NASA Astrophysics Data System (ADS)
Morgan, T. W.; van den Berg, M. A.; De Temmerman, G.; Bardin, S.; Aussems, D. U. B.; Pitts, R. A.
2017-12-01
For the final design of the ITER divertor it is important to determine whether shaping of each tungsten monoblock to eliminate leading edges is required or not. In order to aid this decision, two experiments were performed in DIFFER’s linear plasma devices to study heat loads on misaligned water cooled blocks at glancing incidence. First, a series of tungsten blocks were exposed to a high parallel heat flux (26 MW \
Dutot, Camille; Mercier, Grégoire; Borget, Isabelle; de Sauvebeuf, Côme; Martelli, Nicolas
2017-01-01
Within French university hospitals, some internal committees are in charge of conducting hospital-based health technology assessment (Hb-HTA) to support managerial decisions regarding the adoption of innovations. For manufacturers, hospitals are usually the entry point for new and innovative medical devices, which cannot be accessed without the Hb-HTA committees' approval. Thus, the main objective of this pilot survey was to explore manufacturers' insights into Hb-HTA processes. A two-step pilot survey was conducted in 2014. First, semi-structured phone interviews were carried out to capture manufacturers' feedback on the Hb-HTA procedure. Second, a prospective and iterative questionnaire designed to explore manufacturers' market access strategies was administered. Eight manufacturers from the medical device industry completed the retrospective phone interviews, and five of them participated in the prospective survey. According to the overall feedback, the Hb-HTA process timeline and transparency are major issues, and the expectations of internal committees, especially in terms of clinical evidence, remain difficult to understand. However, despite this and due to the complexity of reimbursement processes at the national level, manufacturers are increasingly considering hospital adoption through Hb-HTA submission as a viable market access and coverage opportunity. Our study reaffirms the primary role of hospitals in the diffusion of innovative medical devices. However, to ensure efficient and broad access to innovation, cooperation between local and national HTA bodies is critical and should be promoted.
Coded DS-CDMA Systems with Iterative Channel Estimation and no Pilot Symbols
2010-08-01
ar X iv :1 00 8. 31 96 v1 [ cs .I T ] 1 9 A ug 2 01 0 1 Coded DS - CDMA Systems with Iterative Channel Estimation and no Pilot Symbols Don...sequence code-division multiple-access ( DS - CDMA ) systems with quadriphase-shift keying in which channel estimation, coherent demodulation, and decoding...amplitude, phase, and the interference power spectral density (PSD) due to the combined interference and thermal noise is proposed for DS - CDMA systems
Development and Feasibility of a Structured Goals of Care Communication Guide.
Bekelman, David B; Johnson-Koenke, Rachel; Ahluwalia, Sangeeta C; Walling, Anne M; Peterson, Jamie; Sudore, Rebecca L
2017-09-01
Discussing goals of care and advance care planning is beneficial, yet how to best integrate goals of care communication into clinical care remains unclear. To develop and determine the feasibility of a structured goals of care communication guide for nurses and social workers. Developmental study with providers in an academic and Veterans Affairs (VA) health system (n = 42) and subsequent pilot testing with patients with chronic obstructive pulmonary disease or heart failure (n = 15) and informal caregivers (n = 4) in a VA health system. During pilot testing, the communication guide was administered, followed by semistructured, open-ended questions about the content and process of communication. Changes to the guide were made iteratively, and subsequent piloting occurred until no additional changes emerged. Provider and patient feedback to the communication guide. Iterative input resulted in the goals of care communication guide. The guide included questions to elicit patient understanding of and attitudes toward the future of illness, clarify values and goals, identify end-of-life preferences, and agree on a follow-up plan. Revisions to guide content and phrasing continued during development and pilot testing. In pilot testing, patients validated the importance of the topic; none said the goals of care discussion should not be conducted. Patients and informal caregivers liked the final guide length (∼30 minutes), felt it flowed well, and was clear. In this developmental and pilot study, a structured goals of care communication guide was iteratively designed, implemented by nurses and social workers, and was feasible based on administration time and acceptability by patients and providers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prindle, N.H.; Mendenhall, F.T.; Trauth, K.
1996-05-01
The Systems Prioritization Method (SPM) is a decision-aiding tool developed by Sandia National Laboratories (SNL). SPM provides an analytical basis for supporting programmatic decisions for the Waste Isolation Pilot Plant (WIPP) to meet selected portions of the applicable US EPA long-term performance regulations. The first iteration of SPM (SPM-1), the prototype for SPM< was completed in 1994. It served as a benchmark and a test bed for developing the tools needed for the second iteration of SPM (SPM-2). SPM-2, completed in 1995, is intended for programmatic decision making. This is Volume II of the three-volume final report of the secondmore » iteration of the SPM. It describes the technical input and model implementation for SPM-2, and presents the SPM-2 technical baseline and the activities, activity outcomes, outcome probabilities, and the input parameters for SPM-2 analysis.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications AGENCY: Food and... feasibility study investigational device exemption (IDE) applications. The pilot program will conform to the... Feasibility Medical Device Clinical Studies, Including Certain First in Human (FIH) Studies.'' Under the pilot...
NASA Technical Reports Server (NTRS)
Hruby, Vladimir (Inventor); Demmons, Nathaniel (Inventor); Ehrbar, Eric (Inventor); Pote, Bruce (Inventor); Rosenblad, Nathan (Inventor)
2014-01-01
An autonomous method for minimizing the magnitude of plasma discharge current oscillations in a Hall effect plasma device includes iteratively measuring plasma discharge current oscillations of the plasma device and iteratively adjusting the magnet current delivered to the plasma device in response to measured plasma discharge current oscillations to reduce the magnitude of the plasma discharge current oscillations.
Leiner, Claude; Nemitz, Wolfgang; Schweitzer, Susanne; Kuna, Ladislav; Wenzl, Franz P; Hartmann, Paul; Satzinger, Valentin; Sommer, Christian
2016-03-20
We show that with an appropriate combination of two optical simulation techniques-classical ray-tracing and the finite difference time domain method-an optical device containing multiple diffractive and refractive optical elements can be accurately simulated in an iterative simulation approach. We compare the simulation results with experimental measurements of the device to discuss the applicability and accuracy of our iterative simulation procedure.
Point-of-Care Technologies for Precision Cardiovascular Care and Clinical Research
King, Kevin; Grazette, Luanda P.; Paltoo, Dina N.; McDevitt, John T.; Sia, Samuel K.; Barrett, Paddy M.; Apple, Fred S.; Gurbel, Paul A.; Weissleder, Ralph; Leeds, Hilary; Iturriaga, Erin J.; Rao, Anupama; Adhikari, Bishow; Desvigne-Nickens, Patrice; Galis, Zorina S.; Libby, Peter
2016-01-01
Point-of-care technologies (POC or POCT) are enabling innovative cardiovascular diagnostics that promise to improve patient care across diverse clinical settings. The National Heart, Lung, and Blood Institute convened a working group to discuss POCT in cardiovascular medicine. The multidisciplinary working group, which included clinicians, scientists, engineers, device manufacturers, regulatory officials, and program staff, reviewed the state of the POCT field; discussed opportunities for POCT to improve cardiovascular care, realize the promise of precision medicine, and advance the clinical research enterprise; and identified barriers facing translation and integration of POCT with existing clinical systems. A POCT development roadmap emerged to guide multidisciplinary teams of biomarker scientists, technologists, health care providers, and clinical trialists as they: 1) formulate needs assessments; 2) define device design specifications; 3) develop component technologies and integrated systems; 4) perform iterative pilot testing; and 5) conduct rigorous prospective clinical testing to ensure that POCT solutions have substantial effects on cardiovascular care. PMID:26977455
NASA Technical Reports Server (NTRS)
Leonard, Michael W.
2013-01-01
Integration of the Control Allocation technique to recover from Pilot Induced Oscillations (CAPIO) System into the control system of a Short Takeoff and Landing Mobility Concept Vehicle simulation presents a challenge because the CAPIO formulation requires that constrained optimization problems be solved at the controller operating frequency. We present a solution that utilizes a modified version of the well-known L-BFGS-B solver. Despite the iterative nature of the solver, the method is seen to converge in real time with sufficient reliability to support three weeks of piloted runs at the NASA Ames Vertical Motion Simulator (VMS) facility. The results of the optimization are seen to be excellent in the vast majority of real-time frames. Deficiencies in the quality of the results in some frames are shown to be improvable with simple termination criteria adjustments, though more real-time optimization iterations would be required.
NASA Astrophysics Data System (ADS)
Philipps, V.; Malaquias, A.; Hakola, A.; Karhunen, J.; Maddaluno, G.; Almaviva, S.; Caneve, L.; Colao, F.; Fortuna, E.; Gasior, P.; Kubkowska, M.; Czarnecka, A.; Laan, M.; Lissovski, A.; Paris, P.; van der Meiden, H. J.; Petersson, P.; Rubel, M.; Huber, A.; Zlobinski, M.; Schweer, B.; Gierse, N.; Xiao, Q.; Sergienko, G.
2013-09-01
Analysis and understanding of wall erosion, material transport and fuel retention are among the most important tasks for ITER and future devices, since these questions determine largely the lifetime and availability of the fusion reactor. These data are also of extreme value to improve the understanding and validate the models of the in vessel build-up of the T inventory in ITER and future D-T devices. So far, research in these areas is largely supported by post-mortem analysis of wall tiles. However, access to samples will be very much restricted in the next-generation devices (such as ITER, JT-60SA, W7-X, etc) with actively cooled plasma-facing components (PFC) and increasing duty cycle. This has motivated the development of methods to measure the deposition of material and retention of plasma fuel on the walls of fusion devices in situ, without removal of PFC samples. For this purpose, laser-based methods are the most promising candidates. Their feasibility has been assessed in a cooperative undertaking in various European associations under EFDA coordination. Different laser techniques have been explored both under laboratory and tokamak conditions with the emphasis to develop a conceptual design for a laser-based wall diagnostic which is integrated into an ITER port plug, aiming to characterize in situ relevant parts of the inner wall, the upper region of the inner divertor, part of the dome and the upper X-point region.
ERIC Educational Resources Information Center
Stefansson, Lilja S.; Webb, M. Elizabeth; Hebert, Luciana E.; Masinter, Lisa; Gilliam, Melissa L.
2018-01-01
Background: Adolescents experience numerous barriers to obtaining sexual and reproductive health care (SRHC). Mobile Health Units (MHUs) can remove some barriers by traveling to the community. This pilot study developed Mobile SRHC through an iterative process on an existing MHU and evaluated it among adolescents and providers. Methods: Mobile…
On the Implementation of Iterative Detection in Real-World MIMO Wireless Systems
2003-12-01
multientr~es et multisorties (MIMO) permettent une exploitation remarquable du spectre comparativement aux syst~mes traditionnels A antenne unique...vecteurs symboliques pilotes connus cause une perte de rendement n~gligeable comparativement au cas hypothdtique des connaissances des voies parfaites...useful design guidelines for iterative systems. it does not provide any fundamental understanding as to how the design of the detector can improve the
14 CFR 61.51 - Pilot logbooks.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Pilot logbooks. 61.51 Section 61.51... CERTIFICATION: PILOTS, FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS General § 61.51 Pilot logbooks. (a) Training... training device, or aviation training device, as appropriate. (v) The name of a safety pilot, if required...
14 CFR 61.51 - Pilot logbooks.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Pilot logbooks. 61.51 Section 61.51... CERTIFICATION: PILOTS, FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS General § 61.51 Pilot logbooks. (a) Training... training device, or aviation training device, as appropriate. (v) The name of a safety pilot, if required...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Termination of... acceptance of nominations for the Early Feasibility Study Investigational Device Exemption (IDE) Applications... technologies to participate in a pilot program for early feasibility study IDE applications. FDA is also...
Traffic Aware Planner for Cockpit-Based Trajectory Optimization
NASA Technical Reports Server (NTRS)
Woods, Sharon E.; Vivona, Robert A.; Henderson, Jeffrey; Wing, David J.; Burke, Kelly A.
2016-01-01
The Traffic Aware Planner (TAP) software application is a cockpit-based advisory tool designed to be hosted on an Electronic Flight Bag and to enable and test the NASA concept of Traffic Aware Strategic Aircrew Requests (TASAR). The TASAR concept provides pilots with optimized route changes (including altitude) that reduce fuel burn and/or flight time, avoid interactions with known traffic, weather and restricted airspace, and may be used by the pilots to request a route and/or altitude change from Air Traffic Control. Developed using an iterative process, TAP's latest improvements include human-machine interface design upgrades and added functionality based on the results of human-in-the-loop simulation experiments and flight trials. Architectural improvements have been implemented to prepare the system for operational-use trials with partner commercial airlines. Future iterations will enhance coordination with airline dispatch and add functionality to improve the acceptability of TAP-generated route-change requests to pilots, dispatchers, and air traffic controllers.
Examinations for leak tightness of actively cooled components in ITER and fusion devices
NASA Astrophysics Data System (ADS)
Hirai, T.; Barabash, V.; Carrat, R.; Chappuis, Ph; Durocher, A.; Escourbiac, F.; Merola, M.; Raffray, R.; Worth, L.; Boscary, J.; Chantant, M.; Chuilon, B.; Guilhem, D.; Hatchressian, J.-C.; Hong, S. H.; Kim, K. M.; Masuzaki, S.; Mogaki, K.; Nicolai, D.; Wilson, D.; Yao, D.
2017-12-01
Any leak in one of the ITER actively cooled components would cause significant consequences for machine operations; therefore, the risk of leak must be minimized as much as possible. In this paper, the strategy of examination to ensure leak tightness of the ITER internal components (i.e. examination of base materials, vacuum boundary joints and final components) and the hydraulic parameters for ITER internal components are summarized. The experiences of component tests, especially hot helium leak tests in recent fusion devices, were reviewed and the parameters were discussed. Through these experiences, it was confirmed that the hot He leak test was effective to detect small leak paths which were not always possible to detect by volumetric examination due to limited spatial resolution.
Interaction of adhered metallic dust with transient plasma heat loads
NASA Astrophysics Data System (ADS)
Ratynskaia, S.; Tolias, P.; Bykov, I.; Rudakov, D.; De Angeli, M.; Vignitchouk, L.; Ripamonti, D.; Riva, G.; Bardin, S.; van der Meiden, H.; Vernimmen, J.; Bystrov, K.; De Temmerman, G.
2016-06-01
The first study of the interaction of metallic dust (tungsten, aluminum) adhered on tungsten substrates with transient plasma heat loads is presented. Experiments were carried out in the Pilot-PSI linear device with transient heat fluxes up to 550 MW m-2 and in the DIII-D divertor tokamak. The central role of the dust-substrate contact area in heat conduction is highlighted and confirmed by heat transfer simulations. The experiments provide evidence of the occurrence of wetting-induced coagulation, a novel growth mechanism where cluster melting accompanied by droplet wetting leads to the formation of larger grains. The physical processes behind this mechanism are elucidated. The remobilization activity of the newly formed dust and the survivability of tungsten dust on hot surfaces are documented and discussed in the light of implications for ITER.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
...] International Medical Device Regulators Forum; Medical Device Single Audit Program International Coalition Pilot... Drug Administration (FDA) is announcing participation in the Medical Device Single Audit Program International Coalition Pilot Program. The Medical Device Single Audit Program (MDSAP) was designed and...
ERIC Educational Resources Information Center
Blundell, Shelley; Lambert, Frank
2014-01-01
In early spring 2013, a pilot study was conducted at a major public university in Ohio to explore elements of information anxiety (defined herein as a combination of library anxiety and information technology anxiety) among second-semester freshmen enrolled in all iterations of both a traditional and a remedial first-year English course. The…
Development of two color laser diagnostics for the ITER poloidal polarimeter.
Kawahata, K; Akiyama, T; Tanaka, K; Nakayama, K; Okajima, S
2010-10-01
Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 μm by using a twin optically pumped CH(3)OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.
Devine, Sharon; Bull, Sheana; Dreisbach, Susan; Shlay, Judith
2014-03-01
To develop and pilot a theory-based, mobile phone texting component attractive to minority youth as a supplement to the Teen Outreach Program(®), a youth development program for reducing teen pregnancy and school dropout. We conducted iterative formative research with minority youth in multiple focus groups to explore interest in texting and reaction to text messages. We piloted a month-long version of TOP(®) Plus Text with 96 teens at four sites and conducted a computer-based survey immediately after enrollment and at the end of the pilot that collected information about teens' values, social support, self-efficacy, and behaviors relating to school performance, trouble with the law, and sexual activity. After each of the first three weekly sessions we collected satisfaction measures. Upon completion of the pilot we conducted exit interviews with twelve purposively selected pilot participants. We successfully recruited and enrolled minority youth into the pilot. Teens were enthusiastic about text messages complementing TOP(®). Results also revealed barriers: access to text-capable mobile phones, retention as measured by completion of the post-pilot survey, and a need to be attentive to teen literacy. Piloting helped identify improvements for implementation including offering text messages through multiple platforms so youth without access to a mobile phone could receive messages; rewording texts to allow youth to express opinions without feeling judged; and collecting multiple types of contact information to improve follow-up. Thoughtful attention to social and behavioral theory and investment in iterative formative research with extensive consultation with teens can lead to an engaging texting curriculum that enhances and complements TOP(®). Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-23
...] Pilot Program for Early Feasibility Study Investigational Device Exemption Applications; Extending the... 13343), FDA terminated the acceptance of applications into the program and extended the pilot program for the nine accepted sponsors until May 8, 2013. The pilot program will be further extended for the...
2014-01-01
Background Sitting, particularly in prolonged, unbroken bouts, is widespread within the office workplace, yet few interventions have addressed this newly-identified health risk behaviour. This paper describes the iterative development process and resulting intervention procedures for the Stand Up Australia research program focusing on a multi-component workplace intervention to reduce sitting time. Methods The development of Stand Up Australia followed three phases. 1) Conceptualisation: Stand Up Australia was based on social cognitive theory and social ecological model components. These were operationalised via a taxonomy of intervention strategies and designed to target multiple levels of influence including: organisational structures (e.g. via management consultation), the physical work environment (via provision of height-adjustable workstations), and individual employees (e.g. via face-to-face coaching). 2) Formative research: Intervention components were separately tested for their feasibility and acceptability. 3) Pilot studies: Stand Up Comcare tested the integrated intervention elements in a controlled pilot study examining efficacy, feasibility and acceptability. Stand Up UQ examined the additional value of the organisational- and individual-level components over height-adjustable workstations only in a three-arm controlled trial. In both pilot studies, office workers’ sitting time was measured objectively using activPAL3 devices and the intervention was refined based on qualitative feedback from managers and employees. Results Results and feedback from participants and managers involved in the intervention development phases suggest high efficacy, acceptance, and feasibility of all intervention components. The final version of the Stand Up Australia intervention includes strategies at the organisational (senior management consultation, representatives consultation workshop, team champions, staff information and brainstorming session with information booklet, and supportive emails from managers to staff), environmental (height-adjustable workstations), and individual level (face-to-face coaching session and telephone support). Stand Up Australia is currently being evaluated in the context of a cluster-randomised controlled trial at the Department of Human Services (DHS) in Melbourne, Australia. Conclusions Stand Up Australia is an evidence-guided and systematically developed workplace intervention targeting reductions in office workers’ sitting time. PMID:24559162
Dynamic training devices in CRM training
NASA Technical Reports Server (NTRS)
Lawver, J.
1984-01-01
Pilot training effectiveness and flying safety of a seasonal tour flight company are described. The change from single pilot to two pilot operated twin otters is examined. The use of the ATC 810 training device, its possibilities and training capacity is outlined. Problem areas which may arise, emergency system and pilot/passenger interaction are analyzed.
Lessons from the pilot of a mobile application to map assistive technology suppliers in Africa.
Visagie, Surona J; Matter, Rebecca; Kayange, George M; Chiwaula, Mussa; Harniss, Mark; Mji, Gubela; Scheffler, Elsje
2018-01-01
A pilot project to develop and implement a mobile smartphone application (App) that tracks and maps assistive technology (AT) availability in southern Africa was launched in Botswana in 2016. The App was developed and tested through an iterative process. The concept of the App (AT-Info-Map) was well received by most stakeholders within the pilot country, and broader networks. Several technical and logistical obstacles were encountered. These included high data costs; difficulty in accessing AT information from the public healthcare sector, the largest supplier of AT; and the high human resource demand of collecting and keeping up-to-date device-level information within a complex and fragmented supply sector that spans private, public and civil society entities. The challenges were dealt with by keeping the data burden low and eliminating product-level tracking. The App design was expanded to include disability services, contextually specific AT categories and make navigation more intuitive. Long-term sustainability strategies like generating funding through advertisements on the App or supplier usage fees must be explored. Outreach and sensitisation programmes about both the App and AT in general must be intensified. The project team must continually strengthen partnerships with private and public stakeholders to ensure ongoing project engagement. The lessons learnt might be of value to others who wish to embark on initiatives in AT and/or implement Apps in health or disability in southern Africa and in low-resourced settings around the world.
Performance issues for iterative solvers in device simulation
NASA Technical Reports Server (NTRS)
Fan, Qing; Forsyth, P. A.; Mcmacken, J. R. F.; Tang, Wei-Pai
1994-01-01
Due to memory limitations, iterative methods have become the method of choice for large scale semiconductor device simulation. However, it is well known that these methods still suffer from reliability problems. The linear systems which appear in numerical simulation of semiconductor devices are notoriously ill-conditioned. In order to produce robust algorithms for practical problems, careful attention must be given to many implementation issues. This paper concentrates on strategies for developing robust preconditioners. In addition, effective data structures and convergence check issues are also discussed. These algorithms are compared with a standard direct sparse matrix solver on a variety of problems.
Suppression of tritium retention in remote areas of ITER by nonperturbative reactive gas injection.
Tabarés, F L; Ferreira, J A; Ramos, A; van Rooij, G; Westerhout, J; Al, R; Rapp, J; Drenik, A; Mozetic, M
2010-10-22
A technique based on reactive gas injection in the afterglow region of the divertor plasma is proposed for the suppression of tritium-carbon codeposits in remote areas of ITER when operated with carbon-based divertor targets. Experiments in a divertor simulator plasma device indicate that a 4 nm/min deposition can be suppressed by addition of 1 Pa·m³ s⁻¹ ammonia flow at 10 cm from the plasma. These results bolster the concept of nonperturbative scavenger injection for tritium inventory control in carbon-based fusion plasma devices, thus paving the way for ITER operation in the active phase under a carbon-dominated, plasma facing component background.
Phase III gross solids removal devices pilot study, 2002-2005.
DOT National Transportation Integrated Search
2005-12-01
The objective of the Phase III Gross Solids Removal Devices (GSRDs) Pilot study was to : evaluate the performance of non-proprietary devices that can capture gross solids and that can be : incorporated into existing highway drainage systems or implem...
Two-dimensional over-all neutronics analysis of the ITER device
NASA Astrophysics Data System (ADS)
Zimin, S.; Takatsu, Hideyuki; Mori, Seiji; Seki, Yasushi; Satoh, Satoshi; Tada, Eisuke; Maki, Koichi
1993-07-01
The present work attempts to carry out a comprehensive neutronics analysis of the International Thermonuclear Experimental Reactor (ITER) developed during the Conceptual Design Activities (CDA). The two-dimensional cylindrical over-all calculational models of ITER CDA device including the first wall, blanket, shield, vacuum vessel, magnets, cryostat and support structures were developed for this purpose with a help of the DOGII code. Two dimensional DOT 3.5 code with the FUSION-40 nuclear data library was employed for transport calculations of neutron and gamma ray fluxes, tritium breeding ratio (TBR), and nuclear heating in reactor components. The induced activity calculational code CINAC was employed for the calculations of exposure dose rate after reactor shutdown around the ITER CDA device. The two-dimensional over-all calculational model includes the design specifics such as the pebble bed Li2O/Be layered blanket, the thin double wall vacuum vessel, the concrete cryostat integrated with the over-all ITER design, the top maintenance shield plug, the additional ring biological shield placed under the top cryostat lid around the above-mentioned top maintenance shield plug etc. All the above-mentioned design specifics were included in the employed calculational models. Some alternative design options, such as the water-rich shielding blanket instead of lithium-bearing one, the additional biological shield plug at the top zone between the poloidal field (PF) coil No. 5, and the maintenance shield plug, were calculated as well. Much efforts have been focused on analyses of obtained results. These analyses aimed to obtain necessary recommendations on improving the ITER CDA design.
Progress in extrapolating divertor heat fluxes towards large fusion devices
NASA Astrophysics Data System (ADS)
Sieglin, B.; Faitsch, M.; Eich, T.; Herrmann, A.; Suttrop, W.; Collaborators, JET; the MST1 Team; the ASDEX Upgrade Team
2017-12-01
Heat load to the plasma facing components is one of the major challenges for the development and design of large fusion devices such as ITER. Nowadays fusion experiments can operate with heat load mitigation techniques, e.g. sweeping, impurity seeding, but do not generally require it. For large fusion devices however, heat load mitigation will be essential. This paper presents the current progress of the extrapolation of steady state and transient heat loads towards large fusion devices. For transient heat loads, so-called edge localized modes are considered a serious issue for the lifetime of divertor components. In this paper, the ITER operation at half field (2.65 T) and half current (7.5 MA) will be discussed considering the current material limit for the divertor peak energy fluence of 0.5 {MJ}/{{{m}}}2. Recent studies were successful in describing the observed energy fluence in the JET, MAST and ASDEX Upgrade using the pedestal pressure prior to the ELM crash. Extrapolating this towards ITER results in a more benign heat load compared to previous scalings. In the presence of magnetic perturbation, the axisymmetry is broken and a 2D heat flux pattern is induced on the divertor target, leading to local increase of the heat flux which is a concern for ITER. It is shown that for a moderate divertor broadening S/{λ }{{q}}> 0.5 the toroidal peaking of the heat flux disappears.
Iterative Methods to Solve Linear RF Fields in Hot Plasma
NASA Astrophysics Data System (ADS)
Spencer, Joseph; Svidzinski, Vladimir; Evstatiev, Evstati; Galkin, Sergei; Kim, Jin-Soo
2014-10-01
Most magnetic plasma confinement devices use radio frequency (RF) waves for current drive and/or heating. Numerical modeling of RF fields is an important part of performance analysis of such devices and a predictive tool aiding design and development of future devices. Prior attempts at this modeling have mostly used direct solvers to solve the formulated linear equations. Full wave modeling of RF fields in hot plasma with 3D nonuniformities is mostly prohibited, with memory demands of a direct solver placing a significant limitation on spatial resolution. Iterative methods can significantly increase spatial resolution. We explore the feasibility of using iterative methods in 3D full wave modeling. The linear wave equation is formulated using two approaches: for cold plasmas the local cold plasma dielectric tensor is used (resolving resonances by particle collisions), while for hot plasmas the conductivity kernel (which includes a nonlocal dielectric response) is calculated by integrating along test particle orbits. The wave equation is discretized using a finite difference approach. The initial guess is important in iterative methods, and we examine different initial guesses including the solution to the cold plasma wave equation. Work is supported by the U.S. DOE SBIR program.
Phase IV gross solids removal devices pilot study, 2004-2005.
DOT National Transportation Integrated Search
2005-12-01
The objective of the Phase IV Gross Solids Removal Device (GSRD) Pilot study was to evaluate : the performance of one non-proprietary device that can capture gross solids and that can be : incorporated into existing highway drainage systems or implem...
Novel aspects of plasma control in ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humphreys, D.; Jackson, G.; Walker, M.
2015-02-15
ITER plasma control design solutions and performance requirements are strongly driven by its nuclear mission, aggressive commissioning constraints, and limited number of operational discharges. In addition, high plasma energy content, heat fluxes, neutron fluxes, and very long pulse operation place novel demands on control performance in many areas ranging from plasma boundary and divertor regulation to plasma kinetics and stability control. Both commissioning and experimental operations schedules provide limited time for tuning of control algorithms relative to operating devices. Although many aspects of the control solutions required by ITER have been well-demonstrated in present devices and even designed satisfactorily formore » ITER application, many elements unique to ITER including various crucial integration issues are presently under development. We describe selected novel aspects of plasma control in ITER, identifying unique parts of the control problem and highlighting some key areas of research remaining. Novel control areas described include control physics understanding (e.g., current profile regulation, tearing mode (TM) suppression), control mathematics (e.g., algorithmic and simulation approaches to high confidence robust performance), and integration solutions (e.g., methods for management of highly subscribed control resources). We identify unique aspects of the ITER TM suppression scheme, which will pulse gyrotrons to drive current within a magnetic island, and turn the drive off following suppression in order to minimize use of auxiliary power and maximize fusion gain. The potential role of active current profile control and approaches to design in ITER are discussed. Issues and approaches to fault handling algorithms are described, along with novel aspects of actuator sharing in ITER.« less
Novel aspects of plasma control in ITER
Humphreys, David; Ambrosino, G.; de Vries, Peter; ...
2015-02-12
ITER plasma control design solutions and performance requirements are strongly driven by its nuclear mission, aggressive commissioning constraints, and limited number of operational discharges. In addition, high plasma energy content, heat fluxes, neutron fluxes, and very long pulse operation place novel demands on control performance in many areas ranging from plasma boundary and divertor regulation to plasma kinetics and stability control. Both commissioning and experimental operations schedules provide limited time for tuning of control algorithms relative to operating devices. Although many aspects of the control solutions required by ITER have been well-demonstrated in present devices and even designed satisfactorily formore » ITER application, many elements unique to ITER including various crucial integration issues are presently under development. We describe selected novel aspects of plasma control in ITER, identifying unique parts of the control problem and highlighting some key areas of research remaining. Novel control areas described include control physics understanding (e.g. current profile regulation, tearing mode suppression (TM)), control mathematics (e.g. algorithmic and simulation approaches to high confidence robust performance), and integration solutions (e.g. methods for management of highly-subscribed control resources). We identify unique aspects of the ITER TM suppression scheme, which will pulse gyrotrons to drive current within a magnetic island, and turn the drive off following suppression in order to minimize use of auxiliary power and maximize fusion gain. The potential role of active current profile control and approaches to design in ITER are discussed. Finally, issues and approaches to fault handling algorithms are described, along with novel aspects of actuator sharing in ITER.« less
Scoping study for compact high-field superconducting net energy tokamaks
NASA Astrophysics Data System (ADS)
Mumgaard, R. T.; Greenwald, M.; Freidberg, J. P.; Wolfe, S. M.; Hartwig, Z. S.; Brunner, D.; Sorbom, B. N.; Whyte, D. G.
2016-10-01
The continued development and commercialization of high temperature superconductors (HTS) may enable the construction of compact, net-energy tokamaks. HTS, in contrast to present generation low temperature superconductors, offers improved performance in high magnetic fields, higher current density, stronger materials, higher temperature operation, and simplified assembly. Using HTS along with community-consensus confinement physics (H98 =1) may make it possible to achieve net-energy (Q>1) or burning plasma conditions (Q>5) in DIII-D or ASDEX-U sized, conventional aspect ratio tokamaks. It is shown that, by operating at high plasma current and density enabled by the high magnetic field (B>10T), the required triple products may be achieved at plasma volumes under 20m3, major radii under 2m, with external heating powers under 40MW. This is at the scale of existing devices operated by laboratories, universities and companies. The trade-offs in the core heating, divertor heat exhaust, sustainment, stability, and proximity to known plasma physics limits are discussed in the context of the present tokamak experience base and the requirements for future devices. The resulting HTS-based design space is compared and contrasted to previous studies on high-field copper experiments with similar missions. The physics exploration conducted with such HTS devices could decrease the real and perceived risks of ITER exploitation, and aid in quickly developing commercially-applicable tokamak pilot plants and reactors.
Development of a practice-based research program.
Hawk, C; Long, C R; Boulanger, K
1998-01-01
To establish an infrastructure to collect accurate data from ambulatory settings. The program was developed through an iterative model governed by a process of formative evaluation. The three iterations were a needs assessment, feasibility study and pilot project. Necessary program components were identified as infrastructure, practitioner-researcher partnership, centralized data management and standardized quality assurance measures. Volunteer chiropractors and their staff collected data on patients in their practices in ambulatory settings in the U.S. and Canada. Evaluative measures were counts of participants, patients and completed forms. Standardized, validated and reliable measures collected by patient self-report were used to assess treatment outcomes. These included the SF-36 or SF-12 Health Survey, the Pain Disability Index, and the Global Well-Being Scale. For characteristics for which appropriate standardized instruments were not available, questionnaires were designed and and pilot-tested before use. Information was gathered on practice and patient characteristics and treatment outcomes, but for this report, only those data concerning process evaluation are reported. Through the three program iterations, 65 DCs collected data on 1360 patients, 663 of whom were new patients. Follow-up data recorded by doctors were obtained for more than 70% of patients; a maximum of 50% of patient-completed follow-up forms were collected in the three iterations. This program is capable of providing data for descriptive epidemiology of ambulatory patients, and, with continued effort to maximize follow-up, may have utility in providing insight into utilization patterns and patient outcomes.
Gartrell, Kyungsook; Brennan, Caitlin W; Wallen, Gwenyth R; Liu, Fang; Smith, Karen G; Fontelo, Paul
2018-05-08
Although evidence-based practice in healthcare has been facilitated by Internet access through wireless mobile devices, research on the effectiveness of clinical decision support for clinicians at the point of care is lacking. This study examined how evidence as abstracts and the bottom-line summaries, accessed with PubMed4Hh mobile devices, affected clinicians' decision making at the point of care. Three iterative steps were taken to evaluate the usefulness of PubMed4Hh tools at the NIH Clinical Center. First, feasibility testing was conducted using data collected from a librarian. Next, usability testing was carried out by a postdoctoral research fellow shadowing clinicians during rounds for one month in the inpatient setting. Then, a pilot study was conducted from February, 2016 to January, 2017, with clinicians using a mobile version of PubMed4Hh. Invitations were sent via e-mail lists to clinicians (physicians, physician assistants and nurse practitioners) along with periodic reminders. Participants rated the usefulness of retrieved bottom-line summaries and abstracts and indicated their usefulness on a 7-point Likert scale. They also indicated location of use (office, rounds, etc.). Of the 166 responses collected in the feasibility phase, more than half of questions (57%, n = 94) were answerable by both the librarian using various resources and by the postdoctoral research fellow using PubMed4Hh. Sixty-six questions were collected during usability testing. More than half of questions (60.6%) were related to information about medication or treatment, while 21% were questions regarding diagnosis, and 12% were specific to disease entities. During the pilot study, participants reviewed 34 abstracts and 40 bottom-line summaries. The abstracts' usefulness mean scores were higher (95% CI [6.12, 6.64) than the scores of the bottom-line summaries (95% CI [5.25, 6.10]). The most frequent reason given was that it confirmed current or tentative diagnostic or treatment plan. The bottom-line summaries were used more in the office (79.3%), and abstracts were used more at point of care (51.9%). Clinicians reported that retrieving relevant health information from biomedical literature using the PubMed4Hh was useful at the point of care and in the office.
The Roles and Developments needed for Diagnostics in the ITER Fusion Device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walsh, Michael
2015-07-01
Harnessing the power from Fusion on earth is an important and challenging task. Excellent work has been carried out in this area over the years with several demonstrations of the ability to produce power. Now, a new large device is being constructed in the south of France. This is called ITER. ITER is a large-scale scientific experiment that aims to demonstrate a possibility to produce commercial energy from fusion. This project is now well underway with the many teams working on the construction and completing various aspects of the design. This device will carry up to 15 MA of plasmamore » current and produce about 500 MW of power, 400 MW approximately in high energy neutrons. The typical temperatures of the electrons inside this device are in the region of a few hundred million Kelvin. It is maintained using a magnetic field. This device is pushing several boundaries from those currently existing. As a result of this, several technologies need to be developed or extended. This is especially true for the systems or diagnostics that measure the performance and provide the control signals for this device. A diagnostic set will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include amongst others, measurements of the plasma shape, temperature, density, impurity concentration, and particle and energy confinement times. The system will comprise about 45 individual measuring systems drawn from the full range of modern plasma diagnostic techniques, including magnetics, lasers, X-rays, neutron cameras, impurity monitors, particle spectrometers, radiation bolometers, pressure and gas analysis, and optical fibres. These devices will have to be made to work in the new and challenging environment inside the vacuum vessel. These systems will have to cope with a range of phenomena that extend the current knowledge in the Fusion field. One amongst them is the parasitic effect of the neutrons on the while all the performing with great accuracy and precision. The levels of neutral particle flux, neutron flux and neutron fluence will be respectively about 5, 10 and 10,000 times higher than the harshest experienced in today's machines. The pulse length of the fusion reaction-or the amount of time the reaction is sustained-will be about 100 times longer. (authors)« less
Conte, Marisa L.; MacEachern, Mark P.; Mani, Nandita S.; Townsend, Whitney A.; Smith, Judith E.; Masters, Chase; Kelley, Caitlin
2015-01-01
Objective: The researchers used the flipped classroom model to develop and conduct a systematic review course for librarians. Setting: The research took place at an academic health sciences library. Method: A team of informationists developed and conducted a pilot course. Assessment informed changes to both course components; a second course addressed gaps in the pilot. Main Results: Both the pilot and subsequent course received positive reviews. Changes based on assessment data will inform future iterations. Conclusion: The flipped classroom model can be successful in developing and implementing a course that is well rated by students. PMID:25918484
Naidu, Sailen G; Kriegshauser, J Scott; Paden, Robert G; He, Miao; Wu, Qing; Hara, Amy K
2014-12-01
An ultra-low-dose radiation protocol reconstructed with model-based iterative reconstruction was compared with our standard-dose protocol. This prospective study evaluated 20 men undergoing surveillance-enhanced computed tomography after endovascular aneurysm repair. All patients underwent standard-dose and ultra-low-dose venous phase imaging; images were compared after reconstruction with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction. Objective measures of aortic contrast attenuation and image noise were averaged. Images were subjectively assessed (1 = worst, 5 = best) for diagnostic confidence, image noise, and vessel sharpness. Aneurysm sac diameter and endoleak detection were compared. Quantitative image noise was 26% less with ultra-low-dose model-based iterative reconstruction than with standard-dose adaptive statistical iterative reconstruction and 58% less than with ultra-low-dose adaptive statistical iterative reconstruction. Average subjective noise scores were not different between ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction (3.8 vs. 4.0, P = .25). Subjective scores for diagnostic confidence were better with standard-dose adaptive statistical iterative reconstruction than with ultra-low-dose model-based iterative reconstruction (4.4 vs. 4.0, P = .002). Vessel sharpness was decreased with ultra-low-dose model-based iterative reconstruction compared with standard-dose adaptive statistical iterative reconstruction (3.3 vs. 4.1, P < .0001). Ultra-low-dose model-based iterative reconstruction and standard-dose adaptive statistical iterative reconstruction aneurysm sac diameters were not significantly different (4.9 vs. 4.9 cm); concordance for the presence of endoleak was 100% (P < .001). Compared with a standard-dose technique, an ultra-low-dose model-based iterative reconstruction protocol provides comparable image quality and diagnostic assessment at a 73% lower radiation dose.
Adaptive Management for Urban Watersheds: The Slavic Village Pilot Project
Adaptive management is an environmental management strategy that uses an iterative process of decision-making to reduce the uncertainty in environmental management via system monitoring. A central tenet of adaptive management is that management involves a learning process that ca...
Efficient design of nanoplasmonic waveguide devices using the space mapping algorithm.
Dastmalchi, Pouya; Veronis, Georgios
2013-12-30
We show that the space mapping algorithm, originally developed for microwave circuit optimization, can enable the efficient design of nanoplasmonic waveguide devices which satisfy a set of desired specifications. Space mapping utilizes a physics-based coarse model to approximate a fine model accurately describing a device. Here the fine model is a full-wave finite-difference frequency-domain (FDFD) simulation of the device, while the coarse model is based on transmission line theory. We demonstrate that simply optimizing the transmission line model of the device is not enough to obtain a device which satisfies all the required design specifications. On the other hand, when the iterative space mapping algorithm is used, it converges fast to a design which meets all the specifications. In addition, full-wave FDFD simulations of only a few candidate structures are required before the iterative process is terminated. Use of the space mapping algorithm therefore results in large reductions in the required computation time when compared to any direct optimization method of the fine FDFD model.
NASA Technical Reports Server (NTRS)
Chelette, T. L.; Repperger, Daniel W.; Albery, W. B.
1991-01-01
An effort was initiated at the Armstrong Aerospace Medical Research Laboratory (AAMRL) to investigate the improvement of the situational awareness of a pilot with respect to his aircraft's spatial orientation. The end product of this study is a device to alert a pilot to potentially disorienting situations. Much like a ground collision avoidance system (GCAS) is used in fighter aircraft to alert the pilot to 'pull up' when dangerous flight paths are predicted, this device warns the pilot to put a higher priority on attention to the orientation instrument. A Kalman filter was developed which estimates the pilot's perceived position and orientation. The input to the Kalman filter consists of two classes of data. The first class of data consists of noise parameters (indicating parameter uncertainty), conflict signals (e.g. vestibular and kinesthetic signal disagreement), and some nonlinear effects. The Kalman filter's perceived estimates are now the sum of both Class 1 data (good information) and Class 2 data (distorted information). When the estimated perceived position or orientation is significantly different from the actual position or orientation, the pilot is alerted.
NASA Astrophysics Data System (ADS)
Sanz, D.; Ruiz, M.; Castro, R.; Vega, J.; Afif, M.; Monroe, M.; Simrock, S.; Debelle, T.; Marawar, R.; Glass, B.
2016-04-01
To aid in assessing the functional performance of ITER, Fission Chambers (FC) based on the neutron diagnostic use case deliver timestamped measurements of neutron source strength and fusion power. To demonstrate the Plant System Instrumentation & Control (I&C) required for such a system, ITER Organization (IO) has developed a neutron diagnostics use case that fully complies with guidelines presented in the Plant Control Design Handbook (PCDH). The implementation presented in this paper has been developed on the PXI Express (PXIe) platform using products from the ITER catalog of standard I&C hardware for fast controllers. Using FlexRIO technology, detector signals are acquired at 125 MS/s, while filtering, decimation, and three methods of neutron counting are performed in real-time via the onboard Field Programmable Gate Array (FPGA). Measurement results are reported every 1 ms through Experimental Physics and Industrial Control System (EPICS) Channel Access (CA), with real-time timestamps derived from the ITER Timing Communication Network (TCN) based on IEEE 1588-2008. Furthermore, in accordance with ITER specifications for CODAC Core System (CCS) application development, the software responsible for the management, configuration, and monitoring of system devices has been developed in compliance with a new EPICS module called Nominal Device Support (NDS) and RIO/FlexRIO design methodology.
Integrating Virtual Worlds with Tangible User Interfaces for Teaching Mathematics: A Pilot Study.
Guerrero, Graciela; Ayala, Andrés; Mateu, Juan; Casades, Laura; Alamán, Xavier
2016-10-25
This article presents a pilot study of the use of two new tangible interfaces and virtual worlds for teaching geometry in a secondary school. The first tangible device allows the user to control a virtual object in six degrees of freedom. The second tangible device is used to modify virtual objects, changing attributes such as position, size, rotation and color. A pilot study on using these devices was carried out at the "Florida Secundaria" high school. A virtual world was built where students used the tangible interfaces to manipulate geometrical figures in order to learn different geometrical concepts. The pilot experiment results suggest that the use of tangible interfaces and virtual worlds allowed a more meaningful learning (concepts learnt were more durable).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos, Bruno; Carvalho, Paulo F.; Rodrigues, A.P.
The ATCA standard specifies a mandatory Shelf Manager (ShM) unit which is a key element for the system operation. It includes the Intelligent Platform Management Controller (IPMC) which monitors the system health, retrieves inventory information and controls the Field Replaceable Units (FRUs). These elements enable the intelligent health monitoring, providing high-availability and safety operation, ensuring the correct system operation. For critical systems like ones of tokamak ITER these features are mandatory to support the long pulse operation. The Nominal Device Support (NDS) was designed and developed for the ITER CODAC Core System (CCS), which will be the responsible for plantmore » Instrumentation and Control (I and C), supervising and monitoring on ITER. It generalizes the Enhanced Physics and Industrial Control System (EPICS) device support interface for Data Acquisition (DAQ) and timing devices. However the support for health management features and ATCA ShM are not yet provided. This paper presents the implementation and test of a NDS for the ATCA ShM, using the ITER Fast Plant System Controller (FPSC) prototype environment. This prototype is fully compatible with the ITER CCS and uses the EPICS Channel Access (CA) protocol as the interface with the Plant Operation Network (PON). The implemented solution running in an EPICS Input / Output Controller (IOC) provides Process Variables (PV) to the PON network with the system information. These PVs can be used for control and monitoring by all CA clients, such as EPICS user interface clients and alarm systems. The results are presented, demonstrating the fully integration and the usability of this solution. (authors)« less
Seon, C R; Choi, S H; Cheon, M S; Pak, S; Lee, H G; Biel, W; Barnsley, R
2010-10-01
A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.
Developing and Pilot Testing a Spanish Translation of CollaboRATE for Use in the United States.
Forcino, Rachel C; Bustamante, Nitzy; Thompson, Rachel; Percac-Lima, Sanja; Elwyn, Glyn; Pérez-Arechaederra, Diana; Barr, Paul J
2016-01-01
Given the need for access to patient-facing materials in multiple languages, this study aimed to develop and pilot test an accurate and understandable translation of CollaboRATE, a three-item patient-reported measure of shared decision-making, for Spanish-speaking patients in the United States (US). We followed the Translate, Review, Adjudicate, Pre-test, Document (TRAPD) survey translation protocol. Cognitive interviews were conducted with Spanish-speaking adults within an urban Massachusetts internal medicine clinic. For the pilot test, all patients with weekday appointments between May 1 and May 29, 2015 were invited to complete CollaboRATE in either English or Spanish upon exit. We calculated the proportion of respondents giving the best score possible on CollaboRATE and compared scores across key patient subgroups. Four rounds of cognitive interviews with 26 people were completed between January and April 2015. Extensive, iterative refinements to survey items between interview rounds led to final items that were generally understood by participants with diverse educational backgrounds. Pilot data collection achieved an overall response rate of 73 percent, with 606 (49%) patients completing Spanish CollaboRATE questionnaires and 624 (51%) patients completing English CollaboRATE questionnaires. The proportion of respondents giving the best score possible on CollaboRATE was the same (86%) for both the English and Spanish versions of the instrument. Our translation method, guided by emerging best practices in survey and health measurement translation, encompassed multiple levels of review. By conducting four rounds of cognitive interviews with iterative item refinement between each round, we arrived at a Spanish language version of CollaboRATE that was understandable to a majority of cognitive interview participants and was completed by more than 600 pilot questionnaire respondents.
de Vries, Peter C.; Luce, Timothy C.; Bae, Young-soon; ...
2017-11-22
To improve our understanding of the dynamics and control of ITER terminations, a study has been carried out on data from existing tokamaks. The aim of this joint analysis is to compare the assumptions for ITER terminations with the present experience basis. The study examined the parameter ranges in which present day devices operated during their terminations, as well as the dynamics of these parameters. The analysis of a database, built using a selected set of experimental termination cases, showed that, the H-mode density decays slower than the plasma current ramp-down. The consequential increase in fGW limits the duration ofmore » the H-mode phase or result in disruptions. The lower temperatures after the drop out of H-mode will allow the plasma internal inductance to increase. But vertical stability control remains manageable in ITER at high internal inductance when accompanied by a strong elongation reduction. This will result in ITER terminations remaining longer at low q (q95~3) than most present-day devices during the current ramp-down. A fast power ramp-down leads to a larger change in βp at the H-L transition, but the experimental data showed that these are manageable for the ITER radial position control. The analysis of JET data shows that radiation and impurity levels significantly alter the H-L transition dynamics. Self-consistent calculations of the impurity content and resulting radiation should be taken into account when modelling ITER termination scenarios. Here, the results from this analysis can be used to better prescribe the inputs for the detailed modelling and preparation of ITER termination scenarios.« less
NASA Astrophysics Data System (ADS)
de Vries, P. C.; Luce, T. C.; Bae, Y. S.; Gerhardt, S.; Gong, X.; Gribov, Y.; Humphreys, D.; Kavin, A.; Khayrutdinov, R. R.; Kessel, C.; Kim, S. H.; Loarte, A.; Lukash, V. E.; de la Luna, E.; Nunes, I.; Poli, F.; Qian, J.; Reinke, M.; Sauter, O.; Sips, A. C. C.; Snipes, J. A.; Stober, J.; Treutterer, W.; Teplukhina, A. A.; Voitsekhovitch, I.; Woo, M. H.; Wolfe, S.; Zabeo, L.; the Alcator C-MOD Team; the ASDEX Upgrade Team; the DIII-D Team; the EAST Team; contributors, JET; the KSTAR Team; the NSTX-U Team; the TCV Team; IOS members, ITPA; experts
2018-02-01
To improve our understanding of the dynamics and control of ITER terminations, a study has been carried out on data from existing tokamaks. The aim of this joint analysis is to compare the assumptions for ITER terminations with the present experience basis. The study examined the parameter ranges in which present day devices operated during their terminations, as well as the dynamics of these parameters. The analysis of a database, built using a selected set of experimental termination cases, showed that, the H-mode density decays slower than the plasma current ramp-down. The consequential increase in f GW limits the duration of the H-mode phase or result in disruptions. The lower temperatures after the drop out of H-mode will allow the plasma internal inductance to increase. But vertical stability control remains manageable in ITER at high internal inductance when accompanied by a strong elongation reduction. This will result in ITER terminations remaining longer at low q (q 95 ~ 3) than most present-day devices during the current ramp-down. A fast power ramp-down leads to a larger change in β p at the H-L transition, but the experimental data showed that these are manageable for the ITER radial position control. The analysis of JET data shows that radiation and impurity levels significantly alter the H-L transition dynamics. Self-consistent calculations of the impurity content and resulting radiation should be taken into account when modelling ITER termination scenarios. The results from this analysis can be used to better prescribe the inputs for the detailed modelling and preparation of ITER termination scenarios.
Mixed plasma species effects on Tungsten
NASA Astrophysics Data System (ADS)
Baldwin, Matt; Doerner, Russ; Nishijima, Daisuke; Ueda, Yoshio
2007-11-01
The diverted reactor exhaust in confinement machines like ITER and DEMO will be intense-mixed plasmas of fusion (D, T, He) and wall species (Be, C, W, in ITER and W in DEMO), characterized by tremendous heat and particle fluxes. In both devices, the divertor walls are to be exposed to such plasma and must operate at high temperature for long durations. Tungsten, with its high-melting point and low-sputtering yield is currently viewed as the leading choice for divertor-wall material in this next generation class of fusion devices, and is supported by an enormous amount of work that has been done to examine its performance in hydrogen isotope plasmas. However, studies of the more realistic scenario, involving mixed species interactions, are considerably less. Current experiments on the PISCES-B device are focused on these issues. The formation of Be-W alloys, He induced nanoscopic morphology, and blistering, as well as mitigation influences on these effects caused by Be and C layer formation have all been observed. These results and the corresponding implications for ITER and DEMO will be presented.
Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab
2018-01-01
Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood pressure measurements. Conclusions The systolic pressure measurements of the wrist cuff have been iteratively calibrated using gold standard central (ascending aortic) pressure. This improves the accuracy of the indirect measures and potentially reduces the treatment gap. Devices that undergo auscultatory (indirect) calibration for licensing can be greatly improved by additional iterative calibration via intra-arterial (direct) measures of blood pressure. Further clinical trials with repeated use of the device over time are needed to assess the reliability of the device in accordance with current and evolving guidelines for informed decision making in the management of hypertension. Trial Registration ClinicalTrials.gov NCT03015363; https://clinicaltrials.gov/ct2/show/NCT03015363 (Archived by WebCite at http://www.webcitation.org/6xPZgseYS) PMID:29695375
OVERVIEW OF NEUTRON MEASUREMENTS IN JET FUSION DEVICE.
Batistoni, P; Villari, R; Obryk, B; Packer, L W; Stamatelatos, I E; Popovichev, S; Colangeli, A; Colling, B; Fonnesu, N; Loreti, S; Klix, A; Klosowski, M; Malik, K; Naish, J; Pillon, M; Vasilopoulou, T; De Felice, P; Pimpinella, M; Quintieri, L
2017-10-05
The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium-tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Design optimization of first wall and breeder unit module size for the Indian HCCB blanket module
NASA Astrophysics Data System (ADS)
Deepak, SHARMA; Paritosh, CHAUDHURI
2018-04-01
The Indian test blanket module (TBM) program in ITER is one of the major steps in the Indian fusion reactor program for carrying out the R&D activities in the critical areas like design of tritium breeding blankets relevant to future Indian fusion devices (ITER relevant and DEMO). The Indian Lead–Lithium Cooled Ceramic Breeder (LLCB) blanket concept is one of the Indian DEMO relevant TBM, to be tested in ITER as a part of the TBM program. Helium-Cooled Ceramic Breeder (HCCB) is an alternative blanket concept that consists of lithium titanate (Li2TiO3) as ceramic breeder (CB) material in the form of packed pebble beds and beryllium as the neutron multiplier. Specifically, attentions are given to the optimization of first wall coolant channel design and size of breeder unit module considering coolant pressure and thermal loads for the proposed Indian HCCB blanket based on ITER relevant TBM and loading conditions. These analyses will help proceeding further in designing blankets for loads relevant to the future fusion device.
An overview of ITER diagnostics (invited)
NASA Astrophysics Data System (ADS)
Young, Kenneth M.; Costley, A. E.; ITER-JCT Home Team; ITER Diagnostics Expert Group
1997-01-01
The requirements for plasma measurements for operating and controlling the ITER device have now been determined. Initial criteria for the measurement quality have been set, and the diagnostics that might be expected to achieve these criteria have been chosen. The design of the first set of diagnostics to achieve these goals is now well under way. The design effort is concentrating on the components that interact most strongly with the other ITER systems, particularly the vacuum vessel, blankets, divertor modules, cryostat, and shield wall. The relevant details of the ITER device and facility design and specific examples of diagnostic design to provide the necessary measurements are described. These designs have to take account of the issues associated with very high 14 MeV neutron fluxes and fluences, nuclear heating, high heat loads, and high mechanical forces that can arise during disruptions. The design work is supported by an extensive research and development program, which to date has concentrated on the effects these levels of radiation might cause on diagnostic components. A brief outline of the organization of the diagnostic development program is given.
14 CFR 61.167 - Airline transport pilot privileges and limitations.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) In flight simulators, and flight training devices representing the aircraft referenced in paragraph... instruct in aircraft, flight simulators, and flight training devices under this section— (i) For more than... TRANSPORTATION (CONTINUED) AIRMEN CERTIFICATION: PILOTS, FLIGHT INSTRUCTORS, AND GROUND INSTRUCTORS Airline...
Integrating Virtual Worlds with Tangible User Interfaces for Teaching Mathematics: A Pilot Study
Guerrero, Graciela; Ayala, Andrés; Mateu, Juan; Casades, Laura; Alamán, Xavier
2016-01-01
This article presents a pilot study of the use of two new tangible interfaces and virtual worlds for teaching geometry in a secondary school. The first tangible device allows the user to control a virtual object in six degrees of freedom. The second tangible device is used to modify virtual objects, changing attributes such as position, size, rotation and color. A pilot study on using these devices was carried out at the “Florida Secundaria” high school. A virtual world was built where students used the tangible interfaces to manipulate geometrical figures in order to learn different geometrical concepts. The pilot experiment results suggest that the use of tangible interfaces and virtual worlds allowed a more meaningful learning (concepts learnt were more durable). PMID:27792132
Demonstration of an Ice Contamination Effects Flight Training Device
NASA Technical Reports Server (NTRS)
Ratvasky, Thomas P.; Ranaudo, Richard J.; Blankenship, Kurt S.; Lee, Sam
2006-01-01
The development of a piloted flight simulator called the Ice Contamination Effects Flight Training Device (ICEFTD) was recently completed. This device demonstrates the ability to accurately represent an iced airplane s flight characteristics and is utilized to train pilots in recognizing and recovering from aircraft handling anomalies that result from airframe ice formations. The ICEFTD was demonstrated at three recent short courses hosted by the University of Tennessee Space Institute. It was also demonstrated to a group of pilots at the National Test Pilot School. In total, eighty-four pilots and flight test engineers from industry and the regulatory community spent approximately one hour each in the ICEFTD to get a "hands on" lesson of an iced airplane s reduced performance and handling qualities. Additionally, pilot cues of impending upsets and recovery techniques were demonstrated. The purpose of this training was to help pilots understand how ice contamination affects aircraft handling so they may apply that knowledge to the operations of other aircraft undergoing testing and development. Participant feedback on the ICEFTD was very positive. Pilots stated that the simulation was very valuable, applicable to their occupations, and provided a safe way to explore the flight envelope. Feedback collected at each demonstration was also helpful to define additional improvements to the ICEFTD; many of which were then implemented in subsequent demonstrations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomquist, Heidi K.; Fixel, Deborah A.; Fett, David Brian
The Xyce Parallel Electronic Simulator simulates electronic circuit behavior in DC, AC, HB, MPDE and transient mode using standard analog (DAE) and/or device (PDE) device models including several age and radiation aware devices. It supports a variety of computing platforms (both serial and parallel) computers. Lastly, it uses a variety of modern solution algorithms dynamic parallel load-balancing and iterative solvers.
Preliminary consideration of CFETR ITER-like case diagnostic system.
Li, G S; Yang, Y; Wang, Y M; Ming, T F; Han, X; Liu, S C; Wang, E H; Liu, Y K; Yang, W J; Li, G Q; Hu, Q S; Gao, X
2016-11-01
Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basic control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.
Preliminary consideration of CFETR ITER-like case diagnostic system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, G. S.; Liu, Y. K.; Gao, X.
2016-11-15
Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basicmore » control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.« less
Progress in Development of the ITER Plasma Control System Simulation Platform
NASA Astrophysics Data System (ADS)
Walker, Michael; Humphreys, David; Sammuli, Brian; Ambrosino, Giuseppe; de Tommasi, Gianmaria; Mattei, Massimiliano; Raupp, Gerhard; Treutterer, Wolfgang; Winter, Axel
2017-10-01
We report on progress made and expected uses of the Plasma Control System Simulation Platform (PCSSP), the primary test environment for development of the ITER Plasma Control System (PCS). PCSSP will be used for verification and validation of the ITER PCS Final Design for First Plasma, to be completed in 2020. We discuss the objectives of PCSSP, its overall structure, selected features, application to existing devices, and expected evolution over the lifetime of the ITER PCS. We describe an archiving solution for simulation results, methods for incorporating physics models of the plasma and physical plant (tokamak, actuator, and diagnostic systems) into PCSSP, and defining characteristics of models suitable for a plasma control development environment such as PCSSP. Applications of PCSSP simulation models including resistive plasma equilibrium evolution are demonstrated. PCSSP development supported by ITER Organization under ITER/CTS/6000000037. Resistive evolution code developed under General Atomics' Internal funding. The views and opinions expressed herein do not necessarily reflect those of the ITER Organization.
14 CFR 141.41 - Flight simulators, flight training devices, and training aids.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., and training aids. 141.41 Section 141.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aids. An applicant for a pilot school certificate or a provisional pilot school certificate must show that its flight simulators, flight training devices, training aids, and equipment meet the following...
14 CFR 141.41 - Flight simulators, flight training devices, and training aids.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., and training aids. 141.41 Section 141.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aids. An applicant for a pilot school certificate or a provisional pilot school certificate must show that its flight simulators, flight training devices, training aids, and equipment meet the following...
14 CFR 141.41 - Flight simulators, flight training devices, and training aids.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., and training aids. 141.41 Section 141.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aids. An applicant for a pilot school certificate or a provisional pilot school certificate must show that its flight simulators, flight training devices, training aids, and equipment meet the following...
14 CFR 141.41 - Flight simulators, flight training devices, and training aids.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., and training aids. 141.41 Section 141.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aids. An applicant for a pilot school certificate or a provisional pilot school certificate must show that its flight simulators, flight training devices, training aids, and equipment meet the following...
77 FR 18793 - Spectrum Sharing Innovation Test-Bed Pilot Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-28
.... 120322212-2212-01] Spectrum Sharing Innovation Test-Bed Pilot Program AGENCY: National Telecommunications... Innovation Test-Bed pilot program to assess whether devices employing Dynamic Spectrum Access techniques can... Spectrum Sharing Innovation Test-Bed (Test-Bed) pilot program to examine the feasibility of increased...
Method of making a silicon nanowire device
None, None
2017-05-23
There is provided an electronic device and a method for its manufacture. The device comprises an elongate silicon nanowire less than 0.5 .mu.m in cross-sectional dimensions and having a hexagonal cross-sectional shape due to annealing-induced energy relaxation. The method, in examples, includes thinning the nanowire through iterative oxidation and etching of the oxidized portion.
Culturally Based Intervention Development: The Case of Latino Families Dealing with Schizophrenia
ERIC Educational Resources Information Center
Barrio, Concepcion; Yamada, Ann-Marie
2010-01-01
Objectives: This article describes the process of developing a culturally based family intervention for Spanish-speaking Latino families with a relative diagnosed with schizophrenia. Method: Our iterative intervention development process was guided by a cultural exchange framework and based on findings from an ethnographic study. We piloted this…
Gopal, Anand D; Rathi, Vinay K; Teng, Christopher C; Del Priore, Lucian; Ross, Joseph S
2017-08-01
To characterize the frequency, nature, and regulatory mechanisms by which ophthalmic devices are iteratively modified after initial Food and Drug Administration (FDA) Premarket Approval (PMA). Retrospective cross-sectional analysis using publicly available FDA data. Ophthalmic devices initially approved via the FDA's PMA pathway between January 1, 1979 and December 31, 2015. We used the FDA's PMA Database to identify and characterize initial approvals and subsequent postmarket modifications to Class III ophthalmic devices. The FDA Recalls Database was used to identify associated safety events. Median iterated life span (timespan across which modifications occurred after initial PMA) and median number of supplements approved per device, by device type, and overall, stratified by regulatory pathway and modification type. Between 1979 and 2015, the FDA approved 168 original ophthalmic devices via the PMA pathway and 2813 subsequent modifications. More than one third (n = 64; 38%) of original approvals were intraocular lenses. Overall, devices underwent a median of 11 postmarket modifications (interquartile range [IQR], 3-24.8) across a median 10.0-year iterated life span (IQR, 4.1-16.7). The majority of devices (n = 144; 86%) underwent more than 1 postapproval modification, including more than 1 design modification (n = 84; 50%). The median number of changes altering device design or labeling was 3.5 (IQR, 1-9). Although manufacturing alterations (n = 834 of 2813; 30%) were the most frequent type of revision, changes involving device design (n = 667; 24%) and labeling (n = 417; 15%) were common. Recalled devices underwent more frequent postapproval modifications per year (median, 1.4; IQR, 0.7-2.3; mean, 1.5; 95% confidence interval, 1.1-1.9) in the period preceding recall than did nonrecalled devices (median, 0.5; IQR, 0.2-1.1; mean, 0.8; 95% confidence interval, 0.7-1.0) across their market approval period (P < 0.001). Most ophthalmic devices approved via the FDA's PMA pathway have undergone extensive revisions, including serial design and labeling changes, since their initial approvals, often without supporting clinical data. Ophthalmologists should take into consideration that cumulative revisions may render the clinical evidence that supported an original FDA approval less relevant to newer device models. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Novak, A.; Simon, L.; Lotton, P.
2018-04-01
Mechanical transducers, such as shakers, loudspeakers and compression drivers that are used as excitation devices to excite acoustical or mechanical nonlinear systems under test are imperfect. Due to their nonlinear behaviour, unwanted contributions appear at their output besides the wanted part of the signal. Since these devices are used to study nonlinear systems, it should be required to measure properly the systems under test by overcoming the influence of the nonlinear excitation device. In this paper, a simple method that corrects distorted output signal of the excitation device by means of predistortion of its input signal is presented. A periodic signal is applied to the input of the excitation device and, from analysing the output signal of the device, the input signal is modified in such a way that the undesirable spectral components in the output of the excitation device are cancelled out after few iterations of real-time processing. The experimental results provided on an electrodynamic shaker show that the spectral purity of the generated acceleration output approaches 100 dB after few iterations (1 s). This output signal, applied to the system under test, is thus cleaned from the undesirable components produced by the excitation device; this is an important condition to ensure a correct measurement of the nonlinear system under test.
Lopes, A G; Keshavarz-Moore, E
2013-01-01
During centrifugation operation, the major challenge in the recovery of extracellular proteins is the removal of the maximum liquid entrapped within the spaces between the settled solids-dewatering level. The ability of the scroll decanter centrifuge (SDC) to process continuously large amounts of feed material with high concentration of solids without the need for resuspension of feeds, and also to achieve relatively high dewatering, could be of great benefit for future use in the biopharmaceutical industry. However, for reliable prediction of dewatering in such a centrifuge, tests using the same kind of equipment at pilot-scale are required, which are time consuming and costly. To alleviate the need of pilot-scale trials, a novel USD device, with reduced amounts of feed (2 mL) and to be used in the laboratory, was developed to predict the dewatering levels of a SDC. To verify USD device, dewatering levels achieved were plotted against equivalent compression (Gtcomp ) and decanting (Gtdec ) times, obtained from scroll rates and feed flow rates operated at pilot-scale, respectively. The USD device was able to successfully match dewatering trends of the pilot-scale as a function of both Gtcomp and Gtdec , particularly for high cell density feeds, hence accounting for all key variables that influenced dewatering in a SDC. In addition, it accurately mimicked the maximum dewatering performance of the pilot-scale equipment. Therefore the USD device has the potential to be a useful tool at early stages of process development to gather performance data in the laboratory thus minimizing lengthy and costly runs with pilot-scale SDC. © 2013 American Institute of Chemical Engineers.
A power-efficient communication system between brain-implantable devices and external computers.
Yao, Ning; Lee, Heung-No; Chang, Cheng-Chun; Sclabassi, Robert J; Sun, Mingui
2007-01-01
In this paper, we propose a power efficient communication system for linking a brain-implantable device to an external system. For battery powered implantable devices, the processor and the transmitter power should be reduced in order to both conserve battery power and reduce the health risks associated with transmission. To accomplish this, a joint source-channel coding/decoding system is devised. Low-density generator matrix (LDGM) codes are used in our system due to their low encoding complexity. The power cost for signal processing within the implantable device is greatly reduced by avoiding explicit source encoding. Raw data which is highly correlated is transmitted. At the receiver, a Markov chain source correlation model is utilized to approximate and capture the correlation of raw data. A turbo iterative receiver algorithm is designed which connects the Markov chain source model to the LDGM decoder in a turbo-iterative way. Simulation results show that the proposed system can save up to 1 to 2.5 dB on transmission power.
Iterative approach as alternative to S-matrix in modal methods
NASA Astrophysics Data System (ADS)
Semenikhin, Igor; Zanuccoli, Mauro
2014-12-01
The continuously increasing complexity of opto-electronic devices and the rising demands of simulation accuracy lead to the need of solving very large systems of linear equations making iterative methods promising and attractive from the computational point of view with respect to direct methods. In particular, iterative approach potentially enables the reduction of required computational time to solve Maxwell's equations by Eigenmode Expansion algorithms. Regardless of the particular eigenmodes finding method used, the expansion coefficients are computed as a rule by scattering matrix (S-matrix) approach or similar techniques requiring order of M3 operations. In this work we consider alternatives to the S-matrix technique which are based on pure iterative or mixed direct-iterative approaches. The possibility to diminish the impact of M3 -order calculations to overall time and in some cases even to reduce the number of arithmetic operations to M2 by applying iterative techniques are discussed. Numerical results are illustrated to discuss validity and potentiality of the proposed approaches.
Thomson scattering for core plasma on DEMO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhin, E. E.; Kurskiev, G. S.; Tolstyakov, S. Yu.
2014-08-21
This paper describes the challenges of Thomson scattering implementation for core plasma on DEMO and evaluates the capability to measure extremely high electron temperature range 0.5-40keV. A number of solutions to be developed for ITER diagnostics are suggested in consideration of their realization for DEMO. New approaches suggested for DEMO may also be of interest to ITER and currently operating magnetic confinement devices.
ERIC Educational Resources Information Center
Byrne, Jenny; Speller, Viv; Dewhirst, Sue; Roderick, Paul; Almond, Palo; Grace, Marcus; Memon, Anjum
2012-01-01
Purpose: The purpose of this paper is to discuss a curriculum change in the provision of health promotion in pre-service teacher education in a one-year postgraduate certificate in education (PGCE) secondary course in one Higher Education Institution (HEI) in England. Design/methodology/approach: The paper describes the iterative development…
Expanding the Role of School Psychologists to Support Early Career Teachers: A Mixed-Method Study
ERIC Educational Resources Information Center
Shernoff, Elisa S.; Frazier, Stacy L.; Maríñez-Lora, Ané M.; Lakind, Davielle; Atkins, Marc S.; Jakobsons, Lara; Hamre, Bridget K.; Bhaumik, Dulal K.; Parker-Katz, Michelle; Neal, Jennifer Watling; Smylie, Mark A.; Patel, Darshan A.
2016-01-01
School psychologists have training and expertise in consultation and evidence-based interventions that position them well to support early career teachers (ECTs). The current study involved iterative development and pilot testing of an intervention to help ECTs become more effective in classroom management and engaging learners, as well as more…
Forriez, O; Masseline, J; Coadic, D; David, V; Trouiller, P; Sztrymf, B
2017-02-02
To test the effect of a new coverlet device, allowing air circulation at the body/underlying surface interface, on skin microclimate management. This prospective observational pilot study took place in a 15-bed university-affiliated intensive care unit. Overall, 34 mechanically ventilated patients were included. Skin humidity and temperature were monitored before and after the implementation of the tested device at the occiput, scapulas, buttocks and sacrum. Humidity and temperature were evaluated through surface skin impedance and an infra-red thermometer, respectively. Health professionals were asked to evaluate the device. After implementation of the coverlet device, there was a rapid, sustained and significant decrease in skin humidity at all sites ranging from 6 % to 15 %, excluding the occiput. Skin temperature also significantly decreased from 1 % at both scapulas, but not at the other studied body sites. No side effects were observed. Health professionals reported that the device was easy and quick to install. Although they did not report a subjective improvement in skin moisture or temperature, they considered the device to be efficient. Although limited by its design, this pilot study suggests a good efficacy of the studied device on skin microclimate management. Further data are warranted to test the clinical implications of our findings.
An Evaluation of the Effectiveness of a Self-Tutoring Approach Applied to Pilot Training.
ERIC Educational Resources Information Center
Hatch, Richard S.
One of the critical aspects of the pilot's job is the requirement for accurate and ready recall of a large body of flight information. The effectiveness of a voluntary self-tutoring device to facilitate information acquisition and retention was examined. The device was a card machine which presented and scored responses to multiple choice…
Using Smart Phones in Language Learning--A Pilot Study to Turn CALL into MALL
ERIC Educational Resources Information Center
Kétyi, András
2013-01-01
The popularity of smart phones has increased enormously in the last few years. Because of the increasing penetration of these devices and the above-average willingness of our students using new tools and devices in language courses, we decided to design a voluntary pilot project for mobile language learning for students who learn German as a…
Operation and maintenance requirements of the Army Remotely Piloted Vehicle (RPV)
NASA Technical Reports Server (NTRS)
1983-01-01
The Remotely Piloted Vehicle (RPV) system is being developed to provide the Army with a target acquistion, target location, and laser designation capability that will significantly enhance the effectiveness of the artillery. Iterative analyses of the manpower, personnel, and training (MPT) requirements for an RPV system configured to accommodate both a daylight television and a forward looking infrared (FLIR) mission payload subsystem (FMPS) and related support subsystems are examined. Additionally, this analysis incorporates a 24 hour-a-day operational scenario. Therefore, the information presented was developed with a view towards delineating the differences (or deltas) imposed by the new requirements resulting from FMPS/24 hour operating day functions.
DOT National Transportation Integrated Search
2001-05-01
Avionics devices designed to provide pilots with graphically displayed traffic information will enable pilots to acquire and verify the identity of any intruder aircraft within the general area, either before or in accordance with a controller-issued...
Pilots' visual scan patterns and situation awareness in flight operations.
Yu, Chung-San; Wang, Eric Min-Yang; Li, Wen-Chin; Braithwaite, Graham
2014-07-01
Situation awareness (SA) is considered an essential prerequisite for safe flying. If the impact of visual scanning patterns on a pilot's situation awareness could be identified in flight operations, then eye-tracking tools could be integrated with flight simulators to improve training efficiency. Participating in this research were 18 qualified, mission-ready fighter pilots. The equipment included high-fidelity and fixed-base type flight simulators and mobile head-mounted eye-tracking devices to record a subject's eye movements and SA while performing air-to-surface tasks. There were significant differences in pilots' percentage of fixation in three operating phases: preparation (M = 46.09, SD = 14.79), aiming (M = 24.24, SD = 11.03), and release and break-away (M = 33.98, SD = 14.46). Also, there were significant differences in pilots' pupil sizes, which were largest in the aiming phase (M = 27,621, SD = 6390.8), followed by release and break-away (M = 27,173, SD = 5830.46), then preparation (M = 25,710, SD = 6078.79), which was the smallest. Furthermore, pilots with better SA performance showed lower perceived workload (M = 30.60, SD = 17.86), and pilots with poor SA performance showed higher perceived workload (M = 60.77, SD = 12.72). Pilots' percentage of fixation and average fixation duration among five different areas of interest showed significant differences as well. Eye-tracking devices can aid in capturing pilots' visual scan patterns and SA performance, unlike traditional flight simulators. Therefore, integrating eye-tracking devices into the simulator may be a useful method for promoting SA training in flight operations, and can provide in-depth understanding of the mechanism of visual scan patterns and information processing to improve training effectiveness in aviation.
Adaptive Neuro-Fuzzy Modeling of UH-60A Pilot Vibration
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Malki, Heidar A.; Langari, Reza
2003-01-01
Adaptive neuro-fuzzy relationships have been developed to model the UH-60A Black Hawk pilot floor vertical vibration. A 200 point database that approximates the entire UH-60A helicopter flight envelope is used for training and testing purposes. The NASA/Army Airloads Program flight test database was the source of the 200 point database. The present study is conducted in two parts. The first part involves level flight conditions and the second part involves the entire (200 point) database including maneuver conditions. The results show that a neuro-fuzzy model can successfully predict the pilot vibration. Also, it is found that the training phase of this neuro-fuzzy model takes only two or three iterations to converge for most cases. Thus, the proposed approach produces a potentially viable model for real-time implementation.
Pilot training: What can surgeons learn from it?
Sommer, Kai-Jörg
2014-03-01
To provide healthcare professionals with an insight into training in aviation and its possible transfer into surgery. From research online and into company archives, relevant publications and information were identified. Current airline pilot training consists of two categories, basic training and type-rating. Training methods comprise classroom instruction, computer-based training and practical training, in either the aircraft or a flight-training device, which ranges from a fixed-base flight-training device to a full flight simulator. Pilot training not only includes technical and procedural instruction, but also training in non-technical skills like crisis management, decision-making, leadership and communication. Training syllabuses, training devices and instructors are internationally standardized and these standards are legally binding. Re-qualification and recurrent training are mandatory at all stages of a pilot's and instructor's career. Surgeons and pilots have much in common, i.e., they work in a 'real-time' three-dimensional environment under high physiological and psychological stress, operating expensive equipment, and the ultimate cost for error is measured in human lives. However, their training differs considerably. Transferring these well-tried aviation methods into healthcare will make surgical training more efficient, more effective and ultimately safer.
A pilot study of implantable cardiac device interrogation by emergency department personnel.
Neuenschwander, James F; Hiestand, Brian C; Peacock, W Frank; Billings, John M; Sondrup, Cole; Hummel, John D; Abraham, William T
2014-03-01
Implanted devices (eg, pacemakers and defibrillators) provide valuable information and may be interrogated to obtain diagnostic information and to direct management. During admission to an emergency department (ED), significant time and cost are spent waiting for device manufacturer representatives or cardiologists to access the data. If ED personnel could safely interrogate implanted devices, more rapid disposition could occur, thus leading to potentially better outcomes at a reduced cost. This was a pilot study examining the feasibility of ED device interrogation. This was a prospective convenience sample study of patients presenting to the ED with any chief complaint and who had an implantable device capable of being interrogated by a Medtronic reader. After obtaining informed consent, study patients underwent device interrogation by ED research personnel. After reviewing the device data, the physician documented their opinions of the value of data in aiding care. Patients were followed up at intervals ranging from 30 days out to 1 year to determine adverse events relating to interrogation. Forty-four patients underwent device interrogation. Their mean age was 56 ± 14.7 years (range, 28-83), 75% (33/44) were male and 75% (33/44) were hospitalized from the ED. The interrogations took less than 10 minutes 89% of the time. In 60% of the cases, ED physicians reported the data-assisted patient care. No adverse events were reported relating to the ED interrogations. In this pilot study, we found that ED personnel can safely and quickly interrogate implantable devices to obtain potentially useful clinical data.
Pilot Perception of Electronic Flight Bags at Part 121 Air Carriers
NASA Astrophysics Data System (ADS)
Lytle, Donley
Electronic Flight Bags (EFBs) have been approved for use by pilots in flight operations at many Part 121 air carriers in the United States since 2010. As an automated device replacing paper in the cockpit, there are many human factor issues that relate to operation of the EFB. EFBs have been cited in accidents and incidents worldwide in large, transport category aircraft. While the EFB was not cited as the main cause of the accident/incident, it has been listed as a contributing factor. This study looks at pilot perception related to the safety aspect of the EFB in flight operations at Part 121 carriers in the United States. It surveys pilots that utilize the device in daily, routine flight operations to determine their perception of the EFB. The study is followed with a survey of a small group of pilots to help explain the results and any correlation between the variables.
14 CFR 61.13 - Issuance of airman certificates, ratings, and authorizations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... pilot authorization, a flight simulator or flight training device may be used if it is approved by the..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRMEN CERTIFICATION: PILOTS, FLIGHT INSTRUCTORS, AND GROUND... the Administrator, a person whose pilot, flight instructor, or ground instructor certificate has been...
Simulation of RF-fields in a fusion device
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Witte, Dieter; Bogaert, Ignace; De Zutter, Daniel
2009-11-26
In this paper the problem of scattering off a fusion plasma is approached from the point of view of integral equations. Using the volume equivalence principle an integral equation is derived which describes the electromagnetic fields in a plasma. The equation is discretized with MoM using conforming basis functions. This reduces the problem to solving a dense matrix equation. This can be done iteratively. Each iteration can be sped up using FFTs.
Physics of Tokamak Plasma Start-up
NASA Astrophysics Data System (ADS)
Mueller, Dennis
2012-10-01
This tutorial describes and reviews the state-of-art in tokamak plasma start-up and its importance to next step devices such as ITER, a Fusion Nuclear Science Facility and a Tokamak/ST demo. Tokamak plasma start-up includes breakdown of the initial gas, ramp-up of the plasma current to its final value and the control of plasma parameters during those phases. Tokamaks rely on an inductive component, typically a central solenoid, which has enabled attainment of high performance levels that has enabled the construction of the ITER device. Optimizing the inductive start-up phase continues to be an area of active research, especially in regards to achieving ITER scenarios. A new generation of superconducting tokamaks, EAST and KSTAR, experiments on DIII-D and operation with JET's ITER-like wall are contributing towards this effort. Inductive start-up relies on transformer action to generate a toroidal loop voltage and successful start-up is determined by gas breakdown, avalanche physics and plasma-wall interaction. The goal of achieving steady-sate tokamak operation has motivated interest in other methods for start-up that do not rely on the central solenoid. These include Coaxial Helicity Injection, outer poloidal field coil start-up, and point source helicity injection, which have achieved 200, 150 and 100 kA respectively of toroidal current on closed flux surfaces. Other methods including merging reconnection startup and Electron Bernstein Wave (EBW) plasma start-up are being studied on various devices. EBW start-up generates a directed electron channel due to wave particle interaction physics while the other methods mentioned rely on magnetic helicity injection and magnetic reconnection which are being modeled and understood using NIMROD code simulations.
EDITORIAL: ECRH physics and technology in ITER
NASA Astrophysics Data System (ADS)
Luce, T. C.
2008-05-01
It is a great pleasure to introduce you to this special issue containing papers from the 4th IAEA Technical Meeting on ECRH Physics and Technology in ITER, which was held 6-8 June 2007 at the IAEA Headquarters in Vienna, Austria. The meeting was attended by more than 40 ECRH experts representing 13 countries and the IAEA. Presentations given at the meeting were placed into five separate categories EC wave physics: current understanding and extrapolation to ITER Application of EC waves to confinement and stability studies, including active control techniques for ITER Transmission systems/launchers: state of the art and ITER relevant techniques Gyrotron development towards ITER needs System integration and optimisation for ITER. It is notable that the participants took seriously the focal point of ITER, rather than simply contributing presentations on general EC physics and technology. The application of EC waves to ITER presents new challenges not faced in the current generation of experiments from both the physics and technology viewpoints. High electron temperatures and the nuclear environment have a significant impact on the application of EC waves. The needs of ITER have also strongly motivated source and launcher development. Finally, the demonstrated ability for precision control of instabilities or non-inductive current drive in addition to bulk heating to fusion burn has secured a key role for EC wave systems in ITER. All of the participants were encouraged to submit their contributions to this special issue, subject to the normal publication and technical merit standards of Nuclear Fusion. Almost half of the participants chose to do so; many of the others had been published in other publications and therefore could not be included in this special issue. The papers included here are a representative sample of the meeting. The International Advisory Committee also asked the three summary speakers from the meeting to supply brief written summaries (O. Sauter: EC wave physics and applications, M. Thumm: Source and transmission line development, and S. Cirant: ITER specific system designs). These summaries are included in this issue to give a more complete view of the technical meeting. Finally, it is appropriate to mention the future of this meeting series. With the ratification of the ITER agreement and the formation of the ITER International Organization, it was recognized that meetings conducted by outside agencies with an exclusive focus on ITER would be somewhat unusual. However, the participants at this meeting felt that the gathering of international experts with diverse specialities within EC wave physics and technology to focus on using EC waves in future fusion devices like ITER was extremely valuable. It was therefore recommended that this series of meetings continue, but with the broader focus on the application of EC waves to steady-state and burning plasma experiments including demonstration power plants. As the papers in this special issue show, the EC community is already taking seriously the challenges of applying EC waves to fusion devices with high neutron fluence and continuous operation at high reliability.
NASA Astrophysics Data System (ADS)
Evans, T. E.
2013-07-01
Large edge-localized mode (ELM) control techniques must be developed to help ensure the success of burning and ignited fusion plasma devices such as tokamaks and stellarators. In full performance ITER tokamak discharges, with QDT = 10, the energy released by a single ELM could reach ˜30 MJ which is expected to result in an energy density of 10-15 MJ/m2on the divertor targets. This will exceed the estimated divertor ablation limit by a factor of 20-30. A worldwide research program is underway to develop various types of ELM control techniques in preparation for ITER H-mode plasma operations. An overview of the ELM control techniques currently being developed is discussed along with the requirements for applying these techniques to plasmas in ITER. Particular emphasis is given to the primary approaches, pellet pacing and resonant magnetic perturbation fields, currently being considered for ITER.
Design of Multimedia Situational Awareness Training for Pilots.
ERIC Educational Resources Information Center
Homan, Willem J.
1998-01-01
A recent development in aviation is the personal computer aviation training device (PC-ATD). This article provides an overview of instructional multimedia for pilot training, specifically for enhancing situational awareness (SA), a state in which a pilot's perceptions match reality. Discusses how PC-based trainers can be used to familiarize pilots…
Active spectroscopic measurements using the ITER diagnostic system.
Thomas, D M; Counsell, G; Johnson, D; Vasu, P; Zvonkov, A
2010-10-01
Active (beam-based) spectroscopic measurements are intended to provide a number of crucial parameters for the ITER device being built in Cadarache, France. These measurements include the determination of impurity ion temperatures, absolute densities, and velocity profiles, as well as the determination of the plasma current density profile. Because ITER will be the first experiment to study long timescale (∼1 h) fusion burn plasmas, of particular interest is the ability to study the profile of the thermalized helium ash resulting from the slowing down and confinement of the fusion alphas. These measurements will utilize both the 1 MeV heating neutral beams and a dedicated 100 keV hydrogen diagnostic neutral beam. A number of separate instruments are being designed and built by several of the ITER partners to meet the different spectroscopic measurement needs and to provide the maximum physics information. In this paper, we describe the planned measurements, the intended diagnostic ensemble, and we will discuss specific physics and engineering challenges for these measurements in ITER.
2013-01-01
Background Robotic arm therapy devices that incorporate actuated assistance can enhance arm recovery, motivate patients to practice, and allow therapists to deliver semi-autonomous training. However, because such devices are often complex and actively apply forces, they have not achieved widespread use in rehabilitation clinics or at home. This paper describes the design and pilot testing of a simple, mechanically passive device that provides robot-like assistance for active arm training using the principle of mechanical resonance. Methods The Resonating Arm Exerciser (RAE) consists of a lever that attaches to the push rim of a wheelchair, a forearm support, and an elastic band that stores energy. Patients push and pull on the lever to roll the wheelchair back and forth by about 20 cm around a neutral position. We performed two separate pilot studies of the device. In the first, we tested whether the predicted resonant properties of RAE amplified a user’s arm mobility by comparing his or her active range of motion (AROM) in the device achieved during a single, sustained push and pull to the AROM achieved during rocking. In a second pilot study designed to test the therapeutic potential of the device, eight participants with chronic stroke (35 ± 24 months since injury) and a mean, stable, initial upper extremity Fugl-Meyer (FM) score of 17 ± 8 / 66 exercised with RAE for eight 45 minute sessions over three weeks. The primary outcome measure was the average AROM measured with a tilt sensor during a one minute test, and the secondary outcome measures were the FM score and the visual analog scale for arm pain. Results In the first pilot study, we found people with a severe motor impairment after stroke intuitively found the resonant frequency of the chair, and the mechanical resonance of RAE amplified their arm AROM by a factor of about 2. In the second pilot study, AROM increased by 66% ± 20% (p = 0.003). The mean FM score increase was 8.5 ± 4 pts (p = 0.009). Subjects did not report discomfort or an increase in arm pain with rocking. Improvements were sustained at three months. Conclusions These results demonstrate that a simple mechanical device that snaps onto a manual wheelchair can use resonance to assist arm training, and that such training shows potential for safely increasing arm movement ability for people with severe chronic hemiparetic stroke. PMID:23597303
Zondervan, Daniel K; Palafox, Lorena; Hernandez, Jorge; Reinkensmeyer, David J
2013-04-18
Robotic arm therapy devices that incorporate actuated assistance can enhance arm recovery, motivate patients to practice, and allow therapists to deliver semi-autonomous training. However, because such devices are often complex and actively apply forces, they have not achieved widespread use in rehabilitation clinics or at home. This paper describes the design and pilot testing of a simple, mechanically passive device that provides robot-like assistance for active arm training using the principle of mechanical resonance. The Resonating Arm Exerciser (RAE) consists of a lever that attaches to the push rim of a wheelchair, a forearm support, and an elastic band that stores energy. Patients push and pull on the lever to roll the wheelchair back and forth by about 20 cm around a neutral position. We performed two separate pilot studies of the device. In the first, we tested whether the predicted resonant properties of RAE amplified a user's arm mobility by comparing his or her active range of motion (AROM) in the device achieved during a single, sustained push and pull to the AROM achieved during rocking. In a second pilot study designed to test the therapeutic potential of the device, eight participants with chronic stroke (35 ± 24 months since injury) and a mean, stable, initial upper extremity Fugl-Meyer (FM) score of 17 ± 8 / 66 exercised with RAE for eight 45 minute sessions over three weeks. The primary outcome measure was the average AROM measured with a tilt sensor during a one minute test, and the secondary outcome measures were the FM score and the visual analog scale for arm pain. In the first pilot study, we found people with a severe motor impairment after stroke intuitively found the resonant frequency of the chair, and the mechanical resonance of RAE amplified their arm AROM by a factor of about 2. In the second pilot study, AROM increased by 66% ± 20% (p = 0.003). The mean FM score increase was 8.5 ± 4 pts (p = 0.009). Subjects did not report discomfort or an increase in arm pain with rocking. Improvements were sustained at three months. These results demonstrate that a simple mechanical device that snaps onto a manual wheelchair can use resonance to assist arm training, and that such training shows potential for safely increasing arm movement ability for people with severe chronic hemiparetic stroke.
ERIC Educational Resources Information Center
Browning, Robert F.; And Others
This report details the setting up of a program to assess the training potential of a new simulator (Device 2F64C) for training SH-3 replacement helicopter pilots. Section 2 describes the training situation at the fleet readiness squadron prior to and during the transition to a new curriculum that resulted from an instructional system development…
A Description of the "Crow's Foot" Tunnel Concept
NASA Technical Reports Server (NTRS)
Parrish, Russell V.; Williams, Steven P.; Arthur, Jarvis J., III; Kramer, Lynda J.; Bailey, Randall E.; Prinzel, Lawrence J., III; Norman, R. Michael
2006-01-01
NASA Langley Research Center has actively pursued the development and the use of pictorial or three-dimensional perspective displays of tunnel-, pathway- or highway-in-the-sky concepts for presenting flight path information to pilots in all aircraft categories (e.g., transports, General Aviation, rotorcraft) since the late 1970s. Prominent among these efforts has been the development of the crow s foot tunnel concept. The crow's foot tunnel concept emerged as the consensus pathway concept from a series of interactive workshops that brought together government and industry display designers, test pilots, and airline pilots to iteratively design, debate, and fly various pathway concepts. Over years of use in many simulation and flight test activities at NASA and elsewhere, modifications have refined and adapted the tunnel concept for different applications and aircraft categories (i.e., conventional transports, High Speed Civil Transport, General Aviation). A description of those refinements follows the definition of the original tunnel concept.
Pilot interaction with automated airborne decision making systems
NASA Technical Reports Server (NTRS)
Hammer, John M.; Wan, C. Yoon; Vasandani, Vijay
1987-01-01
The current research is focused on detection of human error and protection from its consequences. A program for monitoring pilot error by comparing pilot actions to a script was described. It dealt primarily with routine errors (slips) that occurred during checklist activity. The model to which operator actions were compared was a script. Current research is an extension along these two dimensions. The ORS fault detection aid uses a sophisticated device model rather than a script. The newer initiative, the model-based and constraint-based warning system, uses an even more sophisticated device model and is to prevent all types of error, not just slips or bad decision.
The Iterative Design of a Mobile Learning Application to Support Scientific Inquiry
ERIC Educational Resources Information Center
Marty, Paul F.; Mendenhall, Anne; Douglas, Ian; Southerland, Sherry A.; Sampson, Victor; Kazmer, Michelle M.; Alemanne, Nicole; Clark, Amanda; Schellinger, Jennifer
2013-01-01
The ubiquity of mobile devices makes them well suited for field-based learning experiences that require students to gather data as part of the process of developing scientific inquiry practices. The usefulness of these devices, however, is strongly influenced by the nature of the applications students use to collect data in the field. To…
Inferring the Presence of Reverse Proxies Through Timing Analysis
2015-06-01
16 Figure 3.2 The three different instances of timing measurement configurations 17 Figure 3.3 Permutation of a web request iteration...Their data showed that they could detect at least 6 bits of entropy between unlike devices and that it was enough to determine that they are in fact...depending on the permutation being executed so that every iteration was conducted under the same distance 15 City Lat Long City Lat Long
NASA Astrophysics Data System (ADS)
Yang, C.; Zheng, W.; Zhang, M.; Yuan, T.; Zhuang, G.; Pan, Y.
2016-06-01
Measurement and control of the plasma in real-time are critical for advanced Tokamak operation. It requires high speed real-time data acquisition and processing. ITER has designed the Fast Plant System Controllers (FPSC) for these purposes. At J-TEXT Tokamak, a real-time data acquisition and processing framework has been designed and implemented using standard ITER FPSC technologies. The main hardware components of this framework are an Industrial Personal Computer (IPC) with a real-time system and FlexRIO devices based on FPGA. With FlexRIO devices, data can be processed by FPGA in real-time before they are passed to the CPU. The software elements are based on a real-time framework which runs under Red Hat Enterprise Linux MRG-R and uses Experimental Physics and Industrial Control System (EPICS) for monitoring and configuring. That makes the framework accord with ITER FPSC standard technology. With this framework, any kind of data acquisition and processing FlexRIO FPGA program can be configured with a FPSC. An application using the framework has been implemented for the polarimeter-interferometer diagnostic system on J-TEXT. The application is able to extract phase-shift information from the intermediate frequency signal produced by the polarimeter-interferometer diagnostic system and calculate plasma density profile in real-time. Different algorithms implementations on the FlexRIO FPGA are compared in the paper.
Magnetic Control of Locked Modes in Present Devices and ITER
NASA Astrophysics Data System (ADS)
Volpe, F. A.; Sabbagh, S.; Sweeney, R.; Hender, T.; Kirk, A.; La Haye, R. J.; Strait, E. J.; Ding, Y. H.; Rao, B.; Fietz, S.; Maraschek, M.; Frassinetti, L.; in, Y.; Jeon, Y.; Sakakihara, S.
2014-10-01
The toroidal phase of non-rotating (``locked'') neoclassical tearing modes was controlled in several devices by means of applied magnetic perturbations. Evidence is presented from various tokamaks (ASDEX Upgrade, DIII-D, JET, J-TEXT, KSTAR), spherical tori (MAST, NSTX) and a reversed field pinch (EXTRAP-T2R). Furthermore, the phase of interchange modes was controlled in the LHD helical device. These results share a common interpretation in terms of torques acting on the mode. Based on this interpretation, it is predicted that control-coil currents will be sufficient to control the phase of locking in ITER. This will be possible both with the internal coils and with the external error-field-correction coils, and might have promising consequences for disruption avoidance (by aiding the electron cyclotron current drive stabilization of locked modes), as well as for spatially distributing heat loads during disruptions. This work was supported in part by the US Department of Energy under DE-SC0008520, DE-FC-02-04ER54698 and DE-AC02-09CH11466.
Development of an electrostatic dust detector for tungsten dust
NASA Astrophysics Data System (ADS)
Starkey, D.; Hammond, K.; Roquemore, L.; Skinner, C. H.
2012-10-01
Next-step fusion reactors, such as ITER, are expected to have large quantities of dust that will present hazards that have yet to be encountered in current fusion devices. To manage the amount of dust within the reactors a real-time dust detector must be implemented to ensure that dust does not reach hazardous levels. An electrostatic device that accomplishes this has already been tested on NSTX and Tore Supra [1,2]. We will present modifications of this device to improve its ruggedness to withstand the conditions that will be present in ITER. The detector consists of two tungsten wires wrapped around a macor cylinder that are biased at 100-300 V. Incident dust causes a measurable transient short circuit. Initial results have demonstrated the detection of tungsten particles. We will also present a potential method of electrostatic cleaning of residual dust from the detector.[4pt] [1] C. H. Skinner et al., Rev. Sci. Instrum., 81, 10E102 (2010)[0pt] [2] H. Roche et al., Phys. Scr., T145, (2011).
Summary of ECE presentations at EC-18
Taylor, G.
2015-03-12
There were nine ECE and one EBE presentation at EC-18. Four of the presentations were on various aspects of ECE on ITER. The ITER ECE diagnostic has entered an important detailed preliminary design phase and faces several design challenges in the next 2-3 years. Most of the other ECE presentations at the workshop were focused on applications of ECE diagnostics to plasma measurements, rather than improvements in technology, although it was apparent that heterodyne receiver technology continues to improve. CECE, ECE imaging and EBE imaging are increasingly providing valuable insights into plasma behavior that is important to understand if futuremore » burning plasma devices, such as ITER, FNSF and DEMO, are to be successful.« less
A pilot study of delivering peer health messages in an HIV clinic via mobile media.
Winstead-Derlega, Christopher; Rafaly, Mary; Delgado, Sarah; Freeman, Jason; Cutitta, Katherine; Miles, Tony; Ingersoll, Karen; Dillingham, Rebecca
2012-01-01
This pilot study tested the feasibility and impact of using mobile media devices to present peer health messages to human immunodeficiency virus (HIV)-positive patients. A convenience sample of 30 adult patients from an outpatient HIV clinic serving a mostly rural catchment area in central Virginia volunteered for the study. Participants viewed short videos of people discussing HIV health topics on an Apple (Cupertino, CA) iPod® touch® mobile device. Pre- and post-intervention surveys assessed attitudes related to engagement in care and disease disclosure. Participants found delivery of health information by the mobile device acceptable in a clinic setting. They used the technology without difficulty. Participants reported satisfaction with and future interest in viewing such videos after using the mobile devices. The majority of participants used the device to access more videos than requested, and many reported the videos "hit home." There were no significant changes in participant perceptions about engagement in care or HIV disclosure after the intervention. This pilot study demonstrates the feasibility and acceptability of using mobile media technology to deliver peer health messages. Future research should explore how to best use mobile media to improve engagement in care and reduce perceptions of stigma.
Motion and positional error correction for cone beam 3D-reconstruction with mobile C-arms.
Bodensteiner, C; Darolti, C; Schumacher, H; Matthäus, L; Schweikard, A
2007-01-01
CT-images acquired by mobile C-arm devices can contain artefacts caused by positioning errors. We propose a data driven method based on iterative 3D-reconstruction and 2D/3D-registration to correct projection data inconsistencies. With a 2D/3D-registration algorithm, transformations are computed to align the acquired projection images to a previously reconstructed volume. In an iterative procedure, the reconstruction algorithm uses the results of the registration step. This algorithm also reduces small motion artefacts within 3D-reconstructions. Experiments with simulated projections from real patient data show the feasibility of the proposed method. In addition, experiments with real projection data acquired with an experimental robotised C-arm device have been performed with promising results.
Effective Training for Flight in Icing Conditions
NASA Technical Reports Server (NTRS)
Barnhart, Billy P.; Ratvasky, Thomas P.
2007-01-01
The development of a piloted flight simulator called the Ice Contamination Effects Flight Training Device (ICEFTD) was recently completed. This device demonstrates the ability to accurately represent an iced airplane s flight characteristics and is utilized to train pilots in recognizing and recovering from aircraft handling anomalies that result from airframe ice formations. The ICEFTD was demonstrated at three recent short courses hosted by the University of Tennessee Space Institute. It was also demonstrated to a group of pilots at the National Test Pilot School. In total, eighty-four pilots and flight test engineers from industry and the regulatory community spent approximately one hour each in the ICEFTD to get a "hands on" lesson of an iced airplane s reduced performance and handling qualities. Additionally, pilot cues of impending upsets and recovery techniques were demonstrated. The purpose of this training was to help pilots understand how ice contamination affects aircraft handling so they may apply that knowledge to the operations of other aircraft undergoing testing and development. Participant feedback on the ICEFTD was very positive. Pilots stated that the simulation was very valuable, applicable to their occupations, and provided a safe way to explore the flight envelope. Feedback collected at each demonstration was also helpful to define additional improvements to the ICEFTD; many of which were then implemented in subsequent demonstrations.
Apollo 12 Mission image - Close-up view of the Solar Wind Panel
1969-11-19
AS12-47-6898 (19 Nov. 1969) --- A close-up view of the Solar Wind Composition device. Astronaut Alan L. Bean, lunar module pilot, took this photograph, after having deployed the device. Astronauts Charles Conrad Jr., commander, and Bean descended in the Apollo 12 Lunar Module (LM) to explore the moon, while astronaut Richard F. Gordon Jr., command module pilot, remained in lunar orbit with the Command and Service Modules (CSM).
STS-41 Commander Richards uses DTO 1206 portable computer onboard OV-103
NASA Technical Reports Server (NTRS)
1990-01-01
STS-41 Commander Richard N. Richards, at pilots station, uses Detailed Test Objective (DTO) Space Station Cursor Control Device Evaluation MACINTOSH portable computer on the forward flight deck of Discovery, Orbiter Vehicle (OV) 103. Richards tests the roller ball cursor control device. Surrounding Richards are checklists, forward flight deck windows, his lightweight communications kit assembly headset, a beverage container (orange-mango drink), and the pilots seat back and headrest.
NASA Astrophysics Data System (ADS)
Zhou, Y.; Zhang, X.; Xiao, W.
2018-04-01
As the geomagnetic sensor is susceptible to interference, a pre-processing total least square iteration method is proposed for calibration compensation. Firstly, the error model of the geomagnetic sensor is analyzed and the correction model is proposed, then the characteristics of the model are analyzed and converted into nine parameters. The geomagnetic data is processed by Hilbert transform (HHT) to improve the signal-to-noise ratio, and the nine parameters are calculated by using the combination of Newton iteration method and the least squares estimation method. The sifter algorithm is used to filter the initial value of the iteration to ensure that the initial error is as small as possible. The experimental results show that this method does not need additional equipment and devices, can continuously update the calibration parameters, and better than the two-step estimation method, it can compensate geomagnetic sensor error well.
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
14 CFR 25.697 - Lift and drag devices, controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.697 Lift and drag devices, controls. (a) Each lift device control must be designed so that the pilots... drag device control must be designed and located to make inadvertent operation improbable. Lift and...
NASA Astrophysics Data System (ADS)
Hosenfeld, Fabian; Horst, Fabian; Iñíguez, Benjamín; Lime, François; Kloes, Alexander
2017-11-01
Source-to-drain (SD) tunneling decreases the device performance in MOSFETs falling below the 10 nm channel length. Modeling quantum mechanical effects including SD tunneling has gained more importance specially for compact model developers. The non-equilibrium Green's function (NEGF) has become a state-of-the-art method for nano-scaled device simulation in the past years. In the sense of a multi-scale simulation approach it is necessary to bridge the gap between compact models with their fast and efficient calculation of the device current, and numerical device models which consider quantum effects of nano-scaled devices. In this work, an NEGF based analytical model for nano-scaled double-gate (DG) MOSFETs is introduced. The model consists of a closed-form potential solution of a classical compact model and a 1D NEGF formalism for calculating the device current, taking into account quantum mechanical effects. The potential calculation omits the iterative coupling and allows the straightforward current calculation. The model is based on a ballistic NEGF approach whereby backscattering effects are considered as second order effect in a closed-form. The accuracy and scalability of the non-iterative DG MOSFET model is inspected in comparison with numerical NanoMOS TCAD data for various channel lengths. With the help of this model investigations on short-channel and temperature effects are performed.
Usability of digital media in patients with COPD: a pilot study.
Cheung, Amy; Janssen, Anton; Amft, Oliver; Wouters, Emiel F M; Spruit, Martijn A
2013-04-01
Digital media can be integrated in tele-monitoring solutions, serving as the main interface between the patient and the caregiver. Consequently, the selection of the most appropriate digital medium for the specified target group is critical to ensure compliance with the tele-monitoring system. This pilot study aims to gather insights from patients with chronic obstructive pulmonary disease (COPD) on the ease-of-use, efficacy, effectiveness, and satisfaction of different types of digital media. Five off-the-shelf digital media devices were tested on nine patients at CIRO+ in Horn, The Netherlands. Usability was evaluated by asking patients to use each device to answer questions related to their symptoms and health status. Subsequently, patients completed a paper-based device usability questionnaire, which assessed prior experience with digital media, device dimensions, device controllability, response speed, screen readability, ease-of-use, and overall satisfaction. After testing all the devices, patients ranked the devices according to their preference. We identified the netbook as the preferred type of device due to its good controllability, fast response time, and large screen size. The smartphone was the least favorite device as patients found the size of the screen to be too small, which made it difficult to interact with. The pilot study has provided important insights to guide the selection of the most appropriate type of digital medium for implementation in tele-monitoring solutions for patients with COPD. As the digital medium is an important interface to the patient in tele-monitoring solutions, it is essential that patients feel motivated to interact with the digital medium on a regular basis.
Fusion Power measurement at ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bertalot, L.; Barnsley, R.; Krasilnikov, V.
2015-07-01
Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also tomore » the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)« less
Impurity seeding for tokamak power exhaust: from present devices via ITER to DEMO
NASA Astrophysics Data System (ADS)
Kallenbach, A.; Bernert, M.; Dux, R.; Casali, L.; Eich, T.; Giannone, L.; Herrmann, A.; McDermott, R.; Mlynek, A.; Müller, H. W.; Reimold, F.; Schweinzer, J.; Sertoli, M.; Tardini, G.; Treutterer, W.; Viezzer, E.; Wenninger, R.; Wischmeier, M.; the ASDEX Upgrade Team
2013-12-01
A future fusion reactor is expected to have all-metal plasma facing materials (PFMs) to ensure low erosion rates, low tritium retention and stability against high neutron fluences. As a consequence, intrinsic radiation losses in the plasma edge and divertor are low in comparison to devices with carbon PFMs. To avoid localized overheating in the divertor, intrinsic low-Z and medium-Z impurities have to be inserted into the plasma to convert a major part of the power flux into radiation and to facilitate partial divertor detachment. For burning plasma conditions in ITER, which operates not far above the L-H threshold power, a high divertor radiation level will be mandatory to avoid thermal overload of divertor components. Moreover, in a prototype reactor, DEMO, a high main plasma radiation level will be required in addition for dissipation of the much higher alpha heating power. For divertor plasma conditions in present day tokamaks and in ITER, nitrogen appears most suitable regarding its radiative characteristics. If elevated main chamber radiation is desired as well, argon is the best candidate for the simultaneous enhancement of core and divertor radiation, provided sufficient divertor compression can be obtained. The parameter Psep/R, the power flux through the separatrix normalized by the major radius, is suggested as a suitable scaling (for a given electron density) for the extrapolation of present day divertor conditions to larger devices. The scaling for main chamber radiation from small to large devices has a higher, more favourable dependence of about Prad,main/R2. Krypton provides the smallest fuel dilution for DEMO conditions, but has a more centrally peaked radiation profile compared to argon. For investigation of the different effects of main chamber and divertor radiation and for optimization of their distribution, a double radiative feedback system has been implemented in ASDEX Upgrade (AUG). About half the ITER/DEMO values of Psep/R have been achieved so far, and close to DEMO values of Prad,main/R2, albeit at lower Psep/R. Further increase of this parameter may be achieved by increasing the neutral pressure or improving the divertor geometry.
Reed, Terrie L; Drozda, Joseph P; Baskin, Kevin M; Tcheng, James; Conway, Karen; Wilson, Natalia; Marinac-Dabic, Danica; Heise, Theodore; Krucoff, Mitchell W
2017-12-01
The Medical Device Epidemiology Network (MDEpiNet) is a public private partnership (PPP) that provides a platform for collaboration on medical device evaluation and depth of expertise for supporting pilots to capture, exchange and use device information for improving device safety and protecting public health. The MDEpiNet SMART Think Tank, held in February, 2013, sought to engage expert stakeholders who were committed to improving the capture of device data, including Unique Device Identification (UDI), in key electronic health information. Prior to the Think Tank there was limited collaboration among stakeholders beyond a few single health care organizations engaged in electronic capture and exchange of device data. The Think Tank resulted in what has become two sustainable multi-stakeholder device data capture initiatives, BUILD and VANGUARD. These initiatives continue to mature within the MDEpiNet PPP structure and are well aligned with the goals outlined in recent FDA-initiated National Medical Device Planning Board and Medical Device Registry Task Force white papers as well as the vision for the National Evaluation System for health Technology.%. Published by Elsevier Inc.
Fostering learners' interaction with content: A learner-centered mobile device interface
NASA Astrophysics Data System (ADS)
Abdous, M.
2015-12-01
With the ever-increasing omnipresence of mobile devices in student life, leveraging smart devices to foster students' interaction with course content is critical. Following a learner-centered design iterative approach, we designed a mobile interface that may enable learners to access and interact with online course content efficiently and intuitively. Our design process leveraged recent technologies, such as bootstrap, Google's Material Design, HTML5, and JavaScript to design an intuitive, efficient, and portable mobile interface with a variety of built-in features, including context sensitive bookmarking, searching, progress tracking, captioning, and transcript display. The mobile interface also offers students the ability to ask context-related questions and to complete self-checks as they watch audio/video presentations. Our design process involved ongoing iterative feedback from learners, allowing us to refine and tweak the interface to provide learners with a unified experience across platforms and devices. The innovative combination of technologies built around well-structured and well-designed content seems to provide an effective learning experience to mobile learners. Early feedback indicates a high level of satisfaction with the interface's efficiency, intuitiveness, and robustness from both students and faculty.
14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).
Code of Federal Regulations, 2013 CFR
2013-01-01
... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...
14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).
Code of Federal Regulations, 2014 CFR
2014-01-01
... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...
14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).
Code of Federal Regulations, 2012 CFR
2012-01-01
... simulator, or in a flight training device for a particular type aircraft. (2) A check pilot (simulator) is a person who is qualified to conduct flight checks, but only in a flight simulator, in a flight training... (simulator) must accomplish the following— (1) Fly at least two flight segments as a required crewmember for...
Evaluation of the Texas Technology Immersion Pilot: Outcomes for the Third Year (2006-07)
ERIC Educational Resources Information Center
Shapley, Kelly; Sheehan, Daniel; Maloney, Catherine; Caranikas-Walker, Fanny
2008-01-01
The Technology Immersion Pilot (TIP), created by the Texas Legislature in 2003, set forth a vision for technology immersion in public schools. Senate Bill 396 called for the Texas Education Agency (TEA) to establish a pilot project to "immerse" schools in technology by providing a wireless mobile computing device for each teacher and…
Single-Pilot Workload Management in Entry-Level Jets
2013-09-01
under Instrument Flight Rules ( IFR ) in a Cessna Citation Mustang ELJ level 5 flight training device at CAMI. Eight of the pilots were Mustang owner...Instrument Landing System IFR ............Instrument Flight Rules IMC ...........Instrument Meteorological Conditions ISA...pilots flew an experimental flight with two legs involving high workload management under Instrument Flight Rules ( IFR ) in a Cessna Citation Mustang
ERIC Educational Resources Information Center
Matheny, W. G.; And Others
The document presents a summary description of the Air Force Human Resource Laboratory's Flying Training Division (AFHRL/FT) research capabilities for undergraduate pilot training. One of the research devices investigated is the Advanced Simulator for Undergraduate Pilot Training (ASUPT). The equipment includes the ASUPT, the instrumented T-37…
Pilot production and testing of high efficiency wraparound contact solar cells
NASA Technical Reports Server (NTRS)
Gillanders, M.
1981-01-01
Modifications were made to the process sequence until a device capable of high performance and satisfactory processing yields could be fabricated on a production line. Pilot production resulted in a 2 x 4 cm screen printed dielectric wraparound contact solar cell with average 28 C, Air Mass Zero (AMO) conversion efficiencies of 14.2% and reasonable process yields. This high performance was obtained with two different back contact configurations, making the device acceptable for many applications.
High-performance superconductors for Fusion Nuclear Science Facility
Zhai, Yuhu; Kessel, Chuck; Barth, Christian; ...
2016-11-09
High-performance superconducting magnets play an important role in the design of the next step large-scale, high-field fusion reactors such as the fusion nuclear science facility (FNSF) and the spherical tokamak (ST) pilot plant beyond ITER. Here, Princeton Plasma Physics Laboratory is currently leading the design studies of the FNSF and the ST pilot plant study. ITER, which is under construction in the south of France, utilizes the state-of-the-art low temperature superconducting magnet technology based on the cable-in-conduit conductor design, where over a thousand multifilament Nb 3Sn superconducting strands are twisted together to form a high-current-carrying cable inserted into a steelmore » jacket for coil windings. We present design options of the high-performance superconductors in the winding pack for the FNSF toroidal field magnet system based on the toroidal field radial build from the system code. For the low temperature superconductor options, the advanced J cNb 3Sn RRP strands (J c > 1000 A/mm 2 at 16 T, 4 K) from Oxford Superconducting Technology are under consideration. For the high-temperature superconductor options, the rectangular-shaped high-current HTS cable made of stacked YBCO tapes will be considered to validate feasibility of TF coil winding pack design for the ST-FNSF magnets.« less
High-performance superconductors for Fusion Nuclear Science Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Yuhu; Kessel, Chuck; Barth, Christian
High-performance superconducting magnets play an important role in the design of the next step large-scale, high-field fusion reactors such as the fusion nuclear science facility (FNSF) and the spherical tokamak (ST) pilot plant beyond ITER. Here, Princeton Plasma Physics Laboratory is currently leading the design studies of the FNSF and the ST pilot plant study. ITER, which is under construction in the south of France, utilizes the state-of-the-art low temperature superconducting magnet technology based on the cable-in-conduit conductor design, where over a thousand multifilament Nb 3Sn superconducting strands are twisted together to form a high-current-carrying cable inserted into a steelmore » jacket for coil windings. We present design options of the high-performance superconductors in the winding pack for the FNSF toroidal field magnet system based on the toroidal field radial build from the system code. For the low temperature superconductor options, the advanced J cNb 3Sn RRP strands (J c > 1000 A/mm 2 at 16 T, 4 K) from Oxford Superconducting Technology are under consideration. For the high-temperature superconductor options, the rectangular-shaped high-current HTS cable made of stacked YBCO tapes will be considered to validate feasibility of TF coil winding pack design for the ST-FNSF magnets.« less
NASA Astrophysics Data System (ADS)
Bittner-Rohrhofer, K.; Humer, K.; Weber, H. W.
The windings of the superconducting magnet coils for the ITER-FEAT fusion device are affected by high mechanical stresses at cryogenic temperatures and by a radiation environment, which impose certain constraints especially on the insulating materials. A glass fiber reinforced plastic (GFRP) laminate, which consists of Kapton/R-glass-fiber reinforcement tapes, vacuum-impregnated in a DGEBA epoxy system, was used for the European toroidal field model coil turn insulation of ITER. In order to assess its mechanical properties under the actual operating conditions of ITER-FEAT, cryogenic (77 K) static tensile tests and tension-tension fatigue measurements were done before and after irradiation to a fast neutron fluence of 1×10 22 m -2 ( E>0.1 MeV), i.e. the ITER-FEAT design fluence level. We find that the mechanical strength and the fracture behavior of this GFRP are strongly influenced by the winding direction of the tape and by the radiation induced delamination process. In addition, the composite swells by 3%, forming bubbles inside the laminate, and loses weight (1.4%) at the design fluence.
Motion cue effects on human pilot dynamics in manual control
NASA Technical Reports Server (NTRS)
Washizu, K.; Tanaka, K.; Endo, S.; Itoko, T.
1977-01-01
Two experiments were conducted to study the motion cue effects on human pilots during tracking tasks. The moving-base simulator of National Aerospace Laboratory was employed as the motion cue device, and the attitude director indicator or the projected visual field was employed as the visual cue device. The chosen controlled elements were second-order unstable systems. It was confirmed that with the aid of motion cues the pilot workload was lessened and consequently the human controllability limits were enlarged. In order to clarify the mechanism of these effects, the describing functions of the human pilots were identified by making use of the spectral and the time domain analyses. The results of these analyses suggest that the sensory system of the motion cues can yield the differential informations of the signal effectively, which coincides with the existing knowledges in the physiological area.
Architecture for Control of the K9 Rover
NASA Technical Reports Server (NTRS)
Bresina, John L.; Bualat, maria; Fair, Michael; Wright, Anne; Washington, Richard
2006-01-01
Software featuring a multilevel architecture is used to control the hardware on the K9 Rover, which is a mobile robot used in research on robots for scientific exploration and autonomous operation in general. The software consists of five types of modules: Device Drivers - These modules, at the lowest level of the architecture, directly control motors, cameras, data buses, and other hardware devices. Resource Managers - Each of these modules controls several device drivers. Resource managers can be commanded by either a remote operator or the pilot or conditional-executive modules described below. Behaviors and Data Processors - These modules perform computations for such functions as planning paths, avoiding obstacles, visual tracking, and stereoscopy. These modules can be commanded only by the pilot. Pilot - The pilot receives a possibly complex command from the remote operator or the conditional executive, then decomposes the command into (1) more-specific commands to the resource managers and (2) requests for information from the behaviors and data processors. Conditional Executive - This highest-level module interprets a command plan sent by the remote operator, determines whether resources required for execution of the plan are available, monitors execution, and, if necessary, selects an alternate branch of the plan.
NASA Astrophysics Data System (ADS)
Sun, Aihui; Tian, Xiaolin; Kong, Yan; Jiang, Zhilong; Liu, Fei; Xue, Liang; Wang, Shouyu; Liu, Cheng
2018-01-01
As a lensfree imaging technique, ptychographic iterative engine (PIE) method can provide both quantitative sample amplitude and phase distributions avoiding aberration. However, it requires field of view (FoV) scanning often relying on mechanical translation, which not only slows down measuring speed, but also introduces mechanical errors decreasing both resolution and accuracy in retrieved information. In order to achieve high-accurate quantitative imaging with fast speed, digital micromirror device (DMD) is adopted in PIE for large FoV scanning controlled by on/off state coding by DMD. Measurements were implemented using biological samples as well as USAF resolution target, proving high resolution in quantitative imaging using the proposed system. Considering its fast and accurate imaging capability, it is believed the DMD based PIE technique provides a potential solution for medical observation and measurements.
Simplified Negative Pressure Wound Therapy Device for Application in Low-Resource Settings.
Zurovcik, Danielle R; Mody, Gita N; Riviello, Robert; Slocum, Alex
2015-10-01
Negative pressure wound therapy (NPWT) provides proven wound healing benefits and is often a desirable wound treatment methodology. Unfortunately, NPWT devices are not widely available in low-resource settings. To overcome the identified NPWT barriers, a simplified NPWT (sNPWT) system was designed and iteratively improved during field-based testing. The sNPWT technology, our device design iterations, and the design-based results of our field tests are described in this article. The sNPWT system includes a bellows hand pump, an occlusive drape, and a tube with tube connectors, connecting the drape to the pump. The most critical property of an sNPWT system is that it must be airtight. The details of the design iterations, which are needed to achieve an occlusive system, are explained. During the design process, the sNPWT system was tested during the earthquake relief in Haiti. This testing found that a liquid sealant was necessary to seal the drape to the periwound skin. A study conducted in Rwanda verified that a liquid latex sealant was safe to use, and that the tube connector must be connected to the drape with an airtight method during the manufacturing process. This work has shown that sNPWT is feasible in low-resource settings. Since the completion of the clinical testing, the design has been further evolved, and the developers are working with contract manufacturers to produce the final design and preparing for regulatory approval applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yueqiang; Sabbagh, S. A.; Chapman, I. T.
The high-frequency noise measured by magnetic sensors, at levels above the typical frequency of resistive wall modes, is analyzed across a range of present tokamak devices including DIII-D, JET, MAST, ASDEX Upgrade, JT-60U, and NSTX. A high-pass filter enables identification of the noise component with Gaussian-like statistics that shares certain common characteristics in all devices considered. A conservative prediction is made for ITER plasma operation of the high-frequency noise component of the sensor signals, to be used for resistive wall mode feedback stabilization, based on the multimachine database. The predicted root-mean-square n = 1 (n is the toroidal mode number)more » noise level is 10 4 to 10 5 G/s for the voltage signal, and 0.1 to 1 G for the perturbed magnetic field signal. The lower cutoff frequency of the Gaussian pickup noise scales linearly with the sampling frequency, with a scaling coefficient of about 0.1. As a result, these basic noise characteristics should be useful for the modeling-based design of the feedback control system for the resistive wall mode in ITER.« less
Liu, Yueqiang; Sabbagh, S. A.; Chapman, I. T.; ...
2017-03-27
The high-frequency noise measured by magnetic sensors, at levels above the typical frequency of resistive wall modes, is analyzed across a range of present tokamak devices including DIII-D, JET, MAST, ASDEX Upgrade, JT-60U, and NSTX. A high-pass filter enables identification of the noise component with Gaussian-like statistics that shares certain common characteristics in all devices considered. A conservative prediction is made for ITER plasma operation of the high-frequency noise component of the sensor signals, to be used for resistive wall mode feedback stabilization, based on the multimachine database. The predicted root-mean-square n = 1 (n is the toroidal mode number)more » noise level is 10 4 to 10 5 G/s for the voltage signal, and 0.1 to 1 G for the perturbed magnetic field signal. The lower cutoff frequency of the Gaussian pickup noise scales linearly with the sampling frequency, with a scaling coefficient of about 0.1. As a result, these basic noise characteristics should be useful for the modeling-based design of the feedback control system for the resistive wall mode in ITER.« less
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
14 CFR 91.21 - Portable electronic devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
... use device to be a medical device intended for users in a non-clinical environment that is managed... promoting the safe use of medical devices presented a significant health challenge for which the HHCC could... pilot program, we are requesting manufacturers and distributors of medical devices cleared for home use...
ERIC Educational Resources Information Center
Shapley, Kelly; Maloney, Catherine; Caranikas-Walker, Fanny; Sheehan, Daniel
2008-01-01
The Technology Immersion Pilot (TIP), created by the Texas Legislature in 2003, called for the Texas Education Agency (TEA) to establish a pilot project to "immerse" schools in technology by providing a wireless mobile computing device for each teacher and student, technology-based learning resources, training for teachers to integrate…
14 CFR 61.51 - Pilot logbooks.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the aircraft departed and arrived, or for lessons in a flight simulator or flight training device, the location where the lesson occurred. (iv) Type and identification of aircraft, flight simulator, flight.... (v) Training received in a flight simulator, flight training device, or aviation training device from...
14 CFR 61.51 - Pilot logbooks.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the aircraft departed and arrived, or for lessons in a flight simulator or flight training device, the location where the lesson occurred. (iv) Type and identification of aircraft, flight simulator, flight.... (v) Training received in a flight simulator, flight training device, or aviation training device from...
14 CFR 61.51 - Pilot logbooks.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the aircraft departed and arrived, or for lessons in a flight simulator or flight training device, the location where the lesson occurred. (iv) Type and identification of aircraft, flight simulator, flight.... (v) Training received in a flight simulator, flight training device, or aviation training device from...
Efficient numerical method for analyzing optical bistability in photonic crystal microcavities.
Yuan, Lijun; Lu, Ya Yan
2013-05-20
Nonlinear optical effects can be enhanced by photonic crystal microcavities and be used to develop practical ultra-compact optical devices with low power requirements. The finite-difference time-domain method is the standard numerical method for simulating nonlinear optical devices, but it has limitations in terms of accuracy and efficiency. In this paper, a rigorous and efficient frequency-domain numerical method is developed for analyzing nonlinear optical devices where the nonlinear effect is concentrated in the microcavities. The method replaces the linear problem outside the microcavities by a rigorous and numerically computed boundary condition, then solves the nonlinear problem iteratively in a small region around the microcavities. Convergence of the iterative method is much easier to achieve since the size of the problem is significantly reduced. The method is presented for a specific two-dimensional photonic crystal waveguide-cavity system with a Kerr nonlinearity, using numerical methods that can take advantage of the geometric features of the structure. The method is able to calculate multiple solutions exhibiting the optical bistability phenomenon in the strongly nonlinear regime.
Development progresses of radio frequency ion source for neutral beam injector in fusion devices.
Chang, D H; Jeong, S H; Kim, T S; Park, M; Lee, K W; In, S R
2014-02-01
A large-area RF (radio frequency)-driven ion source is being developed in Germany for the heating and current drive of an ITER device. Negative hydrogen ion sources are the major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen (deuterium) ions have been successfully developed for the neutral beam heating systems at IPP (Max-Planck-Institute for Plasma Physics) in Germany. The first long-pulse ion source has been developed successfully with a magnetic bucket plasma generator including a filament heating structure for the first NBI system of the KSTAR tokamak. There is a development plan for an RF ion source at KAERI to extract the positive ions, which can be applied for the KSTAR NBI system and to extract the negative ions for future fusion devices such as the Fusion Neutron Source and Korea-DEMO. The characteristics of RF-driven plasmas and the uniformity of the plasma parameters in the test-RF ion source were investigated initially using an electrostatic probe.
Application of Titration-Based Screening for the Rapid Pilot Testing of High-Throughput Assays.
Zhang, Ji-Hu; Kang, Zhao B; Ardayfio, Ophelia; Ho, Pei-i; Smith, Thomas; Wallace, Iain; Bowes, Scott; Hill, W Adam; Auld, Douglas S
2014-06-01
Pilot testing of an assay intended for high-throughput screening (HTS) with small compound sets is a necessary but often time-consuming step in the validation of an assay protocol. When the initial testing concentration is less than optimal, this can involve iterative testing at different concentrations to further evaluate the pilot outcome, which can be even more time-consuming. Quantitative HTS (qHTS) enables flexible and rapid collection of assay performance statistics, hits at different concentrations, and concentration-response curves in a single experiment. Here we describe the qHTS process for pilot testing in which eight-point concentration-response curves are produced using an interplate asymmetric dilution protocol in which the first four concentrations are used to represent the range of typical HTS screening concentrations and the last four concentrations are added for robust curve fitting to determine potency/efficacy values. We also describe how these data can be analyzed to predict the frequency of false-positives, false-negatives, hit rates, and confirmation rates for the HTS process as a function of screening concentration. By taking into account the compound pharmacology, this pilot-testing paradigm enables rapid assessment of the assay performance and choosing the optimal concentration for the large-scale HTS in one experiment. © 2013 Society for Laboratory Automation and Screening.
Current training: Where are we?
NASA Technical Reports Server (NTRS)
Golden, Gerald
1992-01-01
Petroleum Helicopters, Inc. maintains a staff of 750 helicopter pilots. The initial, transition, upgrade, and recurrent training for these pilots requires a significant financial outlay. Since a major portion of that training is done to satisfy the requirements of FAR 61.57, 'Recent Flight Experience, Pilot in Command' and 135.297, 'Pilot in Command: Instrument Proficiency Check Requirements', much could be accomplished using an approved simulator. However, it is imperative that credit be given for training time spent in the simulators and that the device be realistic, practical, and affordable.
The effect of simulator motion on pilot training and evaluation
DOT National Transportation Integrated Search
2000-08-14
This study empirically examined the effect of simulator platform motion on airline pilot recurrent training and evaluation. It is driven by the need for sound scientific data on the relationship between certain key modern device features and their ef...
Code of Federal Regulations, 2012 CFR
2012-01-01
... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... observation check may be accomplished in part or in full in an aircraft, in a flight simulator, or in a flight... accomplished in full or in part in flight, in a flight simulator, or in a flight training device, as appropriate. (g) The initial and transition flight training for a check pilot (simulator) must include the...
This paper presents performance verification data on two types of high-rate separation devices utilized for solids removal: Vortex separation devices (a class of physical treatment technologies that use cylindrical chambers to create centrifugal forces that separate settleable so...
Conceptual design of the ITER fast-ion loss detector.
Garcia-Munoz, M; Kocan, M; Ayllon-Guerola, J; Bertalot, L; Bonnet, Y; Casal, N; Galdon, J; Garcia Lopez, J; Giacomin, T; Gonzalez-Martin, J; Gunn, J P; Jimenez-Ramos, M C; Kiptily, V; Pinches, S D; Rodriguez-Ramos, M; Reichle, R; Rivero-Rodriguez, J F; Sanchis-Sanchez, L; Snicker, A; Vayakis, G; Veshchev, E; Vorpahl, Ch; Walsh, M; Walton, R
2016-11-01
A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.
NASA Technical Reports Server (NTRS)
Jandhyala, Vikram (Inventor); Chowdhury, Indranil (Inventor)
2011-01-01
An approach that efficiently solves for a desired parameter of a system or device that can include both electrically large fast multipole method (FMM) elements, and electrically small QR elements. The system or device is setup as an oct-tree structure that can include regions of both the FMM type and the QR type. An iterative solver is then used to determine a first matrix vector product for any electrically large elements, and a second matrix vector product for any electrically small elements that are included in the structure. These matrix vector products for the electrically large elements and the electrically small elements are combined, and a net delta for a combination of the matrix vector products is determined. The iteration continues until a net delta is obtained that is within predefined limits. The matrix vector products that were last obtained are used to solve for the desired parameter.
Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.
Wuest, W; May, M S; Brand, M; Bayerl, N; Krauss, A; Uder, M; Lell, M
2015-10-01
Metal artifacts from dental fillings and other devices degrade image quality and may compromise the detection and evaluation of lesions in the oral cavity and oropharynx by CT. The aim of this study was to evaluate the effect of iterative metal artifact reduction on CT of the oral cavity and oropharynx. Data from 50 consecutive patients with metal artifacts from dental hardware were reconstructed with standard filtered back-projection, linear interpolation metal artifact reduction (LIMAR), and iterative metal artifact reduction. The image quality of sections that contained metal was analyzed for the severity of artifacts and diagnostic value. A total of 455 sections (mean ± standard deviation, 9.1 ± 4.1 sections per patient) contained metal and were evaluated with each reconstruction method. Sections without metal were not affected by the algorithms and demonstrated image quality identical to each other. Of these sections, 38% were considered nondiagnostic with filtered back-projection, 31% with LIMAR, and only 7% with iterative metal artifact reduction. Thirty-three percent of the sections had poor image quality with filtered back-projection, 46% with LIMAR, and 10% with iterative metal artifact reduction. Thirteen percent of the sections with filtered back-projection, 17% with LIMAR, and 22% with iterative metal artifact reduction were of moderate image quality, 16% of the sections with filtered back-projection, 5% with LIMAR, and 30% with iterative metal artifact reduction were of good image quality, and 1% of the sections with LIMAR and 31% with iterative metal artifact reduction were of excellent image quality. Iterative metal artifact reduction yields the highest image quality in comparison with filtered back-projection and linear interpolation metal artifact reduction in patients with metal hardware in the head and neck area. © 2015 by American Journal of Neuroradiology.
Chatwani, Ashwin J; Hassan, Sarmina; Rahimi, Salma; Jeronis, Stacey; Dandolu, Vani
2006-01-01
To determine if douching with Water Works device for 1 month can (1) lower or eliminate perceived vaginal odor by subject; (2) have any effects on vaginal ecosystem. Ten women with perceived vaginal odor with or without discharge, douched every day for 4 weeks in an open-label, nonrandomized pilot study. Primary outcome measures included perceived vaginal odor by subject, lactobacilli score from Nugent slide, and acceptance of the Water Works douching system. Secondary outcome included the safety of using this douching device. At week 4, there was improvement in vaginal odor (P=.0006) and there was no significant change in lactobacilli score. Douching with Water Works device is associated with reduction or elimination of vaginal odor without adversely affecting the vaginal ecosystem.
Piloted Flight Simulator Developed for Icing Effects Training
NASA Technical Reports Server (NTRS)
Ratvasky, Thomas P.
2005-01-01
In an effort to expand pilot training methods to avoid icing-related accidents, the NASA Glenn Research Center and Bihrle Applied Research Inc. have developed the Ice Contamination Effects Flight Training Device (ICEFTD). ICEFTD simulates the flight characteristics of the NASA Twin Otter Icing Research Aircraft in a no-ice baseline and in two ice configurations simulating ice-protection-system failures. Key features of the training device are the force feedback in the yoke, the instrument panel and out-the-window graphics, the instructor s workstation, and the portability of the unit.
Density control in ITER: an iterative learning control and robust control approach
NASA Astrophysics Data System (ADS)
Ravensbergen, T.; de Vries, P. C.; Felici, F.; Blanken, T. C.; Nouailletas, R.; Zabeo, L.
2018-01-01
Plasma density control for next generation tokamaks, such as ITER, is challenging because of multiple reasons. The response of the usual gas valve actuators in future, larger fusion devices, might be too slow for feedback control. Both pellet fuelling and the use of feedforward-based control may help to solve this problem. Also, tight density limits arise during ramp-up, due to operational limits related to divertor detachment and radiative collapses. As the number of shots available for controller tuning will be limited in ITER, in this paper, iterative learning control (ILC) is proposed to determine optimal feedforward actuator inputs based on tracking errors, obtained in previous shots. This control method can take the actuator and density limits into account and can deal with large actuator delays. However, a purely feedforward-based density control may not be sufficient due to the presence of disturbances and shot-to-shot differences. Therefore, robust control synthesis is used to construct a robustly stabilizing feedback controller. In simulations, it is shown that this combined controller strategy is able to achieve good tracking performance in the presence of shot-to-shot differences, tight constraints, and model mismatches.
Floris, Patrick; Curtin, Sean; Kaisermayer, Christian; Lindeberg, Anna; Bones, Jonathan
2018-07-01
The compatibility of CHO cell culture medium formulations with all stages of the bioprocess must be evaluated through small-scale studies prior to scale-up for commercial manufacturing operations. Here, we describe the development of a bespoke small-scale device for assessing the compatibility of culture media with a widely implemented upstream viral clearance strategy, high-temperature short-time (HTST) treatment. The thermal stability of undefined medium formulations supplemented with soy hydrolysates was evaluated upon variations in critical HTST processing parameters, namely, holding times and temperatures. Prolonged holding times of 43 s at temperatures of 110 °C did not adversely impact medium quality while significant degradation was observed upon treatment at elevated temperatures (200 °C) for shorter time periods (11 s). The performance of the device was benchmarked against a commercially available mini-pilot HTST system upon treatment of identical formulations on both platforms. Processed medium samples were analyzed by untargeted LC-MS/MS for compositional profiling followed by chemometric evaluation, which confirmed the observed degradation effects caused by elevated holding temperatures but revealed comparable performance of our developed device with the commercial mini-pilot setup. The developed device can assist medium optimization activities by reducing volume requirements relative to commercially available mini-pilot instrumentation and by facilitating fast throughput evaluation of heat-induced effects on multiple medium lots.
Biotelemetry implant volume and weight in rats: A pilot study report
NASA Technical Reports Server (NTRS)
Somps, Chris J.
1994-01-01
This paper reports the results of a pilot study in which a 240-gram rat was implanted for 41 days with biotelemetry devices weighing a total of 36 gm (18 cc). The implanted animal showed no differences in weight gain, food and water consumption, and postnecropsy organ weights when compared to both an unoperated control animal and an animal that underwent surgery but did not receive an implant. The implanted animal also had temperature and activity rhythms similar to those reported using much smaller implants. Thus, this pilot study showed that a 240-gm rat could be implanted with biotelemetry devices weighing nearly 15 percent of body weight without significant changes in health or behavior. A larger study involving more animals and similar implant sizes is recommended.
T-4G Simulator and T-4 Ground Training Devices in USAF Undergraduate Pilot Training.
ERIC Educational Resources Information Center
Woodruff, Robert R.; Smith, James F.
The objective of the project was to investigate the utility of using an A/F37A-T4G T-37 flight simulator within the context of Air Force undergraduate pilot training. Twenty-one subjects, selected from three undergraduate pilot training classes, were given contact flight training in a TP4G/EPT simulator before going to T-37 aircraft for further…
Pilot Scott Horowitz fashions cord loop fasteners for a contingency spacewalk
1997-02-16
S82-E-5597 (17 Feb. 1997) --- Astronaut Scott J. Horowitz at pilot's station works with a hand-fashioned loop fastener device to be used in support of the additional STS-82 Extravehicular Activity (EVA) to service Hubble Space Telescope (HST). Note sketches overhead which were sent by ground controllers to guide the pilot's engineering of the task. This view was taken with an Electronic Still Camera (ESC).
An Assessment of Iterative Reconstruction Methods for Sparse Ultrasound Imaging
Valente, Solivan A.; Zibetti, Marcelo V. W.; Pipa, Daniel R.; Maia, Joaquim M.; Schneider, Fabio K.
2017-01-01
Ultrasonic image reconstruction using inverse problems has recently appeared as an alternative to enhance ultrasound imaging over beamforming methods. This approach depends on the accuracy of the acquisition model used to represent transducers, reflectivity, and medium physics. Iterative methods, well known in general sparse signal reconstruction, are also suited for imaging. In this paper, a discrete acquisition model is assessed by solving a linear system of equations by an ℓ1-regularized least-squares minimization, where the solution sparsity may be adjusted as desired. The paper surveys 11 variants of four well-known algorithms for sparse reconstruction, and assesses their optimization parameters with the goal of finding the best approach for iterative ultrasound imaging. The strategy for the model evaluation consists of using two distinct datasets. We first generate data from a synthetic phantom that mimics real targets inside a professional ultrasound phantom device. This dataset is contaminated with Gaussian noise with an estimated SNR, and all methods are assessed by their resulting images and performances. The model and methods are then assessed with real data collected by a research ultrasound platform when scanning the same phantom device, and results are compared with beamforming. A distinct real dataset is finally used to further validate the proposed modeling. Although high computational effort is required by iterative methods, results show that the discrete model may lead to images closer to ground-truth than traditional beamforming. However, computing capabilities of current platforms need to evolve before frame rates currently delivered by ultrasound equipments are achievable. PMID:28282862
DOE Office of Scientific and Technical Information (OSTI.GOV)
S.R. Hudson; D.A. Monticello; A.H. Reiman
For the (non-axisymmetric) stellarator class of plasma confinement devices to be feasible candidates for fusion power stations it is essential that, to a good approximation, the magnetic field lines lie on nested flux surfaces; however, the inherent lack of a continuous symmetry implies that magnetic islands responsible for breaking the smooth topology of the flux surfaces are guaranteed to exist. Thus, the suppression of magnetic islands is a critical issue for stellarator design, particularly for small aspect ratio devices. Pfirsch-Schluter currents, diamagnetic currents, and resonant coil fields contribute to the formation of magnetic islands, and the challenge is to designmore » the plasma and coils such that these effects cancel. Magnetic islands in free-boundary high-pressure full-current stellarator magnetohydrodynamic equilibria are suppressed using a procedure based on the Princeton Iterative Equilibrium Solver [Reiman and Greenside, Comp. Phys. Comm. 43 (1986) 157] which iterate s the equilibrium equations to obtain the plasma equilibrium. At each iteration, changes to a Fourier representation of the coil geometry are made to cancel resonant fields produced by the plasma. The changes are constrained to preserve certain measures of engineering acceptability and to preserve the stability of ideal kink modes. As the iterations continue, the coil geometry and the plasma simultaneously converge to an equilibrium in which the island content is negligible, the plasma is stable to ideal kink modes, and the coils satisfy engineering constraints. The method is applied to a candidate plasma and coil design for the National Compact Stellarator Experiment [Reiman, et al., Phys. Plasmas 8 (May 2001) 2083].« less
NASA Astrophysics Data System (ADS)
Hudson, S. R.; Monticello, D. A.; Reiman, A. H.; Strickler, D. J.; Hirshman, S. P.; Ku, L.-P.; Lazarus, E.; Brooks, A.; Zarnstorff, M. C.; Boozer, A. H.; Fu, G.-Y.; Neilson, G. H.
2003-10-01
For the (non-axisymmetric) stellarator class of plasma confinement devices to be feasible candidates for fusion power stations it is essential that, to a good approximation, the magnetic field lines lie on nested flux surfaces; however, the inherent lack of a continuous symmetry implies that magnetic islands responsible for breaking the smooth topology of the flux surfaces are guaranteed to exist. Thus, the suppression of magnetic islands is a critical issue for stellarator design, particularly for small aspect ratio devices. Pfirsch-Schlüter currents, diamagnetic currents and resonant coil fields contribute to the formation of magnetic islands, and the challenge is to design the plasma and coils such that these effects cancel. Magnetic islands in free-boundary high-pressure full-current stellarator magnetohydrodynamic equilibria are suppressed using a procedure based on the Princeton Iterative Equilibrium Solver (Reiman and Greenside 1986 Comput. Phys. Commun. 43 157) which iterates the equilibrium equations to obtain the plasma equilibrium. At each iteration, changes to a Fourier representation of the coil geometry are made to cancel resonant fields produced by the plasma. The changes are constrained to preserve certain measures of engineering acceptability and to preserve the stability of ideal kink modes. As the iterations continue, the coil geometry and the plasma simultaneously converge to an equilibrium in which the island content is negligible, the plasma is stable to ideal kink modes, and the coils satisfy engineering constraints. The method is applied to a candidate plasma and coil design for the National Compact Stellarator eXperiment (Reiman et al 2001 Phys. Plasma 8 2083).
EU Development of High Heat Flux Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linke, J.; Lorenzetto, P.; Majerus, P.
2005-04-15
The development of plasma facing components for next step fusion devices in Europe is strongly focused to ITER. Here a wide spectrum of different design options for the divertor target and the first wall have been investigated with tungsten, CFC, and beryllium armor. Electron beam simulation experiments have been used to determine the performance of high heat flux components under ITER specific thermal loads. Beside thermal fatigue loads with power density levels up to 20 MWm{sup -2}, off-normal events are a serious concern for the lifetime of plasma facing components. These phenomena are expected to occur on a time scalemore » of a few milliseconds (plasma disruptions) or several hundred milliseconds (vertical displacement events) and have been identified as a major source for the production of neutron activated metallic or tritium enriched carbon dust which is of serious importance from a safety point of view.The irradiation induced material degradation is another critical concern for future D-T-burning fusion devices. In ITER the integrated neutron fluence to the first wall and the divertor armour will remain in the order of 1 dpa and 0.7 dpa, respectively. This value is low compared to future commercial fusion reactors; nevertheless, a nonnegligible degradation of the materials has been detected, both for mechanical and thermal properties, in particular for the thermal conductivity of carbon based materials. Beside the degradation of individual material properties, the high heat flux performance of actively cooled plasma facing components has been investigated under ITER specific thermal and neutron loads.« less
2014-01-01
Background According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). Methods The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. Results The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. Conclusions The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a standards-compliant development of small and medium-sized medical software can be carried out by a small team with limited resources in a clinical setting. This is of particular relevance as the upcoming revision of the Medical Device Directive is expected to harmonize and tighten the current legal requirements for all European in-house manufacturers. PMID:24655818
Höss, Angelika; Lampe, Christian; Panse, Ralf; Ackermann, Benjamin; Naumann, Jakob; Jäkel, Oliver
2014-03-21
According to the latest amendment of the Medical Device Directive standalone software qualifies as a medical device when intended by the manufacturer to be used for medical purposes. In this context, the EN 62304 standard is applicable which defines the life-cycle requirements for the development and maintenance of medical device software. A pilot project was launched to acquire skills in implementing this standard in a hospital-based environment (in-house manufacture). The EN 62304 standard outlines minimum requirements for each stage of the software life-cycle, defines the activities and tasks to be performed and scales documentation and testing according to its criticality. The required processes were established for the pre-existent decision-support software FlashDumpComparator (FDC) used during the quality assurance of treatment-relevant beam parameters. As the EN 62304 standard implicates compliance with the EN ISO 14971 standard on the application of risk management to medical devices, a risk analysis was carried out to identify potential hazards and reduce the associated risks to acceptable levels. The EN 62304 standard is difficult to implement without proper tools, thus open-source software was selected and integrated into a dedicated development platform. The control measures yielded by the risk analysis were independently implemented and verified, and a script-based test automation was retrofitted to reduce the associated test effort. After all documents facilitating the traceability of the specified requirements to the corresponding tests and of the control measures to the proof of execution were generated, the FDC was released as an accessory to the HIT facility. The implementation of the EN 62304 standard was time-consuming, and a learning curve had to be overcome during the first iterations of the associated processes, but many process descriptions and all software tools can be re-utilized in follow-up projects. It has been demonstrated that a standards-compliant development of small and medium-sized medical software can be carried out by a small team with limited resources in a clinical setting. This is of particular relevance as the upcoming revision of the Medical Device Directive is expected to harmonize and tighten the current legal requirements for all European in-house manufacturers.
NASA Technical Reports Server (NTRS)
Waller, M. C.
1976-01-01
An electro-optical device called an oculometer which tracks a subject's lookpoint as a time function has been used to collect data in a real-time simulation study of instrument landing system (ILS) approaches. The data describing the scanning behavior of a pilot during the instrument approaches have been analyzed by use of a stepwise regression analysis technique. A statistically significant correlation between pilot workload, as indicated by pilot ratings, and scanning behavior has been established. In addition, it was demonstrated that parameters derived from the scanning behavior data can be combined in a mathematical equation to provide a good representation of pilot workload.
Chatwani, Ashwin J.; Hassan, Sarmina; Rahimi, Salma; Jeronis, Stacey; Dandolu, Vani
2006-01-01
Objective. To determine if douching with Water Works device for 1 month can (1) lower or eliminate perceived vaginal odor by subject; (2) have any effects on vaginal ecosystem. Methods. Ten women with perceived vaginal odor with or without discharge, douched every day for 4 weeks in an open-label, nonrandomized pilot study. Primary outcome measures included perceived vaginal odor by subject, lactobacilli score from Nugent slide, and acceptance of the Water Works douching system. Secondary outcome included the safety of using this douching device. Results. At week 4, there was improvement in vaginal odor (P = .0006) and there was no significant change in lactobacilli score. Conclusion. Douching with Water Works device is associated with reduction or elimination of vaginal odor without adversely affecting the vaginal ecosystem. PMID:17485816
Conceptual design of the ITER fast-ion loss detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia-Munoz, M., E-mail: mgm@us.es; Ayllon-Guerola, J.; Galdon, J.
2016-11-15
A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cmmore » outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.« less
Iterative Code-Aided ML Phase Estimation and Phase Ambiguity Resolution
NASA Astrophysics Data System (ADS)
Wymeersch, Henk; Moeneclaey, Marc
2005-12-01
As many coded systems operate at very low signal-to-noise ratios, synchronization becomes a very difficult task. In many cases, conventional algorithms will either require long training sequences or result in large BER degradations. By exploiting code properties, these problems can be avoided. In this contribution, we present several iterative maximum-likelihood (ML) algorithms for joint carrier phase estimation and ambiguity resolution. These algorithms operate on coded signals by accepting soft information from the MAP decoder. Issues of convergence and initialization are addressed in detail. Simulation results are presented for turbo codes, and are compared to performance results of conventional algorithms. Performance comparisons are carried out in terms of BER performance and mean square estimation error (MSEE). We show that the proposed algorithm reduces the MSEE and, more importantly, the BER degradation. Additionally, phase ambiguity resolution can be performed without resorting to a pilot sequence, thus improving the spectral efficiency.
Latency in Visionic Systems: Test Methods and Requirements
NASA Technical Reports Server (NTRS)
Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.
2005-01-01
A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.
Carbon charge exchange analysis in the ITER-like wall environment.
Menmuir, S; Giroud, C; Biewer, T M; Coffey, I H; Delabie, E; Hawkes, N C; Sertoli, M
2014-11-01
Charge exchange spectroscopy has long been a key diagnostic tool for fusion plasmas and is well developed in devices with Carbon Plasma-Facing Components. Operation with the ITER-like wall at JET has resulted in changes to the spectrum in the region of the Carbon charge exchange line at 529.06 nm and demonstrates the need to revise the core charge exchange analysis for this line. An investigation has been made of this spectral region in different plasma conditions and the revised description of the spectral lines to be included in the analysis is presented.
Applications of pilot scanning behavior to integrated display research
NASA Technical Reports Server (NTRS)
Waller, M. C.
1977-01-01
The oculometer is an electrooptical device designed to measure pilot scanning behavior during instrument approaches and landing operations. An overview of some results from a simulation study is presented to illustrate how information from the oculometer installed in a visual motion simulator, combined with measures of performance and control input data, can provide insight into the behavior and tactics of individual pilots during instrument approaches. Differences in measured behavior of the pilot subjects are pointed out; these differences become apparent in the way the pilots distribute their visual attention, in the amount of control activity, and in selected performance measures. Some of these measured differences have diagnostic implications, suggesting the use of the oculometer along with performance measures as a pilot training tool.
14 CFR 135.347 - Pilots: Initial, transition, upgrade, and differences flight training.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the aircraft simulator or training device; and (2) A flight check in the aircraft or a check in the... differences flight training. 135.347 Section 135.347 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... flight training. (a) Initial, transition, upgrade, and differences training for pilots must include...
14 CFR 135.347 - Pilots: Initial, transition, upgrade, and differences flight training.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the aircraft simulator or training device; and (2) A flight check in the aircraft or a check in the... differences flight training. 135.347 Section 135.347 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... flight training. (a) Initial, transition, upgrade, and differences training for pilots must include...
14 CFR 135.347 - Pilots: Initial, transition, upgrade, and differences flight training.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the aircraft simulator or training device; and (2) A flight check in the aircraft or a check in the... differences flight training. 135.347 Section 135.347 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... flight training. (a) Initial, transition, upgrade, and differences training for pilots must include...
14 CFR 135.347 - Pilots: Initial, transition, upgrade, and differences flight training.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the aircraft simulator or training device; and (2) A flight check in the aircraft or a check in the... differences flight training. 135.347 Section 135.347 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... flight training. (a) Initial, transition, upgrade, and differences training for pilots must include...
14 CFR 135.347 - Pilots: Initial, transition, upgrade, and differences flight training.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the aircraft simulator or training device; and (2) A flight check in the aircraft or a check in the... differences flight training. 135.347 Section 135.347 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... flight training. (a) Initial, transition, upgrade, and differences training for pilots must include...
Noise tolerant illumination optimization applied to display devices
NASA Astrophysics Data System (ADS)
Cassarly, William J.; Irving, Bruce
2005-02-01
Display devices have historically been designed through an iterative process using numerous hardware prototypes. This process is effective but the number of iterations is limited by the time and cost to make the prototypes. In recent years, virtual prototyping using illumination software modeling tools has replaced many of the hardware prototypes. Typically, the designer specifies the design parameters, builds the software model, predicts the performance using a Monte Carlo simulation, and uses the performance results to repeat this process until an acceptable design is obtained. What is highly desired, and now possible, is to use illumination optimization to automate the design process. Illumination optimization provides the ability to explore a wider range of design options while also providing improved performance. Since Monte Carlo simulations are often used to calculate the system performance but those predictions have statistical uncertainty, the use of noise tolerant optimization algorithms is important. The use of noise tolerant illumination optimization is demonstrated by considering display device designs that extract light using 2D paint patterns as well as 3D textured surfaces. A hybrid optimization approach that combines a mesh feedback optimization with a classical optimizer is demonstrated. Displays with LED sources and cold cathode fluorescent lamps are considered.
STS-44 MS Musgrave assists Pilot Henricks with DSO 478 LBNP device on middeck
NASA Technical Reports Server (NTRS)
1991-01-01
STS-44 Mission Specialist (MS) F. Story Musgrave assists Pilot Terence T. Henricks with Detailed Supplementary Objective (DSO) 478, Inflight Lower Body Negative Pressure (LBNP), equipment on the middeck of Atlantis, Orbiter Vehicle (OV) 104. Sensors are secured on Henricks' chest and are connected to a monitoring device. Cables freefloat around the crewmembers. A SONY Walkman and headset drift above Musgrave's head and in front of the starboard wall-mounted sleep restraints. Several banners representing the crewmembers alma maters are displayed on the starboard wall including Rutgers, CCNY, and Auburn.
A head-up display format for transport aircraft approach and landing
NASA Technical Reports Server (NTRS)
Bray, R. S.; Scott, B. C.
1981-01-01
An electronic flight-guidance display format was designed for use in evaluations of the collimated head-up display concept applied to transport aircraft landing. In the design process of iterative evaluation and modification, some general principles, or guidelines, applicable to electronic flight displays were suggested. The usefulness of an indication of instantaneous inertial flightpath was clearly demonstrated. Evaluator pilot acceptance of the unfamiliar display concepts was very positive when careful attention was given to indoctrination and training.
ERIC Educational Resources Information Center
Zebehazy, Kim T.; Zimmerman, George J.; Bowers, Alex R.; Luo, Gang; Peli, Eli
2005-01-01
In addition to their restricted peripheral fields, persons with retinitis pigmentosa (RP) report significant problems seeing in low levels of illumination, which causes difficulty with night travel. Several devices have been developed to support the visual needs of persons who have night blindness. These devices include wide-angle flashlights,…
NASA Astrophysics Data System (ADS)
Tour, James M.; Schumm, Jeffrey S.; Pearson, Darren L.
1994-06-01
Described is the synthesis of oligo (2-ethylphenylene ethynylene)s and oligo (2-(3'ethylheptyl) phenylene ethynylene)s via an iterative divergent convergent approach. Synthesized were the monomer, dimer, tetramer, and octamer of the ethyl derivative and the monomer, dimer, tetramer, octamer, and 16-mer of the ethylheptyl derivative. The 16-mer is 128 A long. At each stage in the iteration, the length of the framework doubles. Only three sets of reaction conditions are needed for the entire iterative synthetic sequence; an iodination, a protodesilylation, and a Pd/Cu-catalyzed cross coupling. The oligomers were characterized spectroscopically and by mass spectrometry. The optical properties are presented which show the stage of optical absorbance saturation. The size exclusion chromatography values for the number average weights, relative to polystyrene, illustrate the tremendous differences in the hydrodynamic volume of these rigid rod oligomers verses the random coils of polystyrene. These differences become quite apparent at the octamer stage. These oligomers may act as molecular wires in molecular electronic devices and they also serve as useful models for understanding related bulk polymers.
Conceptual Design of the ITER Plasma Control System
NASA Astrophysics Data System (ADS)
Snipes, J. A.
2013-10-01
The conceptual design of the ITER Plasma Control System (PCS) has been approved and the preliminary design has begun for the 1st plasma PCS. This is a collaboration of many plasma control experts from existing devices to design and test plasma control techniques applicable to ITER on existing machines. The conceptual design considered all phases of plasma operation, ranging from non-active H/He plasmas through high fusion gain inductive DT plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture can satisfy the demands of the ITER Research Plan. The PCS will control plasma equilibrium and density, plasma heat exhaust, a range of MHD instabilities (including disruption mitigation), and the non-inductive current profile required to maintain stable steady-state scenarios. The PCS architecture requires sophisticated shared actuator management and event handling systems to prioritize control goals, algorithms, and actuators according to dynamic control needs and monitor plasma and plant system events to trigger automatic changes in the control algorithms or operational scenario, depending on real-time operating limits and conditions.
Installation and Testing of ITER Integrated Modeling and Analysis Suite (IMAS) on DIII-D
NASA Astrophysics Data System (ADS)
Lao, L.; Kostuk, M.; Meneghini, O.; Smith, S.; Staebler, G.; Kalling, R.; Pinches, S.
2017-10-01
A critical objective of the ITER Integrated Modeling Program is the development of IMAS to support ITER plasma operation and research activities. An IMAS framework has been established based on the earlier work carried out within the EU. It consists of a physics data model and a workflow engine. The data model is capable of representing both simulation and experimental data and is applicable to ITER and other devices. IMAS has been successfully installed on a local DIII-D server using a flexible installer capable of managing the core data access tools (Access Layer and Data Dictionary) and optionally the Kepler workflow engine and coupling tools. A general adaptor for OMFIT (a workflow engine) is being built for adaptation of any analysis code to IMAS using a new IMAS universal access layer (UAL) interface developed from an existing OMFIT EU Integrated Tokamak Modeling UAL. Ongoing work includes development of a general adaptor for EFIT and TGLF based on this new UAL that can be readily extended for other physics codes within OMFIT. Work supported by US DOE under DE-FC02-04ER54698.
Digital micromirror device as amplitude diffuser for multiple-plane phase retrieval
NASA Astrophysics Data System (ADS)
Abregana, Timothy Joseph T.; Hermosa, Nathaniel P.; Almoro, Percival F.
2017-06-01
Previous implementations of the phase diffuser used in the multiple-plane phase retrieval method included a diffuser glass plate with fixed optical properties or a programmable yet expensive spatial light modulator. Here a model for phase retrieval based on a digital micromirror device as amplitude diffuser is presented. The technique offers programmable, convenient and low-cost amplitude diffuser for a non-stagnating iterative phase retrieval. The technique is demonstrated in the reconstructions of smooth object wavefronts.
Commercial vehicle (CV) retrofit safety device (RSD) kits project.
DOT National Transportation Integrated Search
2014-07-01
Retrofit Safety Device (RSD) kits were developed and deployed on commercial vehicles as part of the U.S. DOT Connected Vehicle Safety Pilot to gain insight into the unique aspects of deploying connected vehicle technology in a commercial vehicle envi...
The influence of the Re-Link Trainer on gait symmetry in healthy adults.
Ward, Sarah; Wiedemann, Lukas; Stinear, Cathy; Stinear, James; McDaid, Andrew
2017-07-01
Walking function post-stroke is characterized by asymmetries in gait cycle parameters and joint kinematics. The Re-Link Trainer is designed to provide kinematic constraint to the paretic lower limb, to guide a physiologically normal and symmetrical gait pattern. The purpose of this pilot study was to assess the immediate influence of the Re-Link Trainer on measures of gait symmetry in healthy adults. Participants demonstrated a significantly lower cadence and a 62% reduction in walking speed in the Re-Link Trainer compared to normal walking. The step length ratio had a significant increase from 1.0 during normal walking to 2.5 when walking in the Re-Link Trainer. The results from this pilot study suggest in its current iteration the Re-Link Trainer imposes an asymmetrical constraint on lower limb kinematics.
NASA Astrophysics Data System (ADS)
Wong, N.; Grace, J. M.; Liang, J.; Owyang, S.; Storrs, A.; Zhou, J.; Rothschild, L. J.; Gentry, D.
2014-12-01
Life acclimated to harsh conditions is frequently difficult to study using normal lab techniques and conventional equipment. Simplified studies using in-lab 'simulated' extreme environments, such as UV bulbs or cold blocks, are manually intensive, error-prone, and lose many complexities of the microbe/environment interaction. We have built a prototype instrument to address this dilemma by allowing automated iterations of microbial cultures to be subject to combinations of modular environmental pressures such as heat, radiation, and chemical exposure. The presence of multiple sensors allows the state of the culture and internal environment to be continuously monitored and adjusted in response.Our first prototype showed successful iterations of microbial growth and thermal exposure. Our second prototype, presented here, performs an demonstration of repeated exposure of Escherichia coli to ultraviolet radiation, a well-established procedure. As the E. coli becomes more resistant to ultraviolet radiation, the device detects their increased survival and growth and increases the dosage accordingly. Calibration data for the instrument was generated by performing the same proof-of-concept exposure experiment, at a smaller scale, by hand. Current performance data indicates that our finalized instrument will have the ability to run hundreds of iterations with multiple selection pressures. The automated sensing and adaptive exposure that the device provides will inform the challenges of managing and culturing life tailored to uncommon environmental stresses. We have designed this device to be flexible, extensible, low-cost and easy to reproduce. We hope that it enter wide use as a tool for conducting scalable studies of the interaction between extremophiles and multiple environmental stresses, and potentially for generating artificial extremophiles as analogues for life we might find in extreme environments here on Earth or elsewhere.
NASA Astrophysics Data System (ADS)
Hudson, S. R.; Monticello, D. A.; Reiman, A. H.; Strickler, D. J.; Hirshman, S. P.
2003-06-01
For the (non-axisymmetric) stellarator class of plasma confinement devices to be feasible candidates for fusion power stations it is essential that, to a good approximation, the magnetic field lines lie on nested flux surfaces; however, the inherent lack of a continuous symmetry implies that magnetic islands are guaranteed to exist. Magnetic islands break the smooth topology of nested flux surfaces and chaotic field lines result when magnetic islands overlap. An analogous case occurs with 11/2-dimension Hamiltonian systems where resonant perturbations cause singularities in the transformation to action-angle coordinates and destroy integrability. The suppression of magnetic islands is a critical issue for stellarator design, particularly for small aspect ratio devices. Techniques for `healing' vacuum fields and fixed-boundary plasma equilibria have been developed, but what is ultimately required is a procedure for designing stellarators such that the self-consistent plasma equilibrium currents and the coil currents combine to produce an integrable magnetic field, and such a procedure is presented here for the first time. Magnetic islands in free-boundary full-pressure full-current stellarator magnetohydrodynamic equilibria are suppressed using a procedure based on the Princeton Iterative Equilibrium Solver [A.H.Reiman & H.S.Greenside, Comp. Phys. Comm., 43:157, 1986.] which iterates the equilibrium equations to obtain the plasma equilibrium. At each iteration, changes to a Fourier representation of the coil geometry are made to cancel resonant fields produced by the plasma. As the iterations continue, the coil geometry and the plasma simultaneously converge to an equilibrium in which the island content is negligible. The method is applied to a candidate plasma and coil design for the National Compact Stellarator eXperiment [G.H.Neilson et.al., Phys. Plas., 7:1911, 2000.].
Research on computer aided testing of pilot response to critical in-flight events
NASA Technical Reports Server (NTRS)
Giffin, W. C.; Rockwell, T. H.; Smith, P. J.
1984-01-01
Experiments on pilot decision making are described. The development of models of pilot decision making in critical in flight events (CIFE) are emphasized. The following tests are reported on the development of: (1) a frame system representation describing how pilots use their knowledge in a fault diagnosis task; (2) assessment of script norms, distance measures, and Markov models developed from computer aided testing (CAT) data; and (3) performance ranking of subject data. It is demonstrated that interactive computer aided testing either by touch CRT's or personal computers is a useful research and training device for measuring pilot information management in diagnosing system failures in simulated flight situations. Performance is dictated by knowledge of aircraft sybsystems, initial pilot structuring of the failure symptoms and efficient testing of plausible causal hypotheses.
DIII-D accomplishments and plans in support of fusion next steps
Buttery, R. J; Eidietis, N.; Holcomb, C.; ...
2013-06-01
DIII-D is using its flexibility and diagnostics to address the critical science required to enable next step fusion devices. We have adapted operating scenarios for ITER to low torque and are now being optimized for transport. Three ELM mitigation scenarios have been developed to near-ITER parameters. New control techniques are managing the most challenging plasma instabilities. Disruption mitigation tools show promising dissipation strategies for runaway electrons and heat load. An off axis neutral beam upgrade has enabled sustainment of high βN capable steady state regimes. Divertor research is identifying the challenge, physics and candidate solutions for handling the hot plasmamore » exhaust with notable progress in heat flux reduction using the snowflake configuration. Our work is helping optimize design choices and prepare the scientific tools for operation in ITER, and resolve key elements of the plasma configuration and divertor solution for an FNSF.« less
The Effect of Feedback on the Accuracy of Checklist Completion during Instrument Flight Training
ERIC Educational Resources Information Center
Rantz, William G.; Dickinson, Alyce M.; Sinclair, Gilbert A.; Van Houten, Ron
2009-01-01
This study examined whether pilots completed airplane checklists more accurately when they receive postflight graphic and verbal feedback. Participants were 8 college students who are pilots with an instrument rating. The task consisted of flying a designated flight pattern using a personal computer aviation training device (PCATD). The dependent…
Code of Federal Regulations, 2013 CFR
2013-01-01
... simulator or training device; and (2) A flight check in the aircraft or a check in the simulator or training..., requalification, and differences flight training. 91.1103 Section 91.1103 Aeronautics and Space FEDERAL AVIATION... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1103 Pilots: Initial...
Code of Federal Regulations, 2014 CFR
2014-01-01
... simulator or training device; and (2) A flight check in the aircraft or a check in the simulator or training..., requalification, and differences flight training. 91.1103 Section 91.1103 Aeronautics and Space FEDERAL AVIATION... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1103 Pilots: Initial...
Code of Federal Regulations, 2011 CFR
2011-01-01
... simulator or training device; and (2) A flight check in the aircraft or a check in the simulator or training..., requalification, and differences flight training. 91.1103 Section 91.1103 Aeronautics and Space FEDERAL AVIATION... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1103 Pilots: Initial...
Code of Federal Regulations, 2012 CFR
2012-01-01
... simulator or training device; and (2) A flight check in the aircraft or a check in the simulator or training..., requalification, and differences flight training. 91.1103 Section 91.1103 Aeronautics and Space FEDERAL AVIATION... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1103 Pilots: Initial...
Code of Federal Regulations, 2010 CFR
2010-01-01
... simulator or training device; and (2) A flight check in the aircraft or a check in the simulator or training..., requalification, and differences flight training. 91.1103 Section 91.1103 Aeronautics and Space FEDERAL AVIATION... OPERATING AND FLIGHT RULES Fractional Ownership Operations Program Management § 91.1103 Pilots: Initial...
Using "Swivl" Robotic Technology in Teacher Education Preparation: A Pilot Study
ERIC Educational Resources Information Center
Franklin, Robin Kesterson; O'Neill Mitchell, Justin; Walters, Kari Siko; Livingston, Beth; Lineberger, Matthew Blake; Putman, Cynthia; Yarborough, Reba; Karges-Bone, Linda
2018-01-01
Based on requirements to promote for reflective practice, both CAEP and edTPA suggest adding a video component to clinical practice. This qualitative pilot study evaluated "Swivl" as that potential recording technological device for clinical practice. During a clinical practice cycle at a private university in the southeastern region of…
STS-42 Payload Specialist Bondar checks Pilot Oswald's blood flow on middeck
NASA Technical Reports Server (NTRS)
1992-01-01
STS-42 Payload Specialist Roberta L. Bondar monitors Pilot Stephen S. Oswald's blood flow on the middeck of Discovery, Orbiter Vehicle (OV) 103. Bondar holds a device just above Oswald's ear and analyzes reading displayed on output module on her right. Behind the two crewmembers is the sleep station.
AN EXPERIMENTAL ASSESSMENT OF A GROUND PILOT TRAINER IN GENERAL AVIATION.
ERIC Educational Resources Information Center
BUTLER, E. DEAN; LANIER, H. MILLER
AN EXPERIMENT WAS CONDUCTED BY MIDDLE TENNESSEE STATE UNIVERSITY TO ASSESS THE EFFECTIVENESS OF A GROUND PILOT TRAINER USED TO DEVELOP PRIMARY AND INSTRUMENT FLIGHT PROFICIENCIES. THE STUDY REQUIRED DIFFERENTIAL USE OF THE DEVICE WITH THREE GROUPS OF CANDIDATES, AND COMPARISON OF TRAINING PROGRESS AND ATTAINED PROFICIENCY VERSUS THAT OF GROUP OF…
Development and Utility of a Piloted Flight Simulator for Icing Effects Training
NASA Technical Reports Server (NTRS)
Ratvasky, Thomas P.; Ranaudo, Richard J.; Barnhart, Billy P.; Dickes, Edward G.; Gingras, David R.
2003-01-01
A piloted flight simulator called the Ice Contamination Effects Flight Training Device (ICEFTD), which uses low cost desktop components and a generic cockpit replication is being developed. The purpose of this device is to demonstrate the effectiveness of its use for training pilots to recognize and recover from aircraft handling anomalies that result from airframe ice formations. High-fidelity flight simulation models for various baseline (non-iced) and iced configurations were developed from wind tunnel tests of a subscale DeHavilland DHC-6 Twin Otter aircraft model. These simulation models were validated with flight test data from the NASA Twin Otter Icing Research Aircraft, which included the effects of ice on wing and tail stall characteristics. These simulation models are being implemented into an ICEFTD that will provide representative aircraft characteristics due to airframe icing. Scenario-based exercises are being constructed to give an operational-flavor to the simulation. Training pilots will learn to recognize iced aircraft characteristics from the baseline, and will practice and apply appropriate recovery procedures to a handling event.
Kang, Seung-Gul; Kang, Jae Myeong; Cho, Seong-Jin; Ko, Kwang-Pil; Lee, Yu Jin; Lee, Heon-Jeong; Kim, Leen; Winkelman, John W.
2017-01-01
Study Objectives: The use of telemedicine with a mobile application (MA) and a wearable device (WD) for the management of sleep disorders has recently received considerable attention. We designed an MA synchronizable with a WD for insomnia treatment. Our pilot study determined the efficacy of simplified group cognitive behavioral therapy for insomnia (CBT-I) delivered using our MA and assessed participant adherence to and satisfaction with the device. Methods: The efficacy of the CBT-I using MA (CBT-I-MA) was assessed by comparing sleep variables (sleep efficiency [SE], Insomnia Severity Index [ISI], and Pittsburgh Sleep Quality Inventory [PSQI] scores) before and after a 4-week treatment protocol in 19 patients with insomnia disorder patients. SE was assessed using a sleep diary, actigraphy, and the PSQI. Results: The intervention significantly improved all three measures of SE (P < .05), and the response rate to treatment was high (94.7%). Total ISI and PSQI scores and sleep latency, as measured by the sleep diary, improved significantly. Participants showed relatively good adherence to our MA, and sleep diary entries were made on 24.3 ± 3.8 of 28 days. Moreover, 94.7% of the participants reported that our MA was effective for treating insomnia. Conclusions: Our pilot study suggested the clinical usefulness of a CBT-I-MA. We expect that our findings will lead to further development and replication studies of CBT-I-MA. Citation: Kang SG, Kang JM, Cho SJ, Ko KP, Lee YJ, Lee HJ, Kim L, Winkelman JW. Cognitive behavioral therapy using a mobile application synchronizable with wearable devices for insomnia treatment: a pilot study. J Clin Sleep Med. 2017;13(4):633–640. PMID:28162145
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandes, Ana; Pereira, Rita C.; Sousa, Jorge
The Instituto de Plasmas e Fusao Nuclear (IPFN) has developed dedicated re-configurable modules based on field programmable gate array (FPGA) devices for several nuclear fusion machines worldwide. Moreover, new Advanced Telecommunication Computing Architecture (ATCA) based modules developed by IPFN are already included in the ITER catalogue. One of the requirements for re-configurable modules operating in future nuclear environments including ITER is the remote update capability. Accordingly, this work presents an alternative method for FPGA remote programing to be implemented in new ATCA based re-configurable modules. FPGAs are volatile devices and their programming code is usually stored in dedicated flash memoriesmore » for properly configuration during module power-on. The presented method is capable to store new FPGA codes in Serial Peripheral Interface (SPI) flash memories using the PCIexpress (PCIe) network established on the ATCA back-plane, linking data acquisition endpoints and the data switch blades. The method is based on the Xilinx Quick Boot application note, adapted to PCIe protocol and ATCA based modules. (authors)« less
Kinetic turbulence simulations at extreme scale on leadership-class systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Bei; Ethier, Stephane; Tang, William
2013-01-01
Reliable predictive simulation capability addressing confinement properties in magnetically confined fusion plasmas is critically-important for ITER, a 20 billion dollar international burning plasma device under construction in France. The complex study of kinetic turbulence, which can severely limit the energy confinement and impact the economic viability of fusion systems, requires simulations at extreme scale for such an unprecedented device size. Our newly optimized, global, ab initio particle-in-cell code solving the nonlinear equations underlying gyrokinetic theory achieves excellent performance with respect to "time to solution" at the full capacity of the IBM Blue Gene/Q on 786,432 cores of Mira at ALCFmore » and recently of the 1,572,864 cores of Sequoia at LLNL. Recent multithreading and domain decomposition optimizations in the new GTC-P code represent critically important software advances for modern, low memory per core systems by enabling routine simulations at unprecedented size (130 million grid points ITER-scale) and resolution (65 billion particles).« less
Code of Federal Regulations, 2014 CFR
2014-01-01
... providing training in a flight simulation training device, have received training and evaluation within the... motion limitations of simulation; (D) Minimum equipment requirements for each curriculum; and (E) The maneuvers that will be demonstrated in the flight simulation training device. (b) An applicant for a pilot...
14 CFR 61.1 - Applicability and definitions.
Code of Federal Regulations, 2014 CFR
2014-01-01
....2. Aeronautical experience means pilot time obtained in an aircraft, flight simulator, or flight... from an authorized instructor in an aircraft, flight simulator, or flight training device; or (iii) Gives training as an authorized instructor in an aircraft, flight simulator, or flight training device...
The "stall barrier" as a new preventive in general aviation accidents.
DOT National Transportation Integrated Search
1966-09-01
An elementary device, actuated by the conventional stall warning vane, is described which can be inexpensively installed in any aircraft. The new device, the Stall Barrier, prevents stalls through (1) warning the pilot through the 'touch sense' of th...
Tirilomis, Theodor; Popov, Aron F; Hanekop, Gunnar G; Braeuer, Anselm; Quintel, Michael; Schoendube, Friedrich A; Friedrich, Martin G
2013-10-01
Renal blood flow (RBF) may vary during cardiopulmonary bypass and low flow may cause insufficient blood supply of the kidney triggering renal failure postoperatively. Still, a valid intraoperative method of continuous RBF measurement is not available. A new catheter combining thermodilution and intravascular Doppler was developed, first calibrated in an in vitro model, and the catheter specific constant was determined. Then, application of the device was evaluated in a pilot study in an adult cardiovascular population. The data of the clinical pilot study revealed high correlation between the flow velocities detected by intravascular Doppler and the RBF measured by thermodilution (Pearson's correlation range: 0.78 to 0.97). In conclusion, the RBF can be measured excellently in real time using the new catheter, even under cardiopulmonary bypass. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
Understanding and predicting the dynamics of tokamak discharges during startup and rampdown
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, G. L.; Politzer, P. A.; Humphreys, D. A.
Understanding the dynamics of plasma startup and termination is important for present tokamaks and for predictive modeling of future burning plasma devices such as ITER. We report on experiments in the DIII-D tokamak that explore the plasma startup and rampdown phases and on the benchmarking of transport models. Key issues have been examined such as plasma initiation and burnthrough with limited inductive voltage and achieving flattop and maximum burn within the technical limits of coil systems and their actuators while maintaining the desired q profile. Successful rampdown requires scenarios consistent with technical limits, including controlled H-L transitions, while avoiding verticalmore » instabilities, additional Ohmic transformer flux consumption, and density limit disruptions. Discharges were typically initiated with an inductive electric field typical of ITER, 0.3 V/m, most with second harmonic electron cyclotron assist. A fast framing camera was used during breakdown and burnthrough of low Z impurity charge states to study the formation physics. An improved 'large aperture' ITER startup scenario was developed, and aperture reduction in rampdown was found to be essential to avoid instabilities. Current evolution using neoclassical conductivity in the CORSICA code agrees with rampup experiments, but the prediction of the temperature and internal inductance evolution using the Coppi-Tang model for electron energy transport is not yet accurate enough to allow extrapolation to future devices.« less
Bioenergetical and Cardiac Adaptations of Pilots to a 24-Hour Team Kart Race.
Durand, Sylvain; Ripamonti, Michael; Rahmani, Abderrahmane; Beaune, Bruno
2015-11-01
This study aimed to evaluate energy expenditure (EE) and heart rate (HR) response in kart pilots to successive driving bouts during a 24-hour team race. Eight adult male pilots (22.8 ± 4.1 years) participated to a team 24-hour speedway kart race in Le Mans (France). They alternatively piloted a 390 cm kart. Each relay was 45 minutes long and each pilot performed 4 relays. For each pilot, mean speeds were calculated from lap-to-lap duration recordings using a telemetric infrared timing device. Heart rate values were recorded continuously on 5-second intervals using a portable cardiometric device. Total energy expenditure (EET) and physical activity ratio (PAR) were determined by accelerometry. To pilot a kart during 45 minutes at a mean speed around 62 km·h induces a 300-kcal EET, corresponding to a 5.6-Mets PAR. This effort is responsive for a 73 b·min increase in HR, from 84.1 ± 7.6 to 157.4 ± 11.0 b·min (82% maximal heart rate intensity). However, during this relay period, HR values seemed independent to mean speed performance and bioenergetical values. Thus, in the context of the 24-hour team race, the variability in effort made during each relay and relay succession did not alter bioenergetical adaptation of pilots to kart driving. The high EE and HR values would be better explained by both emotional stress and environmental constraints such as speedway configuration and vibrations. The way how these factors specifically influence bioenergetical demand, and their relative importance, has to be specified to optimize training procedure and recommendations.
14 CFR 61.64 - Use of a flight simulator and flight training device.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Use of a flight simulator and flight... Ratings and Pilot Authorizations § 61.64 Use of a flight simulator and flight training device. (a) Use of a flight simulator or flight training device. If an applicant for a certificate or rating uses a...
14 CFR 61.64 - Use of a flight simulator and flight training device.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Use of a flight simulator and flight... Ratings and Pilot Authorizations § 61.64 Use of a flight simulator and flight training device. (a) Use of a flight simulator or flight training device. If an applicant for a certificate or rating uses a...
Daley, Matthew F; Goddard, Kristin; McClung, Melissa; Davidson, Arthur; Weiss, Gretchen; Palen, Ted; Nyirenda, Carsie; Platt, Richard; Courtney, Brooke; Reichman, Marsha E
2016-01-01
Medical countermeasures (MCMs) are medical products used during public health emergencies. This study, conducted within the Mini-Sentinel Initiative, sought to develop the patient identification and matching processes necessary to assess safety outcomes for MCMs. A handheld device was used to collect identifying information (e.g., name, birthdate, and sex) from the driver's licenses of 421 individuals presenting for routine care at their primary care medical office. Overall, 374 individuals (88.8%) could be linked to their electronic health data using driver's license information. The device was also pilot-tested at a seasonal influenza immunization clinic: detailed vaccine information (e.g., lot number and manufacturer) was captured with a high degree of accuracy. This investigation demonstrated that a handheld device is a feasible means of collecting patient identity and medical product receipt data. This capacity should be useful for safety surveillance of MCMs, particularly when dispensed in settings outside the traditional health-care delivery system.
Mummah, Sarah A; King, Abby C; Gardner, Christopher D; Sutton, Stephen
2016-08-08
Mobile technology may serve as a cost-effective and scalable tool for delivering behavioral nutrition interventions. This research sought to iteratively develop a theory-driven mobile app, Vegethon, to increase vegetable consumption. Development of Vegethon followed phases outlined by the IDEAS framework: 1) empathize with users (qualitative interviews, n = 18); 2) specify target behavior; 3) ground in behavioral theory; 4) ideate implementation strategies; 5) prototype potential products; 6) gather user feedback (qualitative interviews, n = 14; questionnaire, n = 41); 7) build minimum viable product; and 8) pilot potential efficacy and usability (pilot RCT, n = 17). Findings from each phase informed subsequent phases. The target population that informed intervention development was 18-50 years of age, had BMIs of 28-40 kg/m(2), and lived in the geographical area surrounding Stanford University. A full description of the final version of Vegethon is included in the paper. Qualitative findings that shaped initial intervention conception were: participants' interests in accountability without judgment; their desire for simple and efficient dietary self-monitoring; and the importance of planning meals in advance. Qualitative findings identified during intervention refinement were the need for a focus on vegetable self-monitoring; inclusion of vegetable challenges; simplification of features; advice and inspiration for eating vegetables; reminder notifications; and peer comparison. Pilot RCT findings suggested the initial efficacy, acceptance, and feasibility of the intervention. The final version of Vegethon enabled easy self-monitoring of vegetable consumption and included a range of features designed to engage the user (e.g., surprise challenges; leaderboard; weekly reports). Vegethon was coded for its inclusion of 18 behavior change techniques (BCTs) (e.g., goal setting; feedback; social comparison; prompts/cues; framing/reframing; identity). Vegethon is a theory-based, user-informed mobile intervention that was systematically developed using the IDEAS framework. Vegethon targets increased vegetable consumption among overweight adults and is currently being evaluated in a randomized controlled efficacy trial. Clinical Trials.gov: NCT01826591.
NASA Technical Reports Server (NTRS)
Chase, W. D.
1975-01-01
The calligraphic chromatic projector described was developed to improve the perceived realism of visual scene simulation ('out-the-window visuals'). The optical arrangement of the projector is illustrated and discussed. The device permits drawing 2000 vectors in as many as 500 colors, all above critical flicker frequencies, and use of high scene resolution and brightness at an acceptable level to the pilot, with the maximum system capabilities of 1000 lines and 1000 fL. The device for generating the colors is discussed, along with an experiment conducted to demonstrate potential improvements in performance and pilot opinion. Current research work and future research plans are noted.
Virtual reality 3D headset based on DMD light modulators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernacki, Bruce E.; Evans, Allan; Tang, Edward
We present the design of an immersion-type 3D headset suitable for virtual reality applications based upon digital micro-mirror devices (DMD). Our approach leverages silicon micro mirrors offering 720p resolution displays in a small form-factor. Supporting chip sets allow rapid integration of these devices into wearable displays with high resolution and low power consumption. Applications include night driving, piloting of UAVs, fusion of multiple sensors for pilots, training, vision diagnostics and consumer gaming. Our design is described in which light from the DMD is imaged to infinity and the user’s own eye lens forms a real image on the user’s retina.
Pilot Task Profiles, Human Factors, And Image Realism
NASA Astrophysics Data System (ADS)
McCormick, Dennis
1982-06-01
Computer Image Generation (CIG) visual systems provide real time scenes for state-of-the-art flight training simulators. The visual system reauires a greater understanding of training tasks, human factors, and the concept of image realism to produce an effective and efficient training scene than is required by other types of visual systems. Image realism must be defined in terms of pilot visual information reauirements. Human factors analysis of training and perception is necessary to determine the pilot's information requirements. System analysis then determines how the CIG and display device can best provide essential information to the pilot. This analysis procedure ensures optimum training effectiveness and system performance.
Challenges in standardization of blood pressure measurement at the population level.
Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari
2015-04-10
Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.
Blue Laser Induced Retinal Injury in a Commercial Pilot at 1300 ft.
Gosling, Daniel B; O'Hagan, John B; Quhill, Fahd M
2016-01-01
We report what may be the first evidence-based report of a retinal laser injury to a pilot during commercial flight from a laser device on the ground. Given the significant subjective (blind spot) and objective evidence of focal retinal damage, coupled with the distance involved, we suspect the laser had a radiant power of several watts, known to be injurious to the human retina. An airline pilot presented to our department complaining of a blind spot in the upper left area of his visual field in the right eye (right supero-nasal scotoma) following exposure to a laser beam while performing a landing maneuver of a commercial aircraft. At around 1300 ft (396 m), a blue laser beam from the ground directly entered his right eye, with immediate flash blindness and pain. Spectral domain ocular coherence tomography highlighted a localized area of photoreceptor disruption corresponding to a well demarcated area of hypofluorescence on fundus autofluorescence, representing a focal outer retinal laser injury. Fundus examination a fortnight later revealed a clinically identifiable lesion in the pilot's right eye commensurate with a retinal-laser burn. The case reports highlights the growing threat to the ocular health of airline crew and, potentially, passenger safety due to the lack of regulatory oversight of high powered laser devices obtained from the internet. We strongly believe high powered handheld laser devices should not be in the possession of the general public.
NASA Technical Reports Server (NTRS)
Ranaudo, Richard J.; Martos, Borja; Norton, Bill W.; Gingras, David R.; Barnhart, Billy P.; Ratvasky, Thomas P.; Morelli, Eugene
2011-01-01
The utility of the Icing Contamination Envelope Protection (ICEPro) system for mitigating a potentially hazardous icing condition was evaluated by 29 pilots using the NASA Ice Contamination Effects Flight Training Device (ICEFTD). ICEPro provides real time envelope protection cues and alerting messages on pilot displays. The pilots participating in this test were divided into two groups; a control group using baseline displays without ICEPro, and an experimental group using ICEPro driven display cueing. Each group flew identical precision approach and missed approach procedures with a simulated failure case icing condition. Pilot performance, workload, and survey questionnaires were collected for both groups of pilots. Results showed that real time assessment cues were effective in reducing the number of potentially hazardous upset events and in lessening exposure to loss of control following an incipient upset condition. Pilot workload with the added ICEPro displays was not measurably affected, but pilot opinion surveys showed that real time cueing greatly improved their situation awareness of a hazardous aircraft state.
Laser interference fringe tomography: a novel 3D imaging technique for pathology
NASA Astrophysics Data System (ADS)
Kazemzadeh, Farnoud; Haylock, Thomas M.; Chifman, Lev M.; Hajian, Arsen R.; Behr, Bradford B.; Cenko, Andrew T.; Meade, Jeff T.; Hendrikse, Jan
2011-03-01
Laser interference fringe tomography (LIFT) is within the class of optical imaging devices designed for in vivo and ex vivo medical imaging applications. LIFT is a very simple and cost-effective three-dimensional imaging device with performance rivaling some of the leading three-dimensional imaging devices used for histology. Like optical coherence tomography (OCT), it measures the reflectivity as a function of depth within a sample and is capable of producing three-dimensional images from optically scattering media. LIFT has the potential capability to produce high spectral resolution, full-color images. The optical design of LIFT along with the planned iterations for improvements and miniaturization are presented and discussed in addition to the theoretical concepts and preliminary imaging results of the device.
14 CFR 135.336 - Airline transport pilot certification training program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... (v) Evaluation. (4) If providing training in a flight simulation training device, holds an aircraft type rating for the aircraft represented by the flight simulation training device utilized in the... simulation; (iv) Minimum equipment requirements for each curriculum; and (v) The maneuvers that will be...
14 CFR 61.1 - Applicability and definitions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... of this part: (1) Aeronautical experience means pilot time obtained in an aircraft, flight simulator... simulator, or flight training device; or (iii) Gives training as an authorized instructor in an aircraft, flight simulator, or flight training device. (16) Practical test means a test on the areas of operations...
14 CFR 61.1 - Applicability and definitions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... of this part: (1) Aeronautical experience means pilot time obtained in an aircraft, flight simulator... simulator, or flight training device; or (iii) Gives training as an authorized instructor in an aircraft, flight simulator, or flight training device. (16) Practical test means a test on the areas of operations...
Code of Federal Regulations, 2010 CFR
2010-01-01
... OTHER CERTIFICATED AGENCIES TRAINING CENTERS General § 142.3 Definitions. As used in this part: Advanced Flight Training Device as used in this part, means a flight training device as defined in part 61 of this... program of instruction to obtain pilot certification, qualification, authorization, or currency; (2) A...
Computerization of Mental Health Integration Complexity Scores at Intermountain Healthcare
Oniki, Thomas A.; Rodrigues, Drayton; Rahman, Noman; Patur, Saritha; Briot, Pascal; Taylor, David P.; Wilcox, Adam B.; Reiss-Brennan, Brenda; Cannon, Wayne H.
2014-01-01
Intermountain Healthcare’s Mental Health Integration (MHI) Care Process Model (CPM) contains formal scoring criteria for assessing a patient’s mental health complexity as “mild,” “medium,” or “high” based on patient data. The complexity score attempts to assist Primary Care Physicians in assessing the mental health needs of their patients and what resources will need to be brought to bear. We describe an effort to computerize the scoring. Informatics and MHI personnel collaboratively and iteratively refined the criteria to make them adequately explicit and reflective of MHI objectives. When tested on retrospective data of 540 patients, the clinician agreed with the computer’s conclusion in 52.8% of the cases (285/540). We considered the analysis sufficiently successful to begin piloting the computerized score in prospective clinical care. So far in the pilot, clinicians have agreed with the computer in 70.6% of the cases (24/34). PMID:25954401
Pore, Meenal; Sengeh, David M.; Mugambi, Purity; Purswani, Nuri V.; Sesay, Tom; Arnold, Anna Lena; Tran, Anh-Minh A.; Myers, Ralph
2017-01-01
During the 2014 West African Ebola Virus outbreak it became apparent that the initial response to the outbreak was hampered by limitations in the collection, aggregation, analysis and use of data for intervention planning. As part of the post-Ebola recovery phase, IBM Research Africa partnered with the Port Loko District Health Management Team (DHMT) in Sierra Leone and GOAL Global, to design, implement and deploy a web-based decision support tool for district-level disease surveillance. This paper discusses the design process and the functionality of the first version of the system. The paper presents evaluation results prior to a pilot deployment and identifies features for future iterations. A qualitative assessment of the tool prior to pilot deployment indicates that it improves the timeliness and ease of using data for making decisions at the DHMT level. PMID:29854209
Pitale, Jaswandi Tushar; Bolte, John H
2018-01-01
Cerebral palsy (CP) is a developmental disorder of movement and posture that occurs due to damage to the developing nervous system. As part of therapy, wearable sensors that trigger interactive feedback may provide multi-sensory guidance and motivation. A prototype of a heel-strike real-time feedback system has been developed which records the number of heel strikes during gait and indicates successful heel contact through real-time auditory feedback. The first aim of this feasibility study was to test the prototype accuracy.Since the end user for this device is a child, the device should be esthetically appealing and sufficiently motivating for children to perform repetitive challenging therapeutic movements. The second aim of this study was to collect feedback from the subjects with regard to the device usability and understand if the bell sound used as feedback used was motivating enough for children to continue using the prototype. This would help us in developing the next generation of the device. The prototype was tested with typically developing children and children who have CP. The accuracy in detecting heel strikes was calculated. As part of the study, the subjects were also asked questions to test the device compliance and acceptability of the musical beats with the pediatric population. The device accuracy in identifying heel strikes is 97.44% (95% CI 96.31, 98.88%). The subjects did not show any hesitation to put on the device and the sound feedback motivated them to move. Based on this pilot study, a minimum age limit of 5 years is appropriate and the intervention study should be conducted for no more than 30 min per week. The pilot study showed that a main study can be conducted to test auditory feedback as an intervention to promote motor learning in children who have cerebral palsy. No adverse event or safety issues were reported in the feasibility study.
Automating Microbial Directed Evolution For Bioengineering Applications
NASA Astrophysics Data System (ADS)
Lee, A.; Demachkie, I. S.; Sardesh, N.; Arismendi, D.; Ouandji, C.; Wang, J.; Blaich, J.; Gentry, D.
2016-12-01
From a micro-biology perspective, directed evolution is a technique that uses controlled environmental pressures to select for a desired phenotype. Directed evolution has the distinct advantage over rational design of not needing extensive knowledge of the genome or pathways associated with a microorganism to induce phenotypes. However, there are currently limitations to the applicability of this technique including being time-consuming, error-prone, and dependent on existing assays that may lack selectivity for the given phenotype. The AADEC (Autonomous Adaptive Directed Evolution Chamber) system is a proof-of-concept instrument to automate and improve the technique such that directed evolution can be used more effectively as a general bioengineering tool. A series of tests using the automated system and comparable by-hand survival assay measurements have been carried out using UV-C radiation and Escherichia coli cultures in order to demonstrate the advantages of the AADEC versus traditional implementations of directed evolution such as random mutagenesis. AADEC uses UV-C exposure as both a source of environmental stress and mutagenesis, so in order to evaluate the UV-C tolerance obtained from the cultures, a manual UV-C exposure survival assay was developed alongside the device to compare the survival fractions at a fixed dosage. This survival assay involves exposing E.coli to UV-C radiation using a custom-designed exposure hood to control the flux and dose. Surviving cells are counted then transferred to the next iteration and so on for several iterations to calculate the survival fractions for each exposure iteration. This survival assay primarily serves as a baseline for the AADEC device, allowing quantification of the differences between the AADEC system over the manual approach. The primary data of comparison is survival fractions; this is obtained by optical density and plate counts in the manual assay and by optical density growth curve fits pre- and post-exposure in the automated case. This data can then be compiled to calculate trends over the iterations to characterize increasing UV-C resistance of the E.coli strains. The observed trends are statistically indistinguishable through several iterations from both sources.
Issues and challenges of involving users in medical device development.
Bridgelal Ram, Mala; Grocott, Patricia R; Weir, Heather C M
2008-03-01
User engagement has become a central tenet of health-care policy. This paper reports on a case study in progress that highlights user engagement in the research process in relation to medical device development. To work with a specific group of medical device users to uncover unmet needs, translating these into design concepts, novel technologies and products. To validate a knowledge transfer model that may be replicated for a range of medical device applications and user groups. In depth qualitative case study to elicit and analyse user needs. The focus is on identifying design concepts for medical device applications from unmet needs, and validating these in an iterative feedback loop to the users. The case study has highlighted three interrelated challenges: ensuring unmet needs drive new design concepts and technology development; managing user expectations and managing the research process. Despite the challenges, active participation of users is crucial to developing usable and clinically effective devices.
Frontier of Fusion Research: Path to the Steady State Fusion Reactor by Large Helical Device
NASA Astrophysics Data System (ADS)
Motojima, Osamu
2006-12-01
The ITER, the International Thermonuclear Experimental Reactor, which will be built in Cadarache in France, has finally started this year, 2006. Since the thermal energy produced by fusion reactions divided by the external heating power, i.e., the Q value, will be larger than 10, this is a big step of the fusion research for half a century trying to tame the nuclear fusion for the 6.5 Billion people on the Earth. The source of the Sun's power is lasting steadily and safely for 8 Billion years. As a potentially safe environmentally friendly and economically competitive energy source, fusion should provide a sustainable future energy supply for all mankind for ten thousands of years. At the frontier of fusion research important milestones are recently marked on a long road toward a true prototype fusion reactor. In its own merits, research into harnessing turbulent burning plasmas and thereby controlling fusion reaction, is one of the grand challenges of complex systems science. After a brief overview of a status of world fusion projects, a focus is given on fusion research at the National Institute for Fusion Science (NIFS) in Japan, which is playing a role of the Inter University Institute, the coordinating Center of Excellence for academic fusion research and by the Large Helical Device (LHD), the world's largest superconducting heliotron device, as a National Users' facility. The current status of LHD project is presented focusing on the experimental program and the recent achievements in basic parameters and in steady state operations. Since, its start in a year 1998, a remarkable progress has presently resulted in the temperature of 140 Million degree, the highest density of 500 Thousand Billion/cc with the internal density barrier (IDB) and the highest steady average beta of 4.5% in helical plasma devices and the largest total input energy of 1.6 GJ, in all magnetic confinement fusion devices. Finally, a perspective is given of the ITER Broad Approach program as an integrated part of ITER and Development of Fusion Energy project Agreement. Moreover, the relationship with the NIFS' new parent organization the National Institutes of Natural Sciences and with foreign research institutions is briefly explained.
NASA Astrophysics Data System (ADS)
Jain, P.; Recchia, M.; Cavenago, M.; Fantz, U.; Gaio, E.; Kraus, W.; Maistrello, A.; Veltri, P.
2018-04-01
Neutral beam injection (NBI) for plasma heating and current drive is necessary for International Thermonuclear Experimental reactor (ITER) tokamak. Due to its various advantages, a radio frequency (RF) driven plasma source type was selected as a reference ion source for the ITER heating NBI. The ITER relevant RF negative ion sources are inductively coupled (IC) devices whose operational working frequency has been chosen to be 1 MHz and are characterized by high RF power density (˜9.4 W cm-3) and low operational pressure (around 0.3 Pa). The RF field is produced by a coil in a cylindrical chamber leading to a plasma generation followed by its expansion inside the chamber. This paper recalls different concepts based on which a methodology is developed to evaluate the efficiency of the RF power transfer to hydrogen plasma. This efficiency is then analyzed as a function of the working frequency and in dependence of other operating source and plasma parameters. The study is applied to a high power IC RF hydrogen ion source which is similar to one simplified driver of the ELISE source (half the size of the ITER NBI source).
Air pollution control system research: An iterative approach to developing affordable systems
NASA Technical Reports Server (NTRS)
Watt, Lewis C.; Cannon, Fred S.; Heinsohn, Robert J.; Spaeder, Timothy A.
1995-01-01
This paper describes a Strategic Environmental Research and Development Program (SERDP) funded project led jointly by the Marine Corps Multi-Commodity Maintenance Centers, and the Air and Energy Engineering Research Laboratory (AEERL) of the USEPA. The research focuses on paint booth exhaust minimization using recirculation, and on volatile organic compound (VOC) oxidation by the modules of a hybrid air pollution control system. The research team is applying bench, pilot and full scale systems to accomplish the goals of reduced cost and improved effectiveness of air treatment systems for paint booth exhaust.
A head-up display for low-visibility approach and landing
NASA Technical Reports Server (NTRS)
Bray, R. S.; Scott, B. C.
1981-01-01
An electronic flight-guidance display format was designed for use in evaluations of the collimated head-up display concept in low-visibility landings of transport aircraft. In the design process of iterative evaluation and modification, some general principles, or guidelines, applicable to such flight displays were suggested. The usefulness of an indication of instantaneous inertial flightpath was clearly demonstrated, particularly in low-altitude transition to visual references. Evaluator pilot acceptance of the unfamiliar display concepts was very positive when careful attention was given to indoctrination and training.
Development of implant loading device for animal study about various loading protocol: a pilot study
Yoon, Joon-Ho; Park, Young-Bum; Cho, Yuna; Kim, Chang-Sung; Choi, Seong-Ho; Moon, Hong-Seok; Lee, Keun-Woo
2012-01-01
PURPOSE The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (µε) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study. PMID:23236575
14 CFR 142.54 - Airline transport pilot certification training program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... training in a flight simulation training device— (1) Holds an aircraft type rating for the aircraft represented by the flight simulation training device utilized in the training program and have received... will be demonstrated in the flight simulation training device; and (2) Satisfies the requirements of...
40 CFR 63.987 - Flare requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission Standards for Closed Vent Systems, Control Devices, Recovery Devices and Routing to a Fuel Gas... the additional cycles. (ii) The net heating value of the gas being combusted in a flare shall be..., ultra-violet beam sensor, or infrared sensor) capable of continuously detecting that at least one pilot...
Simulation Evaluation of Pilot Inputs for Real Time Modeling During Commercial Flight Operations
NASA Technical Reports Server (NTRS)
Martos, Borja; Ranaudo, Richard; Oltman, Ryan; Myhre, Nick
2017-01-01
Aircraft dynamics characteristics can only be identified from flight data when the aircraft dynamics are excited sufficiently. A preliminary study was conducted into what types and levels of manual piloted control excitation would be required for accurate Real-Time Parameter IDentification (RTPID) results by commercial airline pilots. This includes assessing the practicality for the pilot to provide this excitation when cued, and to further understand if pilot inputs during various phases of flight provide sufficient excitation naturally. An operationally representative task was evaluated by 5 commercial airline pilots using the NASA Ice Contamination Effects Flight Training Device (ICEFTD). Results showed that it is practical to use manual pilot inputs only as a means of achieving good RTPID in all phases of flight and in flight turbulence conditions. All pilots were effective in satisfying excitation requirements when cued. Much of the time, cueing was not even necessary, as just performing the required task provided enough excitation for accurate RTPID estimation. Pilot opinion surveys reported that the additional control inputs required when prompted by the excitation cueing were easy to make, quickly mastered, and required minimal training.
NASA Technical Reports Server (NTRS)
Young, L. R.
1975-01-01
Preliminary tests and evaluation are presented of pilot performance during landing (flight paths) using computer generated images (video tapes). Psychophysiological factors affecting pilot visual perception were measured. A turning flight maneuver (pitch and roll) was specifically studied using a training device, and the scaling laws involved were determined. Also presented are medical studies (abstracts) on human response to gravity variations without visual cues, acceleration stimuli effects on the semicircular canals, and neurons affecting eye movements, and vestibular tests.
The influence of individualized music on patients in physical restraints: a pilot study.
Janelli, Linda M; Kanski, Genevieve W; Wu, Yow-Wu Bill
This pilot study explored the relationship between listening to preferred music and the behavioral responses of patients who are physically restrained. Thirty patients, ranging in age from 65 to 93, participated in one of three groups. The first group included patients who were out of restraining devices while listening to preferred music. Patients in the second group were out of restraining devices and not exposed to music. The third group comprised patients who were in restraining devices while listening to preferred music. Listening to preferred music had no significant effect on decreasing patients' negative behaviors or on increasing positive behaviors observed during the intervention phase of the study. The higher mean scores for positive behaviors and lower mean scores for negative behaviors for the first group may indicate some benefits to patients who are out of restraints and listening to preferred music.
Using the DSAP Framework to Guide Instructional Design and Technology Integration in BYOD Classrooms
ERIC Educational Resources Information Center
Wasko, Christopher W.
2016-01-01
The purpose of this study was to determine the suitability of the DSAP Framework to guide instructional design and technology integration for teachers piloting a BYOD (Bring Your Own Device) initiative and to measure the impact the initiative had on the amount and type of technology used in pilot classrooms. Quantitative and qualitative data were…
A Pilot and Feasibility Study of Virtual Reality as a Distraction for Children with Cancer
ERIC Educational Resources Information Center
Gershon, Jonathan; Zimand, Elana; Pickering, Melissa; Rothbaum, Barbara Olasov; Hodges, Larry
2004-01-01
Objective: To pilot and test the feasibility of a novel technology to reduce anxiety and pain associated with an invasive medical procedure in children with cancer. Method: Children with cancer (ages 7-19) whose treatment protocols required access of their subcutaneous venous port device (port access) were randomly assigned to a virtual reality…
ERIC Educational Resources Information Center
Conboy, Ian
The Charlton pilot project was one of a number of trials undertaken throughout Australia to bring educational resources to isolated children. In this project, Telecom Australia provided seven small Victorian Higher School Certificate (H.S.C.) schools with two first prototype experimental devices: firstly, a small group terminal and secondly,…
NASA Technical Reports Server (NTRS)
Mironenko, G.
1972-01-01
Programs for the analyses of the free or forced, undamped vibrations of one or two elastically-coupled lumped parameter teams are presented. Bearing nonlinearities, casing and rotor distributed mass and elasticity, rotor imbalance, forcing functions, gyroscopic moments, rotary inertia, and shear and flexural deformations are all included in the system dynamics analysis. All bearings have nonlinear load displacement characteristics, the solution is achieved by iteration. Rotor imbalances allowed by such considerations as pilot tolerances and runouts as well as bearing clearances (allowing concail or cylindrical whirl) determine the forcing function magnitudes. The computer programs first obtain a solution wherein the bearings are treated as linear springs of given spring rates. Then, based upon the computed bearing reactions, new spring rates are predicted and another solution of the modified system is made. The iteration is continued until the changes to bearing spring rates and bearing reactions become negligibly small.
NASA Astrophysics Data System (ADS)
Tokuda, Junichi; Chauvin, Laurent; Ninni, Brian; Kato, Takahisa; King, Franklin; Tuncali, Kemal; Hata, Nobuhiko
2018-04-01
Patient-mounted needle guide devices for percutaneous ablation are vulnerable to patient motion. The objective of this study is to develop and evaluate a software system for an MRI-compatible patient-mounted needle guide device that can adaptively compensate for displacement of the device due to patient motion using a novel image-based automatic device-to-image registration technique. We have developed a software system for an MRI-compatible patient-mounted needle guide device for percutaneous ablation. It features fully-automated image-based device-to-image registration to track the device position, and a device controller to adjust the needle trajectory to compensate for the displacement of the device. We performed: (a) a phantom study using a clinical MR scanner to evaluate registration performance; (b) simulations using intraoperative time-series MR data acquired in 20 clinical cases of MRI-guided renal cryoablations to assess its impact on motion compensation; and (c) a pilot clinical study in three patients to test its feasibility during the clinical procedure. FRE, TRE, and success rate of device-to-image registration were mm, mm, and 98.3% for the phantom images. The simulation study showed that the motion compensation reduced the targeting error for needle placement from 8.2 mm to 5.4 mm (p < 0.0005) in patients under general anesthesia (GA), and from 14.4 mm to 10.0 mm () in patients under monitored anesthesia care (MAC). The pilot study showed that the software registered the device successfully in a clinical setting. Our simulation study demonstrated that the software system could significantly improve targeting accuracy in patients treated under both MAC and GA. Intraprocedural image-based device-to-image registration was feasible.
Development of a virtual flight simulator.
Kuntz Rangel, Rodrigo; Guimarães, Lamartine N F; de Assis Correa, Francisco
2002-10-01
We present the development of a flight simulator that allows the user to interact in a created environment by means of virtual reality devices. This environment simulates the sight of a pilot in an airplane cockpit. The environment is projected in a helmet visor and allows the pilot to see inside as well as outside the cockpit. The movement of the airplane is independent of the movement of the pilot's head, which means that the airplane might travel in one direction while the pilot is looking at a 30 degrees angle with respect to the traveled direction. In this environment, the pilot will be able to take off, fly, and land the airplane. So far, the objects in the environment are geometrical figures. This is an ongoing project, and only partial results are available now.
Towards an internal model in pilot training.
Braune, R J; Trollip, S R
1982-10-01
Optimal decision making requires an information seeking behavior which reflects the comprehension of the overall system dynamics. Research in the area of human monitors in man-machine systems supports the notion of an internal model with built-in expectancies. It is doubtful that the current approach to pilot training helps develop this internal model in the most efficient way. But this is crucial since the role of the pilot is changing to a systems' manager and decision maker. An extension of the behavioral framework of pilot training might help to prepare the pilot better for the increasingly complex flight environment. This extension is based on the theoretical model of schema theory, which evolved out of psychological research. The technological advances in aircraft simulators and in-flight performance measurement devices allow investigation of the still-unresolved issues.
A pilot study comparing mouse and mouse-emulating interface devices for graphic input.
Kanny, E M; Anson, D K
1991-01-01
Adaptive interface devices make it possible for individuals with physical disabilities to use microcomputers and thus perform many tasks that they would otherwise be unable to accomplish. Special equipment is available that purports to allow functional access to the computer for users with disabilities. As technology moves from purely keyboard applications to include graphic input, it will be necessary for assistive interface devices to support graphics as well as text entry. Headpointing systems that emulate the mouse in combination with on-screen keyboards are of particular interest to persons with severe physical impairment such as high level quadriplegia. Two such systems currently on the market are the HeadMaster and the Free Wheel. The authors have conducted a pilot study comparing graphic input speed using the mouse and two headpointing interface systems on the Macintosh computer. The study used a single subject design with six able-bodied subjects, to establish a baseline for comparison with persons with severe disabilities. Results of these preliminary data indicated that the HeadMaster was nearly as effective as the mouse and that it was superior to the Free Wheel for graphics input. This pilot study, however, demonstrated several experimental design problems that need to be addressed to make the study more robust. It also demonstrated the need to include the evaluation of text input so that the effectiveness of the interface devices with text and graphic input could be compared.
Iseler, Jackeline; Fox, John; Wierenga, Kelly
2018-06-01
The 30-day readmission rate for patients with a left ventricular assist device implantation at a large, urban, Midwest hospital system (from October 2013 to September 2014) was estimated at 32.1%. Readmission rates were a concern at this facility. Review of the readmissions, change in practice, and home expectations of patients and families have identified an opportunity to improve the transitions of care for this left ventricular assist device (LVAD) program. Therefore, the purpose of this project was to evaluate the effectiveness and feasibility of a transitional care model (TCM) for care of patients with left ventricular devices. Ten patients were enrolled in the pilot that was implemented in June 2015. A transitional care nurse trained to support patients with ventricular assist devices was used to facilitate patient flow. The goal was to create an individualized plan for the development or improvement of self-management skills to decrease readmission rates. The transitional care nurse collaborated with the ventricular device team. The 30-day readmission rate during the pilot was 14.3% compared to the previous annual overall rate of 42.6%. Based on these results, further research is recommended into interventions consistent with the TCM to advance care coordination and to facilitate care transition in the this fragile patient population.
NASA Astrophysics Data System (ADS)
Smith, Roger J.
2008-10-01
A novel diagnostic technique for the remote and nonperturbative sensing of the local magnetic field in reactor relevant plasmas is presented. Pulsed polarimetry [Patent No. 12/150,169 (pending)] combines optical scattering with the Faraday effect. The polarimetric light detection and ranging (LIDAR)-like diagnostic has the potential to be a local Bpol diagnostic on ITER and can achieve spatial resolutions of millimeters on high energy density (HED) plasmas using existing lasers. The pulsed polarimetry method is based on nonlocal measurements and subtle effects are introduced that are not present in either cw polarimetry or Thomson scattering LIDAR. Important features include the capability of simultaneously measuring local Te, ne, and B∥ along the line of sight, a resiliency to refractive effects, a short measurement duration providing near instantaneous data in time, and location for real-time feedback and control of magnetohydrodynamic (MHD) instabilities and the realization of a widely applicable internal magnetic field diagnostic for the magnetic fusion energy program. The technique improves for higher neB∥ product and higher ne and is well suited for diagnosing the transient plasmas in the HED program. Larger devices such as ITER and DEMO are also better suited to the technique, allowing longer pulse lengths and thereby relaxing key technology constraints making pulsed polarimetry a valuable asset for next step devices. The pulsed polarimetry technique is clarified by way of illustration on the ITER tokamak and plasmas within the magnetized target fusion program within present technological means.
Ultra-high speed digital micro-mirror device based ptychographic iterative engine method
Sun, Aihui; He, Xiaoliang; Kong, Yan; Cui, Haoyang; Song, Xiaojun; Xue, Liang; Wang, Shouyu; Liu, Cheng
2017-01-01
To reduce the long data acquisition time of the common mechanical scanning based Ptychographic Iterative Engine (PIE) technique, the digital micro-mirror device (DMD) is used to form the fast scanning illumination on the sample. Since the transverse mechanical scanning in the common PIE is replaced by the on/off switching of the micro-mirrors, the data acquisition time can be reduced from more than 15 minutes to less than 20 seconds for recording 12 × 10 diffraction patterns to cover the same field of 147.08 mm2. Furthermore, since the precision of DMD fabricated with the optical lithography is always higher than 10 nm (1 μm for the mechanical translation stage), the time consuming position-error-correction procedure is not required in the iterative reconstruction. These two improvements fundamentally speed up both the data acquisition and the reconstruction procedures in PIE, and relax its requirements on the stability of the imaging system, therefore remarkably improve its applicability for many practices. It is demonstrated experimentally with both USAF resolution target and biological sample that, the spatial resolution of 5.52 μm and the field of view of 147.08 mm2 can be reached with the DMD based PIE method. In a word, by using the DMD to replace the translation stage, we can effectively overcome the main shortcomings of common PIE related to the mechanical scanning, while keeping its advantages on both the high resolution and large field of view. PMID:28717560
Two-Level Hierarchical FEM Method for Modeling Passive Microwave Devices
NASA Astrophysics Data System (ADS)
Polstyanko, Sergey V.; Lee, Jin-Fa
1998-03-01
In recent years multigrid methods have been proven to be very efficient for solving large systems of linear equations resulting from the discretization of positive definite differential equations by either the finite difference method or theh-version of the finite element method. In this paper an iterative method of the multiple level type is proposed for solving systems of algebraic equations which arise from thep-version of the finite element analysis applied to indefinite problems. A two-levelV-cycle algorithm has been implemented and studied with a Gauss-Seidel iterative scheme used as a smoother. The convergence of the method has been investigated, and numerical results for a number of numerical examples are presented.
Streaking into middle school science: The Dell Streak pilot project
NASA Astrophysics Data System (ADS)
Austin, Susan Eudy
A case study is conducted implementing the Dell Streak seven-inch android device into eighth grade science classes of one teacher in a rural middle school in the Piedmont region of North Carolina. The purpose of the study is to determine if the use of the Dell Streaks would increase student achievement on standardized subject testing, if the Streak could be used as an effective instructional tool, and if it could be considered an effective instructional resource for reviewing and preparing for the science assessments. A mixed method research design was used for the study to analyze both quantitative and qualitative results to determine if the Dell Streaks' utilization could achieve the following: 1. instructional strategies would change, 2. it would be an effective instructional tool, and 3. a comparison of the students' test scores and benchmark assessments' scores would provide statistically significant difference. Through the use of an ANOVA it was determined a statistically significant difference had occurred. A Post Hoc analysis was conducted to identify where the difference occurred. Finally a T-test determined was there was no statistically significance difference between the mean End-of-Grade tests and four quarterly benchmark scores of the control and the experimental groups. Qualitative research methods were used to gather results to determine if the Streaks were an effective instructional tool. Classroom observations identified that the teacher's teaching styles and new instructional strategies were implemented throughout the pilot project. Students had an opportunity to complete a questionnaire three times during the pilot project. Results revealed what the students liked about using the devices and the challenges they were facing. The teacher completed a reflective questionnaire throughout the pilot project and offered valuable reflections about the use of the devices in an educational setting. The reflection data supporting the case study was drawn from the teacher's statements regarding the change in instructional delivery as a respect of using the students' device. The results section of the study will elaborate upon these findings. The study recommendations on the use of the Dell Streak device will address whether further actions as the use of the Streak technology in the classroom and summary section.
Tuffaha, Haitham W; Reynolds, Heather; Gordon, Louisa G; Rickard, Claire M; Scuffham, Paul A
2014-12-01
Value of information analysis has been proposed as an alternative to the standard hypothesis testing approach, which is based on type I and type II errors, in determining sample sizes for randomized clinical trials. However, in addition to sample size calculation, value of information analysis can optimize other aspects of research design such as possible comparator arms and alternative follow-up times, by considering trial designs that maximize the expected net benefit of research, which is the difference between the expected cost of the trial and the expected value of additional information. To apply value of information methods to the results of a pilot study on catheter securement devices to determine the optimal design of a future larger clinical trial. An economic evaluation was performed using data from a multi-arm randomized controlled pilot study comparing the efficacy of four types of catheter securement devices: standard polyurethane, tissue adhesive, bordered polyurethane and sutureless securement device. Probabilistic Monte Carlo simulation was used to characterize uncertainty surrounding the study results and to calculate the expected value of additional information. To guide the optimal future trial design, the expected costs and benefits of the alternative trial designs were estimated and compared. Analysis of the value of further information indicated that a randomized controlled trial on catheter securement devices is potentially worthwhile. Among the possible designs for the future trial, a four-arm study with 220 patients/arm would provide the highest expected net benefit corresponding to 130% return-on-investment. The initially considered design of 388 patients/arm, based on hypothesis testing calculations, would provide lower net benefit with return-on-investment of 79%. Cost-effectiveness and value of information analyses were based on the data from a single pilot trial which might affect the accuracy of our uncertainty estimation. Another limitation was that different follow-up durations for the larger trial were not evaluated. The value of information approach allows efficient trial design by maximizing the expected net benefit of additional research. This approach should be considered early in the design of randomized clinical trials. © The Author(s) 2014.
Wang, Jingen; Zhou, Yongfei; Xia, Shuxia; Zhu, Zunwei; Jia, Linghua; Liu, Yong; Jiang, Min
2014-01-01
Background We evaluated the safety and efficacy of a novel disposable male circumcision (MC) device developed by Jiangxi-Yuansheng-Langhe Medical Instrument Co., Ltd. Material/Methods Adult male patients (n=120; mean age, 26.6 years) with redundant foreskin and/or phimosis were included in a randomized, multicenter pilot clinical trial from October 2011 to February 2012. Patients were divided into 2 groups and subjected to MC with a novel disposable device (Device Group) (n=60) or to conventional dissection technique (CDT) (Control Group) (n=60). Intraoperative bleeding, surgery duration, pain, healing, and satisfaction with penis appearance were assessed. Adverse events (AEs) were noted. Results Intraoperative bleeding volume [3.5±2.7 (15–35) ml vs. 13.1±6.1 (4–25) ml] and mean surgical time [7.6±4.5 (2–23) min vs. 23.6±4.4 (15–35) min] in the Device Group were significantly less than in the Control Group (P<0.01). No AEs were observed in either group. There were no significant differences in postoperative pain, healing, or satisfaction with penis appearance between groups (P>0.05). Conclusions This novel disposable circumcision device produced satisfactory preliminary adult MC results compared with CDT treatments. This device may be broadly used in men, such as those with phimosis, who are ineligible for CDT. PMID:24647226
Evaluation of three different devices to reduce stasis edema in poorly mobile nursing home patients.
Benigni, Jean-Patrick; Uhl, Jean-François; Balet, Florence; Filori, Pascal; Chahim, Maxime
2018-03-08
Prolonged immobility in the sitting position in the elderly is known to produce venous stasis with leg edema and possible skin changes. Compression stockings are often applied for this clinical problem. There are few experienced nursing staff available to supervise the difficult task of stocking application. The authors have researched other effective and simple devices that may be suitable alternatives. This article reports the results of three different devices to reduce leg edema, as measured by reduction in leg volume : an electro- stimulation device, an adjustable compression Velcro® wrap and a short stretch bandage, each tested over a two-hour period. In this randomized pilot study including 38 patients, the authors observed no difference in leg volume following electro-stimulation (Veinoplus®). They noted a significant reduction in leg volume following use of the other two devices, more with the adjustable Velcro® wrap compression (Circaid Juxtafit®) than with the short stretch bandage (Rosidal K®). Measurement of the interface pressures created by these two devices and also assessing the stiffness created by applying each device for two hours confirm that pressure is more important than stiffness in the reduction of edema in these particular patients. This pilot study is to be added to the results of previous published studies showing the efficacy in reducting leg edema of Velcro® adjustable compression wrap and its ease of use.
NASA Astrophysics Data System (ADS)
van Swaaij, G. A.; Bystrov, K.; Borodin, D.; Kirschner, A.; van der Vegt, L. B.; van Rooij, G. J.; De Temmerman, G.; Goedheer, W. J.
2012-09-01
For understanding carbon erosion and redeposition in nuclear fusion devices, it is important to understand the transport and chemical break-up of hydrocarbon molecules in edge plasmas, often diagnosed by emission of the CH A 2Δ-X 2Π Gerö band around 430 nm. The CH A-level can be excited either by electron-impact (EI) or by dissociative recombination (DR) of hydrocarbon ions. These processes were included in the 3D Monte Carlo impurity transport code ERO. A series of methane injection experiments was performed in the high-density, low-temperature linear plasma generator Pilot-PSI, and simulated emission intensity profiles were benchmarked against these experiments. It was confirmed that excitation by DR dominates at Te < 1.5 eV. The results indicate that the fraction of DR events that lead to a CH radical in the A-level and consequent photon emission is at least 10%. Additionally, quenching of the excited CH radicals by EI de-excitation was included in the modeling. This quenching is shown to be significant: depending on the electron density, it reduces the effective CH emission by a factor of 1.4 at ne = 1.3 × 1020 m-3, to 2.8 at ne = 9.3 × 1020 m-3. Its inclusion significantly improved agreement between experiment and modeling.
2011-01-01
Background Active travel such as walking and cycling has potential to increase physical activity levels in sedentary individuals. Motorised car travel is a sedentary behaviour that contributes to carbon emissions. There have been recent calls for technology that will improve our ability to measure these travel behaviours, and in particular evaluate modes and volumes of active versus sedentary travel. The purpose of this pilot study is to investigate the potential efficacy of a new electronic measurement device, a wearable digital camera called SenseCam, in travel research. Methods Participants (n = 20) were required to wear the SenseCam device for one full day of travel. The device automatically records approximately 3,600 time-stamped, first-person point-of-view images per day, without any action required by the wearer. Participants also completed a self-report travel diary over the same period for comparison, and were interviewed afterwards to assess user burden and experience. Results There were a total of 105 confirmed journeys in this pilot. The new SenseCam device recorded more journeys than the travel diary (99 vs. 94). Although the two measures demonstrated an acceptable correlation for journey duration (r = 0.92, p < 0.001) self-reported journey duration was over-reported (mean difference 154 s per journey; 95% CI = 89 to 218 s; 95% limits of agreement = 154 ± 598 s (-444 to 752 s)). The device also provided visual data that was used for directed interviews about sources of error. Conclusions Direct observation of travel behaviour from time-stamped images shows considerable potential in the field of travel research. Journey duration derived from direct observation of travel behaviour from time-stamped images appears to suggest over-reporting of self-reported journey duration. PMID:21599935
Kelly, Paul; Doherty, Aiden; Berry, Emma; Hodges, Steve; Batterham, Alan M; Foster, Charlie
2011-05-20
Active travel such as walking and cycling has potential to increase physical activity levels in sedentary individuals. Motorised car travel is a sedentary behaviour that contributes to carbon emissions. There have been recent calls for technology that will improve our ability to measure these travel behaviours, and in particular evaluate modes and volumes of active versus sedentary travel. The purpose of this pilot study is to investigate the potential efficacy of a new electronic measurement device, a wearable digital camera called SenseCam, in travel research. Participants (n = 20) were required to wear the SenseCam device for one full day of travel. The device automatically records approximately 3,600 time-stamped, first-person point-of-view images per day, without any action required by the wearer. Participants also completed a self-report travel diary over the same period for comparison, and were interviewed afterwards to assess user burden and experience. There were a total of 105 confirmed journeys in this pilot. The new SenseCam device recorded more journeys than the travel diary (99 vs. 94). Although the two measures demonstrated an acceptable correlation for journey duration (r = 0.92, p < 0.001) self-reported journey duration was over-reported (mean difference 154 s per journey; 95% CI = 89 to 218 s; 95% limits of agreement = 154 ± 598 s (-444 to 752 s)). The device also provided visual data that was used for directed interviews about sources of error. Direct observation of travel behaviour from time-stamped images shows considerable potential in the field of travel research. Journey duration derived from direct observation of travel behaviour from time-stamped images appears to suggest over-reporting of self-reported journey duration.
Pelletier, Alexandra; Sunthara, Gajen; Gujral, Nitin; Mittal, Vandna; Bourgeois, Fabienne C
2016-01-01
Background Hospitals today are introducing new mobile apps to improve patient care and workflow processes. Mobile device adoption by hospitals fits with present day technology behavior; however, requires a deeper look into hospital device policies and the impact on patients, staff, and technology development. Should hospitals spend thousands to millions of dollars to equip all personnel with a mobile device that is only used in a hospital environment? Allowing health care professionals to use personal mobile devices at work, known as bring-your-own-device (BYOD), has the potential to support both the hospital and its employees to deliver effective and efficient care. Objective The objectives of this research were to create a mobile app development guideline for a BYOD hospital environment, apply the guideline to the development of an in-house mobile app called TaskList, pilot the TaskList app within Boston Children’s Hospital (BCH), and refine the guideline based on the app pilot. TaskList is an Apple operating system (iOS)-based app designed for medical residents to monitor, create, capture, and share daily collaborative tasks associated with patients. Methods To create the BYOD guidelines, we developed TaskList that required the use of mobile devices among medical resident. The TaskList app was designed in four phases: (1) mobile app guideline development, (2) requirements gathering and developing of TaskList fitting the guideline, (3) deployment of TaskList using BYOD with end-users, and (4) refinement of the guideline based on the TaskList pilot. Phase 1 included understanding the existing hospital BYOD policies and conducting Web searches to find best practices in software development for a BYOD environment. Phase 1 also included gathering subject matter input from the Information Services Department (ISD) at BCH. Phase 2 involved the collaboration between the Innovation Acceleration Program at BCH, the ISD Department and the TaskList Clinical team in understanding what features should be built into the app. Phase 3 involved deployment of TaskList on a clinical floor at BCH. Lastly, Phase 4 gathered the lessons learned from the pilot to refine the guideline. Results Fourteen practical recommendations were identified to create the BCH Mobile Application Development Guideline to safeguard custom applications in hospital BYOD settings. The recommendations were grouped into four categories: (1) authentication and authorization, (2) data management, (3) safeguarding app environment, and (4) remote enforcement. Following the guideline, the TaskList app was developed and then was piloted with an inpatient ward team. Conclusions The Mobile Application Development guideline was created and used in the development of TaskList. The guideline is intended for use by developers when addressing integration with hospital information systems, deploying apps in BYOD health care settings, and meeting compliance standards, such as Health Insurance Portability and Accountability Act (HIPAA) regulations. PMID:27169345
Al Ayubi, Soleh U; Pelletier, Alexandra; Sunthara, Gajen; Gujral, Nitin; Mittal, Vandna; Bourgeois, Fabienne C
2016-05-11
Hospitals today are introducing new mobile apps to improve patient care and workflow processes. Mobile device adoption by hospitals fits with present day technology behavior; however, requires a deeper look into hospital device policies and the impact on patients, staff, and technology development. Should hospitals spend thousands to millions of dollars to equip all personnel with a mobile device that is only used in a hospital environment? Allowing health care professionals to use personal mobile devices at work, known as bring-your-own-device (BYOD), has the potential to support both the hospital and its employees to deliver effective and efficient care. The objectives of this research were to create a mobile app development guideline for a BYOD hospital environment, apply the guideline to the development of an in-house mobile app called TaskList, pilot the TaskList app within Boston Children's Hospital (BCH), and refine the guideline based on the app pilot. TaskList is an Apple operating system (iOS)-based app designed for medical residents to monitor, create, capture, and share daily collaborative tasks associated with patients. To create the BYOD guidelines, we developed TaskList that required the use of mobile devices among medical resident. The TaskList app was designed in four phases: (1) mobile app guideline development, (2) requirements gathering and developing of TaskList fitting the guideline, (3) deployment of TaskList using BYOD with end-users, and (4) refinement of the guideline based on the TaskList pilot. Phase 1 included understanding the existing hospital BYOD policies and conducting Web searches to find best practices in software development for a BYOD environment. Phase 1 also included gathering subject matter input from the Information Services Department (ISD) at BCH. Phase 2 involved the collaboration between the Innovation Acceleration Program at BCH, the ISD Department and the TaskList Clinical team in understanding what features should be built into the app. Phase 3 involved deployment of TaskList on a clinical floor at BCH. Lastly, Phase 4 gathered the lessons learned from the pilot to refine the guideline. Fourteen practical recommendations were identified to create the BCH Mobile Application Development Guideline to safeguard custom applications in hospital BYOD settings. The recommendations were grouped into four categories: (1) authentication and authorization, (2) data management, (3) safeguarding app environment, and (4) remote enforcement. Following the guideline, the TaskList app was developed and then was piloted with an inpatient ward team. The Mobile Application Development guideline was created and used in the development of TaskList. The guideline is intended for use by developers when addressing integration with hospital information systems, deploying apps in BYOD health care settings, and meeting compliance standards, such as Health Insurance Portability and Accountability Act (HIPAA) regulations.
Sputtering effects on mirrors made of different tungsten grades
NASA Astrophysics Data System (ADS)
Voitsenya, V. S.; Ogorodnikova, O. V.; Bardamid, A. F.; Bondarenko, V. N.; Konovalov, V. G.; Lytvyn, P. M.; Marot, L.; Ryzhkov, I. V.; Shtan', A. F.; Skoryk, O. O.; Solodovchenko, S. I.
2018-03-01
Because tungsten (W) is used in present fusion devices and it is a reference material for ITER divertor and possible plasma-facing material for DEMO, we strive to understand the response of different W grades to ion bombardment. In this study, we investigated the behavior of mirrors made of four polycrystalline W grades under long-term ion sputtering. Argon (Ar) and deuterium (D) ions extracted from a plasma were used to investigate the effect of projectile mass on surface modification. Depending on the ion fluence, the reflectance measured at normal incidence was very different for different W grades. The lowest degradation rate of the reflectance was measured for the mirror made of recrystallized W. The highest degradation rate was found for one of the ITER-grade W samples. Pre-irradiation of a mirror with 20-MeV W6+ ions, as simulation of neutron irradiation in ITER, had no noticeable influence on reflectance degradation under sputtering with either Ar or D ions.
Alfvén eigenmode evolution computed with the VENUS and KINX codes for the ITER baseline scenario
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaev, M. Yu., E-mail: isaev-my@nrcki.ru; Medvedev, S. Yu.; Cooper, W. A.
A new application of the VENUS code is described, which computes alpha particle orbits in the perturbed electromagnetic fields and its resonant interaction with the toroidal Alfvén eigenmodes (TAEs) for the ITER device. The ITER baseline scenario with Q = 10 and the plasma toroidal current of 15 MA is considered as the most important and relevant for the International Tokamak Physics Activity group on energetic particles (ITPA-EP). For this scenario, typical unstable TAE-modes with the toroidal index n = 20 have been predicted that are localized in the plasma core near the surface with safety factor q = 1.more » The spatial structure of ballooning and antiballooning modes has been computed with the ideal MHD code KINX. The linear growth rates and the saturation levels taking into account the damping effects and the different mode frequencies have been calculated with the VENUS code for both ballooning and antiballooning TAE-modes.« less
Analysis and Design of ITER 1 MV Core Snubber
NASA Astrophysics Data System (ADS)
Wang, Haitian; Li, Ge
2012-11-01
The core snubber, as a passive protection device, can suppress arc current and absorb stored energy in stray capacitance during the electrical breakdown in accelerating electrodes of ITER NBI. In order to design the core snubber of ITER, the control parameters of the arc peak current have been firstly analyzed by the Fink-Baker-Owren (FBO) method, which are used for designing the DIIID 100 kV snubber. The B-H curve can be derived from the measured voltage and current waveforms, and the hysteresis loss of the core snubber can be derived using the revised parallelogram method. The core snubber can be a simplified representation as an equivalent parallel resistance and inductance, which has been neglected by the FBO method. A simulation code including the parallel equivalent resistance and inductance has been set up. The simulation and experiments result in dramatically large arc shorting currents due to the parallel inductance effect. The case shows that the core snubber utilizing the FBO method gives more compact design.
Three dimensional iterative beam propagation method for optical waveguide devices
NASA Astrophysics Data System (ADS)
Ma, Changbao; Van Keuren, Edward
2006-10-01
The finite difference beam propagation method (FD-BPM) is an effective model for simulating a wide range of optical waveguide structures. The classical FD-BPMs are based on the Crank-Nicholson scheme, and in tridiagonal form can be solved using the Thomas method. We present a different type of algorithm for 3-D structures. In this algorithm, the wave equation is formulated into a large sparse matrix equation which can be solved using iterative methods. The simulation window shifting scheme and threshold technique introduced in our earlier work are utilized to overcome the convergence problem of iterative methods for large sparse matrix equation and wide-angle simulations. This method enables us to develop higher-order 3-D wide-angle (WA-) BPMs based on Pade approximant operators and the multistep method, which are commonly used in WA-BPMs for 2-D structures. Simulations using the new methods will be compared to the analytical results to assure its effectiveness and applicability.
Makerspaces: The Next Iteration for Educational Technology in K-12 Schools
ERIC Educational Resources Information Center
Strycker, Jesse
2015-01-01
With the continually growing number of computers and mobile devices available in K-12 schools, the need is dwindling for dedicated computer labs and media centers. Some schools are starting to repurpose those facilities into different kinds of exploratory learning environments known as "makerspaces". This article discusses this next…
ERIC Educational Resources Information Center
Sutton, Amy
2013-01-01
This article explores the possibility of using eReaders in the schools of the Houston Independent School District (HISD), specifically the Barnes and Noble Nook Pilot Project. HSID initially approved only an eReading device that was not wireless since it is very strict on the devices granted access to the wireless network. The biggest roadblock…
The Use of Personal Data Assistants in Early Childhood Assessment
ERIC Educational Resources Information Center
Ledoux, Michael W.; Yoder, Noreen N.; Hanes, Barbara
2010-01-01
Four early childhood education teachers, two veteran and two newer teachers, were asked to pilot the use of handheld Personal Data Assistants loaded with Childchart assessment software. The participants were observed in their use of the electronic devices for monitoring student performance and interviewed regarding the use of the devices and their…
Haslbeck, Andreas; Zhang, Bo
2017-09-01
The aim of this study was to analyze pilots' visual scanning in a manual approach and landing scenario. Manual flying skills suffer from increasing use of automation. In addition, predominantly long-haul pilots with only a few opportunities to practice these skills experience this decline. Airline pilots representing different levels of practice (short-haul vs. long-haul) had to perform a manual raw data precision approach while their visual scanning was recorded by an eye-tracking device. The analysis of gaze patterns, which are based on predominant saccades, revealed one main group of saccades among long-haul pilots. In contrast, short-haul pilots showed more balanced scanning using two different groups of saccades. Short-haul pilots generally demonstrated better manual flight performance and within this group, one type of scan pattern was found to facilitate the manual landing task more. Long-haul pilots tend to utilize visual scanning behaviors that are inappropriate for the manual ILS landing task. This lack of skills needs to be addressed by providing specific training and more practice. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
LeMaster, W. Dean; Gray, Thomas H.
The purpose of this study was to develop a screening procedure for undergraduate pilot training (UPT). This procedure was based upon the use of ground-based instrument trainers in which UPT candidates, naive to flying, were evaluated in their performance of job sample tasks; i.e., basic instrument flying. Training and testing sessions were…
ERIC Educational Resources Information Center
Sng, Cheong Ying; Carter, Mark; Stephenson, Jennifer
2017-01-01
Scripts in written or auditory form have been used to teach conversational skills to individuals with autism spectrum disorder (ASD), but with the proliferation of handheld tablet devices the scope to combine these 2 formats has broadened. The aim of this pilot study was to investigate if a script-based intervention, presented on an iPad…
Theory underlying the peripheral vision horizon device
NASA Technical Reports Server (NTRS)
Money, K. E.
1984-01-01
Peripheral Vision Horizon Device (PVHD) theory states that the likelihood of pilot disorientation in flight is reduced by providing an artificial horizon that provides orientation information to peripheral vision. In considering the validity of the theory, three areas are explored: the use of an artificial horizon device over some other flight instrument; the use of peripheral vision over foveal vision; and the evidence that peripheral vision is well suited to the processing of orientation information.
Optical Docking Aid Containing Fresnel Lenses
NASA Technical Reports Server (NTRS)
Pierce, Cole J.
1995-01-01
Proposed device provides self-contained visual cues to aid in docking. Similar to devices used to guide pilots in landing on aircraft carriers. Positions and directions of beams of light give observer visual cues of position relative to docking target point. Optical assemblies generate directed, diverging beams of light that, together, mark approach path to docking point. Conceived for use in docking spacecraft at Space Station Freedom, device adapted to numerous industrial docking and alignment applications.
NASA Astrophysics Data System (ADS)
Brezinsek, S.; Coenen, J. W.; Schwarz-Selinger, T.; Schmid, K.; Kirschner, A.; Hakola, A.; Tabares, F. L.; van der Meiden, H. J.; Mayoral, M.-L.; Reinhart, M.; Tsitrone, E.; Ahlgren, T.; Aints, M.; Airila, M.; Almaviva, S.; Alves, E.; Angot, T.; Anita, V.; Arredondo Parra, R.; Aumayr, F.; Balden, M.; Bauer, J.; Ben Yaala, M.; Berger, B. M.; Bisson, R.; Björkas, C.; Bogdanovic Radovic, I.; Borodin, D.; Bucalossi, J.; Butikova, J.; Butoi, B.; Čadež, I.; Caniello, R.; Caneve, L.; Cartry, G.; Catarino, N.; Čekada, M.; Ciraolo, G.; Ciupinski, L.; Colao, F.; Corre, Y.; Costin, C.; Craciunescu, T.; Cremona, A.; De Angeli, M.; de Castro, A.; Dejarnac, R.; Dellasega, D.; Dinca, P.; Dittmar, T.; Dobrea, C.; Hansen, P.; Drenik, A.; Eich, T.; Elgeti, S.; Falie, D.; Fedorczak, N.; Ferro, Y.; Fornal, T.; Fortuna-Zalesna, E.; Gao, L.; Gasior, P.; Gherendi, M.; Ghezzi, F.; Gosar, Ž.; Greuner, H.; Grigore, E.; Grisolia, C.; Groth, M.; Gruca, M.; Grzonka, J.; Gunn, J. P.; Hassouni, K.; Heinola, K.; Höschen, T.; Huber, S.; Jacob, W.; Jepu, I.; Jiang, X.; Jogi, I.; Kaiser, A.; Karhunen, J.; Kelemen, M.; Köppen, M.; Koslowski, H. R.; Kreter, A.; Kubkowska, M.; Laan, M.; Laguardia, L.; Lahtinen, A.; Lasa, A.; Lazic, V.; Lemahieu, N.; Likonen, J.; Linke, J.; Litnovsky, A.; Linsmeier, Ch.; Loewenhoff, T.; Lungu, C.; Lungu, M.; Maddaluno, G.; Maier, H.; Makkonen, T.; Manhard, A.; Marandet, Y.; Markelj, S.; Marot, L.; Martin, C.; Martin-Rojo, A. B.; Martynova, Y.; Mateus, R.; Matveev, D.; Mayer, M.; Meisl, G.; Mellet, N.; Michau, A.; Miettunen, J.; Möller, S.; Morgan, T. W.; Mougenot, J.; Mozetič, M.; Nemanič, V.; Neu, R.; Nordlund, K.; Oberkofler, M.; Oyarzabal, E.; Panjan, M.; Pardanaud, C.; Paris, P.; Passoni, M.; Pegourie, B.; Pelicon, P.; Petersson, P.; Piip, K.; Pintsuk, G.; Pompilian, G. O.; Popa, G.; Porosnicu, C.; Primc, G.; Probst, M.; Räisänen, J.; Rasinski, M.; Ratynskaia, S.; Reiser, D.; Ricci, D.; Richou, M.; Riesch, J.; Riva, G.; Rosinski, M.; Roubin, P.; Rubel, M.; Ruset, C.; Safi, E.; Sergienko, G.; Siketic, Z.; Sima, A.; Spilker, B.; Stadlmayr, R.; Steudel, I.; Ström, P.; Tadic, T.; Tafalla, D.; Tale, I.; Terentyev, D.; Terra, A.; Tiron, V.; Tiseanu, I.; Tolias, P.; Tskhakaya, D.; Uccello, A.; Unterberg, B.; Uytdenhoven, I.; Vassallo, E.; Vavpetič, P.; Veis, P.; Velicu, I. L.; Vernimmen, J. W. M.; Voitkans, A.; von Toussaint, U.; Weckmann, A.; Wirtz, M.; Založnik, A.; Zaplotnik, R.; PFC contributors, WP
2017-11-01
The provision of a particle and power exhaust solution which is compatible with first-wall components and edge-plasma conditions is a key area of present-day fusion research and mandatory for a successful operation of ITER and DEMO. The work package plasma-facing components (WP PFC) within the European fusion programme complements with laboratory experiments, i.e. in linear plasma devices, electron and ion beam loading facilities, the studies performed in toroidally confined magnetic devices, such as JET, ASDEX Upgrade, WEST etc. The connection of both groups is done via common physics and engineering studies, including the qualification and specification of plasma-facing components, and by modelling codes that simulate edge-plasma conditions and the plasma-material interaction as well as the study of fundamental processes. WP PFC addresses these critical points in order to ensure reliable and efficient use of conventional, solid PFCs in ITER (Be and W) and DEMO (W and steel) with respect to heat-load capabilities (transient and steady-state heat and particle loads), lifetime estimates (erosion, material mixing and surface morphology), and safety aspects (fuel retention, fuel removal, material migration and dust formation) particularly for quasi-steady-state conditions. Alternative scenarios and concepts (liquid Sn or Li as PFCs) for DEMO are developed and tested in the event that the conventional solution turns out to not be functional. Here, we present an overview of the activities with an emphasis on a few key results: (i) the observed synergistic effects in particle and heat loading of ITER-grade W with the available set of exposition devices on material properties such as roughness, ductility and microstructure; (ii) the progress in understanding of fuel retention, diffusion and outgassing in different W-based materials, including the impact of damage and impurities like N; and (iii), the preferential sputtering of Fe in EUROFER steel providing an in situ W surface and a potential first-wall solution for DEMO.
Brezinsek, S.; Coenen, J. W.; Schwarz-Selinger, T.; ...
2017-06-14
The provision of a particle and power exhaust solution which is compatible with first-wall components and edge-plasma conditions is a key area of present-day fusion research and mandatory for a successful operation of ITER and DEMO. The work package plasma-facing components (WP PFC) within the European fusion programme complements with laboratory experiments, i.e. in linear plasma devices, electron and ion beam loading facilities, the studies performed in toroidally confined magnetic devices, such as JET, ASDEX Upgrade, WEST etc. The connection of both groups is done via common physics and engineering studies, including the qualification and specification of plasma-facing components, andmore » by modelling codes that simulate edge-plasma conditions and the plasma–material interaction as well as the study of fundamental processes. WP PFC addresses these critical points in order to ensure reliable and efficient use of conventional, solid PFCs in ITER (Be and W) and DEMO (W and steel) with respect to heat-load capabilities (transient and steady-state heat and particle loads), lifetime estimates (erosion, material mixing and surface morphology), and safety aspects (fuel retention, fuel removal, material migration and dust formation) particularly for quasi-steady-state conditions. Alternative scenarios and concepts (liquid Sn or Li as PFCs) for DEMO are developed and tested in the event that the conventional solution turns out to not be functional. Here, we present an overview of the activities with an emphasis on a few key results: (i) the observed synergistic effects in particle and heat loading of ITER-grade W with the available set of exposition devices on material properties such as roughness, ductility and microstructure; (ii) the progress in understanding of fuel retention, diffusion and outgassing in different W-based materials, including the impact of damage and impurities like N; and (iii), the preferential sputtering of Fe in EUROFER steel providing an in situ W surface and a potential first-wall solution for DEMO.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brezinsek, S.; Coenen, J. W.; Schwarz-Selinger, T.
The provision of a particle and power exhaust solution which is compatible with first-wall components and edge-plasma conditions is a key area of present-day fusion research and mandatory for a successful operation of ITER and DEMO. The work package plasma-facing components (WP PFC) within the European fusion programme complements with laboratory experiments, i.e. in linear plasma devices, electron and ion beam loading facilities, the studies performed in toroidally confined magnetic devices, such as JET, ASDEX Upgrade, WEST etc. The connection of both groups is done via common physics and engineering studies, including the qualification and specification of plasma-facing components, andmore » by modelling codes that simulate edge-plasma conditions and the plasma–material interaction as well as the study of fundamental processes. WP PFC addresses these critical points in order to ensure reliable and efficient use of conventional, solid PFCs in ITER (Be and W) and DEMO (W and steel) with respect to heat-load capabilities (transient and steady-state heat and particle loads), lifetime estimates (erosion, material mixing and surface morphology), and safety aspects (fuel retention, fuel removal, material migration and dust formation) particularly for quasi-steady-state conditions. Alternative scenarios and concepts (liquid Sn or Li as PFCs) for DEMO are developed and tested in the event that the conventional solution turns out to not be functional. Here, we present an overview of the activities with an emphasis on a few key results: (i) the observed synergistic effects in particle and heat loading of ITER-grade W with the available set of exposition devices on material properties such as roughness, ductility and microstructure; (ii) the progress in understanding of fuel retention, diffusion and outgassing in different W-based materials, including the impact of damage and impurities like N; and (iii), the preferential sputtering of Fe in EUROFER steel providing an in situ W surface and a potential first-wall solution for DEMO.« less
In vivo study of magnesium plate and screw degradation and bone fracture healing.
Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Myers, Nicole; Costello, Bernard J; Chou, Da-Tren; Pal, Siladitya; Maiti, Spandan; Kumta, Prashant N; Sfeir, Charles
2015-05-01
Each year, millions of Americans suffer bone fractures, often requiring internal fixation. Current devices, like plates and screws, are made with permanent metals or resorbable polymers. Permanent metals provide strength and biocompatibility, but cause long-term complications and may require removal. Resorbable polymers reduce long-term complications, but are unsuitable for many load-bearing applications. To mitigate complications, degradable magnesium (Mg) alloys are being developed for craniofacial and orthopedic applications. Their combination of strength and degradation make them ideal for bone fixation. Previously, we conducted a pilot study comparing Mg and titanium devices with a rabbit ulna fracture model. We observed Mg device degradation, with uninhibited healing. Interestingly, we observed bone formation around degrading Mg, but not titanium, devices. These results highlighted the potential for these fixation devices. To better assess their efficacy, we conducted a more thorough study assessing 99.9% Mg devices in a similar rabbit ulna fracture model. Device degradation, fracture healing, and bone formation were evaluated using microcomputed tomography, histology and biomechanical tests. We observed device degradation throughout, and calculated a corrosion rate of 0.40±0.04mm/year after 8 weeks. In addition, we observed fracture healing by 8 weeks, and maturation after 16 weeks. In accordance with our pilot study, we observed bone formation surrounding Mg devices, with complete overgrowth by 16 weeks. Bend tests revealed no difference in flexural load of healed ulnae with Mg devices compared to intact ulnae. These data suggest that Mg devices provide stabilization to facilitate healing, while degrading and stimulating new bone formation. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Odon device for instrumental vaginal deliveries: results of a medical device pilot clinical study.
Schvartzman, Javier A; Krupitzki, Hugo; Merialdi, Mario; Betrán, Ana Pilar; Requejo, Jennifer; Nguyen, My Huong; Vayena, Effy; Fiorillo, Angel E; Gadow, Enrique C; Vizcaino, Francisco M; von Petery, Felicitas; Marroquin, Victoria; Cafferata, María Luisa; Mazzoni, Agustina; Vannevel, Valerie; Pattinson, Robert C; Gülmezoglu, A Metin; Althabe, Fernando; Bonet, Mercedes
2018-03-12
A prolonged and complicated second stage of labour is associated with serious perinatal complications. The Odon device is an innovation intended to perform instrumental vaginal delivery presently under development. We present an evaluation of the feasibility and safety of delivery with early prototypes of this device from an early terminated clinical study. Hospital-based, multi-phased, open-label, pilot clinical study with no control group in tertiary hospitals in Argentina and South Africa. Multiparous and nulliparous women, with uncomplicated singleton pregnancies, were enrolled during the third trimester of pregnancy. Delivery with Odon device was attempted under non-emergency conditions during the second stage of labour. The feasibility outcome was delivery with the Odon device defined as successful expulsion of the fetal head after one-time application of the device. Of the 49 women enrolled, the Odon device was inserted successfully in 46 (93%), and successful Odon device delivery as defined above was achieved in 35 (71%) women. Vaginal, first and second degree perineal tears occurred in 29 (59%) women. Four women had cervical tears. No third or fourth degree perineal tears were observed. All neonates were born alive and vigorous. No adverse maternal or infant outcomes were observed at 6-weeks follow-up for all dyads, and at 1 year for the first 30 dyads. Delivery using the Odon device is feasible. Observed genital tears could be due to the device or the process of delivery and assessment bias. Evaluating the effectiveness and safety of the further developed prototype of the BD Odon Device™ will require a randomized-controlled trial. ANZCTR ACTRN12613000141741 Registered 06 February 2013. Retrospectively registered.
Topology-optimized metasurfaces: impact of initial geometric layout.
Yang, Jianji; Fan, Jonathan A
2017-08-15
Topology optimization is a powerful iterative inverse design technique in metasurface engineering and can transform an initial layout into a high-performance device. With this method, devices are optimized within a local design phase space, making the identification of suitable initial geometries essential. In this Letter, we examine the impact of initial geometric layout on the performance of large-angle (75 deg) topology-optimized metagrating deflectors. We find that when conventional metasurface designs based on dielectric nanoposts are used as initial layouts for topology optimization, the final devices have efficiencies around 65%. In contrast, when random initial layouts are used, the final devices have ultra-high efficiencies that can reach 94%. Our numerical experiments suggest that device topologies based on conventional metasurface designs may not be suitable to produce ultra-high-efficiency, large-angle metasurfaces. Rather, initial geometric layouts with non-trivial topologies and shapes are required.
NASA Technical Reports Server (NTRS)
Miller, W. S.
1974-01-01
The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.
Prospects for Advanced Tokamak Operation of ITER
NASA Astrophysics Data System (ADS)
Neilson, George H.
1996-11-01
Previous studies have identified steady-state (or "advanced") modes for ITER, based on reverse-shear profiles and significant bootstrap current. A typical example has 12 MA of plasma current, 1,500 MW of fusion power, and 100 MW of heating and current-drive power. The implementation of these and other steady-state operating scenarios in the ITER device is examined in order to identify key design modifications that can enhance the prospects for successfully achieving advanced tokamak operating modes in ITER compatible with a single null divertor design. In particular, we examine plasma configurations that can be achieved by the ITER poloidal field system with either a monolithic central solenoid (as in the ITER Interim Design), or an alternate "hybrid" central solenoid design which provides for greater flexibility in the plasma shape. The increased control capability and expanded operating space provided by the hybrid central solenoid allows operation at high triangularity (beneficial for improving divertor performance through control of edge-localized modes and for increasing beta limits), and will make it much easier for ITER operators to establish an optimum startup trajectory leading to a high-performance, steady-state scenario. Vertical position control is examined because plasmas made accessible by the hybrid central solenoid can be more elongated and/or less well coupled to the conducting structure. Control of vertical-displacements using the external PF coils remains feasible over much of the expanded operating space. Further work is required to define the full spectrum of axisymmetric plasma disturbances requiring active control In addition to active axisymmetric control, advanced tokamak modes in ITER may require active control of kink modes on the resistive time scale of the conducting structure. This might be accomplished in ITER through the use of active control coils external to the vacuum vessel which are actuated by magnetic sensors near the first wall. The enhanced shaping and positioning flexibility provides a range of options for reducing the ripple-induced losses of fast alpha particles--a major limitation on ITER steady-state modes. An alternate approach that we are pursuing in parallel is the inclusion of ferromagnetic inserts to reduce the toroidal field ripple within the plasma chamber. The inclusion of modest design changes such as the hybrid central solenoid, active control coils for kink modes, and ferromagnetic inserts for TF ripple reduction show can greatly increase the flexibility to accommodate advance tokamak operation in ITER. Increased flexibility is important because the optimum operating scenario for ITER cannot be predicted with certainty. While low-inductance, reverse shear modes appear attractive for steady-state operation, high-inductance, high-beta modes are also viable candidates, and it is important that ITER have the flexibility to explore both these, and other, operating regimes.
Status of the ITER Electron Cyclotron Heating and Current Drive System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Darbos, Caroline; Albajar, Ferran; Bonicelli, Tullio
2015-10-07
We present that the electron cyclotron (EC) heating and current drive (H&CD) system developed for the ITER is made of 12 sets of high-voltage power supplies feeding 24 gyrotrons connected through 24 transmission lines (TL), to five launchers, four located in upper ports and one at the equatorial level. Nearly all procurements are in-kind, following general ITER philosophy, and will come from Europe, India, Japan, Russia and the USA. The full system is designed to couple to the plasma 20 MW among the 24 MW generated power, at the frequency of 170 GHz, for various physics applications such as plasmamore » start-up, central H&CD and magnetohydrodynamic (MHD) activity control. The design takes present day technology and extends toward high-power continuous operation, which represents a large step forward as compared to the present state of the art. The ITER EC system will be a stepping stone to future EC systems for DEMO and beyond.The development of the EC system is facing significant challenges, which includes not only an advanced microwave system but also compliance with stringent requirements associated with nuclear safety as ITER became the first fusion device licensed as basic nuclear installations as of 9 November 2012. Finally, since the conceptual design of the EC system was established in 2007, the EC system has progressed to a preliminary design stage in 2012 and is now moving forward toward a final design.« less
Time-dependent modeling of dust injection in semi-detached ITER divertor plasma
NASA Astrophysics Data System (ADS)
Smirnov, Roman; Krasheninnikov, Sergei
2017-10-01
At present, it is generally understood that dust related issues will play important role in operation of the next step fusion devices, i.e. ITER, and in the development of future fusion reactors. Recent progress in research on dust in magnetic fusion devises has outlined several topics of particular concern: a) degradation of fusion plasma performance; b) impairment of in-vessel diagnostic instruments; and c) safety issues related to dust reactivity and tritium retention. In addition, observed dust events in fusion edge plasmas are highly irregular and require consideration of temporal evolution of both the dust and the fusion plasma. In order to address the dust-related fusion performance issues, we have coupled the dust transport code DUSTT and the edge plasma transport code UEDGE in time-dependent manner, allowing modeling of transient dust-induced phenomena in fusion edge plasmas. Using the coupled codes we simulate burst-like injection of tungsten dust into ITER divertor plasma in semi-detached regime, which is considered as preferable ITER divertor operational mode based on the plasma and heat load control restrictions. Analysis of transport of the dust and the dust-produced impurities, and of dynamics of the ITER divertor and edge plasma in response to the dust injection will be presented. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences, under Award Number DE-FG02-06ER54852.
Bullinger, Monika; Quitmann, Julia; Silva, Neuza; Rohenkohl, Anja; Chaplin, John E; DeBusk, Kendra; Mimoun, Emmanuelle; Feigerlova, Eva; Herdman, Michael; Sanz, Dolores; Wollmann, Hartmut; Pleil, Andreas; Power, Michael
2014-01-01
Testing cross-cultural equivalence of patient-reported outcomes requires sufficiently large samples per country, which is difficult to achieve in rare endocrine paediatric conditions. We describe a novel approach to cross-cultural testing of the Quality of Life in Short Stature Youth (QoLISSY) questionnaire in five countries by sequentially taking one country out (TOCO) from the total sample and iteratively comparing the resulting psychometric performance. Development of the QoLISSY proceeded from focus group discussions through pilot testing to field testing in 268 short-statured patients and their parents. To explore cross-cultural equivalence, the iterative TOCO technique was used to examine and compare the validity, reliability, and convergence of patient and parent responses on QoLISSY in the field test dataset, and to predict QoLISSY scores from clinical, socio-demographic and psychosocial variables. Validity and reliability indicators were satisfactory for each sample after iteratively omitting one country. Comparisons with the total sample revealed cross-cultural equivalence in internal consistency and construct validity for patients and parents, high inter-rater agreement and a substantial proportion of QoLISSY variance explained by predictors. The TOCO technique is a powerful method to overcome problems of country-specific testing of patient-reported outcome instruments. It provides an empirical support to QoLISSY's cross-cultural equivalence and is recommended for future research.
Implementing partnership-driven clinical federated electronic health record data sharing networks.
Stephens, Kari A; Anderson, Nicholas; Lin, Ching-Ping; Estiri, Hossein
2016-09-01
Building federated data sharing architectures requires supporting a range of data owners, effective and validated semantic alignment between data resources, and consistent focus on end-users. Establishing these resources requires development methodologies that support internal validation of data extraction and translation processes, sustaining meaningful partnerships, and delivering clear and measurable system utility. We describe findings from two federated data sharing case examples that detail critical factors, shared outcomes, and production environment results. Two federated data sharing pilot architectures developed to support network-based research associated with the University of Washington's Institute of Translational Health Sciences provided the basis for the findings. A spiral model for implementation and evaluation was used to structure iterations of development and support knowledge share between the two network development teams, which cross collaborated to support and manage common stages. We found that using a spiral model of software development and multiple cycles of iteration was effective in achieving early network design goals. Both networks required time and resource intensive efforts to establish a trusted environment to create the data sharing architectures. Both networks were challenged by the need for adaptive use cases to define and test utility. An iterative cyclical model of development provided a process for developing trust with data partners and refining the design, and supported measureable success in the development of new federated data sharing architectures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Tritium proof-of-principle pellet injector: Phase 2
NASA Astrophysics Data System (ADS)
Fisher, P. W.; Gouge, M. J.
1995-03-01
As part of the International Thermonuclear Engineering Reactor (ITER) plasma fueling development program, Oak Ridge National Laboratory (ORNL) has fabricated a pellet injection system to test the mechanical and thermal properties of extruded tritium. This repeating, single-stage, pneumatic injector, called the Tritium-Proof-of-Principle Phase-2 (TPOP-2) Pellet Injector, has a piston-driven mechanical extruder and is designed to extrude hydrogenic pellets sized for the ITER device. The TPOP-II program has the following development goals: evaluate the feasibility of extruding tritium and DT mixtures for use in future pellet injection systems; determine the mechanical and thermal properties of tritium and DT extrusions; integrate, test and evaluate the extruder in a repeating, single-stage light gas gun sized for the ITER application (pellet diameter approximately 7-8 mm); evaluate options for recycling propellant and extruder exhaust gas; evaluate operability and reliability of ITER prototypical fueling systems in an environment of significant tritium inventory requiring secondary and room containment systems. In initial tests with deuterium feed at ORNL, up to thirteen pellets have been extruded at rates up to 1 Hz and accelerated to speeds of order 1.0-1.1 km/s using hydrogen propellant gas at a supply pressure of 65 bar. The pellets are typically 7.4 mm in diameter and up to 11 mm in length and are the largest cryogenic pellets produced by the fusion program to date. These pellets represent about a 11% density perturbation to ITER. Hydrogenic pellets will be used in ITER to sustain the fusion power in the plasma core and may be crucial in reducing first wall tritium inventories by a process called isotopic fueling where tritium-rich pellets fuel the burning plasma core and deuterium gas fuels the edge.
Burning plasma regime for Fussion-Fission Research Facility
NASA Astrophysics Data System (ADS)
Zakharov, Leonid E.
2010-11-01
The basic aspects of burning plasma regimes of Fusion-Fission Research Facility (FFRF, R/a=4/1 m/m, Ipl=5 MA, Btor=4-6 T, P^DT=50-100 MW, P^fission=80-4000 MW, 1 m thick blanket), which is suggested as the next step device for Chinese fusion program, are presented. The mission of FFRF is to advance magnetic fusion to the level of a stationary neutron source and to create a technical, scientific, and technology basis for the utilization of high-energy fusion neutrons for the needs of nuclear energy and technology. FFRF will rely as much as possible on ITER design. Thus, the magnetic system, especially TFC, will take advantage of ITER experience. TFC will use the same superconductor as ITER. The plasma regimes will represent an extension of the stationary plasma regimes on HT-7 and EAST tokamaks at ASIPP. Both inductive discharges and stationary non-inductive Lower Hybrid Current Drive (LHCD) will be possible. FFRF strongly relies on new, Lithium Wall Fusion (LiWF) plasma regimes, the development of which will be done on NSTX, HT-7, EAST in parallel with the design work. This regime will eliminate a number of uncertainties, still remaining unresolved in the ITER project. Well controlled, hours long inductive current drive operation at P^DT=50-100 MW is predicted.
In-Vessel Tritium Retention and Removal in ITER-FEAT
NASA Astrophysics Data System (ADS)
Federici, G.; Brooks, J. N.; Iseli, M.; Wu, C. H.
Erosion of the divertor and first-wall plasma-facing components, tritium uptake in the re-deposited films, and direct implantation in the armour material surfaces surrounding the plasma, represent crucial physical issues that affect the design of future fusion devices. In this paper we present the derivation, and discuss the results, of current predictions of tritium inventory in ITER-FEAT due to co-deposition and implantation and their attendant uncertainties. The current armour materials proposed for ITER-FEAT are beryllium on the first-wall, carbon-fibre-composites on the divertor plate near the separatrix strike points, to withstand the high thermal loads expected during off-normal events, e.g., disruptions, and tungsten elsewhere in the divertor. Tritium co-deposition with chemically eroded carbon in the divertor, and possibly with some Be eroded from the first-wall, is expected to represent the dominant mechanism of in-vessel tritium retention in ITER-FEAT. This demands efficient in-situ methods of mitigation and retrieval to avoid frequent outages due to the reaching of precautionary operating limits set by safety considerations (e.g., ˜350 g of in-vessel co-deposited tritium) and for fuel economy reasons. Priority areas where further R&D work is required to narrow the remaining uncertainties are also briefly discussed.
Some not such wonderful magnetic fusion facts; and their solution
NASA Astrophysics Data System (ADS)
Manheimer, Wallace
2017-10-01
The first not such wonderful fusion fact (NSWFF) is that if ITER is successful, it is nowhere near ready to develop into a DEMO. The design Q=10, along with electricity generating efficiency of 1/3 prevents this. Making it smaller and cheaper, increasing the gain by 3 or 4, and the wall loading by an order of magnitude is not a minor detail, it is not at all clear the success with ITER will lead to a similar, pure fusion DEMO. The second NSWFF is that tokamaks are unlikely to improve to the point where they can be effective fusion reactors because their performance is limited by conservative design rules. The third NSWFF is that developing large fusion devices like ITER takes an enormous amount of time and dollars, there are no second chances. The fourth NSWFF is that it is unlikely that alternative confinement configurations will succeed either, at least in this century; they are simply too far behind. There is only a single solution for fusion to become a sustainable, carbon free power source by midcentury or shortly thereafter. This is to develop ITER (assuming it is successful) into a fusion breeder. This work was not supported by any organization, private or public.
Measured vs. Predicted Pedestal Pressure During RMP ELM Control in DIII-D
NASA Astrophysics Data System (ADS)
Zywicki, Bailey; Fenstermacher, Max; Groebner, Richard; Meneghini, Orso
2017-10-01
From database analysis of DIII-D plasmas with Resonant Magnetic Perturbations (RMPs) for ELM control, we will compare the experimental pedestal pressure (p_ped) to EPED code predictions and present the dependence of any p_ped differences from EPED on RMP parameters not included in the EPED model e.g. RMP field strength, toroidal and poloidal spectrum etc. The EPED code, based on Peeling-Ballooning and Kinetic Ballooning instability constraints, will also be used by ITER to predict the H-mode p_ped without RMPs. ITER plans to use RMPs as an effective ELM control method. The need to control ELMs in ITER is of the utmost priority, as it directly correlates to the lifetime of the plasma facing components. An accurate means of determining the impact of RMP ELM control on the p_ped is needed, because the device fusion power is strongly dependent on p_ped. With this new collection of data, we aim to provide guidance to predictions of the ITER pedestal during RMP ELM control that can be incorporated in a future predictive code. Work supported in part by US DoE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698, and DE-AC52-07NA27344.
1973-03-19
S73-20276 (1 March 1973) --- Astronaut Paul J. Weitz, pilot of the first manned Skylab mission, lies in the lower body negative pressure device during Skylab training at Johnson Space Center. Operating the controls in the background is scientist-astronaut Joseph P. Kerwin, science pilot of the mission. They are in the work and experiments area of the crew quarters of the Skylab Orbital Workshop (OWS) trainer at JSC. Photo credit: NASA
Department of Defense Mobile Device Strategy. Version 2.0
2012-05-01
pilots and initiatives across DoD under common objectives, ensuring that the war:fighter benefits from such activities and aligns with efforts...regularly travel from place to place; and a growing number of teleworkers are beginning to operate from locations other than their primary offices...workforce with the benefits of mobile technology. Although achieving pockets of success, this unconstrained piloting has also resulted in the lack of
Tools of the Trade: How Mobile Learning Devices Are Changing the Face of Higher Education
ERIC Educational Resources Information Center
Wong, Wylie
2012-01-01
Students and teachers are increasingly embracing tablets and e-book readers in their personal lives, but do these devices have a place on community college campuses? Several institutions are exploring answers to that very question by piloting mobile technologies inside and outside college classrooms. Scottsdale Community College (SCC) in Arizona,…
ERIC Educational Resources Information Center
Hostetler, Jerry C.; Englert, Duwayne C.
1987-01-01
Presents description of an interface device which ties in microcomputers and slide/tape presentations for computer assisted instruction. Highlights include the use of this technology in an introductory undergraduate zoology course; a discussion of authoring languages with emphasis on SuperPILOT; and hardware and software design for the interface.…
ERIC Educational Resources Information Center
Land, Susan M.; Zimmerman, Heather Toomey
2015-01-01
This design-based research project examines three iterations of Tree Investigators, a learning environment designed to support science learning outdoors at an arboretum and nature center using mobile devices (iPads). Researchers coded videorecords and artifacts created by children and parents (n = 53) to understand how both social and…
1988-04-01
devices of the language. When you think of a television show, a mental picture quickly flashes in your mind of the actor or actress who represents that...iteratively determine and validate what data the user needs displayed, how should will look ( i.e. color vs black and while and resolution) to the user and
Analysis Tools for CFD Multigrid Solvers
NASA Technical Reports Server (NTRS)
Mineck, Raymond E.; Thomas, James L.; Diskin, Boris
2004-01-01
Analysis tools are needed to guide the development and evaluate the performance of multigrid solvers for the fluid flow equations. Classical analysis tools, such as local mode analysis, often fail to accurately predict performance. Two-grid analysis tools, herein referred to as Idealized Coarse Grid and Idealized Relaxation iterations, have been developed and evaluated within a pilot multigrid solver. These new tools are applicable to general systems of equations and/or discretizations and point to problem areas within an existing multigrid solver. Idealized Relaxation and Idealized Coarse Grid are applied in developing textbook-efficient multigrid solvers for incompressible stagnation flow problems.
NASA UAS Integration into the NAS Project Detect and Avoid Display Evaluations
NASA Technical Reports Server (NTRS)
Shively, Jay
2016-01-01
As part of the Air Force - NASA Bi-Annual Research Council Meeting, slides will be presented on phase 1 Detect and Avoid (DAA) display evaluations. A series of iterative human-in-the-loops (HITL) experiments were conducted with different display configurations to objectively measure pilot performance on maintaining well clear. To date, four simulations and two mini-HITLs have been conducted. Data from these experiments have been incorporated into a revised alerting structure and included in the RTCA SC 228 Phase 1 Minimum Operational Performance Standards (MOPS) proposal. Plans for phase 2 are briefly discussed.
Simple force feedback for small virtual environments
NASA Astrophysics Data System (ADS)
Schiefele, Jens; Albert, Oliver; van Lier, Volker; Huschka, Carsten
1998-08-01
In today's civil flight training simulators only the cockpit and all its interaction devices exist as physical mockups. All other elements such as flight behavior, motion, sound, and the visual system are virtual. As an extension to this approach `Virtual Flight Simulation' tries to subsidize the cockpit mockup by a 3D computer generated image. The complete cockpit including the exterior view is displayed on a Head Mounted Display (HMD), a BOOM, or a Cave Animated Virtual Environment. In most applications a dataglove or virtual pointers are used as input devices. A basic problem of such a Virtual Cockpit simulation is missing force feedback. A pilot cannot touch and feel buttons, knobs, dials, etc. he tries to manipulate. As a result, it is very difficult to generate realistic inputs into VC systems. `Seating Bucks' are used in automotive industry to overcome the problem of missing force feedback. Only a seat, steering wheel, pedal, stick shift, and radio panel are physically available. All other geometry is virtual and therefore untouchable but visible in the output device. In extension to this concept a `Seating Buck' for commercial transport aircraft cockpits was developed. Pilot seat, side stick, pedals, thrust-levers, and flaps lever are physically available. All other panels are simulated by simple flat plastic panels. They are located at the same location as their real counterparts only lacking the real input devices. A pilot sees the entire photorealistic cockpit in a HMD as 3D geometry but can only touch the physical parts and plastic panels. In order to determine task performance with the developed Seating Buck, a test series was conducted. Users press buttons, adapt dials, and turn knobs. In a first test, a complete virtual environment was used. The second setting had a plastic panel replacing all input devices. Finally, as cross reference the participants had to repeat the test with a complete physical mockup of the input devices. All panels and physical devices can be easily relocated to simulate a different type of cockpit. Maximal 30 minutes are needed for a complete adaptation. So far, an Airbus A340 and a generic cockpit are supported.
NASA Technical Reports Server (NTRS)
Hess, R. A.
1976-01-01
Paramount to proper utilization of electronic displays is a method for determining pilot-centered display requirements. Display design should be viewed fundamentally as a guidance and control problem which has interactions with the designer's knowledge of human psychomotor activity. From this standpoint, reliable analytical models of human pilots as information processors and controllers can provide valuable insight into the display design process. A relatively straightforward, nearly algorithmic procedure for deriving model-based, pilot-centered display requirements was developed and is presented. The optimal or control theoretic pilot model serves as the backbone of the design methodology, which is specifically directed toward the synthesis of head-down, electronic, cockpit display formats. Some novel applications of the optimal pilot model are discussed. An analytical design example is offered which defines a format for the electronic display to be used in a UH-1H helicopter in a landing approach task involving longitudinal and lateral degrees of freedom.
Connected vehicle pilot deployment program.
DOT National Transportation Integrated Search
2014-01-01
The U.S. Department of Transportations (USDOTs) connected vehicle research program is a multimodal initiative to enable safe, interoperable, networked wireless communications among vehicles, infrastructure, and personal communications devices. ...
Flight Simulator Evaluation of Display Media Devices for Synthetic Vision Concepts
NASA Technical Reports Server (NTRS)
Arthur, J. J., III; Williams, Steven P.; Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.
2004-01-01
The Synthetic Vision Systems (SVS) Project of the National Aeronautics and Space Administration's (NASA) Aviation Safety Program (AvSP) is striving to eliminate poor visibility as a causal factor in aircraft accidents as well as enhance operational capabilities of all aircraft. To accomplish these safety and capacity improvements, the SVS concept is designed to provide a clear view of the world around the aircraft through the display of computer-generated imagery derived from an onboard database of terrain, obstacle, and airport information. Display media devices with which to implement SVS technology that have been evaluated so far within the Project include fixed field of view head up displays and head down Primary Flight Displays with pilot-selectable field of view. A simulation experiment was conducted comparing these display devices to a fixed field of view, unlimited field of regard, full color Helmet-Mounted Display system. Subject pilots flew a visual circling maneuver in IMC at a terrain-challenged airport. The data collected for this experiment is compared to past SVS research studies.
Investigation of the misfueling of reciprocating piston aircraft engines
NASA Technical Reports Server (NTRS)
Scott, J. Holland, Jr.
1988-01-01
The Aircraft Misfueling Detection Project was developed by the Goddard Space Flight Center/Wallops Flight Facility at Wallops Island, Virginia. Its purpose was to investigate the misfueling of reciprocating piston aircraft engines by the inadvertent introduction of jet fuel in lieu of or as a contaminant of aviation gasoline. The final objective was the development of a device(s) that will satisfactorily detect misfueling and provide pilots with sufficient warning to avoid injury, fatality, or equipment damage. Two devices have been developed and successfully tested: one, a small contamination detection kit, for use by the pilot, and a second, more sensitive, modified gas chromatograph for use by the fixed-base operator. The gas chromatograph, in addition to providing excellent quality control of the fixed-base operator's fuel handling, is a very good backup for the detection kit in the event it produces negative results. Design parameters were developed to the extent that they may be applied easily to commercial production by the aircraft industry.
Smith, Roger J
2008-10-01
A novel diagnostic technique for the remote and nonperturbative sensing of the local magnetic field in reactor relevant plasmas is presented. Pulsed polarimetry [Patent No. 12/150,169 (pending)] combines optical scattering with the Faraday effect. The polarimetric light detection and ranging (LIDAR)-like diagnostic has the potential to be a local B(pol) diagnostic on ITER and can achieve spatial resolutions of millimeters on high energy density (HED) plasmas using existing lasers. The pulsed polarimetry method is based on nonlocal measurements and subtle effects are introduced that are not present in either cw polarimetry or Thomson scattering LIDAR. Important features include the capability of simultaneously measuring local T(e), n(e), and B(parallel) along the line of sight, a resiliency to refractive effects, a short measurement duration providing near instantaneous data in time, and location for real-time feedback and control of magnetohydrodynamic (MHD) instabilities and the realization of a widely applicable internal magnetic field diagnostic for the magnetic fusion energy program. The technique improves for higher n(e)B(parallel) product and higher n(e) and is well suited for diagnosing the transient plasmas in the HED program. Larger devices such as ITER and DEMO are also better suited to the technique, allowing longer pulse lengths and thereby relaxing key technology constraints making pulsed polarimetry a valuable asset for next step devices. The pulsed polarimetry technique is clarified by way of illustration on the ITER tokamak and plasmas within the magnetized target fusion program within present technological means.
Advanced control concepts. [for shuttle ascent vehicles
NASA Technical Reports Server (NTRS)
Sharp, J. B.; Coppey, J. M.
1973-01-01
The problems of excess control devices and insufficient trim control capability on shuttle ascent vehicles were investigated. The trim problem is solved at all time points of interest using Lagrangian multipliers and a Simplex based iterative algorithm developed as a result of the study. This algorithm has the capability to solve any bounded linear problem with physically realizable constraints, and to minimize any piecewise differentiable cost function. Both solution methods also automatically distribute the command torques to the control devices. It is shown that trim requirements are unrealizable if only the orbiter engines and the aerodynamic surfaces are used.
UCSD Performance in the Edge Plasma Simulation (EPSI) Project. Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tynan, George Robert
This report contains a final report on the activities of UC San Diego PI G.R. Tynan and his collaborators as part of the EPSI Project, that was led by Dr. C.S. Chang, from PPPL. As a part of our work, we carried out several experiments on the ALCATOR C-MOD tokamak device, aimed at unraveling the “trigger” or cause of the spontaneous transition from low-mode confinement (L-mode) to high confinement (H-mode) that is universally observed in tokamak devices, and is planned for use in ITER.
Development of a Mobile App for Family Planning Providers.
Halsall, Viannella; Rogers, Jennifer; Witt, Jacki; Song, Sejun; Nguyen, Hoang Duc Huy; Kelly, Patricia
To provide an overview of lessons learned during the development process of an app for iOS and Android based on national recommendations for providing quality family planning services. After a review of existing apps was conducted to determine whether an app of clinical recommendations for family planning existed, a team of clinicians, training specialists, and app developers created a resource app by first drafting a comprehensive content map. A prototype of the app was then pilot tested using smart tablets by a volunteer convenience sample of women's healthcare professionals. Outcomes measured included usability, acceptability, download analytics, and satisfaction by clinicians as reported through an investigator-developed tool. Sixty-nine professionals tested a prototype of the app, and completed a user satisfaction tool. Overall, user feedback was positive, and a zoom function was added to the final version as a result of the pilot test. Within 3 months of being publicly available, the app was downloaded 677 times, with 97% of downloads occurring on smart phones, 76% downloads occurring on iOS devices, and 24% on Android devices. This trend persisted throughout the following 3 months. Clinicians with an interest in developing an app should consider a team approach to development, pilot test the app prior to wider distribution, and develop a web-based version of the app to be used by clinicians who are unable to access smart devices in their practice setting.
Dirler, Julia; Winkler, Gertrud; Lachenmeier, Dirk W
2018-06-01
The International Agency for Research on Cancer (IARC) evaluates "very hot (>65 °C) beverages" as probably carcinogenic to humans. However, there is a lack of research regarding what temperatures consumers actually perceive as "very hot" or as "too hot". A method for sensory analysis of such threshold temperatures was developed. The participants were asked to mix a very hot coffee step by step into a cooler coffee. Because of that, the coffee to be tasted was incrementally increased in temperature during the test. The participants took a sip at every addition, until they perceive the beverage as too hot for consumption. The protocol was evaluated in the form of a pilot study using 87 participants. Interestingly, the average pain threshold of the test group (67 °C) and the preferred drinking temperature (63 °C) iterated around the IARC threshold for carcinogenicity. The developed methodology was found as fit for the purpose and may be applied in larger studies.
Stein, Joel
2009-01-01
Therapy incorporating the repeated practice of motor tasks has been found to enhance motor function after stroke. This type of therapy may be facilitated by robotic devices and several such devices are being developed for use in rehabilitation. The Myomo e100 NeuroRobotic system is a novel device developed to provide assistance during elbow movements in stroke survivors. The device uses surface electromyographic signals to control a powered elbow orthosis. Data from a pilot study reveals that the device can be used successfully by stroke survivors and suggests that it may be effective in helping to restore motor control after stroke. Further studies are needed to confirm these preliminary results.
77 FR 6544 - Humanitarian Awards Pilot Program
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
..., medical diagnostics, water purification, more nutritious or higher-yield crops, pollution reduction, and... water filters, sterilization devices, and cleaner sources of energy for light, heat, cooking, or other...
Initial Development and Pilot Study Design of Interactive Lecture Demonstrations for ASTRO 101
NASA Astrophysics Data System (ADS)
Schwortz, Andria C.; French, D. A; Gutierrez, Joseph V; Sanchez, Richard L; Slater, Timothy F.; Tatge, Coty
2014-06-01
Interactive lecture demonstrations (ILDs) have repeatedly shown to be effective tools for improving student achievement in the context of learning physics. As a first step toward systematic development of interactive lecture demonstrations in ASTRO 101, the introductory astronomy survey course, a systematic review of education research, describing educational computer simulations (ECSs) reveals that initial development requires a targeted study of how ASTRO 101 students respond to ECSs in the non-science majoring undergraduate lecture setting. In this project we have adopted the process by which ILDs were designed, pilot-tested, and successfully implemented in the context of physics teaching (Sokoloff & Thornton, 1997; Sokoloff & Thornton, 2004). We have designed the initial pilot-test set of ASTRO 101 ILD instructional materials relying heavily on ECSs. Both an instructor’s manual and a preliminary classroom-ready student workbook have been developed, and we are implementing a pilot study to explore their effectiveness in communicating scientific content, and the extent to which they might enhance students’ knowledge of and perception about astronomy and science in general. The study design uses a pre-/post-test quasi-experimental study design measuring students’ normalized gain scores, calculated as per Hake (1998) and Prather (2009), using a slightly modified version of S. Slater’s (2011) Test Of Astronomy STandards TOAST combined with other instruments. The results of this initial study will guide the iterative development of ASTRO 101 ILDs that are intended to both be effective at enhancing student achievement and easy for instructors to successfully implement.
User Acceptability of Physiological and Other Measures of Hazardous States of Awareness
NASA Technical Reports Server (NTRS)
Dickinson, Terry L.; Milkulka, Peter J.; Kwan, Doris; Fitzgibbons, Amy A.; Jinadu, Florence R.; Freeman, Frederick G.; Scerbo, Mark W.; Pope, A. T. (Technical Monitor)
2001-01-01
Two studies explored user acceptance of devices that measure hazardous states of awareness. In the first study, critical incident data were collected in two workshops from 11 operators working as air traffic controllers or commercial pilots. These critical incident data were used to develop a survey of the acceptability of awareness measures. In the second study, the survey was administered to 100 people also working as air traffic controllers or commercial pilots. Results show that operators are open to the inclusion of technology to measure HSAs even if that technology is somewhat invasive as long as feedback about the HSAs is considered to be useful and helpful. Nonetheless, a major concern is the legal complications associated with being recorded, particularly for older and more experienced operators. Air traffic controllers emphasized the importance of sharing technology information with supervisors in order to receive backup or assistance under conditions of task overload, whereas pilots emphasized the influence of work schedules on problems with awareness. Recommendations are offered concerning the implementation of devices to measure hazardous states of awareness.
STS-46 Pilot Allen uses cycle ergometer on OV-104's middeck
1992-08-08
STS046-24-025 (31 July-8 Aug. 1992) --- Astronaut Andrew M. Allen, STS-46 pilot, exercises on the bicycle ergometer device on the flight deck of the Space Shuttle Atlantis as it makes one of its 127 total orbits for the eight-day mission. Allen, equipped with sensors for monitoring his biological systems during the run, was joined by four other NASA astronauts and two European scientists on the mission.
Integration Evaluation of the Advanced Mission Extender Device Max
2014-04-04
Figure 9. Pressure on collecting tube due to restraint harness design in left pilot seat of CH-47. The rating scores for comfort and functionality in...collecting tube due to restraint harness design in left pilot seat of CH-47. .......... 16 v Table of contents (continued) List of...USAF in 2009. The upgrades to the AMXDmax® included more automation, improvements to battery life, male cup comfort and collection bag design , plus a
Moisture vapor transport channels for the improved attachment of a medical device to the human body.
Cunningham, David D; Lowery, Michael G
2004-06-01
Attachment of a small, medical device to the human body for an extended period of time in an ambulatory setting requires the careful consideration of the physical form of the device and the physiological constraints limiting the time a device will stay on the skin. Factors such as the size of the device, the area of the device available for attachment to the skin, and the occlusive nature of the materials in the device are likely to affect adhesion. Here, plastic acrylic disks, 25 mm in diameter, containing a crisscross pattern of air-filled channels were tested on the forearm and abdomen using a moderately aggressive, unsupported, pressure-sensitive transfer adhesive in a pilot human clinical study. After vigorous exercise, droplets of moisture were observed in the channels followed by evaporation of the droplets over time. Disks without channels remained attached to the skin for about a day and a half, while disks containing 450 microm deep channels remained on the skin about three times longer. Little difference was found when the channel-to-channel spacing was increased from 1.3 to 1.6 mm, however 230 microm deep channels were less effective than 450 microm deep channels. Overall, the moisture vapor transport channels appear capable of reducing the moisture content of the outermost stratum corneum layer of the skin, increasing the strength of the stratum corneum, and increasing the time a device remains attached to the skin. The median trial-to-trial relative standard deviation of 45% observed in the pilot study can be used to design appropriately powered studies for the comparison of different device designs.
Pilot Program Evaluating Personal Tablet Device Use Across Campus
2012-01-01
that we had to individually activate the device through iTunes and manu- ally load the apps to the devices. As discussed below, the technology for...beginning of the effort, though, individual iTunes accounts were created for each of the students and tied to a domain email ad- dress provided by...required a USB connection to a computer in order to activate prior to use. We initially had a bank of laptops with iTunes installed that students
Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri
2017-11-21
In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests that the reader is usable among and can benefit a wide group of potential users, including in POC contexts. Generally, the methodology of this study demonstrates the importance of testing these types of systems with potential users and exemplifies how iterative design processes can be employed by multidisciplinary research teams to produce compelling technological solutions. ©Jess Hohenstein, Dakota O'Dell, Elizabeth L Murnane, Zhengda Lu, David Erickson, Geri Gay. Originally published in JMIR Human Factors (http://humanfactors.jmir.org), 21.11.2017.
Neumann, Thomas; Baum, Anne Katrin; Baum, Ulrike; Deike, Renate; Feistner, Helmut; Hinrichs, Hermann; Stokes, Joseph; Robra, Bernt-Peter
2018-01-01
The HOME ONE study is part of the larger HOME project, which aims to provide evidence of diagnostic and therapeutic yield ("change of management") of a patient-controlled portable EEG device with dry electrodes for the purposes of EEG home-monitoring neurological outpatients. The HOME ONE study is the first step in the process of investigating whether outpatient EEG home-monitoring changes the diagnosis and treatment of patients in comparison to conventional EEG ("change of management"). Both EEG devices (conventional and portable) will be systematically compared via a two-phase intra-individual assessment.In the first phase (pilot study phase), both EEG devices will be used within neurologist practices (all other things being equal). This pilot study (involving 130 patients) will evaluate the technical usability and efficacy of the new portable dry electrode EEG recorder in comparison to conventional EEG devices. Judgements will be based on technical assessments and EEG record examinations of private practitioners and two experienced neurologists (percent of concordant readings and kappa values).The second phase (feasibility study phase) aims to assess patients' acceptability and feasibility of the EEG home-monitoring and will provide insights into the extent diagnostic and therapeutic yields can be expected.For this purpose, a conventional EEG will be recorded in neurologist practices. Thereafter, the practice staff will instruct the patients on how the portable EEG device functions. The patients will subsequently use the devices in their home environment.The evaluation will compare the before and after documented diagnostic findings and the therapeutic consequences of the private practitioners with those of two experienced neurologists. To the best of our knowledge, this will be the first study of its kind to examine new approaches to diagnosing unclear consciousness disorders or other disorders of the CNS or the cardiovascular system through the use of a patient-controlled portable EEG device with dry electrodes for the purpose of home-monitoring neurological outpatients. If the two phases of the HOME ONE study provide sufficient evidence of diagnostic and therapeutic yields, this would justify (indication-specific) full-scale randomized controlled trials or observational studies. DRKS DRKS00012685. Registered 9 August 2017, retrospectively registered.
de Kroon, Marlou L A; Bulthuis, Jozien; Mulder, Wico; Schaafsma, Frederieke G; Anema, Johannes R
2016-12-01
Since the extent of sick leave and the problems of vocational school students are relatively large, we aimed to tailor a sick leave protocol at Dutch lower secondary education schools to the particular context of vocational schools. Four steps of the iterative process of Intervention Mapping (IM) to adapt this protocol were carried out: (1) performing a needs assessment and defining a program objective, (2) determining the performance and change objectives, (3) identifying theory-based methods and practical strategies and (4) developing a program plan. Interviews with students using structured questionnaires, in-depth interviews with relevant stakeholders, a literature research and, finally, a pilot implementation were carried out. A sick leave protocol was developed that was feasible and acceptable for all stakeholders. The main barriers for widespread implementation are time constraints in both monitoring and acting upon sick leave by school and youth health care. The iterative process of IM has shown its merits in the adaptation of the manual 'A quick return to school is much better' to a sick leave protocol for vocational school students.
Chatterji, Madhabi
2002-01-01
This study examines validity of data generated by the School Readiness for Reforms: Leader Questionnaire (SRR-LQ) using an iterative procedure that combines classical and Rasch rating scale analysis. Following content-validation and pilot-testing, principal axis factor extraction and promax rotation of factors yielded a five factor structure consistent with the content-validated subscales of the original instrument. Factors were identified based on inspection of pattern and structure coefficients. The rotated factor pattern, inter-factor correlations, convergent validity coefficients, and Cronbach's alpha reliability estimates supported the hypothesized construct properties. To further examine unidimensionality and efficacy of the rating scale structures, item-level data from each factor-defined subscale were subjected to analysis with the Rasch rating scale model. Data-to-model fit statistics and separation reliability for items and persons met acceptable criteria. Rating scale results suggested consistency of expected and observed step difficulties in rating categories, and correspondence of step calibrations with increases in the underlying variables. The combined approach yielded more comprehensive diagnostic information on the quality of the five SRR-LQ subscales; further research is continuing.
Stevens, Bonnie J; Nathan, Paul C; Seto, Emily; Cafazzo, Joseph A; Johnston, Donna L; Hum, Vanessa; Stinson, Jennifer N
2018-01-01
Background Pain in adolescents with cancer is common and negatively impacts health-related quality of life. The Pain Squad+ smartphone app, capable of providing adolescents with real-time pain management support, was developed to enhance pain management using a phased approach (ie, systematic review, consensus conference and vetting, iterative usability testing cycles). A 28-day Pain Squad+ pilot was conducted with 40 adolescents with cancer to evaluate the feasibility of implementing the app in a future clinical trial and to obtain estimates of treatment effect. Objective The objective of our nested qualitative study was to elucidate the perceptions of adolescents with cancer to determine the acceptability and perceived helpfulness of Pain Squad+, suggestions for app improvement, and satisfaction with the pilot study protocol. Methods Post pilot study participation, telephone-based, semistructured, and audio-recorded exit interviews were conducted with 20 adolescents with cancer (12-18 years). All interviews were transcribed and independently coded by 2 study team members. Content analysis was conducted to identify data categories and overarching themes. Results Five major themes comprising multiple categories and codes emerged. These themes focused on the acceptability of the intervention, acceptability of the study, the perceived active ingredients of the intervention, the suitability of the intervention to adolescents’ lives, and recommendations for intervention improvement. Conclusions Overall, Pain Squad+ and the pilot study protocol were acceptable to adolescents with cancer. Suggestions for intervention and study improvements will be incorporated into the design of a future randomized clinical trial (RCT) aimed at assessing the effectiveness of Pain Squad+ on adolescents with cancer health outcomes. PMID:29625951
Chruscicki, Adam; Badke, Katherin; Peddie, David; Small, Serena; Balka, Ellen; Hohl, Corinne M
2016-01-01
Adverse drug events (ADEs), harmful unintended consequences of medication use, are a leading cause of hospital admissions, yet are rarely documented in a structured format between care providers. We describe pilot-testing structured ADE documentation fields prior to integration into an electronic medical record (EMR). We completed a qualitative study at two Canadian hospitals. Using data derived from a systematic review of the literature, we developed screen mock-ups for an ADE reporting platform, iteratively revised in participatory workshops with diverse end-user groups. We designed a paper-based form reflecting the data elements contained in the mock-ups. We distributed them to a convenience sample of clinical pharmacists, and completed ethnographic workplace observations while the forms were used. We reviewed completed forms, collected feedback from pharmacists using semi-structured interviews, and coded the data in NVivo for themes related to the ADE form. We completed 25 h of clinical observations, and 24 ADEs were documented. Pharmacists perceived the form as simple and clear, with sufficient detail to capture ADEs. They identified fields for omission, and others requiring more detail. Pharmacists encountered barriers to documenting ADEs including uncertainty about what constituted a reportable ADE, inability to complete patient follow-up, the need for inter-professional communication to rule out alternative diagnoses, and concern about creating a permanent record. Paper-based pilot-testing allowed planning for important modifications in an ADE documentation form prior to implementation in an EMR. While paper-based piloting is rarely reported prior to EMR implementations, it can inform design and enhance functionality. Piloting with other groups of care providers and in different healthcare settings will likely lead to further revisions prior to broader implementations.
A parametric study of helium retention in beryllium and its effect on deuterium retention
NASA Astrophysics Data System (ADS)
Alegre, D.; Baldwin, M. J.; Simmonds, M.; Nishijima, D.; Hollmann, E. M.; Brezinsek, S.; Doerner, R. P.
2017-12-01
Beryllium samples have been exposed in the PISCES-B linear plasma device to conditions relevant to the International Thermonuclear Experimental Reactor (ITER) in pure He, D, and D/He mixed plasmas. Except at intermediate sample exposure temperatures (573-673 K) He addition to a D plasma is found to have a beneficial effect as it reduces the D retention in Be (up to ˜55%), although the mechanism is unclear. Retention of He is typically around 1020-1021 He m-2, and is affected primarily by the Be surface temperature during exposition, by the ion fluence at <500 K exposure, but not by the ion impact energy at 573 K. Contamination of the Be surface with high-Z elements from the mask of the sample holder in pure He plasmas is also observed under certain conditions, and leads to unexpectedly large He retention values, as well as changes in the surface morphology. An estimation of the tritium retention in the Be first wall of ITER is provided, being sufficiently low to allow a safe operation of ITER.
NASA Astrophysics Data System (ADS)
Ying, Changsheng; Zhao, Peng; Li, Ye
2018-01-01
The intensified charge-coupled device (ICCD) is widely used in the field of low-light-level (LLL) imaging. The LLL images captured by ICCD suffer from low spatial resolution and contrast, and the target details can hardly be recognized. Super-resolution (SR) reconstruction of LLL images captured by ICCDs is a challenging issue. The dispersion in the double-proximity-focused image intensifier is the main factor that leads to a reduction in image resolution and contrast. We divide the integration time into subintervals that are short enough to get photon images, so the overlapping effect and overstacking effect of dispersion can be eliminated. We propose an SR reconstruction algorithm based on iterative projection photon localization. In the iterative process, the photon image is sliced by projection planes, and photons are screened under the constraints of regularity. The accurate position information of the incident photons in the reconstructed SR image is obtained by the weighted centroids calculation. The experimental results show that the spatial resolution and contrast of our SR image are significantly improved.
Finite element analysis of heat load of tungsten relevant to ITER conditions
NASA Astrophysics Data System (ADS)
Zinovev, A.; Terentyev, D.; Delannay, L.
2017-12-01
A computational procedure is proposed in order to predict the initiation of intergranular cracks in tungsten with ITER specification microstructure (i.e. characterised by elongated micrometre-sized grains). Damage is caused by a cyclic heat load, which emerges from plasma instabilities during operation of thermonuclear devices. First, a macroscopic thermo-mechanical simulation is performed in order to obtain temperature- and strain field in the material. The strain path is recorded at a selected point of interest of the macroscopic specimen, and is then applied at the microscopic level to a finite element mesh of a polycrystal. In the microscopic simulation, the stress state at the grain boundaries serves as the marker of cracking initiation. The simulated heat load cycle is a representative of edge-localized modes, which are anticipated during normal operations of ITER. Normal stresses at the grain boundary interfaces were shown to strongly depend on the direction of grain orientation with respect to the heat flux direction and to attain higher values if the flux is perpendicular to the elongated grains, where it apparently promotes crack initiation.
Fast Time Response Electromagnetic Particle Injection System for Disruption Mitigation
NASA Astrophysics Data System (ADS)
Raman, Roger; Lay, W.-S.; Jarboe, T. R.; Menard, J. E.; Ono, M.
2017-10-01
Predicting and controlling disruptions is an urgent issue for ITER. In this proposed method, a radiative payload consisting of micro spheres of Be, BN, B, or other acceptable low-Z materials would be injected inside the q =2 surface for thermal and runaway electron mitigation. The radiative payload would be accelerated to the required velocities (0.2 to >1km/s) in an Electromagnetic Particle Injector (EPI). An important advantage of the EPI system is that it could be positioned very close to the reactor vessel. This has the added benefit that the external field near a high-field tokamak dramatically improves the injector performance, while simultaneously reducing the system response time. A NSTX-U / DIII-D scale system has been tested off-line to verify the critical parameters - the projected system response time and attainable velocities. Both are consistent with the model calculations, giving confidence that an ITER-scale system could be built to ensure safety of the ITER device. This work is supported by U.S. DOE Contracts: DE-AC02-09CH11466, DE-FG02-99ER54519 AM08, and DE-SC0006757.
Development and evaluation of a new taxonomy of mobility-related assistive technology devices.
Shoemaker, Laura L; Lenker, James A; Fuhrer, Marcus J; Jutai, Jeffrey W; Demers, Louise; DeRuyter, Frank
2010-10-01
This article reports on the development of a new taxonomy for mobility-related assistive technology devices. A prototype taxonomy was created based on the extant literature. Five mobility device experts were engaged in a modified Delphi process to evaluate and refine the taxonomy. Multiple iterations of expert feedback and revision yielded consensual agreement on the structure and terminology of a new mobility device taxonomy. The taxonomy uses a hierarchical framework to classify ambulation aids and wheeled mobility devices, including their key features that impact mobility. Five attributes of the new taxonomy differentiate it from previous mobility-related device classifications: (1) hierarchical structure, (2) primary device categories are grouped based on their intended mobility impact, (3) comprehensive inclusion of technical features, (4) a capacity to assimilate reimbursement codes, and (5) availability of a detailed glossary. The taxonomy is intended to support assistive technology outcomes research. The taxonomy will enable researchers to capture mobility-related assistive technology device interventions with precision and provide a common terminology that will allow comparisons among studies. The prominence of technical features within the new taxonomy will hopefully promote research that helps clinicians predict how devices will perform, thus aiding clinical decision making and supporting funding recommendations.
Ahrens, Brandon R [Albuquerque, NM; Todd, Steven N [Rio Rancho, NM
2009-04-28
A precision laser aiming system comprises a disrupter tool, a reflector, and a laser fixture. The disrupter tool, the reflector and the laser fixture are configurable for iterative alignment and aiming toward an explosive device threat. The invention enables a disrupter to be quickly and accurately set up, aligned, and aimed in order to render safe or to disrupt a target from a standoff position.
Community based participatory research of breastfeeding disparities in African American women.
Kulka, Tamar Ringel; Jensen, Elizabeth; McLaurin, Sue; Woods, Elizabeth; Kotch, Jonathan; Labbok, Miriam; Bowling, Mike; Dardess, Pamela; Baker, Sharon
2011-08-01
OBJECTIVE: Lack of support for breastfeeding mothers has been consistently identified in the literature as a barrier for breastfeeding across racial and ethnic groups. Using a community-based participatory approach, academic and community-based partners conducted an iterative process to assess barriers, facilitators and potential mediating interventions for breastfeeding in the African-American community in Durham, North Carolina. METHODS: Eight focus groups were conducted with African-American mothers, fathers and grandmothers. Researchers transcribed and coded each focus group and analyzed using Atlas ti. 5.2. Patterns and themes that emerged informed the development of community stakeholder interviews; 41 interviews were conducted with community representatives. These findings informed the development of a support group pilot intervention. The pilot support groups were evaluated for increase in knowledge of attendees. RESULTS: Focus group and community interviews indicate that African Americans may disproportionately experience inadequate support for breastfeeding. This lack of support was reported in the home, the workplace, among peers, and from healthcare providers. The pilot support groups resulted in increased knowledge of breastfeeding among group participants OR=3.6 (95% CI: 2.5, 5.2). CONCLUSIONS: The findings from this research underscore the importance of a multi-level approach to breastfeeding support for African American women to address breastfeeding disparities.
Evans, S; Walker-Bone, K; Otter, S
2015-03-01
Most studies of football injuries include professional players and data have been collected in without a single validated, standardised tool. We aimed to develop a new standardised questionnaire for assessing injuries among non-professional footballers and pilot its use. A questionnaire was developed using input from footballers, healthcare professionals and triangulation from the literature. The new tool was piloted among players representing amateurs and semi-professionals. Their comments were used iteratively to improve the instrument. The development phase produced a 33-item questionnaire collecting quantitative and qualitative data. In the pilot phase, 42 questionnaires were distributed, 34 (81%) returned. Respondents reported total of 273 football-related injuries, 114 affecting the foot/ankle (70 at the ankle and 44 at the foot). In total, 44% of respondents had suffered one or more foot/ankle injuries in the past 12 months. We developed a new standardised tool which we found to be well-completed by young male footballers in semi-professional and amateur settings with an excellent response rate. Our results suggested that foot/ankle injuries were common, larger studies in non-professionals are needed to identify risk factors for injury and develop pragmatic advice for prevention. Copyright © 2014 Elsevier Ltd. All rights reserved.
Pilot Deployment of the LDSD Parachute via a Supersonic Ballute
NASA Technical Reports Server (NTRS)
Tanner, Christopher L.; O'Farrell, Clara; Gallon, John C.; Clark, Ian G.; Witkowski, Allen; Woodruff, Paul
2015-01-01
The Low Density Supersonic Decelerator (LDSD) Project required the use of a pilot system due to the inability to mortar deploy its main supersonic parachute. A mortar deployed 4.4 m diameter supersonic ram-air ballute was selected as the pilot system for its high drag coefficient and stability relative to candidate supersonic parachutes at the targeted operational Mach number of 3. The ballute underwent a significant development program that included the development of a new liquid methanol-based pre-inflation system to assist the ballute inflation process. Both pneumatic and pyrotechnic mortar tests were conducted to verify orderly rigging deployment, bag strip, inflation aid activation, and proper mortar performance. The ballute was iteratively analyzed between fluid and structural analysis codes to obtain aerodynamic and aerothermodynamic estimates as well as estimates of the ballute's structural integrity and shape. The ballute was successfully flown in June 2014 at a Mach number of 2.73 as part of the first LDSD supersonic flight test and performed beyond expectations. Recovery of the ballute indicated that it did not exceed its structural or thermal capabilities. This flight set a historical precedent as it represented the largest ballute to have ever been successfully flown at this Mach number by a NASA entity.
Plasma wall interaction, a key issue on the way to a steady state burning fusion device
NASA Astrophysics Data System (ADS)
Philipps, V.
2006-04-01
The International Tokamak Experimental Reactor (ITER), the first burning fusion plasma experiment based on the tokamak principle, is ready for construction. It is based on many years of fusion research resulting in a robust design in most of the areas. Present day fusion research concentrates on the remaining critical issues which are, to a large extent, connected with processes of plasma wall interaction. This is mainly due to extended duty cycle and the increase of the plasma stored energy in comparison with present-day machines. Critical topics are the lifetime of the plasma facing components (PFC) and the long-term tritium retention. These processes are controlled mainly by material erosion, both during steady state operation and transient power losses (disruptions and edge localized modes (ELMs)) and short- and long-range material migration and re-deposition. The extrapolation from present-day 'full carbon wall' devices suggests that the long-term tritium retention in a burning fusion device would be unacceptably high under these conditions allowing for only an unacceptable limited number of pulses in a D T mixture. As a consequence of this, research activities have been strengthened to understand in more detail the underlying processes of material erosion and re-deposition, to develop methods to remove retained tritium from the PFCs and remote areas of a fusion device and to explore these processes and the plasma performance in more detail with metallic PFC, such as beryllium (Be) and tungsten (W), which are foreseen for the ITER experiment. This paper outlines the main physical mechanisms leading to material erosion, migration and re-deposition and the associated fuel retention. It addresses the experimental database in these areas and describes the further research strategies that will be needed to tackle critical issues.
Pillarisetti, Ajay; Allen, Tracy; Ruiz-Mercado, Ilse; Edwards, Rufus; Chowdhury, Zohir; Garland, Charity; Johnson, Michael; Litton, Charles D.; Lam, Nicholas L.; Pennise, David; Smith, Kirk R.
2017-01-01
Over the last 20 years, the Kirk R. Smith research group at the University of California Berkeley—in collaboration with Electronically Monitored Ecosystems, Berkeley Air Monitoring Group, and other academic institutions—has developed a suite of relatively inexpensive, rugged, battery-operated, microchip-based devices to quantify parameters related to household air pollution. These devices include two generations of particle monitors; data-logging temperature sensors to assess time of use of household energy devices; a time-activity monitoring system using ultrasound; and a CO2-based tracer-decay system to assess ventilation rates. Development of each system involved numerous iterations of custom hardware, software, and data processing and visualization routines along with both lab and field validation. The devices have been used in hundreds of studies globally and have greatly enhanced our understanding of heterogeneous household air pollution (HAP) concentrations and exposures and factors influencing them. PMID:28812989
Mixed Reality with HoloLens: Where Virtual Reality Meets Augmented Reality in the Operating Room.
Tepper, Oren M; Rudy, Hayeem L; Lefkowitz, Aaron; Weimer, Katie A; Marks, Shelby M; Stern, Carrie S; Garfein, Evan S
2017-11-01
Virtual reality and augmented reality devices have recently been described in the surgical literature. The authors have previously explored various iterations of these devices, and although they show promise, it has become clear that virtual reality and/or augmented reality devices alone do not adequately meet the demands of surgeons. The solution may lie in a hybrid technology known as mixed reality, which merges many virtual reality and augmented realty features. Microsoft's HoloLens, the first commercially available mixed reality device, provides surgeons intraoperative hands-free access to complex data, the real environment, and bidirectional communication. This report describes the use of HoloLens in the operating room to improve decision-making and surgical workflow. The pace of mixed reality-related technological development will undoubtedly be rapid in the coming years, and plastic surgeons are ideally suited to both lead and benefit from this advance.
Pillarisetti, Ajay; Allen, Tracy; Ruiz-Mercado, Ilse; Edwards, Rufus; Chowdhury, Zohir; Garland, Charity; Hill, L Drew; Johnson, Michael; Litton, Charles D; Lam, Nicholas L; Pennise, David; Smith, Kirk R
2017-08-16
Over the last 20 years, the Kirk R. Smith research group at the University of California Berkeley-in collaboration with Electronically Monitored Ecosystems, Berkeley Air Monitoring Group, and other academic institutions-has developed a suite of relatively inexpensive, rugged, battery-operated, microchip-based devices to quantify parameters related to household air pollution. These devices include two generations of particle monitors; data-logging temperature sensors to assess time of use of household energy devices; a time-activity monitoring system using ultrasound; and a CO₂-based tracer-decay system to assess ventilation rates. Development of each system involved numerous iterations of custom hardware, software, and data processing and visualization routines along with both lab and field validation. The devices have been used in hundreds of studies globally and have greatly enhanced our understanding of heterogeneous household air pollution (HAP) concentrations and exposures and factors influencing them.
Pehlivan, Ali Utku; Rose, Chad; O'Malley, Marcia K
2013-06-01
Rehabilitation of the distal joints of the upper extremities is crucial to restore the ability to perform activities of daily living to patients with neurological lesions resulting from stroke or spinal cord injury. Robotic rehabilitation has been identified as a promising new solution, however, much of the existing technology in this field is focused on the more proximal joints of the upper arm. A recently presented device, the RiceWrist-S, focuses on the rehabilitation of the forearm and wrist, and has undergone a few important design changes. This paper first addresses the design improvements achieved in the recent design iteration, and then presents the system characterization of the new device. We show that the RiceWrist-S has capabilities beyond other existing devices, and exhibits favorable system characteristics as a rehabilitation device, in particular torque output, range of motion, closed loop position performance, and high spatial resolution.
Friederichs, Hendrik; Marschall, Bernhard; Weissenstein, Anne
2014-12-05
Practicing evidence-based medicine is an important aspect of providing good medical care. Accessing external information through literature searches on computer-based systems can effectively achieve integration in clinical care. We conducted a pilot study using smartphones, tablets, and stationary computers as search devices at the bedside. The objective was to determine possible differences between the various devices and assess students' internet use habits. In a randomized controlled pilot study, 120 students were divided in three groups. One control group solved clinical problems on a computer and two intervention groups used mobile devices at the bedside. In a questionnaire, students were asked to report their internet use habits as well as their satisfaction with their respective search tool using a 5-point Likert scale. Of 120 surveys, 94 (78.3%) complete data sets were analyzed. The mobility of the tablet (3.90) and the smartphone (4.39) was seen as a significant advantage over the computer (2.38, p < .001). However, for performing an effective literature search at the bedside, the computer (3.22) was rated superior to both tablet computers (2.13) and smartphones (1.68). No significant differences were detected between tablets and smartphones except satisfaction with screen size (tablet 4.10, smartphone 2.00, p < .001). Using a mobile device at the bedside to perform an extensive search is not suitable for students who prefer using computers. However, mobility is regarded as a substantial advantage, and therefore future applications might facilitate quick and simple searches at the bedside.
PG&E WaveConnect Program Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brendan P. Dooher; Edward Cheslak; Robert Booth
The PG&E WaveConnect project was intended to demonstrate the technical and economic viability of wave power in the open ocean adjacent to PG&E's service territory. WaveConnect was conceived as a multi-stage development process leading to long-term megawatt-scale wave power production. The first-stage tasks consisted of site selection, permitting, pilot plant design, and assessment of technology and commercial readiness. The second stage would have included development of infrastructure, undersea cabling, and deployment of wave energy conversion devices (WECs). In the third stage, the most promising WEC devices would have been deployed in larger quantities and connected to the grid. This reportmore » documents the findings of Stage One. Site Selection: After studying the wave energy potential, grid interconnection and other project infrastructure along the California coast, PG&E selected two sites: one near Eureka, called the Humboldt WaveConnect (HWC) project, and another near Vandenberg Air Force Base, called the Central Coast WaveConnect project (CCWC). Permitting: FERC issued PG&E preliminary permits for HWC in 2008 and for CCWC in 2010. PG&E chose to use FERC's Pilot Project Licensing Process, which was intended to streamline licensing to allow relatively quick and easy installation, operation, and environmental testing for pilot projects. Permitting, however, proved to be complicated, time-consuming and expensive, mainly because of the uncertain impacts of WEC devices. PG&E learned that even under the PPLP the project would still require a full analysis under CEQA, including an EIR, as well as Monitoring and Adaptive Management Programs and other requirements that had significant cost and scheduling implications. A majority of efforts were expended on permitting activities. Pilot Plant Design: PG&E prepared a conceptual design for a 5-MW pilot test facility at the Humboldt site, which consisted of an off-shore deployment area where WECs of different designs and from different device manufacturers could be tested. PG&E was to provide permitting, subsea cables, and on-shore facilities necessary to connect WaveConnect to an existing PG&E substation, while the WEC manufacturers would provide, operate and maintain their devices during the test period. Technology and Commercial Readiness: PG&E issued a Request for Information to the wave power industry to assess the technical and commercial capabilities of WEC manufacturers. Sixteen manufacturers responded, representing the four best-known and most mature designs. PG&E found that WECs are early-stage devices with evolving designs and little real-world operating experience. These characteristics made environmental impacts difficult to assess, which complicated permitting efforts. It also made a megawatt-scale demonstration project difficult to support because early stage WECs are costly and have limited track records for performance and reliability. Results: PG&E withdrew its FERC DPLA for HWC in November 2010 and surrendered its preliminary permit for CCWC in May 2011, effectively discontinuing the project for the following combination of reasons: Permitting issues were much more challenging than originally anticipated. Stage One project funding of $6 million proved insufficient to complete the necessary development and permitting work. During Stage One development, PG&E determined that permitting costs would be $2 million to $5 million greater than originally budgeted. The cost of developing a five-year, 5-MW pilot project at Humboldt Bay is much greater than the $15 million to $20 million originally estimated. Even assuming that vendors provide WEC devices at no cost to the utility, which was the proposed strategy with WaveConnect, PG&E concluded that a pilot project comparable to HWC would cost approximately $47 million. If WEC devices were purchased for such a project, its total cost would be on the order of $90 million. It is unclear when or if wave power will become competitive with renewable energy alternatives. Significant additional investment in design, testing and demonstration will be needed to improve designs and reduce costs. Using a vendor-provided installed cost goal of $2500/kW for mature WECs in five to 10 years, PG&E concluded that their LCOE would be in the range of $175-$250/MWh, which is not competitive with current or near-term renewable alternatives such as wind or solar photovoltaics. Although PG&E discontinued the project and no WEC devices were deployed, WaveConnect advanced PG&E's understanding of the technological, engineering, permitting, environmental, economic, stakeholder, and related issues involved in undertaking any wave power project now or in the future. As WEC technologies mature, and regulatory and permitting agencies grow more familiar with their environmental impacts, PG&E believes that wave power will merit further evaluation, demonstration and deployment.« less
Modeling of the ITER-like wide-angle infrared thermography view of JET.
Aumeunier, M-H; Firdaouss, M; Travère, J-M; Loarer, T; Gauthier, E; Martin, V; Chabaud, D; Humbert, E
2012-10-01
Infrared (IR) thermography systems are mandatory to ensure safe plasma operation in fusion devices. However, IR measurements are made much more complicated in metallic environment because of the spurious contributions of the reflected fluxes. This paper presents a full predictive photonic simulation able to assess accurately the surface temperature measurement with classical IR thermography from a given plasma scenario and by taking into account the optical properties of PFCs materials. This simulation has been carried out the ITER-like wide angle infrared camera view of JET in comparing with experimental data. The consequences and the effects of the low emissivity and the bidirectional reflectivity distribution function used in the model for the metallic PFCs on the contribution of the reflected flux in the analysis are discussed.
A three-dimensional wide-angle BPM for optical waveguide structures.
Ma, Changbao; Van Keuren, Edward
2007-01-22
Algorithms for effective modeling of optical propagation in three- dimensional waveguide structures are critical for the design of photonic devices. We present a three-dimensional (3-D) wide-angle beam propagation method (WA-BPM) using Hoekstra's scheme. A sparse matrix algebraic equation is formed and solved using iterative methods. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation, along with a technique for shifting the simulation window to reduce the dimension of the numerical equation and a threshold technique to further ensure its convergence. These techniques can ensure the implementation of iterative methods for waveguide structures by relaxing the convergence problem, which will further enable us to develop higher-order 3-D WA-BPMs based on Padé approximant operators.
Self-adaptive demodulation for polarization extinction ratio in distributed polarization coupling.
Zhang, Hongxia; Ren, Yaguang; Liu, Tiegen; Jia, Dagong; Zhang, Yimo
2013-06-20
A self-adaptive method for distributed polarization extinction ratio (PER) demodulation is demonstrated. It is characterized by dynamic PER threshold coupling intensity (TCI) and nonuniform PER iteration step length (ISL). Based on the preset PER calculation accuracy and original distribution coupling intensity, TCI and ISL can be made self-adaptive to determine contributing coupling points inside the polarizing devices. Distributed PER is calculated by accumulating those coupling points automatically and selectively. Two different kinds of polarization-maintaining fibers are tested, and PERs are obtained after merely 3-5 iterations using the proposed method. Comparison experiments with Thorlabs commercial instrument are also conducted, and results show high consistency. In addition, the optimum preset PER calculation accuracy of 0.05 dB is obtained through many repeated experiments.
A three-dimensional wide-angle BPM for optical waveguide structures
NASA Astrophysics Data System (ADS)
Ma, Changbao; van Keuren, Edward
2007-01-01
Algorithms for effective modeling of optical propagation in three- dimensional waveguide structures are critical for the design of photonic devices. We present a three-dimensional (3-D) wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme. A sparse matrix algebraic equation is formed and solved using iterative methods. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation, along with a technique for shifting the simulation window to reduce the dimension of the numerical equation and a threshold technique to further ensure its convergence. These techniques can ensure the implementation of iterative methods for waveguide structures by relaxing the convergence problem, which will further enable us to develop higher-order 3-D WA-BPMs based on Padé approximant operators.
Evaluation of Adaptive Subdivision Method on Mobile Device
NASA Astrophysics Data System (ADS)
Rahim, Mohd Shafry Mohd; Isa, Siti Aida Mohd; Rehman, Amjad; Saba, Tanzila
2013-06-01
Recently, there are significant improvements in the capabilities of mobile devices; but rendering large 3D object is still tedious because of the constraint in resources of mobile devices. To reduce storage requirement, 3D object is simplified but certain area of curvature is compromised and the surface will not be smooth. Therefore a method to smoother selected area of a curvature is implemented. One of the popular methods is adaptive subdivision method. Experiments are performed using two data with results based on processing time, rendering speed and the appearance of the object on the devices. The result shows a downfall in frame rate performance due to the increase in the number of triangles with each level of iteration while the processing time of generating the new mesh also significantly increase. Since there is a difference in screen size between the devices the surface on the iPhone appears to have more triangles and more compact than the surface displayed on the iPad. [Figure not available: see fulltext.
RMP ELM Suppression in DIII-D Plasmas with ITER Similar Shapes and Collisionalities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, T.E.; Fenstermacher, M. E.; Moyer, R.A.
2008-01-01
Large Type-I edge localized modes (ELMs) are completely eliminated with small n = 3 resonant magnetic perturbations (RMP) in low average triangularity, = 0.26, plasmas and in ITER similar shaped (ISS) plasmas, = 0.53, with ITER relevant collisionalities ve 0.2. Significant differences in the RMP requirements and in the properties of the ELM suppressed plasmas are found when comparing the two triangularities. In ISS plasmas, the current required to suppress ELMs is approximately 25% higher than in low average triangularity plasmas. It is also found that the width of the resonant q95 window required for ELM suppression is smaller inmore » ISS plasmas than in low average triangularity plasmas. An analysis of the positions and widths of resonant magnetic islands across the pedestal region, in the absence of resonant field screening or a self-consistent plasma response, indicates that differences in the shape of the q profile may explain the need for higher RMP coil currents during ELM suppression in ISS plasmas. Changes in the pedestal profiles are compared for each plasma shape as well as with changes in the injected neutral beam power and the RMP amplitude. Implications of these results are discussed in terms of requirements for optimal ELM control coil designs and for establishing the physics basis needed in order to scale this approach to future burning plasma devices such as ITER.« less
Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J
2011-04-01
Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the collection and assessment of environmental and occupational research data.
Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
2010-01-01
Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR). This device has been designed to provide full range of motion (ROM) for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05) between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05). Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P < 0.001) and 24 ± 6% (P = 0.041) for the fingers and thumb, respectively. Conclusions Our pilot study shows that this device is capable of moving the hand's digits through nearly the entire ROM with physiologically accurate trajectories. Stroke subjects received the device intervention well and device impedance was minimized so that subjects could freely extend and flex their digits inside of HEXORR. Our active force-assisted condition was successful in increasing the subjects' ROM while promoting active participation. PMID:20667083
A real-time plantar pressure feedback device for foot unloading.
Femery, Virginie G; Moretto, Pierre G; Hespel, Jean-Michel G; Thévenon, André; Lensel, Ghislaine
2004-10-01
To develop and test a plantar pressure control device that provides both visual and auditory feedback and is suitable for correcting plantar pressure distribution patterns in persons susceptible to neuropathic foot ulceration. Pilot test. Sports medicine laboratory in a university in France. One healthy man in his mid thirties. Not applicable. Main outcome measures A device was developed based on real-time feedback, incorporating an acoustic alarm and visual signals, adjusted to a specific pressure load. Plantar pressure measured during walking, at 6 sensor locations over 27 steps under 2 different conditions: (1) natural and (2) unloaded in response to device feedback. The subject was able to modify his gait in response to the auditory and visual signals. He did not compensate for the decrease of peak pressure under the first metarsal by increasing the duration of the load shift under this area. Gait pattern modification centered on a mediolateral load shift. The auditory signal provided a warning system alerting the user to potentially harmful plantar pressures. The visual signal warned of the degree of pressure. People who have lost nociceptive perception, as in cases of diabetic neuropathy, may be able to change their walking pattern in response to the feedback provided by this device. The visual may have diagnostic value in determining plantar pressures in such patients. This pilot test indicates that further studies are warranted.
Kaiser, Peter K; Wang, Yi-Zhong; He, Yu-Guang; Weisberger, Annemarie; Wolf, Stephane; Smith, Craig H
2013-10-01
This pilot study evaluated the feasibility of the Health Management Tool (HMT), a novel computing system using mobile handheld devices, to remotely monitor retinal visual function daily in patients with neovascular age-related macular degeneration treated with ranibizumab. Patients with neovascular age-related macular degeneration in at least 1 eye (newly diagnosed or successfully treated < 1 year) and eligible for ranibizumab therapy were enrolled in this 16-week, prospective, open-label, single-arm study. Patients performed a shape discrimination hyperacuity test (myVisionTrack [mVT]) daily on the HMT device (iPhone 3GS) remotely and at all clinic visits. Data entered into HMT devices were collected in the HMT database, which also sent reminders for patients to take mVT. Among 160 patients from 24 U.S. centers enrolled in the study (103 [64%] ≥ 75 years of age), 84.7% on average complied with daily mVT testing and ≈ 98.9% complied with at least weekly mVT testing. The HMT database successfully uploaded more than 17,000 mVT assessment values and sent more than 9,000 reminders. Elderly patients with neovascular age-related macular degeneration were willing and able to comply with daily self-testing of retinal visual function using mobile handheld devices in this novel system of remote vision monitoring.
Mansikka, Heikki; Virtanen, Kai; Harris, Don
2018-04-30
The sensitivity of NASA-TLX scale, modified Cooper-Harper (MCH) scale and the mean inter-beat interval (IBI) of successive heart beats, as measures of pilot mental workload (MWL), were evaluated in a flight training device (FTD). Operational F/A-18C pilots flew instrument approaches with varying task loads. Pilots' performance, subjective MWL ratings and IBI were measured. Based on the pilots' performance, three performance categories were formed; high-, medium- and low-performance. Values of the subjective rating scales and IBI were compared between categories. It was found that all measures were able to differentiate most task conditions and there was a strong, positive correlation between NASA-TLX and MCH scale. An explicit link between IBI, NASA-TLX, MCH and performance was demonstrated. While NASA-TLX, MCH and IBI have all been previously used to measure MWL, this study is the first one to investigate their association in a modern FTD, using a realistic flying mission and operational pilots.
IEEE 1588 Time Synchronization Board in MTCA.4 Form Factor
NASA Astrophysics Data System (ADS)
Jabłoński, G.; Makowski, D.; Mielczarek, A.; Orlikowski, M.; Perek, P.; Napieralski, A.; Makijarvi, P.; Simrock, S.
2015-06-01
Distributed data acquisition and control systems in large-scale scientific experiments, like e.g. ITER, require time synchronization with nanosecond precision. A protocol commonly used for that purpose is the Precise Timing Protocol (PTP), also known as IEEE 1588 standard. It uses the standard Ethernet signalling and protocols and allows obtaining timing accuracy of the order of tens of nanoseconds. The MTCA.4 is gradually becoming the platform of choice for building such systems. Currently there is no commercially available implementation of the PTP receiver on that platform. In this paper, we present a module in the MTCA.4 form factor supporting this standard. The module may be used as a timing receiver providing reference clocks in an MTCA.4 chassis, generating a Pulse Per Second (PPS) signal and allowing generation of triggers and timestamping of events on 8 configurable backplane lines and two front panel connectors. The module is based on the Xilinx Spartan 6 FPGA and thermally stabilized Voltage Controlled Oscillator controlled by the digital-to-analog converter. The board supports standalone operation, without the support from the host operating system, as the entire control algorithm is run on a Microblaze CPU implemented in the FPGA. The software support for the card includes the low-level API in the form of Linux driver, user-mode library, high-level API: ITER Nominal Device Support and EPICS IOC. The device has been tested in the ITER timing distribution network (TCN) with three cascaded PTP-enabled Hirschmann switches and a GPS reference clock source. An RMS synchronization accuracy, measured by direct comparison of the PPS signals, better than 20 ns has been obtained.
Blignaut, P J; McDonald, T; Tolmie, C J
2001-05-01
A prototyping approach was used to determine the essential system requirements of a computerised patient record information system for a typical township primary health care clinic. A pilot clinic was identified and the existing manual system and business processes in this clinic was studied intensively before the first prototype was implemented. Interviews with users, incidental observations and analysis of actual data entered were used as primary techniques to refine the prototype system iteratively until a system with an acceptable data set and adequate functionalities were in place. Several non-functional and user-related requirements were also discovered during the prototyping period.
Photoionization cross section by Stieltjes imaging applied to coupled cluster Lanczos pseudo-spectra
NASA Astrophysics Data System (ADS)
Cukras, Janusz; Coriani, Sonia; Decleva, Piero; Christiansen, Ove; Norman, Patrick
2013-09-01
A recently implemented asymmetric Lanczos algorithm for computing (complex) linear response functions within the coupled cluster singles (CCS), coupled cluster singles and iterative approximate doubles (CC2), and coupled cluster singles and doubles (CCSD) is coupled to a Stieltjes imaging technique in order to describe the photoionization cross section of atoms and molecules, in the spirit of a similar procedure recently proposed by Averbukh and co-workers within the Algebraic Diagrammatic Construction approach. Pilot results are reported for the atoms He, Ne, and Ar and for the molecules H2, H2O, NH3, HF, CO, and CO2.
Cukras, Janusz; Coriani, Sonia; Decleva, Piero; Christiansen, Ove; Norman, Patrick
2013-09-07
A recently implemented asymmetric Lanczos algorithm for computing (complex) linear response functions within the coupled cluster singles (CCS), coupled cluster singles and iterative approximate doubles (CC2), and coupled cluster singles and doubles (CCSD) is coupled to a Stieltjes imaging technique in order to describe the photoionization cross section of atoms and molecules, in the spirit of a similar procedure recently proposed by Averbukh and co-workers within the Algebraic Diagrammatic Construction approach. Pilot results are reported for the atoms He, Ne, and Ar and for the molecules H2, H2O, NH3, HF, CO, and CO2.
The REFINEMENT Glossary of Terms: An International Terminology for Mental Health Systems Assessment.
Montagni, Ilaria; Salvador-Carulla, Luis; Mcdaid, David; Straßmayr, Christa; Endel, Florian; Näätänen, Petri; Kalseth, Jorid; Kalseth, Birgitte; Matosevic, Tihana; Donisi, Valeria; Chevreul, Karine; Prigent, Amélie; Sfectu, Raluca; Pauna, Carmen; Gutiérrez-Colosia, Mencia R; Amaddeo, Francesco; Katschnig, Heinz
2018-03-01
Comparing mental health systems across countries is difficult because of the lack of an agreed upon terminology covering services and related financing issues. Within the European Union project REFINEMENT, international mental health care experts applied an innovative mixed "top-down" and "bottom-up" approach following a multistep design thinking strategy to compile a glossary on mental health systems, using local services as pilots. The final REFINEMENT glossary consisted of 432 terms related to service provision, service utilisation, quality of care and financing. The aim of this study was to describe the iterative process and methodology of developing this glossary.
NASA Technical Reports Server (NTRS)
Reichelt, Mark
1993-01-01
In this paper we describe a novel generalized SOR (successive overrelaxation) algorithm for accelerating the convergence of the dynamic iteration method known as waveform relaxation. A new convolution SOR algorithm is presented, along with a theorem for determining the optimal convolution SOR parameter. Both analytic and experimental results are given to demonstrate that the convergence of the convolution SOR algorithm is substantially faster than that of the more obvious frequency-independent waveform SOR algorithm. Finally, to demonstrate the general applicability of this new method, it is used to solve the differential-algebraic system generated by spatial discretization of the time-dependent semiconductor device equations.
Kang, Seung-Gul; Kang, Jae Myeong; Cho, Seong-Jin; Ko, Kwang-Pil; Lee, Yu Jin; Lee, Heon-Jeong; Kim, Leen; Winkelman, John W
2017-04-15
The use of telemedicine with a mobile application (MA) and a wearable device (WD) for the management of sleep disorders has recently received considerable attention. We designed an MA synchronizable with a WD for insomnia treatment. Our pilot study determined the efficacy of simplified group cognitive behavioral therapy for insomnia (CBT-I) delivered using our MA and assessed participant adherence to and satisfaction with the device. The efficacy of the CBT-I using MA (CBT-I-MA) was assessed by comparing sleep variables (sleep efficiency [SE], Insomnia Severity Index [ISI], and Pittsburgh Sleep Quality Inventory [PSQI] scores) before and after a 4-week treatment protocol in 19 patients with insomnia disorder patients. SE was assessed using a sleep diary, actigraphy, and the PSQI. The intervention significantly improved all three measures of SE ( P < .05), and the response rate to treatment was high (94.7%). Total ISI and PSQI scores and sleep latency, as measured by the sleep diary, improved significantly. Participants showed relatively good adherence to our MA, and sleep diary entries were made on 24.3 ± 3.8 of 28 days. Moreover, 94.7% of the participants reported that our MA was effective for treating insomnia. Our pilot study suggested the clinical usefulness of a CBT-I-MA. We expect that our findings will lead to further development and replication studies of CBT-I-MA. © 2017 American Academy of Sleep Medicine
Developing a pressure ulcer risk assessment scale for patients in long-term care.
Lepisto, Mervi; Eriksson, Elina; Hietanen, Helvi; Lepisto, Jyri; Lauri, Sirkka
2006-02-01
Previous pressure ulcer risk assessment scales appear to have relied on opinions about risk factors and are based on care setting rather than research evidence. Utilizing 21 existing risk assessment scales and relevant risk factor literature, an instrument was developed by Finnish researchers that takes into account individual patient risk factors, devices and methods applied in nursing care, and organizational characteristics. The instrument underwent two pilot tests to assess the relevance and clarity of the instrument: the first involved 43 nurses and six patients; the second involved 50 nurses with expertise in wound care. Changes to questionnaire items deemed necessary as a result of descriptive analysis and agreement percentages were completed. After pilot testing, the final instrument addressed the following issues: 1) patient risks: activity, mobility in bed, mental status, nutrition, urinary incontinence, fecal incontinence, sensory perception, and skin condition; 2) devices and methods used in patient care: technical devices, bed type, mattress, overlay, seat cushions, and care methods; and 3) staff number and structure, maximum number of beds, and beds in use (the last group of questions were included to ensure participants understood the items; results were not analyzed). The phases of the study provided an expeditious means of data collection and a suitable opportunity to assess how the instrument would function in practice. Instrument reliability and validity were improved as a result of the pilot testing and can be enhanced further with continued use and assessment.
Factors related to pilot survival in helicopter commuter and air taxi crashes.
Krebs, M B; Li, G; Baker, S P
1995-02-01
We examined factors related to pilot survival in 167 consecutive helicopter commuter and air taxi crashes that occurred during 1983-88. Case fatality rates and adjusted odds ratios from multivariate logistic regression models were determined using data from the National Transportation Safety Board (NTSB). During this 6-year period, 29 pilots-in-command died in 167 helicopter commuter and air taxi crashes, a case fatality rate of 17.4%. Factors significantly associated with increased risk of pilot fatality were aircraft fire [odds ratio (OR) 20.0, 95% confidence interval (CI) 4.6-86.8], not using shoulder harnesses (OR 9.2, 95% CI 2.2-37.3), and aircraft with two engines (OR 4.8, 95% CI 1.3-17.4). In addition, we present data regarding success and failure of emergency flotation devices. The results suggest that the likelihood of pilot survival in helicopter crashes could be greatly improved by preventing crash associated fires and promoting the usage of shoulder restraints.
NASA Astrophysics Data System (ADS)
Maraschek, M.; Gude, A.; Igochine, V.; Zohm, H.; Alessi, E.; Bernert, M.; Cianfarani, C.; Coda, S.; Duval, B.; Esposito, B.; Fietz, S.; Fontana, M.; Galperti, C.; Giannone, L.; Goodman, T.; Granucci, G.; Marelli, L.; Novak, S.; Paccagnella, R.; Pautasso, G.; Piovesan, P.; Porte, L.; Potzel, S.; Rapson, C.; Reich, M.; Sauter, O.; Sheikh, U.; Sozzi, C.; Spizzo, G.; Stober, J.; Treutterer, W.; ZancaP; ASDEX Upgrade Team; TCV Team; the EUROfusion MST1 Team
2018-01-01
Routine reaction to approaching disruptions in tokamaks is currently largely limited to machine protection by mitigating an ongoing disruption, which remains a basic requirement for ITER and DEMO [1]. Nevertheless, a mitigated disruption still generates stress to the device. Additionally, in future fusion devices, high-performance discharge time itself will be very valuable. Instead of reacting only on generic features, occurring shortly before the disruption, the ultimate goal is to actively avoid approaching disruptions at an early stage, sustain the discharges whenever possible and restrict mitigated disruptions to major failures. Knowledge of the most relevant root causes and the corresponding chain of events leading to disruption, the disruption path, is a prerequisite. For each disruption path, physics-based sensors and adequate actuators must be defined and their limitations considered. Early reaction facilitates the efficiency of the actuators and enhances the probability of a full recovery. Thus, sensors that detect potential disruptions in time are to be identified. Once the entrance into a disruption path is detected, we propose a hierarchy of actions consisting of (I) recovery of the discharge to full performance or at least continuation with a less disruption-prone backup scenario, (II) complete avoidance of disruption to sustain the discharge or at least delay it for a controlled termination and, (III), only as last resort, a disruption mitigation. Based on the understanding of disruption paths, a hierarchical and path-specific handling strategy must be developed. Such schemes, testable in present devices, could serve as guidelines for ITER and DEMO operation. For some disruption paths, experiments have been performed at ASDEX Upgrade and TCV. Disruptions were provoked in TCV by impurity injection into ELMy H-mode discharges and in ASDEX Upgrade by forcing a density limit in H-mode discharges. The new approach proposed in this paper is discussed for these cases. For the H-mode density limit sensors used so far react too late. Thus a plasma-state boundary is proposed, that can serve as an adequate early sensor for avoiding density limit disruptions in H-modes and for recovery to full performance.
Packaging of silicon photonic devices: from prototypes to production
NASA Astrophysics Data System (ADS)
Morrissey, Padraic E.; Gradkowski, Kamil; Carroll, Lee; O'Brien, Peter
2018-02-01
The challenges associated with the photonic packaging of silicon devices is often underestimated and remains technically challenging. In this paper, we review some key enabling technologies that will allow us to overcome the current bottleneck in silicon photonic packaging; while also describing the recent developments in standardisation, including the establishment of PIXAPP as the worlds first open-access PIC packaging and assembly Pilot Line. These developments will allow the community to move from low volume prototype photonic packaged devices to large scale volume manufacturing, where the full commercialisation of PIC technology can be realised.
Handheld computers and the 21st century surgical team: a pilot study.
Aziz, Omer; Panesar, Sukhmeet S; Netuveli, Gopalakrishnan; Paraskeva, Paraskevas; Sheikh, Aziz; Darzi, Ara
2005-08-18
The commercial development and expansion of mobile phone networks has led to the creation of devices combining mobile phones and personal digital assistants, which could prove invaluable in a clinical setting. This pilot study aimed to look at how one such device compared with the current pager system in facilitating inter-professional communication in a hospital clinical team. The study looked at a heterogeneous team of doctors (n = 9) working in a busy surgical setting at St. Mary's Hospital in London and compared the use of a personal digital assistant with mobile phone and web-browsing facilities to the existing pager system. The primary feature of this device being compared to the conventional pager was its use as a mobile phone, but other features evaluated included the ability to access the internet, and reference data on the device. A crossover study was carried out for 6 weeks in 2004, with the team having access to the personal digital assistant every alternate week. The primary outcome measure for assessing efficiency of communication was the length of time it took for clinicians to respond to a call. We also sought to assess the ease of adoption of new technology by evaluating the perceptions of the team (n = 9) to personal digital assistants, by administering a questionnaire. Doctors equipped with a personal digital assistant rather than a pager, responded more quickly to a call and had a lower of failure to respond rate (RR: 0.44; 95%CI 0.20-0.93). Clinicians also found this technology easy to adopt as seen by a significant reduction in perceptions of nervousness to the technology over the six-week study period (mean (SD) week 1: 4.10 (SD 1.69) vs. mean (SD) week 6: 2.20 (1.99); p = 0.04). The results of this pilot study show the possible effects of replacing the current hospital pager with a newer, more technologically advanced device, and suggest that a combined personal digital assistant and mobile phone device may improve communication between doctors. In the light of these encouraging preliminary findings, we propose a large-scale clinical trial of the use of these devices in facilitating inter-professional communication in a hospital setting.
Evaluation of an Airborne Spacing Concept, On-Board Spacing Tool, and Pilot Interface
NASA Technical Reports Server (NTRS)
Swieringa, Kurt; Murdoch, Jennifer L.; Baxley, Brian; Hubbs, Clay
2011-01-01
The number of commercial aircraft operations is predicted to increase in the next ten years, creating a need for improved operational efficiency. Two areas believed to offer significant increases in efficiency are optimized profile descents and dependent parallel runway operations. It is envisioned that during both of these types of operations, flight crews will precisely space their aircraft behind preceding aircraft at air traffic control assigned intervals to increase runway throughput and maximize the use of existing infrastructure. This paper describes a human-in-the-loop experiment designed to study the performance of an onboard spacing algorithm and pilots ratings of the usability and acceptability of an airborne spacing concept that supports dependent parallel arrivals. Pilot participants flew arrivals into the Dallas Fort-Worth terminal environment using one of three different simulators located at the National Aeronautics and Space Administration s (NASA) Langley Research Center. Scenarios were flown using Interval Management with Spacing (IM-S) and Required Time of Arrival (RTA) control methods during conditions of no error, error in the forecast wind, and offset (disturbance) to the arrival flow. Results indicate that pilots delivered their aircraft to the runway threshold within +/- 3.5 seconds of their assigned arrival time and reported that both the IM-S and RTA procedures were associated with low workload levels. In general, pilots found the IM-S concept, procedures, speeds, and interface acceptable; with 92% of pilots rating the procedures as complete and logical, 218 out of 240 responses agreeing that the IM-S speeds were acceptable, and 63% of pilots reporting that the displays were easy to understand and displayed in appropriate locations. The 22 (out of 240) responses, indicating that the commanded speeds were not acceptable and appropriate occurred during scenarios containing wind error and offset error. Concerns cited included the occurrence of multiple speed changes within a short time period, speed changes required within twenty miles of the runway, and an increase in airspeed followed shortly by a decrease in airspeed. Within this paper, appropriate design recommendations are provided, and the need for continued, iterative human-centered design is discussed.
[Telerehabilitation to treat stress urinary incontinence. Pilot study].
Carrión Pérez, Francisca; Rodríguez Moreno, María Sofía; Carnerero Córdoba, Lidia; Romero Garrido, Marina C; Quintana Tirado, Laura; García Montes, Inmaculada
2015-05-21
We aimed to test a new telerehabilitation device for stress urinary incontinence (SUI) in order to make an initial assessment of its effectiveness. Randomized, controlled pilot study. experimental group (10 patients): pelvic floor muscle training, device training and home treatment with it; control group (9 patients): conventional rehabilitation treatment. Outcome measures (baseline and 3 months) overall and specific quality of life: International Consultation Incontinence Questionnaire and King's Health Questionnaire, bladder diary, perineometry, satisfaction with the program and degree of compliance. Baseline characteristics were similar in both groups. There was no statistically significant difference for any outcome measures between groups at the end of the follow-up. The change in perineometry values at baseline and after the intervention was significant in the experimental group (23.06 to 32.00, P=.011). No group in this study had any serious adverse effects. The tested device is safe and well accepted. Although there is some evidence of its efficacy in the rehabilitation treatment of SUI, larger trials are needed to appropriately evaluate the potential advantages. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aldridge, Chris D.
Mobile biometric devices (MBDs) capable of both enrolling individuals in databases and performing identification checks of subjects in the field are seen as an important capability for military, law enforcement, and homeland security operations. The technology is advancing rapidly. The Department of Homeland Security Science and Technology Directorate through an Interagency Agreement with Sandia sponsored a series of pilot projects to obtain information for the first responder law enforcement community on further identification of requirements for mobile biometric device technology. Working with 62 different jurisdictions, including components of the Department of Homeland Security, Sandia delivered a series of reports onmore » user operation of state-of-the-art mobile biometric devices. These reports included feedback information on MBD usage in both operational and exercise scenarios. The findings and conclusions of the project address both the limitations and possibilities of MBD technology to improve operations. Evidence of these possibilities can be found in the adoption of this technology by many agencies today and the cooperation of several law enforcement agencies in both participating in the pilot efforts and sharing of information about their own experiences in efforts undertaken separately.« less
Twin-Screw Extruder Development for the ITER Pellet Injection System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk
The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pelletsmore » used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ≈5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ≈15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.« less
Recommendations and Privacy Requirements for a Bring-Your-Own-Device User Policy and Agreement
2015-03-01
manipulate data from non-traditional workplaces to support mission requirements. The United States Marine Corps (USMC) has started a pilot BYOD program, but...contrasted to obtain a starting point to develop a user agreement for the USMC. The security controls identified within these case studies were also...participating in a BYOD program. A. MARINE CORPS PILOT PROGRAM Starting in January 2015 and at the behest of the USMC, the Marine Corps Network Operations and
Toward New Horizons. Volume 1. Science - the Key to Air Supremacy
1945-12-15
By V.R. Sean I. L. Ashkei" C N. Hascrt Part II! - AIRCRAFT MATERIALS AND STRUCTURES > By N. M. Ncwmark v l/FUTÜ« AIRBORNI A«Mli...FUTURE TRENDS IN THE DESIGN AND DEVELOPMENT OF SOUD AND LIQUID FUEL ROCKETS H. 6. Taien Pan V —HIGH TEMPERATURE MATERIALS By Pol Dnwei VI/1MCI VA!!t...the automatic pilot, which materially relieves the hiunan pilot. In addition, the development of gryo and servo- motor devices made possible a great
Lin, Li-Fong; Lin, Yi-Jia; Lin, Zi-Hao; Chuang, Li-Yun; Hsu, Wei-Chun; Lin, Yuan-Hsiang
2017-06-19
Wearable devices based on inertial measurement units through wireless sensor networks have many applications such as real-time motion monitoring and functional outcome assessment of stroke rehabilitation. However, additional investigations are warranted to validate their clinical value, particularly in detecting the synergy patterns of movements after stroke. To explore the feasibility and efficacy of wearable devices for upper limb rehabilitation in patients with chronic stroke and to compare the intervention effects (e.g., neurological recovery, active range of motion, and deviation angle) with those in a control group. A single-blind, randomized-controlled pilot study. Rehabilitation ward. A total of 18 patients with chronic stroke were randomly distributed into a device group and control group. Both groups received conventional rehabilitation; nevertheless, the device group was additionally subjected to 15 daily sessions at least three times a week for 5 weeks. The outcome measures included the upper extremity subscores of the Fugl-Meyer assessment, active range of motion, and deviation angle. These measurements were performed pre- and post-treatment. All five Fugl-Meyer assessment subscores improved in both the device and control groups after intervention; in particular, the "shoulder/elbow/forearm" subscore (p = 0.02, 0.03) and "total score" (p = 0.03, 0.03) substantially improved. The active range of motion of shoulder flexion and abduction substantially improved at pre-post treatment in both the device (p = 0.02, 0.03) and control (p = 0.02, 0.03) groups. The deviation angle of shoulder external rotation during shoulder abduction substantially improved in the device group (p = 0.02), but not in the control group. The designed wearable devices are practical and efficient for use in chronic patients with stroke. Wearable devices are expected to be useful for future internet-of-things rehabilitation clinical trials at home and in long-term care institutions.
NASA Astrophysics Data System (ADS)
Schenone, D. J.; Igama, S.; Marash-Whitman, D.; Sloan, C.; Okansinski, A.; Moffet, A.; Grace, J. M.; Gentry, D.
2015-12-01
Experimental evolution of microorganisms in controlled microenvironments serves as a powerful tool for understanding the relationship between micro-scale microbial interactions as well as local-to global-scale environmental factors. In response to iterative and targeted environmental pressures, mutagenesis drives the emergence of novel phenotypes. Current methods to induce expression of these phenotypes require repetitive and time intensive procedures and do not allow for the continuous monitoring of conditions such as optical density, pH and temperature. To address this shortcoming, an Automated Dynamic Directed Evolution Chamber is being developed. It will initially produce Escherichia coli cells with an elevated UV-C resistance phenotype that will ultimately be adapted for different organisms as well as studying environmental effects. A useful phenotype and environmental factor for examining this relationship is UV-C resistance and exposure. In order to build a baseline for the device's operational parameters, a UV-C assay was performed on six E. coli replicates with three exposure fluxes across seven iterations. The fluxes included a 0 second exposure (control), 6 seconds at 3.3 J/m2/s and 40 seconds at 0.5 J/m2/s. After each iteration the cells were regrown and tested for UV-C resistance. We sought to quantify the increase and variability of UV-C resistance among different fluxes, and observe changes in each replicate at each iteration in terms of variance. Under different fluxes, we observed that the 0s control showed no significant increase in resistance, while the 6s/40s fluxes showed increased resistance as the number of iterations increased. A one-million fold increase in survivability was observed after seven iterations. Through statistical analysis using Spearman's rank correlation, the 40s exposure showed signs of more consistently increased resistance, but seven iterations was insufficient to demonstrate statistical significance; to test this further, our experiments will include more iterations. Furthermore, we plan to sequence all the replicants. As adaptation dynamics under intense UV exposure leads to high rate of change, it would be useful to observe differences in tolerance-related and non-tolerance-related genes between the original and UV resistant strains.
ERIC Educational Resources Information Center
Mercurio, Marco; Torre, Ilaria; Torsani, Simone
2014-01-01
The paper describes a module within the distance language learning environment of the Language Centre at the Genoa University which adapts, through an ontology, learning activities to the device in use. Adaptation means not simply resizing a page but also the ability to transform the nature of a task so that it fits the device with the smallest…
2012-03-01
ch1) IED Improvised Explosive Device (ch1) IMS Integrated Master Schedule (ch3) ISR Intelligence Surveillance Reconnaissance (ch1...including the locating, monitoring, and neutralizing of enemy combatants, identification of and detonation of improvised explosive devices (IED...typically high altitude) necessitating the use of costly optics and sensors for ISR data collection. These features preclude long endurance RPAs from being
Advanced density profile reflectometry; the state-of-the-art and measurement prospects for ITER
NASA Astrophysics Data System (ADS)
Doyle, E. J.
2006-10-01
Dramatic progress in millimeter-wave technology has allowed the realization of a key goal for ITER diagnostics, the routine measurement of the plasma density profile from millimeter-wave radar (reflectometry) measurements. In reflectometry, the measured round-trip group delay of a probe beam reflected from a plasma cutoff is used to infer the density distribution in the plasma. Reflectometer systems implemented by UCLA on a number of devices employ frequency-modulated continuous-wave (FM-CW), ultrawide-bandwidth, high-resolution radar systems. One such system on DIII-D has routinely demonstrated measurements of the density profile over a range of electron density of 0-6.4x10^19,m-3, with ˜25 μs time and ˜4 mm radial resolution, meeting key ITER requirements. This progress in performance was made possible by multiple advances in the areas of millimeter-wave technology, novel measurement techniques, and improved understanding, including: (i) fast sweep, solid-state, wide bandwidth sources and power amplifiers, (ii) dual polarization measurements to expand the density range, (iii) adaptive radar-based data analysis with parallel processing on a Unix cluster, (iv) high memory depth data acquisition, and (v) advances in full wave code modeling. The benefits of advanced system performance will be illustrated using measurements from a wide range of phenomena, including ELM and fast-ion driven mode dynamics, L-H transition studies and plasma-wall interaction. The measurement capabilities demonstrated by these systems provide a design basis for the development of the main ITER profile reflectometer system. This talk will explore the extent to which these reflectometer system designs, results and experience can be translated to ITER, and will identify what new studies and experimental tests are essential.
Tziraki, Chariklia; Berenbaum, Rakel; Gross, Daniel; Abikhzer, Judith; Ben-David, Boaz M
2017-07-31
The field of serious games for people with dementia (PwD) is mostly driven by game-design principals typically applied to games created by and for younger individuals. Little has been done developing serious games to help PwD maintain cognition and to support functionality. We aimed to create a theory-based serious game for PwD, with input from a multi-disciplinary team familiar with aging, dementia, and gaming theory, as well as direct input from end users (the iterative process). Targeting enhanced self-efficacy in daily activities, the goal was to generate a game that is acceptable, accessible and engaging for PwD. The theory-driven game development was based on the following learning theories: learning in context, errorless learning, building on capacities, and acknowledging biological changes-all with the aim to boost self-efficacy. The iterative participatory process was used for game screen development with input of 34 PwD and 14 healthy community dwelling older adults, aged over 65 years. Development of game screens was informed by the bio-psychological aging related disabilities (ie, motor, visual, and perception) as well as remaining neuropsychological capacities (ie, implicit memory) of PwD. At the conclusion of the iterative development process, a prototype game with 39 screens was used for a pilot study with 24 PwD and 14 healthy community dwelling older adults. The game was played twice weekly for 10 weeks. Quantitative analysis showed that the average speed of successful screen completion was significantly longer for PwD compared with healthy older adults. Both PwD and controls showed an equivalent linear increase in the speed for task completion with practice by the third session (P<.02). Most important, the rate of improved processing speed with practice was not statistically different between PwD and controls. This may imply that some form of learning occurred for PwD at a nonsignificantly different rate than for controls. Qualitative results indicate that PwD found the game engaging and fun. Healthy older adults found the game too easy. Increase in self-reported self-efficacy was documented with PwD only. Our study demonstrated that PwD's speed improved with practice at the same rate as healthy older adults. This implies that when tasks are designed to match PwD's abilities, learning ensues. In addition, this pilot study of a serious game, designed for PwD, was accessible, acceptable, and enjoyable for end users. Games designed based on learning theories and input of end users and a multi-disciplinary team familiar with dementia and aging may have the potential of maintaining capacity and improving functionality of PwD. A larger longer study is needed to confirm our findings and evaluate the use of these games in assessing cognitive status and functionality. ©Chariklia Tziraki, Rakel Berenbaum, Daniel Gross, Judith Abikhzer, Boaz M Ben-David. Originally published in JMIR Serious Games (http://games.jmir.org), 31.07.2017.
Gross, Daniel; Abikhzer, Judith
2017-01-01
Background The field of serious games for people with dementia (PwD) is mostly driven by game-design principals typically applied to games created by and for younger individuals. Little has been done developing serious games to help PwD maintain cognition and to support functionality. Objectives We aimed to create a theory-based serious game for PwD, with input from a multi-disciplinary team familiar with aging, dementia, and gaming theory, as well as direct input from end users (the iterative process). Targeting enhanced self-efficacy in daily activities, the goal was to generate a game that is acceptable, accessible and engaging for PwD. Methods The theory-driven game development was based on the following learning theories: learning in context, errorless learning, building on capacities, and acknowledging biological changes—all with the aim to boost self-efficacy. The iterative participatory process was used for game screen development with input of 34 PwD and 14 healthy community dwelling older adults, aged over 65 years. Development of game screens was informed by the bio-psychological aging related disabilities (ie, motor, visual, and perception) as well as remaining neuropsychological capacities (ie, implicit memory) of PwD. At the conclusion of the iterative development process, a prototype game with 39 screens was used for a pilot study with 24 PwD and 14 healthy community dwelling older adults. The game was played twice weekly for 10 weeks. Results Quantitative analysis showed that the average speed of successful screen completion was significantly longer for PwD compared with healthy older adults. Both PwD and controls showed an equivalent linear increase in the speed for task completion with practice by the third session (P<.02). Most important, the rate of improved processing speed with practice was not statistically different between PwD and controls. This may imply that some form of learning occurred for PwD at a nonsignificantly different rate than for controls. Qualitative results indicate that PwD found the game engaging and fun. Healthy older adults found the game too easy. Increase in self-reported self-efficacy was documented with PwD only. Conclusions Our study demonstrated that PwD’s speed improved with practice at the same rate as healthy older adults. This implies that when tasks are designed to match PwD’s abilities, learning ensues. In addition, this pilot study of a serious game, designed for PwD, was accessible, acceptable, and enjoyable for end users. Games designed based on learning theories and input of end users and a multi-disciplinary team familiar with dementia and aging may have the potential of maintaining capacity and improving functionality of PwD. A larger longer study is needed to confirm our findings and evaluate the use of these games in assessing cognitive status and functionality. PMID:28760730
Re-use of pilot data and interim analysis of pivotal data in MRMC studies: a simulation study
NASA Astrophysics Data System (ADS)
Chen, Weijie; Samuelson, Frank; Sahiner, Berkman; Petrick, Nicholas
2017-03-01
Novel medical imaging devices are often evaluated with multi-reader multi-case (MRMC) studies in which radiologists read images of patient cases for a specified clinical task (e.g., cancer detection). A pilot study is often used to measure the effect size and variance parameters that are necessary for sizing a pivotal study (including sizing readers, non-diseased and diseased cases). Due to the practical difficulty of collecting patient cases or recruiting clinical readers, some investigators attempt to include the pilot data as part of their pivotal study. In other situations, some investigators attempt to perform an interim analysis of their pivotal study data based upon which the sample sizes may be re-estimated. Re-use of the pilot data or interim analyses of the pivotal data may inflate the type I error of the pivotal study. In this work, we use the Roe and Metz model to simulate MRMC data under the null hypothesis (i.e., two devices have equal diagnostic performance) and investigate the type I error rate for several practical designs involving re-use of pilot data or interim analysis of pivotal data. Our preliminary simulation results indicate that, under the simulation conditions we investigated, the inflation of type I error is none or only marginal for some design strategies (e.g., re-use of patient data without re-using readers, and size re-estimation without using the effect-size estimated in the interim analysis). Upon further verifications, these are potentially useful design methods in that they may help make a study less burdensome and have a better chance to succeed without substantial loss of the statistical rigor.
Macromolecular Crystallization in Microfluidics for the International Space Station
NASA Technical Reports Server (NTRS)
Monaco, Lisa A.; Spearing, Scott
2003-01-01
At NASA's Marshall Space Flight Center, the Iterative Biological Crystallization (IBC) project has begun development on scientific hardware for macromolecular crystallization on the International Space Station (ISS). Currently ISS crystallization research is limited to solution recipes that were prepared on the ground prior to launch. The proposed hardware will conduct solution mixing and dispensing on board the ISS, be fully automated, and have imaging functions via remote commanding from the ground. Utilizing microfluidic technology, IBC will allow for on orbit iterations. The microfluidics LabChip(R) devices that have been developed, along with Caliper Technologies, will greatly benefit researchers by allowing for precise fluid handling of nano/pico liter sized volumes. IBC will maximize the amount of science return by utilizing the microfluidic approach and be a valuable tool to structural biologists investigating medically relevant projects.
Automation under suspicion--case flight AF-447 Air France.
Martins, Edgard; Soares, Marcelo
2012-01-01
The probes allow the pilot to control the aircraft speed was essential to the balance of the flight. Opinions of experts who claim that "the design of the plane would have exercised a not inconsiderable role in the occurrence of a disaster." These messages revealed a series of important operating errors in a zone of turbulence, "making the plane uncontrollable, leading to a rapid depressurization device, according to these reports. A lawsuit in Toulouse and in Brazil aims to recognition of the liability of Air France and Airbus not insignificant role in the design and operation of the aircraft in the event of catastrophe. Opinions are taken from senior pilots that no commercial aviation training for certain situations abnormal flight that, if realized, could have influenced the pilots of the AF-447 to remove the plane's fatal dive show what experiments performed in simulators for military pilots, who are permanently subject to critical flight situations.
LED instrument approach instruction display
NASA Technical Reports Server (NTRS)
Meredith, B. D.; Kelly, W. L., IV; Crouch, R. K.
1979-01-01
A display employing light emitting diodes (LED's) was developed to demonstrate the feasibility of such displays for presenting landing and navigation information to reduce the workload of general aviation pilots during IFR flight. The display consists of a paper tape reader, digital memory, control electronics, digital latches, and LED alphanumeric displays. A presentable digital countdown clock-timer is included as part of the system to provide a convenient means of monitoring time intervals for precise flight navigation. The system is a limited capability prototype assembled to test pilot reaction to such a device under simulated IFR operation. Pilot opinion indicates that the display is helpful in reducing the IFR pilots workload when used with a runway approach plate. However, the development of a compact, low power second generation display was recommended which could present several instructions simultaneously and provide information update capability. A microprocessor-based display could fulfill these requirements.
Pilots' Visual Scan Patterns and Attention Distribution During the Pursuit of a Dynamic Target.
Yu, Chung-San; Wang, Eric Min-Yang; Li, Wen-Chin; Braithwaite, Graham; Greaves, Matthew
2016-01-01
The current research was to investigate pilots' visual scan patterns in order to assess attention distribution during air-to-air maneuvers. A total of 30 qualified mission-ready fighter pilots participated in this research. Eye movement data were collected by a portable head-mounted eye-tracking device, combined with a jet fighter simulator. To complete the task, pilots had to search for, pursue, and lock on a moving target while performing air-to-air tasks. There were significant differences in pilots' saccade duration (ms) in three operating phases, including searching (M = 241, SD = 332), pursuing (M = 311, SD = 392), and lock-on (M = 191, SD = 226). Also, there were significant differences in pilots' pupil sizes (pixel(2)), of which the lock-on phase was the largest (M = 27,237, SD = 6457), followed by pursuit (M = 26,232, SD = 6070), then searching (M = 25,858, SD = 6137). Furthermore, there were significant differences between expert and novice pilots in the percentage of fixation on the head-up display (HUD), time spent looking outside the cockpit, and the performance of situational awareness (SA). Experienced pilots have better SA performance and paid more attention to the HUD, but focused less outside the cockpit when compared with novice pilots. Furthermore, pilots with better SA performance exhibited a smaller pupil size during the operational phase of lock on while pursuing a dynamic target. Understanding pilots' visual scan patterns and attention distribution are beneficial to the design of interface displays in the cockpit and in developing human factors training syllabi to improve the safety of flight operations.
Statthaler, Karina; Schwarz, Andreas; Steyrl, David; Kobler, Reinmar; Höller, Maria Katharina; Brandstetter, Julia; Hehenberger, Lea; Bigga, Marvin; Müller-Putz, Gernot
2017-12-28
In this work, we share our experiences made at the world-wide first CYBATHLON, an event organized by the Eidgenössische Technische Hochschule Zürich (ETH Zürich), which took place in Zurich in October 2016. It is a championship for severely motor impaired people using assistive prototype devices to compete against each other. Our team, the Graz BCI Racing Team MIRAGE91 from Graz University of Technology, participated in the discipline "Brain-Computer Interface Race". A brain-computer interface (BCI) is a device facilitating control of applications via the user's thoughts. Prominent applications include assistive technology such as wheelchairs, neuroprostheses or communication devices. In the CYBATHLON BCI Race, pilots compete in a BCI-controlled computer game. We report on setting up our team, the BCI customization to our pilot including long term training and the final BCI system. Furthermore, we describe CYBATHLON participation and analyze our CYBATHLON result. We found that our pilot was compliant over the whole time and that we could significantly reduce the average runtime between start and finish from initially 178 s to 143 s. After the release of the final championship specifications with shorter track length, the average runtime converged to 120 s. We successfully participated in the qualification race at CYBATHLON 2016, but performed notably worse than during training, with a runtime of 196 s. We speculate that shifts in the features, due to the nonstationarities in the electroencephalogram (EEG), but also arousal are possible reasons for the unexpected result. Potential counteracting measures are discussed. The CYBATHLON 2016 was a great opportunity for our student team. We consolidated our theoretical knowledge and turned it into practice, allowing our pilot to play a computer game. However, further research is required to make BCI technology invariant to non-task related changes of the EEG.
Seebregts, Christopher J; Zwarenstein, Merrick; Mathews, Catherine; Fairall, Lara; Flisher, Alan J; Seebregts, Clive; Mukoma, Wanjiru; Klepp, Knut-Inge
2009-11-01
Handheld computers (personal digital assistant, PDA) have the potential to reduce the logistic burden, cost, and error rate of paper-based health research data collection, but there is a lack of appropriate software. The present work describes the development and evaluation of PDACT, a Personal Data Collection Toolset (www.healthware.org/pdact/index.htm) for the Palm Pilot handheld computer for interviewer-administered and respondent-administered data collection. We developed Personal Data Collection Toolkit (PDACT) software to enable questionnaires developed in QDS Design Studio, a Windows application, to be compiled and completed on Palm Pilot devices and evaluated in several representative field survey settings. The software has been used in seven separate studies and in over 90,000 interviews. Five interviewer-administered studies were completed in rural settings with poor communications infrastructure, following one day of interviewer training. Two respondent-administered questionnaire studies were completed by learners, in urban secondary schools, after 15min training. Questionnaires were available on each handheld in up to 11 languages, ranged from 20 to 580 questions, and took between 15 and 90min to complete. Up to 200 Palm Pilot devices were in use on a single day and, in about 50 device-years of use, very few technical problems were found. Compared with paper-based collection, data validation and cleaning times were reduced, and fewer errors were found. PDA data collection is easy to use and preferred by interviewers and respondents (both respondent-administered and interviewer-administered) over paper. Data are compiled and available within hours of collection facilitating data quality assurance. Although hardware increases the setup cost of the first study, the cumulative cost falls thereafter, and converges on the cumulative cost of paper-based studies (four, in the case of our interviewer-administered studies). Handheld data collection is an appropriate, affordable and convenient technology for health data collection, in diverse settings.
Jiang, Rui; McKanna, James; Calabrese, Samantha; Seif El-Nasr, Magy
2017-08-01
Herein we describe a methodology for developing a game-based intervention to raise awareness of Chlamydia and other sexually transmitted infections among youth in Boston's underserved communities. We engaged in three design-based experiments. These utilized mixed methods, including playtesting and assessment methods, to examine the overall effectiveness of the game. In this case, effectiveness is defined as (1) engaging the target group, (2) increasing knowledge about Chlamydia, and (3) changing attitudes toward Chlamydia testing. These three experiments were performed using participants from different communities and with slightly different versions of the game, as we iterated through the design/feedback process. Overall, participants who played the game showed a significant increase in participants' knowledge of Chlamydia compared with those in the control group (P = 0.0002). The version of the game, including elements specifically targeting systemic thinking, showed significant improvement in participants' intent to get tested compared with the version of the game without such elements (Stage 2: P > 0.05; Stage 3: P = 0.0045). Furthermore, during both Stage 2 and Stage 3, participants showed high levels of enjoyment, mood, and participation and moderate levels of game engagement and social engagement. During Stage 3, however, participants' game engagement (P = 0.0003), social engagement (P = 0.0003), and participation (P = 0.0003) were significantly higher compared with those of Stage 2. Thus, we believe that motivation improvements from Stage 2 to 3 were also effective. Finally, participants' overall learning effectiveness was correlated with their prepositive affect (r = 0.52) and their postproblem hierarchy (r = -0.54). The game improved considerably from its initial conception through three stages of iterative design and feedback. Our assessment methods for each stage targeted and integrated learning, health, and engagement outcomes. Lessons learned through this iterative design process are a great contribution to the games for health community, especially in targeting the development of health and learning goals through game design.
Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study.
Imai, Rumi; Miyazaki, Osamu; Horiuchi, Tetsuya; Asano, Keisuke; Nishimura, Gen; Sago, Haruhiko; Nosaka, Shunsuke
2017-06-01
Prenatal diagnosis of skeletal dysplasia by means of 3D skeletal CT examination is highly accurate. However, it carries a risk of fetal exposure to radiation. Model-based iterative reconstruction (MBIR) technology can reduce radiation exposure; however, to our knowledge, the lower limit of an optimal dose is currently unknown. The objectives of this study are to establish ultra-low-dose fetal CT as a method for prenatal diagnosis of skeletal dysplasia and to evaluate the appropriate radiation dose for ultra-low-dose fetal CT. Relationships between tube current and image noise in adaptive statistical iterative reconstruction and MBIR were examined using a 32-cm CT dose index (CTDI) phantom. On the basis of the results of this examination and the recommended methods for the MBIR option and the known relationship between noise and tube current for filtered back projection, as represented by the expression SD = (milliamperes) -0.5 , the lower limit of the optimal dose in ultra-low-dose fetal CT with MBIR was set. The diagnostic power of the CT images obtained using the aforementioned scanning conditions was evaluated, and the radiation exposure associated with ultra-low-dose fetal CT was compared with that noted in previous reports. Noise increased in nearly inverse proportion to the square root of the dose in adaptive statistical iterative reconstruction and in inverse proportion to the fourth root of the dose in MBIR. Ultra-low-dose fetal CT was found to have a volume CTDI of 0.5 mGy. Prenatal diagnosis was accurately performed on the basis of ultra-low-dose fetal CT images that were obtained using this protocol. The level of fetal exposure to radiation was 0.7 mSv. The use of ultra-low-dose fetal CT with MBIR led to a substantial reduction in radiation exposure, compared with the CT imaging method currently used at our institution, but it still enabled diagnosis of skeletal dysplasia without reducing diagnostic power.
Mechanical Characterization of the Iter Mock-Up Insulation after Reactor Irradiation
NASA Astrophysics Data System (ADS)
Prokopec, R.; Humer, K.; Fillunger, H.; Maix, R. K.; Weber, H. W.
2010-04-01
The ITER mock-up project was launched in order to demonstrate the feasibility of an industrial impregnation process using the new cyanate ester/epoxy blend. The mock-up simulates the TF winding pack cross section by a stainless steel structure with the same dimensions as the TF winding pack at a length of 1 m. It consists of 7 plates simulating the double pancakes, each of them is wrapped with glass fiber/Kapton sandwich tapes. After stacking the 7 plates, additional insulation layers are wrapped to simulate the ground insulation. This paper presents the results of the mechanical quality tests on the mock-up pancake insulation. Tensile and short beam shear specimens were cut from the plates extracted from the mock-up and tested at 77 K using a servo-hydraulic material testing device. All tests were repeated after reactor irradiation to a fast neutron fluence of 1×1022 m-2 (E>0.1 MeV). In order to simulate the pulsed operation of ITER, tension-tension fatigue measurements were performed in the load controlled mode. Initial results show a high mechanical strength as expected from the high number of thin glass fiber layers, and an excellent homogeneity of the material.
DiMES PMI research at DIII-D in support of ITER and beyond
Rudakov, Dimitry L.; Abrams, Tyler; Ding, Rui; ...
2017-03-27
An overview of recent Plasma-Material Interactions (PMI) research at the DIII-D tokamak using the Divertor Material Evaluation System (DiMES) is presented. The DiMES manipulator allows for exposure of material samples in the lower divertor of DIII-D under well-diagnosed ITER-relevant plasma conditions. Plasma parameters during the exposures are characterized by an extensive diagnostic suite including a number of spectroscopic diagnostics, Langmuir probes, IR imaging, and Divertor Thomson Scattering. Post-mortem measurements of net erosion/deposition on the samples are done by Ion Beam Analysis, and results are modelled by the ERO and REDEP/WBC codes with plasma background reproduced by OEDGE/DIVIMP modelling based onmore » experimental inputs. This article highlights experiments studying sputtering erosion, re-deposition and migration of high-Z elements, mostly tungsten and molybdenum, as well as some alternative materials. Results are generally encouraging for use of high-Z PFCs in ITER and beyond, showing high redeposition and reduced net sputter erosion. Two methods of high-Z PFC surface erosion control, with (i) external electrical biasing and (ii) local gas injection, are also discussed. Furthermore, these techniques may find applications in the future devices.« less
NASA Astrophysics Data System (ADS)
Cui, L.; Grierson, B.; Logan, N.; Nazikian, R.
2016-10-01
Application of RMPs to low collisionality (ν*e < 0.4) ITER shape plasmas on DIII-D leads to a rapid reduction in stored energy due to density pumpout that is sometimes followed by a gradual recovery in the plasma stored energy. Understanding this confinement recovery is essential to optimize the confinement of RMP plasmas in present and future devices such as ITER. Transport modeling using TRANSP+TGLF indicates that the core a/LTi is stiff in these plasmas while the ion temperature gradient is much less stiff in the pedestal region. The reduction in the edge density during pumpout leads to an increase in the core ion temperature predicted by TGLF based on experimental data. This is correlated to the increase in the normalized ion heat flux. Transport stiffness in the core combined with an increase in the edge a/LTi results in an increase of the plasma stored energy, consistent with experimental observations. For plasmas where the edge density is controlled using deuterium gas puffs, the effect of the RMP on ion thermal confinement is significantly reduced. Work supported by US DOE Grant DE-FC02-04ER54698 and DE-AC02-09CH11466.
Overview of Recent DIII-D Experimental Results
NASA Astrophysics Data System (ADS)
Fenstermacher, Max
2015-11-01
Recent DIII-D experiments have added to the ITER physics basis and to physics understanding for extrapolation to future devices. ELMs were suppressed by RMPs in He plasmas consistent with ITER non-nuclear phase conditions, and in steady state hybrid plasmas. Characteristics of the EHO during both standard high torque, and low torque enhanced pedestal QH-mode with edge broadband fluctuations were measured, including edge localized density fluctuations with a microwave imaging reflectometer. The path to Super H-mode was verified at high beta with a QH-mode edge, and in plasmas with ELMs triggered by Li granules. ITER acceptable TQ mitigation was obtained with low Ne fraction Shattered Pellet Injection. Divertor ne and Te data from Thomson Scattering confirm predicted drift-driven asymmetries in electron pressure, and X-divertor heat flux reduction and detachment were characterized. The crucial mechanisms for ExB shear control of turbulence were clarified. In collaboration with EAST, high beta-p scenarios were obtained with 80 % bootstrap fraction, high H-factor and stability limits, and large radius ITBs leading to low AE activity. Work supported by the US Department of Energy under DE-FC02-04ER54698 and DE-AC52-07NA27344.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekedahl, Annika, E-mail: annika.ekedahl@cea.fr; Bourdelle, Clarisse; Artaud, Jean-François
The longstanding expertise of the Tore Supra team in long pulse heating and current drive with radiofrequency (RF) systems will now be exploited in the WEST device (tungsten-W Environment in Steady-state Tokamak) [1]. WEST will allow an integrated long pulse tokamak programme for testing W-divertor components at ITER-relevant heat flux (10-20 MW/m{sup 2}), while treating crucial aspects for ITER-operation, such as avoidance of W-accumulation in long discharges, monitoring and control of heat fluxes on the metallic plasma facing components (PFCs) and coupling of RF waves in H-mode plasmas. Scenario modelling using the METIS-code shows that ITER-relevant heat fluxes are compatiblemore » with the sustainment of long pulse H-mode discharges, at high power (up to 15 MW / 30 s at I{sub P} = 0.8 MA) or high fluence (up to 10 MW / 1000 s at I{sub P} = 0.6 MA) [2], all based on RF heating and current drive using Ion Cyclotron Resonance Heating (ICRH) and Lower Hybrid Current Drive (LHCD). This paper gives a description of the ICRH and LHCD systems in WEST, together with the modelling of the power deposition of the RF waves in the WEST-scenarios.« less
Pilot tests of automated speed enforcement devices and procedures
DOT National Transportation Integrated Search
1984-02-01
This report concerns the identification of technologies applicable to speed enforcement and an assessment of their potential utility in the United States. The study emphasizes technologies in common use in Europe and elsewhere, but relatively unknown...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, D.P.
The process analyzed involves non-production, laboratory environment use of trichloroethylene for the cleaning of semiconductor devices. The option selection centered on the replacement of the trichloroethylene with a non-hazardous material. This process waste assessment was performed as part of a pilot project.
Designing and testing a tool for evaluating electronic flight bags
DOT National Transportation Integrated Search
2004-09-29
The Federal Aviation Administration (FAA), system designers, and customers all recognize that Electronic Flight Bags (EFBs) are sophisticated devices whose use could affect pilot performance. As a result, human factors issues have received considerab...
Towards Single-Step Biofabrication of Organs on a Chip via 3D Printing.
Knowlton, Stephanie; Yenilmez, Bekir; Tasoglu, Savas
2016-09-01
Organ-on-a-chip engineering employs microfabrication of living tissues within microscale fluid channels to create constructs that closely mimic human organs. With the advent of 3D printing, we predict that single-step fabrication of these devices will enable rapid design and cost-effective iterations in the development stage, facilitating rapid innovation in this field. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunt, T.; Sjostrom, S.; Smith, J.
1996-11-06
The overall objective of this two phase program is to investigate the use of dry carbon-based sorbents for mercury control. This information is important to the utility industry in anticipation of pending regulations. During Phase I, a bench-scale field test device that can be configured as an electrostatic precipitator, a pulse-jet baghouse, or a reverse-gas baghouse has been designed, built and integrated with an existing pilot-scale facility at PSCo`s Comanche Station. Up to three candidate sorbents will be injected into the flue gas stream upstream of the test device to and mercury concentration measurements will be made to determine themore » mercury removal efficiency for each sorbent. During the Phase II effort, component integration for the most promising dry sorbent technology shall be tested at the 5000 acfm pilot-scale.« less
Pilot Project for Spaceborne Massive Optical Storage Devices
NASA Technical Reports Server (NTRS)
Chen, Y. J.
1996-01-01
A space bound storage device has many special requirements. In addition to large storage capacity, fas read/ write time, and high reliability, it also needs to have small volume, light weight, low power consumption, radiation hardening, ability to operate in extreme temperature ranges, etc. Holographic optical recording technology, which has been making major advancements in recent years, is an extremely promising candidate. The goal of this pilot project is to demonstrate a laboratory bench-top holographic optical recording storage system (HORSS) based on nonlinear polymer films 1 and/or other advanced photo-refractive materials. This system will be used as a research vehicle to study relevant optical properties of novel holographic optical materials, to explore massive optical storage technologies based on the photo-refractive effect and to evaluate the feasibility of developing a massive storage system, based on holographic optical recording technology, for a space bound experiment in the near future.
Modeling activities on the negative-ion-based Neutral Beam Injectors of the Large Helical Device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agostinetti, P.; Antoni, V.; Chitarin, G.
2011-09-26
At the National Institute for Fusion Science (NIFS) large-scaled negative ion sources have been widely used for the Neutral Beam Injectors (NBIs) mounted on the Large Helical Device (LHD), which is the world-largest superconducting helical system. These injectors have achieved outstanding performances in terms of beam energy, negative-ion current and optics, and represent a reference for the development of heating and current drive NBIs for ITER.In the framework of the support activities for the ITER NBIs, the PRIMA test facility, which includes a RF-drive ion source with 100 keV accelerator (SPIDER) and a complete 1 MeV Neutral Beam system (MITICA)more » is under construction at Consorzio RFX in Padova.An experimental validation of the codes has been undertaken in order to prove the accuracy of the simulations and the soundness of the SPIDER and MITICA design. To this purpose, the whole set of codes have been applied to the LHD NBIs in a joint activity between Consorzio RFX and NIFS, with the goal of comparing and benchmarking the codes with the experimental data. A description of these modeling activities and a discussion of the main results obtained are reported in this paper.« less
Item generation and pilot testing of the Comprehensive Professional Behaviours Development Log.
Bartlett, Doreen J; Lucy, S Deborah; Bisbee, Leslie
2006-01-01
The purpose of this project was to generate and refine criteria for professional behaviors previously identified to be important for physical therapy practice and to develop and pilot test a new instrument, which we have called the Comprehensive Professional Behaviours Development Log (CPBDL). Items were generated from our previous work, the work of Warren May and his colleagues, a competency profile for entry-level physical therapists, our regulatory code of ethics, and an evaluation of clinical performance. A group of eight people, including recent graduates, clinical instructors and professional practice leaders, and faculty members, refined the items in two iterations using the Delphi process. The CPBDL contains nine key professional behaviors with a range of nine to 23 specific behavioral criteria for individuals to reflect on and to indicate the consistency of performance from a selection of "not at all," "sometimes," and "always" response options. Pilot testing with a group of 42 students in the final year of our entry-to-practice curriculum indicated that the criteria were clear, the measure was feasible to complete in a reasonable time frame, and there were no ceiling or floor effects. We believe that others, including health care educators and practicing professionals, might be interested in adapting the CPBDL in their own settings to enhance the professional behaviors of either students in preparation for entry to practice or clinicians wishing to demonstrate continuing competency to professional regulatory bodies.
Humphries, Debbie L; Carroll-Scott, Amy; Mitchell, Leif; Tian, Terry; Choudhury, Shonali; Fiellin, David A
2014-01-01
Although awareness of the importance of the research capacity of community-based organizations (CBOs) is growing, a uniform framework of the research capacity domains within CBOs has not yet been developed. To develop a framework and instrument (the Community REsearch Activity assessment Tool [CREAT]) for assessing the research activity and capacity of CBOs that incorporates awareness of the different data collection and analysis priorities of CBOs. We conducted a review of existing tools for assessing research capacity to identify key capacity domains. Instrument items were developed through an iterative process with CBO representatives and community researchers. The CREAT was then pilot tested with 30 CBOs. The four primary domains of the CREAT framework include 1) organizational support for research, 2) generalizable experiences, 3) research specific experiences, and 4) funding. Organizations reported a high prevalence of activities in the research-specific experiences domain, including conducting literature reviews (70%), use of research terminology (83%), and primary data collection (100%). Respondents see research findings as important to improve program and service delivery, and to seek funds for new programs and services. Funders, board members, and policymakers are the most important dissemination audiences. The work reported herein advances the field of CBO research capacity by developing a systematic framework for assessing research activity and capacity relevant to the work of CBOs, and by developing and piloting an instrument to assess activity in these domains.
Reinforcement Learning with Autonomous Small Unmanned Aerial Vehicles in Cluttered Environments
NASA Technical Reports Server (NTRS)
Tran, Loc; Cross, Charles; Montague, Gilbert; Motter, Mark; Neilan, James; Qualls, Garry; Rothhaar, Paul; Trujillo, Anna; Allen, B. Danette
2015-01-01
We present ongoing work in the Autonomy Incubator at NASA Langley Research Center (LaRC) exploring the efficacy of a data set aggregation approach to reinforcement learning for small unmanned aerial vehicle (sUAV) flight in dense and cluttered environments with reactive obstacle avoidance. The goal is to learn an autonomous flight model using training experiences from a human piloting a sUAV around static obstacles. The training approach uses video data from a forward-facing camera that records the human pilot's flight. Various computer vision based features are extracted from the video relating to edge and gradient information. The recorded human-controlled inputs are used to train an autonomous control model that correlates the extracted feature vector to a yaw command. As part of the reinforcement learning approach, the autonomous control model is iteratively updated with feedback from a human agent who corrects undesired model output. This data driven approach to autonomous obstacle avoidance is explored for simulated forest environments furthering autonomous flight under the tree canopy research. This enables flight in previously inaccessible environments which are of interest to NASA researchers in Earth and Atmospheric sciences.
The effects of workload on respiratory variables in simulated flight: a preliminary study.
Karavidas, Maria Katsamanis; Lehrer, Paul M; Lu, Shou-En; Vaschillo, Evgeny; Vaschillo, Bronya; Cheng, Andrew
2010-04-01
In this pilot study, we investigated respiratory activity and end-tidal carbon dioxide (P(et)CO(2)) during exposure to varying levels of work load in a simulated flight environment. Seven pilots (age: 34-60) participated in a one-session test on the Boeing 737-800 simulator. Physiological data were collected while pilots wore an ambulatory multi-channel recording device. Respiratory variables, including inductance plethysmography (respiratory pattern) and pressure of end-tidal carbon dioxide (P(et)CO(2)), were collected demonstrating change in CO(2) levels proportional to changes in flight task workload. Pilots performed a set of simulation flight tasks. Pilot performance was rated for each task by a test pilot; and self-report of workload was taken using the NASA-TLX scale. Mixed model analysis revealed that respiration rate and minute ventilation are significantly associated with workload levels and evaluator scores controlling for "vanilla baseline" condition. Hypocapnia exclusively occurred in tasks where pilots performed more poorly. This study was designed as a preliminary investigation in order to develop a psychophysiological assessment methodology, rather than to offer conclusive findings. The results show that the respiratory system is very reactive to high workload conditions in aviation and suggest that hypocapnia may pose a flight safety risk under some circumstances. Copyright © 2010 Elsevier B.V. All rights reserved.
Multi-megawatt, gigajoule plasma operation in Tore Supra
NASA Astrophysics Data System (ADS)
Dumont, R. J.; Goniche, M.; Ekedahl, A.; Saoutic, B.; Artaud, J.-F.; Basiuk, V.; Bourdelle, C.; Corre, Y.; Decker, J.; Elbèze, D.; Giruzzi, G.; Hoang, G.-T.; Imbeaux, F.; Joffrin, E.; Litaudon, X.; Lotte, Ph; Maget, P.; Mazon, D.; Nilsson, E.; The Tore Supra Team
2014-07-01
Integrating several important technological elements required for long pulse operation in magnetic fusion devices, the Tore Supra tokamak routinely addresses the physics and technology issues related to this endeavor and, as a result, contributes essential information on critical issues for ITER. During the last experimental campaign, components of the radiofrequency system including an ITER relevant launcher (passive active multijunction (PAM)) and continuous wave/3.7 GHz klystrons, have been extensively qualified, and then used to develop steady state scenarios in which the lower hybrid (LH), ion cyclotron (IC) and electron cyclotron (EC) systems have been combined in fully stationary shots (duration ˜150 s, injected power up to ˜8 MW, injected/extracted energy up to ˜1 GJ). Injection of LH power in the 5.0-6.0 MW range has extended the domain of accessible plasma parameters to higher densities and non-inductive currents. These discharges exhibit steady electron internal transport barriers (ITBs). We report here on various issues relevant to the steady state operation of future devices, ranging from operational aspects and limitations related to the achievement of long pulses in a fully actively cooled fusion device (e.g. overheating due to fast particle losses), to more fundamental plasma physics topics. The latter include a beneficial influence of IC resonance heating on the magnetohydrodynamic (MHD) stability in these discharges, which has been studied in detail. Another interesting observation is the appearance of oscillations of the central temperature with typical periods of the order of one to several seconds, caused by a nonlinear interplay between LH deposition, MHD activity and bootstrap current in the presence of an ITB.
NASA Astrophysics Data System (ADS)
Nocente, M.; Tardocchi, M.; Barnsley, R.; Bertalot, L.; Brichard, B.; Croci, G.; Brolatti, G.; Di Pace, L.; Fernandes, A.; Giacomelli, L.; Lengar, I.; Moszynski, M.; Krasilnikov, V.; Muraro, A.; Pereira, R. C.; Perelli Cippo, E.; Rigamonti, D.; Rebai, M.; Rzadkiewicz, J.; Salewski, M.; Santosh, P.; Sousa, J.; Zychor, I.; Gorini, G.
2017-07-01
We here present the principles and main physics capabilities behind the design of the radial gamma ray spectrometers (RGRS) system for alpha particle and runaway electron measurements at ITER. The diagnostic benefits from recent advances in gamma-ray spectrometry for tokamak plasmas and combines space and high energy resolution in a single device. The RGRS system as designed can provide information on α ~ particles on a time scale of 1/10 of the slowing down time for the ITER 500 MW full power DT scenario. Spectral observations of the 3.21 and 4.44 MeV peaks from the 9\\text{Be}≤ft(α,nγ \\right){{}12}\\text{C} reaction make the measurements sensitive to α ~ particles at characteristic resonant energies and to possible anisotropies of their slowing down distribution function. An independent assessment of the neutron rate by gamma-ray emission is also feasible. In case of runaway electrons born in disruptions with a typical duration of 100 ms, a time resolution of at least 10 ms for runaway electron studies can be achieved depending on the scenario and down to a current of 40 kA by use of external gas injection. We find that the bremsstrahlung spectrum in the MeV range from confined runaways is sensitive to the electron velocity space up to E≈ 30 -40 MeV, which allows for measurements of the energy distribution of the runaway electrons at ITER.
Impact of physics and technology innovations on compact tokamak fusion pilot plants
NASA Astrophysics Data System (ADS)
Menard, Jonathan
2016-10-01
For magnetic fusion to be economically attractive and have near-term impact on the world energy scene it is important to focus on key physics and technology innovations that could enable net electricity production at reduced size and cost. The tokamak is presently closest to achieving the fusion conditions necessary for net electricity at acceptable device size, although sustaining high-performance scenarios free of disruptions remains a significant challenge for the tokamak approach. Previous pilot plant studies have shown that electricity gain is proportional to the product of the fusion gain, blanket thermal conversion efficiency, and auxiliary heating wall-plug efficiency. In this work, the impact of several innovations is assessed with respect to maximizing fusion gain. At fixed bootstrap current fraction, fusion gain varies approximately as the square of the confinement multiplier, normalized beta, and major radius, and varies as the toroidal field and elongation both to the third power. For example, REBCO high-temperature superconductors (HTS) offer the potential to operate at much higher toroidal field than present fusion magnets, but HTS cables are also beginning to access winding pack current densities up to an order of magnitude higher than present technology, and smaller HTS TF magnet sizes make low-aspect-ratio HTS tokamaks potentially attractive by leveraging naturally higher normalized beta and elongation. Further, advances in kinetic stabilization and feedback control of resistive wall modes could also enable significant increases in normalized beta and fusion gain. Significant reductions in pilot plant size will also likely require increased plasma energy confinement, and control of turbulence and/or low edge recycling (for example using lithium walls) would have major impact on fusion gain. Reduced device size could also exacerbate divertor heat loads, and the impact of novel divertor solutions on pilot plant configurations is addressed. For missions including tritium breeding, high-thermal-efficiency liquid metal breeding blankets are attractive, and novel immersion blankets offer the potential for simplified fabrication and maintenance and reduced cost. Lastly, the optimal aspect ratio for a tokamak pilot plant is likely a function of the device mission and associated cost, with low aspect ratio favored for minimizing TF magnet mass and higher aspect ratio favored for minimizing blanket mass. The interplay between a range of physics and technology innovations for enabling compact pilot plants will be described. This work was supported by U.S. DOE Contract Number DE-AC02-09CH11466.
ERIC Educational Resources Information Center
Galuszka, Peter
2005-01-01
Using mobile digital devices--iPods, personal digital assistants (PDAs), Tablet PCs or advanced cell phones--is becoming a big campus trend. Their advantages include convenience and the ability to hear lectures or course-related music just about anywhere. PDA's such as Palm Pilots and BlackBerrys, iPods such as Apple's and Tablet PCs, including…
CFD Analysis of a T-38 Wing Fence
2007-06-01
or making major adjustments to the existing airframe. The answer lies in flow control. Flow control devices like vortex generators, winglets , and wing...proposed by the Air Force Test Pilot School. The driving force for considering a wing fence as opposed to vane vortex generators or winglets 3 was a row of...devices are vortex generators, fences, high lift flaps, and winglets . Active flow control injects the boundary layer with energy from small jets of
Dust remobilization tests in DIII-D divertor
NASA Astrophysics Data System (ADS)
Bykov, I.; Rudakov, D.; Moyer, R.; Ratynskaia, S.; Tolias, P.; Deangeli, M.; McLean, A.; Bystrov, K.
2015-11-01
Accumulation of dust on hot surfaces is a safety concern for ITER operation. We studied the life cycle of pre-deposited dust under ITER-relevant conditions by exposing W samples with W, C and Al (surrogate for Be) dust at the outer strike point (OSP) in a few ELMy H-mode discharges using DiMES. The maxima in the dust ejection rate correspond to ELM crashes under both attached and detached OSP conditions, as confirmed by a fast camera monitoring DiMES. SEM mapping of dust before and after exposures shows that >95 % of C and <5 % of metal dust gets remobilized in a few shots. In discharges with detached OSP, remaining Al particles melt and fuse together, forming larger spherical grains. At elevated heat flux with attached OSP, they melt, destruct and fuse with W substrate, which is not thermally affected. In this mode W grains partly melt and adjacent particles can weld together, forming larger asymmetric agglomerates with increased adhesion to the surface. We show that these results are consistent with recent observations from Pilot-PSI. Work supported by the US DOE under DE-FC02-04ER54698, DE-FG02-07ER54917 and DE-AC52-07NA27344.
M6-C artificial disc placement.
Coric, Domagoj; Parish, John; Boltes, Margaret O
2017-01-01
There has been a steady evolution of cervical total disc replacement (TDR) devices over the last decade resulting in surgical technique that closely mimics anterior cervical discectomy and fusion as well as disc design that emphasizes quality of motion. The M6-C TDR device is a modern-generation artificial disc composed of titanium endplates with tri-keel fixation as well as a polyethylene weave with a polyurethane core. Although not yet approved by the FDA, M6-C has finished a pilot and pivotal US Investigational Device Exemption (IDE) study. The authors present the surgical technique for implantation of a 2-level M6-C cervical TDR device. The video can be found here: https://youtu.be/rFEAqINLRCo .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Thomas
The design features developed for the Spherical Tokamak (ST) in the PPPL pilot plant study was used as the starting point in developing designs to meet the mission of a Fusion Nuclear Science Facility (FNSF) considering a range of machine sizes based on the influence of tritium consumption and maintenance strategies. The compact nature of a steady state operated ST device for this mission pushes operating conditions and places challenges in the design of components, device maintenance and the integration of supports and services. This paper reviews the general arrangement, design details and maintenance strategy of the ST-FNSF device coremore » for a 1.6-m and 1.0-m device; operating points which bracket the region between purchasing and breeding tritium.« less
A Thermal and Electrical Analysis of Power Semiconductor Devices
NASA Technical Reports Server (NTRS)
Vafai, Kambiz
1997-01-01
The state-of-art power semiconductor devices require a thorough understanding of the thermal behavior for these devices. Traditional thermal analysis have (1) failed to account for the thermo-electrical interaction which is significant for power semiconductor devices operating at high temperature, and (2) failed to account for the thermal interactions among all the levels involved in, from the entire device to the gate micro-structure. Furthermore there is a lack of quantitative studies of the thermal breakdown phenomenon which is one of the major failure mechanisms for power electronics. This research work is directed towards addressing. Using a coupled thermal and electrical simulation, in which the drift-diffusion equations for the semiconductor and the energy equation for temperature are solved simultaneously, the thermo-electrical interactions at the micron scale of various junction structures are thoroughly investigated. The optimization of gate structure designs and doping designs is then addressed. An iterative numerical procedure which incorporates the thermal analysis at the device, chip and junction levels of the power device is proposed for the first time and utilized in a BJT power semiconductor device. In this procedure, interactions of different levels are fully considered. The thermal stability issue is studied both analytically and numerically in this research work in order to understand the mechanism for thermal breakdown.
Design of a Rail Gun System for Mitigating Disruptions in Fusion Reactors
NASA Astrophysics Data System (ADS)
Lay, Wei-Siang
Magnetic fusion devices, such as the tokamak, that carry a large amount of current to generate the plasma confining magnetic fields have the potential to lose magnetic stability control. This can lead to a major plasma disruption, which can cause most of the stored plasma energy to be lost to localized regions on the walls, causing severe damage. This is the most important issue for the $20B ITER device (International Thermonuclear Experimental Reactor) that is under construction in France. By injecting radiative materials deep into the plasma, the plasma energy could be dispersed more evenly on the vessel surface thus mitigating the harmful consequences of a disruption. Methods currently planned for ITER rely on the slow expansion of gases to propel the radiative payloads, and they also need to be located far away from the reactor vessel, which further slows down the response time of the system. Rail guns are being developed for aerospace applications, such as for mass transfer from the surface of the moon and asteroids to low earth orbit. A miniatured version of this aerospace technology seems to be particularly well suited to meet the fast time response needs of an ITER disruption mitigation system. Mounting this device close to the reactor vessel is also possible, which substantially increases its performance because the stray magnetic fields near the vessel walls could be used to augment the rail gun generated magnetic fields. In this thesis, the potential viability on Rail Gun based DMS is studied to investigate its projected fast time response capability by design, fabrication, and experiment of an NSTX-U sized rail gun system. Material and geometry based tests are used to find the most suitable armature design for this system for which the desirable attributes are high specific stiffness and high electrical conductivity. With the best material in these studies being aluminum 7075, the experimental Electromagnetic Particle Injector (EPI) system has propelled an aluminum armature (weighing 3g) to a velocity more than 150 m/s within two milliseconds post trigger, consistent with the predicted projection for a system with those parameters. Fixed magnetic field probes and high-speed images capture the velocity profile. To propel the armatures, a 20 mF capacitor bank charged to 2 kV and augmented with external field coils powers the rails. These studies indicate that an EPI based system can indeed operate with a fast response time of less than three milliseconds after an impending disruption is detected, and thus warrants further studies to more fully develop the concept as a back-up option for an ITER DMS.
FDM study of ion exchange diffusion equation in glass
NASA Astrophysics Data System (ADS)
Zhou, Zigang; Yang, Yongjia; Wang, Qiang; Sun, Guangchun
2009-05-01
Ion-exchange technique in glass was developed to fabricate gradient refractive index optical devices. In this paper, the Finite Difference Method(FDM), which is used for the solution of ion-diffusion equation, is reported. This method transforms continual diffusion equation to separate difference equation. It unitizes the matrix of MATLAB program to solve the iteration process. The collation results under square boundary condition show that it gets a more accurate numerical solution. Compared to experiment data, the relative error is less than 0.2%. Furthermore, it has simply operation and kinds of output solutions. This method can provide better results for border-proliferation of the hexagonal and the channel devices too.
Milton, Alyssa; Lloyd-Evans, Brynmor; Fullarton, Kate; Morant, Nicola; Paterson, Bethan; Hindle, David; Kelly, Kathleen; Mason, Oliver; Lambert, Marissa; Johnson, Sonia
2017-11-09
A documented gap in support exists for service users following discharge from acute mental health services, and structured interventions to reduce relapse are rarely provided. Peer-facilitated self-management interventions have potential to meet this need, but evidence for their effectiveness is limited. This paper describes the development of a peer-provided self-management intervention for mental health service users following discharge from crisis resolution teams (CRTs). A five-stage iterative mixed-methods approach of sequential data collection and intervention development was adopted, following the development and piloting stages of the MRC framework for developing and evaluating complex interventions. Evidence review (stage 1) included systematic reviews of both peer support and self-management literature. Interviews with CRT service users (n = 41) regarding needs and priorities for support following CRT discharge were conducted (stage 2). Focus group consultations (n = 12) were held with CRT service-users, staff and carers to assess the acceptability and feasibility of a proposed intervention, and to refine intervention organisation and content (stage 3). Qualitative evaluation of a refined, peer-provided, self-management intervention involved qualitative interviews with CRT service user participants (n = 9; n = 18) in feasibility testing (stage 4) and a pilot trial (stage 5), and a focus group at each stage with the peer worker providers (n = 4). Existing evidence suggests self-management interventions can reduce relapse and improve recovery. Initial interviews and focus groups indicated support for the overall purpose and planned content of a recovery-focused self-management intervention for people leaving CRT care adapted from an existing resource: The personal recovery plan (developed by Repper and Perkins), and for peer support workers (PSWs) as providers. Participant feedback after feasibility testing was positive regarding facilitation of the intervention by PSWs; however, the structured self-management booklet was underutilised. Modifications to the self-management intervention manual and PSWs' training were made before piloting, which confirmed the acceptability and feasibility of the intervention for testing in a future, definitive trial. A manualised intervention and operating procedures, focusing on the needs and priorities of the target client group, have been developed through iterative stages of intervention development and feedback for testing in a trial context. Trial Registration ISRCTN01027104 date of registration: 11/10/2012.
LeVasseur, Sandra A; Li, Dongmei
2013-01-01
Background The use of personal communication devices (such as basic cell phones, enhanced cell phones or smartphones, and tablet computers) in hospital units has risen dramatically in recent years. The use of these devices for personal and professional activities can be beneficial, but also has the potential to negatively affect patient care, as clinicians may become distracted by these devices. Objective No validated questionnaire examining the impact of the use of these devices on patient care exists; thus, we aim to develop and validate an online questionnaire for surveying the views of registered nurses with experience of working in hospitals regarding the impact of the use of personal communication devices on hospital units. Methods A 50-item, four-domain questionnaire on the views of registered nursing staff regarding the impact of personal communication devices on hospital units was developed based on a literature review and interviews with such nurses. A repeated measures pilot study was conducted to examine the psychometrics of a survey questionnaire and the feasibility of conducting a larger study. Psychometric testing of the questionnaire included examining internal consistency reliability and test-retest reliability in a sample of 50 registered nurses. Results The response rate for the repeated measures was 30%. Cronbach coefficient alpha was used to examine the internal consistency and reliability, and in three of the four question groups (utilization, impact, and opinions), the correlation was observed to be very high. This suggests that the questions were measuring a single underlying theme. The Cronbach alpha value for the questions in the performance group, describing the use of personal communication devices while working, was lower than those for the other question groups. These values may be an indication that the assumptions underlying the Cronbach alpha calculation may have been violated for this group of questions. A Spearman rho correlation was used to determine the test-retest reliability. There was a strong test-retest reliability between the two tests for the majority of the questions. The average test-retest percent of agreement for the Likert scale responses was 74% (range 43-100%). Accounting for responses within the 1 SD range on the Likert scale increased the agreement to 96% (range 87-100%). Missing data were in the range of 0 to 7%. Conclusions The psychometrics of the questionnaire showed good to fair levels of internal consistency and test-retest reliability. The pilot study demonstrated that our questionnaire may be useful in exploring registered nurses’ perceptions of the impact of personal electronic devices on hospital units in a larger study. PMID:24280660
Gupta, Rajesh; Patel, Rajan; Murty, Naganand; Panicker, Rahul; Chen, Jane
2015-02-01
Relative to drugs, diagnostics, and vaccines, efforts to develop other global health technologies, such as medical devices, are limited and often focus on the short-term goal of prototype development instead of the long-term goal of a sustainable business model. To develop a medical device to address neonatal hypothermia for use in resource-limited settings, we turned to principles of design theory: (1) define the problem with consideration of appropriate integration into relevant health policies, (2) identify the users of the technology and the scenarios in which the technology would be used, and (3) use a highly iterative product design and development process that incorporates the perspective of the user of the technology at the outset and addresses scalability. In contrast to our initial idea, to create a single device, the process guided us to create two separate devices, both strikingly different from current solutions. We offer insights from our initial experience that may be helpful to others engaging in global health technology development.
Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.
Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana
2018-04-01
The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.
Recent Advances in Transcatheter Aortic Valve Implantation: Novel Devices and Potential Shortcomings
Blumenstein, J.; Liebetrau, C.; Linden, A. Van; Moellmann, H.; Walther, T.; Kempfert, J.
2013-01-01
During the past years transcatheter aortic valve implantation (TAVI) has evolved to a standard technique for the treatment of high risk patients suffering from severe aortic stenosis. Worldwide the number of TAVI procedures is increasing exponentially. In this context both the transapical antegrade (TA) and the transfemoral retrograde (TF) approach are predominantly used and can be considered as safe and reproducible access sites for TAVI interventions. As a new technology TAVI is in a constant progress regarding the development of new devices. While in the first years only the Edwards SAPIEN™ and the Medtronic CoreValve™ prostheses were commercial available, recently additional devices obtained CE-mark approval and others have entered initial clinical trials. In addition to enhance the treatment options in general, the main driving factor to further develop new device iterations is to solve the drawbacks of the current TAVI systems: paravalvular leaks, occurrence of AV-blocks and the lack of full repositionability. PMID:24313644
Chung, Philip; Heller, J Alex; Etemadi, Mozziyar; Ottoson, Paige E; Liu, Jonathan A; Rand, Larry; Roy, Shuvo
2014-06-27
Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system. Low costs and rapid turnaround time in this technique lower the barrier to iteratively designing and prototyping complex elastomer devices. Furthermore, CAD models developed in this process can be later adapted for metal mold tooling design, enabling an easy transition to a traditional injection molding process. We have used this technique to manufacture intravaginal probes involving complex geometries, as well as overmolding over metal parts, using tools commonly available within an academic research laboratory. However, this technique can be easily adapted to create liquid injection molded devices for many other applications.
Cost-effective rapid prototyping and assembly of poly(methyl methacrylate) microfluidic devices.
Matellan, Carlos; Del Río Hernández, Armando E
2018-05-03
The difficulty in translating conventional microfluidics from laboratory prototypes to commercial products has shifted research efforts towards thermoplastic materials for their higher translational potential and amenability to industrial manufacturing. Here, we present an accessible method to fabricate and assemble polymethyl methacrylate (PMMA) microfluidic devices in a "mask-less" and cost-effective manner that can be applied to manufacture a wide range of designs due to its versatility. Laser micromachining offers high flexibility in channel dimensions and morphology by controlling the laser properties, while our two-step surface treatment based on exposure to acetone vapour and low-temperature annealing enables improvement of the surface quality without deformation of the device. Finally, we demonstrate a capillarity-driven adhesive delivery bonding method that can produce an effective seal between PMMA devices and a variety of substrates, including glass, silicon and LiNbO 3 . We illustrate the potential of this technique with two microfluidic devices, an H-filter and a droplet generator. The technique proposed here offers a low entry barrier for the rapid prototyping of thermoplastic microfluidics, enabling iterative design for laboratories without access to conventional microfabrication equipment.
Designing a tool to assess the usability of electronic flight bags (EFBs)
DOT National Transportation Integrated Search
2004-09-01
The Federal Aviation Administration (FAA), system designers, and customers all recognize that Electronic Flight Bags (EFBs) are sophisticated devices whose use could affect pilot performance. As a result, human factors issues have received considerab...
A Pilot/Vehicle Model Analysis of the Effects of Motion Cues on Harrier Control Tasks.
1983-09-01
7 D- R136 291 A PILOT/VEHILE MODEL ANALYSIS OF THE EFFECTS OF MOTION i/i LS 91 CUES ON HARRIER C..(U) BOLT BERANEK AND NEWMAN INC CAMBRIDGE MA S...provided by well-designed platform motion systems , the actual rovement of performance or training effectiveness that results from incorporating these...for the Harrier AV-8B. The effects of providing motion cues via an idealized platform motion system or a g-seat device are predicted with the model, and
NASA Technical Reports Server (NTRS)
Ashworth, B. R.; Hall, A. C.; Clark, C. E. (Inventor)
1981-01-01
A device for providing acceleration cues to the helmet of a simulator pilot is described. Pulleys are attached to both shoulders of the pilot. A cable is attached to both sides of the helmet and extends through the pulleys to a takeup reel that is controlled by a torque motor. Control signals are applied to a servo system including the torque motor, the takeup reel and a force transducer which supplies the feedback signal. In one embodiment of the invention the force transducer is in the cable and in another it is in the takeup reel.
Pilot production of 4 sq cm ITO/InP photovoltaic solar cells
NASA Technical Reports Server (NTRS)
Gessert, T. A.; Li, X.; Coutts, T. J.; Tzafaras, N.
1991-01-01
Experimental results of a pilot production of 32 4-sq cm indium tin oxide (ITO)InP space solar cells are presented. The discussion includes analysis of the device performance of the best cells produced as well as the performance range of all production cells. The experience gained from the production is discussed, indicating other issues that may be encountered when large-scale productions are initiated. Available data on a 4-sq cm ITO/InP cell that was flown on the UoSAT-5 satellite is reported.
Welch, Janet; Dowell, Shannon; Johnson, Cynthia S
2007-01-01
The feasibility of using an electronic device to self-monitor diet and fluid intake was assessed using the treatment implementation model. The three patients on hemodialysis who participated in this pilot study were asked to self-monitor diet and fluid intake for 12 weeks with a personal digital assistant. The intervention was delivered as intended; however, participants reported problems with usability, and compliance to self-monitoring was lower than desirable. Further adjustments to the intervention will be made before testing efficacy.
Building and testing a patient-centric electronic bedside communication center.
Dykes, Patricia C; Carroll, Diane L; Hurley, Ann C; Benoit, Angela; Chang, Frank; Pozzar, Rachel; Caligtan, Christine A
2013-01-01
In this article, the authors describe the development and pilot testing of an electronic bedside communication center (eBCC) prototype to improve access to health information for hospitalized adults and their family caregivers. Focus groups were used to identify improvements for the initial eBCC prototype developed by the research team. Face-to-face bedside interviews and questions were presented while patients used the eBCC for usability testing to drive further development. Qualitative methods within an iterative, participatory approach supported the development of an eBCC prototype that was considered both easy to use and helpful for accessing tailored patient information during an inpatient hospitalization to receive acute care. Copyright 2013, SLACK Incorporated.
An introduction to the new Productivity Information Management System (PIMS)
NASA Technical Reports Server (NTRS)
Hull, R.
1982-01-01
The productivity information management system (PIMS), is described. The main objective of this computerized system is to enable management scientists to interactively explore data concerning DSN operations, maintenance and repairs, to develop and verify models for management planning. The PIMS will provide a powerful set of tools for iteratively manipulating data sets in a wide variety of ways. The initial version of PIMS will be a small scale pilot system. The following topics are discussed: (1) the motivation for developing PIMS; (2) various data sets which will be integrated by PIMS; (3) overall design of PIMS; and (4) how PIMS will be used. A survey of relevant databases concerning DSN operations at Goldstone is also included.
Prioreschi, Alessandra; Nappey, Thomas; Westgate, Kate; Olivier, Patrick; Brage, Soren; Micklesfield, Lisa Kim
2018-01-01
It is important to be able to reliably and feasibly measure infant and toddler physical activity in order to determine adherence to current physical activity guidelines and effects on early life development, growth and health. This study aimed to describe the development of an infant wearable wrist-worn band for the measurement of physical activity; to determine the feasibility of the device data for observational measurement of physical activity and to determine the caregiver reported acceptability of the infant wearable wrist band. After various iterations of prototypes and piloting thereof, a final wearable band was designed to fit an Axivity AX3 monitor. Mother and infant/toddler (aged 3-24 months) pairs ( n = 152) were recruited, and mothers were asked for their child to wear the band with enclosed monitor at all times for 1 week (minimum 3 days). Feasibility was assessed by determining technical reliability of the data, as well as wear time and compliance according to requirements for observational measurement. Acceptability was assessed via questionnaire. Technical reliability of the Axivity AX3 monitors in this age group was good. After excluding days that did not have at least 15 h of wear time, only 2% of participants had less than three valid days of data remaining, and 4% of participants had no data (due to device loss or data loss). Therefore, 94% of participants were compliant, having three or more days of wear with at least 15 h of wear per day, thus providing enough valid data for observational measurement. The majority (60%) of mothers reported being "very happy" with the safety of the device, while only 8% were "a little worried". A large majority (86%) of mothers stated that the band attracted attention from others, although this was mostly attributed to curiosity about the function of the band. Most (80%) of participants rated the comfort of the band as "comfortable", and 10% rated it as "very comfortable". The infant wearable band proved to be feasible and acceptable according to the criteria tested, and compliance wearing the band was good. We have therefore provided a replicable, comfortable and acceptable wearable band for the measurement of infant and toddler physical activity.
Shields, Michael D.; ALQahtani, Fahad; Rivey, Michael P.
2018-01-01
We describe, for the first time, the use of a mobile device platform for remote direct observation of inhaler use and technique. The research programme commenced with a rapid systematic review of mobile device (or videophone) use for direct observation of therapy (MDOT). Ten studies (mainly pilots) were identified involving patients with tuberculosis, sickle cell disease and Alzheimer's disease. New studies are ongoing (ClinicalTrials.gov website) in TB, stroke, sickle cell disease, HIV and opioid dependence. Having identified no prior use of MDOT in inhaler monitoring, we implemented a feasibility study in 12 healthy volunteer children (2–12 years; 8 females and 4 males) over a period of 14 days, with twice daily video upload of their 'dummy' inhaler use. Two children uploaded 100% of the requested videos, with only one child having an inhaler upload rate of <75%. The quality of uploaded videos was generally good (only 1.7% of unacceptable quality for evaluation). The final aspect of the research was a pilot study using MDOT (6 weeks) in 22 children with difficult to treat asthma. Healthcare professionals evaluated inhaler technique using uploaded videos and provided telephone instruction on improving inhaler use. The main outcomes were assessed at week 12 post initiation of MDOT. By week 5, all children still engaging in MDOT (n = 18) were judged to have effective inhaler technique. Spirometry values did not vary to a significantly significant degree between baseline and 12 weeks (P>0.05), however, mean fraction of exhaled nitric oxide (FeNO) values normalised (mean 38.7 to 19.3ppm) and mean Asthma Control Test values improved (13.1 to mean 17.8). Feedback from participants was positive. Overall the findings open up a new paradigm in device independent (can be used for any type of inhaler device) monitoring, providing a platform for evaluating / improving inhaler use at home. PMID:29401500
Optimized up-down asymmetry to drive fast intrinsic rotation in tokamaks
NASA Astrophysics Data System (ADS)
Ball, Justin; Parra, Felix I.; Landreman, Matt; Barnes, Michael
2018-02-01
Breaking the up-down symmetry of the tokamak poloidal cross-section can significantly increase the spontaneous rotation due to turbulent momentum transport. In this work, we optimize the shape of flux surfaces with both tilted elongation and tilted triangularity in order to maximize this drive of intrinsic rotation. Nonlinear gyrokinetic simulations demonstrate that adding optimally-tilted triangularity can double the momentum transport of a tilted elliptical shape. This work indicates that tilting the elongation and triangularity in an ITER-like device can reduce the energy transport and drive intrinsic rotation with an Alfvén Mach number of roughly 1% . This rotation is four times larger than the rotation expected in ITER and is approximately what is needed to stabilize MHD instabilities. It is shown that this optimal shape can be created using the shaping coils of several present-day experiments.
[A peak recognition algorithm designed for chromatographic peaks of transformer oil].
Ou, Linjun; Cao, Jian
2014-09-01
In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.
High density operation for reactor-relevant power exhaust
NASA Astrophysics Data System (ADS)
Wischmeier, M.; ASDEX Upgrade Team; Jet Efda Contributors
2015-08-01
With increasing size of a tokamak device and associated fusion power gain an increasing power flux density towards the divertor needs to be handled. A solution for handling this power flux is crucial for a safe and economic operation. Using purely geometric arguments in an ITER-like divertor this power flux can be reduced by approximately a factor 100. Based on a conservative extrapolation of current technology for an integrated engineering approach to remove power deposited on plasma facing components a further reduction of the power flux density via volumetric processes in the plasma by up to a factor of 50 is required. Our current ability to interpret existing power exhaust scenarios using numerical transport codes is analyzed and an operational scenario as a potential solution for ITER like divertors under high density and highly radiating reactor-relevant conditions is presented. Alternative concepts for risk mitigation as well as strategies for moving forward are outlined.
NASA Technical Reports Server (NTRS)
Wheeler, Kevin; Jorgensen, Charles
2000-01-01
This paper presents recent results in neuroelectric pattern recognition of electromyographic (EMG) signals used to control virtual computer input devices. The devices are designed to substitute for the functions of both a traditional joystick and keyboard entry method. We demonstrate recognition accuracy through neuroelectric control of a 757 class simulation aircraft landing at San Francisco International Airport using a virtual joystick as shown. This is accomplished by a pilot closing his fist in empty air and performing control movements that are captured by a dry electrode array on the arm which are then analyzed and routed through a flight director permitting full pilot outer loop control of the simulation. We then demonstrate finer grain motor pattern recognition through a virtual keyboard by having a typist tap his traders on a typical desk in a touch typist position. The EMG signals are then translated to keyboard presses and displayed. The paper describes the bioelectric pattern recognition methodology common to both examples. Figure 2 depicts raw EMG data from typing, the numeral '8' and the numeral '9'. These two gestures are very close in appearance and statistical properties yet are distinguishable by our hidden Kharkov model algorithms. Extensions of this work to NASA emissions and robotic control are considered.
Older adults' attitudes towards and perceptions of "smart home" technologies: a pilot study.
Demiris, George; Rantz, Marilyn; Aud, Myra; Marek, Karen; Tyrer, Harry; Skubic, Marjorie; Hussam, Ali
2004-06-01
The study aim is to explore the perceptions and expectations of seniors in regard to "smart home" technology installed and operated in their homes with the purpose of improving their quality of life and/or monitoring their health status. Three focus group sessions were conducted within this pilot study to assess older adults' perceptions of the technology and ways they believe technology can improve their daily lives. Themes discussed in these groups included participants' perceptions of the usefulness of devices and sensors in health-related issues such as preventing or detecting falls, assisting with visual or hearing impairments, improving mobility, reducing isolation, managing medications, and monitoring of physiological parameters. The audiotapes were transcribed and a content analysis was performed. A total of 15 older adults participated in three focus group sessions. Areas where advanced technologies would benefit older adult residents included emergency help, prevention and detection of falls, monitoring of physiological parameters, etc. Concerns were expressed about the user-friendliness of the devices, lack of human response and the need for training tailored to older learners. All participants had an overall positive attitude towards devices and sensors that can be installed in their homes in order to enhance their lives.
Perimeter Security and Intruder Detection Using Gravity Gradiometry: A Feasibility Study
2011-03-24
design, build, and operate, and it is usually not feasible to integrate new technology into an already existing system. So far, however, the...gravitational gradients is not a new concept and has been applied across a variety of industries. The first device for gravity gradient measurement was the...which generates a new simulated GGI reading. The program loops for a set number of iterations, and then ends by calculating algorithm performance
Code of Federal Regulations, 2011 CFR
2011-07-01
... PILOT PROGRAM FOR TEMPORARY EXCHANGE OF INFORMATION TECHNOLOGY PERSONNEL § 241.2 Definitions. In this... organizational goals. Information technology (IT) as defined in section 11101 of title 40, U.S.C. includes computers, ancillary equipment (including imaging peripherals, input, output, and storage devices necessary...
GPS based pilot survey of freight movements in the Midwest region.
DOT National Transportation Integrated Search
2013-05-01
This report explains the methodology and results surrounding a recently completed study of a major grocery trucking firms travel patterns. The research group used Global Positioning System (GPS) logging devices to trace the temporal and spatial mo...
DOT National Transportation Integrated Search
2000-02-01
The rapid introduction of Global Positioning System (GPS) receivers for airborne navigation has outpaced the capacity of international aviation authorities to resolve human factors issues that concern safe and efficient use of such devices. Current c...
Review of safety reports involving electronic flight bags
DOT National Transportation Integrated Search
2009-04-27
Electronic Flight Bags (EFBs) are a relatively new device used by pilots. Even so, 37 safety-related events involving EFBs were identified from the public online Aviation Safety Reporting System (ASRS) database as of June 2008. In addition, two accid...
Topical oxygen therapy promotes the healing of chronic diabetic foot ulcers: a pilot study.
Hayes, P D; Alzuhir, N; Curran, G; Loftus, I M
2017-11-02
Interventions that can heal or reduce diabetic foot ulcer (DFU) size may reduce the incidence of infection and amputation, and reduce associated social and economic costs. Many chronic wounds exhibit a degree of hypoxia and this leads to a reduction in healing processes including cell division and differentiation, angiogenesis, infection prevention, and collagen production. The aim of this pilot study was to assess the effects of a device supplying continuous oxygen ambulatory therapy on healing in chronic DFUs. Patients with chronic DFUs from two tertiary referral hospitals in the UK received treatment with the device. Data were prospectively obtained on wound size using standardised digital images measured by a clinician blinded to the study. Data on device satisfaction and pain were also obtained. We recruited 10 patients, with a mean ulcer duration of 43 weeks (median: 43 weeks) before treatment. By week eight, mean ulcer size had decreased by 51% (median: 53%). Seven of the 10 ulcers were in a healing trajectory, one ulcer present for 56 weeks healed completely, a two-year old ulcer was reduced by more than 50%, and a third, present for 88 weeks, was down to 10% of its original size by the end of the eight-week study. There was also a non-significant trend towards reduction in pain and the device was extremely well tolerated. The ambulatory topical oxygen delivery device showed a significant beneficial effect on wound size. This poses practical advantages over currently existing oxygen-based wound therapies such as hyperbaric oxygen therapy due to its continuous oxygen delivery, ease of use, safety and lower cost. The results of this study warrant further review of the device in comparison to standard wound therapies.
Clinical Evaluation of a Safety-device to Prevent Urinary Catheter Inflation Related Injuries.
Davis, Niall F; Cunnane, Eoghan M; Mooney, Rory O'C; Forde, James C; Walsh, Michael T
2018-05-01
To evaluate the feasibility of a novel "safety-valve" device for preventing catheter related urethral trauma during urethral catheterization (UC). To assess the opinions of clinicians on the performance of the safety-valve device. A validated prototype "safety-valve" device for preventing catheter balloon inflation related urethral injuries was prospectively piloted in male patients requiring UC in a tertiary referral teaching hospital (n = 100). The device allows fluid in the catheter system to decant through an activated safety threshold pressure valve if the catheter anchoring balloon is misplaced. Users evaluated the "safety-valve" with an anonymous questionnaire. The primary outcome measurement was prevention of anchoring balloon inflation in the urethra. Secondary outcome measurement was successful inflation of urinary catheter anchoring balloon in the bladder. Patient age was 76 ± 12 years and American Society of Anaesthesiologists grade was 3 ± 1.4. The "safety-valve" was utilized by 34 clinicians and activated in 7% (n = 7/100) patients during attempted UC, indicating that the catheter anchoring balloon was incorrectly positioned in the patient's urethra. In these 7 cases, the catheter was successfully manipulated into the urinary bladder and inflated. 31 of 34 (91%) clinicians completed the questionnaire. Ten percent (n = 3/31) of respondents had previously inflated a urinary catheter anchoring balloon in the urethra and 100% (n = 31) felt that a safety mechanism for preventing balloon inflation in the urethra should be compulsory for all UCs. The safety-valve device piloted in this clinical study offers an effective solution for preventing catheter balloon inflation related urethral injuries. Copyright © 2018 Elsevier Inc. All rights reserved.
Browne, Jacinta E; Cannon, Louise M; McDermott, Ronan; Ryan, Max; Fagan, Andrew J
2017-11-01
A device for the training and quantitative assessment of the competency of trainee radiologists in the technically challenging area of breast sonography was developed and evaluated. Currently, suitable commercially available devices are lacking, and there is a growing realization that the reliance on direct exposure to patients for learning may not represent best practice from either the trainees' or patients' perspective. Three devices (PI, PII and PIII) were designed to produce very realistic sonographic images of breast morphology with a range of embedded pathologies. The pilot evaluation used a case study research design to evaluate the role of the anthropomorphic breast sonography training device in training and assessment in a clinical environment. Through the case study, it was possible to evaluate the process and relationships when using this type of training intervention for a small group of radiology resident trainees. The investigation involved a baseline assessment of trainees' (n = 4) ability to detect and characterize all lesions in PI, followed by a 4-wk training period on PII and a post-training assessment using PIII. The evaluation revealed an improvement of 30% ± 8% in the trainee's performance from pre- to post-training. It was expected that the performance of the trainees would improve as the training phantom described in this study aligns with the learning theory of constructivism and fits the ideal specifications of a medical training device in terms of its realism and facilitation of self-directed learning and deliberate practice of the trainees. The device provides a useful platform upon which training and assessment can be facilitated. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Stability Formulation for Integrated Opto-mechanic Phase Shifters.
Ozer, Yigit; Kocaman, Serdar
2018-01-31
Stability of opto-mechanical phase shifters consisting of waveguides and non-signal carrying control beams is investigated thoroughly and a formula determining the physical limitations has been proposed. Suggested formulation is not only beneficial to determine physical strength of the system but also advantageous to guess the response of the output to the fabrication errors. In the iterative analysis of cantilever and double-clamped beam geometrical configurations, the stability condition is revealed under the strong inter-dependence of the system parameters such as input power, device length and waveguide separation. Numerical calculations involving effective index modifications and opto-mechanic movements show that well-known cantilever beams are unstable and inadequate to generate φ = 180° phase difference, while double-clamped beam structures can be utilized to build functional devices. Ideal operation conditions are also presented in terms of both the device durability and the controllability of phase evolution.
Evolution of penile prosthetic devices
Burnett, Arthur L.
2015-01-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases. PMID:25763121
Evolution of penile prosthetic devices.
Le, Brian; Burnett, Arthur L
2015-03-01
Penile implant usage dates to the 16th century yet penile implants to treat erectile dysfunction did not occur until nearly four centuries later. The modern era of penile implants has progressed rapidly over the past 50 years as physicians' knowledge of effective materials for penile prostheses and surgical techniques has improved. Herein, we describe the history of penile prosthetics and the constant quest to improve the technology. Elements of the design from the first inflatable penile prosthesis by Scott and colleagues and the Small-Carrion malleable penile prosthesis are still found in present iterations of these devices. While there have been significant improvements in penile prosthesis design, the promise of an ideal prosthetic device remains elusive. As other erectile dysfunction therapies emerge, penile prostheses will have to continue to demonstrate a competitive advantage. A particular strength of penile prostheses is their efficacy regardless of etiology, thus allowing treatment of even the most refractory cases.
Cost-effectiveness of emergency contraception options over 1 year.
Bellows, Brandon K; Tak, Casey R; Sanders, Jessica N; Turok, David K; Schwarz, Eleanor B
2018-05-01
The copper intrauterine device is the most effective form of emergency contraception and can also provide long-term contraception. The levonorgestrel intrauterine device has also been studied in combination with oral levonorgestrel for women seeking emergency contraception. However, intrauterine devices have higher up-front costs than oral methods, such as ulipristal acetate and levonorgestrel. Health care payers and decision makers (eg, health care insurers, government programs) with financial constraints must determine if the increased effectiveness of intrauterine device emergency contraception methods are worth the additional costs. We sought to compare the cost-effectiveness of 4 emergency contraception strategies-ulipristal acetate, oral levonorgestrel, copper intrauterine device, and oral levonorgestrel plus same-day levonorgestrel intrauterine device-over 1 year from a US payer perspective. Costs (2017 US dollars) and pregnancies were estimated over 1 year using a Markov model of 1000 women seeking emergency contraception. Every 28-day cycle, the model estimated the predicted number of pregnancy outcomes (ie, live birth, ectopic pregnancy, spontaneous abortion, or induced abortion) resulting from emergency contraception failure and subsequent contraception use. Model inputs were derived from published literature and national sources. An emergency contraception strategy was considered cost-effective if the incremental cost-effectiveness ratio (ie, the cost to prevent 1 additional pregnancy) was less than the weighted average cost of pregnancy outcomes in the United States ($5167). The incremental cost-effectiveness ratios and probability of being the most cost-effective emergency contraception strategy were calculated from 1000 probabilistic model iterations. One-way sensitivity analyses were used to examine uncertainty in the cost of emergency contraception, subsequent contraception, and pregnancy outcomes as well as the model probabilities. In 1000 women seeking emergency contraception, the model estimated direct medical costs of $1,228,000 and 137 unintended pregnancies with ulipristal acetate, compared to $1,279,000 and 150 unintended pregnancies with oral levonorgestrel, $1,376,000 and 61 unintended pregnancies with copper intrauterine devices, and $1,558,000 and 63 unintended pregnancies with oral levonorgestrel plus same-day levonorgestrel intrauterine device. The copper intrauterine device was the most cost-effective emergency contraception strategy in the majority (63.9%) of model iterations and, compared to ulipristal acetate, cost $1957 per additional pregnancy prevented. Model estimates were most sensitive to changes in the cost of the copper intrauterine device (with higher copper intrauterine device costs, oral levonorgestrel plus same-day levonorgestrel intrauterine device became the most cost-effective option) and the cost of a live birth (with lower-cost births, ulipristal acetate became the most cost-effective option). When the proportion of obese women in the population increased, the copper intrauterine device became even more most cost-effective. Over 1 year, the copper intrauterine device is currently the most cost-effective emergency contraception option. Policy makers and health care insurance companies should consider the potential for long-term savings when women seeking emergency contraception can promptly obtain whatever contraceptive best meets their personal preferences and needs; this will require removing barriers and promoting access to intrauterine devices at emergency contraception visits. Copyright © 2018 Elsevier Inc. All rights reserved.
Chambers, James D; May, Katherine E; Neumann, Peter J
2013-06-01
The Food and Drug Administration (FDA) and Medicare use different standards to determine, first, whether a new drug or medical device can be marketed to the public and, second, if the federal health insurance program will pay for use of the drug or device. This discrepancy creates hurdles and uncertainty for drug and device manufacturers. We analyzed discrepancies between FDA approval and Medicare national coverage determinations for sixty-nine devices and Part B drugs approved during 1999-2011. We found that Medicare covered FDA-approved drugs or devices 80 percent of the time. However, Medicare often added conditions beyond FDA approval, particularly for devices and most often restricting coverage to patients with the most severe disease. In some instances, Medicare was less restrictive than the FDA. Our findings highlight the importance for drug and device makers of anticipating Medicare's needs when conducting clinical studies to support their products. Our findings also provide important insights for the FDA's and Medicare's pilot parallel review program.
Acceleration effects on neck muscle strength: pilots vs. non-pilots.
Seng, Kok-Yong; Lam, Pin-Min; Lee, Vee-Sin
2003-02-01
Conditioning of neck muscles, if any, due to repeated exposures to +Gz forces has received little research attention. This study was conducted to evaluate and compare the neck muscle strength of test volunteers representative of the general populations of fighter aircraft pilots and non-pilots. The tests were performed using a special attachment device on a computerized dynamometer. Ten pilots and ten non-pilots volunteered as test subjects. Each individual's maximal isometric neck muscle strength was evaluated in the extension, flexion, and left and right lateral bending directions in a single day. Peak values from the measurements were used for data analysis. Overall neck strength was calculated as the mean values for the four directions in each group. The overall muscular strength of the necks of pilots did not differ significantly from that of non-pilots, nor did exposure to +Gz forces lead to specific changes in isometric muscle strength across any of the four principal directions. Neck muscle strength in the four measured directions pooled across the two subgroups were statistically significant. The widespread practice of adopting protective head-positioning strategies to minimize neck strains, coupled with results from this research study, suggest that the neck muscles are subjected to reduced in-flight strengthening workouts during exposures to +Gz forces. To maximize in-flight performance and minimize +Gz-induced neck injuries, fighter pilots should be encouraged to perform on-land neck muscle strengthening exercise and in-flight head-positioning techniques. More research is needed to fine-tune this countermeasure strategy against cervical spine injury.
Colorimetric analysis of pigmented skin lesions: a pilot study with the Visi-Chroma VC-100 device.
Vereecken, P; Mommaerts, M; Duez, C; Petein, M; Laporte, M; Hubinon, J-L; Heenen, M
2006-01-01
Definition of the colour of pigmented skin lesions (PSLs) with the naked eye remains subjective and may be influenced by lighting. This problem underlines the usefulness of instrumental assessments such as epiluminescence microscopy and colorimetric devices. We describe here a new method of colour analysis of PSLs with the Visi-Chroma VC-100 device, which illuminates the surface of the skin with white light-emitting diodes (LEDs) and analyses the reflected light by a red-green-blue (RGB) charge-coupled device (CCD) colour camera. Twenty-one PSLs to be excised for cosmetic or medical reasons were analysed by this device with clinicopathological correlation. This method is feasible and might be useful to assess the colour of PSLs and allow comparisons for changes over time. Further studies are needed to determine the usefulness of this device in clinical practice.
Material selection for climbing hardware using the example of a belay device
NASA Astrophysics Data System (ADS)
Semenov, E.; Schwanitz, S.; Odenwald, S.
2017-03-01
The aim of the research project was to design a novel climbing belay device. The present article describes the details of the therefor performed material selection. Literature research on the materials used in commercially available belay devices revealed a lack of definite information. Thus, a pilot x-ray fluorescence (XRF) test was performed on a small sample of common aluminium belay devices. It revealed the use of a variety of different alloy systems. The selection process continued by compiling a thorough list of constraints and objectives for this safety related piece of sports equipment. Different material options including non-aluminium-materials were discussed. The final material choice was a high strength aluminium alloy with a T6 thermal treatment. The device was designed and calculated by use of CAD and FEM software respectively, aiming to reduce weight. After manufacturing the strength, usability and friction properties of the device have been successfully tested.
Agile Development of a Smartphone App for Perinatal Monitoring in a Resource-Constrained Setting
Martinez, Boris; Hall-Clifford, Rachel; Coyote, Enma; Stroux, Lisa; Valderrama, Camilo E.; Aaron, Christopher; Francis, Aaron; Hendren, Cate; Rohloff, Peter; Clifford, Gari D.
2017-01-01
Technology provides the potential to empower frontline healthcare workers with low levels of training and literacy, particularly in low- and middle-income countries. An obvious platform for achieving this aim is the smartphone, a low cost, almost ubiquitous device with good supply chain infrastructure and a general cultural acceptance for its use. In particular, the smartphone offers the opportunity to provide augmented or procedural information through active audiovisual aids to illiterate or untrained users, as described in this article. In this article, the process of refinement and iterative design of a smartphone application prototype to support perinatal surveillance in rural Guatemala for indigenous Maya lay midwives with low levels of literacy and technology exposure is described. Following on from a pilot to investigate the feasibility of this system, a two-year project to develop a robust in-field system was initiated, culminating in a randomized controlled trial of the system, which is ongoing. The development required an agile approach, with the development team working both remotely and in country to identify and solve key technical and cultural issues in close collaboration with the midwife end-users. This article describes this process and intermediate results. The application prototype was refined in two phases, with expanding numbers of end-users. Some of the key weaknesses identified in the system during the development cycles were user error when inserting and assembling cables and interacting with the 1-D ultrasound-recording interface, as well as unexpectedly poor bandwidth for data uploads in the central healthcare facility. Safety nets for these issues were developed and the resultant system was well accepted and highly utilized by the end-users. To evaluate the effectiveness of the system after full field deployment, data quality, and corruption over time, as well as general usage of the system and the volume of application support for end-users required by the in-country team was analyzed. Through iterative review of data quality and consistent use of user feedback, the volume and percentage of high quality recordings was increased monthly. Final analysis of the impact of the system on obstetrical referral volume and maternal and neonatal clinical outcomes is pending conclusion of the ongoing clinical trial. PMID:28936111
Agile Development of a Smartphone App for Perinatal Monitoring in a Resource-Constrained Setting.
Martinez, Boris; Hall-Clifford, Rachel; Coyote, Enma; Stroux, Lisa; Valderrama, Camilo E; Aaron, Christopher; Francis, Aaron; Hendren, Cate; Rohloff, Peter; Clifford, Gari D
2017-01-01
Technology provides the potential to empower frontline healthcare workers with low levels of training and literacy, particularly in low- and middle-income countries. An obvious platform for achieving this aim is the smartphone, a low cost, almost ubiquitous device with good supply chain infrastructure and a general cultural acceptance for its use. In particular, the smartphone offers the opportunity to provide augmented or procedural information through active audiovisual aids to illiterate or untrained users, as described in this article. In this article, the process of refinement and iterative design of a smartphone application prototype to support perinatal surveillance in rural Guatemala for indigenous Maya lay midwives with low levels of literacy and technology exposure is described. Following on from a pilot to investigate the feasibility of this system, a two-year project to develop a robust in-field system was initiated, culminating in a randomized controlled trial of the system, which is ongoing. The development required an agile approach, with the development team working both remotely and in country to identify and solve key technical and cultural issues in close collaboration with the midwife end-users. This article describes this process and intermediate results. The application prototype was refined in two phases, with expanding numbers of end-users. Some of the key weaknesses identified in the system during the development cycles were user error when inserting and assembling cables and interacting with the 1-D ultrasound-recording interface, as well as unexpectedly poor bandwidth for data uploads in the central healthcare facility. Safety nets for these issues were developed and the resultant system was well accepted and highly utilized by the end-users. To evaluate the effectiveness of the system after full field deployment, data quality, and corruption over time, as well as general usage of the system and the volume of application support for end-users required by the in-country team was analyzed. Through iterative review of data quality and consistent use of user feedback, the volume and percentage of high quality recordings was increased monthly. Final analysis of the impact of the system on obstetrical referral volume and maternal and neonatal clinical outcomes is pending conclusion of the ongoing clinical trial.
Development of a simulated smart pump interface.
Elias, Beth L; Moss, Jacqueline A; Shih, Alan; Dillavou, Marcus
2014-01-01
Medical device user interfaces are increasingly complex, resulting in a need for evaluation in clinicallyaccurate settings. Simulation of these interfaces can allow for evaluation, training, and use for research without the risk of harming patients and with a significant cost reduction over using the actual medical devices. This pilot project was phase 1 of a study to define and evaluate a methodology for development of simulated medical device interface technology to be used for education, device development, and research. Digital video and audio recordings of interface interactions were analyzed to develop a model of a smart intravenous medication infusion pump user interface. This model was used to program a high-fidelity simulated smart intravenous medication infusion pump user interface on an inexpensive netbook platform.
14 CFR 121.917 - Other requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... technical (piloting or other) skills in an actual or simulated operations scenario. For flight crewmembers this training and evaluation must be conducted in an approved flight training device, flight simulator... Dispatcher Resource Management (DRM) ground and if appropriate flight training applicable to each position...
14 CFR 121.917 - Other requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... technical (piloting or other) skills in an actual or simulated operations scenario. For flight crewmembers this training and evaluation must be conducted in an approved flight training device, flight simulator... Dispatcher Resource Management (DRM) ground and if appropriate flight training applicable to each position...
14 CFR 121.917 - Other requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... technical (piloting or other) skills in an actual or simulated operations scenario. For flight crewmembers this training and evaluation must be conducted in an approved flight training device, flight simulator... Dispatcher Resource Management (DRM) ground and if appropriate flight training applicable to each position...
14 CFR 121.917 - Other requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... technical (piloting or other) skills in an actual or simulated operations scenario. For flight crewmembers this training and evaluation must be conducted in an approved flight training device, flight simulator... Dispatcher Resource Management (DRM) ground and if appropriate flight training applicable to each position...
DOT National Transportation Integrated Search
1994-08-01
In his FY 92/93 Annual Program Guidance and Current Policy Statement, the Federal Air Surgeon requested continued investigation of new testing modalities, such as glare vision testing, as to their relevance to medical certification. Glare sensitivity...
DOT National Transportation Integrated Search
2009-04-27
Access to affordable and effective flight-simulation training devices (FSTDs) is critical to safely train airline crews in aviating, navigating, communicating, making decisions, and managing flight-deck and crew resources. This paper provides an over...
Xu, J C; Wang, L; Xu, G S; Luo, G N; Yao, D M; Li, Q; Cao, L; Chen, L; Zhang, W; Liu, S C; Wang, H Q; Jia, M N; Feng, W; Deng, G Z; Hu, L Q; Wan, B N; Li, J; Sun, Y W; Guo, H Y
2016-08-01
In order to withstand rapid increase in particle and power impact onto the divertor and demonstrate the feasibility of the ITER design under long pulse operation, the upper divertor of the EAST tokamak has been upgraded to actively water-cooled, ITER-like tungsten mono-block structure since the 2014 campaign, which is the first attempt for ITER on the tokamak devices. Therefore, a new divertor Langmuir probe diagnostic system (DivLP) was designed and successfully upgraded on the tungsten divertor to obtain the plasma parameters in the divertor region such as electron temperature, electron density, particle and heat fluxes. More specifically, two identical triple probe arrays have been installed at two ports of different toroidal positions (112.5-deg separated toroidally), which can provide fundamental data to study the toroidal asymmetry of divertor power deposition and related 3-dimension (3D) physics, as induced by resonant magnetic perturbations, lower hybrid wave, and so on. The shape of graphite tip and fixed structure of the probe are designed according to the structure of the upper tungsten divertor. The ceramic support, small graphite tip, and proper connector installed make it possible to be successfully installed in the very narrow interval between the cassette body and tungsten mono-block, i.e., 13.5 mm. It was demonstrated during the 2014 and 2015 commissioning campaigns that the newly upgraded divertor Langmuir probe diagnostic system is successful. Representative experimental data are given and discussed for the DivLP measurements, then proving its availability and reliability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loarte, A.; Polevoi, A. R.; Hosokawa, M.
2015-05-15
Experiments in Alcator C-Mod tokamak plasmas in the Enhanced D-alpha H-mode regime with ITER-like mid-radius plasma density peaking and Ion Cyclotron Resonant heating, in which tungsten is introduced by the laser blow-off technique, have demonstrated that accumulation of tungsten in the central region of the plasma does not take place in these conditions. The measurements obtained are consistent with anomalous transport dominating tungsten transport except in the central region of the plasma where tungsten transport is neoclassical, as previously observed in other devices with dominant neutral beam injection heating, such as JET and ASDEX Upgrade. In contrast to such results,more » however, the measured scale lengths for plasma temperature and density in the central region of these Alcator C-Mod plasmas, with density profiles relatively flat in the core region due to the lack of core fuelling, are favourable to prevent inter and intra sawtooth tungsten accumulation in this region under dominance of neoclassical transport. Simulations of ITER H-mode plasmas, including both anomalous (modelled by the Gyro-Landau-Fluid code GLF23) and neoclassical transport for main ions and tungsten and with density profiles of similar peaking to those obtained in Alcator C-Mod show that accumulation of tungsten in the central plasma region is also unlikely to occur in stationary ITER H-mode plasmas due to the low fuelling source by the neutral beam injection (injection energy ∼ 1 MeV), which is in good agreement with findings in the Alcator C-Mod experiments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, J. C.; Jia, M. N.; Feng, W.
2016-08-15
In order to withstand rapid increase in particle and power impact onto the divertor and demonstrate the feasibility of the ITER design under long pulse operation, the upper divertor of the EAST tokamak has been upgraded to actively water-cooled, ITER-like tungsten mono-block structure since the 2014 campaign, which is the first attempt for ITER on the tokamak devices. Therefore, a new divertor Langmuir probe diagnostic system (DivLP) was designed and successfully upgraded on the tungsten divertor to obtain the plasma parameters in the divertor region such as electron temperature, electron density, particle and heat fluxes. More specifically, two identical triplemore » probe arrays have been installed at two ports of different toroidal positions (112.5-deg separated toroidally), which can provide fundamental data to study the toroidal asymmetry of divertor power deposition and related 3-dimension (3D) physics, as induced by resonant magnetic perturbations, lower hybrid wave, and so on. The shape of graphite tip and fixed structure of the probe are designed according to the structure of the upper tungsten divertor. The ceramic support, small graphite tip, and proper connector installed make it possible to be successfully installed in the very narrow interval between the cassette body and tungsten mono-block, i.e., 13.5 mm. It was demonstrated during the 2014 and 2015 commissioning campaigns that the newly upgraded divertor Langmuir probe diagnostic system is successful. Representative experimental data are given and discussed for the DivLP measurements, then proving its availability and reliability.« less
Autocalibration method for non-stationary CT bias correction.
Vegas-Sánchez-Ferrero, Gonzalo; Ledesma-Carbayo, Maria J; Washko, George R; Estépar, Raúl San José
2018-02-01
Computed tomography (CT) is a widely used imaging modality for screening and diagnosis. However, the deleterious effects of radiation exposure inherent in CT imaging require the development of image reconstruction methods which can reduce exposure levels. The development of iterative reconstruction techniques is now enabling the acquisition of low-dose CT images whose quality is comparable to that of CT images acquired with much higher radiation dosages. However, the characterization and calibration of the CT signal due to changes in dosage and reconstruction approaches is crucial to provide clinically relevant data. Although CT scanners are calibrated as part of the imaging workflow, the calibration is limited to select global reference values and does not consider other inherent factors of the acquisition that depend on the subject scanned (e.g. photon starvation, partial volume effect, beam hardening) and result in a non-stationary noise response. In this work, we analyze the effect of reconstruction biases caused by non-stationary noise and propose an autocalibration methodology to compensate it. Our contributions are: 1) the derivation of a functional relationship between observed bias and non-stationary noise, 2) a robust and accurate method to estimate the local variance, 3) an autocalibration methodology that does not necessarily rely on a calibration phantom, attenuates the bias caused by noise and removes the systematic bias observed in devices from different vendors. The validation of the proposed methodology was performed with a physical phantom and clinical CT scans acquired with different configurations (kernels, doses, algorithms including iterative reconstruction). The results confirmed the suitability of the proposed methods for removing the intra-device and inter-device reconstruction biases. Copyright © 2017 Elsevier B.V. All rights reserved.
EBIT spectroscopy of highly charged heavy ions relevant to hot plasmas
NASA Astrophysics Data System (ADS)
Nakamura, Nobuyuki
2013-05-01
An electron beam ion trap (EBIT) is a versatile device for studying highly charged ions. We have been using two types of EBITs for the spectroscopic studies of highly charged ions. One is a high-energy device called the Tokyo-EBIT, and another is a compact low-energy device called CoBIT. Complementary use of them enables us to obtain spectroscopic data for ions over a wide charge-state range interacting with electrons over a wide energy range. In this talk, we present EBIT spectra of highly charged ions for tungsten, iron, bismuth, etc., which are relevant to hot plasmas. Tungsten is considered to be the main impurity in the ITER (the next generation nuclear fusion reactor) plasma, and thus its emission lines are important for diagnosing and controlling the ITER plasma. We have observed many previously unreported lines to supply the lack of spectroscopic data of tungsten ions. Iron is one of the main components of the solar corona, and its spectra are used to diagnose temperature, density, etc. The diagnostics is usually done by comparing observed spectra with model calculations. An EBIT can provide spectra under a well-defined condition; they are thus useful to test the model calculations. Laser-produced bismuth plasma is one of the candidates for a soft x-ray source in the water window region. An EBIT has a narrow charge state distribution; it is thus useful to disentangle the spectra of laser-produced plasma containing ions with a wide charge-state range. Performed with the support and under the auspices of the NIFS Collaboration Research program (NIFS09KOAJ003) and JSPS KAKENHI Number 23246165, and partly supported by the JSPS-NRF-NSFC A3 Foresight Program in the field of Plasma Physics.
Stopyra, Jason P; Winslow, James E; Fitzgerald, David M; Bozeman, William P
2017-11-01
Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead. Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed. A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices. In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette. Copyright © 2017. Published by Elsevier Ltd.
FPGA implementation of low complexity LDPC iterative decoder
NASA Astrophysics Data System (ADS)
Verma, Shivani; Sharma, Sanjay
2016-07-01
Low-density parity-check (LDPC) codes, proposed by Gallager, emerged as a class of codes which can yield very good performance on the additive white Gaussian noise channel as well as on the binary symmetric channel. LDPC codes have gained lots of importance due to their capacity achieving property and excellent performance in the noisy channel. Belief propagation (BP) algorithm and its approximations, most notably min-sum, are popular iterative decoding algorithms used for LDPC and turbo codes. The trade-off between the hardware complexity and the decoding throughput is a critical factor in the implementation of the practical decoder. This article presents introduction to LDPC codes and its various decoding algorithms followed by realisation of LDPC decoder by using simplified message passing algorithm and partially parallel decoder architecture. Simplified message passing algorithm has been proposed for trade-off between low decoding complexity and decoder performance. It greatly reduces the routing and check node complexity of the decoder. Partially parallel decoder architecture possesses high speed and reduced complexity. The improved design of the decoder possesses a maximum symbol throughput of 92.95 Mbps and a maximum of 18 decoding iterations. The article presents implementation of 9216 bits, rate-1/2, (3, 6) LDPC decoder on Xilinx XC3D3400A device from Spartan-3A DSP family.
NASA Astrophysics Data System (ADS)
Jin, Chengying; Li, Dahai; Kewei, E.; Li, Mengyang; Chen, Pengyu; Wang, Ruiyang; Xiong, Zhao
2018-06-01
In phase measuring deflectometry, two orthogonal sinusoidal fringe patterns are separately projected on the test surface and the distorted fringes reflected by the surface are recorded, each with a sequential phase shift. Then the two components of the local surface gradients are obtained by triangulation. It usually involves some complicated and time-consuming procedures (fringe projection in the orthogonal directions). In addition, the digital light devices (e.g. LCD screen and CCD camera) are not error free. There are quantization errors for each pixel of both LCD and CCD. Therefore, to avoid the complex process and improve the reliability of the phase distribution, a phase extraction algorithm with five-frame crossed fringes is presented in this paper. It is based on a least-squares iterative process. Using the proposed algorithm, phase distributions and phase shift amounts in two orthogonal directions can be simultaneously and successfully determined through an iterative procedure. Both a numerical simulation and a preliminary experiment are conducted to verify the validity and performance of this algorithm. Experimental results obtained by our method are shown, and comparisons between our experimental results and those obtained by the traditional 16-step phase-shifting algorithm and between our experimental results and those measured by the Fizeau interferometer are made.
Experimental Bayesian Quantum Phase Estimation on a Silicon Photonic Chip.
Paesani, S; Gentile, A A; Santagati, R; Wang, J; Wiebe, N; Tew, D P; O'Brien, J L; Thompson, M G
2017-03-10
Quantum phase estimation is a fundamental subroutine in many quantum algorithms, including Shor's factorization algorithm and quantum simulation. However, so far results have cast doubt on its practicability for near-term, nonfault tolerant, quantum devices. Here we report experimental results demonstrating that this intuition need not be true. We implement a recently proposed adaptive Bayesian approach to quantum phase estimation and use it to simulate molecular energies on a silicon quantum photonic device. The approach is verified to be well suited for prethreshold quantum processors by investigating its superior robustness to noise and decoherence compared to the iterative phase estimation algorithm. This shows a promising route to unlock the power of quantum phase estimation much sooner than previously believed.
Nonlinearity response correction in phase-shifting deflectometry
NASA Astrophysics Data System (ADS)
Nguyen, Manh The; Kang, Pilseong; Ghim, Young-Sik; Rhee, Hyug-Gyo
2018-04-01
Owing to the nonlinearity response of digital devices such as screens and cameras in phase-shifting deflectometry, non-sinusoidal phase-shifted fringe patterns are generated and additional measurement errors are introduced. In this paper, a new deflectometry technique is described for overcoming these problems using a pre-distorted pattern combined with an advanced iterative algorithm. The experiment results show that this method can reconstruct the 3D surface map of a sample without fringe print-through caused by the nonlinearity response of digital devices. The proposed technique is verified by measuring the surface height variations in a deformable mirror and comparing them with the measurement result obtained using a coordinate measuring machine. The difference between the two measurement results is estimated to be less than 13 µm.
Simulation of Aluminum Micro-mirrors for Space Applications at Cryogenic Temperatures
NASA Technical Reports Server (NTRS)
Kuhn, J. L.; Dutta, S. B.; Greenhouse, M. A.; Mott, D. B.
2000-01-01
Closed form and finite element models are developed to predict the device response of aluminum electrostatic torsion micro-mirrors fabricated on silicon substrate for space applications at operating temperatures of 30K. Initially, closed form expressions for electrostatic pressure arid mechanical restoring torque are used to predict the pull-in and release voltages at room temperature. Subsequently, a detailed mechanical finite element model is developed to predict stresses and vertical beam deflection induced by the electrostatic and thermal loads. An incremental and iterative solution method is used in conjunction with the nonlinear finite element model and closed form electrostatic equations to solve. the coupled electro-thermo-mechanical problem. The simulation results are compared with experimental measurements at room temperature of fabricated micro-mirror devices.
Enabling co-simulation of tokamak plant models and plasma control systems
Walker, M. L.
2017-12-22
A system for connecting the Plasma Control System and a model of the tokamak Plant in closed loop co-simulation for plasma control development has been in routine use at DIII-D for more than 20 years and at other fusion labs that use variants of the DIII-D PCS for approximately the last decade. Here, co-simulation refers to the simultaneous execution of two independent codes with the exchange of data - Plant actuator commands and tokamak diagnostic data - between them during execution. Interest in this type of PCS-Plant simulation technology has also been growing recently at other fusion facilities. In fact,more » use of such closed loop control simulations is assumed to play an even larger role in the development of both the ITER Plasma Control System (PCS) and the experimental operation of the ITER device, where they will be used to support verification/validation of the PCS and also for ITER pulse schedule development and validation. We describe the key use cases that motivate the co-simulation capability and the features that must be provided by the Plasma Control System to support it. These features could be provided by the PCS itself or by a model of the PCS. If the PCS itself is chosen to provide them, there are requirements imposed on its architecture. If a PCS model is chosen, there are requirements imposed on the initial implementation of this simulation as well as long-term consequences for its continued development and maintenance. We describe these issues for each use case and discuss the relative merits of the two choices. Several examples are given illustrating uses of the co-simulation method to address problems of plasma control during the operation of DIII-D and of other devices that use the DIII-D PCS.« less
Enabling co-simulation of tokamak plant models and plasma control systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, M. L.
A system for connecting the Plasma Control System and a model of the tokamak Plant in closed loop co-simulation for plasma control development has been in routine use at DIII-D for more than 20 years and at other fusion labs that use variants of the DIII-D PCS for approximately the last decade. Here, co-simulation refers to the simultaneous execution of two independent codes with the exchange of data - Plant actuator commands and tokamak diagnostic data - between them during execution. Interest in this type of PCS-Plant simulation technology has also been growing recently at other fusion facilities. In fact,more » use of such closed loop control simulations is assumed to play an even larger role in the development of both the ITER Plasma Control System (PCS) and the experimental operation of the ITER device, where they will be used to support verification/validation of the PCS and also for ITER pulse schedule development and validation. We describe the key use cases that motivate the co-simulation capability and the features that must be provided by the Plasma Control System to support it. These features could be provided by the PCS itself or by a model of the PCS. If the PCS itself is chosen to provide them, there are requirements imposed on its architecture. If a PCS model is chosen, there are requirements imposed on the initial implementation of this simulation as well as long-term consequences for its continued development and maintenance. We describe these issues for each use case and discuss the relative merits of the two choices. Several examples are given illustrating uses of the co-simulation method to address problems of plasma control during the operation of DIII-D and of other devices that use the DIII-D PCS.« less
Physics and engineering design of the accelerator and electron dump for SPIDER
NASA Astrophysics Data System (ADS)
Agostinetti, P.; Antoni, V.; Cavenago, M.; Chitarin, G.; Marconato, N.; Marcuzzi, D.; Pilan, N.; Serianni, G.; Sonato, P.; Veltri, P.; Zaccaria, P.
2011-06-01
The ITER Neutral Beam Test Facility (PRIMA) is planned to be built at Consorzio RFX (Padova, Italy). PRIMA includes two experimental devices: a full size ion source with low voltage extraction called SPIDER and a full size neutral beam injector at full beam power called MITICA. SPIDER is the first experimental device to be built and operated, aiming at testing the extraction of a negative ion beam (made of H- and in a later stage D- ions) from an ITER size ion source. The main requirements of this experiment are a H-/D- extracted current density larger than 355/285 A m-2, an energy of 100 keV and a pulse duration of up to 3600 s. Several analytical and numerical codes have been used for the design optimization process, some of which are commercial codes, while some others were developed ad hoc. The codes are used to simulate the electrical fields (SLACCAD, BYPO, OPERA), the magnetic fields (OPERA, ANSYS, COMSOL, PERMAG), the beam aiming (OPERA, IRES), the pressure inside the accelerator (CONDUCT, STRIP), the stripping reactions and transmitted/dumped power (EAMCC), the operating temperature, stress and deformations (ALIGN, ANSYS) and the heat loads on the electron dump (ED) (EDAC, BACKSCAT). An integrated approach, taking into consideration at the same time physics and engineering aspects, has been adopted all along the design process. Particular care has been taken in investigating the many interactions between physics and engineering aspects of the experiment. According to the 'robust design' philosophy, a comprehensive set of sensitivity analyses was performed, in order to investigate the influence of the design choices on the most relevant operating parameters. The design of the SPIDER accelerator, here described, has been developed in order to satisfy with reasonable margin all the requirements given by ITER, from the physics and engineering points of view. In particular, a new approach to the compensation of unwanted beam deflections inside the accelerator and a new concept for the ED have been introduced.
Thermonuclear Power Engineering: 60 Years of Research. What Comes Next?
NASA Astrophysics Data System (ADS)
Strelkov, V. S.
2017-12-01
This paper summarizes results of more than half a century of research of high-temperature plasmas heated to a temperature of more than 100 million degrees (104 eV) and magnetically insulated from the walls. The energy of light-element fusion can be used for electric power generation or as a source of fissionable fuel production (development of a fusion neutron source—FNS). The main results of studies of tokamak plasmas which were obtained in the Soviet Union with the greatest degree of thermal plasma isolation among all other types of devices are presented. As a result, research programs of other countries were redirected to tokamaks. Later, on the basis of the analysis of numerous experiments, the international fusion community gradually came to an opinion that it is possible to build a tokamak (ITER) with Q > 1 (where Q is the ratio of the fusion power to the external power injected into the plasma). The ITER program objective is to achieve Q = 1-10 for a discharge time of up to 1000 s. The implementation of this goal does not solve the problem of a steadystate operation. The solution to this problem is a reliable first wall and current generation. This is a task of the next fusion power plant construction stage, called DEMO. Comparison of DEMO and FNS parameters shows that, at this development stage, the operating parameters and conditions of these devices are identical.
Nestlerode, J.A.; Engle, V.D.; Bourgeois, P.; Heitmuller, P.T.; Macauley, J.M.; Allen, Y.C.
2009-01-01
The Environmental Protection Agency (EPA) and U.S. Geological Survey (USGS) initiated a two-year regional pilot survey in 2007 to develop, test, and validate tools and approaches to assess the condition of northern Gulf of Mexico (GOM) coastal wetlands. Sampling sites were selected from estuarine and palustrine wetland areas with herbaceous, forested, and shrub/scrub habitats delineated by the US Fish and Wildlife Service National Wetlands Inventory Status and Trends (NWI S&T) program and contained within northern GOM coastal watersheds. A multi-level, stepwise, iterative survey approach is being applied to multiple wetland classes at 100 probabilistically-selected coastal wetlands sites. Tier 1 provides information at the landscape scale about habitat inventory, land use, and environmental stressors associated with the watershed in which each wetland site is located. Tier 2, a rapid assessment conducted through a combination of office and field work, is based on best professional judgment and on-site evidence. Tier 3, an intensive site assessment, involves on-site collection of vegetation, water, and sediment samples to establish an integrated understanding of current wetland condition and validate methods and findings from Tiers 1 and 2. The results from this survey, along with other similar regional pilots from the Mid-Atlantic, West Coast, and Great Lakes Regions will contribute to a design and implementation approach for the National Wetlands Condition Assessment to be conducted by EPA's Office of Water in 2011. ?? Springer Science+Business Media B.V. 2008.
The Child Abuse Potential Inventory: Development of an Arabic version.
Al Abduwani, Jumana; Sidebotham, Peter; Al Saadoon, Muna; Al Lawati, Mohammed; Barlow, Jane
2017-10-01
The Child Abuse Potential Inventory (CAPI) is a well-validated screening tool for assessing potential for child physical abuse, and has been translated into many different languages. To date the CAPI has not been translated into Arabic or used in any studies in Arabic-speaking populations. This study reports on the process of adapting the CAPI into Arabic Language which was undertaken following the International Society of Pharma-economics and Outcomes Research (ISPOR) guidelines. The translation/adaptation process was multi-stage, and involved the use of a Delphi process, cognitive debriefing, back translation, and a pilot testing of the Arabic CAPI at two primary health care centers with a population of pregnant women (n=60). Following "literal translation" 73 out of the 160 items needed re-phrasing to adapt the items to the Oman context. No differences were found when comparing results of the translated or back-translated versions to source; however, eight items needed further amendment following translated to back-translated comparison and feedback from the pilot. Iterations were resolved following in-depth interviews. Discrepancies were due to differences in culture, parenting practices, and religion. Piloting of the tool indicated mean score value of 155.8 (SD=59.4) and eleven women (18%) scored above the cut off value of 215. This Arabic translation of the CAPI was undertaken using rigorous methodology and sets the scene for further research on the Arabic CAPI within Arabic-speaking populations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Asian Women's Action for Resilience and Empowerment Intervention: Stage I Pilot Study.
Hahm, Hyeouk Chris; Chang, Stephanie Tzu-Han; Lee, Gloria Yoonseung; Tagerman, Michelle D; Lee, Christina S; Trentadue, Mia Pamela; Hien, Denise A
2017-01-01
This study describes the development and pilot test of Asian Women's Action for Resilience and Empowerment (AWARE), a culturally informed group psychotherapy intervention designed to reduce depressive symptoms, suicidality, substance use, and HIV and sexual risk behaviors among 1.5 and second generation Asian American (AA) women. To participate, AA women had to meet the criteria for posttraumatic stress disorder (PTSD) or have a history of exposure to interpersonal violence (IPV) as determined using the Clinician-Administered PTSD Scale (CAPS) and Traumatic Life Events Questionnaire (TLEQ). This article also presents the preliminary feasibility and acceptability of AWARE from its Stage I pilot study of nine Chinese, Korean, and Vietnamese American women. To foster holistic treatment, AWARE was developed based on original research findings from Stage 0 and integrated theoretical models including fractured identity theory, empowerment theory, cognitive behavioral therapy (CBT), mindfulness-based techniques, and the AIDS Risk Reduction Model (ARRM). The development of AWARE was an iterative process informed by participant feedback, which led to frequent intervention modifications for a future randomized controlled trial (RCT) in Stage II. A qualitative analysis of participant feedback informed the following modifications: further exploration of feelings, improvements in technology delivery, learning and practicing coping skills, more specific cultural tailoring related to sexual health, decreased number of sessions and increased time per session. Findings provide support for the acceptability and feasibility of AWARE as "culturally informed" for AA young women with IPV histories, high-risk behaviors, and mental health issues.
NASA Astrophysics Data System (ADS)
Freer, J. E.; Bloomfield, J. P.; Johnes, P. J.; MacLeod, C.; Reaney, S.
2010-12-01
There are many challenges in developing effective and integrated catchment management solutions for hydrology and water quality issues. Such solutions should ideally build on current scientific evidence to inform policy makers and regulators and additionally allow stakeholders to take ownership of local and/or national issues, in effect bringing together ‘communities of practice’. A strategy being piloted in the UK as the Pilot Virtual Observatory (pVO), funded by NERC, is to demonstrate the use of cyber-infrastructure and cloud computing resources to investigate better methods of linking data and models and to demonstrate scenario analysis for research, policy and operational needs. The research will provide new ways the scientific and stakeholder communities come together to exploit current environmental information, knowledge and experience in an open framework. This poster presents the project scope and methodologies for the pVO work dealing with national modelling of hydrology and macro-nutrient biogeochemistry. We evaluate the strategies needed to robustly benchmark our current predictive capability of these resources through ensemble modelling. We explore the use of catchment similarity concepts to understand if national monitoring programs can inform us about the behaviour of catchments. We discuss the challenges to applying these strategies in an open access and integrated framework and finally we consider the future for such virtual observatory platforms for improving the way we iteratively improve our understanding of catchment science.
Weiner, Saul J; Schwartz, Alan; Yudkowsky, Rachel; Schiff, Gordon D; Weaver, Frances M; Goldberg, Julie; Weiss, Kevin B
2007-01-01
Clinical decision making requires 2 distinct cognitive skills: the ability to classify patients' conditions into diagnostic and management categories that permit the application of research evidence and the ability to individualize or-more specifically-to contextualize care for patients whose circumstances and needs require variation from the standard approach to care. The purpose of this study was to develop and test a methodology for measuring physicians' performance at contextualizing care and compare it to their performance at planning biomedically appropriate care. First, the authors drafted 3 cases, each with 4 variations, 3 of which are embedded with biomedical and/or contextual information that is essential to planning care. Once the cases were validated as instruments for assessing physician performance, 54 internal medicine residents were then presented with opportunities to make these preidentified biomedical or contextual errors, and data were collected on information elicitation and error making. The case validation process was successful in that, in the final iteration, the physicians who received the contextual variant of cases proposed an alternate plan of care to those who received the baseline variant 100% of the time. The subsequent piloting of these validated cases unmasked previously unmeasured differences in physician performance at contextualizing care. The findings, which reflect the performance characteristics of the study population, are presented. This pilot study demonstrates a methodology for measuring physician performance at contextualizing care and illustrates the contribution of such information to an overall assessment of physician practice.
Rotary acceleration of a subject inhibits choice reaction time to motion in peripheral vision
NASA Technical Reports Server (NTRS)
Borkenhagen, J. M.
1974-01-01
Twelve pilots were tested in a rotation device with visual simulation, alone and in combination with rotary stimulation, in experiments with variable levels of acceleration and variable viewing angles, in a study of the effect of S's rotary acceleration on the choice reaction time for an accelerating target in peripheral vision. The pilots responded to the direction of the visual motion by moving a hand controller to the right or left. Visual-plus-rotary stimulation required a longer choice reaction time, which was inversely related to the level of acceleration and directly proportional to the viewing angle.
NASA Technical Reports Server (NTRS)
Chamberlain, Jim; Latorella, Kara
2003-01-01
This viewgraph presentation provides information on an airborne experiment designed to test the decision making of pilots receiving different sources of meteorological data. The presentation covers the equipment used in the COnvective Weather Sources (CoWS) Experiment), including the information system and display devices available to some of the subjects. It also describes the experiment, which featured teams of general aviation pilots, who were onboard but did not actually fly the aircraft used in the experiment. The presentation includes the results of a survey of the subjects' confidence.
Evaluation of control and display configurations for helicopter shipboard operations
NASA Technical Reports Server (NTRS)
Paulk, C. H., Jr.; Donley, S. T.; Hollis, M. K.
1983-01-01
A simulation evaluation of several approach and landing flight-control configurations and of two out-of-the-cockpit display devices (a head-up display and a helmet-mounted display) was performed for the task of landing a helicopter on a destroyer in adverse weather. The results indicated that the ship airwake turbulence was the most significant environmental variable affecting hover performance. In addition, to achieve adequate landing performance, attitude-command control compensation was required for the pilot regardless of the display used. For improved performance with reduced pilot effort, a velocity-command, position-hold control system was desired.
Hamilton, Caroline; D'Arcy, Shona; Pearlmutter, Barak A; Crispino, Gloria; Lalor, Edmund C; Conlon, Brendan J
2016-12-01
Tinnitus is the perception of sound in the absence of an external auditory stimulus. It is widely believed that tinnitus, in patients with associated hearing loss, is a neurological phenomenon primarily affecting the central auditory structures. However, there is growing evidence for the involvement of the somatosensory system in this form of tinnitus. For this reason it has been suggested that the condition may be amenable to bi-modal stimulation of the auditory and somatosensory systems. We conducted a pilot study to investigate the feasibility and safety of a device that delivers simultaneous auditory and somatosensory stimulation to treat the symptoms of chronic tinnitus. A cohort of 54 patients used the stimulation device for 10 weeks. Auditory stimulation was delivered via headphones and somatosensory stimulation was delivered via electrical stimulation of the tongue. Patient usage, logged by the device, was used to classify patients as compliant or noncompliant. Safety was assessed by reported adverse events and changes in tinnitus outcome measures. Response to treatment was assessed using tinnitus outcome measures: Minimum Masking Level (MML), Tinnitus Loudness Matching (TLM), and Tinnitus Handicap Inventory (THI). The device was well tolerated by patients and no adverse events or serious difficulties using the device were reported. Overall, 68% of patients met the defined compliance threshold. Compliant patients (N = 30) demonstrated statistically significant improvements in mean outcome measures after 10 weeks of treatment: THI (-11.7 pts, p < 0.001), TLM (-7.5dB, p < 0.001), and MML (-9.7dB, p < 0.001). The noncompliant group (N = 14) demonstrated no statistical improvements. This study demonstrates the feasibility and safety of a new bi-modal stimulation device and supports the potential efficacy of this new treatment for tinnitus. © 2016 Neuromod Devices Ltd. Neuromodulation: Technology at the Neural Interface published by Wiley Periodicals, Inc. on behalf of International Neuromodulation Society.
14 CFR 23.395 - Control system loads.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Control system loads. 23.395 Section 23.395 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... and automatic devices operating the controls. However, autopilot forces need not be added to pilot...
14 CFR 23.395 - Control system loads.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Control system loads. 23.395 Section 23.395 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... and automatic devices operating the controls. However, autopilot forces need not be added to pilot...
14 CFR 23.395 - Control system loads.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Control system loads. 23.395 Section 23.395 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS... and automatic devices operating the controls. However, autopilot forces need not be added to pilot...
DOT National Transportation Integrated Search
2013-01-01
The simulator was once a very expensive, large-scale mechanical device for training military pilots or astronauts. Modern computers, linking sophisticated software and large-screen displays, have yielded simulators for the desktop or configured as sm...
47 CFR 90.429 - Control point and dispatch point requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 90.429 Section 90.429 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND...-operated device which will provide continuous visual indication when the transmitter is radiating, or, a pilot lamp or meter which will provide continuous visual indication when the transmitter circuits have...
Trial of a slant visual range measuring device
NASA Technical Reports Server (NTRS)
Streicher, J.; Muenkel, C.; Borchardt, H.
1992-01-01
Each year, fog at airports renders some landing operations either difficult or impossible. The visibility that a pilot of a landing aircraft can expect is in that case the most important information. It could happen that the visibility versus the altitude is constantly decreasing or increasing. However, it is not possible to distinguish this with the existing sensors at an airport. If the visibility is decreasing with the altitude, one has the worst case - ground fog. The standard visibility sensor, the transmissometer, determines only the horizontal visual range, which will be underestimated in comparison with the real visibility a pilot has on his landing approach. Described here is a new technique to measure the slant visual range, making use of a slant scanning device - an eye-safe laser radar. A comparison with commercial visibility sensors shows that it is possible to measure visibilities with the slant looking laser radar in the range from 50 meters up to 2000 meters and even distinguish inhomogenities like ground fog.
A pilot study of magnetic therapy for hot flashes after breast cancer.
Carpenter, Janet S; Wells, Nancy; Lambert, Beth; Watson, Peggy; Slayton, Tami; Chak, Bapsi; Hepworth, Joseph T; Worthington, W Bradley
2002-04-01
The purpose of this randomized placebo-controlled crossover pilot study was to evaluate the effectiveness and acceptability of magnetic therapy for hot flashes among breast cancer survivors. Participants completed a 24-hour baseline hot-flash monitoring session, wore the magnetic devices or placebo for 3 days, completed an after-treatment hot-flash monitoring session, experienced a 10-day washout period, and then crossed over to the opposite study arm. Magnetic devices and placebos were placed on 6 acupressure sites corresponding to hot-flash relief. Complete data were available from 11 survivors of breast cancer. Results indicated magnetic therapy was no more effective than placebo in decreasing hot-flash severity, and contrary to expectations, placebo was significantly more effective than magnets in decreasing hot-flash frequency, bother, interference with daily activities, and overall quality of life. Implications for clinical practice and future research include the need to explore alternative interventions aimed at alleviating hot flashes in this population.
Chu, Joyce P.; Huynh, Loanie; Areán, Patricia
2011-01-01
Objectives Main objectives were to familiarize the reader with a theoretical framework for modifying evidence-based interventions for cultural groups, and to provide an example of one method, Formative Method for Adapting Psychotherapies (FMAP), in the adaptation of an evidence-based intervention for a cultural group notorious for refusing mental health treatment. Methods Provider and client stakeholder input combined with an iterative testing process within the FMAP framework was utilized to create the Problem Solving Therapy—Chinese Older Adult (PST-COA) manual for depression. Data from pilot-testing the intervention with a clinically depressed Chinese elderly woman are reported. Results PST-COA is categorized as a ‘culturally-adapted’ treatment, where core mediating mechanisms of PST were preserved, but cultural themes of measurement methodology, stigma, hierarchical provider-client relationship expectations, and acculturation enhanced core components to make PST more understandable and relevant for Chinese elderly. Modifications also encompassed therapeutic framework and peripheral elements affecting engagement and retention. PST-COA applied with a depressed Chinese older adult indicated remission of clinical depression and improvement in mood. Fidelity with and acceptability of the treatment was sufficient as the client completed and reported high satisfaction with PST-COA. Conclusions PST, as a non-emotion-focused, evidence-based intervention, is a good fit for depressed Chinese elderly. Through an iterative stakeholder process of cultural adaptation, several culturally-specific modifications were applied to PST to create the PST-COA manual. PST-COA preserves core therapeutic PST elements but includes cultural adaptations in therapeutic framework and key administration and content areas that ensure greater applicability and effectiveness for the Chinese elderly community. PMID:21500283
The use of a tactile interface to convey position and motion perceptions
NASA Technical Reports Server (NTRS)
Rupert, A. H.; Guedry, F. E.; Reschke, M. F.
1994-01-01
Under normal terrestrial conditions, perception of position and motion is determined by central nervous system integration of concordant and redundant information from multiple sensory channels (somatosensory, vestibular, visual), which collectively yield vertical perceptions. In the acceleration environment experienced by the pilots, the somatosensory and vestibular sensors frequently present false information concerning the direction of gravity. When presented with conflicting sensory information, it is normal for pilots to experience episodes of disorientation. We have developed a tactile interface that obtains vertical roll and pitch information from a gyro-stabilized attitude indicator and maps this information in a one-to-one correspondence onto the torso of the body using a matrix of vibrotactors. This enables the pilot to continuously maintain an awareness of aircraft attitude without reference to visual cues, utilizing a sensory channel that normally operates at the subconscious level. Although initially developed to improve pilot spatial awareness, this device has obvious applications to 1) simulation and training, 2) nonvisual tracking of targets, which can reduce the need for pilots to make head movements in the high-G environment of aerial combat, and 3) orientation in environments with minimal somatosensory cues (e.g., underwater) or gravitational cues (e.g., space).