Shabib, Abdullah Bin; Alsayed, Fahad; Aldughaythir, Saad; Habeeb, Hanan; Al Tamimi, Sumayyah; Masuadi, Emad; Alzahrani, Mohsen; Alaklabi, Ali; Alotaibi, Azzam; Rajendram, Rajkumar; Almegren, Mosaad
2018-01-01
Inferior vena cava (IVC) filter is indicated in patients with acute venous thromboembolism (VTE) in whom therapeutic anticoagulation is contraindicated. While prophylactic insertion of an IVC filter may be considered for patients at high risk of VTE, there are significant differences between clinical guidelines on the role of IVC filters. These discrepancies have arisen predominantly because of the paucity of data on the efficacy and safety of IVC filters. We, therefore, evaluated the indications for filter insertion, the rate of filter retrieval and complications in patients who received IVC filters at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. A descriptive, retrospective review of electronic- and paper-based medical records was performed. Consecutive sampling was used to study all adult patients who received an IVC filter at KAMC between 2007 and 2016 and met the inclusion criteria. A total of 382 IVC filters were inserted. 113 patients (30%) had an acute VTE and a contraindication to anticoagulation while 53 patients (14%) received an IVC filter in the absence of VTE (i.e., prophylactic). Only 124 (32.5%) IVC filters were eventually retrieved. The most common reason for nonretrieval was the need for permanent filtration (155, 60%). Thrombotic complications developed in 72 (19%) patients; nine patients had fatal pulmonary embolism. The insertion of IVC filters in this cohort was associated with low retrieval rate and relatively high incidence of thrombotic complications. Follow-up of patients is required to detect IVC filter-related complications and to increase retrieval rate.
Klinken, Sven; Humphries, Charlotte; Ferguson, John
2017-10-01
To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = < 0.001). There was a non-significant reduction in IVC filter dwell time in the post-database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.
Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2017-12-01
Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.
Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo
2016-01-01
PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713
British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross; Chalmers, Nicholas
Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertionmore » and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.« less
Case of a Misplaced IVC Filter: A Lesson to Learn
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Sanjay, E-mail: drssharma@hotmail.com; Mukund, Amar, E-mail: dramarmukund@gmail.co; Agarwal, Sandeep, E-mail: sandeep_aiims@yahoo.co.i
2010-08-15
The inferior vena cava (IVC) filter insertion is a well established procedure to prevent significant pulmonary embolism in selected situations. It is generally considered straight forward without significant complications. We report an interesting case of a young postpartum woman in whom an IVC filter was misplaced in the right gonadal vein. This complication is only rarely reported. Presence of prominent right gonadal vein must always be kept in mind during trans-jugular placement of infra renal filter in the IVC in post partum women.
Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications
DeYoung, Elliot; Minocha, Jeet
2016-01-01
Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472
A Novel Technique for Inferior Vena Cava Filter Extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn
Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.
Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele
2018-03-01
The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanche, Alain F., E-mail: le_blanche.alain@chu-amiens.fr; Ricco, Jean-Baptiste; Bonneau, Michel
Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately aftermore » deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter's stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter's stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.« less
Duffett, L; Carrier, M
2017-01-01
Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.
A single center experience with retrievable IVC filters.
Renno, Anas; Khateeb, Faisal; Kazan, Viviane; Qu, Weikai; Gollapudi, Anurekha; Aplin, Brett; Abbas, Jihad; Zelenock, Gerald; Nazzal, Munier
2015-08-01
To evaluate retrievable IVC filters in our institution and assess their retrieval following a well-structured follow up program. Retrospective cohort study. The medical records of patients implanted with retrievable IVC filters were reviewed. All retrievable filter insertions between July 2007 and August 2011 at our institution were reviewed. Data was analyzed for age, gender, indication, complications, retrieval rate, and brand of filter inserted. Statistical analysis was done using SPSS software v19. Chi-square was used to compare discrete data and t-test for continuous data. P < 0.05 was significant. A total of 484 patients were reviewed of which 258 (53.1%) had a complete medical record. And 96 (37.2%) filters were placed as permanent at the time of insertion. An additional 40 (15.5%) filters were converted to permanent (total permanent filters 136; 52.7%). Death was reported in 26 (10%) patients and 96 (37.2%) out of the remaining 232 patients presented for potential retrieval. Also, 73 (28.2%) had an attempt to retrieve the filters, 69 (94.5%) were successful and 4 (5.4%) failed to retrieve. The remaining 23 (8.9%) patients declined retrieval. Filters studied include Celect (38%), Bard (31.4%), Option (26.2%), Tulip (4.1%), and Recovery (0.2%). Bard was more commonly used as a retrievable filter (80.9%). Retrieval on the first attempt was 90.4% (n = 66) successful. Of the remaining seven filters, three were successfully retrieved on a second attempt, and four failed to retrieve due to filter tilt. The success rates of retrieval for Celect and Tulip were significantly lower than for Bard (p = 0.04 and 0.023, respectively). Our study showed that a variety of IVC filters can be retrieved successfully with minimal complication rates. In more than half of our patients, IVC filters were used as permanent. Failure of retrieval was most frequently due to filter tilting. © The Author(s) 2014.
Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Basheer, Mamoun Ahmad, E-mail: drbasheer30@yahoo.co; Hamilton, Mark; Holdaway, Chris
2008-07-15
AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump tomore » more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.« less
Birkmeyer, Nancy J; Finks, Jonathan F; English, Wayne J; Carlin, Arthur M; Hawasli, Abdelkader A; Genaw, Jeffrey A; Wood, Michael H; Share, David A; Birkmeyer, John D
2013-04-01
The United States Food and Drug Administration recently issued a warning about adverse events in patients receiving inferior vena cava (IVC) filters. To assess relationships between IVC filter insertion and complications while controlling for differences in baseline patient characteristics and medical venous thromboembolism prophylaxis. Propensity-matched cohort study. The prospective, statewide, clinical registry of the Michigan Bariatric Surgery Collaborative. Bariatric surgery patients (n=35,477) from 32 hospitals during the years 2006 through 2012. Prophylactic IVC filter insertion. Outcomes included the occurrence of complications (pulmonary embolism, deep vein thrombosis, and overall combined rates of complications by severity) within 30 days of bariatric surgery. There were no significant differences in baseline characteristics among the 1,077 patients with IVC filters and in 1,077 matched control patients. Patients receiving IVC filters had higher rates of pulmonary embolism (0.84% vs 0.46%; odds ratio [OR], 2.0; 95% confidence interval [CI], 0.6-6.5; P=0.232), deep vein thrombosis (1.2% vs 0.37%; OR, 3.3; 95% CI, 1.1-10.1; P=0.039), venous thromboembolism (1.9% vs 0.74%; OR, 2.7; 95% CI, 1.1-6.3, P=0.027), serious complications (5.8% vs 3.8%; OR, 1.6; 95% CI, 1.0-2.4; P=0.031), permanently disabling complications (1.2% vs 0.37%; OR, 4.3; 95% CI, 1.2-15.6; P=0.028), and death (0.7% vs 0.09%; OR, 7.0; 95% CI, 0.9-57.3; P=0.068). Of the 7 deaths among patients with IVC filters, 4 were attributable to pulmonary embolism and 2 to IVC thrombosis/occlusion. We have identified no benefits and significant risks to the use of prophylactic IVC filters among bariatric surgery patients and believe that their use should be discouraged. Copyright © 2013 Society of Hospital Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, Richard A.; Teitelbaum, George P.; Stanley, Philip
Purpose: To report our experience with inferior vena cava (IVC) filters in pediatric patients. Methods: Over a 19-month period, eight low-profile percutaneously introducible IVC filters were placed in four male and four female patients aged 6-16 years (mean 11 years). Indications were contraindication to heparin in six patients, anticoagulation failure in one, and idiopathic infrarenal IVC thrombosis in one. Six of the eight devices placed were titanium Greenfield filters. One LGM and one Bird's Nest filter were also placed. Two of the filters were introduced via the right internal jugular vein by cutdown, and the remainder were placed percutaneously viamore » the right internal jugular vein or the right common femoral vein. Patients received follow-up abdominal radiographs from 2 to 13 months after IVC filter placement. Results: All filters were inserted successfully without complication. Three of the patients died during the follow-up period: two due to underlying brain tumors at 2 and 12 months and a third at 6 weeks due to progressive idiopathic renal vein and IVC thrombosis. The remaining five patients were all alive and well at follow-up without evidence of IVC thrombosis, pulmonary emboli, or filter migration. Conclusion: IVC filter placement using available devices for percutaneous delivery is technically feasible, safe, and effective in children.« less
Gotra, A; Doucet, C; Delli Fraine, P; Bessissow, A; Dey, C; Gallix, B; Boucher, L-M; Valenti, D
2018-05-14
To compare changes in inferior vena cava (IVC) filter positional parameters from insertion to removal and examine how they affect retrievability amongst various filter types. A total of 447 patients (260 men, 187 women) with a mean age of 55 years (range: 13-91 years) who underwent IVC filter retrieval between 2007-2014 were retrospectively included. Post-insertion and pre-retrieval angiographic studies were assessed for filter tilt, migration, strut wall penetration and retrieval outcomes. ANCOVA and multiple logistic regression models were used to analyze factors affecting retrieval success. Pairwise comparisons between filter types were performed. Of 488 IVC filter retrieval attempts, 94.1% were ultimately successful. The ALN filter had the highest mean absolute value of tilt (5.6 degrees), the Optease filter demonstrated the largest mean migration (-8.0mm) and the Bard G2 filter showed highest mean penetration (5.2mm). Dwell time of 0-90 days (OR, 11.1; P=0.01) or 90-180 days (OR, 2.6; P=0.02), net tilt of 10-15 degrees (OR 8.9; P=0.05), caudal migration of -10 to 0mm (OR, 3.46; P=0.03) and penetration less than 3mm (OR, 2.6; P=0.01) were positive predictors of successful retrievability. Higher odds of successful retrieval were obtained for the Bard G2X, Bard G2 and Cook Celect when compared to the ALN and Cordis Optease filters. Shorter dwell time, lower mean tilt, caudal migration and less caval wall penetration are positive predictors of successful IVC filter retrieval. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Coombs, Catherine; Kuk, Deborah; Devlin, Sean; Siegelbaum, Robert H; Durack, Jeremy C; Parameswaran, Rekha; Mantha, Simon; Deng, Kathy; Soff, Gerald
2017-11-01
Venous thromboembolism (VTE) is a common complication in cancer patients and anticoagulation (AC) remains the standard of care for treatment. Inferior vena cava (IVC) filters may also used to reduce the risk of pulmonary embolism, either alone or in addition to AC. Although widely used, data are limited on the safety and efficacy of IVC filters in cancer patients. We performed a retrospective review of outcomes after IVC filter insertion in a database of 1270 consecutive patients with cancer-associated pulmonary embolism (PE) at our institution between 2008 and 2009. Outcomes measured included rate of all recurrent VTE, recurrent PE, and overall survival within 12 months. 317 (25%) of the 1270 patients with PE had IVC filters placed within 30 days of the index PE event or prior to the index PE in the setting of prior DVT. Patients with IVC filters had markedly lower overall survival (7.3 months) than the non-IVC filter patients (13.2 months). Filter patients also had a lower rate of AC use at time of initial PE. There was a trend towards higher recurrent VTE in patients with IVC filters (11.9%) compared to non-filter patients (7.7%), but this was not significant (p = 0.086). The risk of recurrent PE was similar between the IVC filter cohort (3.5%) and non-filter group (3.5%, p = 0.99). Cancer patients receiving IVC filters had a similar risk of recurrent PE, but a trend towards more overall recurrent VTE. The filter patients had poorer overall survival, which may reflect a poorer cancer prognosis, and had greater contraindication to AC; therefore these patients likely had a higher inherent risk for recurrent VTE. A prospective study would be helpful for further clarification on the partial reduction in the recurrent PE risk by IVC filter placement in cancer patients.
Retrievable Inferior Vena Cava Filters for Venous Thromboembolism
Win, Lei Lei
2013-01-01
Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292
Novel and Advanced Techniques for Complex IVC Filter Retrieval.
Daye, Dania; Walker, T Gregory
2017-04-01
Inferior vena cava (IVC) filter placement is indicated for the treatment of venous thromboembolism (VTE) in patients with a contraindication to or a failure of anticoagulation. With the advent of retrievable IVC filters and their ease of placement, an increasing number of such filters are being inserted for prophylaxis in patients at high risk for VTE. Available data show that only a small number of these filters are retrieved within the recommended period, if at all, prompting the FDA to issue a statement on the need for their timely removal. With prolonged dwell times, advanced techniques may be needed for filter retrieval in up to 60% of the cases. In this article, we review standard and advanced IVC filter retrieval techniques including single-access, dual-access, and dissection techniques. Complicated filter retrievals carry a non-negligible risk for complications such as filter fragmentation and resultant embolization of filter components, venous pseudoaneurysms or stenoses, and breach of the integrity of the caval wall. Careful pre-retrieval assessment of IVC filter position, any significant degree of filter tilting or of hook, and/or strut epithelialization and caval wall penetration by filter components should be considered using dedicated cross-sectional imaging for procedural planning. In complex cases, the risk for retrieval complications should be carefully weighed against the risks of leaving the filter permanently indwelling. The decision to remove an embedded IVC filter using advanced techniques should be individualized to each patient and made with caution, based on the patient's age and existing comorbidities.
Temporary Inferior Vena Cava Filters: How Do We Move Forward?
Arous, Edward J; Messina, Louis M
2016-05-01
Despite their widespread use, the indications for the selective use of temporary inferior vena cava (IVC) filters remains uncertain with few trials supporting their use. Additionally, the risks of long-term temporary IVC filter insertion are being increasingly discussed amongst the mainstream media and through multiple class action lawsuits. Retrievable IVC filters were specifically designed to have a less secure implantation in order to facilitate retrieval. However, multiple reports have demonstrated significant filter-related complications, most commonly related to duration of implantation. Furthermore, the risk is not isolated to one manufacturer alone. The incidence of filter-related complications is linearly related to its duration of time on the market. Currently, the FDA recommends that IVC filters be removed within 25-54 days of their implantation. Unfortunately, little evidence exists to show that this recommendation is followed routinely. Recently, the PRESERVE Trial (NCT02381509) was initiated as a multicenter non-randomized open label study to determine the safety and effectiveness of commercially available IVC filters (both temporary and permanent) in individuals who require mechanical prophylaxis against pulmonary embolism. Until such evidence is developed, temporary IVC filters should be implanted based on best available evidence and routinely removed within the guidelines of the FDA of 25-54 days. A fair question at this point is whether the design features themselves that are required to manufacture a low profile removable IVC filter can achieve effective prophylaxis against pulmonary embolism at a low rate of short and long-term complications. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Inferior vena cava filters in trauma patients: efficacy, morbidity, and retrievability.
Smoot, Rory L; Koch, Cody A; Heller, Stephanie F; Sabater, Enrique A; Cullinane, Daniel C; Bannon, Michael P; Thomsen, Kristine M; Harmsen, William S; Baerga-Varela, Yvonne; Schiller, Henry J
2010-04-01
Thromboembolic events are potentially devastating sources of morbidity in trauma patients. With increasing experience and the introduction of retrievable devices, there has been a renewed interest in inferior vena cava (IVC) filters in trauma patients. The records for consecutive trauma patients undergoing IVC filter placement during the years 2001 to 2005 were reviewed, and clinical, demographic, and procedural data were evaluated for associations with thromboembolic events and device complications. During the study years, 226 trauma patients had IVC filters inserted, and 140 of these patients (62%) had retrievable IVC filters placed. Six patients (3%) had a pulmonary embolism with the filter in place, and two patients (1%) had a pulmonary embolism after filter removal. The most common complication was thrombosis in 27 patients (12%), with clinically significant thrombus occurring in 15 patients (7%). There was no association between the type of filter (permanent or retrievable) or the brand of retrievable filter and thrombosis. Specific risk factors for thrombosis could not be identified. Retrievable filters were successfully removed in 61% of patients with retrievable filters. Technical success rate was 97% in those patients who underwent attempted removal. Removal was completed at a median of 21 days (range, 2-292 days). Retrievable IVC filters in trauma patients are safe, but complications do occur with thrombosis being the most common. Retrieval has a high technical success rate when attempted. However, a significant number of trauma patients are lost to follow-up and this may impact the utilization of retrievable filters in this patient population.
Wadhwa, Vibhor; Trivedi, Premal S; Ali, Sumera; Ryu, Robert K; Pezeshkmehr, Amir
2018-02-01
Inferior vena cava (IVC) filter placement in children has been described in literature, but there is variability with regard to their indications. No nationally representative study has been done to compare practice patterns of filter placements at adult and children's hospitals. To perform a nationally representative comparison of IVC filter placement practices in children at adult and children's hospitals. The 2012 Kids' Inpatient Database was searched for IVC filter placements in children <18 years of age. Using the International Classification of Diseases, 9th Revision (ICD-9) code for filter insertion (38.7), IVC filter placements were identified. A small number of children with congenital cardiovascular anomalies codes were excluded to improve specificity of the code used to identify filter placement. Filter placements were further classified by patient demographics, hospital type (children's and adult), United States geographic region, urban/rural location, and teaching status. Statistical significance of differences between children's or adult hospitals was determined using the Wilcoxon rank sum test. A total of 618 IVC filter placements were identified in children <18 years (367 males, 251 females, age range: 5-18 years) during 2012. The majority of placements occurred in adult hospitals (573/618, 92.7%). Significantly more filters were placed in the setting of venous thromboembolism in children's hospitals (40/44, 90%) compared to adult hospitals (246/573, 43%) (P<0.001). Prophylactic filters comprised 327/573 (57%) at adult hospitals, with trauma being the most common indication (301/327, 92%). The mean length of stay for patients receiving filters was 24.5 days in children's hospitals and 18.4 days in adult hospitals. The majority of IVC filters in children are placed in adult hospital settings. Children's hospitals are more likely to place therapeutic filters for venous thromboembolism, compared to adult hospitals where the prophylactic setting of trauma predominates.
Chow, Felix Che-Lok; Chan, Yiu-Che; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung
2015-07-01
Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE), especially in patients with active contraindication to systemic anticoagulation. The aim of this study is to examine the outcomes of patients who received permanent IVC filters at our institution. This is a single-center retrospective observational study with review of a prospectively collected database for patients who had permanent IVC filters. Patient demographics, indications of filter placement, postprocedure clinical outcome and complications, as well as use of anticoagulant therapy were documented. Chi-squared test was used to test for statistically significant differences (IBM SPSS version 21; IBM Corp., Armonk, NY), while survival was calculated using Kaplan-Meier survival curves analysis. Between February 1998 and December 2013, a total of 109 patients with a median age of 65 (47 men, range 19-97) years had IVC filters inserted at our institution. All of them had documented venous thromboembolism (VTE) before filter placement: 99 (90.8%) had lower extremity deep vein thrombosis (DVT) (including 34 iliac, 65 infrainguinal), 9 (8.3%) had massive PE without evidence of lower limb DVT, and 1 (0.9%) had isolated IVC thrombosis. Forty-seven (43.1%) patients had PE before filter insertion. There were 2 serious procedure-related complications: one access site thrombosis and one right ventricular perforation. With a mean follow-up of 36 ± 33 months, no patient had further symptomatic PE or paradoxical embolism. There were a total of 54 (49.5%) deaths, with a 30-day mortality of 8.3%; none of them was device or procedure related. Among the 92 patients followed up, 27 (29.3%) had further VTE-either DVT in the index or the contralateral lower limb (20 patients, 21.7%), or thrombus inside the filter or the IVC (14 patients, 15.2%). Forty-one (44.6%) patients reported post-thrombotic syndrome (PTS) symptoms. Anticoagulant therapy was given to 39 (42.4%) and 55 (59.8%) patients in the periprocedural period and at any time during the study period, respectively. It did not reduce the rate of postfilter VTE or PTS in both instances. None of the filters in this series was retrieved. This observational study showed that IVC filters were effective in the prevention of PE, although symptomatic postfilter VTE and PTS were common, leading to significant morbidity. Patients who received permanent filters have high mortality on follow-up; however, none were procedure or device related. Copyright © 2015 Elsevier Inc. All rights reserved.
Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A
2017-06-01
This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping
2014-01-01
Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.
2004-01-15
We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.
Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro
2008-10-01
A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.
The Mid-Term Efficacy and Safety of a Permanent Nitinol IVC Filter (TrapEase)
Liu, Wei Chiang; Choo, Sung Wook; Kim, Dong-Ik; Kim, Young Wook; Kim, Duk-Kyung; Shin, Sung Wook; Park, Kwang Bo; Jeon, Yong Hwan; Choo, In-Wook
2005-01-01
Objective 1) To evaluate the mid-term efficacy and safety of a permanent nitinol inferior vena cava (IVC) filter; 2) to evaluate filter effectiveness, filter stability and caval occlusion. Materials and Methods A prospective evaluation of the TrapEase IVC filter was performed on 42 patients (eight men, 34 women) ranging in age from 22 to 78 years (mean age 66 years). All patients were ill with a high risk of pulmonary embolism (PE). Indications for filter placement were: 1) deep vein thrombosis with recurrent thromboembolism; 2) and/or free-floating thrombus with contraindication to anticoagulation; and 3) complications in achieving adequate anticoagulation. Follow-up evaluations (mean: 15.4 months, range: 2 to 28 months) were performed at 6- and 12-month intervals after the procedure and included clinical histories, chart reviews, plain film, Doppler ultrasounds, and contrasted abdominal CT scans. Results In follow-up evaluations, the data analysis revealed no cases of symptomatic PE. There were no cases of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study, there was one case of filter thrombosis; early symptomatic thrombosis that was successfully treated in the hospital. Of the 42 subjects, eight died. These deaths were not related to the filter device or the implantation procedure, but to the underlying disease. Conclusion This study demonstrates that the TrapEase permanent IVC filter is a safe and an effective device with low complication rates and is best used in patients with thromboembolic disease with a high risk of PE. PMID:15968150
DOE Office of Scientific and Technical Information (OSTI.GOV)
Looby, S.; Given, M.F.; Geoghegan, T.
Purpose. We evaluated the Gunther Tulip (GT) retrievable inferior vena cava (IVC) filter with regard to indications, filtration efficacy, complications, retrieval window, and use of anticoagulation. Method. A retrospective study was performed of 147 patients (64 men, 83 women; mean age 58.8 years) who underwent retrievable GT filter insertion between 2001 and 2005. The indications for placement included a diagnosis of pulmonary embolism or deep venous thrombosis with a contraindication to anticoagulation (n = 68), pulmonary embolism or deep venous thrombosis while on anticoagulation (n = 49), prophylactic filter placement for high-risk surgical patients with a past history of pulmonarymore » embolism or deep venous thrombosis (n = 20), and a high risk of pulmonary embolism or deep venous thrombosis (n = 10). Forty-nine of the 147 patients did not receive anticoagulation (33.7%) while 96 of 147 patients did, 82 of these receiving warfarin (56.5%), 11 receiving low-molecular weight heparins (7.58%), and 3 receiving antiplatelet agents alone (2.06%). Results. Filter placement was successful in 147 patients (100%). Two patients had two filters inserted. Of the 147 patients, filter deployment was on a permanent basis in 102 and with an intention to retrieve in 45 patients. There were 36 (80%) successful retrievals and 9 (20%) failed retrievals. The mean time to retrieval was 33.6 days. The reasons for failed retrieval included filter struts tightly adherent to the IVC wall (5/9), extreme filter tilt (2/9), and extensive filter thrombus (2/9). Complications included pneumothorax (n = 4), failure of filter expansion (n = 1), and breakthrough pulmonary embolism (n = 1). No IVC thrombotic episodes were recorded. Discussion. The Gunther Tulip retrievable filter can be used as a permanent or a retrievable filter. It is safe and efficacious. GT filters can be safely retrieved at a mean time interval of 33.6 days. The newly developed Celect filter may extend the retrieval interval.« less
Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli
2016-02-01
Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.
NASA Astrophysics Data System (ADS)
Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent
2013-11-01
A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.
Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?
Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette
2018-03-01
Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study shows that the filter appears to protect against PE in pregnancy but the numbers are small. Complications such as filter thrombosis and IVC penetration appear to be higher in pregnancy but this difference is not statistically significant. It is not possible to retrieve the device in one out of every four pregnant women. This has implications in terms of long term risk of lower limb thrombosis and post thrombotic syndrome. The decision to use an IVC filter in pregnancy needs careful consideration by a multidisciplinary team. The benefit and risk assessment should be individualised and clearly outlined to the patient. Copyright © 2017 Elsevier B.V. All rights reserved.
Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A
2010-05-01
Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively implemented algorithm, thereby limiting the need for transport in this high-risk population. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach
Inagaki, Elica; Farber, Alik; Eslami, Mohammad H.; Siracuse, Jeffrey J.; Rybin, Denis V.; Sarosiek, Shayna; Sloan, J. Mark; Kalish, Jeffrey
2017-01-01
Objective The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. Methods All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. Results In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). Conclusions The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. PMID:27318045
Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir
2016-05-01
To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng
2018-04-11
A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.
Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach.
Inagaki, Elica; Farber, Alik; Eslami, Mohammad H; Siracuse, Jeffrey J; Rybin, Denis V; Sarosiek, Shayna; Sloan, J Mark; Kalish, Jeffrey
2016-07-01
The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Yamashita, Yugo; Unoki, Takashi; Takagi, Daisuke; Hamatani, Yasuhiro; Ishii, Mitsuru; Iguchi, Moritake; Ogawa, Hisashi; Masunaga, Nobutoyo; Wada, Hiromichi; Hasegawa, Koji; Abe, Mitsuru; Akao, Masaharu
2016-07-01
A recent multicenter registry study of venous thromboembolism (VTE) patients in Japan demonstrated a high prevalence of inferior vena cava (IVC) filter placement. However, data regarding indications, applications, and outcomes of IVC filters in Japanese patients are quite limited. This study was an observational, single-center, retrospective cohort study of all consecutive patients with acute VTE treated between March 2006 and February 2014. Data extracted included patient demographics, indications, applications, and complications of IVC filters, as well as VTE recurrence and death. A total of 257 consecutive patients were analyzed. Seventy-eight patients (30 %) received IVC filters. The proportions of IVC filter placement were 26 % for deep-vein thrombosis (DVT) alone, 10 % for pulmonary embolism (PE) alone, and 46 % for both DVT and PE. There was no significant difference in patient demographics between the IVC filter group and no-IVC filter group. Stated indications for filter placement were 24 cases (30 %) of DVT in intrapelvic veins, 16 cases (20 %) of DVT in proximal veins, and 11 cases (14 %) of contraindication to anticoagulant therapy. In the IVC filter group, cases of class I indication (guidelines: JCS 75:1258-1281, 2009) numbered only 6 (8 %). Many of the retrievable IVC filters were not removed and placed permanently and the retrieval rate was 42 %. We found complications of IVC filters in 8 cases (10 %). IVC filter placement was significantly associated with a better survival rate and a higher incidence of DVT recurrence during a mean observation period of 541 days. Our research suggests the frequent use of IVC filters for VTE treatment, combined with a low retrieval rate. Most of the stated indications of IVC filter placement for VTE in Japanese patients were cases of DVT in intrapelvic veins or proximal veins, not cases of contraindication to anticoagulant therapy.
Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.
Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C
2018-04-01
To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Charalel, Resmi A; Durack, Jeremy C; Mao, Jialin; Ross, Joseph S; Meltzer, Andrew J; Sedrakyan, Art
2018-03-01
Public awareness of inferior vena cava (IVC) filter-related controversies has been elevated by the Food and Drug Administration (FDA) safety communication in 2010. To examine population level trends in IVC filter utilization, complications, retrieval rates, and subsequent pulmonary embolism (PE) risk. A retrospective cohort study. Patients receiving IVC filters during 2005-2014 in New York State. IVC filter-specific complications, new PE occurrences and IVC filter retrievals were evaluated as time-to-event data using Kaplan-Meier analysis. Estimated cumulative risks were obtained at various timepoints during follow-up. There were 91,873 patients receiving IVC filters between 2005 and 2014 in New York State included in the study. The average patient age was 67 years and 46.6% were male. Age-adjusted rates of IVC filter placement increased from 48 cases/100,000 in 2005 to 52 cases/100,000 in 2009, and decreased afterwards to 36 cases/100,000 in 2014. The estimated risks of having an IVC filter-related complication and filter retrieval within 1 year was 1.5% [95% confidence interval (CI), 1.4%-1.6%] and 3.5% (95% CI, 3.4%-3.6%). One-year retrieval rate was higher post-2010 when compared with pre-2010 years (hazard ratio, 2.70; 95% CI, 2.50-2.91). Among the 58,176 patients who did not have PE events before or at the time of IVC filter placement, the estimated risk of developing subsequent PE at 1 year was 2.0% (95% CI, 1.9%-2.1%). Our findings suggest that FDA communications may be effective in modifying statewide clinical practices. Given the 2% observed PE rate following prophylactic IVC filter placement, large scale pragmatic studies are needed to determine contemporary safety and effectiveness of IVC filters.
McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory
2013-11-01
To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.
Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.
Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F
2018-05-03
To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.
Durack, Jeremy C; Westphalen, Antonio C; Kekulawela, Stephanie; Bhanu, Shiv B; Avrin, David E; Gordon, Roy L; Kerlan, Robert K
2012-04-01
This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Günther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Günther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Günther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Longer indwelling times usually result in vena caval perforation by retrievable Günther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durack, Jeremy C., E-mail: jeremy.durack@ucsf.edu; Westphalen, Antonio C.; Kekulawela, Stephanie
Purpose: This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Guenther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Methods: Guenther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Guenther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissuemore » injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Results: Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Conclusions: Longer indwelling times usually result in vena caval perforation by retrievable Guenther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.« less
Makary, Mina S; Kapke, Jordan; Yildiz, Vedat; Pan, Xueliang; Dowell, Joshua D
2018-02-01
To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P < .01). Fluoroscopy time was similar for IR and OR filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.
Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John
2015-06-01
Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.
Deso, Steven E.; Idakoji, Ibrahim A.; Muelly, Michael C.; Kuo, William T.
2016-01-01
Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board–approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters. PMID:27247483
Deso, Steven E; Idakoji, Ibrahim A; Muelly, Michael C; Kuo, William T
2016-06-01
Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.
Aycock, Kenneth I; Campbell, Robert L; Manning, Keefe B; Craven, Brent A
2017-06-01
Inferior vena cava (IVC) filters are medical devices designed to provide a mechanical barrier to the passage of emboli from the deep veins of the legs to the heart and lungs. Despite decades of development and clinical use, IVC filters still fail to prevent the passage of all hazardous emboli. The objective of this study is to (1) develop a resolved two-way computational model of embolus transport, (2) provide verification and validation evidence for the model, and (3) demonstrate the ability of the model to predict the embolus-trapping efficiency of an IVC filter. Our model couples computational fluid dynamics simulations of blood flow to six-degree-of-freedom simulations of embolus transport and resolves the interactions between rigid, spherical emboli and the blood flow using an immersed boundary method. Following model development and numerical verification and validation of the computational approach against benchmark data from the literature, embolus transport simulations are performed in an idealized IVC geometry. Centered and tilted filter orientations are considered using a nonlinear finite element-based virtual filter placement procedure. A total of 2048 coupled CFD/6-DOF simulations are performed to predict the embolus-trapping statistics of the filter. The simulations predict that the embolus-trapping efficiency of the IVC filter increases with increasing embolus diameter and increasing embolus-to-blood density ratio. Tilted filter placement is found to decrease the embolus-trapping efficiency compared with centered filter placement. Multiple embolus-trapping locations are predicted for the IVC filter, and the trapping locations are predicted to shift upstream and toward the vessel wall with increasing embolus diameter. Simulations of the injection of successive emboli into the IVC are also performed and reveal that the embolus-trapping efficiency decreases with increasing thrombus load in the IVC filter. In future work, the computational tool could be used to investigate IVC filter design improvements, the effect of patient anatomy on embolus transport and IVC filter embolus-trapping efficiency, and, with further development and validation, optimal filter selection and placement on a patient-specific basis.
Percutaneous Retrieval of Permanent Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu; Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Holly, Brian, E-mail: bholly3@jhmi.edu
PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filtersmore » was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.« less
Pan, Y; Zhao, J; Mei, J; Shao, M; Zhang, J; Wu, H
2016-12-01
The incidence of thrombus was investigated within retrievable filters placed in trauma patients with confirmed DVT at the time of retrieval and the optimal treatment for this clinical scenario was assessed. A technique called "filter retrieval with manual negative pressure aspiration thrombectomy" for management of filter thrombus was introduced and assessed. The retrievable filters referred for retrieval between January 2008 and December 2015 were retrospectively reviewed to determine the incidence of filter thrombus on a pre-retrieval cavogram. The clinical outcomes of different managements for thrombus within filters were recorded and analyzed. During the study 764 patients having Aegisy Filters implanted were referred for filter removal, from which 236 cases (134 male patients, mean age 50.2 years) of thrombus within the filter were observed on initial pre-retrieval IVC venogram 12-39 days after insertion (average 16.9 days). The incidence of infra-filter thrombus was 30.9%, and complete occlusion of the filter bearing IVC was seen in 2.4% (18) of cases. Retrieval was attempted in all 121 cases with small clots using a regular snare and sheath technique, and was successful in 120. A total of 116 cases with massive thrombus and IVC occlusion by thrombus were treated by CDT and/or the new retrieval technique. Overall, 213 cases (90.3%) of thrombus in the filter were removed successfully without PE. A small thrombus within the filter can be safely removed without additional management. CDT for reduction of the clot burden in filters was effective and safe. Filter retrieval with manual negative pressure aspiration thrombectomy seemed reasonable and valuable for management of massive thrombus within filters in some patients. Full assessment of the value and safety of this technique requires additional studies. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran
2015-01-01
Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846
Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type
Deso, Steven E.; Idakoji, Ibrahim A.; Kuo, William T.
2016-01-01
Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90–100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30–50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters. PMID:27247477
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiefer, Ryan M., E-mail: rkiefer11@gmail.com; Pandey, Nirnimesh; Trerotola, Scott O.
PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tipmore » embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.« less
Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K
2015-04-01
To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Huang, Steven Y; Eggers, Mitchell; McArthur, Mark J; Dixon, Katherine A; McWatters, Amanda; Dria, Stephen; Hill, Lori R; Melancon, Marites P; Steele, Joseph R; Wallace, Michael J
2017-12-01
Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3). Autologous thrombus was administered from below the filter in seven swine from 0 to 35 days after filter placement. Fluoroscopy and computed tomography follow-up was performed after filter deployment from weeks 1-6 (weekly), weeks 7-20 (biweekly), and weeks 21-32 (monthly). The infrarenal IVC, lungs, heart, liver, kidneys, and spleen were harvested at necropsy. Continuous variables were evaluated with a Student t test. Results There was no evidence of IVC thrombosis, device migration, caval penetration, or pulmonary embolism. Gross pathologic analysis showed gradual device resorption until 32 weeks after deployment. Histologic assessment demonstrated neointimal hyperplasia around the IVC filter within 2 weeks after IVC filter deployment with residual microscopic fragments of polydioxanone suture within the caval wall at 32 weeks. Each iatrogenic-administered thrombus was successfully captured by the filter until resorbed (range, 1-4 weeks). Conclusion An absorbable IVC filter can be safely deployed in swine and resorbs gradually over the 32-week testing period. The device is effective for the prevention of pulmonary embolism for at least 5 weeks after placement in swine. © RSNA, 2017.
Complications of inferior vena cava filters
Grewal, Simer; Chamarthy, Murthy R.
2016-01-01
Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983
Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R
2017-01-01
Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.
Jiang, Jianguang; Tu, Jianfei; Jia, Zhongzhi; Chen, Jiezhong; Cao, Haitao; Meng, Qingli; Fuller, Tyler A; Tian, Feng
2017-01-01
The aim of the study was to retrospectively evaluate the incidence and outcomes of inferior vena cava (IVC) filter thrombus during catheter-directed thrombolysis (CDT) for acute proximal deep venous thrombosis (DVT). From October 2006 to June 2015, patients diagnosed with acute proximal DVT and received CDT after a retrievable IVC filter was placed were included. The incidence, treatment, and outcomes of IVC filter thrombus during CDT were recorded and analyzed. A total of 189 patients (91 women, 98 men; mean age, 57.6 ± 9.8 years; range, 24-85 years) were included in this study. Among the 189 cases, the DVTs involved popliteal iliofemoral veins in 54 patients, iliofemoral veins in 113 patients, and iliac veins in 22 patients, of which 18 patients had thrombus extended into the IVC. Of the 189 patients, a total of 8 (4.2%, 8 of 189) patients were identified with IVC filter thrombus during CDT. The IVC filter thrombus was detected on a median of 2 days (range, 2-4 days) of CDT therapy, including small-size (n = 6) and large-size (n = 2) filter thrombus. Of the 8 patients, CDTs were performed with a mean 7.6 ± 1.1 days (range, 6-11 days) after the presence of symptoms for the treatment of proximal DVT, and all the IVC filter thrombi were lysed during CDT for the proximal DVT. All the IVC filters were removed successfully with a mean of 12.8 ± 0.93 days from placement. There were no procedure- or thrombolysis-related major complications, and no symptomatic pulmonary embolism breakthrough was seen in any of the patients after the filter placement. IVC filter thrombus during CDT for the acute proximal DVT is uncommon, and all of them did not need any additional treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laborda, Alicia, E-mail: alaborda@unizar.es; Kuo, William T., E-mail: wkuo@stanford.edu; Ioakeim, Ignatios, E-mail: ignacio.ioakim@hotmail.es
2015-10-15
PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava weremore » measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.« less
It all unraveled from there: case report of a central venous catheter guidewire unraveling.
Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc
2014-12-01
Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.
The high-risk polytrauma patient and inferior vena cava filter use.
Berber, Onur; Vasireddy, Aswin; Nzeako, Obi; Tavakkolizadeh, Adel
2017-07-01
The aim of this study was to assess the impact on practice of vena cava filter insertion guidelines (Eastern Association for the Surgery of Trauma: practice management guidelines). The study was performed at a level 1 trauma centre with data from the 'Trauma Audit and Research Network' cross-referenced to hospital data. A total of 1138 specific 'high-risk' major trauma patients were identified over a 6-year period. The mean age was 46 years (18-102) and the male to female ratio was 3.3:1. The average Injury Severity Score was 23.6 (4-75). The overall DVT rate was 2.6% and the PE rate was 1.8%. A retrievable IVC filter was inserted in 42 cases (3.8%). The filter retrieval rate was 23.8% at a mean of 68.5days (4-107). Only one complication was reported of a breakthrough PE despite filter. Applying the EAST guidelines to this cohort would have suggested filter insertion in 279 (24.6%) cases. The kappa concordance value between observed practice and the 'EAST filter group' was 0.103 (poor). The PE rate in the 'EAST filter group' was 2.2% vs 1.6% in the 'no filter group' (p=0.601, no statistical difference) and the observed odds ratio was 0.814 (95% CI 0.413, 1.602). The EAST guidelines are useful but may be overestimating the need for filter insertion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Doshi, Mehul Harshad; Narayanan, Govindarajan
2016-12-01
Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.
Inferior vena cava filter retrievals, standard and novel techniques.
Kuyumcu, Gokhan; Walker, T Gregory
2016-12-01
The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques.
Inferior vena cava filter retrievals, standard and novel techniques
Walker, T. Gregory
2016-01-01
The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques. PMID:28123984
CT of inferior vena cava filters: normal presentations and potential complications.
Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man
2015-12-01
With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.
Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok
2016-05-01
To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.
Falatko, John M; Dalal, Bhavinkumar; Qu, Lihua
2017-12-01
Anticoagulation is the primary treatment for pulmonary embolism (PE). Inferior vena cava (IVC) filters are an adjunctive intervention to prevent recurrent pulmonary embolism. Long-term outcomes in elderly patients with contraindications to anticoagulation after IVC filter placement for prevention of recurrent pulmonary embolism have yet to be assessed. Patients ≥60years of age, that had an IVC filter placed between 1 January, 2008 and 2 February, 2013, with a primary diagnosis of pulmonary embolism, were included. Patients that died during index hospitalisation, were discharged to hospice, or had active malignancy were excluded. The primary endpoint was overall survival. Patients were divided depending on whether they were treated with an approved anticoagulant for VTE or had no anticoagulant. Of the 152 patients identified, 55 were not anti-coagulated after IVC filter placement. The incidence of death was 0.4 per 1000 filter days and 0.7 per 1000 filter days in the anti-coagulated and untreated groups respectively (p-value=0.06). After statistical correction for co-morbid conditions, the effect of anticoagulation was not significant (HR 0.82 CI 0.49-1.37, p-value 0.46). Age was a significant confounder that was associated with death. Increased BMI was protective. Indications for IVC filter placement were numerous, but similar between the two groups. Treatment with an approved anticoagulant is recommended after IVC filter placement for prevention of recurrent PE, however its effect may be attenuated by advanced age. In elderly patients that have undergone IVC filter placement for prevention of recurrent PE, survival may be more dependent on age and co-morbid conditions than exposure to anticoagulation. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane
2012-11-01
To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.
Everhart, Damian; Vaccaro, Jamieson; Worley, Karen; Rogstad, Teresa L; Seleznick, Mitchel
2017-08-01
The role of inferior vena cava filter (IVC) filters for prevention of pulmonary embolism (PE) is controversial. This study evaluated outcomes of IVC filter placement in a managed care population. This retrospective cohort study evaluated data for individuals with Humana healthcare coverage 2013-2014. The study population included 435 recipients of prophylactic IVC filters, 4376 recipients of therapeutic filters, and two control groups, each matched to filter recipients. Patients were followed for up to 2 years. Post-index anticoagulant use, mortality, filter removal, device-related complications, and all-cause utilization. Adjusted regression analyses showed a positive association between filter placement and anticoagulant use at 3 months: odds ratio (ORs) 3.403 (95% CI 1.912-6.059), prophylactic; OR, 1.356 (95% CI 1.164-1.58), therapeutic. Filters were removed in 15.67% of prophylactic and 5.69% of therapeutic filter cases. Complication rates were higher with prophylactic procedures than with therapeutic procedures and typically exceeded 2% in the prophylactic group. Each form of filter placement was associated with increases in all-cause hospitalization (regression coefficient 0.295 [95% CI 0.093-0.498], prophylactic; 0.673 [95% CI 0.547-0.798], therapeutic) and readmissions (OR 2.444 [95% CI 1.298-4.602], prophylactic; 2.074 [95% CI 1.644-2.616], therapeutic). IVC filter placement in this managed care population was associated with increased use of anticoagulants and greater healthcare utilization compared to controls, low rates of retrieval, and notable rates of device-related complications, with effects especially pronounced in assessments of prophylactic filters. These findings underscore the need for appropriate use of IVC filters.
Radiology-led Follow-up System for IVC Filters: Effects on Retrieval Rates and Times
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, L.; Taylor, J.; Munneke, G.
Purpose: Successful IVC filter retrieval rates fall with time. Serious complications have been reported following attempts to remove filters after 3-18 months. Failed retrieval may be associated with adverse clinical sequelae. This study explored whether retrieval rates are improved if interventional radiologists organize patient follow-up, rather than relying on the referring clinicians. Methods: Proactive follow-up of patients who undergo filter placement was implemented in May 2008. At the time of filter placement, a report was issued to the referring consultant notifying them of the advised timeframe for filter retrieval. Clinicians were contacted to arrange retrieval within 30 days. We comparedmore » this with our practice for the preceding year. Results: The numbers of filters inserted during the two time periods was similar, as were the numbers of retrieval attempts and the time scale at which they occurred. The rate of successful retrievals increased but not significantly. The major changes were better documentation of filter types and better clinical follow-up. After the change in practice, only one patient was lost to follow-up compared with six the preceding year. Conclusions: Although there was no significant improvement in retrieval rates, the proactive, radiology-led approach improved follow-up and documentation, ensuring that a clinical decision was made about how long the filter was required and whether retrieval should be attempted and ensuring that patients were not lost to follow-up.« less
Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R
2015-10-01
Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.
Pilot in vivo study of an absorbable polydioxanone vena cava filter.
Eggers, Mitchell D; McArthur, Mark J; Figueira, Tomas A; Abdelsalam, Mohamed E; Dixon, Katherine P; Pageon, Laura R; Wallace, Michael J; Huang, Steven Y
2015-10-01
The objectives of this study were to evaluate tensile strength retention of polydioxanone as a function of time in a swine venous system and to assess the feasibility of an absorbable inferior vena cava (IVC) filter made from polydioxanone in a pilot swine study. Twenty strands (60 cm each) of size 1 polydioxanone absorbable suture (Ethicon, Somerville, NJ) were placed in the central venous system of domestic swine. Strands were harvested at weekly intervals during 10 weeks for tensile strength testing. Results were compared with control samples obtained from an in vitro engineered circulation system containing sodium phosphate buffer solution. Three IVC filters braided from polydioxanone suture were also catheter deployed in three swine to assess absorbable IVC filter feasibility. Polydioxanone retained 82% tensile strength in vitro vs 79% in vivo at 35 days (P > .22), the desired prophylactic duration. For IVC filters made from polydioxanone, technical success of placement was achieved in all three filters deployed (100%). Autologous thrombus deployed inferior to the filter remained trapped in the filter until thrombus resorption, with no evidence of pulmonary emboli on follow-up computed tomography. There were no instances of caval penetration, filter-induced IVC thrombosis, filter migration, or tilt >15 degrees with imaging and clinical follow-up carried out to 32 weeks. Strength retention of polydioxanone suture placed in the venous system of swine is similar to earlier in vitro studies out to 10 weeks (P > .06 for all weeks) and is more than sufficient (8.20 ± 0.37 kg mean load at break for size 1) to trap thrombus. Pilot animal study suggests that an absorbable polydioxanone IVC filter can be catheter deployed to capture and to hold iatrogenically administered autologous thrombus through resorption. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
IVC filter retrieval in adolescents: experience in a tertiary pediatric center.
Guzman, Anthony K; Zahra, Mahmoud; Trerotola, Scott O; Raffini, Leslie J; Itkin, Maxim; Keller, Marc S; Cahill, Anne Marie
2016-04-01
Inferior vena cava (IVC) filters are commonly implanted with the intent to prevent life-threatening pulmonary embolism in at-risk patients with contraindications to anticoagulation. Various studies have reported increases in the rate of venous thromboembolism within the pediatric population. The utility and safety of IVC filters in children has not yet been fully defined. To describe the technique and adjunctive maneuvers of IVC filter removal in children, demonstrate its technical success and identify complications. A retrospective 10-year review was performed of 20 children (13 male, 7 female), mean age: 15.1 years (range: 12-19 years), who underwent IVC filter retrieval. Eleven of 20 (55%) were placed in our institution. Electronic medical records were reviewed for filter characteristics, retrieval technique, technical success and complications. The technical success rate was 100%. Placement indications included: deep venous thrombosis with a contraindication to anticoagulation (10/20, 50%), free-floating thrombus (4/20, 20%), post-trauma pulmonary embolism prophylaxis (3/20, 15%) and pre-thrombolysis pulmonary patient (1/20, 5%). The mean implantation period was 63 days (range: 20-270 days). Standard retrieval was performed in 17/20 patients (85%). Adjunctive techniques were performed in 3/20 patients (15%) and included the double-snare technique, balloon assistance and endobronchial forceps retrieval. Median procedure time was 60 min (range: 45-240 min). Pre-retrieval cavogram demonstrated filter tilt in 5/20 patients (25%) with a mean angle of 17° (range: 8-40). Pre-retrieval CT demonstrated strut wall penetration and tip embedment in one patient each. There were two procedure-related complications: IVC mural dissection noted on venography in one patient and snare catheter fracture requiring retrieval in one patient. There were no early or late complications. In children, IVC filter retrieval can be performed safely but may be challenging, especially in cases of filter tilt or embedding. Adjunctive techniques may increase filter retrieval rates.
Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmad, Iftikhar; Yeddula, Kalpana; Wicky, Stephan
The purpose of this study was to assess the long-term clinical sequelae of inferior vena cava (IVC) filter thrombus and the effect of anticoagulation on filter thrombus. Of 1,718 patients who had IVC filters placed during 2001-2008, 598 (34.8%) had follow-up abdominal CT. Filter thrombus was seen in 111 of the 598 (18.6%). There were 44 men (39.6%). The mean age at filter placement was 64 years. The medical diseases included cancer in 64, trauma in 15, stroke in 12, and others in 20. The frequency of filter thrombus on CT and asymptomatic filter thrombus on CT was calculated. Themore » frequency of pulmonary embolism (PE) in patients with filter thrombus was calculated. The frequency of thrombus progression or regression (on CT, available in 56) was calculated. The effect of anticoagulation on filter thrombus regression/progression was evaluated using the Fisher exact test by comparing the group of patients who received anticoagulants versus those who did not. A P-value of <0.05 was considered significant. The overall frequency of filter thrombus was 18.6%. Total occlusion of the IVC filter was seen in 12 of 598 (2%). The filter thrombus was asymptomatic in 110 (18.3%). Filter thrombus was detected after a median of 35 days (range, 0-2082) following filter placement. Thrombus extended above the filter in 4 (3.6%); IVC thrombus below the filter was seen in 35(31.5%). Thrombus in the filter occluded <25% of the filter volume in 58 (52.3%), 25-50% in 21 (18.9%), and 50-75% in 20 (18%). Total IVC occlusion was seen in 12 (10.8%). Eighty-three patients received anticoagulation. Sixteen patients developed symptoms of PE. PE was confirmed on CT in 3 of 15 (2.7%). On follow-up, filter thrombus regressed completely in 19 (33.9%) after a median of 6 months. Filter thrombus decreased in size in 13 (23.2%) and it progressed without IVC occlusion in 7 (12.6%). In one (1.7%), filter thrombus progressed to IVC occlusion. Filter thrombus remained stable in 16 (28.6%). There was no significant difference in thrombus regression or progression rates whether or not the patients received anticoagulation for filter thrombus. In conclusion, asymptomatic thrombus in the filter is common and it rarely progresses to complete caval occlusion. Anticoagulation has little effect on the resolution of filter thrombosis and future occurrence of PE.« less
Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jha, V. M., E-mail: vjha@mfa.gwu.ed; Lee-Llacer, J.; Williams, J.
Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not anmore » IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less
Stavropoulos, S William; Ge, Benjamin H; Mondschein, Jeffrey I; Shlansky-Goldberg, Richard D; Sudheendra, Deepak; Trerotola, Scott O
2015-06-01
To evaluate the use of endobronchial forceps to retrieve tip-embedded inferior vena cava (IVC) filters. This institutional review board-approved, HIPAA-compliant retrospective study included 114 patients who presented with tip-embedded IVC filters for removal from January 2005 to April 2014. The included patients consisted of 77 women and 37 men with a mean age of 43 years (range, 18-79 years). Filters were identified as tip embedded by using rotational venography. Rigid bronchoscopy forceps were used to dissect the tip or hook of the filter from the wall of the IVC. The filter was then removed through the sheath by using the endobronchial forceps. Statistical analysis entailed calculating percentages, ranges, and means. The endobronchial forceps technique was used to successfully retrieve 109 of 114 (96%) tip-embedded IVC filters on an intention-to-treat basis. Five failures occurred in four patients in whom the technique was attempted but failed and one patient in whom retrieval was not attempted. Filters were in place for a mean of 465 days (range, 31-2976 days). The filters in this study included 10 Recovery, 33 G2, eight G2X, 11 Eclipse, one OptEase, six Option, 13 Günther Tulip, one ALN, and 31 Celect filters. Three minor complications and one major complication occurred, with no permanent sequelae. The endobronchial forceps technique can be safely used to remove tip-embedded IVC filters. © RSNA, 2014.
Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ha, Thuong G. Van; Chien, Andy S.; Funaki, Brian S.
The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonarymore » embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.« less
Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J
2018-05-01
Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P < .001), and force was distributed at significantly different rates (P < .001) during expansion. The largest radial expansion force at minimal caval diameter was seen in the Cook Platinum filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.
Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M
2017-08-01
Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.
Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki
2014-02-01
Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Günther Tulip and Celect IVC filters in multiple-trauma patients.
Rosenthal, David; Kochupura, Paul V; Wellons, Eric D; Burkett, Allison B; Methodius-Rayford, Walaya C
2009-08-01
To evaluate results with the retrievable Günther Tulip (GT) and Celect inferior vena cava filters (IVCFs) placed at the intensive care unit (ICU) bedside under "real-time" intravascular ultrasound (IVUS) guidance in multiple-trauma patients. Between December 2004 and December 2008, 187 multiple-trauma patients (109 men; mean age 44+/-2 years, range 17-71) with contraindications to low-dose anticoagulation therapy or sequential compression devices had Günther Tulip (n = 97) or Celect (n = 90) retrievable IVCFs placed under real-time IVUS guidance. Günther Tulip filters were inserted using a "double-puncture" technique. The Celect IVCFs were placed with a simplified single-puncture technique in which the filter introducer sheath was advanced until the radiopaque tip "covered" the IVUS image of the renal vein, indicating that the filter sheath was in position for filter deployment. The 2 filter groups were compared on the endpoints of technical implantation success, retrievability, prevention of PE, and procedure-related deep vein thrombosis (DVT). As verified by abdominal radiography, 93.1% (174/187) of IVCFs were placed without complications; 6 IVCFs (all GT; p = 0.03 versus Celect) were misplaced in the iliac vein but uneventfully retrieved and replaced in the IVC within 24 hours. Two insertion site femoral vein DVTs (both in the dual puncture group; p>0.2) and 5 groin hematomas occurred during follow-up. GT filters were in place a mean of 107 days and Celect 97 days. In this time, 2 pulmonary embolisms occurred (1 in each group; p>0.2). Of the 115 filters scheduled for retrieval (50 Günther Tulip, 65 Celect), 33 (23 Günther Tulip, 10 Celect) could not be retrieved (p = 0.0004). Vena cavography identified filter tilting (>20 degrees ) in 21 cases (15 GT, 6 Celect), while 12 filters (8 GT, 4 Celect) had extended indwell times (mean 187 days) and excessive tissue ingrowth covering the retrieval hook. Subjectively, the Celect filters were clinically "easier" to retrieve; they also had fewer cases of significant tilt (>20%) than the GT filters, but the difference was not statistically significant. GT and Celect IVCFs placed at the ICU bedside under IVUS guidance in multiple-trauma patients was simple, safe, and avoided transporting critically ill patients out of the ICU. Further investigation of the single sheath IVUS technique and the role of retrievable IVCFs in multi-trauma patients is warranted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalva, Sanjeeva P., E-mail: skalva@partners.org; Athanasoulis, Christos A.; Fan, C.-M.
The purpose of the study was to assess the clinical safety and efficacy of the 'Recovery{sup TM}' (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a 'Recovery{sup TM}' IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. 'Recovery' filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean:more » 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following 'Recovery' filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharifi, Mohsen, E-mail: seyedmohsensharifi@yahoo.com; Bay, Curt; Skrocki, Laura
Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receivemore » an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.« less
Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk
Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less
Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.
Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin
2016-12-01
Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E
2015-05-01
Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.
Complications and Retrieval Data of Vena Cava Filters Based on Specific Infrarenal Location.
Tullius, Thomas G; Bos, Aaron S; Patel, Mikin V; Funaki, Brian; Van Ha, Thuong G
2018-02-01
Although recommended placement of IVC filters is with their tips positioned at the level of the renal vein inflow, in practice, adherence is limited due to clinical situation or IVC anatomy. We seek to evaluate the indwelling and retrieval complications of IVC filters based on their specific position within the infrarenal IVC. Retrospective, single institution study of 333 consecutive infrarenal vena cava filters placed by interventional radiologists in patients with an average age of 62.2 ± 15.7 years was performed between 2013 and 2015. Primary indication was venous thromboembolic disease (n = 320, 96.1%). Filters were classified based on location of the apex below the lowest renal vein inflow on the procedural venogram: less than 1 cm (n = 180, 54.1%), 1-2 cm (n = 96, 28.8%), and greater than 2 cm (n = 57, 17.1%). Denali (n = 171, 51.4%) and Celect (n = 162, 48.6%) filters were evaluated. CT follow-up, indwelling complications, and retrieval data were obtained. Follow-up CT imaging performed for symptomatic indications occurred for 38.3% of filters placed < 1 cm below the lowest renal vein, 27.1% of filters placed 1-2 cm, and 36.8% placed > 2 cm (p = .16). There was no difference in caval strut penetration, penetration of adjacent viscera, time to penetration, filter migration, or tilt (p = .15, .27, .41, .57, .93). No filter fractures occurred. There was no difference in the incidence of breakthrough PE or complex filter retrieval (p = .83, .59). Only one retrieval failure occurred. This study suggests filter apex location within the infrarenal IVC, including placement > 2 cm below the level of the renal vein inflow, is not associated with differences in indwelling or retrieval complications. Level 3 non-randomized controlled follow-up study.
Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data
Molvar, Christopher
2012-01-01
Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414
Mechanisms of Günther Tulip filter tilting during transfemoral placement.
Matsui, Y; Horikawa, M; Ohta, K; Jahangiri Noudeh, Y; Kaufman, J A; Farsad, K
The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-01-01
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665
Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu
We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationshipmore » correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.« less
Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M
2016-12-01
To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.
Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H
2018-05-01
This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.
Behavioural consequences of IVC cages on male and female C57BL/6J mice.
Logge, W; Kingham, J; Karl, T
2013-05-01
Recent developments in the technology to breed and house laboratory rodents for medical research has produced individually ventilated cage (IVC) systems. These IVC systems produce a cage environment significantly different to conventional cages. As it is not known in detail whether housing mice in IVCs impacts on their baseline and drug-induced behaviours compared to mice of conventional filter-top cages a comprehensive multi-tiered phenotyping strategy was used to test the behavioural consequences of IVC housing in male and female C57BL/6JArc mice. IVC had anxiety-like effects in the elevated plus maze, which were more pronounced in female mice whereas cognition and locomotion of all test mice were not modified by IVC housing. Mice raised in IVC cage systems were socially more active than mice of filter-top systems. Furthermore, males raised in IVC exhibited an increased sensitivity to the locomotor-stimulating effects of acute MK-801 treatment compared to males in conventional cages. In summary, this is the first study revealing the longer-term effects of IVC housing on social behaviours and the locomotor response to an acute MK-801 challenge. In conclusion, researchers upgrading their holding facilities to IVC housing may encounter a shift in experimental outcomes (e.g. post pharmacological challenges) and the behavioural phenotype of test mice. Furthermore, differences between the housing conditions of breeding facilities and test facilities must carefully be considered. Finally, researchers should clarify in detail the type of housing test animals have been exposed to when publishing experimental animal research data. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Robotic-Assisted Inferior Vena Cava Filter Retrieval.
Owji, Shahin; Lu, Tony; Loh, Thomas M; Schwein, Adeline; Lumsden, Alan B; Bismuth, Jean
2017-01-01
Although anticoagulation remains the mainstay of therapy for patients with venous thromboembolism, guidelines recommend the use of inferior vena cava (IVC) filters in those who fail anticoagulation or have contraindications to its use. Short-term use of filters has proven effective in reducing the rate of pulmonary embolism. However, their extended use is associated with a variety of complications such as thrombosis, filter migration, or caval perforation, thus making a case for timely filter retrieval. This is the case of a 68-year-old female with a history of chronic oral anticoagulation use for multiple deep venous thrombi (DVT) and pulmonary emboli (PE) who required cervical and thoracic spinal intervention for spondylosis and foramina stenosis. Given her increased risk of recurrent DVT and PE perioperatively, we elected to place a Cook Celect ™ IVC filter (Cook Medical, Bloomington, IN) after oral anticoagulation was stopped for the procedure. Her treatment course was prolonged due to wound-healing complications. We elected to use the Magellan Robotic Catheter System (Hansen Medical, Mountain View, CA) for filter retrieval when she presented 6 months later with caval perforation from the filter struts. With its ease of use, superior mechanical stability, and maneuverability, robot-assisted IVC filter retrieval may be a safer and more reliable substitute for traditional navigation techniques when presented with challenging filter retrievals.
Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T
2018-06-01
To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.
Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pellerin, O., E-mail: olivier.pellerin@egp.aphp.f; Barral, F. G.; Lions, C.
Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days)more » through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.« less
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-06-04
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Tapson, Victor F; Hazelton, Joshua P; Myers, John; Robertson, Claudia; Gilani, Ramyar; Dunn, Julie A; Bukur, Marko; Croce, Martin A; Peick, Ann; West, Sonlee; Lottenberg, Lawrence; Doucet, Jay; Miller, Preston R; Crookes, Bruce; Gandhi, Rajesh R; Croft, Chasen A; Manasia, Anthony; Hoey, Brian A; Lieberman, Howard; Guillamondegui, Oscar D; Novack, Victor; Piazza, Gregory; Goldhaber, Samuel Z
2017-09-01
To evaluate efficacy and safety of a novel device that combines an inferior vena cava (IVC) filter and central venous catheter (CVC) for prevention of pulmonary embolism (PE) in critically ill patients. In a multicenter, prospective, single-arm clinical trial, the device was inserted at the bedside without fluoroscopy and subsequently retrieved before transfer from the intensive care unit (ICU). The primary efficacy endpoint was freedom from clinically significant PE or fatal PE 72 hours after device removal or discharge, whichever occurred first. Secondary endpoints were incidence of acute proximal deep venous thrombosis (DVT), catheter-related thrombosis, catheter-related bloodstream infections, major bleeding events, and clinically significant thrombus (occupying > 25% of volume of filter) detected by cavography before retrieval. The device was placed in 163 critically ill patients with contraindications to anticoagulation; 151 (93%) were critically ill trauma patients, 129 (85%) had head or spine trauma, and 102 (79%) had intracranial bleeding. The primary efficacy endpoint was achieved for all 163 (100%) patients (95% confidence interval [CI], 97.8%-100%, P < .01). Diagnosis of new or worsening acute proximal DVT was time dependent with 11 (7%) occurring during the first 7 days. There were no (0%) catheter-related bloodstream infections. There were 5 (3.1%) major bleeding events. Significant thrombus in the IVC filter occurred in 14 (8.6%) patients. Prophylactic anticoagulation was not initiated for a mean of 5.5 days ± 4.3 after ICU admission. This novel device prevented clinically significant and fatal PE among critically ill trauma patients with low risk of complications. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Stavropoulos, S William; Chen, James X; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Abdel Aal, Ahmed Kamel; Lansky, Alexandra; Muhs, Bart E
2016-10-01
To report the final 2-year data on the efficacy and safety of a nitinol retrievable inferior vena cava (IVC) filter for protection against pulmonary embolism (PE). This was a prospective multicenter trial of 200 patients with temporary indications for caval filtration who underwent implantation of the Denali IVC filter. After filter placement, all patients were followed for 2 years after placement or 30 days after filter retrieval. The primary endpoints were technical success of filter implantation in the intended location and clinical success of filter placement and retrieval. Secondary endpoints were incidence of clinically symptomatic recurrent PE, new or propagating deep vein thrombosis (DVT), and filter-related complications including migration, fracture, penetration, and tilt. Filter placement was technically successful in 199 patients (99.5%). Filters were clinically successful in 190 patients (95%). The rate of PE was 3% (n = 6), with 5 patients having a small subsegmental PE and 1 having a lobar PE. New or worsening DVT was noted in 26 patients (13%). Filter retrieval was attempted 125 times in 124 patients and was technically successful in 121 patients (97.6%). The mean filter dwell time at retrieval was 200.8 days (range, 5-736 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of filter retrieval or during follow-up. The Denali IVC filter exhibited high success rates for filter placement and retrieval while maintaining a low complication rate in this clinical trial. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana
Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less
Inferior Vena Cava Filter Placement and Removal
... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...
Stavropoulos, S William; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Aal, Ahmed Kamel Abdel; Lansky, Alexandra J; Settlage, Richard A; Muhs, Bart E
2014-10-01
To assess safety and effectiveness of a nitinol retrievable inferior vena cava (IVC) filter in patients who require caval interruption to protect against pulmonary embolism (PE). Two hundred patients with temporary indications for an IVC filter were enrolled in this prospective, multicenter clinical study. Patients undergoing filter implantation were to be followed for 2 years or for 30 days after filter retrieval. At the time of the present interim report, all 200 patients had been enrolled in the study, and 160 had undergone a retrieval attempt or been followed to 6 months with their filter in place. Primary study endpoints included technical and clinical success of filter placement and retrieval. Patients were also evaluated for recurrent PE, new or worsening deep vein thrombosis, and filter migration, fracture, penetration, and tilt. Clinical success of placement was achieved in 94.5% of patients (172 of 182), with a one-sided lower limit of the 95% confidence interval of 90.1%. Technical success rate of filter placement was 99.5%. Technical success rate of retrieval was 97.3%; 108 filters were retrieved in 111 attempts. In two cases, the filter apex could not be engaged with a snare, and one device was engaged but could not be removed. Filter retrievals occurred at a mean indwell time of 165 days (range, 5-632 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of retrieval or 6-month follow-up. In this interim report, the nitinol retrievable IVC filter provided protection against pulmonary embolism, and the device could be retrieved with a low rate of complications. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Inferior Vena Cava Filters to Prevent Pulmonary Embolism: Systematic Review and Meta-Analysis.
Bikdeli, Behnood; Chatterjee, Saurav; Desai, Nihar R; Kirtane, Ajay J; Desai, Mayur M; Bracken, Michael B; Spencer, Frederick A; Monreal, Manuel; Goldhaber, Samuel Z; Krumholz, Harlan M
2017-09-26
Inferior vena cava (IVC) filters are widely used for prevention of pulmonary embolism (PE). However, uncertainty persists about their efficacy and safety. The authors conducted a systematic review and meta-analysis of the published reports on the efficacy and safety of IVC filters. The authors searched PubMed, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov through October 3, 2016, for randomized controlled trials (RCTs) or prospective controlled observational studies of IVC filters versus none in patients at risk of PE. Inverse variance fixed-effects models with odds ratio (OR) as the effect measure were used for primary analyses. Main outcomes included subsequent PE, PE-related mortality, all-cause mortality, and subsequent deep vein thrombosis (DVT). The authors' search retrieved 1,986 studies, of which 11 met criteria for inclusion (6 RCTs and 5 prospective observational studies). Quality of evidence for RCTs was low to moderate. Overall, patients receiving IVC filters had lower risk for subsequent PE (OR: 0.50; 95% confidence interval [CI]: 0.33 to 0.75); increased risk for DVT (OR: 1.70; 95% CI: 1.17 to 2.48); nonsignificantly lower PE-related mortality (OR: 0.51; 95% CI: 0.25 to 1.05); and no change in all-cause mortality (OR: 0.91; 95% CI: 0.70 to 1.19). Limiting the results to RCTs showed similar results. Findings were substantively similar across a wide range of sensitivity analyses. Very few prospective controlled studies, with limited quality of evidence, exist regarding the efficacy and safety of IVC filters. Overall, filters appear to reduce the risk of subsequent PE, increase the risk for DVT, and have no significant effect on overall mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A comparative CFD study of four inferior vena cava filters.
López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc
2018-03-30
Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of 4 different filter models in this realistic IVC geometry. We considered different blood flow rates in the range between V in =20 and V in =80 cm 3 /s, and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models, and we paid a special attention to the total drag force, F d , exerted by the blood flow on the filter surface. This force is the sum of 2 contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The F d force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest V in value investigated, the variation in F d among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, ie, if the patient with a filter implanted is treated with anticoagulant therapy. Copyright © 2018 John Wiley & Sons, Ltd.
Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com
Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less
Post traumatic inferior vena cava thrombosis: A case report and review of literature.
Chakroun, Amine; Nakhli, Mohamed Said; Kahloul, Mohamed; Harrathi, Mohamed Amine; Naija, Walid
2017-01-01
Post traumatic inferior vena cava (IVC) thrombosis is a rare and not well described entity with nonspecific clinical presentation. It remains a therapeutic challenge in traumatic context because of haemorrhagic risk due to anticoagulation. We report a case of IVC thrombosis in an 18 year-old man who presented with liver injury following a traffic crash. The thrombosis was incidentally diagnosed on admission by computed tomography. The patient was managed conservatively without anticoagulation initially considering the increasing haemorrhagic risk. IVC filter placing was not possible because of the unusual localization of the thrombus. Unfractionated heparin was started on the third day after CT scan control showing stability of hepatic lesions with occurrence of a pulmonary embolism. The final outcome was good. The management of post traumatic IVC thrombosis is not well described. Medical approach consists in conservative management with anticoagulation which requires the absence of active bleeding lesions. Surgical treatment is commonly based on thrombectomy under extracorporeal circulation. Interventional vascular techniques have become an important alternative approach for the treatment of many vessel lesions. Their main advantages are the relative ease and speed with which they can be performed. Post traumatic IVC thrombosis is a rare condition. Its management is not well defined. Early anticoagulation should be discussed on a case-by-case basis. Other alternatives such IVC filter or surgical thrombectomy may be used when the bleeding risk is increased. The most serious risk is pulmonary embolism. Outcome can be favorable even with non surgical approaches. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites.
Gerwin, Philip M; Ricart Arbona, Rodolfo J; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S
2017-11-01
We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite-infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method.
PCR Testing of IVC Filter Tops as a Method for Detecting Murine Pinworms and Fur Mites
Gerwin, Philip M; Arbona, Rodolfo J Ricart; Riedel, Elyn R; Henderson, Kenneth S; Lipman, Neil S
2017-01-01
We evaluated PCR testing of filter tops from cages maintained on an IVC system through which exhaust air is filtered at the cage level as a method for detecting parasite- infected and -infested cages. Cages containing 4 naïve Swiss Webster mice received 360 mL of uncontaminated aspen chip or α-cellulose bedding (n = 18 cages each) and 60 mL of the same type of bedding weekly from each of the following 4 groups of cages housing mice infected or infested with Syphacia obvelata (SO), Aspiculuris tetraptera (AT), Myocoptes musculinus (MC), or Myobia musculi (MB) and Radfordia affinis (RA; 240 mL bedding total). Detection rates were compared at 30, 60, and 90 d after initiating bedding exposure, by using PCR analysis of filter tops (media extract and swabs) and testing of mouse samples (fur swab [direct] PCR testing, fecal flotation, anal tape test, direct examination of intestinal contents, and skin scrape). PCR testing of filter media extract detected 100% of all parasites at 30 d (both bedding types) except for AT (α-cellulose bedding, 67% detection rate); identified more cages with fur mites (MB and MC) than direct PCR when cellulose bedding was used; and was better at detecting parasites than all nonmolecular methods evaluated. PCR analysis of filter media extract was superior to swab and direct PCR for all parasites cumulatively for each bedding type. Direct PCR more effectively detected MC and all parasites combined for aspen chip compared with cellulose bedding. PCR analysis of filter media extract for IVC systems in which exhaust air is filtered at the cage level was shown to be a highly effective environmental testing method. PMID:29256370
Can Patients Comprehend the Educational Materials that Hospitals Provide about Common IR Procedures?
Sadigh, Gelareh; Hawkins, C Matthew; O'Keefe, John J; Khan, Ramsha; Duszak, Richard
2015-08-01
To assess the readability of online education materials offered by hospitals describing commonly performed interventional radiology (IR) procedures. Online patient education materials from 402 hospitals selected from the Medicare Hospital Compare database were assessed. The presence of an IR service was determined by representation in the Society of Interventional Radiology physician finder directory. Patient online education materials about (i) uterine artery embolization for fibroid tumors, (ii) liver cancer embolization, (iii) varicose vein treatment, (iv) central venous access, (v) inferior vena cava (IVC) filter placement, (vi) nephrostomy tube insertion, (vii) gastrostomy tube placement, and (viii) vertebral augmentation were targeted and assessed by using six validated readability scoring systems. Of 402 hospitals sampled, 156 (39%) were presumed to offer IR services. Of these, 119 (76%) offered online patient education material for one or more of the eight service lines. The average readability scores corresponding to grade varied between the ninth- and 12th-grade levels. All were higher than the recommended seventh-grade level (P < .05) except for nephrostomy and gastrostomy tube placement. Average Flesch-Kincaid Reading Ease scores ranged from 42 to 69, corresponding with fairly difficult to difficult readability for all service lines except IVC filter and gastrostomy tube placement, which corresponded with standard readability. A majority of hospitals offering IR services provide at least some online patient education material. Most, however, are written significantly above the reading comprehension level of most Americans. More attention to health literacy by hospitals and IR physicians is warranted. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing
2013-06-04
To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.
Jia, Zhongzhi; Fuller, Tyler A; McKinney, J Mark; Paz-Fumagalli, Ricardo; Frey, Gregory T; Sella, David M; Van Ha, Thuong; Wang, Weiping
2018-05-01
To investigate the use of retrievable inferior vena cava (IVC) filters in the current practice and analyze the causes of filter left in situ despite initial plans for retrieval. A systematic search of all English-language studies of retrievable IVC filters was conducted, including clinical trials and observational studies published between January 1984 and March 2016. A total of 103 studies were identified, including 10 filter models in 20,319 patients. Placement indications were reported for 11,128 (54.8%) patients, including therapeutic (n = 6270; 56.3%) and prophylactic (n = 4858; 43.7%) indications. A total of 13,224 (65.1%) filters were left as permanent devices; 7095 (34.9%) filters were removed. The reasons for filter nonretrieval among the 5308 (40.1%) reported cases were primary permanent indication (21.2%; 1127/5308), death (19.4%; 1031/5308), ongoing pulmonary embolism (PE) protection (19.0%; 1011/5308), failed retrieval (13.7%; 725/5308), loss to follow-up (13.0%; 689/5308), discontinued care (4.4%; 235/5308), physician oversight (4.0%; 213/5308), patient morbidity (2.8%; 149/5308), and patient refusal (2.4%; 128/5308). A total of 7820 patients presented for filter retrieval, and 7095 filters (90.7%) were successfully removed, with a mean indwelling time of 106.6 ± 47.3 days. Breakthrough PE was reported in 2.1% (191/9169) of patients. Filter tilt, recurrent deep vein thrombosis, penetration, IVC thrombosis, migration, and fracture occurred in 7.7% (798/10,348), 7.1% (362/5092), 5.4% (379/7001), 3.9% (345/8788), 1.4% (160/11,679), and 0.5% (50/9509) of patients, respectively. Approximately two-thirds of retrievable filters were not retrieved even though more than 85% of the filters were initially intended for temporary use. The major reasons for filter left in situ despite initial plans for retrieval were death, need for ongoing PE protection, failed retrieval, loss to follow-up, discontinued care, and physician oversight.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melancon, A; Jacobsen, M; Salatan, F
Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GEmore » Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.« less
Feistenauer, Susan; Sander, Ingrid; Schmidt, Jörg; Zahradnik, Eva; Raulf, Monika; Brielmeier, Markus
2014-01-01
Animal allergens constitute a serious health risk in laboratory animal facilities. To assess possibilities for allergen reduction by technical and organizational measures, we studied personnel exposure to mouse urinary aeroallergens in an animal facility with a holding capacity of 30,000 cages. Short-term (2 h) and intermediate-term (12 h) stationary samples (n = 107) and short-term (2 h) personnel samples (n = 119) were collected on polytetrafluorethylene filters by using air pumps. Long-term (14 d) stationary dust samples containing airborne allergens (n = 165) were collected with electrostatic dust fall collectors (EDC). Mouse allergens were quantified by ELISA. Personnel samples were collected during bedding disposal and refilling of clean cages as well as during cage changing with and without use of cage-changing station. Animal rooms were equipped with either open cages, cages with a soft filter top, cages with a rigid filter top (static microisolation caging), or with individually ventilated cages (IVC) with either a sealed or nonsealed lid, each in positive- or negative-pressure mode. Highest personnel allergen exposure was detected during cage change and emptying of soiled cages. Allergen concentrations were lowest in rooms with sealed IVC under positive or negative pressure, with unsealed IVC under negative pressure, and with static microisolation caging. The use of cage-changing stations and a vacuum bedding-disposal system reduced median personnel exposures 14- to 25-fold, respectively. Using sealed IVC and changing stations minimized allergen exposure, indicating that state-of-the-art equipment reduces exposure to mouse allergens and decreases health risks among animal facility personnel. PMID:25199090
A rare nidus for pulmonary thromboembolism after vertebroplasty.
Vallabhajosyula, Saraschandra; Sundaragiri, Pranathi Rao; Bansal, Ojas; Townley, Theresa A
2013-10-23
Percutaneous vertebroplasty is used to treat osteoporotic compression fractures and bone loss due to malignancy. The cement used can serve as a potential nidus for pulmonary thromboembolism (PTE). An 87-year-old woman with recent L2 vertebroplasty presented with abdominal pain and shortness of breath. Thoracoabdominal CT scan revealed extensive bilateral pulmonary emboli associated with a 9 cm cement fragment in the inferior vena cava (IVC) extending proximally from the level of the right superior renal vein, likely secondary to cement leak from the vertebral plexus into the IVC. She refused catheter extraction was managed conservatively. There are 51 reported cases of cement pulmonary embolism. IVC foreign bodies serving as a nidus for PTE have been reported with IVC filters with an incidence of 6.2%. This is the second reported case of vertebroplasty cement serving as a nidus for PTE. Treatment depends on time interval between the procedure and the symptom onset.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu
Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less
Wan, Tsai-Wen; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V.; Singur, Olga A.; Gostev, Vladimir V.; Sidorenko, Sergey V.; Peryanova, Olga V.; Salmina, Alla B.; Reva, Galina V.; Teng, Lee-Jene; Yamamoto, Tatsuo
2016-01-01
ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256’s strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages. PMID:27741255
Wan, Tsai-Wen; Khokhlova, Olga E; Iwao, Yasuhisa; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V; Singur, Olga A; Gostev, Vladimir V; Sidorenko, Sergey V; Peryanova, Olga V; Salmina, Alla B; Reva, Galina V; Teng, Lee-Jene; Yamamoto, Tatsuo
2016-01-01
ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256's strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages.
Olorunsola, Olufoladare G; Kohi, Maureen P; Fidelman, Nicholas; Westphalen, Antonio C; Kolli, Pallav K; Taylor, Andrew G; Gordon, Roy L; LaBerge, Jeanne M; Kerlan, Robert K
2013-04-01
To compare the frequency of vena caval penetration by the struts of the Option and Günther Tulip cone filters on postplacement computed tomography (CT) imaging. All patients who had an Option or Günther Tulip inferior vena cava (IVC) filter placed between January 2010 and May 2012 were identified retrospectively from medical records. Of the 208 IVC filters placed, the positions of 58 devices (21 Option filters, 37 Günther Tulip filters [GTFs]) were documented on follow-up CT examinations obtained for reasons unrelated to filter placement. In cases when multiple CT studies were obtained after placement, each study was reviewed, for a total of 80 examinations. Images were assessed for evidence of caval wall penetration by filter components, noting the number of penetrating struts and any effect on pericaval tissues. Penetration of at least one strut was observed in 17% of all filters imaged by CT between 1 and 447 days following placement. Although there was no significant difference in the overall prevalence of penetration when comparing the Option filter and GTF (Option, 10%; GTF, 22%), only GTFs showed time-dependent penetration, with penetration becoming more likely after prolonged indwelling times. No patient had damage to pericaval tissues or documented symptoms attributed to penetration. Although the Günther Tulip and Option filters exhibit caval penetration at CT imaging, only the GTF exhibits progressive penetration over time. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
Pussepitiya, Kumari; Samarasinghe, Bandula; Wickramasinghe, Nuwan
2016-01-01
Introduction. Vitelline artery remnants are rare causes of intra-abdominal bands leading to bowel obstruction. These bands may be associated with Meckel's diverticulum. Double inferior vena cava (IVC) is a rare presentation and is usually identified incidentally. Case Presentation. A sixty-year-old male presented with progressive vomiting for five days and he was clinically diagnosed with intestinal obstruction. Plain X-ray abdomen showed evidence of small bowel obstruction. CT scan of the abdomen revealed dilated small bowel loops with a small outpouching in the distal ileum with a band like structure attached to it. In the CT, left sided patent IVC draining into the left renal vein was identified. Left external iliac vein was in continuity with the left IVC. Left internal iliac vein was draining into the right IVC. Exploratory laparotomy revealed a Meckel's diverticulum with a band identified as the vitelline remnant attached to its apex and inserting at the anterior abdominal wall near the umbilicus. Discussion. Meckel's diverticulum with vitelline bands, although rare, should be borne in mind in adult patients with intestinal obstruction. Identification of this anomaly can be difficult in imaging studies. Presence of double IVC should be mentioned in the imaging findings to prevent possible catastrophic complications during surgery. PMID:27843667
DOE Office of Scientific and Technical Information (OSTI.GOV)
McConville, R. M., E-mail: richard_mcconville@hotmail.com; Kennedy, P. T.; Collins, A. J.
Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standardmore » anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.« less
Denali, Tulip, and Option Inferior Vena Cava Filter Retrieval: A Single Center Experience.
Ramaswamy, Raja S; Jun, Emily; van Beek, Darren; Mani, Naganathan; Salter, Amber; Kim, Seung K; Akinwande, Olaguoke
2018-04-01
To compare the technical success of filter retrieval in Denali, Tulip, and Option inferior vena cava filters. A retrospective analysis of Denali, Gunther Tulip, and Option IVC filters was conducted. Retrieval failure rates, fluoroscopy time, sedation time, use of advanced retrieval techniques, and filter-related complications that led to retrieval failure were recorded. There were 107 Denali, 43 Option, and 39 Tulip filters deployed and removed with average dwell times of 93.5, 86.0, and 131 days, respectively. Retrieval failure rates were 0.9% for Denali, 11.6% for Option, and 5.1% for Tulip filters (Denali vs. Option p = 0.018; Denali vs. Tulip p = 0.159; Tulip vs. Option p = 0.045). Median fluoroscopy time for filter retrieval was 3.2 min for the Denali filter, 6.75 min for the Option filter, and 4.95 min for the Tulip filter (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p = 0.67). Advanced retrieval techniques were used in 0.9% of Denali filters, 21.1% in Option filters, and 10.8% in Tulip filters (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p < 0.01). Filter retrieval failure rates were significantly higher for the Option filter when compared to both the Denali and Tulip filters. Retrieval of the Denali filter required significantly less amount of fluoroscopy time and use of advanced retrieval techniques when compared to both the Option and Tulip filters. The findings of this study indicate easier retrieval of the Denali and Tulip IVC filters when compared to the Option filter.
Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results.
Reis, Stephen P; Kovoor, Jerry; Sutphin, Patrick D; Toomay, Seth; Trimmer, Clayton; Pillai, Anil; Reddick, Mark; Kalva, Sanjeeva P
2016-08-01
The purpose of the study is to evaluate the clinical safety and effectiveness of the Denali (Bard, Tempe, Arizona) retrievable inferior vena cava (IVC) filter. In this retrospective study, authors reviewed the data of Denali IVC filters placed at their institution between 2013 and 2015. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. The frequency of post filter pulmonary embolism (PE) and filter-related complications was assessed. Denali filters were placed in 87 patients (47 males; mean age: 56 years). Twenty patients presented with PE, 45 with deep vein thrombosis (DVT), and 21 with both PE and DVT, 1 filter was placed prophylactically before surgery. Indications for filter placement included contraindications to anticoagulation (AC; n = 80), failure of AC (n = 4), and complications of AC (n = 3). No patients had PE on follow-up imaging after filter placement. Retrieval was attempted in 31 patients after a mean period of 125 days (range: 34-324 days). The filter was successfully removed in 31 (100%) patients. Follow-up imaging, available in 71 (82%) patients (range: 2-538 days), demonstrated penetration of 15 legs in 5 patients, caval thrombus in 3, 1 resulting in caval occlusion, <15° filter tilt in 5, and no leg fractures or crossed legs. The Denali filter is safe during deployment and readily retrievable. The overall safety following deployment is similar to those reported in the literature, and the incidence of filter fractures and migration appears to be less than the previous generation of Bard devices. © The Author(s) 2016.
Woodruff, Daniel Y; Van Veldhuizen, Peter; Muehlebach, Gregory; Johnson, Phillip; Williamson, Timothy; Holzbeierlein, Jeffrey M
2013-07-01
Inferior vena caval tumor thrombus (IVC-TT) occurs in 10% of patients diagnosed with renal cell carcinoma (RCC). The perioperative management of these patients remains challenging. Despite multiple publications outlining surgical approaches and outcomes there have been few studies detailing the best peri-operative management of patients with IVC-TT. Our goal was to define the optimal management of patients with RCC and IVC-TT. A review of all published literature regarding the management of RCC with IVC-TT was performed utilizing Pub Med and the Cochrane Database. Reviews were also made of all relevant literature regarding the need for cardiopulmonary bypass and recommendations regarding thrombus in any location in patients with malignancy. Specific items critically examined included: need for preoperative heart catheterization, need for anticoagulation and type of anticoagulation, need for additional studies such as lower extremity duplex or venogram, and indications for vena caval filter placement. The results were then presented to a multidisciplinary group made up of experts in the fields of Urology, Hematology, Oncology, Cardiothoracic Surgery, Interventional Radiology, and Pulmonary/Critical Care. Based on the available literature a best practice guidelines regarding the management of RCC with IVC-TT was established at our institution. Our institutional recommendations include (1) preoperative cardiac catheterization in all patients believed to require cardiopulmonary bypass for removal of the thrombus but only cardiac clearance for those who bypass is unlikely, (2) preoperative anticoagulation using a low molecular weight heparin such as enoxaparin unless contraindicated due to bleeding from the tumor or other contraindication, (3) avoidance of vena caval filters whenever possible is recommended due the potential for caval thrombosis and the difficulties they present during surgical resection. This study identified the available literature on the management of IVC-TT in association with RCC and was carefully reviewed by a multidisciplinary team. As a result, we have established a set of practice guidelines at our institution to help optimally manage patients with renal cell carcinoma and an inferior venal caval thrombus. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izaki, Kenta, E-mail: izaki@med.kobe-u.ac.jp; Yamaguchi, Masato; Matsumoto, Ippei
2011-06-15
A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our techniquemore » for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.« less
Indwelling and Retrieval Complications of Denali and Celect Infrarenal Vena Cava Filters.
Bos, Aaron S; Tullius, Thomas; Patel, Mikin; Leef, Jeffrey A; Navuluri, Rakesh; Lorenz, Jonathan M; Van Ha, Thuong G
2016-07-01
To compare indwelling and retrieval complications of Denali and Celect filters placed in the infrarenal inferior vena cava (IVC). A retrospective study was conducted over 2 years at a single institution in which 171 Denali and 162 Celect filters were placed in 333 patients with a mean age of 62.3 years ± 15.7 (161 men; 48.3%). Filter indications included venous thromboembolic disease (n = 320; 96.1%) and surgical prophylaxis (n = 13; 3.9%). A jugular approach was used to place 303 filters (91.0%). Computed tomography (CT) follow-up, complications, and retrieval data were obtained. Follow-up CT imaging was performed on 58 filters from each group with lower incidences of caval strut penetration (one vs 12) and filter tilt (one vs 15) in the Denali filter group (P = .002 and P < .001, respectively). There was no difference in incidences of breakthrough pulmonary embolism (P = .68). Retrieval attempts were performed on 43 Denali and 53 Celect filters with mean indwelling times at retrieval of 128.2 and 144.1 days, respectively (P = .40). Mean fluoroscopy time at retrieval was lower in the Denali group (3.1 min vs 6.0 min; P = .01). There were fewer cases of complex retrieval in the Denali group (n = 2 vs 10; P = .06). Tilt, fluoroscopy time, and air kerma were associated with complex retrieval (P = .04, P < .001, and P < .001, respectively). There was one Denali filter deployment complication that led to retrieval failure. This study suggests that Denali filters are associated with lower incidences of strut penetration and filter tilt as well as shorter fluoroscopy time at retrieval compared with Celect filters when placed in the infrarenal IVC. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika
The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%)more » had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).« less
Brountzos, Elias N; Binkert, Christoph A; Panagiotou, Irene E; Petersen, Bryan D; Timmermans, Hans; Lakin, Paul C
2004-01-01
We evaluated the clinical outcome of malignant inferior vena cava (IVC) syndrome after intrahepatic IVC stent placement by retrospective analysis of 50 consecutive patients (25 men, 25 women, age 32-83 years) with malignant IVC syndrome who were treated with intrahepatic stent placement. Gianturco-Rosch-Z (GRZ) stents (n = 45), and Wallstents (n = 5) were inserted. Clinical outcome was assessed from patients' records using a score based on leg swelling, scrotal/vulvar edema, ascites and anasarca before and after stent placement, as well as at last follow-up visit before death. Clinical follow-up was supplemented by duplex sonography in 36 patients. Inferior venocavography was performed in 5 patients prior to re- intervention. Follow-up time ranged from 1 to 932 days (mean 62 days). Mean pressure gradient in the IVC was reduced from 14 +/- 4.1 mmHg before to 2.9 +/- 3.2 mmHg after stent placement (p < 0.001). Four patients had stent occlusion, 2 of whom were successfully re-stented. Primary and secondary patency was 59% and 100%, respectively at 540 days. Immediate clinical data were available in 44 patients: 38 improved; 6 did not respond. Last follow-up visit data were available in 36 patients: 24 showed persistent symptom relief till death. All symptom scores were significantly improved after stent placement (p < 0.001) and with the exception of ascites, remained significantly improved (p < 0.05) until the last follow-up. Increased serum bilirubin was a common characteristic of clinical failures and recurrences. Intrahepatic IVC stent placement resulted in significant symptomatic relief in patients with malignant IVC syndrome. Palliation was effective even in patients with a very short life expectancy.
Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele
2017-02-01
Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.
Tam, Matthew D; Spain, James; Lieber, Michael; Geisinger, Michael; Sands, Mark J; Wang, Weiping
2012-02-01
To report the occurrence of fracture of the Recovery filter and incidence of potentially life-threatening complications associated with fractured fragment migration. A retrospective study of images obtained after placement of Recovery inferior vena cava (IVC) filters from 2003 to 2006 was conducted at a single tertiary-care center. Images were reevaluated for fracture and migration; complications related to filter fracture were investigated. Kaplan-Meier survival analysis was performed to investigate the relationship between time in situ and fracture. A total of 363 Recovery filters were placed; 97 were retrieved, leaving 266 filters in situ (135 patients subsequently died of other causes). The following images were evaluated: 130 chest computed tomography (CT) scans, 153 abdominal CT scans, 254 chest radiographs, 148 radiographs of the abdomen/pelvis, and 106 cavagrams. Mean imaging follow-up interval was 18.4 months (maximum, 81.3 mo). No en bloc migration occurred outside the IVC. Twenty-six limb fractures (all short limbs) were identified in 20 patients; the earliest occurred at 4.1 months. Eight fragment migrations occurred into pulmonary arteries, seven into iliac/femoral veins, one into the right ventricle, and one into the renal vein. Seven fragments were intracaval near the filter, one was extracaval, and one could not be located. Kaplan-Meier survival estimates predicted a fracture rate of 40% at 5.5 years. Of the 20 patients with filter fractures, three died of unrelated causes and 17 remain asymptomatic. Recovery filter fractures occurred at the short limb only, with a suggested 5.5-year fracture risk of 40%. No life-threatening events occurred in patients with filter fracture. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Intraventricular Hemorrhage in Adults.
Naff
1999-07-01
Intraventricular hemorrhage (IVH) in adults usually occurs in the setting of aneurysmal subarachnoid hemorrhage or hypertension-related intracerebral hemorrhage. Thus, the underlying cause of IVH is apparent from history and radiographic findings. If the underlying cause of IVH is not apparent, additional studies, including cerebral angiography, magnetic resonance imaging, and toxicology screening, should be performed to identify etiologic agents that may alter management of IVH. Management of IVH is thus done amidst (and must be tempered by) the multiple pharmacologic, surgical, and critical care interventions directed toward the diagnosis and treatment of the underlying cause of IVH. The most immediate threat to life posed by IVH is the development of acute obstructive hydrocephalus. If the hydrocephalus is contributing to a neurologic decline, it must be treated emergently with external ventricular drainage (EVD) through an intraventricular catheter (IVC). The patient with IVH should be evaluated and treated for deficient clotting function before an IVC is inserted. For this purpose, clotting function can be adequately assessed by prothrombin and partial thromboplastin times. Insertion of an IVC may significantly lower intracranial pressure, increasing the transmural pressure difference across the wall of a ruptured cerebral aneurysm and precipitating rerupture of the aneurysm. Therefore, with IVH secondary to a ruptured cerebral aneurysm, it is advisable to delay treatment of hydrocephalus that is not contributing to a neurologic decline until the aneurysm is repaired. Hydrocephalus contributing to significant neurologic decline in the setting of a ruptured aneurysm must be treated immediately despite the unprotected status of the aneurysm. Extreme diligence must be used to allow for the slow, controlled release of cerebrospinal fluid after IVC insertion. This will mitigate the effects of increasing the transmural pressure gradient across the wall of the ruptured aneurysm. In the patient with a neurologic deficit who has IVH-related hydrocephalus and an associated intracerebral hemorrhage, it is best to assume that the hydrocephalus is a significant contributor to the deficit and that it should be treated with EVD. An IVH that is not causing hydrocephalus but is apparently occluding one or both foramina of Monro or the third ventricle should be treated with EVD because obstructive hydrocephalus may develop precipitously and, if unrecognized, may cause irreversible brain damage or death. An IVH that is not likely to cause hydrocephalus because of small volume relative to its location can be followed expectantly. Intraventricular injections of thrombolytic agents through an IVC is a treatment option that may be considered in all patients with IVH that is causing or threatening to cause obstructive hydrocephalus. Unrepaired cerebral aneurysms, untreated cerebral arteriovenous malformations, and clotting disorders are contraindications for this intervention. The surgical evacuation of IVH has a role only in very rare cases in which the IVH is causing a significant mass effect independent of hydrocephalus and associated intraparenchymal brain hemorrhage.
The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ray, Charles E.; Prochazka, Allan
Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauter, Alexander; Triller, Juergen; Schmidt, Felix
Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less
NASA Astrophysics Data System (ADS)
Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin
2012-11-01
The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.
Vukicevic, M; Conover, T; Jaeggli, M; Zhou, J; Pennati, G; Hsia, TY; Figliola, RS
2014-01-01
Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only while the valve leaflets were closed while cycle-averaged pressures improved only slightly (italic>1 mm Hg). Increased pulmonary vascular resistance raised mean circulation pressures but the valve functioned and cardiac output improved and stabilized. Power loss across the TCPC improved by 12–15% (pbold>0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance. PMID:24814833
Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Henshaw, W D; Wang, S L
To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flowmore » in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating/stagnant flow with very low shear stress that may be thrombogenic.« less
Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis
2015-01-01
Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.
Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.
Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel
2015-12-01
We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.
Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701
Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.
The yeast telomerase recruitment module requires a specific RNA architecture.
Laterreur, Nancy; Lemieux, Bruno; Neumann, Hannah; Berger-Dancause, Jean-Christophe; Lafontaine, Daniel; Wellinger, Raymund J
2018-05-18
Telomerases are ribonucleoprotein (RNP) enzymes that are related to reverse transcriptases. While they maintain genome stability, their composition varies significantly between species. Yeast telomerase RNPs contain an RNA that is comparatively large and its overall folding shows long helical segments with distal functional parts. Here we investigated the essential stem IVc module of the budding yeast telomerase RNA, called Tlc1. The distal part of stem IVc includes a conserved sequence element CS2a and structurally conserved features to which bind the Pop1/Pop6/Pop7 proteins and which together function analogously to the P3 domains of the RNase P/MRP RNPs. A more proximal bulged stem with the CS2 element is thought to associate with Est1. Previous data showed that changes in CS2a cause a loss of all of the proteins, not just the Pop-proteins, from stem IVc. The results here show that the association of Est1 with stem IVc indeed requires both the proximal bulged stem and the presence of the Tlc1 P3 domain with the associated Pop-proteins. Separating the P3-domain from the Est1 binding site by inserting only 2 base pairs into the helical stem between the two sites causes a complete loss of Est1 from the RNP and hence a telomerase-negative phenotype in vivo. Still, the distal P3 domain with the associated Pop-proteins remains intact. Moreover, the P3 domain also ensures Est2 stability on the RNP independently of the Est1 association. Therefore, the recruitment module of the Tlc1 RNA requires a very tight architectural organization for telomerase function in vivo. Published by Cold Spring Harbor Laboratory Press for the RNA Society.
Diaz, Jose A.; Alvarado, Christine M.; Wrobleski, Shirley K.; Slack, Dallas W.; Hawley, Angela E.; Farris, Diana M.; Henke, Peter K.; Wakefield, Thomas W.; Myers, Daniel D.
2016-01-01
Summary Previously, we presented the electrolytic inferior vena cava (IVC) model (EIM) during acute venous thrombosis (VT). Here, we present our evaluation of the EIM for chronic VT time points in order to determine whether this model allows for the study of thrombus resolution. C57BU6 mice (n=191) were utilised. In this model a copper-wire, inserted into a 25-gauge needle, is placed in the distal IVC and another subcutaneously. An electrical current (250 µAmp/15 minutes) activates the endothelial cells, inducing thrombogenesis. Ultrasound, thrombus weight (TW), vein wall leukocyte counts, vein wall thickness/fibrosis scoring, thrombus area and soluble P-selectin (sP-sel) were performed at baseline, days 1, 2, 4, 6, 9, 11 and 14, post EIM. A correlation between TW and sP-sel was also determined. A thrombus formed in each mouse undergoing EIM. Blood flow was documented by ultrasound at all time points. IVC thrombus size increased up to day 2 and then decreased over time, as shown by ultrasound, TW, and sP-sel levels. TW and sP-sel showed a strong positive correlation (r=0.48, p<0.0002). Vein wall neutrophils were the most common cell type present in acute VT (up to day 2) with monocytes becoming the most prevalent in chronic VT (from day 6 to day 14). Thrombus resolution was demonstrated by ultrasound, TW and thrombus area. In conclusion, the EIM produces a non-occlusive and consistent IVC thrombus, in the presence of constant blood flow, allowing for the study of VT at both acute and chronic time points. Thrombus resolution was demonstrated by all modalities utilised in this study. PMID:23571406
Thrombogenesis with continuous blood flow in the inferior vena cava. A novel mouse model.
Diaz, José A; Hawley, Angela E; Alvarado, Christine M; Berguer, Alexandra M; Baker, Nichole K; Wrobleski, Shirley K; Wakefield, Thomas W; Lucchesi, Benedict R; Myers, Daniel D
2010-08-01
Several rodent models have been used to study deep venous thrombosis (DVT). However, a model that generates consistent venous thrombi in the presence of continuous blood flow, to evaluate therapeutic agents for DVT, is not available. Mice used in the present study were wild-type C57BL/6 (WT), plasminogen activator inhibitor-1 (PAI-1) knock out (KO) and Delta Cytoplasmic Tail (DCT). An electrolytic inferior vena cava (IVC) model (EIM) was used. A 25G stainless-steel needle, attached to a silver coated copper wire electrode (anode), was inserted into the exposed caudal IVC. Another electrode (cathode) was placed subcutaneously. A current of 250 muAmps over 15 minutes was applied. Ultrasound imaging was used to demonstrate the presence of IVC blood flow. Analyses included measurement of plasma soluble P-selectin (sP-Sel), thrombus weight (TW), vein wall morphometrics, P-selectin and Von Willebrand factor (vWF) staining, transmission electron microscopy (TEM), scanning electron microscopy (SEM); and the effect of enoxaparin on TW was evaluated. A current of 250 muAmps over 15 minutes consistently promoted thrombus formation in the IVC. Plasma sP-Sel was decreased in PAI-1 KO and increased in DCT vs. WT (WT/PAI-1: p=0.003, WT/DCT: p=0.0002). Endothelial activation was demonstrated by SEM, TEM, P-selectin and vWF immunohistochemistry and confirmed by inflammatory cell counts. Ultrasound imaging demonstrated thrombus formation in the presence of blood flow. Enoxaparin significantly reduced the thrombus size by 61% in this model. This EIM closely mimics clinical venous disease and can be used to study endothelial cell activation, leukocyte migration, thrombogenesis and therapeutic applications in the presence of blood flow.
Robotic inferior vena cava surgery.
Davila, Victor J; Velazco, Cristine S; Stone, William M; Fowl, Richard J; Abdul-Muhsin, Haidar M; Castle, Erik P; Money, Samuel R
2017-03-01
Inferior vena cava (IVC) surgery is uncommon and has traditionally been performed through open surgical approaches. Renal cell carcinoma with IVC extension generally requires vena cavotomy and reconstruction. Open removal of malpositioned IVC filters (IVCF) is occasionally required after endovascular retrieval attempts have failed. As our experience with robotic surgery has advanced, we have applied this technology to surgery of the IVC. We reviewed our institution's experience with robotic surgical procedures involving the IVC to determine its safety and efficacy. All patients undergoing robotic surgery that included cavotomy and repair from 2011 to 2014 were retrospectively reviewed. Data were obtained detailing preoperative demographics, operative details, and postoperative morbidity and mortality. Ten patients (6 men) underwent robotic vena caval procedures at our institution. Seven patients underwent robotic nephrectomy with removal of IVC tumor thrombus and retroperitoneal lymph node dissection. Three patients underwent robotic explantation of an IVCF after multiple endovascular attempts at removal had failed. The patients with renal cell carcinoma were a mean age of was 65.4 years (range, 55-74 years). Six patients had right-sided malignancy. All patients had T3b lesions at time of diagnosis. Mean tumor length extension into the IVC was 5 cm (range, 1-8 cm). All patients underwent robotic radical nephrectomy, with caval tumor thrombus removal and retroperitoneal lymph node dissection. The average operative time for patients undergoing surgery for renal cell carcinoma was 273 minutes (range, 137-382 minutes). Average intraoperative blood loss was 428 mL (range, 150-1200 mL). The patients with IVCF removal were a mean age of 33 years (range, 24-41 years). Average time from IVCF placement until robotic removal was 35.5 months (range, 4.3-57.3 months). Before robotic IVCF removal, a minimum of two endovascular retrievals were attempted. Average operative time for patients undergoing IVCF removal was 163 minutes (range, 131-202 minutes). Intraoperative blood loss averaged 250 mL (range, 150-350 mL). All procedures were completed robotically. The mean length of stay for all patients was 3.5 days (range, 1-8 days). All patients resumed ambulation on postoperative day 1. Nine patients resumed a regular diet on postoperative day 2. One patient with a renal tumor sustained a colon injury during initial adhesiolysis, before robotic radical nephrectomy, which was recognized at the initial operation and repaired robotically. Robotic radical nephrectomy and caval tumor removal were then completed. No blood transfusions were required intraoperatively, but three patients required blood transfusions postoperatively. Although robotic IVC surgery is uncommon, our initial limited experience demonstrates it is safe and efficacious. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Brandt, Moritz; Schönfelder, Tanja; Schwenk, Melanie; Becker, Christian; Jäckel, Sven; Reinhardt, Christoph; Stark, Konstantin; Massberg, Steffen; Münzel, Thomas; von Brühl, Marie-Luise; Wenzel, Philip
2014-01-01
Interaction between vascular wall abnormalities, inflammatory leukocytes, platelets, coagulation factors and hemorheology in the pathogenesis of deep vein thrombosis (DVT) is incompletely understood, requiring well defined animal models of human disease. We subjected male C57BL/6 mice to ligation of the inferior vena cava (IVC) as a flow reduction model to induce DVT. Thrombus size and weight were analyzed macroscopically and sonographically by B-mode, pulse wave (pw) Doppler and power Doppler imaging (PDI) using high frequency ultrasound. Thrombus size varied substantially between individual procedures and mice, irrespective of the flow reduction achieved by the ligature. Interestingly, PDI accurately predicted thrombus size in a very robust fashion (r2 = 0.9734, p < 0.0001). Distance of the insertion of side branches from the ligature significantly determines thrombus weight (r2 = 0.5597, p < 0.0001) and length (r2 = 0.5441, p < 0.0001) in the IVC, regardless of the flow measured by pw-Doppler with distances <1.5 mm drastically impairing thrombus formation. Occlusion of side branches prior to ligation of IVC did not increase thrombus size, probably due to patent side branches inaccessible to surgery. Venous side branches influence thrombus size in experimental DVT and might therefore prevent thrombus formation. This renders vessel anatomy and hemorheology important determinants in mouse models of DVT, which should be controlled for.
Continuous air monitor filter changeout apparatus
Rodgers, John C [Santa Fe, NM
2008-07-15
An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.
Cannulation for veno-venous extracorporeal membrane oxygenation
2018-01-01
Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177
Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahrer, Arie; Zippel, Douglas; Garniek, Alexander
The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavographymore » prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.« less
A MEMS disk resonator-based band pass filter electrical equivalent circuit simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sundaram, G. M.; Angira, Mahesh; Gupta, Navneet
In this paper, coupled beam bandpass Disk filter is designed for 1 MHz bandwidth. Filter electrical equivalent circuit simulation is performed using circuit simulators. Important filter parameters such as insertion loss, shape factor and Q factor aresetimated using coventorware simulation. Disk resonator based radial contour mode filter provides 1.5 MHz bandwidth and unloaded quality factor of resonator and filter as 233480, 21797 respectively. From the simulation result it’s found that insertion loss minimum is 151.49 dB, insertion loss maximum is 213.94 dB, and 40 dB shape factor is 4.17.
Kraft, Christiane; Hecking, Carola; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit
2013-07-01
Inferior vena cava (IVC) thrombosis is rare, and data about the clinical presentation of patients are scarce. Therefore, we reviewed all cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described patients characteristics in terms of their clinical presentations in the acute setting of IVC thrombosis. From the MAISTHRO registry, which enrolled 1470 consecutive patients with documented histories of venous thromboembolism, we identified 60 patients (0,4 %; females 60 %) with IVC thrombosis and 888 patients (60.4 %; females 55 %) with isolated lower-extremity deep vein thrombosis (LE-DVT). The median age at the time of IVC thrombosis manifestation was 36.5 years (9 to 83). IVC thrombosis was the initial VTE event in 47 patients (78 %). In the majority of cases, IVC thrombosis extended to the lower-extremity veins, and both lower extremities were affected in 17 cases (28 %). The initial clinical symptom of IVC thrombosis was lower back or abdominal pain which preceded typical symptoms of LE-DVT in 29 (48 %) patients. Symptomatic pulmonary embolism was more frequently observed in IVC thrombosis patients when compared to a sex- and age-matched subgroup of LE-DVT patients, although the difference was not significant (27 % vs. 12 %; p = 0.064). Malignant disease was the only established VTE risk factor with a higher prevalence among IVC thrombosis patients than patients with isolated LE-DVT (27 % vs. 9 %; p = 0.015). Congenital IVC anomalies were identified in another eight IVC thrombosis patients (13 %). IVC thrombosis should be considered a differential diagnosis for inexplicable lower back or abdominal pain especially in young patients. Malignant disease and congenital IVC anomalies seem to be predisposing factors for thrombosis involving the inferior vena cava.
CT Appearance of Traumatic Inferior Vena Cava Injury.
Tsai, Richard; Raptis, Constantine; Schuerer, Douglas J; Mellnick, Vincent M
2016-07-19
CT plays a crucial role in the evaluation of stable patients with blunt and penetrating trauma in the emergency department. Among the more severe injuries that may occur in penetrating and blunt trauma are those to the inferior vena cava (IVC). The purpose of this study was to evaluate and differentiate the CT findings associated with penetrating versus blunt trauma to the IVC to aid the radiologist in diagnosing IVC injuries. Cases of blunt and penetrating IVC injury were retrospectively identified using search queries. Criteria for inclusion were preoperative contrast-enhanced CT and surgically confirmed caval injury or direct findings of caval injury on CT with patient death before surgical confirmation could be obtained. Twelve cases of traumatic IVC injury were identified over a 9-year period: six blunt and six penetrating. The most common finding was a retroperitoneal hematoma, seen in 75% of cases. Eighty-three percent of blunt injuries were associated with hepatic lacerations and contrast material extravasation. Thirty-three percent of penetrating IVC injuries were associated with extravasation. Contour abnormalities were seen in 50% of blunt and 17% of penetrating injuries to the IVC. All three cases of IVC injury resulting in mortality occurred in the retrohepatic segment. Injury to the IVC is frequently fatal in patients with penetrating or blunt trauma. The CT appearance of IVC injury is dichotomous between the two causes, with blunt IVC injury more likely to show extravasation, contour abnormality, and associated hepatic laceration. Injury of the retrohepatic IVC portends a poor outcome. With the continued use of CT for evaluation of trauma patients, the radiologist should be familiar with IVC injury and its different CT appearances.
Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.
Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R
2018-05-03
Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.
Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.
Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji
2018-06-01
To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.
Corl, Keith A; George, Naomi R; Romanoff, Justin; Levinson, Andrew T; Chheng, Darin B; Merchant, Roland C; Levy, Mitchell M; Napoli, Anthony M
2017-10-01
Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients. Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified. Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%). IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qingqiao, E-mail: 1427286069@qq.com; Huang, Qianxin, E-mail: 18705206105@163.com; Shen, Bin, E-mail: 753021357@qq.com
PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or twomore » hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion.« less
Improvement of vertical stabilization on KSTAR
NASA Astrophysics Data System (ADS)
Mueller, D.; Bak, J. G.; Boyer, M. D.; Eideitis, N.; Hahn, S. H.; Humphreys, D. A.; Kim, H. S.; Jeon, Y. M.; Lanctot, M.; Walker, M. L.
2017-10-01
The successful control of strongly shaped plasmas on the Korea Superconducting Tokamak Advanced Research (KSTAR) device requires active feedback of fast motion of the plasma vertical position by the use of internal normal conducting coils (IVC). This has required new electronics to supply relative flux loop differences, for zp, and voltage loop differences, for dzp/dt, as well as a novel technique (Zfast) to use a high-pass filter, typically 1 Hz, on the error in the signal in the feedback loop. Use of Zfast avoids the potential contention encountered when the internal coil attempts to perform control of the plasma shape which should be controlled by the slower and more powerful superconducting coils. A common problem of this contention is saturation of the IVC and loss of fast vertical control. This is eliminated by proper use of the Zfast. A Ziegler-Nichols relay feedback system was used to fine tune the required feedback gains. The selection of the magnetic sensors, filter time constants, control gains and of the Zfast control strategy which allowed vertically stable operation at a plasma elongation, kappa. of up to 2.16 at li = 1.15 and Betap = 2.4 will be discussed which is beyond the design reference of KSTAR of kappa = 2.0 at li = 1.2 and Betap = 1.9. Work Supported by U.S.D.O.E. Contract No. DE-AC02-09CH11466 and DE-SC0010685 and the KSTAR project.
Etiology and VTE risk factor distribution in patients with inferior vena cava thrombosis.
Linnemann, Birgit; Schmidt, Henriette; Schindewolf, Marc; Erbe, Matthias; Zgouras, Dimitrios; Grossmann, Ralf; Schambeck, Christian; Lindhoff-Last, Edelgard
2008-01-01
Inferior vena cava (IVC) thrombosis is a rare event and data detailing the underlying etiology are scarce. Therefore, we reviewed all available cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described the prevalence of VTE risk factors and other conditions contributing to IVC thrombosis development. 53 patients (35 F, 18 M) with IVC thrombosis aged 12 to 79 years were identified. 40 patients (75.5%) developed thrombosis under the age of 45. Local problems, such as IVC anomalies or external venous compression, contributed to the development of thrombosis in 12 cases (22.6%). Lupus anticoagulants (10.9 vs. 2.3%, p=0.013) and malignoma (17.0 vs. 6.4%, p=0.023) were more prevalent in IVC thrombosis patients compared to 265 age and sex matched controls with isolated lower extremity DVT. No difference was identified with regard to inherited thrombophilia or other known VTE risk factors. Symptomatic pulmonary embolism (PE) occurred in 32.1% of IVC thrombosis patients compared to 15.2% of controls (p=0.005). Local problems such as IVC anomalies and external venous compression, malignancy and the presence of lupus anticoagulants contribute to the risk of IVC thrombosis. The risk of symptomatic pulmonary embolism in the acute setting is high.
Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang
2005-01-01
To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.
Two cases of the double inferior venae cavae.
Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S
2000-10-01
Two cases of the double inferior venae cavae (IVC) were found during the student dissection practice in 1997 in Gifu University School of Medicine. On the first case (70-year-old male), the calibers of the right and left IVC were 15 mm and 13 mm, respectively. An anastomosis (4-mm caliber) ran obliquely from the left internal iliac vein to the right IVC. On the second case (86-year-old male), the calibers of the right and left IVC were 15 mm and 10 mm, respectively. We found no anastomosis between the right and left IVC. Each IVC was observed behind the ureter. Both cases belong to Type BC of the classification of McClure and Butler (1925), that is based on the combinations of the right and left IVC, and on their location to the ureters. Both cases also belong to Type II-b-2 of the classification of Takemoto et al. (1978), that is based on the calibers of the right and left IVC and on the running course of the interiliac vein. These are the first and second cases among 808 cadavers in Gifu University School of Medicine and the 93rd and 94th cases in Japan since 1901.
2014-01-01
Objective: The purpose of this study was to review patients who underwent inferior vena cava (IVC) resection with concomitant malignant tumor resection and to consider the operative procedures and the outcomes. Materials and Methods: Between 2000 and 2012, 41 patients underwent resection of malignant tumors concomitant with surgical resection of the IVC at our institute. The records of these patients were retrospectively reviewed. Results: Primary tumor resections included nephrectomy, hepatectomy, retroperitoneal tumor extirpation, lymph node dissection, and pancreaticoduodenectomy. The IVC interventions were partial resection in 23 patients and total resection in 18 patients. Four patients underwent IVC replacement. Operation-related complications included pulmonary embolism, acute myocardial infarction, deep vein thrombosis, leg edema and temporary hemodialysis. There were no operative deaths. The mean follow-up period was 24.9 months (range: 2–98 months). The prognosis depended on the type and stage of the tumor. Conclusion: Resection and reconstruction of the IVC can be performed safely if the preoperative evaluations and surgical procedures are performed properly. The IVC resection without reconstruction was permissive if the IVC was completely obstructed preoperatively, but it may also be considered in cases where the IVC is not completely obstructed. PMID:24995055
Miremad, Seyed Milad; Shirani, Babak
2018-06-01
In this paper, effective energy of pulsed X-Ray emitted from a Mather-type plasma focus device in stored energy of 2.5 kJ with six different anode's insert materials was measured using radiographic method with attenuation filters. Since intensity and energy of X-ray beam were considerably changed with changing the insert material, the method was improved by using different filters simultaneously in all the experiments and selection of the best filter in each experiment according to the appropriate criteria. Effective energy of pulsed X-ray beam was measured 16, 28, 50, 51, 34 and 44 keV when aluminum, copper, zinc, tin, tungsten and lead were used as insert materials, and aluminum, copper, silver, silver, copper and lead were used as filters, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhang, Ji-Gang; Zhang, Dan-Dan; Wu, Xin; Wang, Yu-Zhu; Gu, Sheng-Ying; Zhu, Guan-Hua; Li, Xiao-Yu; Li, Qin; Liu, Gao-Lin
2015-10-28
Studies have described vasculogenic mimicry (VM) as an alternative circulatory system to blood vessels in multiple malignant tumor types, including hepatocellular carcinoma (HCC). In the current study, we aimed to seek novel and more efficient treatment strategies by targeting VM and explore the underlying mechanisms in HCC cells. Cell counting kit-8 (CCK-8) assay and colony survival assay were performed to explore the inhibitory effect of incarvine C (IVC) on human cancer cell proliferation. Flow cytometry was performed to analyze the cell cycle distribution after DNA staining and cell apoptosis by the Annexin V-PE and 7-AAD assay. The effect of IVC on Rho-associated, coiled-coil-containing protein kinase (ROCK) was determined by western blotting and stress fiber formation assay. The inhibitory role of IVC on MHCC97H cell VM formation was determined by formation of tubular network structures on Matrigel in vitro, real time-qPCR, confocal microscopy and western blotting techniques. We explored an anti-metastatic HCC agent, IVC, derived from traditional Chinese medicinal herbs, and found that IVC dose-dependently inhibited the growth of MHCC97H cells. IVC induced MHCC97H cell cycle arrest at G1 transition, which was associated with cyclin-dependent kinase 2 (CDK-2)/cyclin-E1 degradation and p21/p53 up-regulation. In addition, IVC induced apoptotic death of MHCC97H cells. Furthermore, IVC strongly suppressed the phosphorylation of the ROCK substrate myosin phosphatase target subunit-1 (MYPT-1) and ROCK-mediated actin fiber formation. Finally, IVC inhibited cell-dominant tube formation in vitro, which was accompanied with the down-regulation of VM-key factors as detected by real time-qPCR and immunofluorescence. Taken together, the effective inhibitory effect of IVC on MHCC97H cell proliferation and neovascularization was associated with ROCK inhibition, suggesting that IVC may be a new potential drug candidate for the treatment of HCC.
Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A
2013-12-01
Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.
Flat inferior vena cava: indicator of poor prognosis in trauma and acute care surgery patients.
Ferrada, Paula; Vanguri, Poornima; Anand, Rahul J; Whelan, James; Duane, Therese; Wolfe, Luke; Ivatury, Rao
2012-12-01
Flat inferior vena cava (IVC) on ultrasound examination has been shown to correlate with hypovolemic status. We hypothesize that a flat IVC on limited echocardiogram (LTTE) performed in the emergency room (ER) correlates with poor prognosis in acutely ill surgical patients. We conducted a retrospective review of all patients undergoing LTTE in the ER from September 2010 until June 2011. IVC diameter was estimated by subxiphoid window. Flat IVC was defined as diameter less than 2 cm. Fat IVC was defined as diameter greater than 2 cm. Need for intensive care unit admission, blood transfusion requirement, mortality, and need for emergent operation between patients with flat versus Fat IVC were compared. One hundred one hypotensive patients had LTTE performed in the ER. Average age was 38 years. Admission diagnosis was blunt trauma (n = 80), penetrating trauma (n = 13), acute care surgery pathology (n = 7), and burn (n = 1). Seventy-four patients had flat IVC on initial LTTE. Compared with those with fat IVC, flat patients were found have higher rates of intensive care unit admission (51.3 vs 14.8%; P = 0.001), blood transfusion requirement (12.2 vs 3.7%), and mortality (13.5 vs 3.7%). This population also underwent emergent surgery on hospital Day 1 more often (16.2 vs 0%; P = 0.033). Initial flat IVC on LTTE is an indicator of hypovolemia and a predictor of poor outcome.
Xu, Yule; Rong, Ao; Bi, Yanlong; Xu, Wei
2016-01-01
Purpose . To evaluate the efficacy of intravitreal conbercept (IVC) plus modified grid laser photocoagulation (MGP) versus IVC alone for treatment of diffuse diabetic macular edema (DDME). Methods. In this retrospective study, 51 DDME patients were treated with either IVC alone (IVC group) or IVC plus MGP (combined group) with 12 months of follow-up. The clinical records of those patients were reviewed. Results. 26 patients (31 eyes) received IVC alone and 25 patients (30 eyes) received combined therapy. At month 12, the mean best-corrected visual acuity (BCVA) letter score improvement was 9.1 ± 4.5 and 7.5 ± 4.2 in the IVC group and the combined group and the mean central retinal thickness (CRT) reduction was 145.1 ± 69.9 μ m and 168.5 ± 53.6 μ m, respectively. There was no statistically significant difference of improvement in BCVA ( P = 0.164) and decrease in CRT ( P = 0.149) between the two groups. The mean number of injections delivered was significantly higher ( P < 0.001) in the IVC group (5.6 ± 0.8 per eye) than in the combined group (3.3 ± 1.2 per eye). Conclusions . IVC alone or combined with MGP appeared to be effective for treatment of DDME, achieving the similar clinical efficacy. Moreover, MGP helps to reduce the number of injections.
NASA Technical Reports Server (NTRS)
Beyer, T. B.; Powell, C. A.; Daniels, E. F.; Pope, L. D.
1984-01-01
In-flight noise level measurements were made within two cabin configurations of a general aviation business aircraft. The Fairchild Merlin IVC twin-engine aircraft was tested with bare walls and fiberglass insulation and in an executive trim configuration. Narrow-band and octave format data were subjected to analyses which permitted identification of the blade passage harmonics (BPH). Cabin noise level reductions (insertion losses) due to added insulation varied with position in the cabin, the BPH number, cabin pressure, and engine torque. The measurements were closely predicted using the propeller aircraft interior noise (PAIN) mode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nian, H.L.T.; Kuzay, T.M.; Collins, J.
1996-12-31
This paper reports a thermo-mechanical study of a beamline filter (user filter) for undulator/wiggler operations. It is deployed in conjunction with the current commissioning window assembly on the APS insertion device (ID) front ends. The beamline filter at the Advanced Photon Source (APS) will eventually be used in windowless operations also. Hence survival and reasonable life expectancy of the filters under intense insertion device (ID) heat flu are crucial to the beamline operations. To accommodate various user requirements, the filter is configured to be a multi-choice type and smart to allow only those filter combinations that will be safe tomore » operate with a given ring current and beamline insertion device gap. However, this paper addresses only the thermo-mechanical analysis of individual filter integrity and safety in all combinations possible. The current filter design is configured to have four filter frames in a cascade with each frame holding five filters. This allows a potential 625 total filter combinations. Thermal analysis for all of these combinations becomes a mammoth task considering the desired choices for filter materials (pyrolitic graphite and metallic filters), filter thicknesses, undulator gaps, and the beam currents. The paper addresses how this difficult task has been reduced to a reasonable effort and computational level. Results from thermo-mechanical analyses of the filter combinations are presented both in tabular and graphical format.« less
Simonova, G; Rickard, C M; Dunster, K R; Smyth, D J; McMillan, D; Fraser, J F
2012-05-01
Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular catheters (IVC). We compared two adhesives for interaction with IVC material, comparing skin glues with current securement methods in terms of their ability to prevent IVC dislodgement and inhibit microbial growth. Two TAs (Dermabond, Ethicon Inc. and Histoacryl, B. Braun) and three removal agents (Remove™, paraffin and acetone) were tested for interaction with IVC material by use of tensile testing. TAs were also compared against two polyurethane (standard and bordered) dressings (Tegaderm™ 1624 and 1633, 3M Australia Pty Ltd) and an external stabilisation device (Statlock, Bard Medical, Covington) against control (unsecured IVCs) for ability to prevent pull-out of 16 G peripheral IVCs from newborn fresh porcine skin. Agar media containing pH-sensitive dye was used to assess antimicrobial properties of TAs and polyurethane dressings to inhibit growth of Staphylococcus aureus and Staphylococcus epidermidis. Neither TA weakened the IVCs (P >0.05). Of removal agents, only acetone was associated with a significant decrease in IVC strength (P <0.05). Both TAs and Statlock significantly increased the pull-out force (P <0.01). TA was quick and easy to apply to IVCs, with no irritation or skin damage noted on removal and no bacterial colony growth under either TA.
Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati
2018-02-26
The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P < .0001; aorta, r = 0.82-0.86; P < .0001). In children younger than 6 years, the IVC and aorta increase linearly as the children grow. Such normal curves will be beneficial for assessing a pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.
de Sanjosé, Silvia; Alemany, Laia; Ordi, Jaume; Tous, Sara; Alejo, Maria; Bigby, Susan M; Joura, Elmar Armin; Maldonado, Paula; Laco, Jan; Bravo, Ignacio G; Vidal, August; Guimerà, Núria; Cross, Paul; Wain, Gerard V; Petry, Karl Ulrich; Mariani, Luciano; Bergeron, Christine; Mandys, Václav; Sica, Adela Rosa; Félix, Ana; Usubutun, Alp; Seoud, Muhieddine; Hernández-Suárez, Gustavo; Nowakowski, Andrzej Marcin; Wilson, Godfrey; Dalstein, Veronique; Hampl, Monika; Kasamatsu, Elena Sachiko; Lombardi, Luis Estuardo; Tinoco, Leopoldo; Alvarado-Cabrero, Isabel; Perrotta, Myriam; Bhatla, Neerja; Agorastos, Theodoros; Lynch, Charles F; Goodman, Marc T; Shin, Hai-Rim; Viarheichyk, Halina; Jach, Robert; Cruz, M O L Eugenia; Velasco, Julio; Molina, Carla; Bornstein, Jacob; Ferrera, Annabelle; Domingo, Efren Javier; Chou, Cheng-Yang; Banjo, Adekunbiola F; Castellsagué, Xavier; Pawlita, Michael; Lloveras, Belén; Quint, Wim G V; Muñoz, Nubia; Bosch, F Xavier
2013-11-01
Human papillomavirus (HPV) contribution in vulvar intraepithelial lesions (VIN) and invasive vulvar cancer (IVC) is not clearly established. This study provides novel data on HPV markers in a large series of VIN and IVC lesions. Histologically confirmed VIN and IVC from 39 countries were assembled at the Catalan Institute of Oncology (ICO). HPV-DNA detection was done by polymerase chain reaction using SPF-10 broad-spectrum primers and genotyping by reverse hybridisation line probe assay (LiPA25) (version 1). IVC cases were tested for p16(INK4a) by immunohistochemistry (CINtec histology kit, ROCHE). An IVC was considered HPV driven if both HPV-DNA and p16(INK4a) overexpression were observed simultaneously. Data analyses included algorithms allocating multiple infections to calculate type-specific contribution and logistic regression models to estimate adjusted prevalence (AP) and its 95% confidence intervals (CI). Of 2296 cases, 587 were VIN and 1709 IVC. HPV-DNA was detected in 86.7% and 28.6% of the cases respectively. Amongst IVC cases, 25.1% were both HPV-DNA and p16(INK4a) positive. IVC cases were largely keratinising squamous cell carcinoma (KSCC) (N=1234). Overall prevalence of HPV related IVC cases was highest in younger women for any histological subtype. SCC with warty or basaloid features (SCC_WB) (N=326) were more likely to be HPV and p16(INK4a) positive (AP=69.5%, CI=63.6-74.8) versus KSCC (AP=11.5%, CI=9.7-13.5). HPV 16 was the commonest type (72.5%) followed by HPV 33 (6.5%) and HPV 18 (4.6%). Enrichment from VIN to IVC was significantly high for HPV 45 (8.5-fold). Combined data from HPV-DNA and p16(INK4a) testing are likely to represent a closer estimate of the real fraction of IVC induced by HPV. Our results indicate that HPV contribution in invasive vulvar cancer has probably been overestimated. HPV 16 remains the major player worldwide. Copyright © 2013 Elsevier Ltd. All rights reserved.
Outcome of inferior vena cava and noncaval venous leiomyosarcomas.
Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco; Pacilè, Maria Antonietta; Masci, Federica; Vietri, Francesco
2016-02-01
Leiomyosarcoma (LMS) is a rare tumor arising from the smooth muscle cells of arteries and veins. LMS may affect both the inferior vena cava (IVC) and non-IVC veins. Because of its rarity, the experience with the outcome of the disease originating from the IVC compared with that with non-IVC offspring is overall limited. In this study, we compared the clinical features and outcomes after operative resection of IVC and non-IVC LMS to detect possible significant differences that could affect treatment and prognosis. Twenty-seven patients undergoing operative resection of a venous LMS at a single tertiary care center and one secondary care hospital were reviewed retrospectively and divided into 2 groups: IVC-LMS (Group A, n = 18) and non-IVC LMS (Group B, n = 9). As primary end points, postoperative mortality and morbidity, disease-specific survival and, if applicable, patency of venous reconstruction were considered. Bivariate differences were compared with the χ(2) test. Disease-specific survival was expressed by a life-table analysis and compared using the log-rank test. No postoperative mortality was observed in either group. Postoperative morbidity was 28% in group A and 11% in group B (P = .33). The mean duration of follow-up was 60 months (range, 13-140). Disease-specific survival was 60% in group A and 75% in group B at 3 years (P = .48), and it was 54% in group A and 62% in group B at 5 years (P = .63). Seven grafts were occluded in group A (39%) and 1of 3 were occluded in group B (33%) (P = .85). IVC and non-IVC LMS exhibit similar outcomes in terms of postoperative course and survival. Operative resection associated with vascular reconstruction, if applicable, eventually followed by radiation and chemotherapy may be curative and is associated with good functional results. Copyright © 2016 Elsevier Inc. All rights reserved.
York, Jason M.; McDaniel, Allison W.; Blevins, Neil A.; Guillet, Riley R.; Allison, Sarah O.; Cengel, Keith A.; Freund, Gregory G.
2012-01-01
Use of individually ventilated caging (IVC) systems for mouse-based laboratory investigation has dramatically increased. We found that without mice present, intra-cage oxygen concentration was comparable (21%) between IVC housing and ambient environment caging (AEC) that used wire top lids. However, when mice were housed 4-to-a-cage for 1 week, intra-cage oxygen dropped to 20.5% in IVC housing as compared to 21% for AEC housing. IVC intra-cage humidity was also elevated relative to AEC housing. Mice raised in IVC housing as compared to mice raised in AEC housing had higher RBC mass, hematocrit and hemoglobin concentrations. They also had elevated platelet counts but lower white blood cell counts. IVC mice relative to AEC mice had increased saccharin preference and increased fluid consumption but similar locomotion, food intake, social exploration and novel object recognition when tested in an AEC environment. Taken together, these data indicate that ventilated caging systems can have a 0.5% reduction from ambient oxygen concentration that is coupled to mouse red blood cell indices indicative of chronic exposure to a hypoxia. Importantly, IVC housing can impact behavioral testing for depressive-like behavior. PMID:22561683
Indications, complications and outcomes of inferior vena cava filters: A retrospective study.
Wassef, Andrew; Lim, Wendy; Wu, Cynthia
2017-05-01
Inferior vena cava filters are used to prevent embolization of a lower extremity deep vein thrombosis when the risk of pulmonary embolism is thought to be high. However, evidence is lacking for their benefit and guidelines differ on the recommended indications for filter insertion. The study aim was to determine the reasons for inferior vena cava filter placement and subsequent complication rate. A retrospective cohort of patients receiving inferior vena cava filters in Edmonton, Alberta, Canada from 2007 to 2011. Main outcome was the indication of inferior vena cava filter insertion. Other measures include baseline demographic and medical history of patients, clinical outcomes and filter retrieval rates. 464 patients received inferior vena cava filters. An acute deep vein thrombosis with a contraindication to anticoagulation was the indication for 206 (44.4%) filter insertions. No contraindication to anticoagulation could be identified in 20.7% of filter placements. 30.6% were placed in those with active cancer, in which mortality was significantly higher. Only 38.9% of retrievable filters were successfully retrieved. Inferior vena cava filters were placed frequently in patients with weak or no guideline-supported indications for filter placement and in up to 20% of patients with no contraindication to anticoagulation. The high rates of cancer and the high mortality rate of the cohort raise the possibility that some filters are placed inappropriately in end of life settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
Prajapati, Parna; Shah, Pankhil; King, Hollis H; Williams, Arthur G; Desai, Pratikkumar; Downey, H Fred
2010-09-01
Osteopathic lymphatic pump treatments (LPT) are used to treat edema, but their direct effects on lymph flow have not been studied. In the current study, we examined the effects of LPT on lymph flow in the thoracic duct of instrumented conscious dogs in the presence of edema produced by constriction of the inferior vena cava (IVC). Six dogs were surgically instrumented with an ultrasonic flow transducer on the thoracic lymph duct and catheters in the descending thoracic aorta and in IVC. After postoperative recovery, lymph flow and hemodynamic variables were measured 1) pre-LPT, 2) during 4 min LPT, 3) post-LPT, in the absence and presence of edema produced by IVC constriction. This constriction increased abdominal girth from 60 +/-2.6 to 75 +/- 2.9 cm. Before IVC constriction, LPT increased lymph flow (P < 0.05) from 1.9 +/- 0.2 ml/min to a maximum of 4.7 +/-1.2 ml/min, whereas after IVC constriction, LPT increased lymph flow (P < 0.05) from 7.9 +/-2.2 to a maximum of 11.7 +/-2.2 ml/min. The incremental lymph flow mobilized by 4 min of LPT (ie, the flow that exceeded 4 min of baseline flow), was 10.6 ml after IVC constriction. This incremental flow was not significantly greater than that measured before IVC constriction. Edema caused by IVC constriction markedly increased lymph flow in the thoracic duct. LPT increased thoracic duct lymph flow before and after IVC constriction. The lymph flow mobilized by 4 min of LPT in presence of edema was not significantly greater than that mobilized prior to edema.
Chen, Lei; Kim, Yunie; Santucci, Karen A
2007-10-01
Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.
[Leiomyosarcoma of the inferior vena cava: a case report and review].
Yo, Toeki; Taoka, Rikiya; Hanasaki, Takeshi; Nakanishi, Yukako; Togo, Yoshikazu; Suzuki, Toru; Higuchi, Yoshihide; Zozumi, Masataka; Hirota, Seiichi; Kanematsu, Akihiro; Nojima, Michio; Yamamoto, Shingo
2014-03-01
A 37-year-old woman with an incidentally found abdominal mass was referred to our hospital. A fixed, non-tender mass was palpated in the right upper quadrum of her abdomen. There was no elevation of tumor markers. Computed tomography revealed a mass extending from the hepatic vein level to renal hilar level. The tumor completely obstructed the inferior vena cava (IVC). T1-weighted magnetic resonance imaging (MRI) showed that the mass was isointense with muscles. T2-weighted MRI image with contrast medium demonstrated collateral circulation. Upon diagnosis of the IVC tumor, we removed the right kidney and the tumor en bloc without reconstructing IVC. The tumor diameter was 11.6 × 5.5 × 4.7 cm. Pathological examination established a diagnosis of IVC leiomyosarcoma. She is alive without sign of recurrence after operation for seven months. There were 143 reports of IVC leiomyosarcoma in Japan. In 31% of them, IVC was not reconstructed.
Modeling Flow Past a Tilted Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Wang, S L
Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside amore » model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.« less
LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING
2015-01-01
The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424
Tunable Microwave Filter Design Using Thin-Film Ferroelectric Varactors
NASA Astrophysics Data System (ADS)
Haridasan, Vrinda
Military, space, and consumer-based communication markets alike are moving towards multi-functional, multi-mode, and portable transceiver units. Ferroelectric-based tunable filter designs in RF front-ends are a relatively new area of research that provides a potential solution to support wideband and compact transceiver units. This work presents design methodologies developed to optimize a tunable filter design for system-level integration, and to improve the performance of a ferroelectric-based tunable bandpass filter. An investigative approach to find the origins of high insertion loss exhibited by these filters is also undertaken. A system-aware design guideline and figure of merit for ferroelectric-based tunable band- pass filters is developed. The guideline does not constrain the filter bandwidth as long as it falls within the range of the analog bandwidth of a system's analog to digital converter. A figure of merit (FOM) that optimizes filter design for a specific application is presented. It considers the worst-case filter performance parameters and a tuning sensitivity term that captures the relation between frequency tunability and the underlying material tunability. A non-tunable parasitic fringe capacitance associated with ferroelectric-based planar capacitors is confirmed by simulated and measured results. The fringe capacitance is an appreciable proportion of the tunable capacitance at frequencies of X-band and higher. As ferroelectric-based tunable capac- itors form tunable resonators in the filter design, a proportionally higher fringe capacitance reduces the capacitance tunability which in turn reduces the frequency tunability of the filter. Methods to reduce the fringe capacitance can thus increase frequency tunability or indirectly reduce the filter insertion-loss by trading off the increased tunability achieved to lower loss. A new two-pole tunable filter topology with high frequency tunability (> 30%), steep filter skirts, wide stopband rejection, and constant bandwidth is designed, simulated, fabricated and measured. The filters are fabricated using barium strontium titanate (BST) varactors. Electromagnetic simulations and measured results of the tunable two-pole ferroelectric filter are analyzed to explore the origins of high insertion loss in ferroelectric filters. The results indicate that the high-permittivity of the BST (a ferroelectric) not only makes the filters tunable and compact, but also increases the conductive loss of the ferroelectric-based tunable resonators which translates into high insertion loss in ferroelectric filters.
Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.
Chen, Lei; Hsiao, Allen; Langhan, Melissa; Riera, Antonio; Santucci, Karen A
2010-10-01
Prospectively identifying children with significant dehydration from gastroenteritis is difficult in acute care settings. Previous work by our group has shown that bedside ultrasound (US) measurement of the inferior vena cava (IVC) and the aorta (Ao) diameter ratio is correlated with intravascular volume. This study was designed to validate the use of this method in the prospective identification of children with dehydration by investigating whether the IVC/Ao ratio correlated with dehydration in children with acute gastroenteritis. Another objective was to investigate the interrater reliability of the IVC/Ao measurements. A prospective observational study was carried out in a pediatric emergency department (PED) between November 2007 and June 2009. Children with acute gastroenteritis were enrolled as subjects. A pair of investigators obtained transverse images of the IVC and Ao using bedside US. The ratio of IVC and Ao diameters (IVC/Ao) was calculated. Subjects were asked to return after resolution of symptoms. The difference between the convalescent weight and ill weight was used to calculate the degree of dehydration. Greater than or equal to 5% difference was judged to be significant. Linear regression was performed with dehydration as the dependent variable and the IVC/Ao as the independent variable. Pearson's correlation coefficient was calculated to assess the degree of agreement between observers. A total of 112 subjects were enrolled. Seventy-one subjects (63%) completed follow-up. Twenty-eight subjects (39%) had significant dehydration. The linear regression model resulted in an R² value of 0.21 (p < 0.001) and a slope (B) of 0.11 (95% confidence interval [CI] = 0.08 to 0.14). An IVC/Ao cutoff of 0.8 produced a sensitivity of 86% and a specificity of 56% for the diagnosis of significant dehydration. Forty-eight paired measurements of IVC/Ao ratios were made. The Pearson correlation coefficient was 0.76. In this pilot study the ratio of IVC to Ao diameters, as measured by bedside US, was a marginally accurate measurement of acute weight loss in children with dehydration from gastroenteritis. The technique demonstrated good interrater reliability. © 2010 by the Society for Academic Emergency Medicine.
Shoe inserts and orthotics for sport and physical activities.
Nigg, B M; Nurse, M A; Stefanyshyn, D J
1999-07-01
The purposes of this paper were to discuss the perceived benefits of inserts and orthotics for sport activities and to propose a new concept for inserts and orthotics. There is evidence that inserts or orthotics reduce or prevent movement-related injuries. However, there is limited knowledge about the specific functioning an orthotic or insert provides. The same orthotic or insert is often proposed for different problems. Changes in skeletal movement due to inserts or orthotics seem to be small and not systematic. Based on the results of a study using bone pins, one may question the idea that a major function of orthotics or inserts consists in aligning the skeleton. Impact cushioning with shoe inserts or orthotics is typically below 10%. Such small reductions might not be important for injury reduction. It has been suggested that changes in material properties might produce adjustments in the muscular response of the locomotor system. The foot has various sensors to detect input signals with subject specific thresholds. Subjects with similar sensitivity threshold levels seem to respond in their movement pattern in a similar way. Comfort is an important variable. From a biomechanical point of view, comfort may be related to fit, additional stabilizing muscle work, fatigue, and damping of soft tissue vibrations. Based on the presented evidence, the concept of minimizing muscle work is proposed when using orthotics or inserts. A force signal acts as an input variable on the shoe. The shoe sole acts as a first filter, the insert or orthotic as a second filter, the plantar surface of the foot as a third filter for the force input signal. The filtered information is transferred to the central nervous system that provides a subject specific dynamic response. The subject performs the movement for the task at hand. For a given movement task, the skeleton has a preferred path. If an intervention supports/counteracts the preferred movement path, muscle activity can/must be reduced/increased. Based on this concept, an optimal insert or orthotic would reduce muscle activity, feel comfortable, and should increase performance.
Effects of abdominal pressure on venous return: abdominal vascular zone conditions.
Takata, M; Wise, R A; Robotham, J L
1990-12-01
The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.
22 CFR 121.5 - Apparatus and devices under Category IV(c).
Code of Federal Regulations, 2011 CFR
2011-04-01
... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Apparatus and devices under Category IV(c). 121... UNITED STATES MUNITIONS LIST Enumeration of Articles § 121.5 Apparatus and devices under Category IV(c... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...
2013-01-11
Anaplastic Thyroid Cancer; Insular Thyroid Cancer; Metastatic Parathyroid Cancer; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Recurrent Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Non-small Cell Lung Cancer; Recurrent Parathyroid Cancer; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Thyroid Cancer; Recurrent Verrucous Carcinoma of the Larynx; Stage III Follicular Thyroid Cancer; Stage III Papillary Thyroid Cancer; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Larynx; Stage IIIB Non-small Cell Lung Cancer; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Follicular Thyroid Cancer; Stage IVA Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Papillary Thyroid Cancer; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Follicular Thyroid Cancer; Stage IVB Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Papillary Thyroid Cancer; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Follicular Thyroid Cancer; Stage IVC Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Papillary Thyroid Cancer; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Thryoid Gland Nonmedullary Carcinoma; Thyroid Gland Medullary Carcinoma; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary
Hoffer, L John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H
2015-01-01
Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Despite IVC's biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC's value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. ClinicalTrials.gov NCT01050621.
Ren, Ke; Xu, Ke; Sun, Wen-ge; Chen, Yu-shuai; Qi, Xi-xun; Li, Ran-liang; Jin, An-yu
2007-01-20
Budd-Chiari syndrome (BCS) is a rare disease with portal hypertension caused by the blockage of the hepatic vein and/or the inferior vena cava (IVC). Angiography is the "golden standard" for diagnosis, but it is an invasive examination. To assess the diagnostic value of a fresh blood imaging (FBI) relative to BCS, we used a magnetic resonance angiography (MRA) with an FBI sequence for a preoperative evaluation of the BCS patients in this study. Fifty patients who were suspected of having BCS after they had been checked by a B-ultrasound were studied. 2D and 3D FBI were performed on a 1.5T superconductive MR scanner. Original images were rebuilt using a maximal intensity projection (MIP) method on the console. Two doctors reviewed all images before they learned of the angiography results. We then compared the diagnoses obtained from the FBI and angiography results to evaluate the diagnostic value of the FBI. Forty-one patients were diagnosed as BCS and 9 as non-BCS based on an angiography. The FBI correctly diagnosed 38 patients, incorrectly diagnosed 1 patient, and missed diagnosis in 3 patients. Thus, the diagnostic sensitivity of the FBI is 93% (38/41), the specificity is 89% (8/9) and the accuracy is 92% (46/50). The FBI images of the 13 membranous stenoses of the IVC showed a sudden stenosis of the post-liver segment of the IVC. The Images of the 5 patients with a membranous obstruction of the IVC showed IVC thickening and an absence of blood signals in the post-hepatic segment of the IVC. The images of the 4 patients with the segmental thrombosis of the IVC showed abnormal and intermittent signals in the IVC. The images of the 6 patients with a simple hepatic vein obstruction showed obstructive hepatic veins. The images of the 6 patients with the stenosis of both the IVC and the hepatic veins showed the stenosis of the IVC, the thickening of the hepatic veins and the formation of a compensatory circulation within the liver. Lastly, the images of the 7 patients showed a combination of the IVC thrombosis with stenosis or with the obstruction of one or two hepatic veins. An FBI can show a membranous stenosis, and an obstruction and thrombosis of the IVC. In addition, it can also demonstrate the thickening of the flexural hepatic vein and the development of intra-hepatic compensatory branches with slow blood flow. Thus, it can guide the puncturing and opening of the hepatic vein involved in an interventional therapy for BCS patients.
A case of double inferior vena cava with renal, ovarian and iliac vein variation.
Ito, Taro; Ikeda, Yayoi
2018-01-01
We encountered a rare case of an anatomic variant of inferior vena cava (IVC) duplication with renal, ovarian and iliac vein variation in an 81-year-old Japanese female cadaver during a student dissection course of anatomy at Aichi Gakuin University School of Dentistry. The two IVCs ran upwards bilaterally to the abdominal aorta. The left IVC joined with the left renal vein (RV) to form a common trunk that crossed anterior to the aorta and ended at the right IVC. We detected a vein [interiliac vein (IiV)] connecting the two IVCs at the level of the aortic bifurcation. The IiV was formed by the union of two tributaries from the left IVC and a tributary from the left internal iliac vein (IIV) and ran obliquely upwards from left to right. Two right ovarian veins, arising separately from the ipsilateral pampiniform plexus, ran vertically in parallel to each other, and each one independently terminated at the right IVC and the right RV. Two right IIVs, connecting each other with small branches, ascended and separately joined the right external iliac vein. The right and left IIVs were connected to each other. These variations cause abnormal drainage, which could lead to clinical symptoms associated with the dysfunction of the vascular and urogenital systems. Here we describe the detailed anatomical features of the area and discuss the related anatomical and developmental aspects.
Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel
2013-01-01
Background Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Methods Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. Results A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. Conclusions The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. PMID:23458108
Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel
2013-08-01
Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. © 2013 International Hepato-Pancreato-Biliary Association.
Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang
2017-06-01
To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (p<0.001). Evaluation of CTV data sets was significantly facilitated with flexible delayed scan time of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.
Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.
Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A
2018-06-01
Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event. We aimed to develop a murine model to study IVC recurrent VT in mice. An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin. Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content. Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.
Guide wire entrapment by inferior vena cava filters: an experimental study.
Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F
2005-09-01
In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul
Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.
Focal Atrial Tachycardia Arising from the Inferior Vena Cava
Lim, Yeong-Min; Uhm, Jae-Sun
2017-01-01
The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006
A case of left inferior vena cava.
Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S
2001-12-01
A case of left inferior vena cava (IVC) was found in a 72-year-old male cadaver during student dissection practice in 1999 at Gifu University School of Medicine. It was formed by junction of the left and right common iliac veins at the lower left corner of the 5th lumbar vertebra. This IVC (15-mm caliber) ascended 82 mm along the left side of the abdominal aorta dorsally to the ureter. Receiving the left renal vein, it became 21 mm in caliber and ran obliquely upward for 43 mm across the abdominal aorta. As soon as it received two right renal veins at the level of the 2nd lumbar vertebra, the IVC (25-mm caliber) turned directly above. The present case belongs to Type C of the classification of McClure and Butler (1925), which is based on the combinations of the left and right IVCs, and on their location relative to the ureters. The present case also belongs to Type 1 of the classification of Yoshida et al. (1981). We consider that left IVC in the present case is mainly caused by disappearance of the right supracardinal vein and persistence of the left one during the embryological development of the IVC.
Left-sided and duplicate inferior vena cava: a case series and review.
Ang, Wee Choen; Doyle, Terry; Stringer, Mark D
2013-11-01
Left-sided and duplicate inferior vena cava (IVC) are two major anatomical variants within the spectrum of IVC malformations, both of which are developmental abnormalities of the supracardinal veins. Four clinical cases are described to highlight the computed tomographic appearances of these vascular malformations and provide novel data on venous dimensions. A systematic review of the recent literature (2000-2011) was conducted focusing on the anatomy, demographics, and associated pathology (congenital and acquired) of isolated left-sided and duplicate IVC. A total of 73 relevant articles were retrieved, consisting of case reports and small case series. The prevalence of left-sided IVC is about 0.1-0.4% and that for duplicate IVC about 0.3-0.4%; both anomalies show a slight male preponderance. In each condition, there are documented variations in the course and tributaries of the IVC. The clinical importance of these anomalies lies in three principal areas: the potential for misdiagnosis on imaging; technical difficulties during retroperitoneal surgery (particularly abdominal aortic aneurysm repair and live donor nephrectomy); and their significance in relation to the etiology and management of venous thromboembolism. Copyright © 2012 Wiley Periodicals, Inc.
Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi
2013-09-01
There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.
2018-01-12
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage IIIA Non-small Cell Lung Cancer; Stage IIIB Non-small Cell Lung Cancer; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary
2017-02-23
Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Major Salivary Gland Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Major Salivary Gland Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Major Salivary Gland Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma
Miyake, Hideaki; Sugiyama, Takayuki; Aki, Ryota; Matsushita, Yuto; Tamura, Keita; Motoyama, Daisuke; Ito, Toshiki; Otsuka, Atsushi
2018-06-01
To evaluate the oncological outcomes of patients with metastatic renal cell carcinoma (mRCC) involving the inferior vena cava (IVC) who received cytoreductive nephrectomy. This study included 75 consecutive metastatis renal cell carcinoma (mRCC) patients with inferior vena cava (IVC) tumor thrombus undergoing cytoreductive nephrectomy and tumor thrombectomy followed by systemic therapy. Of the 75 patients, 11, 33, 24 and 7 had level I, II, III and IV IVC thrombus, respectively. Following surgical treatment, 25 (group A), 27 (group B) and 23 (group C) received cytokine therapy alone, molecular-targeted therapy alone and both therapies, respectively, as management for metastatic diseases. The median overall survival (OS) of the 75 patients was 16.2 months. No significant differences in OS were noted according to the level of the IVC tumor thrombus. There were no significant differences in OS among groups A, B and C; however, OS in groups B and C was significantly superior to that in group A. Furthermore, multivariate analysis of several parameters identified the following independent predictors of poor OS-elevated C-reactive protein, liver metastasis and postoperative treatment with cytokine therapy alone. The prognosis of mRCC patients with IVC thrombus undergoing cytoreductive nephrectomy may be significantly affected by the type of postoperative systemic therapy rather than the level of the IVC tumor thrombus. Accordingly, cytoreductive nephrectomy should be considered as a major therapeutic option for patients with mRCC involving the IVC, particularly in the era of targeted therapy.
Fontan completion in patients with atrial isomerism and separate hepatic venous drainage.
Nakata, Tomohiro; Fujimoto, Yoshifumi; Hirose, Keiichi; Osaki, Masaki; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sakamoto, Kisaburo
2010-06-01
Fontan completion in patients with atrial isomerism, in which the inferior vena cava (IVC) and the hepatic vein (HV) drain separately, is technically challenging. Herein, we review our surgical approach to these patients. The medical records of 50 consecutive patients with atrial isomerism who underwent Fontan completion between 1998 and 2008 were reviewed retrospectively. Separate HV drainage was present in 17 patients. Patients with interrupted IVC were excluded. Patient characteristics were as follows: median age, 26 months (range 15-149); median weight, 9.6 kg (range 8.1-47.2); right atrial isomerism, 16 patients; and left atrial isomerism, one. The IVC and the separate HV at the level of diaphragm were contralateral in 16 patients, and ipsilateral in one. The surgical procedures for directing blood flow from the IVC and the separate HV to the pulmonary arteries were as follows: en bloc resection of the IVC and the HV and anastomosing these veins to an extracardiac conduit in 10 patients; connecting the IVC to the HV in a side-to-side fashion before anastomosing them to an extracardiac conduit in one; and lateral tunnel in another. When the IVC and the HV were widely separated by the vertebrae, we chose an intra-extracardiac conduit (intra-atrial septation) in four patients and an extracardiac conduit for the IVC and the right HV and lateral tunnel for the separate left HV in one. There was no mortality. Five re-operations were performed (pacemaker in two patients; one each of fenestration, release of outflow obstruction and ligation of collateral arteries). Sixteen patients underwent follow-up catheterisation, which revealed central venous pressure of 12.0 + or - 2.0 mmHg and arterial oxygen saturation of 92% + or - 6%. The mid-term results of the Fontan completion in patients with atrial isomerism and separate HV drainage were excellent. The distance between the IVC and the separate HV and the position of the vertebrae should be considered when choosing a surgical technique. Copyright 2010. Published by Elsevier B.V.
Doody, Kevin J; Broome, E Jason; Doody, Kathleen M
2016-04-01
The purpose of this study is to to compare the efficacy of intravaginal culture (IVC) of embryos in INVOcell™ (INVO Bioscience, MA, USA) to traditional in vitro fertilization (IVF) incubators in a laboratory setting using a mild pre-determined stimulation regimen based solely on anti-mullerian hormone (AMH) and body weight with minimal ultrasound monitoring. The primary endpoint examined was total quality blastocysts expressed as a percentage of total oocytes placed in incubation. Secondary endpoints included percentage of quality blastocysts transferred, pregnancy, and live birth rates. In this prospective randomized open-label controlled single-center study, 40 women aged <38 years of age with a body mass index (BMI) of <36 and an AMH of 1-3 ng/mL were randomized prior to trigger to receive either IVC or IVF. Controlled ovarian stimulation was administered with human menopausal gonadotropin (hMG) in a fixed gonadotropin-releasing hormone (GnRH) agonist cycle based solely on AMH and body weight. A single ultrasound-monitoring visit was performed on the 10th day of stimulation. One or two embryos were transferred following 5 days of culture. IVF produced a greater percentage of total quality embryos as compared to IVC (50.6 vs. 30.7 %, p = 0.0007, respectively). There was no significant difference between in IVF and IVC in the percentage of quality blastocysts transferred (97.5 vs. 84.9 %, p = 0.09) or live birth rate (60 % IVF, 55 % IVC). IVF was shown to be superior to IVC in creating quality blastocysts. However, both IVF and IVC produced identical blastocysts for transfer resulting in similar live birth rates. IVC using INVOcell™ is effective and may broaden access to fertility care in selected patient populations by ameliorating the need for a traditional IVF laboratory setting. Further studies will help elucidate the potential physiological, psychological, geographic, and financial impact of IVC on the delivery of fertility care.
Charbonneau, Hélène; Riu, Béatrice; Faron, Matthieu; Mari, Arnaud; Kurrek, Matt M; Ruiz, Jean; Geeraerts, Thomas; Fourcade, Olivier; Genestal, Michèle; Silva, Stein
2014-09-05
Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients. Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%). Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity. ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.
Performance evaluation of MPEG internet video coding
NASA Astrophysics Data System (ADS)
Luo, Jiajia; Wang, Ronggang; Fan, Kui; Wang, Zhenyu; Li, Ge; Wang, Wenmin
2016-09-01
Internet Video Coding (IVC) has been developed in MPEG by combining well-known existing technology elements and new coding tools with royalty-free declarations. In June 2015, IVC project was approved as ISO/IEC 14496-33 (MPEG- 4 Internet Video Coding). It is believed that this standard can be highly beneficial for video services in the Internet domain. This paper evaluates the objective and subjective performances of IVC by comparing it against Web Video Coding (WVC), Video Coding for Browsers (VCB) and AVC High Profile. Experimental results show that IVC's compression performance is approximately equal to that of the AVC High Profile for typical operational settings, both for streaming and low-delay applications, and is better than WVC and VCB.
Performance of a high Tc superconducting ultralow-loss microwave stripline filter
NASA Technical Reports Server (NTRS)
Zahopoulos, C.; Sridhar, S.; Bautista, J. J.; Ortiz, G.; Lanagan, M.
1991-01-01
The successful fabrication is reported of a five-pole interdigital stripline filter made of the 93 K superconductor Y1Ba2Cu3O(y) coated on a silver substrate, with a center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest insertion loss measured was 0.1 dB at 12 K, with a return loss better than 16 dB, representing significant improvements over a similar Cu filter, and comparable to low Tc filters. The insertion loss appears to be limited by extrinsic factors such as tuning mismatch and joint losses, and not by the superconducting material losses.
2017-03-22
Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma
Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei
2018-05-30
To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.
Ultrasound assessment of severe dehydration in children with diarrhea and vomiting.
Levine, Adam C; Shah, Sachita P; Umulisa, Irenee; Munyaneza, Richard B Mark; Dushimiyimana, Jean Marie; Stegmann, Katrina; Musavuli, Juvenal; Ngabitsinze, Protogene; Stulac, Sara; Epino, Henry M; Noble, Vicki E
2010-10-01
The objective of this study was to determine the test characteristics for two different ultrasound (US) measures of severe dehydration in children (aorta to inferior vena cava [IVC] ratio and IVC inspiratory collapse) and one clinical measure of severe dehydration (the World Health Organization [WHO] dehydration scale). The authors enrolled a prospective cohort of children presenting with diarrhea and/or vomiting to three rural Rwandan hospitals. Children were assessed clinically using the WHO scale and then underwent US of the IVC by a second clinician. All children were weighed on admission and then fluid-resuscitated according to standard hospital protocols. A percent weight change between admission and discharge of greater than 10% was considered the criterion standard for severe dehydration. Receiver operating characteristic (ROC) curves were created for each of the three tests of severe dehydration compared to the criterion standard. Children ranged in age from 1 month to 10 years; 29% of the children had severe dehydration according to the criterion standard. Of the three different measures of dehydration tested, only US assessment of the aorta/IVC ratio had an area under the ROC curve statistically different from the reference line. At its best cut-point, the aorta/IVC ratio had a sensitivity of 93% and specificity of 59%, compared with 93% and 35% for IVC inspiratory collapse and 73% and 43% for the WHO scale. Ultrasound of the aorta/IVC ratio can be used to identify severe dehydration in children presenting with acute diarrhea and may be helpful in guiding clinical management. © 2010 by the Society for Academic Emergency Medicine.
Gargano, Julia W; Wilkinson, Edward J; Unger, Elizabeth R; Steinau, Martin; Watson, Meg; Huang, Youjie; Copeland, Glenn; Cozen, Wendy; Goodman, Marc T; Hopenhayn, Claudia; Lynch, Charles F; Hernandez, Brenda Y; Peters, Edward S; Saber, Maria Sibug; Lyu, Christopher W; Sands, Lauren A; Saraiya, Mona
2012-10-01
The study aimed to determine the baseline prevalence of human papillomavirus (HPV) types in invasive vulvar cancer (IVC) and vulvar intraepithelial neoplasia 3 (VIN 3) cases using data from 7 US cancer registries. Registries identified eligible cases diagnosed in 1994 to 2005 and requested pathology laboratories to prepare 1 representative block for HPV testing on those selected. Hematoxylin-eosin-stained sections preceding and following those used for extraction were reviewed to confirm representation. Human papillomavirus was detected using L1 consensus polymerase chain reaction (PCR) with PGMY9/11 primers and type-specific hybridization, with retesting of samples with negative and inadequate results with SPF10 primers. For IVC, the confirmatory hematoxylin-eosin slides were re-evaluated to determine histological type. Descriptive analyses were performed to examine distributions of HPV by histology and other factors. Human papillomavirus was detected in 121/176 (68.8%) cases of IVC and 66/68 (97.1%) cases of VIN 3 (p < .0001). Patients with IVC and VIN 3 differed by median age (70 vs 55 y, p = .003). Human papillomavirus 16 was present in 48.6% of IVC cases and 80.9% of VIN 3 cases; other high-risk HPV was present in 19.2% of IVC cases and 13.2% of VIN 3 cases. Prevalence of HPV differed by squamous cell carcinoma histological subtype (p < .0001) as follows: keratinizing, 49.1% (n = 55); nonkeratinizing, 85.7% (n = 14), basaloid, 92.3% (n = 14), warty 78.2% (n = 55), and mixed warty/basaloid, 100% (n = 7). Nearly all cases of VIN 3 and two thirds of IVC cases were positive for high-risk HPV. Prevalence of HPV ranged from 49.1% to 100% across squamous cell carcinoma histological subtypes. Given the high prevalence of HPV in IVC and VIN 3 cases, prophylactic vaccines have the potential to decrease the incidence of vulvar neoplasia.
Optical add/drop filter for wavelength division multiplexed systems
Deri, Robert J.; Strand, Oliver T.; Garrett, Henry E.
2002-01-01
An optical add/drop filter for wavelength division multiplexed systems and construction methods are disclosed. The add/drop filter includes a first ferrule having a first pre-formed opening for receiving a first optical fiber; an interference filter oriented to pass a first set of wavelengths along the first optical fiber and reflect a second set of wavelengths; and, a second ferrule having a second pre-formed opening for receiving the second optical fiber, and the reflected second set of wavelengths. A method for constructing the optical add/drop filter consists of the steps of forming a first set of openings in a first ferrule; inserting a first set of optical fibers into the first set of openings; forming a first set of guide pin openings in the first ferrule; dividing the first ferrule into a first ferrule portion and a second ferrule portion; forming an interference filter on the first ferrule portion; inserting guide pins through the first set of guide pin openings in the first ferrule portion and second ferrule portion to passively align the first set of optical fibers; removing material such that light reflected from the interference filter from the first set of optical fibers is accessible; forming a second set of openings in a second ferrule; inserting a second set of optical fibers into the second set of openings; and positioning the second ferrule with respect to the first ferrule such that the second set of optical fibers receive the light reflected from the interference filter.
Saddik, George N; York, Robert A
2012-09-01
This paper reports on the modeling, fabrication, and experimental results of a voltage switchable barium strontium titanate solidly mounted resonator filter at 6 GHz. The filter insertion loss was measured to be -4.26 dB and the return loss to be -13.5 dB. The 3-dB bandwidth was measured to be 72 MHz and the quality factor was calculated to be 83. The data were collected at a dc bias voltage of 10 V. Temperature data were also collected, and the filter demonstrated a 0.71-dB increase in insertion loss and a 7-MHz decrease in center frequency with increase in temperature.
Huang, Steven Y; Odisio, Bruno C; Sabir, Sharjeel H; Ensor, Joe E; Niekamp, Andrew S; Huynh, Tam T; Kroll, Michael; Gupta, Sanjay
2017-07-01
Our purpose was to develop a predictive model for short-term survival (i.e. <6 months) following inferior vena cava filter placement in patients with venous thromboembolism (VTE) and solid malignancy. Clinical and laboratory parameters were retrospectively reviewed for patients with solid malignancy who received a filter between January 2009 and December 2011 at a tertiary care cancer center. Multivariate Cox proportional hazards modeling was used to assess variables associated with 6 month survival following filter placement in patients with VTE and solid malignancy. Significant variables were used to generate a predictive model. 397 patients with solid malignancy received a filter during the study period. Three variables were associated with 6 month survival: (1) serum albumin [hazard ratio (HR) 0.496, P < 0.0001], (2) recent or planned surgery (<30 days) (HR 0.409, P < 0.0001), (3) TNM staging (stage 1 or 2 vs. stage 4, HR 0.177, P = 0.0001; stage 3 vs. stage 4, HR 0.367, P = 0.0002). These variables were used to develop a predictive model to estimate 6 month survival with an area under the receiver operating characteristic curve of 0.815, sensitivity of 0.782, and specificity of 0.715. Six month survival in patients with VTE and solid malignancy requiring filter placement can be predicted from three patient variables. Our predictive model could be used to help physicians decide whether a permanent or retrievable filter may be more appropriate as well as to assess the risks and benefits for filter retrieval within the context of survival longevity in patients with cancer.
Biswas, Saptarshi; Amin, Arpit; Chaudry, Suhaib; Joseph, Saju
2013-01-01
Leiomyosarcomas of the inferior Vena Cava (IVC) are rare soft tissue sarcomas accounting for only 0.5% of all soft tissue sarcomas in adults with fewer than 300 cases reported. Extraluminal tumor growth along the adventitia of the IVC seems to be the common presentation. Intraluminal tumor growth is rare. The origin of the tumor is divided into three levels in relation to the hepatic and renal veins. The presentations and surgical modalities vary accordingly. Retroperitoneal tumors are often not diagnosed until the disease is at an advanced stage with large tumor growth and involvement of surrounding structures. This is partly because of the nonspecific clinical presentation as well as absence of early symptoms. Most patients present with abdominal or flank pain. Symptoms vary according to the dimensions of the tumor, growth pattern and localization of the tumor. Radical en bloc resection of the affected venous segment remains the only therapeutic option associated with prolonged survival. The goals of surgical management of these tumors include the achievement of local tumor control, maintenance of caval flow, and the prevention of recurrence. The involvement of renal or hepatic veins determines the strategy for vascular reconstruction. Reconstruction of the IVC is not always required, because gradual occlusion of the IVC allows the development of venous collaterals. However, when pararenal leiomyosarcoma of the IVC is present, reconstruction of the IVC and the renal vein is necessary to prevent transient or permanent renal dysfunction. Recent study has shown that radical surgery combined with adjuvant multimodal therapy has improved the cumulative survival rate. We report a case of IVC leiomyosarcoma in a young healthy woman along with details of its diagnostic workup and discussion of the surgical options and reconstruction of caval continuity. PMID:29147340
Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B
2018-05-01
Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.
Phase II Randomized Trial of the Combination of Cetuximab and Sorafenib or Single Agent Cetuximab
2017-12-28
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary
2018-05-22
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Oral Cavity Squamous Cell Carcinoma; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary
2017-05-22
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
Hanneman, Kate; Thavendiranathan, Paaladinesh; Nguyen, Elsie T; Moshonov, Hadas; Wald, Rachel; Connelly, Kim A; Paul, Narinder S; Wintersperger, Bernd J; Crean, Andrew M
2015-08-01
To evaluate the value of cardiac magnetic resonance imaging (MRI)-based measurements of inferior vena cava (IVC) cross-sectional area in the diagnosis of pericardial constriction. Patients who had undergone cardiac MRI for evaluation of clinically suspected pericardial constriction were identified retrospectively. The diagnosis of pericardial constriction was established by clinical history, echocardiography, cardiac catheterization, intraoperative findings, and/or histopathology. Cross-sectional areas of the suprahepatic IVC and descending aorta were measured on a single axial steady-state free-precession (SSFP) image at the level of the esophageal hiatus in end-systole. Logistic regression and receiver-operating curve (ROC) analyses were performed. Thirty-six patients were included; 50% (n = 18) had pericardial constriction. Mean age was 53.9 ± 15.3 years, and 72% (n = 26) were male. IVC area, ratio of IVC to aortic area, pericardial thickness, and presence of respirophasic septal shift were all significantly different between patients with constriction and those without (P < .001 for all). IVC to aortic area ratio had the highest odds ratio for the prediction of constriction (1070, 95% confidence interval [8.0-143051], P = .005). ROC analysis illustrated that IVC to aortic area ratio discriminated between those with and without constriction with an area under the curve of 0.96 (95% confidence interval [0.91-1.00]). In patients referred for cardiac MRI assessment of suspected pericardial constriction, measurement of suprahepatic IVC cross-sectional area may be useful in confirming the diagnosis of constriction when used in combination with other imaging findings, including pericardial thickness and respirophasic septal shift. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Wang, Tracy S; Kline, Greg; Yen, Tina W; Yin, Ziyan; Liu, Ying; Rilling, William; So, Benny; Findling, James W; Evans, Douglas B; Pasieka, Janice L
2018-02-01
In patients with primary aldosteronism (PA), adrenal venous sampling (AVS) is recommended to differentiate between unilateral (UNI) or bilateral (BIL) adrenal disease. A recent study suggested that lateralization could be predicted, based on the ratio of aldosterone/cortisol levels (A/C) between the left adrenal vein (LAV) and inferior vena cava (IVC), with a 100% positive predictive value (PPV). This study aimed to validate those findings utilizing a larger, multi-institutional cohort. A retrospective review was performed of patients with PA who underwent AVS from 2 tertiary-care institutions. Laterality was predicted by an A/C ratio of >3:1 between the dominant and non-dominant adrenal. AVS results were compared to LAV/IVC ratios utilizing the published criteria (Lt ≥ 5.5; Rt ≤ 0.5). Of 222 patients, 124 (57%) had UNI and 98 (43%) had BIL disease based on AVS. AVS and LAV/IVC findings were concordant for laterality in 141 (64%) patients (69 UNI, 72 BIL). Using only the LAV/IVC ratio, 54 (24%) patients with UNI disease on AVS who underwent successful surgery would have been assumed to have BAH unless AVS was repeated, and 24 (11%) patients with BIL disease on AVS may have been incorrectly offered surgery (PPV 70%). Based on median LAV/IVC ratios (left 5.26; right 0.31; BIL 2.84), no LAV/IVC ratio accurately predicted laterality. This multi-institutional study of patients with both UNI and BIL PA failed to validate the previously reported PPV of LAV/IVC ratio for lateralization. Caution should be used in interpreting incomplete AVS data to differentiate between UNI versus BIL disease and strong consideration given to repeat AVS prior to adrenalectomy.
Kline, G A; Pasieka, J L; Harvey, A; So, B; Dias, V C
2014-05-01
We hypothesized aldosteronoma responsiveness to cosyntropin may be a characterizing feature that could be determined in addition to standard adrenal vein sampling (AVS) data. We reviewed an AVS database from June 2005 to October 2011 including 65 patients with confirmed primary aldosteronism (PA) who underwent AVS and, if applicable, unilateral adrenalectomy. Patients were divided into confirmed lateralized and non-lateralized groups and subgrouped by histology. Plasma aldosterone in inferior vena cava (IVC) pre- and post-cosyntropin infusion during AVS was measured. Peak aldosterone and proportional change was compared between groups. Baseline and peak IVC aldosterone was higher in lateralized patients but incremental aldosterone rise was much greater in subjects with bilateral hyperplasia. From receiver operator characteristics (ROC) analysis, the optimized diagnostic cut point of peak IVC aldosterone of >649 pmol l(-1) would have a sensitivity of 94% for surgical disease although specificity of just 59%. A 250% increase in IVC aldosterone following cosyntropin would be specific enough to exclude 87% of surgical/lateralized disease. These diagnostic capabilities are similar to other results with non-AVS tests performed for diagnosis of lateralization. Although not specific enough to replace standard AVS interpretation, a marked IVC aldosterone increase after cosyntropin during AVS is a useful additional test to diagnose non-lateralizing forms of PA. Such a calculation requires no additional expense or tests.
NASA Astrophysics Data System (ADS)
Kövér, László
2014-10-01
This Special Issue of the journal Applied Surface Science contains full papers from a selection of contributions presented in the Applied Surface Science sessions of the 19th International Vacuum Congress (IVC-19) held in the Palais des Congrès, Paris, between September 9 and 13, 2013. The triennial IVC conferences represent major meetings in the field of the vacuum related sciences and are the largest scientific events of the International Union for Vacuum Science, Technique and Applications (IUVSTA). The IVC-19 and partner conferences had altogether 2555 participants. Supported by the Applied Surface Science Division of IUVSTA, the Applied Surface Science part was one of the most attended among the sub-conferences of the IVC-19. This Special Issue - without trying to achieve completeness - intends to provide a cross section of the topics of the Applied Surface Science and joint sessions of the IVC-19, covering important fields such as Surface Analysis, Surface Modifications, Surface Chemistry and Catalysis, Quantitative Surface and Interface Analysis, Coatings, Tribology, Adhesion, Characterization of Nanomaterials, Energy and Sustainable Development, Self Assembly, Nano-instrumentation, SPM and Novel Probe Techniques, New Approaches and Novel Applications of Surface/Interface Analytical Methods.
Feng, Chao-Hui; Drummond, Liana; Zhang, Zhi-Hang; Sun, Da-Wen
2013-10-01
The effects of agitation (1002 rpm), different pressure reduction rates (60 and 100 mbar/min), as well as employing cold water with different initial temperatures (IWT: 7 and 20°C) on immersion vacuum cooling (IVC) of cooked pork hams were experimentally investigated. Final pork ham core temperature, cooling time, cooling loss, texture properties, colour and chemical composition were evaluated. The application for the first time of agitation during IVC substantially reduced the cooling time (47.39%) to 4.6°C, compared to IVC without agitation. For the different pressure drop rates, there was a trend that shorter IVC cooling times were achieved with lower cooling rate, although results were not statistically significant (P>0.05). For both IWTs tested, the same trend was observed: shorter cooling time and lower cooling loss were obtained under lower linear pressure drop rate of 60 mbar/min (not statistically significant, P>0.05). Compared to the reference cooling method (air blast cooling), IVC achieved higher cooling rates and better meat quality. Copyright © 2013 Elsevier Ltd. All rights reserved.
Recirculating electric air filter
Bergman, Werner
1986-01-01
An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.
Recirculating electric air filter
Bergman, W.
1985-01-09
An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.
Köcher, Martin; Krcova, Vera; Cerna, Marie; Prochazka, Martin
2009-04-01
To evaluate the feasibility and efficacy of the retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep vein thrombosis in the perinatal period and to discuss the technical demands associated with the filter's implantation and retrieval. Between 1996 until 2007, eight women (mean age 27.4 years, range 20-42 years) with acute deep iliofemoral venous thrombosis in the perinatal period of pregnancy and increased risk of pulmonary embolism during delivery were indicated for retrievable Günther Tulip Vena Cava Filter implantation. All filters were inserted and removed under local anesthesia from the jugular approach. The Günther Tulip Vena Cava Filter was implanted suprarenally in all patients on the day of caesarean delivery. In follow-up cavograms performed just before planned filter removal, no embolus was seen in the filter in any patient. In all patients the filter was retrieved without complications on the 12th day after implantation. Retrievable Günther Tulip Vena Cava Filters can be inserted and removed in patients during the perinatal period without major complications.
NASA Technical Reports Server (NTRS)
Subramanyam, Guru; VanKeuls, Fred W.; Miranda, Felix A.; Canedy, Chadwick L.; Aggarwal, Sanjeev; Venkatesan, Thirumalai; Ramesh, Ramamoorthy
2000-01-01
The correlation of electric field and critical design parameters such as the insertion loss, frequency ability return loss, and bandwidth of conductor/ferroelectric/dielectric microstrip tunable K-band microwave filters is discussed in this work. This work is based primarily on barium strontium titanate (BSTO) ferroelectric thin film based tunable microstrip filters for room temperature applications. Two new parameters which we believe will simplify the evaluation of ferroelectric thin films for tunable microwave filters, are defined. The first of these, called the sensitivity parameter, is defined as the incremental change in center frequency with incremental change in maximum applied electric field (EPEAK) in the filter. The other, the loss parameter, is defined as the incremental or decremental change in insertion loss of the filter with incremental change in maximum applied electric field. At room temperature, the Au/BSTO/LAO microstrip filters exhibited a sensitivity parameter value between 15 and 5 MHz/cm/kV. The loss parameter varied for different bias configurations used for electrically tuning the filter. The loss parameter varied from 0.05 to 0.01 dB/cm/kV at room temperature.
Identifying diversion of inferior vena cava after repair of atrial septal defect.
Lee, Yi Wei; Lee, Wei Chieh; Chua, Sarah
2015-10-01
Inadvertent IVC diversion into left atrium is a rare morbidity following ASD repair. Reported risk factors included a large secundum, or low-lying ASD, or inferior sinus venosus defect, and anomalous pulmonary connection into the RA. In our case, transesophageal echocardiogram showed abnormal connection of IVC to LA, but could not be identified owing to limited window. Cardiac CT could offer better anatomic clarification. On contrast transesophageal echocardiogram with agitated saline injected via right femoral vein, an abnormal right-to-left shunt was demonstrated by transit of microbubbles from IVC into LA, while majority of rest entered into the RA. Therefore, we confirm the IVC diversion into LA. Detection of such unusual condition is a challenge due to the fact that special echocardiographic windows are often needed.
1988-01-01
were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV
NASA Astrophysics Data System (ADS)
Jie, Cui; Lei, Chen; Peng, Zhao; Xu, Niu; Yi, Liu
2014-06-01
A broadband monolithic linear single pole, eight throw (SP8T) switch has been fabricated in 180 nm thin film silicon-on-insulator (SOI) CMOS technology with a quad-band GSM harmonic filter in integrated passive devices (IPD) technology, which is developed for cellular applications. The antenna switch module (ASM) features 1.2 dB insertion loss with filter on 2G bands and 0.4 dB insertion loss in 3G bands, less than -45 dB isolation and maximum -103 dB intermodulation distortion for mobile front ends by applying distributed architecture and adaptive supply voltage generator.
Helfand, Brian T; Smith, Norm D; Kozlowski, James M; Eskandari, Mark K
2011-01-01
Inferior vena cava (IVC) reconstruction for locally advanced renal cell carcinoma (RCC) includes resection with and without interposition grafting, patch graft, or primary repair. The proposed benefits of lateral venorrhaphy and primary repair are avoidance of foreign material, a more expeditious repair, and preservation of lower extremity venous outflow. A single-center retrospective review of 22 patients with RCC and IVC tumor thrombus treated with radical nephrectomy, lateral venorrhaphy, thrombectomy, and primary vena cava repair between July 2002 and June 2009 was carried out. Demographic data, diagnostic information, radiographic cross-sectional imaging, and procedural outcomes were examined. Among the 13 men and nine women, the mean age was 62.1 years (42-83); mean tumor size was 9.8 cm (3-17 cm), and 90% (n = 18) of the cases with RCC were identified pathologically as clear cell adenocarcinoma; on the basis of the classification system adopted by Neves, level I was for 50% (n = 11), level II for 32% (n = 7), level III for 9% (n = 2), and level IV for 9% (n = 2) of the patients. All patients underwent en bloc radical nephrectomy with tumor thrombus removal and primary IVC repair. Mean total operative time was 547.9 ± 138.5 minutes, whereas mean IVC cross-clamp time was 10.8 minutes (6-29 minutes). There were no intraoperative deaths or pulmonary embolism and all IVC margins were found to be pathologically negative. Postoperative complications included one pulmonary embolism, one exacerbation of chronic lymphedema, and two cases of new onset erectile dysfunction. Mean follow-up was 36.4 ± 23.2 months (6-92 months). There were no radiographic or clinically significant changes in mean IVC diameter during follow-up. Five late deaths (23%) occurred as a result of metastatic RCC over a mean period of 24 months (range, 12-48), but without any local recurrences. For advanced RCC with tumor thrombus extension into the IVC, lateral venorrhaphy and primary IVC repair avoids complicated caval reconstructions and results in high patency rates with a low local tumor recurrence rate. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel, E-mail: danielthomascookson@yahoo.co.uk; Caldwell, Stuart, E-mail: stuart.caldwell@middlemore.co.nz
Phlegmasia caerulea dolens (PCD) is a potentially disastrous complication of inferior vena cava filter insertion, and its optimum management has not been clearly established. We present a case report of a patient with pulmonary embolism and acute adrenal haemorrhage who developed PCD secondary to massive iliocaval thrombosis after insertion of a Cook Celect removable filter. Local intravenous catheter-directed thrombolysis (CDT), followed by systemic anticoagulation, achieved limb salvage and virtual resolution of symptoms at 3 months without complications. CDT can be a successful primary treatment of filter-associated PCD and can be safe in selected patients with acute nontraumatic haemorrhage. Systemic anticoagulationmore » may subsequently restore complete venous patency and may therefore be a useful approach to postthrombolysis management of residual iliocaval thrombus when filter removal is indicated.« less
Wavelength-tunable thulium-doped fiber laser by employing a self-made Fabry-Perot filter
NASA Astrophysics Data System (ADS)
Wang, Y. P.; Ju, Y. L.; Wu, C. T.; Liu, W.; Yang, C.
2017-06-01
In this demonstration, we proposed a novel wavelength-tunable thulium-doped fiber laser (TDFL) with a self-made Fabry-Perot (F-P) filter. When the F-P filter was not inserted, the maximum output power of 11.1 W was achieved when the pump power was 70.2 W. The corresponding optical-to-optical conversion efficiency was 15.8% and the slope efficiency was 22.1%. When the F-P filter was inserted, the output wavelength could be tuned from 1952.9 to 1934.9 nm with the change of cavity length of F-P filter which was fixed on a piezoelectric ceramic transducer (PZT) controlled by the voltage applied to it. The full width at half maximum (FWHM) was no more than 0.19 nm. Furthermore, the wavelength fluctuations of the tunable fiber laser were kept within ±0.2 nm.
NASA Technical Reports Server (NTRS)
Delaplaine, R. W.; Greenleaf, J. E.
1979-01-01
Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.
Rugged fiber optic probe for raman measurement
O'Rourke, Patrick E.; Toole, Jr., William R.; Nave, Stanley E.
1998-01-01
An optical probe for conducting light scattering analysis is disclosed. The probe comprises a hollow housing and a probe tip. A fiber assembly made up of a transmitting fiber and a receiving bundle is inserted in the tip. A filter assembly is inserted in the housing and connected to the fiber assembly. A signal line from the light source and to the spectrometer also is connected to the filter assembly and communicates with the fiber assembly. By using a spring-loaded assembly to hold the fiber connectors together with the in-line filters, complex and sensitive alignment procedures are avoided. The close proximity of the filter assembly to the probe tip eliminates or minimizes self-scattering generated by the optical fiber. Also, because the probe can contact the sample directly, sensitive optics can be eliminated.
Pheochromocytoma with inferior vena cava thrombosis: An unusual association.
Kota, Sunil K; Kota, Siva K; Jammula, Sruti; Meher, Lalit K; Modi, Kirtikumar D
2012-04-01
Pheochromocytomas have been described in association with vascular abnormalities like renal artery stenosis. A 48-year-old man was admitted to our hospital with the complaints of headache, sweating, anxiety, dizziness, nausea, vomiting and hypertension. For last several days, he was having a dull aching abdominal pain. Abdominal computed tomography (CT) revealed the presence of a left adrenal pheochromocytoma. An inferior vena cava (IVC) venogram via the right jugular vein demonstrated occlusion of the IVC inferior to the right atrium. Surgical removal of pheochromocytoma was done, followed by anticoagulant treatment for IVC thrombosis, initially with subcutaneous low molecular weight heparin, and then with oral warfarin, resulting in restoration of patency. To the best of our knowledge, the occurrence of pheochromocytoma in IVC thrombosis has not been reported so far from India. Possible mechanisms of such an involvement are discussed.
Eldeen, F Z; Lee, C-F; Lee, C-S; Chan, K-M; Lee, W-C
2013-03-01
The modified piggyback technique with side-to-side cavocavostomy decreases the risk of outflow obstruction compared with the standard piggyback method. However, this modification is not ideal for recipients who receive a graft that is voluminous or bears an enlarged caudate lobe. We modified the inferior vena cava (IVC) preservation technique against deleterious complications of compression by using a passing loop. A 49-year-old woman, who underwent orthotopic liver transplantation for hepatic failure, was allocated a large-size liver. In anticipation of serious caval compression due to the voluminous grafts, we kept the suprahepatic or infrahepatic donor caval cuffs open for an anastomosis. The first anastomosis was performed between suprahepatic donor IVC cuff and recipient middle-left hepatic vein common channel; the second anastomosis was a terminolateral cavocavostomy between infrahepatic donor IVC cuff and the anterior wall of the recipient's IVC. When the liver circulation was restored, the donor retrohepatic vena cava served as a passing loop for both hepatic venous outflow and infra-diaphragmatic venous return to bypass possible IVC compression. Our technique may solve a dilemna for patients receiving voluminous liver grafts. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.
Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.
21 CFR 347.52 - Labeling of astringent drug products.
Code of Federal Regulations, 2011 CFR
2011-04-01
... states “[bullet] dissolve 1 to 3 packets in [insert volume] of cool or warm water [bullet] stir until... [bullet] stir until fully dissolved; do not strain or filter. The resulting mixture contains [insert...
Fabiani, Massimo; Di Napoli, Anteo; Riccardo, Flavia; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio
2017-01-01
to evaluate differences in influenza vaccination coverage (IVC) in immigrants at risk for influenza-related complications, according to their area of origin and length of stay in Italy. cross-sectional survey conducted on the sample of foreign citizens included in the survey on health conditions and use of health services of the Italian resident population (Italian national institute of statistics, 2012-2013). analysis conducted on 885 foreign adult citizens (≥18 years) at risk for influenza-related complications (elderly residents ≥65 years and residents with specific chronic diseases). vaccination coverage ratios (VCR) comparison between long-term immigrants (≥10 years) and recent immigrants (<10 years), and between non-African and African immigrants, adjusted by demographic and socioeconomic characteristics and level of health services utilization. IVC among immigrants was 15.6%, significantly higher in long-term immigrants (18.3%) compared to recent immigrants (10.2%) (VCR: 1.79; 95%CI 1.21-2.66), and in non-African immigrants (17.1%) compared to African immigrants (9.4%) (VCR: 1.82; 95%CI 1.04-3.17). After adjusting on the basis of demographic and socioeconomic characteristics and for level of health services utilization between the compared subgroups, the difference in IVC according to the length of stay was greatly reduced (VCR: 1.41; 95%CI 0.94- 2.10), while IVC difference reduction according to area of origin was less relevant (VCR: 1.66; 95%CI 0.95-2.91). demographic and socioeconomic characteristics and level of health services utilization explained part of the difference in IVC between the compared subgroups, particularly between long-term and recent immigrants. The difference in IVC between African immigrants and immigrants from other areas remained quite pronounced even after adjusting on the basis of these factors. This suggests that IVC, especially in African immigrants, is affected by other informal barriers, such as cultural and linguistic barriers, that need to be addressed when planning effective immunization access strategies.
Hoffer, L. John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H.
2015-01-01
Background Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. Methods and Findings We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Conclusions Despite IVC’s biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC’s value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. Trial Registration ClinicalTrials.gov NCT01050621 PMID:25848948
2018-06-19
Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Major Salivary Gland Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary
Effect of Ventilated Caging on Water Intake and Loss in 4 Strains of Laboratory Mice
Nicolaus, Mackenzie L; Bergdall, Valerie K; Davis, Ian C; Hickman-Davis, Judy M
2016-01-01
Food availability, temperature, humidity, strain, and caging type all affect water consumption by mice. Measurement of transepidermal water loss (TEWL) is a new technique for the quantification of water turnover in mice. To understand water turnover in common strains of adult mice, male and female SCID, SKH, C57BL/6, and FVB mice were housed in same-sex groups of 5 animals in static cages or IVC. Body weight, TEWL, urine osmolality, and water consumption of mice and intracage temperature and humidity were measured every 48 h for comparison. Static cages were monitored for 7 d and IVC for 14 d before cage change. Female SCID, FVB, and C57 mice drank less water than did their male counterparts. Male and female SCID, SKH, and FVB mice in IVC drank less water and had higher urine osmolality than did those in static cages. In SCID and SKH mice, TEWL paralleled water consumption. C57 mice in static cages drank less water, had lower urine osmolality, and had less TEWL than did those in IVC. Temperature and humidity within the cage was higher than the macroenvironmental levels for all housing conditions, mouse strains, and sexes. Temperatures within IVC ranged from 76.6 to 81.4 °F compared with 69 ± 0.4 °F in the room. Humidity within IVC ranged from 68% to 79% compared with 27.o% ± 2.7% within the room. These data demonstrate that mouse strain and housing conditions significantly influence water balance and indicate that macroenvironmental measurements do not always reflect the intracage environment. PMID:27657706
Engineering Filters for Reducing Spontaneous Emission in cQED
NASA Astrophysics Data System (ADS)
Bronn, Nicholas; Masluk, Nicholas; Srinivasan, Srikanth; Chow, Jerry; Abraham, David; Rothwell, Mary; Keefe, George; Gambetta, Jay; Steffen, Matthias; Lirakis, Chris
2014-03-01
Inserting a notch filter between a qubit and the external environment at the qubit frequency can significantly suppress spontaneous emission mediated by the cavity (``Purcell effect''). In order to realize this filtering in multi-qubit architectures, where space comes at a premium, we will present a filter with minimal space requirements. We acknowledge support from IARPA under contract W911NF-10-1-0324.
Guon, Jerold
1976-04-13
A sintered filter trap is adapted for insertion in a gas stream of sodium vapor to condense and deposit sodium thereon. The filter is heated and operated above the melting temperature of sodium, resulting in a more efficient means to remove sodium particulates from the effluent inert gas emanating from the surface of a liquid sodium pool. Preferably the filter leaves are precoated with a natrophobic coating such as tetracosane.
Remotely serviced filter and housing
Ross, M.J.; Zaladonis, L.A.
1987-07-22
A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station. 6 figs.
Brar, Ranjeet; Skervin, Alicia; El-Sakka, Karim; Fish, Andrew; Lewis, Michael
2018-01-17
Intravenous extension of benign uterine leiomyomata ('fibroids'), in the absence of discrete metastatic disease has rarely been reported. 'Fibroids' remain one of the most common premenopausal uterine pathologies. We report the diagnosis and multidisciplinary led operative management of a 52-year-old woman with a histologically benign, but biologically aggressive, uterine leiomyoma with intravenous extension to the inferior vena cava (IVC), right heart and pulmonary arteries. Total abdominal hysterectomy and bilateral salpingo-oophorectomy combined with exploration of the sub-hepatic IVC and heart under deep hypothermic circulatory arrest achieved its successful macroscopic clearance.
Two cases of scimitar variant.
Takeda, S; Imachi, T; Arimitsu, K; Minami, M; Hayakawa, M
1994-01-01
The scimitar sign is characteristic of partial anomalous pulmonary venous drainage into the inferior vena cava (IVC). We encountered two variant cases of scimitar sign. In one case, the scimitar vein entered both the IVC and the left atrium (LA) without any intracardiac shunts. Surgical repair was made by simple ligation of the scimitar vein to correct the left to right shunt. Retrograde balloon occlusion angiography of the scimitar vein was diagnostic. In the other case, the scimitar vein showed a meandering course, and then drained into the LA without any connection with the IVC, and surgical intervention was not required.
Hagisawa, Kohsuke; Saito, Akihiro; Kinoshita, Manabu; Fujie, Toshinori; Otani, Naoki; Shono, Satoshi; Park, Young-Kwang; Takeoka, Shinji
2013-07-01
To investigate the efficacy of multioverlapping therapy using a polysaccharide nanosheet having 75-nm thickness for sealing and stopping massive venous hemorrhage. The hydrostatic durability of the polysaccharide nanosheet was evaluated in vitro when secured to an incised silicon tube. For in vivo studies, the inferior vena cava (IVC) of rabbits was cut longitudinally, and multiple polysaccharide nanosheets were overlapped onto the injured IVC. The mechanical hydrostatic durability of the nanosheets was gradually augmented by an increasing number of multilayered nanosheets in vitro. This durability was saturated at 80 ± 6 mm Hg by four layers of nanosheets, which was robust enough to seal injured vessel walls of the large IVC. Multioverlapping therapy using nanosheets effectively sealed and stopped bleeding from the injured IVC in vivo. One month later, no inflammatory tissue response was observed around the nanosheet attachment sites of the IVC, while conventional suturing repair in control rabbits showed a severe inflammatory response around the sutured area. The multioverlapping therapy using the polysaccharide nanosheets will effectively stop massive venous bleeding without adverse effects in the immediate or chronic postoperative setting. Copyright © 2013 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Congenital abnormalities of the inferior vena cava presenting clinically in adolescent males.
Halparin, Jessica; Monagle, Paul; Newall, Fiona
2015-04-01
Congenital anatomic abnormality of the inferior vena cava (IVC) is an important risk factor for the development of spontaneous proximal lower extremity deep vein thrombosis (DVT) in young adults. The incidence of DVT associated with congenital IVC anomalies in paediatric populations has not been described, and the implications of IVC anomalies for treatment and outcomes of DVT are unknown. This study reports a series of five adolescent males with spontaneous lower extremity DVTs and underlying congenital IVC abnormalities. Cases were identified by searching the institutional database of patients treated with anticoagulation for venous thromboembolism at a tertiary children's hospital. The demographics, clinical presentations, imaging findings, treatment courses, and outcomes are described. All cases occurred in males, and accounted for approximately twenty percent of adolescent males presenting with DVT. IVC abnormality is likely an under-recognized risk factor for DVT in this age group, and detailed vascular imaging should be pursued in adolescents with spontaneous proximal lower extremity DVT when initial ultrasonography does not delineate the proximal clot extent. Management requires individual risk-benefit assessment in the context of providing developmentally appropriate care. Further research is required to establish long-term outcomes and determine optimal treatment strategies. Copyright © 2015 Elsevier Ltd. All rights reserved.
Prospective surveillance of phlebitis associated with peripheral intravenous catheters.
Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David
2006-06-01
Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P < .01). Factors significantly associated with phlebitis included pain (P < .001), presence of the catheter for longer than 3 days (P < .05), and cleanliness of the dressing (P < .01). The rate of phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.
Ghanney, Efe C; Cavallo, Jaime A; Levin, Matthew A; Reddy, Ramachandra; Bander, Jeffrey; Mella, Maria; Stone, Joanne; Schwartz, Myron; Haines, Kenneth; Gidwani, Umesh; Mehrazin, Reza
2017-12-01
Only one case of renal cell carcinoma (RCC) with inferior vena cava (IVC) tumor thrombus diagnosed and treated during pregnancy has been reported in the literature. In that report, the tumor thrombus extended to the infrahepatic IVC (level II tumor thrombus). In the present case, a 37-year-old woman with lupus anticoagulant antibodies was diagnosed with RCC and IVC tumor thrombus extending to the right atrium (level IV tumor thrombus) at 24 weeks of pregnancy. The fetus was safely delivered by cesarean section at 30 weeks of gestation. At 4 days later, an open right radical nephrectomy and IVC and right atrial thrombectomy were performed on cardiopulmonary bypass (CPB) once the patient's hemodynamic status had been optimized. Fetal and maternal concerns included the risk of a thromboembolic event (due to increased hypercoagulability from pregnancy, active malignancy, and lupus anticoagulant), intraoperative hemorrhage risk (due to extensive venous collaterals and anticoagulation), and fetal morbidity and mortality (due to fetal lung immaturity). Standardized guidelines for treatment of RCC with or without IVC tumor thrombus during pregnancy are unavailable due to the infrequency of such cases. Treatment decisions are therefore individualized and this case report may inform the management of future patients diagnosed with RCC with level IV tumor thrombus during pregnancy.
Interlaminar and lateral excitatory amino acid connections in the striate cortex of monkey.
Kisvarday, Z F; Cowey, A; Smith, A D; Somogyi, P
1989-02-01
The intrinsic excitatory amino acid pathways within the striate cortex of monkeys were studied by autoradiographic detection of retrogradely labeled somata following microinjections of D-3H-aspartate (D-3H-Asp) into different layers. The labeled amino acid was selectively accumulated by subpopulations of neurons and, to a small extent, by glial cells, the latter mainly in the supragranular layers. Immunocytochemical detection of neurons containing GABA showed that, apart from a few cells exclusively in layer I, GABAergic neurons do not accumulate D-3H-Asp. Several lines of evidence suggest that D-3H-Asp uptake occurred only at nerve terminals; thus, the pattern of perikaryal labeling allowed the delineation of interlaminar and lateral projections. Neurons in layer I probably project laterally, and layer I receives wide-ranging projections from layer IVB and layer V from cells up to 1300 microns laterally. Some neurons in layer II send a focused projection to lower layer VI. Some neurons in layers II/III project up to 1 mm laterally within their own layer, but relatively few neurons can be labeled in these projections. Similarly, in layers II/III few neurons can be retrogradely labeled from layers V and upper VI, and this projection is organized such that cells closer to the pia project deeper in layer V/VI. The connections of layer IVA could not be revealed separately because of the difficulty of confining injections to this thin sublamina. Neurons in layer IVB project up to 1300 microns within IVB itself. A small number of cells from IVB also project to layers III, IVC-alpha, V, and VI with much more restricted lateral spread. Neurons in upper IVC-alpha send axons to layer IVB with at least 600-800 microns lateral spread. Neurons in lower IVC-alpha/upper IVC-beta project to layer III with at least 300-500 microns lateral spread. The bottom 50-80 microns of layer IVC-beta contains neurons with a very focused projection, apparently exclusively to the layer III/IVA border region. Both layers IVC alpha and beta have rich connections within themselves, the beta sublayer having more restricted lateral connections. Some neurons in layer IVC-beta give a laterally restricted small input to layers IVC-alpha and IVB. Both IVC-alpha and -beta project to layers V and VI, and these projections are spread at least 400 microns laterally. Neurons in layer V project to all layers, but the projection to layers I-III and within layer V itself spread much further laterally than the projections to layers IV and VI.(ABSTRACT TRUNCATED AT 400 WORDS)
Design and analysis of a high Q MEMS passive RF filter
NASA Astrophysics Data System (ADS)
Rathee, Vishal; Pande, Rajesh
2016-04-01
Over the past few years, significant growth has been observed in using MEMS based passive components in the RF microelectronics domain, especially in transceiver system. This is due to some excellent properties of the MEMS devices like low loss, low cost and excellent isolation. This paper presents a design of high performance MEMS passive band pass filter, consisting of L and C with improved quality factor and insertion loss less than the reported filters. In this paper we have presented a design of 2nd order band pass filter with 2.4GHz centre frequency and 83MHz bandwidth for Bluetooth application. The simulation results showed improved Q-factor of 34 and Insertion loss of 1.7dB to 1.9dB. The simulation results needs to be validated by fabricating the device, fabrication flow of which is also presented in the paper.
2014-08-20
Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer
Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Chowa, Erika P; Dvor, Nathan; Dworkis, Daniel A; Oh, Michael; Silvestri, David M; Strasberg, Stephen; Rege, Soham; Noble, Vicki E; Alam, Nur H; Levine, Adam C
2016-01-01
Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having "some dehydration" with weight change 3-9% or "severe dehydration" with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting.
Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Rege, Soham; Noble, Vicki E.; Alam, Nur H.; Levine, Adam C.
2016-01-01
Introduction Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. Objective To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. Methods A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having “some dehydration” with weight change 3–9% or “severe dehydration” with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. Results 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Conclusions Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting. PMID:26766306
Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.
Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro
2017-10-01
Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.
Remotely serviced filter and housing
Ross, Maurice J.; Zaladonis, Larry A.
1988-09-27
A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge using an overhead crane. The filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station.
Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru
2015-09-01
Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.
Optical Filter Assembly for Interplanetary Optical Communications
NASA Technical Reports Server (NTRS)
Chen, Yijiang; Hemmati, Hamid
2013-01-01
Ground-based, narrow-band, high throughput optical filters are required for optical links from deep space. We report on the development of a tunable filter assembly that operates at telecommunication window of 1550 nanometers. Low insertion loss of 0.5 decibels and bandwidth of 90 picometers over a 2000 nanometers operational range of detectors has been achieved.
Munier, Francis L; Mosimann, Pascal; Puccinelli, Francesco; Gaillard, Marie-Claire; Stathopoulos, Christina; Houghton, Susan; Bergin, Ciara; Beck-Popovic, Maja
2017-08-01
The introduction of intra-arterial chemotherapy (IAC) as salvage treatment has improved the prognosis for eye conservation in group D retinoblastoma. The aim of this study was to compare the outcomes of consecutive patients with advanced unilateral disease treated with either first-line intravenous chemotherapy (IVC) or first-line IAC. This is a retrospective mono-centric comparative review of consecutive patients. Sporadic unilateral retinoblastoma group D cases treated conservatively at Jules-Gonin Eye Hospital and CHUV between 1997 and 2014. From January 1997 to August 2008, IVC, combined with focal treatments, was the primary treatment approach. From September 2008 to October 2014, IAC replaced IVC as first-line therapy. 48 patients met the inclusion criteria, receiving only either IAC or IVC as primary treatment modality. Outcomes of 23 patients treated by IVC were compared with those of 25 treated by IAC; mean follow-up was 105.3 months (range 29.2-218.6) and 41.7 months (range 19.6-89.5), respectively. Treatment duration was significantly shorter in the IAC group (p<0.001). Ten eyes in the IVC group underwent enucleation. Recordable visual acuity of the salvaged eyes was significantly better in the IAC group (0.9 vs 1.4 logarithm of the minimum angle of resolution, p<0.01). No extraocular disease, metastases or long-term systemic complications were observed in either group. The difference in the time frame between treatment groups had an impact on the availability of intravitreal chemotherapy treatment. Despite this, the results reported here imply that eyes treated with first-line IAC will have shorter treatment period, better ocular survival and visual acuity than first-line IVC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
McElhinney, Doff B; Marx, Gerald R; Newburger, Jane W
2011-01-01
Published case reports suggest that congenital portosystemic venous connections (PSVC) and other abdominal venous anomalies may be relatively frequent and potentially important in patients with polysplenia syndrome. Our objective was to investigate the frequency and range of portal and other abdominal systemic venous anomalies in patients with polysplenia and inferior vena cava (IVC) interruption who underwent a cavopulmonary anastomosis procedure at our center, and to review the published literature on this topic and the potential clinical importance of such anomalies. Retrospective cohort study and literature review were used. Among 77 patients with heterotaxy, univentricular heart disease, and IVC interruption who underwent a bidirectional Glenn and/or modified Fontan procedure, pulmonary arteriovenous malformations were diagnosed in 33 (43%). Bilateral superior vena cavas were present in 42 patients (55%). Despite inadequate imaging in many patients, a partial PSVC, dual IVCs, and/or renal vein anomalies were detected in 15 patients (19%). A PSVC formed by a tortuous vessel running from the systemic venous system to the extrahepatic portal vein was found in six patients (8%). Abdominal venous anomalies other than PSVC were documented in 13 patients (16%), including nine (12%) with some form of duplicated IVC system, with a large azygous vein continuing to the superior vena cava and a parallel, contralateral IVC of similar or smaller size, and seven with renal vein anomalies. In patients with a partial PSVC or a duplicate IVC that connected to the atrium, the abnormal connection allowed right-to-left shunting. PSVC and other abdominal venous anomalies may be clinically important but under-recognized in patients with IVC interruption and univentricular heart disease. In such patients, preoperative evaluation of the abdominal systemic venous system may be valuable. More data are necessary to determine whether there is a pathophysiologic connection between the polysplenia variant of heterotaxy, PSVC, and cavopulmonary anastomosis-associated pulmonary arteriovenous malformations. © 2011 Copyright the Authors. Congenital Heart Disease © 2011 Wiley Periodicals, Inc.
Fabiani, Massimo; Riccardo, Flavia; Di Napoli, Anteo; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio
2016-01-01
Background Due to their increased vulnerability, immigrants are considered a priority group for communicable disease prevention and control in Europe. This study aims to compare influenza vaccination coverage (IVC) between regular immigrants and Italian citizens at risk for its complications and evaluate factors affecting differences. Methods Based on data collected by the National Institute of Statistics during a population-based cross-sectional survey conducted in Italy in 2012–2013, we analysed information on 42,048 adult residents (≥ 18 years) at risk for influenza-related complications and with free access to vaccination (elderly residents ≥ 65 years and residents with specific chronic diseases). We compared IVC between 885 regular immigrants and 41,163 Italian citizens using log-binomial models and stratifying immigrants by area of origin and length of stay in Italy (recent: < 10 years; long-term: ≥ 10 years). Results IVC among all immigrants was 16.9% compared to 40.2% among Italian citizens (vaccination coverage ratio (VCR) = 0.42, 95% confidence interval (CI): 0.36–0.49). Adjusting for sex, age and area of residence, this difference was greatly reduced but remained statistically significant (VCR = 0.71, 95 CI: 0.61–0.81). Further adjustment for socio-economic factors (education, occupation, family composition and economic status) and a composite indicator of health-services utilization did not affect the difference (VCR = 0.78, 95% CI: 0.68–0.90). However, after adjustments, only long-term immigrants from Africa (VCR = 0.49, 95% CI: 0.28–0.85) and recent immigrants (VCR = 0.58, 95% CI: 0.43–0.78) showed a significantly different IVC compared to Italian citizens. Conclusions Differences in demographic characteristics, socio-economic conditions and health-services utilization explained the reduced IVC in most long-term immigrants compared to Italian citizens. By contrast, these differences did not explain the reduced IVC in long-term immigrants from Africa and recent immigrants. This suggests that IVC in these sub-groups is affected by other informal barriers (e.g., cultural and linguistic) that need to be investigated to promote effective immunization access strategies. PMID:27832186
Cardiac transplantation in situs inversus: two cases reports.
Chang, Y L; Wei, J; Chang, C-Y; Chuang, Y-C; Sue, S-H
2008-10-01
The challenge of heart transplantation in patients with situs inversus is reconstruction of the systemic venous return. Herein we have presented 2 cases of complex congenital heart disease with atriovisceral situs inversus. Both of the patients shared many common cardiac anomalies, such as a single ventricle, a single AV valve with severe regurgitation, and severe pulmonary stenosis. We completed the venous connection in 2 different ways. In the first case, the donor inferior vena cava (IVC) was anastomosed to the recipient left-sided IVC directly, making the heart slightly counterclockwise rotated. In the second case, the IVC venous reconnection was accomplished by a composite conduit made of recipient right atrium.
2017-08-18
Recurrent Thyroid Gland Carcinoma; Stage III Thyroid Gland Follicular Carcinoma; Stage III Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Medullary Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Medullary Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Medullary Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma
Prognostic significance of dilated inferior vena cava in advanced decompensated heart failure.
Lee, Hsin-Fu; Hsu, Lung-An; Chang, Chi-Jen; Chan, Yi-Hsin; Wang, Chun-Li; Ho, Wan-Jing; Chu, Pao-Hsien
2014-10-01
Dilated inferior vena cava (IVC) is prevalent among patients with heart failure (HF), but whether its presence predicts worsening renal function (WRF) or adverse outcomes is unclear. This cohort study analyzed patients with left ventricular ejection fraction <40 % and repeated hospitalizations (≥2 times) for HF between August 2009 and August 2011. The study endpoints were death and HF re-hospitalization. Among baseline parameters, IVC diameter was the most powerful predictor for the development of WRF (area under the curve = 0.795, cut-off value = 20.5 mm). During the 2-year follow-up, 36 patients (49 %) were re-hospitalized for HF and 14 patients (19 %) died. The event rates were significantly greater in the WRF group than in the non-WRF group (71 vs. 30 %, P < 0.001 for HF re-hospitalization; 29 vs. 10 %, P = 0.03 for death). In Cox regression model, the risk of combined end-points was increased in patients with aging, elevated blood urine nitrogen, IVC >21 mm, and WRF. When adjusted for confounding factors, IVC >21 mm [hazard ratio (HR) 3.73, 95 % confidence interval (CI) 1.66-8.34] and WRF (HR 2.68, 95 % CI 1.07-6.75) were significant predictors for adverse outcomes. In patients with advanced decompensated HF, dilated IVC (>21 mm) predicted the development of WRF and could be a predictor for adverse outcomes.
Should we isolate human preantral follicles before or after cryopreservation of ovarian tissue?
Vanacker, Julie; Luyckx, Valérie; Amorim, Christiani; Dolmans, Marie-Madeleine; Van Langendonckt, Anne; Donnez, Jacques; Camboni, Alessandra
2013-04-01
To evaluate the survival and growth potential of human preantral follicles isolated before and after cryopreservation. Pilot study. Gynecology research unit in a university hospital. Six women aged 27 to 32 years. Six ovarian biopsy samples were cut into two equal parts, half subjected to slow-freezing followed by follicle isolation (cryo-iso group) and alginate-matrigel embedding, and half immediately processed for follicle isolation and alginate-matrigel embedding followed by slow-freezing (iso-cryo group) or used as fresh controls (fresh group). Follicle number, viability, diameter, and morphology. After 1,134 preantral follicles had been isolated from fresh biopsy samples and 1,132 from frozen specimens, the three groups were compared before and after 7 days of in vitro culture (IVC) in alginate-matrigel beads. No statistically significant differences in viability were found between the three groups before or after IVC, but follicle diameter increased in all three groups after IVC. Morphology analysis revealed well-preserved follicles in both the iso-cryo and cryo-iso groups after IVC. Human preantral follicles can be successfully cryopreserved before or after isolation without impairing their ability to survive and grow in vitro. This could lead to development of new protocols for follicle cryopreservation, IVC, and grafting in clinical and research settings for fertility preservation. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
2014-06-05
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary
Progress on applications of high temperature superconducting microwave filters
NASA Astrophysics Data System (ADS)
Chunguang, Li; Xu, Wang; Jia, Wang; Liang, Sun; Yusheng, He
2017-07-01
In the past two decades, various kinds of high performance high temperature superconducting (HTS) filters have been constructed and the HTS filters and their front-end subsystems have been successfully applied in many fields. The HTS filters with small insertion loss, narrow bandwidth, flat in-band group delay, deep out-of-band rejection, and steep skirt slope are reviewed. Novel HTS filter design technologies, including those in high power handling filters, multiband filters and frequency tunable filters, are reviewed, as well as the all-HTS integrated front-end receivers. The successful applications to various civilian fields, such as mobile communication, radar, deep space detection, and satellite technology, are also reviewed.
Qin, Peng; Song, Youjian; Kim, Hyoji; Shin, Junho; Kwon, Dohyeon; Hu, Minglie; Wang, Chingyue; Kim, Jungwon
2014-11-17
Fiber lasers mode-locked with normal cavity dispersion have recently attracted great attention due to large output pulse energy and femtosecond pulse duration. Here we accurately characterized the timing jitter of normal-dispersion fiber lasers using a balanced cross-correlation method. The timing jitter characterization experiments show that the timing jitter of normal-dispersion mode-locked fiber lasers can be significantly reduced by using narrow band-pass filtering (e.g., 7-nm bandwidth filtering in this work). We further identify that the timing jitter of the fiber laser is confined in a limited range, which is almost independent of cavity dispersion map due to the amplifier-similariton formation by insertion of the narrow bandpass filter. The lowest observed timing jitter reaches 0.57 fs (rms) integrated from 10 kHz to 10 MHz Fourier frequency. The rms relative intensity noise (RIN) is also reduced from 0.37% to 0.02% (integrated from 1 kHz to 5 MHz Fourier frequency) by the insertion of narrow band-pass filter.
Pazopanib Hydrochloride in Treating Patients With Advanced Thyroid Cancer
2018-05-08
Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVB Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVC Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Thyroglobulin Antibody Negative; Thyroid Gland Undifferentiated (Anaplastic) Carcinoma
Tasse, Jordan; Borge, Marc; Pierce, Kenneth; Brems, John
2011-01-01
To describe the safety and efficacy of percutaneous transluminal angioplasty and stent placement in patients presenting with suprahepatic inferior vena cava (IVC) outflow compromise in the early postoperative period following orthotopic liver transplantation. Between October 2002 and April 2009, 3 patients presented with IVC outflow compromise in the first 2 months following orthotopic liver transplantation. All 3 underwent percutaneous transluminal angioplasty and stent placement without complication and showed significant clinical improvement at short and intermediate term follow-up. Percutaneous transluminal angioplasty and Gianturco stent placement is a safe and effective treatment for IVC outflow compromise in the early postoperative period following orthotopic liver transplantation.
2015-11-04
Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer
ESEA Title IV-C Innovation Administration Manual for South Carolina.
ERIC Educational Resources Information Center
South Carolina State Dept. of Education, Columbia. Office of Federal Programs.
The intent of Title IV-C of the Elementary and Secondary Education Act (the Education Amendments of 1974) is to establish innovative and exemplary projects that provide creative or imaginative solutions to problems in the areas of supplementary centers and services, health and nutritional demonstrations, and dropout prevention. The purposes of…
NASA Astrophysics Data System (ADS)
Deutsch, A.; Langenhorst, F.; Berndt, J.
2015-09-01
We report for the four internally rather homogeneous groups of glass (IVC, IVC-MT, BOT 12 [suevite], FBG) concentrations of major and 42 minor elements (in-situ data with LA-ICP-MS) as well as Sr-Nd, and DEGAS data.
Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.
Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H
1996-03-01
The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.
Miniaturized LTCC elliptic-function lowpass filters with side stopbands
Hsieh, Lung -Hwa; Dai, Steve Xunhu
2015-05-28
A compact, high-selectivity, and wide stopband lowpass filter is highly demanded in wireless communication systems to suppress adjacent harmonics and unwanted signals. In this letter, a new miniaturized lowpass filter with elliptic-function frequency response is introduced. The filter is fabricated in multilayer low temperature cofired ceramics. The size of the miniaturized filter is 5.5 × 3.9 × 1.72 mm3. As a result, the measured insertion loss of the filter is better than 0.37 dB from DC to 1.28 GHz and the measured stopband of the filter is great than 22 dB from 2.3 to 7.5 GHz.
Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki
2013-07-01
Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.
Dyszkiewicz-Konwińska, M; Bryja, A; Jopek, K; Budna, J; Khozmi, R; Jeseta, M; Bukowska, D; Antosik, P; Bruska, M; Nowicki, M; Zabel, M; Kempisty, B
2017-01-01
Recently, using experimental animal model, we demonstrated that porcine buccal pouch mucosal cells reflect increased proliferation capability during primary cultivation in vitro. Although the histological structure and morphogenesis in oral cavity is well recognized, the molecular mechanisms which regulate this process still need further investigation. This study was aimed to analyze the molecular marker expression profile involved in morphogenesis and differentiation capacity of porcine buccal pouch mucosal cells during their long-term primary cultivation in vitro. The experiment was performed on buccal pouch mucosal cells isolated from 80 pubertal crossbred Landrace gilts. After collection, the cells were treated enzymatically and transferred into a primary in vitro culture (IVC) system and cultured for 30 days. The cells were collected for RNA isolation after 7, 15 and 30 days of IVC and were checked for their real-time proliferative status using the RTCA system. We found an increased expression of FN1 and SOX9 genes when calculated against ACTB after 7, and 30 days of IVC, (P less than 0.01, P less than 0.001, respectively). The CXCL12 mRNA was down-regulated after 7, 15 and 30 days of IVC, but not statistically significant. Similar expression profile was observed when calculated against HPRT, however, DAB2 was found to be higher expressed at day 15 of IVC, (P less than 0.05). The cell index measured during real-time cell proliferation was substantially increased between 96 h and 147h of IVC and reached the log phase. Since FN1 and SOX9 revealed significant increase of expression after long-term culture in vitro, it is suggested that expression of these differentiation and stemness genes is accompanied by cell proliferation. Moreover, FN1 and SOX9 might be recognized as new markers of buccal pouch mucosal cell proliferation and differentiation in pigs in in vitro primary culture model.
2013-12-10
Mucositis; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
Kang, Jieun; Kim, Seon Ok; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2018-05-17
Malignancy is associated with an increased risk of venous thromboembolism. Inferior vena cava filters are a viable alternative when anticoagulation is infeasible because of the risk of bleeding. Although the current guidelines recommend that all patients with a vena cava filter be treated with anticoagulation treatment when the risk of bleeding is reduced, studies concerning the role of concomitant anticoagulation after vena cava filter insertion in high-risk patients are scarce. Since many cancer patients suffer from a high risk of hemorrhagic complications, we aimed to determine the effect of post-filter anticoagulation on mortality in patients with a malignant solid tumor. A retrospective cohort study of patients with pulmonary embolism was performed between January 2010 and May 2016. Patients with a solid tumor and vena cava filter inserted because of pulmonary embolism were included. Using Cox proportional hazards model, the prognostic effect of clinical variables was analyzed. A total of 180 patients were analyzed, with 143 patients receiving and 37 patients not receiving post-filter anticoagulation treatment. Mortality was not significantly different between the two groups. The presence of metastatic cancer and that of pancreatobiliary cancer were significant risk factors for mortality. However, post-filter anticoagulation did not show significant effect on mortality regardless of the stage of cancer. In patients with cancer-associated pulmonary embolism, the effect of post-filter anticoagulation on mortality may not be critical, especially in patients with a short life expectancy.
Winter, Christian; Pfister, David; Busch, Jonas; Bingöl, Cigdem; Ranft, Ulrich; Schrader, Mark; Dieckmann, Klaus-Peter; Heidenreich, Axel; Albers, Peter
2012-02-01
Residual tumor resection (RTR) after chemotherapy in patients with advanced germ cell tumors (GCT) is an important part of the multimodal treatment. To provide a complete resection of residual tumor, additional surgical procedures are sometimes necessary. In particular, additional vascular interventions are high-risk procedures that require multidisciplinary planning and adequate resources to optimize outcome. The aim was to identify parameters that predict additional vascular procedures during RTR in GCT patients. A retrospective analysis was performed in 402 GCT patients who underwent 414 RTRs in 9 German Testicular Cancer Study Group (GTCSG) centers. Overall, 339 of 414 RTRs were evaluable with complete perioperative data sets. The RTR database was queried for additional vascular procedures (inferior vena cava [IVC] interventions, aortic prosthesis) and correlated to International Germ Cell Cancer Collaborative Group (IGCCCG) classification and residual tumor volume. In 40 RTRs, major vascular procedures (23 IVC resections with or without prosthesis, 11 partial IVC resections, and 6 aortic prostheses) were performed. In univariate analysis, the necessity of IVC intervention was significantly correlated with IGCCCG (14.1% intermediate/poor vs 4.8% good; p=0.0047) and residual tumor size (3.7% size < 5 cm vs 17.9% size ≥ 5 cm; p < 0.0001). In multivariate analysis, IVC intervention was significantly associated with residual tumor size ≥ 5 cm (odds ratio [OR]: 4.61; p=0.0007). In a predictive model combining residual tumor size and IGCCCG classification, every fifth patient (20.4%) with a residual tumor size ≥ 5 cm and intermediate or poor prognosis needed an IVC intervention during RTR. The need for an aortic prosthesis showed no correlation to either IGCCCG (p=0.1811) or tumor size (p=0.0651). The necessity for IVC intervention during RTR is correlated to residual tumor size and initial IGCCCG classification. Patients with high-volume residual tumors and intermediate or poor risk features must initially be identified as high-risk patients for vascular procedures and therefore should be referred to specialized surgical centers with the ad hoc possibility of vascular interventions. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.
2016-07-30
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
Ciesiółka, S; Budna, J; Bryja, A; Kranc, W; Chachuła, A; Dyszkiewicz-Konwińska, M; Piotrowska, H; Bukowska, D; Antosik, P; Bruska, M; Brüssow, K P; Nowicki, M; Zabel, M; Kempisty, B
2016-01-01
Folliculogenesis is a compound process that involves both ovarian follicle growth and oocyte development, which is tightly attached to the follicular wall. During this process, cells that form the follicle structure undergo substantial morphological and molecular modifications that finally lead to differentiation and specialization of ovarian follicular cells. The differentiation of ovarian cells encompasses formation of follicle, which is composed of theca (TCs), mural granulosa (GCs), and cumulus cells (CCs). It was previously hypothesized that GCs and CCs represent undifferentiated and highly specialized follicular cells, respectively, which may have similar primordial cell origins. In this study, we investigated the expression pattern of cumulus expansion markers such as COX2, HAS2, PTX3, and TSG6 in porcine GCs during short-term, in vitro culture. We hypothesized that these genes may display an important function in GCs in relation to cellular real-time proliferation. The expression pattern of COX2, HAS2, PTX3, and TSG6 was evaluated after using RT-qPCR in relation to confocal microscopy observations of protein expression and distribution during real-time proliferation of porcine follicular GCs. The COX2 and HAS2 mRNAs were highly expressed after 120 h of in vitro culture (IVC), whereas PTX3 and TSG6 mRNAs were increased during the first 24-48 h of IVC (P less than 0.001, P less than 0.01). Conversely, all of the encoded proteins were highly expressed after 144-168 h of IVC as compared to other culture periods (P less than 0.001, P less than 0.01). When analyzing the realtime proliferation of GCs in vitro, we observed a logarithmic increase of cell proliferation between 0 h and 120 h of IVC. However, after 120-168 h of IVC, the cells reached the lag phase of proliferation. Since it is well accepted that porcine GCs undergo luteinization shortly after 24-48 h of IVC, the expression pattern of investigated genes indicated that Cox2 and Has2 are independent from the LH surge, but their increased levels may be upregulated by cell proliferation in vitro. Moreover, higher expression of PTX3 and TSG6 during first 24 h and/or 48 h of IVC suggested that their levels are accompanied by porcine GCs luteinization process.
2018-05-23
Recurrent Colon Carcinoma; Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Rectal Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Colon Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Rectal Cancer AJCC v7; Stage IVB Colon Cancer AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Rectal Cancer AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary
YBCO High-Temperature Superconducting Filters on M-Plane Sapphire Substrates
NASA Technical Reports Server (NTRS)
Sabataitis, J. C.; Mueller, C. H.; Miranda, F. A.; Warner, J.; Bhasin, K. B.
1996-01-01
Since the discovery of High Temperature Superconductors (HTS) in 1986, microwave circuits have been demonstrated using HTS films on various substrates. These HTS-based circuits have proven to operate with less power loss than their metallic film counterparts at 77 K. This translates into smaller and lighter microwave circuits for space communication systems such as multiplexer filter banks. High quality HTS films have conventionally been deposited on lanthanum aluminate (LaAlO3) substrates. However, LaAlO3 has a relative dielectric constant (epsilon(sub r)) of 24. With a epsilon(sub r) approx. 9.4-11.6, sapphire (Al2O3) would be a preferable substrate for the fabrication of HTS-based components since the lower dielectric constant would permit wider microstrip lines to be used in filter design, since the lower dielectric constant would permit wider microstrip lines to be used for a given characteristic impedance (Z(sub 0)), thus lowering the insertion losses and increasing the power handling capabilities of the devices. We report on the fabrication and characterization of YBa2Cu3O(7-delta) (YBCO) on M-plane sapphire bandpass filters at 4.0 GHz. For a YBCO 'hairpin' filter, a minimum insertion loss of 0.5 dB was measured at 77 K as compared with 1.4 dB for its gold counterpart. In an 'edge-coupled' configuration, the insertion loss went down from 0.9 dB for the gold film to 0.8 dB for the YBCO film at the same temperature.
Wideband bandpass filters employing broadside-coupled microstrip lines for MIC and MMIC applications
NASA Technical Reports Server (NTRS)
Tran, M.; Nguyen, C.
1994-01-01
Wideband bandpass filters employing half-wavelength broadside-coupled microstrip lines suitable for microwave and mm-wave integrated monolithic integrated circuits (MIC and MMIC) are presented. Several filters have been developed at X-band (8 to 12 GHz) with 1 dB insertion loss. Fair agreement between the measured and calculated results has been observed. The analysis of the broadside-coupled microstrip lines used in the filters, based on the quasi-static spectral domain technique, is also described.
Electrically heated particulate filter embedded heater design
Gonze, Eugene V.; Chapman, Mark R.
2014-07-01
An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine and wherein an upstream surface of the particulate filter includes machined grooves. A grid of electrically resistive material is inserted into the machined grooves of the exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu; Wagner, Daniel, E-mail: Daniel.Wagner@osumc.edu; Elliott, Eric, E-mail: Eric.Elliott@osumc.edu
PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15more » females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.« less
Abnormal location of umbilical venous catheter due to Scimitar syndrome
Mart, Christopher R; Van Dorn, Charlotte S
2014-01-01
Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705
Badjatia, Neeraj; O'Donnell, Joan; Baker, John R; Huang, David; Ayata, Cenk; Greer, David M; Carter, Bob S; Ogilvy, Christopher S; McDonald, Colin T
2004-01-01
Fever is common and difficult to control in patients with subarachnoid hemorrhage (SAH). We have previously shown an inverse relationship between fever and outcome in patients with SAH. This was a prospective, single-arm, feasibility trial in which nine patients with SAH underwent temperature management using an intravascular cooling catheter (ICC) to restore and maintain 24 hours of normothermia (36.5 degrees+/-0.2 degrees C). Enrollment occurred after development of a fever of at least 38.3 degrees C within 7 days of SAH that was refractory to acetaminophen treatment. The ICC was placed at the bedside through an introducer sheath via the femoral vein into the inferior vena cava (IVC). Portable X-ray confirmed placement. Normothermia was achieved in seven of the nine patients treated (78%); it was achieved in 100% of the patients with a 14F catheter (n=4) and in 60% of the patients with a 9F catheter (n=5). The two patients not reaching normothermia were not adequately treated for shivering. All other patients reached normothermia irrespective of intubation status. Overall, normothermia was well tolerated and not discontinued because of discomfort or adverse events. Two incidences of deep vein thrombosis were diagnosis by ultrasound that were not associated with clinical sequelae, and IVC filters were placed. No unanticipated adverse events occurred. We have demonstrated that fever can be safely and effectively controlled in patients with SAH for at least 24 hours using an ICC. Future studies are needed to assess the effect of such sustained therapy on outcome in patients with SAH.
Bypassing Races in Live Applications with Execution Filters
2010-01-01
LOOM creates the needed locks and semaphores on demand. The first time a lock or semaphore is refer- enced by one of the inserted synchronization ...runtime. LOOM provides a flexible and safe language for develop- ers to write execution filters that explicitly synchronize code. It then uses an...first compile their application with LOOM. At runtime, to workaround a race, an application developer writes an execution filter that synchronizes the
Agresti, Jeremy J.; Kelly, Bernard T.; Jäschke, Andres; Griffiths, Andrew D.
2005-01-01
In vitro compartmentalization (IVC) has previously been used to evolve protein enzymes. Here, we demonstrate how IVC can be applied to select RNA enzymes (ribozymes) for a property that has previously been unselectable: true intermolecular catalysis. Libraries containing 1011 ribozyme genes are compartmentalized in the aqueous droplets of a water-in-oil emulsion, such that most droplets contain no more than one gene, and transcribed in situ. By coencapsulating the gene, RNA, and the substrates/products of the catalyzed reaction, ribozymes can be selected for all enzymatic properties: substrate recognition, product formation, rate acceleration, and turnover. Here we exploit the complementarity of IVC with systematic evolution of ligands by exponential enrichment (SELEX), which allows selection of larger libraries (≥1015) and for very small rate accelerations (kcat/kuncat) but only selects for intramolecular single-turnover reactions. We selected ≈1014 random RNAs for Diels–Alderase activity with five rounds of SELEX, then six to nine rounds with IVC. All selected ribozymes catalyzed the Diels–Alder reaction in a truly bimolecular fashion and with multiple turnover. Nearly all ribozymes selected by using eleven rounds of SELEX alone contain a common catalytic motif. Selecting with SELEX then IVC gave ribozymes with significant sequence variations in this catalytic motif and ribozymes with completely novel motifs. Interestingly, the catalytic properties of all of the selected ribozymes were quite similar. The ribozymes are strongly product inhibited, consistent with the Diels–Alder transition state closely resembling the product. More efficient Diels–Alderases may need to catalyze a second reaction that transforms the product and prevents product inhibition. PMID:16260754
Arts and Crafts of the Mississippi Hills. ESEA, Title IV-C, 1982-83.
ERIC Educational Resources Information Center
Eaton, Barbara; Weatherford, Martha
An overview is presented of a 1982-83 Elementary and Secondary Education Act (ESEA), Title IV-C project, designed for 50 talented high school art students, to preserve the arts and crafts in the Mississippi hills area and to enrich existing arts and crafts curriculum. Steps are listed for implementing such a program, a simple program budget is…
An Application of the PMI Model at the Project Level Evaluation of ESEA Title IV-C Projects.
ERIC Educational Resources Information Center
McBeath, Marcia
All of the papers presented as part of a symposium concerned the application of the Planning, Monitoring, and Implementation Model (PMI) to the evaluation of the District of Columbia Public Schools' programs supported by the Elementary Secondary Education Act (ESEA) Title IV-C. PMI was developed to provide a model for systematic evaluation of…
Application of Change Agent Study Findings to the Formulation of Title IVC: Local Role.
ERIC Educational Resources Information Center
Weinman, Janice
This paper addresses three issues--current constraints on the local level that contribute to failures to bring about innovation, conditions that have been isolated as significant to the success of the change process, and ways in which Title IV-C of the Elementary and Secondary Education Act could encourage the presence of these favorable…
NASA Astrophysics Data System (ADS)
Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison
2010-11-01
The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.
Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew
2018-05-04
Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.
Switchable multiwavelength thulium-doped fiber ring lasers
NASA Astrophysics Data System (ADS)
Zhao, Shui; Lu, Ping; Liu, Deming; Zhang, Jiangshan
2013-08-01
Two kinds of thulium-doped fiber ring lasers based on a spatial mode beating filter and comb filtering effect are presented and experimentally demonstrated, which all show multiwavelength laser spectrum around 2 μm. In the implementation of the first type of experiment configuration by the use of a piece of multimode fiber (MMF) as a spatial mode beating filter, dual-,triple-, and quadruple-wavelengths appeared whose extinction noise ratio is 25 dB by adjusting the angle of polarization controller. Different wavelength spaces are obtained by inserting different lengths of MMF. The second type is achieved by inserting a Sagnac loop mirror, which was constructed by a 3-dB coupler and a piece of polarization maintaining fiber. Seven stable wavelengths with channel spacing of 0.65 nm and an extinction ratio of 35 dB was achieved. These systems are simple and easy to construct, which can be useful for 2 μm wavelength-division-multiplexed applications.
Regan, John Frederick
2014-09-09
Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.
2018-04-17
Mucositis; Oral Complications; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Adenoid Cystic Carcinoma of the Oral Cavity; Stage I Basal Cell Carcinoma of the Lip; Stage I Lymphoepithelioma of the Nasopharynx; Stage I Lymphoepithelioma of the Oropharynx; Stage I Mucoepidermoid Carcinoma of the Oral Cavity; Stage I Salivary Gland Cancer; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Nasopharynx; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Adenoid Cystic Carcinoma of the Oral Cavity; Stage II Basal Cell Carcinoma of the Lip; Stage II Lymphoepithelioma of the Nasopharynx; Stage II Lymphoepithelioma of the Oropharynx; Stage II Mucoepidermoid Carcinoma of the Oral Cavity; Stage II Salivary Gland Cancer; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Nasopharynx; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Adenoid Cystic Carcinoma of the Oral Cavity; Stage III Basal Cell Carcinoma of the Lip; Stage III Lymphoepithelioma of the Nasopharynx; Stage III Lymphoepithelioma of the Oropharynx; Stage III Mucoepidermoid Carcinoma of the Oral Cavity; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
2017-04-19
Human Papilloma Virus Infection; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx
Mice prefer draught-free housing.
Krohn, T C; Hansen, A K
2010-10-01
An increasing number of rodents are housed in individually ventilated cage (IVC) systems, as these seem to be very effective for the protection of animals against infections, as well as protecting the staff against allergens. For the IVC systems to be properly ventilated, a huge amount of air has to be blown into the cage, which may cause a draught at animal level inside the cage. The aim of the present study was to evaluate the preferences of mice for differing levels of air speeds and air changes inside the cage. It has been concluded that mice do react to draughts, whereas they do not seem to be affected by a high number of air changes delivered without draught, which underlines the importance of applying draught-free IVC systems for mice.
Physiologic Effect of Stent Therapy for Inferior Vena Cava Obstruction Due to Malignant Liver Tumor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kishi, Kazushi; Sonomura, Tetsuo; Fujimoto, Hisashi
Purpose. To understand systemic the influence of stent therapy for inferior vena cava (IVC) obstruction due to advanced liver tumor. Methods. Seven patients with symptomatic IVC obstruction due to advanced primary (n 4) or secondary (n = 3) liver tumor were subjected to stent therapy. Enrollment criteria included high IVC pressure over 15 mmHg and the presence of edema and ascites. Z-stents were deployed using coaxial sheath technique via femoral venous puncture. Physiologic and hematobiochemical parameters were analyzed. Results. All procedures were successful, and the stents remained patent until patient death. Promptly after stent placement, the IVC flow recovered, andmore » the venous blood pressure in the IVC below the obstruction level showed a significant decrease from 20.8 {+-} 1.2 mmHg (mean {+-} SE) to 10.7 {+-} 0.7 mmHg (p < 0.01). Transient mild increase of right atrial pressure was observed in 1 patient. During the following week prominent diuresis was observed in all patients. Mean urine output volume in the 3 days before the stent therapy was 0.81 {+-} 0.09 l/day compared with 2.1 {+-} 0.2 l/day (p < 0.01) in the 3 days after. The edema and ascites decreased in all patients. The caval pressure change correlated well (r > 0.6) with the urine volume increase, and with the decreased volume of edema and ascites. The urine volume increase correlated well with the decrement of edema, but not with that of ascites. Improvements for various durations in the levels of blood urea nitrogen, serum creatinine, lactate dehydrogenase, fibrinogen, and platelet count were found (p < 0.05). These hematobiochemical changes were well correlated with each other and with the decrement of ascites. Two patients showed a low blood sodium level of 128.5 mEq/l after intensive natriuresis, and one of them died on day 21 with hepatic failure, which was interpreted as maladaptation aggravation. The mean survival time was 94.1 {+-} 34.1 days (mean {+-} SD), ranging from 21 to 140 days after stent treatment. Conclusion. The stent therapy for IVC obstruction due to malignant liver tumors was followed by a series of physiologic and hematobiochemical consequences, most of them favorable but some possibly unfavorable. Rational interpretations and predictions of sequelae based on physiologic science including cardiology, hepatology, and nephrology would facilitate the best management of stent therapy for malignant IVC obstruction.« less
Effect of high-dose intravenous vitamin C on inflammation in cancer patients.
Mikirova, Nina; Casciari, Joseph; Rogers, Andrea; Taylor, Paul
2012-09-11
An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer.Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels.Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods.CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment.There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein.Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels.In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted.
Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.
Satyapal, K S
1999-10-01
Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral level of entry of renal veins into IVC in foetuses. These findings are clinically important for the angiographer, catheter design, and planning porto-renal shunt procedures. Copyright 1999 Wiley-Liss, Inc.
Effect of high-dose intravenous vitamin C on inflammation in cancer patients
2012-01-01
Background An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer. Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels. Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. Methods 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods. CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. Results According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment. There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein. Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. Conclusions The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels. In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted. PMID:22963460
New data on selected Ivory Coast tektites
Cuttitta, F.; Carron, M.K.; Annell, C.S.
1972-01-01
Fourteen Ivory Coast tektites exhibit a range of bulk indices of refraction of 1.5156 to 1.5217 ?? 0.0004 and of bulk specific gravities of 2.428 to 2.502 ??0.005. Seven of these Ivory Coast (IVC) tektites were analyzed for major and minor element content. Compared to tektites from other strewn fields, their SiO2 content is low (67.2-69.1 %), A12O3 relatively high (15.8-16.8 %), and total iron relatively high but with a more restricted range (6.3-6.8 % as FeO). Their lime content is low (0.71-1.35%) compared to Australasian tektites but their MgO CaO ratio (about 3.1) is unusually high. All other tektite groups have Na2O K2O ratios less than unity, but the Na2O K2O ratio of the IVC tektites is slightly greater than unity. Their K Rb ratios range from 200 to 256 and average 227, which is higher than those determined for Australasian tektites, but similar to some obtained for moldavites. The Li content (41-48 ppm) is about the same as that of the Australasian tektites, but the Cs and Rb are lower, being 1.9 to 2.9 and 57 to 86 ppm, respectively. The IVC tektites are high in Cr (260-375 ppm), Co (19-25 ppm) and Ni (101-167 ppm), and particularly in Pb (<10-18 ppm), Cu (13-21 ppm) and Ga (14-23 ppm). The high Cr Ni ratios of the IVC tektites (range 2-3.6) are similar to those found for australites, philippinites and thailandites, but not the javanites and indochinites. Evaluation of these and other reported data show that compositional similarities between the IVC tektites and green or black Bosumtwi Crater glasses strongly support the hypothesis of a common impact origin-i.e. the Bosumtwi Crater site. Comparison of the IVC tektite composition with those of returned lunar materials (gabbros, basalts, breccia and soils) do not support a lunar origin for the Ivory Coast tektites. ?? 1972.
Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.
Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok
2016-09-01
Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%). Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.
Inferior vena cava segmentation with parameter propagation and graph cut.
Yan, Zixu; Chen, Feng; Wu, Fa; Kong, Dexing
2017-09-01
The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of [Formula: see text], an MSD of [Formula: see text] mm, and a MaxD of [Formula: see text] mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.
Sepúlveda, Lilian; Bussalleu, Eva; Yeste, Marc; Bonet, Sergi
2016-05-01
Several studies have reported the detrimental effects that bacteriospermia causes on boar sperm quality, but little is known about its effects on IVC. Considering that, the present study sought to evaluate the effects of different concentrations of Pseudomonas aeruginosa on different indicators of capacitation status (sperm viability, membrane lipid disorder, sperm motility kinematics, and protein phosphorylation of boar spermatozoa) after IVC. Flow cytometry and computer assisted sperm analysis (CASA) revealed that the presence of P aeruginosa in boar sperm samples, mostly at concentrations greater than 10(6) CFU/mL, is associated with a significant (P < 0.05) decrease in the percentages of both sperm membrane integrity and sperm with low membrane lipid disorder, and also with a reduction in sperm motility kinetic parameters when compared with results obtained from the control sample, which presented the typical motility pattern of capacitated-like boar spermatozoa. Moreover, Western blot results also showed significant (P < 0.05) changes in the levels of tyrosine, serine, and threonine protein phosphorylation because of bacterial contamination, the decrease in phosphotyrosine levels of p32, a well-known marker of IVC achievement in boar sperm, being the most relevant. Indeed, after 3 hours of IVC, phosphotyrosine levels of p32 in the control sample were 3.13 ± 0.81, whereas in the tubes with 10(6) and 10(8) CFU/mL were 1.05 ± 0.20 and 0.36 ± 0.07, respectively. Therefore, the present study provides novel data regarding the effects of bacterial contamination on boar sperm, suggesting that the presence of P aeruginosa affects the fertilizing ability of boar sperm by altering its ability to accomplish IVC. Copyright © 2016 Elsevier Inc. All rights reserved.
Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.
Heiligers-Duckers, Connie; Peters, Nathalie A L R; van Dijck, Jose J P; Hoeijmakers, Jan M J; Janssen, Marcel J W
2013-08-01
In-vitro hemolysis is a great challenge to emergency departments where blood is drawn from intravenous catheters (IVCs). Although high quality samples can be obtained by straight needle venipuncture, IVCs are preferred for various reasons. The aim of this study was to identify blood collection practices that reduce hemolysis while using IVC. The study was conducted at an emergency department where blood is drawn in ≥ 90% of patients from IVC. Hemolysis, measured spectrophotometrically, was compared between syringe and vacuum tubes. The following practices were tested in combination with vacuum collection; a Luer-slip adapter, a Luer-lock adapter, discard tubes and low vacuum tubes. Each intervention lasted 1 week and retrieved 154 to 297 samples. As reference, hemolysis was also measured in vacuum tubes retrieved from departments where only straight needle venipuncture is performed. Vacuum collection led to more hemolytic samples compared with syringe tubes (24% versus 16% respectively, p=0.008). No difference in hemolysis was observed between the Luer-slip and the Luer-lock adapter. The use of discard (17% hemolytic, p=0.045) and low vacuum tubes (12% hemolytic, p<0.001) substantially decreased hemolysis. None of the interventions reduced the hemolysis rate to the level observed when drawing blood by straight needle venipuncture (3%, p<0.02). In summary, both discard and low vacuum tubes reduce hemolysis while drawing blood from IVC. Of these practices the use of a low vacuum tube is preferred considering the less volume of blood and the amount of tubes drawn. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Viteri Malone, Mariuxi A; Ares, Gustavo Ruiz; De Velasco, Guillermo; Brandão, Raphael; Lin, Xun; Norton, Craig; Simantov, Ronit; Moslehi, Javid; Krajewski, Katherine M; Choueiri, Toni K; McKay, Rana R
2018-04-01
Cardiac metastases from renal cell carcinoma (RCC) are uncommon and there are limited data regarding the presentation and outcomes of this population. The objective of this study was to evaluate the characteristics and outcomes of patients with RCC with cardiac metastasis without inferior vena cava (IVC) involvement. We conducted a pooled retrospective analysis of metastatic RCC patients treated in 4 clinical trials. Additionally, we conducted a systematic review of cases reported in the literature from 1973 to 2015. Patients with cardiac metastases from RCC without IVC involvement were included. Patient and disease characteristics were described. Additionally, treatments, response to therapy, and survival outcomes were summarized. Of 1765 metastatic RCC patients in the clinical trials database, 10 had cardiac metastases without IVC involvement. All patients received treatment with targeted therapy. There was 1 observed partial response (10%) and 6 patients showed stable disease (60%). The median progression-free survival was 6.9 months. The systematic review of reported clinical cases included 39 patients. In these patients, the most common cardiac site of involvement was the right ventricle (51%; n = 20). Patients were treated with medical (28%; n = 11) and/or surgical treatment (49%; n = 19) depending on whether disease was isolated (n = 13) or multifocal (n = 26). To our knowledge, this is the first series to report on the presentation and outcomes of patients with cardiac metastasis without IVC involvement in RCC. We highlight that although the frequency of patients with cardiac metastases without IVC involvement is low, these patients have a unique clinical presentation and warrant special multidisciplinary management. Copyright © 2017 Elsevier Inc. All rights reserved.
Bertel, Noemi; Witassek, Fabienne; Puhan, Milo; Erne, Paul; Rickli, Hans; Naegeli, Barbara; Pedrazzini, Giovanni; Stauffer, Jean-Christophe; Radovanovic, Dragana
2017-03-01
Diagnosis of acute myocardial infarction (MI) is challenging in pacemaker patients. Little is known about this patient group. Patients with MI enrolled in the Swiss national AMIS Plus registry between January 2005 and December 2015 were analyzed. All patients with either paced ventricular rhythm or sinus rhythm with intrinsic ventricular conduction (IVC) were included in this study. Outcomes using crude data and propensity score matching were compared between patients with pacemaker rhythm and patients with IVC. The primary endpoint was in-hospital death. Data from 300 patients with paced rhythm and 27,595 with IVC were analyzed. Patients with pacemaker rhythm were older (78.2y vs 65.4y; p<0.001), had more comorbidities (Charlson Index (CCI)>1: 54.0% vs 21.1%; p<0.001) and a higher rate of heart failure upon presentation (Killip class>2, 11.0% vs 5.9%; p<0.001) compared to patients with IVC. Door to balloon time in patients undergoing acute PCI is markedly delayed in contrast to patients with IVC (280min vs 85min; p<0.001). Consequently, crude mortality in patients with pacemakers was high (11.3% vs 4.6%; p<0.001). However, when analyzed with propensity matching for gender, age, CCI>1 and Killip>2, mortality was similar (11.2% vs 10.5%; p=0.70). Pacemaker patients with acute MI represent a high-risk group with doubled crude mortality compared to patients without pacemakers, due to higher age and higher Killip class. Diagnosis is difficult and results in delayed treatment. Treatment algorithms for MI with paced rhythm should possibly be adapted to those used for STEMI or new left bundle branch block. NCT01305785. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Gao, Qingzhen; Wang, Xiaoping; Zhang, Ruibin; Wang, Pu; Jing, Yongsheng; Ren, Wanjun; Zhu, Bin
2016-07-01
The study aimed to compare the impact of allogeneic bone marrow cells (BMCs) infusion through the inferior vena cava (IVC) and portal vein (PV) combined with rapamycin on allogeneic islet grafts in diabetic rats. Recipient diabetic Wistar rats were infused with islets from Sprague-Dawley rats through the PV. PKH26-labeled BMCs of Sprague-Dawley rats were infused to recipients through the PV or IVC, followed by administration of rapamycin for 4 days. Blood glucose level was measured to evaluate the survival time of the islets. Lymphocytes separated from blood, BMCs, thymus, liver, spleen and lymph node were analyzed by flow cytometry. The peripheral blood smear, BMCs smear and frozen sections of tissues were observed by a fluorescence microscope. The survival time of the islets was significantly prolonged by the BMCs infusion combined with rapamycin. The rats receiving BMCs infusion through the PV induced a significantly longer survival time of the islets, and increased mixed chimeras of allogeneic BMCs in the thymus, liver, spleen and lymph node compared with the rats receiving BMCs infusion through the IVC. The amount of the mixed chimeras on day 14 was lower than that on day 7 after islet transplantation. Furthermore, PV transplantation had significantly more mixed chimera than IVC transplantation in all analyzed organs or tissues. BMCs infusion combined with rapamycin prolongs the islets survival and induces mixed chimeras of BMCs. PV infusion of BMCs might be a more effective strategy than IVC infusion of BMCs. © 2015 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Radar range data signal enhancement tracker
NASA Technical Reports Server (NTRS)
1975-01-01
The design, fabrication, and performance characteristics are described of two digital data signal enhancement filters which are capable of being inserted between the Space Shuttle Navigation Sensor outputs and the guidance computer. Commonality of interfaces has been stressed so that the filters may be evaluated through operation with simulated sensors or with actual prototype sensor hardware. The filters will provide both a smoothed range and range rate output. Different conceptual approaches are utilized for each filter. The first filter is based on a combination low pass nonrecursive filter and a cascaded simple average smoother for range and range rate, respectively. Filter number two is a tracking filter which is capable of following transient data of the type encountered during burn periods. A test simulator was also designed which generates typical shuttle navigation sensor data.
Malignant phyllodes tumour presenting as a massive fungating breast mass and silent thrombo-embolism
Bourke, Anita G.; McCreanor, Madeleine; Yeo, Allen; Weber, Dieter; Bartlett, Anthony; Backhouse, Anastasia
2015-01-01
Introduction We report an unusual case of a massive malignant phyllodes tumour that had almost replaced the entire breast presenting with severe chronic blood loss, extensive deep venous thrombosis (DVT) and a silent pulmonary embolus. Presentation Long-standing neglected massive fungating ulcerative mass larger than the left haemothorax. Discussion Phyllodes tumours are rare fibro-epithelial breast lesions that have the propensity to grow rapidly to a large size if neglected. Larger tumours are more likely to be malignant with an overall metastatic rate around 10%. An incidental pulmonary embolus arising from extensive silent lower limb deep vein thrombosis requiring an IVC filter complicated the surgical management. Conclusion Phyllodes tumours are rare and account for approximately 0.3–0.5% of all breast tumours [1]. They have the propensity to be fast growing. However, tumours reaching a massive size (>10 cm) are rare with few reports in the literature. PMID:25734318
2018-05-15
Metastatic Thyroid Gland Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma
ERIC Educational Resources Information Center
Texas A and M Univ., College Station. Vocational Instructional Services.
Part of a series of eight student learning modules in vocational agriculture, this booklet deals with crop-related activities. The first section is on harvesting methods and equipment. The following portions address the handling, grading, and packing of crops; and the classification and selection of fruits, vegetables, and ornamental plants. There…
Maciel, James D; Plurad, David; Gifford, Edward; deVirgilio, Christian; Koopmann, Matt; Neville, Angela; Putnam, Brant; Kim, Dennis Y
2015-10-01
Inferior vena cava (IVC) injuries are associated with significant morbidity and mortality. To identify clinical factors associated with mortality in patients undergoing operative intervention for penetrating IVC injuries, a retrospective review of 98 patients was performed, excluding blunt injuries (n = 20) and deaths before surgery (n = 16). The overall mortality was 58 per cent. Nonsurvivors more commonly presented with hypotension (50% vs 23%, P = 0.03) and underwent resuscitative thoracotomy more frequently (42% vs 4%, P = 0.01). Retrohepatic injuries were more common among nonsurvivors (P = 0.04). There was no difference in the use of ligation (7% vs 17%, P = 0.29) or the massive transfusion protocol (35% vs 25%, P = 0.41). On multivariate analysis, after controlling for mechanism of injury, admission hypotension, Glasgow Coma Scale score , preoperative cumulative fluids, resuscitative thoracotomy , absence of spontaneous tamponade, and location of IVC injury, the only independent predictor of mortality was the absence of spontaneous tamponade at the time of laparotomy (odds ratio = 5.4, 95% confidence interval: 1.11-25.95; P = 0.04). Penetrating IVC injuries continue to be associated with a high mortality, particularly among patients with free intraabdominal hemorrhage at laparotomy. Large multicenter studies are required to define the optimal resuscitative and operative management techniques in these severely injured patients.
2018-04-26
Caregiver; Malignant Head and Neck Neoplasm; Paranasal Sinus Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage I Hypopharyngeal Squamous Cell Carcinoma; Stage I Laryngeal Squamous Cell Carcinoma; Stage I Lip and Oral Cavity Squamous Cell Carcinoma; Stage I Oropharyngeal Squamous Cell Carcinoma; Stage II Hypopharyngeal Squamous Cell Carcinoma; Stage II Laryngeal Squamous Cell Carcinoma; Stage II Lip and Oral Cavity Squamous Cell Carcinoma; Stage II Oropharyngeal Squamous Cell Carcinoma; Stage III Hypopharyngeal Squamous Cell Carcinoma; Stage III Laryngeal Squamous Cell Carcinoma; Stage III Lip and Oral Cavity Squamous Cell Carcinoma; Stage III Oropharyngeal Squamous Cell Carcinoma; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Laryngeal Squamous Cell Carcinoma; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma; Stage IV Oropharyngeal Squamous Cell Carcinoma; Stage IVA Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Hypopharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Hypopharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma
Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave
2015-11-04
We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.
High-Tc superconductor coplanar waveguide filter
NASA Technical Reports Server (NTRS)
Chew, Wilbert; Bajuk, Louis J.; Cooley, Thomas W.; Foote, Marc C.; Hunt, Brian D.; Rascoe, Daniel L.; Riley, A. L.
1991-01-01
Coplanar waveguide (CPW) low-pass filters made of YBa2Cu3O(7-delta) (YBCO) on LaAlO3 substrates, with dimensions suited for integrated circuits, were fabricated and packaged. A complete filter gives a true idea of the advantages and difficulties in replacing thin-film metal with a high-temperature superconductor in a practical circuit. Measured insertion losses in liquid nitrogen were superior to the loss of a similar thin-film copper filter throughout the 0- to 9.5-GHz passband. These results demonstrate the performance of fully patterned YBCO in a practical CPW structure after sealing in a hermetic package.
Kim, Myoung Jin; Jung, Yong Min; Kim, Bok Hyeon; Han, Won-Taek; Lee, Byeong Ha
2007-08-20
We demonstrate a fiber-based bandpass filter with an ultra-wide spectral bandwidth. The ultra-wide band feature is achieved by inscribing a long-period fiber grating (LPG) in a specially-designed low index core single mode fiber. To get the bandpass function, the evanescent field coupling between two attached fibers is utilized. By applying strain, the spectral shape of the pass-band is adjusted to flat-top and Gaussian shapes. For the flat-top case, the bandwidth is obtained ~ 160 nm with an insertion loss of ~ 2 dB. With strain, the spectral shape is switched into a Gaussian one, which has ~ 120 nm FWHM and ~ 4.18 dB insertion loss at the peak.
Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew
2014-01-01
Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.
Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L
2010-02-01
A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel
A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less
Supra hepatic inferior vena cava and right atrial thrombosis following a traffic car crash.
Sabzi, Feridoun; Karim, Hosein; Haghi, Marjan
2016-07-01
We present a case of nephrotic syndrome associated with right atrial and supra hepatic vein part of inferior vena caval thrombosis. This patient presented with dyspena, lower extremity edema and back pain after a vehicle accident and blunt trauma to the abdomen. Trauma should be considered not only as a thrombophilic pre-disposition, but also as a predisposing factor to IVC endothelium injury and thrombosis formation. Echocardiography revealed supra hepatic vein IVC thrombosis floating to the right atrium. A C-T scan with contrast also showed pulmonary artery emboli to the left upper lobe. With open heart surgery, the right atrial and IVC clot were extracted and the main left and right pulmonary arteries were evaluated for possible clot lodging. The patient had an uneventful postoperative recovery and thrombosis has not reoccurred with periodical follow-up examinations. © 2016 KUMS, All rights reserved.
Lenvatinib and Pembrolizumab in DTC
2018-05-21
Columnar Cell Variant Thyroid Gland Papillary Carcinoma; Follicular Variant Thyroid Gland Papillary Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Follicular Carcinoma AJCC v7; Stage III Thyroid Gland Papillary Carcinoma AJCC v7; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7; Tall Cell Variant Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma
Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef
2017-10-01
The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P < 0.001). Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.
Noise elimination method using a transmission line for the diagnostics of radio frequency plasma
NASA Astrophysics Data System (ADS)
Shimizu, K.; Hallil, A.; Amemiya, H.
1997-04-01
A filter using a transmission line formed by a cascade connection of inverted L-type networks has been developed to reject the distortion of the probe characteristics by rf (radio-frequency) noise. Each inverse L network consists of two coaxial cables with the same physical constant and length. The filter can remove discrete frequency components including the fundamental and harmonic components, the cut-off frequencies being determined by the distributed circuit constant and the length of the cables. By inserting different kinds of the network in cascade, many noise components associated with the rf frequency can be eliminated at the end section of the filter. Experiments have been performed in rf plasmas by inserting three kinds of inverted L networks with the frequency f (13.56 MHz), 2 f and 4f as the cut-off frequency. Distortion free probe characteristics have been obtained, from which accurate determination of plasma parameter such as the electron energy distribution is possible.
Stabilizing an optoelectronic microwave oscillator with photonic filters
NASA Technical Reports Server (NTRS)
Strekalov, D.; Aveline, D.; Yu, N.; Thompson, R.; Matsko, A. B.; Maleki, L.
2003-01-01
This paper compares methods of active stabilization of an optoelectronic microwave oscillator (OEO) based on insertion of a source of optical group delay into an OEO loop. The performance of an OEO stabilized with either a high- optical cavity or an atomic cell is analyzed. We show that the elements play a role of narrow-band microwave filters improving an OEO stability.
Hu, Ming Zhe; Zhang, Hao Chi; Yin, Jia Yuan; Ding, Zhao; Liu, Jun Feng; Tang, Wen Xuan; Cui, Tie Jun
2016-01-01
Novel ultra-wideband filtering of spoof surface plasmon polaritons (SPPs) is proposed in the microwave frequency using deep subwavelength planar structures printed on thin and flexible dielectric substrate. The proposed planar SPPs waveguide is composed of two mirror-oriented metallic corrugated strips, which are further decorated with parallel-arranged slots in the main corrugated strips. This compound structure provides deep subwavelength field confinement as well as flexible parameters when employed as a plasmonic waveguide, which is potential to construct miniaturization. Using momentum and impedance matching technology, we achieve a smooth conversion between the proposed SPPs waveguide and the conventional transmission line. To verify the validity of the design, we fabricate a spoof SPPs filter, and the measured results illustrate excellent performance, in which the reflection coefficient is less than −10 dB within the −3 dB passband from 1.21 GHz to 7.21 GHz with the smallest insertion loss of 1.23 dB at 2.21 GHz, having very good agreements with numerical simulations. The ultra-wideband filter with low insertion loss and high transmission efficiency possesses great potential in modern communication systems. PMID:27883028
Hu, Ming Zhe; Zhang, Hao Chi; Yin, Jia Yuan; Ding, Zhao; Liu, Jun Feng; Tang, Wen Xuan; Cui, Tie Jun
2016-11-24
Novel ultra-wideband filtering of spoof surface plasmon polaritons (SPPs) is proposed in the microwave frequency using deep subwavelength planar structures printed on thin and flexible dielectric substrate. The proposed planar SPPs waveguide is composed of two mirror-oriented metallic corrugated strips, which are further decorated with parallel-arranged slots in the main corrugated strips. This compound structure provides deep subwavelength field confinement as well as flexible parameters when employed as a plasmonic waveguide, which is potential to construct miniaturization. Using momentum and impedance matching technology, we achieve a smooth conversion between the proposed SPPs waveguide and the conventional transmission line. To verify the validity of the design, we fabricate a spoof SPPs filter, and the measured results illustrate excellent performance, in which the reflection coefficient is less than -10 dB within the -3 dB passband from 1.21 GHz to 7.21 GHz with the smallest insertion loss of 1.23 dB at 2.21 GHz, having very good agreements with numerical simulations. The ultra-wideband filter with low insertion loss and high transmission efficiency possesses great potential in modern communication systems.
NASA Astrophysics Data System (ADS)
Niwa, Masaki; Takashina, Shoichi; Mori, Yojiro; Hasegawa, Hiroshi; Sato, Ken-ichi; Watanabe, Toshio
2015-01-01
With the continuous increase in Internet traffic, reconfigurable optical add-drop multiplexers (ROADMs) have been widely adopted in the core and metro core networks. Current ROADMs, however, allow only static operation. To realize future dynamic optical-network services, and to minimize any human intervention in network operation, the optical signal add/drop part should have colorless/directionless/contentionless (C/D/C) capabilities. This is possible with matrix switches or a combination of splitter-switches and optical tunable filters. The scale of the matrix switch increases with the square of the number of supported channels, and hence, the matrix-switch-based architecture is not suitable for creating future large-scale ROADMs. In contrast, the numbers of splitter ports, switches, and tunable filters increase linearly with the number of supported channels, and hence the tunable-filter-based architecture will support all future traffic. So far, we have succeeded in fabricating a compact tunable filter that consists of multi-stage cyclic arrayed-waveguide gratings (AWGs) and switches by using planar-lightwave-circuit (PLC) technologies. However, this multistage configuration suffers from large insertion loss and filter narrowing. Moreover, power-consuming temperature control is necessary since it is difficult to make cyclic AWGs athermal. We propose here novel tunable-filter architecture that sandwiches a single-stage non-cyclic athermal AWG having flatter-topped passbands between small-scale switches. With this configuration, the optical tunable filter attains low insertion loss, large passband bandwidths, low power consumption, compactness, and high cost-effectiveness. A prototype is monolithically fabricated with PLC technologies and its excellent performance is experimentally confirmed utilizing 80-channel 30-GBaud dual-polarization quadrature phase-shift-keying (QPSK) signals.
Performance Enhancement of Tunable Bandpass Filters Using Selective Etched Ferroelectric Thin Films
NASA Technical Reports Server (NTRS)
Miranda, Felix A.; Mueller, Carl H.; VanKeuls, Fred W.; Subramanyam, Guru; Vignesparamoorthy, Sivaruban
2003-01-01
The inclusion of voltage-tunable barium strontium titanate (BSTO) thin films into planar band pass filters offers tremendous potential to increase their versatility. The ability to tune the passband so as to correct for minor deviations in manufacturing tolerances, or to completely reconfigure the operating frequencies of a microwave communication system, are highly sought-after goals. However, use of ferroelectric films in these devices results in higher dielectric losses, which in turn increase the insertion loss and decrease the quality factors of the filters. This study explores the use of patterned ferroelectric layers to minimize dielectric losses without degrading tunability. Patterning the ferroelectric layers enables us to constrict the width of the ferroelectric layers between the coupled microstrip lines, and minimize losses due to ferroelectric layers. Coupled one-pole microstrip bandpass filters with fundamental resonances at approx. 7.2 GHz and well defined harmonic resonances at approx. 14.4 and approx. 21.6 GHz, were designed, simulated and tested. For one of the filters, experimental results verified that its center frequency was tunable by 528 MHz at a center frequency of 21.957 GHz, with insertion losses varying from 4.3 to 2.5 dB, at 0 and 3.5 V/micron, respectively. These data demonstrate that the tuning-to-loss figure of merit of tunable microstrip filters can be greatly improved using patterned ferroelectric thin films as the tuning element, and tuning can be controlled by engineering the ferroelectric constriction in the coupled sections.
Study on virtual instrument developing system based on intelligent virtual control
NASA Astrophysics Data System (ADS)
Tang, Baoping; Cheng, Fabin; Qin, Shuren
2005-01-01
The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.
2001-10-25
a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV
Stamp, A.J.; Dorman, M.L.; Vernazza, C.R.; Deeming, G.; Reid, C.; Wilson, K.E.; Girdler, N.M.
2017-01-01
Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care is often provided under GA. Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine its use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care. Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS midazolam. Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescent, 98.9% (n=172) allowed cannulation with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7mg with 79.1% patients having good or excellent co-operation and three minor adverse events occurring. Conclusion This service evaluation shows IVCS midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA. PMID:28127013
Thrombosis of the inferior vena cava and malignant disease.
Kraft, Christiane; Schuettfort, Gundolf; Weil, Yvonne; Tirneci, Vanessa; Kasper, Alexander; Haberichter, Barbara; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit
2014-09-01
Inferior vena cava thrombosis (IVCT) is a rare event, and studies detailing its underlying aetiologies are scarce. One hundred and forty-one IVCT patients (57% females, median age 47 years) were analysed with a focus on malignancy-related thrombosis and compared with 141 age- and sex-matched control patients with isolated lower-extremity deep vein thrombosis. Malignancies were more prevalent among IVCT patients compared with the control group (39% vs. 7.8%; P<0.001). Malignancy-related IVCT more frequently involved the suprarenal and hepatic segments of the IVC and extended more often to the right atrium than IVCT did in non-cancer patients. Among IVCT patients with malignancies, renal cell carcinoma (38%) and other malignancies of the genitourinary tract (25%) were the most common tumours. Analysis of the underlying pathological mechanisms of malignancy-related thrombosis identified external compression of the IVC by tumour masses in 9 cases (16%), and progression of malignancy into the IVC (so-called "tumour thrombosis") in 24 cases (44%). The remaining 22 cases (40%) were attributed to malignancy-related hypercoagulability and the presence of additional venous thromboembolism risk factors, such as previous surgery, immobilisation, or chemotherapy. Malignancies substantially contribute to the risk of thrombosis involving the IVC. Tumour invasion, especially in cases of renal cell cancer and malignancy-related hypercoagulability are major triggering factors for thrombogenesis. Copyright © 2014. Published by Elsevier Ltd.
Linnemann, Birgit; Kraft, Christiane; Roskos, Martin; Zgouras, Dimitrios; Lindhoff-Last, Edelgard
2012-06-01
Splanchnic vein thrombosis (SVT) is a typical manifestation of polycythaemia vera (PV) or essential thrombocythaemia (ET). The recently discovered JAK2V617F somatic mutation is closely associated with chronic myeloproliferative disease (CMD). We investigated whether thrombosis involving the inferior vena cava (IVC) is also related to the JAK2V617F mutation or CMD. Blood samples were obtained from 40 IVC thrombosis patients. Fifty-three patients with isolated lower extremity deep vein thrombosis (LE-DVT) and 20 SVT patients served as controls. The presence of the JAK2V617F mutation was assessed by real-time polymerase chain reaction (RT-PCR). The JAK2V617F allele was not detected in any of the IVC thrombosis patients but was detected in one patient (2%) with isolated LE-DVT. However, the mutation-carrying patient did not exhibit symptoms of CMD. Even after an observation period of 30months, the patient's complete blood cell count did not exhibit any pathology. In contrast, the JAK2V617F allele was detected in four patients with SVT (20%) and CMD. According to our data, there is no evidence that IVC thrombosis is associated with the JAK2V617F mutation or the presence of chronic myeloproliferative disease. Copyright © 2011 Elsevier Ltd. All rights reserved.
2018-02-02
Head and Neck Basaloid Carcinoma; Recurrent Head and Neck Squamous Cell Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma of Unknown Primary Origin; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IV Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Head and Neck Cancer; Oropharyngeal Cancer; HNSCC
Stamp, A J; Dorman, M L; Vernazza, C R; Deeming, G; Reid, C; Wilson, K E; Girdler, N M
2017-01-27
Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care can often be provided under general anaesthesia (GA). Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care.Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS with midazolam.Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescents, 98.9% (N = 172) allowed cannulation, with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7 mg with 79.1% of patients having good or excellent cooperation and three minor adverse events occurring.Conclusion This service evaluation shows IVCS with midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA.
Impact of Chronic Rheumatic Valve Diseases on Large Vessels.
Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet
2016-01-01
BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.
Youm, Hye Won; Lee, Jung Ryeol; Lee, Jaewang; Jee, Byung Chul; Suh, Chang Suk; Kim, Seok Hyun
2014-04-01
What is the optimal vitrification protocol according to the cryoprotective agent (CPA) for ovarian tissue (OT) cryopreservation? The two-step protocol with 7.5% ethylene glycol (EG) and 7.5% dimethyl sulfoxide (DMSO) for 10 min then 20% EG, 20% DMSO and 0.5 M sucrose for 5 min showed the best results in mouse OT vitrification. Establishing the optimal cryopreservation protocol is one of the most important steps to improve OT survival. However, only a few studies have compared vitrification protocols with different CPAs and investigated the effect of in vitro culture (IVC) on vitrified-warmed OT survival. Some recent papers proposed that a combination of CPAs has less toxicity than one type of CPA. However, the efficacy of different types and concentrations of CPA are not yet well documented. A total of 644 ovaries were collected from 4-week-old BDF1 mice, of which 571 ovaries were randomly assigned to 8 groups and vitrified using different protocols according to CPA composition and the remaining 73 ovaries were used as controls. After warming, each of the eight groups of ovaries was further randomly divided into four subgroups and in vitro cultured for 0, 0.5, 2 and 4 h, respectively. Ovaries of the best two groups among the eight groups were autotransplanted after IVC. The CPA solutions for the eight groups were composed of EDS, ES, ED, EPS, EF, EFS, E and EP, respectively (E, EG; D, DMSO; P, propanediol; S, sucrose; F, Ficoll). The IVC medium was composed of α-minimal essential medium, 10% fetal bovine serum and 10 mIU/ml follicle-stimulating hormone (FSH). Autotransplantation of vitrified-warmed OTs after IVC (0 to 4 h) using the EDS or ES protocol was performed, and the grafts were recovered after 3 weeks. Ovarian follicles were assessed for morphology, apoptosis, proliferation and FSH level. The percentages of the morphologically intact (G1) and apoptotic follicles in each group at 0, 0.5, 2 and 4 h of IVC were compared. For G1 follicles at 0 and 4 h of IVC, the EDS group showed the best results at 63.8 and 46.6%, respectively, whereas the EP group showed the worst results at 42.2 and 12.8%, respectively. The apoptotic follicle ratio was lowest in the EDS group at 0 h (8.1%) and 0.5 h (12.7%) of IVC. All of the eight groups showed significant decreases in G1 follicles and increases in apoptotic follicles as IVC duration progressed. After autotransplantation, the EDS 0 h group showed a significantly higher G1 percentage (84.9%) than did the other groups (42.4-58.8%), while only the ES 4 h group showed a significant decrease in the number of proliferative cells (80.6%, 87.6-92.9%). However, no significant differences in apoptotic rates and FSH levels were observed between the groups after autotransplantation. The limitation of this study was the absence of in vitro fertilization using oocytes obtained from OT grafts, which should be performed to confirm the outcomes of ovarian cryopreservation and transplantation. We compared eight vitrification protocols according to CPA composition and found the EDS protocol to be the optimal method among them. The data presented herein will help improve OT cryopreservation protocols for humans or other animals.
Pathan, Arif H K; Barash, Alexander; Tena, Lawrence B; Finger, Paul T
2018-01-01
To provide a clinical description of the long-term outcome of a 103 Pd plaque-irradiated ciliary body melanoma with extrascleral extension while attempting to preserve a subadjacent glaucoma filtering bleb. A 75-year-old woman with pseudoexfoliative glaucoma for 17 years, 16 years status post argon laser trabeculoplasty, and 15 years status post trabeculectomy in the left eye, was diagnosed with an ipsilateral ciliary body melanoma with visible extrascleral extension. Treatment involved insertion of a 103 Pd radioactive plaque over the functioning trabeculectomy, with removal 7 days later. At plaque insertion, amniotic membrane grafts were used to cover the plaque and protect the filtering site. The tumor was successfully treated without clinical evidence of harm to the filtering bleb, with resultant stable intraocular pressure. However, the patient developed blebitis 1.5 years later. Though it resolved with topical antibiotic therapy, the bleb became less succulent. Two years postoperatively, she developed a spontaneous hyphema that resolved after one injection of transscleral bevacizumab 1.25 mg. Her tumor continually regressed in thickness. Without additional glaucoma surgery, her intraocular pressure remained well-controlled on topical medications for 6 years. Ciliary body melanoma with minimal extrascleral extension beneath a functioning filtering bleb can be treated using radioactive plaque therapy. In this case, we were able to achieve both tumor regression and glaucoma control by covering the plaque with an amniotic membrane graft.
USDA-ARS?s Scientific Manuscript database
Over 10,000 new mutants have been added to the UniformMu reverse genetics resource in release 7, bringing the total to over 67,000 germinal transposon insertions. These are available in 11,140 independent seed stocks. Close to half of the maize filtered gene set (42%) is represented by at least one ...
Camboni, A; Van Langendonckt, A; Donnez, J; Vanacker, J; Dolmans, M M; Amorim, C A
2013-08-01
One major concern of grafting cryopreserved ovarian tissue to restore fertility in cancer patients is the possibility of reintroducing tumor cells. Cryopreservation of isolated primordial/primary follicles (PFs) may circumvent this problem. The aim of our work was to compare dimethyl sulfoxide (ME2SO) and ethylene glycol (EG) as cryoprotectants (CPAs) for slow-freezing of isolated human PFs in alginate. Ovarian biopsies from four women were processed for follicle isolation. PFs were embedded in alginate (5-15 per group). Follicles were frozen-thawed using 1.4M ME2SO or 1.5M EG as CPAs. Fresh and cryopreserved isolated follicles were in vitro cultured (IVC) for 7 days. At different time periods (after isolation, cryopreservation and IVC), follicles were evaluated with live/dead assay (using fluorescent probes) and diameter measurement. Follicle viability was calculated according to the percentage of dead follicular cells and the presence of a live/dead oocyte. A total of 841 PFs were isolated, embedded in alginate and cryopreserved with ME2SO (n=424) or EG (n=259), or used as controls (n=158). After 7 days of IVC, a significant increase in follicle size was observed in the fresh and ME2SO groups, but not in the EG group. The percentage of totally viable PFs was not significantly different before or after seven days of culture in fresh (100% and 82%) or ME2SO (93.2% and 85.1%) tissue. The EG group showed significantly lower viability before (63.9%) and after IVC (66.2%) than the fresh and ME2SO groups. Our results show that 1.4M ME2SO yields better preservation of isolated PF viability after thawing and 7 days of IVC than 1.5M EG. Alginate constitutes an easy, safe hydrogel matrix to handle and cryopreserve isolated human follicles using ME2SO as a CPA. Copyright © 2013 Elsevier Inc. All rights reserved.
Towards Polarised Antiprotons: Machine Developments for Spin-Filtering Studies
NASA Astrophysics Data System (ADS)
Lenisa, Paolo
2016-02-01
We address the commissioning of the experimental equipment and the machine studies required for the first spin-filtering experiment with protons at the COSY ring in Jülich (Germany) at a beam kinetic energy of 49.3 MeV. The implementation of a low-beta insertion made it possible to achieve beam lifetimes of 8000 s in the presence of a dense polarized hydrogen storage cell target. The developed techniques can be directly applied to antiproton machines and allow for the determination of the spin-dependent pbar-p cross sections via spin-filtering.
Current US Military Operations and Implications for Military Surgical Training
2010-11-01
with most procedures encountered except nephrectomy (1.5 proce- dures per resident [PPR]), craniotomy (1.1 PPRs), inferior vena cava injury (1.1 PPRs... craniotomy , IVC injury, duodenal injury, and bladder re- pair. Residents had minimal experience with external fixa- tion of skeletal injury and...vascular injury 3.5 NR Nephrectomy 3.5 1.5 Pancreatic drainage 2.8 1.9 IVC injury 2.4 1.1 Duodenal injury 2.2 0.6 NR, procedure frequency not captured
NASA Astrophysics Data System (ADS)
Hariyadi, T.; Mulyasari, S.; Mukhidin
2018-02-01
In this paper we have designed and simulated a Band Pass Filter (BPF) at X-band frequency. This filter is designed for X-band weather radar application with 9500 MHz center frequency and bandwidth -3 dB is 120 MHz. The filter design was performed using a hairpin microstrip combined with an open stub and defected ground structure (DGS). The substrate used is Rogers RT5880 with a dielectric constant of 2.2 and a thickness of 1.575 mm. Based on the simulation results, it is found that the filter works on frequency 9,44 - 9,56 GHz with insertion loss value at pass band is -1,57 dB.
Histology of Tissue Adherent to OptEase Inferior Vena Cava Filters Regarding Indwelling Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Volkov, Alexander; Garniek, Alexander
The purpose of this paper is to report on the histology of tissues found on retrieved filters with regard to indwelling time. Between February 2006 and January 2007, 28 Optease inferior vena cava filters (Cordis Europa, Roden, The Netherlands) were retrieved from 27 patients. Twenty-two filters were inserted prophylactically for trauma patients and six for patients with venous thromboembolism. Cavography was performed both before and after filter removal to evaluate the presence of thrombi or wall damage. Filters were retrieved with the snare and sheath method. All material adherents to the filters were examined histologically.The mean indwelling time of themore » filters was 24.9 days (range, 6-69 days). Red tissue fragments were seen on all the filters, consistent microscopically with clots and fibrin. On five filters (18%; mean indwelling time, 45.4 days) white tissue consistent with vascular intima was found. All postprocedure cavographies were normal. We conclude that most material adherent to the retrieved filters is thrombi, while vascular intima can be found in the minority of filters with a longer indwelling time.« less
Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi
2014-09-01
To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.
Low-loss lateral-extensional piezoelectric filters on ultrananocrystalline diamond.
Fatemi, Hediyeh; Abdolvand, Reza
2013-09-01
In this work, lateral-extensional thin-film piezoelectric- on-diamond (TPoD) filters with very low insertion loss (IL) values (<4 dB) are reported. Two different lateral-extensional modes of a resonant structure are coupled together to realize a two-pole filter. The filters of this work exhibit low IL values, with fractional bandwidth between 0.08% and 0.2%, and have a very small footprint. This paper reports on the lowest IL in the literature for lateral-extensional thin-film piezoelectric filters with 50 Ω terminations in the GSM frequency band (~900 MHz). The narrow-band filters of this work are fabricated on three ultrananocrystalline diamond substrates to achieve higher frequencies without excessive reduction in the feature size. The paper also thoroughly studies the parameters that affect the performance of such filters and then discussions are evaluated by the statistical data collected from the fabricated wafers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.
1984-10-01
Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flowmore » or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery.« less
Bubb, Kathleen; du Plessis, Maira; Hage, Robert; Tubbs, R Shane; Loukas, Marios
2016-01-01
Major tributaries such as the renal and adrenal veins have been studied extensively; however, tributaries of the infra-renal segment of the inferior vena cava (IVC) have not been given much attention. Accurate knowledge of the anatomy of these veins is necessary for improved efficacy of surgical interventions in the retroperitoneum. The aim of this study therefore was to provide a comprehensive picture of the internal anatomy of the tributaries of the infra-renal segment of the IVC. Dissection of the posterior abdominal wall was performed on 30 formalin-fixed cadavers. Endoscopic study was carried out followed by a midline venotomy on the anterior wall of the isolated IVC, the location and orientation of its tributaries and their ostia were observed and measurements taken. The results showed that while there was great variation in the drainage pattern of the lumbar veins, most lumbar veins had ostia located between L2 and L3 vertebrae irrespective of the location of renal and gonadal tributaries. Valves were found in 81.81 % of gonadal veins, in 56.60 % of all lumbar veins and discrete ostial valves in 14.81 % of renal veins. The location of the tributaries of the IVC was correlated with the vertebral levels. Empirical data regarding their ostio-valvular complexes were established, which put into question widely accepted concept of valveless tributaries. Our results may implicate surgical procedures in and around the retroperitoneal region.
Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel
2018-02-23
Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.
Intelligent viewing control for robotic and automation systems
NASA Astrophysics Data System (ADS)
Schenker, Paul S.; Peters, Stephen F.; Paljug, Eric D.; Kim, Won S.
1994-10-01
We present a new system for supervisory automated control of multiple remote cameras. Our primary purpose in developing this system has been to provide capability for knowledge- based, `hands-off' viewing during execution of teleoperation/telerobotic tasks. The reported technology has broader applicability to remote surveillance, telescience observation, automated manufacturing workcells, etc. We refer to this new capability as `Intelligent Viewing Control (IVC),' distinguishing it from a simple programmed camera motion control. In the IVC system, camera viewing assignment, sequencing, positioning, panning, and parameter adjustment (zoom, focus, aperture, etc.) are invoked and interactively executed by real-time by a knowledge-based controller, drawing on a priori known task models and constraints, including operator preferences. This multi-camera control is integrated with a real-time, high-fidelity 3D graphics simulation, which is correctly calibrated in perspective to the actual cameras and their platform kinematics (translation/pan-tilt). Such merged graphics- with-video design allows the system user to preview and modify the planned (`choreographed') viewing sequences. Further, during actual task execution, the system operator has available both the resulting optimized video sequence, as well as supplementary graphics views from arbitrary perspectives. IVC, including operator-interactive designation of robot task actions, is presented to the user as a well-integrated video-graphic single screen user interface allowing easy access to all relevant telerobot communication/command/control resources. We describe and show pictorial results of a preliminary IVC system implementation for telerobotic servicing of a satellite.
Azoulay, Daniel; Andreani, Paola; Maggi, Umberto; Salloum, Chadi; Perdigao, Fabiano; Sebagh, Mylène; Lemoine, Antoinette; Adam, René; Castaing, Denis
2006-07-01
Liver tumors with inferior vena cava (IVC) involvement may require combined resection of the liver and IVC. This approach, with its high surgical risks and poor long-term prognosis, was precluded until the development of neoadjuvant chemotherapy, portal vein embolization, reinforced vascular prostheses, and technical advances in liver transplantation. We reviewed 22 cases of hepatectomy with retrohepatic IVC resection and reconstruction. The patients had a median age of 51.5 years (range, 32.8-75.3 years). Indications for resection were: liver metastases (n = 9), cholangiocarcinoma (n = 8), hepatocellular carcinoma (n = 2), other cancers (n = 3). The liver resections carried out included 18 first, 3 second, and one third hepatectomy. Segment 1 (caudate lobe) was included in the specimen in 19 cases (86%). Resection concerned 1 to 6 liver segments (median = 5.0). Vascular control was achieved by vascular exclusion of the liver preserving the caval flow (n = 1), standard vascular exclusion of the liver (n = 12), in situ cold perfusion of the liver (n = 9). Ex situ surgery was not necessary in any case. Venovenous bypass was used in 12 cases. The IVC was reconstructed with a ringed Gore-Tex tube graft (n = 10), primarily (n = 8), or by caval plasty (n = 4). A main hepatic vein was reimplanted in 6 cases: into the native IVC (n = 4) or into a Gore-Tex tube graft (n = 2). One patient died (4.5%) due to catheter infection, 7 days after in situ cold perfusion with replacement of the vena cava. Eight patients (36%) had no complications and 14 patients (64%) had 23 complications. In all but 1 case, the complications were transient and successfully controlled. The patients stayed in intensive care for 3.3 +/- 2.0 days and in the hospital for 17.7 +/- 7.8 days. All vascular reconstructions were patent at last follow-up. With median follow-up of 19 months, 10 patients died of tumor recurrence and eleven were alive with (n = 5) or without (n = 6) disease. Actuarial 1-, 3-, and 5-year survival rates were 81.8%, 38.3%, and 38.3%, respectively. IVC resection and reconstruction combined with liver resection can be safely performed in selected patients. The lack of alternative treatments and the spontaneous poor prognosis justify this approach, provided that surgery is carried out at a center specialized in both liver surgery and liver transplantation. The development of adjuvant chemotherapy regimens is required to improve the long-term results of this salvage surgery.
Transoral Robotic Surgery in Treating Patients With Benign or Malignant Tumors of the Head and Neck
2018-06-26
Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage 0 Hypopharyngeal Cancer; Stage 0 Laryngeal Cancer; Stage 0 Lip and Oral Cavity Cancer; Stage I Adenoid Cystic Carcinoma of the Oral Cavity; Stage I Mucoepidermoid Carcinoma of the Oral Cavity; Stage I Squamous Cell Carcinoma of the Hypopharynx; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Adenoid Cystic Carcinoma of the Oral Cavity; Stage II Mucoepidermoid Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Hypopharynx; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Adenoid Cystic Carcinoma of the Oral Cavity; Stage III Mucoepidermoid Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
Performance of a high T (sub c) superconducting ultra-low loss microwave stripline filter
NASA Technical Reports Server (NTRS)
Bautista, J. J.; Ortiz, G.; Zahopoulos, C.; Sridhar, S.; Lanagan, M.
1991-01-01
Discussed here is the successful fabrication of a five-pole interdigital stripline filter made of the 93 K superconductor (Y1Ba2Cu3O sub y) coated on a silver substrate, with center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest injection loss measured was 0.1 dB at 12 K, with a return loss of better than 16 dB, representing a significant improvement over a similar copper filter, and is comparable to low critical temperature filters. The insertion loss appears to be limited by extrinsic factors, such as tuning mismatch and joint losses, and not by superconducting material losses.
Design optimization of integrated BiDi triplexer optical filter based on planar lightwave circuit.
Xu, Chenglin; Hong, Xiaobin; Huang, Wei-Ping
2006-05-29
Design optimization of a novel integrated bi-directional (BiDi) triplexer filter based on planar lightwave circuit (PLC) for fiber-to-the premise (FTTP) applications is described. A multi-mode interference (MMI) device is used to filter the up-stream 1310nm signal from the down-stream 1490nm and 1555nm signals. An array waveguide grating (AWG) device performs the dense WDM function by further separating the two down-stream signals. The MMI and AWG are built on the same substrate with monolithic integration. The design is validated by simulation, which shows excellent performance in terms of filter spectral characteristics (e.g., bandwidth, cross-talk, etc.) as well as insertion loss.
Design optimization of integrated BiDi triplexer optical filter based on planar lightwave circuit
NASA Astrophysics Data System (ADS)
Xu, Chenglin; Hong, Xiaobin; Huang, Wei-Ping
2006-05-01
Design optimization of a novel integrated bi-directional (BiDi) triplexer filter based on planar lightwave circuit (PLC) for fiber-to-the premise (FTTP) applications is described. A multi-mode interference (MMI) device is used to filter the up-stream 1310nm signal from the down-stream 1490nm and 1555nm signals. An array waveguide grating (AWG) device performs the dense WDM function by further separating the two down-stream signals. The MMI and AWG are built on the same substrate with monolithic integration. The design is validated by simulation, which shows excellent performance in terms of filter spectral characteristics (e.g., bandwidth, cross-talk, etc.) as well as insertion loss.
A wideband superconducting filter at Ku-band based on interdigital coupling
NASA Astrophysics Data System (ADS)
Jiang, Ying; Wei, Bin; Cao, Bisong; Li, Qirong; Guo, Xubo; Jiang, Linan; Song, Xiaoke; Wang, Xiang
2018-04-01
In this paper, an interdigital-type resonator with strong electric coupling is proposed for the wideband high-frequency (>10 GHz) filter design. The proposed microstrip resonator consists of an H-shaped main line part with its both ends installed with interdigital finger parts. Strong electric coupling is achieved between adjacent resonators. A six-pole high-temperature superconducting filter at Ku-band using this resonator is designed and fabricated. The filter has a center frequency of 15.11 GHz with a fractional bandwidth of 30%. The insertion loss of the passband is less than 0.3 dB, and the return loss is greater than 14 dB without any tuning.
21 CFR 886.1800 - Schirmer strip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device made of filter paper or similar material intended to be inserted under a patient's lower eyelid to stimulate and evaluate formation of tears. (b) Classification. Class I (general controls). If the device is...
NASA Technical Reports Server (NTRS)
Subramanyam, Guru; Vignesparamoorthy, Sivaruban; Mueller, Carl; VanKeuls, Fred; Warner, Joseph; Miranda, Felix A.
2001-01-01
The main purpose of this work is to study the effect of a selectively etched ferroelectric thin film layer on the performance of an electrically tunable filter. An X-band tunable filter was designed, fabricated and tested on a selectively etched Barium Strontium Titanate (BSTO) ferroelectric thin film layer. Tunable filters with varying lengths of BSTO thin-film in the input and output coupling gaps were modeled, as well as experimentally tested. Experimental results showed that filters with coupling gaps partially filled with BSTO maintained frequency tunability and improved the insertion loss by approx. 2dB. To the best of our knowledge, these results represent the first experimental demonstration of the advantages of selective etching in the performance of thin film ferroelectric-based tunable microwave components.
Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-03-16
A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.
Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-01-01
Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679
2018-04-18
BRAF Gene Mutation; Poorly Differentiated Thyroid Gland Carcinoma; RAS Family Gene Mutation; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7
Individualized treatment in stage IVC nasopharyngeal carcinoma.
Chan, Oscar S H; Ngan, Roger K C
2014-09-01
The stage IVC nasopharyngeal carcinoma is a catch-all entity covering minute solitary metastasis to bulky disseminated disease. Prognosis varies greatly within this stage group. A subset of patients with oligometastases may benefit from aggressive local ablative therapy. Meanwhile, in multiple metastatic diseases, customizing conventional cytotoxics basing on individual tumor characteristics and previous chemotherapy responses can be a new direction to improve therapeutic results. Prognostic models built on clinical features and genomic profiles can be utilized to stratify different risk groups and tailor therapy schemes. Copyright © 2014 Elsevier Ltd. All rights reserved.
2017-07-11
Stage 0 Nasopharyngeal Carcinoma; Stage 0 Paranasal Sinus Cancer; Stage I Nasopharyngeal Carcinoma; Stage I Paranasal Sinus Cancer; Stage II Nasopharyngeal Carcinoma; Stage II Paranasal Sinus Cancer; Stage IIA Nasopharyngeal Carcinoma; Stage IIB Nasopharyngeal Carcinoma; Stage III Nasopharyngeal Carcinoma; Stage III Paranasal Sinus Cancer; Stage IV Nasopharyngeal Carcinoma; Stage IV Paranasal Sinus Cancer; Stage IVA Nasopharyngeal Carcinoma; Stage IVA Paranasal Sinus Cancer; Stage IVB Nasopharyngeal Carcinoma; Stage IVB Paranasal Sinus Cancer; Stage IVC Nasopharyngeal Carcinoma; Stage IVC Paranasal Sinus Cancer
2018-03-21
Recurrent Oral Cavity Adenoid Cystic Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Adenoid Cystic Carcinoma; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7
Microwave Bandpass Filter Based on Mie-Resonance Extraordinary Transmission
Pan, Xiaolong; Wang, Haiyan; Zhang, Dezhao; Xun, Shuang; Ouyang, Mengzhu; Fan, Wentao; Guo, Yunsheng; Wu, Ye; Huang, Shanguo; Bi, Ke; Lei, Ming
2016-01-01
Microwave bandpass filter structure has been designed and fabricated by filling the periodically metallic apertures with dielectric particles. The microwave cannot transmit through the metallic subwavelength apertures. By filling the metallic apertures with dielectric particles, a transmission passband with insertion loss 2 dB appears at the frequency of 10–12 GHz. Both simulated and experimental results show that the passband is induced by the Mie resonance of the dielectric particles. In addition, the passband frequency can be tuned by the size and the permittivity of the dielectric particles. This approach is suitable to fabricate the microwave bandpass filters. PMID:27992440
A Dual Mode BPF with Improved Spurious Response Using DGS Cells Embedded on the Ground Plane of CPW
NASA Astrophysics Data System (ADS)
Weng, Min-Hang; Ye, Chang-Sin; Hung, Cheng-Yuan; Huang, Chun-Yueh
A novel dual mode bandpass filter (BPF) with improved spurious response is presented in this letter. To obtain low insertion loss, the coupling structure using the dual mode resonator and the feeding scheme using coplanar-waveguide (CPW) are constructed on the two sides of a dielectric substrate. A defected ground structure (DGS) is designed on the ground plane of the CPW to achieve the goal of spurious suppression of the filter. The filter has been investigated numerically and experimentally. Measured results show a good agreement with the simulated analysis.
Kadota, Michio; Tanaka, Shuji
2015-05-01
A cognitive radio terminal using vacant frequency bands of digital TV (DTV) channels, i.e., TV white space, strongly requires a compact tunable filter covering a wide frequency range of the DTV band (470 to 710 MHz in Japan). In this study, a T-type ladder filter using ultra-wideband shear horizontal mode plate wave resonators was fabricated, and a low peak insertion loss of 0.8 dB and an ultra-large 6 dB bandwidth of 240 MHz (41%) were measured in the DTV band. In addition, bandpass filters with different center frequencies of 502 and 653 MHz at 6 dB attenuation were numerically synthesized based on the same T-type ladder filter in conjunction with band rejection filters with different frequencies. The results suggest that the combination of the wideband T-type ladder filter and the band rejection filters connected with variable capacitors enables a tunable filter with large tunability of frequency and bandwidth as well as large rejection at the adjacent channels of an available TV white space.
Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M
2006-01-01
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wildberger, Joachim Ernst, E-mail: wildberg@rad.rwth-aachen.de; Haage, Patrick; Bovelander, Jan
2005-04-15
Purpose. To evaluate the size and quantity of downstream emboli after thrombectomy using the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with or without temporary filtration for extensive iliofemoral and iliocaval thrombi in an in vitro flow model. Methods. Iliocaval thrombi were simulated by clotted bovine blood in a flow model (semilucent silicone tubings, diameter 12-16 mm). Five experimental set-ups were performed 10 times each; thrombus particles and distribution were measured in the effluent. First, after retrograde insertion, mechanical thrombectomy was performed using the PTD alone. Then a modified self-expanding tulip-shaped temporary vena cava stent filter was inserted additionally at the beginningmore » of each declotting procedure and removed immediately after the intervention without any manipulation within or at the filter itself. In a third step, the filter was filled with thrombus only. Here, two experiments were performed: Careful closure within the flow circuit without any additional fragmentation procedure and running the PTD within the filter lumen, respectively. In the final set-up, mechanical thrombectomy was performed within the thrombus-filled tubing as well as in the filter lumen. The latter was closed at the end of the procedure and both devices were removed from the flow circuit. Results. Running the PTD in the flow circuit without filter protection led to a fragmentation of 67.9% ({+-}7.14%) of the clot into particles {<=}500 {mu}m; restoration of flow was established in all cases. Additional placement of the filter safely allowed maceration of 82.9% ({+-}5.59%) of the thrombus. Controlled closure of the thrombus-filled filter within the flow circuit without additional mechanical treatment broke up 75.2% ({+-}10.49%), while additional mechanical thrombectomy by running the PTD within the occluded filter led to dissolution of 90.4% ({+-}3.99%) of the initial clot. In the final set-up, an overall fragmentation rate of 99.6% ({+-}0.44%) was achieved. Conclusions. The combined use of the Arrow-Trerotola PTD and a temporary vena cava stent filter proved to be effective for even large clot removal in this experimental set-up.« less
Pasquarelli, Noemi; Voehringer, Patrizia; Henke, Julia; Ferger, Boris
2017-08-30
The development of modern housing regimes such as individually ventilated cage (IVC) systems has become very popular and attractive in order to reduce spreading of pathogenic organisms and to lower the risk to develop a laboratory animal allergy for staff members. Additionally, optimal housing of laboratory animals contributes to improve animal health status and ensures high and comparable experimental and animal welfare standards. However, it has not been clearly elucidated whether 1) a change to IVC systems have an impact on various physiological phenotypic parameters of mice when compared to conventional, standard cages and 2) if this is further affected by changing from social to single housing. Therefore, we investigated the influence of a change in housing conditions (standard cages with social housing changed to standard or IVC cages combined with social or single housing) on body weight, behavior and a neurochemical fingerprint of male C57BL/6J mice. Body weight progression was significantly reduced when changing mice to single or social IVC cages as well as in single standard cages when compared to social standard housing. Automated motor activity measurement in the open field showed that mice maintained in social husbandry with standard cages displayed the lowest exploratory behavior but the highest activity difference upon amphetamine treatment. Elevated plus maze test revealed that a change to IVC single and social housing as well as single standard housing produced anxiety-related behavior when compared to maintenance in social standard housing. Additionally, postmortem neurochemical analysis of the striatum using high-performance liquid chromatography coupled to electrochemical detection showed significant differences in striatal dopamine and serotonin turnover levels. In summary, our data indicate a crucial influence of a change in housing conditions on several mouse phenotype parameters. We propose that the maintenance of well-defined housing conditions is mandatory to ensure reproducible and comparable results and contributes to the application of the 3R refinement principle in animal studies by contributing to welfare and hygienical standards. Copyright © 2017 Elsevier B.V. All rights reserved.
Sebastian, Tim; Dopheide, Jörn F; Engelberger, Rolf P; Spirk, David; Kucher, Nils
2018-05-01
Occlusion of the inferior vena cava (IVC) often causes venous claudication, leg swelling, or skin changes. We hypothesized that the outcome of nitinol stents for endovascular reconstruction of the IVC is similar to the outcome reported for steel alloy stents. From the prospective Bern Venous Stent Registry, we investigated technical success, patency rates, and clinical outcome in consecutive patients with endovascular IVC reconstruction. During routine follow-up visits, stent patency was assessed by duplex ultrasound. Clinical outcomes were evaluated using the Bozkaya score, Villalta score, and revised Venous Clinical Severity Score. Of the 62 patients (mean age, 46 ± 18 years), 33 (53%) patients were treated for the post-thrombotic syndrome, 17 (27%) for acute thrombosis, and 12 (19%) for nonthrombotic IVC occlusion. Technical success was achieved in 61 (98%) patients, with a mean of 4.5 ± 1.9 stents (iliac kissing stents in 84%). During follow-up (mean, 21 months), 22 (36%) underwent endovascular reintervention for symptomatic stent stenosis (13 [21%] with complete stent occlusion). Primary, primary assisted, and secondary patency rates at 24 months were 57% (95% confidence interval [CI], 50%-73%), 76% (95% CI, 65%-86%), and 87% (95% CI, 80%-95%), respectively. None developed new ulcers, and all eight patients with venous ulcers at baseline had complete healing. Twenty-nine (48%) patients showed significant clinical improvement, and another 26 (43%) were free from any symptoms or signs of venous hypertension. Patients with post-thrombotic venographic changes of the femoral veins at baseline or a history of thrombosis were more likely to lose primary patency compared with patients with normal leg inflow veins and no history of thrombosis (19 [48%] vs 3 [16%]; P = .02). The clinical outcome of endovascular reconstruction of the IVC with nitinol stents was favorable. However, approximately one-third of the patients required reintervention to maintain stent patency, most likely because of the impaired venous inflow. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Illuminati, Giulio; Calio, Francesco G; Angelici, Alberto M; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Vietri, Francesco
2016-07-01
Optimal treatment strategy for retroperitoneal recurrence of testicular cancer involving the inferior vena cava (IVC) is uncertain. The purpose of this study was to validate the hypothesis that surgical resection, en-bloc with the involved segment of IVC and its subsequent reconstruction followed by chemotherapy, would yield better oncologic results than chemotherapy alone. Two consecutive series of patients with retroperitoneal recurrence of testicular cancer involving the IVC, treated with surgical resection plus chemotherapy (group A, n=14) or chemotherapy alone (group B, n=8) were retrospectively reviewed. The mean duration of follow-up was was 65 months (range=8-184). Operative mortality and morbidity in group A, response to chemotherapy in group B, disease-specific survival and quality adjusted life-years (QALY) for both groups, were primary end-points of the study. Postoperative mortality and morbidity (group A) were, respectively, nil and 14%. In group B, two patients (25%) fully responded to chemotherapy and remained free from disease progression. Disease-specific survival at 3 and 5 years was 81% and 54% in group A and 36% in group B both at 3 and 5 years, respectively (p=0.02). QALY was 3.92 in group A and 0.77 for both 3 and 5 years in group B, respectively, (p=0.031). En bloc resection of retroperitoneal recurrence of testicular tumors invading the IVC, followed by chemotherapy, allows a better survival rate compared to chemotherapy alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Evaluating MRI based vascular wall motion as a biomarker of Fontan hemodynamic performance
NASA Astrophysics Data System (ADS)
Menon, Prahlad G.; Hong, Haifa
2015-03-01
The Fontan procedure for single-ventricle heart disease involves creation of pathways to divert venous blood from the superior & inferior venacavae (SVC, IVC) directly into the pulmonary arteries (PA), bypassing the right ventricle. For optimal surgical outcomes, venous flow energy loss in the resulting vascular construction must be minimized and ensuring close to equal flow distribution from the Fontan conduit connecting IVC to the left & right PA is paramount. This requires patient-specific hemodynamic evaluation using computational fluid dynamics (CFD) simulations which are often time and resource intensive, limiting applicability for real-time patient management in the clinic. In this study, we report preliminary efforts at identifying a new non-invasive imaging based surrogate for CFD simulated hemodynamics. We establish correlations between computed hemodynamic criteria from CFD modeling and cumulative wall displacement characteristics of the Fontan conduit quantified from cine cardiovascular MRI segmentations over time (i.e. 20 cardiac phases gated from the start of ventricular systole), in 5 unique Fontan surgical connections. To focus our attention on diameter variations while discounting side-to-side swaying motion of the Fontan conduit, the difference between its instantaneous regional expansion and inward contraction (averaged across the conduit) was computed and analyzed. Maximum Fontan conduit-average expansion over the cardiac cycle correlated with the anatomy-specific diametric offset between the axis of the IVC and SVC (r2=0.13, p=0.55) - a known factor correlated with Fontan energy loss and IVC-to-PA flow distribution. Investigation in a larger study cohort is needed to establish stronger statistical correlations.
Distension of central great vein decreases sympathetic outflow in humans
Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D.; Mast, Jessica
2013-01-01
Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ∼27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans. PMID:23729210
Distension of central great vein decreases sympathetic outflow in humans.
Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D; Mast, Jessica; Sinoway, Lawrence I
2013-08-01
Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ~27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans.
Preliminary design of the spatial filters used in the multipass amplification system of TIL
NASA Astrophysics Data System (ADS)
Zhu, Qihua; Zhang, Xiao Min; Jing, Feng
1998-12-01
The spatial filters are used in Technique Integration Line, which has a multi-pass amplifier, not only to suppress parasitic high spatial frequency modes but also to provide places for inserting a light isolator and injecting the seed beam, and to relay image while the beam passes through the amplifiers several times. To fulfill these functions, the parameters of the spatial filters are optimized by calculations and analyzes with the consideration of avoiding the plasma blow-off effect and components demanding by ghost beam focus. The 'ghost beams' are calculated by ray tracing. A software was developed to evaluate the tolerance of the spatial filters and their components, and to align the whole system on computer simultaneously.
2018-03-04
Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
Wiebe, Jens; Rixe, Johannes; Nef, Holger
2015-10-01
A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.
Lab-on-a-chip in vitro compartmentalization technologies for protein studies.
Zhu, Yonggang; Power, Barbara E
2008-01-01
In vitro compartmentalization (IVC) is a powerful tool for studying protein-protein reactions, due to its high capacity and the versatility of droplet technologies. IVC bridges the gap between chemistry and biology as it enables the incorporation of unnatural amino acids with modifications into biological systems, through protein transcription and translation reactions, in a cell-like microdrop environment. The quest for the ultimate chip for protein studies using IVC is the drive for the development of various microfluidic droplet technologies to enable these unusual biochemical reactions to occur. These techniques have been shown to generate precise microdrops with a controlled size. Various chemical and physical phenomena have been utilized for on-chip manipulation to allow the droplets to be generated, fused, and split. Coupled with detection techniques, droplets can be sorted and selected. These capabilities allow directed protein evolution to be carried out on a microchip. With further technological development of the detection module, factors such as addressable storage, transport and interfacing technologies, could be integrated and thus provide platforms for protein studies with high efficiency and accuracy that conventional laboratories cannot achieve.
Chen, Chen; Gao, George F.
2012-01-01
A growing number of pathogens are being found to possess specialized secretion systems which they use in various ways to subvert host defenses. Type IV secretion system (T4SS) is one of versatile secretion systems essential for the virulence and even survival of some bacteria species, and they enable the secretion of protein and DNA substrates across the cell envelope. T4SS was once believed to be present only in Gram-negative bacteria. In this study, we present evidence of a new subclass of T4SS, Type-IVC secretion system and indicate its common existence in the Gram-positive bacterial genus Streptococcus. We further identified that VirB1, VirB4, VirB6 and VirD4 are the minimal key components of this system. Using genome comparisons and evolutionary relationship analysis, we proposed that Type-IVC secretion system is movable via transposon factors and mediates the conjugative transfer of DNA, enhances bacterial pathogenicity, and could cause large-scale outbreaks of infections in humans. PMID:23056296
1984-06-26
case may be, in excess of 80 percent. They are multilayer coatings made by Optical Coating Laboratories, Inc., specifically for this application. The...series of measurements were made using each pinhole without the broadband filter. Then, the filters were inserted into the collimator source optics...between the primary mirror and the aperture wheel pinholes. Mea- surements were made at three (’VI positions corresponding to wavelengths cen- t(ered at
Is ultraviolet radiation on haemodialysis RO water beneficial?
Stragier, A
2005-01-01
The quality of dialysis fluids has become increasingly important in the treatment of HD patients. Purified water represents over 95% of its volume. Bacterial and endotoxin content of Reverse Osmosis (RO) water is usually kept under control by bacterial filters, inserted in the distribution departure loop, and by monthly disinfection of the distribution circuit; the simpler the circuit, the better. This paper reports 12 years experience during which Ultraviolet Irradiation (UV) has replaced bacterial filters. To keep the bacterial growth under control in a complex RO water circuit (including a tank and multiple loops) a simple UV lamp was inserted in the departure line. It proved sufficient to keep bacterial count within AAMI norms. Failure of the UV lamp was associated with a rise of up to 500 cfu/ml in the last (fourth week) before routine disinfection. Normal levels were again obtained after replacement of the UV lamp. Six years later, a second UV lamp was added on the return loop. Bacterial counts and endotoxin levels in RO water promptly fell to <1 cfu/ml and <0.125 EU, till today. It is concluded that UV lamps should be favoured over bacterial filters in systems that are not disinfected daily, such as the RO water circuit. The principle of UV irradiation is explained and its advantage over bacterial filters is discussed. Future possible applications of UV are presented.
SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitcham, T; Bouchard, R; Melancon, A
Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic amore » human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.« less
Phase 1b Food Based Modulation of Biomarkers in Human Tissues at High-Risk for Oral Cancer.
2018-03-05
Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage 0 Hypopharyngeal Cancer; Stage 0 Laryngeal Cancer; Stage 0 Lip and Oral Cavity Cancer; Stage 0 Nasopharyngeal Cancer; Stage 0 Oropharyngeal Cancer; Stage 0 Paranasal Sinus and Nasal Cavity Cancer; Stage I Salivary Gland Cancer; Stage I Squamous Cell Carcinoma of the Hypopharynx; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Nasopharynx; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Salivary Gland Cancer; Stage II Squamous Cell Carcinoma of the Hypopharynx; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Nasopharynx; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Oral Cavity Squamous Cell Carcinoma; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Nasal Cavity and Paranasal Sinus Cancer; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Oral Cavity Squamous Cell Carcinoma; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Oral Cavity Squamous Cell Carcinoma; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Paranasal Sinus and Nasal Cavity Squamous Cell Carcinoma; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer
UWB Filtering Power Divider with Two Narrow Notch-bands and Wide Stop-band
NASA Astrophysics Data System (ADS)
Wei, Feng; Wang, Xin-Yi; Zou, Xin Tong; Shi, Xiao Wei
2017-12-01
A compact filtering ultra-wideband (UWB) microstrip power divider (PD) with two sharply rejected notch-bands and wide stopband is analyzed and designed in this paper. The proposed UWB PD is based on a conventional Wilkinson power divider, while two stub loaded resonators (SLRs) are coupled into two symmetrical output ports to achieve a bandpass filtering response. The simplified composite right/left-handed (SCRLH) resonators are employed to generate the dual notched bands. Defected ground structure (DGS) is introduced to improve the passband performance. Good insertion/return losses, isolation and notch-band rejection are achieved as demonstrated in both simulation and experiment.
Horst, Folkert; Green, William M J; Assefa, Solomon; Shank, Steven M; Vlasov, Yurii A; Offrein, Bert Jan
2013-05-20
We present 1-to-8 wavelength (de-)multiplexer devices based on a binary tree of cascaded Mach-Zehnder-like lattice filters, and manufactured using a 90 nm CMOS-integrated silicon photonics technology. We demonstrate that these devices combine a flat pass-band over more than 50% of the channel spacing with low insertion loss of less than 1.6 dB, and have a small device size of approximately 500 × 400 µm. This makes this type of filters well suited for application as WDM (de-)multiplexer in silicon photonics transceivers for optical data communication in large scale computer systems.
Toward polarized antiprotons: Machine development for spin-filtering experiments
NASA Astrophysics Data System (ADS)
Weidemann, C.; Rathmann, F.; Stein, H. J.; Lorentz, B.; Bagdasarian, Z.; Barion, L.; Barsov, S.; Bechstedt, U.; Bertelli, S.; Chiladze, D.; Ciullo, G.; Contalbrigo, M.; Dymov, S.; Engels, R.; Gaisser, M.; Gebel, R.; Goslawski, P.; Grigoriev, K.; Guidoboni, G.; Kacharava, A.; Kamerdzhiev, V.; Khoukaz, A.; Kulikov, A.; Lehrach, A.; Lenisa, P.; Lomidze, N.; Macharashvili, G.; Maier, R.; Martin, S.; Mchedlishvili, D.; Meyer, H. O.; Merzliakov, S.; Mielke, M.; Mikirtychiants, M.; Mikirtychiants, S.; Nass, A.; Nikolaev, N. N.; Oellers, D.; Papenbrock, M.; Pesce, A.; Prasuhn, D.; Retzlaff, M.; Schleichert, R.; Schröer, D.; Seyfarth, H.; Soltner, H.; Statera, M.; Steffens, E.; Stockhorst, H.; Ströher, H.; Tabidze, M.; Tagliente, G.; Engblom, P. Thörngren; Trusov, S.; Valdau, Yu.; Vasiliev, A.; Wüstner, P.
2015-02-01
The paper describes the commissioning of the experimental equipment and the machine studies required for the first spin-filtering experiment with protons at a beam kinetic energy of 49.3 MeV in COSY. The implementation of a low-β insertion made it possible to achieve beam lifetimes of τb=8000 s in the presence of a dense polarized hydrogen storage-cell target of areal density dt=(5.5 ±0.2 )×1 013 atoms /cm2 . The developed techniques can be directly applied to antiproton machines and allow the determination of the spin-dependent p ¯p cross sections via spin filtering.
Development and comparison of projection and image space 3D nodule insertion techniques
NASA Astrophysics Data System (ADS)
Robins, Marthony; Solomon, Justin; Sahbaee, Pooyan; Samei, Ehsan
2016-04-01
This study aimed to develop and compare two methods of inserting computerized virtual lesions into CT datasets. 24 physical (synthetic) nodules of three sizes and four morphologies were inserted into an anthropomorphic chest phantom (LUNGMAN, KYOTO KAGAKU). The phantom was scanned (Somatom Definition Flash, Siemens Healthcare) with and without nodules present, and images were reconstructed with filtered back projection and iterative reconstruction (SAFIRE) at 0.6 mm slice thickness using a standard thoracic CT protocol at multiple dose settings. Virtual 3D CAD models based on the physical nodules were virtually inserted (accounting for the system MTF) into the nodule-free CT data using two techniques. These techniques include projection-based and image-based insertion. Nodule volumes were estimated using a commercial segmentation tool (iNtuition, TeraRecon, Inc.). Differences were tested using paired t-tests and R2 goodness of fit between the virtually and physically inserted nodules. Both insertion techniques resulted in nodule volumes very similar to the real nodules (<3% difference) and in most cases the differences were not statistically significant. Also, R2 values were all <0.97 for both insertion techniques. These data imply that these techniques can confidently be used as a means of inserting virtual nodules in CT datasets. These techniques can be instrumental in building hybrid CT datasets composed of patient images with virtually inserted nodules.
Single Center Experience with the AngioVac Aspiration System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salsamendi, Jason, E-mail: jsalsamendi@med.miami.edu; Doshi, Mehul, E-mail: mdoshi@med.miami.edu; Bhatia, Shivank, E-mail: sbhatia1@med.miami.edu
2015-08-15
PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and themore » patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.« less
Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan
2017-12-01
The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Shan; Cui, Liyong; Liu, Fen
We have theoretically investigated the electronic resonant tunneling effect in graphene superlattice heterostructures, where a tunable graphene layer is inserted between two different superlattices. It is found that a complete tunneling state appears inside the enlarged forbidden gap of the heterostructure by changing the thickness of the inserted graphene layer and the transmittance of the tunneling state depends on the thickness of the inserted layer. Furthermore, the frequency of the tunneling state changes with the thickness of the inserted graphene layer but it always located in the little overlapped forbidden gap of two graphene superlattices. Therefore, both a perfect tunnelingmore » state and an ultrawide forbidden gap are realized in such heterostrutures. Since maximum probability densities of the perfect tunneling state are highly localized near the interface between the inserted graphene layer and one graphene superlattice, it can be named as an interface-like state. Such structures are important to fabricate high-Q narrowband electron wave filters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin
PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission ratemore » and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.« less
Imaging Analysis of Hepatoblastoma Resectability Across Neoadjuvant Chemotherapy
Murphy, Andrew J.; Ayers, Gregory D.; Hilmes, Melissa A.; Mukherjee, Kaushik; Wilson, Kevin J.; Allen, Wade M.; Fernandez-Pineda, Israel; Shinall, Myrick C.; Zhao, Zhiguo; Furman, Wayne L.; McCarville, Mary Beth; Davidoff, Andrew M.; Lovvorn, Harold N.
2013-01-01
Purpose Hepatoblastomas often require neoadjuvant chemotherapy to facilitate partial hepatectomy, which necessitates freedom of tumor borders from the confluence of hepatic veins (COHV), portal vein bifurcation (PVB), and retrohepatic inferior vena cava (IVC). This study aimed to clarify the effect of incremental neoadjuvant cycles on the AHEP0731 protocol criteria of hepatoblastoma resectability. Methods Hepatoblastoma responses to neoadjuvant chemotherapy were analyzed among patients (n=23) treated at two children’s hospitals between 1996 and 2010. Using digital imaging data, ellipsoid and point-based models were created to measure tumor volume regression and respective distances from tumor borders nearest to the COHV, PVB, and IVC. Results Hepatoblastoma volumes regressed with incremental neoadjuvant chemotherapy cycles (p<0.001). Although tumor borders regressed away from the COHV (p=0.008), on average only 1.1mm was gained. No change from tumor borders to the PVB was detected (p=0.102). Distances from tumor borders to the IVC remained stable at one hospital (p=0.612), but increased only 0.15mm every 10 days of therapy at the other (p=0.002). Neoadjuvant chemotherapy induced slightly more tumors to meet the threshold vascular margin of 1cm (baseline to completion): COHV, 11 (47.8%) to 17 (73.9%; p=0.058); PVB, 11 (47.8%) to 15 (65.2%; p=0.157); IVC, 4 (17.4%) to 10 (43.5%; p=0.034). No differences were detected in demographic or disease-specific characteristics between patients who did or did not achieve this 1cm margin after conclusion of chemotherapy. Conclusion Hepatoblastoma volumes regress significantly with increasing neoadjuvant chemotherapy cycles. However, tumors often remain anchored to the major hepatic vasculature, showing marginal improvement in resectability criteria. PMID:23845613
Modification and performance evaluation of a mono-valve engine
NASA Astrophysics Data System (ADS)
Behrens, Justin W.
A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.
Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus
2017-06-01
One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.
Jarvis, Kelly; Schnell, Susanne; Barker, Alex J.; Garcia, Julio; Lorenz, Ramona; Rose, Michael; Chowdhary, Varun; Carr, James; Robinson, Joshua D.; Rigsby, Cynthia K.; Markl, Michael
2016-01-01
Background Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. Objective We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. Materials and methods Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16±4 years [mean ± standard deviation; range 9–21 years]). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). Results Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78%±28 [9–100], IVC to LPA: 54%±28 [4–98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R2=0.50, P=0.02; SVC to LPA: R2=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. Conclusion Four-dimensional (4-D) flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability. PMID:27350377
Broadband notch filter design for millimeter-wave plasma diagnostics.
Furtula, V; Michelsen, P K; Leipold, F; Salewski, M; Korsholm, S B; Meo, F; Nielsen, S K; Stejner, M; Moseev, D; Johansen, T
2010-10-01
Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of ∼900 MHz, and a typical insertion loss below 2 dB in the passband of ±9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode in the cylindrical cavities is the fundamental TE(11). The performance of the constructed filter is measured using a vector network analyzer monitoring a total bandwidth of 30 GHz. We compare the measurements with numerical simulations.
Design and performance of a high-Tc superconductor coplanar waveguide filter
NASA Technical Reports Server (NTRS)
Chew, Wilbert; Riley, A. L.; Rascoe, Daniel L.; Hunt, Brian D.; Foote, Marc C.; Cooley, Thomas W.; Bajuk, Louis J.
1991-01-01
The design of a coplanar waveguide low-pass filter made of YBa2Cu3O(7-delta) (YBCO) on an LaAlO3 substrate is described. Measurements were incorporated into simple models for microwave CAD analysis to develop a final design. The patterned and packaged coplanar waveguide low-pass filter of YBCO, with dimensions suited for integrated circuits, exhibited measured insertion losses when cooled in liquid nitrogen superior to those of a similarly cooled thin-film copper filter throughout the 0 to 9.5 GHz passband. Coplanar waveguide models for use with thin-film normal metal (with thickness either greater or less than the skin depth) and YBCO are discussed and used to compare the losses of the measured YBCO and copper circuits.
Flexible Film Bulk Acoustic Wave Filters toward Radiofrequency Wireless Communication.
Jiang, Yuan; Zhao, Yuan; Zhang, Lin; Liu, Bohua; Li, Quanning; Zhang, Menglun; Pang, Wei
2018-03-30
This paper presents a flexible radiofrequency filter with a central frequency of 2.4 GHz based on film bulk acoustic wave resonators (FBARs). The flexible filter consists of five air-gap type FBARs, each comprised of an aluminum nitride piezoelectric thin film sandwiched between two thin-film electrodes. By transfer printing the inorganic film structure from a silicon wafer to an ultrathin polyimide substrate, high electrical performance and mechanical flexibility are achieved. The filter has a peak insertion loss of -1.14 dB, a 3 dB bandwidth of 107 MHz, and a temperature coefficient of frequency of -27 ppm °C -1 . The passband and roll-off characteristics of the flexible filter are comparable with silicon-based commercial products. No electrical performance degradation and mechanical failure occur under bending tests with a bending radius of 2.5 mm or after 100 bending cycles. The flexible FBAR filters are believed to be promising candidates for future flexible wireless communication systems. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cascaded chirped narrow bandpass filter with flat-top based on two-dimensional photonic crystals.
Zhuang, Yuyang; Chen, Heming; Ji, Ke
2017-05-10
We propose a structure of a cascaded chirped narrow bandpass filter with a flat-top based on two-dimensional (2D) photonic crystals (PhCs). The filter discussed here consists of three filter units, each with a resonator and two reflectors. Coupled mode theory and transfer matrix method are methodologies applied in the analysis of the features. The calculations show that the bandwidth of the filter can be adjusted by changing the distances between resonators and reflectors, and based on this, a flat-top response can be achieved by chirped-cascading the filter units. According to the theoretical model, we design a narrow bandpass filter based on 2D PhCs with a triangular lattice of air holes, the parameters of which are calculated using the finite element method. The simulation results show that the filter has a center frequency of 193.40 THz, an insertion loss of 0.18 dB, a flat bandwidth of 40 GHz, and ripples of about 0.2 dB in the passband. The filter is suitable for dense-wavelength-division-multiplexed optical communication systems with 100 GHz channel spacing.
Fung, James Kiujing; Yeung, Victor Hip Wo; Chu, Sau Kwan; Man, Chi Wan
2017-05-01
KILT syndrome is a rare condition composing the triad of kidney and inferior vena cava anomaly and extensive venous thrombosis. We present a case of newly diagnosed KILT syndrome in a 41-years-old gentleman presenting with loin pain and fever. Reviewing previous case reports, KILT syndrome is usually an incidental finding on imaging studies and there is a wide scope of initial clinical presentations. However, recent evidence suggests IVC anomaly may have caused subsequent renal hypoplasia. Identification of the underlying etiology may be helpful in planning early vascular intervention to treat the condition.
Severe cyanosis after Kawashima operation resulting from congenital portosystemic shunt.
Nakamura, Yuki; Aoki, Mitsuru; Hagino, Ikuo; Nakajima, Hiromichi
2012-04-01
We describe an unusual case of a patient with polysplenia, inferior vena cava (IVC) interruption, and unrecognized congenital portosystemic venous connection (CPVC) in whom severe cyanosis developed in the acute postoperative stage after a Kawashima operation and required urgent surgical division of the CPVC. It has been stressed recently that CPVCs and other abdominal venous abnormalities have been underdiagnosed in patients with polysplenia and IVC interruption, and we think that a routine evaluation of abdominal venous connections should be mandatory before considering the Kawashima operation for these patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
2018-05-23
Recurrent Oral Cavity Adenoid Cystic Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Adenoid Cystic Carcinoma; Stage III Major Salivary Gland Cancer AJCC v7; Stage III Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Oral Cavity Adenoid Cystic Carcinoma AJCC v6 and v7; Tongue Carcinoma
NASA Astrophysics Data System (ADS)
Karasawa, Yoshio; Kumagai, Taichi; Takemoto, Atsushi; Fujii, Takeo; Ito, Kenji; Suzuki, Noriyoshi
A novel timing synchronizing scheme is proposed for use in inter-vehicle communication (IVC) with an autonomous distributed intelligent transport system (ITS). The scheme determines the timing of packet signal transmission in the IVC network and employs the guard interval (GI) timing in the orthogonal frequency divisional multiplexing (OFDM) signal currently used for terrestrial broadcasts in the Japanese digital television system (ISDB-T). This signal is used because it is expected that the automotive market will demand the capability for cars to receive terrestrial digital TV broadcasts in the near future. The use of broadcasts by automobiles presupposes that the on-board receivers are capable of accurately detecting the GI timing data in an extremely low carrier-to-noise ratio (CNR) condition regardless of a severe multipath environment which will introduce broad scatter in signal arrival times. Therefore, we analyzed actual broadcast signals received in a moving vehicle in a field experiment and showed that the GI timing signal is detected with the desired accuracy even in the case of extremely low-CNR environments. Some considerations were also given about how to use these findings.
Photodynamic Therapy With HPPH in Treating Patients With Squamous Cell Carcinoma of the Oral Cavity
2016-04-19
Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Oral Cavity
Lunardi, Franciele Osmarini; de Aguiar, Francisco Leo Nascimento; Duarte, Ana Beatriz Graça; Araújo, Valdevane Rocha; de Lima, Laritza Ferreira; Ribeiro de Sá, Naiza Arcângela; Vieira Correia, Hudson Henrique; Domingues, Sheyla Farhayldes Souza; Campello, Cláudio Cabral; Smitz, Johan; de Figueiredo, José Ricardo; Ribeiro Rodrigues, Ana Paula
2016-04-15
Cryopreservation of preantral follicles is a promising technique to preserve female fertility. The aim of this study was to evaluate the effect of vitrification on the development of secondary follicles included in ovarian tissue or isolated after microdissection. An important end point included is the capacity of grown oocytes to resume meiosis. Sheep ovarian cortexes were cut into fragments and split into three different groups: (1) fresh (control): secondary follicles isolated without any previous vitrification; (2) follicle-vitrification (follicle-vit): secondary follicles vitrified in isolated form; and (3) tissue-vitrification (tissue-vit): secondary follicles vitrified within fragments of ovarian tissue (in situ former) and subsequently subjected to isolation. From the three groups, isolated secondary follicles were submitted to IVC for 18 days. After IVC, cumulus-oocyte complexes (COCs) were harvested from follicles. As an additional control group, in vivo grown, in vivo-grown COCs were collected from antral ovarian follicles. All, recovered COCs were matured and the chromatin configuration was evaluated. Data were analyzed by ANOVA, and the means were compared by Student-Newman-Keuls test, and by chi-square. Differences were considered to be significant when P < 0.05. Isolated preantral follicles from all treatments had normal morphology, antrum formation, and low follicle degeneration after IVC. The growth rate between control and follicle-vit did not differ (P > 0.05), and was higher (P < 0.05) than for tissue-vit. The percentage of follicles that decreased diameter during IVC was significantly higher in tissue-vit than the in follicle-vit. Recovery rate of oocytes from normal follicles was higher in follicle-vit than in tissue-vit. Furthermore, oocyte viability was lower in tissue-vit than other treatments, and follicle-vit did not differ from control and in vivo grown. The percentage of oocytes meiosis resuming was not different between treatments except for in vivo grown. After vitrification, only follicle-vit showed metaphase I oocyte. We conclude that secondary follicles vitrified after isolation displayed a better follicular growth rate, oocyte viability, percentage of oocytes reaching the metaphase I stage, and fewer follicles with decreased diameter after IVC. Copyright © 2016 Elsevier Inc. All rights reserved.
Culture of domestic cat ovarian tissue in vitro and in the chick embryo chorioallantoic membrane.
Vilela, J M V; Leonel, E C R; D'Oliveira, L; Paiva, R E G; Miranda-Vilela, A L; Amorim, C A; Pic-Taylor, A; Lucci, C M
2016-10-15
In vitro culture and transplantation procedures are essential protocols employed in the evaluation of ovarian follicle survival and development. Culture in the chorioallantoic membrane (CAM) of chick embryos is an intermediate method that provides important follicle development information and has not been tested for cat ovaries to date. The aim of this study was to investigate if in vitro and CAM culture could be used as short-term systems to study cat ovarian tissue development. The ovaries of eight cats were dissected into 3-mm(3) cubes, cultured in vitro and in CAM for up to 5 days, and stained with hematoxylin-eosin and Gomori trichrome. Cell proliferation was analyzed using anti-Ki67. Possible differences among groups were investigated by analysis of variance or the Kruskal-Wallis test followed by Bonferroni correction. The T-test or Wilcoxon test was used to verify differences between the CAM and IVC. Results revealed that 87.5% of all follicles were primordial during culture. The percentage of primordial follicles in the morphologically normal follicles (MNF) pool was always higher than 80%, with the exception of Day 3 of CAM culture, but the number of MNF reduced significantly from Day 0 (600 out of 777 follicles) to Day 5 in the CAM (91 out of 171) and IVC (296 out of 686). The number of primordial follicles in 1 mm(3) in Days 2, 3, and 5 in the CAM was significantly lower than that in the control (Day 0). No cellular proliferation was observed in culture. Vascularization occurred in the CAM culture, but with no association to follicular viability. In addition, both methods showed an increase in connective tissue during culture. Although no significant differences were observed in the percentage of MNF, there was a reduction in the total number of follicles, both for IVC and CAM-cultured ovarian tissue. Furthermore, anti-Ki67 did not stain any follicle after Day 0 in IVC or in CAM culture. Neither system was capable of promoting follicle growth and/or development. The results show that the CAM is not a suitable system for feline ovarian tissue and highlight the necessity to improve IVC systems in cats. Copyright © 2016 Elsevier Inc. All rights reserved.
Fusion of electromagnetic trackers to improve needle deflection estimation: simulation study.
Sadjadi, Hossein; Hashtrudi-Zaad, Keyvan; Fichtinger, Gabor
2013-10-01
We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.
Marcotegui, J Antonio; Illescas, Jesús Miguel; Estevez, Aritz; Falcone, Francisco
2013-01-01
A new class of broadband microstrip filters for Ultra Wide Band (UWB) applications is proposed. In the design, different stages of parallel-coupled microstrip line and other stages with a Modified Complementary Split Ring Resonator (MCSRR)-a concept proposed here for the first time-are adjusted to obtain the desired response with broadband, sharp rejection, low insertion loss, and low return loss. Full wave simulation results as well as measurement results from fabricated prototypes are presented, showing good agreement. The proposed technique offers a new alternative to implement low-cost high-performance filter devices, applicable to a wide range of communication systems.
Marcotegui, J. Antonio; Illescas, Jesús Miguel; Estevez, Aritz
2013-01-01
A new class of broadband microstrip filters for Ultra Wide Band (UWB) applications is proposed. In the design, different stages of parallel-coupled microstrip line and other stages with a Modified Complementary Split Ring Resonator (MCSRR)—a concept proposed here for the first time—are adjusted to obtain the desired response with broadband, sharp rejection, low insertion loss, and low return loss. Full wave simulation results as well as measurement results from fabricated prototypes are presented, showing good agreement. The proposed technique offers a new alternative to implement low-cost high-performance filter devices, applicable to a wide range of communication systems. PMID:24319366
Crosstalk elimination in the detection of dual-beam optical tweezers by spatial filtering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ott, Dino; Oddershede, Lene B., E-mail: oddershede@nbi.dk; Reihani, S. Nader S.
2014-05-15
In dual-beam optical tweezers, the accuracy of position and force measurements is often compromised by crosstalk between the two detected signals, this crosstalk leading to systematic and significant errors on the measured forces and distances. This is true both for dual-beam optical traps where the splitting of the two traps is done by polarization optics and for dual optical traps constructed by other methods, e.g., holographic tweezers. If the two traps are orthogonally polarized, most often crosstalk is minimized by inserting polarization optics in front of the detector; however, this method is not perfect because of the de-polarization of themore » trapping beam introduced by the required high numerical aperture optics. Here we present a simple and easy-to-implement method to efficiently eliminate crosstalk. The method is based on spatial filtering by simply inserting a pinhole at the correct position and is highly compatible with standard back focal plane photodiode based detection of position and force. Our spatial filtering method reduces crosstalk up to five times better than polarization filtering alone. The effectiveness is dependent on pinhole size and distance between the traps and is here quantified experimentally and reproduced by theoretical modeling. The method here proposed will improve the accuracy of force-distance measurements, e.g., of single molecules, performed by dual-beam optical traps and hence give much more scientific value for the experimental efforts.« less
Hansen, A.D.
1988-01-25
An improved aethalometer having a single light source and a single light detector and two light paths from the light source to the light detector. A quartz fiber filter is inserted in the device, the filter having a collection area in one light path and a reference area in the other light path. A gas flow path through the aethalometer housing allows ambient air to flow through the collection area of the filter so that aerosol particles can be collected on the filter. A rotating disk with an opening therethrough allows light for the light source to pass alternately through the two light paths. The voltage output of the detector is applied to a VCO and the VCO pulses for light transmission separately through the two light paths, are counted and compared to determine the absorption coefficient of the collected aerosol particles. 5 figs.
An Intrinsically Switchable Ladder-Type Ferroelectric BST-on-Si Composite FBAR Filter.
Lee, Seungku; Mortazawi, Amir
2016-03-01
This paper presents a ladder-type bulk acoustic wave (BAW) intrinsically switchable filter based on ferroelectric thin-film bulk acoustic resonators (FBARs). The switchable filter can be turned on and off by the application of an external bias voltage due to the electrostrictive effect in thin-film ferroelectrics. In this paper, Barium Strontium Titanate (BST) is used as the ferroelectric material. A systematic design approach for switchable ladder-type ferroelectric filters is provided based on required filter specifications. A switchable filter is implemented in the form of a BST-on-Si composite structure to control the effective electromechanical coupling coefficient of FBARs. As an experimental verification, a 2.5-stage intrinsically switchable BST-on-Si composite FBAR filter is designed, fabricated, and measured. Measurement results for a typical BST-on-Si composite FBAR show a resonator mechanical quality factor (Q(m)) of 971, as well as a (Q(m)) × f of 2423 GHz. The filter presented here provides a measured insertion loss of 7.8 dB, out-of-band rejection of 26 dB, and fractional bandwidth of 0.33% at 2.5827 GHz when the filter is in the on state at a dc bias of 40 V. In its off state, the filter exhibits an isolation of 31 dB.
40 CFR 35.2030 - Facilities planning.
Code of Federal Regulations, 2010 CFR
2010-07-01
... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2030 Facilities planning. (a... ponds, trickling filters, oxidation ditches, or overland-flow land treatment; and for unsewered portions... a schedule the State accepts and such schedule is inserted as a special condition of the grant...
Use of astronomy filters in fluorescence microscopy.
Piper, Jörg
2012-02-01
Monochrome astronomy filters are well suited for use as excitation or suppression filters in fluorescence microscopy. Because of their particular optical design, such filters can be combined with standard halogen light sources for excitation in many fluorescent probes. In this "low energy excitation," photobleaching (fading) or other irritations of native specimens are avoided. Photomicrographs can be taken from living motile fluorescent specimens also with a flash so that fluorescence images can be created free from indistinctness caused by movement. Special filter cubes or dichroic mirrors are not needed for our method. By use of suitable astronomy filters, fluorescence microscopy can be carried out with standard laboratory microscopes equipped with condensers for bright-field (BF) and dark-field (DF) illumination in transmitted light. In BF excitation, the background brightness can be modulated in tiny steps up to dark or black. Moreover, standard industry microscopes fitted with a vertical illuminator for examinations of opaque probes in DF or BF illumination based on incident light (wafer inspections, for instance) can also be used for excitation in epi-illumination when adequate astronomy filters are inserted as excitatory and suppression filters in the illuminating and imaging light path. In all variants, transmission bands can be modulated by transmission shift.
The effects of vincristine on platelet aggregation studied by a filter loop technique in the rat.
Bee, D.; Leach, E.; Martin, J. F.; Suggett, A. J.
1980-01-01
1 A method for measuring aggregation of platelets of adenosine diphosphate (ADP) is described using a filter inserted into the flowing aortic blood in the rat. 2 Repeated infusions of ADP resulted in a fall in the calculated aggregation index without significant changes in the platelet count. 3 Vincristine (0.05 mg/kg) intravenously caused significant inhibition of ADP-induced platelet aggregation. 4 Infusion of ADP caused some peripheral vasodilatation though it is unlikely that this contributed to the effects seen to any great extent. PMID:7437636
1988-01-28
EXAFS is the inverse transform of the two peaks in the RSF using a filtering a12 function to isolate the range between I and 4A. Both the frequency...backscattering of different neighbors. This inverse transform contains only one frequency and its envelope of intensity is the backscattering amplitude function...and the inverse transform of the RSF using a fourier filter between 1 and 4A (Solid line). Insert: Radial Structure Function (RSF) analyzed between
Zhang, Wen; Cheng, Ying; Du, Pengcheng; Zhang, Yuanyuan; Jia, Hongbing; Li, Xianping; Wang, Jing; Han, Na; Qiang, Yujun; Chen, Chen; Lu, Jinxing
2017-01-01
Clostridium difficile, the etiological agent of Clostridium difficile infection (CDI), is a gram-positive, spore-forming bacillus that is responsible for ∼20% of antibiotic-related cases of diarrhea and nearly all cases of pseudomembranous colitis. Previous data have shown that a substantial proportion (11%) of the C. difficile genome consists of mobile genetic elements, including seven conjugative transposons. However, the mechanism underlying the formation of a mosaic genome in C. difficile is unknown. The type-IV secretion system (T4SS) is the only secretion system known to transfer DNA segments among bacteria. We searched genome databases to identify a candidate T4SS in C. difficile that could transfer DNA among different C. difficile strains. All T4SS gene clusters in C. difficile are located within genomic islands (GIs), which have variable lengths and structures and are all conjugative transposons. During the horizontal-transfer process of T4SS GIs within the C. difficile population, the excision sites were altered, resulting in different short-tandem repeat sequences among the T4SS GIs, as well as different chromosomal insertion sites and additional regions in the GIs.
Adult Wilms tumor: Case report.
Morabito, V; Guglielmo, N; Melandro, F; Mazzesi, G; Alesini, F; Bosco, S; Berloco, P B
2015-01-01
Wilms tumor (WT) occurs infrequently in adults. Even rarer is adult WT with extension by direct intravascular spread into the right side of the heart. The present report describes a WT with intracaval and intracardiac extension in a 38-year-young man. In addition, thrombus extension above the infrahepatic IVC represents a major technical topic for surgeons because of the possible occurrence of uncontrollable hemorrhages and tumor fragmentation. We report the results of a surgical approach to caval thrombosis including the isolation of the IVC from the liver as routinely performed during liver harvesting. The morphologic and immune-histochemical findings confirmed the diagnosis. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sano, Futoshi; Fusayasu, Syusei; Otake, Shinji; Yamanaka, Hiroyuki; Tatenuma, Tomoyuki; Sakata, Ryoko; Makiyama, Kazuhide; Nakaigawa, Noboru; Yao, Masahiro; Kubota, Yoshinobu
2013-10-01
A 72-year-old man presenting with a 14-cm left renal mass, an inferior vena cava (IVC) tumor thrombus, and pulmonary metastases underwent renal mass biopsy that revealed clear cell renal cell carcinoma. Because of metastases and the extent of the tumor thrombus, sunitinib was administered, which resulted in a marked reduction in the tumor thrombus (from level III to level II after 11 weeks of treatment). Ultrasonography, preceding computed tomography, showed a slight shrinkage of the tumor thrombus level in the first 2 weeks. Therefore, ultrasound may be advantageous to monitor the IVC tumor thrombus level during the early phase of targeted therapy.
NASA Technical Reports Server (NTRS)
Subramanyam, Guru; VanKeuls, Fred; Miranda, Felix A.
1998-01-01
We report on YBa2Cu3O(7-delta) (YBCO) thin film/SrTiO3 (STO) thin film K-band tunable bandpass filters on LaAlO3 (LAO) dielectric substrates. The 2 pole filter has a center frequency of 19 GHz and a 4% bandwidth. Tunability is achieved through the non-linear dc electric field dependence of the relative dielectric constant of STO(epsilon(sub rSTO). A large tunability ((Delta)f/f(sub 0) = (f(sub Vmax) - f(sub 0)/f(sub 0), where f(sub 0) is the center frequency of the filter at no bias and f(sub Vmax) is the center frequency of the filter at the maximum applied bias) of greater than 10% was obtained in YBCO/STO/LAO microstrip bandpass filters operating below 77 K. A center frequency shift of 2.3 GHz (i.e., a tunability factor of approximately 15%) was obtained at a 400 V bipolar dc bias, and 30 K, with minimal degradation in the insertion loss of the filter. This paper addresses design, fabrication and testing of tunable filters based on STO ferroelectric thin films. The performance of the YBCO/STO/LAO filters is compared to that of gold/STO/LAO counterparts.
NASA Astrophysics Data System (ADS)
Kwak, J. S.; Lee, J. H.; Kim, C. O.; Hong, J. P.; Han, S. K.; Char, K.
2002-07-01
Highly selective high-temperature superconducting band-pass filters based on spiral meander line structures have been developed for base transceiver station applications of digital cellular communication systems. The filter comprised 12-pole microstrip line resonators with a circuit size of 0.5 × 17 × 41 mm3. The filter was designed to have a bandwidth of 25 MHz at a centre frequency of 834 MHz. Particularly, the physical size of each resonator was chosen not only to reduce far-field radiation, but also to have reasonable tunability in the filter. Device characteristics exhibited a low insertion loss of 0.4 dB with a 0.2 dB ripple and a return loss better than 10 dB in the pass-band at 65 K. The out-of-band signals were attenuated better than 60 dB at about 3.5 MHz from the lower band edge, and 3.8 MHz from the higher band edge.
Design and Analysis of a Micromachined LC Low Pass Filter For 2.4GHz Application
NASA Astrophysics Data System (ADS)
Saroj, Samruddhi R.; Rathee, Vishal R.; Pande, Rajesh S.
2018-02-01
This paper reports design and analysis of a passive low pass filter with cut-off frequency of 2.4 GHz using MEMS (Micro Electro-Mechanical Systems) technology. The passive components such as suspended spiral inductors and metal-insulator-metal (MIM) capacitor are arranged in T network form to implement LC low pass filter design. This design employs a simple approach of suspension thereby reducing parasitic losses to eliminate the performance degrading effects caused by integrating an off-chip inductor in the filter circuit proposed to be developed on a low cost silicon substrate using RF-MEMS components. The filter occupies only 2.1 mm x 0.66 mm die area and is designed using micro-strip transmission line placed on a silicon substrate. The design is implemented in High Frequency Structural Simulator (HFSS) software and fabrication flow is proposed for its implementation. The simulated results show that the design has an insertion loss of -4.98 dB and return loss of -2.60dB.
Waveguide-coupled resonator filters on AlN on silicon
NASA Technical Reports Server (NTRS)
Liaw, H. M.; Cameron, T. P.; Hunt, W. D.; Hickernell, F. S.
1994-01-01
In the effort to continually reduce the size and cost of wireless communications products the level of integration has improved dramatically in recent years. In order to reduce future generations of wireless systems to single chip form, there is a need for on-chip filtering capabilities. In this paper, the first report of an experimental waveguide-coupled resonator filter for cellular radio applications is presented. Measured results indicate a typical insertion loss of 26 dB at a center frequency of 132 MHz using a 2 um AlN film on (001) less than 110 greater than Si. In addition, a laser probe analysis has been conducted and a theoretical analysis of the first order reflection coefficients is presented.
Tunable dual-channel filter based on the photonic crystal with air defects.
Zhao, Xiaodan; Yang, Yibiao; Wen, Jianhua; Chen, Zhihui; Zhang, Mingda; Fei, Hongming; Hao, Yuying
2017-07-01
We propose a tuning filter containing two channels by inserting a defect layer (Air/Si/Air/Si/Air) into a one-dimensional photonic crystal of Si/SiO 2 , which is on the symmetry of the defect. Two transmission peaks (1528.98 and 1564.74 nm) appear in the optical communication S-band and C-band, and the transmittance of these two channels is up to 100%. In addition, this design realizes multi-channel filtering to process large dynamic range or multiple independent signals in the near-infrared band by changing the structure. The tuning range will be enlarged, and the channels can be moved in this range through the easy control of air thickness and incident angle.
Pollastro, R.M.
1982-01-01
Extremely well-oriented clay mineral mounts for X-ray diffraction analysis can be prepared quickly and without introducing segregation using the filter-membrane peel technique. Mounting problems encountered with smectite-rich samples can be resolved by using minimal sample and partial air-drying of the clay film before transfer to a glass slide. Samples containing small quantities of clay can produce useful oriented specimens if Teflon masks having more restrictive areas are inserted above the membrane filter during clay deposition. War]page and thermal shock of glass slides can be controlled by using a flat, porous, ceramic plate as a holding surface during heat treatments.
Switchable multi-wavelength fiber laser based on modal interference
NASA Astrophysics Data System (ADS)
Ma, Lin; Jiang, Sun; Qi, Yan-Hui; Kang, Ze-Xin; Jian, Shui-Sheng
2015-08-01
A comb fiber filter based on modal interference is proposed and demonstrated in this paper. Here two cascaded up-tapers are used to excite the cladding mode, and a core-offset jointing point is used to act as an interference component. Experimental results show that this kind of structure possesses a comb filter property in a range of the C-band. The measured extinction ratio is better than 12 dB with an insertion loss of about 11 dB. A switchable multi-wavelength erbium-doped fiber laser based on this novel comb filter is demonstrated. By adjusting the polarization controller, the output laser can be switched among single-, dual-, and three-wavelengths with a side mode suppression ratio of better than 45 dB.
NASA Astrophysics Data System (ADS)
Ejrnaes, M.; Parlato, L.; Arpaia, R.; Bauch, T.; Lombardi, F.; Cristiano, R.; Tafuri, F.; Pepe, G. P.
2017-12-01
We have fabricated several 10 nm thick and 65 nm wide YBa2Cu3O7-δ (YBCO) nanostrips. The nanostrips with the highest critical current densities are characterized by hysteretic current voltage characteristics (IVCs) with a direct bistable switch from the zero-voltage to the finite voltage state. The presence of hysteretic IVCs allowed the observation of dark pulses due to fluctuations phenomena. The key role of the bistable behavior is its ability to transform a small disturbance (e.g. an intrinsic fluctuation) into a measurable transient signal, i.e. a dark pulse. On the contrary, in devices characterized by lower critical current density values, the IVCs are non-hysteretic and dark pulses have not been observed. To investigate the physical origin of the dark pulses, we have measured the bias current dependence of the dark pulse rate: the observed exponential increase with the bias current is compatible with mechanisms based on thermal activation of magnetic vortices in the nanostrip. We believe that the successful amplification of small fluctuation events into measurable signals in nanostrips of ultrathin YBCO is a milestone for further investigation of YBCO nanostrips for superconducting nanostrip single photon detectors and other quantum detectors for operation at higher temperatures.
One-stage surgery for removal of intravascular leiomyomatosis extending to right ventricle.
Chiang, Ching-Shu; Chen, Po-Lin; Kuo, Tzu-Ting; Chen, I-Ming; Wu, Nai-Yuan; Chang, Hsiao-Huang
2018-03-01
Intravascular leiomyomatosis (IVL) is a rare nonmalignant tumor that can be fatal if untreated. A 49-year-old nulliparous Asian woman who underwent hysterectomy and left salpingo-oophorectomy for multiple uterine leiomyomas 18 months prior presented complaining of intermittent palpitation and chest tightness for approximately 1 month. Echocardiography revealed a large mobile tumor mass extending from the inferior vena cava (IVC) to the right atrium that partially obstructed IVC flow and tricuspid inflow. Thoracicabdominopelvic computed tomography revealed a left adnexal tumor (4.8 × 2.5 cm) causing intravascular obstruction extending from the left internal iliac vein to the IVC, right atrium, and right ventricle. IVL with right heart involvement INTERVENTIONS:: Under cardiopulmonary bypass, a one-stage surgery combining sternotomy and laparotomy was performed. The tumor was approached and extracted via sternotomy, and tumor detachment and removal of residual tumors was accomplished via laparotomy. A firm, smooth, and regularly shape tumor 15.5 × 5.5 × 2.5 in size was completely removed and histopathologically confirmed as IVL. The patient tolerated the surgical procedure well and no postoperative complication was noted. We describe a one-stage surgical approach to completely remove an IVL extending to the right ventricle.
Anaya-Ayala, Javier E; Adams, Matthew K; Telich-Tarriba, Jose E; Dresser, Kelly L; Ismail, Nyla; Peden, Eric K
2013-01-01
Chronic occlusions of the inferior vena cava (IVC) and iliofemoral veins are long-term sequelae of deep venous thrombosis (DVT) that can lead to postthrombotic syndrome (PTS). Patients may present with a wide spectrum of signs and symptoms, ranging from mild discomfort and swelling to severe venous hypertension and ulcerations. We report a 68-year-old man who had a history of left lower extremity DVT after a laminectomy and who developed PTS with nonhealing ulcers. The patient underwent a cross-pubic femorofemoral venous bypass that failed to improve his clinical status. After unsuccessful endovascular attempts for recanalization of the iliofemoral segment, a profunda femoris to IVC bypass was performed. The symptoms recurred 2 years later. Venography revealed restenosis at the caval anastomosis that did not resolve by endovascular means. A surgical revision was performed, and given the quality of the IVC, a jump bypass was created to the left renal vein. The swelling improved and the ulcers healed completely. Twenty-eight months after the complex reconstructions, he remains ulcer-free with mild edema controlled with stockings. Venous reconstructions remain a viable option for patients with symptomatic and recalcitrant nonmalignant obstruction of the large veins. Copyright © 2013 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Shi, Wan-Yin; Wu, Shuang; Hu, Lan-Yue; Liu, Chang-Jian; Gu, Jian-Ping
2015-01-01
To evaluate the feasibility of a swine model of thrombotic inferior vena cava (IVC) occlusion (IVCO) created by autologous thrombus injection with assistance of intra-caval net knitting. Sixteen pigs were included and divided into two groups: Group A (n = 10), IVCO model created by knitting a caval net followed by autologous thrombus injection; Group B (n = 6), control model created by knitting a net and normal saline injection. Venography was performed to assess each model and the associated thrombotic occlusion. The vessels were examined histologically to analyse the pathological changes postoperatively. IVCO model was successfully created in 10 animals in Group A (100%). Immediate venography showed extensive clot burden in the IVC. Postoperative venography revealed partial caval occlusion at 7 days, and complete occlusion coupled with collateral vessels at 14 days. Histologically, Group A animals had significantly greater venous wall thickening, with CD163-positive and CD3-positive cell infiltration. Recanalization channels were observed at the margins of the thrombus. By contrast, no thrombotic occlusion of the IVC was observed in Group B. The thrombotic IVCO model can be reliably established in swine. The inflammatory reaction may contribute to the caval thrombus propagation following occlusion. PMID:26680253
NASA Astrophysics Data System (ADS)
Wang, J.; Xin, L. P.; Qiu, Y. L.; Xu, D. W.; Wei, J. Y.
2018-03-01
By using the line ratio C IV λ1549/C II λ1335 as a tracer of the ionization ratio of the interstellar medium (ISM) illuminated by a long gamma-ray burst (LGRB), we identify a global photoionization response of the ionization ratio to the photon luminosity of the prompt emission assessed by either L iso/E peak or {L}iso}/{E}peak}2. The ionization ratio increases with both L iso/E peak and L iso/E 2 peak for a majority of the LGRBs in our sample, although there are a few outliers. The identified dependence of C IV/C II on {L}iso}/{E}peak}2 suggests that the scatter of the widely accepted Amati relation is related to the ionization ratio in the ISM. The outliers tend to have relatively high C IV/C II values as well as relatively high C IV λ1549/Si IV λ1403 ratios, which suggests an existence of Wolf–Rayet stars in the environment of these LGRBs. We finally argue that the outliers and the LGRBs following the identified C IV/C II‑L iso/E peak ({L}iso}/{E}peak}2) correlation might come from different progenitors with different local environments.
Overview of MPEG internet video coding
NASA Astrophysics Data System (ADS)
Wang, R. G.; Li, G.; Park, S.; Kim, J.; Huang, T.; Jang, E. S.; Gao, W.
2015-09-01
MPEG has produced standards that have provided the industry with the best video compression technologies. In order to address the diversified needs of the Internet, MPEG issued the Call for Proposals (CfP) for internet video coding in July, 2011. It is anticipated that any patent declaration associated with the Baseline Profile of this standard will indicate that the patent owner is prepared to grant a free of charge license to an unrestricted number of applicants on a worldwide, non-discriminatory basis and under other reasonable terms and conditions to make, use, and sell implementations of the Baseline Profile of this standard in accordance with the ITU-T/ITU-R/ISO/IEC Common Patent Policy. Three different codecs had responded to the CfP, which are WVC, VCB and IVC. WVC was proposed jointly by Apple, Cisco, Fraunhofer HHI, Magnum Semiconductor, Polycom and RIM etc. it's in fact AVC baseline. VCB was proposed by Google, and it's in fact VP8. IVC was proposed by several Universities (Peking University, Tsinghua University, Zhejiang University, Hanyang University and Korea Aerospace University etc.) and its coding tools was developed from Zero. In this paper, we give an overview of the coding tools in IVC, and evaluate its performance by comparing it with WVC, VCB and AVC High Profile.
Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L
2014-09-01
A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Design of HTS filter for GSM-R communication system
NASA Astrophysics Data System (ADS)
Cui, Hongyu; Ji, Laiyun
2018-04-01
High-temperature superconducting materials with its excellent performance have increasingly been valued by industries, especially in the field of electronic information. The superconducting material has almost zero surface resistance, and the filter made of it has the characteristics of low insertion loss, high edge steepness and good out-of-band rejection. It has higher selectivity for the desired signal and thus less interference from adjacent channels Signal interference, and noise reduction coefficient can improve the ability to detect weak signals. This design is suitable for high temperature superconducting filter of GSM-R communication system, which can overcome many shortcomings of the traditional GSM-R. The filter is made of DyBCO, a high temperature superconducting thin film material based on magnesium oxide (MgO) substrate with the dielectric constant of 9.7, the center frequency at 887.5MHz, bandwidth of 5MHz.
RF-MEMS tunable interdigitated capacitor and fixed spiral inductor for band pass filter applications
NASA Astrophysics Data System (ADS)
Bade, Ladon Ahmed; Dennis, John Ojur; Khir, M. Haris Md; Wen, Wong Peng
2016-11-01
This research presents the tunable Radio Frequency Micro Electromechanical Systems (RF-MEMS) coupled band-pass filter (BPF), which possess a wide tuning range and constructed by using the Chebyshev fourth degree equivalent circuit consisting of fixed inductors and interdigitated tunable capacitors. The suggested method was authenticated by designing a new tunable BPF with a 100% tuning range from 3.1 GHz to 4.9 GHz. The Metal Multi-User MEMS Process (Metal MUMPs) was involved in the process of design of this band-pass filter. It aimed to achieve the reconfiguration of frequencies and show high efficiency of RF in the applications that using Ultra Wide Band (UWB) such as wireless sensor networks. The RF performance of this filter was found to be very satisfactory due to its simple fabrication. Moreover, it showed less insertion loss of around 4 dB and high return loss of around 20 dB.
NASA Astrophysics Data System (ADS)
Kumari, Puja; Mudiganti, Jagadish Chandra
2017-11-01
In this work bandpass filter based on SIW technology with an adequate fractional bandwidth as well as refinement in the stopband performance is presented. Its application lies with the receiver filter working in the Ka band used mainly in the ground terminal for satellite communication. Additionally analysis of divergent input/output arrangement is also demonstrated. Three SIW filter having a varying passband from 19.2GHz -21.2GHz depending on the input/output are synthesized on a planar substrate having height of 0.508mm RT/duroid 6002 using periodically arranged metal via holes through a regulated PCB process. Simulated outputs has a in-band insertion loss 0.9dB and the improved stopband attenuation within the frequency range of 29.5GHz - 31GHz is around 45 dB. It is observed that the experimented results coincide completely with the results simulated in HFSS/CST.
Seyahi, Emire; Caglar, Erkan; Ugurlu, Serdal; Kantarci, Fatih; Hamuryudan, Vedat; Sonsuz, Abdullah; Melikoglu, Melike; Yurdakul, Sebahattin; Yazici, Hasan
2015-04-01
Behçet's syndrome (BS) is a well-recognized cause of Budd-Chiari syndrome (BCS); however, information about its clinical characteristics and outcome is limited. We reviewed the records of about 9000 patients with BS registered at the multidisciplinary Behçet's syndrome outpatient clinic at Cerrahpasa Medical Faculty between July 1977 and October 2013. We identified 43 (40 M/3 F) patients who were diagnosed as having BCS. Their outcome was evaluated between September 2012 and October 2013. In total, 33 patients (77%) had presented with liver-related symptoms (Group I), while 10 (23%) were asymptomatic for liver disease (Group II). This latter group had presented with symptoms related to the presence of major vessel disease such as fever, leg swelling, or dyspnea. The site of venous obstruction determined in 41 patients was inferior vena cava (IVC) and hepatic veins combined in 25 (61%), IVC alone in 12 (29%), and only hepatic veins in 4 patients (10%). The number of patients with concurrent obstruction in the hepatic veins and the IVC was less in Group II than in Group I (3/10 vs 22/31, p = 0.06). A total of 20 (19 M/1 F) patients (47%) had died at a median of 10 months after diagnosis. Mortality was significantly lower in Group II (10%) than in Group I (58%), (p = 0.011). By the end of the survey, 23 patients were alive, of whom 21 could be re-evaluated at the clinic. BCS associated with BS is usually due to IVC thrombosis with or without hepatic vein thrombosis. Silent cases exist and have a better prognosis. The mortality rate among the patients symptomatic for liver disease remains high. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ganguli, Suvranu, E-mail: sganguli@partners.org; Kalva, Sanjeeva; Oklu, Rahmi
Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found tomore » have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12-72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 {+-} 20.2 months (range 3.8-54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.« less
Ciesiółka, S; Bryja, A; Budna, J; Kranc, W; Chachuła, A; Bukowska, D; Piotrowska, H; Porowski, L; Antosik, P; Bruska, M; Brüssow, K P; Nowicki, M; Zabel, M; Kempisty, B
2016-01-01
The process of oocyte growth and development takes place during long stages of folliculogenesis and oogenesis. This is accompanied by biochemical and morphological changes, occurring from the preantral to antral stages during ovarian follicle differentiation. It is well known that the process of follicle growth is associated with morphological modifications of theca (TCs) and granulosa cells (GCs). However, the relationship between proliferation and/or differentiation of porcine GCs during long-term in vitro culture requires further investigation. Moreover, the expression of cytokeratins and vimentin in porcine GCs, in relation to real-time cell proliferation, has yet to be explored. Utilizing confocal microscopy, we analyzed cytokeratin 18 (CK18), cytokeratin 8 + 18 + 19 (panCK), and vimentin (Vim) expression, as well as their protein distribution, within GCs isolated from slaughtered ovarian follicles. The cells were cultured for 168 h with protein expression and cell proliferation index analyzed at 24-h intervals. We found the highest expression of CK18, panCK, and Vim occurred at 120 h of in vitro culture (IVC) as compared with other experimental time intervals. All of the investigated proteins displayed cytoplasmic distribution. Analysis of real-time cell proliferation revealed an increased cell index after the first 24 h of IVC. Additionally, during each period between 24-168 h of IVC, a significant difference in the proliferation profile, expressed as the cell index, was also observed. We concluded that higher expression of vimentin at 120 h of in vitro proliferation might explain the culmination of the stromalization process associated with growth and domination of stromal cells in GC culture. Cytokeratin expression within GC cytoplasm confirms the presence of epithelial cells as well as epithelial-related GC development during IVC. Moreover, expression of both cytokeratins and vimentin during short-term culture suggests that the process of GC proliferation is also highly associated with porcine ovarian follicular granulosa cell differentiation in vitro.
Design of an S band narrow-band bandpass BAW filter
NASA Astrophysics Data System (ADS)
Gao, Yang; Zhao, Kun-li; Han, Chao
2017-11-01
An S band narrowband bandpass filter BAW with center frequency 2.460 GHz, bandwidth 41MHz, band insertion loss - 1.154 dB, the passband ripple 0.9 dB, the out of band rejection about -42.5dB@2.385 GHz; -45.5dB@2.506 GHz was designed for potential UAV measurement and control applications. According to the design specifications, the design is as follows: each FBAR's stack was designed in BAW filter by using Mason model. Each FBAR's shape was designed with the method of apodization electrode. The layout of BAW filter was designed. The acoustic-electromagnetic cosimulation model was built to validate the performance of the designed BAW filter. The presented design procedure is a common one, and there are two characteristics: 1) an A and EM co-simulation method is used for the final BAW filter performance validation in the design stage, thus ensures over-optimistic designs by the bare 1D Mason model are found and rejected in time; 2) An in-house developed auto-layout method is used to get compact BAW filter layout, which simplifies iterative error-and-try work here and output necessary in-plane geometry information to the A and EM cosimulation model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kassa, Mateos; Hall, Carrie; Ickes, Andrew
Advanced internal combustion engines, although generally more efficient than conventional combustion engines, often encounter limitations in multi-cylinder applications due to variations in the combustion process encountered across cylinders and between cycles. This study leverages experimental data from an inline 6-cylinder heavy-duty dual fuel engine equipped with exhaust gas recirculation (EGR), a variable geometry turbocharger, and a fully-flexible variable intake valve actuation system to study cylinder-to-cylinder variations in power production and the underlying uneven fuel distribution that causes these variations. The engine is operated with late intake valve closure timings in a dual-fuel combustion mode in which a high reactivity fuelmore » is directly injected into the cylinders and a low reactivity fuel is port injected into the cylinders. Both dual fuel implementation and late intake valve closing (IVC) timings have been shown to improve thermal efficiency. However, experimental data from this study reveal that when late IVC timings are used on a multi-cylinder dual fuel engine a significant variation in IMEP across cylinders results and as such, leads to efficiency losses. The difference in IMEP between the different cylinders ranges from 9% at an IVC of 570°ATDC to 38% at an IVC of 610°ATDC and indicates an increasingly uneven fuel distribution. These experimental observations along with engine simulation models developed using GT-Power have been used to better understand the distribution of the port injected fuel across cylinders under various operating conditions on such dual fuel engines. This study revealed that the fuel distribution across cylinders in this dual fuel application is significantly affected by changes in the effective compression ratio as determined by the intake valve close timing as well as the design of the intake system (specifically the length of the intake runners). Late intake valve closures allow a portion of the trapped air and port injected fuel to flow back out of the cylinders into the intake manifold. The fuel that is pushed back in the intake manifold is then unevenly redistributed across the cylinders largely due to the dominating direction of the flow in the intake manifold. The effects of IVC as well as the impact of intake runner length on fuel distribution were quantitatively analyzed and a model was developed that can be used to accurately predict the fuel distribution of the port injected fuel at different operating conditions with an average estimation error of 1.5% in cylinder-specific fuel flow.« less
2012-07-06
Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Colon Cancer; Recurrent Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Recurrent Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage IV Adenoid Cystic Carcinoma of the Oral Cavity; Stage IV Basal Cell Carcinoma of the Lip; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Lymphoepithelioma of the Oropharynx; Stage IV Mucoepidermoid Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IV Squamous Cell Carcinoma of the Oropharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IV Verrucous Carcinoma of the Oral Cavity; Stage IVA Colon Cancer; Stage IVA Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Colon Cancer; Stage IVB Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Tongue Cancer
Fernandez, Silvina; Murzicato, Sofía; Sandoval, Orlando; Fernández-Canigia, Liliana; Mollerach, Marta
2015-01-01
Community-acquired methicillin-resistant Staphylococcus aureus is the first cause of skin and soft tissue infections, but can also produce severe diseases such as bacteremia, osteomyelitis and necrotizing pneumonia. Some S. aureus lineages have been described in cases of necrotizing pneumonia worldwide, usually in young, previously healthy patients. In this work, we describe a fatal case of necrotizing pneumonia due to community-acquired methicillin-resistant S. aureus clone ST30-SCCmecIVc-spat019-PVL positive in an immunocompetent adult patient. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Chao, Michael C.; Pritchard, Justin R.; Zhang, Yanjia J.; Rubin, Eric J.; Livny, Jonathan; Davis, Brigid M.; Waldor, Matthew K.
2013-01-01
The coupling of high-density transposon mutagenesis to high-throughput DNA sequencing (transposon-insertion sequencing) enables simultaneous and genome-wide assessment of the contributions of individual loci to bacterial growth and survival. We have refined analysis of transposon-insertion sequencing data by normalizing for the effect of DNA replication on sequencing output and using a hidden Markov model (HMM)-based filter to exploit heretofore unappreciated information inherent in all transposon-insertion sequencing data sets. The HMM can smooth variations in read abundance and thereby reduce the effects of read noise, as well as permit fine scale mapping that is independent of genomic annotation and enable classification of loci into several functional categories (e.g. essential, domain essential or ‘sick’). We generated a high-resolution map of genomic loci (encompassing both intra- and intergenic sequences) that are required or beneficial for in vitro growth of the cholera pathogen, Vibrio cholerae. This work uncovered new metabolic and physiologic requirements for V. cholerae survival, and by combining transposon-insertion sequencing and transcriptomic data sets, we also identified several novel noncoding RNA species that contribute to V. cholerae growth. Our findings suggest that HMM-based approaches will enhance extraction of biological meaning from transposon-insertion sequencing genomic data. PMID:23901011
DOE Office of Scientific and Technical Information (OSTI.GOV)
Villa, Enrique, E-mail: villae@unican.es; Aja, Beatriz; Cagigas, Jaime
2013-12-15
This paper presents the analysis, design, and characterization of a wideband 90° phase switch in Ka-band. The phase switch is based on two microstrip bandpass filters in which the commutation is performed by a novel single-pole double-throw (SPDT) switch. The analysis of π-network bandpass filters is provided, obtaining the phase difference and amplitude imbalance between filters and their scattering parameters; tested results show an average phase difference of 88.9° ± 5° and an amplitude imbalance of 0.15 dB from 24 to 37 GHz. The new broadband SPDT switch is based on a coplanar waveguide-to-slotline-to-microstrip structure, which enables a full planarmore » integration with shifting branches. PIN diodes are used to perform the switching between outputs. The SPDT shows isolation better than 19 dB, insertion loss of around 1.8 dB, and return loss better than 15 dB. The full integration of the phase switch achieves a return loss better than 11 dB and insertion loss of around 4 dB over the band 26–36 GHz, with an average phase difference of 87.1° ± 4° and an average amplitude imbalance of 0.3 dB. It provides an excellent performance for this frequency range, suitable for radio-astronomy receivers.« less
Micro-optical fiber probe for use in an intravascular Raman endoscope.
Komachi, Yuichi; Sato, Hidetoshi; Aizawa, Katsuo; Tashiro, Hideo
2005-08-01
We believe that we have developed the narrowest optical-fiber Raman probe ever reported, 600 microm in total diameter, that can be inserted into coronary arteries. The selection of suitable optical fibers, filters, and a processing method is discussed. Custom-made filters attached to the front end of a probe eliminate the background Raman signals of the optical fiber itself. The experimental evaluation of various optical fibers is carried out for the selection of suitable fibers. Measurement of the Raman spectra of an atherosclerotic lesion of a rabbit artery in vitro demonstrates the excellent performance of the micro-Raman probe.
Transparent graphene microstrip filters for wireless communications
NASA Astrophysics Data System (ADS)
Wang, Jinchen; Guan, Yifei; Yu, Hua; Li, Na; Wang, Shuopei; Shen, Cheng; Dai, Zhijiang; Gan, Decheng; Yang, Rong; He, Songbai; Zhang, Guangyu
2017-08-01
A microstrip is an indispensable component for wireless communication circuits. With the development of 5G technology, optically transparent microstrip filters urgently need to be developed. In this work, we have theoretically and experimentally demonstrated the immense potential of graphene microstrips for transparent wireless communication circuits in the 5G era. Both wideband and dual-band transparent graphene microstrip filters have shown more than 80% optical transmissivity in the region from 250 nm to 2000 nm with good frequency responses. S and C band microwave signals can transmit along the graphene microstrip lines effectively while coupling excitations produce relatively large insertion losses. Our results show that transparent microstrips designed with high-quality graphene will largely scale down the size of the wireless devices and thus play an irreplaceable role in the 5G era.
21 CFR 874.4800 - Bone particle collector.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...
21 CFR 874.4800 - Bone particle collector.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...
21 CFR 874.4800 - Bone particle collector.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...
21 CFR 874.4800 - Bone particle collector.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...
21 CFR 874.4800 - Bone particle collector.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...
Farajollahi, Farid; Seidenstücker, Axel; Altintoprak, Klara; Walther, Paul; Ziemann, Paul; Plettl, Alfred; Marti, Othmar; Wege, Christina; Gliemann, Hartmut
2018-04-13
Nanoporous membranes are of increasing interest for many applications, such as molecular filters, biosensors, nanofluidic logic and energy conversion devices. To meet high-quality standards, e.g., in molecular separation processes, membranes with well-defined pores in terms of pore diameter and chemical properties are required. However, the preparation of membranes with narrow pore diameter distributions is still challenging. In the work presented here, we demonstrate a strategy, a "pore-in-pore" approach, where the conical pores of a solid state membrane produced by a multi-step top-down lithography procedure are used as a template to insert precisely-formed biomolecular nanodiscs with exactly defined inner and outer diameters. These nanodiscs, which are the building blocks of tobacco mosaic virus-deduced particles, consist of coat proteins, which self-assemble under defined experimental conditions with a stabilizing short RNA. We demonstrate that the insertion of the nanodiscs can be driven either by diffusion due to a concentration gradient or by applying an electric field along the cross-section of the solid state membrane. It is found that the electrophoresis-driven insertion is significantly more effective than the insertion via the concentration gradient.
Farajollahi, Farid; Seidenstücker, Axel; Altintoprak, Klara; Walther, Paul; Ziemann, Paul; Plettl, Alfred; Wege, Christina; Gliemann, Hartmut
2018-01-01
Nanoporous membranes are of increasing interest for many applications, such as molecular filters, biosensors, nanofluidic logic and energy conversion devices. To meet high-quality standards, e.g., in molecular separation processes, membranes with well-defined pores in terms of pore diameter and chemical properties are required. However, the preparation of membranes with narrow pore diameter distributions is still challenging. In the work presented here, we demonstrate a strategy, a “pore-in-pore” approach, where the conical pores of a solid state membrane produced by a multi-step top-down lithography procedure are used as a template to insert precisely-formed biomolecular nanodiscs with exactly defined inner and outer diameters. These nanodiscs, which are the building blocks of tobacco mosaic virus-deduced particles, consist of coat proteins, which self-assemble under defined experimental conditions with a stabilizing short RNA. We demonstrate that the insertion of the nanodiscs can be driven either by diffusion due to a concentration gradient or by applying an electric field along the cross-section of the solid state membrane. It is found that the electrophoresis-driven insertion is significantly more effective than the insertion via the concentration gradient. PMID:29652841
Harper, Martin; Ashley, Kevin
2013-01-01
Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements. PMID:23548078
KAWAKAMI, MANRI; KODA, MASAHIKO; MANDAI, MARI; HOSHO, KEIKO; MURAWAKI, YOSHIKAZU; ODA, WAKAKO; HAYASHI, KAZUHIKO
2013-01-01
The aim of this study was to clarify the clinical features of patients with isolated HCC metastases to the heart. A 66-year-old female hospitalized with a hepatocellular carcinoma (HCC) ranging from the right to the left lobe and with a tumor thrombus in the main portal vein, was treated with intraarterial cisplatin, 5-fluouracil, adriamycin and mitomycin. Computed tomography (CT) one month later revealed that the HCC had progressed with multiple lung metastases and moderate ascites. The patient had no symptoms. Magnetic resonance imaging (MRI) and echocardiography revealed a round, movable tumor with a diameter of 2 cm in the right atrium (RA). The patient succumbed to HCC five months later. An autopsy revealed HCC with portal tumor thrombi and metastases to the lungs, inferior vena cava (IVC) and RA. The metastases in the RA and IVC were not continous with the intrahepatic tumor and were histologically attached to the endocardium and endothelium, respectively. An isolated metastasis of a HCC of the RA and IVC is extremely rare. In conclusion, although the majority of isolated metastases of HCC to the heart were diagnosed by echocardiography and were treated with mainly surgery, they had poor prognosis. The echocardiography should be performed for patients with advanced HCC. A novel treatment including molecular targeted drugs is required. PMID:23760591
NASA Astrophysics Data System (ADS)
Umeshkumar, Dubey Suhmita; Kumar, Manish
2018-04-01
This paper incorporates an improved design of Ultra Wideband Bandpass filter by using split ring resonators (SRR) along with the coupled microstrip lines. The use of split ring resonators and shunt step impedance open circuit stub enhances the stability due to transmission zeroes at the ends. The designing of filter and simulation of parameters is carried out using Ansoft's HFSS 13.0 software on RT/Duroid 6002 as a substrate with dielectric constant of 2.94. The design utilizes a frequency band from 22GHz to 29GHz. This band is reserved for Automotive Radar system and sensors as per FCC specifications. The proposed design demonstrates insertion loss less than 0.6dB and return loss better than 12dB at mid frequency i.e. 24.4GHz. The reflection coefficient shows high stability of about 12.47dB at mid frequency. The fractional bandwidth of the proposed filter is about 28.7% and size of filter design is small due to thickness of 0.127mm.
A Compact Via-free Composite Right/Left Handed Low-pass Filter with Improved Selectivity
NASA Astrophysics Data System (ADS)
Kumar, Ashish; Choudhary, Dilip Kumar; Chaudhary, Raghvendra Kumar
2017-07-01
In this paper, a compact via-free low pass filter is designed based on composite right/left handed (CRLH) concept. The structure uses open ended concept. Rectangular slots are etched on signal transmission line (TL) to suppress the spurious band without altering the performance and size of filter. The filter is designed for low pass frequency band with cut-off frequency of 3.5 GHz. The proposed metamaterial structure has several prominent advantages in term of selectivity up to 34 dB/GHz and compactness with average insertion loss less than 0.4 dB. It has multiple applications in wireless communication (such as GSM900, global navigation satellite system (1.559-1.610 GHz), GSM1800, WLAN/WiFi (2.4-2.49 GHz) and WiMAX (2.5-2.69 GHz)). The design parameters have been measured and compared with the simulated results and found excellent agreement. The electrical size of proposed filter is 0.14λ0× 0.11λ0 (where λ0 is free space wavelength at zeroth order resonance (ZOR) frequency 2.7 GHz).
Compact triple band-stop filter using novel epsilon-shaped metamaterial with lumped capacitor
NASA Astrophysics Data System (ADS)
Ali, W. A. E.; Hamdalla, M. Z. M.
2018-04-01
This paper presents the design of a novel epsilon-shaped metamaterial unit cell structure that is applicable for single-band and multi-band applications. A closed-form formulas to control the resonance frequencies of the proposed design are included. The proposed unit cell, which exhibits negative permeability at its frequency bands, is etched from the ground plane to form a band-stop filter. The filter design is constructed to validate the band-notched characteristics of the proposed unit cell. A lumped capacitor is inserted for size reduction purpose in addition to multi-resonance generation. The fundamental resonance frequency is translated from 3.62 GHz to 2.45 GHz, which means that the filter size will be more compact (more than 32% size reduction). The overall size of the proposed filter is 13 × 6 × 1.524 mm3, where the electrical size is 0.221λg × 0.102λg × 0.026λg at the lower frequency band (2.45 GHz). Two other resonance frequencies are generated at 5.3 GHz and 9.2 GHz, which confirm the multi-band behavior of the proposed filter. Good agreement between simulated and measured characteristics of the fabricated filter prototype is achieved.
22 CFR 121.5 - Apparatus and devices under Category IV(c).
Code of Federal Regulations, 2014 CFR
2014-04-01
... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...
22 CFR 121.5 - Apparatus and devices under Category IV(c).
Code of Federal Regulations, 2012 CFR
2012-04-01
... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...
22 CFR 121.5 - Apparatus and devices under Category IV(c).
Code of Federal Regulations, 2013 CFR
2013-04-01
... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and..., intervalometers, thermal batteries, hardened missile launching facilities, guided missile launchers and...
2018-06-11
Head and Neck Squamous Cell Carcinoma; Human Papillomavirus Negative; Stage III Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v6 and v7; Stage III Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7
Cediranib Maleate With or Without Lenalidomide in Treating Patients With Thyroid Cancer
2018-05-23
Recurrent Thyroid Gland Carcinoma; Stage I Thyroid Gland Follicular Carcinoma AJCC v7; Stage I Thyroid Gland Papillary Carcinoma AJCC v7; Stage II Thyroid Gland Follicular Carcinoma AJCC v7; Stage II Thyroid Gland Papillary Carcinoma AJCC v7; Stage III Thyroid Gland Follicular Carcinoma AJCC v7; Stage III Thyroid Gland Papillary Carcinoma AJCC v7; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7
Methanol Formation via Oxygen Insertion Chemistry in Ices
NASA Astrophysics Data System (ADS)
Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh
2017-08-01
We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.
Gallus, Susanne; Janke, Axel
2017-01-01
Abstract Phylogenetic reconstruction from transposable elements (TEs) offers an additional perspective to study evolutionary processes. However, detecting phylogenetically informative TE insertions requires tedious experimental work, limiting the power of phylogenetic inference. Here, we analyzed the genomes of seven bear species using high-throughput sequencing data to detect thousands of TE insertions. The newly developed pipeline for TE detection called TeddyPi (TE detection and discovery for Phylogenetic Inference) identified 150,513 high-quality TE insertions in the genomes of ursine and tremarctine bears. By integrating different TE insertion callers and using a stringent filtering approach, the TeddyPi pipeline produced highly reliable TE insertion calls, which were confirmed by extensive in vitro validation experiments. Analysis of single nucleotide substitutions in the flanking regions of the TEs shows that these substitutions correlate with the phylogenetic signal from the TE insertions. Our phylogenomic analyses show that TEs are a major driver of genomic variation in bears and enabled phylogenetic reconstruction of a well-resolved species tree, despite strong signals for incomplete lineage sorting and introgression. The analyses show that the Asiatic black, sun, and sloth bear form a monophyletic clade, in which phylogenetic incongruence originates from incomplete lineage sorting. TeddyPi is open source and can be adapted to various TE and structural variation callers. The pipeline makes it possible to confidently extract thousands of TE insertions even from low-coverage genomes (∼10×) of nonmodel organisms. This opens new possibilities for biologists to study phylogenies and evolutionary processes as well as rates and patterns of (retro-)transposition and structural variation. PMID:28985298
Architectural design of a ground-based deep-space optical reception antenna
NASA Technical Reports Server (NTRS)
Kerr, E. L.
1989-01-01
An architectural design of a ground-based antenna (telescope) for receiving optical communications from deep space is presented. Physical and optical parameters, and their effect on the performance and cost considerations, are described. The channel capacity of the antenna is 100 kbits/s from Saturn and 5 Mbits/s from Mars. A novel sunshade is designed to permit optical communication even when the deep-space laser source is as close to the sun as 12 deg. Inserts in the tubes of the sunshade permit operations at solar elongations as small as 6 or 3 deg. The Nd:YAG source laser and the Fraunhofer filter (a narrow-band predetection optical filter) are tuned to match the Doppler shifts of the source and background. A typical Saturn-to-earth data link can reduce its source power requirement from 8.2 W to 2 W of laser output by employing a Fraunhofer filter instead of a conventional multilayer dielectric filter.
All-fiber tunable MMI fiber laser
NASA Astrophysics Data System (ADS)
Antonio-Lopez, J. E.; Castillo-Guzman, A.; May-Arrioja, D. A.; Selvas-Aguilar, R.; LiKamWa, P.
2009-05-01
We report on a novel tuning mechanism to fabricate an all-fiber tunable laser based on multimode interference (MMI) effects. It is well known that the wavelength response of MMI devices exhibits a linear dependence when the length of the multimode fiber (MMF) section. Therefore, tuning in the MMI filter is achieved using a ferrule (capillary tube of 127 μm diameter) filled with a liquid with a higher refractive index than that of the ferrule, which creates a variable liquid MMF. This liquid MMF is used to increase the effective length of the MMI filter and tuning takes place. Using this simple scheme, a tuning range of 30 nm was easily achieved, with very small insertion losses. The filter was tested within a typical Erbium doped fiber (EDF) ring laser cavity, and a tunable EDF laser covering the full C-band was demonstrated. The advantage of our laser is of course the simplicity of the tunable MMI filter, which results in an inexpensive tunable fiber laser.
Channel add-drop filter based on dual photonic crystal cavities in push-pull mode.
Poulton, Christopher V; Zeng, Xiaoge; Wade, Mark T; Popović, Miloš A
2015-09-15
We demonstrate an add-drop filter based on a dual photonic crystal nanobeam cavity system that emulates the operation of a traveling wave resonator, and, thus, provides separation of the through and drop port transmission from the input port. The device is on a 3×3 mm chip fabricated in an advanced microelectronics silicon-on-insulator complementary metal-oxide semiconductor (SOI CMOS) process (IBM 45 nm SOI) without any foundry process modifications. The filter shows 1 dB of insertion loss in the drop port with a 3 dB bandwidth of 64 GHz, and 16 dB extinction in the through port. To the best of our knowledge, this is the first implementation of a port-separating, add-drop filter based on standing wave cavities coupled to conventional waveguides, and demonstrates a performance that suggests potential for photonic crystal devices within optical immersion lithography-based advanced CMOS electronics-photonics integration.
Hansen, Anthony D.
1990-01-01
An improved aethalometer (10) having a single light source (18) and a single light detector (20) and two light paths (21, 22) from the light source (18) to the light detector (20). A quartz fiber filter (13) is inserted in the device, the filter (13) having a collection area (23) in one light path (21) and a reference area (24) in the other light path (22). A gas flow path (46) through the aethalometer housing (11) allows ambient air to flow through the collection area (23) of the filter (13) so that aerosol particles can be collected on the filter. A rotating disk (31) with an opening (33) therethrough allows light for the light source (18) to pass alternately through the two light paths (21, 22). The voltage output of the detector (20) is applied to a VCO (52) and the VCO pulses for light transmission separately through the two light paths (21, 22 ) are counted and compared to determine the absorption coefficient of the collected aerosol particles.
Popliteal Venous Aneurysm: A Rare Cause of Recurrent Pulmonary Emboli and Limb Swelling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, David A., E-mail: davearussell@aol.com; Robinson, Graham J.; Johnson, Brian F.
2008-09-15
Popliteal venous aneurysm is a rare cause of recurrent pulmonary embolism, although the true incidence of aneurysm is probably underestimated. One-third of patients suffer further embolic events despite therapeutic anticoagulation. We report the case of a 59-year-old male who presented with recurrent PEs over a period of 12 years despite anticoagulation therapy. A thrombophilia screen and abdominal ultrasound were normal at that time. He reattended with recurrent pulmonary emboli, left calf swelling, and a mass in his left popliteal fossa causing limitation of knee movement. Venous duplex and MRI of his popliteal fossa demonstrated a thrombosed true popliteal venous aneurysmmore » with popliteal and superficial femoral vein occlusion. In view of the mass effect we proceeded to surgical excision of his aneurysm after prophylactic placement of an IVC filter. The patient regained normal knee function with intensive inpatient physiotherapy. He has been recommenced on lifelong anticoagulant. The presentation, investigation, and management of the condition are briefly discussed. We suggest that a bilateral lower limb duplex is performed to exclude venous aneurysm in all patients presenting with pulmonary embolism in which an underlying source cannot otherwise be identified and no thrombophilic tendency is detected.« less
2010-09-01
interact with neighboring ECMmole- cules to promote this activity. This interaction sometimes pro- motes remodeling of the ECM to create amore conducive...cells remaining on the upper filter were scraped off gently using a cotton swab, and the inserts were gently washed with PBS. Those cells that migrated
Artificial high effective permittivity medium in a SIW filled with metallic cylinders
NASA Astrophysics Data System (ADS)
Vicent, G.; Bronchalo, E.; Coves, A.; Torregrosa, G.
2018-02-01
A new topology of step-impedance band-pass filters in Substrate Integrated Waveguide (SIW) technology has been recently demonstrated in which low effective permittivity regions have been achieved by removing part of the substrate material and then shielding the perforated structure. Alternatively, in this work a new way to obtain an increased relative permittivity in the guiding region is proposed by periodically inserting metallic inclusions. This paper shows the results of a systematic study of the effective permittivity obtained in this way in a SIW in order to synthesize a higher effective permittivity, which can be used in the filter design.
Zamperlini-Netto, G; Zanette, A; Wehbi, E; Williams, S; Grant, R M; Brandao, L R
2016-04-01
Venous thrombotic events (VTE) are becoming more and more common in children, particularly in the hospital setting. To date, 1 in 200 children admitted to tertiary pediatric hospitals are now being recognized to develop VTE. Amongst those patients with an identified thrombotic occlusion, pediatric patients diagnosed with renal tumors have long been recognized, but their ideal management in the instances of vascular invasion remains controversial. We describe the clinical behavior of patients diagnosed with renal tumors and extra renal vascular involvement at The Hospital for Sick Children in Toronto, Canada. A retrospective analysis was conducted in patients diagnosed from 1990 to 2012. Data collected included: age, gender, symptoms at presentation, staging, pathology report, radiological evidence of intravascular thrombus [i.e. renal veins (RV), inferior vena cava (IVC) and right atrium (RA)], intraoperative findings, therapeutic protocol implemented and anticoagulation; for outcomes, tumor and/or thrombus recurrence, thromboembolic phenomena [i.e. pulmonary embolism (PE)] and survival. Of 299 patients with renal tumors identified, 292 were included: Wilms (219), Renal Cell Carcinoma (RCC, 29), Clear Cell Sarcoma of the Kidney (CCSK, 12), others (32). The median age of the group was 4.53years (4days - 18 years). Extra renal vascular disease was identified in 29 patients, with a median age 7.05years (0.6-16 years; p=0.03), including Wilms tumors (22/219, 10%), RCC (2/29, 7%), CCSK (1/12, 8.3%) and others (4/32, 12.5%; p=0.01). Vascular involvement comprised exclusive evidence of RV disease (7), IVC disease (19; 15 infra-hepatic), RA disease (3) and PE (5).Treatment escalation because of vascular disease included neo-adjuvant chemotherapy (12; Wilms [11], RCC [1]), intraoperative cavectomy/ thrombectomy (1; Wilms), and cavotomies (11 Wilms [7], RCC [1], CCSK [1], PNET [1], sarcoma [1]). Four patients were placed under cardiopulmonary bypass. Anticoagulation was administered in 9/29 patients for their tumor-related thrombus, and one had a minor bleeding complications (oozing from the central venous line insertion site). Renal tumors with vascular invasion are a rare and challenging entity. Treatment included mostly cancer-related therapies and the role of vascular surgical approaches and/or systemic anticoagulation remains to be clarified. © 2016 Elsevier Ltd. All rights reserved.
Machuca, Mayra Alejandra; Sosa, Luis Miguel; González, Clara Isabel
2013-01-01
Background Staphylococcus aureus is among the most common global nosocomial pathogens. The emergence and spread of methicillin-resistant Staphylococcus aureus (MRSA) is a public health problem worldwide that causes nosocomial and community infections. The goals of this study were to establish the clonal complexes (CC) of the isolates of MRSA obtained from pediatric patients in a university hospital in Colombia and to investigate its molecular characteristics based on the virulence genes and the genes of staphylococcal toxins and adhesins. Methods A total of 53 MRSA isolates from pediatric patients with local or systemic infections were collected. The MRSA isolates were typed based on the SCCmec, MLST, spa and agr genes. The molecular characterization included the detection of Panton-Valentine Leukocidin, superantigenic and exfoliative toxins, and adhesin genes. The correlation between the molecular types identified and the profile of virulence factors was determined for all isolates. Results Four CC were identified, including CC8, CC5, CC80 and CC78. The ST8-MRSA-IVc-agrI was the predominant clone among the isolates, followed by the ST5-MRSA-I-agrII and ST5-MRSA-IVc-agrII clones. Twelve spa types were identified, of which t10796 and t10799 were new repeat sequences. The isolates were carriers of toxin genes, and hlg (100%), sek (92%) and pvl (88%) were the most frequent. Ten toxin gene profiles were observed, and the most frequent were seq-sek-hlg (22.6%), sek-hlg (22.6%), seb-seq-sek-hlg (18.9%) and seb-sek-hlg (15.1%). The adhesion genes were present in most of the MRSA isolates, including the following: clf-A (89%), clf-B (87%), fnb-A (83%) and ica (83%). The majority of the strains carried SCCmec-IVc and were identified as causing nosocomial infection. No significant association between a molecular type and the virulence factors was found. Conclusion Four major MRSA clone complexes were identified among the isolates. ST8-MRSA-IVc-agrI pvl+ (USA300-LV) was the most frequent, confirming the presence of community-associated MRSA in Colombian hospitals. PMID:24058415
76 FR 14923 - Endangered and Threatened Species; Take of Anadromous Fish
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-18
... (i.e., surface and bottom water temperature, salinity, near bottom dissolved oxygen concentration...-water and bottom trawls) are adequately characterizing schools of hake. The IVC research would take...
Sener, Aysin; Erkin, Yuksel; Sener, Alper; Tasdogen, Aydin; Dokumaci, Esra; Elar, Zahide
2015-01-01
Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. The bacterial adhesion capability of the two filters was measured in vitro experiment. Adhesion capacities for standard Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) strains of the two different filters (Portex and Rusch) which have the same pore size were examined. Bacterial suspension of 0.5 Mc Farland was placed in the patient-controlled analgesia pump, was filtered at a speed of 5mL/h. in continuous infusion for 48h and accumulated in bottle. The two filters were compared with colony counts of bacteria in the filters and bottles. At the same time, the filters and adhered bacteria were monitored by scanning electron microscope. Electron microscopic examination of filters showed that the Portex filter had a granular and the Rusch filter fibrillary structure. Colony counting from the catheter and bottle showed that both of the filters have significant bacterial adhesion capability (p<0.001). After the bacteria suspension infusion, colony countings showed that the Portex filter was more efficient (p<0.001). There was not any difference between S. aureus and P. aeruginosa bacteria adhesion. In the SEM monitoring after the infusion, it was physically shown that the bacteria were adhered efficiently by both of the filters. The granular structured filter was found statistically and significantly more successful than the fibrial. Although the pore sizes of the filters were same - of which structural differences shown by SEM were the same - it would not be right to attribute the changes in the efficiencies to only structural differences. Using microbiological and physical proofs with regard to efficiency at the same time has been another important aspect of this experiment. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Sener, Aysin; Erkin, Yuksel; Sener, Alper; Tasdogen, Aydin; Dokumaci, Esra; Elar, Zahide
2015-01-01
Epidural catheter bacteria filters are barriers in the patient-controlled analgesia/anaesthesia for preventing contamination at the epidural insertion site. The efficiency of these filters varies according to pore sizes and materials. The bacterial adhesion capability of the two filters was measured in vitro experiment. Adhesion capacities for standard Staphylococcus aureus (ATCC 25923) and Pseudomonas aeruginosa (ATCC 27853) strains of the two different filters (Portex and Rusch) which have the same pore size were examined. Bacterial suspension of 0.5 Mc Farland was placed in the patient-controlled analgesia pump, was filtered at a speed of 5 mL/h. in continuous infusion for 48 h and accumulated in bottle. The two filters were compared with colony counts of bacteria in the filters and bottles. At the same time, the filters and adhered bacteria were monitored by scanning electron microscope. Electron microscopic examination of filters showed that the Portex filter had a granular and the Rusch filter fibrillary structure. Colony counting from the catheter and bottle showed that both of the filters have significant bacterial adhesion capability (p<0.001). After the bacteria suspension infusion, colony countings showed that the Portex filter was more efficient (p<0.001). There was not any difference between S. aureus and P. aeruginosa bacteria adhesion. In the SEM monitoring after the infusion, it was physically shown that the bacteria were adhered efficiently by both of the filters. The granular structured filter was found statistically and significantly more successful than the fibrial. Although the pore sizes of the filters were same - of which structural differences shown by SEM were the same - it would not be right to attribute the changes in the efficiencies to only structural differences. Using microbiological and physical proofs with regard to efficiency at the same time has been another important aspect of this experiment. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
22 CFR 121.5 - Apparatus and devices under Category IV(c).
Code of Federal Regulations, 2010 CFR
2010-04-01
..., modified or configured for items listed in that category, bomb racks and shackles, bomb shackle release units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...
The need for venovenous bypass in liver transplantation
Fonouni*, Hamidreza; Soleimani, Mehrdad; Müller, Sascha A.; Büchler, Markus W.; Schmidt, Jan
2008-01-01
Since introduction of the conventional liver transplantation (CLTx) by Starzl, which was based on the resection of recipient inferior vena cava (IVC) along the liver, the procedure has undergone several refinements. Successful use of venovenous bypass (VVB) was first introduced by Shaw et al., although in recent decades there has been controversy regarding the routine use of VVB during CLTx. With development of piggyback liver transplantation (PLTx), the use of caval clamping and VVB is avoided, leading to fewer complications related to VVB. However, some authors still advocate VVB in PLTx. The great diversity among centers in their use of VVB during CLTx, or even along the PLTx technique, has led to confusion regarding the indication setting for VVB. For this reason, we present an overview of the use of VVB in CLTx, the target of patients for whom VVB could be beneficial, and the needs assessment of VVB for patients undergoing PLTx. Recent studies have shown that with the advancement of surgical skills, refinement of surgical techniques, and improvements in anesthesiology, there are only limited indications for doing CLTx with VVB routinely. PLTx with preservation of IVC can be performed in almost all primary transplants and in the majority of re-transplantations without the need for VVB. Nevertheless, in a few selective cases with severe intra-operative hemodynamic instability, or with a failed test of transient IVC occlusion, the application of VVB is still justifiable. These indications should be judged intra-operatively and the decision is based on each center's preference. PMID:18773054
Naito, Michiko; Yu, Hee Chul; Kim, Ji Hyun; Rodríguez-Vázquez, José Francisco; Murakami, Gen; Cho, Baik Hwan
2015-07-01
To understand anomalies in Chiari's network better, we assessed the topographical anatomy of the fetal inferior vena cava (IVC), coronary sinus, and atria. We examined sagittal serial paraffin sections of 15 human fetuses of crown-rump length 24-36 mm, corresponding to a gestational age of 8 weeks. Although their outflow tract morphologies were similar, these 15 specimens could be classified into two groups. In eight specimens, the left common cardinal vein reached the body wall, whereas in the other seven the vein was obliterated near the left pulmonary vein. Irrespective of the group in which the specimen was included, the anteroposterior arrangement of the coronary sinus, the sinus septum (septum), and the right sinus valve (right valve) could be classified into three types: the right valve-septum-coronary sinus arrangement in seven specimens; the right valve-coronary sinus-septum arrangement in five; and the coronary sinus-right valve-septum arrangement in three. Depending on differences in topographical anatomy, the sinus septum separated the coronary sinus opening from either the right or the left atrium. Likewise, the coronary sinus opening was either adjacent to or distant from the IVC terminal. Rather than the counter-side position of the right valve being at the IVC terminal, the left sinus valve protruded leftward, forming an incomplete interatrial septum. Fetal variations seemed to be closely connected with individual variations and a high frequency of Chiari's network anomalies in adults. © 2014 Wiley Periodicals, Inc.
48-hours administration of fenoterol in spontaneous preterm labor - does it affect fetal preload?
Grzesiak, Mariusz; Forys, Sebastian; Sobczak, Malgorzata; Ahmed, Rehana B; Wilczynski, Jan
2013-01-01
to investigate whether any changes in the preload index (PLI) occur within the first 48 hours of fenoterol intravenous tocolysis. Doppler evaluation of placental and fetal circulation was performed in 36 pregnant women prior to fenoterol administration and after 24/48 hours. Measurements were obtained from a longitudinal section of the inferior vena cava (IVC) and preload index was calculated. To determine changes over time, an all study variable analysis of variance (ANOVA) for repeated measurements, followed by Tukey-Kramer's multiple comparison test was used. The effects of additional clinical covariates were checked. The maternal heart rate values were significantly increased after 24 hours and 48 hours in comparison to pre-treatment values. No significant changes in fetal heart rate were observed during treatment. The fetal IVC PLI values were significantly reduced after 24 hours and 48 hours of treatment. The increase in PLI values when comparing 24 and 48 hours results were not statistically significant. These observations were consistent with ANOVA post-hoc analysis. 48 hours intravenous administration of fenoterol appears not to alter inferior vena cava blood flow by itself. The reduction in PLI values may reflect lower fetal preload conditions during the course of successful tocolytic treatment. Therefore, Doppler IVC PLI measurement should be considered as a possible additional assessment method of effectiveness of treatment. However, other Doppler venous blood flow parameters should be assessed to confirm the results and clarify whether maternal corticosteroids administration may be interfering with the results.
Vanacker, Julie; Luyckx, Valérie; Dolmans, Marie-Madeleine; Des Rieux, Anne; Jaeger, Jonathan; Van Langendonckt, Anne; Donnez, Jacques; Amorim, Christiani A
2012-09-01
For women diagnosed with leukemia, transplantation of cryopreserved ovarian tissue after disease remission is not advisable. Therefore, to restore fertility in these patients, we aim to develop a biodegradable artificial ovary that offers an environment where isolated follicles and ovarian cells (OCs) can survive and grow. Four NMRI mice were ovariectomized and their ovaries used to isolate OCs. Groups of 50,000 OCs were embedded in an alginate-matrigel matrix for further fixation (fresh controls), one week of in vitro culture (IVC) or heterotopic autografting. OC proliferation (Ki67), apoptosis (TUNEL), scaffold degradation, vessel formation (CD34) and inflammation (CD45) were analyzed. Ki67-positive OCs were found in 2.3%, 9.0% and 15.5% cells of cases in fresh, IVC and grafted beads respectively, while cells were TUNEL-positive in 0%, 1.5% and 6.9% of cases. After IVC or grafting, the beads degraded, losing their original round aspect, and infiltrating blood capillaries could be observed in the grafted beads. CD34-positive cells and 22% CD45-positive cells were found around and inside the matrix. In conclusion, our results demonstrate that an alginate-based matrix is a promising proposition to graft isolated OCs. After transplantation, this matrix was able to degrade, allowed vascularization and elicited a low inflammatory response. Copyright © 2012 Elsevier Ltd. All rights reserved.
Torres, V; Hamdi, M; Millán de la Blanca, M G; Urrego, R; Echeverri, J; López-Herrera, A; Rizos, D; Gutiérrez-Adán, A; Sánchez-Calabuig, M J
2018-03-26
Antioxidants have been widely used during in vitro production to decrease the negative effect of reactive oxygen species. It was reported that the complex resveratrol-methyl β-cyclodextrin (RV-CD) improves resveratrol's stability and bioavailability and increases its antioxidant activity. This study evaluates the effect of RV-CD during in vitro oocyte maturation (IVM) or in vitro embryo culture (IVC) on developmental competence and quantitative changes in gene expression of developmental important genes. In experiment 1, RV-CD was added to IVM media and maturation level, embryo development and oocytes, cumulus cells, and blastocysts gene expression by RT-qPCR were examined. In experiment 2, presumptive zygotes were cultured in SOF supplemented with RV-CD and embryo development and blastocysts gene expression by RT-qPCR were studied. A group without RV-CD (control - ) and a group with cyclodextrin (control + ) were included. No differences were found in cleavage rate or blastocyst yield between groups. However, the expression of LIPE was higher in blastocysts derived from oocytes treated with resveratrol compared with control groups (p < .05). Blastocysts produced by IVC with resveratrol showed that RV-CD could modify the expression of genes related to lipid metabolism (CYP51A1, PNPLA2 and MTORC1) compared with control groups (p < .05). RV-CD in the IVM and IVC media could reduce accumulated fat by increasing lipolysis and suppressing lipogenesis of blastocysts. © 2018 Blackwell Verlag GmbH.
2013-01-08
Recurrent Non-small Cell Lung Cancer; Recurrent Ovarian Epithelial Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage IIIA Non-small Cell Lung Cancer; Stage IIIA Ovarian Epithelial Cancer; Stage IIIB Non-small Cell Lung Cancer; Stage IIIB Ovarian Epithelial Cancer; Stage IIIC Ovarian Epithelial Cancer; Stage IV Non-small Cell Lung Cancer; Stage IV Ovarian Epithelial Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx
Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni
2017-06-19
The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.
A Rapid Filter Insert-based 3D Culture System for Primary Prostate Cell Differentiation
Tricoli, Lucas; Berry, Deborah L.; Albanese, Chris
2018-01-01
Conditionally reprogrammed cells (CRCs) provide a sustainable method for primary cell culture and the ability to develop extensive “living biobanks” of patient derived cell lines. For many types of epithelial cells, various three dimensional (3D) culture approaches have been described that support an improved differentiated state. While CRCs retain their lineage commitment to the tissue from which they are isolated, they fail to express many of the differentiation markers associated with the tissue of origin when grown under normal two dimensional (2D) culture conditions. To enhance the application of patient-derived CRCs for prostate cancer research, a 3D culture format has been defined that enables a rapid (2 weeks total) luminal cell differentiation in both normal and tumor-derived prostate epithelial cells. Herein, a filter insert-based format is described for the culturing and differentiation of both normal and malignant prostate CRCs. A detailed description of the procedures required for cell collection and processing for immunohistochemical and immunofluorescent staining are provided. Collectively the 3D culture format described, combined with the primary CRC lines, provides an important medium- to high- throughput model system for biospecimen-based prostate research. PMID:28287583
Lammers, Fritjof; Gallus, Susanne; Janke, Axel; Nilsson, Maria A
2017-10-01
Phylogenetic reconstruction from transposable elements (TEs) offers an additional perspective to study evolutionary processes. However, detecting phylogenetically informative TE insertions requires tedious experimental work, limiting the power of phylogenetic inference. Here, we analyzed the genomes of seven bear species using high-throughput sequencing data to detect thousands of TE insertions. The newly developed pipeline for TE detection called TeddyPi (TE detection and discovery for Phylogenetic Inference) identified 150,513 high-quality TE insertions in the genomes of ursine and tremarctine bears. By integrating different TE insertion callers and using a stringent filtering approach, the TeddyPi pipeline produced highly reliable TE insertion calls, which were confirmed by extensive in vitro validation experiments. Analysis of single nucleotide substitutions in the flanking regions of the TEs shows that these substitutions correlate with the phylogenetic signal from the TE insertions. Our phylogenomic analyses show that TEs are a major driver of genomic variation in bears and enabled phylogenetic reconstruction of a well-resolved species tree, despite strong signals for incomplete lineage sorting and introgression. The analyses show that the Asiatic black, sun, and sloth bear form a monophyletic clade, in which phylogenetic incongruence originates from incomplete lineage sorting. TeddyPi is open source and can be adapted to various TE and structural variation callers. The pipeline makes it possible to confidently extract thousands of TE insertions even from low-coverage genomes (∼10×) of nonmodel organisms. This opens new possibilities for biologists to study phylogenies and evolutionary processes as well as rates and patterns of (retro-)transposition and structural variation. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.
Methanol Formation via Oxygen Insertion Chemistry in Ices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh
We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observemore » no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.« less