriate retrieval means such as a remote manipulator arm.
NASA Astrophysics Data System (ADS)
Viator, John A.; Paltauf, Guenther; Jacques, Steven L.; Prahl, Scott A.
2001-06-01
An endoscopic photoacoustic probe is designed and tested for use in PDT treatment of esophageal cancer. The probe, measuring less than 2.5 mm in diameter, was designed to fit within the lumen of an endoscope that will be inserted into an esophagus after PDT. PDT treatment results in a blanched, necrotic layer of cancerous tissue over a healthy, deeper layer of perfused tissue. The photoacoustic probe was designed to use acoustic propagation time to determine the thickness of the blanched surface of the esophagus, which corresponds to treatment depth. A side-firing 600 micrometers fiber delivered 532 nm laser light to induce acoustic waves in the perfused layer of the esophagus beneath the blanched (treated) layer. A PVDF transducer detected the induced acoustic waves and transmitted the signal to an oscilloscope. The probe was tested on clear and turbid tissue phantom layers over an optically absorbing dye solution.
Nanoneedle insertion into the cell nucleus does not induce double-strand breaks in chromosomal DNA.
Ryu, Seunghwan; Kawamura, Ryuzo; Naka, Ryohei; Silberberg, Yaron R; Nakamura, Noriyuki; Nakamura, Chikashi
2013-09-01
An atomic force microscope probe can be formed into an ultra-sharp cylindrical shape (a nanoneedle) using micro-fabrication techniques such as focused ion beam etching. This nanoneedle can be effectively inserted through the plasma membrane of a living cell to not only access the cytosol, but also to penetrate through the nuclear membrane. This technique shows great potential as a tool for performing intranuclear measurements and manipulations. Repeated insertions of a nanoneedle into a live cell were previously shown not to affect cell viability. However, the effect of nanoneedle insertion on the nucleus and nuclear components is still unknown. DNA is the most crucial component of the nucleus for proper cell function and may be physically damaged by a nanoneedle. To investigate the integrity of DNA following nanoneedle insertion, the occurrence of DNA double-strand breaks (DSBs) was assessed. The results showed that there was no chromosomal DNA damage due to nanoneedle insertion into the nucleus, as indicated by the expression level of γ-H2AX, a molecular marker of DSBs. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Haroon, Naveed; Ather, M Hammad; Khan, Salma; Kumar, Pirkash; Salam, Basit
2015-10-01
To compare preprocedure Diclofenac suppository and Xylocaine gel with Xylocaine gel only in patients undergoing transrectal ultrasound (TRUS)-guided biopsy of prostate for pain. It is a randomized controlled trial conducted on patients undergoing TRUS-guided biopsy for clinical or biochemical suspicion of prostate cancer following a written informed consent and Ethics Review Committee approval. Patients were randomized into 2 groups. Group A included those patients who received Diclofenac suppository 2 hours before in combination with 10 mL of 2% Xylocaine gel 5 minutes before biopsy. Group B received Xylocaine gel only. A visual analog scale was used to measure the pain scores at the time of TRUS probe insertion, just after taking biopsy cores and 2 hours after biopsy. A total of 100 patients were recruited in the study with 50 patients each in group A and B. Mean age of group A was 69.1 ± 10 years and 67.3 ± 8.1 years for group B. The mean pain score for group A and B at the time of probe insertion was 0.08 ± 0.27 and 0.34 ± 0.63 (P = .032), immediately after taking biopsy cores was 1.46 ± 1.15 and 4.68 ± 0.77 (P = .000), and 2 hours after biopsy was 0.14 ± 0.45 vs 2.40 ± 0.81 (P = .000), respectively. The mean pain score at the time of TRUS probe insertion, immediately after taking biopsy cores, and 2 hours after biopsy is statistically significantly higher in group B. Copyright © 2015 Elsevier Inc. All rights reserved.
Paradh, A D; Hill, A E; Mitchell, W J
2014-01-01
DNA probes specific for rRNA of selected target species were utilised for the detection of beer spoilage bacteria of the genera Pectinatus and Megasphaera using a hybridisation protection assay (HPA). All the probes were modified during synthesis by addition of an amino linker arm at the 5' end or were internally modified by inserting an amine modified thymidine base. Synthesised probes then were labelled with acridinium ester (AE) and purified using reverse phase HPLC. The internally AE labelled probes were able to detect target RNA within the range of 0.016-0.0032pmol. All the designed probes showed high specificity towards target RNA and could detect bacterial contamination within the range of ca. 5×10(2)1×10(3) CFU using the HPA. The developed assay was also compatible with MRS, NBB and SMMP beer enrichment media, routinely used in brewing laboratories. © 2013 Elsevier B.V. All rights reserved.
Electrical capacitance clearanceometer
NASA Technical Reports Server (NTRS)
Hester, Norbert J. (Inventor); Hornbeck, Charles E. (Inventor); Young, Joseph C. (Inventor)
1992-01-01
A hot gas turbine engine capacitive probe clearanceometer is employed to measure the clearance gap or distance between blade tips on a rotor wheel and its confining casing under operating conditions. A braze sealed tip of the probe carries a capacitor electrode which is electrically connected to an electrical inductor within the probe which is inserted into a turbine casing to position its electrode at the inner surface of the casing. Electrical power is supplied through a voltage controlled variable frequency oscillator having a tuned circuit in which the probe is a component. The oscillator signal is modulated by a change in electrical capacitance between the probe electrode and a passing blade tip surface while an automatic feedback correction circuit corrects oscillator signal drift. A change in distance between a blade tip and the probe electrode is a change in capacitance therebetween which frequency modulates the oscillator signal. The modulated oscillator signal which is then processed through a phase detector and related circuitry to provide an electrical signal is proportional to the clearance gap.
NcoI and TaqI RFLPs for human M creatine kinase (CKM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perryman, M.B.; Hejtmancik, J.F.; Ashizawa, Tetsuo
1988-09-12
Probe pHMCKUT contains a 135 bp cDNA fragment inserted into pGEM 3. The probe corresponds to nucleotides 1,201 to 1,336 located in the 3{prime} untranslated region of human M creatine kinase. The probe is specific for human M creatine kinase and does not hybridize to human B cretine kinase sequences. NcoI identifies a two allele polymorphism of a band at either 2.5 kb or 3.6 kb. TaqI identifies a two allele polymorphism at either 3.8 kb or 4.5 kb. Human M creatine has been localized to chromosome 19q. Autosomal co-dominant inheritance was shown in six informative Caucasian families.
Exercise Training During Bed Rest Attenuates Deconditioning
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Hargens, Alan R. (Technical Monitor)
1995-01-01
A 30-day 6 deg. head-down bed rest study was conducted to evaluate high-intensity, short-duration, alternating isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent isokinetic exercise (IKE) training regiments designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (acclimation) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volume, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (a) attenuated the decrease in peak VO2 by 50%, (b) attenuated loss of red cell volume by 40%, but had no effect on loss of plasma volume, (c) induced positive body water balance, (d) had no adverse effect on quality of sleep or concentration, and (e) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regiments, and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.
Directional hearing aid using hybrid adaptive beamformer (HAB) and binaural ITE array
NASA Astrophysics Data System (ADS)
Shaw, Scott T.; Larow, Andy J.; Gibian, Gary L.; Sherlock, Laguinn P.; Schulein, Robert
2002-05-01
A directional hearing aid algorithm called the Hybrid Adaptive Beamformer (HAB), developed for NIH/NIA, can be applied to many different microphone array configurations. In this project the HAB algorithm was applied to a new array employing in-the-ear microphones at each ear (HAB-ITE), to see if previous HAB performance could be achieved with a more cosmetically acceptable package. With diotic output, the average benefit in threshold SNR was 10.9 dB for three HoH and 11.7 dB for five normal-hearing subjects. These results are slightly better than previous results of equivalent tests with a 3-in. array. With an innovative binaural fitting, a small benefit beyond that provided by diotic adaptive beamforming was observed: 12.5 dB for HoH and 13.3 dB for normal-hearing subjects, a 1.6 dB improvement over the diotic presentation. Subjectively, the binaural fitting preserved binaural hearing abilities, giving the user a sense of space, and providing left-right localization. Thus the goal of creating an adaptive beamformer that simultaneously provides excellent noise reduction and binaural hearing was achieved. Further work remains before the HAB-ITE can be incorporated into a real product, optimizing binaural adaptive beamforming, and integrating the concept with other technologies to produce a viable product prototype. [Work supported by NIH/NIDCD.
Boule, Lisbeth A; Burke, Catherine G; Jin, Guang-Bi; Lawrence, B Paige
2018-01-29
The aryl hydrocarbon receptor (AHR) offers a compelling target to modulate the immune system. AHR agonists alter adaptive immune responses, but the consequences differ across studies. We report here the comparison of four agents representing different sources of AHR ligands in mice infected with influenza A virus (IAV): TCDD, prototype exogenous AHR agonist; PCB126, pollutant with documented human exposure; ITE, novel pharmaceutical; and FICZ, degradation product of tryptophan. All four compounds diminished virus-specific IgM levels and increased the proportion of regulatory T cells. TCDD, PCB126 and ITE, but not FICZ, reduced virus-specific IgG levels and CD8 + T cell responses. Similarly, ITE, PCB126, and TCDD reduced Th1 and Tfh cells, whereas FICZ increased their frequency. In Cyp1a1-deficient mice, all compounds, including FICZ, reduced the response to IAV. Conditional Ahr knockout mice revealed that all four compounds require AHR within hematopoietic cells. Thus, differences in the immune response to IAV likely reflect variances in quality, magnitude, and duration of AHR signaling. This indicates that binding affinity and metabolism may be stronger predictors of immune effects than a compound's source of origin, and that harnessing AHR will require finding a balance between dampening immune-mediated pathologies and maintaining sufficient host defenses against infection.
Development of a new mini-invasive tumour hyperthermia probe using high-temperature water vapour.
Yu, Tian-Hua; Zhou, Yi-Xin; Liu, Jing
2004-01-01
A new mini-invasive hyperthermia probe using high-temperature water vapour for deep regional tumour treatment was developed in this paper. The vacuum insulation mechanism was incorporated into the probe to avoid heating damage to the normal tissues around the edge of the insertion path. To better understand the heat transfer behaviour in living tissues due to operation of the probe, theoretical models based on the Pennes' equation were established and two closed form analytical solutions under constant flux or temperature heating at the tip of probe were obtained. Parametric studies were performed to investigate the influence of various parameters on the temperature response of tissues heated by the probe. Further, several simulating experiments on the actual heating performance of the probe fabricated in this paper were conducted on the in vitro biological materials (fresh pork) and phantom gel. It was demonstrated that the probe can cause a high enough temperature over the treatment area to thermally destroy the tumour tissue in due time, while the temperature over the surrounding healthy tissues can be kept below a safe threshold value. This mini-invasive heating probe may have significant applications in future clinical tumour hyperthermia.
NASA Astrophysics Data System (ADS)
Tait, A. W.; Schröder, C.; Ashley, J. W.; Velbel, M. A.; Boston, P. J.; Carrier, B. L.; Cohen, B. A.; Bland, P. A.
2018-04-01
We summarize insights about Mars gained from investigating meteorites found on Mars. Certain types of meteorites can be considered standard probes inserted into the martian environment. Should they be considered for Mars Sample Return?
Noise elimination method using a transmission line for the diagnostics of radio frequency plasma
NASA Astrophysics Data System (ADS)
Shimizu, K.; Hallil, A.; Amemiya, H.
1997-04-01
A filter using a transmission line formed by a cascade connection of inverted L-type networks has been developed to reject the distortion of the probe characteristics by rf (radio-frequency) noise. Each inverse L network consists of two coaxial cables with the same physical constant and length. The filter can remove discrete frequency components including the fundamental and harmonic components, the cut-off frequencies being determined by the distributed circuit constant and the length of the cables. By inserting different kinds of the network in cascade, many noise components associated with the rf frequency can be eliminated at the end section of the filter. Experiments have been performed in rf plasmas by inserting three kinds of inverted L networks with the frequency f (13.56 MHz), 2 f and 4f as the cut-off frequency. Distortion free probe characteristics have been obtained, from which accurate determination of plasma parameter such as the electron energy distribution is possible.
Durable fiber optic sensor for gas temperature measurement in the hot section of turbine engines
NASA Astrophysics Data System (ADS)
Tregay, George W.; Calabrese, Paul R.; Finney, Mark J.; Stukey, K. B.
1994-10-01
An optical sensor system extends gas temperature measurement capability in turbine engines beyond the present generation of thermocouple technology. The sensing element which consists of a thermally emissive insert embedded inside a sapphire lightguide is capable of operating above the melting point of nickel-based super alloys. The emissive insert generates an optical signal as a function of temperature. Continued development has led to an optically averaged system by combining the optical signals from four individual sensing elements at a single detector assembly. The size of the signal processor module has been reduced to overall dimensions of 2 X 4 X 0.7 inches. The durability of the optical probe design has been evaluated in an electric-utility operated gas turbine under the sponsorship of the Electric Power Research Institute. The temperature probe was installed between the first stage rotor and second stage nozzle on a General Electric MS7001B turbine. The combined length of the ceramic support tube and sensing element reached 1.5 inches into the hot gas stream. A total of over 2000 hours has been accumulated at probe operation temperatures near 1600 degree(s)F. An optically averaged sensor system was designed to replace the existing four thermocouple probes on the upper half of a GE F404 aircraft turbine engine. The system was ground tested for 250 hours as part of GE Aircraft Engines IR&D Optical Engine Program. Subsequently, two flight sensor systems were shipped for use on the FOCSI (Fiber Optic Control System Integration) Program. The optical harnesses, each with four optical probes, measure the exhaust gas temperature in a GE F404 engine.
Issues in Urban Trip Generation
DOT National Transportation Integrated Search
2017-08-01
In 1976, the Institute of Transportation Engineers (ITE) compiled their first Handbook of guidelines and methods for evaluating developmentlevel transportation impacts, specifically vehicular impacts (Institute of Transportation Engineers 1976). Deca...
Method for reducing measurement errors of a Langmuir probe with a protective RF shield
NASA Astrophysics Data System (ADS)
Riaby, V.; Masherov, P.; Savinov, V.; Yakunin, V.
2018-04-01
Probe measurements were conducted in the middle cross-section of an inductive, low-pressure xenon plasma using a straight cylindrical Langmuir probe with a bare metal shield that protected the probe from radio frequency interference. As a result, reliable radial distributions of the plasma parameters were obtained. Subsequent analyses of these measurements revealed that the electron energy distribution function (EEDF) deviated substantially from the Maxwellian functions and that this deviation depended on the length of the probe shield. To evaluate the shield's influence on the measurement results, in addition to the probe (which was moved radially as its shield length varied in the range of lsh1 = lmax-0), an additional L-shaped probe was inserted at a different location. This probe was moved differently from the first probe and provided confirmational measurements in the common special position where lsh1 = 0 and lsh2 ≠ 0. In this position, the second shield decreased all the plasma parameters. A comparison of the probe datasets identified the principles of the relationships between measurement errors and EEDF distortions caused by the bare probe shields. This dependence was used to correct the measurements performed using the first probe by eliminating the influence of its shield. Physical analyses based on earlier studies showed that these peculiarities are caused by a short-circuited double-probe effect that occurs in bare metal probe protective shields.
Text Mining of UU-ITE Implementation in Indonesia
NASA Astrophysics Data System (ADS)
Hakim, Lukmanul; Kusumasari, Tien F.; Lubis, Muharman
2018-04-01
At present, social media and networks act as one of the main platforms for sharing information, idea, thought and opinions. Many people share their knowledge and express their views on the specific topics or current hot issues that interest them. The social media texts have rich information about the complaints, comments, recommendation and suggestion as the automatic reaction or respond to government initiative or policy in order to overcome certain issues.This study examines the sentiment from netizensas part of citizen who has vocal sound about the implementation of UU ITE as the first cyberlaw in Indonesia as a means to identify the current tendency of citizen perception. To perform text mining techniques, this study used Twitter Rest API while R programming was utilized for the purpose of classification analysis based on hierarchical cluster.
Prospects for searching the η→e+e- rare decay at the CSR
NASA Astrophysics Data System (ADS)
Ji, Chang-Sheng; Shao, Ming; Zhang, Hui; Chen, Hong-Fang; Zhang, Yi-Fei
2013-04-01
We study the possibility of searching the η→e+e- rare decay on the Cooling Storage Ring (CSR) at Lanzhou. The main features of the proposed Internal Target Experiment (ITE) and External Target Facility (ETF) are included in the Monte Carlo simulation. Both the beam condition at the CSR and the major physics backgrounds are carefully taken into account. We conclude that the ITE is more suitable for such a study due to better detector acceptance and higher beam density. At the maximum designed luminosity (1034 cm-2 s-1), η→e+e- events can be collected every ~400 seconds at the CSR. With a mass resolution of 1 MeV, the expected signal-to-background (S/B) ratio is around 1.
Tissue imaging using full field optical coherence microscopy with short multimode fiber probe
NASA Astrophysics Data System (ADS)
Sato, Manabu; Eto, Kai; Goto, Tetsuhiro; Kurotani, Reiko; Abe, Hiroyuki; Nishidate, Izumi
2018-03-01
In achieving minimally invasive accessibility to deeply located regions the size of the imaging probes is important. We demonstrated full-field optical coherence tomography (FF-OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe of 50 μm core diameter, 125 μm diameter, and 7.4 mm length for optical communications. The axial resolution was measured to be 2.14 μm and the lateral resolution was also evaluated to be below 4.38 μm using a test pattern (TP). The spatial mode and polarization characteristics of SMMF were evaluated. Inserting SMMF to in vivo rat brain, 3D images were measured and 2D information of nerve fibers was obtained. The feasibility of an SMMF as an ultrathin forward-imaging probe in FF-OCM has been demonstrated.
NASA Astrophysics Data System (ADS)
Li, Jiawen; Quirk, Bryden C.; Noble, Peter B.; Kirk, Rodney W.; Sampson, David D.; McLaughlin, Robert A.
2017-10-01
Transbronchial needle aspiration (TBNA) of small lesions or lymph nodes in the lung may result in nondiagnostic tissue samples. We demonstrate the integration of an optical coherence tomography (OCT) probe into a 19-gauge flexible needle for lung tissue aspiration. This probe allows simultaneous visualization and aspiration of the tissue. By eliminating the need for insertion and withdrawal of a separate imaging probe, this integrated design minimizes the risk of dislodging the needle from the lesion prior to aspiration and may facilitate more accurate placement of the needle. Results from in situ imaging in a sheep lung show clear distinction between solid tissue and two typical constituents of nondiagnostic samples (adipose and lung parenchyma). Clinical translation of this OCT-guided aspiration needle holds promise for improving the diagnostic yield of TBNA.
Survey of microsatellite DNA in pine
C. S. Echt; P. May-Marquardt
1997-01-01
A large insert genomic library from eastern white pine (Pinus strobus) was probed for the microsatellite motifs (AC)n and (AG)n, all 10 trinucleotide motifs, and 22 of the 33 possible tetranucleotide motifs. For comparison with a species from a different subgenus, a loblolly pine (Pinus taeda...
Survey of microsatellite DNA in pine
Craig S. Echt; P. May-Marquardt
1997-01-01
A large insert genomic library from eastern white pine (Pinus strobus) was probed for the microsatellite motifs (AC)n and (AG)n, all 10 trinucleotide motifs, and 22 of the 33 possible tetranucleotide motifs. For comparison with a species from a different subgenus, a loblolly pine (Pinus taeda) genomic...
A simple, efficient resistance soldering apparatus
NASA Technical Reports Server (NTRS)
Vermillion, C. M.
1972-01-01
Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.
Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert
NASA Technical Reports Server (NTRS)
Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.
2001-01-01
Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers can be corrupted by emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.
Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert
NASA Technical Reports Server (NTRS)
Jones, Matthew R.; Farmer, Jeffrey T.; Breeding, Shawn P.
1999-01-01
Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers are corrupted due to emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.
Mobile Interspersed Repeats Are Major Structural Variants in the Human Genome
Huang, Cheng Ran Lisa; Schneider, Anna M.; Lu, Yunqi; Niranjan, Tejasvi; Shen, Peilin; Robinson, Matoya A.; Steranka, Jared P.; Valle, David; Civin, Curt I.; Wang, Tao; Wheelan, Sarah J.; Ji, Hongkai; Boeke, Jef D.; Burns, Kathleen H.
2010-01-01
Summary Characterizing structural variants in the human genome is of great importance, but a genome wide analysis to detect interspersed repeats has not been done. Thus, the degree to which mobile DNAs contribute to genetic diversity, heritable disease, and oncogenesis remains speculative. We perform transposon insertion profiling by microarray (TIP-chip) to map human L1(Ta) retrotransposons (LINE-1 s) genome-wide. This identified numerous novel human L1(Ta) insertional polymorphisms with highly variant allelic frequencies. We also explored TIP-chip's usefulness to identify candidate alleles associated with different phenotypes in clinical cohorts. Our data suggest that the occurrence of new insertions is twice as high as previously estimated, and that these repeats are under-recognized as sources of human genomic and phenotypic diversity. We have just begun to probe the universe of human L1(Ta) polymorphisms, and as TIP-chip is applied to other insertions such as Alu SINEs, it will expand the catalog of genomic variants even further. PMID:20602999
Grady, Janet L; Kehrer, Rosemary G; Trusty, Carole E; Entin, Eileen B; Entin, Elliot E; Brunye, Tad T
2008-09-01
Simulation technologies are gaining widespread acceptance across a variety of educational domains and applications. The current research examines whether basic nursing procedure training with high-fidelity versus low-fidelity mannequins results in differential skill acquisition and perceptions of simulator utility. Fifty-two first-year students were taught nasogastric tube and indwelling urinary catheter insertion in one of two ways. The first group learned nasogastric tube and urinary catheter insertion using high-fidelity and low-fidelity mannequins, respectively, and the second group learned nasogastric tube and urinary catheter insertion using low-fidelity and high-fidelity mannequins, respectively. The dependent measures included student performance on nasogastric tube and urinary catheter insertion testing, as measured by observer-based instruments, and self-report questionnaires probing student attitudes about the use of simulation in nursing education. Results demonstrated higher performance with high-fidelity than with low-fidelity mannequin training. In response to a self-report posttraining questionnaire, participants expressed a more positive attitude toward the high-fidelity mannequin, especially regarding its responsiveness and realism.
NASA Technical Reports Server (NTRS)
Jorns, Benjamin A.; Goebel, Dan M.; Hofer, Richard R.
2015-01-01
An experimental investigation is presented to quantify the effect of high-speed probing on the plasma parameters inside the discharge chamber of a 6-kW Hall thruster. Understanding the nature of these perturbations is of significant interest given the importance of accurate plasma measurements for characterizing thruster operation. An array of diagnostics including a high-speed camera and embedded wall probes is employed to examine in real time the changes in electron temperature and plasma potential induced by inserting a high-speed reciprocating Langmuir probe into the discharge chamber. It is found that the perturbations onset when the scanning probe is downstream of the electron temperature peak, and that along channel centerline, the perturbations are best characterized as a downstream shift of plasma parameters by 15-20% the length of the discharge chamber. A parametric study is performed to investigate techniques to mitigate the observed probe perturbations including varying probe speed, probe location, and operating conditions. It is found that the perturbations largely disappear when the thruster is operated at low power and low discharge voltage. The results of this mitigation study are discussed in the context of recommended methods for generating unperturbed measurements of the discharge chamber plasma.
Yuan, Christina M; Prince, Lisa K; Zwettler, Amy J; Nee, Robert; Oliver, James D; Abbott, Kevin C
2014-11-01
Entrustable professional activities (EPAs) are complex tasks representing vital physician functions in multiple competencies, used to demonstrate trainee development along milestones. Managing a nephrology outpatient clinic has been proposed as an EPA for nephrology fellowship training. Retrospective cohort study of nephrology fellow outpatient clinic performance using a previously validated chart audit tool. Outpatient encounter chart audits for training years 2008-2009 through 2012-2013, corresponding to participation in the Nephrology In-Training Examination (ITE). A median of 7 auditors (attending nephrologists) audited a mean of 1,686±408 (SD) charts per year. 18 fellows were audited; 12, in both of their training years. Proportion of chart audit and quality indicator deficiencies. Longitudinal deficiency and ITE performance. Among fellows audited in both their training years, chart audit deficiencies were fewer in the second versus the first year (5.4%±2.0% vs 17.3%±7.0%; P<0.001) and declined between the first and second halves of the first year (22.2%±6.4% vs 12.3%±9.5%; P=0.002). Most deficiencies were omission errors, regardless of training year. Quality indicator deficiencies for hypertension and chronic kidney disease-associated anemia recognition and management were fewer during the second year (P<0.001). Yearly audit deficiencies ≥5% were associated with an ITE score less than the 25th percentile for second-year fellows (P=0.03), with no significant association for first-year fellows. Auditor-reported deficiencies declined between the first and second halves of the year (17.0% vs 11.1%; P<0.001), with a stable positive/neutral comment rate (17.3% vs 17.8%; P=0.6), suggesting that the decline was not due to auditor fatigue. Retrospective design and small trainee numbers. Managing a nephrology outpatient clinic is an EPA. The chart audit tool was used to assess longitudinal fellow performance in managing a nephrology outpatient clinic. Failure to progress may be quantitatively identified and remediated. The tool identifies deficiencies in all 6 competencies, not just medical knowledge, the primary focus of the ITE and the nephrology subspecialty board examination. Published by Elsevier Inc.
Li, Yan; Deng, Jianxin; Zhou, Jun; Li, Xueen
2016-11-01
Corresponding to pre-puncture and post-puncture insertion, elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation are investigated, respectively. Elastic mechanical properties in pre-puncture are investigated through pre-puncture needle insertion experiments using whole porcine brains. A linear polynomial and a second order polynomial are fitted to the average insertion force in pre-puncture. The Young's modulus in pre-puncture is calculated from the slope of the two fittings. Viscoelastic mechanical properties of brain tissues in post-puncture insertion are investigated through indentation stress relaxation tests for six interested regions along a planned trajectory. A linear viscoelastic model with a Prony series approximation is fitted to the average load trace of each region using Boltzmann hereditary integral. Shear relaxation moduli of each region are calculated using the parameters of the Prony series approximation. The results show that, in pre-puncture insertion, needle force almost increases linearly with needle displacement. Both fitting lines can perfectly fit the average insertion force. The Young's moduli calculated from the slope of the two fittings are worthy of trust to model linearly or nonlinearly instantaneous elastic responses of brain tissues, respectively. In post-puncture insertion, both region and time significantly affect the viscoelastic behaviors. Six tested regions can be classified into three categories in stiffness. Shear relaxation moduli decay dramatically in short time scales but equilibrium is never truly achieved. The regional and temporal viscoelastic mechanical properties in post-puncture insertion are valuable for guiding probe insertion into each region on the implanting trajectory.
... pylori . The endoscopy is sometimes used with a test called a pH probe in which a small wire is inserted into the lower part of the esophagus to measure the amount of acid going into that area. If there's any evidence of inflammation, the doctor will test for H. pylori . This test is important because ...
Endocavity Ultrasound Probe Manipulators
Stoianovici, Dan; Kim, Chunwoo; Schäfer, Felix; Huang, Chien-Ming; Zuo, Yihe; Petrisor, Doru; Han, Misop
2014-01-01
We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots. The 4-DoF robot provides unrestricted manipulation of the endocavity probe. With the 3-DoF robot the insertion motion of the probe must be adjusted manually, but the device is simpler and may also be used to manipulate external-body probes. The robots enabled a novel surgical approach of using intraoperative image-based navigation during robot-assisted laparoscopic prostatectomy (RALP), performed with concurrent use of two robotic systems (Tandem, T-RALP). Thus far, a clinical trial for evaluation of safety and feasibility has been performed successfully on 46 patients. This paper describes the architecture and design of the robots, the two prototypes, control features related to safety, preclinical experiments, and the T-RALP procedure. PMID:24795525
Phoenix Conductivity Probe after Extraction from Martian Soil on Sol 99
NASA Technical Reports Server (NTRS)
2008-01-01
NASA's Phoenix Mars Lander inserted the four needles of its thermal and conductivity probe into Martian soil during the 98th Martian day, or sol, of the mission and left it in place until Sol 99 (Sept. 4, 2008). The Surface Stereo Imager on Phoenix took this image on the morning of Sol 99 after the probe was lifted away from the soil. This imaging served as a check of whether soil had stuck to the needles. The thermal and conductivity probe measures how fast heat and electricity move from one needle to an adjacent one through the soil or air between the needles. Conductivity readings can be indicators about water vapor, water ice and liquid water. The probe is part of Phoenix's Microscopy, Electrochemistry and Conductivity suite of instruments. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.Trip generation studies for special generators.
DOT National Transportation Integrated Search
2010-02-01
This research examines the effects of town centers and senior housing developments on : surrounding roadways and nearby transit. The Institute of Transportation Engineers (ITE) : Trip Generation Manual, which determines number of trips produced or at...
NASA Astrophysics Data System (ADS)
Lockwood, Jeffrey F.
1996-03-01
Falling stars have always had a magical aura, whether people think of them as omens or simply as natural fireworks. So why squash that natural fascination by making students memorize the difference between -ites and -oids?
NASA Astrophysics Data System (ADS)
Purcell, E. K.; Seymour, J. P.; Yandamuri, S.; Kipke, D. R.
2009-08-01
In the published article, an error was made in figure 5. Specifically, the three-month, NSC-seeded image is a duplicate of the six-week image, and the one-day, probe alone image is a duplicate of the three-month image. The corrected figure is reproduced below. Figure 5 Figure 5. Glial encapsulation of each probe condition over the 3 month time course. Ox-42 labeled microglia and GFAP labeled astrocytes are shown. Images are taken from probes implanted in the same animal at each time point. NSC seeding was associated with reduced non-neuronal density at 1 day post-implantation in comparison to alginate coated probes and at the 1 week time point in comparison to untreated probes (P < 0.001). Glial activation is at its overall peak 1 week after insertion. A thin encapsulation layer surrounds probes at the 6 week and 3 month time points, with NSC-seeded probes having the greatest surrounding non-neuronal density P < 0.001). Interestingly, microglia appeared to have a ramified, or `surveilling', morphology surrounding a neural stem cell-alginate probe initially, whereas activated cells with an amoeboid structure were found near an alginate probe in the same hemisphere of one animal (left panels).
Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H
2012-06-01
The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.
Miniature standoff Raman probe for neurosurgical applications
NASA Astrophysics Data System (ADS)
Stevens, Oliver A. C.; Hutchings, Joanne; Gray, William; Vincent, Rosa Louise; Day, John C.
2016-08-01
Removal of intrinsic brain tumors is a delicate process, where a high degree of specificity is required to remove all of the tumor tissue without damaging healthy brain. The accuracy of this process can be greatly enhanced by intraoperative guidance. Optical biopsies using Raman spectroscopy are a minimally invasive and lower-cost alternative to current guidance methods. A miniature Raman probe for performing optical biopsies of human brain tissue is presented. The probe allows sampling inside a conventional stereotactic brain biopsy system: a needle of length 200 mm and inner diameter of 1.8 mm. By employing a miniature stand-off Raman design, the probe removes the need for any additional components to be inserted into the brain. Additionally, the probe achieves a very low internal silica background while maintaining good collection of Raman signal. To illustrate this, the probe is compared with a Raman probe that uses a pair of optical fibers for collection. The miniature stand-off Raman probe is shown to collect a comparable number of Raman scattered photons, but the Raman signal to background ratio is improved by a factor of five at Raman shifts below ˜500 cm-1. The probe's suitability for use on tissue is demonstrated by discriminating between different types of healthy porcine brain tissue.
NASA Technical Reports Server (NTRS)
DeRoshia, C. W.; Greenleaf, J. E.
1993-01-01
The study was designed to determine if performance and mood impairments occur in bed-rested subjects, and if different exercise-training regimens modify or prevent them. Eighteen normal, healthy men were divided on the basis of age, peak oxygen uptake, and maximal isometric knee extension strength into three similar groups: no exercise (NOE), isotonic exercise (ITE), and isokinetic exercise (IKE). A 15-min battery of 10 performance tests and 8 mood and 2 sleep scales were administered daily during ambulatory control, 30 d of absolute bed rest (BR), and 4 d of ambulatory recovery. Performance test proficiency increased (p < 0.05) for all three groups during BR in 7 of 10 tests and there were no consistent significant differences between the three groups. However, during BR, the ITE group was distinguished from the other groups by a decline (p < 0.05) in the activation mood dimension and in two of its constituent scales (motivation and concentration), and by improvement (p < 0.05) in the trouble-falling-asleep and psychological-tension scales. Since few deleterious changes in performance and mood occurred in the three groups and did not exceed baseline ambulatory levels, we conclude that mood and performance did not deteriorate in response to prolonged BR and were not altered by exercise training. However, the decline in activation mood scales in the ITE group may reflect overtraining or excess total workload in this group.
Quintana, Francisco J.; Murugaiyan, Gopal; Farez, Mauricio F.; Mitsdoerffer, Meike; Tukpah, Ann-Marcia; Burns, Evan J.; Weiner, Howard L.
2010-01-01
The ligand-activated transcription factor aryl hydrocarbon receptor (AHR) participates in the differentiation of FoxP3+ Treg, Tr1 cells, and IL-17–producing T cells (Th17). Most of our understanding on the role of AHR on the FoxP3+ Treg compartment results from studies using the toxic synthetic chemical 2,3,7,8-tetrachlorodibenzo-p-dioxin. Thus, the physiological relevance of AHR signaling on FoxP3+ Treg in vivo is unclear. We studied mice that carry a GFP reporter in the endogenous foxp3 locus and a mutated AHR protein with reduced affinity for its ligands, and found that AHR signaling participates in the differentiation of FoxP3+ Treg in vivo. Moreover, we found that treatment with the endogenous AHR ligand 2-(1′H-indole-3′-carbonyl)-thiazole-4-carboxylic acid methyl ester (ITE) given parenterally or orally induces FoxP3+ Treg that suppress experimental autoimmune encephalomyelitis. ITE acts not only on T cells, but also directly on dendritic cells to induce tolerogenic dendritic cells that support FoxP3+ Treg differentiation in a retinoic acid-dependent manner. Thus, our work demonstrates that the endogenous AHR ligand ITE promotes the induction of active immunologic tolerance by direct effects on dendritic and T cells, and identifies nontoxic endogenous AHR ligands as potential unique compounds for the treatment of autoimmune disorders. PMID:21068375
The Cape Ghir filament system in August 2009 (NW Africa)
NASA Astrophysics Data System (ADS)
Sangrà, Pablo; Troupin, Charles; Barreiro-González, Beatriz; Desmond Barton, Eric; Orbi, Abdellatif; Arístegui, Javier
2015-06-01
In the framework of the Canaries-Iberian marine ecosystem Exchanges (CAIBEX) experiment, an interdisciplinary high-resolution survey was conducted in the NW African region of Cape Ghir (30°38'N) during August 2009. The anatomy of a major filament is investigated on scales down to the submesoscale using in situ and remotely sensed data. The filament may be viewed as a system composed of three intimately connected structures: a small, shallow, and cold filament embedded within a larger, deeper, and cool filament and an intrathermocline anticyclonic eddy (ITE). The cold filament, which stretches 110 km offshore, is a shallow feature 60 m deep and 25 km wide, identified by minimal surface temperatures and rich in chlorophyll a. This structure comprises two asymmetrical submesoscale (˜18 km) fronts with jets flowing in opposite directions. The cold filament is embedded near the equatorward boundary of a much broader region of approximately 120 km width and 150 m depth that forms the cool filament and stretches at least 200 km offshore. This cool region, partly resulting from the influence of cold filament, is limited by two asymmetrical mesoscale (˜50 km) frontal boundaries. At the ITE, located north of the cold filament, we observe evidence of downwelling as indicated by a relatively high concentration of particles extending from the surface to more than 200 m depth. We hypothesize that this ITE may act as a sink of carbon and thus the filament system may serve dual roles of offshore carbon export and carbon sink.
Craig, Elizabeth S; Clemens, Mark W; Koshy, John C; Wren, James; Hong, Zhang; Butler, Charles; Garvey, Patrick; Selber, Jesse; Kronowitz, Steven
2018-05-24
Despite increasing literature support for the use of acellular dermal matrix (ADM) in expander-based breast reconstruction, the effect of ADM on clinical outcomes in the presence of post-mastectomy radiation therapy (PMRT) has not been well described. To analyze the impact ADM plays on clinical outcomes on immediate tissue expander (ITE) reconstruction undergoing PMRT. We retrospectively reviewed patients who underwent ITE breast reconstruction from 2004 to 2014 at MD Anderson Cancer Center. Patients were categorized into four cohorts: ADM, ADM with PMRT, non-ADM, and non-ADM with PMRT. Outcomes and complications were compared between cohorts. Over ten years, 957 patients underwent ITE reconstruction (683 non-ADM, 113 non-ADM with PMRT, 486 ADM, and 88 ADM with PMRT) with 1,370 reconstructions. Overall complication rates for the ADM and non-ADM cohorts were 39.0 and 16.7%, respectively (p <0.001). Within both cohorts, mastectomy skin flap necrosis (MSFN) was the most common complication, followed by infection. ADM use was associated with a significantly higher rate of infections and seromas in both radiated and non-radiated groups; however, when comparing radiated cohorts, the incidence of explantation was significantly lower with the use of ADM. The decision to use ADM for expander-based breast reconstruction should be performed with caution, given higher overall rates of complications, including infections and seromas. There may, however, be a role for ADM in cases requiring PMRT, as the overall incidence of implant failure is lower than non-ADM cases.
Lampis, Silvia; Ferrari, Anita; Cunha-Queda, A Cristina F; Alvarenga, Paula; Di Gregorio, Simona; Vallini, Giovanni
2009-09-01
Selenium is a trace metalloid of global environmental concern. The boundary among its essentiality, deficiency, and toxicity is narrow and mainly depends on the chemical forms and concentrations in which this element occurs. Different plant species-including Brassica juncea-have been shown to play a significant role in Se removal from soil as well as water bodies. Furthermore, the interactions between such plants, showing natural capabilities of metal uptake and their rhizospheric microbial communities, might be exploited to increase both Se scavenging and vegetable biomass production in order to improve the whole phytoextraction efficiency. The aim of the present study was to evaluate the capability of selenite removal of B. juncea grown in hydroponic conditions on artificially spiked effluents. To optimize phytoextraction efficiency, interactions between B. juncea and rhizobacteria were designedly elicited. Firstly, B. juncea was grown on water-filtering agriperlite beds in the presence of three different selenite concentrations, namely, 0.2, 1.0, and 2.0 mM. Plant growth was measured after 3 and 6 weeks of incubation in order to establish the selenite concentration at which the best plant biomass production could be obtained. Afterwards, water-filtering agriperlite beds were inoculated either with a selenium-acclimated microbial community deriving from the rhizosphere of B. juncea grown, erstwhile, in a selenite-amended soil or with axenic cultures of two bacterial strains, vicelike Bacillus mycoides SeITE01 and Stenotrophomonas maltophilia SeITE02, previously isolated and described for their high resistance to selenite. These latter were seeded separately or as a dual consortium. Selenite was amended at a final concentration of 1.0 mM. Total Se content in plant tissues (both shoots and roots), plant biomass production, and persistence of bioaugmented microbial inocula during the experimental time were monitored. Moreover, parameters such as bioconcentration factor (BF) and phytoextraction efficiency (PE) were determined at the end of the testing run to evaluate the effects of the different bioaugmentation strategies adopted on selenite phytoextraction efficiency of B. juncea. A general but significant increase in capacity to extract and transport selenium to the epigeous plant compartments was recorded in B. juncea grown in beds augmented with microbial inocula, except for the treatment with B. mycoides SeITE01 alone. Nevertheless, a severe decrease in vegetable biomass production was observed after all microbial treatments with the exception of the plants that had received only S. maltophilia SeITE02. Actually, an increase in selenium phytoextraction efficiency up to 65% was observed in B. juncea, when this bacterial strain was inoculated. Emendation of B. juncea grown in water-filtering beds with a Se(IV)-acclimated microbial community caused a higher Se uptake along with a reduction of plant biomass yield with respect to plants grown without addition of the same bacterial inoculum. The increase of selenium BF in shoots suggests that the Se(IV)-acclimated microbial community not only elicited the plant capacity to absorb selenite, but also did improve the capacity to transport the metalloid to the epigeous compartments. On the other hand, the reduction in plant biomass yield might be related exactly to this improved capability of B. juncea to accumulate selenium at concentrations that are actually toxic for plants. Differently, addition of two selenite-resistant bacterial strains, namely, S. maltophilia SeITE02 and B. mycoides SEITE01, had weaker effects on plant biomass production when compared to those recorded in the presence of the Se(IV)-adapted microbial community. In particular, inoculation of water-filtering beds with the SeITE02 strain alone was the sole strategy resulting in a positive effect on both plant biomass production in stressful conditions and the capacity of shoots to accumulate selenium. In fact, its putative ability of reducing Se(IV) to organo-Se compounds significantly enhanced either selenium absorption by the plants or active metalloid translocation to epigeous parts. Bioaugmentation with the bacterial strain S. malthophila SeITE02 is suggested to elicit selenite phytoextraction efficiency in B. juncea. Manipulation of synergistic interactions between plants having phytoextraction capabilities and their associated rhizobacteria may enhance already consolidated treatment processes aimed to detoxify selenite laden wastewater.
Lambda Probe Measurements of Laboratory Spheromaks
NASA Astrophysics Data System (ADS)
Jorne, E.; Bellan, P. M.; Hsu, S. C.; Moynihan, C.
2003-10-01
A combined current and magnetic probe (lambda probe) has been constructed and is being tested for the purpose of investigating the behavior of spheromaks formed by the Caltech planar spheromak gun. The probe consists of a 1.5cm diameter, 52 turn Rogowski coil and a single loop magnetic coil, housed in a ceramic shell attached to a 95cm long hollow, steel shaft. A high voltage power supply was used to test the probe's ability to measure pulsed currents with submicrosecond rise times. A calibrated current pulse was provided by a 1μF capacitor discharged by a krytron switch to a low inductance circuit. Magnetic calibration was obtained by using the capacitor bank to power a 16cm diameter Helmholtz coil. Both magnetic and current calibration were in good agreement with estimates based on geometry. An existing steel shaft will be replaced by a ceramic shaft in order to minimize undesired effects on the plasma by a conductor. Once sealed with epoxy, the probe will be ready for insertion into the vacuum chamber and used to measure the magnetic field and parallel current during spheromak formation.
Optimizing the specificity of nucleic acid hybridization.
Zhang, David Yu; Chen, Sherry Xi; Yin, Peng
2012-01-22
The specific hybridization of complementary sequences is an essential property of nucleic acids, enabling diverse biological and biotechnological reactions and functions. However, the specificity of nucleic acid hybridization is compromised for long strands, except near the melting temperature. Here, we analytically derived the thermodynamic properties of a hybridization probe that would enable near-optimal single-base discrimination and perform robustly across diverse temperature, salt and concentration conditions. We rationally designed 'toehold exchange' probes that approximate these properties, and comprehensively tested them against five different DNA targets and 55 spurious analogues with energetically representative single-base changes (replacements, deletions and insertions). These probes produced discrimination factors between 3 and 100+ (median, 26). Without retuning, our probes function robustly from 10 °C to 37 °C, from 1 mM Mg(2+) to 47 mM Mg(2+), and with nucleic acid concentrations from 1 nM to 5 µM. Experiments with RNA also showed effective single-base change discrimination.
Scolaro, Loretta; Lorenser, Dirk; Madore, Wendy-Julie; Kirk, Rodney W.; Kramer, Anne S.; Yeoh, George C.; Godbout, Nicolas; Sampson, David D.; Boudoux, Caroline; McLaughlin, Robert A.
2015-01-01
Molecular imaging using optical techniques provides insight into disease at the cellular level. In this paper, we report on a novel dual-modality probe capable of performing molecular imaging by combining simultaneous three-dimensional optical coherence tomography (OCT) and two-dimensional fluorescence imaging in a hypodermic needle. The probe, referred to as a molecular imaging (MI) needle, may be inserted tens of millimeters into tissue. The MI needle utilizes double-clad fiber to carry both imaging modalities, and is interfaced to a 1310-nm OCT system and a fluorescence imaging subsystem using an asymmetrical double-clad fiber coupler customized to achieve high fluorescence collection efficiency. We present, to the best of our knowledge, the first dual-modality OCT and fluorescence needle probe with sufficient sensitivity to image fluorescently labeled antibodies. Such probes enable high-resolution molecular imaging deep within tissue. PMID:26137379
Stauffer, Hans U; Miller, Joseph D; Roy, Sukesh; Gord, James R; Meyer, Terrence R
2012-03-21
A narrowband, time-asymmetric probe pulse is introduced into the hybrid femtosecond/picosecond rotational coherent anti-Stokes Raman scattering (fs/ps RCARS) technique to provide accurate and precise single-shot, high-repetition-rate gas-phase thermometric measurements. This narrowband pulse-generated by inserting a Fabry-Pérot étalon into the probe-pulse beam path-enables frequency-domain detection of pure-rotational transitions. The unique time-asymmetric nature of this pulse, in turn, allows for detection of resonant Raman-active rotational transitions free of signal contamination by nonresonant four-wave-mixing processes while still allowing detection at short probe-pulse delays, where collisional dephasing processes are negligible. We demonstrate that this approach provides excellent single-shot thermometric accuracy (<1% error) and precision (~2.5%) in gas-phase environments. © 2012 American Institute of Physics
Szostak, Katarzyna M; Grand, Laszlo; Constandinou, Timothy G
2017-01-01
Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes-microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges.
cDNA cloning and analysis of RNA 2 of a Prunus stem pitting isolate of tomato ringspot virus.
Hadidi, A; Powell, C A
1991-10-01
Recombinant plasmids containing sequences derived from the genome of a tomato ringspot virus (TomRSV) isolate associated with both stem pitting disease of stone fruits and apple union necrosis and decline were constructed. Selected inserts were subcloned into the polylinker region of the SP6 transcription vector pSP64. Using the SP6 promoter flanking this region, high specific activity 32P-labelled cRNA probes were generated by SP6 RNA polymerase. cRNA probes were specific for TomRSV RNA 2 present in purified virions or in extracts from woody and herbacous hosts. No sequence relatedness was detected between TomRSV RNA 2 and genomic RNA from tobacco ringspot, arabis mosaic, strawberry latent ringspot, or cucumber mosaic virus in Northern blot analysis using TomRSV cRNA probes. These probes detected TomRSV infection in woody and herbaceous hosts in dot-blot hybridization assays.
Microdialysis of glucose in subcutaneous adipose tissue up to 3 weeks in healthy volunteers.
Wientjes, K J; Vonk, P; Vonk-van Klei, Y; Schoonen, A J; Kossen, N W
1998-09-01
To measure possible changes in dialysate glucose concentrations over time, to validate the diffusional model for glucose transport from tissue to the probe, and to evaluate the actual glucose concentration in adipose tissue. Glucose concentrations in the subcutaneous adipose tissue of five healthy subjects (age 25 +/- 2.7 years, BMI 23.2 +/- 2.3 kg/m2 [mean +/- SD]) were measured by the microdialysis technique and compared with blood glucose. We applied microdialysis probes with hollow fibers of various membrane length (10-35 mm), used eight perfusion flow rates (0.5-20 microl/min), and perfused four glucose solutions (0.0, 2.8, 8.3, 11.1 mmol/l). After implantation, a substantial decrease in glucose recovery to the lowest value of 26 +/- 10% of the final plateau value was noted during the first few hours (n = 4). Recovery increased and stabilized after 5-9 days at 84.0 +/- 7.4% of capillary blood glucose when a flow rate of 0.5 microl/min was applied. According to the zero net-flux method, the glucose concentration in equilibrium, Cequi, with the surrounding tissue can be obtained. This concentration also decreases; however, 1 h after recovery, Cequi increases again over 1 or 2 days to a stable value that is not significantly different from the measured capillary blood glucose (P < 0.05). Using various perfusion flow rates and probes (membrane length 10-35 mm), it is shown that diffusion is the rate-limiting process for glucose transport through tissue. Insertion of the microdialysis probes causes damage to the adipose cells and the vascular bed around the probe. Glucose recovery decreases because of a lower blood supply. In 5-9 days, glucose recovery increases; apparently, this time is needed to repair the microstructure of tissue around the probe. After stabilization of the recovery, no loss of probe permeability, which is due to biocompatibility problems, was seen. The change during the 2 days in equilibrium concentration is probably caused by an inflammation reaction that consumes glucose around the probe. The individual increase in recovery during the 1st days after probe insertion until a stable plateau value is reached (flow rate >0 microl/min) is complicated for short-term clinical glucose measurements in adipose tissue. After stabilization, the mean equilibrium concentration of all subjects was equal to the mean capillary blood glucose concentration. Therefore, we conclude that capillary blood glucose concentration probably is the driving force for diffusion through the capillary wall into the probe and is not some interstitial concentration.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
Hjelm, L N; Branstrom, A A; Warren, R L
1990-01-01
An 800-base-pair HindIII-PstI fragment that flanks a hot spot for Tn7 insertion was isolated from the chromosome of Pseudomonas aeruginosa and cloned into pUC12. The fragment was used to probe XhoI digests of genomic DNA from 18 P. aeruginosa isolates collected from sputum samples of seven cystic fibrosis patients. Only two XhoI restriction fragment length polymorphisms (RFLPs), of 3.7 and 7.7 kilobases (kb), were detected. Isolate WSU3531-1 (3.7-kb XhoI fragment) and WSU3860 (7.7-kb XhoI fragment), while isolated from the same patient, showed different RFLPs. Serial passages of isolate WSU3531-1 demonstrated that this strain was phenotypically stable. In contrast, colony and pigment variants were readily isolated at a frequency of 1% from serial passages of isolate WSU3860. When XhoI-digested genomic DNA from phenotypic variants of serially passaged WSU3860 were probed with the 800-base-pair HindIII-PstI fragment, the probe hybridized to a 10.4-kb XhoI fragment from three isolates. Restriction analysis of the genomic DNA digested with a variety of restriction enzymes showed that a 2.7-kb insertion occurred in the same region for all three isolates. There appeared to be no correlation between changes in the RFLP and changes in colony morphology. Images PMID:1977762
A low molecular weight artificial RNA of unique size with multiple probe target regions
NASA Technical Reports Server (NTRS)
Pitulle, C.; Dsouza, L.; Fox, G. E.
1997-01-01
Artificial RNAs (aRNAs) containing novel sequence segments embedded in a deletion mutant of Vibrio proteolyticus 5S rRNA have previously been shown to be expressed from a plasmid borne growth rate regulated promoter in E. coli. These aRNAs accumulate to high levels and their detection is a promising tool for studies in molecular microbial ecology and in environmental monitoring. Herein a new construct is described which illustrates the versatility of detection that is possible with aRNAs. This 3xPen aRNA construct carries a 72 nucleotide insert with three copies of a unique 17 base probe target sequence. This aRNA is 160 nucleotides in length and again accumulates to high levels in the E. coli cytoplasm without incorporating into ribosomes. The 3xPen aRNA illustrates two improvements in detection. First, by appropriate selection of insert size, we obtained an aRNA which provides a unique and hence, easily quantifiable peak, on a high resolution gel profile of low molecular weight RNAs. Second, the existence of multiple probe targets results in a nearly commensurate increase in signal when detection is by hybridization. These aRNAs are naturally amplified and carry sequence segments that are not found in known rRNA sequences. It thus may be possible to detect them directly. An experimental step involving RT-PCR or PCR amplification of the gene could therefore be avoided.
Aeroshell Design Techniques for Aerocapture Entry Vehicles
NASA Technical Reports Server (NTRS)
Dyke, R. Eric; Hrinda, Glenn A.
2004-01-01
A major goal of NASA s In-Space Propulsion Program is to shorten trip times for scientific planetary missions. To meet this challenge arrival speeds will increase, requiring significant braking for orbit insertion, and thus increased deceleration propellant mass that may exceed launch lift capabilities. A technology called aerocapture has been developed to expand the mission potential of exploratory probes destined for planets with suitable atmospheres. Aerocapture inserts a probe into planetary orbit via a single pass through the atmosphere using the probe s aeroshell drag to reduce velocity. The benefit of an aerocapture maneuver is a large reduction in propellant mass that may result in smaller, less costly missions and reduced mission cruise times. The methodology used to design rigid aerocapture aeroshells will be presented with an emphasis on a new systems tool under development. Current methods for fast, efficient evaluations of structural systems for exploratory vehicles to planets and moons within our solar system have been under development within NASA having limited success. Many systems tools that have been attempted applied structural mass estimation techniques based on historical data and curve fitting techniques that are difficult and cumbersome to apply to new vehicle concepts and missions. The resulting vehicle aeroshell mass may be incorrectly estimated or have high margins included to account for uncertainty. This new tool will reduce the guesswork previously found in conceptual aeroshell mass estimations.
NASA Astrophysics Data System (ADS)
Ogawa, Kuniyasu; Haishi, Tomoyuki; Aoki, Masaru; Hasegawa, Hiroshi; Morisaka, Shinichi; Hashimoto, Seitaro
2017-01-01
A small radio-frequency (rf) coil inserted into a polymer electrolyte fuel cell (PEFC) can be used to acquire nuclear magnetic resonance (NMR) signals from the water in a membrane electrode assembly (MEA) or in oxygen gas channels in the PEFC. Measuring the spatial distribution of the water in a large PEFC requires using many rf probes, so an NMR measurement system which acquires NMR signals from 128 rf probes at intervals of 0.5 s was manufactured. The system has eight rf transceiver units with a field-programmable gate array (FPGA) for modulation of the excitation pulse and quadrature phase detection of the NMR signal, and one control unit with two ring buffers for data control. The sequence data required for the NMR measurement were written into one ring buffer. The acquired NMR signal data were then written temporarily into the other ring buffer and then were transmitted to a personal computer (PC). A total of 98 rf probes were inserted into the PEFC that had an electrical generation area of 16 cm × 14 cm, and the water generated in the PEFC was measured when the PEFC operated at 100 A. As a result, time-dependent changes in the spatial distribution of the water content in the MEA and the water in the oxygen gas channels were obtained.
Method for producing labeled single-stranded nucleic acid probes
Dunn, John J.; Quesada, Mark A.; Randesi, Matthew
1999-10-19
Disclosed is a method for the introduction of unidirectional deletions in a cloned DNA segment. More specifically, the method comprises providing a recombinant DNA construct comprising a DNA segment of interest inserted in a cloning vector, the cloning vector having an f1 endonuclease recognition sequence adjacent to the insertion site of the DNA segment of interest. The recombinant DNA construct is then contacted with the protein pII encoded by gene II of phage f1 thereby generating a single-stranded nick. The nicked DNA is then contacted with E. coli Exonuclease III thereby expanding the single-stranded nick into a single-stranded gap. The single-stranded gapped DNA is then contacted with a single-strand-specific endonuclease thereby producing a linearized DNA molecule containing a double-stranded deletion corresponding in size to the single-stranded gap. The DNA treated in this manner is then incubated with DNA ligase under conditions appropriate for ligation. Also disclosed is a method for producing single-stranded DNA probes. In this embodiment, single-stranded gapped DNA, produced as described above, is contacted with a DNA polymerase in the presence of labeled nucleotides to fill in the gap. This DNA is then linearized by digestion with a restriction enzyme which cuts outside the DNA segment of interest. The product of this digestion is then denatured to produce a labeled single-stranded nucleic acid probe.
A semi-automated vascular access system for preclinical models
NASA Astrophysics Data System (ADS)
Berry-Pusey, B. N.; Chang, Y. C.; Prince, S. W.; Chu, K.; David, J.; Taschereau, R.; Silverman, R. W.; Williams, D.; Ladno, W.; Stout, D.; Tsao, T. C.; Chatziioannou, A.
2013-08-01
Murine models are used extensively in biological and translational research. For many of these studies it is necessary to access the vasculature for the injection of biologically active agents. Among the possible methods for accessing the mouse vasculature, tail vein injections are a routine but critical step for many experimental protocols. To perform successful tail vein injections, a high skill set and experience is required, leaving most scientists ill-suited to perform this task. This can lead to a high variability between injections, which can impact experimental results. To allow more scientists to perform tail vein injections and to decrease the variability between injections, a vascular access system (VAS) that semi-automatically inserts a needle into the tail vein of a mouse was developed. The VAS uses near infrared light, image processing techniques, computer controlled motors, and a pressure feedback system to insert the needle and to validate its proper placement within the vein. The VAS was tested by injecting a commonly used radiolabeled probe (FDG) into the tail veins of five mice. These mice were then imaged using micro-positron emission tomography to measure the percentage of the injected probe remaining in the tail. These studies showed that, on average, the VAS leaves 3.4% of the injected probe in the tail. With these preliminary results, the VAS system demonstrates the potential for improving the accuracy of tail vein injections in mice.
LED traffic signal management system : final report.
DOT National Transportation Integrated Search
2016-06-01
This research originated from the opportunity to develop a methodology to assess when LED (Light Emitting Diode) traffic signal modules begin to fail to meet the Institute of Transportation Engineers (ITE) performance specification for luminous inten...
Permeability of soil has become recognized as an important parameter in determining the rate of transport and entry of radon from the soil into indoor environments. This parameter is usually measured in the field by inserting a cylindrical tube with a short porous section into th...
Automatic cryogenic liquid level controller is safe for use near combustible substances
NASA Technical Reports Server (NTRS)
Krejsa, M.
1966-01-01
Automatic mechanical liquid level controller that is independent of any external power sources is used with safety in the presence of combustibles. A gas filled capillary tube which leads from a pressurized chamber, is inserted into the cryogenic liquid reservoir and becomes a liquid level sensing element or probe.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Sampling in the Administration of the Act § 201.40 Bulk. Bulk seeds or screenings shall be sampled by inserting a long probe or thrusting the hand into the bulk as circumstances require in at least seven... 7 Agriculture 3 2011-01-01 2011-01-01 false Bulk. 201.40 Section 201.40 Agriculture Regulations of...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Sampling in the Administration of the Act § 201.40 Bulk. Bulk seeds or screenings shall be sampled by inserting a long probe or thrusting the hand into the bulk as circumstances require in at least seven... 7 Agriculture 3 2010-01-01 2010-01-01 false Bulk. 201.40 Section 201.40 Agriculture Regulations of...
Manoonkitiwongsa, Panya S.; Wang, Cindy X.; McCreery, Douglas B.
2012-01-01
We developed and validated silicon-based neural probes for neural stimulating and recording in long-term implantation in the brain. The probes combine the deep reactive ion etching process and mechanical shaping of their tip region, yielding a mechanically sturdy shank with a sharpened tip to reduce insertion force into the brain and spinal cord, particularly, with multiple shanks in the same array. The arrays’ insertion forces have been quantified in vitro. Five consecutive chronically-implanted devices were fully functional from 3 to 18 months. The microelectrode sites were electroplated with iridium oxide, and the charge injection capacity measurements were performed both in vitro and after implantation in the adult feline brain. The functionality of the chronic array was validated by stimulating in the cochlear nucleus and recording the evoked neuronal activity in the central nucleus of the inferior colliculus. The arrays’ recording quality has also been quantified in vivo with neuronal spike activity recorded up to 566 days after implantation. Histopathology evaluation of neurons and astrocytes using immunohistochemical stains indicated minimal alterations of tissue architecture after chronic implantation. PMID:22020666
Automatic insertion of simulated microcalcification clusters in a software breast phantom
NASA Astrophysics Data System (ADS)
Shankla, Varsha; Pokrajac, David D.; Weinstein, Susan P.; DeLeo, Michael; Tuite, Catherine; Roth, Robyn; Conant, Emily F.; Maidment, Andrew D.; Bakic, Predrag R.
2014-03-01
An automated method has been developed to insert realistic clusters of simulated microcalcifications (MCs) into computer models of breast anatomy. This algorithm has been developed as part of a virtual clinical trial (VCT) software pipeline, which includes the simulation of breast anatomy, mechanical compression, image acquisition, image processing, display and interpretation. An automated insertion method has value in VCTs involving large numbers of images. The insertion method was designed to support various insertion placement strategies, governed by probability distribution functions (pdf). The pdf can be predicated on histological or biological models of tumor growth, or estimated from the locations of actual calcification clusters. To validate the automated insertion method, a 2-AFC observer study was designed to compare two placement strategies, undirected and directed. The undirected strategy could place a MC cluster anywhere within the phantom volume. The directed strategy placed MC clusters within fibroglandular tissue on the assumption that calcifications originate from epithelial breast tissue. Three radiologists were asked to select between two simulated phantom images, one from each placement strategy. Furthermore, questions were posed to probe the rationale behind the observer's selection. The radiologists found the resulting cluster placement to be realistic in 92% of cases, validating the automated insertion method. There was a significant preference for the cluster to be positioned on a background of adipose or mixed adipose/fibroglandular tissues. Based upon these results, this automated lesion placement method will be included in our VCT simulation pipeline.
High-Throughput Analysis of T-DNA Location and Structure Using Sequence Capture.
Inagaki, Soichi; Henry, Isabelle M; Lieberman, Meric C; Comai, Luca
2015-01-01
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA-genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously, using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. Our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tran, Ich C.; Tunuguntla, Ramya H.; Kim, Kyunghoon
Carbon nanotube porins (CNTPs), small segments of carbon nanotubes capable of forming defined pores in lipid membranes, are important future components for bionanoelectronic devices as they could provide a robust analog of biological membrane channels. Furthermore, in order to control the incorporation of these CNT channels into lipid bilayers, it is important to understand the structure of the CNTPs before and after insertion into the lipid bilayer as well as the impact of such insertion on the bilayer structure. Here we employed a noninvasive in situ probe, small-angle X-ray scattering, to study the integration of CNT porins into dioleoylphosphatidylcholine bilayers.more » These results show that CNTPs in solution are stabilized by a monolayer of lipid molecules wrapped around their outer surface. We also demonstrate that insertion of CNTPs into the lipid bilayer results in decreased bilayer thickness with the magnitude of this effect increasing with the concentration of CNTPs.« less
Phosphine-alkene ligands as mechanistic probes in the Pauson-Khand reaction.
Ferrer, Catalina; Benet-Buchholz, Jordi; Riera, Antoni; Verdaguer, Xavier
2010-07-26
An alkyne tetracarbonyl dicobalt complex with a chelated phosphine-alkene ligand, in which the phosphorus atom and the alkene from the ligand are attached to the same cobalt atom has been prepared, isolated, and characterized by X-ray crystallography. The complex serves as a mechanistic model for an intermediate of the Pauson-Khand (PK) reaction. Although the alkene fragment is located in an equatorial coordination site with an appropriate orientation, and, therefore, should undergo insertion, it failed to give the PK product upon either thermal or N-methylmorpholine N-oxide activation. However, a phosphine-alkene complex that contains a terminal alkene readily provided the corresponding PK product. We attribute this change in reactivity to the different ability of each olefin to undergo 1,2-insertion. These results provide further insights into the factors that govern a crucial step in the PK reaction, the olefin insertion.
Fu, Qiang; Tang, Jun; Cui, Meng; Xing, Junpeng; Liu, Zhiqiang; Liu, Shuying
2016-01-01
There is an increasing need for analyzing metabolism in a single cell, which is important to understand the nature of cellular heterogeneity, disease, growth and specialization, etc. However, single cell analysis is often challenging for the traces of samples. In the present study, porous metal enrichment probe sampling combined with matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS) has been applied for in situ analysis of live onion epidemic cell. Porous probe, treated by corroding copper wire with HCl, was directly inserted into a single cell to get cell solution. A self-made linear actuator was enough to control the penetration of probe into the target cell accurately. Then samples on the tip of probe were eluted and detected by a commercial MALDI-TOF-MS directly. The formation of porous microstructure on the probe surface increased the adsorptive capacity of cell solution. The sensitivity of porous probe sampling was 6 times higher than uncorroded probes generally. This method provides a sensitive and convenient way for the sampling and detection of single cell solution. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Ko, Woo Jin; Hruby, Gregory W; Turk, Andrew T; Landman, Jaime; Badani, Ketan K
2013-03-01
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Incremental nerve-sparing techniques (NSTs) improve postoperative erectile function after robot-assisted radical prostatectomy (RARP). However, there are no studies to date that histologically confirm the surgeon intended NST. Thus, in the present study, we histologically confirmed that the surgeon performed the nerve preservation as his intended NSTs during RARP. Also, we found that there was more variability in fascia width outcome on the left side compared with the right. Therefore, when performing nerve preservation on the surgeon's non-dominant side, we need to pay more close attention. To confirm that the surgeon achieved true intended histological nerve sparing during robot-assisted radical prostatectomy (RARP) by studying RP specimens. To aid the novice robotic surgeon to develop the skills of RARP. Between June 2008 and May 2009, 122 consecutive patients underwent RARP by a single surgeon (K.K.B.). The degree of nerve sparing (wide resection [WR], interfascial nerve sparing [ITE-NS], intrafascial nerve sparing [ITR-NS]) on both sides was recorded. The posterior sectors of RP specimens from distal, mid, and proximal parts were evaluated. Fascia width (FW) of each position in RP specimens were compared across nerve-sparing types (NSTs). FW was recorded at 15 ° intervals (3-9 o'clock position), measured as the distance between the outermost prostate gland and surgical margin. The slides were reviewed by an experienced uropathologist who was 'blinded' to the NST. In all, 93 men were included. The overall mean (sd) FW was the greatest in the order of WR, ITE-NS, and ITR-NS, at 2.42 (1.62), 1.71 (1.40) and 1.16 (1.08) mm, respectively (P < 0.001). FW was statistically significantly correlated with the surgical technique used. When the surgeon intended to perform various levels of nerve sparing, these were reflected in the FW. Interestingly, the left-side FW showed more variability than the right side. We suspect that this was a result of the surgeon's right-hand dominance. Erectile function (EF) recovery rate according to NST was 88.9%, 77.3%, 65.6%, 56.3%, and 0% in bilateral ITR-NS, ITR-NS/ITE-NS, bilateral ITE-NS, ITE-NS/WR, and bilateral WR, respectively. To further validate and confirm these preliminary findings, additional studies involving multicentre cohorts would be required. The surgeon intended dissection and FW correlate, with ITR-NS providing the narrowest FW and the EF recovery rate was the highest in bilateral ITR-NS. There was more variability in FW outcome on the left side than the right. The novice robotic surgeon should consider this variability when performing RARP. It may have implications for technique improvement on nerve preservation for EF. © 2012 BJU International.
Wu, Chin H; Grant, Christopher V; Cook, Gabriel A; Park, Sang Ho; Opella, Stanley J
2009-09-01
A strip-shield inserted between a high inductance double-tuned solenoid coil and the glass tube containing the sample improves the efficiency of probes used for high-field solid-state NMR experiments on lossy aqueous samples of proteins and other biopolymers. A strip-shield is a coil liner consisting of thin copper strips layered on a PTFE (polytetrafluoroethylene) insulator. With lossy samples, the shift in tuning frequency is smaller, the reduction in Q, and RF-induced heating are all significantly reduced when the strip-shield is present. The performance of 800MHz (1)H/(15)N and (1)H/(13)C double-resonance probes is demonstrated on aqueous samples of membrane proteins in phospholipid bilayers.
Electron density measurements in STPX plasmas
NASA Astrophysics Data System (ADS)
Clark, Jerry; Williams, R.; Titus, J. B.; Mezonlin, E. D.; Akpovo, C.; Thomas, E.
2017-10-01
Diagnostics have been installed to measure the electron density of Spheromak Turbulent Physics Experiment (STPX) plasmas at Florida A. & M. University. An insertable probe, provided by Auburn University, consisting of a combination of a triple-tipped Langmuir probe and a radial array consisting of three ion saturation current / floating potential rings has been installed to measure instantaneous plasma density, temperature and plasma potential. As the ramp-up of the experimental program commences, initial electron density measurements from the triple-probe show that the electron density is on the order of 1019 particles/m3. For a passive measurement, a CO2 interferometer system has been designed and installed for measuring line-averaged densities and to corroborate the Langmuir measurements. We describe the design, calibration, and performance of these diagnostic systems on large volume STPX plasmas.
UW Imaging of Seismic-Physical-Models in Air Using Fiber-Optic Fabry-Perot Interferometer.
Rong, Qiangzhou; Hao, Yongxin; Zhou, Ruixiang; Yin, Xunli; Shao, Zhihua; Liang, Lei; Qiao, Xueguang
2017-02-17
A fiber-optic Fabry-Perot interferometer (FPI) has been proposed and demonstrated for the ultrasound wave (UW) imaging of seismic-physical models. The sensor probe comprises a single mode fiber (SMF) that is inserted into a ceramic tube terminated by an ultra-thin gold film. The probe performs with an excellent UW sensitivity thanks to the nanolayer gold film, and thus is capable of detecting a weak UW in air medium. Furthermore, the compact sensor is a symmetrical structure so that it presents a good directionality in the UW detection. The spectral band-side filter technique is used for UW interrogation. After scanning the models using the sensing probe in air, the two-dimensional (2D) images of four physical models are reconstructed.
Fuel leak detection apparatus for gas cooled nuclear reactors
Burnette, Richard D.
1977-01-01
Apparatus is disclosed for detecting nuclear fuel leaks within nuclear power system reactors, such as high temperature gas cooled reactors. The apparatus includes a probe assembly that is inserted into the high temperature reactor coolant gaseous stream. The probe has an aperture adapted to communicate gaseous fluid between its inside and outside surfaces and also contains an inner tube for sampling gaseous fluid present near the aperture. A high pressure supply of noncontaminated gas is provided to selectively balance the pressure of the stream being sampled to prevent gas from entering the probe through the aperture. The apparatus includes valves that are operable to cause various directional flows and pressures, which valves are located outside of the reactor walls to permit maintenance work and the like to be performed without shutting down the reactor.
Conformational Dynamics inside Amino-Terminal Disease Hotspot of Ryanodine Receptor
Zhong, Xiaowei; Liu, Ying; Zhu, Li; Meng, Xing; Wang, Ruiwu; Van Petegem, Filip; Wagenknecht, Terence; Wayne Chen, S. R.; Liu, Zheng
2013-01-01
Summary The N-terminal region of both skeletal and cardiac ryanodine receptor is a disease mutation hotspot. Recently, a crystal structure of the RyR1 fragment (residues 1-559) was solved. This N-terminal structure contains three separate domains, A, B, and C, and was docked into a central vestibule in a full-length RyR1 cryo-EM map. Here we reconstructed 3D cryo-EM structures of two GFP-tagged RyR2s with GFP inserted after residue Glu-310 and Ser-437, respectively. The structures of RyR2E310-GFP and RyR2S437-GFP displayed an extra mass on domain B and C, directly validating the predicted docking model. Next, we revealed domain movements in molecular dynamics flexible fitting models in both the closed and open state cryo-EM maps. To further probe the conformational changes, we generated FRET pairs by inserting CFP or YFP in two selected domains, FRET studies of three dual-insertion pairs and three co-expressed single-insertion pairs showed the dynamic structural changes within the N-terminal domains. PMID:24139989
Trip generation studies for special generators : final report, December 2009.
DOT National Transportation Integrated Search
2009-09-01
This research examines the effects of town centers and senior housing developments on surrounding roadways and nearby transit. The Institute of Transportation Engineers (ITE) Trip Generation Manual, which determines number of trips produced or attrac...
NASA Astrophysics Data System (ADS)
Katura, Takusige; Tanaka, Naoki; Obata, Akiko; Sato, Hiroki; Maki, Atsushi
2005-08-01
In this study, from the information-theoretic viewpoint, we analyzed the interrelation between the spontaneous low-frequency fluctuations around 0.1Hz in the hemoglobin concentration in the cerebral cortex, mean arterial blood pressure and the heart rate. For this analysis, as measures of information transfer, we used transfer entropy (TE) proposed for two-factor systems by Schreiber and intrinsic transfer entropy (ITE) introduced for further analysis of three-factor systems by extending the original TE. In our analysis, information transfer analysis based on both TE and ITE suggests the systemic cardiovascular fluctuations alone cannot account for the cerebrovascular fluctuations, that is, the regulation of the regional cerebral energetic metabolism is important as a candidate of its generation mechanism Such an information transfer analysis seems useful to reveal the interrelation between the elements regulated each other in a complex manner.
NASA Technical Reports Server (NTRS)
Koenig, S. C.; Ludwig, D. A.; Reister, C.; Fanton, J. W.; Ewert, D.; Convertino, V. A.
2001-01-01
Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.
NASA Astrophysics Data System (ADS)
Yamada, M.; Ren, Y.; Ji, H.; Gerhardt, S.; Darfman, S.
2006-12-01
With the recent upgrade of the MRX (Magnetic Reconnection Experiment) device[1], our experimental operation allows us to carry out a jog experiment in which a current sheet can be moved swiftly across an inserted probe assembly. A cluster of probes with variable distances can be inserted into a known desired position in the MRX device. This setup can be similar to the situation in which a cluster of satellites encounters a rapidly moving reconnection layer. If necessary, we can create a neutral sheet where the density of one side is significantly higher than the other, as is the case for the magnetopause. A variable guide field will be applied to study its effect on reconnection. We proposed[2] to document basic patterns of data during a simulated encounter of the MRX reconnection layer with the four-probe mock-up system and compare them with data acquired from past satellites. Relative position of the MMS satellites in the magnetosphere can then be determined. Optimum cluster configuration or distance between the four satellites can be determined for various diagnostics or research missions. The relationship of magnetic fluctuations[3] with the observed out-of- plane quadrupole field, a characteristic signature of the Hall MHD, can be also studied in this series of experiments. In this paper, results from a preliminary experiment will be presented. These experiments utilize effectively the unique MRX ability to accurately know the location of diagnostics with respect to the moving reconnection layer. Supported by DoE, NASA, NSF. [1] M. Yamada et al, Phys. Plasmas 13, 052119 (2006), [2] M.Yamada et al, MMS-IDS proposal (2006), [3] H. Ji et al, Phys. Rev. Letts. 92, 115001 (2004)
NASA Astrophysics Data System (ADS)
Schwarz, France; Le Nevez, Arnaud; Genet, Magalie; Osdoit, Anne; Lacombe, François
2009-02-01
Background: Confocal Laser Endomicroscopy (CLE) based on ultraminiature miniprobes (Cellvizio®, Mauna Kea Technologies, Paris, France) is able to image the inner microstructure of retroperitoneal full organs punctured during EUS-FNA procedures, such as pancreas, liver or lymph nodes. Therefore, pCLE can provide an easy-to-use and precise adjunct tool to ultrasonographic interventions in order to target suspicious areas for biopsies in EUS-FNA. Material and Methods: Probe-based CLE (pCLE) was performed on ex-vivo surgically resected specimens after topical application of fluorophores in standard 19G and 22G needles. Two prototype miniprobes ("S-probe" 300 microns diameter, field of view 400*280 microns, and "S-probe" 650 microns diameter, field of view 500*600 microns) were then inserted into the needles and enabled visualization of the inner microstructures of uterus, lung, kidney, stomach and esophagus, in both healthy and cancerous conditions. Then, pCLE was performed in-vivo on four pigs during three NOTES and one EUS-FNA procedures after intravenous injection of 2-7mL fluorescein 1-10% using the prototype "S-probe" 350 microns diameter inserted in 19G FNA needles. Liver, pancreas and spleen were imaged. Results: During the ex-vivo experiments, pCLE made it possible to distinguish microstructures, such as alveoli and macrophages in the lungs. During the in-vivo experiments, Cellvizio® video sequences showed hepatic lobules and the portal vein in the liver, and red and white pulp in the spleen. Conclusion: pCLE provides in vivo cellular information about full organs. It has the potential to help target biopsies during EUSFNA, which suffers from a high rate of false negatives, thus increasing its sensitivity.
Intensive Exercise Training During Bed Rest Attenuates Deconditioning
NASA Technical Reports Server (NTRS)
Greenleaf, John E.
1997-01-01
Intensive exercise training during bed rest attenuates deconditioning. Med. Sci. Sports Exerc., Vol. 29, No. 2, pp. 207-215, 1997. A 30-d 6 deg head-down bed rest project was conducted to evaluate variable high-intensity, short-duration, isotonic cycle ergometer exercise (ITE) training and high-intensity intermittent resistive isokinetic exercise (IKE) training regimens designed to maintain peak VO2 and muscle mass, strength, and endurance at ambulatory control levels throughout prolonged bed rest. Other elements of the deconditioning (adaptive) syndrome, such as proprioception, psychological performance, hypovolemia, water balance, body composition, and orthostatic tolerance, were also measured. Major findings are summarized in this paper. Compared with response during bed rest of the no exercise (NOE) control group: the ITE training regimen (a) maintained work capacity (peak VO2), (b) maintained plasma and red cell volumes, (c) induced positive body water balance, (d) decreased quality of sleep and mental concentration, and (e) had no effect on the decrease in orthostatic tolerance; the IKE training regimen (f) attenuated the decrease in peak VO2 by 50%, (g) attenuated loss of red cell volume by 40% but had no effect on loss of plasma volume, (b) induced positive body water balance, (i) had no adverse effect on quality of sleep or concentration, and 0) had no effect on the decrease in orthostatic tolerance. These findings suggest that various elements of the deconditioning syndrome can be manipulated by duration and intensity of ITE or IKE training regimens and that several different training protocols will be required to maintain or restore physiological and psychological performance of individuals confined to prolonged bed rest.
Tavarez, Melissa M; Kenkre, Tanya S; Zuckerbraun, Noel
2017-05-30
The aim of this study was to determine if implementation of our evidence-based medicine (EBM) curriculum had an effect on pediatric emergency medicine fellows' scores on the relevant section of the in-training examination (ITE). We obtained deidentified subscores for 22 fellows over 6 academic years for the Core Knowledge in Scholarly Activities (SA) and, as a balance measure, Emergencies Treated Medically sections. We divided the subscores into the following 3 instruction periods: "baseline" for academic years before our current EBM curriculum, "transition" for academic years with use of a research method curriculum with some overlapping EBM content, and "EBM" for academic years with our current EBM curriculum. We analyzed data using the Kruskal-Wallis test, the Mann-Whitney U test, and multivariate mixed-effects linear models. The SA subscore median was higher during the EBM period in comparison with the baseline and transition periods. In contrast, the Emergencies Treated Medically subscore median was similar across instruction periods. Multivariate modeling demonstrated that our EBM curriculum had the following independent effects on the fellows' SA subscore: (1) in comparison with the transition period, the fellows' SA subscore was 21 percentage points higher (P = 0.005); and (2) in comparison to the baseline period, the fellows' SA subscore was 28 percentage points higher during the EBM curriculum instruction period (P < 0.001). Our EBM curriculum was associated with significantly higher scores on the SA section of the ITE. Pediatric emergency medicine educators could consider using fellows' scores on this section of the ITE to assess the effect of their EBM curricula.
Mainous, Arch G; Fang, Bo; Peterson, Lars E
2017-12-01
The Family Medicine (FM) Milestones are competency-based assessments of residents in key dimensions relevant to practice in the specialty. Residency programs use the milestones in semiannual reviews of resident performance from the time of entry into the program to graduation. Using a national sample, we investigated the relationship of FM competency-based assessments to resident progress and the complementarity of milestones with knowledge-based assessments in FM residencies. We used midyear and end-of-year milestone ratings for all FM residents in Accreditation Council for Graduate Medical Education-accredited programs during academic years 2014-2015 and 2015-2016. The milestones contain 22 items across 6 competencies. We created a summative index across the milestones. The American Board of Family Medicine database provided resident demographics and in-training examination (ITE) scores. We linked information to the milestone data. The sample encompassed 6630 FM residents. The summative milestone index increased, on average, for each cohort (postgraduate year 1 [PGY-1] to PGY-2 and PGY-2 to PGY-3) at each assessment. The correlation between the milestone index that excluded the medical knowledge milestone and ITE scores was r = .195 ( P < .001) for PGY-1 to PGY-2 cohort and r = .254 ( P < .001) for PGY-2 to PGY-3 cohort. For both cohorts, ITE scores and composite milestone assessments were higher for residents who advanced than for those who did not. Competency-based assessment using the milestones for FM residents seems to be a viable multidimensional tool to assess the successful progression of residents.
NASA Technical Reports Server (NTRS)
Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.
1994-01-01
To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.
Bernauer, E M; Walby, W F; Ertl, A C; Dempster, P T; Bond, M; Greenleaf, J E
1994-12-01
To determine if daily isotonic exercise or isokinetic exercise training coupled with daily leg proprioceptive training, would influence leg proprioceptive tracking responses during bed rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a no-exercise (NOE) training control group (n = 5), and isotonic exercise (ITE, n = 7) and isokinetic exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min periods.d-1, 5 d.week-1. Only the IKE group performed proprioceptive training using a new isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pre-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p < 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9* +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.5%, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both isotonic exercise training (without additional proprioceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.
NASA Technical Reports Server (NTRS)
Bernauer, E. M.; Walby, W. F.; Ertl, A. C.; Dempster, P. T.; Bond, M.; Greenleaf, J. E.
1994-01-01
To determine if daily isotonic exercise or isokinetic exercise training coupled with daily log proprioceptive training, would influence log proprioceptive tracking responses during Bed Rest (BR), 19 men (36 +/- SD 4 years, 178 +/- 7 cm, 76.8 +/- 7.8 kg) were allocated into a NO-Exercise (NOE) training control group (n = 5), and IsoTanic Exercise (ITE, n = 7) and IsoKinetic Exercise (IKE, n = 7) training groups. Exercise training was conducted during BR for two 30-min period / d, 5 d /week. Only the IKE group performed proprioceptive training using a now isokinetic procedure with each lower extremity for 2.5 min before and after the daily exercise training sessions; proprioceptive testing occurred weekly for all groups. There were no significant differences in proprioceptive tracking scores, expressed as a percentage of the perfect score of 100, in the pro-BR ambulatory control period between the three groups. Knee extension and flexion tracking responses were unchanged with NOE during BR, but were significantly greater (*p less than 0.05) at the end of BR in both exercise groups when compared with NOE responses (extension: NOE 80.7 +/- 0.7%, ITE 82.9 +/- 0.6%, IKE 86.5* +/- 0.7%; flexion: NOE 77.6 +/- 1.50, ITE 80.0 +/- 0.8% (NS), IKE 83.6* +/- 0.8%). Although proprioceptive tracking was unchanged during BR with NOE, both lsotonic exercise training (without additional propriaceptive training) and especially isokinetic exercise training when combined with daily proprioceptive training, significantly improved knee proprioceptive tracking responses after 30 d of BR.
CONTAMINANTS AND REMEDIAL OPTIONS AT PESTICIDE SITES
Many types of soils, sediments, and sludges are contaminated with a wide variety of pesticides. ite-specific characteristics such as volume to be treated, extent of contamination, and applicable cleanup goals differ greatly, and contaminant toxicity, migration pathways, persisten...
HYDROCARBON SPILL EXPOSURE ASSESSMENT MODELING
Hydrocarbon spills impact drinking water supplies at down gradient locations. onventional finite difference and finite element models of multiphase, multicomponent flow have extreme requirements for both computer time and site data. ite data and the intent of the modeling often d...
NASA Astrophysics Data System (ADS)
Aguiar-González, Borja; Ponsoni, Leandro; Ridderinkhof, Herman; de Ruijter, Will P. M.; Maas, Leo R. M.
2016-04-01
The South East Madagascar Current (SEMC) flows poleward along the eastern coast of Madagascar as a western boundary current which further south provides some of the source waters of the Agulhas Current, either directly or in the form of eddies. We investigate the region of dipole formation south of Madagascar combining vertical T/S profiles from Argo floats, altimetry measurements and an existing eddy detection algorithm. Results from our analysis show that the dipole consists of an anticyclonic intrathermocline eddy (ITE) formed on its southern flank and a cyclonic ITE formed on its northern flank. Both lobes of the dipole exhibit similar T/S properties throughout the water column, although vertically shifted within the thermocline depending on its nature: upward in a cyclonic ITE and downward in an anticyclonic ITE. A subsurface salinity maximum of about 35.5 psu characterizes the upper layers with Subtropical Surface Water (STSW). At intermediate levels, a well defined path of South Indian Central Water (SICW) extends throughout the water column up to reach a minimum in salinity of 34.5 psu, corresponding to Antarctic Intermediate Water (AAIW). Below, at deep layers, the North Atlantic Deep Water (NADW) is found. The intrathermocline nature of the Madagascar dipoles has not been previously reported and represents an important feature to be considered when assessing the heat and salt fluxes driven by eddy movement and contributing to the Agulhas Current. Unlike surface eddies, intrathermocline eddies strongly influence the intermediate/deeper layers in the oceans and, hence, may have a larger contribution in the spreading rates and pathways of water masses. Because the intrathermocline nature of eddies is invisible to altimetry measurements, these results stress the importance of combining altimetry with historical records of Argo profiles which uncover eddy dynamics below the sea surface. Lastly, we further investigate from altimetry the area of dipole formation. The main axis of the SEMC appears flanked on its northern and southern borders by a semi-isolated semicircular region where kinetic energy of the mean flow is being transfered to the eddy kinetic energy field, in this case to the dipole formation, through barotropic instabilities without the need of an evident SEMC retroflection. In this regard, future work will be addressed to account for the mechanism by which Madagascar dipoles thus generated present an intrathermocline structure.
Noncontact Measurement Of Critical Current In Superconductor
NASA Technical Reports Server (NTRS)
Israelsson, Ulf E.; Strayer, Donald M.
1992-01-01
Critical current measured indirectly via flux-compression technique. Magnetic flux compressed into gap between superconductive hollow cylinder and superconductive rod when rod inserted in hole in cylinder. Hall-effect probe measures flux density before and after compression. Method does not involve any electrical contact with superconductor. Therefore, does not cause resistive heating and consequent premature loss of superconductivity.
Krasheninina, Olga A; Novopashina, Darya S; Lomzov, Alexander A; Venyaminova, Alya G
2014-09-05
The synthesis and properties two series of new 2'-O-methyl RNA probes, each containing a single insertion of a 2'-bispyrenylmethylphosphorodiamidate derivative of a nucleotide (U, C, A, and G), are described. As demonstrated by UV melting studies, the probes form stable complexes with model RNAs and DNAs. Significant increases (up to 21-fold) in pyrene excimer fluorescence intensity were observed upon binding of most of the probes with complementary RNAs, but not with DNAs. The fluorescence spectra are independent of the nature of the modified nucleotides. The nucleotides on the 5'-side of the modified nucleotide have no effect on the fluorescence spectra, whereas the natures of the two nucleotides on the 3'-side are important: CC, CG, and UC dinucleotide units on the 3'-side of the modified nucleotide provide the maximum increases in excimer fluorescence intensity. This study suggests that these 2'-bispyrene-labeled 2'-O-methyl RNA probes might be useful tools for detection of RNAs. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mannelli, Ilaria; Minunni, Maria; Tombelli, Sara; Mascini, Marco
2003-03-01
A DNA piezoelectric sensor has been developed for the detection of genetically modified organisms (GMOs). Single stranded DNA (ssDNA) probes were immobilised on the sensor surface of a quartz crystal microbalance (QCM) device and the hybridisation between the immobilised probe and the target complementary sequence in solution was monitored. The probe sequences were internal to the sequence of the 35S promoter (P) and Nos terminator (T), which are inserted sequences in the genome of GMOs regulating the transgene expression. Two different probe immobilisation procedures were applied: (a) a thiol-dextran procedure and (b) a thiol-derivatised probe and blocking thiol procedure. The system has been optimised using synthetic oligonucleotides, which were then applied to samples of plasmidic and genomic DNA isolated from the pBI121 plasmid, certified reference materials (CRM), and real samples amplified by the polymerase chain reaction (PCR). The analytical parameters of the sensor have been investigated (sensitivity, reproducibility, lifetime etc.). The results obtained showed that both immobilisation procedures enabled sensitive and specific detection of GMOs, providing a useful tool for screening analysis in food samples.
NASA Technical Reports Server (NTRS)
Dhadwal, Harbans S. (Inventor)
1992-01-01
A system for determining the physical properties of materials through the use of dynamic light scattering is disclosed. The system includes a probe, a laser source for directing a laser beam into the probe, and a photodetector for converting scattered light detected by the probe into electrical signals. The probe includes at least one optical fiber connected to the laser source and a second optical fiber connected to the photodetector. Each of the fibers may adjoin a gradient index microlens which is capable of providing a collimated laser beam into a scattering medium. The position of the second optical fiber with respect to the optical axis of the probe determines whether homodyne or self-beating detection is provided. Self-beating detection may be provided without a gradient index microlens. This allows a very small probe to be constructed which is insertable through a hypodermic needle or the like into a droplet extending from such a needle. A method of detecting scattered light through the use of a collimated, Gaussian laser beam is also provided. A method for controlling the waist and divergence of the optical field emanating from the free end of an optical fiber is also provided.
Dixon, Daniel; Darden, Bruce; Casamitjana, Jose; Weissmann, Karen A; Cristobal, San; Powell, David; Baluch, Daniel
2017-04-01
A fresh frozen cadaver study was conducted. To report the cortical breach rate using the dynamic surgical guidance (DSG) probe versus traditional freehand technique for cervical lateral mass, cervical pedicle and cervical laminar screws. Nine male fresh frozen cadaveric torsos were utilized for this study. Each investigator was assigned three specimens that were randomized by fixation point, side and order of technique for establishing a screw pilot hole. The technique for screw hole preparation utilized was either a DSG probe in the "on" mode or in the "off" mode using a freehand technique popularized by Lenke et al. Levels instrumented included C1 lateral mass, C2 pedicle screws and lamina screws, and C6-T1 pedicle screws. Fluoroscopy and other navigational assistance were not used for screw hole preparation or screw insertion. All specimens were CT imaged following insertion of all screws. A senior radiologist evaluated all scans and determined that a misplaced screw was a breach of ≥2 mm. A total of 104 drillings were performed, 52 with DSG and 52 without DSG There were 68 total pedicle drillings, 34 in each group. There were 18 drillings in the lamina and lateral mass. There was no significant difference between surgeons or between the left and right side. All breaches were in the pedicle, and none in the lamina or lateral mass. The breach rate for PG "on" was 6/68 = 8.96% (95% CI 3.69, 19.12%). The breach rate for PG "off" was 20/68 = 29.41% (95% CI 19.30, 41.87%). Of the 20 pedicle breaches in the non-DSG group, 7 were lateral and superior, 8 were lateral, 4 medial and 1 inferior. Of the six pedicle breaches in the DSG group, two were lateral/superior, two were lateral and two were medial in the pedicle. The dynamic surgical guidance probe is a safe tool to assist the surgeon with screw placement in the cervical spine. Additionally, the DSG potentially avoids the cumulative risks associated with fluoroscopy and provides real-time feedback to the surgeon allowing correction at the time of breach. Level of evidence Level IV.
Determination of Surface-Exposed, Functional Domains of Gonococcal Transferrin-Binding Protein A
Yost-Daljev, Mary Kate; Cornelissen, Cynthia Nau
2004-01-01
The gonococcal transferrin receptor is composed of two distinct proteins, TbpA and TbpB. TbpA is a member of the TonB-dependent family of integral outer membrane transporters, while TbpB is lipid modified and thought to be peripherally surface exposed. We previously proposed a hypothetical topology model for gonococcal TbpA that was based upon computer predictions and similarity with other TonB-dependent transporters for which crystal structures have been determined. In the present study, the hemagglutinin epitope was inserted into TbpA to probe the surface topology of this protein and secondarily to test the functional impacts of site-specific mutagenesis. Twelve epitope insertion mutants were constructed, five of which allowed us to confirm the surface exposure of loops 2, 3, 5, 7, and 10. In contrast to the predictions set forth by the hypothetical model, insertion into the plug region resulted in an epitope that was surface accessible, while epitope insertions into two putative loops (9 and 11) were not surface accessible. Insertions into putative loop 3 and β strand 9 abolished transferrin binding and utilization, and the plug insertion mutant exhibited decreased transferrin-binding affinity concomitant with an inability to utilize it. Insertion into putative β strand 16 generated a mutant that was able to bind transferrin normally but that was unable to mediate utilization. Mutants with insertions into putative loops 2, 9, and 11 maintained wild-type binding affinity but could utilize only transferrin in the presence of TbpB. This is the first demonstration of the ability of TbpB to compensate for a mutation in TbpA. PMID:14977987
Discrepancy between culture and DNA probe analysis for the detection of periodontal bacteria.
van Steenbergen, T J; Timmerman, M F; Mikx, F H; de Quincey, G; van der Weijden, G A; van der Velden, U; de Graaff, J
1996-10-01
The purpose of this study was to compare a commercially available DNA probe technique with conventional cultural techniques for the detection of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia in subgingival plaque samples. Samples from 20 patients with moderate to severe periodontitis were evaluated at baseline and during a 15 months period of periodontal treatment. Paperpoints from 4 periodontal pockets per patient were forwarded to Omnigene for DNA probe analysis, and simultaneously inserted paperpoints from the same pockets were analyzed by standard culture techniques. In addition, mixed bacterial samples were constructed harbouring known proportions of 25 strains of A. actinomycetemcomitans, P. gingivalis and P. intermedia each. A relatively low concordance was found between both methods. At baseline a higher detection frequency was found for A. actinomycetemcomitans and P. gingivalis for the DNA probe technique; for P. intermedia the detection frequency by culture was higher. For A. actinomycetemcomitans, 21% of the culture positive samples was positive with the DNA probe. Testing the constructed bacterial samples with the DNA probe method resulted in about 16% false positive results for the 3 species tested. Furthermore, 40% of P. gingivalis strains were not detected by the DNA probe. The present data suggest that at least part of the discrepancies found between the DNA probe technique used and cultural methods are caused by false positive and false negative DNA probe results. Therefore, the value of this DNA probe method for the detection of periodontal pathogens is questionable.
Song, Shi-Lin
2013-04-01
To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.
Tube cutter tool and method of use for coupon removal
Nachbar, H.D.; Etten, M.P. Jr.; Kurowski, P.A.
1997-05-06
A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place. 4 figs.
Tube cutter tool and method of use for coupon removal
Nachbar, Henry D.; Etten, Jr., Marvin P.; Kurowski, Paul A.
1997-01-01
A tube cutter tool is insertable into a tube for cutting a coupon from a damaged site on the exterior of the tube. Prior to using the tool, the damaged site is first located from the interior of the tube using a multi-coil pancake eddy current test probe. The damaged site is then marked. A fiber optic probe is used to monitor the subsequent cutting procedure which is performed using a hole saw mounted on the tube cutter tool. Prior to completion of the cutting procedure, a drill in the center of the hole saw is drilled into the coupon to hold it in place.
Galileo Jupiter approach orbit determination
NASA Technical Reports Server (NTRS)
Miller, J. K.; Nicholson, F. T.
1984-01-01
Orbit determination characteristics of the Jupiter approach phase of the Galileo mission are described. Predicted orbit determination performance is given for the various mission events that occur during Jupiter approach. These mission events include delivery of an atmospheric entry probe, acquisition of probe science data by the Galileo orbiter for relay to earth, delivery of an orbiter to a close encounter of the Galilean satellite Io, and insertion of the orbiter into orbit about Jupiter. The orbit determination strategy and resulting accuracies are discussed for the data types which include Doppler, range, optical imaging of Io, and a new Very Long Baseline Interferometry (VLBI) data type called Differential One-Way Range (DOR).
High-throughput analysis of T-DNA location and structure using sequence capture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inagaki, Soichi; Henry, Isabelle M.; Lieberman, Meric C.
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA—genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously,more » using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. As a result, our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.« less
High-throughput analysis of T-DNA location and structure using sequence capture
Inagaki, Soichi; Henry, Isabelle M.; Lieberman, Meric C.; ...
2015-10-07
Agrobacterium-mediated transformation of plants with T-DNA is used both to introduce transgenes and for mutagenesis. Conventional approaches used to identify the genomic location and the structure of the inserted T-DNA are laborious and high-throughput methods using next-generation sequencing are being developed to address these problems. Here, we present a cost-effective approach that uses sequence capture targeted to the T-DNA borders to select genomic DNA fragments containing T-DNA—genome junctions, followed by Illumina sequencing to determine the location and junction structure of T-DNA insertions. Multiple probes can be mixed so that transgenic lines transformed with different T-DNA types can be processed simultaneously,more » using a simple, index-based pooling approach. We also developed a simple bioinformatic tool to find sequence read pairs that span the junction between the genome and T-DNA or any foreign DNA. We analyzed 29 transgenic lines of Arabidopsis thaliana, each containing inserts from 4 different T-DNA vectors. We determined the location of T-DNA insertions in 22 lines, 4 of which carried multiple insertion sites. Additionally, our analysis uncovered a high frequency of unconventional and complex T-DNA insertions, highlighting the needs for high-throughput methods for T-DNA localization and structural characterization. Transgene insertion events have to be fully characterized prior to use as commercial products. As a result, our method greatly facilitates the first step of this characterization of transgenic plants by providing an efficient screen for the selection of promising lines.« less
Optimizing the specificity of nucleic acid hybridization
Zhang, David Yu; Chen, Sherry Xi; Yin, Peng
2014-01-01
The specific hybridization of complementary sequences is an essential property of nucleic acids, enabling diverse biological and biotechnological reactions and functions. However, the specificity of nucleic acid hybridization is compromised for long strands, except near the melting temperature. Here, we analytically derived the thermodynamic properties of a hybridization probe that would enable near-optimal single-base discrimination and perform robustly across diverse temperature, salt and concentration conditions. We rationally designed ‘toehold exchange’ probes that approximate these properties, and comprehensively tested them against five different DNA targets and 55 spurious analogues with energetically representative single-base changes (replacements, deletions and insertions). These probes produced discrimination factors between 3 and 100+ (median, 26). Without retuning, our probes function robustly from 10 °C to 37 °C, from 1 mM Mg2+ to 47 mM Mg2+, and with nucleic acid concentrations from 1 nM to 5 μM. Experiments with RNA also showed effective single-base change discrimination. PMID:22354435
Akahori, Rena; Yanagi, Itaru; Goto, Yusuke; Harada, Kunio; Yokoi, Takahide; Takeda, Ken-Ichi
2017-08-22
To achieve DNA sequencing with solid-state nanopores, the speed of the DNA in the nanopore must be controlled to obtain sequence-specific signals. In this study, we fabricated a nanopore-sensing system equipped with a DNA motion controller. DNA strands were immobilized on a Si probe, and approach of this probe to the nanopore vicinity could be controlled using a piezo actuator and stepper motor. The area of the Si probe was larger than the area of the membrane, which meant that the immobilized DNA could enter the nanopore without the need for the probe to scan to determine the location of the nanopore in the membrane. We demonstrated that a single-stranded DNA could be inserted into and removed from a nanopore in our experimental system. The number of different ionic-current levels observed while DNA remained in the nanopore corresponded to the number of different types of homopolymers in the DNA.
Contoured Surface Eddy Current Inspection System
Batzinger, Thomas James; Fulton, James Paul; Rose, Curtis Wayne; Perocchi, Lee Cranford
2003-04-08
Eddy current inspection of a contoured surface of a workpiece is performed by forming a backing piece of flexible, resiliently yieldable material with a contoured exterior surface conforming in shape to the workpiece contoured surface. The backing piece is preferably cast in place so as to conform to the workpiece contoured surface. A flexible eddy current array probe is attached to the contoured exterior surface of the backing piece such that the probe faces the contoured surface of the workpiece to be inspected when the backing piece is disposed adjacent to the workpiece. The backing piece is then expanded volumetrically by inserting at least one shim into a slot in the backing piece to provide sufficient contact pressure between the probe and the workpiece contoured surface to enable the inspection of the workpiece contoured surface to be performed.
Dose verification of eye plaque brachytherapy using spectroscopic dosimetry.
Jarema, T; Cutajar, D; Weaver, M; Petasecca, M; Lerch, M; Kejda, A; Rosenfeld, A
2016-09-01
Eye plaque brachytherapy has been developed and refined for the last 80 years, demonstrating effective results in the treatment of ocular malignancies. Current dosimetry techniques for eye plaque brachytherapy (such as TLD- and film-based techniques) are time consuming and cannot be used prior to treatment in a sterile environment. The measurement of the expected dose distribution within the eye, prior to insertion within the clinical setting, would be advantageous, as any errors in source loading will lead to an erroneous dose distribution and inferior treatment outcomes. This study investigated the use of spectroscopic dosimetry techniques for real-time quality assurance of I-125 based eye plaques, immediately prior to insertion. A silicon detector based probe, operating in spectroscopy mode was constructed, containing a small (1 mm(3)) silicon detector, mounted within a ceramic holder, all encapsulated within a rubber sheath to prevent water infiltration of the electronics. Preliminary tests of the prototype demonstrated that the depth dose distribution through the central axis of an I-125 based eye plaque may be determined from AAPM Task Group 43 recommendations to a deviation of 6 % at 3 mm depth, 7 % at 5 mm depth, 1 % at 10 mm depth and 13 % at 20 mm depth, with the deviations attributed to the construction of the probe. A new probe design aims to reduce these discrepancies, however the concept of spectroscopic dosimetry shows great promise for use in eye plaque quality assurance in the clinical setting.
CHRIS: Hazardous Chemical Data
1978-10-01
CPLORD-O-TOLUICIfE FAST RED Z& BASE = ’-1-ITRCAMILINE FERMENTAITION ALCOH!OL - ETHYL ALCOHOL FERMENTATION AMYL ALCOHCL -ISCANYL ALCOJIGI FERMENTATION BUTYL...ACID ETHYLENEDIAMINE IETRACETIC ACID VIC-H-XYLENOL XYLENOL VIENNA GREEN COPPER ACETOARSE1ITE VILRATHANE 4300 -CIPHENYLETHAME01ISOCYANATE (MDIl VINEGAR
NASA Technical Reports Server (NTRS)
Jolliff, Bradley L.; Rockow, Kaylynn M.; Korotev, Randy L.; Haskin, Larry A.
1996-01-01
Through analysis by instrumental neutron activation (INAA) of 789 individual lithic fragments from the 2 mm-4 mm grain-size fractions of five Apollo 17 soil samples (72443, 72503, 73243, 76283, and 76503) and petrographic examination of a subset, we have determined the diversity and proportions of rock types recorded within soils from the highland massifs. The distribution of rock types at the site, as recorded by lithic fragments in the soils, is an alternative to the distribution inferred from the limited number of large rock samples. The compositions and proportions of 2 mm-4 mm fragments provide a bridge between compositions of less than 1 mm fines and types and proportions of rocks observed in large collected breccias and their clasts. The 2 mm-4 mm fraction of soil from South Massif, represented by an unbiased set of lithic fragments from station-2 samples 72443 and 72503, consists of 71% noritic impact-melt breccia, 7% Incompatible-Trace-Element-(ITE)-poor highland rock types (mainly granulitic breccias), 19% agglutinates and regolith breccias, 1% high-Ti mare basalt, and 2% others (very-low-Ti (VLT) basalt, monzogabbro breccia, and metal). In contrast, the 2 mm - 4 mm fraction of a soil from the North Massif, represented by an unbiased set of lithic fragments from station-6 sample 76503, has a greater proportion of ITE-poor highland rock types and mare-basalt fragments: it consists of 29% ITE-poor highland rock types (mainly granulitic breccias and troctolitic anorthosite), 25% impact-melt breccia, 13% high-Ti mare basalt, 31 % agglutinates and regolith breccias, 1% orange glass and related breccia, and 1% others. Based on a comparison of mass- weighted mean compositions of the lithic fragments with compositions of soil fines from all Apollo 17 highland stations, differences between the station-2 and station-6 samples are representative of differences between available samples from the two massifs. From the distribution of different rock types and their compositions, we conclude the following: (1) North-Massif and South-Massif soil samples differ significantly in types and proportions of ITE-poor highland components and ITE-rich impact-melt-breccia components. These differences reflect crudely layered massifs and known local geology. The greater percentage of impact-melt breccia in the South- Massif light-mantle soil stems from derivation of the light mantle from the top of the massif, which apparently is richer in noritic impact-melt breccia than are lower parts of the massifs. (2) At station 2, the 2 mm-4 mm grain-size fraction is enriched in impact-melt breccias compared to the less than 1 mm fraction, suggesting that the <1 mm fraction within the light mantle has a greater proportion of lithologies such as granulitic breccias which are more prevalent lower in the massifs and which we infer to be older (pre-basin) highland components. (3) Soil from station 6, North Massif, contains magnesian troctolitic anorthosite, which is a component that is rare in station-2 South-Massif,contains magnesian troctolitic in impact-melt breccia interpreted by most investigators to be ejecta from the Serenitatis basin.
Use of a fiberscope for examining cavity nests
Kathryn L. Purcell
1997-01-01
A system is described that uses a fiberscope to view nests in cavities to provide detailed information on eggs and nestlings. The flexible probe can be inserted around bends, and the tip articulates to allow viewing of the entire cavity and nest. A light guide bundle furnishes light to enable viewing of dark cavities and optical fibers transmit the impage from the lens...
Trip attraction rates of shopping centers in Northern New Castle County, Delaware.
DOT National Transportation Integrated Search
2004-07-01
This report presents the trip attraction rates of the shopping centers in Northern New : Castle County in Delaware. The study aims to provide an alternative to ITE Trip : Generation Manual (1997) for computing the trip attraction of shopping centers ...
ITE CHARACTERIZATION TO SUPPORT CONCEPTUAL MODEL DEVELOPMENT FOR SUBSURFACE RADIONUCLIDE TRANSPORT
Remediation of radionuclide contaminants in ground water often begins with the development of conceptual and analytical models that guide our understanding of the processes controlling radionuclide transport. The reliability of these models is often predicated on the collection o...
Charge separation and transport of the n=2 instability in C-2 FRC plasmas
NASA Astrophysics Data System (ADS)
Deng, Bihe; Sun, Xuan; Tuszewski, Michel
2012-10-01
Charge separation is critical in the positive feedback loop for gravitational type instabilities to grow [1], such as in the case of the n=2 mode in the C-2 field reversed configuration (FRC) experiment [2]. A fast time response Langmuir probe with minimum perturbation to the plasma is inserted into the edge of the C-2 plasma to measure the plasma floating potential. With the combined plasma wobble motion and spin motion, 2-D scans of the plasma floating potential are obtained, and evidence of charge separation associated with the n=2 instability is observed. The transport due to charge separation is estimated. Charge neutralization can provide an alternative method to stabilize the n=2 mode. An experiment is proposed to test this method with two probes inserted into the plasma from two azimuthally separated ports and an external shorting circuit, to constantly neutralize the charge separation, thus suppress the growth of the n=2 mode. [4pt] [1] R.J. Goldston and P.H. Rutherford, Introduction to Plasma Physics (Institute of Physics Publishing, Bristol, 2000).[0pt] [2]. M.W. Binderbauer et al, Phys. Rev. Lett. 105, 045003 (2010).
Dula, Linda J; Shala, Kujtim Sh; Pustina-Krasniqi, Teuta; Bicaj, Teuta; Ahmedi, Enis F
2015-01-01
The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.
The effects of attentional focus in the preparation and execution of a standing long jump.
Becker, Kevin A; Fairbrother, Jeffrey T; Couvillion, Kaylee F
2018-04-03
Attentional focus research suggests an external focus leads to improved motor performance compared to an internal focus (Wulf in Int Rev Sport Exerc Psychol 6:77-104, 2013), but skilled athletes often report using an internal focus (Fairbrother et al., Front Psychol 7:1028, 2016) and sometimes shifting between different foci in the preparation and execution phases of performance (Bernier et al. in J Appl Sport Psychol 23:326-341, 2011; Bernier et al. in Sport Psychol 30:256-266, 2016). To date, focus shifts have been unexplored in experimental research, thus the purpose of this study was to determine the effect of shifting focus between the preparation and execution phases of a standing long jump. Participants (N = 29) completed two jumps in a control condition (CON), followed by two jumps in four experimental conditions presented in a counterbalanced order. Conditions included using an external focus (EF) and internal focus (IF) in both preparation and execution of the skill, as well as shifting from an internal focus in preparation to an external focus in execution (ITE), and an external focus in preparation to an internal focus in execution (ETI). Jump distance was analyzed with a repeated measures ANOVA. The main effect of condition was significant, p < .001, with EF producing longer jumps than all other conditions (p's < 0.05). ITE also generated farther jumps than IF and CON (p's < 0.05). The superiority of the EF and ITE conditions suggests that the focus employed in execution has the strongest impact on performance. Additionally, if an internal focus must be used in preparation, the performance decrement can be ameliorated by shifting to an external focus during execution.
The ITE Land classification: Providing an environmental stratification of Great Britain.
Bunce, R G; Barr, C J; Gillespie, M K; Howard, D C
1996-01-01
The surface of Great Britain (GB) varies continuously in land cover from one area to another. The objective of any environmentally based land classification is to produce classes that match the patterns that are present by helping to define clear boundaries. The more appropriate the analysis and data used, the better the classes will fit the natural patterns. The observation of inter-correlations between ecological factors is the basis for interpreting ecological patterns in the field, and the Institute of Terrestrial Ecology (ITE) Land Classification formalises such subjective ideas. The data inevitably comprise a large number of factors in order to describe the environment adequately. Single factors, such as altitude, would only be useful on a national basis if they were the only dominant causative agent of ecological variation.The ITE Land Classification has defined 32 environmental categories called 'land classes', initially based on a sample of 1-km squares in Great Britain but subsequently extended to all 240 000 1-km squares. The original classification was produced using multivariate analysis of 75 environmental variables. The extension to all squares in GB was performed using a combination of logistic discrimination and discriminant functions. The classes have provided a stratification for successive ecological surveys, the results of which have characterised the classes in terms of botanical, zoological and landscape features.The classification has also been applied to integrate diverse datasets including satellite imagery, soils and socio-economic information. A variety of models have used the structure of the classification, for example to show potential land use change under different economic conditions. The principal data sets relevant for planning purposes have been incorporated into a user-friendly computer package, called the 'Countryside Information System'.
Shanafelt, Tait D.; Raymond, Marilyn; Horn, Leora; Moynihan, Tim; Collichio, Frances; Chew, Helen; Kosty, Michael P.; Satele, Daniel; Sloan, Jeff; Gradishar, William J.
2014-01-01
Purpose To evaluate the career plans, professional expectations, and well-being of oncology fellows compared with actual experiences of practicing oncologists. Methods US oncology fellows taking the 2013 Medical Oncology In-Training Examination (MedOnc ITE) were invited to participate in an optional postexamination survey. The survey evaluated fellows' career plans and professional expectations and measured burnout, quality of life (QOL), fatigue, and satisfaction with work-life balance (WLB) using standardized instruments. Fellows' professional expectations and well-being were compared with actual experiences of US oncologists assessed simultaneously. Results Of the 1,637 oncology fellows in the United States, 1,373 (83.9%) took the 2013 MedOnc ITE. Among these, 1,345 (97.9%) completed the postexamination survey. The frequency of burnout among fellows decreased from 43.3% in year 1 to 31.7% in year 2 and 28.1% in year 3 (P < .001). Overall, the rate of burnout among fellows and practicing oncologists was similar (34.1% v 33.7%; P = .86). With respect to other dimensions of well-being, practicing oncologists had lower fatigue (P < .001) and better overall QOL scores (P < .001) than fellows but were less satisfied with WLB (P = .0031) and specialty choice (P < .001). Fellows' expectations regarding future work hours were 5 to 6 hours per week fewer than oncologists' actual reported work hours. Levels of burnout (P = .02) and educational debt (P ≤ .004) were inversely associated with ITE scores. Fellows with greater educational debt were more likely to pursue private practice and less likely to plan an academic career. Conclusion Oncology fellows entering practice trade one set of challenges for another. Unrealized expectations regarding work hours may contribute to future professional dissatisfaction, burnout, and challenges with WLB. PMID:25049326
Data mining of audiology patient records: factors influencing the choice of hearing aid type
2012-01-01
Background This paper describes the analysis of a database of over 180,000 patient records, collected from over 23,000 patients, by the hearing aid clinic at James Cook University Hospital in Middlesbrough, UK. These records consist of audiograms (graphs of the faintest sounds audible to the patient at six different pitches), categorical data (such as age, gender, diagnosis and hearing aid type) and brief free text notes made by the technicians. This data is mined to determine which factors contribute to the decision to fit a BTE (worn behind the ear) hearing aid as opposed to an ITE (worn in the ear) hearing aid. Methods From PCA (principal component analysis) four main audiogram types are determined, and are related to the type of hearing aid chosen. The effects of age, gender, diagnosis, masker, mould and individual audiogram frequencies are combined into a single model by means of logistic regression. Some significant keywords are also discovered in the free text fields by using the chi-squared (χ2) test, which can also be used in the model. The final model can act a decision support tool to help decide whether an individual patient should be offered a BTE or an ITE hearing aid. Results The final model was tested using 5-fold cross validation, and was able to replicate the decisions of audiologists whether to fit an ITE or a BTE hearing aid with precision in the range 0.79 to 0.87. Conclusions A decision support system was produced to predict the type of hearing aid which should be prescribed, with an explanation facility explaining how that decision was arrived at. This system should prove useful in providing a "second opinion" for audiologists. PMID:22595091
O'Neill, Thomas R; Peabody, Michael R; Song, Hao
2016-11-01
To examine the predictive validity of the National Board of Osteopathic Medical Examiners' Comprehensive Osteopathic Medical Licensing Examination of the United States of America (COMLEX-USA) series with regard to the American Board of Family Medicine's (ABFM's) In-Training Examination (ITE) and Maintenance of Certification for Family Physicians (MC-FP) Examination. A repeated-measures design was employed, using test scores across seven levels of training for 1,023 DOs who took the MC-FP for the first time between April 2012 and November 2014 and for whom the ABFM had ITE scores for each of their residency years. Pearson and disattenuated correlations were calculated; Fisher r to z transformation was performed; and sensitivity, specificity, and positive and negative predictive values for the COMLEX-USA Level 2-Cognitive Evaluation (CE) with regard to the MC-FP were computed. The Pearson and disattenuated correlations ranged from 0.55 to 0.69 and from 0.61 to 0.80, respectively. For MC-FP scores, only the correlation increase from the COMLEX-USA Level 2-CE to Level 3 was statistically significant (for Pearson correlations: z = 2.41, P = .008; for disattenuated correlations: z = 3.16, P < .001). The sensitivity, specificity, and positive and negative predictive values of the COMLEX-USA Level 2-CE with the MC-FP were 0.90, 0.39, 0.96, and 0.19, respectively. Evidence was found that the COMLEX-USA can assist family medicine residency program directors in predicting later resident performance on the ABFM's ITE and MC-FP, which is becoming increasingly important as graduate medical education accreditation moves toward a single aligned model.
Shanafelt, Tait D; Raymond, Marilyn; Horn, Leora; Moynihan, Tim; Collichio, Frances; Chew, Helen; Kosty, Michael P; Satele, Daniel; Sloan, Jeff; Gradishar, William J
2014-09-20
To evaluate the career plans, professional expectations, and well-being of oncology fellows compared with actual experiences of practicing oncologists. US oncology fellows taking the 2013 Medical Oncology In-Training Examination (MedOnc ITE) were invited to participate in an optional postexamination survey. The survey evaluated fellows’ career plans and professional expectations and measured burnout, quality of life (QOL), fatigue, and satisfaction with work-life balance (WLB) using standardized instruments. Fellows’ professional expectations and well-being were compared with actual experiences of US oncologists assessed simultaneously. Of the 1,637 oncology fellows in the United States, 1,373 (83.9%) took the 2013 MedOnc ITE. Among these, 1,345 (97.9%) completed the postexamination survey. The frequency of burnout among fellows decreased from 43.3% in year 1 to 31.7% in year 2 and 28.1% in year 3 (P < .001). Overall, the rate of burnout among fellows and practicing oncologists was similar (34.1% v. 33.7%; P = .86). With respect to other dimensions of well-being, practicing oncologists had lower fatigue (P < .001) and better overall QOL scores (P < .001) than fellows but were less satisfied with WLB (P = .0031) and specialty choice (P < .001). Fellows’ expectations regarding future work hours were 5 to 6 hours per week fewer than oncologists’ actual reported work hours. Levels of burnout (P = .02) and educational debt (P < or =.004) were inversely associated with ITE scores. Fellows with greater educational debt were more likely to pursue private practice and less likely to plan an academic career. Oncology fellows entering practice trade one set of challenges for another. Unrealized expectations regarding work hours may contribute to future professional dissatisfaction, burnout, and challenges with WLB.
NASA Technical Reports Server (NTRS)
Rediniotis, Othon K.
1999-01-01
Two new calibration algorithms were developed for the calibration of non-nulling multi-hole probes in compressible, subsonic flowfields. The reduction algorithms are robust and able to reduce data from any multi-hole probe inserted into any subsonic flowfield to generate very accurate predictions of the velocity vector, flow direction, total pressure and static pressure. One of the algorithms PROBENET is based on the theory of neural networks, while the other is of a more conventional nature (polynomial approximation technique) and introduces a novel idea of local least-squares fits. Both algorithms have been developed to complete, user-friendly software packages. New technology was developed for the fabrication of miniature multi-hole probes, with probe tip diameters all the way down to 0.035". Several miniature 5- and 7-hole probes, with different probe tip geometries (hemispherical, conical, faceted) and different overall shapes (straight, cobra, elbow probes) were fabricated, calibrated and tested. Emphasis was placed on the development of four stainless-steel conical 7-hole probes, 1/16" in diameter calibrated at NASA Langley for the entire subsonic regime. The developed calibration algorithms were extensively tested with these probes demonstrating excellent prediction capabilities. The probes were used in the "trap wing" wind tunnel tests in the 14'x22' wind tunnel at NASA Langley, providing valuable information on the flowfield over the wing. This report is organized in the following fashion. It consists of a "Technical Achievements" section that summarizes the major achievements, followed by an assembly of journal articles that were produced from this project and ends with two manuals for the two probe calibration algorithms developed.
Procedure for analysis and design of weaving sections : volume 2, users guide.
DOT National Transportation Integrated Search
1983-12-01
This research was performed to complete and advance the status of recently developed procedures for analysis and design of weaving sections (known as the Leisch method and-initially published in the 1979 issue of ITE Journal). The objective was to en...
2017-11-10
ALK-negative Anaplastic Large Cell Lymphoma; Peripherial T Cell Lymphoma,Not Otherwise Specified; Angioimmunoblastic T Cell Lymphoma; Enteropathy Associated T Cell Lymphoma; Hepatosplenic T Cell Lymphoma; Subcutaneous Panniculitis Like T Cell Lymphoma
A Proposed Logistics Career Development Model.
1986-09-01
1 Opportunity to express teelinas ing others (younger employees) about mid-ite ( anguish defeat. 2 Training for updating and integrating limited time... SPSS Incorporated. SPSSx User’s Guide (Second Edition). New York: McGraw-Hill Book Company, 1986. 48. Snyder William P. "Educating Military Officers
Embracing Inclusive Teacher Education
ERIC Educational Resources Information Center
Moran, Anne
2007-01-01
This paper examines the extent to which initial teacher education (ITE) programmes contribute to the development of inclusive attitudes, values and practices. Inclusive education is the entitlement of all children and young people to quality education, irrespective of their differences or dispositions. It is about embracing educational values of…
Establishment of Local Trip Generation Rates or Equations for Mixed-Use Developments in Kansas
DOT National Transportation Integrated Search
2012-10-01
Currently, the trip generation rates and equations contained in the Institute of Transportation Engineers (ITE) : Trip Generation Manual, 8th Edition are based on the information collected at single-use, free-standing sites and cannot : be directly a...
Correction of the wavefront using the irradiance transport equation
NASA Astrophysics Data System (ADS)
García, M.; Granados, F.; Cornejo, A.
2008-07-01
The correction of the wavefront in optical systems implies the use of wavefront sensors, software, and auxiliary optical systems. We propose evaluated the wavefront using the fact that the wavefront and its intensity are related in the mathematical expression the irradiance transport equation (ITE)
Derivation of Apollo 14 High-Al Basalts at Discrete Times: Rb-Sr Isotopic Constraints
NASA Astrophysics Data System (ADS)
Hui, H.; Neal, C. R.; Shih, C.-Y.; Nyquist, L. E.
2012-03-01
Four eruption episodes were identified for A-14 high-Al basalts. Rb-Sr isotopic data and ITE ratios show that their parental melt compositions of are correlated through mixing of evolved components with a relatively primitive magma ocean cumulate.
Touch the sky with your hands: a special Planetarium for blind, deaf, and motor disabled
NASA Astrophysics Data System (ADS)
García, Beatriz; Maya, Javier; Mancilla, Alexis; Álvarez, Silvina Pérez; Videla, Mariela; Yelós, Diana; Cancio, Angel
2015-03-01
The Planetarium for the blind, deaf, and motor disabled is part of the program on Astronomy and Inclusion of the Argentina Pierre Auger Foundation (FOPAA) and the Institute in Technologies and Detection of Astroparticles-Mendoza (ITeDAM).
Trip generation studies for special generators : research summary , December 17, 2009.
DOT National Transportation Integrated Search
2009-12-17
The Institute of Transportation Engineers (ITE) Trip Generation, 7th ed., which determines the number of : trips produced or attracted by different developments, does not include town centers as a type of land use. It : has also been argued that the ...
Phase retrieval in annulus sector domain by non-iterative methods
NASA Astrophysics Data System (ADS)
Wang, Xiao; Mao, Heng; Zhao, Da-zun
2008-03-01
Phase retrieval could be achieved by solving the intensity transport equation (ITE) under the paraxial approximation. For the case of uniform illumination, Neumann boundary condition is involved and it makes the solving process more complicated. The primary mirror is usually designed segmented in the telescope with large aperture, and the shape of a segmented piece is often like an annulus sector. Accordingly, It is necessary to analyze the phase retrieval in the annulus sector domain. Two non-iterative methods are considered for recovering the phase. The matrix method is based on the decomposition of the solution into a series of orthogonalized polynomials, while the frequency filtering method depends on the inverse computation process of ITE. By the simulation, it is found that both methods can eliminate the effect of Neumann boundary condition, save a lot of computation time and recover the distorted phase well. The wavefront error (WFE) RMS can be less than 0.05 wavelength, even when some noise is added.
Applications of elliptic operator theory to the isotropic interior transmission eigenvalue problem
NASA Astrophysics Data System (ADS)
Lakshtanov, E.; Vainberg, B.
2013-10-01
The paper concerns the isotropic interior transmission eigenvalue (ITE) problem. This problem is not elliptic, but we show that, using the Dirichlet-to-Neumann map, it can be reduced to an elliptic one. This leads to the discreteness of the spectrum as well as to certain results on a possible location of the transmission eigenvalues. If the index of refraction \\sqrt{n(x)} is real, then we obtain a result on the existence of infinitely many positive ITEs and the Weyl-type lower bound on its counting function. All the results are obtained under the assumption that n(x) - 1 does not vanish at the boundary of the obstacle or it vanishes identically, but its normal derivative does not vanish at the boundary. We consider the classical transmission problem as well as the case when the inhomogeneous medium contains an obstacle. Some results on the discreteness and localization of the spectrum are obtained for complex valued n(x).
Geochemical stratigraphy of two regolith cores from the Central Highlands of the moon
NASA Technical Reports Server (NTRS)
Korotev, R. L.
1991-01-01
High-resolution concentration profiles are presented for 20-22 chemical elements in the under 1-mm grain-size fractions of 60001-7 and 60009/10. Emphasis is placed on the stratigraphic features of the cores, and the fresh results are compared with those of previous petrographic and geochemical studies. For elements associated with major mineral phases, the variations in concentration in both cores exceed that observed in some 40 samples of surface and trench soils. Most of the variation in lithophile element concentrations at depths of 18 to 21 cm results from the mixing of two components - oil that is relatively mafic and rich in incompatible trace elements (ITEs), and coarse-grained anorthosite. The linearity of mixing lines on two-element concentration plots argues that the relative abundances of these various subcomponents are sufficiently uniform from sample to sample and from region to region in the core that the mixture behaves effectively as a single component. Soils at depths of 52-55 cm exhibit very low concentrations of ITEs.
Hellard, Philippe; Avalos, Marta; Millet, Gregoire; Lacoste, Lucien; Barale, Frederic; Chatard, Jean-Claude
2005-02-01
The aim of this study was to model the residual effects of training on the swimming performance and to compare a model that includes threshold saturation (MM) with the Banister model (BM). Seven Olympic swimmers were studied over a period of 4 +/- 2 years. For 3 training loads (low-intensity w(LIT), high-intensity w(HIT), and strength training w(ST)), 3 residual training effects were determined: short-term (STE) during the taper phase (i.e., 3 weeks before the performance [weeks 0, 1, and 2]), intermediate-term (ITE) during the intensity phase (weeks 3, 4, and 5), and long-term (LTE) during the volume phase (weeks 6, 7, and 8). ITE and LTE were positive for w(HIT) and w(LIT), respectively (p < 0.05). Low-intensity training load during taper was related to performances by a parabolic relationship (p < 0.05). Different quality measures indicated that MM compares favorably with BM. Identifying individual training thresholds may help individualize the distribution of training loads.
Grover, Blair K.; Hubbell, Joel M.; Sisson, James B.; Casper, William L.
2005-12-20
A method for collecting data regarding a matric potential of a media includes providing a tensiometer having a stainless steel tensiometer casing, the stainless steel tensiometer casing comprising a tip portion which includes a wetted porous stainless steel membrane through which a matric potential of a media is sensed; driving the tensiometer into the media using an insertion tube comprising a plurality of probe casing which are selectively coupled to form the insertion tube as the tensiometer is progressively driven deeper into the media, wherein the wetted porous stainless steel membrane is in contact with the media; and sensing the matric potential the media exerts on the wetted porous stainless steel membrane by a pressure sensor in fluid hydraulic connection with the porous stainless steel membrane. A tensiometer includes a stainless steel casing.
Folding and insertion thermodynamics of the transmembrane WALP peptide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bereau, Tristan, E-mail: bereau@mpip-mainz.mpg.de; Bennett, W. F. Drew; Pfaendtner, Jim
The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA){sub n} (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of meanmore » force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.« less
Folding and insertion thermodynamics of the transmembrane WALP peptide
NASA Astrophysics Data System (ADS)
Bereau, Tristan; Bennett, W. F. Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko
2015-12-01
The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide's insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.
Motorized fusion guided prostate biopsy: phantom study
NASA Astrophysics Data System (ADS)
Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.
2017-03-01
Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target 1, 2, and 3, respectively. The mechanical error was 0.75+/-0.4 mm, 0.45+/-0.4 mm, and 0.55+/-0.4 mm, for free hand approach while it was 1.0+/-0.57 mm, 0.45+/-0.4 mm, and 0.35+/-0.25 mm, for motorized approach, for target 1, 2, and 3, respectively. PPMCC remained almost at 1.0 for the motorized approach while having a variation between 0.9 and 1.0 for the free hand approach. Conclusions: motorized fusion guided prostate biopsy in a phantom study was feasible and non-inferior or comparable to the free hand manual approach in terms of accuracy and speed of targeting, while being superior in terms of repeatability and steadiness.
Szostak, Katarzyna M.; Grand, Laszlo; Constandinou, Timothy G.
2017-01-01
Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes—microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges. PMID:29270103
Park, HyungDal; Shin, Hyun-Joon; Cho, Il-Joo; Yoon, Eui-sung; Suh, Jun-Kyo Francis; Im, Maesoon; Yoon, Euisik; Kim, Yong-Jun; Kim, Jinseok
2011-01-01
In this paper, we report a neural probe which can selectively stimulate target neurons optically through Si wet etched mirror surface and record extracellular neural signals in iridium oxide tetrodes. Consequently, the proposed approach provides to improve directional problem and achieve at least 150/m gap distance between stimulation and recording sites by wet etched mirror surface in V-groove. Also, we developed light source, blue laser diode (OSRAM Blue Laser Diode_PL 450), integration through simple jig for one-touch butt-coupling. Furthermore, optical power and impedance of iridium oxide tetrodes were measured as 200 μW on 5 mW from LD and 206.5 k Ω at 1 kHz and we demonstrated insertion test of probe in 0.5% agarose-gel successfully. We have successfully transmitted a light of 450 nm to optical fiber through the integrated LD using by butt-coupling method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hauer, John F.; Mittelstadt, William; Martin, Kenneth E.
During 2005 and 2006 the Western Electricity Coordinating Council (WECC) performed three major tests of western system dynamics. These tests used a Wide Area Measurement System (WAMS) based primarily on Phasor Measurement Units (PMUs) to determine response to events including the insertion of the 1400-MW Chief Joseph braking resistor, probing signals, and ambient events. Test security was reinforced through real-time analysis of wide area effects, and high-quality data provided dynamic profiles for interarea modes across the entire western interconnection. The tests established that low-level optimized pseudo-random ±20-MW probing with the Pacific DC Intertie (PDCI) roughly doubles the apparent noise thatmore » is natural to the power system, providing sharp dynamic information with negligible interference to system operations. Such probing is an effective alternative to use of the 1400-MW Chief Joseph dynamic brake, and it is under consideration as a standard means for assessing dynamic security.« less
Coupling Microdialysis Sampling to Microchip Electrophoresis in a Reversibly Sealed Device
Mecker, Laura C.; Martin, R. Scott
2007-01-01
In this paper, we describe the fabrication and characterization of a reversibly sealed microchip device that is used to couple microdialysis sampling to microchip electrophoresis. The ability to interface microdialysis sampling and microchip electrophoresis in a device that is amenable to reversible sealing is advantageous from a repeated use standpoint. Commercially available tubing coming from the microdialysis probe is directly inserted into the chip and flow from the probe is interfaced to the electrophoresis portion of the device through integrated pneumatic valves. Fluorescence detection was used to characterize the poly(dimethylsiloxane)-based device in terms of injection reproducibility. It was found that the entire system (microdialysis probe and microchip device) has a concentration response lag time of 170 sec. Microdialysis sampling followed by an electrophoretic separation of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide was also demonstrated. PMID:18836517
3D silicon neural probe with integrated optical fibers for optogenetic modulation.
Kim, Eric G R; Tu, Hongen; Luo, Hao; Liu, Bin; Bao, Shaowen; Zhang, Jinsheng; Xu, Yong
2015-07-21
Optogenetics is a powerful modality for neural modulation that can be useful for a wide array of biomedical studies. Penetrating microelectrode arrays provide a means of recording neural signals with high spatial resolution. It is highly desirable to integrate optics with neural probes to allow for functional study of neural tissue by optogenetics. In this paper, we report the development of a novel 3D neural probe coupled simply and robustly to optical fibers using a hollow parylene tube structure. The device shanks are hollow tubes with rigid silicon tips, allowing the insertion and encasement of optical fibers within the shanks. The position of the fiber tip can be precisely controlled relative to the electrodes on the shank by inherent design features. Preliminary in vivo rat studies indicate that these devices are capable of optogenetic modulation simultaneously with 3D neural signal recording.
NASA Technical Reports Server (NTRS)
Hudson, S. T.; Bordelon, W. J., Jr.; Smith, A. W.; Ramachandran, N.
1995-01-01
The main objective of this test was to obtain detailed radial and circumferential flow surveys at the inlet and exit of the SSME High Pressure Fuel Turbine model using three-hole cobra probes, hot-film probes, and a laser velocimeter. The test was designed to meet several objectives. First, the techniques for making laser velocimeter, hot-film probe, and cobra probe measurements in turbine flows were developed and demonstrated. The ability to use the cobra probes to obtain static pressure and, therefore, velocity had to be verified; insertion techniques had to be established for the fragile hot-film probes; and a seeding method had to be established for the laser velocimetry. Once the measurement techniques were established, turbine inlet and exit velocity profiles, temperature profiles, pressure profiles, turbulence intensities, and boundary layer thicknesses were measured at the turbine design point. The blockage effect due to the model inlet and exit total pressure and total temperature rakes on the turbine performance was also studied. A small range of off-design points were run to obtain the profiles and to verify the rake blockage effects off-design. Finally, a range of different Reynolds numbers were run to study the effect of Reynolds number on the various measurements.
Intra-opeartive OCT imaging and sensing devices for clinical translation (Conference Presentation)
NASA Astrophysics Data System (ADS)
Chen, Yu
2017-02-01
Stereotactic procedures that require insertion of needle-based instruments into the brain serve important roles in a variety of neurosurgical interventions, such as biopsy, catheterization, and electrode placement. A fundamental limitation of these stereotactic procedures is that they are blind procedures in that the operator does not have real-time feedback as to what lies immediately ahead of the advancing needle. Therefore, there is a great clinical need to navigate the instrument safely and accurately to the targets. Towards that end, we developed a forwarding-imaging needle-type optical coherence tomography (OCT) probe for avoiding the hemorrhage and guiding neurosurgical interventions. The needle probe has a thin diameter of 0.7 mm. The feasibility of vessel detection and neurosurgical guidance were demonstrated on sheep brain in vivo and human brain ex vivo. In addition, we further reduced the probe size to 0.3 mm using an optical Doppler sensing (ODS) fiber probe that can integrate with microelectrode recording (MER) to detect the blood vessels lying ahead to improve the safety of this procedure. Furthermore, to overcome the field-of-view limitation of OCT probe, we developed an MRI-compatible OCT imaging probe for neurosurgery. MRI/OCT multi-scale imaging integrates micro-resolution optical imaging with wide-field MRI imaging, and has potential to further improve the targeting accuracy.
Hooks, David O; Rehm, Bernd H A
2015-10-01
The polyhydroxyalkanoate (PHA) synthase catalyzes the synthesis of PHA and remains attached to the hydrophobic PHA inclusions it creates. Although this feature is actively exploited to generate functionalized biobeads via protein engineering, little is known about the structure of the PHA synthase. Here, the surface topology of Ralstonia eutropha PHA synthase was probed to inform rational protein engineering toward the production of functionalized PHA beads. Surface-exposed residues were detected by conjugating biotin to inclusion-bound PHA synthase and identifying the biotin-conjugated lysine and cysteine residues using peptide fingerprinting analysis. The identified sites (K77, K90, K139, C382, C459, and K518) were investigated as insertion sites for the generation of new protein fusions. Insertions of FLAG epitopes into exposed sites K77, K90, K139, and K518 were tolerated, retaining >65 % of in vivo activity. Sites K90, K139, and K518 were also tested by insertion of the immunoglobulin G (IgG)-binding domain (ZZ), successfully producing PHA inclusions able to bind human IgG in vitro. Although simultaneous insertions of the ZZ domain into two sites was permissive, insertion at all three lysine sites inactivated the synthase. The K90/K139 double ZZ insertion had the optimum IgG-binding capacity of 16 mg IgG/g wet PHA beads and could selectively purify the IgG fraction from human serum. Overall, this study identified surface-exposed flexible regions of the PHA synthase which either tolerate protein/peptide insertions or are critical for protein function. This further elucidates the structure and function of PHA synthase and provides new opportunities for generating functionalized PHA biobeads.
OEDGE Modeling of Collector Probe measurements in L-mode from the DIII-D tungsten ring campaign
NASA Astrophysics Data System (ADS)
Elder, J. D.; Stangeby, P. C.; Unterberg, Z.; Donovan, D.; Wampler, W. R.; Watkins, J.; Abrams, T.; McLean, A. G.
2017-10-01
During the tungsten ring campaign on DIII-D, a collector probe system with multiple diameter, dual-facing collector rods was inserted into the far scrape off layer (SOL) near the outer midplane to measure the plasma tungsten content. For most probes more tungsten was observed on the side connected along field lines to the inner divertor, with the larger probes showing largest divertor-facing asymmetries The OEDGE code is used to model the tungsten erosion, transport and deposition. It has been enhanced with (i) a peripheral particle transport and deposition model to record the impurity content in the peripheral region outside the regular mesh, and (ii) a collector probe model. The OEDGE results approximately reproduce both the divertor-facing asymmetries and the radial decay of each collector probe profile. The effect of changing impurity transport assumptions and wall location are examined. The measured divertor-facing asymmetries imply a higher tungsten density in the plasma upstream of the probe; this was expected theoretically from the effect of the parallel ion temperature gradient force driving upstream transport of tungsten from the outer divertor and was also found in the code analysis. Work supported by the US Department of Energy under DE-FC02-04ER54698, DE-NA0003525, DE-AC05-00OR22725, and DE-AC52-07NA27344.
Urbanchek, Melanie G; Wei, Benjamin; Egeland, Brent M; Abidian, Mohammad R; Kipke, Daryl R; Cederna, Paul S
2011-01-01
Background Our goal is to develop a peripheral nerve electrode with long-term stability and fidelity for use in nerve-machine interfaces. Microelectromechanical systems (MEMS) use silicon probes that contain multi-channel actuators, sensors, and electronics. We tested the null hypothesis that implantation of MEMS probes do not have a detrimental effect on peripheral nerve function or regeneration. Methods A rat hindlimb, peroneal nerve model was utilized in all experimental groups: a) intact nerve (Control, n= 10); b) nerve division and repair (Repair, n= 9); and c) Nerve division, insertion of MEMS probe, and repair (Repair + Probe, n=9). Nerve morphology, nerve to muscle compound action potential (CMAP) studies, walking tracks, and extensor digitorum longus (EDL) muscle function tests were evaluated following an 80 day recovery. Results Repair and Repair + Probe showed no differences in axon count, axon size, percent non-neural area, CMAP amplitude, latency, muscle mass, muscle force, or walking track scores. Though there was some local fibrosis around each MEMS probe, this did not lead to measurable detrimental effects in any anatomic or functional outcome measurements. Conclusions The lack of a significant difference between Repair and Repair + Probe groups in histology, CMAP, walking tracks, and muscle force suggests that MEMS electrodes are compatible with regenerating axons and show promise for establishing chemical and electrical interfaces with peripheral nerves. PMID:21921739
Xu, Zhicheng; Bai, Guan; Dong, Chuan
2005-10-15
The interaction of a new intramolecular charge transfer probe, namely 4'-dimethylamino-2,5-dihydroxychalcone (DMADHC), with calf thymus DNA has been studied. Compared to the spectral characteristics of the free form in aqueous solution, the fluorescence of DMADHC enhanced dramatically accompanying a blueshift of the emission maxima in the presence of DNA. The absorption and fluorescence spectra, salt concentration effect, KI quenching, fluorescence polarization, and DNA denaturation experiments were given. These results give evidence that the DMADHC molecule is inserted into the base-stacking domain of the DNA double helix. The intrinsic binding constant and the binding site number were estimated. The analytical characteristics were also given.
Method and apparatus for preloading a joint by remotely operable means
NASA Technical Reports Server (NTRS)
Kahn, Jon B. (Inventor)
1993-01-01
The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.
Method and apparatus for preloading a joint by remotely operable means
NASA Technical Reports Server (NTRS)
Shelton, Robert O. (Inventor)
1992-01-01
The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.
Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A
2014-08-01
To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Optical probe for determining the fat/lean interface in cuts of meat
Weber, Thomas M.; Callow, Diane S.; Jones, James F.; Kuehl, Michael A.; Spletzer, Barry L.
2005-02-22
An apparatus and method for locating the boundary surface between a layer of fatty tissue and lean tissue in a cut of meat, such as beef, such as slabs of meat undergoing trimming and cutting in commercial meet processing facilitates. The invention exploits the fact that fatty tissue and lean tissue have significantly different responses to incident light energy. By gauging the degree to which a generated beam of light is scattered and reflected by the tissues under evaluation, the invention permits the character of the tissue to be ascertained. An incident beam of light, such as green light, is generated and transmitted to a probe tip, which tip is inserted into the cut of meat under investigation. The light beam is emitted into the meat tissues from the probe tip, and then is scattered and reflected by the tissues, whereupon some fraction of the emitted light returns to the probe tip. The returning light energy is transmitted to a detector; relative changes in the returning light transmitted to the detector permit the operator to determine when the probe tip is approaching or penetrating the fat/lean tissue interface.
Building large mosaics of confocal edomicroscopic images using visual servoing.
Rosa, Benoît; Erden, Mustafa Suphi; Vercauteren, Tom; Herman, Benoît; Szewczyk, Jérôme; Morel, Guillaume
2013-04-01
Probe-based confocal laser endomicroscopy provides real-time microscopic images of tissues contacted by a small probe that can be inserted in vivo through a minimally invasive access. Mosaicking consists in sweeping the probe in contact with a tissue to be imaged while collecting the video stream, and process the images to assemble them in a large mosaic. While most of the literature in this field has focused on image processing, little attention has been paid so far to the way the probe motion can be controlled. This is a crucial issue since the precision of the probe trajectory control drastically influences the quality of the final mosaic. Robotically controlled motion has the potential of providing enough precision to perform mosaicking. In this paper, we emphasize the difficulties of implementing such an approach. First, probe-tissue contacts generate deformations that prevent from properly controlling the image trajectory. Second, in the context of minimally invasive procedures targeted by our research, robotic devices are likely to exhibit limited quality of the distal probe motion control at the microscopic scale. To cope with these problems visual servoing from real-time endomicroscopic images is proposed in this paper. It is implemented on two different devices (a high-accuracy industrial robot and a prototype minimally invasive device). Experiments on different kinds of environments (printed paper and ex vivo tissues) show that the quality of the visually servoed probe motion is sufficient to build mosaics with minimal distortion in spite of disturbances.
Assessing Instructional Modalities: Individualized Treatment Effects for Personalized Learning
ERIC Educational Resources Information Center
Beemer, Joshua; Spoon, Kelly; Fan, Juanjuan; Stronach, Jeanne; Frazee, James P.; Bohonak, Andrew J.; Levine, Richard A.
2018-01-01
Estimating the efficacy of different instructional modalities, techniques, and interventions is challenging because teaching style covaries with instructor, and the typical student only takes a course once. We introduce the individualized treatment effect (ITE) from analyses of personalized medicine as a means to quantify individual student…
DOT National Transportation Integrated Search
2003-01-01
The Institute of Transportation Engineers (ITE) formed a panel of experts from federal, state and local governments, as well as academia and the private sector, to share knowledge and experiences in addressing red-light running using engineering coun...
DOT National Transportation Integrated Search
2012-10-01
Currently, the trip generation rates and equations contained in the Institute of Transportation Engineers (ITE) Trip Generation Manual, 8th Edition are based on the information collected at single-use, free-standing sites and cannot be directly appli...
Reconciling Dichotomous Demands: Telemarketing Agents in Bangalore and Mumbai, India
ERIC Educational Resources Information Center
Noronha, Ernesto; D'Cruz, Premilla
2007-01-01
Though outsourcing has created enormous employment potential in India's information technology enabled services/business process outsourcing (ITES/BPO) sector, the implications for employees remain to be understood. The present paper describes employee experiences in telemarketing outbound call centers in Bangalore and Mumbai, India. Following van…
Long-term effect of tetracycline fibers on recurrent lesions in periodontal maintenance patients.
Corsair, A
1994-01-01
Thirty-one patients with chronic adult periodontitis participated in this long-term private practice study. Sixty-one sites with moderate (4-6 mm, n = 21) or deep (> or = 7 mm, n = 40) periodontal pockets and bleeding on probing were treated with an antibiotic-releasing fiber, Actisite (Periodontal Therapeutic System) (tetracycline hydrochloride). Scaling/root planing (SRP) was performed on all teeth 3 weeks before start of the study, and on most teeth immediately before fiber insertion. Monolithic fibers loaded with 25% tetracycline hydrochloride were inserted in periodontal pockets, where they were retained for a mean of 6.7 days, at which point they were removed. Patients were evaluated at 1, 3, and 6 months after treatment; subgroups were also evaluated at normalized 12-month (10 patients, 20 sites) and 24-month (13 patients, 20 sites) time points. Sites showed a mean probing depth reduction of 2.5 mm at 6 months, and 2.2 mm at 24 months, with the deepest sites showing the greatest reduction. Bleeding on probing was 100% at baseline, 34% at 3 months, and 50% at 6 months. Attachment gains in 18 patients (25 sites) were 2.4 mm at 1 month, 3.0 mm at 3 months, and 2.5 mm at 6 months. Fibers were well tolerated; no adverse effects from treatment were noted. These results indicate that use of tetracycline fiber plus SRP clearly reduced the clinical signs of periodontal disease and maintained or improved attachment for up to 24 months in sites previously refractory to treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yordanov, D., E-mail: yordanov@phys.uni-sofia.bg; Lishev, St.; Shivarova, A.
Shielding the bias applied to the probe by the sheath formed around it and determination of parameters of unperturbed plasmas are in the basis of the probe diagnostics. The results from a two-dimensional model of a discharge with a probe inserted in it show that the probe influences the spatial distribution of the plasma parameters in the entire discharge. The increase (although slight) in the electron temperature, due to the increased losses of charged particles on the additional wall in the discharge (mainly the probe holder), leads to redistribution of the plasma density and plasma potential, as shown by themore » results obtained at the floating potential of the probe. The deviations due to the bias applied to the probe tip are stronger in the ion saturation region of the probe characteristics. The pattern of the spatial redistribution of the plasma parameters advances together with the movement of the probe deeper in the discharge. Although probe sheaths and probe characteristics resulting from the model are shown, the study does not aim at discussions on the theories for determination of the plasma density from the ion saturation current. Regardless of the modifications in the plasma behavior in the entire discharge, the deviations of the plasma parameters at the position of the probe tip and, respectively, the uncertainty which should be added as an error when the accuracy of the probe diagnostics is estimated do not exceed 10%. Consequently, the electron density and temperature obtained, respectively, at the position of the plasma potential on the probe characteristics and from its transition region are in reasonable agreement with the results from the model of the discharge without a probe. Being in the scope of research on a source of negative hydrogen ions with the design of a matrix of small radius inductive discharges, the model is specified for a low-pressure hydrogen discharge sustained in a small-radius tube.« less
Musteata, Florin Marcel; Sandoval, Manuel; Ruiz-Macedo, Juan C; Harrison, Kathleen; McKenna, Dennis; Millington, William
2016-08-24
Although solid phase microextraction (SPME) has been used extensively for fingerprinting volatile compounds emitted by plants, there are very few such reports for direct insertion SPME. In this research, direct contact of SPME probes with the interstitial fluid of plants was investigated as a method for phytochemical analysis. Medicinal plants from the Amazon have been the source of numerous drugs used in western medicine. However, a large number of species used in traditional medicine have not been characterized chemically, partly due to the difficulty of field work. In this project, the phytochemical composition of plants from several genera was fingerprinted by combining convenient field sampling by solid phase microextraction (SPME) with laboratory analysis by LC-MS. The new method was compared with classical sampling followed by liquid extraction (LE). SPME probes were prepared by coating stainless steel wires with a mixture of polyacrylonitrile and either RP-amide or HS-F5 silica particles. Sampling was performed by inserting the microextraction probes into various tissues of living plants in their natural environment. After in vivo extraction, the probes were sealed under vacuum and refrigerated until analyzed. The probes were desorbed in mobile phase and analyzed on a Waters Acquity UPLC with triple quadrupole mass spectrometer in positive ion mode. Twenty Amazonian plant species were sampled and unique metabolomic fingerprints were obtained. In addition, quantitative analysis was performed for previously identified compounds in three species. Comparison of the fingerprints obtained by in vivo SPME with those obtained by LE showed that 27% of the chromatographic features were unique to SPME, 57% were unique to LE, and 16% were common to both methods. In vivo SPME caused minimal damage to the plants, was much faster than traditional liquid extraction, and provided unique fingerprints for all investigated plants. SPME revealed unique chromatographic features, undetected by traditional extraction, although it produced only half as many peaks as ethanol extraction. Copyright © 2016 Elsevier B.V. All rights reserved.
Elnaggar, Sameh Y; Tervo, Richard; Mattar, Saba M
2014-05-01
A cavity (CV) with a dielectric resonator (DR) insert forms an excellent probe for the use in electron paramagnetic resonance (EPR) spectrometers. The probe's coupling coefficient, κ, the quality factor, Q, and the filling factor, η are vital in assessing the EPR spectrometer's performance. Coupled mode theory (CMT) is used to derive general expressions for these parameters. For large permittivity the dominating factor in κ is the ratio of the DR and CV cross sectional areas rather than the dielectric constant. Thus in some cases, resonators with low dielectric constant can couple much stronger with the cavity than do resonators with a high dielectric constant. When the DR and CV frequencies are degenerate, the coupled η is the average of the two uncoupled ones. In practical EPR probes the coupled η is approximately half of that of the DR. The Q of the coupled system generally depends on the eigenvectors, uncoupled frequencies (ω1,ω2) and the individual quality factors (Q1,Q2). It is calculated for different probe configurations and found to agree with the corresponding HFSS® simulations. Provided there is a large difference between the Q1, Q2 pair and the frequencies of DR and CV are degenerate, Q is approximately equal to double the minimum of Q1 and Q2. In general, the signal enhancement ratio, Iwithinsert/Iempty, is obtained from Q and η. For low loss DRs it only depends on η1/η2. However, when the DR has a low Q, the uncoupled Qs are also needed. In EPR spectroscopy it is desirable to excite only a single mode. The separation between the modes, Φ, is calculated as a function of κ and Q. It is found to be significantly greater than five times the average bandwidth. Thus for practical probes, it is possible to excite one of the coupled modes without exciting the other. The CMT expressions derived in this article are quite general and are in excellent agreement with the lumped circuit approach and finite numerical simulations. Hence they can also be applied to a loop-gap resonator in a cavity. For the design effective EPR probes, one needs to consider the κ, Q and η parameters. Copyright © 2014 Elsevier Inc. All rights reserved.
Plant Available Nutrients, Barrow, Alaska, Ver. 1
Sloan, Victoria; Liebig, Jenny; Curtis, Bryan; Hahn, Melanie; Iversen, Colleen; Siegrist, Julie
2014-02-19
This dataset consists of measurements of plant available nutrients made using Plant Root Simulator probes (Western Ag Innovations Inc.) during 2012 and 2013. In 2012, Ca, Mg, K, P, Fe, Mn, Cu, Zn, B, S, Pb, Al, Cd, NO3-N and NH4-N were measured during spring, summer and winter in the centers, edges and troughs of four polygons in each of four areas of contrasting moisture regime and polygon type. In 2013, probes were installed in centers, edges and troughs of four polygons in each of two areas (high-centered and low-centered polygons) at two-week intervals and at 3 soil depths to capture fine-scale season dynamics of NO3-N and NH4-N. PRS probes are ion exchange resin membranes held in plastic supports that are inserted into soil to measure ion supply in situ. The anion and cation exchange with the membrane is intended to mimic plant uptake and thus provide a relevant measure of soil nutrient bioavailability. Measurements are made per area of probe membrane and cannot be converted to concentrations or related to soil volume.
A Real-Time Method for Estimating Viscous Forebody Drag Coefficients
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Hurtado, Marco; Rivera, Jose; Naughton, Jonathan W.
2000-01-01
This paper develops a real-time method based on the law of the wake for estimating forebody skin-friction coefficients. The incompressible law-of-the-wake equations are numerically integrated across the boundary layer depth to develop an engineering model that relates longitudinally averaged skin-friction coefficients to local boundary layer thickness. Solutions applicable to smooth surfaces with pressure gradients and rough surfaces with negligible pressure gradients are presented. Model accuracy is evaluated by comparing model predictions with previously measured flight data. This integral law procedure is beneficial in that skin-friction coefficients can be indirectly evaluated in real-time using a single boundary layer height measurement. In this concept a reference pitot probe is inserted into the flow, well above the anticipated maximum thickness of the local boundary layer. Another probe is servomechanism-driven and floats within the boundary layer. A controller regulates the position of the floating probe. The measured servomechanism position of this second probe provides an indirect measurement of both local and longitudinally averaged skin friction. Simulation results showing the performance of the control law for a noisy boundary layer are then presented.
Kolanko, C J; Pyle, M D; Nath, J; Prasanna, P G; Loats, H; Blakely, W F
2000-03-01
We report a low cost and efficient method for synthesizing a human pancentromeric DNA probe by the polymerase chain reaction (PRC) and an optimized protocol for in situ detection using color pigment immunostaining. The DNA template used in the PCR was a 2.4 kb insert containing human alphoid repeated sequences of pancentromeric DNA subcloned into pUC9 (Miller et al. 1988) and the primers hybridized to internal sequences of the 172 bp consensus tandem repeat associated with human centromeres. PCR was performed in the presence of biotin-11-dUTP, and the product was used for in situ hybridization to detect the pancentromeric region of human chromosomes in metaphase spreads. Detection of pancentromeric probe was achieved by immunoenzymatic color pigment painting to yield a permanent image detected at high resolution by bright field microscopy. The ability to synthesize the centromeric probe rapidly and to detect it with color pigment immunostaining will lead to enhanced identification and eventually to automation of various chromosome aberration assays.