Comparison of adverse events of laser and light-assisted hair removal systems in skin types IV-VI.
Breadon, Jonith Y; Barnes, Chad A
2007-01-01
Photoepilation, utilizing lasers and noncoherent light sources, is designed to irradiate as much of the follicular unit as possible, with melanin as the target chromophore. Wavelength absorption should generate energy sufficient to heat and destroy the hair follicle, while preserving the surrounding tissue. When performing photoepilation on African-American skin (Fitzpatrick skin types IV-VI) a greater risk of potential epidermal adverse events, such as dyspigmentation, blistering, crusting, edema, and subsequent scarring, is possible. To reduce epidermal melanin absorption of energy longer wavelengths are considered safer for use on Fitzpatrick skin types IV to VI. This article reviews and compares the reported incidences of adverse events in African-American skin, utilizing lasers and noncoherent light sources for assisted hair removal.
Gulubova, M V
1996-07-01
Extrahepatic cholestasis causes excessive extracellular matrix formation perisinusoidally. Ito cells, transitional and endothelial cells are considered to be a source of extracellular matrix proteins in experimental cholestasis. The localization of collagens type III and type IV in human liver in extrahepatic cholestasis was investigated immunohistochemically in the present study. Immersion fixation was used after modification to be applied to surgical biopsies with commercially available kits. Sinusoidal changes were observed that indicated excessive collagen and matrix formation. Light microscopically, increased immunostaining with the two collagen antibodies was found perisinusoidally and portally. Ultrastructurally, collagen type III positive fibres were found beneath basement membranes of vessels, in collagen bundles and as a fibrillar network in the space of Disse. Collagen type IV immunostaining was located in portal tracts and near hepatocyte microvilli. Intracellular staining with collagen type IV was detected in the rough endoplasmic reticulum of some transitional cells. Immunostaining was located around transitional cells, Ito cells or endothelial cells mainly. Our study indicates that Ito cells, transitional and endothelial cells are the main source of collagens type III and IV in the space of Disse in extrahepatic cholestasis in humans.
Introduction to basic solar cell measurements
NASA Technical Reports Server (NTRS)
Brandhorst, H. W., Jr.
1976-01-01
The basic approaches to solar cell performance and diagnostic measurements are described. The light sources, equipment for I-V curve measurement, and the test conditions and procedures for performance measurement are detailed. Solar cell diagnostic tools discussed include analysis of I-V curves, series resistance and reverse saturation current determination, spectral response/quantum yield measurement, and diffusion length/lifetime determination.
Brown, Alia S; Hussain, Mussarat; Goldberg, David J
2011-12-01
Melasma is a common condition affecting over six million American women. Treatment of dermal or combined melasma is difficult and does not respond well to conventional topical therapies. Various light sources have been used recently in the treatment of melasma including fractionated ablative and non-ablative lasers as well as intense pulse light. We report the use of low fluence, large spot size Q-switched, Nd:Yag laser for the treatment of melasma in skin types II-IV.
Towards a 4{sup th} generation storage ring at the Canadian Light Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dallin, Les; Wurtz, Ward
2016-07-27
Demands from beamline scientists for more brilliant sources of synchrotron radiation have resulted in the emergence of 4{sup th} generation (diffraction-limited) storage rings. The practical development of the multi-bend achromat (MBA) concept by MAX IV lab has spurred many synchrotron light sources around the world to develop similar machines. For existing facilities two options are available: upgrading existing machines or building a new structure. The Canadian Light Source (CLS) has explored both options. For a new low emittance source in the existing CLS tunnel a decrease in electron energy would be required. A machine similar to the ALS upgrade couldmore » be contemplated. To achieve low emittance at our present energy of 2.9 GeV a new storage ring is desirable. Several options have been investigated. These designs use extremely strong focusing magnets to achieve extremely low emittances in compact lattice achromats.« less
Fayne, Rachel A; Perper, Marina; Eber, Ariel E; Aldahan, Adam S; Nouri, Keyvan
2018-04-01
Unwanted facial and body hair presents as a common finding in many patients, such as females with hirsutism. With advances in laser and light technology, a clinically significant reduction in hair can be achieved in patients with light skin. However, in patients with darker skin, Fitzpatrick skin types (FST) IV-VI, the higher melanin content of the skin interferes with the proposed mechanism of laser-induced selective photothermolysis, which is to target the melanin in the hair follicle to cause permanent destruction of hair bulge stem cells. Many prospective and retrospective studies have been conducted with laser and light hair-removal devices, but most exclude patients with darkly pigmented skin, considering them a high-risk group for unwanted side effects, including pigmentation changes, blisters, and crust formation. We reviewed the published literature to obtain studies that focused on hair reduction for darker skin types. The existing literature for this patient population identifies longer wavelengths as a key element of the treatment protocol and indicates neodymium-doped yttrium aluminum garnet (Nd:YAG), diode, alexandrite, and ruby lasers as well as certain intense pulsed light sources for safe hair reduction with minimal side effects in patients with FST IV-VI, so long as energy settings and wavelengths are appropriate. Based on the findings in this review, safe and effective hair reduction for patients with FST IV-VI is achievable under proper treatment protocols and energy settings.
Perry, Andrew M; Caviness, Alison Chantal; Hsu, Deborah C
2011-01-01
To determine whether the use of a near-infrared light venipuncture aid (VeinViewer; Luminetx Corporation, Memphis, Tenn) would improve the rate of successful first-attempt placement of intravenous (IV) catheters in a high-volume pediatric emergency department (ED). Patients younger than 20 years with standard clinical indications for IV access were randomized to have IV placement by ED nurses (in 3 groups stratified by 5-year blocks of nursing experience) using traditional methods (standard group) or with the aid of the near-infrared light source (device group). If a vein could not be cannulated after 3 attempts, patients crossed over from one study arm to the other, and study nurses attempted placement with the alternative technique. The primary end point was first-attempt success rate for IV catheter placement. After completion of patient enrollment, a questionnaire was completed by study nurses as a qualitative assessment of the device. A total of 123 patients (median age, 3 years) were included in the study: 62 in the standard group and 61 in the device group. There was no significant difference in first-attempt success rate between the standard (79.0%, 95% confidence interval [CI], 66.8%-88.3%) and device (72.1%, 95% CI, 59.2%-82.9%) groups. Of the 19 study nurses, 14 completed the questionnaire of whom 70% expressed neutral or unfavorable assessments of the device in nondehydrated patients without chronic underlying medical conditions and 90% found the device a helpful tool for patients in whom IV access was difficult. First-attempt success rate for IV placement was nonsignificantly higher without than with the assistance of a near-infrared light device in a high-volume pediatric ED. Nurses placing IVs did report several benefits to use of the device with specific patient groups, and future research should be conducted to demonstrate the role of the device in these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borland, M.; Hettel, R.; Leemann, S. C.
With the recent success in commissioning of MAX IV, the multi-bend achromat (MBA) lattice has begun to deliver on its promise to usher in a new generation of higher-brightness synchrotron light sources. In this paper, we begin by reviewing the challenges, recent success, and lessons learned of the MAX-IV project. Drawing on these lessons, we then describe the physics challenges in even more ambitious rings and how these can be met. In addition, we touch on engineering issues and choices that are tightly linked with the physics design.
NASA Astrophysics Data System (ADS)
Mintairov, M. A.; Evstropov, V. V.; Mintairov, S. A.; Shvarts, M. Z.; Kozhukhovskaia, S. A.; Kalyuzhnyy, N. A.
2017-11-01
The existence within monolithic double- and triple-junction solar cells of a photoelectric source, which counteracts the basic photovoltaic p-n junctions, is proved. The paper presents a detailed analysis of the shape of the light IV-characteristics, as well as the dependence Voc-Jsc (open circuit voltage - short-circuit current). It is established that the counteracting source is tunnel p+-n+ junction. The photoelectric characteristics of samples with different tunnel diode peak current values were investigated, including the case of a zero value. When the tunnel p+-n+ junction is photoactive, the Voc-Jsc dependence has a dropping part, including a sharp jump. This undesirable effect decreases with increasing peak current.
Impact of long-wavelength UVA and visible light on melanocompetent skin.
Mahmoud, Bassel H; Ruvolo, Eduardo; Hexsel, Camile L; Liu, Yang; Owen, Michael R; Kollias, Nikiforos; Lim, Henry W; Hamzavi, Iltefat H
2010-08-01
The purpose of this study was to determine the effect of visible light on the immediate pigmentation and delayed tanning of melanocompetent skin; the results were compared with those induced by long-wavelength UVA (UVA1). Two electromagnetic radiation sources were used to irradiate the lower back of 20 volunteers with skin types IV-VI: UVA1 (340-400 nm) and visible light (400-700 nm). Pigmentation was assessed by visual examination, digital photography with a cross-polarized filter, and diffused reflectance spectroscopy at 7 time points over a 2-week period. Confocal microscopy and skin biopsies for histopathological examination using different stains were carried out. Irradiation was also carried out on skin type II. Results showed that although both UVA1 and visible light can induce pigmentation in skin types IV-VI, pigmentation induced by visible light was darker and more sustained. No pigmentation was observed in skin type II. The quality and quantity of pigment induced by visible light and UVA1 were different. These findings have potential implications on the management of photoaggravated pigmentary disorders, the proper use of sunscreens, and the treatment of depigmented lesions.
Yeung, Edward S.; Gong, Xiaoyi
2004-09-07
The present invention provides a method of analyzing multiple samples simultaneously by absorption detection. The method comprises: (i) providing a planar array of multiple containers, each of which contains a sample comprising at least one absorbing species, (ii) irradiating the planar array of multiple containers with a light source and (iii) detecting absorption of light with a detetion means that is in line with the light source at a distance of at leaat about 10 times a cross-sectional distance of a container in the planar array of multiple containers. The absorption of light by a sample indicates the presence of an absorbing species in it. The method can further comprise: (iv) measuring the amount of absorption of light detected in (iii) indicating the amount of the absorbing species in the sample. Also provided by the present invention is a system for use in the abov metho.The system comprises; (i) a light source comrnpising or consisting essentially of at leaat one wavelength of light, the absorption of which is to be detected, (ii) a planar array of multiple containers, and (iii) a detection means that is in line with the light source and is positioned in line with and parallel to the planar array of multiple contiainers at a distance of at least about 10 times a cross-sectional distance of a container.
Zhou, Xu; Li, Fei; Li, Xiaona; Li, Hua; Wang, Yong; Sun, Licheng
2015-01-14
Photocatalytic oxidation of organic compounds proceeded efficiently in a hybrid system with ruthenium aqua complexes as catalysts, BiVO4 as a light absorber, [Co(NH3)5Cl](2+) as a sacrificial electron acceptor and water as an oxygen source. The photogenerated holes in the semiconductor are used to oxidize molecular catalysts into the high-valent Ru(IV)=O intermediates for 2e(-) oxidation.
Overview of Lattice Design and Evaluation for the APS Upgrade
Borland, M.; Emery, L.; Lindberg, R.; ...
2017-08-01
The Advanced Photon Source (APS) is a 7-GeV synchrotron light source that has been in operation since 1996. Since that time, the effective emittance has been decreased from 8 nm to 3.1 nm, which is very competitive for a 3rd-generation light source. However, newer facilities such as PETRA-III, NSLS-II, and MAX-IV are pushing the emittance to significantly smaller values. MAX-IV in particular has set the current benchmark with an emittance of about 300 pm at 3 GeV. This was accomplished by use of a multi-bend achromat lattice, which takes advantage of the 1/M3 scaling of the emittance with respect tomore » the number of dipoles M. In order to ensure that our facility remains competitive, APS is pursuing a major upgrade, which involves replacement of the existing double-bend lattice with a seven-bend achromat lattice, promising a 40-fold reduction in emittance. This paper describes the process of developing and evaluating candidate lattice designs. Two candidate 6-GeV lattices are described: one providing a natural emittance of 67 pm and the other providing 41 pm. Our analysis includes single-particle dynamics as well as single- and multi-bunch collective effects.« less
Application of Geodetic VLBI Data to Obtaining Long-Term Light Curves for Astrophysics
NASA Technical Reports Server (NTRS)
Kijima, Masachika
2010-01-01
The long-term light curve is important to research on binary black holes and disk instability in AGNs. The light curves have been drawn mainly using single dish data provided by the University of Michigan Radio Observatory and the Metsahovi Radio Observatory. Hence, thus far, we have to research on limited sources. I attempt to draw light curves using VLBI data for those sources that have not been monitored by any observatories with single dish. I developed software, analyzed all geodetic VLBI data available at the IVS Data Centers, and drew the light curves at 8 GHz. In this report, I show the tentative results for two AGNs. I compared two light curves of 4C39.25, which were drawn based on single dish data and on VLBI data. I confirmed that the two light curves were consistent. Furthermore, I succeeded in drawing the light curve of 0454-234 with VLBI data, which has not been monitored by any observatory with single dish. In this report, I suggest that the geodetic VLBI archive data is useful to obtain the long-term light curves at radio bands for astrophysics.
Beam dynamics and expected performance of Sweden's new storage-ring light source: MAX IV
NASA Astrophysics Data System (ADS)
Leemann, S. C.; Andersson, Å.; Eriksson, M.; Lindgren, L.-J.; Wallén, E.; Bengtsson, J.; Streun, A.
2009-12-01
MAX IV will be Sweden’s next-generation high-performance synchrotron radiation source. The project has recently been granted funding and construction is scheduled to begin in 2010. User operation for a broad and international user community should commence in 2015. The facility is comprised of two storage rings optimized for different wavelength ranges, a linac-based short-pulse facility and a free-electron laser for the production of coherent radiation. The main radiation source of MAX IV will be a 528 m ultralow emittance storage ring operated at 3 GeV for the generation of high-brightness hard x rays. This storage ring was designed to meet the requirements of state-of-the-art insertion devices which will be installed in nineteen 5 m long dispersion-free straight sections. The storage ring is based on a novel multibend achromat design delivering an unprecedented horizontal bare lattice emittance of 0.33 nm rad and a vertical emittance below the 8 pm rad diffraction limit for 1 Å radiation. In this paper we present the beam dynamics considerations behind this storage-ring design and detail its expected unique performance.
High School English IV: Social Consciousness in the American Novel, 1900-1950.
ERIC Educational Resources Information Center
Phillips, James A.
This university independent course of study on the contemporary American novel is presented to bring to light a source of social significance in America. Four novels are studied: Upton Sinclair's "The Jungle," John Steinbeck's "The Grapes of Wrath" and "Of Mice and Men," and Harper Lee's "To Kill a Mockingbird." Nine assignments are included. (CK)
Asymmetric distribution of type IV pili triggered by directional light in unicellular cyanobacteria
Nishizaka, Takayuki
2017-01-01
The type IV pili (T4P) system is a supermolecular machine observed in prokaryotes. Cells repeat the cycle of T4P extension, surface attachment, and retraction to drive twitching motility. Although the properties of T4P as a motor have been scrutinized with biophysics techniques, the mechanism of regulation remains unclear. Here we provided the framework of the T4P dynamics at the single-cell level in Synechocystis sp. PCC6803, which can recognize light direction. We demonstrated that the dynamics was detected by fluorescent beads under an optical microscope and controlled by blue light that induces negative phototaxis; extension and retraction of T4P was activated at the forward side of lateral illumination to move away from the light source. Additionally, we directly visualized each pilus by fluorescent labeling, allowing us to quantify their asymmetric distribution. Finally, quantitative analyses of cell tracking indicated that T4P was generated uniformly within 0.2 min after blue-light exposure, and within the next 1 min the activation became asymmetric along the light axis to achieve directional cell motility; this process was mediated by the photo-sensing protein, PixD. This sequential process provides clues toward a general regulation mechanism of T4P system, which might be essentially common between archaella and other secretion apparatuses. PMID:28584115
Light emitting fabric technologies for photodynamic therapy.
Mordon, Serge; Cochrane, Cédric; Tylcz, Jean Baptiste; Betrouni, Nacim; Mortier, Laurent; Koncar, Vladan
2015-03-01
Photodynamic therapy (PDT) is considered to be a promising method for treating various types of cancer. A homogeneous and reproducible illumination during clinical PDT plays a determinant role in preventing under- or over-treatment. The development of flexible light sources would considerably improve the homogeneity of light delivery. The integration of optical fiber into flexible structures could offer an interesting alternative. This paper aims to describe different methods proposed to develop Side Emitting Optical Fibers (SEOF), and how these SEOF can be integrated in a flexible structure to improve light illumination of the skin during PDT. Four main techniques can be described: (i) light blanket integrating side-glowing optical fibers, (ii) light emitting panel composed of SEOF obtained by micro-perforations of the cladding, (iii) embroidery-based light emitting fabric, and (iv) woven-based light emitting fabric. Woven-based light emitting fabrics give the best performances: higher fluence rate, best homogeneity of light delivery, good flexibility. Copyright © 2014 Elsevier B.V. All rights reserved.
Design and Characterization of p-i-n Devices for Betavoltaic Microbatteries on Gallium Nitride
NASA Astrophysics Data System (ADS)
Khan, Muhammad Raziuddin A.
Betavoltaic microbatteries convert nuclear energy released as beta particles directly into electrical energy. These batteries are well suited for electrical applications such as micro-electro-mechanical systems (MEMS), implantable medical devices and sensors. Such devices are often located in hard to access places where long life, micro-size and lightweight are required. The working principle of a betavoltaic device is similar to a photovoltaic device; they differ only in that the electron hole pairs (EHPs) are generated in the device by electrons instead of photons. In this study, the performance of a betavoltaic device fabricated from gallium nitride (GaN) is investigated for beta particle energies equivalent to Tritium (3H) and Nickel-63 (N63) beta sources. GaN is an attractive choice for fabricating betavoltaic devices due to its wide band gap and radiation resistance. Another advantage GaN has is that it can be alloyed with aluminum (Al) to further increase the bandgap, resulting in a higher output power and increased efficiency. Betavoltaic devices were fabricated on p-i-n GaN structures grown by metalorganic chemical vapor deposition (MOCVD). The devices were characterized using current - voltage (IV) measurements without illumination (light or beta), using a laser driven light source, and under an electron beam. Dark IV measurements showed a turn on-voltage of ~ 3.4 V, specific-on-resistance of 15.1 m O-cm2, and a leakage current of 0.5 mA at -- 10 V. A clear photo-response was observed when IV curves were measured for these devices under a light source at a wavelength of 310 nm (4.0 eV). These devices were tested under an electron beam in order to evaluate their behavior as betavoltaic microbatteries without using radioactive materials. Output power of 70 nW and 640 nW with overall efficiencies of 1.2% and 4.0% were determined at the average energy emission of 3H (5.6 keV) and 63N (17 keV) respectively.
Direct Bandgap Group IV Materials
2016-01-21
devices. In this project, we have accomplished (a) direct bandgap group IV materials of GeSn, (b) GeSn-based planar light - emitting diode operated at near...devices of planar light emitting diode , detector and laser ” 6/12/2015 PI and Co-PI information: - Name of Principal Investigators: Prof. H. H. Cheng...IV materials of GeSn, (b) GeSn-based planar light - emitting diode operated at near infrared with direct emission, and (c) the first planar
Göksel, Meltem; Biyiklioglu, Zekeriya; Durmuş, Mahmut
2017-08-01
Two novel silicon(IV) phthalocyanines bearing 1,3-bis[3(dimethylamino)phenoxy]propan-2-ol or 1,3-bis[3(diethylamino)phenoxy]propan-2-ol groups at their axial positions were synthesized. These phthalocyanines were converted into their water soluble derivatives by the quaternization reaction with methyl iodide. The quaternized phthalocyanines show excellent solubility aqueous solutions without any aggregation which makes them potential photosensitizers for use in photodynamic therapy (PDT). For this reason, the photophysical and photochemical properties such as fluorescence quantum yields, lifetimes, singlet oxygen generation and photodegradation of both non-ionic (3 and 5) and quaternized cationic silicon(IV) phthalocyanines were investigated. Furthermore, the cytotoxicity of PDT was determined by colorimetric proliferation assay against to hepatocellular carcinoma (HuH-7) cancer cells. In this study, the cells were incubated with a novel water soluble silicon(IV) phthalocyanine derivatives and thereafter the cells were illuminated using broad-band incoherent light source.
Preparing the MAX IV storage rings for timing-based experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stråhlman, C., E-mail: Christian.Strahlman@maxlab.lu.se; Olsson, T., E-mail: Teresia.Olsson@maxlab.lu.se; Leemann, S. C.
2016-07-27
Time-resolved experimental techniques are increasingly abundant at storage ring facilities. Recent developments in accelerator technology and beamline instrumentation allow for simultaneous operation of high-intensity and timing-based experiments. The MAX IV facility is a state-of-the-art synchrotron light source in Lund, Sweden, that will come into operation in 2016. As many storage ring facilities are pursuing upgrade programs employing strong-focusing multibend achromats and passive harmonic cavities (HCs) in high-current operation, it is of broad interest to study the accelerator and instrumentation developments required to enable timing-based experiments at such machines. In particular, the use of hybrid filling modes combined with pulse pickingmore » by resonant excitation or pseudo single bunch has shown promising results. These methods can be combined with novel beamline instrumentation, such as choppers and instrument gating. In this paper we discuss how these techniques can be implemented and employed at MAX IV.« less
Design and characterization of GaN p-i-n diodes for betavoltaic devices
NASA Astrophysics Data System (ADS)
Khan, Muhammad R.; Smith, Joshua R.; Tompkins, Randy P.; Kelley, Stephen; Litz, Marc; Russo, John; Leathersich, Jeff; Shahedipour-Sandvik, Fatemeh (Shadi); Jones, Kenneth A.; Iliadis, Agis
2017-10-01
The performance of gallium nitride (GaN) p-i-n diodes were investigated for use as a betavoltaic device. Dark IV measurements showed a turn on-voltage of approximately 3.2 V, specific-on-resistance of 15.1 mΩ cm2 and a reverse leakage current of -0.14 mA/cm2 at -10 V. A clear photo-response was observed when IV curves were measured under a light source at a wavelength of 310 nm (4.0 eV). In addition, GaN p-i-n diodes were tested under an electron-beam in order to simulate common beta radiation sources ranging from that of 3H (5.6 keV average) to 63Ni (17 keV average). From this data, we estimated output powers of 53 nW and 750 nW with overall efficiencies of 0.96% and 4.4% for our device at incident electron energies of 5.6 keV and 17 keV corresponding to 3H and 63Ni beta sources respectively.
The MAX IV storage ring project
Tavares, Pedro F.; Leemann, Simon C.; Sjöström, Magnus; Andersson, Åke
2014-01-01
The MAX IV facility, currently under construction in Lund, Sweden, features two electron storage rings operated at 3 GeV and 1.5 GeV and optimized for the hard X-ray and soft X-ray/VUV spectral ranges, respectively. A 3 GeV linear accelerator serves as a full-energy injector into both rings as well as a driver for a short-pulse facility, in which undulators produce X-ray pulses as short as 100 fs. The 3 GeV ring employs a multibend achromat (MBA) lattice to achieve, in a relatively short circumference of 528 m, a bare lattice emittance of 0.33 nm rad, which reduces to 0.2 nm rad as insertion devices are added. The engineering implementation of the MBA lattice raises several technological problems. The large number of strong magnets per achromat calls for a compact design featuring small-gap combined-function magnets grouped into cells and sharing a common iron yoke. The small apertures lead to a low-conductance vacuum chamber design that relies on the chamber itself as a distributed copper absorber for the heat deposited by synchrotron radiation, while non-evaporable getter (NEG) coating provides for reduced photodesorption yields and distributed pumping. Finally, a low main frequency (100 MHz) is chosen for the RF system yielding long bunches, which are further elongated by passively operated third-harmonic Landau cavities, thus alleviating collective effects, both coherent (e.g. resistive wall instabilities) and incoherent (intrabeam scattering). In this paper, we focus on the MAX IV 3 GeV ring and present the lattice design as well as the engineering solutions to the challenges inherent to such a design. As the first realisation of a light source based on the MBA concept, the MAX IV 3 GeV ring offers an opportunity for validation of concepts that are likely to be essential ingredients of future diffraction-limited light sources. PMID:25177978
A Penning discharge source for extreme ultraviolet calibration
NASA Technical Reports Server (NTRS)
Finley, David S.; Jelinsky, Patrick; Bowyer, Stuart; Malina, Roger F.
1986-01-01
A Penning discharge lamp for use in the calibration of instruments and components for the extreme ultraviolet has been developed. This source is sufficiently light and compact to make it suitable for mounting on the movable slit assembly of a grazing incidence Rowland circle monochromator. Because this is a continuous discharge source, it is suitable for use with photon counting detectors. Line radiation is provided both by the gas and by atoms sputtered off the interchangeable metal cathodes. Usable lines are produced by species as highly ionized as Ne IV and Al V. The wavelength coverage provided is such that a good density of emission lines is available down to wavelengths as short as 100A. This source fills the gap between 100 and 300A, which is inadequately covered by the other available compact continuous radiation sources.
Report for 2011 from the Bordeaux IVS Analysis Center
NASA Technical Reports Server (NTRS)
Charlot, Patrick; Bellanger, Antoine; Bourda, Geraldine; Collioud, Arnaud; Baudry, Alain
2012-01-01
This report summarizes the activities of the Bordeaux IVS Analysis Center during the year 2011. The work focused on (i) regular analysis of the IVS-R1 and IVS-R4 sessions with the GINS software package; (ii) systematic VLBI imaging of the RDV sessions and calculation of the corresponding source structure index and compactness values; (iii) imaging of the sources observed during the 2009 International Year of Astronomy IVS observing session; and (iv) continuation of our VLBI observational program to identify optically-bright radio sources suitable for the link with the future Gaia frame. Also of importance is the enhancement of the IVS LiveWeb site which now comprises all IVS sessions back to 2003, allowing one to search past observations for session-specific information (e.g. sources or stations).
Studies of redox active silicalite-2 and the development of stable white-light phosphors
NASA Astrophysics Data System (ADS)
Lita, Adrian
Mn-silicalite-2 was synthesized at high pH using the molecular cluster, Mn12O12(O2CCH3)16 as a Mn Source. No precipitation of manganese hydroxide was observed with this cluster even with the use of tetrabutylammonium hydroxide as a templating agent. This synthetic approach resulted in the incorporation of up to 2.5 mol % Mn into the silicalite-2 with direct substitution into the framework verified by a linear relationship between unit cell volume and loading. The Mn is reduced to Mn(II) during hydrothermal synthesis and incorporated into the silicalite-2 framework during calcination at 500°C. Further calcination at 750°C does not affect the crystallinity but oxidizes essentially all of the Mn(II) to Mn(III). Cr(IV) substituted silicalite-2 was generated by reduction of Cr(VI)-silicalite-2 lattice sites at in a CO atmosphere. The reduction process, Reduction at high pressures was found to give almost complete conversion of the Cr(VI) sites to Cr(IV). As generated, the Cr(IV) sites do not reoxidize to Cr(VI) under ambient conditions or in the presence of oxidants under reaction conditions. We report the development of new class solid-state white-light phosphors based on stable nanoparticle-silica glass composites. These materials are made from the incorporating of CdSe nanoparticles into a silica Sol-gel solution. Once it gelled and aged the materials are calcined at 500°C under oxygen. The solid that results are robust with a bright white luminescence (20%) under UV excitation that gives virtually pure white light with coordinates of (0.34, 0.36) on the CIE 1931 chromaticity diagram and, more importantly, the emission envelope coincides nearly identically with the scotopic eye response function. The white-light phosphors have a scotopic/phtopic ratio of 2.56, indicating that these phosphors will be perceived as a particularly efficient illumination source in a dark environment thereby being more energy efficient. The emission comes from a distribution of nanoscale CdSe particles, with size-polydispersity brought on by calcination and subsequent fusing of nanoparticle agglomerates in the micropores of the silica xerogel. The silica matrix makes them exceedingly robust, with no changes in the emission properties observed for periods in excess of 18 months.
NASA Astrophysics Data System (ADS)
Lin, Jia-He; Zhang, Hong; Cheng, Xin-Lu; Miyamoto, Yoshiyuki
2017-07-01
Recently, single-layer group III monochalcogenides have attracted both theoretical and experimental interest at their potential applications in photonic devices, electronic devices, and solar energy conversion. Excited by this, we theoretically design two kinds of highly stable single-layer group IV-V (IV =Si ,Ge , and Sn; V =N and P) and group V-IV-III-VI (IV =Si ,Ge , and Sn; V =N and P; III =Al ,Ga , and In; VI =O and S) compounds with the same structures with single-layer group III monochalcogenides via first-principles simulations. By using accurate hybrid functional and quasiparticle methods, we show the single-layer group IV-V and group V-IV-III-VI are indirect bandgap semiconductors with their bandgaps and band edge positions conforming to the criteria of photocatalysts for water splitting. By applying a biaxial strain on single-layer group IV-V, single-layer group IV nitrides show a potential on mechanical sensors due to their bandgaps showing an almost linear response for strain. Furthermore, our calculations show that both single-layer group IV-V and group V-IV-III-VI have absorption from the visible light region to far-ultraviolet region, especially for single-layer SiN-AlO and SnN-InO, which have strong absorption in the visible light region, resulting in excellent potential for solar energy conversion and visible light photocatalytic water splitting. Our research provides valuable insight for finding more potential functional two-dimensional semiconductors applied in optoelectronics, solar energy conversion, and photocatalytic water splitting.
Zhang, Ye; Li, Si Zhen; Li, Lei; He, Ming Guang; Thomas, Ravi; Wang, Ning Li
2014-04-24
To estimate and compare the change in iris cross-sectional area (IA) and iris volume (IV) following physiologic and pharmacologic pupil dilation in primary angle closure suspects (PACS) and normal subjects. Anterior segment-optical coherence tomography (AS-OCT) measurements in light, dark, and following pharmacologic dilation were obtained on 186 PACS and 224 normal subjects examined during the 5-year follow-up of the Handan Eye Study. Iris cross-sectional area, IV, and other biometric parameters calculated using the Zhongshan angle assessment program in the right eyes of all subjects were analyzed. The mean IA and IV decreased in dark compared with light and after pharmacologic dilation in both PACS and normal eyes. This change was statistically significant in normal eyes: light versus pharmacologic dilation for IA (P = 0.038) and for IV, both light versus dark (P = 0.031) and light versus pharmacologic dilation (P = 0.012). A longer axial length (P = 0.028) and a greater change in pupil diameter (PD) (P < 0.001) were associated with a larger decrease of IA for the light to dark comparison. A diagnosis of normal eyes (P = 0.011), larger PD in dark (P = 0.001), and a larger change in PD (P = 0.001) were associated with a larger decrease of IV from light to dark. The differences in iris behavior between PACS and normal rural Chinese subjects following physiologic or pharmacologic pupillary dilation may help provide insights into the pathogenesis of angle closure. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Current-Voltage Characteristics of Nb2O5 nanoporous via light illumination
NASA Astrophysics Data System (ADS)
Samihah Khairir, Nur; Rani, Rozina Abdul; Fazlida Hanim Abdullah, Wan; Hafiz Mamat, Mohamad; Kadir, Rosmalini Abdul; Rusop, M.; Sabirin Zoolfakar, Ahmad
2018-03-01
This work discussed the effect of light on I-V characteristics of anodized niobium pentoxide (Nb2O5) which formed nanoporous structure film. The structure was synthesized by anodizing niobium foils in glycerol based solution with 10 wt% supplied by two different voltages, 5V and 10V. The anodized foils that contained Nb2O5 film were then annealed to obtain an orthorhombic phase for 30 minutes at 450°C. The metal contact used for I-V testing was platinum (Pt) and it was deposited using thermal evaporator at 30nm thickness. I-V tests were conducted under different condition; dark and illumination to study the effect of light on I-V characteristics of anodized nanoporous Nb2O5. Higher anodization voltage and longer anodization time resulted in higher pore dispersion and larger pore size causing the current to increase. The increase of conductivity in I-V behaviour of Nb2O5 device is also affected by the illumination test as higher light intensity caused space charge region width to increase, thus making it easier for electron transfer between energy band gap.
C IV λ1549 as an Eigenvector 1 Parameter for Active Galactic Nuclei
NASA Astrophysics Data System (ADS)
Sulentic, Jack W.; Bachev, Rumen; Marziani, Paola; Negrete, C. Alenka; Dultzin, Deborah
2007-09-01
We are exploring a spectroscopic unification for all types of broad-line emitting AGNs. The four-dimensional Eigenvector 1 (4DE1) parameter space organizes quasar diversity in a sequence primarily governed by Eddington ratio. This paper considers the role of C IV λ1549 measures as 4DE1 diagnostics. We use HST archival spectra for 130 sources with S/N high enough to permit reliable C IV λ1549 broad-component measures. We find a C IV λ1549BC profile blueshift that is strongly concentrated among (largely radio-quiet [RQ]) sources with FWHM(HβBC)<~4000 km s-1 (which we call Population A). Narrow-line Seyfert 1 (NLSy1; with FWHM Hβ<=2000 km s-1) sources belong to this population but do not emerge as a distinct class. The systematic blueshift, widely interpreted as arising in a disk wind/outflow, is not observed in broader line AGNs (including most radio-loud [RL] sources), which we call Population B. We find new correlations involving FWHM(C IV λ1549BC), C IV λ1549 line shift, and equivalent width only among Population A sources. Sulentic et al. suggested C IV λ1549 measures enhance an apparent dichotomy between sources with FWHM(HβBC) less and greater than 4000 km s-1, suggesting that it has more significance in the context of broad-line region structure than the more commonly discussed RL versus RQ dichotomy. Black hole masses computed from FWHM C IV λ1549BC for about 80 AGNs indicate that the C IV λ1549 width is a poor virial estimator. Comparison of mass estimates derived from HβBC and C IV λ1549 reveals that the latter show different and nonlinear offsets for Population A and B sources. A significant number of sources also show narrow-line C IV λ1549 emission that must be removed before C IV λ1549BC measures can be made and interpreted effectively. We present a recipe for C IV λ1549 narrow-component extraction.
Photoactivation of Diiodido-Pt(IV) Complexes Coupled to Upconverting Nanoparticles.
Perfahl, Stefanie; Natile, Marta M; Mohamad, Heba S; Helm, Christiane A; Schulzke, Carola; Natile, Giovanni; Bednarski, Patrick J
2016-07-05
The preparation, characterization, and surface modification of upconverting lanthanide-doped hexagonal NaGdF4 nanocrystals attached to light sensitive diiodido-Pt(IV) complexes is presented. The evaluation for photoactivation and cytotoxicity of the novel carboxylated diiodido-Pt(IV) cytotoxic prodrugs by near-infrared (NIR) light (λ = 980 nm) is also reported. We attempted two different strategies for attachment of light-sensitive diiodido-Pt(IV) complexes to Yb,Er- and Yb,Tm-doped β-NaGdF4 upconverting nanoparticles (UCNPs) in order to provide nanohybrids, which offer unique opportunities for selective drug activation within the tumor cells and subsequent spatiotemporal controlled drug release by NIR-to-visible light-upconversion: (A) covalent attachment of the Pt(IV) complex via amide bond formation and (B) carboxylate exchange of oleate on the surface of the UCNPs with diiodido-Pt(IV) carboxylato complexes. Initial feasibility studies showed that NIR applied by a 980 nm laser had only a slight effect on the stability of the various diiodido-Pt(IV) complexes, but when UCNPs were present more rapid loss of the ligand-metal-charge transfer (LMCT) bands of the diiodido-Pt(IV) complexes was observed. Furthermore, Pt released from the Pt(IV) complexes platinated calf-thymus DNA (ct-DNA) more rapidly when NIR was applied compared to dark controls. Of the two attachment strategies, method A with the covalently attached diiodido-Pt(IV) carboxylates via amide bond formation proved to be the most effective method for generating UCNPs that release Pt when irradiated with NIR; the released Pt was also able to bind irreversibly to calf thymus DNA. Nonetheless, only ca. 20% of the Pt on the surface of the UCNPs was in the Pt(IV) oxidation state, the rest was Pt(II), indicating chemical reduction of the diiodido-Pt(IV) prodrug by the UCNPs. Cytotoxicity studies with the various UCNP-Pt conjugates and constructs, tested on human leukemia HL60 cells in culture, indicated a substantial increase in cytotoxicity when modified UCNPs were combined with five rounds of 30 min irradiation with NIR compared to dark controls, but NIR alone also had a significant cytotoxic effect at this duration.
Intrinsic melanin and hemoglobin colour components for skin lesion malignancy detection.
Madooei, Ali; Drew, Mark S; Sadeghi, Maryam; Atkins, M Stella
2012-01-01
In this paper we propose a new log-chromaticity 2-D colour space, an extension of previous approaches, which succeeds in removing confounding factors from dermoscopic images: (i) the effects of the particular camera characteristics for the camera system used in forming RGB images; (ii) the colour of the light used in the dermoscope; (iii) shading induced by imaging non-flat skin surfaces; (iv) and light intensity, removing the effect of light-intensity falloff toward the edges of the dermoscopic image. In the context of a blind source separation of the underlying colour, we arrive at intrinsic melanin and hemoglobin images, whose properties are then used in supervised learning to achieve excellent malignant vs. benign skin lesion classification. In addition, we propose using the geometric-mean of colour for skin lesion segmentation based on simple grey-level thresholding, with results outperforming the state of the art.
Electroformed silicon nitride based light emitting memory device
NASA Astrophysics Data System (ADS)
Anutgan, Tamila; Anutgan, Mustafa; Atilgan, Ismail; Katircioglu, Bayram
2017-07-01
The resistive memory switching effect of an electroformed nanocrystal silicon nitride thin film light emitting diode (LED) is demonstrated. For this purpose, current-voltage (I-V) characteristics of the diode were systematically scanned, paying particular attention to the sequence of the measurements. It was found that when the voltage polarity was changed from reverse to forward, the previously measured reverse I-V behavior was remembered until some critical forward bias voltage. Beyond this critical voltage, the I-V curve returns to its original state instantaneously, and light emission switches from the OFF state to the ON state. The kinetics of this switching mechanism was studied for different forward bias stresses by measuring the corresponding time at which the switching occurs. Finally, the switching of resistance and light emission states was discussed via energy band structure of the electroformed LED.
Effect of a novel low-energy pulsed-light device for home-use hair removal.
Alster, Tina S; Tanzi, Elizabeth L
2009-03-01
Removal of unwanted hair is the most popular skin treatment worldwide. Over the past decade, various lasers and light sources for epilation have been advocated for use in an office setting, although most people continue to treat unwanted hair with a variety of temporary physical methods (e.g., waxing, shaving) in a home setting, presumably due to cost and convenience factors. To evaluate the safety and efficacy of a low-energy pulsed-light device intended for home-use hair removal. Twenty women (skin phototypes I-IV) with dark terminal hair in nonfacial sites (axilla, forearms, inguinal region, legs) self-administered three treatments at 2-week intervals using a handheld intense-pulsed-light device. Matched untreated skin sites were also studied. Hair counts and clinical photographs were obtained pretreatment and at 1, 3, and 6 months after the third treatment. Side effects and patient satisfaction scores were recorded. All patients showed a positive clinical response to treatment, with reduction of unwanted hair. No reduction of hair was noted in untreated matched areas. Hair counts were reduced 37.8% to 53.6% 6 months after the three treatments. Skin region influenced clinical response, with lower legs exhibiting greater hair reduction than arms and inguinal and axillary areas. Mild erythema was experienced in 25% of patients, but no other side effects or complications were encountered. Patient satisfaction scores were high, with all patients stating that they would purchase the device for future home use. CONCLUSIONS Low-energy pulsed light can be applied safely and effectively for at-home hair removal in a variety of nonfacial locations and skin phototypes I-IV.
Barker, C.E.; Pawlewicz, M.; Cobabe, E.A.
2001-01-01
A transect of three holes drilled across the Blake Nose, western North Atlantic Ocean, retrieved cores of black shale facies related to the Albian Oceanic Anoxic Events (OAE) lb and ld. Sedimentary organic matter (SOM) recovered from Ocean Drilling Program Hole 1049A from the eastern end of the transect showed that before black shale facies deposition organic matter preservation was a Type III-IV SOM. Petrography reveals that this SOM is composed mostly of degraded algal debris, amorphous SOM and a minor component of Type III-IV terrestrial SOM, mostly detroinertinite. When black shale facies deposition commenced, the geochemical character of the SOM changed from a relatively oxygen-rich Type III-IV to relatively hydrogen-rich Type II. Petrography, biomarker and organic carbon isotopic data indicate marine and terrestrial SOM sources that do not appear to change during the transition from light-grey calcareous ooze to the black shale facies. Black shale subfacies layers alternate from laminated to homogeneous. Some of the laminated and the poorly laminated to homogeneous layers are organic carbon and hydrogen rich as well, suggesting that at least two SOM depositional processes are influencing the black shale facies. The laminated beds reflect deposition in a low sedimentation rate (6m Ma-1) environment with SOM derived mostly from gravity settling from the overlying water into sometimes dysoxic bottom water. The source of this high hydrogen content SOM is problematic because before black shale deposition, the marine SOM supplied to the site is geochemically a Type III-IV. A clue to the source of the H-rich SOM may be the interlayering of relatively homogeneous ooze layers that have a widely variable SOM content and quality. These relatively thick, sometimes subtly graded, sediment layers are thought to be deposited from a Type II SOM-enriched sediment suspension generated by turbidities or direct turbidite deposition.
First scattered-light image of the debris disk around HD 131835 with the Gemini Planet Imager
Hung, Li -Wei; Duchêne, Gaspard; Arriaga, Pauline; ...
2015-12-09
Here, we present the first scattered-light image of the debris disk around HD 131835 in the H band using the Gemini Planet Imager. HD 131835 is a ~15 Myr old A2IV star at a distance of ~120 pc in the Sco-Cen OB association. We detect the disk only in polarized light and place an upper limit on the peak total intensity. No point sources resembling exoplanets were identified. Compared to its mid-infrared thermal emission, in scattered light the disk shows similar orientation but different morphology. The scattered-light disk extends from ~75 to ~210 AU in the disk plane with roughlymore » flat surface density. Our Monte Carlo radiative transfer model can describe the observations with a model disk composed of a mixture of silicates and amorphous carbon. In addition to the obvious brightness asymmetry due to stronger forward scattering, we discover a weak brightness asymmetry along the major axis, with the northeast side being 1.3 times brighter than the southwest side at a 3σ level.« less
FIRST SCATTERED-LIGHT IMAGE OF THE DEBRIS DISK AROUND HD 131835 WITH THE GEMINI PLANET IMAGER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hung, Li-Wei; Arriaga, Pauline; Fitzgerald, Michael P.
2015-12-10
We present the first scattered-light image of the debris disk around HD 131835 in the H band using the Gemini Planet Imager. HD 131835 is a ∼15 Myr old A2IV star at a distance of ∼120 pc in the Sco-Cen OB association. We detect the disk only in polarized light and place an upper limit on the peak total intensity. No point sources resembling exoplanets were identified. Compared to its mid-infrared thermal emission, in scattered light the disk shows similar orientation but different morphology. The scattered-light disk extends from ∼75 to ∼210 AU in the disk plane with roughly flatmore » surface density. Our Monte Carlo radiative transfer model can describe the observations with a model disk composed of a mixture of silicates and amorphous carbon. In addition to the obvious brightness asymmetry due to stronger forward scattering, we discover a weak brightness asymmetry along the major axis, with the northeast side being 1.3 times brighter than the southwest side at a 3σ level.« less
Gankanda, Aruni; Coddens, Ellen M; Zhang, Yaping; Cwiertny, David M; Grassian, Vicki H
2016-12-08
Recent atmospheric field and modeling studies have highlighted a lack of understanding of the processes responsible for high levels of sulfate aerosol in the atmosphere, ultimately arising from a dearth of experimental data on such processes. Here we investigated the effect of temperature and simulated solar radiation on the catalytic oxidation of S(iv) to S(vi) (i.e., sulfite to sulfate) in aqueous suspensions of several metal-containing, atmospherically relevant particles including coal fly ash (FA), Arizona test dust (ATD) and an iron oxide (γ-Fe 2 O 3 ). The effect of temperature and light on S(iv) oxidation was found to be very different for these three samples. For example, in the presence of FA and γ-Fe 2 O 3 the temporal evolution of dissolved Fe(ii) (formed via reductive particle dissolution) correlated with S(iv) oxidation. Accordingly, we propose that S(iv) oxidation in most of these systems initially occurs primarily at the particle surface (i.e., a heterogeneous reaction pathway), although a solution-phase (i.e., homogeneous) catalytic pathway also contributes over later timescales due to the formation and accumulation of dissolved Fe(iii) (generated via oxidation of dissolved Fe(ii) by O 2 ). It is likely that the homogeneous reaction pathway is operative at initial times in the presence of γ-Fe 2 O 3 at 25 °C. In contrast, S(iv) oxidation in the presence of ATD appears to proceed entirely via a heterogeneous reaction, which notably does not lead to any iron dissolution. In fact, the greater overall rate of S(iv) loss in the presence of ATD compared to FA and γ-Fe 2 O 3 suggests that other factors, including greater adsorption of sulfite, transition metal ion (TMI) catalysis by other metal ions (e.g., Ti), or different species of iron in ATD, play a role. Overall these studies suggest that the rate, extent and products of atmospheric S(iv) oxidation can be highly variable and dependent upon the nature of aerosol sources and ambient conditions (e.g., temperature and irradiance). Ultimately, such complexity precludes simple, broadly generalized schemes for this reaction when modeling atmospheric processes involving diverse components of different mineral dust aerosol as well as other metal-containing aerosol.
NASA Astrophysics Data System (ADS)
Wang, Jiao; Xue, Jinhua; Xiao, Xilin; Xu, Li; Jiang, Min; Peng, Pengcheng; Liao, Lifu
2017-12-01
The coordination reaction of thorium (IV) with a ditopic bidentate ligand to form supramolecular polymer was studied by resonance light scattering (RLS) spectra, second-order scattering (SOS) spectra and frequency-doubling scattering (FDS) spectra, respectively. The ditopic bidentate ligand is isophthalaldehyde-tetrapyrrole (IPTP). It was synthesized through a condensation reaction of isophthalaldehyde with pyrrole. The formation of supramolecular polymer results in remarkable intensity enhancements of the three light scattering signals. The maximum scattering wavelengths of RLS, FDS and SOS were 290, 568 and 340 nm, respectively. The reaction was used to establish new light scattering methods for the determination of thorium (IV) by using IPTP as probe. Under optimum conditions, the intensity enhancements of RLS, SOS and FDS were directly proportional to the concentration of thorium (IV) in the ranges of 0.01 to 1.2 μg mL- 1, 0.05 to 1.2 μg mL- 1 and 0.05 to 1.2 μg mL- 1, respectively. The detection limits were 0.003 μg mL- 1, 0.012 μg mL- 1 and 0.021 μg mL- 1, respectively. The methods were suitable for analyzing thorium (IV) in actual samples. The results show acceptable recoveries and precision compared with a reference method.
NASA Astrophysics Data System (ADS)
Tsuchida, Akihiro; Shimamura, Takeshi; Sawada, Seiya; Sato, Susumu; Serpone, Nick; Horikoshi, Satoshi
2018-06-01
A microwave-inspired device that generates stable in-liquid plasma (LP) in aqueous media and emits narrow light emission lines at 280-320 nm, 660 nm and 780 nm is examined as a light source capable of driving photochemical reactions and advanced oxidation processes in wastewater treatments. The microwave-driven lighting efficiency was improved by decompressing the inside of the reaction vessel, which resulted in lowering the incident power of the microwaves and suppressed the deterioration of the microwave irradiation antenna. This protocol made it possible to generate continuous stable plasma in water. Evaluation of the LP device was carried out by revisiting the decomposition of 1,4-dioxane in aqueous media against the use of such other conventional water treatment processes as (i) UV irradiation alone, (ii) TiO2-assisted photocatalysis with UV irradiation (UV/TiO2), (iii) oxidation with sodium hypochlorite (NaClO), and (iv) UV-assisted decomposition in the presence of NaClO (UV/NaClO). The in-liquid plasma technique proved superior to these four other methods. The influence of pH on the LP protocol was ascertained through experiments in acidified (HCl and H2SO4) and alkaline (NaOH and KOH) aqueous media. Except for H2SO4, decomposition of 1,4-dioxane was enhanced in both acidic and alkaline media.
TOWARD THE DEVELOPMENT OF A CONSENSUS MATERIALS DATABASE FOR PRESSURE TECHNOLGY APPLICATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swindeman, Robert W; Ren, Weiju
The ASME construction code books specify materials and fabrication procedures that are acceptable for pressure technology applications. However, with few exceptions, the materials properties provided in the ASME code books provide no statistics or other information pertaining to material variability. Such information is central to the prediction and prevention of failure events. Many sources of materials data exist that provide variability information but such sources do not necessarily represent a consensus of experts with respect to the reported trends that are represented. Such a need has been identified by the ASME Standards Technology, LLC and initial steps have been takenmore » to address these needs: however, these steps are limited to project-specific applications only, such as the joint DOE-ASME project on materials for Generation IV nuclear reactors. In contrast to light-water reactor technology, the experience base for the Generation IV nuclear reactors is somewhat lacking and heavy reliance must be placed on model development and predictive capability. The database for model development is being assembled and includes existing code alloys such as alloy 800H and 9Cr-1Mo-V steel. Ownership and use rights are potential barriers that must be addressed.« less
An Analysis of Sources of Technological Change in Efficiency Improvement of Fluorescent Lamp Systems
NASA Astrophysics Data System (ADS)
Imanaka, Takeo
In Japan, energy efficient fluorescent lamp systems which use “rare-earth phosphors” and “electronic ballasts” have shown rapid diffusion since 1990s. This report investigated sources of technological change in the efficiency improvement of fluorescent lamp systems: (i) Fluorescent lamp and luminaires have been under steady technological development for getting more energy efficient lighting and the concepts to achieve high efficiency had been found in such activities; however, it took long time until they realized and become widely used; (ii) Electronic ballasts and rare-earth phosphors add fluorescent lamp systems not only energy efficiency but also various values such as compactness, lightweight, higher output, and better color rendering properties, which have also been expected and have induced research and development (R&D) (iii) Affordable electronic ballasts are realized by the new technology “power MOSFET” which is based on IC technologies and has been developed for large markets of information and communication technologies and mobile devices; and (iv) Rare-earth phosphors became available after rare-earth industries developed for the purpose of supplying rare-earth phosphors for color television. In terms of sources of technological change, (i) corresponds to “R&D” aiming at the particular purpose i.e. energy efficiency in this case, on the other hand, (ii), (iii), and (iv) correspond to “spillovers” from activities aiming at other purposes. This case exhibits an actual example in which “spillovers” were the critical sources of technological change in energy technology.
Report for 2012 from the Bordeaux IVS Analysis Center
NASA Technical Reports Server (NTRS)
Charlot, Patrick; Bellanger, Antoine; Bouffet, Romuald; Bourda, Geraldine; Collioud, Arnaud; Baudry, Alain
2013-01-01
This report summarizes the activities of the Bordeaux IVS Analysis Center during the year 2012. The work focused on (i) regular analysis of the IVS-R1 and IVS-R4 sessions with the GINS software package; (ii) systematic VLBI imaging of the RDV sessions and calculation of the corresponding source structure index and compactness values; (iii) investigation of the correlation between astrometric position instabilities and source structure variations; and (iv) continuation of our VLBI observational program to identify optically-bright radio sources suitable for the link with the future Gaia frame. Also of importance is the 11th European VLBI Network Symposium, which we organized last October in Bordeaux and which drew much attention from the European and International VLBI communities.
Titania may produce abiotic oxygen atmospheres on habitable exoplanets
Narita, Norio; Enomoto, Takafumi; Masaoka, Shigeyuki; Kusakabe, Nobuhiko
2015-01-01
The search for habitable exoplanets in the Universe is actively ongoing in the field of astronomy. The biggest future milestone is to determine whether life exists on such habitable exoplanets. In that context, oxygen in the atmosphere has been considered strong evidence for the presence of photosynthetic organisms. In this paper, we show that a previously unconsidered photochemical mechanism by titanium (IV) oxide (titania) can produce abiotic oxygen from liquid water under near ultraviolet (NUV) lights on the surface of exoplanets. Titania works as a photocatalyst to dissociate liquid water in this process. This mechanism offers a different source of a possibility of abiotic oxygen in atmospheres of exoplanets from previously considered photodissociation of water vapor in upper atmospheres by extreme ultraviolet (XUV) light. Our order-of-magnitude estimation shows that possible amounts of oxygen produced by this abiotic mechanism can be comparable with or even more than that in the atmosphere of the current Earth, depending on the amount of active surface area for this mechanism. We conclude that titania may act as a potential source of false signs of life on habitable exoplanets. PMID:26354078
Titania may produce abiotic oxygen atmospheres on habitable exoplanets.
Narita, Norio; Enomoto, Takafumi; Masaoka, Shigeyuki; Kusakabe, Nobuhiko
2015-09-10
The search for habitable exoplanets in the Universe is actively ongoing in the field of astronomy. The biggest future milestone is to determine whether life exists on such habitable exoplanets. In that context, oxygen in the atmosphere has been considered strong evidence for the presence of photosynthetic organisms. In this paper, we show that a previously unconsidered photochemical mechanism by titanium (IV) oxide (titania) can produce abiotic oxygen from liquid water under near ultraviolet (NUV) lights on the surface of exoplanets. Titania works as a photocatalyst to dissociate liquid water in this process. This mechanism offers a different source of a possibility of abiotic oxygen in atmospheres of exoplanets from previously considered photodissociation of water vapor in upper atmospheres by extreme ultraviolet (XUV) light. Our order-of-magnitude estimation shows that possible amounts of oxygen produced by this abiotic mechanism can be comparable with or even more than that in the atmosphere of the current Earth, depending on the amount of active surface area for this mechanism. We conclude that titania may act as a potential source of false signs of life on habitable exoplanets.
Adding source positions to the IVS Combination
NASA Astrophysics Data System (ADS)
Bachmann, S.; Thaller, D.
2016-12-01
Simultaneous estimation of source positions, Earth orientation parameters (EOPs) and station positions in one common adjustment is crucial for a consistent generation of celestial and terrestrial reference frame (CRF and TRF, respectively). VLBI is the only technique to guarantee this consistency. Previous publications showed that the VLBI intra-technique combination could improve the quality of the EOPs and station coordinates compared to the individual contributions. By now, the combination of EOP and station coordinates is well established within the IVS and in combination with other space geodetic techniques (e.g. inter-technique combined TRF like the ITRF). Most of the contributing IVS Analysis Centers (AC) now provide source positions as a third parameter type (besides EOP and station coordinates), which have not been used for an operational combined solution yet. A strategy for the combination of source positions has been developed and integrated into the routine IVS combination. Investigations are carried out to compare the source positions derived from different IVS ACs with the combined estimates to verify whether the source positions are improved by the combination, as it has been proven for EOP and station coordinates. Furthermore, global solutions of source positions, i.e., so-called catalogues describing a CRF, are generated consistently with the TRF similar to the IVS operational combined quarterly solution. The combined solutions of the source positions time series and the consistently generated TRF and CRF are compared internally to the individual solutions of the ACs as well as to external CRF catalogues and TRFs. Additionally, comparisons of EOPs based on different CRF solutions are presented as an outlook for consistent EOP, CRF and TRF realizations.
Physical behaviour of anthropogenic light propagation into the nocturnal environment
Aubé, Martin
2015-01-01
Propagation of artificial light at night (ALAN) in the environment is now known to have non negligible consequences on fauna, flora and human health. These consequences depend on light levels and their spectral power distributions, which in turn rely on the efficiency of various physical processes involved in the radiative transfer of this light into the atmosphere and its interactions with the built and natural environment. ALAN can affect the living organisms by direct lighting and indirect lighting (scattered by the sky and clouds and/or reflected by local surfaces). This paper mainly focuses on the behaviour of the indirect light scattered under clear sky conditions. Various interaction processes between anthropogenic light sources and the natural environment are discussed. This work mostly relies on a sensitivity analysis conducted with the light pollution radiative transfer model, Illumina (Aubé et al. 2005 Light pollution modelling and detection in a heterogeneous environment: toward a night-time aerosol optical depth retrieval method. In Proc. SPIE 2005, vol. 5890, San Diego, California, USA). More specifically, the impact of (i) the molecular and aerosol scattering and absorption, (ii) the second order of scattering, (iii) the topography and obstacle blocking, (iv) the ground reflectance and (v) the spectrum of light devices and their angular emission functions are examined. This analysis considers different behaviour as a function of the distance from the city centre, along with different zenith viewing angles in the principal plane. PMID:25780231
Physical behaviour of anthropogenic light propagation into the nocturnal environment.
Aubé, Martin
2015-05-05
Propagation of artificial light at night (ALAN) in the environment is now known to have non negligible consequences on fauna, flora and human health. These consequences depend on light levels and their spectral power distributions, which in turn rely on the efficiency of various physical processes involved in the radiative transfer of this light into the atmosphere and its interactions with the built and natural environment. ALAN can affect the living organisms by direct lighting and indirect lighting (scattered by the sky and clouds and/or reflected by local surfaces). This paper mainly focuses on the behaviour of the indirect light scattered under clear sky conditions. Various interaction processes between anthropogenic light sources and the natural environment are discussed. This work mostly relies on a sensitivity analysis conducted with the light pollution radiative transfer model, Illumina (Aubé et al. 2005 Light pollution modelling and detection in a heterogeneous environment: toward a night-time aerosol optical depth retrieval method. In Proc. SPIE 2005, vol. 5890, San Diego, California, USA). More specifically, the impact of (i) the molecular and aerosol scattering and absorption, (ii) the second order of scattering, (iii) the topography and obstacle blocking, (iv) the ground reflectance and (v) the spectrum of light devices and their angular emission functions are examined. This analysis considers different behaviour as a function of the distance from the city centre, along with different zenith viewing angles in the principal plane. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Pinhas, Alexander; Dubow, Michael; Shah, Nishit; Chui, Toco Y.; Scoles, Drew; Sulai, Yusufu N.; Weitz, Rishard; Walsh, Joseph B.; Carroll, Joseph; Dubra, Alfredo; Rosen, Richard B.
2013-01-01
The adaptive optics scanning light ophthalmoscope (AOSLO) allows visualization of microscopic structures of the human retina in vivo. In this work, we demonstrate its application in combination with oral and intravenous (IV) fluorescein angiography (FA) to the in vivo visualization of the human retinal microvasculature. Ten healthy subjects ages 20 to 38 years were imaged using oral (7 and/or 20 mg/kg) and/or IV (500 mg) fluorescein. In agreement with current literature, there were no adverse effects among the patients receiving oral fluorescein while one patient receiving IV fluorescein experienced some nausea and heaving. We determined that all retinal capillary beds can be imaged using clinically accepted fluorescein dosages and safe light levels according to the ANSI Z136.1-2000 maximum permissible exposure. As expected, the 20 mg/kg oral dose showed higher image intensity for a longer period of time than did the 7 mg/kg oral and the 500 mg IV doses. The increased resolution of AOSLO FA, compared to conventional FA, offers great opportunity for studying physiological and pathological vascular processes. PMID:24009994
The BALDER Beamline at the MAX IV Laboratory
NASA Astrophysics Data System (ADS)
Klementiev, K.; Norén, K.; Carlson, S.; Sigfridsson Clauss, K. G. V.; Persson, I.
2016-05-01
X-ray absorption spectroscopy (XAS) includes well-established methods to study the local structure around the absorbing element - extended X-ray absorption fine structure (EXAFS), and the effective oxidation number or to quantitatively determine the speciation of an element in a complex matrix - X-ray absorption near-edge structure (XANES). The increased brilliance and intensities available at the new generation of synchrotron light sources makes it possible to study, in-situ and in-operando, much more dilute systems with relevance for natural systems, as well as the micro-scale variability and dynamics of chemical reactions on the millisecond time-scale. The design of the BALDER beamline at the MAX IV Laboratory 3 GeV ring has focused on a high flux of photons in a wide energy range, 2.4-40 keV, where the K-edge is covered for the elements S to La, and the L 3-edge for all elements heavier than Sb. The overall design of the beamline will allow large flexibility in energy range, beam size and data collection time. The other focus of the beamline design is the possibility to perform multi-technique analyses on samples. Development of sample environment requires focus on implementation of auxiliary methods in such a way that techniques like Fourier transform infrared (FTIR) spectroscopy, UV-Raman spectroscopy, X-ray diffraction and/or mass spectrometry can be performed simultaneously as the XAS study. It will be a flexible system where different instruments can be plugged in and out depending on the needs for the particular investigation. Many research areas will benefit from the properties of the wiggler based light source and the capabilities to perform in-situ and in-operando measurements, for example environmental and geochemical sciences, nuclear chemistry, catalysis, materials sciences, and cultural heritage.
NASA Astrophysics Data System (ADS)
Pura, J. L.; Anaya, J.; Souto, J.; Prieto, A. C.; Rodríguez, A.; Rodríguez, T.; Periwal, P.; Baron, T.; Jiménez, J.
2018-03-01
Semiconductor nanowires (NWs) are the building blocks of future nanoelectronic devices. Furthermore, their large refractive index and reduced dimension make them suitable for nanophotonics. The study of the interaction between nanowires and visible light reveals resonances that promise light absorption/scattering engineering for photonic applications. Micro-Raman spectroscopy has been used as a characterization tool for semiconductor nanowires. The light/nanowire interaction can be experimentally assessed through the micro-Raman spectra of individual nanowires. As compared to both metallic and dielectric nanowires, semiconductor nanowires add additional tools for photon engineering. In particular, one can grow heterostructured nanowires, both axial and radial, and also one could modulate the doping level and the surface condition among other factors than can affect the light/NW interaction. We present herein a study of the optical response of group IV semiconductor nanowires to visible photons. The study is experimentally carried out through micro-Raman spectroscopy of different group IV nanowires, both homogeneous and axially heterostructured (SiGe/Si). The results are analyzed in terms of the electromagnetic modelling of the light/nanowire interaction using finite element methods. The presence of axial heterostructures is shown to produce electromagnetic resonances promising new photon engineering capabilities of semiconductor nanowires.
Potential for a Near Term Very Low Energy Antiproton Source at Brookhaven National Laboratory.
1989-04-01
9 Table III-1: Cost Summary . . . . * . . .. . * 10 IV. Lattice and Stretcher Properties . . . . . . .............. 11 Fig. IV-1 Cell... lattice functions . . . . . . . . . . 12 Fig. IV-2 Insertion region lattice . . . . . . . . . 12 Fig. IV-3 Superperiod lattice functions . . . . . . 12...8217 * . . . 13 Table IV-Ib Parameters after lattice matching . . . . 13 Table IV-lc Components specification. . . 13 Table IV-2 Random multipoles. .. . . .. 15
NASA Astrophysics Data System (ADS)
Sardar, Shahid; Xu, Xin; Xu, Long-Quan; Zhu, Lin-Fan
2018-02-01
In this paper we present photoionization cross-sections of the ground and excited states of Li-like carbon (C IV) in the framework of fully relativistic R-matrix formalism as implemented in Dirac atomic R-matrix code. For target wavefunctions expansion, Multiconfiguration Dirac Hartree Fock calculations are performed for the lowest 17 target states of He-like carbon (C V) arising from 1s2 and 1snl, with n = 2, 3 and l = s, p, d configurations. Our target energy levels and transition parameters belonging to these levels are ascertained to be in excellent agreement with the experimental and the well-established theoretical results. We use the principle of detailed balance to get the photorecombination (PR) cross-sections of the ground state of C V. Both photoionization and PR cross-sections manifest important KLL and KLM resonance structures which are in very good agreement with the accurate measurements at Advanced Light Source (ion photon end beam station) and CRYRING (synchrotron storage ring).
Pennington, Malinda L.; Cullinan, Douglas; Southern, Louise B.
2014-01-01
In light of the steady rise in the prevalence of students with autism, this study examined the definition of autism published by state education agencies (SEAs), as well as SEA-indicated evaluation procedures for determining student qualification for autism. We compared components of each SEA definition to aspects of autism from two authoritative sources: Diagnostic and Statistical Manual of Mental Disorders (DSM-IV-TR) and Individuals with Disabilities Education Improvement Act (IDEA-2004). We also compared SEA-indicated evaluation procedures across SEAs to evaluation procedures noted in IDEA-2004. Results indicated that many more SEA definitions incorporate IDEA-2004 features than DSM-IV-TR features. However, despite similar foundations, SEA definitions of autism displayed considerable variability. Evaluation procedures were found to vary even more across SEAs. Moreover, within any particular SEA there often was little concordance between the definition (what autism is) and evaluation procedures (how autism is recognized). Recommendations for state and federal policy changes are discussed. PMID:24987527
Ma, Li; Xiang, Lei-Hong; Yu, Bo; Yin, Rui; Chen, Lei; Wu, Yan; Tan, Zhi-Jian; Liu, Yong-Bin; Tian, Hong-Qing; Li, Hui-Zhong; Lin, Tong; Wang, Xiu-Li; Li, Yuan-Hong; Wang, Wei-Zheng; Yang, Hui-Lan; Lai, Wei
2013-12-01
To investigate the efficacy and safety of low-concentration 5-aminolevulinic acid photodynamic therapy (ALA-PDT) in the treatment of different severity of acne vulgaris and optimize the treatment regimen. A self-controlled multicenter clinical trial was carried out in 15 centers throughout China. A total of 397 acne patients of grade II-IV received 3- or 4-session PDT treatment. 5% ALA gel was applied topically to acne lesions for 1h incubation. The lesions were irradiated by a LED light of 633 nm at dose levels of 96-120 J/cm(2). Clinical assessment was conducted before and after every treatment up to 8 weeks. The effective rate overall and of grade II, III and IV are 82.1%, 71.6%, 79.6% and 88.2%, respectively. The effective rate rises significantly proportionally to the severity of acne (P<0.01). No significant differences are found in the efficacy between patients received 3-session and 4-session PDT treatments (P>0.05). The count of inflammatory and non-inflammatory acne lesions gradually decrease after each treatment (P<0.01) and during the 8-week follow up (P<0.01 or P<0.05). Maximum efficacy is obtained at 8 weeks after the treatment completion. A low-dose topical ALA-PDT regimen using 5% ALA, 1h incubation and red light source of 3 treatment sessions is suggested as optimal scheme for the treatment of different severity of acne vulgaris in Chinese patients. Superior efficacy is found in severe cystic acne of grade IV with mild side effects. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Xiao-Wen; Zhou, Mei-Fu; Beaudoin, Georges; Gao, Jian-Feng; Qi, Liang; Lyu, Chuan
2018-01-01
The Yamansu Fe deposit (32 Mt at 51% Fe) in the Eastern Tianshan Orogenic Belt of NW China is hosted in early Carboniferous volcano-sedimentary rocks and spatially associated with skarn. The paragenetic sequence includes garnet-diopside (I), magnetite (II), hydrous silicate-sulfide (III), and calcite-quartz (IV) stages. Pyrite associated with magnetite has a Re-Os isochron age of 322 ± 7 Ma, which represents the timing of pyrite and, by inference, magnetite mineralization. Pyrite has δ 34SVCDT values of - 2.2 to + 2.9‰, yielding δ 34SH2S values of - 3.1 to 2‰, indicating the derivation of sulfur from a magmatic source. Calcite from stages II and IV has δ 13CVPDB values from - 2.5 to - 1.2‰, and - 1.1 to 1.1‰, and δ 18OVSMOW values from 11.8 to 12.0‰ and - 7.7 to - 5.2‰, respectively. Calculated δ 13C values of fluid CO2 and water δ 18O values indicate that stage II hydrothermal fluids were derived from magmatic rocks and that meteoric water mixed with the hydrothermal fluids in stage IV. Some ores contain magnetite with obvious chemical zoning composed of dark and light domains in BSE images. Dark domains have higher Mg, Al, Ca, Mn, and Ti but lower Fe and Cr contents than light domains. The chemical zoning resulted from a fluctuating fluid composition and/or physicochemical conditions (oscillatory zoning), or dissolution-precipitation (irregular zoning) via infiltration of magmatic-hydrothermal fluids diluted by late meteoric water. Iron was mainly derived from fluids similar to that in skarn deposits.
Nagaya, Tadanobu; Sato, Kazuhide; Harada, Toshiko; Nakamura, Yuko; Choyke, Peter L.; Kobayashi, Hisataka
2015-01-01
Aim Triple-negative breast cancer (TNBC) is considered one of the most aggressive subtypes of breast cancer. Near infrared photoimmunotherapy (NIR-PIT) is a cancer treatment that employs an antibody-photosensitizer conjugate (APC) followed by exposure of NIR light for activating selective cytotoxicity on targeted cancer cells and may have application to TNBC. In order to minimize the dose of APC while maximizing the therapeutic effects, dosing of the APC and NIR light need to be optimized. In this study, we investigate in vitro and in vivo efficacy of cetuximab (cet)-IR700 NIR-PIT on two breast cancer models MDAMB231 (TNBC, EGFR moderate) and MDAMB468 (TNBC, EGFR high) cell lines, and demonstrate a method to optimize the dosing APC and NIR light. Method After validating in vitro cell-specific cytotoxicity, NIR-PIT therapeutic effects were investigated in mouse models using cell lines derived from TNBC tumors. Tumor-bearing mice were separated into 4 groups for the following treatments: (1) no treatment (control); (2) 300 μg of cet-IR700 i.v., (APC i.v. only); (3) NIR light exposure only, NIR light was administered at 50 J/cm2 on day 1 and 100 J/cm2 on day 2 (NIR light only); (4) 300 μg of cet-IR700 i.v., NIR light was administered at 50 J/cm2 on day 1 after injection and 100 J/cm2 of light on day 2 after injection (one shot NIR-PIT). To compare different treatment regimens with a fixed dose of APC, we added the following treatments (5) 100 μg of cet-IR700 i.v., NIR light administered at 50 J/cm2 on day 1 and 50 μg of cet-IR700 i.v. immediately after NIR-PIT, then NIR light was administered at 100 J/cm2 on day 2, which were performed two times every week (“two split” NIR-PIT) and (6) 100 μg of cet-IR700 i.v., NIR light was administered at 50 J/cm2 on day 1 and 100 J/cm2 on day 2, which were performed three times per week (“three split” NIR-PIT). Result Both specific binding and NIR-PIT effects were greater with MDAMB468 than MDAMB231 cells in vitro. Tumor accumulation of cet-IR700 in MDAMB468 tumors was significantly higher (p < 0.05) than in MDAMB231 tumors in vivo. Tumor growth and survival of MDAMB231 tumor bearing mice was significantly lower in the NIR-PIT treatment group (p < 0.05). In MDAMB468 bearing mice, tumor growth and survival was significantly improved in the NIR-PIT treatment groups in all treatment regimens (one shot NIR-PIT; p < 0.05, “two split” NIR-PIT; p < 0.01, “three split” NIR-PIT; p < 0.001) compared with control groups. Conclusion NIR-PIT for TNBC was effective regardless of expression of EGFR, however, greater cell killing was shown with higher EGFR expression tumor in vitro. In all treatment regimens, NIR-PIT suppressed tumor growth, resulting in significantly prolonged survival that further improved by splitting the APC dose and using repeated light exposures. PMID:26313651
Nagaya, Tadanobu; Sato, Kazuhide; Harada, Toshiko; Nakamura, Yuko; Choyke, Peter L; Kobayashi, Hisataka
2015-01-01
Triple-negative breast cancer (TNBC) is considered one of the most aggressive subtypes of breast cancer. Near infrared photoimmunotherapy (NIR-PIT) is a cancer treatment that employs an antibody-photosensitizer conjugate (APC) followed by exposure of NIR light for activating selective cytotoxicity on targeted cancer cells and may have application to TNBC. In order to minimize the dose of APC while maximizing the therapeutic effects, dosing of the APC and NIR light need to be optimized. In this study, we investigate in vitro and in vivo efficacy of cetuximab (cet)-IR700 NIR-PIT on two breast cancer models MDAMB231 (TNBC, EGFR moderate) and MDAMB468 (TNBC, EGFR high) cell lines, and demonstrate a method to optimize the dosing APC and NIR light. After validating in vitro cell-specific cytotoxicity, NIR-PIT therapeutic effects were investigated in mouse models using cell lines derived from TNBC tumors. Tumor-bearing mice were separated into 4 groups for the following treatments: (1) no treatment (control); (2) 300 μg of cet-IR700 i.v., (APC i.v. only); (3) NIR light exposure only, NIR light was administered at 50 J/cm2 on day 1 and 100 J/cm2 on day 2 (NIR light only); (4) 300 μg of cet-IR700 i.v., NIR light was administered at 50 J/cm2 on day 1 after injection and 100 J/cm2 of light on day 2 after injection (one shot NIR-PIT). To compare different treatment regimens with a fixed dose of APC, we added the following treatments (5) 100 μg of cet-IR700 i.v., NIR light administered at 50 J/cm2 on day 1 and 50 μg of cet-IR700 i.v. immediately after NIR-PIT, then NIR light was administered at 100 J/cm2 on day 2, which were performed two times every week ("two split" NIR-PIT) and (6) 100 μg of cet-IR700 i.v., NIR light was administered at 50 J/cm2 on day 1 and 100 J/cm2 on day 2, which were performed three times per week ("three split" NIR-PIT). Both specific binding and NIR-PIT effects were greater with MDAMB468 than MDAMB231 cells in vitro. Tumor accumulation of cet-IR700 in MDAMB468 tumors was significantly higher (p < 0.05) than in MDAMB231 tumors in vivo. Tumor growth and survival of MDAMB231 tumor bearing mice was significantly lower in the NIR-PIT treatment group (p < 0.05). In MDAMB468 bearing mice, tumor growth and survival was significantly improved in the NIR-PIT treatment groups in all treatment regimens (one shot NIR-PIT; p < 0.05, "two split" NIR-PIT; p < 0.01, "three split" NIR-PIT; p < 0.001) compared with control groups. NIR-PIT for TNBC was effective regardless of expression of EGFR, however, greater cell killing was shown with higher EGFR expression tumor in vitro. In all treatment regimens, NIR-PIT suppressed tumor growth, resulting in significantly prolonged survival that further improved by splitting the APC dose and using repeated light exposures.
NASA Technical Reports Server (NTRS)
Bauman, William H., III; Crawford, Winifred C.
2012-01-01
As with the previous year, the past year of this award has been productive and a number of important results and refereed publications either submitted or published. Some of our research results are discussed here and a list the papers submitted or published in the past year is provided. Besides our original model of an outer heliosheath source for the IBEX "ribbon" we have continued to explore alternative possibilities and further our understanding of this very complex region, especially in light of the possibility raised by the IBEX results that suggest the possibility of a 1-shock model.
SDSS IV MaNGA: Dependence of Global and Spatially Resolved SFR–M ∗ Relations on Galaxy Properties
NASA Astrophysics Data System (ADS)
Pan, Hsi-An; Lin, Lihwai; Hsieh, Bau-Ching; Sánchez, Sebastián F.; Ibarra-Medel, Héctor; Boquien, Médéric; Lacerna, Ivan; Argudo-Fernández, Maria; Bizyaev, Dmitry; Cano-Díaz, Mariana; Drory, Niv; Gao, Yang; Masters, Karen; Pan, Kaike; Tabor, Martha; Tissera, Patricia; Xiao, Ting
2018-02-01
The galaxy integrated Hα star formation rate–stellar mass relation, or SFR(global)–M *(global) relation, is crucial for understanding star formation history and evolution of galaxies. However, many studies have dealt with SFR using unresolved measurements, which makes it difficult to separate out the contamination from other ionizing sources, such as active galactic nuclei and evolved stars. Using the integral field spectroscopic observations from SDSS-IV MaNGA, we spatially disentangle the contribution from different Hα powering sources for ∼1000 galaxies. We find that, when including regions dominated by all ionizing sources in galaxies, the spatially resolved relation between Hα surface density (ΣHα (all)) and stellar mass surface density (Σ*(all)) progressively turns over at the high Σ*(all) end for increasing M *(global) and/or bulge dominance (bulge-to-total light ratio, B/T). This in turn leads to the flattening of the integrated Hα(global)–M *(global) relation in the literature. By contrast, there is no noticeable flattening in both integrated Hα(H II)–M *(H II) and spatially resolved ΣHα (H II)–Σ*(H II) relations when only regions where star formation dominates the ionization are considered. In other words, the flattening can be attributed to the increasing regions powered by non-star-formation sources, which generally have lower ionizing ability than star formation. An analysis of the fractional contribution of non-star-formation sources to total Hα luminosity of a galaxy suggests a decreasing role of star formation as an ionizing source toward high-mass, high-B/T galaxies and bulge regions. This result indicates that the appearance of the galaxy integrated SFR–M * relation critically depends on their global properties (M *(global) and B/T) and relative abundances of various ionizing sources within the galaxies.
Wei, Zi; Cady, Clyde W; Brudvig, Gary W; Hou, Harvey J M
2011-01-01
The Mn cluster in photosystem II (PS II) is believed to play an important role in the UV photoinhibition of green plants, but the mechanism is still not clear at a molecular level. In this work, the photochemical stability of [Mn(III)(O)(2)Mn(IV)(H(2)O)(2)(Terpy)(2)](NO(3))(3) (Terpy=2,2':6',2''-terpyridine), designated as Mn-oxo mixed-valence dimer, a well characterized functional model of the oxygen-evolving complex in PS II, was examined in aqueous solution by exposing the complex to excess light irradiation at six different wavelengths in the range of 250 to 700 nm. The photodamage of the Mn-oxo mixed-valence dimer was confirmed by the decrease of its oxygen-evolution activity measured in the presence of the chemical oxidant oxone. Ultraviolet light irradiation induced a new absorption peak at around 400-440 nm of the Mn-oxo mixed-valence dimer. Visible light did not have the same effect on the Mn-oxo mixed-valence dimer. We speculate that the spectral change may be caused by conversion of the Mn(III)O(2)Mn(IV) dimer into a new structure--Mn(IV)O(2)Mn(IV). In the processes, the appearance of a 514 nm fluorescence peak was observed in the solution and may be linked to the hydration or protonation of Terpy ligand in the Mn-oxo dimer. In comparing the response of the PS II functional model compound and the PS II complex to excess light radiation, our results support the idea that UV photoinhibition is triggered at the Mn(4)Ca center of the oxygen-evolution complex in PS II by forming a modified structure, possibly a Mn(IV) species, and that the reaction of Mn ions is likely the initial step. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Wilson, Harold A.
2014-05-01
Preface; Introduction; Part I. Mechanics and Properties of Matter: 1. Space and time; 2. Motion; 3. The laws of motion and matter; 4. Force and motion; 5. Work and study; 6. Mechanics of rigid bodies; 7. Gravitation; 8. Elasticity; 9. The properties of liquids; Part II. Heat: 1. Temperature; 2. The expansion of solid bones with rise of temperature; 3. The expansion of liquids with rise of temperature; 4. The properties of gases; 5. Quantity of heat. Specific heat; 6. Change of state. Solid-liquid; 7. Change of state. Liquid-vapour; 8. Convection and conduction; 9. Heat a form of energy; 10. The conversion of heat into work; 11. The kinetic theory of gases; Part III. Sound: 1. Production and velocity of sound; 2. Wave motion; 3. Wave trains; 4. Musical notes; 5. Reflection, refraction, interference of sound and composition of perpendicular vibrations; 6. Resonance; 7. Vibration of strings; 8. Vibration of air in open and closed spaces; Part IV. Light: 1. Sources of light. Photometry; 2. Reflection and refraction at plane surfaces; 3. Spherical mirrors; 4. Lenses; 5. Dispersion; 6. Colour; 7. Optical instruments; 8. The velocity of light; 9. Interference and diffraction; 10. Polarization and double refraction; 11. Energy of light. Invisible radiations; Index.
NASA Astrophysics Data System (ADS)
Sun, Mouyuan; Xue, Yongquan; Richards, Gordon T.; Trump, Jonathan R.; Shen, Yue; Brandt, W. N.; Schneider, D. P.
2018-02-01
We use the multi-epoch spectra of 362 quasars from the Sloan Digital Sky Survey Reverberation Mapping project to investigate the dependence of the blueshift of C IV relative to Mg II on quasar properties. We confirm that high-blueshift sources tend to have low C IV equivalent widths (EWs), and that the low-EW sources span a range of blueshift. Other high-ionization lines, such as He II, also show similar blueshift properties. The ratio of the line width (measured as both the full width at half maximum and the velocity dispersion) of C IV to that of Mg II increases with blueshift. Quasar variability enhances the connection between the C IV blueshift and quasar properties (e.g., EW). The variability of the Mg II line center (i.e., the wavelength that bisects the cumulative line flux) increases with blueshift. In contrast, the C IV line center shows weaker variability at the extreme blueshifts. Quasars with the high-blueshift C IV lines tend to have less variable continuum emission, when controlling for EW, luminosity, and redshift. Our results support the scenario that high-blueshift sources tend to have large Eddington ratios.
Code of Federal Regulations, 2012 CFR
2012-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2011 CFR
2011-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2013 CFR
2013-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... light liquid service. The leak identification on a valve in gas/vapor or light liquid service may be... that monitoring. The leak identification on a connector in gas/vapor or light liquid service may be... or light liquid service that is subject to the provisions of § 63.1027(b)(3)(iv), may be removed...
Integrating plug-in electric vehicles into the electric power system
NASA Astrophysics Data System (ADS)
Wu, Di
This dissertation contributes to our understanding of how plug-in hybrid electric vehicles (PHEVs) and plug-in battery-only electric vehicles (EVs)---collectively termed plug-in electric vehicles (PEVs)---could be successfully integrated with the electric power system. The research addresses issues at a diverse range of levels pertaining to light-duty vehicles, which account for the majority of highway vehicle miles traveled, energy consumed by highway travel modes, and carbon dioxide emissions from on-road sources. Specifically, the following topics are investigated: (i) On-board power electronics topologies for bidirectional vehicle-to-grid and grid-to-vehicle power transfer; (ii) The estimation of the electric energy and power consumption by fleets of light-duty PEVs; (iii) An operating framework for the scheduling and dispatch of electric power by PEV aggregators; (iv) The pricing of electricity by PHEV aggregators and how it affects the decision-making process of a cost-conscious PHEV owner; (v) The impacts on distribution systems from PEVs under aggregator control; (vi) The modeling of light-duty PEVs for long-term energy and transportation planning at a national scale.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallagher, J. D.; Xu, C.; Menéndez, J.
This paper reports initial the demonstration of prototype Ge{sub 1−x−y}Si{sub x}Sn{sub y} light emitting diodes with distinct direct and indirect edges and high quality I-V characteristics. The devices are fabricated on Si (100) wafers in heterostructure pin geometry [n-Ge/i-Ge{sub 1−x−y}Si{sub x}Sn{sub y}/p-Ge(Sn/Si)] using ultra low-temperature (T < 300 °C) depositions of the highly reactive chemical sources Si{sub 4}H{sub 10}, Ge{sub 4}H{sub 10}, Ge{sub 3}H{sub 8}, and SnD{sub 4}. The Sn content in the i-Ge{sub 1−x−y}Si{sub x}Sn{sub y} layer was varied from ∼3.5% to 11%, while the Si content was kept constant near 3%. The Si/Sn amounts in the p-layer were selected to mitigatemore » the lattice mismatch so that the top interface grows defect-free, thereby reducing the deleterious effects of mismatch-induced dislocations on the optical/electrical properties. The spectral responsivity plots of the devices reveal sharp and well-defined absorption edges that systematically red-shift in the mid-IR from 1750 to 2100 nm with increasing Sn content from 3.5% to 11%. The electroluminescence spectra reveal strong direct-gap emission peaks and weak lower energy shoulders attributed to indirect gaps. Both peaks in a given spectrum red-shift with increasing Sn content and their separation decreases as the material approaches direct gap conditions in analogy with binary Ge{sub 1−y}Sn{sub y} counterparts. These findings-combined with the enhanced thermal stability of Ge{sub 1−x−y}Si{sub x}Sn{sub y} relative to Ge{sub 1−y}Sn{sub y} and the observation that ternary alloy disorder does not adversely affect the emission properties—indicate that Ge{sub 1−x−y}Si{sub x}Sn{sub y} may represent a practical target system for future generations of group-IV light sources on Si.« less
First Detection of the Hatchett-McCray Effect in the High-Mass X-ray Binary
NASA Technical Reports Server (NTRS)
Sonneborn, G.; Iping, R. C.; Kaper, L.; Hammerschiag-Hensberge, G.; Hutchings, J. B.
2004-01-01
The orbital modulation of stellar wind UV resonance line profiles as a result of ionization of the wind by the X-ray source has been observed in the high-mass X-ray binary 4U1700-37/HD 153919 for the first time. Far-UV observations (905-1180 Angstrom, resolution 0.05 Angstroms) were made at the four quadrature points of the binary orbit with the Far Ultraviolet Spectroscopic Explorer (FUSE) in 2003 April and August. The O6.5 laf primary eclipses the X-ray source (neutron star or black hole) with a 3.41-day period. Orbital modulation of the UV resonance lines, resulting from X-ray photoionization of the dense stellar wind, the so-called Hatchett-McCray (HM) effect, was predicted for 4U1700-37/HD153919 (Hatchett 8 McCray 1977, ApJ, 211, 522) but was not seen in N V 1240, Si IV 1400, or C IV 1550 in IUE and HST spectra. The FUSE spectra show that the P V 1118-1128 and S IV 1063-1073 P-Cygni lines appear to vary as expected for the HM effect, weakest at phase 0.5 (X-ray source conjunction) and strongest at phase 0.0 (X-ray source eclipse). The phase modulation of the O VI 1032-1037 lines, however, is opposite to P V and S IV, implying that O VI may be a byproduct of the wind's ionization by the X-ray source. Such variations were not observed in N V, Si IV, and C IV because of their high optical depth. Due to their lower cosmic abundance, the P V and S IV wind lines are unsaturated, making them excellent tracers of the ionization conditions in the O star's wind.
The Evolution of Quasar C IV and Si IV Broad Absorption Lines over Multi-year Timescales
NASA Astrophysics Data System (ADS)
Gibson, Robert R.; Brandt, W. N.; Gallagher, S. C.; Hewett, Paul C.; Schneider, Donald P.
2010-04-01
We investigate the variability of C IV λ1549 broad absorption line (BAL) troughs over rest-frame timescales of up to ≈7 yr in 14 quasars at redshifts z >~ 2.1. For nine sources at sufficiently high redshift, we also compare the C IV and Si IV λ1400 absorption variation. We compare shorter and longer term variability using spectra from up to four different epochs per source and find complex patterns of variation in the sample overall. The scatter in the change of absorption equivalent width (EW), ΔEW, increases with the time between observations. BALs do not, in general, strengthen or weaken monotonically, and variation observed over shorter (lsimmonths) timescales is not predictive of multi-year variation. We find no evidence for asymmetry in the distribution of ΔEW that would indicate that BALs form and decay on different timescales, and we constrain the typical BAL lifetime to be gsim30 yr. The BAL absorption for one source, LBQS 0022+0150, has weakened and may now be classified as a mini-BAL. Another source, 1235+1453, shows evidence of variable, blue continuum emission that is relatively unabsorbed by the BAL outflow. C IV and Si IV BAL shape changes are related in at least some sources. Given their high velocities, BAL outflows apparently traverse large spatial regions and may interact with parsec-scale structures such as an obscuring torus. Assuming BAL outflows are launched from a rotating accretion disk, notable azimuthal symmetry is required in the outflow to explain the relatively small changes observed in velocity structure over times up to 7 yr.
Dai, Yunlu; Xiao, Haihua; Liu, Jianhua; Yuan, Qinghai; Ma, Ping'an; Yang, Dongmei; Li, Chunxia; Cheng, Ziyong; Hou, Zhiyao; Yang, Piaoping; Lin, Jun
2013-12-18
Controlling anticancer drug activity and release on demand is very significant in cancer therapy. The photoactivated platinum(IV) pro-drug is stable in the dark and can be activated by UV light. In this study, we develop a multifunctional drug delivery system combining upconversion luminescence/magnetic resonance/computer tomography trimodality imaging and NIR-activated platinum pro-drug delivery. We use the core-shell structured upconversion nanoparticles to convert the absorbed NIR light into UV to activate the trans-platinum(IV) pro-drug, trans,trans,trans-[Pt(N3)2(NH3)(py)(O2CCH2CH2COOH)2]. Compared with using the UV directly, the NIR has a higher tissue penetration depth and is less harmful to health. Meanwhile, the upconversion nanoparticles can effectively deliver the platinum(IV) pro-drugs into the cells by endocytosis. The mice treated with pro-drug-conjugated nanoparticles under near-infrared (NIR) irradiation demonstrated better inhibition of tumor growth than that under direct UV irradiation. This multifunctional nanocomposite could be used as multimodality bioimaging contrast agents and transducers by converting NIR light into UV for control of drug activity in practical cancer therapy.
Kumata, Hidetoshi; Mori, Mika; Takahashi, Sho; Takamiya, Shohei; Tsuzuki, Mikio; Uchida, Tatsuya; Fujiwara, Kitao
2011-12-01
To propose new molecular markers for tire-wear emissions, four dihydroresin acids, that is, 8-isopimaren-18-oic acid (I), 8-pimaren-18-oic acid (II), 13β(H)-abieten-18-oic acid (III), and 13α(H)-abiet-8-en-18-oic acid (IV), were identified and investigated for source specificities, distributions, and environmental stabilities. The absence of I-IV in natural sources and the linear correlations between dihydroresin acids with different skeletons in tires and in environmental samples demonstrated that I-IV are specific markers for synthetic rubbers. The ratio of III + IV to the sum of III + IV plus abietic acid showed the resin acids distribution between different environmental compartments receiving contributions from traffic and natural sources. The physicochemical properties and results of photolysis experiments suggested that I-IV can set lower limits for tire-wear contributions to environmental loads of particulate matter (PM) and polycyclic aromatic hydrocarbons with molecular weight ≥202. By comparing III + IV concentrations or (III+IV)/pyrene or (III+IV)/benzo[a]pyrene ratios in tires and those in environmental matrices, the contributions of tire-wear emissions to PM, pyrene, and benzo[a]pyrene were estimated to be 0.68 ± 0.54%, 6.9 ± 4.8%, and 0.37 ± 0.18% in roadside PM and 0.83 ± 0.21%, 0.88 ± 0.52%, and 0.08 ± 0.06% in rooftop PM.
Rico-Oller, Beatriz; Boudjemaa, Amel; Bahruji, Hasliza; Kebir, Mohammed; Prashar, Sanjiv; Bachari, Khaldoun; Fajardo, Mariano; Gómez-Ruiz, Santiago
2016-09-01
Novel nanomaterials based on doped TiO2 nanoparticles with different morphological, textural and band-gap properties have been synthesized using scalable methods. The influence of synthetic parameters such as titanium source (titanium(IV) isopropoxide and titanium(IV) butoxide), doping quantity (0%, 2% or 5% Zn), acidic solution for the hydrolysis reaction (ascorbic acid, nitric acid) and calcination temperatures (500°C and 600°C) was simultaneously investigated. The obtained nanomaterials were characterized by different methods and photocatalytic tests of methylene blue (MB) degradation under UV-light were conducted to determine their activity. The results revealed that the synthesized nanomaterials are porous aggregates with very high crystallinity and are mainly composed of the anatase phase; although their physical properties vary depending on the different synthetic parameters employed. These changes are able to modify the apparent rate constant of the degradation of MB up to one order of magnitude, indicating, substantial changes in their photoactivity. Hybrid materials TiO2-Pd nanoparticles have also been prepared, characterized and tested for hydrogen production using photocatalytic methanol reforming where supported palladium nanoparticles acted as co-catalyst. Furthermore, the hybrid materials TiO2-Pd nanoparticles were studied in photocatalytic tests of methylene blue degradation under visible LED-light. The results obtained in the production of hydrogen from the photocatalytic reforming of methanol by hybrid materials suggest that the reported hybrid systems could be suitable photocatalysts for future sustainable hydrogen production upon tuning of the morphological, textural and band gap energy properties to allow processes to be carried out under visible light. Copyright © 2015 Elsevier B.V. All rights reserved.
Future Synchrotron Light Sources Based on Ultimate Storage Rings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Yunhai; /SLAC
2012-04-09
The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving anmore » ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend achromatic cell, we have made significant progress with the design of PEP-X, a USR that would inhabit the decommissioned PEP-II tunnel at SLAC. The enlargement of the dynamic aperture is largely a result of the cancellations of the 4th-order resonances in the 3rd-order achromats and the effective use of lattice optimization programs. In this paper, we will show those cancellations of the 4th-order resonances using an analytical approach based on the exponential Lie operators and the Poisson brackets. Wherever possible, our analytical results will be compared with their numerical counterparts. Using the derived formulae, we will construct 4th-order geometric achromats and use them as modules for the lattice of the PEP-X USR, noting that only geometric terms are canceled to the 4th order.« less
NASA Astrophysics Data System (ADS)
Guan, Yingli; Song, Lixin; Zhou, Yangyang; Yin, Xin; Xie, Xueyao; Xiong, Jie
2017-03-01
Two kinds of TiO2 microspheres (TMS) with average diameter of 1500 nm but different surface were fabricated by solvothermal method from different Ti source. The effect of TMS on the light harvesting and photovoltaic performance of dye-sensitized solar cells (DSSCs)was investigated. The UV-Vis diffusion reflectance spectra and absorption spectra of N719 dye in detached solutions proved that the TMS showed dual functions of light scattering and dye-adsorption which was an important functional material in DSSCs. The results showed that the TMS made from titanium(IV) isopropoxide with rough surface (TMSR) exhibited better photovoltaic performance than that of TMS made from tetrabutyl titanate with smooth surface (TMSS). To further improve the photovoltaic performance, the double-layered DSSCs made of P25 as an underlayer and TMS as a light-scattering layer (P25-TMS) were fabricated. The photovoltaic performance of double-layered DSSCs was higher than that of the single-layered DSSCs with similar thickness. Especially, the DSSCs made of P25 as an underlayer and the TMSR as a light-scattering layer (P25-TMSR) had a highest power conversion efficiency of 7.62%. This was higher than that of single-layered TMSR-based cell (5.54%), P25-based cell (5.75%), and double-layered P25-TMSS-based cell (6.78%) with similar thickness. This was mainly attributed to the large specific surface area, superior light scattering ability, and fast electron transport of TMSR.
NASA Astrophysics Data System (ADS)
Ma, Zhinan; Zhuang, Jibin; Zhang, Xu; Zhou, Zhen
2018-06-01
Because of graphene and phosphorene, two-dimensional (2D) layered materials of group IV and group V elements arouse great interest. However, group IV-V monolayers have not received due attention. In this work, three types of SiP monolayers were computationally designed to explore their electronic structure and optical properties. Computations confirm the stability of these monolayers, which are all indirect-bandgap semiconductors with bandgaps in the range 1.38-2.21 eV. The bandgaps straddle the redox potentials of water at pH = 0, indicating the potential of the monolayers for use as watersplitting photocatalysts. The computed optical properties demonstrate that certain monolayers of SiP 2D materials are absorbers of visible light and would serve as good candidates for optoelectronic devices.
DOE/NNSA perspective safeguard by design: GEN III/III+ light water reactors and beyond
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pan, Paul Y
2010-12-10
An overview of key issues relevant to safeguards by design (SBD) for GEN III/IV nuclear reactors is provided. Lessons learned from construction of typical GEN III+ water reactors with respect to SBD are highlighted. Details of SBD for safeguards guidance development for GEN III/III+ light water reactors are developed and reported. This paper also identifies technical challenges to extend SBD including proliferation resistance methodologies to other GEN III/III+ reactors (except HWRs) and GEN IV reactors because of their immaturity in designs.
Contrast in the Photoelectric Effect of Organic and Biochemical Surfaces
Birrell, G. B.; Burke, C.; Dehlinger, P.; Griffith, O. H.
1973-01-01
The photoelectric effect can provide the physical basis for a new method of mapping organic and biological surfaces. The technique, photoelectron microscopy, is similar to fluorescence microscopy using incident ultraviolet light except that photoejected electrons form the image of the specimen surface. In this work the minimum wavelengths of incident light required to produce an image were determined for the molecules 3,6-bis(dimethylamino)acridine (acridine orange) (I), benzo[a]pyrene (II), N,N,N′,N′-tetraphenylbenzidine (III), and copper phthalocyanine (IV). The photoelectron image thresholds for these compounds are 220 (I), 215 (II), 220 (III), and 240 nm (IV), all ±5 nm. Contrast of I-IV with respect to typical protein, lipid, nucleic acid, and polysaccharide surfaces was examined over the wavelength range 240-180 nm. The low magnification micrographs exhibited bright areas corresponding to I-IV but dark regions for the biochemical surfaces. The high contrast suggests the feasibility of performing extrinsic photoelectron microscopy experiments through selective labeling of sites on biological surfaces. ImagesFIGURE 3 PMID:4704486
NASA Astrophysics Data System (ADS)
Horne, Keith D.; Agn Storm Team
2015-01-01
Two-dimensional velocity-delay maps of AGN broad emission line regions can be recovered by modelling observations of reverberating emission-line profiles on the assumption that the line profile variations are driven by changes in ionising radiation from a compact source near the black hole. The observable light travel time delay resolves spatial structure on iso-delay paraboloids, while the doppler shift resolves kinematic structure along the observer's line-of-sight. Velocity-delay maps will be presented and briefly discussed for the Lyman alpha, CIV and Hbeta line profiles based on the HST and ground-based spectrophotometric monitoring of NGC 5548 during the 2014 AGN STORM campaign.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eriksson, Mikael
Not very long ago, the 3{sup rd} generation storage ring technology was judged as mature. Most of the 3{sup rd} generation storage rings used the Double-Bend Achromat (DBA) or Triple-Bend Achromat (TBA) concepts. It was however a well-known fact that increasing the number of magnet cells in the rings is a powerful way of decreasing the electron beam emittance and thus the source brilliance, but at the penalty of increasing the size and cost of the rings. Preserving the Dynamic Aperture (DA) in the rings became also an issue when increasing the number of magnet cells. The Multi-Bend Achromat (MBA)more » concept, including a miniaturization of the ring elements, has now drastically changed the picture. The MBA rings, now in construction or being planned, offer orders of magnitudes higher brilliance than rings of conventional designs. Several light sources around the world are now implementing or planning to implement this MBA concept. This article touches on the science drivers for higher brilliance. We will then describe the MBA concept with its advantages as well as its challenges. A short survey of the MBA activity around the world will also be presented. The author apologies for focusing on the MAX IV project regarding technical solutions. This is motivated by that MAX IV is the facility he knows best and it might be regarded as a fore-runner for the MBA concept.« less
Yamada, Toshishige; Yamada, Hidenori; Lohn, Andrew J; Kobayashi, Nobuhiko P
2011-02-04
Detailed electron transport analysis is performed for an ensemble of conical indium phosphide nanowires bridging two hydrogenated n(+)-silicon electrodes. The current-voltage (I-V) characteristics exhibit a Coulomb staircase in the dark with a period of ∼ 1 V at room temperature. The staircase is found to disappear under light illumination. This observation can be explained by assuming the presence of a tiny Coulomb island, and its existence is possible due to the large surface depletion region created within contributing nanowires. Electrons tunnel in and out of the Coulomb island, resulting in the Coulomb staircase I-V. Applying light illumination raises the electron quasi-Fermi level and the tunneling barriers are buried, causing the Coulomb staircase to disappear.
Baines, S.B.; Fisher, N.S.; Doblin, M.A.; Cutter, G.A.; Cutter, L.S.; Cole, B.
2004-01-01
The potentially toxic element selenium is first concentrated from solution to a large but highly variable degree by algae and bacteria before being passed on to consumers. The large loads of abiotic and detrital suspended particles often present in rivers and estuaries may obscure spatial and temporal patterns in Se concentrations at the base of the food web. We used radiotracers to estimate uptake of both selenite (Se(IV)) and C by intact plankton communities at two sites in the Sacramento/San Joaquin River Delta. Our goals were to determine (1) whether C and Se(IV) uptake were coupled, (2) the role of bacteria in Se(IV) uptake, and (3) the Se:C uptake ratio of newly produced organic material. Se(IV) uptake, like C uptake, was strongly related to irradiance. The shapes of both relationships were very similar except that at least 42-56% of Se(IV) uptake occurred in the dark, whereas C uptake in the dark was negligible. Of this dark Se(IV) uptake, 34-67% occurred in the 0.2-1.0-??m size fraction, indicating significant uptake by bacteria. In addition to dark uptake, total Se(IV) uptake consisted of a light-driven component that was in fixed proportion to C uptake. Our estimates of daily areal Se(IV):C uptake ratios agreed very well with particulate Se:C measured at a site dominated by phytoplankton biomass. Estimates of bacterial Se:C were 2.4-13 times higher than for the phytoplankton, suggesting that bacteriovores may be exposed to higher dietary Se concentrations than herbivores.
Performance Characterization of Dye-Sensitized Photovoltaics under Indoor Lighting.
Chen, Chia-Yuan; Jian, Zih-Hong; Huang, Shih-Han; Lee, Kun-Mu; Kao, Ming-Hsuan; Shen, Chang-Hong; Shieh, Jia-Min; Wang, Chin-Li; Chang, Chiung-Wen; Lin, Bo-Zhi; Lin, Ching-Yao; Chang, Ting-Kuang; Chi, Yun; Chi, Cheng-Yu; Wang, Wei-Ting; Tai, Yian; Lu, Ming-De; Tung, Yung-Liang; Chou, Po-Ting; Wu, Wen-Ti; Chow, Tahsin J; Chen, Peter; Luo, Xiang-Hao; Lee, Yuh-Lang; Wu, Chih-Chung; Chen, Chih-Ming; Yeh, Chen-Yu; Fan, Miao-Syuan; Peng, Jia-De; Ho, Kuo-Chuan; Liu, Yu-Nan; Lee, Hsiao-Yi; Chen, Chien-Yu; Lin, Hao-Wu; Yen, Chia-Te; Huang, Yu-Ching; Tsao, Cheng-Si; Ting, Yu-Chien; Wei, Tzu-Chien; Wu, Chun-Guey
2017-04-20
Indoor utilization of emerging photovoltaics is promising; however, efficiency characterization under room lighting is challenging. We report the first round-robin interlaboratory study of performance measurement for dye-sensitized photovoltaics (cells and mini-modules) and one silicon solar cell under a fluorescent dim light. Among 15 research groups, the relative deviation in power conversion efficiency (PCE) of the samples reaches an unprecedented 152%. On the basis of the comprehensive results, the gap between photometry and radiometry measurements and the response of devices to the dim illumination are identified as critical obstacles to the correct PCE. Therefore, we use an illuminometer as a prime standard with a spectroradiometer to quantify the intensity of indoor lighting and adopt the reverse-biased current-voltage (I-V) characteristics as an indicator to qualify the I-V sampling time for dye-sensitized photovoltaics. The recommendations can brighten the prospects of emerging photovoltaics for indoor applications.
Revised and extended analysis of Br IV
NASA Astrophysics Data System (ADS)
Riyaz, A.; Rahimullah, K.; Tauheed, A.
2014-01-01
The spectrum of three-times ionized bromine Br IV has been studied in the 319-2350 Å wavelength region. The spectrum was recorded on a 3-m normal incidence vacuum spectrograph at the St. Francis Xavier University, Antigonish (Canada) and 6.65-m grazing incidence spectrograph at the Zeeman laboratory (Amsterdam). The light sources used were a triggered spark and sliding spark, respectively. The ground configuration of Br IV 3d104s24p2, the excited configurations 3d104s4p3+3d104s24p (4d+5d+6d+5s+6s+7s) in the odd parity system and 3d104s24p (5p+4f+5f)+3d104s4p2 (4d+5s)+3d104p4 in the even parity system have been studied. Relativistic Hartree-Fock (HFR) and least squares fitted (LSF) parametric calculations were used to interpret the observed spectrum. 120 Levels of Br IV have now been established, 58 being new. Among 424 spectral lines, 277 are newly classified. The levels 4s4p35S2, 4s24p4d 3F4 and 4p5p (3P0, 1, 3D1, 2, 3S1) are revised. We estimate the accuracy of our measured wavelength for sharp and unblended lines to be ±0.005 Å. The ionization limit is determined as 385,390±100 cm-1 (47.782±0.012 eV).
OGLE-IV Transient Search report 07 August 2015
NASA Astrophysics Data System (ADS)
Wyrzykowski, L.; Kostrzewa-Rutkowska, Z.; Udalski, A.; Kozlowski, S.; Poleski, R.; Pietrzynski, G.; Sitek, M.
2015-08-01
The OGLE-IV Transient Detection System (Wyrzykowski et al. 2014, AcA,64,197; Kozlowski et al. 2013) reports the discovery of 10 new transients. Most of them appeared near or on top of apparent galaxies and their light curves resemble those of supernovae near or after their peak brightness.
The two variables in the triple system HR 6469 = V819 Her: One eclipsing, one spotted
NASA Technical Reports Server (NTRS)
Van Hamme, Walter V.; Hall, Douglas S.; Hargrove, Adam W.; Henry, Gregory W.; Wasson, Rick; Barksdale, William S.; Chang, Sandy; Fried, Robert E.; Green, Charles L.; Lines, Helen C.
1994-01-01
A complete BV light curve, from 14 nights of good data obtained with the Vanderbilt University-Tennessee State University (VU-TSU) automatic telescope, are presented and solved with the Wilson-Devinney program. Third light is evaluated, with the companion star brighter by 0.58(sup m) in V and 0.11(sup m) in B. The eclipses are partial. Inferred color indices yield F2 V and F8 V for the eclipsing pair and G8 IV-III for the distant companion star. After removing the variability due to eclipses, we study the residual variability of the G8 IV-III star over the ten years 1982 to 1992. Each yearly light curve is fit with a two-spot model. Three relatively long-lived spots are identified, with rotation periods of 85.9(sup d), 85.9(sup d), and 86.1(sup d). The weak and intermittent variability is understood because the G8 IV-III star has a Rossby number at the threshold for the onset of heavy spottedness.
Probing the Mysteries of the X-Ray Binary 4U 1210-64 with ASM, MAXI and Suzaku
NASA Astrophysics Data System (ADS)
Coley, Joel B.; Corbet, R.; Mukai, K.; Pottschmidt, K.
2013-01-01
Optical and X-ray observations of 4U 1210-64 (1ES 1210-646) suggest that the source is a High Mass X-ray Binary (HMXB) probably powered by the Be mechanism. Data acquired by the RXTE All Sky Monitor (ASM), the ISS Monitor of All-sky X-ray Image (MAXI) and Suzaku provide a detailed temporal and spectral description of this poorly understood source. Long-term data produced by ASM and MAXI indicate that the source shows two distinct high and low states. A 6.7-day orbital period of the system was found in folded light curves produced by both ASM and MAXI. A two day Suzaku observation in Dec. 2010 took place during a transition from the minimum to the maximum of the folded light curve. The two day Suzaku observation reveals large variations in flux indicative of strong orbit to orbit variability. Flares in the Suzaku light curve can reach nearly 1.4 times the mean count rate. From a spectral analysis of the Suzaku data, emission lines in the Fe K alpha region were detected at 6.4 keV, 6.7 keV and 6.97 keV interpreted as FeI, FeXXV and FeXXVI. In addition, emission lines were observed at approximately 1.0 and 2.6 keV, corresponding to NeX and SXVI respectively. Thermal bremsstrahlung or power law models both modified by interstellar and partially covering absorption provide a good fit to the continuum data. This source is intriguing for these reasons: i) No pulse period was observed; ii) 6.7 day orbital period is much less than typical orbital periods seen in Be/X-ray Binaries; iii) The optical companion is a B5V--an unusual spectral class for an HMXB; iv) There are extended high and low X-ray states.
Design of Weft Detection System in The Stenter Machine
NASA Astrophysics Data System (ADS)
Gu, Minming; Xu, Xianju; Dai, Wenzhan
2017-12-01
In order to build an effective automatic weft-straightening system, it is important for the sensing device to detect most the possible fabric styles, designs, colours and structures, an optical sensing system that detects the angular orientation of weft threads in a moving web of a textile has been built. It contains an adjustable light source, two lens systems and photodiode sensor array. The sensor array includes 13 radial pattern of photosensitive areas that each generate an electrical signal proportional to the total intensity of the light incident on the area. The moving shadow of a weft thread passing over the area will modulate the output signal. A signal processed circuit was built to do the I/V conversion, amplifying, hardware filtering. An embed micro control system then deals with the information of these signals, calculates the angle of the weft drew. Finally, the experiments were done, the results showed that the weft detection system can deal with the fabric weft skew up to 30° and has achieved good results in the application.
NASA Astrophysics Data System (ADS)
Akbas, Y.; Plecenik, T.; Durina, P.; Plecenik, A.; Jukna, A.; Wicks, G.; Sobolewski, Roman
2017-05-01
The asymmetric nano-channel diode (ANCD) is the 2-dimensional electron gas (2DEG) semiconductor nanodevice that, unlike a conventional diode, relies on the device nanostructure and field-controlled transport in a ballistic nanometerwidth channel instead of barriers to develop its asymmetric, diode-like current-voltage (I-V) characteristics. We focus on ANCD optoelectronic properties, and demonstrate that the devices can act as very sensitive, single-photon-level, visiblelight photodetectors. Our test structures consist of 2-μm-long and 230-nm-wide channels and were fabricated using electron-beam lithography on a GaAs/AlGaAs heterostructure with a 2DEG layer, followed by reactive ion etching. The I-V curves were collected by measuring the transport current under the voltage-source biasing condition, both in the dark and under light illumination. The experiments were conducted inside a cryostat, in a temperature range from 300 K to 78 K. As an optical excitation, we used a 800-nm-wavelength, generated by a commercial Ti:sapphire laser operated either at a quasi-continuous-wave mode or as a source of 100-fs-wide pulses. The impact of the light illumination was very clear, and at low temperatures we observed a significant photocurrent Iph 0.25 μA at temperature 78 K for the incident optical power as low as 1 nW, with a limited dark-current background. The magnitude of the device optical responsivity increased linearly with the decrease of the optical power, reaching for 1-nW optical excitation the value as high as 400 A/W at room temperature and >800 A/W at 78K. The physics of the photoresponse gain mechanism in the ANCD arises from a vast disparity between the sub-picosecond transit time of photo-excited electrons travelling in the 2DEG nanochannel and the up to microsecond lifetime of photo-excited holes pushed towards the device substrate.
NASA Astrophysics Data System (ADS)
Cho, Yong-Jung; Kim, Woo-Sic; Lee, Yeol-Hyeong; Park, Jeong Ki; Kim, Geon Tae; Kim, Ohyun
2018-06-01
We investigated the mechanism of formation of the hump that occurs in the current-voltage I-V characteristics of amorphous InGaZnO (a-IGZO) thin film transistors (TFTs) that are exposed to long-term drain bias stress under illumination. Transfer characteristics showed two-stage degradation under the stress. At the beginning of the stress, the I-V characteristics shifted in the negative direction with a degradation of subthreshold slope, but the hump phenomenon developed over time in the I-V characteristics. The development of the hump was related to creation of defects, especially ionized oxygen vacancies which act as shallow donor-like states near the conduction-band minimum in a-IGZO. To further investigate the hump phenomenon we measured a capacitance-voltage C-V curve and performed two-dimensional device simulation. Stretched-out C-V for the gate-to-drain capacitance and simulated electric field distribution which exhibited large electric field near the drain side of TFT indicated that VO2+ were generated near the drain side of TFT, but the hump was not induced when VO2+ only existed near the drain side. Therefore, the degradation behavior under DBITS occurred because VO2+ were created near the drain side, then were migrated to the source side of the TFT.
NASA Astrophysics Data System (ADS)
Tsaplev, Yu. B.
2016-12-01
The kinetics and mechanism of chemiluminescence during the reduction of manganese(IV) ions with lactic acid in an H2SO4-AcOH medium are studied. Kinetic spectrophotometric measurements are used to determine the profiles of change in the concentrations of Mn(IV) and Mn(III) ions during the reaction. The results from kinetic spectrophotometric measurements are compared to the light yield kinetics. The quantum chemiluminescence and chemiexcitation yields reach record values.
NASA Astrophysics Data System (ADS)
Yeti Nuryantini, Ade; Cahya Septia Mahen, Ea; Sawitri, Asti; Wahid Nuryadin, Bebeh
2017-09-01
In this paper, we report on a homemade optical spectrometer using diffraction grating and image processing techniques. This device was designed to produce spectral images that could then be processed by measuring signal strength (pixel intensity) to obtain the light source, transmittance, and absorbance spectra of the liquid sample. The homemade optical spectrometer consisted of: (i) a white LED as a light source, (ii) a cuvette or sample holder, (iii) a slit, (iv) a diffraction grating, and (v) a CMOS camera (webcam). In this study, various concentrations of a carbon nanoparticle (CNP) colloid were used in the particle size sample test. Additionally, a commercial optical spectrometer and tunneling electron microscope (TEM) were used to characterize the optical properties and morphology of the CNPs, respectively. The data obtained using the homemade optical spectrometer, commercial optical spectrometer, and TEM showed similar results and trends. Lastly, the calculation and measurement of CNP size were performed using the effective mass approximation (EMA) and TEM. These data showed that the average nanoparticle sizes were approximately 2.4 nm and 2.5 ± 0.3 nm, respectively. This research provides new insights into the development of a portable, simple, and low-cost optical spectrometer that can be used in nanomaterial characterization for physics undergraduate instruction.
Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva
2017-06-01
The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vasanth, V.; Chen, Yao; Feng, Shiwei
2016-10-10
Hot-channel (HC) structure, observed in the high-temperature passbands of the Atmospheric Imaging Assembly/ Solar Dynamic Observatory , is regarded as one candidate of coronal flux rope that is an essential element of solar eruptions. Here, we present the first radio imaging study of an HC structure in the metric wavelength. The associated radio emission manifests as a moving type-IV (t-IVm) burst. We show that the radio sources co-move outward with the HC, indicating that the t-IV emitting energetic electrons are efficiently trapped within the structure. The t-IV sources at different frequencies present no considerable spatial dispersion during the early stagemore » of the event, while the sources spread gradually along the eruptive HC structure at later stage with significant spatial dispersion. The t-IV bursts are characterized by a relatively high brightness temperature (∼10{sup 7}–10{sup 9} K), a moderate polarization, and a spectral shape that evolves considerably with time. This study demonstrates the possibility of imaging the eruptive HC structure at the metric wavelength and provides strong constraints on the t-IV emission mechanism, which, if understood, can be used to diagnose the essential parameters of the eruptive structure.« less
NASA Astrophysics Data System (ADS)
Gupta, Shashank; Nam, Donguk; Vuckovic, Jelena; Saraswat, Krishna
2018-04-01
A complementary metal-oxide semiconductor compatible on-chip light source is the holy grail of silicon photonics and has the potential to alleviate the key scaling issues arising due to electrical interconnects. Despite several theoretical predictions, a sustainable, room temperature laser from a group-IV material is yet to be demonstrated. In this work, we show that a particular loss mechanism, inter-valence-band absorption (IVBA), has been inadequately modeled until now and capturing its effect accurately as a function of strain is crucial to understanding light emission processes from uniaxially strained germanium (Ge). We present a detailed model of light emission in Ge that accurately models IVBA in the presence of strain and other factors such as polarization, doping, and carrier injection, thereby revising the road map toward a room temperature Ge laser. Strikingly, a special resonance between gain and loss mechanisms at 4%-5% 〈100 〉 uniaxial strain is found resulting in a high net gain of more than 400 cm-1 at room temperature. It is shown that achieving this resonance should be the goal of experimental work rather than pursuing a direct band gap Ge.
40 CFR 86.096-2 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... first. (4) For a diesel heavy-duty engine family: (i) For light heavy-duty diesel engines, period of use of 8 years or 110,000 miles, whichever occurs first. (ii) For medium heavy-duty diesel engines, a... paragraph (4)(iv) of this definition. (iv) For heavy heavy-duty diesel engines used in urban buses, for the...
40 CFR 86.096-2 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... first. (4) For a diesel heavy-duty engine family: (i) For light heavy-duty diesel engines, period of use of 8 years or 110,000 miles, whichever occurs first. (ii) For medium heavy-duty diesel engines, a... paragraph (4)(iv) of this definition. (iv) For heavy heavy-duty diesel engines used in urban buses, for the...
40 CFR 86.096-2 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... first. (4) For a diesel heavy-duty engine family: (i) For light heavy-duty diesel engines, period of use of 8 years or 110,000 miles, whichever occurs first. (ii) For medium heavy-duty diesel engines, a... paragraph (4)(iv) of this definition. (iv) For heavy heavy-duty diesel engines used in urban buses, for the...
Evidence that 50% of BALQSO Outflows Are Situated at Least 100 pc from the Central Source
NASA Astrophysics Data System (ADS)
Arav, Nahum; Liu, Guilin; Xu, Xinfeng; Stidham, James; Benn, Chris; Chamberlain, Carter
2018-04-01
The most robust way for determining the distance of quasar absorption outflows is the use of troughs from ionic excited states. The column density ratio between the excited and resonance states yields the outflow number density. Combined with a knowledge of the outflow’s ionization parameter, a distance from the central source (R) can be determined. Here we report results from two surveys targeting outflows that show troughs from S IV. One survey includes 1091 SDSS and BOSS quasar spectra, and the other includes higher-quality spectra of 13 quasars observed with the Very Large Telescope. Our S IV samples include 38 broad absorption line (BAL) outflows and four mini-BAL outflows. The S IV is formed in the same physical region of the outflow as the canonical outflow-identifying species C IV. Our results show that S IV absorption is only detected in 25% of C IV BAL outflows. The smaller detection fraction is due to the higher total column density (N H) needed to detect S IV absorption. Since R empirically anticorrelates with N H, the results of these surveys can be extrapolated to C IV quasar outflows with lower N H as well. We find that at least 50% of quasar outflows are at distances larger than 100 pc from the central source, and at least 12% are at distances larger than 1000 pc. These results have profound implications for the study of the origin and acceleration mechanism of quasar outflows and their effects on the host galaxy.
Radio- and photosensitization of DNA with compounds containing platinum and bromine atoms
NASA Astrophysics Data System (ADS)
Śmiałek, Małgorzata A.; Ptasińska, Sylwia; Gow, Jason; Vrønning Hoffmann, Søren; Mason, Nigel J.
2015-05-01
Irradiations of plasmid DNA by both X-rays and UV light in the presence and absence of compounds containing platinum and bromine atoms were performed in order to asses the sensitization potential of these compounds. Plasmid DNA pBR322 was incubated with platinum (II) bromide, hydrogen hexabromoplatinate (IV), hydrogen hexahydroxyplatinate (IV) and sodium hexahydroxyplatinate (IV). Incubation was followed by X-ray or UV irradiations. It was found that amongst the sensitizers tested, during irradiations carried out in the presence of platinum (II) bromide, the highest levels of double strand breaks formation upon X-ray treatment were recorded. In contrast much less damage was induced by UV light. Data presented here suggests that this compound may be a promising radiosensitizer for cancer treatment. Contribution to the Topical Issue "COST Action Nano-IBCT: Nano-scale Processes Behind Ion-Beam Cancer Therapy", edited by Andrey Solov'yov, Nigel Mason, Gustavo García, Eugene Surdutovich.
Detection and modeling of leakage current in AlGaN-based deep ultraviolet light-emitting diodes
Moseley, Michael William; Allerman, Andrew A.; Crawford, Mary H.; ...
2015-03-01
Current-voltage (IV) characteristics of two AlGaN-based deep ultraviolet (DUV) light-emitting diodes (LEDs) with differing densities of open-core threading dislocations (nanopipes) are analyzed. A three-diode circuit is simulated to emulate the IV characteristics of the DUV-LEDs, but is only able to accurately model the lower leakage current, lower nanopipe density DUV-LED. It was found that current leakage through the nanopipes in these structures is rectifying, despite nanopipes being previously established as inherently n-type. Using defect-sensitive etching, the nanopipes are revealed to terminate within the p-type GaN capping layer of the DUV-LEDs. The circuit model is modified to account for another p-nmore » junction between the n-type nanopipes and the p-type GaN, and an excellent fit to the IV characteristics of the leaky DUV-LED is achieved.« less
Experiments and Demonstrations in Physics: Bar-Ilan Physics Laboratory (2nd Edition)
NASA Astrophysics Data System (ADS)
Kraftmakher, Yaakov
2014-08-01
The following sections are included: * Data-acquisition systems from PASCO * ScienceWorkshop 750 Interface and DataStudio software * 850 Universal Interface and Capstone software * Mass on spring * Torsional pendulum * Hooke's law * Characteristics of DC source * Digital storage oscilloscope * Charging and discharging a capacitor * Charge and energy stored in a capacitor * Speed of sound in air * Lissajous patterns * I-V characteristics * Light bulb * Short time intervals * Temperature measurements * Oersted's great discovery * Magnetic field measurements * Magnetic force * Magnetic braking * Curie's point I * Electric power in AC circuits * Faraday's law of induction I * Self-inductance and mutual inductance * Electromagnetic screening * LCR circuit I * Coupled LCR circuits * Probability functions * Photometric laws * Kirchhoff's rule for thermal radiation * Malus' law * Infrared radiation * Irradiance and illuminance
A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism
NASA Astrophysics Data System (ADS)
Liu, Hongyu; Chen, Yao; Cho, Kyungsuk; Feng, Shiwei; Vasanth, Veluchamy; Koval, Artem; Du, Guohui; Wu, Zhao; Li, Chuanyang
2018-04-01
A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB) of this burst is extremely high, over 10^{11} K at 150 MHz and over 108 K in general. The degree of circular polarization (q) is between -60% ˜ -100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3 ˜ -4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.
OLED lighting devices having multi element light extraction and luminescence conversion layer
Krummacher, Benjamin Claus; Antoniadis, Homer
2010-11-16
An apparatus such as a light source has a multi element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.
Light Helicopter Family Trade-Off Analysis. Volume 4. Appendix N
1985-05-15
Figur«! N -V1I-9 through N -VII-U ahow th« futl flow CMp«rlsoas chac comt|>oad r.o th« powar r«qutr«««nt* thown by flguraa (J-VII-l through M-VII-4...HELICOPTER. FAMILY TRADE-OFF ANALYSIS APPENDIX N VOLUME IV ACN: 69396 • Copy l_Q] of 130 c:optea. 15 Nay 198S ~ .. 8 06 .0&1 OTIC ELECTE AU613...TITLE (- ..... do) I. TYPf ’!! ~POitT a PI!I’IOD COVI:IU!O LIGHT HELICOPTER FAMILY TRADE-OFF ANALYSIS, Fina t y Report, APPENDIX N , VOLUME IV of XI
Module Measurements | Photovoltaic Research | NREL
prototype concentrator evaluation test bed, and the Daystar DS-10/125 portable I-V curve tracer. Standard Evaluation Test Bed. We developed this test bed to be able to evaluate I-V characteristics throughout the day a function of time, temperature, and light level. This test bed data set is also used to evaluate
2015-04-01
Light Cycle Sleep, 4-8 hrs Increase mobility Consider ear plugs, sleep aid Treatment NA Dexmedetomidine drip Haloperidol IV Push... Haloperidol IV Push Quetiepine PO/Enteral Notes: CV Monitoring Standard monitoring (Tele, SpO2, RR, NBP) Maximize knowledge Standard ICU
40 CFR 65.104 - Instrument and sensory monitoring for leaks.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (i) Valves in gas/vapor service and in light liquid service shall be monitored pursuant to § 65.106(b). (ii) Pumps in light liquid service shall be monitored pursuant to § 65.107(b). (iii) Connectors in gas/vapor service and in light liquid service shall be monitored pursuant to § 65.108(b). (iv) Agitators in...
40 CFR 65.104 - Instrument and sensory monitoring for leaks.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (i) Valves in gas/vapor service and in light liquid service shall be monitored pursuant to § 65.106(b). (ii) Pumps in light liquid service shall be monitored pursuant to § 65.107(b). (iii) Connectors in gas/vapor service and in light liquid service shall be monitored pursuant to § 65.108(b). (iv) Agitators in...
Antoniadis,; Homer, Krummacher [Mountain View, CA; Claus, Benjamin [Regensburg, DE
2008-01-22
An apparatus such as a light source has a multi-element light extraction and luminescence conversion layer disposed over a transparent layer of the light source and on the exterior of said light source. The multi-element light extraction and luminescence conversion layer includes a plurality of light extraction elements and a plurality of luminescence conversion elements. The light extraction elements diffuses the light from the light source while luminescence conversion elements absorbs a first spectrum of light from said light source and emits a second spectrum of light.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahlander, Claes, E-mail: claes.fahlander@nuclear.lu.se
Two world-class research facilities, the European Spallation Source, ESS, and the light-source facility MAX-IV, are being built in southern Sweden. They will primarily, when completed, be used for research in the fields of material sciences, life sciences, medicine and pharmacology. Their construction and the operation and maintenance of them for many years will create new business opportunities for companies in Europe in general and in Sweden, Denmark and Norway in particular in many different sectors. A project, CATE, Cluster for Accelerator Technology, was set up with the aim to strengthen the skills of companies in the Öresund-Kattegat-Skagerrak region in Scandinaviamore » in the field of accelerator technology such that they will become competitive and be able to take advantage of the potential of these two research facilities. CATE was strategically important and has helped to create partnerships between companies and new business opportunities in the region.« less
NASA Astrophysics Data System (ADS)
Fahlander, Claes
2016-07-01
Two world-class research facilities, the European Spallation Source, ESS, and the light-source facility MAX-IV, are being built in southern Sweden. They will primarily, when completed, be used for research in the fields of material sciences, life sciences, medicine and pharmacology. Their construction and the operation and maintenance of them for many years will create new business opportunities for companies in Europe in general and in Sweden, Denmark and Norway in particular in many different sectors. A project, CATE, Cluster for Accelerator Technology, was set up with the aim to strengthen the skills of companies in the Öresund-Kattegat-Skagerrak region in Scandinavia in the field of accelerator technology such that they will become competitive and be able to take advantage of the potential of these two research facilities. CATE was strategically important and has helped to create partnerships between companies and new business opportunities in the region.
The BBX subfamily IV: additional cogs and sprockets to fine-tune light-dependent development.
Sarmiento, Felipe
2013-04-01
Plants depend on light during all phases of its life cycle, and have evolved a complex signaling network to constantly monitor its surroundings. Photomorphogenesis, a process during which the plant reprograms itself in order to dwell life in presence of light is one of the most studied phenomena in plants. Recent mutant analyses using model plant Arabidopsis thaliana and protein interaction assays have unraveled a new set of players, an 8-member subfamily of B-box proteins, known as BBX subfamily IV. For the members of this subfamily, positive (BBX21, BBX22) as well as negative (BBX24) functions have been described for its members, showing a strong association to two major players of the photomorphogenic cascade, HY5 and COP1. The roles of these new BBX regulators are not restricted to photomorphogenesis, but also have functions in other facets of light-dependent development. Therefore this newly identified set of regulators has opened up new insights into the understanding of the fine-tuning of this complex process.
Optical coherence tomography to evaluate the effects of oxidative hair dye on the fiber.
Velasco, Maria Valéria Robles; de Abreu, Simone Rachid Pfannemüller; de Freitas, Anderson Zanardi; Bedin, Valcinir; Baby, André Rolim; da Gama, Robson Miranda
2016-11-01
Oxidative hair dyes can damage the hair, since these chemical procedures are involved to change the fiber structure and therefore changes in their mechanical and surface properties. Evaluate and compare the effect of the two colors of oxidative hair dye emulsions on Caucasian hair. This research analyzed the Dark brown hair untreated (I); Dark brown hair treated with light brown dye (II); Dark brown hair treated with light blond dye (III); Light blond hair untreated (IV); Light blond hair treated with light brown dye (V); Light blond hair treated with light blond dye (VI) on Caucasian hair. The hair samples were submitted to breaking strength, color, and optical coherence tomography (OCT) analysis. For the breaking strength assay no presented statistically significant differences between treatments. The parameters of color and brightness can differ in some hair dye formulations, but also the hair type can respond differently. The OCT images of the sample I and IV was possible observed, clearly Medulla and Cortex, which was not observed clearly after treatment with both oxidative hair dye colors. Based on the results, the oxidative hair dyes increased alteration in color and ultrastructure of hair. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Backscatter absorption gas imaging systems and light sources therefore
Kulp, Thomas Jan [Livermore, CA; Kliner, Dahv A. V. [San Ramon, CA; Sommers, Ricky [Oakley, CA; Goers, Uta-Barbara [Campbell, NY; Armstrong, Karla M [Livermore, CA
2006-12-19
The location of gases that are not visible to the unaided human eye can be determined using tuned light sources that spectroscopically probe the gases and cameras that can provide images corresponding to the absorption of the gases. The present invention is a light source for a backscatter absorption gas imaging (BAGI) system, and a light source incorporating the light source, that can be used to remotely detect and produce images of "invisible" gases. The inventive light source has a light producing element, an optical amplifier, and an optical parametric oscillator to generate wavelength tunable light in the IR. By using a multi-mode light source and an amplifier that operates using 915 nm pump sources, the power consumption of the light source is reduced to a level that can be operated by batteries for long periods of time. In addition, the light source is tunable over the absorption bands of many hydrocarbons, making it useful for detecting hazardous gases.
Independent Validation and Verification of automated information systems in the Department of Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunteman, W.J.; Caldwell, R.
1994-07-01
The Department of Energy (DOE) has established an Independent Validation and Verification (IV&V) program for all classified automated information systems (AIS) operating in compartmented or multi-level modes. The IV&V program was established in DOE Order 5639.6A and described in the manual associated with the Order. This paper describes the DOE IV&V program, the IV&V process and activities, the expected benefits from an IV&V, and the criteria and methodologies used during an IV&V. The first IV&V under this program was conducted on the Integrated Computing Network (ICN) at Los Alamos National Laboratory and several lessons learned are presented. The DOE IV&Vmore » program is based on the following definitions. An IV&V is defined as the use of expertise from outside an AIS organization to conduct validation and verification studies on a classified AIS. Validation is defined as the process of applying the specialized security test and evaluation procedures, tools, and equipment needed to establish acceptance for joint usage of an AIS by one or more departments or agencies and their contractors. Verification is the process of comparing two levels of an AIS specification for proper correspondence (e.g., security policy model with top-level specifications, top-level specifications with source code, or source code with object code).« less
Driver circuit for solid state light sources
Palmer, Fred; Denvir, Kerry; Allen, Steven
2016-02-16
A driver circuit for a light source including one or more solid state light sources, a luminaire including the same, and a method of so driving the solid state light sources are provided. The driver circuit includes a rectifier circuit that receives an alternating current (AC) input voltage and provides a rectified AC voltage. The driver circuit also includes a switching converter circuit coupled to the light source. The switching converter circuit provides a direct current (DC) output to the light source in response to the rectified AC voltage. The driver circuit also includes a mixing circuit, coupled to the light source, to switch current through at least one solid state light source of the light source in response to each of a plurality of consecutive half-waves of the rectified AC voltage.
Low Thermal Conductance Transition Edge Sensor (TES) for SPICA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khosropanah, P.; Dirks, B.; Kuur, J. van der
2009-12-16
We fabricated and characterized low thermal conductance transition edge sensors (TES) for SAFARI instrument on SPICA. The device is based on a superconducting Ti/Au bilayer deposited on suspended SiN membrane. The critical temperature of the device is 113 mK. The low thermal conductance is realized by using long and narrow SiN supporting legs. All measurements were performed having the device in a light-tight box, which to a great extent eliminates the loading of the background radiation. We measured the current-voltage (IV) characteristics of the device in different bath temperatures and determine the thermal conductance (G) to be equal to 320more » fW/K. This value corresponds to a noise equivalent power (NEP) of 3x10{sup -19} W/{radical}(Hz). The current noise and complex impedance is also measured at different bias points at 55 mK bath temperature. The measured electrical (dark) NEP is 1x10{sup -18} W/{radical}(Hz), which is about a factor of 3 higher than what we expect from the thermal conductance that comes out of the IV curves. Despite using a light-tight box, the photon noise might still be the source of this excess noise. We also measured the complex impedance of the same device at several bias points. Fitting a simple first order thermal-electrical model to the measured data, we find an effective time constant of about 2.7 ms and a thermal capacity of 13 fJ/K in the middle of the transition.« less
VizieR Online Data Catalog: MGIV (Fourth MIT-Green Bank) 5GHz Survey (Griffith+ 1991)
NASA Astrophysics Data System (ADS)
Griffith, M.; Langston, G.; Heflin, M.; Conner, S.; Burke, B.
1998-10-01
The MIT-Green Bank IV (MG IV) 5 GHz survey covers 0.504 sr of sky in the right ascension range 15.5 to 2.5 hours, between +37.00 and +50.98 degrees declination (B1950). The final MG IV catalog contains 3427 sources detected with a signal-to-noise ratio greater than 5. The catalog was produced from two separate north and south surveys with the National Radio Astronomy Observatory (NRAO) 91m transit telescope. The north survey was produced from data collected while scanning the telescope north from +39.0 to +50.98 degrees declination and the south survey from data collected from scans from +48.98 to +37.00 degrees declination. The completeness and reliability of the final source list is checked by examination of north and south source lists in a twice observed comparison region, lying between +39.15 and +48.83 degrees declination and excluding the area between +/-10 degrees Galactic latitude. The comparison region covers 0.270 sr of sky and contains 1094 sources. In this region, the MG IV catalog contains 423 sources brighter than 90 mJy and is shown to be 99.1 +/- 1.2% complete at this flux density level. Spectral indices are computed for sources identified in the NRAO 1400 MHz Survey (published by Condon and Broderick in 1985). A comparison of the spectral index distributions between +/- 10 and outside of +/- 10 degrees Galactic latitude is presented. (1 data file).
Position Index for the Matrix Light Source
NASA Astrophysics Data System (ADS)
Takahashi, Hiroshi; Kobayashi, Yoshinori; Onda, Shou; Irikura, Takashi
It is expected that in the future white LEDs will be widely used in practical applications including replacing conventional lighting in offices and homes. The white LED light source of matrix arrangement is also considered in it. On the other hand, although now the unified glare rating (UGR) is widely used for evaluation of the discomfort glare of the interior lighting, UGR is a thing for a uniform light source, and its application to the matrix light sources that have non-uniform luminance has not been considered. The aim of this study is to clarify the position index which is one of element of UGR for the matrix light source. In this case, to apply the position index for a matrix light source to UGR, the concept of the revised position index is invented. As the preliminary experiment, method for measuring the position index was conducted, and as the experiment, position index for the matrix light source was conducted and compared with the uniform light source. The results of the experiments show that the position index is decided by the relative angle between line of sight and light source. It is also found that the matrix light source have larger position index than uniform light source. Furthermore, it is shown that the discomfort glare caused by a matrix light source can be evaluated by applying the revised position index to the UGR.
Utility and safety of a novel surgical microscope laser light source
Bakhit, Mudathir S.; Suzuki, Kyouichi; Sakuma, Jun; Fujii, Masazumi; Murakami, Yuta; Ito, Yuhei; Sugano, Tetsuo; Saito, Kiyoshi
2018-01-01
Objective Tissue injuries caused by the thermal effects of xenon light microscopes have previously been reported. Due to this, the development of a safe microscope light source became a necessity. A newly developed laser light source is evaluated regarding its effectiveness and safety as an alternative to conventional xenon light source. Methods We developed and tested a new laser light source for surgical microscopes. Four experiments were conducted to compare xenon and laser lights: 1) visual luminance comparison, 2) luminous and light chromaticity measurements, 3) examination and analysis of visual fatigue, and 4) comparison of focal temperature elevation due to light source illumination using porcine muscle samples. Results Results revealed that the laser light could be used at a lower illumination value than the xenon light (p < 0.01). There was no significant difference in visual fatigue status between the laser light and the xenon light. The laser light was superior to the xenon light regarding luminous intensity and color chromaticity. The focal temperature elevation of the muscle samples was significantly higher when irradiated with xenon light in vitro than with laser light (p < 0.01). Conclusion The newly developed laser light source is more efficient and safer than a conventional xenon light source. It lacks harmful ultraviolet waves, has a longer lifespan, a lower focal temperature than that of other light sources, a wide range of brightness and color production, and improved safety for the user’s vision. Further clinical trials are necessary to validate the impact of this new light source on the patient’s outcome and prognosis. PMID:29390016
Polymer Light-Emitting Diode (PLED) Process Development
2003-12-01
conclusions and recommendations for Phase II of the Flexible Display Program. 15. SUBJECT TERMS LIGHT EMITTING DIODES LIQUID CRYSTAL DISPLAY SYSTEMS...space for Phase I and II confined by backplane complexity and substrate form...12 Figure 6. Semi automated I-V curve measurement setup consisting of Keithley power supply, computer and
NASA Technical Reports Server (NTRS)
Bolin, Kenneth (Inventor); Flynn, David (Inventor); Fowski, Walter (Inventor); Miklus, Kenneth (Inventor); Kissh, Frank (Inventor); Abreu, Rene (Inventor)
1993-01-01
A method and apparatus for tracking a light source in a transient event rich environment locks on to a light source incident on a field-of-view 1 of a charge-coupled-device (CCD) array 6, validates the permanence of said light source and transmits data relating to the brilliance and location of said light source if said light source is determined to be permanent.
Non-contact pumping of light emitters via non-radiative energy transfer
Klimov, Victor I.; Achermann, Marc
2010-01-05
A light emitting device is disclosed including a primary light source having a defined emission photon energy output, and, a light emitting material situated near to said primary light source, said light emitting material having an absorption onset equal to or less in photon energy than the emission photon energy output of the primary light source whereby non-radiative energy transfer from said primary light source to said light emitting material can occur yielding light emission from said light emitting material.
Khalaf, Hanaa A; Arafat, Eetmad A
2015-01-01
Monosodium glutamate (MSG) is a major flavor enhancer used as a food additive. The present study investigates the effects of different doses of MSG on the morphometric and histological changes of the thyroid gland. 28 male albino rats were used. The rats were divided into four groups: group I control, group II, III and IV treated with MSG (0.25 g/kg, 3 g/kg, 6 g/kg daily for one month) respectively. The thyroid glands were dissected out and prepared for light and electron microscopic examination. Light microscopic examination of thyroid gland of group II revealed increase in follicular epithelial height. Groups III & IV showed decrease in the follicular diameter and irregularity in the shape of some follicles with discontinuity of basement membrane. Follicular hyperplasia was detected in some follicles with appearance of multiple pyknotic nuclei in follicular and interfollicular cells and multiple exfoliated cells in the colloid. In addition, areas of loss of follicular pattern were appeared in group IV. Immunohistochemical examination of BCL2 immunoexpression of the thyroid glands of groups III & IV reveals weak positive reaction in the follicular cells cytoplasm. Ultrathin sections examination of groups III & IV revealed follicular cells with irregular hyperchromatic nuclei, marked dilatation of rER and increased lysosomes with areas of short or lost apical microvilli. In addition, vacuolation of mitochondria was detected in group IV. The results displayed that MSG even at low doses is capable of producing alterations in the body weights and thyroid tissue function and histology. PMID:26884820
NASA Astrophysics Data System (ADS)
de Andrade, Rocelito Lopes; de Oliveira, Matheus Costa; Kohlrausch, Emerson Cristofer; Santos, Marcos José Leite
2018-05-01
This work presents a new and simple method for determining IPH (current source dependent on luminance), I0 (reverse saturation current), n (ideality factor), RP and RS, (parallel and series resistance) to build an electrical model for dye sensitized solar cells (DSSCs). The electrical circuit parameters used in the simulation and to generate theoretical curves for the single diode electrical model were extracted from I-V curves of assembled DSSCs. Model validation was performed by assembling five different types of DSSCs and evaluating the following parameters: effect of a TiO2 blocking/adhesive layer, thickness of the TiO2 layer and the presence of a light scattering layer. In addition, irradiance, temperature, series and parallel resistance, ideality factor and reverse saturation current were simulated.
Low-Frequency Radio Bursts and Space Weather
NASA Technical Reports Server (NTRS)
Gopalswamy, N.
2016-01-01
Low-frequency radio phenomena are due to the presence of nonthermal electrons in the interplanetary (IP) medium. Understanding these phenomena is important in characterizing the space environment near Earth and other destinations in the solar system. Substantial progress has been made in the past two decades, because of the continuous and uniform data sets available from space-based radio and white-light instrumentation. This paper highlights some recent results obtained on IP radio phenomena. In particular, the source of type IV radio bursts, the behavior of type III storms, shock propagation in the IP medium, and the solar-cycle variation of type II radio bursts are considered. All these phenomena are closely related to solar eruptions and active region evolution. The results presented were obtained by combining data from the Wind and SOHO missions.
NASA Astrophysics Data System (ADS)
Hafeez, Hafeez Y.; Iro, Zaharaddeen S.; Adam, Bala I.; Mohammed, J.
2018-04-01
An organic solar cell device or organic photovoltaic cell (OPV) is a class of solar cell that uses conductive organic polymers or small organic molecules for light absorption and charge transport. In this study, we fabricate and characterize an organic photovoltaic cell device and estimated important parameters of the device such as Open Circuit Voltage Voc of 0.28V, Short-Circuit Current Isc of 4.0 × 10-5 A, Maximum Power Pmax of 2.4 × 10-6 W, Fill Factor of 0.214 and the energy conversion efficiency of η=0.00239% were tested using Keithley 2400,source meter under A.M 1.5 (1000/m2) illumination from a Newport Class A solar simulator. Also the I-V characteristics for OPV were drawn.
Preparation and optical properties of iron-modified titanium dioxide obtained by sol-gel method
NASA Astrophysics Data System (ADS)
Hreniak, Agnieszka; Gryzło, Katarzyna; Boharewicz, Bartosz; Sikora, Andrzej; Chmielowiec, Jacek; Iwan, Agnieszka
2015-08-01
In this paper twelve TiO2:Fe powders prepared by sol-gel method were analyzed being into consideration the kind of iron compound applied. As a precursor titanium (IV) isopropoxide (TIPO) was used, while as source of iron Fe(NO3)3 or FeCl3 were tested. Fe doped TiO2 was obtained using two methods of synthesis, where different amount of iron was added (1, 5 or 10% w/w). The size of obtained TiO2:Fe particles depends on the iron compound applied and was found in the range 80-300 nm as it was confirmed by SEM technique. TiO2:Fe particles were additionally investigated by dynamic light scattering (DLS) method. Additionally, for the TiO2:Fe particles UV-vis absorption and the zeta potential were analyzed. Selected powders were additionally investigated by magnetic force microscopy (MFM) and X-ray diffraction techniques. Photocatalytic ability of Fe doped TiO2 powders was evaluated by means of cholesteryl hemisuccinate (CHOL) degradation experiment conducted under the 30 min irradiation of simulated solar light.
A New Radio Loudness Diagnostic for Active Galaxies: A Radio-to-Mid-Infrared Parameter
NASA Technical Reports Server (NTRS)
Melendez, Marcio B.; Kraemer, S. B.; Schmitt, H. R.
2010-01-01
We have studied the relationship between the nuclear (high-resolution) radio emission, at 8.4GHz (3.6cm) and 1.4GHz (20cm), the [O IV) (gamma)25.89 micron, [Ne III] (gamma)l5.56 micron and [Ne II] (gamma)l2.81 micron emission lines and the black hole mass accretion rate for a sample of Seyfert galaxies. In order to characterize the radio contribution for the Seyfert nuclei we used the 8.4 GHz/[O IV] ratio, assuming that [0 IV] scales with the luminosity of the active galactic nuclei (AGN). From this we find that Seyfert 1 s (i.e. Seyfert 1.0s, 1.2s and 1.5s) and Seyfert 2s (i.e. Seyfert 1.8s, 1.9s and 2.0s) have similar radio contributions, relative to the AGN. On the other hand, sources in which the [Ne u] emission is dominated either by the AGN or star formation have statistically different radio contributions, with star formation dominated sources more 'radio loud', by a factor of approx.2.8 on average, than AGN dominated sources. We show that star formation dominated sources with relatively larger radio contribution have smaller mass accretion rates. Overall, we suggest that 8.4 GHz/[O IV], or alternatively, 1.4 GHz/[O IV] ratios, can be used to characterize the radio contribution, relative to the AGN, without the limitation of previous methods that rely on optical observables. Key words: Galaxy: stellar content - galaxies: Seyfert - infrared: galaxies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lines, Amanda M.; Adami, Susan R.; Casella, Amanda J.
The solution chemistry of Pu in nitric acid is explored via electrochemistry and spectroelectrochemistry. By utilizing and comparing these techniques, an improved understanding of Pu behavior and its dependence on nitric acid concentration can be achieved. Here the Pu (III/IV) couple is characterized using cyclic voltammetry, square wave voltammetry, and a spectroelectrochemical Nernst step. Results indicate the formal reduction potential of the couple shifts negative with increasing acid concentration and reversible electrochemistry is no longer attainable above 6 M HNO3. Spectroelectrochemistry is also used to explore the irreversible oxidation of Pu(IV) to Pu(VI) and shine light on the mechanism andmore » acid dependence of the redox reaction.« less
Nanomechanical resonators based on group IV element monolayers
NASA Astrophysics Data System (ADS)
He, Ji-Dong; Sun, Jia-Sheng; Jiang, Jin-Wu
2018-04-01
We perform molecular dynamics simulations to investigate the energy dissipation of the resonant oscillation for the group IV monolayers of puckered configuration, in which the oscillation is driven with different actuation velocities. We find that, in the moderate actuation velocity regime, the nonlinear coupling between the resonant oscillation mode and other high-frequency modes will lead to the non-resonant motion of the system. For the larger actuation velocity, the effective strain generated during the resonant oscillating causes a structural transition from the puckered configuration into the planar configuration, which is a characteristic energy dissipation mechanism for the resonant oscillation of these group IV puckered monolayers. Our findings shed light on mechanical applications of the group IV monolayers in the nanomechanical resonator field.
Heating device for semiconductor wafers
Vosen, Steven R.
1999-01-01
An apparatus for heat treating semiconductor wafers is disclosed. The apparatus includes a heating device which contains an assembly of light energy sources for emitting light energy onto a wafer. In particular, the light energy sources are positioned such that many different radial heating zones are created on a wafer being heated. For instance, in one embodiment, the light energy sources form a spiral configuration. In an alternative embodiment, the light energy sources appear to be randomly dispersed with respect to each other so that no discernable pattern is present. In a third alternative embodiment of the present invention, the light energy sources form concentric rings. Tuning light sources are then placed in between the concentric rings of light.
Heating device for semiconductor wafers
Vosen, S.R.
1999-07-27
An apparatus for heat treating semiconductor wafers is disclosed. The apparatus includes a heating device which contains an assembly of light energy sources for emitting light energy onto a wafer. In particular, the light energy sources are positioned such that many different radial heating zones are created on a wafer being heated. For instance, in one embodiment, the light energy sources form a spiral configuration. In an alternative embodiment, the light energy sources appear to be randomly dispersed with respect to each other so that no discernible pattern is present. In a third alternative embodiment of the present invention, the light energy sources form concentric rings. Tuning light sources are then placed in between the concentric rings of light. 4 figs.
Nonimaging Optical Illumination System
Winston, Roland
1994-08-02
A nonimaging illumination optical device for producing selected intensity output over an angular range. The device includes a light reflecting surface (24, 26) around a light source (22) which is disposed opposite the aperture opening of the light reflecting surface (24, 26). The light source (22) has a characteristic dimension which is small relative to one or more of the distance from the light source (22) to the light reflecting surface (24, 26) or the angle subtended by the light source (22) at the light reflecting surface (24, 26).
NASA Technical Reports Server (NTRS)
Berghea, C. T.; Dudik, R. P.; Weaver, K. A.; Kallman, T. R.
2008-01-01
We present the first Spitzer Infrared Spectrograph (IRS) observations of the [O IV] 25.89 micron emission line detected from the ultraluminous X-ray source (ULX) in Holmberg II. This line is a well established signature of high excitation, usually associated with AGN. Its detection suggests that the ULX has a strong impact on the surrounding gas. A Spitzer high resolution spectral map shows that the [O IV] is coincident with the X-ray position of the Holmberg II ULX. We find that the luminosity and the morphology of the line emission is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is radiation bounded both in the line of sight direction and to the west, and probably matter bounded to the east. Evidence for a massive black hole (BH) in this ULX is mounting. Detailed photoionization models favor an intermediate mass black hole of at least 85 Solar Mass as the ionization source for the [OIV] emission. We find that the spectral type of the companion star strongly affects the expected strength of the [O IV] emission. This finding could explain the origin of [O IV] in some starburst galaxies containing black hole binaries.
Development of a circadian light source
NASA Astrophysics Data System (ADS)
Nicol, David B.; Ferguson, Ian T.
2002-11-01
Solid state lighting presents a new paradigm for lighting - controllability. Certain characteristics of the lighting environment can be manipulated, because of the possibility of using multiple LEDs of different emission wavelengths as the illumination source. This will provide a new, versatile, general illumination source due to the ability to vary the spectral power distribution. New effects beyond the visual may be achieved that are not possible with conventional light sources. Illumination has long been the primary function of lighting but as the lighting industry has matured the psychological aspects of lighting have been considered by designers; for example, choosing a particular lighting distribution or color variation in retail applications. The next step in the evolution of light is to consider the physiological effects of lighting that cause biological changes in a person within the environment. This work presents the development of a source that may have important bearing on this area of lighting. A circadian light source has been developed to provide an illumination source that works by modulating its correlated color temperature to mimic the changes in natural daylight through the day. In addition, this source can cause or control physiological effects for a person illuminated by it. The importance of this is seen in the human circadian rhythm's peak response corresponding to blue light at ~460 nm which corresponds to the primary spectral difference in increasing color temperature. The device works by adding blue light to a broadband source or mixing polychromatic light to mimic the variation of color temperature observed for the Planckian Locus on the CIE diagram. This device can have several applications including: a tool for researchers in this area, a general illumination lighting technology, and a light therapy device.
A tuneable approach to uniform light distribution for artificial daylight photodynamic therapy.
O'Mahoney, Paul; Haigh, Neil; Wood, Kenny; Brown, C Tom A; Ibbotson, Sally; Eadie, Ewan
2018-06-16
Implementation of daylight photodynamic therapy (dPDT) is somewhat limited by variable weather conditions. Light sources have been employed to provide artificial dPDT indoors, with low irradiances and longer treatment times. Uniform light distribution across the target area is key to ensuring effective treatment, particularly for large areas. A novel light source is developed with tuneable direction of light emission in order to meet this challenge. Wavelength composition of the novel light source is controlled such that the protoporphyrin-IX (PpIX) weighed spectra of both the light source and daylight match. The uniformity of the light source is characterised on a flat surface, a model head and a model leg. For context, a typical conventional PDT light source is also characterised. Additionally, the wavelength uniformity across the treatment site is characterised. The PpIX-weighted spectrum of the novel light source matches with PpIX-weighted daylight spectrum, with irradiance values within the bounds for effective dPDT. By tuning the direction of light emission, improvements are seen in the uniformity across large anatomical surfaces. Wavelength uniformity is discussed. We have developed a light source that addresses the challenges in uniform, multiwavelength light distribution for large area artificial dPDT across curved anatomical surfaces. Copyright © 2018. Published by Elsevier B.V.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You
1997-01-01
This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor (50). An optical fiber micro-light source (50) is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors (22) in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material (60). This process allows significant control of the size of the micro light source (50). Furthermore, photo-chemically attaching an optically active material (60) enables the implementation of the micro-light source in a variety of sensor applications.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You
1994-01-01
This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, R.; Tan, W.; Shi, Z.Y.
1997-05-06
This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 10 figs.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, R.; Tan, W.; Shi, Z.Y.
1994-11-01
This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 4 figs.
Bilgihan, Kamil; Yuksel, Erdem; Deniz, Nuriye Gokcen; Yuksel, Nilay
2015-01-01
Corneal collagen cross linking (CCL) with ultraviolet A (UVA) has been proposed as a treatment for the progression of corneal ectasia associated with keratoconus and post-laser-assisted in situ keratomileusis (LASIK) ectasia. Despite the reports about safety of procedure, we consider that UVA of sunlight can effect riboflavin saturated and de-epitelizated cornea early after CCL. To evaluate the UVA blockage capability of 11 different silicone hydrogel contact lenses which are widely used after CCL treatment. Eleven different silicone hydrogel and daily disposable contact lenses were evaluated. The UVA light at 365 nm wavelength for UVA source and UV light meter to measure UVA radiation were used. 3, 9 and 18 mW/cm(2) power of UV radiance was applied centrally to the each type of contact lenses. The power of UVA transmittance for each radiance and percentage of blockage were evaluated for each brand. Also, protection factor (PF) was calculated. The senofilcon A and narafilcon A had the highest blockage and lowest transmittance (p = 0.02). PF was significantly higher in the senofilcon A and narafilcon A at 3, 9 and 18 mW/cm(2) (p = 0.0001). And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B had the highest UVA transmittance. The narafilcon A and the senofilcon A may be a good options for epithelial healing after CCL procedure to protect the cornea from UVA of sunlight. And also, the hilafilcon B, filcon IV, nelfilcon A, enfilcon A, lotrafilcon A and lotrafilcon B contact lenses that have high-UVA transmittance feature can be a treatment choice for contact lens-assisted CCL technique in thin corneas.
LED intense headband light source for fingerprint analysis
Villa-Aleman, Eliel
2005-03-08
A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF... NOX value achieved; and (iv) All values used in calculating the fleet average NOX value achieved. (2...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF... NOX value achieved; and (iv) All values used in calculating the fleet average NOX value achieved. (2...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF... NOX value achieved; and (iv) All values used in calculating the fleet average NOX value achieved. (2...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF... NOX value achieved; and (iv) All values used in calculating the fleet average NOX value achieved. (2...
Spectral design flexibility of LED brings better life
NASA Astrophysics Data System (ADS)
Ou, Haiyan; Corell, Dennis; Ou, Yiyu; Poulsen, Peter B.; Dam-Hansen, Carsten; Petersen, Paul-Michael
2012-03-01
Light-emitting diodes (LEDs) are penetrating into the huge market of general lighting because they are energy saving and environmentally friendly. The big advantage of LED light sources, compared to traditional incandescent lamps and fluorescent light tubes, is the flexible spectral design to make white light using different color mixing schemes. The spectral design flexibility of white LED light sources will promote them for novel applications to improve the life quality of human beings. As an initial exploration to make use of the spectral design flexibility, we present an example: 'no blue' white LED light source for sufferers of disease Porphyria. An LED light source prototype, made of high brightness commercial LEDs applying an optical filter, was tested by a patient suffering from Porphyria. Preliminary results have shown that the sufferer could withstand the light source for much longer time than the standard light source. At last future perspectives on spectral design flexibility of LED light sources improving human being's life will be discussed, with focus on the light and health. The good health is ensured by the spectrum optimized so that vital hormones (melatonin and serotonin) are produced during times when they support human daily rhythm.
Simmons, Blake A [San Francisco, CA; Talin, Albert Alec [Livermore, CA
2009-11-27
A method for producing metal nanoparticles that when associated with an analyte material will generate an amplified SERS spectrum when the analyte material is illuminated by a light source and a spectrum is recorded. The method for preparing the metal nanoparticles comprises the steps of (i) forming a water-in-oil microemulsion comprising a bulk oil phase, a dilute water phase, and one or more surfactants, wherein the water phase comprises a transition metal ion; (ii) adding an aqueous solution comprising a mild reducing agent to the water-in-oil microemulsion; (iii) stirring the water-in-oil microemulsion and aqueous solution to initiate a reduction reaction resulting in the formation of a fine precipitate dispersed in the water-in-oil microemulsion; and (iv) separating the precipitate from the water-in-oil microemulsion.
Hydrogenated nanostructure boron doped amorphous carbon films by DC bias
NASA Astrophysics Data System (ADS)
Ishak, A.; Dayana, K.; Saurdi, I.; Malek, M. F.; Rusop, M.
2018-03-01
Hydrogenated nanostructure-boron doped amorphous carbon thin film carbon was deposited at different negative bias using custom-made deposition bias assisted-CVD. Solid of boron and palm oil were used as dopant and carbon source, respectively. The hydrogenated nanostructure amorphous films were characterized by Field emission scanning electron microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy, while the photo-response studies of thin film is done by I-V measurement under light measurement. The results showed the carbon film were in nanostructure with hydrogen and boron might be incorporated in the film. The Raman spectra observed the increase of upward shift of D and G peaks as negative bias increased which related to the structural change as boron incorporated in carbon network. These structural changes were further correlated with photo-response study and the results obtained are discussed and compared.
Robertson, J. Brian; Zhang, Yunfei; Johnson, Carl Hirschie
2009-01-01
Summary Light-emitting diodes (LEDs) are becoming more commonly used as light sources for fluorescence microscopy. We describe the adaptation of a commercially available LED flashlight for use as a source for fluorescence excitation. This light source is long-lived, inexpensive, and is effective for excitation in the range of 440–600 nm. PMID:19772530
Method for separating actinides. [Patent application; stripping of Np from organic extractant
Friedman, H.A.; Toth, L.M.
1980-11-10
An organic solution used for processing spent nuclear reactor fuels is contacted with an aqueous nitric acid solution to strip Np(VI), U(VI), and Pu(IV) from the organic solution into the acid solution. The acid solution is exposed to ultraviolet light, which reduces Np(VI) to Np(V) without reducing U(VI) and Pu(IV). Since the solubility of Np(V) in the organic solution is much lower than that of Np(VI), U(VI), and Pu(IV), a major part of the Np is stripped from the organic solution while leaving most of the U and Pu therein.
Kellner, T A; Prusa, K J; Patience, J F
2014-12-01
The increased inclusion of unsaturated fats in pig diets has raised issues related to pork carcass fat quality. The objective of this experiment was to more precisely measure how differing levels of daily fatty acid intake alters the fatty acid composition in 3 different fat depots. A total of 42 gilts and 21 barrows (PIC 337×C22/29) with an average initial weight of 77.80±0.38 kg were allotted randomly based on sex and BW to 7 treatments: 3 and 6% of each of tallow (TAL; iodine value [IV]=41.9), choice white grease (CWG; IV=66.5), or corn oil (CO; IV=123.1) and a control (CNTR) corn-soybean meal-based diet with no added fat. Pigs were individually housed to allow accurate measurement of individual feed intake, in particular, daily dietary fatty acid and energy intake. Fat samples were collected from the jowl, belly, and loin at slaughter. Diet and carcass fat samples were analyzed for IV. Belly weights were recorded at slaughter along with a subjective belly firmness score (1=firmest to 3=least firm). Carcass lipid IV was increased (P<0.001) by increasing the degree of unsaturation of the dietary fat source (66.8, 70.3, and 76.3 for TAL, CWG, and CO, respectively). Carcass lipid IV for TAL and CWG was not affected (P>0.05) by inclusion levels; however, carcass lipid IV was greater (P<0.001) in pigs fed 6 than 3% CO (80.0 vs. 72.6), and carcasses of gilts had greater IV (P<0.001) than carcasses of barrows (71.5 vs. 69.1). Increasing the level of TAL and CO but not CWG from 3 to 6% decreased the apparent total tract digestibility of GE, resulting in a source×level interaction (P<0.05). Dietary fat source had no effect (P≥0.66) on apparent total tract digestibility of either DM or GE, but feeding 6% dietary fat increased G:F (P=0.006) over pigs fed 3% fat (0.358 vs. 0.337). Of all the fatty acids measured, only linoleic acid intake presented a reasonable coefficient of determination (R2=0.61). Overall, IV product (IVP) was approximately equal to linoleic acid intake as a predictor of carcass IV (R2=0.93 vs. R2=0.94). When inclusion of dietary fat and PUFA intake increased, IVP placed more emphasis on the dietary fat inclusion level rather than the dietary fat composition. Linoleic acid intake corrected the overemphasis placed on dietary fat inclusion by IVP. To conclude, linoleic acid intake showed a strong relationship with carcass IV and can be used as a predictor.
USDA-ARS?s Scientific Manuscript database
Multi-layer vertical production systems using sole-source (SS) lighting can be used for microgreen production; however, traditional SS lighting can consume large amounts of electrical energy. Light-emitting diodes (LEDs) offer many advantages over conventional light sources including: high photoelec...
Galvez, Miguel; Grossman, Kenneth; Betts, David
2013-11-12
There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.
Fleming, James G [Albuquerque, NM; Lin, Shawn-Yu [Albuquerque, NM; Bur, James A [Corrales, NM
2004-07-27
A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.
A compact, coherent light source system architecture
NASA Astrophysics Data System (ADS)
Biedron, S. G.; Dattoli, G.; DiPalma, E.; Einstein, J.; Milton, S. V.; Petrillo, V.; Rau, J. V.; Sabia, E.; Spassovsky, I. P.; van der Slot, P. J. M.
2016-09-01
Our team has been examining several architectures for short-wavelength, coherent light sources. We are presently exploring the use and role of advanced, high-peak power lasers for both accelerating the electrons and generating a compact light source with the same laser. Our overall goal is to devise light sources that are more accessible by industry and in smaller laboratory settings. Although we cannot and do not want to compete directly with sources such as third-generation light sources or that of national-laboratory-based free-electron lasers, we have several interesting schemes that could bring useful and more coherent, short-wavelength light source to more researchers. Here, we present and discuss several results of recent simulations and our future steps for such dissemination.
Intense X-ray and EUV light source
Coleman, Joshua; Ekdahl, Carl; Oertel, John
2017-06-20
An intense X-ray or EUV light source may be driven by the Smith-Purcell effect. The intense light source may utilize intense electron beams and Bragg crystals. This may allow the intense light source to range from the extreme UV range up to the hard X-ray range.
Carambola optics for recycling of light.
Leutz, Ralf; Fu, Ling; Ries, Harald
2006-04-20
Recycling of light allows the luminance (radiance) emitted by a light source to be increased at the cost of reducing the total luminous flux (radiant power). Recycling of light means returning part of the emitted light to the source, where part of it will escape absorption. An optical design that is suitable for multiple and controlled recycling is described. Carambola optics is named for its resemblance to star fruit. Several pairs of mirrors or prisms redirect light repeatedly onto the source, thus achieving multiple transits of the light through the source. This recycled light exits the carambola in the same phase space as light directly emitted and not recycled.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2015-02-24
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2015-08-25
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton; Stecher, Thomas; Seeley, Charles; Kuenzler, Glenn; Wolfe, Jr., Charles; Utturkar, Yogen; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2013-05-07
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Lighting system with thermal management system
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Seeley, Charles Erklin; Kuenzler, Glenn Howard; Wolfe, Jr, Charles Franklin; Utturkar, Yogen Vishwas; Sharma, Rajdeep; Prabhakaran, Satish; Icoz, Tunc
2016-10-11
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system is configured to provide an air flow, such as a unidirectional air flow, through the housing structure in order to cool the light source. The driver electronics are configured to provide power to each of the light source and the thermal management system.
Assessment of the actual light dose in photodynamic therapy.
Schaberle, Fabio A
2018-06-09
Photodynamic therapy (PDT) initiates with the absorption of light, which depends on the spectral overlap between the light source emission and the photosensitizer absorption, resulting in the number of photons absorbed, the key parameter starting PDT processes. Most papers report light doses regardless if the light is only partially absorbed or shifted relatively to the absorption peak, misleading the actual light dose value and not allowing quantitative comparisons between photosensitizers and light sources. In this manuscript a method is presented to calculate the actual light dose delivered by any light source for a given photosensitizer. This method allows comparing light doses delivered for any combination of light source (broad or narrow band or daylight) and photosensitizer. Copyright © 2018. Published by Elsevier B.V.
Ahmad, Azeem; Dubey, Vishesh; Singh, Gyanendra; Singh, Veena; Mehta, Dalip Singh
2016-04-01
In this Letter, we demonstrate quantitative phase imaging of biological samples, such as human red blood cells (RBCs) and onion cells using narrow temporal frequency and wide angular frequency spectrum light source. This type of light source was synthesized by the combined effect of spatial, angular, and temporal diversity of speckle reduction technique. The importance of using low spatial and high temporal coherence light source over the broad band and narrow band light source is that it does not require any dispersion compensation mechanism for biological samples. Further, it avoids the formation of speckle or spurious fringes which arises while using narrow band light source.
Lease vs. Purchase Analysis of Alternative Fuel Vehicles in the United States Marine Corps
2009-12-01
data (2004 to 2009) for the largest populations of AFVs in the light-duty category and then apply a model that will compare the two alternatives based...the largest populations of AFVs in the light-duty category and then apply a model that will compare the two alternatives based on their relative net...28 IV. THE MODEL
Lease VS Purchase Analysis of Alternative Fuel Vehicles in the United States Marine Corps
2009-10-30
the light-duty category and then apply a model that will compare the two alternatives based on their relative net present values. An aggregated view of... model that will compare the two alternatives based on their relative net present values. An aggregated view of several different light-duty AFV...Summary .......................................................................................32 IV. The Model
Wu, Bobo; Shen, Xianbao; Cao, Xinyue; Yao, Zhiliang; Wu, Yunong
2016-05-01
The composition of diesel exhaust fine particulate matter (PM2.5) is of growing interest because of its impacts on health and climatic factors and its application in source apportionment and aerosol modeling. We characterized the detailed chemical composition of the PM2.5, including the organic carbon (OC), elemental carbon (EC), water-soluble ions (WSIs), and elemental contents, emitted from China III and China IV diesel trucks (nine each) based on real-world measurements in Beijing using a portable emissions measurement system (PEMS). Carbonaceous compounds were the dominant components (totaling approximately 87%) of the PM2.5, similar to the results (greater than 80% of the PM2.5) of our previous study of on-road China III diesel trucks. In general, the amounts of individual component groups (carbonaceous compounds, WSIs, and elements) and PM2.5 emissions for China IV diesel trucks were lower than those of China III diesel trucks of the same size, except for the WSIs and elements for the light- and medium-duty diesel trucks. The EC/OC mass ratios were strongly dependent on the emission standards, and the ratios of China IV diesel trucks were higher than those of China III diesel trucks of the same size. The chemical species in the PM2.5 were significantly affected by the driving conditions. Overall, the emission factors (EFs) of the PM2.5 and OC under non-highway (NHW) driving conditions were higher than those under highway (HW) driving conditions, and the EC/OC mass ratios presented an increasing trend, with decreasing OC/PM2.5 and increasing EC/PM2.5 from NHW to HW driving conditions; similar trends were reported in our previous study. In addition, Pearson's correlation coefficients among the PM2.5 species were analyzed to determine the relationships among the various chemical components. Copyright © 2016 Elsevier B.V. All rights reserved.
A novel amblyopia treatment system based on LED light source
NASA Astrophysics Data System (ADS)
Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling
2011-05-01
A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.
A novel amblyopia treatment system based on LED light source
NASA Astrophysics Data System (ADS)
Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling
2010-12-01
A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.
The Inverse-Square Law with Data Loggers
ERIC Educational Resources Information Center
Bates, Alan
2013-01-01
The inverse-square law for the intensity of light received at a distance from a light source has been verified using various experimental techniques. Typical measurements involve a manual variation of the distance between a light source and a light sensor, usually by sliding the sensor or source along a bench, measuring the source-sensor distance…
Colors of attraction: Modeling insect flight to light behavior.
Donners, Maurice; van Grunsven, Roy H A; Groenendijk, Dick; van Langevelde, Frank; Bikker, Jan Willem; Longcore, Travis; Veenendaal, Elmar
2018-06-26
Light sources attract nocturnal flying insects, but some lamps attract more insects than others. The relation between the properties of a light source and the number of attracted insects is, however, poorly understood. We developed a model to quantify the attractiveness of light sources based on the spectral output. This model is fitted using data from field experiments that compare a large number of different light sources. We validated this model using two additional datasets, one for all insects and one excluding the numerous Diptera. Our model facilitates the development and application of light sources that attract fewer insects without the need for extensive field tests and it can be used to correct for spectral composition when formulating hypotheses on the ecological impact of artificial light. In addition, we present a tool allowing the conversion of the spectral output of light sources to their relative insect attraction based on this model. © 2018 Wiley Periodicals, Inc.
Geometrical analysis of an optical fiber bundle displacement sensor
NASA Astrophysics Data System (ADS)
Shimamoto, Atsushi; Tanaka, Kohichi
1996-12-01
The performance of a multifiber optical lever was geometrically analyzed by extending the Cook and Hamm model [Appl. Opt. 34, 5854-5860 (1995)] for a basic seven-fiber optical lever. The generalized relationships between sensitivity and the displacement detection limit to the fiber core radius, illumination irradiance, and coupling angle were obtained by analyses of three various types of light source, i.e., a parallel beam light source, an infinite plane light source, and a point light source. The analysis of the point light source was confirmed by a measurement that used the light source of a light-emitting diode. The sensitivity of the fiber-optic lever is inversely proportional to the fiber core radius, whereas the receiving light power is proportional to the number of illuminating and receiving fibers. Thus, the bundling of the finer fiber with the larger number of illuminating and receiving fibers is more effective for improving sensitivity and the displacement detection limit.
Behavioural responses of krill and cod to artificial light in laboratory experiments
Løkkeborg, S.; Humborstad, O-B.
2018-01-01
Most fishes and crustaceans respond to light, and artificial light sources may therefore be an efficient stimulus to manipulate behaviours in aquatic animals. It has been hypothesised that the catch efficiency of pots could be increased if prey, for example krill, can be attracted into the pots providing a visual stimulus and a source of live bait. To find which light characteristics are most attractive to krill, we tested the effects of light intensity and wavelength composition on Northern krill’s (Meganyctiphanes norvegica) behavioural response to an artificial light source. The most attractive individual wavelength was 530 nm (green light), while broadband (425–750 nm) white light was an equally attractive light source. The intensity of the emitted light did not appear to have a direct effect on attraction to the light source, however it did significantly increase swimming activity among the observed krill. The most promising light stimuli for krill were tested to determine whether they would have a repulsive or attractive effect on cod (Gadus morhua); These light stimuli appeared to have a slightly repulsive, but non-significant, effect on cod. However, we suggest that a swarm of krill attracted to an artificial light source may produce a more effective visual stimulus to foraging cod. PMID:29370231
Behavioural responses of krill and cod to artificial light in laboratory experiments.
Utne-Palm, A C; Breen, M; Løkkeborg, S; Humborstad, O-B
2018-01-01
Most fishes and crustaceans respond to light, and artificial light sources may therefore be an efficient stimulus to manipulate behaviours in aquatic animals. It has been hypothesised that the catch efficiency of pots could be increased if prey, for example krill, can be attracted into the pots providing a visual stimulus and a source of live bait. To find which light characteristics are most attractive to krill, we tested the effects of light intensity and wavelength composition on Northern krill's (Meganyctiphanes norvegica) behavioural response to an artificial light source. The most attractive individual wavelength was 530 nm (green light), while broadband (425-750 nm) white light was an equally attractive light source. The intensity of the emitted light did not appear to have a direct effect on attraction to the light source, however it did significantly increase swimming activity among the observed krill. The most promising light stimuli for krill were tested to determine whether they would have a repulsive or attractive effect on cod (Gadus morhua); These light stimuli appeared to have a slightly repulsive, but non-significant, effect on cod. However, we suggest that a swarm of krill attracted to an artificial light source may produce a more effective visual stimulus to foraging cod.
The Correlated Variations of {\\rm{C}}\\,{\\rm{IV}} Narrow Absorption Lines and Quasar Continuum
NASA Astrophysics Data System (ADS)
Chen, Zhi-Fu; Pang, Ting-Ting; He, Bing; Huang, Yong
2018-06-01
We assemble 207 variable quasars from the Sloan Digital Sky Survey, all with at least 3 observations, to analyze C IV narrow absorption doublets, and obtain 328 C IV narrow absorption line systems. We find that 19 out of 328 C IV narrow absorption line systems were changed by | {{Δ }}{W}rλ 1548| ≥slant 3{σ }{{Δ }{W}rλ 1548} on timescales from 15.9 to 1477 days at rest-frame. Among the 19 obviously variable C IV systems, we find that (1) 14 systems have relative velocities {\\upsilon }r> 0.01c and 4 systems have {\\upsilon }r> 0.1c, where c is the speed of light; (2) 13 systems are accompanied by other variable C IV systems; (3) 9 systems were changed continuously during multiple observations; and (4) 1 system with {\\upsilon }r = 16,862 km s‑1 was enhanced by {{Δ }}{W}rλ 1548=2.7{σ }{{Δ }{W}rλ 1548} in 0.67 day at rest-frame. The variations of absorption lines are inversely correlated with the changes in the ionizing continuum. We also find that large variations of C IV narrow absorption lines are form differently over a short timescale.
High efficiency light source using solid-state emitter and down-conversion material
Narendran, Nadarajah; Gu, Yimin; Freyssinier, Jean Paul
2010-10-26
A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.
Enhanced chemiluminescence of cerium(IV)-Tween 85 system and the analytical application.
Li, Shifeng; Qian, Li; Zhu, Yan; Liu, Manman; Gao, Yinping; Ni, Yonghong
2013-01-01
The oxidation reaction between cerium(IV) and Tween 85 in sulfuric acid medium produced weak chemiluminescence (CL). In this paper, it was found that citrate could strongly enhance the CL of cerium(IV)-Tween 85-polyphenol system. Based on studies of ultraviolet-visible spectra and CL spectra, the CL enhancement mechanism had been proposed. It was surmised that the light emission was from an excited oxygen molecular pair O2((1)Δg)O2((1)∑g(-)). The maximum emission wavelength was about 478 nm. The effects of 17 amino acids and 29 organic compounds on cerium(IV)-Tween 85-citrate CL were investigated by a flow injection procedure. This study showed the present system had a wide application for the determination of these compounds. Copyright © 2012 John Wiley & Sons, Ltd.
OSO 8 observations of wave propagation in the solar chromosphere and transition region
NASA Technical Reports Server (NTRS)
Chipman, E. G.
1978-01-01
The University of Colorado instrument on OSO 8 has been used to observe relative phases of the 300-s intensity variation between the temperature-minimum region and several emission lines formed in the solar chromosphere and chromosphere-corona transition region. The lines used are due to Fe II, Si II, C II, Si IV, and C IV. The scattered light in the spectrograph, which originates almost entirely in the spectral region between 1700 and 1900 A, was used as a probe of the temperature-minimum region. The lines of Fe II, Si II, and C II show almost identical delays of approximately 30 s relative to the temperature minimum, while the intensity oscillations of the lines of Si IV and C IV appear to lead the temperature-minimum intensity oscillations by about 10 s.
Silicon micromachined broad band light source
NASA Technical Reports Server (NTRS)
George, Thomas (Inventor); Jones, Eric (Inventor); Tuma, Margaret L. (Inventor); Eastwood, Michael (Inventor); Hansler, Richard (Inventor)
2004-01-01
A micro electromechanical system (MEMS) broad band incandescent light source includes three layers: a top transmission window layer; a middle filament mount layer; and a bottom reflector layer. A tungsten filament with a spiral geometry is positioned over a hole in the middle layer. A portion of the broad band light from the heated filament is reflective off the bottom layer. Light from the filament and the reflected light of the filament are transmitted through the transmission window. The light source may operate at temperatures of 2500 K or above. The light source may be incorporated into an on board calibrator (OBC) for a spectrometer.
A two-metric proposal to specify the color-rendering properties of light sources for retail lighting
NASA Astrophysics Data System (ADS)
Freyssinier, Jean Paul; Rea, Mark
2010-08-01
Lighting plays an important role in supporting retail operations, from attracting customers, to enabling the evaluation of merchandise, to facilitating the completion of the sale. Lighting also contributes to the identity, comfort, and visual quality of a retail store. With the increasing availability and quality of white LEDs, retail lighting specifiers are now considering LED lighting in stores. The color rendering of light sources is a key factor in supporting retail lighting goals and thus influences a light source's acceptance by users and specifiers. However, there is limited information on what consumers' color preferences are, and metrics used to describe the color properties of light sources often are equivocal and fail to predict preference. The color rendering of light sources is described in the industry solely by the color rendering index (CRI), which is only indirectly related to human perception. CRI is intended to characterize the appearance of objects illuminated by the source and is increasingly being challenged because new sources are being developed with increasingly exotic spectral power distributions. This paper discusses how CRI might be augmented to better use it in support of the design objectives for retail merchandising. The proposed guidelines include the use of gamut area index as a complementary metric to CRI for assuring good color rendering.
Development of a Novel Wireless Electric Power Transfer System for Space Applications
NASA Technical Reports Server (NTRS)
VazquezRamos, Gabriel; Yuan, Jiann-Shiun
2011-01-01
This paper will introduce a new implementation for wireless electric power transfer systems: space applications. Due to the risks that constitute the use of electrical connector for some space missions/applications, a simple wireless power system design approach will be evaluated as an alternative for the use of electrical connectors. This approach takes into consideration the overall system performance by designing the magnetic resonance elements and by verifying the overall system electrical behavior. System characterization is accomplished by executing circuit and analytical simulations using Matlab(TradeMark) and LTSpiceIV(TradeMark) software packages. The design methodology was validated by two different experiments: frequency consideration (design of three magnetic elements) and a small scale proof-ofconcept prototype. Experiment results shows successful wireless power transfer for all the cases studied. The proof-of-concept prototype provided approx.4 W of wireless power to the load (light bulb) at a separation of 3 cm from the source. In addition. a resonant circuit was designed and installed to the battery terminals of a handheld radio without batteries, making it tum on at a separation of approx.5 cm or less from the source. It was also demonstrated by prototype experimentation that multiple loads can be powered wirelessly at the same time with a single electric power source.
Effect of laser speckle on light from laser diode-pumped phosphor-converted light sources.
Aquino, Felipe; Jadwisienczak, Wojciech M; Rahman, Faiz
2017-01-10
Laser diode (LD) pumped white light sources are being developed as an alternative to light-emitting diode-pumped sources for high efficiency and/or high brightness applications. While several performance metrics of laser-pumped phosphor-converted light sources have been investigated, the effect of laser speckle has not been sufficiently explored. This paper describes our experimental studies on how laser speckle affects the behavior of light from laser-excited phosphor lamps. A single LD pumping a phosphor plate was the geometry explored in this work. Overall, our findings are that the down-converted light did not exhibit any speckle, whereas speckle was present in the residual pump light but much reduced from that in direct laser light. Furthermore, a thicker coating of small-grained phosphors served to effectively reduce speckle through static pump light diffusion in the phosphor coating. Our investigations showed that speckle is not of concern in illumination from LD-pumped phosphor-converted light sources.
Efficacy of Veinlite PEDI in Pediatric Peripheral Intravenous Access: A Randomized Controlled Trial.
Gümüş, Merve; Başbakkal, Zümrüt
2018-05-23
A previous study by Katsogridakis et al (Pediatr Emerg Care. 2008;24:83-88) evaluated the use of the white light Veinite transillumination device to improve vein access in children. Since then, advanced light emitting diode color lighting has been developed to improve the visualization of veins. To evaluate the efficacy of the new technology, we carried out a study in our pediatric emergency departments using the light emitting diode-based Veinlite PEDI (TransLite, Sugar Land, Tex). A total of 112 pediatric patients were enrolled in the study. Children who presented to the emergency department aged 1 to 10 years old were randomly assigned to the Veinlite PEDI (Veinlite) group or standard of care (SoC) group. The primary outcome measure was first attempt success. Secondary outcome measures were number of intravenous (IV) attempts and time to peripheral intravenous catheter (PIC) placement. A total of 110 patients completed the study: 58 boys and 52 girls. The first attempt success rate was significantly higher in the Veinlite group compared with the SoC group (92.9% vs 72.2%, P < 0.004). In addition, the Veinlite group had a fewer number of attempts compared with the SoC group (1.07 ± 0.54 vs 1.31 ± 0.25, P = 0.04). The Veinlite group resulted in a shorter total time of attempts per patient compared with the SoC group (49.98 ± 18.4 vs 59.68 ± 22.5 P = 0.01). The use of new technology in the Veinlite PEDI (TransLite, Sugar Land, Tex), to assist with peripheral IV access in children, improves the first time success rate for IV access. Improved visualization of veins also reduced the number of attempts and the time required for PIC placement. These results suggest that the new technology of the Veinlite results in better PIC access than Veinlite transilluminaton device with white light.
Evaluating white LEDs for outdoor landscape lighting application
NASA Astrophysics Data System (ADS)
Shakir, Insiya; Narendran, Nadarajah
2002-11-01
A laboratory experiment was conducted to understand the acceptability of different white light emitting diodes (LEDs) for outdoor landscape lighting. The study used a scaled model setup. The scene was designed to replicate the exterior of a typical upscale suburban restaurant including the exterior facade of the building, an approach with steps, and a garden. The lighting was designed to replicate light levels commonly found in nighttime outdoor conditions. The model had a central dividing partition with symmetrical scenes on both sides for side-by-side evaluations of the two scenes with different light sources. While maintaining equal luminance levels and distribution between the two scenes, four types of light sources were evaluated. These include, halogen, phosphor white LED, and two white light systems using RGB LEDs. These light sources were tested by comparing two sources at a time placed side-by-side and by individual assessment of each lighting condition. The results showed that the RGB LEDs performed equal or better than the most widely used halogen light source in this given setting. A majority of the subjects found slightly dimmer ambient lighting to be more typical for restaurants and therefore found RGB LED and halogen light sources to be more inviting. The phosphor white LEDs made the space look brighter, however a majority of the subjects disliked them.
Study on Formulation of Optimum Lighting-system for Purchasing Power at Stores
NASA Astrophysics Data System (ADS)
Fujita, Hiroki; Nakashima, Yoshio; Takamatsu, Mamoru; Oota, Masaaki; Sawa, Kazuhiro
In store lighting, difference in the look-and-feel of foods gives effects on the purchasing power of customers. This study conducted the digitalization and quantification on the effects of the variation of light-source color and illuminance used for lighting foods on image recognition on foods. As a result, it was clarified that when meat was illuminated with the light source of “pink” or “faint pink,” image evaluation on foods became higher. In addition, when illuminance increase was applied to these two light-source colors, image evaluation on “faint pink” became further higher. The reason is supposed to be that the redness of meat increased, which may have enhanced fresher impression. From this study, it has been clarified that the light-source color and illuminance optimum for each food are variant. The results show that lighting foods with the optimum light-source color and illuminance can make foods look better.
Light source comprising a common substrate, a first led device and a second led device
Choong, Vi-En
2010-02-23
At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D.M. McEligot; K. G. Condie; G. E. McCreery
2005-10-01
Background: The ultimate goal of the study is the improvement of predictive methods for safety analyses and design of Generation IV reactor systems such as supercritical water reactors (SCWR) for higher efficiency, improved performance and operation, design simplification, enhanced safety and reduced waste and cost. The objective of this Korean / US / laboratory / university collaboration of coupled fundamental computational and experimental studies is to develop the supporting knowledge needed for improved predictive techniques for use in the technology development of Generation IV reactor concepts and their passive safety systems. The present study emphasizes SCWR concepts in the Generationmore » IV program.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE THEFT PREVENTION STANDARD § 541.3 Application. (a) Except... high theft in accordance with 49 CFR 542.1; and (iv) Light duty trucks with a gross vehicle weight...
24 CFR 3280.202 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-04-01
... room or space not more than 32 square feet in surface area, whichever is less; (10) Plastic light... center; (ii) Non-structural lattice work; (iii) Mating and closure molding; and (iv) Other items not...
DUV light source availability improvement via further enhancement of gas management technologies
NASA Astrophysics Data System (ADS)
Riggs, Daniel J.; O'Brien, Kevin; Brown, Daniel J. W.
2011-04-01
The continuous evolution of the semiconductor market necessitates ever-increasing improvements in DUV light source uptime as defined in the SEMI E10 standard. Cymer is developing technologies to exceed current and projected light source availability requirements via significant reduction in light source downtime. As an example, consider discharge chamber gas management functions which comprise a sizable portion of DUV light source downtime. Cymer's recent introduction of Gas Lifetime Extension (GLXTM) as a productivity improvement technology for its DUV lithography light sources has demonstrated noteworthy reduction in downtime. This has been achieved by reducing the frequency of full gas replenishment events from once per 100 million pulses to as low as once per 2 billion pulses. Cymer has continued to develop relevant technologies that target further reduction in downtime associated with light source gas management functions. Cymer's current subject is the development of technologies to reduce downtime associated with gas state optimization (e.g. total chamber gas pressure) and gas life duration. Current gas state optimization involves execution of a manual procedure at regular intervals throughout the lifetime of light source core components. Cymer aims to introduce a product enhancement - iGLXTM - that eliminates the need for the manual procedure and, further, achieves 4 billion pulse gas lives. Projections of uptime on DUV light sources indicate that downtime associated with gas management will be reduced by 70% when compared with GLX2. In addition to reducing downtime, iGLX reduces DUV light source cost of operation by constraining gas usage. Usage of fluorine rich Halogen gas mix has been reduced by 20% over GLX2.
Design and evaluation of excitation light source device for fluorescence endoscope
NASA Astrophysics Data System (ADS)
Lim, Hyun Soo
2009-06-01
This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.
Modeling of an Adjustable Beam Solid State Light Project
NASA Technical Reports Server (NTRS)
Clark, Toni
2015-01-01
This proposal is for the development of a computational model of a prototype variable beam light source using optical modeling software, Zemax Optics Studio. The variable beam light source would be designed to generate flood, spot, and directional beam patterns, while maintaining the same average power usage. The optical model would demonstrate the possibility of such a light source and its ability to address several issues: commonality of design, human task variability, and light source design process improvements. An adaptive lighting solution that utilizes the same electronics footprint and power constraints while addressing variability of lighting needed for the range of exploration tasks can save costs and allow for the development of common avionics for lighting controls.
An experiment on the color rendering of different light sources
NASA Astrophysics Data System (ADS)
Fumagalli, Simonetta; Bonanomi, Cristian; Rizzi, Alessandro
2013-02-01
The color rendering index (CRI) of a light source attempts to measure how much the color appearance of objects is preserved when they are illuminated by the given light source. This problem is of great importance for various industrial and scientific fields, such as lighting architecture, design, ergonomics, etc. Usually a light source is specified through the Correlated Color Temperature or CCT. However two (or more) light sources with the same CCT but different spectral power distribution can exist. Therefore color samples viewed under two light sources with equal CCTs can appear different. Hence, the need for a method to assess the quality of a given illuminant in relation to color. Recently CRI has had a renewed interest because of the new LED-based lighting systems. They usually have a color rendering index rather low, but good preservation of color appearance and a pleasant visual appearance (visual appeal). Various attempts to develop a new color rendering index have been done so far, but still research is working for a better one. This article describes an experiment performed by human observers concerning the appearance preservation of color under some light sources, comparing it with a range of available color rendering indices.
EGR distribution and fluctuation probe based on CO.sub.2 measurements
Parks, II, James E; Partridge, Jr., William P; Yoo, Ji Hyung
2015-04-07
A diagnostic system having a single-port EGR probe and a method for using the same. The system includes a light source, an EGR probe, a detector and a processor. The light source may provide a combined light beam composed of light from a mid-infrared signal source and a mid-infrared reference source. The signal source may be centered at 4.2 .mu.m and the reference source may be centered at 3.8 .mu.m. The EGR probe may be a single-port probe with internal optics and a sampling chamber with two flow cells arranged along the light path in series. The optics may include a lens for focusing the light beam and a mirror for reflecting the light beam received from a pitch optical cable to a catch optical cable. The signal and reference sources are modulated at different frequencies, thereby allowing them to be separated and the signal normalized by the processor.
Synchrotron Light Sources in Developing Countries
NASA Astrophysics Data System (ADS)
Winick, Herman; Pianetta, Piero
The more than 50 light sources in operation include facilities in Brazil, Korea, and Taiwan which started in the 1980's when they were developing countries. They came on line in the 1990's and have since trained hundreds of graduate students. They have attracted mid-career diaspora scientists to return. Growing user communities have demanded more advanced facilities, leading to higher performance new light sources that are now coming into operation. Light sources in the developing world now include the following: ∖textbf{SESAME}in the Middle East which is scheduled to start research in 2017 (∖underline {www.sesame.org}); ∖textbf{The African Light Source}, in the planning stage (∖underline {www.safricanlightsource.org}); and ∖textbf{The Mexican Light Source}, in the planning stage (∖underline {http://www.aps.org/units/fip/newsletters/201509/mexico.cfm}). See: http://wpj.sagepub.com/content/32/4/92.full.pdf +html; http://www.lightsources.org/press-release/2015/11/20/grenoble-resolutions-mark-historical-step-towards-african-light-source..
Reduction of background clutter in structured lighting systems
Carlson, Jeffrey J.; Giles, Michael K.; Padilla, Denise D.; Davidson, Jr., Patrick A.; Novick, David K.; Wilson, Christopher W.
2010-06-22
Methods for segmenting the reflected light of an illumination source having a characteristic wavelength from background illumination (i.e. clutter) in structured lighting systems can comprise pulsing the light source used to illuminate a scene, pulsing the light source synchronously with the opening of a shutter in an imaging device, estimating the contribution of background clutter by interpolation of images of the scene collected at multiple spectral bands not including the characteristic wavelength and subtracting the estimated background contribution from an image of the scene comprising the wavelength of the light source and, placing a polarizing filter between the imaging device and the scene, where the illumination source can be polarized in the same orientation as the polarizing filter. Apparatus for segmenting the light of an illumination source from background illumination can comprise an illuminator, an image receiver for receiving images of multiple spectral bands, a processor for calculations and interpolations, and a polarizing filter.
ERIC Educational Resources Information Center
Kesonen, Mikko Henri Petteri; Asikainen, Mervi Anita; Hirvonen, Pekka Emil
2017-01-01
In the present article, the context-dependency of student reasoning is studied in a context of optics. We investigated introductory students' explanations about the behavior of light when different light sources, namely a small light bulb and a laser, were used in otherwise identical task assignments. The data was gathered with the aid of pretest…
Microelectromechanical Systems (MEMS) Broadband Light Source Developed
NASA Technical Reports Server (NTRS)
Tuma, Margaret L.
2003-01-01
A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip-based light source has the potential for monolithic fabrication with on-chip drive electronics. Other uses for these light sources are in systems for vehicle navigation, remote sensing applications such as monitoring bridges for stress, calibration sources for spectrometers, light sources for space sensors, display lighting, addressable arrays, and industrial plant monitoring. Two methods for filament fabrication are being developed: wet-chemical etching and laser ablation. Both yield a 25-mm-thick tungsten spiral filament. The proof-of-concept filament shown was fabricated with the wet etch method. Then it was tested by heating it in a vacuum chamber using about 1.25 W of electrical power; it generated bright, blackbody radiation at approximately 2650 K. The filament was packaged in Glenn's clean-room facilities. This design uses three chips vacuum-sealed with glass tape. The bottom chip consists of a reflective film deposited on silicon, the middle chip contains a tungsten filament bonded to silicon, and the top layer is a transparent window. Lifetime testing on the package will begin shortly. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 mm.
Advanced Photon Source Upgrade Project - Materials
Gibbson, Murray
2018-03-02
An upgrade to Advanced Photon Source announced by DOE - http://go.usa.gov/ivZ -- will help scientists break through bottlenecks in materials design in order to develop materials with desirable functions.
A compact high brightness laser synchrotron light source for medical applications
NASA Astrophysics Data System (ADS)
Nakajima, Kazuhisa
1999-07-01
The present high-brightness hard X-ray sources have been developed as third generation synchrotron light sources based on large high energy electron storage rings and magnetic undulators. Recently availability of compact terawatt lasers arouses a great interest in the use of lasers as undulators. The laser undulator concept makes it possible to construct an attractive compact synchrotron radiation source which has been proposed as a laser synchrotron light source. This paper proposes a compact laser synchrotron light source for mediacal applications, such as an intravenous coronary angiography and microbeam therapy.
NASA Technical Reports Server (NTRS)
Kersten, Ralf T. (Editor)
1990-01-01
Recent advances in fiber-optic sensor (FOS) technology are examined in reviews and reports. Sections are devoted to components for FOSs, special fibers for FOSs, interferometry, FOS applications, and sensing principles and influence. Particular attention is given to solder glass sealing technology for FOS packaging, the design of optical-fiber current sensors, pressure and temperature effects on beat length in highly birefringent optical fibers, a pressure FOS based on vibrating-quartz-crystal technology, remote sensing of flammable gases using a fluoride-fiber evanescent probe, a displacement sensor with electronically scanned white-light interferometer, the use of multimode laser diodes in low-coherence coupled-cavity interferometry, electronic speckle interferometry compensated for environmentally induced phase noise, a dual-resolution noncontact vibration and displacement sensor based on a two-wavelength source, and fiber optics in composite materials.
NASA Astrophysics Data System (ADS)
Laskar, S.; Bordoloi, S.
2016-01-01
This paper presents an instrumentation system to measure the degradation in lubricating oil using a bare, tapered and bent multi-mode optical fiber (BTBMOF) sensor probe and a temperature probe. The sensor system consists of (i) a bare, tapered and bent multi-mode optical fiber (BTBMOF) as optical sensor along with a laser source and a LDR (Light Dependent Resistor) as detector (ii) a temperature sensor (iii) a ATmega microcontroller based data acquisition system and (iv) a trained ANN for processing and calibration. The BTBMOF sensor and the temperature sensor are used to provide the measure of refractive index (RI) and the temperature of a lubricating oil sample. A microcontroller based instrumentation system with trained ANN algorithm has been developed to determine the degradation of the lubricating oil sample by sampling the readings of the optical fiber sensor, and the temperature sensor.
Broad-band properties of the CfA Seyfert galaxies. III - Ultraviolet variability
NASA Technical Reports Server (NTRS)
Edelson, R. A.; Pike, G. F.; Krolik, J. H.
1990-01-01
A total of 657 archived IUE spectra are used to study the UV variability properties of six members of the CfA Seyfert I galaxy sample. All show strong evidence for continuum and line variations and a tendency for less luminous objects to be more strongly variable. Most objects show a clear correlation at zero lag between UV spectral index and luminosity, evidence that the variable component is an accretion disk around a black hole which is systematically smaller in less luminous sources. No correlation is seen between the continuum luminosity and equivalent width of the C IV, Mg II, and semiforbidden C III emission lines when the entire sample is examined, but a clear anticorrelation is present when only repeated observations of individual objects are considered. This is due to a combination of light-travel time effects in the broad-line region and the nonlinear responses of lines to continuum fluctuations.
Effect of N, S Co-doped TiO2 concentration on photocatalytic degradation of phenol
NASA Astrophysics Data System (ADS)
Yunus, Nur Najwa; Hamzah, Fazlena; So'aib, Mohamad Sufian; Krishnan, Jagannathan
2017-12-01
The effect of N, S Co-doped TiO2 concentration on photocatalytic degradation of phenol was investigated. The photocatalyst were prepared using sol-gel method with different concentration of dopant ranging from 0.5% to 1.0%. The precursor of titania was Titanium (IV) isopropoxide (TTIP) while the sources of nitrogen and sulfur were ammonium nitrate and thiourea respectively. The precursors were mixed to obtain a gel. The gel was dried, ground and calcined at 600 °C. The characterization of the photocatalyst using XRD showed the presence of anatase phase only and dopant concentration of 1.0% had the smallest size of crystallite which is 24 nm. The performance of the photocatalyst was tested under visible light for five hours of irradiation time. The highest degradation efficiency of phenol was at 81.8% by dopant concentration of 1.0%.
The Use of Light-Emitting Diodes (LEDs) as Green and Red/Far-Red Light Sources in Plant Physiology.
ERIC Educational Resources Information Center
Jackson, David L.; And Others
1985-01-01
The use of green, red, and far-red light-emitting diodes (LEDs) as light sources for plant physiological studies is outlined and evaluated. Indicates that LED lamps have the advantage over conventional light sources in that they are lightweight, low-cost, portable, easily constructed, and do not require color filters. (Author/DH)
First account of apochlorotic diatoms from intertidal sand of a south Florida beach
NASA Astrophysics Data System (ADS)
Blackburn, Michele V.; Hannah, Fiona; Rogerson, Andrew
2009-10-01
During the period January to December 2004, monthly intertidal sand samples were collected from John U. Lloyd State Park beach, Florida. This study is the first to report on spatial and temporal distributions of heterotrophic (apochlorotic) diatoms in a sub-tropical beach, or indeed any sandy beach. Two non-pigmented, apochlorotic diatom morphotypes (strains III and IV) were consistently isolated from two intertidal beach sites and neither conformed to the morphologies of described species. Apochlorotic diatoms were found throughout the year and formed significant peaks in April, attaining total diatom counts of 71.1 and 94.9 cells g -1 wet sand, for the upper tidal zone and lower tidal zone, respectively. Valve morphology is described in detail for the two diatom morphotypes isolated from the beach sites (strains III and IV). Growth responses to changes in salinity (reflecting those of the intertidal zone) were examined in the laboratory for these diatoms. Both morphotypes were euryhaline, tolerating salinities between 10 and 50, and maximum growth rates were achieved at salinities between 20 and 40. Diatoms grew equally well whether grown in the light or the dark and showed no evidence of pigments when viewed by epifluorescence microscopy. The ability of diatoms to burrow into agar and carrageenan at different concentrations was tested. Both morphotypes were observed to develop burrows through non-nutrient agar up to twice the standard concentration (30 g agar l -1). The ease with which these heterotrophic diatoms formed burrows suggests that they were digesting these complex carbohydrates (i.e. phycocolloids) as a nutrient source. Strain IV, however, failed to burrow in a different phycocolloid, carrageenan. Similar degradative actions in the field might have implications for the breakdown of recalcitrant materials or allow diatoms to effectively compete with bacteria for carbon and nutrients.
NASA Technical Reports Server (NTRS)
1993-01-01
Research on food growth for long duration spacecraft has resulted in a light source for growing plants indoors known as Qbeam, a solid state light source consisting of a control unit and lamp. The light source, manufactured by Quantum Devices, Inc., is not very hot, although it generates high intensity radiation. When Ron Ignatius, an industrial partner of WCSAR, realized that terrestrial plant research lighting was not energy efficient enough for space use, he and WCSAR began to experiment with light emitting diodes. A line of LED products was developed, and QDI was formed to market the technology. An LED-based cancer treatment device is currently under development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riza, Nabeel Agha; Perez, Frank
A remote temperature sensing system includes a light source selectively producing light at two different wavelengths and a sensor device having an optical path length that varies as a function of temperature. The sensor receives light emitted by the light source and redirects the light along the optical path length. The system also includes a detector receiving redirected light from the sensor device and generating respective signals indicative of respective intensities of received redirected light corresponding to respective wavelengths of light emitted by the light source. The system also includes a processor processing the signals generated by the detector tomore » calculate a temperature of the device.« less
Illumination control apparatus for compensating solar light
NASA Technical Reports Server (NTRS)
Owens, L. J. (Inventor)
1978-01-01
An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.
Azorín, Erika; Solano-Agama, Carmen; Mendoza-Garrido, M Eugenia
2012-12-15
The adaptation of GH(3) cells to different microenvironments is a consequence of a partial compromise with the tumor phenotype. A collagen type IV enriched microenvironment favors an invasive phenotype and increases the substrate adhesion capacity, whereas it decreases the phosphorylation of the regulatory myosin light chain and the aggregation capacity. In contrast, the higher internal tension and increased aggregation capacity induced by collagen type I/III are factors that reduce the invasion rate. Our results show, for the first time, the importance of collagen subtypes in determining the migratory strategy: collagen I/III favors mesenchymal-like motility, whereas collagen type IV induces an ameboid-type displacement. The reciprocal modulation of the myosin light chain kinase and the Rho-kinase determines the invasive capacity through changes in tissue cohesion, extracellular matrix affinity, regulatory myosin light chain phosphorylation and spatial distribution. The collagen subtype determines which of the mechano-transduction signaling pathways will regulate the tensional homeostasis and affect the invasion ability as well as the preferred migration strategy of the cells. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shelton, Robin L.
2018-06-01
High velocity clouds (HVCs) and turbulent mixing layers (TMLs) emit light across a wide range of wavelengths. In order to aid in the detection of their ultraviolet emission, we predict the UV emission line intensities emitted by C II, C III, C IV, N II, N III, N IV, N V, O III, O IV, O V, O VI, Si II, Si III, and Si IV in a variety of simulated HVCs and TMLs. These predictions are based on detailed hydrodynamic simulations made with the FLASH code and employing non-equilibrium ionization calculations for carbon, nitrogen, oxygen, and silicon. The results are compared with FUSE and SPEAR/FIMS observations and with predictions from other models of hot/cool interfaces. We also present methods for scaling the results so that they can be applied to more or less dense environments.
Emission lines in the long period Cepheid l Carinae
NASA Technical Reports Server (NTRS)
Boehm-Vitense, Erika; Love, Stanley G.
1991-01-01
For the Cepheid (l) Carinae with a pulsation period of 35.5 days we have studied the emission line fluxes as a function of pulsational phase in order to find out whether we see chromosphere and transition layer emission or whether we see emission due to an outward moving shock. All emission lines show a steep increase in flux shortly before maximum light suggestive of a shock moving through the surface layers. The large ratio of the C IV to C II line fluxes shows that these are not transition layer lines. During maximum light the large ratio of the C IV to C II line fluxes also suggests that we see emission from a shock with velocities greater than 100 km/sec such that C IV emission can be excited. With such velocities mass outflow appears possible. The variations seen in the Mg II line profiles show that there is an internal absorption over a broad velocity band independent of the pulsational phase. We attribute this absorption to a circumstellar 'shell'. This 'shell' appears to be seen also as spatially extended emission in the O I line at 1300 angstrom, which is probably excited by resonance with Ly beta.
NASA Astrophysics Data System (ADS)
Tobaldi, D. M.; Pullar, R. C.; Gualtieri, A. F.; Otero-Irurueta, G.; Singh, M. K.; Seabra, M. P.; Labrincha, J. A.
2015-11-01
Titanium dioxide (TiO2) is a popular photocatalyst used for many environmental and anti-pollution applications, but it normally operates under UV light, exploiting ∼5% of the solar spectrum. Nitrification of titania to form N-doped TiO2 has been explored as a way to increase its photocatalytic activity under visible light, and anionic doping is a promising method to enable TiO2 to harvest visible-light by changing its photo-absorption properties. In this paper, we explore the insertion of nitrogen into the TiO2 lattice using our green sol-gel nanosynthesis method, used to create 10 nm TiO2 NPs. Two parallel routes were studied to produce nitrogen-modified TiO2 nanoparticles (NPs), using HNO3+NH3 (acid-precipitated base-peptised) and NH4OH (totally base catalysed) as nitrogen sources. These NPs were thermally treated between 450 and 800 °C. Their true phase composition (crystalline and amorphous phases), as well as their micro-/nanostructure (crystalline domain shape, size and size distribution, edge and screw dislocation density) was fully characterised through advanced X-ray methods (Rietveld-reference intensity ratio, RIR, and whole powder pattern modelling, WPPM). As pollutants, nitrogen oxides (NOx) are of particular concern for human health, so the photocatalytic activity of the NPs was assessed by monitoring NOx abatement, using both solar and white-light (indoor artificial lighting), simulating outdoor and indoor environments, respectively. Results showed that the onset of the anatase-to-rutile phase transformation (ART) occurred at temperatures above 450 °C, and NPs heated to 450 °C possessed excellent photocatalytic activity (PCA) under visible white-light (indoor artificial lighting), with a PCA double than that of the standard P25 TiO2 NPs. However, higher thermal treatment temperatures were found to be detrimental for visible-light photocatalytic activity, due to the effects of four simultaneous occurrences: (i) loss of OH groups and water adsorbed on the photocatalyst surface; (ii) growth of crystalline domain sizes with decrease in specific surface area; (iii) onset and progress of the ART; (iv) the increasing instability of the nitrogen in the titania lattice.
A numerical experiment on light pollution from distant sources
NASA Astrophysics Data System (ADS)
Kocifaj, M.
2011-08-01
To predict the light pollution of the night-time sky realistically over any location or measuring point on the ground presents quite a difficult calculation task. Light pollution of the local atmosphere is caused by stray light, light loss or reflection of artificially illuminated ground objects or surfaces such as streets, advertisement boards or building interiors. Thus it depends on the size, shape, spatial distribution, radiative pattern and spectral characteristics of many neighbouring light sources. The actual state of the atmospheric environment and the orography of the surrounding terrain are also relevant. All of these factors together influence the spectral sky radiance/luminance in a complex manner. Knowledge of the directional behaviour of light pollution is especially important for the correct interpretation of astronomical observations. From a mathematical point of view, the light noise or veil luminance of a specific sky element is given by a superposition of scattered light beams. Theoretical models that simulate light pollution typically take into account all ground-based light sources, thus imposing great requirements on CPU and MEM. As shown in this paper, a contribution of distant sources to the light pollution might be essential under specific conditions of low turbidity and/or Garstang-like radiative patterns. To evaluate the convergence of the theoretical model, numerical experiments are made for different light sources, spectral bands and atmospheric conditions. It is shown that in the worst case the integration limit is approximately 100 km, but it can be significantly shortened for light sources with cosine-like radiative patterns.
Frank, Alan M.; Edwards, William R.
1983-01-01
A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.
Collimating lens for light-emitting-diode light source based on non-imaging optics.
Wang, Guangzhen; Wang, Lili; Li, Fuli; Zhang, Gongjian
2012-04-10
A collimating lens for a light-emitting-diode (LED) light source is an essential device widely used in lighting engineering. Lens surfaces are calculated by geometrical optics and nonimaging optics. This design progress does not rely on any software optimization and any complex iterative process. This method can be used for any type of light source not only Lambertian. The theoretical model is based on point source. But the practical LED source has a certain size. So in the simulation, an LED chip whose size is 1 mm*1 mm is used to verify the feasibility of the model. The mean results show that the lenses have a very compact structure and good collimating performance. Efficiency is defined as the ratio of the flux in the illuminated plane to the flux from LED source without considering the lens material transmission. Just investigating the loss in the designed lens surfaces, the two types of lenses have high efficiencies of more than 90% and 99%, respectively. Most lighting area (possessing 80% flux) radii are no more than 5 m when the illuminated plane is 200 m away from the light source.
Evaluation of OLED and edge-lit LED lighting panels
NASA Astrophysics Data System (ADS)
Mou, Xi; Narendran, Nadarajah; Zhu, Yiting; Freyssinier, Jean Paul
2016-09-01
Solid-state lighting (SSL) offers a new technology platform for lighting designers and end-users to illuminate spaces with low energy demand. Two types of SSL sources include organic light-emitting diodes (OLEDs) and light-emitting diodes (LEDs). OLED is an area light source, and its primary competing technology is the edge-lit LED panel. Generally, both of these technologies are considered similar in shape and appearance, but there is little understanding of how people perceive discomfort glare from large area light sources. The objective of this study was to evaluate discomfort glare for the two lighting technologies under similar operating conditions by gathering observers' reactions. The human factors study results showed no statistically significant difference in human response to discomfort glare between OLED and edge-lit LED panels when the two light sources produced the same lighting stimulus. This means both technologies appeared equally glary beyond a certain luminance.
Discrepancy Score Reliabilities in the WAIS-IV Standardization Sample
ERIC Educational Resources Information Center
Glass, Laura A.; Ryan, Joseph J.; Charter, Richard A.
2010-01-01
In the present investigation, the authors provide internal consistency reliabilities for Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) subtest and Index discrepancy scores using the standardization sample as the data source. Reliabilities ranged from 0.55 to 0.88 for subtest discrepancy scores and 0.80 to 0.91 for Index discrepancy…
NASA Astrophysics Data System (ADS)
Neidhardt, Alexander; Collioud, Arnaud
2014-12-01
A central VLBI network status monitoring can be realized by using online status information about current VLBI sessions, real-time, and status data directly from each radio telescope. Such monitoring helps to organize sessions or to get immediate feedback from the active telescopes. Therefore the remote control software for VLBI radio telescopes ``e-RemoteCtrl'' (http://www.econtrol-software.de), which enables remote access as extension to the NASA Field System, realizes real-time data streams to dedicated data centers. The software has direct access to the status information about the current observation (e.g., schedule, scan, source) and the telescope (e.g., current state, temperature, pressure) in real-time. This information are directly sent to ``IVS Live''. ``IVS Live'' (http://ivslive.obs.u-bordeaux1.fr/) is a Web tool that can be used to follow the observing sessions, organized by the International VLBI Service for Geodesy and Astrometry (IVS), navigate through past or upcoming sessions, or search and display specific information about sessions, sources (like VLBI images), and stations, by using an Internet browser.
Optical nulling apparatus and method for testing an optical surface
NASA Technical Reports Server (NTRS)
Olczak, Eugene (Inventor); Hannon, John J. (Inventor); Dey, Thomas W. (Inventor); Jensen, Arthur E. (Inventor)
2008-01-01
An optical nulling apparatus for testing an optical surface includes an aspheric mirror having a reflecting surface for imaging light near or onto the optical surface under test, where the aspheric mirror is configured to reduce spherical aberration of the optical surface under test. The apparatus includes a light source for emitting light toward the aspheric mirror, the light source longitudinally aligned with the aspheric mirror and the optical surface under test. The aspheric mirror is disposed between the light source and the optical surface under test, and the emitted light is reflected off the reflecting surface of the aspheric mirror and imaged near or onto the optical surface under test. An optical measuring device is disposed between the light source and the aspheric mirror, where light reflected from the optical surface under test enters the optical measuring device. An imaging mirror is disposed longitudinally between the light source and the aspheric mirror, and the imaging mirror is configured to again reflect light, which is first reflected from the reflecting surface of the aspheric mirror, onto the optical surface under test.
Mancuso, J. Jacob; Halaney, David L.; Elahi, Sahar; Ho, Derek; Wang, Tianyi; Ouyang, Yongjian; Dijkstra, Jouke; Milner, Thomas E.; Feldman, Marc D.
2014-01-01
Abstract. We sought to elucidate the mechanisms underlying two common intravascular optical coherence tomography (IV-OCT) artifacts that occur when imaging metallic stents: “merry-go-rounding” (MGR), which is an increase in strut arc length (SAL), and “blooming,” which is an increase in the strut reflection thickness (blooming thickness). Due to uncontrollable variables that occur in vivo, we performed an in vitro assessment of MGR and blooming in stented vessel phantoms. Using Xience V and Driver stents, we examined the effects of catheter offset, intimal strut coverage, and residual blood on SAL and blooming thickness in IV-OCT images. Catheter offset and strut coverage both caused minor MGR, while the greatest MGR effect resulted from light scattering by residual blood in the vessel lumen, with 1% hematocrit (Hct) causing a more than fourfold increase in SAL compared with saline (p<0.001). Residual blood also resulted in blooming, with blooming thickness more than doubling when imaged in 0.5% Hct compared with saline (p<0.001). We demonstrate that a previously undescribed mechanism, light scattering by residual blood in the imaging field, is the predominant cause of MGR. Light scattering also results in blooming, and a newly described artifact, three-dimensional-MGR, which results in “ghost struts” in B-scans. PMID:25545341
Red Light Emitting Schottky Diodes on p-TYPE GaN/AlN/Si(111) Substrate
NASA Astrophysics Data System (ADS)
Chuah, L. S.; Hassan, Z.; Abu Hassan, H.
High quality GaN layers doped with Mg were grown on Si(111) substrates using high temperature AlN as buffer layer by radio-frequency molecular beam epitaxy. From the Hall measurements, fairly uniform high hole concentration as high as (4-5) × 1020 cm-3 throughout the GaN was achieved. The fabrication of the device is very simple. Nickel ohmic contacts and Schottky contacts using indium were fabricated on Mg-doped p-GaN films. The light emission has been obtained from these thin film electroluminescent devices. Thin film electroluminescent devices were operated under direct current bias. Schottky and ohmic contacts used as cathode and anode were employed in these investigations. Alternatively, two Schottky contacts could be probed as cathode and anode. Thin film electroluminescent devices were able to emit light. However, electrical and optical differences could be observed from the two different probing methods. The red light color could be observed when the potential between the electrodes was increased gradually under forward bias of 8 V at room temperature. Electrical properties of these thin film electroluminescent devices were characterized by current-voltage (I-V) system, the heights of barriers determined from the I-V measurements were found to be related to the electroluminescence.
NASA Technical Reports Server (NTRS)
Berghea, C. T.; Dudik, R. P.; Weaver, K. A.; Kallman, T. R.
2009-01-01
This is the second of two papers examining Spitzer Infrared Spectrograph (IRS) observations of the ultraluminous X-ray source (ULX) in Holmberg II. Here we perform detailed photoionization modeling of they infrared lines. Our analysis suggests that the luminosity and morphology of the [O IV] 25.89 micron emission line is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is matter-bounded both in the line of sight direction and to the east, and probably radiation-bounded to the west. A bolometric luminosity in excess of 1040 erg per second would be needed to produce the measured [O IV] flux. We use modeling and previously published studies to conclude that shacks likely contribute very little, if at all, to the high excitation line fluxes observed in the Holmberg II ULX. Additionally, we find that the spectral type of the companion star has a surprisingly strong effect on they predicted strength of the [O IV] emission. This finding could explain the origin of [O IV] hi some starburst systems containing black hole binaries.
NASA Technical Reports Server (NTRS)
Berghea, C. T.; Dudik, R. P.; Weaver, K. A.; Kallman, T. R.
2009-01-01
This is the second of two papers examining Spitzer Infrared Spectrograph (IRS) observations of the ultraluminous X-ray source (ULX) in Holmberg II. Here we perform detailed photoionization modeling of the infrared lines. Our analysis suggests that the luminosity and morphology of the [O IV] 25.89 micron emission line is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is matter-bounded both in the line of sight direction and to the east, and probably radiation-bounded to the west. A bolometric luminosity in excess of 10(exp 40) erg/s would be needed to produce the measured [O IV] flux. We use modeling and previously published studies to conclude that shocks likely contribute very little, if at all, to the high-excitation line fluxes observed in the Holmberg II ULX. Additionally, we find that the spectral type of the companion star has a surprisingly strong effect on the predicted strength of the [O IV] emission. This finding could explain the origin of [O IV] in some starburst systems containing black hole binaries.
Flicker Vision of Selected Light Sources
NASA Astrophysics Data System (ADS)
Otomański, Przemysław; Wiczyński, Grzegorz; Zając, Bartosz
2017-10-01
The results of the laboratory research concerning a dependence of flicker vision on voltage fluctuations are presented in the paper. The research was realized on a designed measuring stand, which included an examined light source, a voltage generator with amplitude modulation supplying the light source and a positioning system of the observer with respect to the observed surface. In this research, the following light sources were used: one incandescent lamp and four LED luminaires by different producers. The research results formulate a conclusion concerning the description of the influence of voltage fluctuations on flicker viewing for selected light sources. The research results indicate that LED luminaires are less susceptible to voltage fluctuations than incandescent bulbs and that flicker vision strongly depends on the type of LED source.
Monolithic LED arrays, next generation smart lighting sources
NASA Astrophysics Data System (ADS)
Lagrange, Alexandre; Bono, Hubert; Templier, François
2016-03-01
LED have become the main light sources of the future as they open the path for intelligent use of light in time, intensity and color. In many usages, strong energy economy is done by adjusting these properties. The smart lighting has three dimensions, energy efficiency brought by GaN blue emitting LEDs, integration of electronics, sensors, microprocessors in the lighting system and development of new functionalities and services provided by the light. Monolithic LED arrays allow two major innovations, the spatial control of light emission and the adjustment of the electrical properties of the source.
High temperature, minimally invasive optical sensing modules
Riza, Nabeel Agha [Oviedo, FL; Perez, Frank [Tujunga, CA
2008-02-05
A remote temperature sensing system includes a light source selectively producing light at two different wavelengths and a sensor device having an optical path length that varies as a function of temperature. The sensor receives light emitted by the light source and redirects the light along the optical path length. The system also includes a detector receiving redirected light from the sensor device and generating respective signals indicative of respective intensities of received redirected light corresponding to respective wavelengths of light emitted by the light source. The system also includes a processor processing the signals generated by the detector to calculate a temperature of the device.
Side-emitting illuminators using LED sources
NASA Astrophysics Data System (ADS)
Zhao, Feng; Van Derlofske, John F.
2003-11-01
This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.
Heussler, Carina D; Walter, Andreas; Oberkofler, Hannes; Insam, Heribert; Arthofer, Wolfgang; Schlick-Steiner, Birgit C; Steiner, Florian M
2018-01-01
Hermetia illucens (L.), the Black Soldier Fly, has received increased scientific attention for its potential in circular waste management where larvae can serve as feedstuff for livestock and for biodiesel production. The flies occur naturally in (sub)-tropical and warm-temperate climates, and their mating depends on space and sunlight. Small-scale indoor rearing of Black Soldier Flies has been challenging because they react sensitive to artificial light sources and cage sizes, but recent studies have shown that small-scale rearing under artificial light is feasible. Here, we test the influence of three artificial light sources (light-emitting diodes, fluorescent lamps, and halogen lamps) on small-scale indoor rearing. Three experiments were conducted to compare oviposition traits (pre-oviposition period, total oviposition-period, and egg mass per female) and half-life among the three light sources. Oviposition did not differ among the three light sources, but male and female half-life did. Based on the performance of the light-emitting diodes and their outstanding energy efficiency, we recommend this light source for small-scale indoor rearing of Black Soldier Flies.
NASA Astrophysics Data System (ADS)
Taudt, Ch.; Baselt, T.; Nelsen, B.; Assmann, H.; Greiner, A.; Koch, E.; Hartmann, P.
2017-06-01
Within this work an alternative approach to precision surface profilometry based on a low-coherence interferometer is presented. Special emphasis is placed on the characterization of edge effects, which influence the measurement result on sharp edges and steep slopes. In contrast to other works, this examination focuses on the comparison of very broadband light sources such as a supercontinuum white-light source (SC; 380 - 1100 nm) and a laser-driven plasma light source (LDP; 200 - 1100 nm) and their influence on the formation of these effects. The interferometer is equipped with one of these broadband light sources and a defined dispersion over a given spectral range. The spectral width of the light sources in combination with the dispersive element defines the possible measurement range and resolution. Instead of detecting the signals only in a one-dimensional manner, an imaging spectrometer on the basis of a high resolution CMOS-camera is set-up. Through the introduction of a defined dispersion, a controlled phase variation in the spectral domain is created. This phase variation is dependent on the optical path difference between both arms and can therefore be used as a measure for the height of a structure which is present in one arm. The results of measurements on a 100 nm height standard with both selected light sources have been compared. Under consideration of the coherence length of both light sources of 1.58 μm for the SC source and 1.81 m for the LDP source differences could be recorded. Especially at sharp edges, the LDP light source could record height changes with slopes twice as steep as the SC source. Furthermore, it became obvious, that measurements with the SC source tend to show edge effects like batwings due to diffraction. Additional effects on the measured roughness and the flatness of the profile were investigated and discussed.
GLOBAL ENERGETICS OF SOLAR FLARES. IV. CORONAL MASS EJECTION ENERGETICS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aschwanden, Markus J., E-mail: aschwanden@lmsal.com
2016-11-01
This study entails the fourth part of a global flare energetics project, in which the mass m {sub cme}, kinetic energy E {sub kin}, and the gravitational potential energy E {sub grav} of coronal mass ejections (CMEs) is measured in 399 M and X-class flare events observed during the first 3.5 years of the Solar Dynamics Observatory (SDO) mission, using a new method based on the EUV dimming effect. EUV dimming is modeled in terms of a radial adiabatic expansion process, which is fitted to the observed evolution of the total emission measure of the CME source region. The modelmore » derives the evolution of the mean electron density, the emission measure, the bulk plasma expansion velocity, the mass, and the energy in the CME source region. The EUV dimming method is truly complementary to the Thomson scattering method in white light, which probes the CME evolution in the heliosphere at r ≳ 2 R {sub ⊙}, while the EUV dimming method tracks the CME launch in the corona. We compare the CME parameters obtained in white light with the LASCO/C2 coronagraph with those obtained from EUV dimming with the Atmospheric Imaging Assembly onboard the SDO for all identical events in both data sets. We investigate correlations between CME parameters, the relative timing with flare parameters, frequency occurrence distributions, and the energy partition between magnetic, thermal, nonthermal, and CME energies. CME energies are found to be systematically lower than the dissipated magnetic energies, which is consistent with a magnetic origin of CMEs.« less
NASA Astrophysics Data System (ADS)
Zhou, Wenhan; Guo, Shiying; Liu, Xuhai; Cai, Bo; Song, Xiufeng; Zhu, Zhen; Zhang, Shengli
2018-01-01
We propose a family of hydrogenated- and halogenated-SbIV (SbIVX-2) materials that simultaneously have two-dimensional (2D) structures, high stability and appealing electronic properties. Based on first-principles total-energy and vibrational-spectra calculations, SbIVX-2 monolayers are found both thermally and dynamically stable. Varying IV and X elements can rationally tune the electronic properties of SbIVX-2 monolayers, effectively modulating the band gap from 0 to 3.42 eV. Regarding such superior stability and broad band-gap range, SbIVX-2 monolayers are expected to be synthesized in experiments and taken as promising candidates for low-dimensional electronic and optoelectronic devices, such as blue-to-ultraviolet light-emitting diodes (LED) and photodetectors.
Frank, A.M.; Edwards, W.R.
1983-10-11
A long-lifetime light source with sufficiently low intensity to be used for reading a map or other writing at nighttime, while not obscuring the user's normal night vision is disclosed. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode. 1 fig.
Frank, A.M.; Edwards, W.R.
1982-03-23
A long-lifetime light source is discussed with sufficiently low intensity to be used for reading a map or other writing at nightime, while not obscuring the user's normal night vision. This light source includes a diode electrically connected in series with a small power source and a lens properly positioned to focus at least a portion of the light produced by the diode.
... can be exacerbated by light sources such as computer screens or fluorescent lights. Use a flicker-free ... cubicle shield Allow frequent breaks from tasks involving computer Provide alternative light sources: Replace fluorescent lights with ...
Internal heat gain from different light sources in the building lighting systems
NASA Astrophysics Data System (ADS)
Suszanowicz, Dariusz
2017-10-01
EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output) were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.
Modelling of a laser-pumped light source for endoscopic surgery
NASA Astrophysics Data System (ADS)
Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.
2008-09-01
A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.
Epidemiology of melasma in Brazilian patients: a multicenter study.
Hexsel, Doris; Lacerda, Davi A; Cavalcante, Andrea S; Machado Filho, Carlos A S; Kalil, Célia Luiza P V; Ayres, Eloísa L; Azulay-Abulafia, Luna; Weber, Magda B; Serra, Marcio S; Lopes, Nádya F P; Cestari, Tania F
2014-04-01
Melasma is an acquired, irregularly patterned, light to dark-brown hypermelanosis, with symmetric distribution mostly over the face. The aim of this study was to evaluate clinical characteristics and factors related to melasma in Brazilian patients. This was a cross-sectional, multicenter study performed in Brazil. Investigators examined and questioned 953 patients over 18 years of age on clinical characteristics and other factors related to their melasma. Melasma was more prevalent in women (97.5%) and in Fitzpatrick skin phototypes II (12.8%), III (36.3%), and IV (39.7%). Skin phototypes II and III and family history of melasma had early onset of the disorder when compared with skin phototypes IV, V, and VI (P<0.0001). Similar results were also observed when these same groups were compared with the absence of family history (P<0.0001). Extra-facial melasma was more frequent in postmenopausal women compared with those who were not experiencing menopause (14.2% vs. 3.5%, P<0.0001). Data suggested that the age of melasma onset are related to skin phototypes and family history. Additionally, extra-facial melasma was more common in menopausal women. This is the first study on the epidemiology of melasma in Brazil involving a large sample of the population. These data can be a source of new relevant research on the cause and development of melasma. © 2013 The International Society of Dermatology.
NASA Astrophysics Data System (ADS)
Mehta, Dalip Singh; Ahmad, Azeem; Dubey, Vishesh; Singh, Veena; Butola, Ankit; Mohanty, Tonmoy; Nandi, Sreyankar
2018-02-01
We report longitudinal spatial coherence (LSC) gated high-resolution tomography and quantitative phase microscopy of biological cells and tissues with uniform illumination using laser as a light source. To accomplish this a pseudo thermal light source was synthesized by passing laser beams through an optical system, which is basically a speckle reduction system with combined effect of spatial, temporal, angular and polarisation diversity. The longitudinal spatial coherence length of such light was significantly reduced by synthesizing a pseudo thermal source with the combined effect of spatial, angular and temporal diversity. This results in a low spatially coherent (i.e., broad angular frequency spectrum) light source with narrow temporal frequency spectrum. Light from such a pseudo thermal light source was passed through an interference microscope with varying magnification, such as, 10X and 50X. The interference microscope was used for full-field OCT imaging of multilayer objects and topography of industrial objects. Experimental results of optical sectioning of multilayer biological objects with high axial-resolution less than 10μm was achieved which is comparable to broadband white light source. The synthesized light source with reduced speckles having uniform illumination on the sample, which can be very useful for fluorescence microscopy as well as quantitative phase microscopy with less phase noise. The present system does not require any dispersion compensation optical system for biological samples as a highly monochromatic light source is used.
Microwave-driven ultraviolet light sources
Manos, Dennis M.; Diggs, Jessie; Ametepe, Joseph D.
2002-01-29
A microwave-driven ultraviolet (UV) light source is provided. The light source comprises an over-moded microwave cavity having at least one discharge bulb disposed within the microwave cavity. At least one magnetron probe is coupled directly to the microwave cavity.
Charge transport in highly efficient iridium cored electrophosphorescent dendrimers
NASA Astrophysics Data System (ADS)
Markham, Jonathan P. J.; Samuel, Ifor D. W.; Lo, Shih-Chun; Burn, Paul L.; Weiter, Martin; Bässler, Heinz
2004-01-01
Electrophosphorescent dendrimers are promising materials for highly efficient light-emitting diodes. They consist of a phosphorescent core onto which dendritic groups are attached. Here, we present an investigation into the optical and electronic properties of highly efficient phosphorescent dendrimers. The effect of dendrimer structure on charge transport and optical properties is studied using temperature-dependent charge-generation-layer time-of-flight measurements and current voltage (I-V) analysis. A model is used to explain trends seen in the I-V characteristics. We demonstrate that fine tuning the mobility by chemical structure is possible in these dendrimers and show that this can lead to highly efficient bilayer dendrimer light-emitting diodes with neat emissive layers. Power efficiencies of 20 lm/W were measured for devices containing a second-generation (G2) Ir(ppy)3 dendrimer with a 1,3,5-tris(2-N-phenylbenzimidazolyl)benzene electron transport layer.
NASA Astrophysics Data System (ADS)
Kenar, Necla; Lim, H. S.; Mirzaaghasi, Amin
2014-02-01
New design of the excitation light source that can stably generate light with center wavelengths of 450nm, 530nm, 632.8nm and white light for auto-fluorescence(AF) and photodynamic diagnosis(PDD) of cancer in clinics in a single system is presented in this study. The light source consists of Xenon Lamp (300W), light guide module including motorize filter wheel equipped with optical filters with corresponding to wavelength bands, servo motor, motorize iris, a cooling system, power supply and optical transmission part for the output light. The transmission part of the light source was developed to collimate the light with desired wavelength into input of fiber optic. Output powers are obtained average 99.91 mW for 450+/-40 nm, 111.01 mW for 530+/-10nm, and 78.50 mW for 632.8+/-10nm.
High power LED standard light sources for photometric applications
NASA Astrophysics Data System (ADS)
Ivashin, Evgeniy; Ogarev, Sergey; Khlevnoy, Boris; Shirokov, Stanislav; Dobroserdov, Dmitry; Sapritsky, Victor
2018-02-01
High power LED light sources have been developed as possible new VNIIOFI standard sources for luminous intensity, luminous flux and colour measurements. Stability, repeatability and spatial uniformity of the sources were investigated and demonstrated high accuracy and homogeneity. The paper describes different tests on one of the manufactured sources. In the future, these LED light sources are planned to be used as standard luminous flux sources to transfer the units of luminous intensity and luminous flux from gonio-spectrometer to sphere-spectrometer.
A technique for phase correction in Fourier transform spectroscopy
NASA Astrophysics Data System (ADS)
Artsang, P.; Pongchalee, P.; Palawong, K.; Buisset, C.; Meemon, P.
2018-03-01
Fourier transform spectroscopy (FTS) is a type of spectroscopy that can be used to analyze components in the sample. The basic setup that is commonly used in this technique is "Michelson interferometer". The interference signal obtained from interferometer can be Fourier transformed into the spectral pattern of the illuminating light source. To experimentally study the concept of the Fourier transform spectroscopy, the project started by setup the Michelson interferometer in the laboratory. The implemented system used a broadband light source in near infrared region (0.81-0.89 μm) and controlled the movable mirror by using computer controlled motorized translation stage. In the early study, there is no sample the interference path. Therefore, the theoretical spectral results after the Fourier transformation of the captured interferogram must be the spectral shape of the light source. One main challenge of the FTS is to retrieve the correct phase information of the inferferogram that relates with the correct spectral shape of the light source. One main source of the phase distortion in FTS that we observed from our system is the non-linear movement of the movable reference mirror of the Michelson interferometer. Therefore, to improve the result, we coupled a monochromatic light source to the implemented interferometer. We simultaneously measured the interferograms of the monochromatic and broadband light sources. The interferogram of the monochromatic light source was used to correct the phase of the interferogram of the broadband light source. The result shows significant improvement in the computed spectral shape.
Hartmann, Sébastien; Elsäßer, Wolfgang
2017-01-01
Initially, ghost imaging (GI) was demonstrated with entangled light from parametric down conversion. Later, classical light sources were introduced with the development of thermal light GI concepts. State-of-the-art classical GI light sources rely either on complex combinations of coherent light with spatially randomizing optical elements or on incoherent lamps with monochromating optics, however suffering strong losses of efficiency and directionality. Here, a broad-area superluminescent diode is proposed as a new light source for classical ghost imaging. The coherence behavior of this spectrally broadband emitting opto-electronic light source is investigated in detail. An interferometric two-photon detection technique is exploited in order to resolve the ultra-short correlation timescales. We thereby quantify the coherence time, the photon statistics as well as the number of spatial modes unveiling a complete incoherent light behavior. With a one-dimensional proof-of-principle GI experiment, we introduce these compact emitters to the field which could be beneficial for high-speed GI systems as well as for long range GI sensing in future applications. PMID:28150737
NASA Astrophysics Data System (ADS)
Su, Wan-Ching; Chang, Ting-Chang; Liao, Po-Yung; Chen, Yu-Jia; Chen, Bo-Wei; Hsieh, Tien-Yu; Yang, Chung-I.; Huang, Yen-Yu; Chang, Hsi-Ming; Chiang, Shin-Chuan; Chang, Kuan-Chang; Tsai, Tsung-Ming
2017-03-01
This paper investigates the degradation behavior of InGaZnO thin film transistors (TFTs) under negative bias illumination stress (NBIS). TFT devices with two different source and drain layouts were exanimated: one having a parallel format electrode and the other with UI format electrode. UI means that source/drain electrodes shapes is defined as a forked-shaped structure. The I-V curve of the parallel electrode exhibited a symmetric degradation under forward and reverse sweeping in the saturation region after 1000 s NBIS. In contrast, the I-V curve of the UI electrode structure under similar conditions was asymmetric. The UI electrode structure also shows a stretch-out phenomenon in its C-V measurement. Finally, this work utilizes the ISE-Technology Computer Aided Design (ISE-TCAD) system simulations, which simulate the electron field and IV curves, to analyze the mechanisms dominating the parallel and UI device degradation behaviors.
NASA Technical Reports Server (NTRS)
Dickey, J. M.
2010-01-01
In order to establish the position of the center of mass of the Earth in the International Celestial Reference Frame, observations of the Global Positioning Satellite (GPS) constellation using the IVS network are important. With a good frame-tie between the coordinates of the IVS telescopes and nearby GPS receivers, plus a common local oscillator reference signal, it should be possible to observe and record simultaneously signals from the astrometric calibration sources and the GPS satellites. The standard IVS solution would give the atmospheric delay and clock offsets to use in analysis of the GPS data. Correlation of the GPS signals would then give accurate orbital parameters of the satellites in the ICRF reference frame, i.e., relative to the positions of the astrometric sources. This is particularly needed to determine motion of the center of mass of the earth along the rotation axis.
Sangami, G; Dharmaraj, N
2012-11-01
Nanocrystalline, tin(IV) oxide (SnO(2)) particles has been prepared by thermal decomposition of tin oxalate precursor obtained from the reactions of tin(IV) chloride and sodium oxalate using eggshell membrane (ESM). The as-prepared SnO(2) nanoparticles were characterized by thermal studies, transmission electron microscopy (TEM), powder X-ray diffraction (XRD), Raman, FT-IR and UV-visible studies and used as a photocatalyst for the degradation of rhodamine-B (Rh-B) dye. The size of the prepared nanoparticles was in the range of 5-12nm as identified from the TEM images. Powder XRD data revealed the presence of a tetragonal, rutile crystalline phase of the tin(IV) oxide nanoparticles. Thermal analysis showed that the decomposition of tin oxalate precursor to yield the titled tin(IV) oxide nanoparticles was completed below 500°C. The extent of degradation of Rh-B in the presence of SnO(2) monitored by absorption spectral measurements demonstrated that 94.48% of the selected dye was degraded upon irradiation with UV light for 60 min. Copyright © 2012 Elsevier B.V. All rights reserved.
Spatial Light Modulators as Optical Crossbar Switches
NASA Technical Reports Server (NTRS)
Juday, Richard
2003-01-01
A proposed method of implementing cross connections in an optical communication network is based on the use of a spatial light modulator (SLM) to form controlled diffraction patterns that connect inputs (light sources) and outputs (light sinks). Sources would typically include optical fibers and/or light-emitting diodes; sinks would typically include optical fibers and/or photodetectors. The sources and/or sinks could be distributed in two dimensions; that is, on planes. Alternatively or in addition, sources and/or sinks could be distributed in three dimensions -- for example, on curved surfaces or in more complex (including random) three-dimensional patterns.
Mamba, Gcina; Mbianda, Xavier Yangkou; Mishra, Ajay Kumar
2015-07-01
A simple sol-gel method was employed to prepare gadolinium, nitrogen and sulphur tridoped titania decorated on oxidised multiwalled carbon nanotubes (MWCNT/Gd,N,S-TiO2), using titanium (IV) butoxide and thiourea as titanium and nitrogen and sulphur source, respectively. Samples of varying gadolinium loadings (0.2%, 0.6%, 1.0% and 3.0% Gd3+) relative to titania were prepared to investigate the effect of gadolinium loading and the amounts of carbon nanotubes, nitrogen and sulphur were kept constant for all the samples. Furthermore, the prepared nanocomposites were evaluated for the degradation of naphthol blue black (NBB) in water under simulated solar light irradiation. Higher degradation efficiency (95.7%) was recorded for the MWCNT/Gd,N,S-TiO2 (0.6% Gd) nanocomposites. The higher photocatalytic activity is attributed to the combined effect of improved visible light absorption and charge separation due to the synergistic effect of Gd, MWCNTs, N, S and TiO2. Total organic carbon (TOC) analysis revealed a higher degree of complete mineralisation of naphthol blue black (78.0% TOC removal) which minimises the possible formation of toxic degradation by-products such as the aromatic amines. The MWCNT/Gd,N,S-TiO2 (0.6% Gd) was fairly stable and could be re-used for five times, reaching a maximum degradation efficiency of 91.8% after the five cycles. Copyright © 2015. Published by Elsevier B.V.
Shenashen, Mohamed A; Kawada, Satoshi; Selim, Mahmoud M; Morsy, Wafaa M; Yamaguchi, Hitoshi; Alhamid, Abdulaziz A; Ohashi, Naoki; Ichinose, Izumi; El-Safty, Sherif A
2017-06-14
This work describes densely interlinked bushy "tree-like chains" characterized by neatly branched sphere dendrites (bushy sphere dendrites, BSD) with long fan-like, husk-shaped branching paths that extend longitudinally from the core axis of the {110}-exposed plane. We confirmed that the hierarchical dendrite surfaces created bowls of swirled caves along the tree-tube in the mat-like branches. These surfaces had high-index catalytic site facets associated with the formation of ridges/defects on the dominant {110}-top-cover surface. These swirled caves along the branches were completely filled with 50-100 nm poly-CN nano-sphere-fossils with orb-like appearance. Such structural features are key issues of the inherent surface reactivity of a powerful catalyst/trapper, enabling photocatalytic oxidation and trapping of extremely toxic arsenite (AsO 3 3- ) species and photo-induced recovery of arsenate (AsO 4 3- ) products from catalyst surfaces. The light-induced release of produced AsO 4 3- from BSD indicates (i) highly controlled waste collection/management (i.e., recovery), (ii) low cost and ecofriendly photo-adsorbent, (iii) selective trapping of real sample water to produce water-free arsenite species; (iv) multiple reuse cycles of catalysts (i.e., reduced waste volume). Matrixed dendrites, covered with 3D microscopic sphere cores that capture solar-light, trap toxins, and are triggered by light, were designed. These dendrites can withstand indoor and outdoor recovery of toxins from water sources.
Comparative Study of Light Sources for Household
NASA Astrophysics Data System (ADS)
Pawlak, Andrzej; Zalesińska, Małgorzata
2017-03-01
The article describes test results that provided the ground to define and evaluate basic photometric, colorimetric and electric parameters of selected, widely available light sources, which are equivalent to a traditional incandescent 60-Watt light bulb. Overall, one halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In general, it was concluded that in most cases (branded products, in particular) the measured and calculated parameters differ from the values declared by manufacturers only to a small degree. LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower.
Polarization Dependent Whispering Gallery Modes in Microspheres
NASA Technical Reports Server (NTRS)
Adamovsky, Grigory (Inventor); Wrbanek, Susan Y. (Inventor)
2016-01-01
A tunable resonant system is provided and includes a microsphere that receives an incident portion of a light beam generated via a light source, the light beam having a fundamental mode, a waveguide medium that transmits the light beam from the light source to the microsphere, and a polarizer disposed in a path of the waveguide between the light source and the microsphere. The incident portion of the light beam creates a fundamental resonance inside the microsphere. A change in a normalized frequency of the wavelength creates a secondary mode in the waveguide and the secondary mode creates a secondary resonance inside the microsphere.
Particle measurement systems and methods
Steele, Paul T [Livermore, CA
2011-10-04
A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.
NASA Astrophysics Data System (ADS)
Chen, Janet; Rinne-Garmston, Katja; Penttilä, Reijo; Hobbie, Erik; Mäkipää, Raisa
2016-04-01
To predict effects of global change on fungal community structure and the consequential effects on carbon (C) and nitrogen (N) cycling, we first need to understand different fungal sources of C and N. We determined sources of C and N by measuring δ15N and δ13C of an extensive collection of ectomycorrhizal and saprotrophic sporocarps and their potential substrates from Norway spruce (Picea abies) stands in southern Finland. The substrates included organic soil, roots in organic soil, mineral soil, roots in mineral soil, moss, needles, needles in litter, branches, twigs in litter, wood and decay wood from stages I-V. Notably, δ15N and δ13C analysis of wood in decay stages I-V was a novel measurement, as were our associations between wood decay fungi and the decay stage of trees. Decay stage of wood significantly correlated with the δ15N and δ13C of associated saprotrophic wood decay fungi species. Fungi were lower in δ15N by 0.3-0.7‰ when associated with decay wood in stages II and III compared to I and IV and higher in δ13C by 0.9-1.2‰ when associated with decay stage I compared to decay stages II-IV. The ectomycorrhizal fungi, Piloderma fallax, was significantly correlated with 15N enrichment of decay wood upon its introduction in decay stages III and IV that continued to the later decay stage V, with δ15N of decay stage V 1.5‰ higher than decay stage IV. These results indicate that wood decay fungi rely on C and N from various wood decay stages and influence C and N pools of wood as well. Litter decay fungi were lower in δ13C than wood decay fungi by 1.9‰ and higher in δ15N by 3‰ and isotopically tracked their C and N sources. Calocera viscosa, Gymnopus acervatus, and Leotia lubrica were highly 15N-enriched compared to other saprotrophic fungi and they had δ15N values similar to fungi with hydrophobic ectomycorrhizae indicating function more similar to ectomycorrhizal fungi or N sources similar to this functional group. Similar to other studies, ectomycorrhizal fungi were 15N-enriched relative to saprotrophic fungi and fungi with hydrophobic ectomycorrhizae were 15N-enriched compared to fungi with hydrophilic ectomycorrhizae by 3.6‰. δ15N and δ13C values indicate that ectomycorrhizal fungi derive C from plant sugars similar to woody substrate, and acquire N from older sources within the litter layer and deeper in organic and mineral soils, with hydrophobic ectomycorrhizae using older sources of N than hydrophilic ectomycorrhizae. Interestingly, Entoloma cetratum with hydrophilic ectomycorrhizae and Hydnum repandum with hydrophobic ectomycorrhizae both had abnormally high δ15N values that suggest an irregular 15N-enriched source of N, likely from a higher 15N-enriched trophic level.
Investigation on RGB laser source applied to dynamic photoelastic experiment
NASA Astrophysics Data System (ADS)
Li, Songgang; Yang, Guobiao; Zeng, Weiming
2014-06-01
When the elastomer sustains the shock load or the blast load, its internal stress state of every point will change rapidly over time. Dynamic photoelasticity method is an experimental stress analysis method, which researches the dynamic stress and the stress wave propagation. Light source is one of very important device in dynamic photoelastic experiment system, and the RGB laser light source applied in dynamic photoelastic experiment system is innovative and evolutive to the system. RGB laser is synthesized by red laser, green laser and blue laser, either as a single wavelength laser light source, also as synthesized white laser light source. RGB laser as a light source for dynamic photoelastic experiment system, the colored isochromatic can be captured in dynamic photoelastic experiment, and even the black zero-level stripe can be collected, and the isoclinics can also be collected, which conducively analysis and study of transient stress and stress wave propagation. RGB laser is highly stable and continuous output, and its power can be adjusted. The three wavelengths laser can be synthesized by different power ratio. RGB laser light source used in dynamic photoelastic experiment has overcome a number of deficiencies and shortcomings of other light sources, and simplifies dynamic photoelastic experiment, which has achieved good results.
Vachiramon, Vasanop; Jurairattanaporn, Natthachat; Harnchoowong, Sarawin; Chayavichitsilp, Pamela
2018-02-01
Skin hyperpigmentation is a frequently encountered problem, particularly in darker skin types. Unfortunately, standard treatments for this condition have shown disappointing results. High-intensity focused ultrasound (HIFU) is commonly indicated for skin laxity, but recently was used to treat UV-induced hyperpigmentation in animal models. This study is aimed to evaluate the efficacy and safety of high-intensity focused ultrasound for UVB-induced hyperpigmentation in human subjects. A randomized, evaluator-blinded pilot study was conducted on 20 subjects. Each subject was induced three hyperpigmentary spots by local broadband UVB. After 2 weeks, each spot was randomly allocated to control, low-energy, and high-energy HIFU. Subjects were instructed to follow up weekly for a duration of 1 month. Lightness index measurements, mean improvement scores, subjects' satisfaction, pain scores, and side effects were evaluated. All 20 subjects completed the study. Fourteen subjects had Fitzpatrick (FPT) skin type III and six subjects had FPT skin type IV. Twelve subjects showed greater improvement at control sites while eight subjects showed greater improvement at HIFU-treated sites. In FPT skin type III, HIFU appeared to be inferior to control in both lightness index and mean improvement scores, but in FPT skin type IV, HIFU had greater lightness index improvement and higher improvement scores than control. Side effects were more frequent in high-energy-treated areas. Focused ultrasound may be offered in some patients with hyperpigmentary conditions. More research is needed to determine proper energy settings for optimal outcome.
Research on starlight hardware-in-the-loop simulator
NASA Astrophysics Data System (ADS)
Zhang, Ying; Gao, Yang; Qu, Huiyang; Liu, Dongfang; Du, Huijie; Lei, Jie
2016-10-01
The starlight navigation is considered to be one of the most important methods for spacecraft navigation. Starlight simulation system is a high-precision system with large fields of view, designed to test the starlight navigation sensor performance on the ground. A complete hardware-in-the-loop simulation of the system has been built. The starlight simulator is made up of light source, light source controller, light filter, LCD, collimator and control computer. LCD is the key display component of the system, and is installed at the focal point of the collimator. For the LCD cannot emit light itself, so light source and light source power controller is specially designed for the brightness demanded by the LCD. Light filter is designed for the dark background which is also needed in the simulation.
National Synchrotron Light Source
BNL
2017-12-09
A tour of Brookhaven's National Synchrotron Light Source (NSLS), hosted by Associate Laboratory Director for Light Sources, Stephen Dierker. The NSLS is one of the world's most widely used scientific research facilities, hosting more than 2,500 guest researchers each year. The NSLS provides intense beams of infrared, ultraviolet, and x-ray light for basic and applied research in physics, chemistry, medicine, geophysics, environmental, and materials sciences.
NASA Astrophysics Data System (ADS)
Gan, Ruting; Guo, Zhenning; Lin, Jieben
2015-09-01
To decrease the risk of bilirubin encephalopathy and minimize the need for exchange transfusions, we report a novel design for light source of light-emitting diode (LED)-based neonatal jaundice therapeutic device (NJTD). The bilirubin absorption spectrum in vivo was regarded as target. Based on spectral constructing theory, we used commercially available LEDs with different peak wavelengths and full width at half maximum as matching light sources. Simple genetic algorithm was first proposed as the spectral matching method. The required LEDs number at each peak wavelength was calculated, and then, the commercial light source sample model of the device was fabricated to confirm the spectral matching technology. In addition, the corresponding spectrum was measured and the effect was analyzed finally. The results showed that fitted spectrum was very similar to the target spectrum with 98.86 % matching degree, and the actual device model has a spectrum close to the target with 96.02 % matching degree. With higher fitting degree and efficiency, this matching algorithm is very suitable for light source matching technology of LED-based spectral distribution, and bilirubin absorption spectrum in vivo will be auspicious candidate for the target spectrum of new LED-based NJTD light source.
NASA Astrophysics Data System (ADS)
Kwon, Hyeokjun; Kang, Yoojin; Jang, Junwoo
2017-09-01
Color fidelity has been used as one of indices to evaluate the performance of light sources. Since the Color Rendering Index (CRI) was proposed at CIE, many color fidelity metrics have been proposed to increase the accuracy of the metric. This paper focuses on a comparison of the color fidelity metrics in an aspect of accuracy with human visual assessments. To visually evaluate the color fidelity of light sources, we made a simulator that reproduces the color samples under lighting conditions. In this paper, eighteen color samples of the Macbeth color checker under test light sources and reference illuminant for each of them are simulated and displayed on a well-characterized monitor. With only a spectrum set of the test light source and reference illuminant, color samples under any lighting condition can be reproduced. In this paper, the spectrums of the two LED and two OLED light sources that have similar values of CRI are used for the visual assessment. In addition, the results of the visual assessment are compared with the two color fidelity metrics that include CRI and IES TM-30-15 (Rf), proposed by Illuminating Engineering Society (IES) in 2015. Experimental results indicate that Rf outperforms CRI in terms of the correlation with visual assessment.
NASA Technical Reports Server (NTRS)
Holley, Daniel C.; Heeke, D.; Mele, G.
1999-01-01
Currently, the light sources most commonly used in animal habitat lighting are cool white fluorescent or incandescent lamps. We evaluated a novel light-emitting diode (LED) light source for use in animal habitat lighting by comparing its effectiveness to cool white fluorescent light (CWF) in suppressing pineal gland melatonin and maintaining normal retinal physiology and morphology in the rat. Results of pineal melatonin suppression experiments showed equal suppression of pineal melatonin concentrations for LED light and CWF light at five different light illuminances (100, 40, 10, 1 and 0.1 lux). There were no significant differences in melatonin suppression between LED and CWF light when compared to unexposed controls. Retinal physiology was evaluated using electroretinography. Results show no differences in a-wave implicit times and amplitudes or b-wave implicit times and amplitudes between 100-lux LED-exposed rats and 100-lux CWF-exposed rats. Results of retinal histology assessment show no differences in retinal thickness rod outer segment length and number of rod nuclei between rats exposed to 100-lux LED and 100-lux CWF for days. Furthermore, the retinal pigmented epithelium and rod outer segments of all eyes observed were in good condition and of normal thickness. This study indicates that LED light does not cause retinal damage and can suppress pineal melatonin at similar intensities as a conventional CWF light source. These data suggest that LED light sources may be suitable replacements for conventional light sources used in the lighting of rodent vivariums while providing many mechanical and economical advantages.
Spectral characteristics of light sources for S-cone stimulation.
Schlegelmilch, F; Nolte, R; Schellhorn, K; Husar, P; Henning, G; Tornow, R P
2002-11-01
Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.
Olds, Kelly; Byard, Roger W; Winskog, Calle; Langlois, Neil E I
2017-03-01
Bruising is frequently documented in cases of violence for use as forensic evidence. However, bruises can be overlooked if they are not visible to the naked eye. Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent. However, there is a significant gap in knowledge surrounding this technique as it has not been validated against histology to confirm that bruising is genuinely being enhanced. A recent study evaluated the ability of alternate light sources to enhance visibility of bruises using a pigskin model. However, histological confirmation of bruising in humans using these light sources has not yet been performed. In this study, embalmed and non-embalmed human cadavers were used. Bodies were surveyed with alternate light sources, and enhanced regions that were unapparent under white light were photographed with the alternate light sources and sampled for histological assessment. Immunohistochemical staining for the red blood cell surface protein glycophorin was used determine if the enhanced area was a bruise (defined by the presence of extravasated erythrocytes). Photographs of areas confirmed to be bruises were analyzed using the program Fiji to measure enhancement, which was defined as an increase in the measured transverse diameter. In the non-embalmed and the embalmed cadavers violet alternate light produced the greatest enhancement of histologically confirmed bruises, followed by blue (both p < 0.0001). Regions that were not confirmed as bruises also enhanced, indicating that light sources may not be specific. This suggests that the use of light sources to enhance the visibility of bruising should be undertaken with caution and further studies are required.
Hansen, A.D.
1988-01-25
An improved aethalometer having a single light source and a single light detector and two light paths from the light source to the light detector. A quartz fiber filter is inserted in the device, the filter having a collection area in one light path and a reference area in the other light path. A gas flow path through the aethalometer housing allows ambient air to flow through the collection area of the filter so that aerosol particles can be collected on the filter. A rotating disk with an opening therethrough allows light for the light source to pass alternately through the two light paths. The voltage output of the detector is applied to a VCO and the VCO pulses for light transmission separately through the two light paths, are counted and compared to determine the absorption coefficient of the collected aerosol particles. 5 figs.
Study of Selecting on Light Source Used for Micro-algae Cultivation in Space
NASA Astrophysics Data System (ADS)
Ai, Weidang; Ai, Weidang; Guo, Shuang-Sheng; Gao, Feng; Tang, Yong-Kang; Qin, Li-Feng
To select suitable light source for micro-algae cultivation in future space station, the selected Spirulina plastensis(No.7) were cultured under different lightening qualities, including six light sources that were made up of different combinations of red and blue light-emitting diode(LED). The growth, photosynthetic efficiency and nutrition quality of the Spirulina, were analyzed. From the experiments, the red light may promote the cumulation of biomass of the Spirulina, and the cumulating rate was the highest under all red light source, but the syntheses of protein, phycobiliprotein, β-carotene, VE and other nutrients needs a certain portion of blue light; yet, the complete blue light condition is not favorable to the growth of Spirulina, and may bring pollution by chlorella and other kinds of micro-algae. It is concluded that the LEDs can be used as the light resource of micro-algae cultivation. The normal growth and development of microalgae need two light sources of both red and blue LEDs. The comprehensive analyses of the various factors that affect the growth of Spirulina, such as nutrition quality and photosynthetic activities, etc., showed that the combination of 80% red and 20% blue LED is the optimum one among those tested combinations. Key word: light-emitting diode; micro-algae; controlled ecological life support system (CELSS); space cultivation
Grossman, Mark W.; George, William A.; Pai, Robert Y.
1985-01-01
A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.
Updates on the African Synchrotron Light Source (AfLS) Project
NASA Astrophysics Data System (ADS)
Dobbins, Tabbetha; Mtingwa, Sekazi; Wague, Ahmadou; Connell, Simon; Masara, Brian; Ntsoane, Tshepo; Norris, Lawrence; Winick, Herman; Evans-Lutterodt, Kenneth; Hussein, Tarek; Maresha, Feene; McLaughlin, Krystle; Oladijo, Philip; Du Plessis, Esna; Murenzi, Romain; Reed, Kennedy; Sette, Francesco; Werin, Sverker; Dorfan, Jonathan; Yousef, Mohammad
Africa is the only habitable continent without a synchrotron light source. A full steering committee was elected at the African Light Source (AfLS) conference on November 16-20, 2015 at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. The conference brought together African scientists, policy makers, and stakeholders to discuss a synchrotron light source in Africa. Firm outcomes of the Conference were a set of resolutions and a roadmap. Additionally, a collaborative proposal to promote Advanced Light Sources and crystallographic sciences in targeted regions of the world was submitted by the International Union of Pure and Applied Physics (IUPAP) and the International Union of Crystallography (IUCr) to the International Council for Science (ICSU). www.africanlightsource.org.
Discrete wavelength-locked external cavity laser
NASA Technical Reports Server (NTRS)
Pilgrim, Jeffrey S. (Inventor); Silver, Joel A. (Inventor)
2005-01-01
An external cavity laser (and method of generating laser light) comprising: a laser light source; means for collimating light output by the laser light source; a diffraction grating receiving collimated light; a cavity feedback mirror reflecting light received from the diffraction grating back to the diffraction grating; and means for reliably tuning the external cavity laser to discrete wavelengths.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-29
...-readiness processes of potential contractors and subcontractors as a part of the source selection process... Supplement (DFARS) subpart 215.3, Source Selection. It amends DFARS 215.304(c) by adding paragraph (iv) to... and subcontractors shall be considered as a part of the source selection process for major defense...
Code of Federal Regulations, 2013 CFR
2013-01-01
... accidents; (iv) For devices containing byproduct material, the radiation profile of a prototype device; (v... source or device pertinent to an evaluation of its radiation safety, including: (i) The byproduct...) Instructions for handling and storing the source or device from the radiation safety standpoint; these...
Code of Federal Regulations, 2014 CFR
2014-01-01
... accidents; (iv) For devices containing byproduct material, the radiation profile of a prototype device; (v... source or device pertinent to an evaluation of its radiation safety, including: (i) The byproduct...) Instructions for handling and storing the source or device from the radiation safety standpoint; these...
Plant Growth Absorption Spectrum Mimicking Light Sources
Jou, Jwo-Huei; Lin, Ching-Chiao; Li, Tsung-Han; Li, Chieh-Ju; Peng, Shiang-Hau; Yang, Fu-Chin; Justin Thomas, K. R.; Kumar, Dhirendra; Chi, Yun; Hsu, Ban-Dar
2015-01-01
Plant factories have attracted increasing attention because they can produce fresh fruits and vegetables free from pesticides in all weather. However, the emission spectra from current light sources significantly mismatch the spectra absorbed by plants. We demonstrate a concept of using multiple broad-band as well as narrow-band solid-state lighting technologies to design plant-growth light sources. Take an organic light-emitting diode (OLED), for example; the resulting light source shows an 84% resemblance with the photosynthetic action spectrum as a twin-peak blue dye and a diffused mono-peak red dye are employed. This OLED can also show a greater than 90% resemblance as an additional deeper red emitter is added. For a typical LED, the resemblance can be improved to 91% if two additional blue and red LEDs are incorporated. The approach may facilitate either an ideal use of the energy applied for plant growth and/or the design of better light sources for growing different plants. PMID:28793503
Computation and visualization of the MacAdam limits for any lightness, hue angle, and light source
NASA Astrophysics Data System (ADS)
Martínez-Verdú, Francisco; Perales, Esther; Chorro, Elisabet; de Fez, Dolores; Viqueira, Valentín; Gilabert, Eduardo
2007-06-01
We present a systematic algorithm capable of searching for optimal colors for any lightness L* (between 0 and 100), any illuminant (D65, F2, F7, F11, etc.), and any light source reported by CIE. Color solids are graphed in some color spaces (CIELAB, SVF, DIN99d, and CIECAM02) by horizontal (constant lightness) and transversal (constant hue angle) sections. Color solids plotted in DIN99d and CIECAM02 color spaces look more spherical or homogeneous than the ones plotted in CIELAB and SVF color spaces. Depending on the spectrum of the light source or illuminant, the shape of its color solid and its content (variety of distinguishable colors, with or without color correspondence) change drastically, particularly with sources whose spectrum is discontinuous and/or very peaked, with correlated color temperature lower than 5500 K. This could be used to propose an absolute colorimetric quality index for light sources comparing the volumes of their gamuts, in a uniform color space.
GRB 120729A: External Shock Origin for Both the Prompt Gamma-Ray Emission and Afterglow
NASA Astrophysics Data System (ADS)
Huang, Li-Ye; Wang, Xiang-Gao; Zheng, WeiKang; Liang, En-Wei; Lin, Da-bin; Zhong, Shu-Qing; Zhang, Hai-Ming; Huang, Xiao-Li; Filippenko, Alexei V.; Zhang, Bing
2018-06-01
Gamma-ray burst (GRB) 120729A was detected by Swift/BAT and Fermi/GBM, and then rapidly observed by Swift/XRT, Swift/UVOT, and ground-based telescopes. It had a single long and smooth γ-ray emission pulse, which extends continuously to the X-rays. We report Lick/KAIT observations of the source, and make temporal and spectral joint fits of the multiwavelength light curves of GRB 120729A. It exhibits achromatic light-curve behavior, consistent with the predictions of the external shock model. The light curves are decomposed into four typical phases: onset bump (Phase I), normal decay (Phase II), shallow decay (Phase III), and post-jet break (Phase IV). The spectral energy distribution (SED) evolves from prompt γ-ray emission to the afterglow with a photon index from Γ γ = 1.36 to Γ ≈ 1.75. There is no obvious evolution of the SED during the afterglow. The multiwavelength light curves from γ-ray to optical can be well modeled with an external shock by considering energy injection, and a time-dependent microphysics model with {ε }B\\propto {t}{α B} for the emission at early times, T< {T}0+157 {{s}}. Therefore, we conclude that both the prompt γ-ray emission and afterglow of GRB 120729A have the same external shock physical origin. Our model indicates that the ɛ B evolution can be described as a broken power-law function with α B,1 = 0.18 ± 0.04 and α B,2 = 0.84 ± 0.04. We also systematically investigate single-pulse GRBs in the Swift era, finding that only a small fraction of GRBs (GRBs 120729A, 051111, and 070318) are likely to originate from an external shock for both the prompt γ-ray emission and afterglow.
Structure of sunspot light bridges in the chromosphere and transition region
NASA Astrophysics Data System (ADS)
Rezaei, R.
2018-01-01
Context. Light bridges (LBs) are elongated structures with enhanced intensity embedded in sunspot umbra and pores. Aims: We studied the properties of a sample of 60 LBs observed with the Interface Region Imaging Spectrograph (IRIS). Methods: Using IRIS near- and far-ultraviolet spectra, we measured the line intensity, width, and Doppler shift; followed traces of LBs in the chromosphere and transition region (TR); and compared LB parameters with umbra and quiet Sun. Results: There is a systematic emission enhancement in LBs compared to nearby umbra from the photosphere up to the TR. Light bridges are systematically displaced toward the solar limb at higher layers: the amount of the displacement at one solar radius compares well with the typical height of the chromosphere and TR. The intensity of the LB sample compared to the umbra sample peaks at the middle/upper chromosphere where they are almost permanently bright. Spectral lines emerging from the LBs are broader than the nearby umbra. The systematic redshift of the Si IV line in the LB sample is reduced compared to the quiet Sun sample. We found a significant correlation between the line width of ions arising at temperatures from 3 × 104 to 1.5 × 105 K as there is also a strong spatial correlation among the line and continuum intensities. In addition, the intensity-line width relation holds for all spectral lines in this study. The correlations indicate that the cool and hot plasma in LBs are coupled. Conclusions: Light bridges comprise multi-temperature and multi-disciplinary structures extending up to the TR. Diverse heating sources supply the energy and momentum to different layers, resulting in distinct dynamics in the photosphere, chromosphere, and TR.
Method and Apparatus for Characterizing Pressure Sensors using Modulated Light Beam Pressure
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor)
2003-01-01
Embodiments of apparatuses and methods are provided that use light sources instead of sound sources for characterizing and calibrating sensors for measuring small pressures to mitigate many of the problems with using sound sources. In one embodiment an apparatus has a light source for directing a beam of light on a sensing surface of a pressure sensor for exerting a force on the sensing surface. The pressure sensor generates an electrical signal indicative of the force exerted on the sensing surface. A modulator modulates the beam of light. A signal processor is electrically coupled to the pressure sensor for receiving the electrical signal.
Observational properties of decameter type IV bursts
NASA Astrophysics Data System (ADS)
Melnik, Valentin; Brazhenko, Anatoly; Rucker, Helmut; Konovalenko, Alexander; Briand, Carine; Dorovskyy, Vladimir; Zarka, Philippe; Frantzusenko, Anatoly; Panchenko, Michael; Poedts, Stefan; Zaqarashvili, Teimuraz; Shergelashvili, Bidzina
2013-04-01
Oscillations of decameter type IV bursts were registered during observations of solar radio emission by UTR-2, URAN-2 and NDA in 2011-2012. Large majority of these bursts were accompanied by coronal mass ejections (CMEs), which were observed by SOHO and STEREO in the visible light. Only in some cases decameter type IV bursts were not associated with CMEs. The largest periods of oscillations P were some tens of minutes. There were some modes of long periods of oscillations simultaneously. Periods of oscillations in flux and in polarization profiles were close. Detailed properties of oscillations at different frequencies were analyzed on the example of two type IV bursts. One of them was observed on April 7, 2011 when a CME happened. Another one (August 1, 2011) was registered without any CME. The 7 April type IV burst had two periods in the frames 75-85 and 35-85 minutes. Interesting feature of these oscillations is decreasing periods with time. The observed decreasing rates dP/dt equaled 0.03-0.07. Concerning type IV burst observed on August 1, 2011 the period of its oscillations increases from 17 min. at 30 MHz to 44 min. at 10 MHz. Connection of type IV burst oscillations with oscillations of magnetic arches and CMEs at corresponding altitudes are discussed. The work is fulfilled in the frame of FP7 project "SOLSPANET".
Probing the Metal Enrichment of the Intergalactic Medium at z = 5-6 Using the Hubble Space Telescope
NASA Astrophysics Data System (ADS)
Cai, Zheng; Fan, Xiaohui; Dave, Romeel; Finlator, Kristian; Oppenheimer, Ben
2017-11-01
We test the galactic outflow model by probing associated galaxies of four strong intergalactic C IV absorbers at z = 5-6 using the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) ramp narrowband filters. The four strong C IV absorbers reside at z = 5.74, 5.52, 4.95, and 4.87, with column densities ranging from N C IV = 1013.8 to 1014.8 cm-2. At z = 5.74, we detect an I-dropout Lyα emitter (LAE) candidate with a projected impact parameter of 42 physical kpc from the C IV absorber. This LAE candidate has a Lyα-based star formation rate (SFRLyα ) of 2 M ⊙ yr-1 and a UV-based SFR of 4 M ⊙ yr-1. Although we cannot completely rule out that this I-dropout emitter may be an [O II] interloper, its measured properties are consistent with the C IV powered galaxy at z = 5.74. For C IV absorbers at z = 4.95 and z = 4.87, although we detect two LAE candidates with impact parameters of 160 and 200 kpc, such distances are larger than that predicted from the simulations. Therefore, we treat them as nondetections. For the system at z = 5.52, we do not detect LAE candidates, placing a 3σ upper limit of SFRLyα ≈ 1.5 M ⊙ yr-1. In summary, in these four cases, we only detect one plausible C IV source at z = 5.74. Combining the modest SFR of the one detection and the three nondetections, our HST observations strongly support that smaller galaxies (SFRLyα ≲ 2 M ⊙ yr-1) are main sources of intergalactic C IV absorbers, and such small galaxies play a major role in the metal enrichment of the intergalactic medium at z ≳ 5.
Spatially resolved imaging of opto-electrical property variations
Nikiforov, Maxim; Darling, Seth B; Suzer, Ozgun; Guest, Jeffrey; Roelofs, Andreas
2014-09-16
Systems and methods for opto electric properties are provided. A light source illuminates a sample. A reference detector senses light from the light source. A sample detector receives light from the sample. A positioning fixture allows for relative positioning of the sample or the light source with respect to each other. An electrical signal device measures the electrical properties of the sample. The reference detector, sample detector and electrical signal device provide information that may be processed to determine opto-electric properties of the same.
2010-11-01
Connecting the Medtronic MAST Quadrant Illumination System, Radiance Illumination System, or Radiance X Illumination System--all of which are specialized fiberoptic light cables used with the company's minimally invasive spinal products--to a high-power surgical light source significantly increases the risk of patient burns. Hospitals should ensure that the products are used only with 100 W light sources and 5 mm light cables, as prescribed in the product labeling.
LEDs as light source: examining quality of acquired images
NASA Astrophysics Data System (ADS)
Bachnak, Rafic; Funtanilla, Jeng; Hernandez, Jose
2004-05-01
Recent advances in technology have made light emitting diodes (LEDs) viable in a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. This paper presents the results of comparing images taken by a videoscope using two different light sources. One of the sources is the internal metal halide lamp and the other is a LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. The paper will present the results and discuss the usefulness and shortcomings of various comparison methods.
Ji, Wei; Zhang, Chaohua; Ji, Hongwu
2017-10-01
Dipeptidyl peptidase IV (DPP-IV) played an important role in blood glucose regulation. Inhibition of DPP-IV may improve glycemic control in diabetics by preventing the rapid breakdown of incretin hormones and prolonging their physiological action. In this study, Antarctic krill (Euphausia superba) protein was hydrolyzed using animal proteolytic enzymes. The hydrolysate was purified sequentially by ultrafiltration, gel filtration chromatography and reversed phase high-performance liquid chromatography (RP-HPLC). DPP-IV inhibitory activity of the fractions achieved from Antarctic krill protein was determined by DPP-IV screening reagent kit. Two purified peptides were identified by Xevo G2-XS QTof mass spectrometer (QTOF-MS). One peptide purified was Ala-Pro (AP) with IC 50 values of 0.0530mg/mL, the other Ile-Pro-Ala (IPA) with IC 50 values of 0.0370mg/mL. They both exhibited strong DPP-IV inhibitory activity. The molecular docking analysis revealed that DPP-IV inhibition by AP and IPA was mainly due to formation of a strong interaction surface force with the 91-96 and 101-105 amino acids of the DPP-IV. Our results suggested that the protein hydrolysate from Antarctic krill can be considered as a promising natural source of DPP-IV inhibitory peptides in the management of diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.
Solid state lighting devices and methods with rotary cooling structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koplow, Jeffrey P.
Solid state lighting devices and methods for heat dissipation with rotary cooling structures are described. An example solid state lighting device includes a solid state light source, a rotating heat transfer structure in thermal contact with the solid state light source, and a mounting assembly having a stationary portion. The mounting assembly may be rotatably coupled to the heat transfer structure such that at least a portion of the mounting assembly remains stationary while the heat transfer structure is rotating. Examples of methods for dissipating heat from electrical devices, such as solid state lighting sources are also described. Heat dissipationmore » methods may include providing electrical power to a solid state light source mounted to and in thermal contact with a heat transfer structure, and rotating the heat transfer structure through a surrounding medium.« less
AutoLens: Automated Modeling of a Strong Lens's Light, Mass and Source
NASA Astrophysics Data System (ADS)
Nightingale, J. W.; Dye, S.; Massey, Richard J.
2018-05-01
This work presents AutoLens, the first entirely automated modeling suite for the analysis of galaxy-scale strong gravitational lenses. AutoLens simultaneously models the lens galaxy's light and mass whilst reconstructing the extended source galaxy on an adaptive pixel-grid. The method's approach to source-plane discretization is amorphous, adapting its clustering and regularization to the intrinsic properties of the lensed source. The lens's light is fitted using a superposition of Sersic functions, allowing AutoLens to cleanly deblend its light from the source. Single component mass models representing the lens's total mass density profile are demonstrated, which in conjunction with light modeling can detect central images using a centrally cored profile. Decomposed mass modeling is also shown, which can fully decouple a lens's light and dark matter and determine whether the two component are geometrically aligned. The complexity of the light and mass models are automatically chosen via Bayesian model comparison. These steps form AutoLens's automated analysis pipeline, such that all results in this work are generated without any user-intervention. This is rigorously tested on a large suite of simulated images, assessing its performance on a broad range of lens profiles, source morphologies and lensing geometries. The method's performance is excellent, with accurate light, mass and source profiles inferred for data sets representative of both existing Hubble imaging and future Euclid wide-field observations.
Optical detector calibrator system
NASA Technical Reports Server (NTRS)
Strobel, James P. (Inventor); Moerk, John S. (Inventor); Youngquist, Robert C. (Inventor)
1996-01-01
An optical detector calibrator system simulates a source of optical radiation to which a detector to be calibrated is responsive. A light source selected to emit radiation in a range of wavelengths corresponding to the spectral signature of the source is disposed within a housing containing a microprocessor for controlling the light source and other system elements. An adjustable iris and a multiple aperture filter wheel are provided for controlling the intensity of radiation emitted from the housing by the light source to adjust the simulated distance between the light source and the detector to be calibrated. The geared iris has an aperture whose size is adjustable by means of a first stepper motor controlled by the microprocessor. The multiple aperture filter wheel contains neutral density filters of different attenuation levels which are selectively positioned in the path of the emitted radiation by a second stepper motor that is also controlled by the microprocessor. An operator can select a number of detector tests including range, maximum and minimum sensitivity, and basic functionality. During the range test, the geared iris and filter wheel are repeatedly adjusted by the microprocessor as necessary to simulate an incrementally increasing simulated source distance. A light source calibration subsystem is incorporated in the system which insures that the intensity of the light source is maintained at a constant level over time.
Global genetic capacity for mixotrophy in marine picocyanobacteria.
Yelton, Alexis P; Acinas, Silvia G; Sunagawa, Shinichi; Bork, Peer; Pedrós-Alió, Carlos; Chisholm, Sallie W
2016-12-01
The assimilation of organic nutrients by autotrophs, a form of mixotrophy, has been demonstrated in the globally abundant marine picocyanobacterial genera Prochlorococcus and Synechococcus. However, the range of compounds used and the distribution of organic compound uptake genes within picocyanobacteria are unknown. Here we analyze genomic and metagenomic data from around the world to determine the extent and distribution of mixotrophy in these phototrophs. Analysis of 49 Prochlorococcus and 18 Synechococcus isolate genomes reveals that all have the transporters necessary to take up amino acids, peptides and sugars. However, the number and type of transporters and associated catabolic genes differ between different phylogenetic groups, with low-light IV Prochlorococcus, and 5.1B, 5.2 and 5.3 Synechococcus strains having the largest number. Metagenomic data from 68 stations from the Tara Oceans expedition indicate that the genetic potential for mixotrophy in picocyanobacteria is globally distributed and differs between clades. Phylogenetic analyses indicate gradual organic nutrient transporter gene loss from the low-light IV to the high-light II Prochlorococcus. The phylogenetic differences in genetic capacity for mixotrophy, combined with the ubiquity of picocyanobacterial organic compound uptake genes suggests that mixotrophy has a more central role in picocyanobacterial ecology than was previously thought.
Properties of a CdZnO/ZnO multiple quantum-well light-emitting diode
NASA Astrophysics Data System (ADS)
Liu, Zhan-Hui; Zhang, Li-Li; Li, Qing-Fang; Zhang, Rong; Xie, Zi-Li; Xiu, Xiang-Qian; Liu, Bin
2016-10-01
A CdZnO/ZnO multiple quantum-well light-emitting diode (LED) structure was successfully grown by using plasma-assisted molecular beam epitaxy on a p-GaN template that had been grown by using metal-organic chemical-vapor deposition on a c-sapphire substrate. The properties of the sample were characterized by using high-resolution X-ray diffraction, transmission electron microscopy, and temperature-dependent photoluminescence measurements. The light output performance of the CdZnO/ZnO QW LED device was also investigated in detail by using I-V and electroluminescence spectral measurements. The characterization showed that our CdZnO/ZnO QW LED structure had good crystalline quality and weaker carrier localization. Owing to the heterojunction structure, the I-V curve indicated that the LED device had a higher turn-on voltage and series resistance. The EL measurement demonstrated that for our LED device's optoelectronic characteristic, the carrier-screening effect played the dominant role in the emission-energy blue-shift mechanism, and the broadening of the emission energy width was mainly ascribed to the band-filling effect. Without a special heat sinking, the L-I curve exhibited slight efficiency droop after 30 mA.
A combined approach for the evaluation of a volatile organic compound emissions inventory.
Choi, Yu-Jin; Calabrese, Richard V; Ehrman, Sheryl H; Dickerson, Russell R; Stehr, Jeffrey W
2006-02-01
Emissions inventories significantly affect photochemical air quality model performance and the development of effective control strategies. However, there have been very few studies to evaluate their accuracy. Here, to evaluate a volatile organic compound (VOC) emissions inventory, we implemented a combined approach: comparing the ratios of carbon bond (CB)-IV VOC groups to nitrogen oxides (NOx) or carbon monoxide (CO) using an emission preprocessing model, comparing the ratios of VOC source contributions from a source apportionment technique to NOx or CO, and comparing ratios of CB-IV VOC groups to NOx or CO and the absolute concentrations of CB-IV VOC groups using an air quality model, with the corresponding ratios and concentrations observed at three sites (Maryland, Washington, DC, and New Jersey). The comparisons of the ethene/NOx ratio, the xylene group (XYL)/NOx ratio, and ethene and XYL concentrations between estimates and measurements showed some differences, depending on the comparison approach, at the Maryland and Washington, DC sites. On the other hand, consistent results at the New Jersey site were observed, implying a possible overestimation of vehicle exhaust. However, in the case of the toluene group (TOL), which is emitted mainly from surface coating and printing sources in the solvent utilization category, the ratios of TOL/ NOx or CO, as well as the absolute concentrations revealed an overestimate of these solvent sources by a factor of 1.5 to 3 at all three sites. In addition, the overestimate of these solvent sources agreed with the comparisons of surface coating and printing source contributions relative to NOx from a source apportionment technique to the corresponding value of estimates at the Maryland site. Other studies have also suggested an overestimate of solvent sources, implying a possibility of inaccurate emission factors in estimating VOC emissions from surface coating and printing sources. We tested the impact of these overestimates with a chemical transport model and found little change in ozone but substantial changes in calculated secondary organic aerosol concentrations.
Pulse I-V characterization of a nano-crystalline oxide device with sub-gap density of states
NASA Astrophysics Data System (ADS)
Kim, Taeho; Hur, Ji-Hyun; Jeon, Sanghun
2016-05-01
Understanding the charge trapping nature of nano-crystalline oxide semiconductor thin film transistors (TFTs) is one of the most important requirements for their successful application. In our investigation, we employed a fast-pulsed I-V technique for understanding the charge trapping phenomenon and for characterizing the intrinsic device performance of an amorphous/nano-crystalline indium-hafnium-zinc-oxide semiconductor TFT with varying density of states in the bulk. Because of the negligible transient charging effect with a very short pulse, the source-to-drain current obtained with the fast-pulsed I-V measurement was higher than that measured by the direct-current characterization method. This is because the fast-pulsed I-V technique provides a charge-trap free environment, suggesting that it is a representative device characterization methodology of TFTs. In addition, a pulsed source-to-drain current versus time plot was used to quantify the dynamic trapping behavior. We found that the charge trapping phenomenon in amorphous/nano-crystalline indium-hafnium-zinc-oxide TFTs is attributable to the charging/discharging of sub-gap density of states in the bulk and is dictated by multiple trap-to-trap processes.
Pulse I-V characterization of a nano-crystalline oxide device with sub-gap density of states.
Kim, Taeho; Hur, Ji-Hyun; Jeon, Sanghun
2016-05-27
Understanding the charge trapping nature of nano-crystalline oxide semiconductor thin film transistors (TFTs) is one of the most important requirements for their successful application. In our investigation, we employed a fast-pulsed I-V technique for understanding the charge trapping phenomenon and for characterizing the intrinsic device performance of an amorphous/nano-crystalline indium-hafnium-zinc-oxide semiconductor TFT with varying density of states in the bulk. Because of the negligible transient charging effect with a very short pulse, the source-to-drain current obtained with the fast-pulsed I-V measurement was higher than that measured by the direct-current characterization method. This is because the fast-pulsed I-V technique provides a charge-trap free environment, suggesting that it is a representative device characterization methodology of TFTs. In addition, a pulsed source-to-drain current versus time plot was used to quantify the dynamic trapping behavior. We found that the charge trapping phenomenon in amorphous/nano-crystalline indium-hafnium-zinc-oxide TFTs is attributable to the charging/discharging of sub-gap density of states in the bulk and is dictated by multiple trap-to-trap processes.
A Mini-BAL Outflow at 900 pc from the Central Source: VLT/X-shooter Observations
NASA Astrophysics Data System (ADS)
Xu, Xinfeng; Arav, Nahum; Miller, Timothy; Benn, Chris
2018-05-01
We determine the physical conditions and location of the outflow material seen in the mini-BAL quasar SDSS J1111+1437 (z = 2.138). These results are based on the analysis of a high S/N, medium-resolution VLT/X-shooter spectrum. The main outflow component spans the velocity range ‑1500 to ‑3000 km s‑1 and has detected absorption troughs from both high-ionization species: C IV, N V, O VI, Si IV, P V, and S IV; and low-ionization species: H I, C II, Mg II, Al II, Al III, Si II, and Si III. Measurements of these troughs allow us to derive an accurate photoionization solution for this absorption component: a hydrogen column density, {log}({N}{{H}})={21.47}-0.27+0.21 cm‑2 and ionization parameter, {log}({U}{{H}})=-{1.23}-0.25+0.20. Troughs produced from the ground and excited states of S IV combined with the derived {U}{{H}} value allow us to determine an electron number density of {log}({n}{{e}})={3.62}-0.11+0.09 cm‑3 and to obtain the distance of the ionized gas from the central source: R={880}-260+210 pc.
Superluminal Emission Processes as a Key to Understanding Pulsar Radiation
NASA Astrophysics Data System (ADS)
Schmidt, Andrea; Ardavan, H.; Fasel, J., III; Perez, M.; Singleton, J.
2007-12-01
Theoretical and experimental work has established that polarization currents can be animated to travel faster than the speed of light in vacuo and that these superluminal distribution patterns emit tightly focused packets of electromagnetic radiation that differ fundamentally from the emission generated by any other known radiation source. Since 2004, a small team at Los Alamos National Laboratory has, in collaboration with UK universities, conducted analytical, computational and practical studies of radiation sources that exceed the speed of light. Numerical evaluations of the Liénard-Wiechert field generated by such sources show that superluminal emission has the following intrinsic characteristics: (i) It is sharply focused along a rigidly rotating spiral-shaped beam that embodies the cusp of the envelope of the emitted wave fronts. (ii) It consists of either one or three concurrent polarization modes that constitute contributions to the field from differing retarded times. (iii) Two of the modes are comparable in strength at both edges of the signal and dominate over the third everywhere except in the middle of the pulse. (iv) The position angles of each of its dominant modes, as well as that of the total field, swing across the beam by as much as 180 degrees and remain approximately orthogonal throughout their excursion across the beam. (v) One of the three modes is highly circularly polarized and differs in its sense of polarization from the other two. (vi) Two of the modes have a very high degree of linear polarization across the entire pulse. Given the fundamental nature of the Liénard-Wiechert field, the coincidence of these characteristics with those of the radio emission received from pulsars is striking, especially coupled with the experimentally demonstrated fact that the radiation intensity on the cusp decays as 1/R instead of 1/R^2 and is therefore intrinsically bright.
Xu, P; Zhao, L N; Lv, X J; Lu, J; Yuan, Y; Zhao, G; Zhu, S N
2009-06-08
1W quasi-white-light source has been generated from a single lithium tantalate with cascaded domain modulation. The quasi-white-light is combined by proper proportion of the red, green and blue laser light. The red and the blue result from a compact self-sum frequency optical parametric oscillation when pumped by a single green laser. The efficiency of quasi-white-light from the green pump reaches 27%. This compact design can be employed not only as a stable and powerful RGB light source but also an effective blue laser generator.
Single-molecule study of DNA unlinking by eukaryotic and prokaryotic type-II topoisomerases
Charvin, G.; Bensimon, D.; Croquette, V.
2003-01-01
Type-II topoisomerases are responsible for untangling DNA during replication by removing supercoiled and interlinked DNA structures. Using a single-molecule micromanipulation setup, we follow the real-time decatenation of two mechanically braided DNA molecules by Drosophila melanogaster topoisomerase (Topo) II and Escherichia coli Topo IV. Although Topo II relaxes left-handed (L) and right-handed (R-) braids similarly at a rate of ≈2.9 s–1, Topo IV has a marked preference for L-braids, which it relaxes completely and processively at a rate of ≈2.4 s–1. However, Topo IV can unlink R-braids at about half that rate when they supercoil to form L-plectonemes. These results imply that the preferred substrate for unlinking by Topo IV has the symmetry of an L-crossing and shed new light on the decatenation of daughter strands during DNA replication, which are usually assumed to be linked in an R-braid. PMID:12902541
Electron transport characteristics of silicon nanowires by metal-assisted chemical etching
NASA Astrophysics Data System (ADS)
Qi, Yangyang; Wang, Zhen; Zhang, Mingliang; Wang, Xiaodong; Ji, An; Yang, Fuhua
2014-03-01
The electron transport characteristics of silicon nanowires (SiNWs) fabricated by metal-assisted chemical etching with different doping concentrations were studied. By increasing the doping concentration of the starting Si wafer, the resulting SiNWs were prone to have a rough surface, which had important effects on the contact and the electron transport. A metal-semiconductor-metal model and a thermionic field emission theory were used to analyse the current-voltage (I-V) characteristics. Asymmetric, rectifying and symmetric I-V curves were obtained. The diversity of the I-V curves originated from the different barrier heights at the two sides of the SiNWs. For heavily doped SiNWs, the critical voltage was one order of magnitude larger than that of the lightly doped, and the resistance obtained by differentiating the I-V curves at large bias was also higher. These were attributed to the lower electron tunnelling possibility and higher contact barrier, due to the rough surface and the reduced doping concentration during the etching process.
Ghost imaging with bucket detection and point detection
NASA Astrophysics Data System (ADS)
Zhang, De-Jian; Yin, Rao; Wang, Tong-Biao; Liao, Qing-Hua; Li, Hong-Guo; Liao, Qinghong; Liu, Jiang-Tao
2018-04-01
We experimentally investigate ghost imaging with bucket detection and point detection in which three types of illuminating sources are applied: (a) pseudo-thermal light source; (b) amplitude modulated true thermal light source; (c) amplitude modulated laser source. Experimental results show that the quality of ghost images reconstructed with true thermal light or laser beam is insensitive to the usage of bucket or point detector, however, the quality of ghost images reconstructed with pseudo-thermal light in bucket detector case is better than that in point detector case. Our theoretical analysis shows that the reason for this is due to the first order transverse coherence of the illuminating source.
Risky Business II: Finding Big Bucks. Panel IV.
ERIC Educational Resources Information Center
Appalachia, 1986
1986-01-01
Five panelists discuss alternatives to venture capital sources for Appalachian business expansion, new institutions created or supported by state and local governments to provide capital, and how businesses can best position themselves to take advantage of all capital sources. (NEC)
Potential Sources of Polarized Light from a Plant Canopy
NASA Technical Reports Server (NTRS)
Vanderbilt, Vern; Daughtry, Craig; Dahlgren, Robert
2016-01-01
Field measurements have demonstrated that sunlight polarized during a first surface reflection by shiny leaves dominates the optical polarization of the light reflected by shiny-leafed plant canopies having approximately spherical leaf angle probability density functions ("Leaf Angle Distributions" - LAD). Yet for other canopies - specifically those without shiny leaves and/or spherical LADs - potential sources of optically polarized light may not always be obvious. Here we identify possible sources of polarized light within those other canopies and speculate on the ecologically important information polarization measurements of those sources might contain.
Lack of promoter IV-driven BDNF transcription results in depression-like behavior.
Sakata, K; Jin, L; Jha, S
2010-10-01
Transcription of Bdnf is controlled by multiple promoters, in which promoter IV contributes significantly to activity-dependent Bdnf transcription. We have generated promoter IV mutant mice [brain-derived neurotrophic factor (BDNF)-KIV] in which promoter IV-driven expression of BDNF is selectively disrupted by inserting a green fluorescent protein (GFP)-STOP cassette within the Bdnf exon IV locus. BDNF-KIV animals exhibited depression-like behavior as shown by the tail suspension test (TST), sucrose preference test (SPT) and learned helplessness test (LHT). In addition, BDNF-KIV mice showed reduced activity in the open field test (OFT) and reduced food intake in the novelty-suppressed feeding test (NSFT). The mutant mice did not display anxiety-like behavior in the light and dark box test and elevated plus maze tests. Interestingly, the mutant mice showed defective response inhibition in the passive avoidance test (PAT) even though their learning ability was intact when measured with the active avoidance test (AAT). These results suggest that promoter IV-dependent BDNF expression plays a critical role in the control of mood-related behaviors. This is the first study that directly addressed the effects of endogenous promoter-driven expression of BDNF in depression-like behavior. © 2010 The Authors. Genes, Brain and Behavior © 2010 Blackwell Publishing Ltd and International Behavioural and Neural Genetics Society.
Grossman, M.W.; George, W.A.; Pai, R.Y.
1985-08-13
A technique is disclosed for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support. 6 figs.
Synchrotron Light Sources in Developing Countries
NASA Astrophysics Data System (ADS)
Winick, Herman; Pianetta, Piero
2017-01-01
The more than 50 light sources now in operation around the world include facilities in Brazil, Korea, and Taiwan which started their programs in the 1980's when they were developing countries. They came on line in the 1990's and have since trained hundreds of graduate students locally, without sending them abroad and losing many of them. They have also attracted dozens of mid-career diaspora scientists to return. Their growing user communities have demanded more advanced facilities, leading to the funding of higher performance new light sources that are now coming into operation. Light sources in the developing world now include the following: SESAME in the Middle East which is scheduled to start research in 2017 (www.sesame.org); The African Light Source, in the planning stage (www.africanlightsource.org); and The Mexican Light Source, in the planning stage (http://www.aps.org/units/fip/newsletters/201509/mexico.cfm). See: http://wpj.sagepub.com/content/32/4/92.full.pdf +html; http://www.lightsources.org/press-release/2015/11/20/grenoble-resolutions-mark-historical-step-towards-african-light-source. SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515.
Schlieren with a laser diode source
NASA Technical Reports Server (NTRS)
Burner, A. W.; Franke, J. M.
1981-01-01
The use of a laser diode as a light source for a schlieren system designed to study phase objects such as a wind-tunnel flow is explored. A laser diode schlieren photograph and a white light schlieren photograph (zirconium arc source) are presented for comparison. The laser diode has increased sensitivity, compared with light schlieren, without appreciable image degradiation, and is an acceptable source for schlieren flow visualization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.
2014-08-30
This document analyzes the optical, material, and photobiological hazards of LED light sources compared to conventional light sources. It documents that LEDs generally produce the same amount of blue light, which is the primary contributor to the risks, as other sources at the same CCT. Duv may have some effect on the amount of blue light, but CRI does not.
Impact of red versus blue light on tolerability and efficacy of PDT: a randomized controlled trial.
Gholam, Patrick; Bosselmann, Ina; Enk, Alexander; Fink, Christine
2018-06-01
Various light sources may be used for photodynamic therapy of actinic keratosis since photosensitizing agents are activated by different wavelengths. However, the relative impact of red and blue light irradiation on the efficacy and tolerability of therapy is controversial. The aim of this study is to compare the efficacy and tolerability of therapy with red versus blue light sources, as well as the patients' evaluation of cosmetic results, clinical response, painfulness and preferred light source for future photodynamic treatments. This is a prospective, single-center, randomized, controlled, open-label study with 28 patients undergoing elective photodynamic therapy. Red and blue light sources both showed very good results with a complete response rate of 84 % and 85 % respectively. Pain during photodynamic therapy was 6.1 vs. 5.4 (and 2.1 vs. 1.5 eight hours after therapy) on the visual analogue scale. Although these differences were statistically significant, the clinical relevance is low, since the number of therapy interruptions were equally distributed in both groups, and patients' subjective evaluation of the treatment showed no personal preference towards the light sources. Both light sources showed very good clinical results and satisfactory tolerability in this study. © 2018 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.
Superluminescent light emitting diodes: the best out of two worlds
NASA Astrophysics Data System (ADS)
Rossetti, M.; Napierala, J.; Matuschek, N.; Achatz, U.; Duelk, M.; Vélez, C.; Castiglia, A.; Grandjean, N.; Dorsaz, J.; Feltin, E.
2012-03-01
Since pico-projectors were starting to become the next electronic "must-have" gadget, the experts were discussing which light-source technology seems to be the best for the existing three major projection approaches for the optical scanning module such as digital light processing, liquid crystal on silica and laser beam steering. Both so-far used light source technologies have distinct advantages and disadvantages. Though laser-based pico-projectors are focus-free and deliver a wider color gamut, their major disadvantages are speckle noise, cost and safety issues. In contrast, projectors based on cheaper Light Emitting Diodes (LEDs) as light source are criticized for a lack of brightness and for having limited focus. Superluminescent Light Emitting Diodes (SLEDs) are temporally incoherent and spatially coherent light sources merging in one technology the advantages of both Laser Diodes (LDs) and LEDs. With almost no visible speckle noise, focus-free operation and potentially the same color gamut than LDs, SLEDs could potentially answer the question which light source to use in future projector applications. In this quest for the best light source, we realized visible SLEDs emitting both in the red and blue spectral region. While the technology required for the realization of red emitters is already well established, III-nitride compounds required for blue emission have experienced a major development only in relatively recent times and the technology is still under development. The present paper is a review of the status of development reached for the blue superluminescent diodes based on the GaN material system.
Integrated LED-based luminaire for general lighting
Dowling, Kevin J.; Lys, Ihor A.; Williamson, Ryan C.; Roberge, Brian; Roberts, Ron; Morgan, Frederick; Datta, Michael Jay; Mollnow, Tomas Jonathan
2016-08-30
Lighting apparatus and methods employing LED light sources are described. The LED light sources are integrated with other components in the form of a luminaire or other general purpose lighting structure. Some of the lighting structures are formed as Parabolic Aluminum Reflector (PAR) luminaires, allowing them to be inserted into conventional sockets. The lighting structures display beneficial operating characteristics, such as efficient operation, high thermal dissipation, high output, and good color mixing.
Integrated LED-based luminare for general lighting
Dowling, Kevin J.; Lys, Ihor A.; Roberge, Brian; Williamson, Ryan C.; Roberts, Ron; Datta, Michael; Mollnow, Tomas; Morgan, Frederick M.
2013-03-05
Lighting apparatus and methods employing LED light sources are described. The LED light sources are integrated with other components in the form of a luminaire or other general purpose lighting structure. Some of the lighting structures are formed as Parabolic Aluminum Reflector (PAR) luminaires, allowing them to be inserted into conventional sockets. The lighting structures display beneficial operating characteristics, such as efficient operation, high thermal dissipation, high output, and good color mixing.
Northern Red Oak Seedling Growth Varies by Light Intensity and Seed Source
Charles E. McGee
1968-01-01
Northern red oak seedlings from each of three seed sources were subjected for one growing season to one of four intensities of light: full light, 70 percent light, 37 percent light, and 8 percent light. Seedlings grown in the open were taller than those grown in the shade and had more, generally heavier leaves. Height and leaf growth decreased as the amount of light...
NASA Astrophysics Data System (ADS)
Gyoneva, Lazarina
The glomerular basement membrane (GBM) is a vital part of the blood-urine filtration barrier in the kidneys. In healthy GBMs, the main tension-resisting component is alpha3(IV)alpha4(IV)alpha5(IV) type IV collagen, but in some diseases it is replaced by other collagen IV isoforms. As a result, the GBM becomes leaky and disorganized, ultimately resulting in kidney failure. Our goal is to understanding the biomechanical aspects of the alpha3(IV)alpha4(IV)alpha5(IV) chains and how their absence could be responsible for (1) the initial injury to the GBM and (2) progression to kidney failure. A combination of experiments and computational models were designed for that purpose. A model basement membrane was used to compare experimentally the distensibility of tissues with the alpha3(IV)alpha4(IV)alpha5(IV) chains present and missing. The experiments showed basement membranes containing alpha3(IV)alpha4(IV)alpha5(IV) chains were less distensible. It has been postulated that the higher level of lateral cross-linking (supercoiling) in the alpha3(IV)alpha4(IV)alpha5(IV) networks contributes additional strength/stability to basement membranes. In a computational model of supercoiled networks, we found that supercoiling greatly increased the stiffness of collagen IV networks but only minimally decreased the permeability, which is well suited for the needs of the GBM. It is also known that the alpha3(IV)alpha4(IV)alpha5(IV) networks are more protected from enzymatic degradation, and we explored their significance in GBM remodeling. Our simulations showed that the more protected network was needed to prevent the system from entering a dangerous feedback cycle due to autoregulation mechanisms in the kidneys. Overall, the work adds to the evidence of biomechanical differences between the alpha3(IV)alpha4(IV)alpha5(IV) networks and other collagen IV networks, points to supercoiling as the main source of biomechanical differences, discusses the suitability of alpha3(IV)alpha4(IV)alpha5(IV) networks to meet the mechanics and permeability needs of the GBM, and explores the role of biomechanics and enzymatic digestion in GBM remodeling.
The Endockscope Using Next Generation Smartphones: "A Global Opportunity".
Tse, Christina; Patel, Roshan M; Yoon, Renai; Okhunov, Zhamshid; Landman, Jaime; Clayman, Ralph V
2018-06-02
The Endockscope combines a smartphone, a battery powered flashlight and a fiberoptic cystoscope allowing for mobile videocystoscopy. We compared conventional videocystoscopy to the Endockscope paired with next generation smartphones in an ex-vivo porcine bladder model to evaluate its image quality. The Endockscope consists of a three-dimensional (3D) printed attachment that connects a smartphone to a flexible fiberoptic cystoscope plus a 1000 lumen light-emitting diode (LED) cordless light source. Video recordings of porcine cystoscopy with a fiberoptic flexible cystoscope (Storz) were captured for each mobile device (iPhone 6, iPhone 6S, iPhone 7, Samsung S8, and Google Pixel) and for the high-definition H3-Z versatile camera (HD) set-up with both the LED light source and the xenon light (XL) source. Eleven faculty urologists, blinded to the modality used, evaluated each video for image quality/resolution, brightness, color quality, sharpness, overall quality, and acceptability for diagnostic use. When comparing the Endockscope coupled to an Galaxy S8, iPhone 7, and iPhone 6S with the LED portable light source to the HD camera with XL, there were no statistically significant differences in any metric. 82% and 55% of evaluators considered the iPhone 7 + LED light source and iPhone 6S + LED light, respectively, appropriate for diagnostic purposes as compared to 100% who considered the HD camera with XL appropriate. The iPhone 6 and Google Pixel coupled with the LED source were both inferior to the HD camera with XL in all metrics. The Endockscope system with a LED light source when coupled with either an iPhone 7 or Samsung S8 (total cost: $750) is comparable to conventional videocystoscopy with a standard camera and XL light source (total cost: $45,000).
Effects of source shape on the numerical aperture factor with a geometrical-optics model.
Wan, Der-Shen; Schmit, Joanna; Novak, Erik
2004-04-01
We study the effects of an extended light source on the calibration of an interference microscope, also referred to as an optical profiler. Theoretical and experimental numerical aperture (NA) factors for circular and linear light sources along with collimated laser illumination demonstrate that the shape of the light source or effective aperture cone is critical for a correct NA factor calculation. In practice, more-accurate results for the NA factor are obtained when a linear approximation to the filament light source shape is used in a geometric model. We show that previously measured and derived NA factors show some discrepancies because a circular rather than linear approximation to the filament source was used in the modeling.
Opacity meter for monitoring exhaust emissions from non-stationary sources
Dec, John Edward
2000-01-01
Method and apparatus for determining the opacity of exhaust plumes from moving emissions sources. In operation, a light source is activated at a time prior to the arrival of a diesel locomotive at a measurement point, by means of a track trigger switch or the Automatic Equipment Identification system, such that the opacity measurement is synchronized with the passage of an exhaust plume past the measurement point. A beam of light from the light source passes through the exhaust plume of the locomotive and is detected by a suitable detector, preferably a high-rate photodiode. The light beam is well-collimated and is preferably monochromatic, permitting the use of a narrowband pass filter to discriminate against background light. In order to span a double railroad track and provide a beam which is substantially stronger than background, the light source, preferably a diode laser, must provide a locally intense beam. A high intensity light source is also desirable in order to increase accuracy at the high sampling rates required. Also included is a computer control system useful for data acquisition, manipulation, storage and transmission of opacity data and the identification of the associated diesel engine to a central data collection center.
NASA Astrophysics Data System (ADS)
Liu, Jianguo; Yan, Wen; Chen, Zhong; Lu, Jun
2012-09-01
Clay minerals of surface sediment samples from nine bays/harbors along northern coast of the South China Sea (SCS) are used for sediment sources and contribution estimation in the study areas. Results reveal that sediments in the study bays/harbors seem to be a mixture of sediments from the Pearl, Hanjiang River and local islands/rivers, but their clay mineral assemblage is distinct from that of Luzon and Taiwan sediments, indicating that sediments are derived mainly from the neighboring sources through riverine input and partly from localized sediments. Due to input of local sediments in the northern SCS, sediments from both east of the Leizhou Peninsula (Area IV) and next to the Pearl River estuary (PRE, Area II) have high smectite percent. Affected by riverine input of the Pearl and Hanjiang Rivers, sediments in west of the PRE (Area III) and east of the PRE (Area I) have high illite (average 47%) and kaolinite (54%) percents, respectively. Sediment contributions of various major sources to the study areas are estimated as the following: (1) the Hanjiang River provide 95% and 84% sediments in Areas I and II, respectively, (2) the Pearl River supply 79% and 29% sediments in Areas III and IV, respectively and (3) local sediments contribute the rest and reach the maximum (˜71%) in Area IV.
Thumb-actuated two-axis controller
NASA Technical Reports Server (NTRS)
Hollow, R. H. (Inventor)
1986-01-01
A two axis joystick controller is described. It produces at least one output signal in relation to pivotal displacement of a member with respect to an intersection of the two axes. The member is pivotally movable on a support with respect to the two axes. The support has a centrally disposed aperture. A light source is mounted on the pivotally movable member above the aperture to direct light through the aperture. A light sensor is mounted below the aperture in the support at the intersection of the two axes to receive the light from the light source directed through the aperture. The light sensor produces at least one output signal related to a location on the sensor at which the light from the light source strikes the sensor.
Uranium(IV) adsorption by natural organic matter in anoxic sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bone, Sharon E.; Dynes, James J.; Cliff, John
2017-01-09
Uranium is an important fuel source and a global environmental contaminant. It accumulates in the tetravalent state, U(IV), in anoxic sediments, including ore deposits, marine basins, and contaminated aquifers. However, very little is known about the speciation of U(IV) in low temperature geochemical environments, inhibiting the development of a conceptual model of U behavior. Until recently, U(IV) was assumed to exist predominantly as the sparingly soluble mineral uraninite (UO 2) in anoxic sediments; yet studies now show that UO 2 is not often dominant in these environments. However, a model of U(IV) speciation under environmentally relevant conditions has not yetmore » been developed. Here we show that complexes of U(IV) adsorb on organic carbon and organic carbon-coated clays in an organic-rich natural substrate under field-relevant conditions. Whereas previous research assumed that the U(IV) product depended on the reduction pathway, our results demonstrate that UO 2 formation can be inhibited simply by decreasing the U:solid ratio. Thus, it is the number and type of surface ligands that controls U(IV) speciation subsequent to U(VI) reduction. Projections of U transport and bioavailability, and thus its threat to human and ecosystem health, must consider retention of U(IV) ions within the local sediment environment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tong, Tao; Letoquin, Ronan; Keller, Bernd
An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and a remote planar phosphor carrier having at least one conversion material. The phosphor carrier can be remote to the light sources and mounted to the heat sink so that heat from the phosphor carrier spreads into the heat sink. The phosphor carrier can comprise a thermally conductive transparent material and a phosphor layer, with an LED based light source mounted to the heat sink such that light from the light source passes through the phosphor carrier. At least some of the LED lightmore » is converted by the phosphor carrier, with some lamp embodiments emitting a white light combination of LED and phosphor light. The phosphor arranged according to the present invention can operate at lower temperature to thereby operate at greater phosphor conversion efficiency and with reduced heat related damage to the phosphor.« less
In situ calibration of a light source in a sensor device
Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.
2015-12-29
A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.
Rebec, Katja Malovrh; Klanjšek-Gunde, Marta; Bizjak, Grega; Kobav, Matej B
2015-01-01
Ergonomic science at work and living places should appraise human factors concerning the photobiological effects of lighting. Thorough knowledge on this subject has been gained in the past; however, few attempts have been made to propose suitable evaluation parameters. The blue light hazard and its influence on melatonin secretion in age-dependent observers is considered in this paper and parameters for its evaluation are proposed. New parameters were applied to analyse the effects of white light-emitting diode (LED) light sources and to compare them with the currently applied light sources. The photobiological effects of light sources with the same illuminance but different spectral power distribution were determined for healthy 4-76-year-old observers. The suitability of new parameters is discussed. Correlated colour temperature, the only parameter currently used to assess photobiological effects, is evaluated and compared to new parameters.
NASA Technical Reports Server (NTRS)
Juday, Richard D. (Inventor)
1998-01-01
An apparatus is disclosed for reading and/or writing information or to from an optical recording medium having a plurality of information storage layers. The apparatus includes a dynamic holographic optical element configured to focus light on the optical recording medium. a control circuit arranged to supply a drive signal to the holographic optical element, and a storage device in communication with the control circuit and storing at least a first drive signal and a second drive signal. The holographic optical element focusses light on a first one of the plurality of information storage layers when driven by the first drive signal on a second one of the plurality of information storage layers when driven by the second drive signal. An optical switch is also disclosed for connecting at least one light source in a source array to at least one light receiver in a receiver array. The switch includes a dynamic holographic optical element configured to receive light from the source array and to transmit light to the receiver array, a control circuit arranged to supply a drive signal to the holographic optical element, and a storage device in communication with the control circuit and storing at least a first drive signal and a second drive signal. The holographic optical element connects a first light source in the source array to a first light receiver in the receiver array when driven by the first drive signal and the holographic optical element connects the first light source with the first light receiver and a second light receiver when driven by the second drive signal.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
1998-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Reflector system for a lighting fixture
Siminovitch, Michael J.; Page, Erik; Gould, Carl T.
2001-01-01
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope.
Lin, Yiqun; Wan, Brandi; Belanger, Claudia; Hecker, Kent; Gilfoyle, Elaine; Davidson, Jennifer; Cheng, Adam
2017-01-01
The depth of chest compression (CC) during cardiac arrest is associated with patient survival and good neurological outcomes. Previous studies showed that mattress compression can alter the amount of CCs given with adequate depth. We aim to quantify the amount of mattress compressibility on two types of ICU mattresses and explore the effect of memory foam mattress use and a backboard on mattress compression depth and effect of feedback source on effective compression depth. The study utilizes a cross-sectional self-control study design. Participants working in the pediatric intensive care unit (PICU) performed 1 min of CC on a manikin in each of the following four conditions: (i) typical ICU mattress; (ii) typical ICU mattress with a CPR backboard; (iii) memory foam ICU mattress; and (iv) memory foam ICU mattress with a CPR backboard, using two different sources of real-time feedback: (a) external accelerometer sensor device measuring total compression depth and (b) internal light sensor measuring effective compression depth only. CPR quality was concurrently measured by these two devices. The differences of the two measures (mattress compression depth) were summarized and compared using multilevel linear regression models. Effective compression depths with different sources of feedback were compared with a multilevel linear regression model. The mean mattress compression depth varied from 24.6 to 47.7 mm, with percentage of depletion from 31.2 to 47.5%. Both use of memory foam mattress (mean difference, MD 11.7 mm, 95%CI 4.8-18.5 mm) and use of backboard (MD 11.6 mm, 95% CI 9.0-14.3 mm) significantly minimized the mattress compressibility. Use of internal light sensor as source of feedback improved effective CC depth by 7-14 mm, compared with external accelerometer sensor. Use of a memory foam mattress and CPR backboard minimizes mattress compressibility, but depletion of compression depth is still substantial. A feedback device measuring sternum-to-spine displacement can significantly improve effective compression depth on a mattress. Not applicable. This is a mannequin-based simulation research.
Code of Federal Regulations, 2011 CFR
2011-01-01
... and design; (iii) Details of the method of incorporation and binding of the plutonium in the source; (iv) Procedures for and results of prototype testing of sources, which are designed to contain more... experimental studies and tests, required by the Commission to facilitate a determination of the safety of the...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 11 2011-07-01 2011-07-01 false PET and polystyrene affected sources...: Group IV Polymers and Resins § 63.1318 PET and polystyrene affected sources—testing and compliance... not apply and owners or operators are not required to comply with § 63.113. (b) PET affected sources...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 12 2012-07-01 2011-07-01 true PET and polystyrene affected sources...: Group IV Polymers and Resins § 63.1318 PET and polystyrene affected sources—testing and compliance... not apply and owners or operators are not required to comply with § 63.113. (b) PET affected sources...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 11 2010-07-01 2010-07-01 true PET and polystyrene affected sources...: Group IV Polymers and Resins § 63.1318 PET and polystyrene affected sources—testing and compliance... not apply and owners or operators are not required to comply with § 63.113. (b) PET affected sources...
Electrical source of pseudothermal light
NASA Astrophysics Data System (ADS)
Kuusela, Tom A.
2018-06-01
We describe a simple and compact electrical version of a pseudothermal light source. The source is based on electrical white noise whose spectral properties are tailored by analog filters. This signal is used to drive a light-emitting diode. The type of second-order coherence of the output light can be either Gaussian or Lorentzian, and the intensity distribution can be either Gaussian or non-Gaussian. The output light field is similar in all viewing angles, and thus, there is no need for a small aperture or optical fiber in temporal coherence analysis.
Sources of background light on space based laser communications links
NASA Astrophysics Data System (ADS)
Farrell, Thomas C.
2018-05-01
We discuss the sources and levels of background light that should be expected on space based laser communication (lasercom) crosslinks and uplinks, as well as on downlinks to ground stations. The analyses are valid for both Earth orbiting satellites and inter-planetary links. Fundamental equations are derived suitable for first order system engineering analyses of potential lasercom systems. These divide sources of background light into two general categories: extended sources which fill the field of view of a receiver's optics, and point sources which cannot be resolved by the optics. Specific sources of background light are discussed, and expected power levels are estimated. For uplinks, reflected sunlight and blackbody radiation from the Earth dominates. For crosslinks, depending on specific link geometry, sources of background light may include the Sun in the field of view (FOV), reflected sunlight and blackbody radiation from planets and other bodies in the solar system, individual bright stars in the FOV, the amalgam of dim stars in the FOV, zodiacal light, and reflected sunlight off of the transmitting spacecraft. For downlinks, all of these potentially come into play, and the effects of the atmosphere, including turbulence, scattering, and absorption contribute as well. Methods for accounting for each of these are presented. Specific examples are presented to illustrate the relative contributions of each source for various link geometries.
10 CFR 50.48 - Fire protection.
Code of Federal Regulations, 2011 CFR
2011-01-01
... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...
10 CFR 50.48 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-01-01
... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
..., Emeryville, CA 94608. Wenzhou Huir Electric Science & Technology Co. Ltd., Bridge East Wan- Ao, Qiatou... notice to the respondent, to find the facts to be as alleged in the complaint and this notice and to...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., as where a layer of paint or dense chemical residue blocks all incoming light); this term does not... of American Railroads. Unqualified Retroreflective Sheeting means engineering grade sheeting, super engineering grade sheeting (enclosed lens) or high-intensity type sheeting (ASTM Type I, II, III, or IV...
Noncoherent light for PDT of spontaneous animal tumors
NASA Astrophysics Data System (ADS)
Lucroy, Michael D.; Ridgway, Tisha D.; Higbee, Russell G.; Reeds, Kimberly
2004-07-01
Cultured 9L cells were incubated with graded doses of pheophorbide-a-hexyl ether (HPPH) and exposed to 665 nm red light from either a noncoherent light source or a KTP-pumped dye laser. Cell death was observed after irradiation using either light source, with the noncoherent light being most effective at the highest HPPH concentrations. To determing the practicality of using the noncoherent light source for clinical PDT, dogs and cats with spontaneous tumors were injected intravenously with 0.15 mg/kg HPPH one hour before their tumors were irradiated with 665 nm noncoherent light (50 mW cm-2, 100 J cm-2). Of the 9 tumors treated, 8 complete responses were observed, all of which occurred in animals with squamous cell carcinoma. After 68 weeks of follow up, the median initial disease free interval had not been reached. These data support the use of noncoherent light sources for PDT of spontaneous tumors in animals, representing a cost-effective alternative to medical lasers in both veterinary and human dermatology and oncology.
NASA Astrophysics Data System (ADS)
Hosseini, S. A.; Zangian, M.; Aghabozorgi, S.
2018-03-01
In the present paper, the light output distribution due to poly-energetic neutron/gamma (neutron or gamma) source was calculated using the developed MCNPX-ESUT-PE (MCNPX-Energy engineering of Sharif University of Technology-Poly Energetic version) computational code. The simulation of light output distribution includes the modeling of the particle transport, the calculation of scintillation photons induced by charged particles, simulation of the scintillation photon transport and considering the light resolution obtained from the experiment. The developed computational code is able to simulate the light output distribution due to any neutron/gamma source. In the experimental step of the present study, the neutron-gamma discrimination based on the light output distribution was performed using the zero crossing method. As a case study, 241Am-9Be source was considered and the simulated and measured neutron/gamma light output distributions were compared. There is an acceptable agreement between the discriminated neutron/gamma light output distributions obtained from the simulation and experiment.
Evaluation of light detector surface area for functional Near Infrared Spectroscopy.
Wang, Lei; Ayaz, Hasan; Izzetoglu, Meltem; Onaral, Banu
2017-10-01
Functional Near Infrared Spectroscopy (fNIRS) is an emerging neuroimaging technique that utilizes near infrared light to detect cortical concentration changes of oxy-hemoglobin and deoxy-hemoglobin non-invasively. Using light sources and detectors over the scalp, multi-wavelength light intensities are recorded as time series and converted to concentration changes of hemoglobin via modified Beer-Lambert law. Here, we describe a potential source for systematic error in the calculation of hemoglobin changes and light intensity measurements. Previous system characterization and analysis studies looked into various fNIRS parameters such as type of light source, number and selection of wavelengths, distance between light source and detector. In this study, we have analyzed the contribution of light detector surface area to the overall outcome. Results from Monte Carlo based digital phantoms indicated that selection of detector area is a critical system parameter in minimizing the error in concentration calculations. The findings here can guide the design of future fNIRS sensors. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Linac Coherent Light Source
White, William E.; Robert, Aymeric; Dunne, Mike
2015-05-01
The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.
21 CFR 352.71 - Light source (solar simulator).
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Light source (solar simulator). 352.71 Section 352... Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a... nanometers. In addition, a solar simulator should have no significant time-related fluctuations in radiation...
21 CFR 352.71 - Light source (solar simulator).
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Light source (solar simulator). 352.71 Section 352... Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a... nanometers. In addition, a solar simulator should have no significant time-related fluctuations in radiation...
21 CFR 352.71 - Light source (solar simulator).
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Light source (solar simulator). 352.71 Section 352... Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a... of its total energy output contributed by nonsolar wavelengths shorter than 290 nanometers; and it...
21 CFR 352.71 - Light source (solar simulator).
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Light source (solar simulator). 352.71 Section 352.71 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a...
21 CFR 352.71 - Light source (solar simulator).
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Light source (solar simulator). 352.71 Section 352.71 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Procedures § 352.71 Light source (solar simulator). A solar simulator used for determining the SPF of a...
Tuning the reactivity of mononuclear nonheme manganese(iv)-oxo complexes by triflic acid
Chen, Junying; Yoon, Heejung; Lee, Yong -Min; ...
2015-04-14
Triflic acid (HOTf)-bound nonheme Mn( IV)-oxo complexes, [(L)Mn IV(O)] 2+–(HOTf) 2 (L = N4Py and Bn-TPEN; N4Py = N,N-bis(2-pyridylmethyl)-N-bis(2-pyridyl)methylamine and Bn-TPEN = N-benzyl-N,N',N'-tris(2-pyridylmethyl)ethane-1,2-diamine), were synthesized by adding HOTf to the solutions of the [(L)Mn IV(O)] 2+ complexes and were characterized by various spectroscopies. The one-electron reduction potentials of the Mn IV(O) complexes exhibited a significant positive shift upon binding of HOTf. The driving force dependences of electron transfer (ET) from electron donors to the Mn IV(O) and Mn IV(O)–(HOTf) 2 complexes were examined and evaluated in light of the Marcus theory of ET to determine the reorganization energies of ET.more » The smaller reorganization energies and much more positive reduction potentials of the [(L)Mn IV(O)] 2+–(HOTf) 2 complexes resulted in greatly enhanced oxidation capacity towards one-electron reductants and para-X-substituted-thioanisoles. The reactivities of the Mn(IV)-oxo complexes were markedly enhanced by binding of HOTf, such as a 6.4 × 10 5-fold increase in the oxygen atom transfer (OAT) reaction (i.e., sulfoxidation). Such a remarkable acceleration in the OAT reaction results from the enhancement of ET from para-X-substituted-thioanisoles to the MnIV(O) complexes as revealed by the unified ET driving force dependence of the rate constants of OAT and ET reactions of [(L)Mn IV(O)] 2+–(HOTf) 2. In contrast, deceleration was observed in the rate of H-atom transfer (HAT) reaction of [(L)Mn IV(O)] 2+–(HOTf) 2 complexes with 1,4-cyclohexadiene as compared with those of the [(L)Mn IV(O)] 2+ complexes. Thus, the binding of two HOTf molecules to the Mn IV(O) moiety resulted in remarkable acceleration of the ET rate when the ET is thermodynamically feasible. When the ET reaction is highly endergonic, the rate of the HAT reaction is decelerated due to the steric effect of the counter anion of HOTf.« less
NASA Astrophysics Data System (ADS)
Gall, C.; Stritzinger, M. D.; Ashall, C.; Baron, E.; Burns, C. R.; Hoeflich, P.; Hsiao, E. Y.; Mazzali, P. A.; Phillips, M. M.; Filippenko, A. V.; Anderson, J. P.; Benetti, S.; Brown, P. J.; Campillay, A.; Challis, P.; Contreras, C.; Elias de la Rosa, N.; Folatelli, G.; Foley, R. J.; Fraser, M.; Holmbo, S.; Marion, G. H.; Morrell, N.; Pan, Y.-C.; Pignata, G.; Suntzeff, N. B.; Taddia, F.; Robledo, S. Torres; Valenti, S.
2018-03-01
We present an analysis of ultraviolet (UV) to near-infrared observations of the fast-declining Type Ia supernovae (SNe Ia) 2007on and 2011iv, hosted by the Fornax cluster member NGC 1404. The B-band light curves of SN 2007on and SN 2011iv are characterised by Δm15 (B) decline-rate values of 1.96 mag and 1.77 mag, respectively. Although they have similar decline rates, their peak B- and H-band magnitudes differ by 0.60 mag and 0.35 mag, respectively. After correcting for the luminosity vs. decline rate and the luminosity vs. colour relations, the peak B-band and H-band light curves provide distances that differ by 14% and 9%, respectively. These findings serve as a cautionary tale for the use of transitional SNe Ia located in early-type hosts in the quest to measure cosmological parameters. Interestingly, even though SN 2011iv is brighter and bluer at early times, by three weeks past maximum and extending over several months, its B - V colour is 0.12 mag redder than that of SN 2007on. To reconcile this unusual behaviour, we turn to guidance from a suite of spherical one-dimensional Chandrasekhar-mass delayed-detonation explosion models. In this context, 56Ni production depends on both the so-called transition density and the central density of the progenitor white dwarf. To first order, the transition density drives the luminosity-width relation, while the central density is an important second-order parameter. Within this context, the differences in the B - V colour evolution along the Lira regime suggest that the progenitor of SN 2011iv had a higher central density than SN 2007on. The photometry tables are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/611/A58
Low-energy light bulbs, computers, tablets and the blue light hazard.
O'Hagan, J B; Khazova, M; Price, L L A
2016-02-01
The introduction of low energy lighting and the widespread use of computer and mobile technologies have changed the exposure of human eyes to light. Occasional claims that the light sources with emissions containing blue light may cause eye damage raise concerns in the media. The aim of the study was to determine if it was appropriate to issue advice on the public health concerns. A number of sources were assessed and the exposure conditions were compared with international exposure limits, and the exposure likely to be received from staring at a blue sky. None of the sources assessed approached the exposure limits, even for extended viewing times.
Innovative design of parabolic reflector light guiding structure
NASA Astrophysics Data System (ADS)
Whang, Allen J.; Tso, Chun-Hsien; Chen, Yi-Yung
2008-02-01
Due to the idea of everlasting green architecture, it is of increasing importance to guild natural light into indoors. The advantages are multifold - to have better color rendering index, excellent energy savings from environments viewpoints and make humans more healthy, etc. Our search is to design an innovative structure, to convert outdoor sun light impinges on larger surfaces, into near linear light beam sources, later convert this light beam into near point sources which enters the indoor spaces then can be used as lighting sources indoors. We are not involved with the opto-electrical transformation, to the guild light into to the building, to perform the illumination, as well as the imaging function. Because non-imaging optics, well known for apply to the solar concentrators, that can use non-imaging structures to fulfill our needs, which can also be used as energy collectors in solar energy devices. Here, we have designed a pair of large and small parabolic reflector, which can be used to collect daylight and change area from large to small. Then we make a light-guide system that is been designed by us use of this parabolic reflector to guide the collection light, can pick up the performance for large surface source change to near linear source and a larger collection area.
Seeing "the Dress" in the Right Light: Perceived Colors and Inferred Light Sources.
Chetverikov, Andrey; Ivanchei, Ivan
2016-08-01
In the well-known "dress" photograph, people either see the dress as blue with black stripes or as white with golden stripes. We suggest that the perception of colors is guided by the scene interpretation and the inferred positions of light sources. We tested this hypothesis in two online studies using color matching to estimate the colors observers see, while controlling for individual differences in gray point bias and color discrimination. Study 1 demonstrates that the interpretation of the dress corresponds to differences in perceived colors. Moreover, people who perceive the dress as blue-and-black are two times more likely to consider the light source as frontal, than those who see the white-and-gold dress. The inferred light sources, in turn, depend on the circadian changes in ambient light. The interpretation of the scene background as a wall or a mirror is consistent with the perceived colors as well. Study 2 shows that matching provides reliable results on differing devices and replicates the findings on scene interpretation and light sources. Additionally, we show that participants' environmental lighting conditions are an important cue for perceiving the dress colors. The exact mechanisms of how environmental lighting and circadian changes influence the perceived colors of the dress deserve further investigation.
NASA Astrophysics Data System (ADS)
Skopal, A.; Vanko, M.; Pribulla, T.; Wolf, M.; Semkov, E.; Jones, A.
2002-04-01
We present new photometric observations of EG And, Z And, BF Cyg, CH Cyg, V1329 Cyg, AG Dra, RW Hya, AX Per and IV Vir made in the standard Johnson UBVR system. The current issue summarizes observations of these objects to 2001 December. The main results can be summarized as follows: EG And: A periodic double-wave variation in all bands as a function of the orbital phase was confirmed. A maximum of the light changes was observed in U (Delta U ~ 0.5 mag). Z And: Our observations cover an active phase, which peaked around 8.4 in U at the beginning of 2000 December. Consequently, a gradual decrease in the star's brightness has been observed. BF Cyg: A periodic wave-like variation in the optical continuum reflects a quiescent phase of this star. A complex light curve (LC) profile was observed. CH Cyg: The recent episode of activity ended in Spring 2000. We determined the position of an eclipse in the outer binary at JD 2451426 +/- 3. Recent observations indicate a slow increase in the star's brightness. V1329 Cyg: Observations were made around a maximum at 2001.2. AG Dra: Our measurements from the Autumn of 2001 revealed a new eruption, which peaked at ~JD 2452217. RW Hya: The light minimum in our mean visual LC precedes the time of the spectroscopic conjunction of the giant in the binary. AX Per: A periodic wave-like variation was observed. Our recent observations revealed a secondary minimum at the orbital phase 0.5, seen best in the V and B bands. IV Vir: The LC displays a double-wave throughout the orbital cycle.
Karlage, Kelly; Earhart, Zachary; Green-Boesen, Kelly; Myrdal, Paul B
2011-08-15
The stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride (PVC) and polyolefin bags under varying conditions was evaluated. Triplicate solutions of midazolam hydrochloride 1-mg/mL were prepared in polyolefin and PVC i.v. bags by diluting midazolam hydrochloride injection 5 mg/mL with 5% dextrose injection. Bags were then stored under refrigeration (3-4 °C), exposed to light at room temperature (20-25 °C), or protected from light in amber bags at room temperature. Samples were taken immediately after preparation (day 0) and on days 1, 2, 3, 6, 13, 20, and 27 for analysis with a stability-indicating high-performance liquid chromatography assay in order to determine solution concentration. Stability was defined as retention of at least 90% of the initial drug concentration. The pH of each solution was also measured weekly. Sterility of the i.v. bags was determined at the end of the study by microbiological testing with culture in growth media. Differences in concentrations under the various storage conditions and bags used were analyzed using analysis of variance. All solutions retained over 98% of the initial midazolam hydrochloride concentration, with no statistically significant (p ≥ 0.05) change in concentration over the four-week period. Stability was not affected by temperature, exposure to light, or bag type. The pH of all solutions remained between 3.2 and 3.4 throughout the study. Sterility after 28 days was retained. Midazolam hydrochloride 1-mg/mL solutions diluted in 5% dextrose injection remained stable over 27 days in both polyolefin and PVC i.v. bags, regardless of storage condition.
Chatterjee, Pabitra B; Crans, Debbie C
2012-09-03
Visible light facilitates a solid-to-solid photochemical aerobic oxidation of a hunter-green microcrystalline oxidovanadium(IV) compound (1) to form a black powder of cis-dioxidovanadium(V) (2) at ambient temperature. The siderophore ligand pyridine-2,6-bis(thiocarboxylic acid), H(2)L, is secreted by a microorganism from the Pseudomonas genus. This irreversible transformation of a metal monooxo to a metal dioxo complex in the solid state in the absence of solvent is unprecedented. It serves as a proof-of-concept reaction for green chemistry occurring in solid matrixes.
NASA Astrophysics Data System (ADS)
Schmidt, K. B.; Huang, K.-H.; Treu, T.; Hoag, A.; Bradač, M.; Henry, A. L.; Jones, T. A.; Mason, C.; Malkan, M.; Morishita, T.; Pentericci, L.; Trenti, M.; Vulcani, B.; Wang, X.
2017-04-01
The C III] and C IV rest-frame UV emission lines are powerful probes of the ionization states of galaxies. They have furthermore been suggested as alternatives for spectroscopic redshift confirmation of objects at the epoch of reionization (z> 6), where the most frequently used redshift indicator, Lyα, is attenuated by the high fraction of neutral hydrogen in the intergalactic medium. However, currently only very few confirmations of carbon UV lines at these high redshifts exist, making it challenging to quantify these claims. Here, we present the detection of C IV λλ1548, 1551 Å in Hubble Space Telescope slitless grism spectroscopy obtained by GLASS of a Lyα emitter at z = 6.11 multiply imaged by the massive foreground galaxy cluster RXC J2248.7-4431. The C IV emission is detected at the 3σ-5σ level in two images of the source, with marginal detection in two other images. We do not detect significant C III]λλ1907, 1909 Å emission implying an equivalent width {{EW}}{{C}{{III}}]}< 20 Å (1σ) and {{C}} {{IV}}/{{C}} {{III}}> 0.7 (2σ). Combined with limits on the rest-frame UV flux from the He II λ1640 Å emission line and the O III]λλ1661, 1666 Å doublet, we put constraints on the metallicity and the ionization state of the galaxy. The estimated line ratios and equivalent widths do not support a scenario where an AGN is responsible for ionizing the carbon atoms. SED fits, including nebular emission lines, imply a source with a mass of log(M/M ⊙) ˜ 9, SFR of around 10 M ⊙ yr-1, and a young stellar population < 50 {Myr} old. The source shows a stronger ionizing radiation field than objects with detected C IV emission at z< 2 and adds to the growing sample of low-mass (log(M/M ⊙) ≲ 9) galaxies at the epoch of reionization with strong radiation fields from star formation.
Emission factor of ammonia (NH3) from on-road vehicles in China: tunnel tests in urban Guangzhou
NASA Astrophysics Data System (ADS)
Liu, Tengyu; Wang, Xinming; Wang, Boguang; Ding, Xiang; Deng, Wei; Lü, Sujun; Zhang, Yanli
2014-05-01
Ammonia (NH3) is the primary alkaline gas in the atmosphere that contributes to formation of secondary particles. Emission of NH3 from vehicles, particularly gasoline powered light duty vehicles equipped with three-way catalysts, is regarded as an important source apart from emissions from animal wastes and soils, yet measured emission factors for motor vehicles are still not available in China, where traffic-related emission has become an increasingly important source of air pollutants in urban areas. Here we present our tunnel tests for NH3 from motor vehicles under ‘real world conditions’ in an urban roadway tunnel in Guangzhou, a central city in the Pearl River Delta (PRD) region in south China. By attributing all NH3 emissions in the tunnel to light-duty gasoline vehicles, we obtained a fuel-based emission rate of 2.92 ± 0.18 g L-1 and a mileage-based emission factor of 229.5 ± 14.1 mg km-1. These emission factors were much higher than those measured in the United States while measured NO x emission factors (7.17 ± 0.60 g L-1 or 0.56 ± 0.05 g km-1) were contrastingly near or lower than those previously estimated by MOBILE/PART5 or COPERT IV models. Based on the NH3 emission factors from this study, on-road vehicles accounted for 8.1% of NH3 emissions in the PRD region in 2006 instead of 2.5% as estimated in a previous study using emission factors taken from the Emission Inventory Improvement Program (EIIP) in the United States.
Wang, Xingyu; Gronchi, Fabrizio; Bensimon, Michael; Mercier, Thomas; Decosterd, Laurent Arthur; Wagnières, Georges; Debefve, Elodie; Ris, Hans-Beat; Letovanec, Igor; Peters, Solange; Perentes, Jean Yannis
2015-12-01
Low-dose, Visudyne®-mediated photodynamic therapy (photo-induction) was shown to selectively enhance tumor vessel transport causing increased uptake of systemically administered chemotherapy in various tumor types grown on rodent lungs. The present experiments explore the efficacy of photo-induced vessel modulation combined to intravenous (IV) liposomal cisplatin (Lipoplatin®) on rodent lung tumors and the feasibility/toxicity of this approach in porcine chest cavities. Three groups of Fischer rats underwent orthotopic sarcoma (n = 14), mesothelioma (n = 14), or adenocarcinoma (n = 12) implantation on the left lung. Half of the animals of each group had photo-induction (0.0625 mg/kg Visudyne®, 10 J/cm(2) ) followed by IV administration of Lipoplatin® (5 mg/kg) and the other half received Lipoplatin® without photo-induction. Then, two groups of minipigs underwent intrapleural thoracoscopic (VATS) photo-induction (0.0625 mg/kg Visudyne®; 30 J/cm(2) hilum; 10 J/cm(2) apex/diaphragm) with in situ light dosimetry in combination with IV Lipoplatin® administration (5 mg/kg). Protocol I (n = 6) received Lipoplatin® immediately after light delivery and Protocol II (n = 9) 90 minutes before light delivery. Three additional animals received Lipoplatin® and VATS pleural biopsies but no photo-induction (controls). Lipoplatin® concentrations were analyzed in blood and tissues before and at regular intervals after photo-induction using inductively coupled plasma mass spectrometry. Photo-induction selectively increased Lipoplatin® uptake in all orthotopic tumors. It significantly increased the ratio of tumor to lung Lipoplatin® concentration in sarcoma (P = 0.0008) and adenocarcinoma (P = 0.01) but not in mesothelioma, compared to IV drug application alone. In minipigs, intrapleural photo-induction combined to systemic Lipoplatin® was well tolerated with no toxicity at 7 days for both treatment protocols. The pleural Lipoplatin® concentrations were not significantly different at 10 and 30 J/cm(2) locations but they were significantly higher in protocol I compared to II (2.37 ± 0.7 vs. 1.37 ± 0.7 ng/mg, P < 0.001). Visudyne®-mediated photo-induction selectively enhances the uptake of IV administered Lipoplatin® in rodent lung tumors. Intrapleural VATS photo-induction with identical treatment conditions combined to IV Lipoplatin chemotherapy is feasible and well tolerated in a porcine model. Lasers Surg. Med. 47:807-816, 2015. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Pardo, Pedro J; Cordero, Eduardo M; Suero, María Isabel; Pérez, Ángel L
2012-02-01
It is well known that there are different preferences in correlated color temperature of light sources for daily living activities or for viewing artistic paintings. There are also data relating the capacity of observers to make judgments on color differences with the spectral power distribution of the light source used. The present work describes a visual color discrimination experiment whose results confirm the existence of a relationship between the correlated color temperature of a light source and the color discrimination capacities of the observers. © 2012 Optical Society of America
Rapid Optical Shutter, Chopper, Modulator and Deflector
NASA Technical Reports Server (NTRS)
Danehy, Paul M. (Inventor)
2017-01-01
An optical device with a light source and a detector is provided. A digital micromirror device positioned between the detector and the light source may deflect light beams projected from the light source. An aperture in front of the detector may block an incoming light beam from the detector when the incoming light beam is incident on the detector outside of a passable incident range and including an aperture opening configured to pass the incoming light beam to the detector when the incoming light beam is incident on the detector within a passable incident range. The digital micromirror device may rotate between a first position causing the light beam to pass through the aperture opening and a second position causing the light beam to be blocked by the aperture. The optical device may be configured to operate as a shutter, chopper, modulator and/or deflector.
Light use efficiency for vegetables production in protected and indoor environments
NASA Astrophysics Data System (ADS)
Cocetta, Giacomo; Casciani, Daria; Bulgari, Roberta; Musante, Fulvio; Kołton, Anna; Rossi, Maurizio; Ferrante, Antonio
2017-01-01
In recent years, there is a growing interest for vegetables production in indoor or disadvantaged climatic zones by using greenhouses. The main problem of crop growing indoor or in environment with limited light availability is the correct choice of light source and the quality of lighting spectrum. In greenhouse and indoor cultivations, plant density is higher than in the open field and plants have to compete for light and nutrients. Nowadays, advanced systems for indoor horticulture use light emitting diodes (LED) for improving crop growth, enhancing the plant productivity and favouring the best nutritional quality formation. In closed environments, as indoor growing modules, the lighting system represents the only source of light and its features are fundamental for obtaining the best lighting performances for plant and the most efficient solution. LED lighting engines are more efficient compared to the lighting sources used traditionally in horticulture and allow light spectrum and intensity modulations to enhance the light use efficiency for plants. The lighting distribution and the digital controls are fundamental for tailoring the spectral distribution on each plant in specific moments of its growth and play an important role for optimizing growth and produce high-quality vegetables. LED lights can increase plant growth and yield, but also nutraceutical quality, since some light intensities increase pigments biosynthesis and enhance the antioxidants content of leaves or fruits: in this regards the selection of LED primary light sources in relation to the peaks of the absorbance curve of the plants is important.
A broadband LED source in visible to short-wave-infrared wavelengths for spectral tumor diagnostics
NASA Astrophysics Data System (ADS)
Hayashi, Daiyu; van Dongen, Anne Marie; Boerekamp, Jack; Spoor, Sandra; Lucassen, Gerald; Schleipen, Jean
2017-06-01
Various tumor types exhibit the spectral fingerprints in the absorption and reflection spectra in visible and especially in near- to short-wave-infrared wavelength ranges. For the purpose of spectral tumor diagnostics by means of diffuse reflectance spectroscopy, we developed a broadband light emitting diode (LED) source consisting of a blue LED for optical excitation, Lu3Al5O12:Ce3+,Cr3+ luminescent garnet for visible to near infrared emissions, and Bismuth doped GeO2 luminescent glass for near-infrared to short-wave infrared emissions. It emits broad-band light emissions continuously in 470-1600 nm with a spectral gap at 900-1000 nm. In comparison to the currently available broadband light sources like halogen lamps, high-pressure discharge lamps and super continuum lasers, the light sources of this paper has significant advantages for spectral tissue diagnostics in high-spectral stability, improved light coupling to optical fibers, potential in low light source cost and enabling battery-drive.
The fabrication and optical detection of a vertical structure organic thin film transistor
NASA Astrophysics Data System (ADS)
Zhang, H.; Wang, D.; Jia, P.
2014-03-01
Using vacuum evaporation and sputtering process, we prepared a photoelectric transistor with the vertical structure of Cu/copper phthalocyanine (CuPc)/Al/copper phthalocyanine (CuPc)/ITO. The material of CuPc semiconductor has good photosensitive properties. Excitons will be generated after the optical signal irradiation in semiconductor material, and then transformed into photocurrent under the built-in electric field formed by the Schottky contact, as the organic transistor drive current makes the output current enlarged. The results show that the I-V characteristics of transistor are unsaturated. When device was irradiated by full band (white) light, its working current significantly increased. In full band white light, when Vec = 3 V, the ratio of light and no light current was ranged for 2.9-6.4 times. Device in the absence of light current amplification coefficient is 16.5, and white light amplification coefficient is 98.65.
Apparatus and method for generating partially coherent illumination for photolithography
Sweatt, William C.
2001-01-01
The present invention introduces a novel scatter plate into the optical path of source light used for illuminating a replicated object. The scatter plate has been designed to interrupt a focused, incoming light beam by introducing between about 8 to 24 diffraction zones blazed onto the surface of the scatter plate which intercept the light and redirect it to a like number of different positions in the condenser entrance pupil each of which is determined by the relative orientation and the spatial frequency of the diffraction grating in each of the several zones. Light falling onto the scatter plate, therefore, generates a plurality of unphased sources of illumination as seen by the back half of the optical system. The system comprises a high brightness source, such as a laser, creating light which is taken up by a beam forming optic which focuses the incoming light into a condenser which in turn, focuses light into a field lens creating Kohler illumination image of the source in a camera entrance pupil. The light passing through the field lens illuminates a mask which interrupts the source light as either a positive or negative image of the object to be replicated. Light passing by the mask is focused into the entrance pupil of the lithographic camera creating an image of the mask onto a receptive media.
A Geometric Model for Specularity Prediction on Planar Surfaces with Multiple Light Sources.
Morgand, Alexandre; Tamaazousti, Mohamed; Bartoli, Adrien
2018-05-01
Specularities are often problematic in computer vision since they impact the dynamic range of the image intensity. A natural approach would be to predict and discard them using computer graphics models. However, these models depend on parameters which are difficult to estimate (light sources, objects' material properties and camera). We present a geometric model called JOLIMAS: JOint LIght-MAterial Specularity, which predicts the shape of specularities. JOLIMAS is reconstructed from images of specularities observed on a planar surface. It implicitly includes light and material properties, which are intrinsic to specularities. This model was motivated by the observation that specularities have a conic shape on planar surfaces. The conic shape is obtained by projecting a fixed quadric on the planar surface. JOLIMAS thus predicts the specularity using a simple geometric approach with static parameters (object material and light source shape). It is adapted to indoor light sources such as light bulbs and fluorescent lamps. The prediction has been tested on synthetic and real sequences. It works in a multi-light context by reconstructing a quadric for each light source with special cases such as lights being switched on or off. We also used specularity prediction for dynamic retexturing and obtained convincing rendering results. Further results are presented as supplementary video material, which can be found on the Computer Society Digital Library at http://doi.ieeecomputersociety.org/10.1109/TVCG.2017.2677445.
Apparatus and method for generating partially coherent illumination for photolithography
Sweatt, W.C.
1999-07-06
The present invention relates an apparatus and method for creating a bright, uniform source of partially coherent radiation for illuminating a pattern, in order to replicate an image of said pattern with a high degree of acuity. The present invention introduces a novel scatter plate into the optical path of source light used for illuminating a replicated object. The scatter plate has been designed to interrupt a focused, incoming light beam by introducing between about 8 to 24 diffraction zones blazed onto the surface of the scatter plate which intercept the light and redirect it to a like number of different positions in the condenser entrance pupil each of which is determined by the relative orientation and the spatial frequency of the diffraction grating in each of the several zones. Light falling onto the scatter plate, therefore, generates a plurality of unphased sources of illumination as seen by the back half of the optical system. The system includes a high brightness source, such as a laser, creating light which is taken up by a beam forming optic which focuses the incoming light into a condenser which in turn, focuses light into a field lens creating Kohler illumination image of the source in a camera entrance pupil. The light passing through the field lens illuminates a mask which interrupts the source light as either a positive or negative image of the object to be replicated. Light passing by the mask is focused into the entrance pupil of the lithographic camera creating an image of the mask onto a receptive media. 7 figs.
Apparatus and method for generating partially coherent illumination for photolithography
Sweatt, William C.
1999-01-01
The present invention relates an apparatus and method for creating a bright, uniform source of partially coherent radiation for illuminating a pattern, in order to replicate an image of said pattern with a high degree of acuity. The present invention introduces a novel scatter plate into the optical path of source light used for illuminating a replicated object. The scatter plate has been designed to interrupt a focused, incoming light beam by introducing between about 8 to 24 diffraction zones blazed onto the surface of the scatter plate which intercept the light and redirect it to a like number of different positions in the condenser entrance pupil each of which is determined by the relative orientation and the spatial frequency of the diffraction grating in each of the several zones. Light falling onto the scatter plate, therefore, generates a plurality of unphased sources of illumination as seen by the back half of the optical system. The system includes a high brightness source, such as a laser, creating light which is taken up by a beam forming optic which focuses the incoming light into a condenser which in turn, focuses light into a field lens creating Kohler illumination image of the source in a camera entrance pupil. The light passing through the field lens illuminates a mask which interrupts the source light as either a positive or negative image of the object to be replicated. Light passing by the mask is focused into the entrance pupil of the lithographic camera creating an image of the mask onto a receptive media.
Conceptual design of a stray light facility for Earth observation satellites
NASA Astrophysics Data System (ADS)
Stockman, Y.; Hellin, M. L.; Marcotte, S.; Mazy, E.; Versluys, J.; François, M.; Taccola, M.; Zuccaro Marchi, A.
2017-11-01
With the upcoming of TMA or FMA (Three or Four Mirrors Anastigmat) telescope design in Earth Observation system, stray light is a major contributor to the degradation of the image quality. Numerous sources of stray light can be identified and theoretically evaluated. Nevertheless in order to build a stray light model of the instrument, the Point Spread Function(s) of the instrument, i.e., the flux response of the instrument to the flux received at the instrument entrance from an infinite distant point source needs to be determined. This paper presents a conceptual design of a facility placed in a vacuum chamber to eliminate undesired air particles scatter light sources. The specification of the clean room class or vacuum will depend on the required rejection to be measured. Once the vacuum chamber is closed, the stray light level from the external environment can be considered as negligible. Inside the chamber a dedicated baffle design is required to eliminate undesired light generated by the set up itself e.g. retro reflected light away from the instrument under test. This implies blackened shrouds all around the specimen. The proposed illumination system is a 400 mm off axis parabolic mirror with a focal length of 2 m. The off axis design suppresses the problem of stray light that can be generated by the internal obstruction. A dedicated block source is evaluated in order to avoid any stray light coming from the structure around the source pinhole. Dedicated attention is required on the selection of the source to achieve the required large measurement dynamic.
2011-07-06
biaxial compressive strain is known to split the light- and heavy-hole bands, reducing the interband scattering and causing the light hole band to move up...and heterostructure design are presented. In Section V, we use temperature- dependent measurements and pulsed I-V measurements to analyze the results...minimal in our devices. The temperature dependence of hole mobility was stud- ied for both the surface and buried channel devices, as plot- ted in Fig
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, C.J.; Kross, B.J.; Majewski, S.; Wojcik, R.F.
1998-08-25
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools. 5 figs.
Illuminating system and method for specialized and decorative lighting using liquid light guides
Zorn, Carl J.; Kross, Brian J.; Majewski, Stanislaw; Wojcik, Randolph F.
1998-01-01
The present invention comprises an illumination system for specialized decorative lighting including a light source, a flexible plastic tube sheath for distributing the light to a remote location, a transparent liquid core filling the tube that has an index of refraction greater than that of the plastic tube and an arrangement where light coupled from the light source is caused to leak from the liquid light guide at desired locations for the purposes of specialized lighting, such as underwater illumination in swimming pools.
Hansen, Anthony D.
1990-01-01
An improved aethalometer (10) having a single light source (18) and a single light detector (20) and two light paths (21, 22) from the light source (18) to the light detector (20). A quartz fiber filter (13) is inserted in the device, the filter (13) having a collection area (23) in one light path (21) and a reference area (24) in the other light path (22). A gas flow path (46) through the aethalometer housing (11) allows ambient air to flow through the collection area (23) of the filter (13) so that aerosol particles can be collected on the filter. A rotating disk (31) with an opening (33) therethrough allows light for the light source (18) to pass alternately through the two light paths (21, 22). The voltage output of the detector (20) is applied to a VCO (52) and the VCO pulses for light transmission separately through the two light paths (21, 22 ) are counted and compared to determine the absorption coefficient of the collected aerosol particles.
Centralized light-source optical access network based on polarization multiplexing.
Grassi, Fulvio; Mora, José; Ortega, Beatriz; Capmany, José
2010-03-01
This paper presents and demonstrates a centralized light source optical access network based on optical polarization multiplexing technique. By using two optical sources emitting light orthogonally polarized in the Central Node for downstream and upstream operations, the Remote Node is kept source-free. EVM values below telecommunication standard requirements have been measured experimentally when bidirectional digital signals have been transmitted over 10 km of SMF employing subcarrier multiplexing technique in the electrical domain.
Hard X-ray Sources for the Mexican Synchrotron Project
NASA Astrophysics Data System (ADS)
Reyes-Herrera, Juan
2016-10-01
One of the principal tasks for the design of the Mexican synchrotron was to define the storage ring energy. The main criteria for choosing the energy come from studying the electromagnetic spectrum that can be obtained from the synchrotron, because the energy range of the spectrum that can be obtained will determine the applications available to the users of the future light source. Since there is a public demand of hard X-rays for the experiments in the synchrotron community users from Mexico, in this work we studied the emission spectra from some hard X-ray sources which could be the best options for the parameters of the present Mexican synchrotron design. The calculations of the flux and the brightness for one Bending Magnet and four Insertion Devices are presented; specifically, for a Superconducting Bending Magnet (SBM), a Superconducting Wiggler (SCW), an In Vacuum Short Period Undulator (IV-SPU), a Superconducting Undulator (SCU) and for a Cryogenic Permanent Magnet Undulator (CPMU). Two commonly available synchrotron radiation programs were used for the computation (XOP and SRW). From the results, it can be concluded that the particle beam energy from the current design is enough to have one or more sources of hard X-rays. Furthermore, a wide range of hard X-ray region can be covered by the analyzed sources, and the choice of each type should be based on the specific characteristics of the X-ray beam to perform the experiments at the involved beamline. This work was done within the project Fomix Conacyt-Morelos ”Plan Estrategico para la construccion y operación de un Sincrotron en Morelos” (224392).
Extended source effect on microlensing light curves by an Ellis wormhole
NASA Astrophysics Data System (ADS)
Tsukamoto, Naoki; Gong, Yungui
2018-04-01
We can survey an Ellis wormhole which is the simplest Morris-Thorne wormhole in our Galaxy with microlensing. The light curve of a point source microlensed by the Ellis wormhole shows approximately 4% demagnification while the total magnification of images lensed by a Schwarzschild lens is always larger than unity. We investigate an extended source effect on the light curves microlensed by the Ellis wormhole. We show that the depth of the gutter of the light curves of an extended source is smaller than the one of a point source since the magnified part of the extended source cancels the demagnified part out. We can, however, distinguish between the light curves of the extended source microlensed by the Ellis wormhole and the ones by the Schwarzschild lens in their shapes even if the size of the source is a few times larger than the size of an Einstein ring on a source plane. If the relative velocity of a star with the radius of 1 06 km at 8 kpc in the bulge of our Galaxy against an observer-lens system is smaller than 10 km /s on a source plane, we can detect microlensing of the star lensed by the Ellis wormhole with the throat radius of 1 km at 4 kpc.
Identifying potential sources of Sudan I contamination in Capsicum fruits over its growth period.
Wu, Naiying; Gao, Wei; Zhou, Li; Lian, Yunhe; Li, Fengfei; Han, Wenjie
2015-04-15
Sudan dyes in spices are often assumed to arise from cross-contamination or malicious addition. Here, experiments were carried out to identify the potential source of Sudan I-IV in Capsicum fruits through investigation of their contents in native Capsicum tissues, soils and associated agronomic materials. Sudan II-IV was not detected in any of the tested samples. Sudan I was found in almost all samples except for the mulching film. Sudan I concentrations decreased from stems to leaves and then to fruits or roots. Sudan I levels in soils were significantly elevated by vegetation treatment. These results exclude the possibility of soil as the main source for Sudan I contamination in Capsicum fruits. Further study found out pesticide and fertilizer constitutes the major source of Sudan I contamination. This work represents a preliminary step for a detailed Sudan I assessment to support Capsicum management and protection in the studied region. Copyright © 2014 Elsevier Ltd. All rights reserved.
X-ray micro-Tomography at the Advanced Light Source
USDA-ARS?s Scientific Manuscript database
The X-ray micro-Tomography Facility at the Advanced Light Source has been in operation since 2004. The source is a superconducting bend magnet of critical energy 10.5KeV; photon energy coverage is 8-45 KeV in monochromatic mode, and a filtered white light option yields useful photons up to 50 KeV. A...
Reflector system for a lighting fixture
Siminovitch, M.J.; Page, E.; Gould, C.T.
1998-09-08
Disclosed herein is a reflector system for a lighting fixture having a illumination source surrounded by an envelope. The reflector system includes a first reflector surrounding the illumination source. The reflector system also includes a second reflector which is non-contiguous with the first reflector and which surrounds the illumination source. The illumination source creates light rays which are reflected by the first and second reflectors. The first reflector directs light rays toward the center line of the fixture. However, the reflected rays despite being so reflected do not substantially intersect the envelope. The reflected light rays from the second reflector being directed so that they diverge from the center line of the fixture avoiding intersection with the semi-transparent envelope. 5 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.
Minimum color quality standards are necessary, because the light sources most efficient at producing lumens are impractical for use in architectural lighting due to poor color rendition. Thus, accurate measures of color rendition and accompanying performance criteria are essential for helping technology developers and users balance tradeoffs between energy efficiency and lighting quality. Setting higher color-rendition criteria while maintaining use of CRI (e.g., CRI ≥ 90) may filter out some unacceptable light sources, but also filters out many highly desirable light sources and requires a greater tradeoff with energy efficiency. In contrast, specifying color rendition using TM-30 Rf, Rg, andmore » Rcs,h1 has been shown to be effective for differentiating desirable sources while maintaining flexibility for technology development and energy efficiency.« less
Optimization of light source parameters in the photodynamic therapy of heterogeneous prostate
NASA Astrophysics Data System (ADS)
Li, Jun; Altschuler, Martin D.; Hahn, Stephen M.; Zhu, Timothy C.
2008-08-01
The three-dimensional (3D) heterogeneous distributions of optical properties in a patient prostate can now be measured in vivo. Such data can be used to obtain a more accurate light-fluence kernel. (For specified sources and points, the kernel gives the fluence delivered to a point by a source of unit strength.) In turn, the kernel can be used to solve the inverse problem that determines the source strengths needed to deliver a prescribed photodynamic therapy (PDT) dose (or light-fluence) distribution within the prostate (assuming uniform drug concentration). We have developed and tested computational procedures to use the new heterogeneous data to optimize delivered light-fluence. New problems arise, however, in quickly obtaining an accurate kernel following the insertion of interstitial light sources and data acquisition. (1) The light-fluence kernel must be calculated in 3D and separately for each light source, which increases kernel size. (2) An accurate kernel for light scattering in a heterogeneous medium requires ray tracing and volume partitioning, thus significant calculation time. To address these problems, two different kernels were examined and compared for speed of creation and accuracy of dose. Kernels derived more quickly involve simpler algorithms. Our goal is to achieve optimal dose planning with patient-specific heterogeneous optical data applied through accurate kernels, all within clinical times. The optimization process is restricted to accepting the given (interstitially inserted) sources, and determining the best source strengths with which to obtain a prescribed dose. The Cimmino feasibility algorithm is used for this purpose. The dose distribution and source weights obtained for each kernel are analyzed. In clinical use, optimization will also be performed prior to source insertion to obtain initial source positions, source lengths and source weights, but with the assumption of homogeneous optical properties. For this reason, we compare the results from heterogeneous optical data with those obtained from average homogeneous optical properties. The optimized treatment plans are also compared with the reference clinical plan, defined as the plan with sources of equal strength, distributed regularly in space, which delivers a mean value of prescribed fluence at detector locations within the treatment region. The study suggests that comprehensive optimization of source parameters (i.e. strengths, lengths and locations) is feasible, thus allowing acceptable dose coverage in a heterogeneous prostate PDT within the time constraints of the PDT procedure.
Yang, Ying; Wu, Nandan; Tian, Sijia; Li, Fan; Hu, Huan; Chen, Pei; Cai, Xiaoxiao; Xu, Lijun; Zhang, Jing; Chen, Zhao; Ge, Jian; Yu, Keming; Zhuang, Jing
2016-11-17
Neurons display genomic fragility and show fragmented DNA in pathological degeneration. A failure to repair DNA breaks may result in cell death or apoptosis. Lithium protects retinal neurocytes following nutrient deprivation or partial nerve crush, but the underlying mechanisms are not well defined. Here we demonstrate that pretreatment with lithium protects retinal neurocytes from ischemia-induced damage and enhances light response in rat retina following ischemia-reperfusion injury. Moreover, we found that DNA nonhomologous end-joining (NHEJ) repair is implicated in this process because in ischemic retinal neurocytes, lithium significantly reduces the number of γ-H2AX foci (well-characterized markers of DNA double-strand breaks in situ) and increases the DNA ligase IV expression level. Furthermore, we also demonstrate that nuclear respiratory factor 1 (Nrf-1) and phosphorylated cyclic AMP-response element binding protein-1 (P-CREB1) bind to ligase IV promoter to cause upregulation of ligase IV in neurocytes. The ischemic upregulation of Nrf-1 and lithium-induced increase of P-CREB1 cooperate to promote transcription of ligase IV. Short hairpin RNAs against Nrf-1 and CREB1 could significantly inhibit the increase in promoter activity and expression of ligase IV observed in the control oligos following lithium treatment in retinal neurocytes. More importantly, ischemic stimulation triggers the expression of ligase IV. Taken together, our results thus reveal a novel mechanism that lithium offers neuroprotection from ischemia-induced damage by enhancing DNA NHEJ repair.
Yang, Ying; Wu, Nandan; Tian, Sijia; Li, Fan; Hu, Huan; Chen, Pei; Cai, Xiaoxiao; Xu, Lijun; Zhang, Jing; Chen, Zhao; Ge, Jian; Yu, Keming; Zhuang, Jing
2016-01-01
Neurons display genomic fragility and show fragmented DNA in pathological degeneration. A failure to repair DNA breaks may result in cell death or apoptosis. Lithium protects retinal neurocytes following nutrient deprivation or partial nerve crush, but the underlying mechanisms are not well defined. Here we demonstrate that pretreatment with lithium protects retinal neurocytes from ischemia-induced damage and enhances light response in rat retina following ischemia–reperfusion injury. Moreover, we found that DNA nonhomologous end-joining (NHEJ) repair is implicated in this process because in ischemic retinal neurocytes, lithium significantly reduces the number of γ-H2AX foci (well-characterized markers of DNA double-strand breaks in situ) and increases the DNA ligase IV expression level. Furthermore, we also demonstrate that nuclear respiratory factor 1 (Nrf-1) and phosphorylated cyclic AMP-response element binding protein-1 (P-CREB1) bind to ligase IV promoter to cause upregulation of ligase IV in neurocytes. The ischemic upregulation of Nrf-1 and lithium-induced increase of P-CREB1 cooperate to promote transcription of ligase IV. Short hairpin RNAs against Nrf-1 and CREB1 could significantly inhibit the increase in promoter activity and expression of ligase IV observed in the control oligos following lithium treatment in retinal neurocytes. More importantly, ischemic stimulation triggers the expression of ligase IV. Taken together, our results thus reveal a novel mechanism that lithium offers neuroprotection from ischemia-induced damage by enhancing DNA NHEJ repair. PMID:27853172
Guo, Liangqia; Xie, Zenghong; Lin, Xucong; Liu, Xiaohua; Zhang, Weilin; Chen, Guonan
2004-01-01
A flow-injection chemiluminescence method for the determination of tetracycline was developed. The method is based on an enhancement by tetracycline of the chemiluminescence light emission of tris(2,2'-bipyridine)ruthenium(II). In sulphuric acid medium, the chemiluminescence is generated by the continuous oxidation of tris(2,2'-bipyridine)ruthenium(II) by cerium (IV) sulphate. The light-emission intensity is greatly enhanced in the presence of tetracycline. Under the optimum conditions, the calibration curve is linear over the range 3.75 x 10(-8) g/mL-1.5 x 10(-5) g/mL for tetracycline with the linear equation: deltaINT = 205.898 x C - 20.442 (R2 = 0.9974). The detection limit is 3.27 x 10(-8) g/mL. The proposed method was also successfully used to determine tetracycline in pharmaceutical formulation (mean recovery of tetracycline, 100.7%). Copyright 2004 John Wiley & Sons, Ltd.
Structure and function of homodomain-leucine zipper (HD-Zip) proteins.
Elhiti, Mohamed; Stasolla, Claudio
2009-02-01
Homeodomain-leucine zipper (HD-Zip) proteins are transcription factors unique to plants and are encoded by more than 25 genes in Arabidopsis thaliana. Based on sequence analyses these proteins have been classified into four distinct groups: HD-Zip I-IV. HD-Zip proteins are characterized by the presence of two functional domains; a homeodomain (HD) responsible for DNA binding and a leucine zipper domain (Zip) located immediately C-terminal to the homeodomain and involved in protein-protein interaction. Despite sequence similarities HD-ZIP proteins participate in a variety of processes during plant growth and development. HD-Zip I proteins are generally involved in responses related to abiotic stress, abscisic acid (ABA), blue light, de-etiolation and embryogenesis. HD-Zip II proteins participate in light response, shade avoidance and auxin signalling. Members of the third group (HD-Zip III) control embryogenesis, leaf polarity, lateral organ initiation and meristem function. HD-Zip IV proteins play significant roles during anthocyanin accumulation, differentiation of epidermal cells, trichome formation and root development.
Design of a Borescope for Extravehicular Non-Destructive Applications
NASA Technical Reports Server (NTRS)
Bachnak, Rafic
2003-01-01
Anomalies such as corrosion, structural damage, misalignment, cracking, stress fiactures, pitting, or wear can be detected and monitored by the aid of a borescope. A borescope requires a source of light for proper operation. Today s current lighting technology market consists of incandescent lamps, fluorescent lamps and other types of electric arc and electric discharge vapor lamp. Recent advances in LED technology have made LEDs viable for a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. LEDs promise significant reduction in power consumption compared to other sources of light. This project focused on comparing images taken by the Olympus IPLEX, using two different light sources. One of the sources is the 50-W internal metal halide lamp and the other is a 1 W LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation [l]. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. Analysis using pattern recognition using Eigenfaces and Gaussian Pyramid in face recognition may be more useful.
Dipeptidyl(amino)peptidase IV and aminopeptidase M metabolize circulating substance P in vivo.
Ahmad, S; Wang, L; Ward, P E
1992-03-01
Recent studies have demonstrated that Fischer-344 rats from Japanese Charles River Inc. specifically lack dipeptidyl(amino)peptidase IV (DAP IV-negative; EC 3.4.14.5), whereas Fischer-344 rats from sources within the United States (DAP IV-positive) possess normal DAP IV activity. In the present study, plasma from DAP IV-positive rats metabolized substance P (SP) (5.37 +/- 0.25 nmol/min/ml) via the actions of angiotensin-converting enzyme (EC 3.4.15.1) (1.86 +/- 0.50 nmol/min/ml) and DAP IV (2.56 +/- 0.42 nmol/min/ml). DAP IV sequentially converted SP to SP[3-11] and SP[5-11]. The SP[5-11] metabolite was then rapidly hydrolyzed by plasma aminopeptidase M (AmM; EC 3.4.11.2) (36.2 +/- 4.2 nmol/min/ml). In contrast, SP metabolism by plasma from DAP IV-negative rats was less than half that of control animals (2.14 +/- 0.06 nmol/min/ml), due to a complete lack of DAP IV hydrolysis. The absence of DAP IV was not associated with any differences in angiotensin-converting enzyme-mediated hydrolysis of SP (1.45 +/- 0.11 nmol/min/ml) or AmM-mediated hydrolysis of SP[5-11] (37.1 +/- 0.9 nmol/min/ml). Consistent with this deficiency in SP metabolism, SP was more potent in vivo in stimulating salivary secretion in DAP IV-negative rats compared to DAP IV-positive animals. Potentiation was specific in that SP[5-11], an SP fragment resistant to DAP IV, was equipotent in DAP IV-negative and positive animals. SP[5-11]-induced salivary secretion was potentiated in both strains when AmM-mediated hydrolysis was inhibited by amastatin (20 nmol/min, i.v.). These data provide direct evidence for a significant role for DAP IV and AmM in the in vivo processing of SP and active SP metabolites.
[A review of mixed gas detection system based on infrared spectroscopic technique].
Dang, Jing-Min; Fu, Li; Yan, Zi-Hui; Zheng, Chuan-Tao; Chang, Yu-Chun; Chen, Chen; Wang, Yi-Din
2014-10-01
In order to provide the experiences and references to the researchers who are working on infrared (IR) mixed gas detection field. The proposed manuscript reviews two sections of the aforementioned field, including optical multiplexing structure and detection method. At present, the coherent light sources whose representative are quantum cascade laser (QCL) and inter-band cascade laser(ICL) become the mainstream light source in IR mixed gas detection, which replace the traditional non-coherent light source, such as IR radiation source and IR light emitting diode. In addition, the photon detector which has a super high detectivity and very short response time is gradually beyond thermal infrared detector, dominant in the field of infrared detector. The optical multiplexing structure is the key factor of IR mixed gas detection system, which consists of single light source multi-plexing detection structure and multi light source multiplexing detection structure. Particularly, single light source multiplexing detection structure is advantages of small volume and high integration, which make it a plausible candidate for the portable mixed gas detection system; Meanwhile, multi light source multiplexing detection structure is embodiment of time division multiplex, frequency division multiplexing and wavelength division multiplexing, and become the leading structure of the mixed gas detection system because of its wider spectral range, higher spectral resolution, etc. The detection method applied to IR mixed gas detection includes non-dispersive infrared (NDIR) spectroscopy, wavelength and frequency-modulation spectroscopy, cavity-enhanced spectroscopy and photoacoustic spectroscopy, etc. The IR mixed gas detection system designed by researchers after recognizing the whole sections of the proposed system, which play a significant role in industrial and agricultural production, environmental monitoring, and life science, etc.
Dahlberg, Jerry; Tkacik, Peter T; Mullany, Brigid; Fleischhauer, Eric; Shahinian, Hossein; Azimi, Farzad; Navare, Jayesh; Owen, Spencer; Bisel, Tucker; Martin, Tony; Sholar, Jodie; Keanini, Russell G
2017-12-04
An analog, macroscopic method for studying molecular-scale hydrodynamic processes in dense gases and liquids is described. The technique applies a standard fluid dynamic diagnostic, particle image velocimetry (PIV), to measure: i) velocities of individual particles (grains), extant on short, grain-collision time-scales, ii) velocities of systems of particles, on both short collision-time- and long, continuum-flow-time-scales, iii) collective hydrodynamic modes known to exist in dense molecular fluids, and iv) short- and long-time-scale velocity autocorrelation functions, central to understanding particle-scale dynamics in strongly interacting, dense fluid systems. The basic system is composed of an imaging system, light source, vibrational sensors, vibrational system with a known media, and PIV and analysis software. Required experimental measurements and an outline of the theoretical tools needed when using the analog technique to study molecular-scale hydrodynamic processes are highlighted. The proposed technique provides a relatively straightforward alternative to photonic and neutron beam scattering methods traditionally used in molecular hydrodynamic studies.
Ampelli, Claudio; Perathoner, Siglinda; Centi, Gabriele
2015-03-13
CO(2) conversion will be at the core of the future of low-carbon chemical and energy industry. This review gives a glimpse into the possibilities in this field by discussing (i) CO(2) circular economy and its impact on the chemical and energy value chain, (ii) the role of CO(2) in a future scenario of chemical industry, (iii) new routes for CO(2) utilization, including emerging biotechnology routes, (iv) the technology roadmap for CO(2) chemical utilization, (v) the introduction of renewable energy in the chemical production chain through CO(2) utilization, and (vi) CO(2) as a suitable C-source to move to a low-carbon chemical industry, discussing in particular syngas and light olefin production from CO(2). There are thus many stimulating possibilities offered by using CO(2) and this review shows this new perspective on CO(2) at the industrial, societal and scientific levels. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Selenoamino Acid-Enriched Green Pea as a Value-Added Plant Protein Source for Humans and Livestock.
Garousi, Farzaneh; Domokos-Szabolcsy, Éva; Jánószky, Mihály; Kovács, Andrea Balláné; Veres, Szilvia; Soós, Áron; Kovács, Béla
2017-06-01
Selenium deficiency in various degrees affects around 15% of the world's population, contributing to a variety of health problems. In this study, we examined the accumulation and biotransformation of soil applied Se-supplementation (sodium selenite and sodium selenate forms) at different concentrations, along with growth and yield formation of green pea, in a greenhouse experiment. Biotransformation of inorganic Se was evaluated using HPLC-ICP-MS for Se-species separation in the above ground parts of green pea. Results showed 3 mg kg -1 Se IV increased green pea growth biomarkers and also caused an increase in protein content in leaves by 17%. Selenomethionine represented 65% of the total selenium content in shoots, but was lower in pods and seeds (54 and 38%, respectively). Selenomethionine was the major species in all plant parts and the only organic selenium form in the lower Se IV concentration range. Elevating the dose of Se IV (≥30 mg kg -1 ) triggered detrimental effects on growth and protein content and caused higher accumulation of inorganic Se in forms of Se VI and Se IV . Selenocysteine, another organic form of proteinogenic amino acid, was determined when Se IV (≥10 mg kg -1 ) was applied in higher concentrations. Thus, agronomic biofortification using the appropriate chemical form and concentration of Se will have positive effects on green pea growth and its enriched shoots and seeds provide a value-added protein source for livestock and humans with significant increased selenomethionine.
Metildi, Cristina A; Kaushal, Sharmeela; Lee, Claudia; Hardamon, Chanae R; Snyder, Cynthia S; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael
2012-06-01
The aim of this study was to improve fluorescence laparoscopy of pancreatic cancer in an orthotopic mouse model with the use of a light-emitting diode (LED) light source and optimal fluorophore combinations. Human pancreatic cancer models were established with fluorescent FG-RFP, MiaPaca2-GFP, BxPC-3-RFP, and BxPC-3 cancer cells implanted in 6-week-old female athymic mice. Two weeks postimplantation, diagnostic laparoscopy was performed with a Stryker L9000 LED light source or a Stryker X8000 xenon light source 24 hours after tail-vein injection of CEA antibodies conjugated with Alexa 488 or Alexa 555. Cancer lesions were detected and localized under each light mode. Intravital images were also obtained with the OV-100 Olympus and Maestro CRI Small Animal Imaging Systems, serving as a positive control. Tumors were collected for histologic analysis. Fluorescence laparoscopy with a 495-nm emission filter and an LED light source enabled real-time visualization of the fluorescence-labeled tumor deposits in the peritoneal cavity. The simultaneous use of different fluorophores (Alexa 488 and Alexa 555), conjugated to antibodies, brightened the fluorescence signal, enhancing detection of submillimeter lesions without compromising background illumination. Adjustments to the LED light source permitted simultaneous detection of tumor lesions of different fluorescent colors and surrounding structures with minimal autofluorescence. Using an LED light source with adjustments to the red, blue, and green wavelengths, it is possible to simultaneously identify tumor metastases expressing fluorescent proteins of different wavelengths, which greatly enhanced the signal without compromising background illumination. Development of this fluorescence laparoscopy technology for clinical use can improve staging and resection of pancreatic cancer. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Berghea, C. T.; Dudik, R. P.; Weaver, K. A.; Kallman, T. R.
2009-01-01
We presen the first Spitzer Infrared Spectrograph (IRS) observations of the [O IV] 25.89 um emission line detected from the ultraluminous X-ray source (ULX) in Holmberg II. This line is a well established signature of high excitation usually associated with AGN. Its detection suggests that the ULX has a strong impact on the surrounding gas. A Spitzer high resolution spectral map shows that the [O IV] is coincident with the X-ray position of the ULX. The ratios of the [O IV] to lower ionization lines are similar to those observed in AGN, suggesting that a strong UV and X-ray source is responsible for the, photoionization. The best XMM-Newton data is used to model the X-ray band which is then extrapolated into the UV. We perform infrared and ultraviolet photometry, and use its previously published optical and radio data to construct the full SED for the ULX and its companion. The preferred model to describe the SED includes an accretion disk which dominates the soft X-rays but contributes little at UV and optical wavelengths. The optical counterpart is consistent with a B supergiant as previously suggested in other studies. The bolometric luminosity of the ULX suggests the presence of an intermediate-mass black hole with mass >85 M for sub-Eddington accretion or, alternatively, a stellar-mass black hole that is accreting at super-Eddington rates. In a follow-up second paper we perform detailed photoionization modeling of the infrared lines in order to constrain the bolometric luminosity of the ULX.
NASA Astrophysics Data System (ADS)
Ozden, Burcu; Yang, Chungman; Tong, Fei; Khanal, Min P.; Mirkhani, Vahid; Sk, Mobbassar Hassan; Ahyi, Ayayi Claude; Park, Minseo
2014-10-01
We have demonstrated that the depth-dependent defect distribution of the deep level traps in the AlGaN/GaN high electron mobility transistor (HEMT) epi-structures can be analyzed by using the depth-resolved ultra-violet (UV) spectroscopic photo current-voltage (IV) (DR-UV-SPIV). It is of great importance to analyze deep level defects in the AlGaN/GaN HEMT structure, since it is recognized that deep level defects are the main source for causing current collapse phenomena leading to reduced device reliability. The AlGaN/GaN HEMT epi-layers were grown on a 6 in. Si wafer by metal-organic chemical vapor deposition. The DR-UV-SPIV measurement was performed using a monochromatized UV light illumination from a Xe lamp. The key strength of the DR-UV-SPIV is its ability to provide information on the depth-dependent electrically active defect distribution along the epi-layer growth direction. The DR-UV-SPIV data showed variations in the depth-dependent defect distribution across the wafer. As a result, rapid feedback on the depth-dependent electrical homogeneity of the electrically active defect distribution in the AlGaN/GaN HEMT epi-structure grown on a Si wafer with minimal sample preparation can be elucidated from the DR-UV-SPIV in combination with our previously demonstrated spectroscopic photo-IV measurement with the sub-bandgap excitation.
NASA Technical Reports Server (NTRS)
Yorio, N. C.; Goins, G. D.; Kagie, H. R.; Wheeler, R. M.; Sager, J. C.
2001-01-01
Radish (Raphanus sativus L. cv. Cherriette), lettuce (Lactuca sativa L. cv. Waldmann's Green), and spinach (Spinacea oleracea L. cv. Nordic IV) plants were grown under 660-nm red light-emitting diodes (LEDs) and were compared at equal photosynthetic photon flux (PPF) with either plants grown under cool-white fluorescent lamps (CWF) or red LEDs supplemented with 10% (30 micromoles m-2 s-1) blue light (400-500 nm) from blue fluorescent (BF) lamps. At 21 days after planting (DAP), leaf photosynthetic rates and stomatal conductance were greater for plants grown under CWF light than for those grown under red LEDs, with or without supplemental blue light. At harvest (21 DAP), total dry-weight accumulation was significantly lower for all species tested when grown under red LEDs alone than when grown under CWF light or red LEDs + 10% BF light. Moreover, total dry weight for radish and spinach was significantly lower under red LEDs + 10% BF than under CWF light, suggesting that addition of blue light to the red LEDs was still insufficient for achieving maximal growth for these crops.
Synchrotron light sources in developing countries
Mtingwa, Sekazi K.; Winick, Herman
2018-03-21
Here, we discuss the role that synchrotron light sources, such as SESAME, could play in improving the socioeconomic conditions in developing countries. After providing a brief description of a synchrotron light source, we discuss the important role that they played in the development of several economically emerging countries. Then we describe the state of synchrotron science in South Africa and that country’s leadership role in founding the African Light Source initiative. Next, we highlight a new initiative called Lightsources for Africa, the Americas & Middle East Project, which is a global initiative led by the International Union of Pure andmore » Applied Physics and the International Union of Crystallography, with initial funding provided by the International Council for Science. Finally, we comment on a new technology called the multibend achromat that has launched a new paradigm for the design of synchrotron light sources that should be attractive for construction in developing countries.« less
Synchrotron light sources in developing countries
NASA Astrophysics Data System (ADS)
Mtingwa, Sekazi K.; Winick, Herman
2018-03-01
We discuss the role that synchrotron light sources, such as SESAME, could play in improving the socioeconomic conditions in developing countries. After providing a brief description of a synchrotron light source, we discuss the important role that they played in the development of several economically emerging countries. Then we describe the state of synchrotron science in South Africa and that country’s leadership role in founding the African Light Source initiative. Next, we highlight a new initiative called Lightsources for Africa, the Americas & Middle East Project, which is a global initiative led by the International Union of Pure and Applied Physics and the International Union of Crystallography, with initial funding provided by the International Council for Science. Finally, we comment on a new technology called the multibend achromat that has launched a new paradigm for the design of synchrotron light sources that should be attractive for construction in developing countries.
Broadband near-field infrared spectroscopy with a high temperature plasma light source.
Lahneman, D J; Huffman, T J; Xu, Peng; Wang, S L; Grogan, T; Qazilbash, M M
2017-08-21
Scattering-type scanning near-field optical microscopy (S-SNOM) has enormous potential as a spectroscopy tool in the infrared spectral range where it can probe phonon resonances and carrier dynamics at the nanometer lengths scales. However, its applicability is limited by the lack of practical and affordable table-top light sources emitting intense broadband infrared radiation in the 100 cm -1 to 2,500 cm -1 spectral range. This paper introduces a high temperature plasma light source that is both ultra-broadband and has much more radiant power in the infrared spectral range than conventional, table-top thermal light sources such as the globar. We implement this plasma lamp in our near-field optical spectroscopy set up and demonstrate its capability as a broadband infrared nano-spectroscopy light source by obtaining near-field infrared amplitude and phase spectra of the phonon resonances of SiO 2 and SrTiO 3 .
Atomic physics research with second and third generation synchrotron light sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, B.M.
1990-10-01
This contribution to these proceedings is intended to provide an introduction and overview for other contributions on atomic (and related) physics research at existing and planned synchrotron light sources. The emphasis will be on research accomplishments and future opportunities, but a comparison will be given of operating characteristics for first, second, and third generation machines. First generation light sources were built to do research with the primary electron and positron beams, rather than with the synchrotron radiation itself. Second generation machines were specifically designed to be dedicated synchrotron-radiation facilities, with an emphasis on the use of bending-magnet radiation. The newmore » third generation light sources are being designed to optimize radiation from insertion devices, such as undulators and wigglers. Each generation of synchrotron light source offers useful capabilities for forefront research in atomic physics and many other disciplines. 27 refs., 1 fig., 3 tabs.« less
Hughes, V K; Ellis, P S; Langlois, N E I
2006-05-10
The age of a bruise may be of interest to forensic investigators. Previous research has demonstrated that an alternative light source may assist in the visualisation of faint or non-visible bruises. This project aimed to determine if an alternative light source could be utilised to assist investigators estimate the age of a bruise. Forty braises, sustained from blunt force trauma, were examined from 30 healthy subjects. The age of the bruises ranged from 2 to 231 h (mean = 74.6, median = 69.0). Alternative light source (polilight) illumination at 415 and 450 nm was used. The black and white photographs obtained were assessed using densitometry. A statistical analysis indicated that there was no correlation between time and the mean densitometry values. The alternative light source used in this study was unable to assist in determining the age of a bruise.
Synchrotron light sources in developing countries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mtingwa, Sekazi K.; Winick, Herman
Here, we discuss the role that synchrotron light sources, such as SESAME, could play in improving the socioeconomic conditions in developing countries. After providing a brief description of a synchrotron light source, we discuss the important role that they played in the development of several economically emerging countries. Then we describe the state of synchrotron science in South Africa and that country’s leadership role in founding the African Light Source initiative. Next, we highlight a new initiative called Lightsources for Africa, the Americas & Middle East Project, which is a global initiative led by the International Union of Pure andmore » Applied Physics and the International Union of Crystallography, with initial funding provided by the International Council for Science. Finally, we comment on a new technology called the multibend achromat that has launched a new paradigm for the design of synchrotron light sources that should be attractive for construction in developing countries.« less
Salauze, D; Otal, I; Gomez-Lus, R; Davies, J
1990-10-01
Members of the family Enterobacteriaceae harboring an enzyme of the aminoglycoside acetyltransferase 3 class (AAC-3-IV) (apramycin and gentamicin resistance) and hygromycin B phosphotransferase 4 (HPH-4-I) (hygromycin B resistance) have been isolated from human clinical sources in Europe. A cluster of genes containing IS140, aacC4, and hphB was found in these strains. We demonstrate by Southern hybridization that this cluster is identical to the operon found in animals that also contains insertion sequences belonging to the ISO family. This provides another example of presumptive transfer of antibiotic resistance genes between bacteria of animal and human origin.
Hensman, C; Hanna, G B; Drew, T; Moseley, H; Cuschieri, A
1998-04-01
Skin burns and ignition of drapes have been reported with the use of cold light sources. The aim of the study was to document the temperature generated by cold light sources and to correlate this with the total radiated power and infrared output. The temperature, total radiated power, and infrared output were measured as a function of time at the end of the endoscope (which is inserted into the operative field) and the end of the fiber optic bundle of the light cable (which connects the cable to the light port of the endoscope) using halogen and xenon light sources. The highest temperature recorded at the end of the endoscope was 95 degrees C. The temperature measured at the optical fiber location of the endoscope was higher than at its lens surface (p < 0.0001). At the end of the fiber optic bundle of light cables, the temperature reached 225 degrees C within 15 s. The temperature recorded at the optical fiber location of all endoscopes and light cables studied rose significantly over a period of 10 min to reach its maximum (p <0.0001) and then leveled off for the duration of the study (30 min). The infrared output accounted only for 10% of the total radiated power. High temperatures are reached by 10 min at the end of fiber optic bundle of light cables and endoscopes with both halogen and xenon light sources. This heat generation is largely due to the radiated power in the visible light spectrum.
Oxygen and relative humidity monitoring with films tailored for enhanced photoluminescence
Cui, Weipan; Liu, Rui; Manna, Eeshita; ...
2014-10-31
In this study, approaches to generate porous or doped sensing films, which significantly enhance the photoluminescence (PL) of oxygen optical sensors, and thus improve the signal-to-noise (S/N) ratio, are presented. Tailored films, which enable monitoring the relative humidity (RH) as well, are also presented. Effective porous structures, in which the O 2-sensitive dye Pt octaethylporphyrin (PtOEP) or the Pd analog PdOEP was embedded, were realized by first generating blend films of polyethylene glycol (PEG) with polystyrene (PS) or with ethyl cellulose (EC), and then immersing the dried films in water to remove the water-soluble PEG. This approach creates pores (voids)more » in the sensing films. The dielectric contrast between the films’ constituents and the voids increases photon scattering, which in turn increases the optical path of the excitation light within the film, and hence light absorption by the dye, and its PL. Optimized sensing films with a PEG:PS ratio of 1:4 (PEG’s molecular weight M w ~8000) led to ~4.4× enhancement in the PL (in comparison to PS films). Lower M w ~200 PEG with a PEG:EC ratio of 1:1 led to a PL enhancement of ~4.7×. Film-dependent PL enhancements were observed at all oxygen concentrations. The strong PL enhancement enables (i) using lower dye (luminophore) concentrations, (ii) reducing power consumption and enhancing the sensor’s operational lifetime when using organic light emitting diodes (OLEDs) as excitation sources, (iii) improving performance when using compact photodetectors with no internal gain, and (iv) reliably extending the dynamic range.« less
Apparatus and method for measuring the thickness of a semiconductor wafer
Ciszek, Theodoer F.
1995-01-01
Apparatus for measuring thicknesses of semiconductor wafers, comprising: housing means for supporting a wafer in a light-tight environment; a light source mounted to the housing at one side of the wafer to emit light of a predetermined wavelength to normally impinge the wafer; a light detector supported at a predetermined distance from a side of the wafer opposite the side on which a light source impinges and adapted to receive light transmitted through the wafer; and means for measuring the transmitted light.
2016-11-29
AFRL-AFOSR-VA-TR-2016-0365 Long Wavelength Electromagnetic Light Bullets Generated by a 10.6 micron CO2 Ultrashort Pulsed Source Jerome Moloney...SUBTITLE "Long Wavelength Electromagnetic Light Bullets Generated by a 10.6 micron CO2 Ultrashort Pulsed Source 5a. CONTRACT NUMBER FA9550-15-1-0272 5b...afosr.reports.sgizmo.com/s3/> Subject: Final Report to Dr. Arje Nachman Contract/Grant Title: Long Wavelength Electromagnetic Light Bullets Generated by a 10.6
Energy-saving quality road lighting with colloidal quantum dot nanophosphors
NASA Astrophysics Data System (ADS)
Erdem, Talha; Kelestemur, Yusuf; Soran-Erdem, Zeliha; Ji, Yun; Demir, Hilmi Volkan
2014-12-01
Here the first photometric study of road-lighting white light-emitting diodes (WLEDs) integrated with semiconductor colloidal quantum dots (QDs) is reported enabling higher luminance than conventional light sources, specifically in mesopic vision regimes essential to street lighting. Investigating over 100 million designs uncovers that quality road-lighting QD-WLEDs, with a color quality scale and color rendering index ≥85, enables 13-35% higher mesopic luminance than the sources commonly used in street lighting. Furthermore, these QD-WLEDs were shown to be electrically more efficient than conventional sources with power conversion efficiencies ≥16-29%. Considering this fact, an experimental proof-of-concept QD-WLED was demonstrated, which is the first account of QD based color conversion custom designed for street lighting applications. The obtained white LED achieved the targeted mesopic luminance levels in accordance with the road lighting standards of the USA and the UK. These results indicate that road-lighting QD-WLEDs are strongly promising for energy-saving quality road lighting.
Optically pulsed electron accelerator
Fraser, John S.; Sheffield, Richard L.
1987-01-01
An optically pulsed electron accelerator can be used as an injector for a free electron laser and comprises a pulsed light source, such as a laser, for providing discrete incident light pulses. A photoemissive electron source emits electron bursts having the same duration as the incident light pulses when impinged upon by same. The photoemissive electron source is located on an inside wall of a radio frequency powered accelerator cell which accelerates the electron burst emitted by the photoemissive electron source.
Optically pulsed electron accelerator
Fraser, J.S.; Sheffield, R.L.
1985-05-20
An optically pulsed electron accelerator can be used as an injector for a free electron laser and comprises a pulsed light source, such as a laser, for providing discrete incident light pulses. A photoemissive electron source emits electron bursts having the same duration as the incident light pulses when impinged upon by same. The photoemissive electron source is located on an inside wall of a radiofrequency-powered accelerator cell which accelerates the electron burst emitted by the photoemissive electron source.
NASA Technical Reports Server (NTRS)
Morabito, D. D.; Preston, R. A.; Linfield, R. P.; Slade, M. A.; Jauncey, D. L.
1986-01-01
VLBI measurements of time delay and delay rate at 2.29 and 8.42 GHz on baselines of 10,000 km have been used to determine the positions of the milliarcsecond nuclei in 17 extragalactic radio sources with estimated accuracies of 0.1 to 0.3 arcsec. The observed sources are part of an all-sky VLBI catalog of milliarcsecond radio sources. In addition, slightly improved positions are presented for 101 sources originally reported by Morabito et al. (1983). Arcsecond positions have now been determined for 836 sources.
Low Power Switching for Antenna Reconfiguration
NASA Technical Reports Server (NTRS)
Bauhahn, Paul E. (Inventor); Becker, Robert C. (Inventor); Meyers, David W. (Inventor); Muldoon, Kelly P. (Inventor)
2008-01-01
Methods and systems for low power switching are provided. In one embodiment, an optical switching system is provided. The system comprises at least one optically controlled switch adapted to maintain one of an open state and a closed state based on an associated light signal; and at least one light source adapted to output the associated light signal to the at least one switch, wherein the at least one light source cycles the light signal on and off, wherein the at least one light source is cycled on for a sufficient duration of time and with a sufficient periodicity to maintain the optically controlled switch in one of an open state and a closed state.
Low-energy light bulbs, computers, tablets and the blue light hazard
O'Hagan, J B; Khazova, M; Price, L L A
2016-01-01
The introduction of low energy lighting and the widespread use of computer and mobile technologies have changed the exposure of human eyes to light. Occasional claims that the light sources with emissions containing blue light may cause eye damage raise concerns in the media. The aim of the study was to determine if it was appropriate to issue advice on the public health concerns. A number of sources were assessed and the exposure conditions were compared with international exposure limits, and the exposure likely to be received from staring at a blue sky. None of the sources assessed approached the exposure limits, even for extended viewing times. PMID:26768920
A non-laser light source for photodynamic therapy: in vitro effects on normal and malignant cells.
Kashtan, Hanoch; Haddad, Riad; Greenberg, Ron; Skornick, Yehuda; Kaplan, Ofer
2002-01-01
Photodynamic therapy (PDT) involves the use of photosensitizing drugs combined with light to treat tumors. Laser systems, the current source of light for PDT, have several inherent drawbacks: the spectrum is essentially monochromatic which may be problematic for second generation photosensitizers, the systems are bulky and nearly impossible to move between hospital locations and require complicated electrical and cooling installations, the cost of a typical system is enormous, and its maintenance and operation require highly trained personnel. We now introduce a new non-laser light system, Versa-Light, which appears to work as effectively and has none of the above drawbacks. A series of in vitro studies were performed using various murine and human normal and cancer cells which underwent PDT using aluminum phthalocyanine (AlPcS4) as a photosensitizer and Versa-Light as the light source. PDT of cancer cells at light energy levels of 50, 100 and 200 j/cm2 significantly decreased cell viability. PDT also decreased cell viability of normal murine splenocytes and normal human lymphocytes, but to a lesser extent. The observed significant hyperthermia was light dose-dependent. We believe that Versa-Light can replace laser systems as an enhanced light source for PDT. Further in vitro and pre-clinical studies are in progress.
Wacha, Hannes; Warren, Brian; Bassaris, Harry; Nikolaidis, Paul
2006-08-01
Intra-abdominal infections are a substantial clinical problem and an important cause of morbidity and death in the hospital. Optimal treatment requires both source control and antibiotic therapy. Sequential intravenous (IV) to oral therapy may improve patient convenience and reduce total health care costs. In this randomized, double-blind trial, the efficacy of sequential IV-to-oral ciprofloxacin plus metronidazole was compared with ceftriaxone plus metronidazole in adult patients with complicated intra-abdominal infections. The trial enrolled 531 patients, who began with IV therapy. Patients who improved clinically were switched to oral therapy on day three or later. The clinical and bacteriological responses four to six weeks after the end of therapy and the safety of the two regimens were assessed. To maintain blinding, the patients received placebo IV in the ciprofloxacin group or placebo orally in the ceftriaxone group. A total of 475 patients (235 ciprofloxacin plus metronidazole, 240 ceftriaxone plus metronidazole) were valid for evaluation of efficacy. All patients were included in the safety analysis. Of the patients valid for efficacy, 78% of the ciprofloxacin plus metronidazole group and 81% of the ceftriaxone plus metronidazole group were eligible for a switch to oral therapy. The clinical success rates were 98.9% and 96.9%, respectively, which were statistically equivalent. The clinical success rates for all patients, including those on continuous IV therapy, were 90.6% and 87.9%. Source control was achieved in more than 90% of the patients. The bacteriological eradication rates were similar in the two groups. Bacterial complications (e.g., surgical site infections, abscesses) were encountered more often in the ceftriaxone plus metronidazole group. Sequential ciprofloxacin plus metronidazole IV-to-oral therapy was statistically equivalent to ceftriaxone plus metronidazole. The switch to oral therapy with ciprofloxacin plus metronidazole was as effective and safe as continued IV therapy in patients able to tolerate enteral feeding.
Scanning computed confocal imager
George, John S.
2000-03-14
There is provided a confocal imager comprising a light source emitting a light, with a light modulator in optical communication with the light source for varying the spatial and temporal pattern of the light. A beam splitter receives the scanned light and direct the scanned light onto a target and pass light reflected from the target to a video capturing device for receiving the reflected light and transferring a digital image of the reflected light to a computer for creating a virtual aperture and outputting the digital image. In a transmissive mode of operation the invention omits the beam splitter means and captures light passed through the target.
A novel method for detecting light source for digital images forensic
NASA Astrophysics Data System (ADS)
Roy, A. K.; Mitra, S. K.; Agrawal, R.
2011-06-01
Manipulation in image has been in practice since centuries. These manipulated images are intended to alter facts — facts of ethics, morality, politics, sex, celebrity or chaos. Image forensic science is used to detect these manipulations in a digital image. There are several standard ways to analyze an image for manipulation. Each one has some limitation. Also very rarely any method tried to capitalize on the way image was taken by the camera. We propose a new method that is based on light and its shade as light and shade are the fundamental input resources that may carry all the information of the image. The proposed method measures the direction of light source and uses the light based technique for identification of any intentional partial manipulation in the said digital image. The method is tested for known manipulated images to correctly identify the light sources. The light source of an image is measured in terms of angle. The experimental results show the robustness of the methodology.
Mapping algorithm for freeform construction using non-ideal light sources
NASA Astrophysics Data System (ADS)
Li, Chen; Michaelis, D.; Schreiber, P.; Dick, L.; Bräuer, A.
2015-09-01
Using conventional mapping algorithms for the construction of illumination freeform optics' arbitrary target pattern can be obtained for idealized sources, e.g. collimated light or point sources. Each freeform surface element generates an image point at the target and the light intensity of an image point is corresponding to the area of the freeform surface element who generates the image point. For sources with a pronounced extension and ray divergence, e.g. an LED with a small source-freeform-distance, the image points are blurred and the blurred patterns might be different between different points. Besides, due to Fresnel losses and vignetting, the relationship between light intensity of image points and area of freeform surface elements becomes complicated. These individual light distributions of each freeform element are taken into account in a mapping algorithm. To this end the method of steepest decent procedures are used to adapt the mapping goal. A structured target pattern for a optics system with an ideal source is computed applying corresponding linear optimization matrices. Special weighting factor and smoothing factor are included in the procedures to achieve certain edge conditions and to ensure the manufacturability of the freefrom surface. The corresponding linear optimization matrices, which are the lighting distribution patterns of each of the freeform surface elements, are gained by conventional raytracing with a realistic source. Nontrivial source geometries, like LED-irregularities due to bonding or source fine structures, and a complex ray divergence behavior can be easily considered. Additionally, Fresnel losses, vignetting and even stray light are taken into account. After optimization iterations, with a realistic source, the initial mapping goal can be achieved by the optics system providing a structured target pattern with an ideal source. The algorithm is applied to several design examples. A few simple tasks are presented to discussed the ability and limitation of the this mothed. It is also presented that a homogeneous LED-illumination system design, in where, with a strongly tilted incident direction, a homogeneous distribution is achieved with a rather compact optics system and short working distance applying a relatively large LED source. It is shown that the lighting distribution patterns from the freeform surface elements can be significantly different from the others. The generation of a structured target pattern, applying weighting factor and smoothing factor, are discussed. Finally, freeform designs for much more complex sources like clusters of LED-sources are presented.
Lighting system combining daylight concentrators and an artificial source
Bornstein, Jonathan G.; Friedman, Peter S.
1985-01-01
A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.
40 CFR 63.1319 - PET and polystyrene affected sources-recordkeeping provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers...)(i) by demonstrating that mass emissions per mass product are less than or equal to the level...
Investigating the reasons of variability in Si IV and C IV broad absorption line troughs of quasars
NASA Astrophysics Data System (ADS)
Stathopoulos, Dimitrios; Lyratzi, Evangelia; Danezis, Emmanuel; Antoniou, Antonios; Tzimeas, Dimitrios
2017-09-01
In this paper we analyze the C IV and Si IV broad absorption troughs of two BALQSOs (J101056.69+355833.3, J114548.38+393746.6) to the individual components they consist of. By analyzing a BAL trough to its components we have the advantage to study the variations of the individual absorbing systems in the line of sight and not just the variations of the whole absorption trough or the variations of selected portions of BAL troughs exhibiting changes. We find that the velocity shifts and FWHMs (Full Width at Half Maximum) of the individual components do not vary between an interval of six years. All variable components show changes in the optical depths at line centers which are manifested as variations in the EW (Equivalent Width) of the components. In both BALQSOs, over corresponding velocities, Si IV has higher incidence of variability than C IV. From our analysis, evidence is in favour of different covering fractions between C IV and Si IV. Finally, although most of our results favour the crossing cloud scenario as the cause of variability, there is also strong piece of evidence indicating changing ionization as the source of variability. Thus, a mixed situation where both physical mechanisms contribute to BAL variability is the most possible scenario.
Tribal child welfare. Interim final rule.
2012-01-06
The Administration for Children and Families (ACF) is issuing this interim final rule to implement statutory provisions related to the Tribal title IV-E program. Effective October 1, 2009, section 479B(b) of the Social Security Act (the Act) authorizes direct Federal funding of Indian Tribes, Tribal organizations, and Tribal consortia that choose to operate a foster care, adoption assistance and, at Tribal option, a kinship guardianship assistance program under title IV-E of the Act. The Fostering Connections to Success and Increasing Adoptions Act of 2008 requires that ACF issue interim final regulations which address procedures to ensure that a transfer of responsibility for the placement and care of a child under a State title IV-E plan to a Tribal title IV-E plan occurs in a manner that does not affect the child's eligibility for title IV-E benefits or medical assistance under title XIX of the Act (Medicaid) and such services or payments; in-kind expenditures from third-party sources for the Tribal share of administration and training expenditures under title IV-E; and other provisions to carry out the Tribal-related amendments to title IV-E. This interim final rule includes these provisions and technical amendments necessary to implement a Tribal title IV-E program.
40 CFR 63.2480 - What requirements must I meet for equipment leaks?
Code of Federal Regulations, 2011 CFR
2011-07-01
... affected source. (5) For pumps in light liquid service in an MCPU that has no continuous process vents and.../vapor and light liquid service at an existing source, you may elect to comply with the requirements in... light liquid service in an MCPU that has no continuous process vents and is part of an existing source...
Light sources based on semiconductor current filaments
Zutavern, Fred J.; Loubriel, Guillermo M.; Buttram, Malcolm T.; Mar, Alan; Helgeson, Wesley D.; O'Malley, Martin W.; Hjalmarson, Harold P.; Baca, Albert G.; Chow, Weng W.; Vawter, G. Allen
2003-01-01
The present invention provides a new type of semiconductor light source that can produce a high peak power output and is not injection, e-beam, or optically pumped. The present invention is capable of producing high quality coherent or incoherent optical emission. The present invention is based on current filaments, unlike conventional semiconductor lasers that are based on p-n junctions. The present invention provides a light source formed by an electron-hole plasma inside a current filament. The electron-hole plasma can be several hundred microns in diameter and several centimeters long. A current filament can be initiated optically or with an e-beam, but can be pumped electrically across a large insulating region. A current filament can be produced in high gain photoconductive semiconductor switches. The light source provided by the present invention has a potentially large volume and therefore a potentially large energy per pulse or peak power available from a single (coherent) semiconductor laser. Like other semiconductor lasers, these light sources will emit radiation at the wavelength near the bandgap energy (for GaAs 875 nm or near infra red). Immediate potential applications of the present invention include high energy, short pulse, compact, low cost lasers and other incoherent light sources.
NASA Astrophysics Data System (ADS)
Kostal, Hubert; Kreysar, Douglas; Rykowski, Ronald
2009-08-01
The color and luminance distributions of large light sources are difficult to measure because of the size of the source and the physical space required for the measurement. We describe a method for the measurement of large light sources in a limited space that efficiently overcomes the physical limitations of traditional far-field measurement techniques. This method uses a calibrated, high dynamic range imaging colorimeter and a goniometric system to move the light source through an automated measurement sequence in the imaging colorimeter's field-of-view. The measurement is performed from within the near-field of the light source, enabling a compact measurement set-up. This method generates a detailed near-field color and luminance distribution model that can be directly converted to ray sets for optical design and that can be extrapolated to far-field distributions for illumination design. The measurements obtained show excellent correlation to traditional imaging colorimeter and photogoniometer measurement methods. The near-field goniometer approach that we describe is broadly applicable to general lighting systems, can be deployed in a compact laboratory space, and provides full near-field data for optical design and simulation.
Ömeroğlu, İpek; Kaya, Esra Nur; Göksel, Meltem; Kussovski, Vesselin; Mantareva, Vanya; Durmuş, Mahmut
2017-10-15
Axially di-(alpha,alpha-diphenyl-4-pyridylmethoxy) silicon(IV) phthalocyanine (3) and its quaternized derivative (3Q) were synthesized and tested as photosensitizers against tumor and bacterial cells. These new phthalocyanines were characterized by elemental analysis, and different spectroscopic methods such as FT-IR, UV-Vis, MALDI-TOF and 1 H NMR. The photophysical properties such as absorption and fluorescence, and the photochemical properties such as singlet oxygen generation of both phthalocyanines were investigated in solutions. The obtained values were compared to the values obtained with unsubstituted silicon(IV) phthalocyanine dichloride (SiPcCl 2 ). The addition of two di-(alpha,alpha-diphenyl-4-pyridylmethanol) groups as axial ligands showed an improvement of the photophysical and photochemical properties and an increasement of the singlet oxygen quantum yield (Φ Δ ) from 0.15 to 0.33 was determined. The photodynamic efficacy of synthesized photosensitizers (3 and 3Q) were evaluated with promising photocytotoxicity (17% cell survival for 3 and 28% for 3Q) against the cervical cancer cell line (HeLa). The photodynamic inactivation of pathogenic bacterial strains Streptococcus mutans, Staphylococcus aureus, and Pseudomonas aeruginosa suggested a high susceptibility with quaternized derivative (3Q). The both Gram-positive bacterial strains were fully photoinactivated with 11μM 3Q and mild light dose 50J.cm -2 . In case of P. aeruginosa the effect was negligible for concentrations up to 22μM 3Q and light dose 100J.cm -2 . The results suggested that the novel axially substituted silicon(IV) phthalocyanines have promising characteristic as photosensitizer towards tumor cells. The quaternized derivative 3Q has high potential for photoinactivation of pathogenic bacterial species. Copyright © 2017 Elsevier Ltd. All rights reserved.
Imaging System and Method for Biomedical Analysis
2013-03-11
biological particles and items of interest. Broadly, Padmanabhan et al. utilize the diffraction of a laser light source in flow cytometry to count...spread of light from multiple LED devices over the entire sample surface. Preferably, light source 308 projects a full spectrum white light. Light...for example, red blood cells, white blood cells (which may include lymphocytes which are relatively large and easily detectable), T-helper cells
Uranium(IV) adsorption by natural organic matter in anoxic sediments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bone, Sharon E.; Dynes, James J.; Cliff, John
Uranium is an important carbon-free fuel source and environmental contaminant that accumulates in the tetravalent state, U(IV), in anoxic sediments, such as ore deposits, marine basins, and contaminated aquifers. However, little is known about the speciation of U(IV) in low-temperature geochemical environments, inhibiting the development of a conceptual model of U behavior. Until recently, U(IV) was assumed to exist predominantly as the sparingly soluble mineral uraninite (UO 2+x) in anoxic sediments; however, studies now show that this is not often the case. Yet a model of U(IV) speciation in the absence of mineral formation under field-relevant conditions has not yetmore » been developed. Uranium(IV) speciation controls its reactivity, particularly its susceptibility to oxidative mobilization, impacting its distribution and toxicity. Here we show adsorption to organic carbon and organic carbon-coated clays dominate U(IV) speciation in an organic-rich natural substrate under field-relevant conditions. Whereas previous research assumed that U(IV) speciation is dictated by the mode of reduction (i.e., whether reduction is mediated by microbes or by inorganic reductants), our results demonstrate that mineral formation can be diminished in favor of adsorption, regardless of reduction pathway. Projections of U transport and bioavailability, and thus its threat to human and ecosystem health, must consider U(IV) adsorption to organic matter within the sediment environment.« less
Uranium(IV) adsorption by natural organic matter in anoxic sediments
Bone, Sharon E.; Dynes, James J.; Cliff, John; ...
2017-01-09
Uranium is an important carbon-free fuel source and environmental contaminant that accumulates in the tetravalent state, U(IV), in anoxic sediments, such as ore deposits, marine basins, and contaminated aquifers. However, little is known about the speciation of U(IV) in low-temperature geochemical environments, inhibiting the development of a conceptual model of U behavior. Until recently, U(IV) was assumed to exist predominantly as the sparingly soluble mineral uraninite (UO 2+x) in anoxic sediments; however, studies now show that this is not often the case. Yet a model of U(IV) speciation in the absence of mineral formation under field-relevant conditions has not yetmore » been developed. Uranium(IV) speciation controls its reactivity, particularly its susceptibility to oxidative mobilization, impacting its distribution and toxicity. Here we show adsorption to organic carbon and organic carbon-coated clays dominate U(IV) speciation in an organic-rich natural substrate under field-relevant conditions. Whereas previous research assumed that U(IV) speciation is dictated by the mode of reduction (i.e., whether reduction is mediated by microbes or by inorganic reductants), our results demonstrate that mineral formation can be diminished in favor of adsorption, regardless of reduction pathway. Projections of U transport and bioavailability, and thus its threat to human and ecosystem health, must consider U(IV) adsorption to organic matter within the sediment environment.« less
Single-mode light source fabrication based on colloidal quantum dots
NASA Astrophysics Data System (ADS)
Xu, Jianfeng; Chen, Bing; Baig, Sarfaraz; Wang, Michael R.
2009-02-01
There are huge market demands for innovative, cheap and efficient light sources, including light emitting devices, such as LEDs and lasers. However, the light source development in the visible spectral range encounters significant difficulties these years. The available visible wavelength LEDs or lasers are few, large and expensive. The main challenge lies at the lack of efficient light media. Semiconductor nanocrystal quantum dots (QDs) have recently commanded considerable attention. As a result of quantum confinement effect, the emission color of these QDs covers the whole visible spectral range and can be modified dramatically by simply changing their size. Such spectral tunability, together with large photoluminescence quantum yield and photostability, make QDs attractive for potential applications in a variety of light emitting technologies. However, there are still several technical problems that hinder their application as light sources. One main issue is how to fabricate these QDs into a solid state device while still retaining their original optical emission properties. A vacuum assisted micro-fluidic fabrication of guided wave devices has demonstrated low waveguide propagation loss, lower crosstalk, and improved waveguide structures. We report herein the combination of the excellent emission properties of QDs and novel vacuum assisted micro-fluidic photonic structure fabrication technique to realize single-mode efficient light sources.
ERIC Educational Resources Information Center
Far West Lab. for Educational Research and Development, San Francisco, CA.
This report on Phase IV, of a four-phase study, provided for the development of evaluation templates and instruments to be used by the California Department of Education to facilitate systematic assessment of state funded educational technology programs and projects. These assessment documents comprised the major data collection sources for the…
NASA Technical Reports Server (NTRS)
Eck, M.; Mukunda, M.
1989-01-01
The various analyses described here were aimed at obtaining a more comprehensive understanding and definition of the environments in the vicinity of the Radioisotope Thermal Generator (RTG) during certain Space Transportation System (STS) and Titan IV launch abort accidents. Addressed here are a number of issues covering explosion environments and General Purpose Heat Source Radioisotope Thermoelectric Generator (GPHS-RTG) responses to those environments.
USDA-ARS?s Scientific Manuscript database
Most governments around the world including the USA have passed measures to phase out incandescent light bulbs in favor of more energy-efficient lighting alternatives. Research is limited on blood physiological variables of broilers grown to heavy weights (> 3 kg) under these new light sources to en...
USDA-ARS?s Scientific Manuscript database
Previous studies have investigated the interaction of different light sources and light intensity. Studies are lacking concerning the effect of different light sources and photoperiods on broiler growth and health. The results reported here are a part of a larger study to evaluate the interaction of...
Mousavinasab, Sayed Mostafa; Meyers, Ian
2011-07-01
To compare curing performance of a second generation LED curing light with a high power tungsten quartz halogen (QTH). A hybrid composite resin (Filtek Z 250, 3M, USA) was used as test material and cured using a second generation LED light (Translux Power Blue™, Heraus Kulzer ,Germany) or a very high power QTH light unit (EMS, Switzerland). A two split aluminum mold was used to prepare ten samples with LED light source cured for forty seconds and ten samples prepared using high power QTH light unit, cured for four or six seconds recommended exposure time. Hardness, depth of cure (DOC) and thermal rise during exposure time by these light sources were measured. The data submitted to analysis of variance (ANOVA), Tukey's and student's t tests at 5% significance level. Significant differences were found in hardness, DOC of samples cured by above mentioned light sources and also in thermal rises during exposure time. The curing performance of the tested QTH was not as well as the LED light. TPB light source produced the maximum hardness (81.25, 73.29, 65.49,55.83 and 24.53 for 0 mm, 1 mm, 2 mm, 3 mm and 4 mm intervals) and DOC (2.64 mm) values with forty seconds irradiation time and the high power (QTH) the least hardness (73.27, 61.51 and 31.59 for 0 mm, 1 mm and 2 mm, respectively) and DOC (2 mm) values with four seconds irradiation time. Thermal rises during 4 s and 6 s curing time using high power QTH and tested LED were 1.88°C, 3°C and 1.87°C, respectively. The used high power LED light produced greater hardness and depth of cure during forty seconds exposure time compared to high power QTH light with four or six seconds curing time. Thermal rise during 6 s curing time with QTH was greater compared to thermal changes occurred during 40 s curing time with tested LED light source. There was no difference seen in thermal changes caused by LED light with 40 s and QTH light with 4 s exposure time.
Effect of UV irradiation on the apoptosis and necrosis of Jurkat cells using UV LEDs
NASA Astrophysics Data System (ADS)
Inada, Shunko A.; Amano, Hiroshi; Akasaki, Isamu; Morita, Akimichi; Kobayashi, Keiko
2009-02-01
Phototherapy is a very effective method for treating most of the incurable skin diseases. A fluorescent light bulb is used as a conventional UV light source for this type of therapy. However, infrared radiation from the light source sometimes causes serious problems on patient's health. In addition, the normal part of the skin is irradiated when a large fluorescent light bulb is used. Moreover, a conventional UV irradiation system is heavy and has a short lifetime and a high electrical power consumption. Therefore, a new UV light source for solving the problems of phototherapy is required. To realize low-power-consumption, lightweight and long-lifetime systems, group III nitride-based UV-A1 light-emitting diodes (LEDs) were investigated. We examined the UV LED irradiation of Jurkat cell, which is a tumor cell and more sensitive to UV light than a healthy cell. The numbers of apoptotic and necrotic cells were confirmed to be the same using a UV LED and a conventional lamp system. The UV LED showed the possibility of realizing a new UV light source for phototherapy.
Datta, Saugata; Rule, Ana M; Mihalic, Jana N; Chillrud, Steve N; Bostick, Benjamin C.; Ramos-Bonilla, Juan P; Han, Inkyu; Polyak, Lisa M; Geyh, Alison S; Breysse, Patrick N
2012-01-01
The purpose of this study is to characterize manganese oxidation states and speciation in airborne particulate matter (PM), and describe how these potentially important determinants of PM toxicity vary by location. Ambient PM samples were collected from five counties across the US using a high volume sequential cyclone system that collects PM in dry bulk form segregated into “coarse” and “fine” size fractions. The fine fraction was analyzed for this study. Analyses included total Mn using ICP-MS, and characterization of oxidation states and speciation using X-ray Absorption Spectroscopy (XAS). XAS spectra of all samples and ten standard compounds of Mn were obtained at the National Synchrotron Light Source. XAS data was analyzed using Linear Combination Fitting (LCF). Results of the LCF analysis describe differences in composition between samples. Mn(II) acetate and Mn(II) oxide are present in all samples, while Mn(II) carbonate and Mn(IV) oxide are absent. To the best of our knowledge, this is the first paper to characterize Mn composition of ambient PM and examine differences between urban sites in the US. Differences in oxidation state and composition indicate regional variations in sources and atmospheric chemistry that may help explain differences in health effects identified in epidemiological studies. PMID:22309075
Effects of type of light on mouse circadian behaviour and stress levels.
Alves-Simoes, Marta; Coleman, Georgia; Canal, Maria Mercè
2016-02-01
Light is the principal synchronizing environmental factor for the biological clock. Light quantity (intensity), and light quality (type of light source) can have different effects. The aim of this study was to determine the effects of the type of light experienced from the time of birth on mouse growth, circadian behaviour and stress levels. We raised pigmented and albino mice under 24 h light-dark cycles of either fluorescent or white light-emitting diode (LED) light source during the suckling stage, and the animals were then exposed to various light environments after weaning and their growth rate, locomotor activity and plasma corticosterone concentration were measured. We found that the type of light the animals were exposed to did not affect the animals' growth rates or stress levels. However, we observed significant effects on the expression of the locomotor activity rhythm under low contrast light-dark cycles in pigmented mice, and under constant light in both albino and pigmented mice. These results highlight the importance of environmental light quality (light source) on circadian behavioural rhythms, and the need for close monitoring of light environments in animal facilities. © The Author(s) 2015.
Revision to Planetary Protection Policy for Mars Missions
NASA Technical Reports Server (NTRS)
DeVincenzi, D. L.; Stabekis, P.; Barengoltz, J.; Morrison, David (Technical Monitor)
1994-01-01
Under existing COSPAR policy adopted in 1984, missions to Mars (landers, probes, and some orbiters) are designated as Category IV missions. As such, the procedures for implementing planetary protection requirements could include trajectory biasing, cleanrooms, bioload reduction, sterilization of hardware, and bioshields, i. e. requirements could be similar to Viking. However, in 1992, a U. S. National Academy of Sciences study recommended that controls on forward contamination of Mars be tied to specific mission objectives. The report recommended that Mars landers with life detection instruments be subject to at least Viking-level sterilization procedures for bioload reduction, while spacecraft (including orbiters) without life detection instruments be subject to at least Viking-level pre sterilization procedures for bioload reduction but need not be sterilized. In light of this, it is proposed that the current policy's Category IV missions and their planetary protection requirements be divided into two subcategories as follows: Category IV A, for missions comprising landers and probes without life detection experiments and some orbiters, which will meet a specified bioburden limit for exposed surfaces; Category IV B, for landers and probes with life detection experiments, which will require complete system sterilization. For Category IV A missions, bioburden specifications will be proposed and implementing procedures discussed. A resolution will be proposed to modify the existing COSPAR policy to reflect these changes. Similar specifications, procedures, and resolution for Category IV B missions will be the subject of a later study.
Andreatta, Lígia Maria Lima; Furuse, Adilson Yoshio; Prakki, Anuradha; Bombonatti, Juliana Fraga Soares; Mondelli, Rafael Francisco Lia
2016-01-01
The aim of the present in vitro study was to evaluate the temperature variation inside the pulp chamber during light-activation of the adhesive and resin composite layers with different light sources. Cavities measuring 8x10 mm were prepared on the buccal surface of bovine incisors, leaving a remaining dentin thickness of 1 mm. Specimens were placed in a 37±1 °C water bath to standardize the temperature. The temperature in the pulp chamber was measured every 10 s during 40 s of light activation of the adhesive system (SBMP-3M/ESPE) and in the three consecutive 1-mm-thick layers of resin composite (Z250-3M/ESPE). Three light source devices were evaluated: Elipar 2500 (QTH), LD Max (LED low irradiance) and VALO (LED high irradiance). The results were submitted to one-way ANOVA with repeated measures and Tukey's test, both with p<0.001. The exothermic reaction warming was observed in the Z250 increments, but not in the SBMP. The high irradiance LED showed a higher temperature average (42.7±1.56 °C), followed by the quartz-tungsten-halogen light (40.6±0.67 °C) and the lower irradiance LED (37.8±0.12 °C). Higher temperature increases were observed with the adhesive and the first resin composite increment light-activation, regardless of the employed light source. From the second increment of Z250, the restorative material acted as a dispersive structure of heat, reducing temperature increases. Regardless the light source and restorative step, the temperature increased with the irradiation time. It may be concluded that the light source, irradiation time and resin composite thickness interfered in the temperature variation inside the pulp chamber.
Source positions from VLBI combined solution
NASA Astrophysics Data System (ADS)
Bachmann, S.; Thaller, D.; Engelhardt, G.
2014-12-01
The IVS Combination Center at BKG is primarily responsible for combined Earth Orientation Parameter (EOP) products and the generation of a terrestrial reference frame based on VLBI observations (VTRF). The procedure is based on the combination of normal equations provided by six IVS Analysis Centers (AC). Since more and more ACs also provide source positions in the normal equations - beside EOPs and station coordinates - an estimation of these parameters is possible and should be investigated. In the past, the International Celestial Reference Frame (ICRF) was not generated as a combined solution from several individual solutions, but was based on a single solution provided by one AC. The presentation will give an overview on the combination strategy and the possibilities for combined source position determination. This includes comparisons with existing catalogs, quality estimation and possibilities of rigorous combination of EOP, TRF and CRF in one combination process.
Near-field photometry for organic light-emitting diodes
NASA Astrophysics Data System (ADS)
Li, Rui; Harikumar, Krishnan; Isphording, Alexandar; Venkataramanan, Venkat
2013-03-01
Organic Light Emitting Diode (OLED) technology is rapidly maturing to be ready for next generation of light source for general lighting. The current standard test methods for solid state lighting have evolved for semiconductor sources, with point-like emission characteristics. However, OLED devices are extended surface emitters, where spatial uniformity and angular variation of brightness and colour are important. This necessitates advanced test methods to obtain meaningful data for fundamental understanding, lighting product development and deployment. In this work, a near field imaging goniophotometer was used to characterize lighting-class white OLED devices, where luminance and colour information of the pixels on the light sources were measured at a near field distance for various angles. Analysis was performed to obtain angle dependent luminous intensity, CIE chromaticity coordinates and correlated colour temperature (CCT) in the far field. Furthermore, a complete ray set with chromaticity information was generated, so that illuminance at any distance and angle from the light source can be determined. The generated ray set is needed for optical modeling and design of OLED luminaires. Our results show that luminance non-uniformity could potentially affect the luminaire aesthetics and CCT can vary with angle by more than 2000K. This leads to the same source being perceived as warm or cool depending on the viewing angle. As OLEDs are becoming commercially available, this could be a major challenge for lighting designers. Near field measurement can provide detailed specifications and quantitative comparison between OLED products for performance improvement.
NASA Astrophysics Data System (ADS)
Vaudelle, Fabrice; L'Huillier, Jean-Pierre; Askoura, Mohamed Lamine
2017-06-01
Red and near-Infrared light is often used as a useful diagnostic and imaging probe for highly scattering media such as biological tissues, fruits and vegetables. Part of diffusively reflected light gives interesting information related to the tissue subsurface, whereas light recorded at further distances may probe deeper into the interrogated turbid tissues. However, modelling diffusive events occurring at short source-detector distances requires to consider both the distribution of the light sources and the scattering phase functions. In this report, a modified Monte Carlo model is used to compute light transport in curved and multi-layered tissue samples which are covered with a thin and highly diffusing tissue layer. Different light source distributions (ballistic, diffuse or Lambertian) are tested with specific scattering phase functions (modified or not modified Henyey-Greenstein, Gegenbauer and Mie) to compute the amount of backscattered and transmitted light in apple and human skin structures. Comparisons between simulation results and experiments carried out with a multispectral imaging setup confirm the soundness of the theoretical strategy and may explain the role of the skin on light transport in whole and half-cut apples. Other computational results show that a Lambertian source distribution combined with a Henyey-Greenstein phase function provides a higher photon density in the stratum corneum than in the upper dermis layer. Furthermore, it is also shown that the scattering phase function may affect the shape and the magnitude of the Bidirectional Reflectance Distribution (BRDF) exhibited at the skin surface.
40 CFR 1027.105 - How much are the fees?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 1027.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION... (ii) Light-duty vehicles and trucks California-only 16,944 (iii) Medium-duty passenger vehicles Federal 33,883 (iv) Medium-duty passenger vehicles California-only 16,944 (v) Highway motorcycle All 2,414...
40 CFR 1027.105 - How much are the fees?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 1027.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION... (ii) Light-duty vehicles and trucks California-only 16,944 (iii) Medium-duty passenger vehicles Federal 33,883 (iv) Medium-duty passenger vehicles California-only 16,944 (v) Highway motorcycle All 2,414...
40 CFR 1027.105 - How much are the fees?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 1027.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION... (ii) Light-duty vehicles and trucks California-only 16,944 (iii) Medium-duty passenger vehicles Federal 33,883 (iv) Medium-duty passenger vehicles California-only 16,944 (v) Highway motorcycle All 2,414...
40 CFR 1027.105 - How much are the fees?
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 1027.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION... (ii) Light-duty vehicles and trucks California-only 16,944 (iii) Medium-duty passenger vehicles Federal 33,883 (iv) Medium-duty passenger vehicles California-only 16,944 (v) Highway motorcycle All 2,414...
33 CFR 106.265 - Security measures for restricted areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Telecommunications; (iii) Power distribution system; (iv) Access points for ventilation and air-conditioning systems... security areas within the OCS facility; (6) Protect security and surveillance equipment and systems; and (7... security and surveillance equipment and systems and their controls, and lighting system controls; and (3...
DOT National Transportation Integrated Search
1981-10-01
This report presents an updated description of a vehicle simulation program, VEHSIM, which can determine the fuel economy and performance of a specified vehicle over a defined route as it executes a given driving schedule. Vehicle input accommodated ...
Translations on USSR Science and Technology, Physical Sciences and Technology, No. 25
1977-12-07
PORTRAN-II; FORTRAN -IV; and ALGOL-60 dialect. BASIC language may be used when solving problems in the interactive mode (the stages of...transmissions and broadcasts. Materials from foreign-language sources are translated; those from English-language sources are transcribed or reprinted, with... source . Times within items are as given by source . The contents of this publication in no way represent the poli- cies, views or attitudes of the U.S
Physical Properties of the X-Ray-Luminous SN 1978K in NGC 1313 from Multiwavelength Observations
NASA Astrophysics Data System (ADS)
Schlegel, Eric M.; Ryder, Stuart; Staveley-Smith, L.; Petre, R.; Colbert, E.; Dopita, M.; Campbell-Wilson, D.
1999-12-01
We update the light curves from the X-ray, optical, and radio bandpasses which we have assembled over the past decade and present two observations in the ultraviolet using the Hubble Space Telescope Faint Object Spectrograph. The HRI X-ray light curve is constant within the errors over the entire observation period. This behavior is confirmed in the ASCA GIS data obtained in 1993 and 1995. In the ultraviolet, we detected Lyα, the [Ne IV] 2422/2424 Å doublet, the Mg II doublet at 2800 Å, and a line at approximately 3190 Å that we attribute to He I 3187. Only the Mg II and He I lines are detected at SN 1978K's position. The optical light curve is formally constant within the errors, although a slight upward trend may be present. The radio light curve continues its steep decline. The longer time span of our radio observations compared to previous studies shows that SN 1978K is in the same class of highly X-ray and radio-luminous supernovae as SN 1986J and SN 1988Z. The [Ne IV] emission is spatially distant from the location of SN 1978K and originates in the preshocked matter. The Mg II doublet flux ratio implies the quantity of line optical depth times density of approximately 1014 cm-3 for its emission region. The emission site must lie in the shocked gas.
Lask, Gary; Fournier, Nathalie; Trelles, Mario; Elman, Monica; Scheflan, Michael; Slatkine, Michael; Naimark, Jenny; Harth, Yoram
2005-12-01
A major cause of skin aging is a chronic micro-inflammation triggered by UV radiation and external pollutants. It has been demonstrated that blue light diminishes inflammatory conditions and near infrared light enhances circulation. To assess the effectiveness of a non thermal dual wavelength -- blue (405 - 420 nm) and near infrared (850 - 900 nm) -- light source in skin rejuvenation, in the reduction of the duration of post skin resurfacing erythema and in the acceleration of healing of post surgical conditions (face lift and breast augmentation). We have utilized a non contact, hand free dual wavelength light source (iClearXL and Clear100XL, Curelight Ltd) to treat over 60 patients and perform three controlled studies in four centers. Follow up duration was three months. Control group for photo-rejuvenation consisted of patients treated with Glycolic peeling and daily appliance of vitamin C Control group for post skin resurfacing erythema duration consisted of patients untreated by the light source and control group for post surgical healing consisted of patients untreated by the light source or treated by the light source on one side only. Post skin resurfacing erythema duration is reduced by 90%. The healing of post surgical conditions is substantially accelerated and discomfort is reduced. The anti aging effect of the light source includes: reduction of pore size in 90% of patients with stable results at three months follow up, enhanced skin radiance in 90% of patients with stable results at three months follow up and smoothing of fine wrinkles in 45% of patients with stable results at three months follow up. The control group showed poor results which were stable for a duration of less than one month. A non thermal, non contact / hand free light source emitting at 405-420 nm and 850-900 nm considerably enhances aesthetic and surgical aesthetic procedures without consuming user time.
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Sharma, Rajdeep
2013-12-10
Lighting system having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr, Charles Franklin; Sharma, Rajdeep
2016-08-30
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
Lighting system with thermal management system having point contact synthetic jets
Arik, Mehmet; Weaver, Stanton Earl; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Sharma, Rajdeep
2016-08-23
Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.
NASA Astrophysics Data System (ADS)
Hirai, Hiroaki; Kitaya, Yoshiaki; Hirai, Takehiro
A fundamental study was conducted to establish an experimental system for space farming. Since to ensure optimal light for plant cultivation in space is of grave importance, this study examined the performance of light sources and radiation sensors under microgravity conditions created during the parabolic airplane flight. Three kinds of light sources, a halogen bulb, a fluorescent tube, and blue and red LEDs, and ten models of radiation sensors available in the market were used for the experiment. Surface temperature of the light sources, output signals from the radiation sensors, spectroscopic characteristics were measured at the gravity levels of 0.01, 1.0 and 1.8 G for 20 seconds each during parabolic airplane flights. As a result, the performance of the halogen lamp was affected the most by the gravity level among the three light sources. Under the microgravity conditions which do not raise heat convection, the temperature of the halogen lamp rose and the output of the radiation sensors increased. Spectral distributions of the halogen lamp indicated that peak wavelength appeared the highest at the level of 0.01G, which contributed to the increase in light intensity. In the case of red and blue LEDs, which are promising light sources in space farming, the temperature of both LED chips rose but irradiance from red LED increased and that from blue LED decreased under microgravity conditions due to the different thermal characteristics.
Implementing the UCSD PASCAL system on the MODCOMP computer. [deep space network
NASA Technical Reports Server (NTRS)
Wolfe, T.
1980-01-01
The implementation of an interactive software development system (UCSD PASCAL) on the MODCOMP computer is discussed. The development of an interpreter for the MODCOMP II and the MODCOMP IV computers, written in MODCOMP II assembly language, is described. The complete Pascal programming system was run successfully on a MODCOMP II and MODCOMP IV under both the MAX II/III and MAX IV operating systems. The source code for an 8080 microcomputer version of the interpreter was used as the design for the MODCOMP interpreter. A mapping of the functions within the 8080 interpreter into MODCOMP II assembly language was the method used to code the interpreter.
Transversely polarized source cladding for an optical fiber
NASA Technical Reports Server (NTRS)
Egalon, Claudio Oliveira (Inventor); Rogowski, Robert S. (Inventor)
1994-01-01
An optical fiber comprising a fiber core having a longitudinal symmetry axis is provided. An active cladding surrounds a portion of the fiber core and comprises light-producing sources which emit light in response to chemical or light excitation. The cladding sources are oriented transversely with respect to the longitudinal axis of the fiber core. This polarization results in a superior power efficiency compared to active cladding sources that are randomly polarized or longitudinally polarized parallel with the longitudinal symmetry axis.
A 2007 photometric study and UV spectral analysis of the Wolf-Rayet binary V444 Cyg
NASA Astrophysics Data System (ADS)
Eriş, F. Z.; Ekmekçi, F.
2011-07-01
Photometric and spectroscopic characteristics of the WN5+O6 binary system, V444 Cyg, were studied. The Wilson-Devinney (WD) analysis, using new BV observations carried out at the Ankara University Observatory, revealed the masses, radii, and temperatures of the components of the system as MWR=10.64 M⊙, MO=24.68 M⊙, RWR=7.19 R⊙, RO=6.85 R⊙, TWR=31 000 K, and TO=40 000 K , respectively. It was found that both components had a full spherical geometry, whereas the circumstellar envelope of the WR component had an asymmetric structure. The O-C analysis of the system revealed a period lengthening of 0.139±0.018 s yr-1, implying a mass loss rate of (6.76 ± 0.39) × 10-6 M⊙ yr-1 for the WR component. Moreover, 106 IUE-NEWSIPS spectra were obtained from NASA's IUE archive for line identification and determination of line profile variability with phase, wind velocities and variability in continuum fluxes. The integrated continuum flux level (between 1200-2000 \\rA) showed a mild and regular increase from orbital phase 0.00 up to 0.50 and then a decrease in the same way back to phase 0.00. This is evaluated as the O component making a constant and regular contribution to the system's UV light as the dominant source. The C IV line, originating in the circumstellar envelope, had the highest velocity while N IV line, originating in deeper layers of the envelope, had the lowest velocity. The average radial velocity calculated by using the C IV line (wind velocity) was found as 2326 km s-1. Tables 2 and 3 and Figs. 4 and 8 are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr or via http:://cdsweb.u-strasbg.fr/AN/332/616
NASA Astrophysics Data System (ADS)
Sogabe, Tomah; Ogura, Akio; Hung, Chao-Yu; Evstropov, Valery; Mintairov, Mikhail; Shvarts, Maxim; Okada, Yoshitaka
2013-12-01
In this paper, we focused on developing an accurate model to describe the luminescent coupling (L-C) effect in multijunction solar cells (MJSC) under light concentration. We present here a transcend current-voltage (I-V) formula combined with a self-consistent simulation algorithm to derive the coupling yield γ dependence on light intensity by including the electrical parameters such as shunt resistance (Rsh) and series resistance (Rs), which were ignored in previous simulation models. The effects of both Rsh and Rs on γ were revealed, and the dependence of γ on the external voltage bias Vbias was investigated. Meanwhile, we have performed experiments to determine coupling yield γ by measuring the I-V curves of individual subcell of InGaP/GaAs/Ge triple junction solar cell under varied light intensity. We found that the measured results are only in good agreement with the simulated data obtained from the model where the resistance parameters were included. Based on these results, we calculated the conversion efficiency of MJSC and found that the efficiency increase due to L-C effect is 0.31% under 1 sun and 1.07% under 1000 suns. Thus the L-C analysis results presented here will work as an additional device optimization criteria for MJSC toward higher efficiency.
Mitchell, V; Sigala, J; Ballot, C; Jumeau, F; Barbotin, A L; Duhamel, A; Rives, N; Rigot, J M; Escalier, D; Peers, M C
2015-03-01
Although electron microscopy provides a detailed analysis of ultrastructural abnormalities, this technique is not available in all laboratories. We sought to determine whether certain characteristics of the flagellum as assessed by light microscopy were related to axonemal abnormalities. Forty-one patients with an absence of outer dynein arms (type I), a lack of a central complex (type III) and an absence of peripheral doublets (type IV) were studied. Sperm morphology was scored according to David's modified classification. Flagella with an irregular thickness were classified as being of normal length, short or broken. There were correlations between missing outer dynein arms and abnormal, short or coiled flagellum. Type III patients showed the highest flagellar defects (a short (P = 0.0027) or an absent flagellum (P = 0.011)). Just over 68% of the irregular flagella were short in Type III patients, whereas this value was only 34.5% in type I and 26.4% in type IV (P = 0.002). There was a negative correlation between misassembly and spermatozoa of irregular flagella (r = -0.79; P = 0.019). It is concluded that light microscopy analysis of flagellum abnormalities may help provide a correct diagnosis, identify sperm abnormalities with fertility potentials and outcomes in assisted reproduction technologies and assess the genetic risk. © 2014 Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
Zissis, Georges; Haverlag, Marco
2010-06-01
Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from high to low pressure and dielectric barrier lamps, from breakdown to acoustic resonance. Especially in the domain of high pressure lamps, J J Curry shows how coherent and incoherent x-ray scattering can be used as an imaging technique adapted to lamps. J Hirsch et al treat the acoustic resonance phenomenon that seriously limits the frequency domain for high pressure lamp operation. M Jinno et al illustrate a method that allows for measuring Xe buffer gas pressure in Hg-free metal halide lamps for automotive applications. In the domain of low pressure lamps, M Gendre et al investigate the breakdown phase by means of optical and electrical diagnostic tools. The similarity rules used a long time ago for simulating plasma behaviour based on invariants are now serving as diagnostic tools, as shown in the paper by D Michael et al. N Dagang et al show how impurities can be detected in Hg-free electrodeless lamps and more particularly in dielectric barrier discharges emitting excimer radiation. The quality of light is illustrated by a final example by R Kozakov et al on how to qualify the light output from the lamp with respect to biological effects on humans.
Optical sensor of magnetic fields
Butler, M.A.; Martin, S.J.
1986-03-25
An optical magnetic field strength sensor for measuring the field strength of a magnetic field comprising a dilute magnetic semi-conductor probe having first and second ends, longitudinally positioned in the magnetic field for providing Faraday polarization rotation of light passing therethrough relative to the strength of the magnetic field. Light provided by a remote light source is propagated through an optical fiber coupler and a single optical fiber strand between the probe and the light source for providing a light path therebetween. A polarizer and an apparatus for rotating the polarization of the light is provided in the light path and a reflector is carried by the second end of the probe for reflecting the light back through the probe and thence through the polarizer to the optical coupler. A photo detector apparatus is operably connected to the optical coupler for detecting and measuring the intensity of the reflected light and comparing same to the light source intensity whereby the magnetic field strength may be calculated.
NASA Astrophysics Data System (ADS)
Lee, Dicky; Moulton, Peter F.
2001-03-01
In this paper we discuss our red, green, and blue (RGB) optical parametric oscillator (OPO) light source for projection display applications. Our source consists of a diode-pumped pump laser and a LBO-based OPO. Based on our Nd:YLF gain-module design, the pump laser is frequency doubled to serve as the pump source for the OPO. The unconverted pump power is recycled as the green light for projection. The singly resonant, non-critically phase- matched OPO has, to date, generated 13 W of 898-nm signal power and an estimated 9.3 W of intra-cavity idler power at 1256 nm. With approximately 76% of pump depletion, the power of the residual green light for projection is about 5.8 W. We have extra-cavity doubled the signal to produce approximately 3.5 W of 449-nm blue light and intra-cavity doubled the idler to produce approximately 6 W of 628-nm red light. The OPO-based RGB source generates about 4000 lumens of D65-balanced white light. The overall electrical power luminous efficiency (diodes only) is about 14.6 lumens/Watt.
40 CFR 63.1321 - Batch process vents provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1321 Batch process vents..., owners and operators of new and existing affected sources with batch process vents shall comply with the... applicable reporting requirements in § 63.1327. (b) New SAN batch affected sources. Owners and operators of...
2016-04-01
Sanitation, and Hygiene WFP World Food Programme WHO World Health Organization Unclassified Unclassified xii This page intentionally left blank...Insurgency Natural Disaster Contamination Visibility Disposition Distribution Sourcing Prioritization Security Financial U.S. Military Services Combatant...supply; restrictions on sourcing; contamination concerns (IV solutions) Small in size; multiple variants with limited interchangeability; requires
40 CFR 63.1320 - PET and polystyrene affected sources-reporting provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers... with § 63.1316 by demonstrating that mass emissions per mass product are less than or equal to the...
Validation of luminescent source reconstruction using spectrally resolved bioluminescence images
NASA Astrophysics Data System (ADS)
Virostko, John M.; Powers, Alvin C.; Jansen, E. D.
2008-02-01
This study examines the accuracy of the Living Image® Software 3D Analysis Package (Xenogen, Alameda, CA) in reconstruction of light source depth and intensity. Constant intensity light sources were placed in an optically homogeneous medium (chicken breast). Spectrally filtered images were taken at 560, 580, 600, 620, 640, and 660 nanometers. The Living Image® Software 3D Analysis Package was employed to reconstruct source depth and intensity using these spectrally filtered images. For sources shallower than the mean free path of light there was proportionally higher inaccuracy in reconstruction. For sources deeper than the mean free path, the average error in depth and intensity reconstruction was less than 4% and 12%, respectively. The ability to distinguish multiple sources decreased with increasing source depth and typically required a spatial separation of twice the depth. The constant intensity light sources were also implanted in mice to examine the effect of optical inhomogeneity. The reconstruction accuracy suffered in inhomogeneous tissue with accuracy influenced by the choice of optical properties used in reconstruction.
Mendoza, S M; van Heugten, E
2014-02-01
Acidulated fats and oils are by-products of the fat-refining industry. They contain high levels of FFA and are 10% to 20% less expensive than refined fats and oils. Two studies were designed to measure the effects of dietary lipid sources low or high in FFA on growth performance and apparent total tract digestibility (ATTD) of lipids and GE in nursery pigs. In Exp. 1, 189 pigs at 14 d postweaning (BW of 9.32 ± 0.11 kg) were used for 21 d with 9 replicate pens per treatment and 3 pigs per pen. Dietary treatments consisted of a control diet without added lipids and 6 diets with 6% inclusion of lipids. Four lipid sources were combined to create the dietary treatments with 2 levels of FFA (0.40% or 54.0%) and 3 degrees of fat saturation (iodine value [IV] = 77, 100, or 123) in a 2 × 3 factorial arrangement. Lipid sources were soybean oil (0.3% FFA and IV = 129.4), soybean-cottonseed acid oil blend (70.5% FFA and IV = 112.9), choice white grease (0.6% FFA and IV = 74.8), and choice white acid grease (56.0% FFA and IV = 79.0). Addition of lipid sources decreased ADFI (810 vs. 872 g/d; P = 0.018) and improved G:F (716 vs. 646 g/kg; P < 0.001). Diets high in FFA tended (P = 0.08) to improve final BW (21.35 vs. 21.01 kg) and ADG (576 vs. 560 g/d). Lipid-supplemented diets had greater ATTD of lipids than control diets (67.4% vs. 29.7%; P < 0.001). Apparent total tract digestibility of lipids was greater in diets with low FFA (69.9% vs. 64.9%; P < 0.001) and decreased linearly with increasing IV (73.2%, 69.1%, and 67.2%). For GE, ATTD was greater in diets with low FFA (83.1% vs. 80.9%; P = 0.001). In Exp. 2, 252 pigs at 7 d postweaning (BW of 7.0 ± 0.2 kg) were used for 28 d with 9 replicate pens per treatment and 4 pigs per pen. Diets included a control diet without added lipids and 6 treatments with 2.5%, 5.0%, or 7.5% of lipids from either poultry fat (1.9% FFA) or acidulated poultry fat (37.8% FFA) in a 2 × 3 factorial arrangement. Addition of lipids increased (P < 0.001) final BW (19.9 vs. 18.4 kg) and ADG (460 vs. 405 g/d) regardless of source. Fat increased (P < 0.001) ADFI when added at 2.5% and then decreased ADFI with each further increment (663, 740, 681, and 653 g for 0%, 2.5%, 5.0%, and 7.5% fat, respectively). Inclusion of lipids linearly (P < 0.001) improved G:F (615, 615, 688, and 692 g/kg for 0%, 2.5%, 5.0%, and 7.5% fat, respectively) and ATTD of lipids (17.8%, 50.2%, 71.0%, and 77.3% for 0, 2.5, 5.0, and 7.5% fat, respectively) and GE (76.1%, 76.4%, 83.3%, and 84.4% for 0%, 2.5%, 5.0%, and 7.5% fat, respectively). Acidulated lipids resulted in similar performance compared with refined lipids and could be economical alternatives to more expensive lipid sources.
Early, James W.; Lester, Charles S.
2003-01-01
In the apparatus of the invention, a first excitation laser or other excitation light source is used in tandem with an ignitor laser to provide a compact, durable, engine deployable fuel ignition laser system. Reliable fuel ignition is provided over a wide range of fuel conditions by using a single remote excitation light source for one or more small lasers located proximate to one or more fuel combustion zones. In a third embodiment, alternating short and long pulses of light from the excitation light source are directed into the ignitor laser. Each of the embodiments of the invention can be multiplexed so as to provide laser light energy sequentially to more than one ignitor laser.
3-D simulation of nanopore structure for DNA sequencing.
Park, Jun-Mo; Pak, Y Eugene; Chun, Honggu; Lee, Jong-Ho
2012-07-01
In this paper, we propose a method for simulating nanopore structure by using conventional 3-D simulation tool to mimic the I-V behavior of the nanopore structure. In the simulation, we use lightly doped silicon for ionic solution where some parameters like electron affinity and dielectric constant are fitted to consider the ionic solution. By using this method, we can simulate the I-V behavior of nanopore structure depending on the location and the size of the sphere shaped silicon oxide which is considered to be an indicator of a DNA base. In addition, we simulate an Ionic Field Effect Transistor (IFET) which has basically the nanopore structure, and show that the simulated curves follow sufficiently the I-V behavior of the measurement data. Therefore, we think it is reasonable to apply parameter modeling mentioned above to simulate nanopore structure. The key idea is to modify electron affinity of silicon which is used to mimic the KCl solution to avoid band bending and depletion inside the nanopore. We could efficiently utilize conventional 3-D simulation tool to simulate the I-V behavior of nanopore structures.
The anomalous C 4 intensity ratio in symbiotic stars
NASA Technical Reports Server (NTRS)
Michalitsianos, A. G.; Kafatos, M.; Fahey, R. P.
1988-01-01
The C IV lambda lambda 1548.2,1550.8 resonance doublet in a symbiotic stars was shown to exhibit anomalous line intensity ratios in which I (lambda 1548.2)/I(lambda 1550.8) less than 1, or less than the optically-thick limit of unity. The R Aquarii-central HII region and RX Puppis exhibit this phenomena. The I(lambda 1548.2)/I(lambda 1550.8) ratio in RX Puppis is found to vary inversely with the total C IV line intensity, and with the FES-visual light, as the object declined over a 5 yr period following a brightening in UV and optical emission which peaked in 1982. This doublet intensity behavior could be explained by a wind which has a narrow velocity range of 600 approx. less than sup v wind approx. less than 1000 km/sec, or by the pumping of the Fe II (mul. 45.01) transition a sup 4 F sub 9/2 - y sup 4 H(o) sub 11/2 by C IV lambda 1548.2, which effectively scatters C IV photons into the Fe II spectrum in these objects.
New Directions in X-Ray Light Sources
Falcone, Roger
2017-12-09
July 15, 2008 Berkeley Lab lecture: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.
White LED sources for vehicle forward lighting
NASA Astrophysics Data System (ADS)
Van Derlofske, John F.; McColgan, Michele W.
2002-11-01
Considerations for the use of white light emitting diode (LED) sources to produce illumination for automotive forward lighting is presented. Due to their reliability, small size, lower consumption, and lower heat generation LEDs are a natural choice for automotive lighting systems. Currently, LEDs are being sucessfully employed in most vehicle lighting applications. In these applications the light levels, distributions, and colors needed are achievable by present LED technologies. However, for vehicle white light illumination applications LEDs are now only being considered for low light level applications, such as back-up lamps. This is due to the relatively low lumen output that has been available up to now in white LEDs. With the advent of new higher lumen packages, and with the promise of even higher light output in the near future, the use of white LEDs sources for all vehicle forward lighting applications is beginning to be considered. Through computer modeling and photometric evaluation this paper examines the possibilities of using currently available white LED technology for vehicle headlamps. It is apparent that optimal LED sources for vehicle forward lighting applications will be constructed with hereto undeveloped technology and packaging configurations. However, the intent here in exploring currently available products is to begin the discussion on the design possibilities and significant issues surrounding LEDs in order to aid in the design and development of future LED sources and systems. Considerations such as total light output, physical size, optical control, power consumption, color appearance, and the effects of white LED spectra on glare and peripheral vision are explored. Finally, conclusions of the feasibility of current LED technology being used in these applications and recommendations of technology advancements that may need to occur are made.
Lighting system with heat distribution face plate
Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri
2013-09-10
Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.
Stability of Levothyroxine in Sodium Chloride for IV Administration.
Strong, Dawn K; Decarie, Diane; Ensom, Mary H H
2010-11-01
Levothyroxine by IV administration is often prescribed in the intensive care unit for the management of potential solid organ donors, following declaration of brain death and provision of consent for organ donation. Published data on the stability of levothyroxine in IV solutions are limited. To evaluate the physical compatibility and chemical stability, over a 24-h period, of 2 concentrations of levothyroxine in 0.9% sodium chloride with storage at room temperature and with exposure to or protection from light. Levothyroxine solutions (0.4 μg/mL and 2.0 μg/mL) were prepared in 50-mL minibags of 0.9% NaCl and stored at room temperature (25°C) with exposure to or protection from light. Samples were collected from each minibag at time 0 and after 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 8.0, 12.0, and 24.0 h. The samples were analyzed in triplicate with a validated stability-indicating high-performance liquid chromatography method using ultraviolet detection. A solution was considered stable if it maintained 90% of its initial concentration of levothyroxine. Changes in colour, clarity, and pH were assessed to determine the physical compatibility of the solutions. All samples remained clear, colourless, and free of precipitate throughout the study, and there were no significant changes in pH. Based on the 95% confidence interval of the slope of the curve relating concentration to time determined by linear regression, solutions of levothyroxine with concentration 0.4 μg/mL would maintain at least 90% of the initial concentration for 16.9 h with exposure to light and for 18.0 h if kept in the dark. Solutions of levothyroxine with concentration 2.0 μg/mL would maintain at least 90% of the initial concentration for 6.5 h with exposure to light and for 12.0 h if kept in the dark, with 95% confidence. Extemporaneously prepared solutions of levothyroxine in 0.9% NaCl can be expected to remain stable for at least 6.5 h if stored without protection from light and at least 12 h if stored in the dark. Stability is related to concentration, with more dilute solutions having greater stability.
Large area, surface discharge pumped, vacuum ultraviolet light source
Sze, Robert C.; Quigley, Gerard P.
1996-01-01
Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source. A contamination-free VUV light source having a 225 cm.sup.2 emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm.sup.2 at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing.
Direction-division multiplexed holographic free-electron-driven light sources
NASA Astrophysics Data System (ADS)
Clarke, Brendan P.; MacDonald, Kevin F.; Zheludev, Nikolay I.
2018-01-01
We report on a free-electron-driven light source with a controllable direction of emission. The source comprises a microscopic array of plasmonic surface-relief holographic domains, each tailored to direct electron-induced light emission at a selected wavelength into a collimated beam in a prescribed direction. The direction-division multiplexed source is tested by driving it with the 30 kV electron beam of a scanning electron microscope: light emission, at a wavelength of 800 nm in the present case, is switched among different output angles by micron-scale repositioning of the electron injection point among domains. Such sources, with directional switching/tuning possible at picosecond timescales, may be applied to field-emission and surface-conduction electron-emission display technologies, optical multiplexing, and charged-particle-beam position metrology.
Passivation of quartz for halogen-containing light sources
Falkenstein, Zoran
1999-01-01
Lifetime of halogen containing VUV, UV, visible or IR light sources can be extended by passivating the quartz or glass gas containers with halogens prior to filling the quartz with the halogen and rare gas mixtures used to produce the light.
Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements
NASA Astrophysics Data System (ADS)
Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey
2017-12-01
Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.
Nonimaging Optical Illumination System
Winston, Roland
1994-02-22
A nonimaging illumination or concentration optical device. An optical device is provided having a light source, a light reflecting surface with an opening and positioned partially around the light source which is opposite the opening of the light reflecting surface. The light reflecting surface is disposed to produce a substantially uniform intensity output with the reflecting surface defined in terms of a radius vector R.sub.i in conjunction with an angle .phi..sub.i between R.sub.i, a direction from the source and an angle .theta..sub.i between direct forward illumination and the light ray reflected once from the reflecting surface. R.sub.i varies as the exponential of tan (.phi..sub.i -.theta..sub.i)/2 integrated over .phi..sub.i.
Color-tunable lighting devices and methods of use
Davis, James Lynn
2017-02-07
A lighting device (100) includes a housing (104) enclosing a housing interior (108), a light source (132), a light converter (136), and a color tuning device. The light source is configured for emitting a primary light beam of a primary wavelength (140) through the housing interior. The light converter includes a luminescent material (144) facing the housing interior and configured for emitting secondary light (156, 158) of one or more wavelengths different from the primary wavelength, in response to excitation by the primary light beam. The housing includes a light exit (124) for outputting a combination of primary light and secondary light. The color tuning device is configured for adjusting a position of the primary light beam relative to the luminescent material.
Apparatus and method for measuring the thickness of a semiconductor wafer
Ciszek, T.F.
1995-03-07
Apparatus for measuring thicknesses of semiconductor wafers is discussed, comprising: housing means for supporting a wafer in a light-tight environment; a light source mounted to the housing at one side of the wafer to emit light of a predetermined wavelength to normally impinge the wafer; a light detector supported at a predetermined distance from a side of the wafer opposite the side on which a light source impinges and adapted to receive light transmitted through the wafer; and means for measuring the transmitted light. 4 figs.
Scintillation probe with photomultiplier tube saturation indicator
Ruch, Jeffrey F.; Urban, David J.
1996-01-01
A photomultiplier tube saturation indicator is formed by supplying a supplemental light source, typically an light emitting diode (LED), adjacent to the photomultiplier tube. A switch allows the light source to be activated. The light is forwarded to the photomultiplier tube by an optical fiber. If the probe is properly light tight, then a meter attached to the indicator will register the light from the LED. If the probe is no longer light tight, and the saturation indicator is saturated, no signal will be registered when the LED is activated.
Output limitations to single stage and cascaded 2-2.5 mum light emitting diodes
NASA Astrophysics Data System (ADS)
Hudson, Andrew Ian
Since the advent of precise semiconductor engineering techniques in the 1960s, considerable effort has been devoted both in academia and private industry to the fabrication and testing of complex structures. In addition to other techniques, molecular beam epitaxy (MBE) has made it possible to create devices with single mono-layer accuracy. This facilitates the design of precise band structures and the selection of specific spectroscopic properties for light source materials. The applications of such engineered structures have made solid state devices common commercial quantities. These applications include solid state lasers, light emitting diodes and light sensors. Band gap engineering has been used to design emitters for many wavelength bands, including the short wavelength (SWIR) infrared region which ranges from 1.5 to 2.5mum. Practical devices include sensors operating in the 2-2.5mum range. When designing such a device, necessary concerns include the required bias voltage, operating current, input impedance and especially for emitters, the wall-plug efficiency. Three types of engineered structures are considered in this thesis. These include GaInAsSb quaternary alloy bulk active regions, GaInAsSb multiple quantum well devices (MQW) and GaInAsSb cascaded light emitting diodes. The three structures are evaluated according to specific standards applied to emitters of infrared light. The spectral profiles are obtained with photo or electro-luminescence, for the purpose of locating the peak emission wavelength. The peak wavelength for these specimens is in the 2.2-2.5mum window. The emission efficiency is determined by employing three empirical techniques: current/voltage (IV), radiance/current (LI), and carrier lifetime measurements. The first verifies that the structure has the correct electrical properties, by measuring among other parameters the activation voltage. The second is used to determine the energy efficiency of the device, including the wall-plug and quantum efficiencies. The last provides estimates of the relative magnitude of the Shockley Read Hall, radiative and Auger coefficients. These constants illustrate the overall radiative efficiency of the material, by noting comparisons between radiative and non-radiative recombination rates.
Blue enhanced light sources: opportunities and risks
NASA Astrophysics Data System (ADS)
Lang, Dieter
2012-03-01
Natural daylight is characterized by high proportions of blue light. By proof of a third type of photoreceptor in the human eye which is only sensitive in this spectral region and by subsequent studies it has become obvious that these blue proportions are essential for human health and well being. In various studies beneficial effects of indoor lighting with higher blue spectral proportions have been proven. On the other hand with increasing use of light sources having enhanced blue light for indoor illumination questions are arising about potential health risks attributed to blue light. Especially LED are showing distinct emission characteristics in the blue. Recently the French agency for food, environmental and occupational health & safety ANSES have raised the question on health issues related to LED light sources and have claimed to avoid use of LED for lighting in schools. In this paper parameters which are relevant for potential health risks will be shown and their contribution to risk factors will quantitatively be discussed. It will be shown how to differentiate between photometric parameters for assessment of beneficial as well as hazardous effects. Guidelines will be discussed how blue enhanced light sources can be used in applications to optimally support human health and well being and simultaneously avoid any risks attributed to blue light by a proper design of lighting parameters. In the conclusion it will be shown that no inherent health risks are related to LED lighting with a proper lighting design.
Deconnable self-reading pocket dosimeter containment with self-contained light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, R.L.; Arnold, G.N.; McBride, R.G.
1996-10-22
A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter. 4 figs.
Deconnable self-reading pocket dosimeter containment with self-contained light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, R.L.; Arnold, G.N.; McBride, R.G.
1995-12-31
A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.
Deconnable self-reading pocket dosimeter containment with self-contained light
Stevens, Robyn L.; Arnold, Greg N.; McBride, Ryan G.
1996-01-01
A container for a self-reading pocket dosimeter includes a transparent tube for receiving the self-reading pocket dosimeter, a light source mounted at one end of the transparent tube, and an eyepiece mounted on an opposite end of the transparent tube for viewing a read-out of the self-reading pocket dosimeter. The container may further include an activation device for selectively supplying power to the light source. The container both protects the dosimeter from being contaminated and provides a light source for viewing the dosimeter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tucker, R.A.
This paper reports that properly applied, light sources and lighting systems not only enhance a building's attractiveness and usability, they also create a secure environment. An effectively lighted area can minimize pedestrian hazards and auto accidents. Good security lighting also eliminates the darkness that vandals, thieves, and felons thrive on. Unfortunately, lighting quality has sometimes been sacrificed for the sake of energy efficiency, and resulting savings offset by poor aesthetics and user dissatisfaction. However, trade-offs in quality and efficiency are not necessary, thanks to recent developments in light source technology.
An entangled-light-emitting diode.
Salter, C L; Stevenson, R M; Farrer, I; Nicoll, C A; Ritchie, D A; Shields, A J
2010-06-03
An optical quantum computer, powerful enough to solve problems so far intractable using conventional digital logic, requires a large number of entangled photons. At present, entangled-light sources are optically driven with lasers, which are impractical for quantum computing owing to the bulk and complexity of the optics required for large-scale applications. Parametric down-conversion is the most widely used source of entangled light, and has been used to implement non-destructive quantum logic gates. However, these sources are Poissonian and probabilistically emit zero or multiple entangled photon pairs in most cycles, fundamentally limiting the success probability of quantum computational operations. These complications can be overcome by using an electrically driven on-demand source of entangled photon pairs, but so far such a source has not been produced. Here we report the realization of an electrically driven source of entangled photon pairs, consisting of a quantum dot embedded in a semiconductor light-emitting diode (LED) structure. We show that the device emits entangled photon pairs under d.c. and a.c. injection, the latter achieving an entanglement fidelity of up to 0.82. Entangled light with such high fidelity is sufficient for application in quantum relays, in core components of quantum computing such as teleportation, and in entanglement swapping. The a.c. operation of the entangled-light-emitting diode (ELED) indicates its potential function as an on-demand source without the need for a complicated laser driving system; consequently, the ELED is at present the best source on which to base future scalable quantum information applications.
40 CFR 86.1712-99 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2010 CFR
2010-07-01
... model year 1999 or 2000, the California engine family; (iv) Assembly plant; (v) Vehicle identification... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program for Light-Duty...
40 CFR 86.1712-99 - Maintenance of records; submittal of information.
Code of Federal Regulations, 2013 CFR
2013-07-01
... model year 1999 or 2000, the California engine family; (iv) Assembly plant; (v) Vehicle identification... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program for Light-Duty...
40 CFR 1027.105 - How much are the fees?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (ii) Light-duty vehicles and trucks California-only 16,944 (iii) Medium-duty passenger vehicles Federal 33,883 (iv) Medium-duty passenger vehicles California-only 16,944 (v) Highway motorcycle All 2,414...) Medium-duty passenger vehicles. (iii) Complete heavy-duty highway vehicles. (3) The following fees apply...
Relationships between Humor Styles and Family Functioning in Parents of Children with Disabilities
ERIC Educational Resources Information Center
Rieger, Alicja; McGrail, J. Patrick
2015-01-01
The humor styles and family functioning of parents of children with disabilities are understudied subjects. This study seeks to shed quantitative light on these areas. Seventy-two parents of children with disabilities completed the "Family Adaptability and Cohesion Evaluation Scales" (FACES IV) and the "Humor Styles…
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2014 CFR
2014-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
33 CFR 164.25 - Tests before entering or getting underway.
Code of Federal Regulations, 2012 CFR
2012-07-01
... emergency lighting and power systems in vessel control and propulsion machinery spaces. (5) Main propulsion...) The main steering gear from the alternative power supply, if installed. (iv) Each rudder angle... power failure alarm. (vi) Each remote steering gear power unit failure alarm. (vii) The full movement of...
Optimization approach to LED crop illumination inside a controlled ecological life support system
NASA Astrophysics Data System (ADS)
Avercheva, Olga; Berkovich, Yuliy A.; Bassarskaya, Elizaveta; Zhigalova, Tatiana; Smolyanina, Svetlana O.; Kochetova, Galina; Konovalova, Irina
Artificial lighting sources for growing plants can be efficiently used to control gas exchange and preserve the necessary closure of internal matter turnover in the atmosphere of a controlled ecological life support system (CELSS). However, the lighting sources contribute strongly to the equivalent mass of a CELSS. Thus, the choice of an optimal plant lighting regime largely determines the efficiency of the artificial ecosystem. Lighting systems based on light-emitting diodes (LEDs) are now considered the most promising for space applications (Massa et al., 2006). Many types of LEDs have been developed in recent years. Because of this, the problem of optimizing a lighting source for space vegetation chambers has become more difficult: we need to optimize more parameters (such as emission spectrum, light intensity, frequency of light pulses and the shape of the lighting field inside a vegetation chamber), and in a wider range of values. In this presentation we discuss approaches to optimizing the emission spectrum of a lighting source for the use in space applications, including CELSS. One of the benefits of LEDs is their narrow-band emission spectrum, which allows us to construct a lighting source with an optimal spectrum for plant growth and production. A number of experiments have shown that the reaction of plants to a narrow-band emission spectrum of LEDs is highly species-specific and affects many processes in plants. Adding a small amount of far red light to red and blue quanta increased biomass in radish and lettuce (Tamulaitis et al., 2005). Adding blue and near UV light of different wavelengths to red light decreased total sugar content in lettuce (Urbonavičiūtė et al., 2007) and Chinese cabbage (Avercheva et al., 2009). Supplemental green light improved the nutrition quality of some lettuce varieties: decreased nitrate content and increased ascorbic acid content (Samuoliene et al., 2012). It has also been shown that changes in lighting spectrum can lead to changes in hormone content in plant tissues, and to changes in the ratio of active and inactive forms of hormones (Golovatskaya, 2005; Tamulaitis et al., 2005; Minich et al., 2006). This, in turn, may lead to changes in plant growth and biomass composition. Thus, we should vary the emission spectrum of a lighting source to improve both the productivity (i.e. gas exchange) and nutrition quality of plants growing inside a CELSS. However, it is hard to find a universal spectrum for all plants and all applications. Fundamental studies of the finer effects of narrow-band light on plant growth and metabolism may be beneficial to explain these effects. On the basis of these studies, we may be able to formulate recommendations to optimize lighting sources for different plant species. One optimization approach to LED crop illumination inside CELSS could be use of white LEDs with proper addition of red LEDs. A more difficult approach is to construct lighting sources with a multiband spectrum to adjust it for specific applications experimentally.
DUV light source sustainability achievements and next steps
NASA Astrophysics Data System (ADS)
Roman, Yzzer; Cacouris, Ted; Raju, Kumar Raja Guvindan; Kanawade, Dinesh; Gillespie, Walt; Luo, Siqi; Mason, Eric; Manley, David; Das, Saptaparna
2018-03-01
Key sustainability opportunities have been executed in support of corporate initiatives to reduce the environmental footprint and decrease the running cost of DUV light sources. Previously, substantial neon savings were demonstrated over several years through optimized gas management technologies. Beyond this work, Cymer is developing the XLGR 100, a self-contained neon recycling system, to enable minimal gas consumption. The high efficiency results of the XLGR 100 in a production factory are validated in this paper. Cymer has also developed new light source modules with 33% longer life in an effort to reduce raw and associated resource consumption. In addition, a progress report is included regarding the improvements developed to reduce light source energy consumption.
Luongo, Giuseppe; Giubileo, Filippo; Genovese, Luca; Iemmo, Laura; Martucciello, Nadia; Di Bartolomeo, Antonio
2017-06-27
We study the effect of temperature and light on the I-V and C-V characteristics of a graphene/silicon Schottky diode. The device exhibits a reverse-bias photocurrent exceeding the forward current and achieves a photoresponsivity as high as 2.5 A / W . We show that the enhanced photocurrent is due to photo-generated carriers injected in the graphene/Si junction from the parasitic graphene/SiO₂/Si capacitor connected in parallel to the diode. The same mechanism can occur with thermally generated carriers, which contribute to the high leakage current often observed in graphene/Si junctions.
NASA Astrophysics Data System (ADS)
Mallidi, Srivalleesha; Mai, Zhiming; Rizvi, Imran; Hempstead, Joshua; Arnason, Stephen; Celli, Jonathan; Hasan, Tayyaba
2015-04-01
In view of the increase in cancer-related mortality rates in low- to middle-income countries (LMIC), there is an urgent need to develop economical therapies that can be utilized at minimal infrastructure institutions. Photodynamic therapy (PDT), a photochemistry-based treatment modality, offers such a possibility provided that low-cost light sources and photosensitizers are available. In this proof-of-principle study, we focus on adapting the PDT light source to a low-resource setting and compare an inexpensive, portable, battery-powered light-emitting diode (LED) light source with a standard, high-cost laser source. The comparison studies were performed in vivo in a xenograft murine model of human squamous cell carcinoma subjected to 5-aminolevulinic acid-induced protoporphyrin IX PDT. We observed virtually identical control of the tumor burden by both the LED source and the standard laser source. Further insights into the biological response were evaluated by biomarker analysis of necrosis, microvessel density, and hypoxia [carbonic anhydrase IX (CAIX) expression] among groups of control, LED-PDT, and laser-PDT treated mice. There is no significant difference in the percent necrotic volume and CAIX expression in tumors that were treated with the two different light sources. These encouraging preliminary results merit further investigations in orthotopic animal models of cancers prevalent in LMICs.
Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources
NASA Technical Reports Server (NTRS)
McAndrew, Brendan; Cooper, John; Arecchi, Angelo; McKee, Greg; Durell, Christopher
2012-01-01
Stable high radiance in visible and near-ultraviolet wavelengths is desirable for radiometric calibration sources. In this work, newly available electrodeless radio-frequency (RF) driven plasma light sources were combined with research grade, low-noise power supplies and coupled to an integrating sphere to produce a uniform radiance source. The stock light sources consist of a 28 VDC power supply, RF driver, and a resonant RF cavity. The RF cavity includes a small bulb with a fill gas that is ionized by the electric field and emits light. This assembly is known as the emitter. The RF driver supplies a source of RF energy to the emitter. In commercial form, embedded electronics within the RF driver perform a continual optimization routine to maximize energy transfer to the emitter. This optimization routine continually varies the light output sinusoidally by approximately 2% over a several-second period. Modifying to eliminate this optimization eliminates the sinusoidal variation but allows the output to slowly drift over time. This drift can be minimized by allowing sufficient warm-up time to achieve thermal equilibrium. It was also found that supplying the RF driver with a low-noise source of DC electrical power improves the stability of the lamp output. Finally, coupling the light into an integrating sphere reduces the effect of spatial fluctuations, and decreases noise at the output port of the sphere.
Shim, Jongmyeong; Park, Changsu; Lee, Jinhyung; Kang, Shinill
2016-08-08
Recently, studies have examined techniques for modeling the light distribution of light-emitting diodes (LEDs) for various applications owing to their low power consumption, longevity, and light weight. The energy mapping technique, a design method that matches the energy distributions of an LED light source and target area, has been the focus of active research because of its design efficiency and accuracy. However, these studies have not considered the effects of the emitting area of the LED source. Therefore, there are limitations to the design accuracy for small, high-power applications with a short distance between the light source and optical system. A design method for compensating for the light distribution of an extended source after the initial optics design based on a point source was proposed to overcome such limits, but its time-consuming process and limited design accuracy with multiple iterations raised the need for a new design method that considers an extended source in the initial design stage. This study proposed a method for designing discrete planar optics that controls the light distribution and minimizes the optical loss with an extended source and verified the proposed method experimentally. First, the extended source was modeled theoretically, and a design method for discrete planar optics with the optimum groove angle through energy mapping was proposed. To verify the design method, design for the discrete planar optics was achieved for applications in illumination for LED flash. In addition, discrete planar optics for LED illuminance were designed and fabricated to create a uniform illuminance distribution. Optical characterization of these structures showed that the design was optimal; i.e., we plotted the optical losses as a function of the groove angle, and found a clear minimum. Simulations and measurements showed that an efficient optical design was achieved for an extended source.