Sample records for jaama peep kasearu

  1. Effect of external PEEP in patients under controlled mechanical ventilation with an auto-PEEP of 5 cmH2O or higher.

    PubMed

    Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Berruto, Francesco; Fiorillo, Marialinda; Peratoner, Alberto; Tinnirello, Andrea; Filippini, Matteo; Marsilia, Paolo F; Minelli, Cosetta; Bernardini, Achille

    2016-12-01

    In some patients with auto-positive end-expiratory pressure (auto-PEEP), application of PEEP lower than auto-PEEP maintains a constant total PEEP, therefore reducing the inspiratory threshold load without detrimental cardiovascular or respiratory effects. We refer to these patients as "complete PEEP-absorbers." Conversely, adverse effects of PEEP application could occur in patients with auto-PEEP when the total PEEP rises as a consequence. From a pathophysiological perspective, all subjects with flow limitation are expected to be "complete PEEP-absorbers," whereas PEEP should increase total PEEP in all other patients. This study aimed to empirically assess the extent to which flow limitation alone explains a "complete PEEP-absorber" behavior (i.e., absence of further hyperinflation with PEEP), and to identify other factors associated with it. One hundred patients with auto-PEEP of at least 5 cmH2O at zero end-expiratory pressure (ZEEP) during controlled mechanical ventilation were enrolled. Total PEEP (i.e., end-expiratory plateau pressure) was measured both at ZEEP and after applied PEEP equal to 80 % of auto-PEEP measured at ZEEP. All measurements were repeated three times, and the average value was used for analysis. Forty-seven percent of the patients suffered from chronic pulmonary disease and 52 % from acute pulmonary disease; 61 % showed flow limitation at ZEEP, assessed by manual compression of the abdomen. The mean total PEEP was 7 ± 2 cmH2O at ZEEP and 9 ± 2 cmH2O after the application of PEEP (p < 0.001). Thirty-three percent of the patients were "complete PEEP-absorbers." Multiple logistic regression was used to predict the behavior of "complete PEEP-absorber." The best model included a respiratory rate lower than 20 breaths/min and the presence of flow limitation. The predictive ability of the model was excellent, with an overoptimism-corrected area under the receiver operating characteristics curve of 0.89 (95 % CI 0

  2. Assessment of Factors Related to Auto-PEEP.

    PubMed

    Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille

    2016-02-01

    Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by

  3. End-systolic pressure-volume relationships in dogs during ventilation with PEEP.

    PubMed

    Crottogini, A J; Willshaw, P; Barra, J G; Breitbart, G J; Pichel, R H

    1988-04-01

    Whether left ventricular (LV) contractility changes during ventilation with positive end-expiratory pressure (PEEP) remains controversial. To assess LV inotropic state during PEEP using a load-independent index, we generated end-systolic pressure-volume relationships (ESPVRs) in eight closed-chest, chronically instrumented, anesthetized dogs undergoing 0 [zero end-expiratory pressure for the 1st time (ZEEP1)], 5 (PEEP-5), 10 (PEEP-10), and again 0 (ZEEP2) cmH2O PEEP. LV volume was calculated from three orthogonal internal diameters (sonomicrometry), and LV pressure was measured using an implanted transducer. ESPVRs at each level of PEEP were generated by transient inflation of a vena caval occluder. Despite significant decreases in cardiac output with PEEP-5 (1.81 +/- 0.38 l/min, means +/- SE; P less than 0.05) and PEEP-10 (1.70 +/- 0.46; P less than 0.01) with respect to ZEEP1 (2.12 +/- 0.41), no change was found in the slope (ZEEP1: 6.99 +/- 1.03 mmHg/ml; PEEP-5: 7.48 +/- 1.20; PEEP-10: 7.17 +/- 1.02; ZEEP2: 7.38 +/- 1.02), the volume intercept (ZEEP1: 7.4 +/- 3.4 ml; PEEP-5: 6.6 +/- 3.0; PEEP-10: 7.2 +/- 4.0; ZEEP2: 6.6 +/- 3.6), or the new index area beneath the ESPVR (ZEEP1: 304 +/- 98; PEEP-5: 329 +/- 104; PEEP-10: 310 +/- 98; ZEEP2: 343 +/- 114). We conclude that these levels of PEEP do not affect LV contractility as assessed by the ESPVR.

  4. Double-lumen tubes and auto-PEEP during one-lung ventilation.

    PubMed

    Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T

    2016-01-01

    Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Hyperdynamic sepsis modifies a PEEP-mediated redistribution in organ blood flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bersten, A.D.; Gnidec, A.A.; Rutledge, F.S.

    Changes in organ blood flow (Q) produced by 20 cm H2O positive end-expiratory pressure (PEEP) were measured before and after the induction of hyperdynamic sepsis in nine unanesthetized sheep. During the baseline nonseptic study, PEEP was associated with a 9% fall in thermodilution-measured systemic Q, although arterial perfusing pressures were unaffected. Concurrently, microsphere-derived Q was maintained to the brain and heart, but fell to liver, spleen, pancreas, kidney, large intestine, and gastrocnemius. Twenty-four to 36 h after cecal ligation and perforation, a pre-PEEP septic study demonstrated an increase in all of the cardiac index (CI) and systemic O2 delivery whenmore » compared with the nonseptic study, whereas whole-body O2 extraction was depressed. Although PEEP depressed systemic Q during the septic study to a greater extent than during the nonseptic study (p less than 0.02), absolute organ Q fell only to pancreas, liver, and spleen. Relative to the simultaneous fall in the CI, Q to some splanchnic organs was not depressed by PEEP to the same magnitude in the septic as in the nonseptic study. When an infusion of Ringer's lactate subsequently restored systemic Q to pre-PEEP septic levels, individual flows that had been depressed by PEEP were not restored. Furthermore, Q-kidney continued to fall, such that the postfluid Q-kidney (-19%) was significantly less than was demonstrated in the pre-PEEP septic study. We postulate that differences noted in the distribution of organ Q between the nonseptic and hyperdynamic septic studies after the application of PEEP were secondary to the vasculopathy of sepsis and/or an alteration in the function of specific organ microcirculations. However, these data do not address whether the changes in organ Q distribution after a PEEP-mediated depression in systemic Q during sepsis significantly restricted tissue DO2.« less

  6. Optimizing PEEP by Electrical Impedance Tomography in a Porcine Animal Model of ARDS.

    PubMed

    Hochhausen, Nadine; Biener, Ingeborg; Rossaint, Rolf; Follmann, Andreas; Bleilevens, Christian; Braunschweig, Till; Leonhardt, Steffen; Czaplik, Michael

    2017-03-01

    Mechanical ventilation is necessary in diverse clinical circumstances. Especially in the context of ARDS, so-called protective ventilation strategies must be followed. It is already known that PEEP might enhance oxygenation in ARDS. However, determining the optimal PEEP settings in clinical routines is challenging. Electrical impedance tomography (EIT) is a promising technique with which to adjust ventilator settings. We investigated whether the combination of different EIT parameters, namely the global inhomogeneity and hyperdistension indices, may lead to a feasible and safe PEEP setting. ARDS was induced by a double-hit approach in 18 pigs weighing, on average, 34.8 ± 3.97 kg. First, a surfactant washout was conducted; second, the tidal volume was increased to 20 mL/kg body weight, triggering a ventilator-induced lung injury. Subsequently, pigs were randomized to either the EIT or control groups, followed by an observation time of 24 h. In the control group, PEEP was set according to the ARDS network table. In the EIT group, a PEEP trial was conducted to determine an appropriate PEEP. At defined time points, hemodynamic measures, ventilation parameters, and EIT recordings, as well as blood samples, were taken. After euthanization, lungs were removed for subsequent histopathological and cytological examination. The combination of PEEP and F IO 2 differed between groups, although respiratory compliance, gas exchange, and histopathological examinations, as well as hemodynamics, did not show any statistical differences between the EIT and control groups. However, in the control group, the PEEP/F IO 2 settings followed the given coupling; in the EIT group, divergent individual combinations of PEEP and F IO 2 ranges occurred. PEEP setting by EIT facilitates a more individual ventilation therapy. However, in our relatively short ARDS observation period of 24 h, no significant differences appeared in common clinical parameters compared with a control group. Copyright

  7. Should PEEP Titration Be Based on Chest Mechanics in Patients With ARDS?

    PubMed

    Kallet, Richard H

    2016-06-01

    Functional residual capacity (FRC) is essentially the alveolar volume and a determinant of both oxygenation and respiratory system compliance (CRS). ARDS decreases FRC, and sufficient PEEP restores FRC; thus, assessments of PEEP by its impact on oxygenation and CRS are intimately linked. PEEP also can ameliorate or aggravate ventilator-induced lung injury. Therefore, it can be argued that PEEP should be titrated primarily by its impact on CRS The pro position argues that the heterogeneous nature of lung injury and its unique presentation in individual patients results in an uncoupling between oxygenation and CRS Therefore, relying upon oxygenation alone may enhance lung injury and mortality risk, particularly in those with severe ARDS. The con argument is that the preponderance of preclinical and clinical evidence suggests that a relatively narrow range of PEEP is required to manage all but the most severe cases of ARDS. In addition, pathological alterations in chest wall compliance confuse the interpretation of chest mechanics. Moreover, ambiguities and technical limitations in advanced techniques, such as esophageal manometry and pressure-volume curves, add a layer of complexity that renders its broader application in all ARDS patients both impractical and unnecessary. Whether sophisticated monitoring of chest mechanics in severe ARDS might improve outcomes further is open to question and should be studied further. However, it is highly improbable that we will ever discover a PEEP strategy that optimizes all aspects of cardiorespiratory function and chest mechanics for individual patients suffering from ARDS. Copyright © 2016 by Daedalus Enterprises.

  8. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    PubMed

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P < 0.001], with parallel changes in QPA Neither PEEP nor volume state altered RVR (P = 0.489). MSFPinsp_hold overestimated MSFPRAO [16.5 (SD 5.8) vs. 13.6 (SD 3.2) mmHg, P = 0.001; mean difference 3.0 (SD 5.1) mmHg]. Inspiratory holds shifted the RAP/QPA relationship rightward in euvolemia because inferior vena cava flow (QIVC) recovered early after an inspiratory hold nadir. The QIVC nadir was lowest after bleeding [36% (SD 24%) of preinspiratory hold at 15 cmH2O inspiratory pressure], and the QIVC recovery was most complete at the lowest inspiratory pressures independent of volume state [range from 80% (SD 7%) after bleeding to 103% (SD 8%) at PEEP 10 cmH2O of QIVC before inspiratory hold]. The QIVC recovery thus defends venous return, possibly via hepatosplanchnic vascular waterfall. Copyright © 2016 the American Physiological Society.

  9. Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study.

    PubMed

    Zhou, Jing; Han, Yi

    2016-01-01

    To analyze the ability of pleth variability index (PVI) and respiratory system compliance (RSC) on evaluating the hemodynamic and respiratory effects of positive end expiratory pressure (PEEP), then to direct PEEP settings in mechanically ventilated critical patients. We studied 22 mechanically ventilated critical patients in the intensive care unit. Patients were monitored with classical monitor and a pulse co-oximeter, with pulse sensors attached to patients' index fingers. Hemodynamic data [heart rate (HR), perfusion index (PI), PVI, central venous pressure (CVP), mean arterial pressure (MAP), peripheral blood oxygen saturation (SPO2), peripheral blood oxygen content (SPOC) and peripheral blood hemoglobin (SPHB)] as well as the respiratory data [respiratory rate (RR), tidal volume (VT), RSC and controlled airway pressure] were recorded for 15 min each at 3 different levels of PEEP (0, 5 and 10 cmH2O). Different levels of PEEP (0, 5 and 10 cmH2O) had no obvious effect on RR, HR, MAP, SPO2 and SPOC. However, 10 cmH2O PEEP induced significant hemodynamic disturbances, including decreases of PI, and increases of both PVI and CVP. Meanwhile, 5 cmH2O PEEP induced no significant changes on hemodynamics such as CVP, PI and PVI, but improved the RSC. RSC and PVI may be useful in detecting the hemodynamic and respiratory effects of PEEP, thus may help clinicians individualize PEEP settings in mechanically ventilated patients.

  10. Effects of vascular flow and PEEP in a multiple hit model of lung injury in isolated perfused rabbit lungs.

    PubMed

    Piacentini, Enrique; López-Aguilar, Josefina; García-Martín, Carolina; Villagrá, Ana; Saenz-Valiente, Alicia; Murias, Gastón; Fernández-Segoviano, Pilar; Hotchkiss, John R; Blanch, Lluis

    2008-07-01

    High vascular flow aggravates lung damage in animal models of ventilator-induced lung injury. Positive end-expiratory pressure (PEEP) can attenuate ventilator-induced lung injury, but its continued effectiveness in the setting of antecedent lung injury is unclear. The objective of the present study was to evaluate whether the application of PEEP diminishes lung injury induced by concurrent high vascular flow and high alveolar pressures in normal lungs and in a preinjury lung model. Two series of experiments were performed. Fifteen sets of isolated rabbit lungs were randomized into three groups (n = 5): low vascular flow/low PEEP; high vascular flow/low PEEP, and high vascular flow/high PEEP. Subsequently, the same protocol was applied in an additional 15 sets of isolated rabbit lungs in which oleic acid was added to the vascular perfusate to produce mild to moderate lung injury. All lungs were ventilated with peak airway pressure of 30 cm H2O for 30 minutes. Outcome measures included frequency of gross structural failure, pulmonary hemorrhage, edema formation, changes in static compliance, pulmonary vascular resistance, and pulmonary ultrafiltration coefficient. In the context of high vascular flow, application of a moderate level of PEEP reduced pulmonary rupture, edema formation, and lung hemorrhage. The protective effects of PEEP were not observed in lungs concurrently injured with oleic acid. Under these experimental conditions, PEEP attenuates lung injury in the setting of high vascular flow. The protective effect of PEEP is lost in a two-hit model of lung injury.

  11. The development of a vocabulary for PEEPS-SE-profiles of early expressive phonological skills for Swedish.

    PubMed

    Marklund, Ulrika; Lacerda, Francisco; Persson, Anna; Lohmander, Anette

    2018-04-10

    This paper describes the development of a vocabulary for Profiles of Early Expressive Phonological Skills for Swedish (PEEPS-SE), a tool for assessment of expressive phonology in Swedish-learning children in the age range of 18-36 months. PEEPS-SE is the Swedish version of the original PEEPS, Profiles of Early Expressive Phonological Skills, which uses two age-adequate word lists-a basic word list (BWL) for the assessment of 18-24-month-old children, to which an expanded word list (EWL) is added for assessment of 24-36-month-old children, or children with more than 250 words in their expressive vocabulary. The selection of words in PEEPS-SE is based on two types of criteria: age of acquisition and phonological complexity. The words also need to be easy to elicit in a natural way in test situations. Vocabulary data previously collected with the Swedish Early Communicative Development Inventory are used for selection of age-adequate words, where the BWL contains words acquired earlier compared to the additional words in the EWL. The latter also contains words that are more phonologically complex compared to those in the BWL. Word complexity was determined by the Swedish version of word complexity measure. PEEPS-SE has made an attempt to match the original version of PEEPS in terms of both assessment method and word selection.

  12. PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery

    PubMed Central

    2011-01-01

    Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP), followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP), associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG) were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p < 0.001) compared with other pressures during the assessment periods; however, they were within lung safe limits. The expiratory flow before the procedure were 33 ± 7.87 L/min, increasing significantly during the procedure to 60 ± 6.54 L/min (p < 0.001), diminishing to 35 ± 8.17 L/min at 10 minutes and to 36 ± 8.48 L/min at 30 minutes. Hemodynamic and oxygenation variables were not altered. Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG. PMID:21914178

  13. PEEP Annual Report, April 1999-March 2000.

    ERIC Educational Resources Information Center

    Peers Early Education Partnership, Oxford (England).

    The goal of England's Peers Early Education Partnership (PEEP) is to support early communication and literacy skills and to support parents as their children's first educators through both home- and group-based programs. The program is currently offered to all children under 5 years of age and their families in a disadvantaged area of Oxford. This…

  14. Evaluation of lung and chest wall mechanics during anaesthesia using the PEEP-step method.

    PubMed

    Persson, P; Stenqvist, O; Lundin, S

    2018-04-01

    Postoperative pulmonary complications are common. Between patients there are differences in lung and chest wall mechanics. Individualised mechanical ventilation based on measurement of transpulmonary pressures would be a step forward. A previously described method evaluates lung and chest wall mechanics from a change of ΔPEEP and calculation of change in end-expiratory lung volume (ΔEELV). The aim of the present study was to validate this PEEP-step method (PSM) during general anaesthesia by comparing it with the conventional method using oesophageal pressure (PES) measurements. In 24 lung healthy subjects (BMI 18.5-32), three different sizes of PEEP steps were performed during general anaesthesia and ΔEELVs were calculated. Transpulmonary driving pressure (ΔPL) for a tidal volume equal to each ΔEELV was measured using PES measurements and compared to ΔPEEP with limits of agreement and intraclass correlation coefficients (ICC). ΔPL calculated with both methods was compared with a Bland-Altman plot. Mean differences between ΔPEEP and ΔPL were <0.15 cm H 2 O, 95% limits of agreements -2.1 to 2.0 cm H 2 O, ICC 0.6-0.83. Mean differences between ΔPL calculated by both methods were <0.2 cm H 2 O. Ratio of lung elastance and respiratory system elastance was 0.5-0.95. The large variation in mechanical properties among the lung healthy patients stresses the need for individualised ventilator settings based on measurements of lung and chest wall mechanics. The agreement between ΔPLs measured by the two methods during general anaesthesia suggests the use of the non-invasive PSM in this patient population. NCT 02830516. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. The Crazy Business of Internet Peeping, Privacy, and Anonymity.

    ERIC Educational Resources Information Center

    Van Horn, Royal

    2000-01-01

    Peeping software takes several forms and can be used on a network or to monitor a certain computer. E-Mail Plus, for example, hides inside a computer and sends exact copies of incoming or outgoing e-mail anywhere. School staff with monitored computers should demand e-mail privacy. (MLH)

  16. Effect of PEEP and Tidal Volume on Ventilation Distribution and End-Expiratory Lung Volume: A Prospective Experimental Animal and Pilot Clinical Study

    PubMed Central

    Becher, Tobias; Schädler, Dirk; Pulletz, Sven; Freitag-Wolf, Sandra; Weiler, Norbert; Frerichs, Inéz

    2013-01-01

    Introduction Lung-protective ventilation aims at using low tidal volumes (VT) at optimum positive end-expiratory pressures (PEEP). Optimum PEEP should recruit atelectatic lung regions and avoid tidal recruitment and end-inspiratory overinflation. We examined the effect of VT and PEEP on ventilation distribution, regional respiratory system compliance (CRS), and end-expiratory lung volume (EELV) in an animal model of acute lung injury (ALI) and patients with ARDS by using electrical impedance tomography (EIT) with the aim to assess tidal recruitment and overinflation. Methods EIT examinations were performed in 10 anaesthetized pigs with normal lungs ventilated at 5 and 10 ml/kg body weight VT and 5 cmH2O PEEP. After ALI induction, 10 ml/kg VT and 10 cmH2O PEEP were applied. Afterwards, PEEP was set according to the pressure-volume curve. Animals were randomized to either low or high VT ventilation changed after 30 minutes in a crossover design. Ventilation distribution, regional CRS and changes in EELV were analyzed. The same measures were determined in five ARDS patients examined during low and high VT ventilation (6 and 10 (8) ml/kg) at three PEEP levels. Results In healthy animals, high compared to low VT increased CRS and ventilation in dependent lung regions implying tidal recruitment. ALI reduced CRS and EELV in all regions without changing ventilation distribution. Pressure-volume curve-derived PEEP of 21±4 cmH2O (mean±SD) resulted in comparable increase in CRS in dependent and decrease in non-dependent regions at both VT. This implied that tidal recruitment was avoided but end-inspiratory overinflation was present irrespective of VT. In patients, regional CRS differences between low and high VT revealed high degree of tidal recruitment and low overinflation at 3±1 cmH2O PEEP. Tidal recruitment decreased at 10±1 cmH2O and was further reduced at 15±2 cmH2O PEEP. Conclusions Tidal recruitment and end-inspiratory overinflation can be assessed by EIT

  17. PEEP-masks in patients with severe obstructive pulmonary disease: a negative report.

    PubMed

    Christensen, H R; Simonsen, K; Lange, P; Clementsen, P; Kampmann, J P; Viskum, K; Heideby, J; Koch, U

    1990-03-01

    Positive pressure during expiration by face masks applied by the patient has gained wide acceptance in the treatment of chronic bronchitis, but the efficacy is still unproven. The effect of 6 months of treatment with PEEP-masks (positive end-expiratory pressure) was therefore studied in 47 patients with severe irreversible obstructive pulmonary disease (forced expiratory volume in one second (FEV1) about 1 l), and mucus hypersecretion. Patients were double-blindly randomized to at least 45 min daily treatment with PEEP-masks with either 10 or 0 cm water pressure. After 6 months of treatment, no statistical difference was found between the two groups in change of median values (month 6 - month 0) of FEV1, forced vital capacity (FVC), arterial oxygen tension (PaO2), amount of sputum or dyspnoea. Median values of arterial carbon dioxide tension (PaCO2) decreased significantly (0.03 kPa) in the placebo group. Cough intensity and dyspnoea during walking on staircases improved significantly in the placebo group. No difference among groups was found in number of days bedridden, hospitalized, number of exacerbations or antibiotic consumption. We conclude, that the use of PEEP-masks in these patients is without clinical documentation and cannot be recommended.

  18. Effect of PEEP and inhaled nitric oxide on pulmonary gas exchange during gaseous and partial liquid ventilation with small volumes of perfluorocarbon.

    PubMed

    Max, M; Kuhlen, R; Falter, F; Reyle-Hahn, M; Dembinski, R; Rossaint, R

    2000-04-01

    Partial liquid ventilation, positive end-expiratory pressure (PEEP) and inhaled nitric oxide (NO) can improve ventilation/perfusion mismatch in acute lung injury (ALI). The aim of the present study was to compare gas exchange and hemodynamics in experimental ALI during gaseous and partial liquid ventilation at two different levels of PEEP, with and without the inhalation of nitric oxide. Seven pigs (24+/-2 kg BW) were surfactant-depleted by repeated lung lavage with saline. Gas exchange and hemodynamic parameters were assessed in all animals during gaseous and subsequent partial liquid ventilation at two levels of PEEP (5 and 15 cmH2O) and intermittent inhalation of 10 ppm NO. Arterial oxygenation increased significantly with a simultaneous decrease in cardiac output when PEEP 15 cmH2O was applied during gaseous and partial liquid ventilation. All other hemodynamic parameters revealed no relevant changes. Inhalation of NO and instillation of perfluorocarbon had no additive effects on pulmonary gas exchange when compared to PEEP 15 cmH2O alone. In experimental lung injury, improvements in gas exchange are most distinct during mechanical ventilation with PEEP 15 cmH2O without significantly impairing hemodynamics. Partial liquid ventilation and inhaled NO did not cause an additive increase of PaO2.

  19. Multivariable fractional polynomial interaction to investigate continuous effect modifiers in a meta-analysis on higher versus lower PEEP for patients with ARDS.

    PubMed

    Kasenda, Benjamin; Sauerbrei, Willi; Royston, Patrick; Mercat, Alain; Slutsky, Arthur S; Cook, Deborah; Guyatt, Gordon H; Brochard, Laurent; Richard, Jean-Christophe M; Stewart, Thomas E; Meade, Maureen; Briel, Matthias

    2016-09-08

    A recent individual patient data (IPD) meta-analysis suggested that patients with moderate or severe acute respiratory distress syndrome (ARDS) benefit from higher positive end-expiratory pressure (PEEP) ventilation strategies. However, thresholds for continuous variables (eg, hypoxaemia) are often arbitrary and linearity assumptions in regression approaches may not hold; the multivariable fractional polynomial interaction (MFPI) approach can address both problems. The objective of this study was to apply the MFPI approach to investigate interactions between four continuous patient baseline variables and higher versus lower PEEP on clinical outcomes. Pooled data from three randomised trials in intensive care identified by a systematic review. 2299 patients with acute lung injury requiring mechanical ventilation. Higher (N=1136) versus lower PEEP (N=1163) ventilation strategy. Prespecified outcomes included mortality, time to death and time-to-unassisted breathing. We examined the following continuous baseline characteristics as potential effect modifiers using MFPI: PaO2/FiO2 (arterial partial oxygen pressure/ fraction of inspired oxygen), oxygenation index, respiratory system compliance (tidal volume/(inspiratory plateau pressure-PEEP)) and body mass index (BMI). We found that for patients with PaO2/FiO2 below 150 mm Hg, but above 100 mm Hg or an oxygenation index above 12 (moderate ARDS), higher PEEP reduces hospital mortality, but the beneficial effect appears to level off for patients with very severe ARDS. Patients with mild ARDS (PaO2/FiO2 above 200 mm Hg or an oxygenation index below 10) do not seem to benefit from higher PEEP and might even be harmed. For patients with a respiratory system compliance above 40 mL/cm H2O or patients with a BMI above 35 kg/m(2), we found a trend towards reduced mortality with higher PEEP, but there is very weak statistical confidence in these findings. MFPI analyses suggest a nonlinear effect modification of

  20. Effects of peep on lung injury, pulmonary function, systemic circulation and mortality in animals with uninjured lungs—a systematic review

    PubMed Central

    Pisani, Luigi; Chaves, Renato Carneiro de Freitas; Amorim, Thiago Chaves; Cherpanath, Thomas; Determann, Rogier; Dongelmans, Dave A.; Paulus, Frederique; Tuinman, Pieter Roel; Pelosi, Paolo; Gama de Abreu, Marcelo; Schultz, Marcus J.; Serpa Neto, Ary

    2018-01-01

    It is well-known that positive end-expiratory pressure (PEEP) can prevent ventilator-induced lung injury (VILI) and improve pulmonary physiology in animals with injured lungs. It’s uncertain whether PEEP has similar effects in animals with uninjured lungs. A systematic review of randomized controlled trials (RCTs) comparing different PEEP levels in animals with uninjured lungs was performed. Trials in animals with injured lungs were excluded, as were trials that compared ventilation strategies that also differed with respect to other ventilation settings, e.g., tidal volume size. The search identified ten eligible trials in 284 animals, including rodents and small as well as large mammals. Duration of ventilation was highly variable, from 1 to 6 hours and tidal volume size varied from 7 to 60 mL/kg. PEEP ranged from 3 to 20 cmH2O, and from 0 to 5 cmH2O, in the ‘high PEEP’ or ‘PEEP’ arms, and in the ‘low PEEP’ or ‘no PEEP’ arms, respectively. Definitions used for lung injury were quite diverse, as were other outcome measures. The effects of PEEP, at any level, on lung injury was not straightforward, with some trials showing less injury with ‘high PEEP’ or ‘PEEP’ and other trials showing no benefit. In most trials, ‘high PEEP’ or ‘PEEP’ was associated with improved respiratory system compliance, and better oxygen parameters. However, ‘high PEEP’ or ‘PEEP’ was also associated with occurrence of hypotension, a reduction in cardiac output, or development of hyperlactatemia. There were no differences in mortality. The number of trials comparing ‘high PEEP’ or ‘PEEP’ with ‘low PEEP’ or ‘no PEEP’ in animals with uninjured lungs is limited, and results are difficult to compare. Based on findings of this systematic review it’s uncertain whether PEEP, at any level, truly prevents lung injury, while most trials suggest potential harmful effects on the systemic circulation. PMID:29430442

  1. [POSITIVE END-EXPIRATORY PRESSURE (PEEP) INFLUENCES ON INTRACRANIAL PRESSURE, SYSTEMIC HEMODYNAMICS AND PULMONARY GAS EXCHANGE IN PATIENTS WITH INTRACRANIAl HEMORRHAGE IN CRITICAL STATE].

    PubMed

    Solodov, A A; Petrikov, S S; Krylov, V V

    2016-01-01

    Positive end-expiratory pressure is one of the main parameters of respiratory support influencing the gas exchange. However, despite the number ofpositive effects, PEEP can compromise venous outflow from the cranial cavity, increased intracranial pressure, decreased venous return and cardiac output and, consequently, reduced blood pressure and cerebral perfusion. The article presents the results of a survey of 39 patients with intracranial hemorrhage in critical state, undergoing respiratory support with different levels of positive end-expiratory pressure. Increasing of PEEP to 15 cm H2O had no adverse effect on mean arterial pressure, heart rate and cerebral perfusion pressure and led only to an clinical insignificant increase (maximum on 2.4 +/- 5.1 mmHg) in intracranial pressure. The greatest hemodynamic changes were observed with increasing PEEP up to 20 cm H2O in patients with preserved compliance ofthe respiratory system. The instability of cerebral perfusion and intracranial pressure associated with a decrease in cardiac output and preload and the exhaustion of compensatory mechanism of peripheral vascular resistance. High levels of PEEP despite the trend towards Cstat reduction will not lead to an increase in the content of extravascular lung water Thus a gradual increase of PEEP to 15 cm H2O can be safe and effective method of improving pulmonary gas exchange in patients with intracranial hemorrhage in critical state.

  2. Performance of different PEEP valves and helmet outlets at increasing gas flow rates: a bench top study.

    PubMed

    Isgrò, S; Zanella, A; Giani, M; Abd El Aziz El Sayed Deab, S; Pesenti, A; Patroniti, N

    2012-10-01

    Aim of the paper was to assess the performance of different expiratory valves and the resistance of helmet outlet ports at increasing gas flow rates. A gas flow-meter was connected to 10 different expiratory peep valves: 1 water-seal valve, 4 precalibrated fixed PEEP valves and 5 adjustable PEEP valves. Three new valves of each brand, set at different pressure levels (5-7.5-10-12.5-15 cmH(2)O, if available), were tested at increasing gas flow rates (from 30 to 150 L/min). We measured the pressure generated just before the valves. Three different helmets sealed on a mock head were connected at the inlet port with a gas flow-meter while the outlet was left clear. We measured the pressure generated inside the helmet (due to the flow-resistance of the outlet port) at increasing gas flow rates. Adjustable valves showed a variable degree flow-dependency (increasing difference between the measured and the expected pressure at increasing flow rates), while pre-calibrated valves revealed a flow-independent behavior. Water seal valve showed low degree flow-dependency. The pressures generated by the outlet port of the tested helmets ranged from 0.02 to 2.29 cmH(2)O at the highest gas flow rate. Adjustable PEEP valves are not suggested for continuous-flow CPAP systems as their flow-dependency can lead to pressures higher than expected. Precalibrated and water seal valves exhibit the best performance. Different helmet outlet ports do not significantly affect the pressure generated during helmet CPAP. In order to avoid iatrogenic complications gas flow and pressure delivered during helmet CPAP must always be monitored.

  3. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    PubMed

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  4. Monitoring of intratidal lung mechanics: a Graphical User Interface for a model-based decision support system for PEEP-titration in mechanical ventilation.

    PubMed

    Buehler, S; Lozano-Zahonero, S; Schumann, S; Guttmann, J

    2014-12-01

    In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension should be avoided. Classic approaches of analyzing static respiratory system mechanics fail in particular if lung injury already prevails. A new approach of analyzing dynamic respiratory system mechanics to set PEEP uses the intratidal, volume-dependent compliance which is believed to stay relatively constant during one breath only if neither atelectasis nor overdistension occurs. To test the success of this dynamic approach systematically at bedside or in an animal study, automation of the computing steps is necessary. A decision support system for optimizing PEEP in form of a Graphical User Interface (GUI) was targeted. Respiratory system mechanics were analyzed using the gliding SLICE method. The resulting shapes of the intratidal compliance-volume curve were classified into one of six categories, each associated with a PEEP-suggestion. The GUI should include a graphical representation of the results as well as a quality check to judge the reliability of the suggestion. The implementation of a user-friendly GUI was successfully realized. The agreement between modelled and measured pressure data [expressed as root-mean-square (RMS)] tested during the implementation phase with real respiratory data from two patient studies was below 0.2 mbar for data taken in volume controlled mode and below 0.4 mbar for data taken in pressure controlled mode except for two cases with RMS < 0.6 mbar. Visual inspections showed, that good and medium quality data could be reliably identified. The new GUI allows visualization of intratidal compliance-volume curves on a breath-by-breath basis. The automatic categorisation of curve shape into one of six shape

  5. Advances in the continuous monitoring of erosion and deposition dynamics: Developments and applications of the new PEEP-3T system

    NASA Astrophysics Data System (ADS)

    Lawler, D. M.

    2008-01-01

    In most episodic erosion and deposition systems, knowledge of the timing of geomorphological change, in relation to fluctuations in the driving forces, is crucial to strong erosion process inference, and model building, validation and development. A challenge for geomorphology, however, is that few studies have focused on geomorphological event structure (timing, magnitude, frequency and duration of individual erosion and deposition events), in relation to applied stresses, because of the absence of key monitoring methodologies. This paper therefore (a) presents full details of a new erosion and deposition measurement system — PEEP-3T — developed from the Photo-Electronic Erosion Pin sensor in five key areas, including the addition of nocturnal monitoring through the integration of the Thermal Consonance Timing (TCT) concept, to produce a continuous sensing system; (b) presents novel high-resolution datasets from the redesigned PEEP-3T system for river bank system of the Rivers Nidd and Wharfe, northern England, UK; and (c) comments on their potential for wider application throughout geomorphology to address these key measurement challenges. Relative to manual methods of erosion and deposition quantification, continuous PEEP-3T methodologies increase the temporal resolution of erosion/deposition event detection by more than three orders of magnitude (better than 1-second resolution if required), and this facility can significantly enhance process inference. Results show that river banks are highly dynamic thermally and respond quickly to radiation inputs. Data on bank retreat timing, fixed with PEEP-3T TCT evidence, confirmed that they were significantly delayed up to 55 h after flood peaks. One event occurred 13 h after emergence from the flow. This suggests that mass failure processes rather than fluid entrainment dominated the system. It is also shown how, by integrating turbidity instrumentation with TCT ideas, linkages between sediment supply and sediment

  6. Minimizing atelectasis formation during general anaesthesia—oxygen washout is a non-essential supplement to PEEP

    PubMed Central

    Östberg, Erland; Auner, Udo; Enlund, Mats; Zetterström, Henrik; Edmark, Lennart

    2017-01-01

    Background Following preoxygenation and induction of anaesthesia, most patients develop atelectasis. We hypothesized that an immediate restoration to a low oxygen level in the alveoli would prevent atelectasis formation and improve oxygenation during the ensuing anaesthesia. Methods We randomly assigned 24 patients to either a control group (n = 12) or an intervention group (n = 12) receiving an oxygen washout procedure directly after intubation. Both groups were, depending on body mass index, ventilated with a positive end-expiratory pressure (PEEP) of 6–8 cmH2O during surgery. The atelectasis area was studied by computed tomography before emergence. Oxygenation levels were evaluated by measuring blood gases and calculating estimated venous admixture (EVA). Results The atelectasis areas expressed as percentages of the total lung area were 2.0 (1.5–2.7) (median [interquartile range]) and 1.8 (1.4–3.3) in the intervention and control groups, respectively. The difference was non-significant, and also oxygenation was similar between the two groups. Compared to oxygenation before the start of anaesthesia, oxygenation at the end of surgery was improved in the intervention group, mean (SD) EVA from 7.6% (6.6%) to 3.9% (2.9%) (P = .019) and preserved in the control group, mean (SD) EVA from 5.0% (5.3%) to 5.6% (7.1%) (P = .59). Conclusion Although the oxygen washout restored a low pulmonary oxygen level within minutes, it did not further reduce atelectasis size. Both study groups had small atelectasis and good oxygenation. These results suggest that a moderate PEEP alone is sufficient to minimize atelectasis and maintain oxygenation in healthy patients. PMID:28434271

  7. Minimizing atelectasis formation during general anaesthesia-oxygen washout is a non-essential supplement to PEEP.

    PubMed

    Östberg, Erland; Auner, Udo; Enlund, Mats; Zetterström, Henrik; Edmark, Lennart

    2017-06-01

    Following preoxygenation and induction of anaesthesia, most patients develop atelectasis. We hypothesized that an immediate restoration to a low oxygen level in the alveoli would prevent atelectasis formation and improve oxygenation during the ensuing anaesthesia. We randomly assigned 24 patients to either a control group (n = 12) or an intervention group (n = 12) receiving an oxygen washout procedure directly after intubation. Both groups were, depending on body mass index, ventilated with a positive end-expiratory pressure (PEEP) of 6-8 cmH 2 O during surgery. The atelectasis area was studied by computed tomography before emergence. Oxygenation levels were evaluated by measuring blood gases and calculating estimated venous admixture (EVA). The atelectasis areas expressed as percentages of the total lung area were 2.0 (1.5-2.7) (median [interquartile range]) and 1.8 (1.4-3.3) in the intervention and control groups, respectively. The difference was non-significant, and also oxygenation was similar between the two groups. Compared to oxygenation before the start of anaesthesia, oxygenation at the end of surgery was improved in the intervention group, mean (SD) EVA from 7.6% (6.6%) to 3.9% (2.9%) (P = .019) and preserved in the control group, mean (SD) EVA from 5.0% (5.3%) to 5.6% (7.1%) (P = .59). Although the oxygen washout restored a low pulmonary oxygen level within minutes, it did not further reduce atelectasis size. Both study groups had small atelectasis and good oxygenation. These results suggest that a moderate PEEP alone is sufficient to minimize atelectasis and maintain oxygenation in healthy patients.

  8. Risk stratification using SpO2/FiO2 and PEEP at initial ARDS diagnosis and after 24 h in patients with moderate or severe ARDS.

    PubMed

    Pisani, Luigi; Roozeman, Jan-Paul; Simonis, Fabienne D; Giangregorio, Antonio; van der Hoeven, Sophia M; Schouten, Laura R; Horn, Janneke; Neto, Ary Serpa; Festic, Emir; Dondorp, Arjen M; Grasso, Salvatore; Bos, Lieuwe D; Schultz, Marcus J

    2017-10-25

    We assessed the potential of risk stratification of ARDS patients using SpO 2 /FiO 2 and positive end-expiratory pressure (PEEP) at ARDS onset and after 24 h. We used data from a prospective observational study in patients admitted to a mixed medical-surgical intensive care unit of a university hospital in the Netherlands. Risk stratification was by cutoffs for SpO 2 /FiO 2 and PEEP. The primary outcome was in-hospital mortality. Patients with moderate or severe ARDS with a length of stay of > 24 h were included in this study. Patients were assigned to four predefined risk groups: group I (SpO 2 /FiO 2  ≥ 190 and PEEP < 10 cm H 2 O), group II (SpO 2 /FiO 2  ≥ 190 and PEEP ≥ 10 cm), group III (SpO 2 /FiO 2  < 190 and PEEP < 10 cm H 2 O) and group IV (SpO 2 /FiO 2  < 190 and PEEP ≥ 10 cm H 2 O). The analysis included 456 patients. SpO 2 /FiO 2 and PaO 2 /FiO 2 had a strong relationship (P < 0.001, R 2  = 0.676) that could be described in a linear regression equation (SpO 2 /FiO 2  = 42.6 + 1.0 * PaO 2 /FiO 2 ). Risk stratification at initial ARDS diagnosis resulted in groups that had no differences in in-hospital mortality. Risk stratification at 24 h resulted in groups with increasing mortality rates. The association between group assignment at 24 h and outcome was confounded by several factors, including APACHE IV scores, arterial pH and plasma lactate levels, and vasopressor therapy. In this cohort of patients with moderate or severe ARDS, SpO 2 /FiO 2 and PaO 2 /FiO 2 have a strong linear relationship. In contrast to risk stratification at initial ARDS diagnosis, risk stratification using SpO 2 /FiO 2 and PEEP after 24 h resulted in groups with worsening outcomes. Risk stratification using SpO 2 /FiO 2 and PEEP could be practical, especially in resource-limited settings.

  9. Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.

    PubMed

    Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A

    1994-11-01

    To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p < .05). The cardiac output reduction induced by PEEP = auto-PEEP + 5 was > 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle

  10. Positive end expiratory pressure in acute hypoxemic respiratory failure due to community acquired pneumonia: do we need a personalized approach?

    PubMed Central

    Paolini, Valentina; Faverio, Paola; Aliberti, Stefano; Messinesi, Grazia; Foti, Giuseppe; Sibila, Oriol; Monzani, Anna; Stainer, Anna; Pesci, Alberto

    2018-01-01

    Background Acute respiratory failure (ARF) is a life-threatening complication in patients with community acquired pneumonia (CAP). The use of non-invasive ventilation is controversial. With this prospective, observational study we aimed to describe a protocol to assess whether a patient with moderate-to-severe hypoxemic ARF secondary to CAP benefits, in clinical and laboratoristic terms, from the application of a positive end expiratory pressure (PEEP) + oxygen vs oxygen alone. Methods Patients who benefit from PEEP application (PEEP-responders) were defined as those with partial pressure of arterial oxygen to the fraction of inspired oxygen (PaO2/FiO2) increase >20% and/or reduction of respiratory distress during PEEP + oxygen therapy compared to oxygen therapy alone. Clinical characteristics and outcomes were compared between PEEP-responders and PEEP-non responders. Results Out of 41 patients, 27 (66%) benefit from PEEP application (PEEP-responders), the best response was obtained with a PEEP of 10 cmH2O in 13 patients, 7.5 cmH2O in eight and 5 cmH2O in six. PEEP-responders were less likely to present comorbidities compared to PEEP-non responders. No differences between groups were found in regards to endotracheal intubation criteria fullfillment, intensive care unit admission and in-hospital mortality, while PEEP-responders had a shorter length of hospital stay. Discussion The application of a protocol to evaluate PEEP responsiveness might be useful in patients with moderate-to-severe hypoxemic ARF due to CAP in order to personalize and maximize the effectiveness of therapy, and prevent the inappropriate PEEP use. PEEP responsiveness does not seem to be associated with better outcomes, with the exception of a shorter length of hospital stay. PMID:29404202

  11. Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

    PubMed

    Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio

    2014-09-01

    Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

  12. Positive end-expiratory pressure during resuscitation at birth in very-low birth weight infants: A randomized-controlled pilot trial.

    PubMed

    Kitsommart, Ratchada; Nakornchai, Kittaya; Yangthara, Buranee; Jiraprasertwong, Ratchada; Paes, Bosco

    2017-12-09

    There is limited evidence of the effect of positive end-expiratory pressure (PEEP) during resuscitation soon after birth. Premature neonates may experience respiratory distress from surfactant insufficiency and providing PEEP after the very first breath, may improve outcomes following appropriate resuscitation. The objective of this study was to evaluate the short term respiratory outcomes after positive pressure ventilation (PPV) with PEEP in preterm infants at birth. A prospective randomized-controlled, pilot trial was conducted. Premature neonates ≤ 32 weeks gestational age or birth weight < 1500 g were recruited. Subjects were allocated to either PEEP of 5 cm H 2 O (PEEP-5) or no PEEP (PEEP-0) if PPV was administered. Pre-ductal, peripheral capillary oxygen saturation (SpO 2 ) and fraction of inspired oxygen concentration (FiO 2 ) were monitored at 1, 3, 5, 10, 15, and 20 min after birth. FiO 2 was adjusted to achieve targeted SpO 2 using the 2010 neonatal resuscitation protocol guidelines. 56% (14/25; PEEP-0) and 50% (13/26; PEEP-5) infants received PPV. Mean gestational age was 30 (PEEP-0) vs 31 (PEEP-5) weeks. The mean [SD] birthweight (g) of PEEP-0 was significantly lower than PEEP-5 (1050.4 [262.7] vs 1218.8 [236.8], p = 0.02). Pre-ductal SpO 2, FiO 2 delivered at each time point, and rates of pneumothorax, surfactant administration and oxygen dependency at 36 weeks postmenstrual age or death was similar. Due to the small sample size and potential bias accrued through random allocation of higher birthweight infants to the PEEP-5 group, the results did not confirm differences in outcomes between the groups, despite evidence favoring postnatal ventilation with PEEP. A further randomized, controlled clinical trial with a larger sample size is warranted to determine the utility and safety of PEEP during the resuscitation of premature infants immediately after birth. Copyright © 2017. Published by Elsevier B.V.

  13. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    PubMed

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  14. Intratidal recruitment/derecruitment persists at low and moderate positive end-expiratory pressure in paediatric patients.

    PubMed

    Wirth, Steffen; Artner, Lisa; Broß, Tobias; Lozano-Zahonero, Sara; Spaeth, Johannes; Schumann, Stefan

    2016-12-01

    In paediatric patients positive end-expiratory pressure (PEEP) is traditionally set lower than in adults. We investigated whether moderately higher PEEP improves respiratory mechanics and regional ventilation. Therefore, 40 children were mechanically ventilated with PEEP 2 and 5cmH 2 O. Volume-dependent compliance profiles were analysed as a measure of intratidal recruitment/derecruitment. Regional ventilation was assessed using electrical impedance tomography. Mean compliance was 17.9±9.9mLcmH 2 O -1 (PEEP 2cmH 2 O), and 19.0±10.9mLcmH 2 O -1 (PEEP 5 cmH 2 O, p<0.001). Strong intratidal recruitment/derecruitment occurred in 40% of children at PEEP 2 cmH 2 O, and 36% at PEEP 5 cmH 2 O. Children showing strong recruitment/derecruitment were 33 (PEEP 2 cmH 2 0) and 20 (PEEP 5 cmH 2 0) months younger than children showing moderate recruitment/derecruitment. A higher PEEP improved peripheral ventilation. In conclusion, mechanically ventilated paediatric patients undergo intratidal recruitment/derecruitment which occurs more prominently in younger than in older children. A PEEP of 5cmH 2 O does not fully prevent intratidal recruitment/derecruitment but homogenizes regional ventilation in comparison to 2cmH 2 O. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Alveolar Tidal recruitment/derecruitment and Overdistension During Four Levels of End-Expiratory Pressure with Protective Tidal Volume During Anesthesia in a Murine Lung-Healthy Model.

    PubMed

    Soares, Joao Henrique Neves; Carvalho, Alysson Roncally; Bergamini, Bruno Curty; Gress, Maria Alice Kuster; Jandre, Frederico Caetano; Zin, Walter Araujo; Giannella-Neto, Antonio

    2018-06-01

    We compared respiratory mechanics between the positive end-expiratory pressure of minimal respiratory system elastance (PEEP minErs ) and three levels of PEEP during low-tidal-volume (6 mL/kg) ventilation in rats. Twenty-four rats were anesthetized, paralyzed, and mechanically ventilated. Airway pressure (P aw ), flow (F), and volume (V) were fitted by a linear single compartment model (LSCM) P aw (t) = E rs  × V(t) + R rs  × F(t) + PEEP or a volume- and flow-dependent SCM (VFDSCM) P aw (t) = (E 1  + E 2  × V(t)) × V(t) + (K 1  + K 2  × |F(t)|) × F(t) + PEEP, where E rs and R rs are respiratory system elastance and resistance, respectively; E 1 and E 2 × V are volume-independent and volume-dependent E rs , respectively; and K 1 and K 2  × F are flow-independent and flow-dependent R rs , respectively. Animals were ventilated for 1 h at PEEP 0 cmH 2 O (ZEEP); PEEP minErs ; 2 cmH 2 O above PEEP minErs (PEEP minErs+2 ); or 4 cmH 2 O above PEEP minErs (PEEP minErs+4 ). Alveolar tidal recruitment/derecruitment and overdistension were assessed by the index %E 2  = 100 × [(E 2  × V T )/(E 1  + |E 2 | × V T )], and alveolar stability by the slope of E rs (t). %E 2 varied between 0 and 30% at PEEP minErs in most respiratory cycles. Alveolar Tidal recruitment/derecruitment (%E 2  < 0) and overdistension (%E 2  > 30) were predominant in the absence of PEEP and in PEEP levels higher than PEEP minErs , respectively. The slope of E rs (t) was different from zero in all groups besides PEEP minErs+4 . PEEP minErs presented the best compromise between alveolar tidal recruitment/derecruitment and overdistension, during 1 h of low-V T mechanical ventilation.

  16. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

    PubMed

    Spadaro, Savino; Mauri, Tommaso; Böhm, Stephan H; Scaramuzzo, Gaetano; Turrini, Cecilia; Waldmann, Andreas D; Ragazzi, Riccardo; Pesenti, Antonio; Volta, Carlo Alberto

    2018-01-31

    Assessing alveolar recruitment at different positive end-expiratory pressure (PEEP) levels is a major clinical and research interest because protective ventilation implies opening the lung without inducing overdistention. The pressure-volume (P-V) curve is a validated method of assessing recruitment but reflects global characteristics, and changes at the regional level may remain undetected. The aim of the present study was to compare, in intubated patients with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS), lung recruitment measured by P-V curve analysis, with dynamic changes in poorly ventilated units of the dorsal lung (dependent silent spaces [DSSs]) assessed by electrical impedance tomography (EIT). We hypothesized that DSSs might represent a dynamic bedside measure of recruitment. We carried out a prospective interventional study of 14 patients with AHRF and ARDS admitted to the intensive care unit undergoing mechanical ventilation. Each patient underwent an incremental/decremental PEEP trial that included five consecutive phases: PEEP 5 and 10 cmH 2 O, recruitment maneuver + PEEP 15 cmH 2 O, then PEEP 10 and 5 cmH 2 O again. We measured, at the end of each phase, recruitment from previous PEEP using the P-V curve method, and changes in DSS were continuously monitored by EIT. PEEP changes induced alveolar recruitment as assessed by the P-V curve method and changes in the amount of DSS (p < 0.001). Recruited volume measured by the P-V curves significantly correlated with the change in DSS (r s  = 0.734, p < 0.001). Regional compliance of the dependent lung increased significantly with rising PEEP (median PEEP 5 cmH 2 O = 11.9 [IQR 10.4-16.7] ml/cmH 2 O, PEEP 15 cmH 2 O = 19.1 [14.2-21.3] ml/cmH 2 O; p < 0.001), whereas regional compliance of the nondependent lung decreased from PEEP 5 cmH 2 O to PEEP 15 cmH 2 O (PEEP 5 cmH 2 O = 25.3 [21.3-30.4] ml/cmH 2 O, PEEP 15 cmH 2 O = 20

  17. Impact of Different Ventilation Strategies on Driving Pressure, Mechanical Power, and Biological Markers During Open Abdominal Surgery in Rats.

    PubMed

    Maia, Lígia de A; Samary, Cynthia S; Oliveira, Milena V; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Morales, Marcelo M; Schultz, Marcus J; Abreu, Marcelo G; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia Rieken Macedo

    2017-10-01

    Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (ΔPRS), mechanical power, and lung damage in a model of open abdominal surgery. Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM-), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM-), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM- and high VT/low PEEP/RM-, resulted in lower ΔPRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; P< .001) and less mechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM- (P = .03). E-cadherin expression

  18. Positive end-expiratory pressure at minimal respiratory elastance represents the best compromise between mechanical stress and lung aeration in oleic acid induced lung injury.

    PubMed

    Carvalho, Alysson Roncally S; Jandre, Frederico C; Pino, Alexandre V; Bozza, Fernando A; Salluh, Jorge; Rodrigues, Rosana; Ascoli, Fabio O; Giannella-Neto, Antonio

    2007-01-01

    Protective ventilatory strategies have been applied to prevent ventilator-induced lung injury in patients with acute lung injury (ALI). However, adjustment of positive end-expiratory pressure (PEEP) to avoid alveolar de-recruitment and hyperinflation remains difficult. An alternative is to set the PEEP based on minimizing respiratory system elastance (Ers) by titrating PEEP. In the present study we evaluate the distribution of lung aeration (assessed using computed tomography scanning) and the behaviour of Ers in a porcine model of ALI, during a descending PEEP titration manoeuvre with a protective low tidal volume. PEEP titration (from 26 to 0 cmH2O, with a tidal volume of 6 to 7 ml/kg) was performed, following a recruitment manoeuvre. At each PEEP, helical computed tomography scans of juxta-diaphragmatic parts of the lower lobes were obtained during end-expiratory and end-inspiratory pauses in six piglets with ALI induced by oleic acid. The distribution of the lung compartments (hyperinflated, normally aerated, poorly aerated and non-aerated areas) was determined and the Ers was estimated on a breath-by-breath basis from the equation of motion of the respiratory system using the least-squares method. Progressive reduction in PEEP from 26 cmH2O to the PEEP at which the minimum Ers was observed improved poorly aerated areas, with a proportional reduction in hyperinflated areas. Also, the distribution of normally aerated areas remained steady over this interval, with no changes in non-aerated areas. The PEEP at which minimal Ers occurred corresponded to the greatest amount of normally aerated areas, with lesser hyperinflated, and poorly and non-aerated areas. Levels of PEEP below that at which minimal Ers was observed increased poorly and non-aerated areas, with concomitant reductions in normally inflated and hyperinflated areas. The PEEP at which minimal Ers occurred, obtained by descending PEEP titration with a protective low tidal volume, corresponded to the

  19. OPTIMUM LEVEL OF POSITIVE END-EXPIRATORY PRESSURE IN ACUTE RESPIRATORY DISTRESS SYNDROME CAUSED BY INFLUENZA A(H1NI)PDM09: BALANCE BETWEEN MAXIMAL END-EXPIRATORY VOLUME AND MINIMAL ALVEOLAR OVERDISTENSION.

    PubMed

    Yaroshetskiym A I; Protsenko, D N; Boytsov, P V; Chentsov, V B; Nistratov, S L; Kudlyakov, O N; Solov'ev, V V; Banova, Zh I; Shkuratova, N V; Rezenov, N A; Gel'fand, B R

    2016-11-01

    to determine optimum level ofpositive end-expiratory pressure (PEEP) according to balance between maxi- mal end-expiratory lung volume (EEL V)(more than predicted) and minimal decrease in exhaled carbon dioxide volume (VCO) and then to develop the algorithm of gas exchange correction based on prognostic values of EEL K; alveolar recruitability, PA/FiO2, static compliance (C,,,) and VCO2. 27 mechanically ventilatedpatients with acute respiratory distress syndrome (ARDS) caused by influenza A (HINJ)pdm09 in Moscow Municipal Clinics ICU's from January to March 2016 were included in the trial. At the beginning of the study patients had the following characteristic: duration offlu symptoms 5 (3-10) days, p.0/FiO2 120 (70-50) mmHg. SOFA 7 (5-9), body mass index 30.1 (26.4-33.8) kg/m², static compliance of respiratory system 35 (30-40) ml/mbar: Under sedation and paralysis we measured EELV, C VCO and end-tidal carbon dioxide concentration (EtCO) (for CO₂ measurements we fixed short-term values after 2 min after PEEP level change) at PEEP 8, 11,13,15,18, 20 mbar consequently, and incase of good recruitability, at 22 and 24 mbar. After analyses of obtained data we determined PEEP value in which increase in EELV was maximal (more than predicted) and depression of VCO₂ was less than 20%, change in mean blood pressure and heart rate were both less than 20% (measured at PEEP 8 mbar). After that we set thus determined level of PEEP and didn't change it for 5 days. Comparision of predicted and measured EELV revealed two typical points of alveloar recruiment: the first at PEEP 11-15 mbar, the second at PEEP 20-22 mbar. EELV measured at PEEP 18 mbar appeared to be higher than predicted at PEEP 8 mbar by 400 ml (approx.), which was the sign of alveolar recruitment-1536 (1020-1845) ml vs 1955 (1360-2320) ml, p=0,001, Friedman test). we didn't found significant changes of VCO₂ when increased PEEP in the range from 8 to 15 mbar (p>0.05, Friedman test). PEEP increase from 15 to

  20. Setting individualized positive end-expiratory pressure level with a positive end-expiratory pressure decrement trial after a recruitment maneuver improves oxygenation and lung mechanics during one-lung ventilation.

    PubMed

    Ferrando, Carlos; Mugarra, Ana; Gutierrez, Andrea; Carbonell, Jose Antonio; García, Marisa; Soro, Marina; Tusman, Gerardo; Belda, Francisco Javier

    2014-03-01

    We investigated whether individualized positive end-expiratory pressure (PEEP) improves oxygenation, ventilation, and lung mechanics during one-lung ventilation compared with standardized PEEP. Thirty patients undergoing thoracic surgery were randomly allocated to the study or control group. Both groups received an alveolar recruitment maneuver at the beginning and end of one-lung ventilation. After the alveolar recruitment maneuver, the control group had their lungs ventilated with a 5 cm·H2O PEEP, while the study group had their lungs ventilated with an individualized PEEP level determined by a PEEP decrement trial. Arterial blood samples, lung mechanics, and volumetric capnography were recorded at multiple timepoints throughout the procedure. The individualized PEEP values in study group were higher than the standardized PEEP values (10 ± 2 vs 5 cm·H2O; P < 0.001). In both groups, arterial oxygenation decreased when bilateral-lung ventilation was switched to one-lung ventilation and increased after the alveolar recruitment maneuver. During one-lung ventilation, oxygenation was maintained in the study group but decreased in the control group. After one-lung ventilation, arterial oxygenation was significantly higher in the study group (306 vs 231 mm·Hg, P = 0.007). Static compliance decreased in both groups when bilateral-lung ventilation was switched to one-lung ventilation. Static compliance increased significantly only in the study group (P < 0.001) after the alveolar recruitment maneuver and optimal PEEP adjustment. The alveolar recruitment maneuver did not decrease cardiac index in any patient. During one-lung ventilation, the improvements in oxygenation and lung mechanics after an alveolar recruitment maneuver were better preserved by ventilation by using individualized PEEP with a PEEP decrement trial than with a standardized 5 cm·H2O of PEEP.

  1. Neonatal Pneumothorax Pressures Surpass Higher Threshold in Lung Recruitment Maneuvers: An In Vivo Interventional Study.

    PubMed

    González-Pizarro, Patricio; García-Fernández, Javier; Canfrán, Susana; Gilsanz, Fernando

    2016-02-01

    Causing pneumothorax is one of the main concerns of lung recruitment maneuvers in pediatric patients, especially newborns. Therefore, these maneuvers are not performed routinely during anesthesia. Our objective was to determine the pressures that cause pneumothorax in healthy newborns by a prospective experimental study of 10 newborn piglets (<48 h old) with healthy lungs under general anesthesia. The primary outcome was peak inspiratory pressure (PIP) causing pneumothorax. Animals under anesthesia and bilateral chest tube catheterization were randomly allocated to 2 groups: one with PEEP and fixed inspiratory driving pressure of 15 cm H2O (PEEP group) and the second one with PEEP = 0 cm H2O and non-fixed inspiratory driving pressure (zero PEEP group). In both groups, the ventilation mode was pressure-controlled, and PIP was raised at 2-min intervals, with steps of 5 cm H2O until air leak was observed through the chest tubes. The PEEP group raised PIP through 5-cm H2O PEEP increments, and the zero PEEP group raised PIP through 5-cm H2O inspiratory driving pressure increments. Pneumothorax was observed with a PIP of 90.5 ± 15.7 cm H2O with no statistically significant differences between the PEEP group (92 ± 14.8 cm H2O) and the zero PEEP group (89 ± 18.2 cm H2O). The zero PEEP group had hypotension, with a PIP of 35 cm H2O; the PEEP group had hypotension, with a PIP of 60 cm H2O (P = .01). The zero PEEP group presented bradycardia, with PIP of 40 cm H2O; the PEEP group presented bradycardia, with PIP of 70 cm H2O (P = .002). Performing recruitment maneuvers in newborns without lung disease is a safe procedure in terms of pneumothorax. Pneumothorax does not seem to occur in the clinically relevant PIPs of <50 cm H2O. Hemodynamic impairment may occur with high driving pressures. More studies are needed to determine the exact hemodynamic impact of these procedures and pneumothorax PIP in poorly compliant lungs. Copyright © 2016 by Daedalus Enterprises.

  2. Lung ventilation strategies for acute respiratory distress syndrome: a systematic review and network meta-analysis

    PubMed Central

    Wang, Changsong; Wang, Xiaoyang; Chi, Chunjie; Guo, Libo; Guo, Lei; Zhao, Nana; Wang, Weiwei; Pi, Xin; Sun, Bo; Lian, Ailing; Shi, Jinghui; Li, Enyou

    2016-01-01

    To identify the best lung ventilation strategy for acute respiratory distress syndrome (ARDS), we performed a network meta-analysis. The Cochrane Central Register of Controlled Trials, EMBASE, MEDLINE, CINAHL, and the Web of Science were searched, and 36 eligible articles were included. Compared with higher tidal volumes with FiO2-guided lower positive end-expiratory pressure [PEEP], the hazard ratios (HRs) for mortality were 0.624 (95% confidence interval (CI) 0.419–0.98) for lower tidal volumes with FiO2-guided lower PEEP and prone positioning and 0.572 (0.34–0.968) for pressure-controlled ventilation with FiO2-guided lower PEEP. Lower tidal volumes with FiO2-guided higher PEEP and prone positioning had the greatest potential to reduce mortality, and the possibility of receiving the first ranking was 61.6%. Permissive hypercapnia, recruitment maneuver, and low airway pressures were most likely to be the worst in terms of all-cause mortality. Compared with higher tidal volumes with FiO2-guided lower PEEP, pressure-controlled ventilation with FiO2-guided lower PEEP and lower tidal volumes with FiO2-guided lower PEEP and prone positioning ventilation are associated with lower mortality in ARDS patients. Lower tidal volumes with FiO2-guided higher PEEP and prone positioning ventilation and lower tidal volumes with pressure-volume (P–V) static curve-guided individual PEEP are potential optimal strategies for ARDS patients. PMID:26955891

  3. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial.

    PubMed

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N T; Schultz, Marcus J; Pelosi, Paolo; Kaczka, David W; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications when compared to low PEEP (0-2 cm H2O) approach without recruitment breaths. However, effects of intraoperative PEEP on lung compliance remain poorly understood. We hypothesized that higher PEEP leads to a dominance of intratidal overdistension, whereas lower PEEP results in intratidal recruitment/derecruitment (R/D). To test our hypothesis, we used the volume-dependent elastance index %E2, a respiratory parameter that allows for noninvasive and radiation-free assessment of dominant overdistension and intratidal R/D. We compared the incidence of intratidal R/D, linear expansion, and overdistension by means of %E2 in a subset of the PROVHILO cohort. In 36 patients from 2 participating centers of the PROVHILO trial, we calculated respiratory system elastance (E), resistance (R), and %E2, a surrogate parameter for intratidal overdistension (%E2 > 30%) and R/D (%E2 < 0%). To test the main hypothesis, we compared the incidence of intratidal overdistension (primary end point) and R/D in higher and lower PEEP groups, as measured by %E2. E was increased in the lower compared to higher PEEP group (18.6 [16…22] vs 13.4 [11.0…17.0] cm H2O·L; P < .01). %E2 was reduced in the lower PEEP group compared to higher PEEP (-15.4 [-28.0…6.5] vs 6.2 [-0.8…14.0] %; P < .05). Intratidal R/D was increased in the lower PEEP group (61% vs 22%; P = .037). The incidence of intratidal overdistension did not differ significantly between groups (6%). During mechanical ventilation with protective tidal volumes in patients undergoing open abdominal surgery, lung recruitment followed by PEEP of 12 cm H2O decreased the incidence of intratidal R/D and did not worsen overdistension, when compared

  4. Experimental intra-abdominal hypertension influences airway pressure limits for lung protective mechanical ventilation.

    PubMed

    Cortes-Puentes, Gustavo A; Cortes-Puentes, Luis A; Adams, Alexander B; Anderson, Christopher P; Marini, John J; Dries, David J

    2013-06-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) may complicate monitoring of pulmonary mechanics owing to their impact on the respiratory system. However, recommendations for mechanical ventilation of patients with IAH/ACS and the interpretation of thoracoabdominal interactions remain unclear. Our study aimed to characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Nine deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume (VT) of 10 mL/kg, frequency of 15, inspiratory-expiratory ratio of 1:2, and PEEP of 1 and 10 cm H2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was placed in the peritoneal cavity, and IAP levels of 5, 10, 15, 20, and 25 mm Hg were applied, using a continuous positive airway pressure system. At each IAP level, PBLAD and airway pressure measurements were performed during both PEEP1 and PEEP10. PBLAD increased as experimental IAP rose (y = 0.83x + 0.5; R = 0.98; p < 0.001 at PEEP1). Minimal underestimation of IAP by PBLAD was observed (-2.5 ± 0.8 mm Hg at an IAP of 10-25 mm Hg). Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. Approximately 50% of the PBLAD (in cm H2O) was reflected by changes in PPLAT, regardless of the PEEP level applied. Increasing IAP did not influence hemodynamics at any level of IAP generated. With minimal underestimation, PBLAD measurements closely correlated with experimentally regulated IAP, independent of the PEEP level applied. For each PEEP level applied, a constant proportion (approximately 50%) of measured PBLAD (in cm H2O) was reflected in PPLAT. A higher safety threshold for PPLAT should be considered in the setting of IAH/ACS as the clinician considers changes in VT. A strategy of reducing VT to cap PPLAT at widely recommended values may not be

  5. Protective intraoperative ventilation with higher versus lower levels of positive end-expiratory pressure in obese patients (PROBESE): study protocol for a randomized controlled trial.

    PubMed

    Bluth, T; Teichmann, R; Kiss, T; Bobek, I; Canet, J; Cinnella, G; De Baerdemaeker, L; Gregoretti, C; Hedenstierna, G; Hemmes, S N; Hiesmayr, M; Hollmann, M W; Jaber, S; Laffey, J G; Licker, M J; Markstaller, K; Matot, I; Müller, G; Mills, G H; Mulier, J P; Putensen, C; Rossaint, R; Schmitt, J; Senturk, M; Serpa Neto, A; Severgnini, P; Sprung, J; Vidal Melo, M F; Wrigge, H; Schultz, M J; Pelosi, P; Gama de Abreu, M

    2017-04-28

    Postoperative pulmonary complications (PPCs) increase the morbidity and mortality of surgery in obese patients. High levels of positive end-expiratory pressure (PEEP) with lung recruitment maneuvers may improve intraoperative respiratory function, but they can also compromise hemodynamics, and the effects on PPCs are uncertain. We hypothesized that intraoperative mechanical ventilation using high PEEP with periodic recruitment maneuvers, as compared with low PEEP without recruitment maneuvers, prevents PPCs in obese patients. The PRotective Ventilation with Higher versus Lower PEEP during General Anesthesia for Surgery in OBESE Patients (PROBESE) study is a multicenter, two-arm, international randomized controlled trial. In total, 2013 obese patients with body mass index ≥35 kg/m 2 scheduled for at least 2 h of surgery under general anesthesia and at intermediate to high risk for PPCs will be included. Patients are ventilated intraoperatively with a low tidal volume of 7 ml/kg (predicted body weight) and randomly assigned to PEEP of 12 cmH 2 O with lung recruitment maneuvers (high PEEP) or PEEP of 4 cmH 2 O without recruitment maneuvers (low PEEP). The occurrence of PPCs will be recorded as collapsed composite of single adverse pulmonary events and represents the primary endpoint. To our knowledge, the PROBESE trial is the first multicenter, international randomized controlled trial to compare the effects of two different levels of intraoperative PEEP during protective low tidal volume ventilation on PPCs in obese patients. The results of the PROBESE trial will support anesthesiologists in their decision to choose a certain PEEP level during general anesthesia for surgery in obese patients in an attempt to prevent PPCs. ClinicalTrials.gov identifier: NCT02148692. Registered on 23 May 2014; last updated 7 June 2016.

  6. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation.

    PubMed

    Shojaee, Majid; Sabzghabaei, Anita; Alimohammadi, Hossein; Derakhshanfar, Hojjat; Amini, Afshin; Esmailzadeh, Bahareh

    2017-01-01

    Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH 2 O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male). The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH 2 O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH 2 O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH 2 O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039). The relationship between CVP and 5 cmH 2 O (p = 0.279), and 10 cmH 2 O (p = 0.292) PEEP changes were not dependent on the baseline level of CVP. The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH 2 O increase in PEEP will be associated with about 2.5 cmH 2 O raise in CVP. When applying a 5 cmH 2 O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH 2 O (2.5 vs. 1.6). It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  7. Titration of Ideal Positive End-expiratory Pressure in Acute Respiratory Distress Syndrome: Comparison between Lower Inflection Point and Esophageal Pressure Method Using Volumetric Capnography.

    PubMed

    Baikunje, Nandakishore; Sehgal, Inderpaul Singh; Dhooria, Sahajal; Prasad, Kuruswamy Thurai; Agarwal, Ritesh

    2017-05-01

    The tenets of mechanical ventilation in acute respiratory distress syndrome (ARDS) include the utilization of low tidal volume and optimal application of positive end-expiratory pressure (PEEP). Optimal PEEP in ARDS is characterized by reduction in alveolar dead space along with improvement in the lung compliance and resultant betterment in oxygenation. There are various methods of setting PEEP in ARDS. Herein, we report a patient of ARDS, wherein we employed measurement of dead space using volumetric capnography to compare two different PEEP strategies, namely, the lower inflection point and transpulmonary pressure monitoring.

  8. Effects of positive end expiratory pressure administration during non-invasive ventilation in patients affected by amyotrophic lateral sclerosis: A randomized crossover study.

    PubMed

    Crescimanno, Grazia; Greco, Francesca; Arrisicato, Salvo; Morana, Noemi; Marrone, Oreste

    2016-10-01

    No studies have evaluated the impact of different settings of non-invasive ventilation (NIV) in patients affected by amyotrophic lateral sclerosis (ALS). We explored consequences of positive end-expiratory pressure (PEEP) application on effectiveness of ventilation, sleep architecture and heart rate variability (HRV) in patients with ALS naïve to ventilatory treatment. In two consecutive nights, 25 patients received in random order 0 or 4 cm H2 0 of PEEP during nocturnal NIV administration (Idea Ultra ResMed) with the same level of total positive inspiratory pressure. Polysomnographies were performed to evaluate sleep and NIV quality, as well as HRV. HRV was analyzed on 4-h periods and on 5-min segments of stable NREM sleep. We did not observe differences in gas exchanges during NIV with and without PEEP. Conversely, during PEEP application increases in leaks (41.4 ± 29.3% vs 31.0 ± 25.7%, P = 0.0007) and in autotriggerings (4.2 (IQR 1.3-10.0) vs 0.9 (IQR 0.0-3.0) events/h, P < 0.001, PEEP vs no PEEP, respectively) occurred. Besides, N3 sleep stage duration decreased (2.5% (IQR 0.0-18.0) vs 0.0% (IQR0.0-12.1), P = 0.001) and arousal/awakening index increased (16.9 ± 7.4 vs 13.4 ± 5.0 events/h, P = 0.01). Data on HRV were available in 15 patients. A higher low/high frequency ratio, either in the 4-h (3.8 ± 2.6 vs 2.9 ± 1.7, P = 0.04, PEEP vs no PEEP, respectively) or in the 5-min segments (2.6 ± 1.8 vs 1.45 ± 0.9 P = 0.01) was found during PEEP administration. In ALS patients, PEEP application during NIV was associated with worse NIV and sleep quality and with higher sympathetic activity. © 2016 Asian Pacific Society of Respirology.

  9. Positive End-Expiratory Pressure and Variable Ventilation in Lung-Healthy Rats under General Anesthesia

    PubMed Central

    Camilo, Luciana M.; Ávila, Mariana B.; Cruz, Luis Felipe S.; Ribeiro, Gabriel C. M.; Spieth, Peter M.; Reske, Andreas A.; Amato, Marcelo; Giannella-Neto, Antonio; Zin, Walter A.; Carvalho, Alysson R.

    2014-01-01

    Objectives Variable ventilation (VV) seems to improve respiratory function in acute lung injury and may be combined with positive end-expiratory pressure (PEEP) in order to protect the lungs even in healthy subjects. We hypothesized that VV in combination with moderate levels of PEEP reduce the deterioration of pulmonary function related to general anesthesia. Hence, we aimed at evaluating the alveolar stability and lung protection of the combination of VV at different PEEP levels. Design Randomized experimental study. Setting Animal research facility. Subjects Forty-nine male Wistar rats (200–270 g). Interventions Animals were ventilated during 2 hours with protective low tidal volume (VT) in volume control ventilation (VCV) or VV and PEEP adjusted at the level of minimum respiratory system elastance (Ers), obtained during a decremental PEEP trial subsequent to a recruitment maneuver, and 2 cmH2O above or below of this level. Measurements and Main Results Ers, gas exchange and hemodynamic variables were measured. Cytokines were determined in lung homogenate and plasma samples and left lung was used for histologic analysis and diffuse alveolar damage scoring. A progressive time-dependent increase in Ers was observed independent on ventilatory mode or PEEP level. Despite of that, the rate of increase of Ers and lung tissue IL-1 beta concentration were significantly lower in VV than in VCV at the level of the PEEP of minimum Ers. A significant increase in lung tissue cytokines (IL-6, IL-1 beta, CINC-1 and TNF-alpha) as well as a ventral to dorsal and cranial to caudal reduction in aeration was observed in all ventilated rats with no significant differences among groups. Conclusions VV combined with PEEP adjusted at the level of the PEEP of minimal Ers seemed to better prevent anesthesia-induced atelectasis and might improve lung protection throughout general anesthesia. PMID:25383882

  10. Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy.

    PubMed

    Sen, Oznur; Erdogan Doventas, Yasemin

    General anesthesia causes reduction of functional residual capacity. And this decrease can lead to atelectasis and intrapulmonary shunting in the lung. In this study we want to evaluate the effects of 5 and 10cmH 2 O PEEP levels on gas exchange, hemodynamic, respiratory mechanics and systemic stress response in laparoscopic cholecystectomy. American Society of Anesthesiologist I-II physical status 43 patients scheduled for laparoscopic cholecystectomy were randomly selected to receive external PEEP of 5cmH 2 O (PEEP 5 group) or 10cmH 2 O PEEP (PEEP 10 group) during pneumoperitoneum. Basal hemodynamic parameters were recorded, and arterial blood gases (ABG) and blood sampling were done for cortisol, insulin and glucose level estimations to assess the systemic stress response before induction of anesthesia. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, and glucose levels were repeated. Lastly hemodynamic parameters were recorded; ABG analysis and sampling for stress response levels were taken after 60minutes from extubation. There were no statistical differences between the two groups about hemodynamic and respiratory parameters except mean airway pressure (P mean ). P mean , compliance and PaO 2 ; pH values were higher in 'PEEP 10 group'. Also, PaCO 2 values were lower in 'PEEP 10 group'. No differences were observed between insulin and lactic acid levels in the two groups. But postoperative cortisol level was significantly lower in 'PEEP 10 group'. Ventilation with 10cmH 2 O PEEP increases compliance and oxygenation, does not cause hemodynamic and respiratory complications and reduces the postoperative stress response. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  11. [Effects of different levels of end-expiratory pressure on hemodynamic, respiratory mechanics and systemic stress response during laparoscopic cholecystectomy].

    PubMed

    Sen, Oznur; Erdogan Doventas, Yasemin

    General anesthesia causes reduction of functional residual capacity. And this decrease can lead to atelectasis and intrapulmonary shunting in the lung. In this study we want to evaluate the effects of 5 and 10cmH 2 O PEEP levels on gas exchange, hemodynamic, respiratory mechanics and systemic stress response in laparoscopic cholecystectomy. American Society of Anesthesiologist I-II physical status 43 patients scheduled for laparoscopic cholecystectomy were randomly selected to receive external PEEP of 5cmH 2 O (PEEP 5 group) or 10cmH 2 O PEEP (PEEP 10 group) during pneumoperitoneum. Basal hemodynamic parameters were recorded, and arterial blood gases (ABG) and blood sampling were done for cortisol, insulin and glucose level estimations to assess the systemic stress response before induction of anesthesia. Thirty minutes after the pneumoperitoneum, the respiratory and hemodynamic parameters were recorded again and ABG and sampling for cortisol, insulin, and glucose levels were repeated. Lastly hemodynamic parameters were recorded; ABG analysis and sampling for stress response levels were taken after 60minutes from extubation. There were no statistical differences between the two groups about hemodynamic and respiratory parameters except mean airway pressure (P mean ). P mean , compliance and PaO 2 ; pH values were higher in 'PEEP 10 group'. Also, PaCO 2 values were lower in 'PEEP 10 group'. No differences were observed between insulin and lactic acid levels in the two groups. But postoperative cortisol level was significantly lower in 'PEEP 10 group'. Ventilation with 10cmH 2 O PEEP increases compliance and oxygenation, does not cause hemodynamic and respiratory complications and reduces the postoperative stress response. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  12. Continuous Negative Abdominal Pressure Reduces Ventilator-induced Lung Injury in a Porcine Model.

    PubMed

    Yoshida, Takeshi; Engelberts, Doreen; Otulakowski, Gail; Katira, Bhushan; Post, Martin; Ferguson, Niall D; Brochard, Laurent; Amato, Marcelo B P; Kavanagh, Brian P

    2018-04-27

    In supine patients with acute respiratory distress syndrome, the lung typically partitions into regions of dorsal atelectasis and ventral aeration ("baby lung"). Positive airway pressure is often used to recruit atelectasis, but often overinflates ventral (already aerated) regions. A novel approach to selective recruitment of dorsal atelectasis is by "continuous negative abdominal pressure." A randomized laboratory study was performed in anesthetized pigs. Lung injury was induced by surfactant lavage followed by 1 h of injurious mechanical ventilation. Randomization (five pigs in each group) was to positive end-expiratory pressure (PEEP) alone or PEEP with continuous negative abdominal pressure (-5 cm H2O via a plexiglass chamber enclosing hindlimbs, pelvis, and abdomen), followed by 4 h of injurious ventilation (high tidal volume, 20 ml/kg; low expiratory transpulmonary pressure, -3 cm H2O). The level of PEEP at the start was ≈7 (vs. ≈3) cm H2O in the PEEP (vs. PEEP plus continuous negative abdominal pressure) groups. Esophageal pressure, hemodynamics, and electrical impedance tomography were recorded, and injury determined by lung wet/dry weight ratio and interleukin-6 expression. All animals survived, but cardiac output was decreased in the PEEP group. Addition of continuous negative abdominal pressure to PEEP resulted in greater oxygenation (PaO2/fractional inspired oxygen 316 ± 134 vs. 80 ± 24 mmHg at 4 h, P = 0.005), compliance (14.2 ± 3.0 vs. 10.3 ± 2.2 ml/cm H2O, P = 0.049), and homogeneity of ventilation, with less pulmonary edema (≈10% less) and interleukin-6 expression (≈30% less). Continuous negative abdominal pressure added to PEEP reduces ventilator-induced lung injury in a pig model compared with PEEP alone, despite targeting identical expiratory transpulmonary pressure.

  13. Effect of betamethasone, surfactant, and positive end-expiratory pressures on lung aeration at birth in preterm rabbits.

    PubMed

    Crawshaw, Jessica R; Hooper, Stuart B; Te Pas, Arjan B; Allison, Beth A; Wallace, Megan J; Kerr, Lauren T; Lewis, Robert A; Morley, Colin J; Leong, Andrew F; Kitchen, Marcus J

    2016-09-01

    Antenatal glucocorticoids, exogenous surfactant, and positive end-expiratory pressure (PEEP) ventilation are commonly provided to preterm infants to enhance respiratory function after birth. It is unclear how these treatments interact to improve the transition to air-breathing at birth. We investigated the relative contribution of antenatal betamethasone, prophylactic surfactant, and PEEP (3 cmH 2 O) on functional residual capacity (FRC) and dynamic lung compliance (C DL ) in preterm (28 day GA) rabbit kittens at birth. Kittens were delivered by cesarean section and mechanically ventilated. FRC was calculated from X-ray images, and C DL was measured using plethysmography. Without betamethasone, PEEP increased FRC recruitment and C DL Surfactant did not further increase FRC, but significantly increased C DL Betamethasone abolished the benefit of PEEP on FRC, but surfactant counteracted this effect of betamethasone. These findings indicate that low PEEP levels are insufficient to establish FRC at birth following betamethasone treatment. However, surfactant reversed the effect of betamethasone and when combined, these two treatments enhanced FRC recruitment irrespective of PEEP level. Copyright © 2016 the American Physiological Society.

  14. The Effect of Positive End-Expiratory Pressure on Intracranial Pressure and Cerebral Hemodynamics.

    PubMed

    Boone, Myles D; Jinadasa, Sayuri P; Mueller, Ariel; Shaefi, Shahzad; Kasper, Ekkehard M; Hanafy, Khalid A; O'Gara, Brian P; Talmor, Daniel S

    2017-04-01

    Lung protective ventilation has not been evaluated in patients with brain injury. It is unclear whether applying positive end-expiratory pressure (PEEP) adversely affects intracranial pressure (ICP) and cerebral perfusion pressure (CPP). We aimed to evaluate the effect of PEEP on ICP and CPP in a large population of patients with acute brain injury and varying categories of acute lung injury, defined by PaO 2 /FiO 2 . Retrospective data were collected from 341 patients with severe acute brain injury admitted to the ICU between 2008 and 2015. These patients experienced a total of 28,644 paired PEEP and ICP observations. Demographic, hemodynamic, physiologic, and ventilator data at the time of the paired PEEP and ICP observations were recorded. In the adjusted analysis, a statistically significant relationship between PEEP and ICP and PEEP and CPP was found only among observations occurring during periods of severe lung injury. For every centimeter H 2 O increase in PEEP, there was a 0.31 mmHg increase in ICP (p = 0.04; 95 % CI [0.07, 0.54]) and a 0.85 mmHg decrease in CPP (p = 0.02; 95 % CI [-1.48, -0.22]). Our results suggest that PEEP can be applied safely in patients with acute brain injury as it does not have a clinically significant effect on ICP or CPP. Further prospective studies are required to assess the safety of applying a lung protective ventilation strategy in brain-injured patients with lung injury.

  15. Combined Effects of Ventilation Mode and Positive End-Expiratory Pressure on Mechanics, Gas Exchange and the Epithelium in Mice with Acute Lung Injury

    PubMed Central

    Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla

    2013-01-01

    The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543

  16. Effects of Mechanical Ventilation on Heart Geometry and Mitral Valve Leaflet Coaptation During Percutaneous Edge-to-Edge Mitral Valve Repair.

    PubMed

    Patzelt, Johannes; Zhang, Yingying; Seizer, Peter; Magunia, Harry; Henning, Andreas; Riemlova, Veronika; Patzelt, Tara A E; Hansen, Marc; Haap, Michael; Riessen, Reimer; Lausberg, Henning; Walker, Tobias; Reutershan, Joerg; Schlensak, Christian; Grasshoff, Christian; Simon, Dan I; Rosenberger, Peter; Schreieck, Juergen; Gawaz, Meinrad; Langer, Harald F

    2016-01-25

    This study sought to evaluate a ventilation maneuver to facilitate percutaneous edge-to-edge mitral valve repair (PMVR) and its effects on heart geometry. In patients with challenging anatomy, the application of PMVR is limited, potentially resulting in insufficient reduction of mitral regurgitation (MR) or clip detachment. Under general anesthesia, however, ventilation maneuvers can be used to facilitate PMVR. A total of 50 consecutive patients undergoing PMVR were included. During mechanical ventilation, different levels of positive end-expiratory pressure (PEEP) were applied, and parameters of heart geometry were assessed using transesophageal echocardiography. We found that increased PEEP results in elevated central venous pressure. Specifically, central venous pressure increased from 14.0 ± 6.5 mm Hg (PEEP 3 mm Hg) to 19.3 ± 5.9 mm Hg (PEEP 20 mm Hg; p < 0.001). As a consequence, the reduced pre-load resulted in reduction of the left ventricular end-systolic diameter from 43.8 ± 10.7 mm (PEEP 3 mm Hg) to 39.9 ± 11.0 mm (PEEP 20 mm Hg; p < 0.001), mitral valve annulus anterior-posterior diameter from 32.4 ± 4.3 mm (PEEP 3 mm Hg) to 30.5 ± 4.4 mm (PEEP 20 mm Hg; p < 0.001), and the medio-lateral diameter from 35.4 ± 4.2 mm to 34.1 ± 3.9 mm (p = 0.002). In parallel, we observed a significant increase in leaflet coaptation length from 3.0 ± 0.8 mm (PEEP 3 mm Hg) to 5.4 ± 1.1 mm (PEEP 20 mm Hg; p < 0.001). The increase in coaptation length was more pronounced in MR with functional or mixed genesis. Importantly, a coaptation length >4.9 mm at PEEP of 10 mm Hg resulted in a significant reduction of PMVR procedure time (152 ± 49 min to 116 ± 26 min; p = 0.05). In this study, we describe a novel ventilation maneuver improving mitral valve coaptation length during the PMVR procedure, which facilitates clip positioning. Our observations could help to improve PMVR therapy and could make nonsurgical candidates accessible to PMVR therapy, particularly in

  17. Effects of inhaled fenoterol and positive end-expiratory pressure on the respiratory mechanics of patients with chronic obstructive pulmonary disease.

    PubMed

    Guérin, Claude; Durand, Pierre-Guy; Pereira, Cécile; Richard, Jean-Christophe; Poupelin, Jean-Charles; Lemasson, Stéphane; Badet, Michel; Philit, François; Vecellio, Laurent; Chantrel, Gilles

    2005-09-01

    During acute ventilatory failure in patients with chronic obstructive pulmonary disease (COPD), applying external positive end-expiratory pressure (PEEPe) will reopen small airways and, thus, may enhance peripheral deposition as well as the physiological effects of inhaled beta-2 agonists. To investigate the efficacy of inhaled fenoterol applied by zero end-expiratory pressure (ZEEPe) or PEEPe. Ten patients with COPD who were intubated and mechanically ventilated received fenoterol (10 mg/4 mL) via the ventilator using a jet nebulizer for 30 min on ZEEPe and PEEPe set at 80% of the total PEEP in a random order. The total resistance of the respiratory system (rapid airway occlusion technique), change in end-expiratory lung volume and expiratory flow limitation were assessed before and 5 min, 15 min, 30 min, 60 min and 240 min after fenoterol inhalation. Before inhalation and 60 min after inhalation, the total PEEP, the change in end-expiratory lung volume and the total resistance of the respiratory system were 8+/-3 cmH2O and 6+/-3 cmH2O, 0.61+/-0.34 L and 0.43+/-0.32 L, and 26+/-7 cmH2O/L/s and 23+/-6 cmH2O/L/s, respectively, with ZEEPe, and 9+/-3 cmH2O and 8+/-3 cmH2O (P<0.05 versus ZEEPe), 0.62+/-0.34 L and 0.62+/-0.37 L (P<0.05 versus ZEEPe), and 26+/-9 H2O/L/s and 25+/-9 H2O/L/s, respectively, with PEEPe. Three patients became not flow-limited under the combination of PEEPe and fenoterol. In patients with COPD, fenoterol combined with PEEPe has opposing effects on respiratory mechanics. First, it does not significantly reduce lung hyperinflation or inspiratory resistances. Second, it allows expiratory flow limitation reversal in some patients. These findings result from the net effect on end-expiratory lung volume of each intervention. This implies that if fenoterol is used in combination with PEEPe, the level of PEEPe should be reassessed during the time course of the drug to prevent any further lung hyperinflation.

  18. Ventilation with positive end-expiratory pressure reduces extravascular lung water and increases lymphatic flow in hydrostatic pulmonary edema.

    PubMed

    Fernández Mondéjar, E; Vazquez Mata, G; Cárdenas, A; Mansilla, A; Cantalejo, F; Rivera, R

    1996-09-01

    To analyze the effect of different levels of positive end-expiratory pressure (PEEP) on extravascular lung water and on lymphatic drainage through the thoracic duct during hydrostatic pulmonary edema. Randomized, controlled, experimental study. Research laboratory of a tertiary care hospital. Eighteen beagle dogs weighing between 10 and 19 kg. Dogs were anesthetized and cannulated via a thoracic duct. Hydrostatic pulmonary edema was provoked by inflating the balloon of a Foley catheter in the left atrium. Different amounts of PEEP were applied. Extravascular lung water was determined by the double indicator dilution method (indocyanine green in glucoside solution at 0 degree C), and lymphatic drainage was measured every 30 mins. After a baseline measurement, the left atrial pressure was increased to 24 to 26 mm Hg, and measurements were recorded after 30, 60, 90, and 120 mins. The animals were divided into three groups. Group I (n = 6): PEEP of 20 cm H2O was instituted at 120 mins, and the other determinations were made without PEEP; group II (n = 7): PEEP of 10 cm H2O was instituted at 60 and 90 mins; group III (n = 5): PEEP of 20 cm H2O was instituted at 60 and 90 mins. Extravascular lung water increased after the increase of left atrial pressure in all three groups. After 90 mins, the extravascular lung water was significantly greater (p < .01) in group I (no PEEP application) at 21.2 +/- 5.1 mL/kg than in groups II and III (with 10 and 20 cm H2O of PEEP) at 12.8 +/- 2.01 and 14.8 +/- 4.8 mL/kg, respectively. Lymphatic drainage tended to increase over time in all three groups. Ninety minutes after the left atrial pressure increase, lymphatic drainage was significantly greater (p < .05) in group II, at 6.06 +/- 2.53 mL/kg/30 mins, than in group I, at 2.83 +/- 0.76 mL/kg/30 mins. a) The application of PEEP levels of between 10 and 20 cm H2O limits the increase of extravascular lung water in cases of hydrostatic pulmonary edema; and b) the application of 10 cm H2O

  19. Application of dead space fraction to titrate optimal positive end-expiratory pressure in an ARDS swine model.

    PubMed

    Bian, Weishuai; Chen, Wei; Chao, Yangong; Wang, Lan; Li, Liming; Guan, Jian; Zang, Xuefeng; Zhen, Jie; Sheng, Bo; Zhu, Xi

    2017-04-01

    This study aimed to apply the dead space fraction [ratio of dead space to tidal volume (VD/VT)] to titrate the optimal positive end-expiratory pressure (PEEP) in a swine model of acute respiratory distress syndrome (ARDS). Twelve swine models of ARDS were constructed. A lung recruitment maneuver was then conducted and the PEEP was set at 20 cm H 2 O. The PEEP was reduced by 2 cm H 2 O every 10 min until 0 cm H 2 O was reached, and VD/VT was measured after each decrement step. VD/VT was measured using single-breath analysis of CO 2 , and calculated from arterial CO 2 partial pressure (PaCO 2 ) and mixed expired CO 2 (PeCO 2 ) using the following formula: VD/VT = (PaCO 2 - PeCO 2 )/PaCO 2 . The optimal PEEP was identified by the lowest VD/VT method. Respiration and hemodynamic parameters were recorded during the periods of pre-injury and injury, and at 4 and 2 cm H 2 O below and above the optimal PEEP (Po). The optimal PEEP in this study was found to be 13.25±1.36 cm H 2 O. During the Po period, VD/VT decreased to a lower value (0.44±0.08) compared with that during the injury period (0.68±0.10) (P<0.05), while the intrapulmonary shunt fraction reached its lowest value. In addition, a significant change of dynamic tidal respiratory compliance and oxygenation index was induced by PEEP titration. These results indicate that minimal VD/VT can be used for PEEP titration in ARDS.

  20. Clinical review: Positive end-expiratory pressure and cardiac output

    PubMed Central

    Luecke, Thomas; Pelosi, Paolo

    2005-01-01

    In patients with acute lung injury, high levels of positive end-expiratory pressure (PEEP) may be necessary to maintain or restore oxygenation, despite the fact that 'aggressive' mechanical ventilation can markedly affect cardiac function in a complex and often unpredictable fashion. As heart rate usually does not change with PEEP, the entire fall in cardiac output is a consequence of a reduction in left ventricular stroke volume (SV). PEEP-induced changes in cardiac output are analyzed, therefore, in terms of changes in SV and its determinants (preload, afterload, contractility and ventricular compliance). Mechanical ventilation with PEEP, like any other active or passive ventilatory maneuver, primarily affects cardiac function by changing lung volume and intrathoracic pressure. In order to describe the direct cardiocirculatory consequences of respiratory failure necessitating mechanical ventilation and PEEP, this review will focus on the effects of changes in lung volume, factors controlling venous return, the diastolic interactions between the ventricles and the effects of intrathoracic pressure on cardiac function, specifically left ventricular function. Finally, the hemodynamic consequences of PEEP in patients with heart failure, chronic obstructive pulmonary disease and acute respiratory distress syndrome are discussed. PMID:16356246

  1. Effects of positive end-expiratory pressure and 30% inspired oxygen on pulmonary mechanics and atelectasis in cats undergoing non-bronchoscopic bronchoalveolar lavage.

    PubMed

    Bernhard, Christa; Masseau, Isabelle; Dodam, John; Outi, Hilton; Krumme, Stacy; Bishop, Kaitlin; Graham, Amber; Reinero, Carol

    2017-06-01

    Objectives The objective of this study was to determine if modification of inspired oxygen concentration or positive end-expiratory pressure (PEEP) would alter bronchoalveolar lavage (BAL)-induced changes in pulmonary mechanics or atelectasis, as measured using ventilator-acquired pulmonary mechanics and thoracic CT. Methods Six experimentally asthmatic cats underwent anesthesia and non-bronchoscopic BAL, each under four randomized treatment conditions: 100% oxygen, zero PEEP; 30% oxygen, zero PEEP; 100% oxygen, PEEP 2 cmH 2 O; and 30% oxygen, PEEP 2 cmH 2 O. Pulse oximetry was used to estimate oxygen saturation (SpO 2 ). Ventilator-acquired pulmonary mechanics and thoracic CT scans were collected prior to BAL and at 1, 5 and 15 mins post-BAL. Results While receiving 100% oxygen, no cat had SpO 2 <91%. Some cats receiving 30% oxygen had decreased saturation immediately post-BAL (mean ± SD 70.8 ± 31%), but 6/8 of these had SpO 2 >90% by 1 min later. There was a significant increase in airway resistance and a decrease in lung compliance following BAL, but there was no significant difference between treatment groups. Cats receiving no PEEP and 30% oxygen conserved better aeration of the lung parenchyma in BAL-sampled areas than those receiving no PEEP and 100% oxygen. Conclusions and relevance Alterations in pulmonary mechanics or atelectasis may not be reflected by SpO 2 following BAL. The use of 30% inspired oxygen concentration failed to show any significant improvement in pulmonary mechanics but did diminish atelectasis. In some cats, it was also associated with desaturation of hemoglobin. The use of PEEP in this study did not show any effect on our outcome parameters. Further studies using higher PEEP (5-10 cmH 2 O) and intermediate inspired oxygen concentration (40-60%) are warranted to determine if they would confer clinical benefit in cats undergoing diagnostic BAL.

  2. Open lung approach versus standard protective strategies: Effects on driving pressure and ventilatory efficiency during anesthesia - A pilot, randomized controlled trial.

    PubMed

    Ferrando, Carlos; Suarez-Sipmann, Fernando; Tusman, Gerardo; León, Irene; Romero, Esther; Gracia, Estefania; Mugarra, Ana; Arocas, Blanca; Pozo, Natividad; Soro, Marina; Belda, Francisco J

    2017-01-01

    Low tidal volume (VT) during anesthesia minimizes lung injury but may be associated to a decrease in functional lung volume impairing lung mechanics and efficiency. Lung recruitment (RM) can restore lung volume but this may critically depend on the post-RM selected PEEP. This study was a randomized, two parallel arm, open study whose primary outcome was to compare the effects on driving pressure of adding a RM to low-VT ventilation, with or without an individualized post-RM PEEP in patients without known previous lung disease during anesthesia. Consecutive patients scheduled for major abdominal surgery were submitted to low-VT ventilation (6 ml·kg-1) and standard PEEP of 5 cmH2O (pre-RM, n = 36). After 30 min estabilization all patients received a RM and were randomly allocated to either continue with the same PEEP (RM-5 group, n = 18) or to an individualized open-lung PEEP (OL-PEEP) (Open Lung Approach, OLA group, n = 18) defined as the level resulting in maximal Cdyn during a decremental PEEP trial. We compared the effects on driving pressure and lung efficiency measured by volumetric capnography. OL-PEEP was found at 8±2 cmH2O. 36 patients were included in the final analysis. When compared with pre-RM, OLA resulted in a 22% increase in compliance and a 28% decrease in driving pressure when compared to pre-RM. These parameters did not improve in the RM-5. The trend of the DP was significantly different between the OLA and RM-5 groups (p = 0.002). VDalv/VTalv was significantly lower in the OLA group after the RM (p = 0.035). Lung recruitment applied during low-VT ventilation improves driving pressure and lung efficiency only when applied as an open-lung strategy with an individualized PEEP in patients without lung diseases undergoing major abdominal surgery. ClinicalTrials.gov NCT02798133.

  3. Effects of positive end-expiratory pressure on intracranial pressure in mechanically ventilated dogs under hyperbaric oxygenation.

    PubMed

    Sun, Qing; Wu, Di; Yu, Tao; Yang, Ying; Wei, Li; Lv, Fuxiang; Gao, Guangkai

    2014-01-01

    Mechanical ventilation with positive end-expiratory pressure (PEEP) has been advocated as an essential life support for critical patients. However, its side effect, which is demonstrated by an elevation of intracranial pressure (ICP) under normobaric (NBO2) conditions, is potentially detrimental to patients. Hyperbaric oxygen (HBO2) therapy, on the other hand, is frequently applied for the same group of patients, and its efficacy is shown by maintaining a higher PaO2 and a reduced ICP. Our study investigated the effect of HBO2 and NBO2 on ICP with or without PEEP ventilation on healthy dogs by comparing cerebrospinal fluid pressure (CSFP) and concluded that the elevation of PEEP resulted in a significant increase of ICP (CSFP) under both conditions (p < 0.05). HBO2 leads to a lower ICP increase compared to the NBO2 group. Under the same level of PEEP, the joint use of PEEP and HBO2 is safe and highly practical in clinical medicine.

  4. Prediction of high airway pressure using a non-linear autoregressive model of pulmonary mechanics.

    PubMed

    Langdon, Ruby; Docherty, Paul D; Schranz, Christoph; Chase, J Geoffrey

    2017-11-02

    For mechanically ventilated patients with acute respiratory distress syndrome (ARDS), suboptimal PEEP levels can cause ventilator induced lung injury (VILI). In particular, high PEEP and high peak inspiratory pressures (PIP) can cause over distension of alveoli that is associated with VILI. However, PEEP must also be sufficient to maintain recruitment in ARDS lungs. A lung model that accurately and precisely predicts the outcome of an increase in PEEP may allow dangerous high PIP to be avoided, and reduce the incidence of VILI. Sixteen pressure-flow data sets were collected from nine mechanically ventilated ARDs patients that underwent one or more recruitment manoeuvres. A nonlinear autoregressive (NARX) model was identified on one or more adjacent PEEP steps, and extrapolated to predict PIP at 2, 4, and 6 cmH 2 O PEEP horizons. The analysis considered whether the predicted and measured PIP exceeded a threshold of 40 cmH 2 O. A direct comparison of the method was made using the first order model of pulmonary mechanics (FOM(I)). Additionally, a further, more clinically appropriate method for the FOM was tested, in which the FOM was trained on a single PEEP prior to prediction (FOM(II)). The NARX model exhibited very high sensitivity (> 0.96) in all cases, and a high specificity (> 0.88). While both FOM methods had a high specificity (> 0.96), the sensitivity was much lower, with a mean of 0.68 for FOM(I), and 0.82 for FOM(II). Clinically, false negatives are more harmful than false positives, as a high PIP may result in distension and VILI. Thus, the NARX model may be more effective than the FOM in allowing clinicians to reduce the risk of applying a PEEP that results in dangerously high airway pressures.

  5. [A comparison of leak compensation in six acute care ventilators during non-invasive ventilation].

    PubMed

    Hu, X S; Wang, Y; Wang, Z T; Yan, P; Zhang, X G; Zhao, S F; Xie, F; Gu, H J; Xie, L X

    2017-02-12

    Objective: To compare the ability of leak compensation in 6 medical ventilators during non-invasive ventilation. Methods: Six medical ventilators were selected, including 3 non-invasive ventilators (V60, Flexo and Stellar150), and 3 invasive ventilators(Avea, Servo I and BellaVist). Using a lung simulator, the ability of leak compensation was evaluated during triggering and cycling in 2 respiratory mechanics conditions (high airway resistance condition and high elastance resistance condition), and each condition was performed under 2 PEEP levels (4, and 8 cmH(2)O, 1 mmHg=0.098 kPa) at 4 air leak level conditions (L0: 2-3 L/min, L1: 8-10 L/min, L2: 22-27 L/min, L3: 35-40 L/min). Results: In the high elastance resistance condition (L2, L3)with different leak levels, the number of auto-triggering and miss-triggering of the non-invasive ventilator Flexo was significantly less than those of the others (L2: 1, 1; L3: 1.67, 1.33, P <0.01), and had better synchronization (L2: 2.33, 2.33; L3: 3.33, 3.33, P <0.01). In the high airway resistance condition with PEEP 4 cmH(2)O, V60 had less number of auto-triggering than other ventilators ( P <0.01), while in the high airway resistance condition with PEEP 8 cmH(2)O, Stellar150 had less number of miss-triggering than other ventilators (1, 0.67, 0, P <0.01). Flexo had a shorter trigger delay time than other ventilators in both high airway resistance and high elastance resistance conditions with L0 and L1 leak levels and PEEP levels [ARDS, PEEP=4: (109.8±1.8) ms, (112.0±0.6) ms; ARDS, PEEP=8: (103.1±0.7) ms, (109.7±0.7) ms; COPD, PEEP=4: (207.3±1.1) ms, (220.8±1.1) ms; COPD, PEEP=8: (195.6±6.7) ms, (200.0±1.2) ms , P <0.01]. Stellar150 had the shortest trigger delay time in high airway resistance condition with PEEP 4 cmH(2)O and high leak level L3[(262.8±0.8) ms , P <0.01]. V60 had a good performance on trigger delay time in high elastance resistance condition with PEEP 4 and 8 cmH(2)O, and also was most stable in

  6. Sustained Aeration of Infant Lungs (SAIL) trial: study protocol for a randomized controlled trial.

    PubMed

    Foglia, Elizabeth E; Owen, Louise S; Thio, Marta; Ratcliffe, Sarah J; Lista, Gianluca; Te Pas, Arjan; Hummler, Helmut; Nadkarni, Vinay; Ades, Anne; Posencheg, Michael; Keszler, Martin; Davis, Peter; Kirpalani, Haresh

    2015-03-15

    Extremely preterm infants require assistance recruiting the lung to establish a functional residual capacity after birth. Sustained inflation (SI) combined with positive end expiratory pressure (PEEP) may be a superior method of aerating the lung compared with intermittent positive pressure ventilation (IPPV) with PEEP in extremely preterm infants. The Sustained Aeration of Infant Lungs (SAIL) trial was designed to study this question. This multisite prospective randomized controlled unblinded trial will recruit 600 infants of 23 to 26 weeks gestational age who require respiratory support at birth. Infants in both arms will be treated with PEEP 5 to 7 cm H2O throughout the resuscitation. The study intervention consists of performing an initial SI (20 cm H20 for 15 seconds) followed by a second SI (25 cm H2O for 15 seconds), and then PEEP with or without IPPV, as needed. The control group will be treated with initial IPPV with PEEP. The primary outcome is the combined endpoint of bronchopulmonary dysplasia or death at 36 weeks post-menstrual age. www.clinicaltrials.gov , Trial identifier NCT02139800 , Registered 13 May 2014.

  7. Effects on lung stress of position and different doses of perfluorocarbon in a model of ARDS.

    PubMed

    López-Aguilar, Josefina; Lucangelo, Umberto; Albaiceta, Guillermo M; Nahum, Avi; Murias, Gastón; Cañizares, Rosario; Oliva, Joan Carles; Romero, Pablo V; Blanch, Lluís

    2015-05-01

    We determined whether the combination of low dose partial liquid ventilation (PLV) with perfluorocarbons (PFC) and prone positioning improved lung function while inducing minimal stress. Eighteen pigs with acute lung injury were assigned to conventional mechanical ventilation (CMV) or PLV (5 or 10 ml/kg of PFC). Positive end-expiratory pressure (PEEP) trials in supine and prone positions were performed. Data were analyzed by a multivariate polynomial regression model. The interplay between PLV and position depended on the PEEP level. In supine PLV dampened the stress induced by increased PEEP during the trial. The PFC dose of 5 ml/kg was more effective than the dose 10 ml/kg. This effect was not observed in prone. Oxygenation was significantly higher in prone than in supine position mainly at lower levels of PEEP. In conclusion, MV settings should take both gas exchange and stress/strain into account. When protective CMV fails, rescue strategies combining prone positioning and PLV with optimal PEEP should improve gas exchange with minimal stress. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis.

    PubMed

    Serpa Neto, Ary; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Binnekade, Jan M; Canet, Jaume; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Hedenstierna, Göran; Hollmann, Markus W; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Putensen, Christian; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Schmid, Werner; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2015-07-01

    Recent studies show that intraoperative mechanical ventilation using low tidal volumes (VT) can prevent postoperative pulmonary complications (PPCs). The aim of this individual patient data meta-analysis is to evaluate the individual associations between VT size and positive end-expiratory pressure (PEEP) level and occurrence of PPC. Randomized controlled trials comparing protective ventilation (low VT with or without high levels of PEEP) and conventional ventilation (high VT with low PEEP) in patients undergoing general surgery. The primary outcome was development of PPC. Predefined prognostic factors were tested using multivariate logistic regression. Fifteen randomized controlled trials were included (2,127 patients). There were 97 cases of PPC in 1,118 patients (8.7%) assigned to protective ventilation and 148 cases in 1,009 patients (14.7%) assigned to conventional ventilation (adjusted relative risk, 0.64; 95% CI, 0.46 to 0.88; P < 0.01). There were 85 cases of PPC in 957 patients (8.9%) assigned to ventilation with low VT and high PEEP levels and 63 cases in 525 patients (12%) assigned to ventilation with low VT and low PEEP levels (adjusted relative risk, 0.93; 95% CI, 0.64 to 1.37; P = 0.72). A dose-response relationship was found between the appearance of PPC and VT size (R2 = 0.39) but not between the appearance of PPC and PEEP level (R2 = 0.08). These data support the beneficial effects of ventilation with use of low VT in patients undergoing surgery. Further trials are necessary to define the role of intraoperative higher PEEP to prevent PPC during nonopen abdominal surgery.

  9. Pulmonary lesion induced by low and high positive end-expiratory pressure levels during protective ventilation in experimental acute lung injury.

    PubMed

    Pássaro, Caroline P; Silva, Pedro L; Rzezinski, Andréia F; Abrantes, Simone; Santiago, Viviane R; Nardelli, Liliane; Santos, Raquel S; Barbosa, Carolina M L; Morales, Marcelo M; Zin, Walter A; Amato, Marcelo B P; Capelozzi, Vera L; Pelosi, Paolo; Rocco, Patricia R M

    2009-03-01

    To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Prospective, randomized, and controlled experimental study. University research laboratory. Wistar rats were randomly assigned to control (C) [saline (0.1 mL), intraperitoneally] and ALI [paraquat (15 mg/kg), intraperitoneally] groups. After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H2O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (DeltaP2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and DeltaP2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and DeltaP2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful.

  10. Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury.

    PubMed

    Rotta, A T; Gunnarsson, B; Fuhrman, B P; Hernan, L J; Steinhorn, D M

    2001-11-01

    To determine the impact of different protective and nonprotective mechanical ventilation strategies on the degree of pulmonary inflammation, oxidative damage, and hemodynamic stability in a saline lavage model of acute lung injury. A prospective, randomized, controlled, in vivo animal laboratory study. Animal research facility of a health sciences university. Forty-six New Zealand White rabbits. Mature rabbits were instrumented with a tracheostomy and vascular catheters. Lavage-injured rabbits were randomized to receive conventional ventilation with either a) low peak end-expiratory pressure (PEEP; tidal volume of 10 mL/kg, PEEP of 2 cm H2O); b) high PEEP (tidal volume of 10 mL/kg, PEEP of 10 cm H2O); c) low tidal volume with PEEP above Pflex (open lung strategy, tidal volume of 6 mL/kg, PEEP set 2 cm H2O > Pflex); or d) high-frequency oscillatory ventilation. Animals were ventilated for 4 hrs. Lung lavage fluid and tissue samples were obtained immediately after animals were killed. Lung lavage fluid was assayed for measurements of total protein, elastase activity, tumor necrosis factor-alpha, and malondialdehyde. Lung tissue homogenates were assayed for measurements of myeloperoxidase activity and malondialdehyde. The need for inotropic support was recorded. Animals that received a lung protective strategy (open lung or high-frequency oscillatory ventilation) exhibited more favorable oxygenation and lung mechanics compared with the low PEEP and high PEEP groups. Animals ventilated by a lung protective strategy also showed attenuation of inflammation (reduced tracheal fluid protein, tracheal fluid elastase, tracheal fluid tumor necrosis factor-alpha, and pulmonary leukostasis). Animals treated with high-frequency oscillatory ventilation had attenuated oxidative injury to the lung and greater hemodynamic stability compared with the other experimental groups. Both lung protective strategies were associated with improved oxygenation, attenuated inflammation, and

  11. Injurious mechanical ventilation in the normal lung causes a progressive pathologic change in dynamic alveolar mechanics.

    PubMed

    Pavone, Lucio A; Albert, Scott; Carney, David; Gatto, Louis A; Halter, Jeffrey M; Nieman, Gary F

    2007-01-01

    Acute respiratory distress syndrome causes a heterogeneous lung injury, and without protective mechanical ventilation a secondary ventilator-induced lung injury can occur. To ventilate noncompliant lung regions, high inflation pressures are required to 'pop open' the injured alveoli. The temporal impact, however, of these elevated pressures on normal alveolar mechanics (that is, the dynamic change in alveolar size and shape during ventilation) is unknown. In the present study we found that ventilating the normal lung with high peak pressure (45 cmH(2)0) and low positive end-expiratory pressure (PEEP of 3 cmH(2)O) did not initially result in altered alveolar mechanics, but alveolar instability developed over time. Anesthetized rats underwent tracheostomy, were placed on pressure control ventilation, and underwent sternotomy. Rats were then assigned to one of three ventilation strategies: control group (n = 3, P control = 14 cmH(2)O, PEEP = 3 cmH(2)O), high pressure/low PEEP group (n = 6, P control = 45 cmH(2)O, PEEP = 3 cmH(2)O), and high pressure/high PEEP group (n = 5, P control = 45 cmH(2)O, PEEP = 10 cmH(2)O). In vivo microscopic footage of subpleural alveolar stability (that is, recruitment/derecruitment) was taken at baseline and than every 15 minutes for 90 minutes following ventilator adjustments. Alveolar recruitment/derecruitment was determined by measuring the area of individual alveoli at peak inspiration (I) and end expiration (E) by computer image analysis. Alveolar recruitment/derecruitment was quantified by the percentage change in alveolar area during tidal ventilation (%I - E Delta). Alveoli were stable in the control group for the entire experiment (low %I - E Delta). Alveoli in the high pressure/low PEEP group were initially stable (low %I - E Delta), but with time alveolar recruitment/derecruitment developed. The development of alveolar instability in the high pressure/low PEEP group was associated with histologic lung injury. A large change in

  12. Optimization of pressure settings during adaptive servo-ventilation support using real-time heart rate variability assessment: initial case report.

    PubMed

    Imamura, Teruhiko; Nitta, Daisuke; Kinugawa, Koichiro

    2017-01-05

    Adaptive servo-ventilation (ASV) therapy is a recent non-invasive positive pressure ventilation therapy that was developed for patients with heart failure (HF) refractory to optimal medical therapy. However, it is likely that ASV therapy at relatively higher pressure setting worsens some of the patients' prognosis compared with optimal medical therapy. Therefore, identification of optimal pressure settings of ASV therapy is warranted. We present the case of a 42-year-old male with HF, which was caused by dilated cardiomyopathy, who was admitted to our institution for evaluating his eligibility for heart transplantation. To identify the optimal pressure setting [peak end-expiratory pressure (PEEP) ramp test], we performed an ASV support test, during which the PEEP settings were set at levels ranging from 4 to 8 mmHg, and a heart rate variability (HRV) analysis using the MemCalc power spectral density method. Clinical parameters varied dramatically during the PEEP ramp test. Over incremental PEEP levels, pulmonary capillary wedge pressure, cardiac index and high-frequency level (reflecting parasympathetic activity) decreased; however, the low-frequency level increased along with increase in plasma noradrenaline concentrations. An inappropriately high PEEP setting may stimulate sympathetic nerve activity accompanied by decreased cardiac output. This was the first report on the PEEP ramp test during ASV therapy. Further research is warranted to determine whether use of optimal pressure settings using HRV analyses may improve the long-term prognosis of such patients.

  13. Automated Erosion System to Protect Highway Bridge Crossings at Abutments

    DOT National Transportation Integrated Search

    2010-06-01

    A new instrument (Photo-Electronic Erosion Pin, or PEEP) was examined in collecting field data and remotely monitoring bank erosion near bridge abutments during floods. The performance of PEEPs was evaluated through a detailed field study to determin...

  14. Evaluation of lung recruitment maneuvers in acute respiratory distress syndrome using computer simulation.

    PubMed

    Das, Anup; Cole, Oana; Chikhani, Marc; Wang, Wenfei; Ali, Tayyba; Haque, Mainul; Bates, Declan G; Hardman, Jonathan G

    2015-01-12

    Direct comparison of the relative efficacy of different recruitment maneuvers (RMs) for patients with acute respiratory distress syndrome (ARDS) via clinical trials is difficult, due to the heterogeneity of patient populations and disease states, as well as a variety of practical issues. There is also significant uncertainty regarding the minimum values of positive end-expiratory pressure (PEEP) required to ensure maintenance of effective lung recruitment using RMs. We used patient-specific computational simulation to analyze how three different RMs act to improve physiological responses, and investigate how different levels of PEEP contribute to maintaining effective lung recruitment. We conducted experiments on five 'virtual' ARDS patients using a computational simulator that reproduces static and dynamic features of a multivariable clinical dataset on the responses of individual ARDS patients to a range of ventilator inputs. Three recruitment maneuvers (sustained inflation (SI), maximal recruitment strategy (MRS) followed by a titrated PEEP, and prolonged recruitment maneuver (PRM)) were implemented and evaluated for a range of different pressure settings. All maneuvers demonstrated improvements in gas exchange, but the extent and duration of improvement varied significantly, as did the observed mechanism of operation. Maintaining adequate post-RM levels of PEEP was seen to be crucial in avoiding cliff-edge type re-collapse of alveolar units for all maneuvers. For all five patients, the MRS exhibited the most prolonged improvement in oxygenation, and we found that a PEEP setting of 35 cm H2O with a fixed driving pressure of 15 cm H2O (above PEEP) was sufficient to achieve 95% recruitment. Subsequently, we found that PEEP titrated to a value of 16 cm H2O was able to maintain 95% recruitment in all five patients. There appears to be significant scope for reducing the peak levels of PEEP originally specified in the MRS and hence to avoid exposing the lung to

  15. A Case of Shunting Postoperative Patent Foramen Ovale Under Mechanical Ventilation Controlled by Different Ventilator Settings.

    PubMed

    Pragliola, Claudio; Di Michele, Sara; Galzerano, Domenico

    2017-06-07

    A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H 2 O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H 2 O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  16. Cardiopulmonary function after pulmonary contusion and partial liquid ventilation.

    PubMed

    Moomey, C B; Fabian, T C; Croce, M A; Melton, S M; Proctor, K G

    1998-08-01

    To compare the effects of mechanical ventilation with either positive end-expiratory pressure (PEEP) or partial liquid ventilation (PLV) on cardiopulmonary function after severe pulmonary contusion. Mongrel pigs (32 +/- 1 kg) were anesthetized, paralyzed, and mechanically ventilated (8-10 mL/kg tidal volume; 12 breaths/min; FiO2 = 0.5). Systemic hemodynamics and pulmonary function were measured for 7 hours after a captive bolt gun delivered a blunt injury to the right chest. After 5 hours, FiO2 was increased to 1.0 and either PEEP (n = 7) in titrated increments to 25 cm H2O or PLV with perflubron (LiquiVent, 30 mL/kg, endotracheal) and no PEEP (n = 7) was administered for 2 hours. Two control groups received injury without treatment (n = 6) or no injury with PLV (n = 3). Fluids were liberalized with PEEP versus PLV (27 +/- 3 vs. 18 +/- 2 mL.kg-1.h-1) to maintain cardiac filling pressures. Before treatment at 5 hours after injury, physiologic dead space fraction (30 +/- 4%), pulmonary vascular resistance (224 +/- 20% of baseline), and airway resistance (437 +/- 110% of baseline) were all increased (p < 0.05). In addition, PaO2/FiO2 had decreased to 112 +/- 18 mm Hg, compliance was depressed to 11 +/- 1 mL/cm H2O (36 +/- 3% of baseline), and shunt fraction was increased to 22 +/- 4% (all p < 0.05). Blood pressure and cardiac index remained stable relative to baseline, but stroke index and systemic oxygen delivery were depressed by 15 to 30% (both p < 0.05). After 2 hours of treatment with PEEP versus PLV, PO2/FiO2 was higher (427 +/- 20 vs. 263 +/- 37) and dead space ventilation was lower (4 +/- 3 vs. 28 +/- 7%) (both p < 0.05), whereas compliance tended to be higher (26 +/- 2 vs. 20 +/- 2) and shunt fraction tended to be lower (0 +/- 0 vs. 7 +/- 4). With PEEP versus PLV, however, cardiac index, stroke index, and systemic oxygen delivery were 30 to 60% lower (all p < 0.05). Furthermore, although contused lungs showed similar damage with either treatment, the

  17. The Peep Show

    ERIC Educational Resources Information Center

    Gamble, David L.

    2010-01-01

    Three years ago, the author and Linda Arbuckle (University of Florida ceramic professor and internationally known majolica clay artist) were on the phone discussing how electric kilns just don't have any artistic design flair to them. The round kiln has basic properties that allow it to function properly, but its looks are far from exciting. They…

  18. The effects of intraoperative lung protective ventilation with positive end-expiratory pressure on blood loss during hepatic resection surgery: A secondary analysis of data from a published randomised control trial (IMPROVE).

    PubMed

    Neuschwander, Arthur; Futier, Emmanuel; Jaber, Samir; Pereira, Bruno; Eurin, Mathilde; Marret, Emmanuel; Szymkewicz, Olga; Beaussier, Marc; Paugam-Burtz, Catherine

    2016-04-01

    During high-risk abdominal surgery the use of a multi-faceted lung protective ventilation strategy composed of low tidal volumes, positive end-expiratory pressure (PEEP) and recruitment manoeuvres, has been shown to improve clinical outcomes. It has been speculated, however, that mechanical ventilation using PEEP might increase intraoperative bleeding during liver resection. To study the impact of mechanical ventilation with PEEP on bleeding during hepatectomy. Post-hoc analysis of a randomised controlled trial. Seven French university teaching hospitals from January 2011 to August 2012. Patients scheduled for liver resection surgery. In the Intraoperative Protective Ventilation trial, patients scheduled for major abdominal surgery were randomly assigned to mechanical ventilation using low tidal volume, PEEP between 6 and 8  cmH2O and recruitment manoeuvres (lung protective ventilation strategy) or higher tidal volume, zero PEEP and no recruitment manoeuvres (non-protective ventilation strategy). The primary endpoint was intraoperative blood loss volume. A total of 79 (19.8%) patients underwent liver resections (41 in the lung protective and 38 in the non-protective group). The median (interquartile range) amount of intraoperative blood loss was 500 (200 to 800)  ml and 275 (125 to 800)  ml in the non-protective and lung protective ventilation groups, respectively (P = 0.47). Fourteen (35.0%) and eight (21.5%) patients were transfused in the non-protective and lung protective groups, respectively (P = 0.17), without a statistically significant difference in the median (interquartile range) number of red blood cells units transfused [2.5 (2 to 4) units and 3 (2 to 6) units in the two groups, respectively; P = 0.54]. During hepatic surgery, mechanical ventilation using PEEP within a multi-faceted lung protective strategy was not associated with increased bleeding compared with non-protective ventilation using zero PEEP. The current study was not

  19. Recruitment Maneuver Does not Increase the Risk of Ventilator Induced Lung Injury

    PubMed Central

    Akıncı, İbrahim Özkan; Atalan, Korkut; Tuğrul, Simru; Özcan, Perihan Ergin; Yılmazbayhan, Dilek; Kıran, Bayram; Basel, Ahmet; Telci, Lutfi; Çakar, Nahit

    2013-01-01

    Background: Mechanical ventilation (MV) may induce lung injury. Aims: To assess and evaluate the role of different mechanical ventilation strategies on ventilator-induced lung injury (VILI) in comparison to a strategy which includes recruitment manoeuvre (RM). Study design: Randomized animal experiment. Methods: Thirty male Sprague-Dawley rats were anaesthetised, tracheostomised and divided into 5 groups randomly according to driving pressures; these were mechanically ventilated with following peak alveolar opening (Pao) and positive end-expiratory pressures (PEEP) for 1 hour: Group 15-0: 15 cmH2O Pao and 0 cmH2O PEEP; Group 30-10: 30 cmH2O Pao and 10 cmH2O PEEP; Group 30-5: 30 cmH2O Pao and 5 cmH2O PEEP; Group 30-5&RM: 30 cmH2O Pao and 5 cmH2O PEEP with additional 45 cmH2O CPAP for 30 seconds in every 15 minutes; Group 45-0: 45 cmH2O Pao and 0 cmH2O PEEP Before rats were sacrificed, blood samples were obtained for the evaluation of cytokine and chemokine levels; then, the lungs were subsequently processed for morphologic evaluation. Results: Oxygenation results were similar in all groups; however, the groups were lined as follows according to the increasing severity of morphometric evaluation parameters: Group 15-0: (0±0.009) < Group 30-10: (0±0.14) < Group 30-5&RM: (1±0.12) < Group 30-5: (1±0.16) < Group 45-0: (2±0.16). Besides, inflammatory responses were the lowest in 30-5&RM group compared to all other groups. TNF-α, IL-1β, IL-6, MCP-1 levels were significantly different between group 30-5&RM and group 15-0 vs. group 45-0 in each group. Conclusion: RM with low PEEP reduces the risk of ventilator-induced lung injury with a lower release of systemic inflammatory mediators in response to mechanical ventilation. PMID:25207105

  20. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury.

    PubMed

    Wolthuis, Esther K; Choi, Goda; Dessing, Mark C; Bresser, Paul; Lutter, Rene; Dzoljic, Misa; van der Poll, Tom; Vroom, Margreeth B; Hollmann, Markus; Schultz, Marcus J

    2008-01-01

    Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without preexisting lung injury. Patients scheduled to undergo an elective surgical procedure (lasting > or = 5 h) were randomly assigned to mechanical ventilation with either higher tidal volumes of 12 ml/kg ideal body weight and no positive end-expiratory pressure (PEEP) or lower tidal volumes of 6 ml/kg and 10 cm H2O PEEP. After induction of anesthesia and 5 h thereafter, bronchoalveolar lavage fluid and/or blood was investigated for polymorphonuclear cell influx, changes in levels of inflammatory markers, and nucleosomes. Mechanical ventilation with lower tidal volumes and PEEP (n = 21) attenuated the increase of pulmonary levels of interleukin (IL)-8, myeloperoxidase, and elastase as seen with higher tidal volumes and no PEEP (n = 19). Only for myeloperoxidase, a difference was found between the two ventilation strategies after 5 h of mechanical ventilation (P < 0.01). Levels of tumor necrosis factor alpha, IL-1alpha, IL-1beta, IL-6, macrophage inflammatory protein 1alpha, and macrophage inflammatory protein 1beta in the bronchoalveolar lavage fluid were not affected by mechanical ventilation. Plasma levels of IL-6 and IL-8 increased with mechanical ventilation, but there were no differences between the two ventilation groups. The use of lower tidal volumes and PEEP may limit pulmonary inflammation in mechanically ventilated patients without preexisting lung injury. The specific contribution of both lower tidal volumes and PEEP on the protective effects of the lung should be further investigated.

  1. Comparison of static end-expiratory and effective lung volumes for gas exchange in healthy and surfactant-depleted lungs.

    PubMed

    Albu, Gergely; Wallin, Mats; Hallbäck, Magnus; Emtell, Per; Wolf, Andrew; Lönnqvist, Per-Arne; Göthberg, Sylvia; Peták, Ferenc; Habre, Walid

    2013-07-01

    Effective lung volume (ELV) for gas exchange is a new measure that could be used as a real-time guide during controlled mechanical ventilation. The authors established the relationships of ELV to static end-expiratory lung volume (EELV) with varying levels of positive end-expiratory pressure (PEEP) in healthy and surfactant-depleted rabbit lungs. Nine rabbits were anesthetized and ventilated with a modified volume-controlled mode where periods of five consecutive alterations in inspiratory/expiratory ratio (1:2-1.5:1) were imposed to measure ELV from the corresponding carbon dioxide elimination traces. EELV and the lung clearance index were concomitantly determined by helium wash-out technique. Airway and tissue mechanics were assessed by using low-frequency forced oscillations. Measurements were collected at PEEP 0, 3, 6, and 9 cm H2O levels under control condition and after surfactant depletion by whole-lung lavage. ELV was greater than EELV at all PEEP levels before lavage, whereas there was no evidence for a difference in the lung volume indices after surfactant depletion at PEEP 6 or 9 cm H2O. Increasing PEEP level caused significant parallel increases in both ELV and EELV levels, decreases in ventilation heterogeneity, and improvement in airway and tissue mechanics under control condition and after surfactant depletion. ELV and EELV exhibited strong and statistically significant correlations before (r=0.84) and after lavage (r=0.87). The parallel changes in ELV and EELV with PEEP in healthy and surfactant-depleted lungs support the clinical value of ELV measurement as a bedside tool to estimate dynamic changes in EELV in children and infants.

  2. A clinical classification of the acute respiratory distress syndrome for predicting outcome and guiding medical therapy*.

    PubMed

    Villar, Jesús; Fernández, Rosa L; Ambrós, Alfonso; Parra, Laura; Blanco, Jesús; Domínguez-Berrot, Ana M; Gutiérrez, José M; Blanch, Lluís; Añón, José M; Martín, Carmen; Prieto, Francisca; Collado, Javier; Pérez-Méndez, Lina; Kacmarek, Robert M

    2015-02-01

    Current in-hospital mortality of the acute respiratory distress syndrome (ARDS) is above 40%. ARDS outcome depends on the lung injury severity within the first 24 hours of ARDS onset. We investigated whether two widely accepted cutoff values of PaO2/FIO2 and positive end-expiratory pressure (PEEP) would identify subsets of patients with ARDS for predicting outcome and guiding therapy. A 16-month (September 2008 to January 2010) prospective, multicenter, observational study. Seventeen multidisciplinary ICUs in Spain. We studied 300 consecutive, mechanically ventilated patients meeting American-European Consensus Conference criteria for ARDS (PaO2/FIO2 ≤ 200 mm Hg) on PEEP greater than or equal to 5 cm H2O, and followed up until hospital discharge. None. Based on threshold values for PaO2/FIO2 (150 mm Hg) and PEEP (10 cm H2O) at ARDS onset and at 24 hours, we assigned patients to four categories: group I (PaO2/FIO2 ≥ 150 on PEEP < 10), group II (PaO2/FIO2 ≥ 150 on PEEP ≥ 10), group III (PaO2/FIO2 < 150 on PEEP < 10), and group IV (PaO2/FIO2 < 150 on PEEP ≥ 10). The primary outcome was all-cause in-hospital mortality. Overall hospital mortality was 46.3%. Although at study entry, patients with PaO2/FIO2 less than 150 had a higher mortality than patients with a PaO2/FIO2 greater than or equal to 150 (p = 0.044), there was minimal variability in mortality among the four groups (p = 0.186). However, classification of patients in each group changed markedly after 24 hours of usual care. Group categorization at 24 hours provided a strong association with in-hospital mortality (p < 0.00001): group I had the lowest mortality (23.1%), whereas group IV had the highest mortality (60.3%). The degree of lung dysfunction established by a PaO2/FIO2 of 150 mm Hg and a PEEP of 10 cm H2O demonstrated that ARDS is not a homogeneous disorder. Rather, it is a series of four subsets that should be considered for enrollment in clinical trials and for guiding therapy. A major

  3. Alveolar edema dispersion and alveolar protein permeability during high volume ventilation: effect of positive end-expiratory pressure.

    PubMed

    de Prost, Nicolas; Roux, Damien; Dreyfuss, Didier; Ricard, Jean-Damien; Le Guludec, Dominique; Saumon, Georges

    2007-04-01

    To evaluate whether PEEP affects intrapulmonary alveolar edema liquid movement and alveolar permeability to proteins during high volume ventilation. Experimental study in an animal research laboratory. 46 male Wistar rats. A (99m)Tc-labeled albumin solution was instilled in a distal airway to produce a zone of alveolar flooding. Conventional ventilation (CV) was applied for 30 min followed by various ventilation strategies for 3 h: CV, spontaneous breathing, and high volume ventilation with different PEEP levels (0, 6, and 8 cmH(2)O) and different tidal volumes. Dispersion of the instilled liquid and systemic leakage of (99m)Tc-albumin from the lungs were studied by scintigraphy. The instillation protocol produced a zone of alveolar flooding that stayed localized during CV or spontaneous breathing. High volume ventilation dispersed alveolar liquid in the lungs. This dispersion was prevented by PEEP even when tidal volume was the same and thus end-inspiratory pressure higher. High volume ventilation resulted in the leakage of instilled (99m)Tc-albumin from the lungs. This increase in alveolar albumin permeability was reduced by PEEP. Albumin permeability was more affected by the amplitude of tidal excursions than by overall lung distension. PEEP prevents the dispersion of alveolar edema liquid in the lungs and lessens the increase in alveolar albumin permeability due to high volume ventilation.

  4. Compliance-guided versus FiO2-driven positive-end expiratory pressure in patients with moderate or severe acute respiratory distress syndrome according to the Berlin definition.

    PubMed

    Pintado, M-C; de Pablo, R; Trascasa, M; Milicua, J-M; Sánchez-García, M

    To study the effect of setting positive end-expiratory pressure (PEEP) in an individualized manner (based on highest static compliance) compared to setting PEEP according to FiO 2 upon mortality at 28 and 90 days, in patients with different severity acute respiratory distress syndrome (ARDS). A Spanish medical-surgical ICU. A post hoc analysis of a randomized controlled pilot study. Patients with ARDS. Ventilation with low tidal volumes and pressure limitation at 30cmH 2 O, randomized in two groups according to the method used to set PEEP: FiO 2 -guided PEEP group according to FiO 2 applied and compliance-guided group according to the highest compliance. Demographic data, risk factors and severity of ARDS, APACHE II and SOFA scores, daily Lung Injury Score, ventilatory measurements, ICU and hospital stay, organ failure and mortality at day 28 and 90 after inclusion. A total of 159 patients with ARDS were evaluated, but just 70 patients were included. Severe ARDS patients showed more organ dysfunction-free days at 28 days (12.83±10.70 versus 3.09±7.23; p=0.04) and at 90 days (6.73±22.31 vs. 54.17±42.14, p=0.03), and a trend toward lower 90-days mortality (33.3% vs. 90.9%, p=0.02), when PEEP was applied according to the best static compliance. Patients with moderate ARDS did not show these effects. In patients with severe ARDS, individualized PEEP selection based on the best static compliance was associated to lower mortality at 90 days, with an increase in organ dysfunction-free days at 28 and 90 days. Copyright © 2016 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  5. Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs.

    PubMed

    Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise

    2010-06-01

    Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P < 0.001). Cytokines in BAL were similar in groups H-Vt/3 and L-Vt/3. Group H-Vt/3 had a significantly lower lung injury score than groups L-Vt/3 and L-Vt/10. Comparing intraoperative strategies, ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.

  6. Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome.

    PubMed

    Williams, E M; Viale, J P; Hamilton, R M; McPeak, H; Sutton, L; Hahn, C E

    2000-09-01

    Tidal ventilation causes within-breath oscillations in alveolar oxygen concentration, with an amplitude which depends on the prevailing ventilator settings. These alveolar oxygen oscillations are transmitted to arterial oxygen tension, PaO2, but with an amplitude which now depends upon the magnitude of venous admixture or true shunt, QS/QT. We investigated the effect of positive end-expiratory pressure (PEEP) on the amplitude of the PaO2 oscillations, using an atelectasis model of shunt. Blood PaO2 was measured on-line with an intravascular PaO2 sensor, which had a 2-4 s response time (10-90%). The magnitude of the time-varying PaO2 oscillation was titrated against applied PEEP while tidal volume, respiratory rate and inspired oxygen concentration were kept constant. The amplitude of the PaO2 oscillation, delta PaO2, and the mean PaO2 value varied with the level of PEEP applied. At zero PEEP, both the amplitude and the mean were at their lowest values. As PEEP was increased to 1.5 kPa, both delta PaO2 and the mean PaO2 increased to a maximum. Thereafter, the mean PaO2 increased but delta PaO2 decreased. Clear oscillations of PaO2 were seen even at the lowest mean PaO2, 9.5 kPa. Conventional respiratory models of venous admixture predict that these PaO2 oscillations will be reduced by the steep part of the oxyhaemoglobin dissociation curve if a constant pulmonary shunt exists throughout the whole respiratory cycle. The facts that the PaO2 oscillations occurred at all mean PaO2 values and that their amplitude increased with increasing PEEP suggest that QS/QT, in the atelectasis model, varies between end-expiration and end-inspiration, having a much lower value during inspiration than during expiration.

  7. Intraoperative ventilatory strategies for prevention of pulmonary atelectasis in obese patients undergoing laparoscopic bariatric surgery.

    PubMed

    Talab, Hesham F; Zabani, Ibrahim Ali; Abdelrahman, Hassan Saad; Bukhari, Waleed L; Mamoun, Irfan; Ashour, Majed A; Sadeq, Bakr Bin; El Sayed, Sameh Ibrahim

    2009-11-01

    Atelectasis occurs regularly after induction of general anesthesia, persists postoperatively, and may contribute to significant postoperative morbidity and additional health care costs. Laparoscopic surgery has been reported to be associated with an increased incidence of postoperative atelectasis. It has been shown that during general anesthesia, obese patients have a greater risk of atelectasis than nonobese patients. Preventing atelectasis is important for all patients but is especially important when caring for obese patients. We randomly allocated 66 adult obese patients with a body mass index between 30 and 50 kg/m(2) scheduled to undergo laparoscopic bariatric surgery into 3 groups. According to the recruitment maneuver used, the zero end-expiratory pressure (ZEEP) group (n = 22) received the vital capacity maneuver (VCM) maintained for 7-8 s applied immediately after intubation plus ZEEP; the positive end-expiratory pressure (PEEP) 5 group (n = 22) received the VCM maintained for 7-8 s applied immediately after intubation plus 5 cm H(2)O of PEEP; and the PEEP 10 group (n = 22) received the VCM maintained for 7-8 s applied immediately after intubation plus 10 cm H(2)O of PEEP. All other variables (e.g., anesthetic and surgical techniques) were the same for all patients. Heart rate, noninvasive mean arterial blood pressure, arterial oxygen saturation, and alveolar-arterial Pao(2) gradient (A-a Pao(2)) were measured intraoperatively and postoperatively in the postanesthesia care unit (PACU). Length of stay in the PACU and the use of a nonrebreathing O(2) mask (100% Fio(2)) or reintubation were also recorded. A computed tomographic scan of the chest was performed preoperatively and postoperatively after discharge from the PACU to evaluate lung atelectasis. Patients in the PEEP 10 group had better oxygenation both intraoperatively and postoperatively in the PACU, lower atelectasis score on chest computed tomographic scan, and less postoperative pulmonary

  8. Bench performance of ventilators during simulated paediatric ventilation.

    PubMed

    Park, M A J; Freebairn, R C; Gomersall, C D

    2013-05-01

    This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.

  9. Setting ventilation parameters guided by electrical impedance tomography in an animal trial of acute respiratory distress syndrome

    NASA Astrophysics Data System (ADS)

    Czaplik, Michael; Biener, Ingeborg; Leonhardt, Steffen; Rossaint, Rolf

    2014-03-01

    Since mechanical ventilation can cause harm to lung tissue it should be as protective as possible. Whereas numerous options exist to set ventilator parameters, an adequate monitoring is lacking up to date. The Electrical Impedance Tomography (EIT) provides a non-invasive visualization of ventilation which is relatively easy to apply and commercially available. Although there are a number of published measures and parameters derived from EIT, it is not clear how to use EIT to improve clinical outcome of e.g. patients suffering from acute respiratory distress syndrome (ARDS), a severe disease with a high mortality rate. On the one hand, parameters should be easy to obtain, on the other hand clinical algorithms should consider them to optimize ventilator settings. The so called Global inhomogeneity (GI) index bases on the fact that ARDS is characterized by an inhomogeneous injury pattern. By applying positive endexpiratory pressures (PEEP), homogeneity should be attained. In this study, ARDS was induced by a double hit procedure in six pigs. They were randomly assigned to either the EIT or the control group. Whereas in the control group the ARDS network table was used to set the PEEP according to the current inspiratory oxygen fraction, in the EIT group the GI index was calculated during a decremental PEEP trial. PEEP was kept when GI index was lowest. Interestingly, PEEP was significantly higher in the EIT group. Additionally, two of these animals died ahead of the schedule. Obviously, not only homogeneity of ventilation distribution matters but also limitation of over-distension.

  10. The effectiveness of nasal mask vs face mask ventilation in anesthetized, apneic pediatric subjects over 2 years of age: a randomized controlled trial.

    PubMed

    Itagaki, Taiga; Gubin, Tatyana A; Sayal, Puneet; Jiang, Yandong; Kacmarek, Robert M; Anderson, Thomas Anthony

    2016-02-01

    We hypothesized that anesthetized, apneic children could be ventilated equivalently or more efficiently by nasal mask ventilation (NMV) than face mask ventilation (FMV). The aim of this randomized controlled study was to test this hypothesis by comparing the expiratory tidal volume (Vte) between NMV and FMV. After the induction of anesthesia, 41 subjects, 3-17 years of age without anticipated difficult mask ventilation, were randomly assigned to receive either NMV or FMV with neck extension. Both groups were ventilated with pressure control ventilation (PCV) at 20 cmH2 O of peak inspiratory pressure (PIP) with positive end-expiratory pressure (PEEP) levels of 0, 5, and 10 cmH2 O. An additional mouth closing maneuver (MCM) was applied for the NMV group. The Vte was higher in the FMV group compared with the NMV group (median difference [95% CI]: 8.4 [5.5-11.6] ml·kg(-1) ; P < 0.001) when MCM was not applied. NMV achieved less PEEP than FMV (median difference [95% CI]: 5.0 [4.3-5.3] cmH2 O at 10 cmH2 O; P < 0.001) though both groups achieved the set PIP level. In the NMV group, MCM markedly increased Vte (median increase [95% CI]: 5.9 [2.5-9.0] ml·kg(-1) ; P < 0.005) and PEEP (median increase [95% CI]: 5.0 [0.6-8.6] cmH2 O at 10 cmH2 O; P < 0.005); however, PEEP was highly variable and lower than that of FMV (median difference [95% CI]: 2.5 [0.8-8.5] cmH2 O at 10 cmH2 O; P < 0.05). In anesthetized, apneic children greater than 2 years of age ventilated with an anesthesia ventilator and neck extension, FMV established a greater Vte than NMV regardless of mouth status. NMV could not maintain the set PEEP level due to an air leak from the mouth. The MCM increased the Vte and PEEP. © 2016 John Wiley & Sons Ltd.

  11. Ultrasonic monitoring in the assessment of pulmonary recruitment and the best positive end-expiratory pressure.

    PubMed

    Tang, Ke-Qiang; Yang, Shao-Ling; Zhang, Bin; Liu, Hong-Xiang; Ye, Dong-Ying; Zhang, Hong-Ze; Ma, Shuang

    2017-09-01

    The aim of this study was to explore the clinical value of ultrasonic monitoring in the assessment of pulmonary recruitment and the best positive end-expiratory pressure (PEEP).Between January 2015 and June 2017, 40 patients with acute respiratory distress syndrome in our hospital were randomly divided into 2 groups: ultrasound group (ULS group; n = 20) and oxygenation group (OXY group; n = 20). The PEEP incremental method was used to perform recruitment maneuvers. Ultrasound scoring and the oxygenation method were used to evaluate the pulmonary recruitment endpoint. The best PEEP was chosen by ultrasound scoring and the oxygenation method after achieving the pulmonary recruitment endpoint and sustaining it for 15 minutes.The oxygenation index, PEEP, peak airway pressure (Ppeak), mean airway pressure (Pmean), and dynamic compliance (Cdyn) in the OXY group were significantly lower than those in the ULS group (P < .05) at the pulmonary recruitment endpoint; however, there was no statistical significance in the mean arterial blood pressure (MAP) or heart rate (HR) (P > .05). The best PEEPs in the OXY and ULS groups were 13.1 ± 3.1 and 15.7 ± 4.2 cmH2O, respectively, with a significant difference between the 2 groups (t = 2.227, P = .016). Compared with the basal state, the Cdyn, oxygenation index, Pmean, and Ppeak in both groups significantly increased after pulmonary recruitment (P < .05). Furthermore, the Cdyn and oxygenation index in the ULS group were significantly higher than those in the OXY group after pulmonary recruitment (P < .05). The HR in both groups significantly increased, and the MAP significantly decreased. Two hours after recruitment, the HR and MAP returned to near basal levels without a significant difference between the 2 groups (P > .05).Lung ultrasound can be used to detect the endpoint of lung recruitment and the best PEEP, with good effects on lung compliance and oxygenation improvement.

  12. The Use of ATP-MgCl2 in the Treatment of Injury and Shock.

    DTIC Science & Technology

    1986-03-11

    that it requires mitochondrially produced ATP for its operation. Studies of the hemodynamic effects of ATP-MgCl 2 infusion in anesthetized normal and...8-14 1. LUNG STUDIES a) The salutary effects of positive end-expiratory pressure (PEEP) in experimentally-induced Pseudomonas pneumonia...salutary effects of positive end-expiratory pressure (PEEP) in experimentally induced Pseudomonas pneumonia." Anesthesia and Analgesia 58:2C8-215, 1979. 37

  13. Inhibitory input from slowly adapting lung stretch receptors to retrotrapezoid nucleus chemoreceptors

    PubMed Central

    Moreira, Thiago S; Takakura, Ana C; Colombari, Eduardo; West, Gavin H; Guyenet, Patrice G

    2007-01-01

    The retrotrapezoid nucleus (RTN) contains CO2-activated interneurons with properties consistent with central respiratory chemoreceptors. These neurons are glutamatergic and express the transcription factor Phox2b. Here we tested whether RTN neurons receive an input from slowly adapting pulmonary stretch receptors (SARs) in halothane-anaesthetized ventilated rats. In vagotomized rats, RTN neurons were inhibited to a variable extent by stimulating myelinated vagal afferents using the lowest intensity needed to inhibit the phrenic nerve discharge (PND). In rats with intact vagus nerves, RTN neurons were inhibited, also to a variable extent, by increasing positive end-expiratory pressure (PEEP; 2–6 cmH2O). The cells most sensitive to PEEP were inhibited during each lung inflation at rest and were instantly activated by stopping ventilation. Muscimol (GABA-A agonist) injection in or next to the solitary tract at area postrema level desynchronized PND from ventilation, eliminated the lung inflation-synchronous inhibition of RTN neurons and their steady inhibition by PEEP but did not change their CO2 sensitivity. Muscimol injection into the rostral ventral respiratory group eliminated PND but did not change RTN neuron response to either lung inflation, PEEP increases, vagal stimulation or CO2. Generalized glutamate receptor blockade with intracerebroventricular (i.c.v.) kynurenate eliminated PND and the response of RTN neurons to lung inflation but did not change their CO2 sensitivity. PEEP-sensitive RTN neurons expressed Phox2b. In conclusion, RTN chemoreceptors receive an inhibitory input from myelinated lung stretch receptors, presumably SARs. The lung input to RTN may be di-synaptic with inhibitory pump cells as sole interneurons. PMID:17255166

  14. [Alveolar ventilation and recruitment under lung protective ventilation].

    PubMed

    Putensen, Christian; Muders, Thomas; Kreyer, Stefan; Wrigge, Hermann

    2008-11-01

    Goal of mechanical ventilation is to improve gas exchange and reduce work of breathing without contributing to further lung injury. Besides providing adequate EELV and thereby arterial oxygenation PEEP in addition to a reduction in tidal volume is required to prevent cyclic alveolar collapse and tidal recruitment and hence protective mechanical ventilation. Currently, there is no consensus if and if yes at which price alveolar recruitment with high airway pressures should be intended ("open up the lung"), or if it is more important to reduce the mechanical stress and strain to the lungs as much as possible ("keep the lung closed"). Potential of alveolar recruitment differs from patient to patient but also between lung regions. Potential for recruitment depends probably more on regional lung mechanics - especially on lung elastance - than on the underlying disease. Based on available data neither high PEEP nor other methods used for alveolar recruitment could demonstrate a survival benefit in patients with ARDS. These results may support an individualized titration of PEEP or other manoeuvres used for recruitment taking into consideration the regional effects. Bedside imaging techniques allowing titration of PEEP or other manoeuvres to prevent end-expiratory alveolar collapse (tidal recruitment) and inspiratory overinflation may be a promising development.

  15. Individualized positive end-expiratory pressure application in patients with acute respiratory distress syndrome.

    PubMed

    Pintado, M C; de Pablo, R

    2014-11-01

    Current treatment of acute respiratory distress syndrome is based on ventilatory support with a lung protective strategy, avoiding the development of iatrogenic injury, including ventilator-induced lung injury. One of the mechanisms underlying such injury is atelectrauma, and positive end-expiratory pressure (PEEP) is advocated in order to avoid it. The indicated PEEP level has not been defined, and in many cases is based on the patient oxygen requirements for maintaining adequate oxygenation. However, this strategy does not consider the mechanics of the respiratory system, which varies in each patient and depends on many factors-including particularly the duration of acute respiratory distress syndrome. A review is therefore made of the different methods for adjusting PEEP, focusing on the benefits of individualized application. Copyright © 2013 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  16. Rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART): study protocol for a randomized controlled trial.

    PubMed

    2012-08-28

    Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH2O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure ≤30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this will represent a notable advance to

  17. Lung recruitment manoeuvres do not cause haemodynamic instability or oxidative stress but improve oxygenation and lung mechanics in a newborn animal model: an observational study.

    PubMed

    de la Osa, Agustín Mendiola; Garcia-Fernandez, Javier; Llorente-Cantarero, Francisco J; Gil-Campos, Mercedes; Muñoz-Villanueva, María C; De la Torre Aguilar, María J; de la Rosa, Ignacio Ibarra; Pérez-Navero, Juan L

    2014-09-01

    Lung recruitment manoeuvres in neonates during anaesthesia are not performed routinely due to concerns about causing barotrauma, haemodynamic instability and oxidative stress. To assess the influence of recruitment manoeuvres and positive end-expiratory pressure (PEEP) on haemodynamics, oxidative stress, oxygenation and lung mechanics. A prospective experimental study. Experimental Unit, La Paz University Hospital, Madrid, Spain. Eight newborn piglets (<48 h) with healthy lungs under general anaesthesia. The recruitment manoeuvres in pressure-controlled ventilation (PCV) were performed along with a constant driving pressure of 15 cmH2O. After the recruitment manoeuvres, PEEP was reduced in a stepwise fashion to find the maximal dynamic compliance step (maxCDyn-PEEP). Blood oxidative stress biomarkers (lipid peroxidation products, protein carbonyls, total glutathione, oxidised glutathione, reduced glutathione and activity of glutathione peroxidase) were analysed. Haemodynamic parameters, arterial partial pressure of oxygen (paO2), tidal volume (Vt), dynamic compliance (Cdyn) and oxidative stress biomarkers were measured. The recruitment manoeuvres did not induce barotrauma. Haemodynamic instability was not detected either in the maximum pressure step (overdistension step 5) or during the entire process. No substantial differences were observed in blood oxidative stress parameters analysed as compared with their baseline values (with 0 PEEP) or the values obtained 180 min after the onset of the recruitment manoeuvres (optimal PEEP). Significant maximal values were achieved in step 14 with an increase in paO2 (32.43 ± 8.48 vs. 40.39 ± 15.66 kPa; P = 0.037), Vt (47.75 ± 13.59 vs. 73.87 ± 13.56 ml; P = 0.006) and Cdyn (2.50 ± 0.64 vs. 4.75 ± 0.88 ml cmH2O; P < 0.001). Maximal dynamic compliance step (maxCdyn-PEEP) was 2 cmH2O. Recruitment manoeuvres in PCV with a constant driving pressure are a well tolerated open

  18. Mechanical ventilation strategies for intensive care unit patients without acute lung injury or acute respiratory distress syndrome: a systematic review and network meta-analysis.

    PubMed

    Guo, Lei; Wang, Weiwei; Zhao, Nana; Guo, Libo; Chi, Chunjie; Hou, Wei; Wu, Anqi; Tong, Hongshuang; Wang, Yue; Wang, Changsong; Li, Enyou

    2016-07-22

    It has been shown that the application of a lung-protective mechanical ventilation strategy can improve the prognosis of patients with acute lung injury (ALI) or acute respiratory distress syndrome (ARDS). However, the optimal mechanical ventilation strategy for intensive care unit (ICU) patients without ALI or ARDS is uncertain. Therefore, we performed a network meta-analysis to identify the optimal mechanical ventilation strategy for these patients. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, EMBASE, MEDLINE, CINAHL, and Web of Science for studies published up to July 2015 in which pulmonary compliance or the partial pressure of arterial oxygen/fraction of inspired oxygen (PaO2/FIO2) ratio was assessed in ICU patients without ALI or ARDS, who received mechanical ventilation via different strategies. The data for study characteristics, methods, and outcomes were extracted. We assessed the studies for eligibility, extracted the data, pooled the data, and used a Bayesian fixed-effects model to combine direct comparisons with indirect evidence. Seventeen randomized controlled trials including a total of 575 patients who received one of six ventilation strategies were included for network meta-analysis. Among ICU patients without ALI or ARDS, strategy C (lower tidal volume (VT) + higher positive end-expiratory pressure (PEEP)) resulted in the highest PaO2/FIO2 ratio; strategy B (higher VT + lower PEEP) was associated with the highest pulmonary compliance; strategy A (lower VT + lower PEEP) was associated with a shorter length of ICU stay; and strategy D (lower VT + zero end-expiratory pressure (ZEEP)) was associated with the lowest PaO2/FiO2 ratio and pulmonary compliance. For ICU patients without ALI or ARDS, strategy C (lower VT + higher PEEP) was associated with the highest PaO2/FiO2 ratio. Strategy B (higher VT + lower PEEP) was superior to the other strategies in improving pulmonary

  19. Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data.

    PubMed

    Neto, Ary Serpa; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; El-Tahan, Mohamed R; Ghamdi, Abdulmohsin A Al; Günay, Ersin; Jaber, Samir; Kokulu, Serdar; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Ranieri, V Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Amato, Marcelo B P; Costa, Eduardo L V; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2016-04-01

    Protective mechanical ventilation strategies using low tidal volume or high levels of positive end-expiratory pressure (PEEP) improve outcomes for patients who have had surgery. The role of the driving pressure, which is the difference between the plateau pressure and the level of positive end-expiratory pressure is not known. We investigated the association of tidal volume, the level of PEEP, and driving pressure during intraoperative ventilation with the development of postoperative pulmonary complications. We did a meta-analysis of individual patient data from randomised controlled trials of protective ventilation during general anesthaesia for surgery published up to July 30, 2015. The main outcome was development of postoperative pulmonary complications (postoperative lung injury, pulmonary infection, or barotrauma). We included data from 17 randomised controlled trials, including 2250 patients. Multivariate analysis suggested that driving pressure was associated with the development of postoperative pulmonary complications (odds ratio [OR] for one unit increase of driving pressure 1·16, 95% CI 1·13-1·19; p<0·0001), whereas we detected no association for tidal volume (1·05, 0·98-1·13; p=0·179). PEEP did not have a large enough effect in univariate analysis to warrant inclusion in the multivariate analysis. In a mediator analysis, driving pressure was the only significant mediator of the effects of protective ventilation on development of pulmonary complications (p=0·027). In two studies that compared low with high PEEP during low tidal volume ventilation, an increase in the level of PEEP that resulted in an increase in driving pressure was associated with more postoperative pulmonary complications (OR 3·11, 95% CI 1·39-6·96; p=0·006). In patients having surgery, intraoperative high driving pressure and changes in the level of PEEP that result in an increase of driving pressure are associated with more postoperative pulmonary complications. However

  20. Airway driving pressure and lung stress in ARDS patients.

    PubMed

    Chiumello, Davide; Carlesso, Eleonora; Brioni, Matteo; Cressoni, Massimo

    2016-08-22

    Lung-protective ventilation strategy suggests the use of low tidal volume, depending on ideal body weight, and adequate levels of PEEP. However, reducing tidal volume according to ideal body weight does not always prevent overstress and overstrain. On the contrary, titrating mechanical ventilation on airway driving pressure, computed as airway pressure changes from PEEP to end-inspiratory plateau pressure, equivalent to the ratio between the tidal volume and compliance of respiratory system, should better reflect lung injury. However, possible changes in chest wall elastance could affect the reliability of airway driving pressure. The aim of this study was to evaluate if airway driving pressure could accurately predict lung stress (the pressure generated into the lung due to PEEP and tidal volume). One hundred and fifty ARDS patients were enrolled. At 5 and 15 cmH2O of PEEP, lung stress, driving pressure, lung and chest wall elastance were measured. The applied tidal volume (mL/kg of ideal body weight) was not related to lung gas volume (r (2) = 0.0005 p = 0.772). Patients were divided according to an airway driving pressure lower and equal/higher than 15 cmH2O (the lower and higher airway driving pressure groups). At both PEEP levels, the higher airway driving pressure group had a significantly higher lung stress, respiratory system and lung elastance compared to the lower airway driving pressure group. Airway driving pressure was significantly related to lung stress (r (2) = 0.581 p < 0.0001 and r (2) = 0.353 p < 0.0001 at 5 and 15 cmH2O of PEEP). For a lung stress of 24 and 26 cmH2O, the optimal cutoff value for the airway driving pressure were 15.0 cmH2O (ROC AUC 0.85, 95 % CI = 0.782-0.922); and 16.7 (ROC AUC 0.84, 95 % CI = 0.742-0.936). Airway driving pressure can detect lung overstress with an acceptable accuracy. However, further studies are needed to establish if these limits could be used for ventilator settings.

  1. Investigation of continuous effect modifiers in a meta-analysis on higher versus lower PEEP in patients requiring mechanical ventilation--protocol of the ICEM study.

    PubMed

    Kasenda, Benjamin; Sauerbrei, Willi; Royston, Patrick; Briel, Matthias

    2014-05-20

    Categorizing an inherently continuous predictor in prognostic analyses raises several critical methodological issues: dependence of the statistical significance on the number and position of the chosen cut-point(s), loss of statistical power, and faulty interpretation of the results if a non-linear association is incorrectly assumed to be linear. This also applies to a therapeutic context where investigators of randomized clinical trials (RCTs) are interested in interactions between treatment assignment and one or more continuous predictors. Our goal is to apply the multivariable fractional polynomial interaction (MFPI) approach to investigate interactions between continuous patient baseline variables and the allocated treatment in an individual patient data meta-analysis of three RCTs (N = 2,299) from the intensive care field. For each study, MFPI will provide a continuous treatment effect function. Functions from each of the three studies will be averaged by a novel meta-analysis approach for functions. We will plot treatment effect functions separately for each study and also the averaged function. The averaged function with a related confidence interval will provide a suitable basis to assess whether a continuous patient characteristic modifies the treatment comparison and may be relevant for clinical decision-making. The compared interventions will be a higher or lower positive end-expiratory pressure (PEEP) ventilation strategy in patients requiring mechanical ventilation. The continuous baseline variables body mass index, PaO2/FiO2, respiratory compliance, and oxygenation index will be the investigated potential effect modifiers. Clinical outcomes for this analysis will be in-hospital mortality, time to death, time to unassisted breathing, and pneumothorax. This project will be the first meta-analysis to combine continuous treatment effect functions derived by the MFPI procedure separately in each of several RCTs. Such an approach requires individual

  2. Final postflight hardware evaluation report RSRM-32 (STS-57)

    NASA Technical Reports Server (NTRS)

    Nielson, Greg

    1993-01-01

    This document is the final report for the postflight assessment of the RSRM-32 (STS-57) flight set. This report presents the disassembly evaluations performed at the Thiokol facilities in Utah and is a continuation of the evaluations performed at KSC (TWR-64239). The PEEP for this assessment is outlined in TWR-50051, Revision B. The PEEP defines the requirements for evaluating RSRM hardware. Special hardware issues pertaining to this flight set requiring additional or modified assessment are outlined in TWR-64237. All observed hardware conditions were documented on PFOR's which are included in Appendix A. Observations were compared against limits defined in the PEEP. Any observation that was categorized as reportable or had no defined limits was documented on a preliminary PFAR by the assessment engineers. Preliminary PFAR's were reviewed by the Thiokol SPAT Executive Board to determine if elevation to PFAR's was required.

  3. Lung volumes and lung volume recruitment in ARDS: a comparison between supine and prone position.

    PubMed

    Aguirre-Bermeo, Hernan; Turella, Marta; Bitondo, Maddalena; Grandjean, Juan; Italiano, Stefano; Festa, Olimpia; Morán, Indalecio; Mancebo, Jordi

    2018-02-14

    The use of positive end-expiratory pressure (PEEP) and prone position (PP) is common in the management of severe acute respiratory distress syndrome patients (ARDS). We conducted this study to analyze the variation in lung volumes and PEEP-induced lung volume recruitment with the change from supine position (SP) to PP in ARDS patients. The investigation was conducted in a multidisciplinary intensive care unit. Patients who met the clinical criteria of the Berlin definition for ARDS were included. The responsible physician set basal PEEP. To avoid hypoxemia, FiO 2 was increased to 0.8 1 h before starting the protocol. End-expiratory lung volume (EELV) and functional residual capacity (FRC) were measured using the nitrogen washout/washin technique. After the procedures in SP, the patients were turned to PP and 1 h later the same procedures were made in PP. Twenty-three patients were included in the study, and twenty were analyzed. The change from SP to PP significantly increased FRC (from 965 ± 397 to 1140 ± 490 ml, p = 0.008) and EELV (from 1566 ± 476 to 1832 ± 719 ml, p = 0.008), but PEEP-induced lung volume recruitment did not significantly change (269 ± 186 ml in SP to 324 ± 188 ml in PP, p = 0.263). Dynamic strain at PEEP decreased with the change from SP to PP (0.38 ± 0.14 to 0.33 ± 0.13, p = 0.040). As compared to supine, prone position increases resting lung volumes and decreases dynamic lung strain.

  4. Dose-response comparisons of five lung surfactant factor (LSF) preparations in an animal model of adult respiratory distress syndrome (ARDS).

    PubMed Central

    Häfner, D.; Beume, R.; Kilian, U.; Krasznai, G.; Lachmann, B.

    1995-01-01

    1. We have examined the effects of five different lung surfactant factor (LSF) preparations in the rat lung lavage model. In this model repetitive lung lavage leads to lung injury with some similarities to adult respiratory distress syndrome with poor gas exchange and protein leakage into the alveolar spaces. These pathological sequelae can be reversed by LSF instillation soon after lavage. 2. The tested LSF preparations were: two bovine: Survanta and Alveofact: two synthetic: Exosurf and a protein-free phospholipid based LSF (PL-LSF) and one Recombinant LSF at doses of 25, 50 and 100 mg kg-1 body weight and an untreated control group. 3. Tracheotomized rats (10-12 per dose) were pressure-controlled ventilated (Siemens Servo Ventilator 900C) with 100% oxygen at a respiratory rate of 30 breaths min-1, inspiration expiration ratio of 1:2, peak inspiratory pressure (PIP) of 28 cmH2O at positive end-expiratory pressure (PEEP) of 8 cmH2O. Two hours after LSF administration, PEEP and in parallel PIP was reduced from 8 to 6 (1st reduction), from 6 to 3 (2nd reduction) and from 3 to 0 cmH2O (3rd reduction). 4. Partial arterial oxygen pressure (PaO2, mmHg) at 5 min and 120 min after LSF administration and during the 2nd PEEP reduction (PaO2(PEEP23/3)) were used for statistical comparison. All LSF preparations caused a dose-dependent increase for the PaO2(120'), whereas during the 2nd PEEP reduction only bovine and recombinant LSF exhibited dose-dependency. Exosurf did not increase PaO2 after administration of the highest dose. At the highest dose Exosurf exerted no further improvement but rather a tendency to relapse.(ABSTRACT TRUNCATED AT 250 WORDS) Images Figure 2 Figure 3 Figure 4 PMID:7582456

  5. Comparison of exogenous surfactant therapy, mechanical ventilation with high end-expiratory pressure and partial liquid ventilation in a model of acute lung injury.

    PubMed

    Hartog, A; Vazquez de Anda, G F; Gommers, D; Kaisers, U; Verbrugge, S J; Schnabel, R; Lachmann, B

    1999-01-01

    We have compared three treatment strategies, that aim to prevent repetitive alveolar collapse, for their effect on gas exchange, lung mechanics, lung injury, protein transfer into the alveoli and surfactant system, in a model of acute lung injury. In adult rats, the lungs were ventilated mechanically with 100% oxygen and a PEEP of 6 cm H2O, and acute lung injury was induced by repeated lung lavage to obtain a PaO2 value < 13 kPa. Animals were then allocated randomly (n = 12 in each group) to receive exogenous surfactant therapy, ventilation with high PEEP (18 cm H2O), partial liquid ventilation or ventilation with low PEEP (8 cm H2O) (ventilated controls). Blood-gas values were measured hourly. At the end of the 4-h study, in six animals per group, pressure-volume curves were constructed and bronchoalveolar lavage (BAL) was performed, whereas in the remaining animals lung injury was assessed. In the ventilated control group, arterial oxygenation did not improve and protein concentration of BAL and conversion of active to non-active surfactant components increased significantly. In the three treatment groups, PaO2 increased rapidly to > 50 kPa and remained stable over the next 4 h. The protein concentration of BAL fluid increased significantly only in the partial liquid ventilation group. Conversion of active to non-active surfactant components increased significantly in the partial liquid ventilation group and in the group ventilated with high PEEP. In the surfactant group and partial liquid ventilation groups, less lung injury was found compared with the ventilated control group and the group ventilated with high PEEP. We conclude that although all three strategies improved PaO2 to > 50 kPa, the impact on protein transfer into the alveoli, surfactant system and lung injury differed markedly.

  6. Effect of different ventilatory strategies on local and systemic cytokine production in intact swine lungs in vivo.

    PubMed

    Myrianthefs, P; Boutzouka, E; Venetsanou, K; Papalois, A; Kouloukousa, M; Kittas, C; Baltopoulos, G

    2006-05-01

    The purpose of the study was to investigate the effect of different ventilatory strategies on local and systemic cytokine production in swine with intact lungs in vivo after 4 h of mechanical ventilation. Twenty-five swine were anesthetized and then randomized into five groups (n = 5): (1) low tidal volume zero PEEP (LVZP); (2) medium tidal volume zero PEEP (MVZP); (3) high tidal volume zero PEEP (HVZP); (4) low tidal volume PEEP (LVP); (4) high tidal volume PEEP (HVP). Respiratory rate was adjusted to maintain normocapnia and fraction of inspired oxygen (FiO2) was 1.0. TNF-alpha and IL-10 were measured in BALF and serum at baseline, 2 h, and 4 h of MV. One animal in LVZP (2 h) and two in HVP (3 h) group died before the end of the experiment. TNF-alpha level in BALF was significantly higher in LVZP and LVP at 4 h compared to baseline and the other groups. IL-10 level in BALF was significantly higher in LVP at 4h compared to baseline and the other groups. There was a statistically significant increase in serum TNF-alpha levels at 4 h in LVP group compared to baseline and the other groups at 4 h. There was statistically significant increase in serum IL-10 levels in HVZP and LVP groups at 2 and 4 h which was significantly higher compared to the other groups at 4 h. Our results show that a) low volume MV may induce local and systemic pro- and anti-inflammatory cytokine increase b) in the presence of pro-inflammatory cytokine response there is also an anti-inflammatory response in the same compartment (lungs, circulation). c) There maybe loss of alveolar-to-systemic cytokine compartmentalization.

  7. Cardio-Pulmonary Response to Shock.

    DTIC Science & Technology

    1979-12-01

    increased 0.6 L/min (p < .05). These results indicate that local surgical trauma can stimulate the pulmonary secretion of PGI 2 to levels that have been... pulmonary metabolic changes induced by PEEP and examines the influence of the latter on hemodynmics. Experiments were conducted in 25 isolated, temperature...arterial pressure (MAP) from 113 ± 17 to 100 ± 26 mm Hg (p < .01). PEEP yielded no change in C0 or MAP in Group III. Pulse, pulmonary arterial wedge

  8. Rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART): Study protocol for a randomized controlled trial

    PubMed Central

    2012-01-01

    Background Acute respiratory distress syndrome (ARDS) is associated with high in-hospital mortality. Alveolar recruitment followed by ventilation at optimal titrated PEEP may reduce ventilator-induced lung injury and improve oxygenation in patients with ARDS, but the effects on mortality and other clinical outcomes remain unknown. This article reports the rationale, study design, and analysis plan of the Alveolar Recruitment for ARDS Trial (ART). Methods/Design ART is a pragmatic, multicenter, randomized (concealed), controlled trial, which aims to determine if maximum stepwise alveolar recruitment associated with PEEP titration is able to increase 28-day survival in patients with ARDS compared to conventional treatment (ARDSNet strategy). We will enroll adult patients with ARDS of less than 72 h duration. The intervention group will receive an alveolar recruitment maneuver, with stepwise increases of PEEP achieving 45 cmH2O and peak pressure of 60 cmH2O, followed by ventilation with optimal PEEP titrated according to the static compliance of the respiratory system. In the control group, mechanical ventilation will follow a conventional protocol (ARDSNet). In both groups, we will use controlled volume mode with low tidal volumes (4 to 6 mL/kg of predicted body weight) and targeting plateau pressure ≤30 cmH2O. The primary outcome is 28-day survival, and the secondary outcomes are: length of ICU stay; length of hospital stay; pneumothorax requiring chest tube during first 7 days; barotrauma during first 7 days; mechanical ventilation-free days from days 1 to 28; ICU, in-hospital, and 6-month survival. ART is an event-guided trial planned to last until 520 events (deaths within 28 days) are observed. These events allow detection of a hazard ratio of 0.75, with 90% power and two-tailed type I error of 5%. All analysis will follow the intention-to-treat principle. Discussion If the ART strategy with maximum recruitment and PEEP titration improves 28-day survival, this

  9. T-piece resuscitators: how do they compare?

    PubMed

    Hinder, Murray; McEwan, Alistair; Drevhammer, Thomas; Donaldson, Snorri; Tracy, Mark Brian

    2018-05-04

    The T-piece resuscitator (TPR) has seen increased use as a primary resuscitation device with newborns. Traditional TPR design uses a high resistance expiratory valve to produce positive end expiratory pressure (PEEP) or continuous positive airway pressure (CPAP) at resuscitation. A new TPR device that uses a dual flow ratio valve (fluidic flip) to produce PEEP/CPAP is now available (rPAP). We aimed to compare the measured ventilation performance of different TPR devices in a controlled bench test study. Single operator provided positive pressure ventilation to an incremental testlung compliance (Crs) model (0.5-5 mL/cmH 2 O) with five different brands of TPR device (Atom, Neopuff, rPAP, GE Panda warmer and Draeger Resuscitaire). At recommended peak inflation pressure (PIP) 20 cmH 2 O, PEEP of 5 cmH 2 O and rate of 60 inflations per minute. 1864 inflations were analysed. Four of the five devices tested demonstrated inadvertent elevations in mean PEEP (5.5-10.3 cmH 2 O, p<0.001) from set value as Crs was increased, while one device (rPAP) remained at the set value. Measured PIP exceeded the set value in two infant warmer devices (GE and Draeger) with inbuilt TPR at Crs of 0.5 (24.5 and 23.5 cmH 2 O, p<0.001). Significant differences were seen in tidal volumes across devices particularly at higher Crs (p<0.001). Results show important variation in delivered ventilation from set values due to inherent TPR device design characteristics with a range of lung compliances expected at birth. Device-generated inadvertent PEEP and overdelivery of PIP may be clinically deleterious for term and preterm newborns or infants with larger Crs during resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Exploring for the safer ventilation method in laparoscopic urologic patients? Conventional or low tidal?

    PubMed

    Ela, Yüksel; Bakı, Elif Doğan; Ateş, Mutlu; Kokulu, Serdar; Keleş, İbrahim; Karalar, Mustafa; Şenay, Hasan; Sıvacı, Remziye Gül

    2014-11-01

    To study the effects of low tidal volume with positive end-expiratory pressure (PEEP) on arterial blood gases of patients undergoing laparoscopic urologic surgeries. Eighty-six laparoscopic urologic patients were enrolled in this study. Patients were randomized into two groups according to the ventilatory settings. In the conventional group (Group C) (n=43), the tidal volume was 10 mL/kg, and the PEEP was set at 0 cm of H2O. In the low tidal volume with PEEP group (Group LP), the tidal volume was 6 mL/kg, with PEEP of 5 cm of H2O. In both groups total minute volume was 6 L/kg. Peak and plateau airway pressure (PPEAK and PPLAT, respectively) and arterial blood gases were recorded before pneumoperitoneum (PNP) (T1) and the first and third hour (T3) after PNP induction and also after extubation in the intensive care unit. Additionally, heart rate, mean arterial pressure, and peripheral O2 saturation of hemoglobin were recorded. Heart rate, PPEAK, and PPLAT values were similar in both groups. Partial arterial O2 pressure values measured postoperatively were significantly higher in Group LP, whereas those measured before PNP induction were similar (P=.014 and P=.056, respectively). Compared with the baseline, partial arterial CO2 pressure values measured at T1 and at T3 after PNP induction were significantly higher in Group C than in Group LP (P<.001). The pH values of Group C at T1 and at T3 postoperatively were significantly lower than the values of Group LP (P<.001). Extubation times were significantly lower in Group LP. The results of the present study suggest that low tidal volume with PEEP application may be a good alternative for preventing high CO2 levels and yielding better oxygenation and lower extubation times in patients undergoing prolonged laparoscopic urology.

  11. Physiologic effects of alveolar recruitment and inspiratory pauses during moderately-high-frequency ventilation delivered by a conventional ventilator in a severe lung injury model

    PubMed Central

    Costa, Eduardo Leite Vieira; Azevedo, Luciano Cesar Pontes; Gomes, Susimeire; Amato, Marcelo Britto Passos; Park, Marcelo

    2017-01-01

    Background and aims To investigate whether performing alveolar recruitment or adding inspiratory pauses could promote physiologic benefits (VT) during moderately-high-frequency positive pressure ventilation (MHFPPV) delivered by a conventional ventilator in a porcine model of severe acute respiratory distress syndrome (ARDS). Methods Prospective experimental laboratory study with eight pigs. Induction of acute lung injury with sequential pulmonary lavages and injurious ventilation was initially performed. Then, animals were ventilated on a conventional mechanical ventilator with a respiratory rate (RR) = 60 breaths/minute and PEEP titrated according to ARDS Network table. The first two steps consisted of a randomized order of inspiratory pauses of 10 and 30% of inspiratory time. In final step, we removed the inspiratory pause and titrated PEEP, after lung recruitment, with the aid of electrical impedance tomography. At each step, PaCO2 was allowed to stabilize between 57–63 mmHg for 30 minutes. Results The step with RR of 60 after lung recruitment had the highest PEEP when compared with all other steps (17 [16,19] vs 14 [10, 17]cmH2O), but had lower driving pressures (13 [13,11] vs 16 [14, 17]cmH2O), higher P/F ratios (212 [191,243] vs 141 [105, 184] mmHg), lower shunt (23 [20, 23] vs 32 [27, 49]%), lower dead space ventilation (10 [0, 15] vs 30 [20, 37]%), and a more homogeneous alveolar ventilation distribution. There were no detrimental effects in terms of lung mechanics, hemodynamics, or gas exchange. Neither the addition of inspiratory pauses or the alveolar recruitment maneuver followed by decremental PEEP titration resulted in further reductions in VT. Conclusions During MHFPPV set with RR of 60 bpm delivered by a conventional ventilator in severe ARDS swine model, neither the inspiratory pauses or PEEP titration after recruitment maneuver allowed reduction of VT significantly, however the last strategy decreased driving pressures and improved both shunt

  12. Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter.

    PubMed

    Gölcük, Adem; Işık, Hakan; Güler, İnan

    2016-07-01

    This study aims to introduce a novel device with which mechanical ventilator and pulse oximeter work in synchronization. Serial communication technique was used to enable communication between the pulse oximeter and the ventilator. The SpO2 value and the pulse rate read on the pulse oximeter were transmitted to the mechanical ventilator through transmitter (Tx) and receiver (Rx) lines. The fuzzy-logic-based software developed for the mechanical ventilator interprets these values and calculates the percentage of oxygen (FiO2) and Positive End-Expiratory Pressure (PEEP) to be delivered to the patient. The fuzzy-logic-based software was developed to check the changing medical states of patients and to produce new results (FiO2 ve PEEP) according to each new state. FiO2 and PEEP values delivered from the ventilator to the patient can be calculated in this way without requiring any arterial blood gas analysis. Our experiments and the feedbacks from physicians show that this device makes it possible to obtain more successful results when compared to the current practices.

  13. High tidal volume ventilation in infant mice.

    PubMed

    Cannizzaro, Vincenzo; Zosky, Graeme R; Hantos, Zoltán; Turner, Debra J; Sly, Peter D

    2008-06-30

    Infant mice were ventilated with either high tidal volume (V(T)) with zero end-expiratory pressure (HVZ), high V(T) with positive end-expiratory pressure (PEEP) (HVP), or low V(T) with PEEP. Thoracic gas volume (TGV) was determined plethysmographically and low-frequency forced oscillations were used to measure the input impedance of the respiratory system. Inflammatory cells, total protein, and cytokines in bronchoalveolar lavage fluid (BALF) and interleukin-6 (IL-6) in serum were measured as markers of pulmonary and systemic inflammatory response, respectively. Coefficients of tissue damping and tissue elastance increased in all ventilated mice, with the largest rise seen in the HVZ group where TGV rapidly decreased. BALF protein levels increased in the HVP group, whereas serum IL-6 rose in the HVZ group. PEEP keeps the lungs open, but provides high volumes to the entire lungs and induces lung injury. Compared to studies in adult and non-neonatal rodents, infant mice demonstrate a different response to similar ventilation strategies underscoring the need for age-specific animal models.

  14. Mortality and pulmonary mechanics in relation to respiratory system and transpulmonary driving pressures in ARDS.

    PubMed

    Baedorf Kassis, Elias; Loring, Stephen H; Talmor, Daniel

    2016-08-01

    The driving pressure of the respiratory system has been shown to strongly correlate with mortality in a recent large retrospective ARDSnet study. Respiratory system driving pressure [plateau pressure-positive end-expiratory pressure (PEEP)] does not account for variable chest wall compliance. Esophageal manometry can be utilized to determine transpulmonary driving pressure. We have examined the relationships between respiratory system and transpulmonary driving pressure, pulmonary mechanics and 28-day mortality. Fifty-six patients from a previous study were analyzed to compare PEEP titration to maintain positive transpulmonary end-expiratory pressure to a control protocol. Respiratory system and transpulmonary driving pressures and pulmonary mechanics were examined at baseline, 5 min and 24 h. Analysis of variance and linear regression were used to compare 28 day survivors versus non-survivors and the intervention group versus the control group, respectively. At baseline and 5 min there was no difference in respiratory system or transpulmonary driving pressure. By 24 h, survivors had lower respiratory system and transpulmonary driving pressures. Similarly, by 24 h the intervention group had lower transpulmonary driving pressure. This decrease was explained by improved elastance and increased PEEP. The results suggest that utilizing PEEP titration to target positive transpulmonary pressure via esophageal manometry causes both improved elastance and driving pressures. Treatment strategies leading to decreased respiratory system and transpulmonary driving pressure at 24 h may be associated with improved 28 day mortality. Studies to clarify the role of respiratory system and transpulmonary driving pressures as a prognosticator and bedside ventilator target are warranted.

  15. Continuous on-line measurements of respiratory system, lung and chest wall mechanics during mechanic ventilation.

    PubMed

    Kárason, S; Søndergaard, S; Lundin, S; Stenqvist, O

    2001-08-01

    We present a concept of on-line, manoeuvre-free monitoring of respiratory mechanics during dynamic conditions, displaying calculated alveolar pressure/volume curves continuously and separating lung and chest wall mechanics. Prospective observational study. Intensive care unit of a university hospital. Ten ventilator-treated patients with acute lung injury. Different positive end-expiratory pressure (PEEP) and tidal volumes, low flow inflation. Previously validated methods were used to present a single-value dynostatic compliance for the whole breath and a dynostatic volume-dependent initial, middle and final compliance within the breath. A high individual variation of respiratory mechanics was observed. Reproducibility of repeated measurements was satisfactory (coefficients of variations for dynostatic volume-dependent compliance: < or =9.2% for total respiratory system, < or =18% for lung). Volume-dependent compliance showed a statistically significant pattern of successively decreasing compliance from the initial segment through the middle and final parts within each breath at all respiratory settings. This pattern became more prominent with increasing PEEP and tidal volume, indicating a greater distension of alveoli. No lower inflection point (LIP) was seen in patients with respiratory rate 20/min and PEEP at 4 cmH2O. A trial with low flow inflation in four of the patients showed formation of a LIP in three of them and an upper inflection in one. The monitoring concept revealed a constant pattern of successively decreasing compliance within each breath, which became more prominent with increasing PEEP and tidal volume. The monitoring concept offers a simple and reliable method of monitoring respiratory mechanics during ongoing ventilator treatment.

  16. Postural lung recruitment assessed by lung ultrasound in mechanically ventilated children.

    PubMed

    Tusman, Gerardo; Acosta, Cecilia M; Böhm, Stephan H; Waldmann, Andreas D; Ferrando, Carlos; Marquez, Manuel Perez; Sipmann, Fernando Suarez

    2017-10-13

    Atelectasis is a common finding in mechanically ventilated children with healthy lungs. This lung collapse cannot be overcome using standard levels of positive end-expiratory pressure (PEEP) and thus for only individualized lung recruitment maneuvers lead to satisfactory therapeutic results. In this short communication, we demonstrate by lung ultrasound images (LUS) the effect of a postural recruitment maneuver (P-RM, i.e., a ventilatory strategy aimed at reaerating atelectasis by changing body position under constant ventilation). Data was collected in the operating room of the Hospital Privado de Comunidad, Mar del Plata, Argentina. Three anesthetized children undergoing mechanical ventilation at constant settings were sequentially subjected to the following two maneuvers: (1) PEEP trial in the supine position PEEP was increased to 10 cmH 2 O for 3 min and then decreased to back to baseline. (2) P-RM patient position was changed from supine to the left and then to the right lateral position for 90 s each before returning to supine. The total P-RM procedure took approximately 3 min. LUS in the supine position showed similar atelectasis before and after the PEEP trial. Contrarily, atelectasis disappeared in the non-dependent lung when patients were placed in the lateral positions. Both lungs remained atelectasis free even after returning to the supine position. We provide LUS images that illustrate the concept and effects of postural recruitment in children. This maneuver has the advantage of achieving recruitment effects without the need to elevate airways pressures.

  17. Effects of a preemptive alveolar recruitment strategy on arterial oxygenation during one-lung ventilation with different tidal volumes in patients with normal pulmonary function test.

    PubMed

    Jung, Jong Dal; Kim, Sang Hun; Yu, Byung Sik; Kim, Hye Ji

    2014-08-01

    Hypoxemia during one-lung ventilation (OLV) remains a major concern. The present study compared the effect of alveolar recruitment strategy (ARS) on arterial oxygenation during OLV at varying tidal volumes (Vt) with or without positive end-expiratory pressure (PEEP). In total, 120 patients undergoing wedge resection by video assisted thoracostomy were randomized into four groups comprising 30 patients each: those administered a 10 ml/kg tidal volume with or without preemptive ARS (Group H and Group H-ARS, respectively) and those administered a 6 ml/kg tidal volume and a 8 cmH2O PEEP with or without preemptive ARS (Group L and Group L-ARS, respectively). ARS was performed using pressure-controlled ventilation with a 40 cmH2O plateau airway pressure and a 15 cmH2O PEEP for at least 10 breaths until OLV began. Preemptive ARS significantly improved the PaO2/FiO2 ratio compared to the groups that did not receive ARS (P < 0.05). The H-ARS group showed a highest PaO2/FiO2 ratio during OLV, the L-ARS and H groups showed similarly improved arterial oxygenation, which was significantly higher than in group L (P < 0.05). The plateau airway pressure in group H-ARS was significantly higher than in group L-ARS (P < 0.05). Preemptive ARS can improve arterial oxygenation during OLV. Furthermore, a 6 ml/kg tidal volume combined with 8 cmH2O PEEP after preemptive ARS may reduce the risk of pulmonary injury caused by high tidal volume during one-lung ventilation in patients with normal pulmonary function.

  18. Apparent diffusion coefficient of hyperpolarized (3)He with minimal influence of the residual gas in small animals.

    PubMed

    Carrero-González, L; Kaulisch, T; Ruiz-Cabello, J; Pérez-Sánchez, J M; Peces-Barba, G; Stiller, D; Rodríguez, I

    2012-09-01

    The apparent diffusion coefficient (ADC) of hyperpolarized (HP) gases is a parameter that reflects changes in lung microstructure. However, ADC is dependent on many physiological and experimental variables that need to be controlled or specified in order to ensure the reliability and reproducibility of this parameter. A single breath-hold experiment is desirable in order to reduce the amount of consumed HP gas. The application of a positive end-expiratory pressure (PEEP) causes an increase in the residual gas volume. Depending on the applied PEEP, the ratio between the incoming and residual gas volumes will change and the ADC will vary, as long as both gases do not have the same diffusion coefficient. The most standard method for human applications uses air for breathing and a bolus of pure HP (3)He for MRI data acquisition. By applying this method in rats, we have demonstrated that ADC values are strongly dependent on the applied PEEP, and therefore on the residual gas volume in the lung. This outcome will play an important role in studies concerning certain diseases, such as emphysema, which is characterized by an increase in the residual volume. Ventilation with an oxygen-helium mixture (VOHeM) is a proposed single breath-hold method that uses two different gas mixtures (O(2)-(4)He for ventilation and HP (3)He-N(2) for imaging). The concentration of each gas in its respective mixture was calculated in order to obtain the same diffusion coefficient in both mixtures. ADCs obtained from VOHeM are independent of PEEP, thus minimizing the effect of the different residual volumes. Copyright © 2012 John Wiley & Sons, Ltd.

  19. Intraoperative low tidal volume ventilation strategy has no benefits during laparoscopic cholecystectomy

    PubMed Central

    Arora, Vandna; Tyagi, Asha; Kumar, Surendra; Kakkar, Aanchal; Das, Shukla

    2017-01-01

    Background and Aims: Benefits of intraoperative low tidal volume ventilation during laparoscopic surgery are not conclusively proven, even though its advantages were seen in other situations with intraoperative respiratory compromise such as one-lung ventilation. The present study compared the efficacy of intraoperative low tidal volume ventilatory strategy (6 ml/kg along with positive end-expiratory pressure [PEEP] of 10 cmH2O) versus one with higher tidal volume (10 ml/kg with no PEEP) on various clinical parameters and plasma levels of interleukin (IL)-6 in patients undergoing laparoscopic cholecystectomy. Material and Methods: A total of 58 adult patients with American Society of Anesthesiologists physical status I or II, undergoing laparoscopic cholecystectomy were randomized to receive the low or higher tidal volume strategy as above (n = 29 each). The primary outcome measure was postoperative PaO2. Systemic levels of IL-6 along with clinical indices of intraoperative gas exchange, pulmonary mechanics, and hemodynamic consequences were measured as secondary outcome measures. Results: There was no statistically significant difference in oxygenation; intraoperative dynamic compliance, peak airway pressures, or hemodynamic parameters, or the IL-6 levels between the two groups (P > 0.05). Low tidal volume strategy was associated with significantly higher mean airway pressure, lower airway resistance, greater respiratory rates, and albeit clinically similar, higher PaCO2and lower pH (P < 0.05). Conclusion: Strategy using 6 ml/kg tidal volume along with 10 cmH2O of PEEP was not associated with any significant improvement in gas exchange, hemodynamic parameters, or systemic inflammatory response over ventilation with 10 ml/kg volume without PEEP during laparoscopic cholecystectomy. PMID:28413273

  20. Hemodynamic effects of external continuous negative pressure ventilation compared with those of continuous positive pressure ventilation in dogs with acute lung injury.

    PubMed

    Skaburskis, M; Helal, R; Zidulka, A

    1987-10-01

    Patients with noncardiogenic pulmonary edema requiring ventilatory assistance are usually supported with CPPV using positive end-expiratory pressure (PEEP), but CPPV requires endotracheal intubation and may decrease cardiac output (QT). The purpose of this study was to examine thoracoabdominal continuous negative pressure ventilation (CNPV) using external negative end-expiratory pressure (NEEP). The effects on gas exchange and hemodynamics were compared with those of CPPV with PEEP, with the premise that CNPV might sustain venous return and improve QT. In 6 supine, anesthetized and paralyzed dogs with oleic-acid-induced pulmonary edema, 30 min of CNPV was alternated twice with 30 min of CPPV. Positive and negative pressure ventilation were carefully matched for fractional inspired oxygen concentration (FIO2 = 0.56), breathing frequency, and tidal volume. In addition, we matched the increase in delta FRC obtained with the constant distending pressures produced by both modes of ventilation. An average of -9 cm H2O of NEEP produced the same delta FRC as 10.8 cm H2O of PEEP. Gas exchange did not differ significantly between the 2 modes. However, QT was 15.8% higher during CNPV than during CPPV (p less than 0.02). Mixed venous oxygen saturation also improved during CNPV compared with that during CPPV (58.3 versus 54.5%, p less than 0.01). Negative pressure ventilation using NEEP may be a viable alternative to positive pressure ventilation with PEEP in the management of critically ill patients with noncardiogenic pulmonary edema. It offers comparable improvement in gas exchange with the advantages of less cardiac depression and the possible avoidance of endotracheal intubation.

  1. High Positive End-Expiratory Pressure Renders Spontaneous Effort Noninjurious.

    PubMed

    Morais, Caio C A; Koyama, Yukiko; Yoshida, Takeshi; Plens, Glauco M; Gomes, Susimeire; Lima, Cristhiano A S; Ramos, Ozires P S; Pereira, Sérgio M; Kawaguchi, Naomasa; Yamamoto, Hirofumi; Uchiyama, Akinori; Borges, João B; Vidal Melo, Marcos F; Tucci, Mauro R; Amato, Marcelo B P; Kavanagh, Brian P; Costa, Eduardo L V; Fujino, Yuji

    2018-05-15

    In acute respiratory distress syndrome (ARDS), atelectatic solid-like lung tissue impairs transmission of negative swings in pleural pressure (Ppl) that result from diaphragmatic contraction. The localization of more negative Ppl proportionally increases dependent lung stretch by drawing gas either from other lung regions (e.g., nondependent lung [pendelluft]) or from the ventilator. Lowering the level of spontaneous effort and/or converting solid-like to fluid-like lung might render spontaneous effort noninjurious. To determine whether spontaneous effort increases dependent lung injury, and whether such injury would be reduced by recruiting atelectatic solid-like lung with positive end-expiratory pressure (PEEP). Established models of severe ARDS (rabbit, pig) were used. Regional histology (rabbit), inflammation (positron emission tomography; pig), regional inspiratory Ppl (intrabronchial balloon manometry), and stretch (electrical impedance tomography; pig) were measured. Respiratory drive was evaluated in 11 patients with ARDS. Although injury during muscle paralysis was predominantly in nondependent and middle lung regions at low (vs. high) PEEP, strong inspiratory effort increased injury (indicated by positron emission tomography and histology) in dependent lung. Stronger effort (vs. muscle paralysis) caused local overstretch and greater tidal recruitment in dependent lung, where more negative Ppl was localized and greater stretch was generated. In contrast, high PEEP minimized lung injury by more uniformly distributing negative Ppl, and lowering the magnitude of spontaneous effort (i.e., deflection in esophageal pressure observed in rabbits, pigs, and patients). Strong effort increased dependent lung injury, where higher local lung stress and stretch was generated; effort-dependent lung injury was minimized by high PEEP in severe ARDS, which may offset need for paralysis.

  2. Changes of air-tissue ratio evaluated by EBCT after cardiopulmonary resuscitation (CPR): validation in swine

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Schuster, Antonius H.; Kleinsasser, Axel; Loeckinger, Alexander; Hoermann, Christoph; zur Nedden, Dieter

    2001-05-01

    The purpose was to evaluate changes of the air-tissue ratio (ATR) in previously defined regions of interest after cardiopulmonary resuscitation (CPR) in porcine model. Eight anesthetized and ventilated pigs we scanned in supine position before and 30 minutes after CPR at two different constant PEEP levels (5 cm H2O, 15 cm H2O). Volume scans were obtained using 6 mm slices. The gray values of the lung were divided into steps of 100 HU in order to get access to the changes of ATR. ATR was evaluated in ventral, intermediate and dorsal regions of the lung. CPR for 9 minutes led to an uneven distribution of ventilation. In the ventral region, areas with high ATR increased. Areas with normal ATR decreased. In contrast the dorsal regions with low ATR increased. ATR in the intermediate regions remained almost unchanged. Using the higher PEEP level, areas with normal ATR showed a marked increase accompanied by a decrease of areas with low ATR. After CPR, an uneven distribution of lung aeration was detected. According to the impaired hemodynamics, areas with normal ATR decreased and areas with high and low ATR increased. Using higher PEEP levels improved lung aeration.

  3. Of gossips, eavesdroppers, and peeping toms

    PubMed Central

    Francis, Huw W S

    1982-01-01

    British accounts of medical ethics concentrate on confidentiality to the exclusion of wider questions of privacy. This paper argues for consideration of privacy within medical ethics, and illustrates through the television series `Hospital', what may go awry when this wider concept is forgotten. PMID:7131499

  4. A ventilation strategy during general anaesthesia to reduce postoperative atelectasis.

    PubMed

    Edmark, Lennart; Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats

    2014-08-01

    Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. The median area of atelectasis was 5.2 cm(2) (range 1.6-12.2 cm(2)) and 8.5 cm(2) (3-23.1 cm(2)) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm(2)) was statistically significant (confidence interval 0.2-7.6 cm(2), p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm(2) (1.8-14.7 cm(2)). Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers.

  5. A ventilation strategy during general anaesthesia to reduce postoperative atelectasis

    PubMed Central

    Auner, Udo; Hallén, Jan; Lassinantti-Olowsson, Lena; Hedenstierna, Göran; Enlund, Mats

    2014-01-01

    Background Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy, without recruitment manoeuvres, using a combination of continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and a reduced end-expiratory oxygen fraction (FETO2) before ending mask ventilation with CPAP after extubation would reduce the area of postoperative atelectasis. Methods Thirty patients were randomized into three groups. During induction and emergence, inspiratory oxygen fractions (FIO2) were 1.0 in the control group and 1.0 or 0.8 in the intervention groups. No CPAP/PEEP was used in the control group, whereas CPAP/PEEP of 6 cmH2O was used in the intervention groups. After extubation, FIO2 was set to 0.30 in the intervention groups and CPAP was applied, aiming at FETO2 < 0.30. Atelectasis was studied by computed tomography 25 min postoperatively. Results The median area of atelectasis was 5.2 cm2 (range 1.6–12.2 cm2) and 8.5 cm2 (3–23.1 cm2) in the groups given FIO2 1.0 with or without CPAP/PEEP, respectively. After correction for body mass index the difference between medians (2.9 cm2) was statistically significant (confidence interval 0.2–7.6 cm2, p = 0.04). In the group given FIO2 0.8, in which seven patients were ex- or current smokers, the median area of atelectasis was 8.2 cm2 (1.8–14.7 cm2). Conclusion Compared with conventional ventilation, after correction for obesity, this ventilation strategy reduced the area of postoperative atelectasis in one of the intervention groups but not in the other group, which included a higher proportion of smokers. PMID:24758245

  6. Mitogen-activated protein kinase phosphatase-1 modulates regional effects of injurious mechanical ventilation in rodent lungs.

    PubMed

    Park, Moo Suk; He, Qianbin; Edwards, Michael G; Sergew, Amen; Riches, David W H; Albert, Richard K; Douglas, Ivor S

    2012-07-01

    Mechanical ventilation induces heterogeneous lung injury by mitogen-activated protein kinase (MAPK) and nuclear factor-κB. Mechanisms regulating regional injury and protective effects of prone positioning are unclear. To determine the key regulators of the lung regional protective effects of prone positioning in rodent lungs exposed to injurious ventilation. Adult rats were ventilated with high (18 ml/kg, positive end-expiratory pressure [PEEP] 0) or low Vt (6 ml/kg; PEEP 3 cm H(2)O; 3 h) in supine or prone position. Dorsal-caudal lung mRNA was analyzed by microarray and MAPK phosphatases (MKP)-1 quantitative polymerase chain reaction. MKP-1(-/-) or wild-type mice were ventilated with very high (24 ml/kg; PEEP 0) or low Vt (6-7 ml/kg; PEEP 3 cm H(2)O). The MKP-1 regulator PG490-88 (MRx-108; 0.75 mg/kg) or phosphate-buffered saline was administered preventilation. Injury was assessed by lung mechanics, bronchioalveolar lavage cell counts, protein content, and lung injury scoring. Immunoblotting for MKP-1, and IκBα and cytokine ELISAs were performed on lung lysates. Prone positioning was protective against injurious ventilation in rats. Expression profiling demonstrated MKP-1 20-fold higher in rats ventilated prone rather than supine and regional reduction in p38 and c-jun N-terminal kinase activation. MKP-1(-/-) mice experienced amplified injury. PG490-88 improved static lung compliance and injury scores, reduced bronchioalveolar lavage cell counts and cytokine levels, and induced MKP-1 and IκBα. Injurious ventilation induces MAPK in an MKP-1-dependent fashion. Prone positioning is protective and induces MKP-1. PG490-88 induced MKP-1 and was protective against high Vt in a nuclear factor-κB-dependent manner. MKP-1 is a potential target for modulating regional effects of injurious ventilation.

  7. Protective ventilation in experimental acute respiratory distress syndrome after ventilator-induced lung injury: a randomized controlled trial.

    PubMed

    Uttman, L; Bitzén, U; De Robertis, E; Enoksson, J; Johansson, L; Jonson, B

    2012-10-01

    Low tidal volume (V(T)), PEEP, and low plateau pressure (P(PLAT)) are lung protective during acute respiratory distress syndrome (ARDS). This study tested the hypothesis that the aspiration of dead space (ASPIDS) together with computer simulation can help maintain gas exchange at these settings, thus promoting protection of the lungs. ARDS was induced in pigs using surfactant perturbation plus an injurious ventilation strategy. One group then underwent 24 h protective ventilation, while control groups were ventilated using a conventional ventilation strategy at either high or low pressure. Pressure-volume curves (P(el)/V), blood gases, and haemodynamics were studied at 0, 4, 8, 16, and 24 h after the induction of ARDS and lung histology was evaluated. The P(el)/V curves showed improvements in the protective strategy group and deterioration in both control groups. In the protective group, when respiratory rate (RR) was ≈ 60 bpm, better oxygenation and reduced shunt were found. Histological damage was significantly more severe in the high-pressure group. There were no differences in venous oxygen saturation and pulmonary vascular resistance between the groups. The protective ventilation strategy of adequate pH or PaCO2 with minimal V(T), and high/safe P(PLAT) resulting in high PEEP was based on the avoidance of known lung-damaging phenomena. The approach is based upon the optimization of V(T), RR, PEEP, I/E, and dead space. This study does not lend itself to conclusions about the independent role of each of these features. However, dead space reduction is fundamental for achieving minimal V(T) at high RR. Classical physiology is applicable at high RR. Computer simulation optimizes ventilation and limiting of dead space using ASPIDS. Inspiratory P(el)/V curves recorded from PEEP or, even better, expiratory P(el)/V curves allow monitoring in ARDS.

  8. Integrating partner professionals. The Early Explorers project: Peers Early Education Partnership and the health visiting service.

    PubMed

    Barlow, J; Coe, C

    2013-01-01

      A range of voluntary sector organizations are involved in the delivery of services to children, particularly within the Early Year's sector and children's centres. Peers Early Education Partnership (PEEP) Early Explorers project is one example of the way in which explicit partnerships are being forged across statutory and voluntary sectors with the aim of improving outcomes for children and families. This paper reports an exploration of stakeholder views and experiences of two Early Explorer clinics located in areas of high deprivation.   Semi-structured interviews were conducted with a purposive sample of stakeholders (n= 25) from children's centres, PEEP, the health visiting service and service users. Data were fully transcribed and analysed using a thematic approach.   The data suggest that the two key groups of stakeholders providing Early Explorer clinics (i.e. health visitors and PEEP practitioners) had quite different objectives in terms of their early goals for the clinic, but that despite these differences good progress was achieved in terms of working together effectively. All stakeholders including service users referred to the presence of PEEP as having improved the quality of the clinic environment, and participating mothers identified a wide range of benefits from the enhanced service. However, somewhat restricted views about the role of practitioners within the clinics were identified by users, and the findings suggest that although the early goals for the clinic had been exceeded, these may have been limited in terms of true 'partnership' working.   Early Explorer clinics appeared to have enhanced the service provided within traditional child health clinics and to have provided practitioners with access to hard-to-reach families and parents with access to services that are consistent with the broader policy aims of improving parent-infant interaction. However, questions remain as to whether the benefit of 'partnership' working was fully

  9. Multifaceted bench comparative evaluation of latest intensive care unit ventilators.

    PubMed

    Garnier, M; Quesnel, C; Fulgencio, J-P; Degrain, M; Carteaux, G; Bonnet, F; Similowski, T; Demoule, A

    2015-07-01

    Independent bench studies using specific ventilation scenarios allow testing of the performance of ventilators in conditions similar to clinical settings. The aims of this study were to determine the accuracy of the latest generation ventilators to deliver chosen parameters in various typical conditions and to provide clinicians with a comprehensive report on their performance. Thirteen modern intensive care unit ventilators were evaluated on the ASL5000 test lung with and without leakage for: (i) accuracy to deliver exact tidal volume (VT) and PEEP in assist-control ventilation (ACV); (ii) performance of trigger and pressurization in pressure support ventilation (PSV); and (iii) quality of non-invasive ventilation algorithms. In ACV, only six ventilators delivered an accurate VT and nine an accurate PEEP. Eleven devices failed to compensate VT and four the PEEP in leakage conditions. Inspiratory delays differed significantly among ventilators in invasive PSV (range 75-149 ms, P=0.03) and non-invasive PSV (range 78-165 ms, P<0.001). The percentage of the ideal curve (concomitantly evaluating the pressurization speed and the levels of pressure reached) also differed significantly (range 57-86% for invasive PSV, P=0.04; and 60-90% for non-invasive PSV, P<0.001). Non-invasive ventilation algorithms efficiently prevented the decrease in pressurization capacities and PEEP levels induced by leaks in, respectively, 10 and 12 out of the 13 ventilators. We observed real heterogeneity of performance amongst the latest generation of intensive care unit ventilators. Although non-invasive ventilation algorithms appear to maintain adequate pressurization efficiently in the case of leakage, basic functions, such as delivered VT in ACV and pressurization in PSV, are often less reliable than the values displayed by the device suggest. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions

  10. [Lung protective ventilation. Ventilatory modes and ventilator parameters].

    PubMed

    Schädler, Dirk; Weiler, Norbert

    2008-06-01

    Mechanical ventilation has a considerable potential for injuring the lung tissue. Therefore, attention has to be paid to the proper choice of ventilatory mode and settings to secure lung-protective ventilation whenever possible. Such ventilator strategy should account for low tidal volume ventilation (6 ml/kg PBW), limited plateau pressure (30 to 35 cm H2O) and positive end-expiratory pressure (PEEP). It is unclear whether pressure controlled or volume controlled ventilation with square flow profile is beneficial. The adjustment of inspiration and expiration time should consider the actual breathing mechanics and anticipate the generation of intrinsic PEEP. Ventilatory modes with the possibility of supporting spontaneous breathing should be used as soon as possible.

  11. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery.

    PubMed

    Hemmes, Sabrine N T; Severgnini, Paolo; Jaber, Samir; Canet, Jaume; Wrigge, Hermann; Hiesmayr, Michael; Tschernko, Edda M; Hollmann, Markus W; Binnekade, Jan M; Hedenstierna, Göran; Putensen, Christian; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2011-05-06

    Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP) and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery. The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO") trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH(2)O with recruitment maneuvers (the lung-protective strategy) or mechanical ventilation with the level of PEEP at maximum 2 cmH(2)O without recruitment maneuvers (the conventional strategy). The primary endpoint is any post-operative pulmonary complication. The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications. ISRCTN: ISRCTN70332574.

  12. Lung-protective ventilation in abdominal surgery.

    PubMed

    Futier, Emmanuel; Jaber, Samir

    2014-08-01

    To provide the most recent and relevant clinical evidence regarding the use of prophylactic lung-protective mechanical ventilation in abdominal surgery. Evidence is accumulating, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary complications in patients undergoing abdominal surgery. Nonprotective ventilator settings, especially high tidal volume (>10-12 ml/kg), very low level of positive end-expiratory pressure (PEEP, <5 cm H2O), or no PEEP, may cause alveolar overdistension and repetitive tidal recruitment leading to ventilator-associated lung injury in patients with healthy lungs. Stimulated by the previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung-protective mechanical ventilation. Recent data provide compelling evidence that prophylactic lung-protective mechanical ventilation using lower tidal volume (6-8 ml/kg of predicted body weight), moderate PEEP (6-8 cm H2O), and recruitment maneuvers is associated with improved functional or physiological and clinical postoperative outcome in patients undergoing abdominal surgery. The use of prophylactic lung-protective ventilation can help in improving the postoperative outcome.

  13. Respirator triggering of electron beam computed tomography (EBCT): evaluation of dynamic changes during mechanical expiration in the traumatized patient

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Kleinsasser, Axel; Hatschenberger, Robert; Knapp, Rudolf; zur Nedden, Dieter; Hoermann, Christoph

    1999-05-01

    The purpose of this project is to evaluate the dynamic changes during expiration at different levels of positive end- expiratory pressure (PEEP) in the ventilated patient. We wanted to discriminate between normal lung function and acute respiratory distress syndrome (ARDS). After approval by the local Ethic Committee we studied two ventilated patients: (1) with normal lung function; (2) ARDS). We used the 50 ms scan mode of the EBCT. The beam was positioned 1 cm above the diaphragm. The table position remained unchanged. An electronic trigger was developed, that utilizes the respirators synchronizing signal to start the EBCT at the onset of expiration. During controlled mechanical expiration at two levels of PEEP (0 and 15 cm H2O), pulmonary aeration was rated as: well-aerated (-900HU/-500HU), poorly- aerated (-500HU/-100HU) and non-aerated (-100HU/+100HU). Pathological and normal lung function showed different dynamic changes (FIG.4-12). The different PEEP levels resulted in a significant change of pulmonary aeration in the same patient. Although we studied only a very limited number of patients, respirator triggered EBCT may be accurate in discriminating pathological changes due to the abnormal lung function in the mechanically ventilated patient.

  14. Risk Factors for the Mortality of Pneumocystis jirovecii Pneumonia in Non-HIV Patients Who Required Mechanical Ventilation: A Retrospective Case Series Study.

    PubMed

    Kotani, Toru; Katayama, Shinshu; Miyazaki, Yuya; Fukuda, Satoshi; Sato, Yoko; Ohsugi, Koichi

    2017-01-01

    The risk factors for the mortality rate of Pneumocystis jirovecii pneumonia (PCP) who required mechanical ventilation (MV) remained unknown. A retrospective chart review was performed of all PCP patients admitted to our intensive care unit and treated for acute hypoxemic respiratory failure to assess the risk factors for the high mortality. Twenty patients without human immunodeficiency virus infection required mechanical ventilation; 19 received noninvasive ventilation; and 11 were intubated. PEEP was incrementally increased and titrated to maintain FIO 2 as low as possible. No mandatory ventilation was used. Sixteen patients (80%) survived. Pneumothorax developed in one patient with rheumatoid arthritis (RA). Median PEEP level in the first 5 days was 10.0 cmH 2 O and not associated with death. Multivariate analysis showed the association of incidence of interstitial lung disease and increase in serum KL-6 with 90-day mortality. We found MV strategies to prevent pneumothorax including liberal use of noninvasive ventilation, and PEEP titration and disuse of mandatory ventilation may improve mortality in this setting. Underlying disease of interstitial lung disease was a risk factor and KL-6 may be a useful predictor associated with mortality in patients with RA. These findings will need to be validated in larger studies.

  15. Respiratory system mechanics in acute respiratory distress syndrome.

    PubMed

    Kallet, Richard H; Katz, Jeffrey A

    2003-09-01

    Respiratory mechanics research is important to the advancement of ARDS management. Twenty-eight years ago, research on the effects of PEEP and VT indicated that the lungs of ARDS patients did not behave in a manner consistent with homogenously distributed lung injury. Both Suter and colleagues] and Katz and colleagues reported that oxygenation continued to improve as PEEP increased (suggesting lung recruitment), even though static Crs decreased and dead-space ventilation increased (suggesting concurrent lung overdistension). This research strongly suggested that without VT reduction, the favorable effects of PEEP on lung recruitment are offset by lung overdistension at end-inspiration. The implications of these studies were not fully appreciated at that time, in part because the concept of ventilator-associated lung injury was in its nascent state. Ten years later. Gattinoni and colleagues compared measurements of static pressure-volume curves with FRC and CT scans of the chest in ARDS. They found that although PEEP recruits collapsed (primarily dorsal) lung segments, it simultaneously causes overdistension of non-dependent, inflated lung regions. Furthermore, the specific compliance of the aerated, residually healthy lung tissue is essentially normal. The main implication of these findings is that traditional mechanical ventilation practice was injecting excessive volumes of gas into functionally small lungs. Therefore, the emblematic low static Crs measured in ARDS reflects not only surface tension phenomena and recruitment of collapsed airspaces but also overdistension of the remaining healthy lung. The studies reviewed in this article support the concept that lung injury in ARDS is heterogeneously distributed, with resulting disparate mechanical stresses, and indicate the additional complexity from alterations in chest wall mechanics. Most of these studies, however, were published before lung-protective ventilation. Therefore, further studies are needed to

  16. Shorebird use of managed wetlands in the Mississippi Alluvial Valley

    USGS Publications Warehouse

    Twedt, Daniel J.; Nelms, Curtis O.; Rettig, Virginia E.; Aycock, S. Ray

    1998-01-01

    We assessed shorebird densities on managed wetland habitats during fall and winter within the primarily agricultural landscape of the Mississippi Alluvial Valley. From November through March, shorebird densities were greater on soybean fields than on rice or moist-soil fields. Killdeer (Charadrius vociferus) and Common Snipe (Gallinago gallinago) were common throughout winter, whereas Yellowlegs (Tringa spp.) and ?peep? sandpipers (Calidris spp.) were present but less abundant. During fall, Dowitchers (Limnodromus spp.), Pectoral Sandpipers (Calidris melanotos), Killdeer, and peep sandpipers were the most abundant species on managed shorebird habitat units. Although shorebird densities were consistently greater on habitats managed by drawing down existing water, we were unable to detect a significant difference in densities from areas managed by flooding previously dry habitat.

  17. Lung Transcriptomics during Protective Ventilatory Support in Sepsis-Induced Acute Lung Injury

    PubMed Central

    Acosta-Herrera, Marialbert; Lorenzo-Diaz, Fabian; Pino-Yanes, Maria; Corrales, Almudena; Valladares, Francisco; Klassert, Tilman E.; Valladares, Basilio; Slevogt, Hortense; Ma, Shwu-Fan

    2015-01-01

    Acute lung injury (ALI) is a severe inflammatory process of the lung. The only proven life-saving support is mechanical ventilation (MV) using low tidal volumes (LVT) plus moderate to high levels of positive end-expiratory pressure (PEEP). However, it is currently unknown how they exert the protective effects. To identify the molecular mechanisms modulated by protective MV, this study reports transcriptomic analyses based on microarray and microRNA sequencing in lung tissues from a clinically relevant animal model of sepsis-induced ALI. Sepsis was induced by cecal ligation and puncture (CLP) in male Sprague-Dawley rats. At 24 hours post-CLP, septic animals were randomized to three ventilatory strategies: spontaneous breathing, LVT (6 ml/kg) plus 10 cmH2O PEEP and high tidal volume (HVT, 20 ml/kg) plus 2 cmH2O PEEP. Healthy, non-septic, non-ventilated animals served as controls. After 4 hours of ventilation, lung samples were obtained for histological examination and gene expression analysis using microarray and microRNA sequencing. Validations were assessed using parallel analyses on existing publicly available genome-wide association study findings and transcriptomic human data. The catalogue of deregulated processes differed among experimental groups. The ‘response to microorganisms’ was the most prominent biological process in septic, non-ventilated and in HVT animals. Unexpectedly, the ‘neuron projection morphogenesis’ process was one of the most significantly deregulated in LVT. Further support for the key role of the latter process was obtained by microRNA studies, as four species targeting many of its genes (Mir-27a, Mir-103, Mir-17-5p and Mir-130a) were found deregulated. Additional analyses revealed 'VEGF signaling' as a central underlying response mechanism to all the septic groups (spontaneously breathing or mechanically ventilated). Based on this data, we conclude that a co-deregulation of 'VEGF signaling' along with 'neuron projection

  18. Rationale, study design and analysis plan of the lung imaging morphology for ventilator settings in acute respiratory distress syndrome study (LIVE study): Study protocol for a randomised controlled trial.

    PubMed

    Jabaudon, Matthieu; Godet, Thomas; Futier, Emmanuel; Bazin, Jean-Étienne; Sapin, Vincent; Roszyk, Laurence; Pereira, Bruno; Constantin, Jean-Michel

    2017-10-01

    Different acute respiratory distress syndrome (ARDS) phenotypes may explain controversial results in clinical trials. Lung-morphology is one of the ARDS-phenotypes and physiological studies suggest different responses in terms of positive-end-expiratory-pressure (PEEP) and recruitment-manoeuvres (RM) according to loss of aeration. To evaluate whether tailored ventilator regimens may impact ARDS outcomes, our group has designed a randomised-clinical-trial of ventilator settings according to lung morphology in moderate-to-severe ARDS (LIVE study). Patients will be enrolled within the first 12hours of ARDS onset. In both groups, volume-controlled ventilation with low tidal-volumes (Vt) will be used to target a plateau pressure≤30 cmH 2 O. In the control group, the PEEP level and inspired fraction of oxygen (FiO 2 ) will be set using the ARDSNet table; a Vt of 6 mL/kg of predicted body weight (PBW) will be set and prone position (PP) will be applied. In the intervention arm, the ventilator will be set according to lung morphology (focal/non-focal) that will be assessed according to CT-scan±chest x-ray+lung echography. For focal ARDS patients, a Vt of 8 mL/kg PBW will be used along with low PEEP and PP. For non-focal ARDS patients, a Vt of 6 mL/kg PBW will be used with RM and PEEP to reach a plateau pressure≤30 cmH 2 O. The primary outcome is all-cause 90-day mortality and the secondary outcomes are: in-hospital mortality, mortality at day 28, 60, 180 and 365; ventilator-free days at day 30, quality of life at one year; ventilator-associated pneumonia rate; barotrauma; ICU and hospital length of stay. This RCT is registered on Clinicaltrials.gov under identifier NCT02149589. Copyright © 2017 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  19. Production of Energy Efficient Preform Structures (PEEPS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. John A. Baumann

    2012-06-08

    Due to its low density, good structural characteristics, excellent fabrication properties, and attractive appearance, aluminum metal and its alloys continue to be widely utilized. The transportation industry continues to be the largest consumer of aluminum products, with aerospace as the principal driver for this use. Boeing has long been the largest single company consumer of heat-treated aluminum in the U.S. The extensive use of aluminum to build aircraft and launch vehicles has been sustained, despite the growing reliance on more structurally efficient carbon fiber reinforced composite materials. The trend in the aerospace industry over the past several decades has beenmore » to rely extensively on large, complex, thin-walled, monolithic machined structural components, which are fabricated from heavy billets and thick plate using high speed machining. The use of these high buy-to-fly ratio starting product forms, while currently cost effective, is energy inefficient, with a high environmental impact. The widespread implementation of Solid State Joining (SSJ) technologies, to produce lower buy-to-fly ratio starting forms, tailored to each specific application, offers the potential for a more sustainable manufacturing strategy, which would consume less energy, require less material, and reduce material and manufacturing costs. One objective of this project was to project the energy benefits of using SSJ techniques to produce high-performance aluminum structures if implemented in the production of the world fleet of commercial aircraft. A further objective was to produce an energy consumption prediction model, capable of calculating the total energy consumption, solid waste burden, acidification potential, and CO2 burden in producing a starting product form - whether by conventional or SSJ processes - and machining that to a final part configuration. The model needed to be capable of computing and comparing, on an individual part/geometry basis, multiple possible manufacturing pathways, to identify the best balance of energy consumption and environmental impact. This model has been created and populated with energy consumption data for individual SSJ processes and process platforms. Technology feasibility cases studies were executed, to validate the model, and confirm the ability to create lower buy-to-fly ratio performs and machine these to final configuration aircraft components. This model can now be used as a tool to select manufacturing pathways that offer significant energy savings and, when coupled with a cost model, drive implementation of the SSJ processes.« less

  20. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    PubMed

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  1. Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT).

    PubMed

    Shi, Chang; Boehme, Stefan; Bentley, Alexander H; Hartmann, Erik K; Klein, Klaus U; Bodenstein, Marc; Baumgardner, James E; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of -1.07±24.71 ml and limits of agreement of -49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.

  2. Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia.

    PubMed

    Ersoy, Ayşın; Çakırgöz, Mensure; Ervatan, Zekeriya; Kıran, Özlem; Türkmen, Aygen; Esenyel, Cem Zeki

    2016-01-01

    Our study is a prospective, randomized study on patients undergoing arthroscopic shoulder surgery in the beach-chair position to evaluate the effects of positive end-expiratory pressure (PEEP) on hemodynamic stability, providing a bloodless surgical field and surgical satisfaction. Fifty patients were divided into two groups. Group I (n=25) had zero end-expiratory pressure (ZEEP) administered under general anesthesia, and group II (n=25) had +5 PEEP administered. During surgery, intraarticular hemorrhage and surgical satisfaction were evaluated on a scale of 0-10. During surgery, at the 5th, 30th, 60th, and 90th minutes and at the end of surgery, heart rate, mean arterial pressure (MAP), and positive inspiratory pressure were recorded. At the end of the surgery, the amount of bleeding and duration of the operation were recorded. In group I, the duration of operation and amount of bleeding were found to be significantly greater than those in group II (p<0.05). The surgical satisfaction score and clarity of the surgical field were found to be significantly lower in group I than in group II (p<0.05). MAP values in group I were significantly lower than those in group II. The SPO² values in group I were significantly lower than those in group II. Adding PEEP to the ventilation parameters of arthroscopic shoulder surgery in the beach-chair position reduces the amount of hemorrhage in the surgical field and thus increases surgical satisfaction without requiring the creation of controlled hypotension.

  3. Alteration in transthoracic impedance following cardiac surgery.

    PubMed

    Khan, Nouman U; Strang, Tim; Bonsheck, Claire; Krishnamurty, Bhuvana; Hooper, Timothy L

    2008-06-01

    Haemodynamically significant ventricular tachyarrhythmias are a frequent complication in the immediate post-operative period after cardiac surgery. Successful cardioversion depends on delivery of sufficient current, which in turn is dependent on transthoracic impedance (TTI). However, it is uncertain if there is a change in TTI immediately following cardiac surgery using cardiopulmonary bypass (CPB). TTI was measured on 40 patients undergoing first time isolated cardiac surgery using CPB. TTI was recorded at 30 kHz using Bodystat Multiscan 5000 equipment before operation (with and without a positive end-expiratory pressure (PEEP) of 5 cm of H(2)O) and then at 1, 4 and 24 h after the operation. Data was analyzed to determine the relationship between pre- and post-operative variables and TTI values. Mean pre-operative TTI was 54.5+/-10.55 ohms without PEEP and 61.8+/-15.4 ohms on a PEEP of 5 cm of H(2)O. TTI dropped significantly (p<0.001) after the operation to 47.2+/-10.6 ohms at 1 h, 42.6+/-10.2 ohms at 4 h and 41.8+/-10.4 ohms at 24 h. A positive correlation was noted between duration of operation and TTI change at 1 h (r=0.38; p=0.016). There was no significant correlation between the duration of bypass and change in TTI. TTI decreases by more than 30% in the immediate post-operative period following cardiac surgery. This state may favour defibrillation at lower energy levels.

  4. Lung Recruitment Assessed by Respiratory Mechanics and Computed Tomography in Patients with Acute Respiratory Distress Syndrome. What Is the Relationship?

    PubMed

    Chiumello, Davide; Marino, Antonella; Brioni, Matteo; Cigada, Irene; Menga, Federica; Colombo, Andrea; Crimella, Francesco; Algieri, Ilaria; Cressoni, Massimo; Carlesso, Eleonora; Gattinoni, Luciano

    2016-06-01

    The assessment of lung recruitability in patients with acute respiratory distress syndrome (ARDS) may be important for planning recruitment maneuvers and setting positive end-expiratory pressure (PEEP). To determine whether lung recruitment measured by respiratory mechanics is comparable with lung recruitment measured by computed tomography (CT). In 22 patients with ARDS, lung recruitment was assessed at 5 and 15 cm H2O PEEP by using respiratory mechanics-based methods: (1) increase in gas volume between two pressure-volume curves (P-Vrs curve); (2) increase in gas volume measured and predicted on the basis of expected end-expiratory lung volume and static compliance of the respiratory system (EELV-Cst,rs); as well as by CT scan: (3) decrease in noninflated lung tissue (CT [not inflated]); and (4) decrease in noninflated and poorly inflated tissue (CT [not + poorly inflated]). The P-Vrs curve recruitment was significantly higher than EELV-Cst,rs recruitment (423 ± 223 ml vs. 315 ± 201 ml; P < 0.001), but these measures were significantly related to each other (R(2) = 0.93; P < 0.001). CT (not inflated) recruitment was 77 ± 86 g and CT (not + poorly inflated) was 80 ± 67 g (P = 0.856), and these measures were also significantly related to each other (R(2) = 0.20; P = 0.04). Recruitment measured by respiratory mechanics was 54 ± 28% (P-Vrs curve) and 39 ± 25% (EELV-Cst,rs) of the gas volume at 5 cm H2O PEEP. Recruitment measured by CT scan was 5 ± 5% (CT [not inflated]) and 6 ± 6% (CT [not + poorly inflated]) of lung tissue. Respiratory mechanics and CT measure-under the same term, "recruitment"-two different entities. The respiratory mechanics-based methods include gas entering in already open pulmonary units that improve their mechanical properties at higher PEEP. Consequently, they can be used to assess the overall improvement of inflation. The CT scan measures the amount of collapsed

  5. Fluorescent supramolecular micelles for imaging-guided cancer therapy

    NASA Astrophysics Data System (ADS)

    Sun, Mengmeng; Yin, Wenyan; Dong, Xinghua; Yang, Wantai; Zhao, Yuliang; Yin, Meizhen

    2016-02-01

    A novel smart fluorescent drug delivery system composed of a perylene diimide (PDI) core and block copolymer poly(d,l-lactide)-b-poly(ethyl ethylene phosphate) is developed and named as PDI-star-(PLA-b-PEEP)8. The biodegradable PDI-star-(PLA-b-PEEP)8 is a unimolecular micelle and can self-assemble into supramolecular micelles, called as fluorescent supramolecular micelles (FSMs), in aqueous media. An insoluble drug camptothecin (CPT) can be effectively loaded into the FSMs and exhibits pH-responsive release. Moreover, the FSMs with good biocompatibility can also be employed as a remarkable fluorescent probe for cell labelling because the maximum emission of PDI is beneficial for bio-imaging. The flow cytometry and confocal laser scanning microscopy analysis demonstrate that the micelles are easily endocytosed by cancer cells. In vitro and in vivo tumor growth-inhibitory studies reveal a better therapeutic effect of FSMs after CPT encapsulation when compared with the free CPT drug. The multifunctional FSM nanomedicine platform as a nanovehicle has great potential for fluorescence imaging-guided cancer therapy.A novel smart fluorescent drug delivery system composed of a perylene diimide (PDI) core and block copolymer poly(d,l-lactide)-b-poly(ethyl ethylene phosphate) is developed and named as PDI-star-(PLA-b-PEEP)8. The biodegradable PDI-star-(PLA-b-PEEP)8 is a unimolecular micelle and can self-assemble into supramolecular micelles, called as fluorescent supramolecular micelles (FSMs), in aqueous media. An insoluble drug camptothecin (CPT) can be effectively loaded into the FSMs and exhibits pH-responsive release. Moreover, the FSMs with good biocompatibility can also be employed as a remarkable fluorescent probe for cell labelling because the maximum emission of PDI is beneficial for bio-imaging. The flow cytometry and confocal laser scanning microscopy analysis demonstrate that the micelles are easily endocytosed by cancer cells. In vitro and in vivo tumor growth

  6. Respiratory mechanics in infants with severe bronchiolitis on controlled mechanical ventilation.

    PubMed

    Cruces, Pablo; González-Dambrauskas, Sebastián; Quilodrán, Julio; Valenzuela, Jorge; Martínez, Javier; Rivero, Natalia; Arias, Pablo; Díaz, Franco

    2017-10-06

    Analysis of respiratory mechanics during mechanical ventilation (MV) is able to estimate resistive, elastic and inertial components of the working pressure of the respiratory system. Our aim was to discriminate the components of the working pressure of the respiratory system in infants on MV with severe bronchiolitis admitted to two PICU's. Infants younger than 1 year old with acute respiratory failure caused by severe bronchiolitis underwent neuromuscular blockade, tracheal intubation and volume controlled MV. Shortly after intubation studies of pulmonary mechanics were performed using inspiratory and expiratory breath hold. The maximum inspiratory and expiratory flow (QI and QE) as well as peak inspiratory (PIP), plateau (PPL) and total expiratory pressures (tPEEP) were measured. Inspiratory and expiratory resistances (RawI and RawE) and Time Constants (K TI and K TE ) were calculated. We included 16 patients, of median age 2.5 (1-5.8) months. Bronchiolitis due to respiratory syncytial virus was the main etiology (93.8%) and 31.3% had comorbidities. Measured respiratory pressures were PIP 29 (26-31), PPL 24 (20-26), tPEEP 9 [8-11] cmH2O. Elastic component of the working pressure was significantly higher than resistive and both higher than threshold (tPEEP - PEEP) (P < 0.01). QI was significantly lower than QE [5 (4.27-6.75) v/s 16.5 (12-23.8) L/min. RawI and RawE were 38.8 (32-53) and 40.5 (22-55) cmH2O/L/s; K TI and K TE [0.18 (0.12-0.30) v/s 0.18 (0.13-0.22) s], and K TI :K TE ratio was 1:1.04 (1:0.59-1.42). Analysis of respiratory mechanics of infants with severe bronchiolitis receiving MV shows that the elastic component of the working pressure of the respiratory system is the most important. The elastic and resistive components in conjunction with flow profile are characteristic of restrictive diseases. A better understanding of lung mechanics in this group of patients may lead to change the traditional ventilatory approach to severe bronchiolitis.

  7. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  8. Particle size concentration distribution and influences on exhaled breath particles in mechanically ventilated patients.

    PubMed

    Wan, Gwo-Hwa; Wu, Chieh-Liang; Chen, Yi-Fang; Huang, Sheng-Hsiu; Wang, Yu-Ling; Chen, Chun-Wan

    2014-01-01

    Humans produce exhaled breath particles (EBPs) during various breath activities, such as normal breathing, coughing, talking, and sneezing. Airborne transmission risk exists when EBPs have attached pathogens. Until recently, few investigations had evaluated the size and concentration distributions of EBPs from mechanically ventilated patients with different ventilation mode settings. This study thus broke new ground by not only evaluating the size concentration distributions of EBPs in mechanically ventilated patients, but also investigating the relationship between EBP level and positive expiratory end airway pressure (PEEP), tidal volume, and pneumonia. This investigation recruited mechanically ventilated patients, with and without pneumonia, aged 20 years old and above, from the respiratory intensive care unit of a medical center. Concentration distributions of EBPs from mechanically ventilated patients were analyzed with an optical particle analyzer. This study finds that EBP concentrations from mechanically ventilated patients during normal breathing were in the range 0.47-2,554.04 particles/breath (0.001-4.644 particles/mL). EBP concentrations did not differ significantly between the volume control and pressure control modes of the ventilation settings in the mechanically ventilated patients. The patient EBPs were sized below 5 µm, and 80% of them ranged from 0.3 to 1.0 µm. The EBPs concentrations in patients with high PEEP (> 5 cmH₂O) clearly exceeded those in patients with low PEEP (≤ 5 cmH₂O). Additionally, a significant negative association existed between pneumonia duration and EBPs concentration. However, tidal volume was not related to EBPs concentration.

  9. Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)

    PubMed Central

    Bentley, Alexander H.; Hartmann, Erik K.; Klein, Klaus U.; Bodenstein, Marc; Baumgardner, James E.; David, Matthias; Ullrich, Roman; Markstaller, Klaus

    2014-01-01

    Background Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. Methodology/Principal Findings Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT. Conclusions/Significance Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT. PMID:24475160

  10. Mechanical ventilation in abdominal surgery.

    PubMed

    Futier, E; Godet, T; Millot, A; Constantin, J-M; Jaber, S

    2014-01-01

    One of the key challenges in perioperative care is to reduce postoperative morbidity and mortality. Patients who develop postoperative morbidity but survive to leave hospital have often reduced functional independence and long-term survival. Mechanical ventilation provides a specific example that may help us to shift thinking from treatment to prevention of postoperative complications. Mechanical ventilation in patients undergoing surgery has long been considered only as a modality to ensure gas exchange while allowing maintenance of anesthesia with delivery of inhaled anesthetics. Evidence is accumulating, however, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary function and clinical outcome in patients undergoing abdominal surgery. Non-protective ventilator settings, especially high tidal volume (VT) (>10-12mL/kg) and the use of very low level of positive end-expiratory pressure (PEEP) (PEEP<5cmH2O) or no PEEP, may cause alveolar overdistension and repetitive tidal recruitment leading to ventilator-associated lung injury in patients with healthy lungs. Stimulated by previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung protective mechanical ventilation. In this review, we aimed at providing the most recent and relevant clinical evidence regarding the use of mechanical ventilation in patients undergoing abdominal surgery. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  11. Airway Strain during Mechanical Ventilation in an Intact Animal Model

    PubMed Central

    Sinclair, Scott E.; Molthen, Robert C.; Haworth, Steve T.; Dawson, Christopher A.; Waters, Christopher M.

    2007-01-01

    Rationale: Mechanical ventilation with large tidal volumes causes ventilator-induced lung injury in animal models. Little direct evidence exists regarding the deformation of airways in vivo during mechanical ventilation, or in the presence of positive end-expiratory pressure (PEEP). Objectives: To measure airway strain and to estimate airway wall tension during mechanical ventilation in an intact animal model. Methods: Sprague-Dawley rats were anesthetized and mechanically ventilated with tidal volumes of 6, 12, and 25 cm3/kg with and without 10–cm H2O PEEP. Real-time tantalum bronchograms were obtained for each condition, using microfocal X-ray imaging. Images were used to calculate circumferential and longitudinal airway strains, and on the basis of a simplified mathematical model we estimated airway wall tensions. Measurements and Main Results: Circumferential and longitudinal airway strains increased with increasing tidal volume. Levels of mechanical strain were heterogeneous throughout the bronchial tree. Circumferential strains were higher in smaller airways (less than 800 μm). Airway size did not influence longitudinal strain. When PEEP was applied, wall tensions increased more rapidly than did strain levels, suggesting that a “strain limit” had been reached. Airway collapse was not observed under any experimental condition. Conclusions: Mechanical ventilation results in significant airway mechanical strain that is heterogeneously distributed in the uninjured lung. The magnitude of circumferential but not axial strain varies with airway diameter. Airways exhibit a “strain limit” above which an abrupt dramatic rise in wall tension is observed. PMID:17626911

  12. Intratidal Overdistention and Derecruitment in the Injured Lung: A Simulation Study.

    PubMed

    Amini, Reza; Herrmann, Jacob; Kaczka, David W

    2017-03-01

    Ventilated patients with the acute respiratory distress syndrome (ARDS) are predisposed to cyclic parenchymal overdistention and derecruitment, which may worsen existing injury. We hypothesized that intratidal variations in global mechanics, as assessed at the airway opening, would reflect such distributed processes. We developed a computational lung model for determining local instantaneous pressure distributions and mechanical impedances continuously during a breath. Based on these distributions and previous literature, we simulated the within-breath variability of airway segment dimensions, parenchymal viscoelasticity, and acinar recruitment in an injured canine lung for tidal volumes( V T ) of 10, 15, and 20 mL·kg -1 and positive end-expiratory pressures (PEEP) of 5, 10, and 15 cm H 2 O. Acini were allowed to transition between recruited and derecruited states when exposed to stochastically determined critical opening and closing pressures, respectively. For conditions of low V T and low PEEP, we observed small intratidal variations in global resistance and elastance, with a small number of cyclically recruited acini. However, with higher V T and PEEP, larger variations in resistance and elastance were observed, and the majority of acini remained open throughout the breath. Changes in intratidal resistance, elastance, and impedance followed well-defined parabolic trajectories with tracheal pressure, achieving minima near 12 to 16 cm H 2 O. Intratidal variations in lung mechanics may allow for optimization of ventilator settings in patients with ARDS, by balancing lung recruitment against parenchymal overdistention. Titration of airway pressures based on variations in intratidal mechanics may mitigate processes associated with injurious ventilation.

  13. Reliability of transpulmonary pressure-time curve profile to identify tidal recruitment/hyperinflation in experimental unilateral pleural effusion.

    PubMed

    Formenti, P; Umbrello, M; Graf, J; Adams, A B; Dries, D J; Marini, J J

    2017-08-01

    The stress index (SI) is a parameter that characterizes the shape of the airway pressure-time profile (P/t). It indicates the slope progression of the curve, reflecting both lung and chest wall properties. The presence of pleural effusion alters the mechanical properties of the respiratory system decreasing transpulmonary pressure (Ptp). We investigated whether the SI computed using Ptp tracing would provide reliable insight into tidal recruitment/overdistention during the tidal cycle in the presence of unilateral effusion. Unilateral pleural effusion was simulated in anesthetized, mechanically ventilated pigs. Respiratory system mechanics and thoracic computed tomography (CT) were studied to assess P/t curve shape and changes in global lung aeration. SI derived from airway pressure (Paw) was compared with that calculated by Ptp under the same conditions. These results were themselves compared with quantitative CT analysis as a gold standard for tidal recruitment/hyperinflation. Despite marked changes in tidal recruitment, mean values of SI computed either from Paw or Ptp were remarkably insensitive to variations of PEEP or condition. After the instillation of effusion, SI indicates a preponderant over-distension effect, not detected by CT. After the increment in PEEP level, the extent of CT-determined tidal recruitment suggest a huge recruitment effect of PEEP as reflected by lung compliance. Both SI in this case were unaffected. We showed that the ability of SI to predict tidal recruitment and overdistension was significantly reduced in a model of altered chest wall-lung relationship, even if the parameter was computed from the Ptp curve profile.

  14. Early Phonological Development: Creating an Assessment Test

    ERIC Educational Resources Information Center

    Stoel-Gammon, Carol; Williams, A. Lynn

    2013-01-01

    This paper describes a new protocol for assessing the phonological systems of two-year-olds with typical development and older children with delays in vocabulary acquisition. The test (Profiles of Early Expressive Phonological Skills ("PEEPS"), Williams & Stoel-Gammon, in preparation) differs from currently available assessments in…

  15. Linking lung function to structural damage of alveolar epithelium in ventilator-induced lung injury.

    PubMed

    Hamlington, Katharine L; Smith, Bradford J; Dunn, Celia M; Charlebois, Chantel M; Roy, Gregory S; Bates, Jason H T

    2018-05-06

    Understanding how the mechanisms of ventilator-induced lung injury (VILI), namely atelectrauma and volutrauma, contribute to the failure of the blood-gas barrier and subsequent intrusion of edematous fluid into the airspace is essential for the design of mechanical ventilation strategies that minimize VILI. We ventilated mice with different combinations of tidal volume and positive end-expiratory pressure (PEEP) and linked degradation in lung function measurements to injury of the alveolar epithelium observed via scanning electron microscopy. Ventilating with both high inspiratory plateau pressure and zero PEEP was necessary to cause derangements in lung function as well as visually apparent physical damage to the alveolar epithelium of initially healthy mice. In particular, the epithelial injury was tightly associated with indicators of alveolar collapse. These results support the hypothesis that mechanical damage to the epithelium during VILI is at least partially attributed to atelectrauma-induced damage of alveolar type I epithelial cells. Copyright © 2018. Published by Elsevier B.V.

  16. Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.

    PubMed

    Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan

    2013-01-14

    The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.

  17. Mechanical breath profile of airway pressure release ventilation: the effect on alveolar recruitment and microstrain in acute lung injury.

    PubMed

    Kollisch-Singule, Michaela; Emr, Bryanna; Smith, Bradford; Roy, Shreyas; Jain, Sumeet; Satalin, Joshua; Snyder, Kathy; Andrews, Penny; Habashi, Nader; Bates, Jason; Marx, William; Nieman, Gary; Gatto, Louis A

    2014-11-01

    Improper mechanical ventilation settings can exacerbate acute lung injury by causing a secondary ventilator-induced lung injury. It is therefore important to establish the mechanism by which the ventilator induces lung injury to develop protective ventilation strategies. It has been postulated that the mechanism of ventilator-induced lung injury is the result of heterogeneous, elevated strain on the pulmonary parenchyma. Acute lung injury has been associated with increases in whole-lung macrostrain, which is correlated with increased pathology. However, the effect of mechanical ventilation on alveolar microstrain remains unknown. To examine whether the mechanical breath profile of airway pressure release ventilation (APRV), consisting of a prolonged pressure-time profile and brief expiratory release phase, reduces microstrain. In a randomized, nonblinded laboratory animal study, rats were randomized into a controlled mandatory ventilation group (n = 3) and an APRV group (n = 3). Lung injury was induced by polysorbate lavage. A thoracotomy was performed and an in vivo microscope was placed on the lungs to measure alveolar mechanics. In the controlled mandatory ventilation group, multiple levels of positive end-expiratory pressure (PEEP; 5, 10, 16, 20, and 24 cm H2O) were tested. In the APRV group, decreasing durations of expiratory release (time at low pressure [T(low)]) were tested. The T(low) was set to achieve ratios of termination of peak expiratory flow rate (T-PEFR) to peak expiratory flow rate (PEFR) of 10%, 25%, 50%, and 75% (the smaller this ratio is [ie, 10%], the more time the lung is exposed to low pressure during the release phase, which decreases end-expiratory lung volume and potentiates derecruitment). Alveolar perimeters were measured at peak inspiration and end expiration using digital image analysis, and strain was calculated by normalizing the change in alveolar perimeter length to the original length. Macrostrain was measured by volume

  18. Wavelet pressure reactivity index: A validation study.

    PubMed

    Liu, Xiuyun; Czosnyka, Marek; Donnelly, Joseph; Cardim, Danilo; Cabeleira, Manuel; Hutchinson, Peter J; Hu, Xiao; Smielewski, Peter; Brady, Ken

    2018-04-17

    The brain is vulnerable to damage from too little or too much blood flow. A physiological mechanism called cerebral autoregulation (CA) exists to maintain stable blood flow even if cerebral perfusion pressure (CPP) is changing. A robust method for assessing CA is not yet available. There are still some problems with the traditional measure, the pressure reactivity index (PRx). We introduced a new method, wavelet transform method (wPRx) to assess CA using data from two sets of controlled hypotension experiments in piglets: One set with artificially manipulated ABP oscillations; the other group were spontaneous ABP waves. A significant linear relationship was found between wPRx and PRx in both groups, with wPRx rendering a more stable result for the spontaneous waves. Although both methods showed similar accuracy in distinguishing intact and impaired CA, it seems that wPRx tend to perform better than PRx, though not significantly. We present a novel method to monitor cerebral autoregulation (CA) using the wavelet transform (WT). The new method is validated against the pressure reactivity index (PRx) in two piglet experiments with controlled hypotension. The first experiment (n = 12) had controlled haemorrhage with artificial stationary arterial blood pressure (ABP) and intracranial pressure (ICP) oscillations induced by sinusoidal slow changes in positive end-expiratory pressure ('PEEP group') . The second experiment (n = 17) had venous balloon inflation during spontaneous, non-stationary ABP and ICP oscillations ('non-PEEP group'). Wavelet transform phase shift (WTP) between ABP and ICP was calculated in the frequency 0.0067-0.05 Hz. Wavelet semblance, the cosine of WTP was used to make the values comparable to PRx, and the new index was termed wavelet pressure reactivity index (wPRx). The traditional PRx, the running correlation coefficient between ABP and ICP, was calculated. The result showed a significant linear relationship between wPRx and PRx in the PEEP

  19. Implementation of a Goal-Directed Mechanical Ventilation Order Set Driven by Respiratory Therapists Improves Compliance With Best Practices for Mechanical Ventilation.

    PubMed

    Radosevich, Misty A; Wanta, Brendan T; Meyer, Todd J; Weber, Verlin W; Brown, Daniel R; Smischney, Nathan J; Diedrich, Daniel A

    2017-01-01

    Data regarding best practices for ventilator management strategies that improve outcomes in acute respiratory distress syndrome (ARDS) are readily available. However, little is known regarding processes to ensure compliance with these strategies. We developed a goal-directed mechanical ventilation order set that included physician-specified lung-protective ventilation and oxygenation goals to be implemented by respiratory therapists (RTs). We sought as a primary outcome to determine whether an RT-driven order set with predefined oxygenation and ventilation goals could be implemented and associated with improved adherence with best practice. We evaluated 1302 patients undergoing invasive mechanical ventilation (1693 separate episodes of invasive mechanical ventilation) prior to and after institution of a standardized, goal-directed mechanical ventilation order set using a controlled before-and-after study design. Patient-specific goals for oxygenation partial pressure of oxygen in arterial blood (Pao 2 ), ARDS Network [Net] positive end-expiratory pressure [PEEP]/fraction of inspired oxygen [Fio 2 ] table use) and ventilation (pH, partial pressure of carbon dioxide) were selected by prescribers and implemented by RTs. Compliance with the new mechanical ventilation order set was high: 88.2% compliance versus 3.8% before implementation of the order set ( P < .001). Adherence to the PEEP/Fio 2 table after implementation of the order set was significantly greater (86.0% after vs 82.9% before, P = .02). There was no difference in duration of mechanical ventilation, intensive care unit (ICU) length of stay, and in-hospital or ICU mortality. A standardized best practice mechanical ventilation order set can be implemented by a multidisciplinary team and is associated with improved compliance to written orders and adherence to the ARDSNet PEEP/Fio 2 table.

  20. Mechanical Ventilation in Patients with the Acute Respiratory Distress Syndrome and Treated with Extracorporeal Membrane Oxygenation: Impact on Hospital and 30 Day Postdischarge Survival.

    PubMed

    Modrykamien, Ariel M; Hernandez, Omar O; Im, Yunhee; Walters, Ryan W; Schrader, Caleb L; Smith, Lauren E; Lima, Brian

    2016-01-01

    Mechanical ventilation support for acute respiratory distress syndrome (ARDS) patients involves the use of low tidal volumes and positive end-expiratory pressure. Nevertheless, the optimal ventilator strategy for ARDS patients undergoing extracorporeal membrane oxygenation (ECMO) therapy remains unknown. A retrospective analysis of a consecutive series of adult ARDS patients treated with V-V ECMO from October 2012 to May 2015 was performed. Mechanical ventilation data, as well as demographic and clinical data, were collected. We assessed the association between ventilator data and outcomes of interest. The primary outcome was hospital survival. Secondary outcome was 30 day survival posthospital discharge. Sixty-four ARDS patients were treated with ECMO. Univariate analysis showed that plateau pressure was independently associated with hospital survival. Tidal volume, positive end-expiratory pressure (PEEP), and plateau were independently associated with 30 day survival. Multivariate analysis, after controlling for covariates, revealed that a 1 unit increase in plateau pressure was associated with a 21% decrease in the odds of hospital survival (95% confidence interval [CI] = 6.39-33.42%, p = 0.007). In regards to 30 day survival postdischarge, a 1 unit increase in plateau pressure was associated with a 14.4% decrease in the odds of achieving the aforementioned outcome (95% CI = 1.75-25.4%, p = 0.027). Also, a 1 unit increase in PEEP was associated with a 36.2% decrease in the odds of 30 day survival (95% CI = 10.8-54.4%, p = 0.009). Among ARDS patients undergoing ECMO therapy, only plateau pressure is associated with hospital survival. Plateau pressure and PEEP are both associated with 30 day survival posthospital discharge.

  1. Piedmont Export Expansion Program Monograph: A Final Report.

    ERIC Educational Resources Information Center

    Brown, Ralph W., Jr.; Peniche, Eduardo A.

    The Piedmont Export Expansion Program (PEEP) was developed to increase the number of businesses in central Virginia entering or expanding export trade; to increase the utilization of the services of Central Virginia Community College's (CVCC's) Cross-Cultural and Foreign Language Resource Center by area export businesses; to increase the number of…

  2. Guadalcanal Operation. Volume 2

    DTIC Science & Technology

    1943-01-01

    latest being a large peep baltle sight and leaf , permitting quick sighting. The sling was of a lacquered tight web. A cleaning rod snapped into the...defense along the Lunga would be by battalions, First, Second and Third, The First Battalion crossed the Ilu River in the vicinity of tli;-: Papaya

  3. Formative Evaluation of Lectures; An Application of Stake's Evaluation Framework.

    ERIC Educational Resources Information Center

    Westphal, Walter W.; And Others

    The problem of major concern to the Physics Education Evaluation Project (P.E.E.P.) involved the improvement of university physics teaching and learning. The present paper describes instruments and procedures developed for systematic formative evaluation of physics lectures. The data was drawn from two sections of a first year university physics…

  4. Clinical factors affecting inspired gas humidification and oral dryness during noninvasive ventilation.

    PubMed

    Oto, Jun; Imanaka, Hideaki; Nishimura, Masaji

    2011-10-01

    Oral dryness is a common complication during noninvasive ventilation (NIV). We measured the oral dryness of patients and performed a bench study to investigate factors related to humidification during NIV. Patients were randomly assigned into 2 groups: medium (Med group) and maximum (Max group) heated humidifier (HH) settings. Oral moistness was measured using an oral moisture-checking device, and the feeling of oral dryness was evaluated using a 0 to 10 numerical rating scale (NRS) at 0, 12, and 24 hours from the beginning of NIV and at 12 and 24 hours after NIV was discontinued. A bench study was performed to assess the effects of positive end-expiratory pressure (PEEP), the fraction of inspired oxygen (F(I)O(2)), and air leaks on absolute humidity. We evaluated 3 HH settings: no HH, HH at the medium setting, and HH at the maximum setting. The temperature in the outlet chamber was 31°C to 32°C for the medium HH setting and 38°C to 41°C for the maximum HH setting. In the clinical study, 12 patients were assigned to the Med group and 11 to the Max group. In the Med group, oral moistness decreased and NRS increased at 12 and 24 hours compared with 0 hours (P < .05). In the Max group, neither the oral moistness nor the NRS changed throughout the study period, whereas in the bench study, high F(I)O(2), high PEEP, and air leak decreased the absolute humidity for both HH settings (P < .01). However, it is not clear to what extent these factors affected the patients' oral dryness because the ranges of F(I)O(2) and PEEP were narrow. Oral dryness was a common problem in our patients. The HH setting significantly affected humidification and oral dryness during NIV. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Post-operative atelectasis - a randomised trial investigating a ventilatory strategy and low oxygen fraction during recovery.

    PubMed

    Edmark, L; Auner, U; Lindbäck, J; Enlund, M; Hedenstierna, G

    2014-07-01

    Atelectasis is common during and after general anaesthesia. We hypothesized that a ventilation strategy with a combination of 1) continuous positive airway pressure (CPAP) or positive end-expiratory pressure (PEEP) and 2) a reduced end-expiratory oxygen concentration during recovery would reduce post-operative atelectasis. Sixty patients were randomized into two groups. During anaesthesia induction, inspiratory oxygen fraction (FIO2) was 1.0, and depending on weight, CPAP 6, 7 or 8 cmH2O was applied in both groups via facemask. During maintenance of anaesthesia, a laryngeal mask airway (LMA) was used, and PEEP was 6-8 cmH2O in both groups. Before removal of the LMA, FIO2 was set to 0.3 in the intervention group and 1.0 in the control group. Atelectasis was studied by computed tomography (CT) approximately 14 min post-operatively. In one patient in the group given an FIO2 of 0.3 before removal of the LMA a CT scan could not be performed so the patient was excluded. The area of atelectasis was 5.5, 0-16.9 cm(2) (median and range), and 6.8, 0-27.5 cm(2) in the groups given FIO2 0.3 or FIO2 1.0 before removal of the LMA, a difference that was not statistically significant (P = 0.48). Post-hoc analysis showed dependence of atelectasis on smoking (despite all were clinically lung healthy) and American Society of Anesthesiologists class (P = 0.038 and 0.015, respectively). Inducing anaesthesia with CPAP/PEEP and FIO2 1.0 and deliberately reducing FIO2 during recovery before removal of the LMA did not reduce post-operative atelectasis compared with FIO2 1.0 before removal of the LMA. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  6. Respiratory Management of Perioperative Obese Patients.

    PubMed

    Imber, David Ae; Pirrone, Massimiliano; Zhang, Changsheng; Fisher, Daniel F; Kacmarek, Robert M; Berra, Lorenzo

    2016-12-01

    With a rising incidence of obesity in the United States, anesthesiologists are faced with a larger volume of obese patients coming to the operating room as well as obese patients with ever-larger body mass indices (BMIs). While there are many cardiovascular and endocrine issues that clinicians must take into account when caring for the obese patient, one of the most prominent concerns of the anesthesiologist in the perioperative setting should be the status of the lung. Because the pathophysiology of reduced lung volumes in the obese patient differs from that of the ARDS patient, the best approach to keeping the obese patient's lung open and adequately ventilated during mechanical ventilation is unique. Although strong evidence and research are lacking regarding how to best ventilate the obese surgical patient, we aim with this review to provide an assessment of the small amount of research that has been conducted and the pathophysiology we believe influences the apparent results. We will provide a basic overview of the anatomy and pathophysiology of the obese respiratory system and review studies concerning pre-, intra-, and postoperative respiratory care. Our focus in this review centers on the best approach to keeping the lung recruited through the prevention of compression atelectasis and the maintaining of physiological lung volumes. We recommend the use of PEEP via noninvasive ventilation (NIV) before induction and endotracheal intubation, the use of both PEEP and periodic recruitment maneuvers during mechanical ventilation, and the use of PEEP via NIV after extubation. It is our hope that by studying the underlying mechanisms that make ventilating obese patients so difficult, future research can be better tailored to address this increasingly important challenge to the field of anesthesia. Copyright © 2016 by Daedalus Enterprises.

  7. Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients.

    PubMed

    Wirth, Steffen; Biesemann, Andreas; Spaeth, Johannes; Schumann, Stefan

    2017-02-01

    Pneumoperitoneum during laparoscopic surgery leads to atelectasis and impairment of oxygenation. Positive end-expiratory pressure (PEEP) is supposed to counteract atelectasis. We hypothesized that the derecruiting effects of pneumoperitoneum would deteriorate the intratidal compliance profile in patients undergoing laparoscopic surgery. In 30 adult patients scheduled for surgery with pneumoperitoneum, respiratory variables were measured during mechanical ventilation. We calculated the dynamic compliance of the respiratory system (C RS ) and the intratidal volume-dependent C RS curve using the gliding-SLICE method. The C RS curve was then classified in terms of indicating intratidal recruitment/derecruitment (increasing profile) and overdistension (decreasing profile). During the surgical interventions, the PEEP level was maintained nearly constant at 7 cm H 2 O. Data are expressed as mean [confidence interval]. Baseline C RS was 60 [54-67] mL cm H 2 O -1 . Application of pneumoperitoneum decreased C RS to 40 [37-43] mL cm H 2 O -1 which partially recovered to 54 [50-59] mL cm H 2 O -1 (P < 0.001) after removal but remained below the value measured before pneumoperitoneum (P < 0.001). Baseline compliance profiles indicated intratidal recruitment/derecruitment in 48 % patients. After induction of pneumoperitoneum, intratidal recruitment/derecruitment was indicated in 93 % patients (P < 0.01), and after removal intratidal recruitment/derecruitment was indicated in 59 % patients. Compliance profiles showing overdistension were not observed. Analyses of the intratidal compliance profiles reveal that pneumoperitoneum during laparoscopic surgery causes intratidal recruitment/derecruitment which partly persists after its removal. The analysis of the intratidal volume-dependent C RS profiles could be used to guide intraoperative PEEP adjustments during elevated intraabdominal pressure.

  8. Measurement of tidal volume using respiratory ultrasonic plethysmography in anaesthetized, mechanically ventilated horses.

    PubMed

    Russold, Elena; Ambrisko, Tamas D; Schramel, Johannes P; Auer, Ulrike; Van Den Hoven, Rene; Moens, Yves P

    2013-01-01

    To compare tidal volume estimations obtained from Respiratory Ultrasonic Plethysmography (RUP) with simultaneous spirometric measurements in anaesthetized, mechanically ventilated horses. Prospective randomized experimental study. Five experimental horses. Five horses were anaesthetized twice (1 week apart) in random order in lateral and in dorsal recumbency. Nine ventilation modes (treatments) were scheduled in random order (each lasting 4 minutes) applying combinations of different tidal volumes (8, 10, 12 mL kg(-1)) and positive end-expiratory pressures (PEEP) (0, 10, 20 cm H(2)O). Baseline ventilation mode (tidal volume=15 mL kg(-1), PEEP=0 cm H(2)O) was applied for 4 minutes between all treatments. Spirometry and RUP data were downloaded to personal computers. Linear regression analyses (RUP versus spirometric tidal volume) were performed using different subsets of data. Additonally RUP was calibrated against spirometry using a regression equation for all RUP signal values (thoracic, abdominal and combined) with all data collectively and also by an individually determined best regression equation (highest R(2)) for each experiment (horse versus recumbency) separately. Agreement between methods was assessed with Bland-Altman analyses. The highest correlation of RUP and spirometric tidal volume (R(2)=0.81) was found with the combined RUP signal in horses in lateral recumbency and ventilated without PEEP. The bias ±2 SD was 0±2.66 L when RUP was calibrated for collective data, but decreased to 0±0.87 L when RUP was calibrated with individual data. A possible use of RUP for tidal volume measurement during IPPV needs individual calibration to obtain limits of agreement within ±20%. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  9. Impact of Extraperitoneal Dioxyde Carbon Insufflation on Respiratory Function in Anesthetized Adults: A Preliminary Study Using Electrical Impedance Tomography and Wash-out/Wash-in Technic

    PubMed Central

    Bordes, Julien; Mazzeo, Cecilia; Gourtobe, Philippe; Cungi, Pierre Julien; Antonini, Francois; Bourgoin, Stephane; Kaiser, Eric

    2015-01-01

    Background: Extraperitoneal laparoscopy has become a common technique for many surgical procedures, especially for inguinal hernia surgery. Investigations of physiological changes occurring during extraperitoneal carbon dioxide (CO2) insufflation mostly focused on blood gas changes. To date, the impact of extraperitoneal CO2 insufflation on respiratory mechanics remains unknown, whereas changes in respiratory mechanics have been extensively studied in intraperitoneal insufflation. Objectives: The aim of this study was to investigate the effects of extraperitoneal CO2 insufflation on respiratory mechanics. Patients and Methods: A prospective and observational study was performed on nine patients undergoing laparoscopic inguinal hernia repair. Anesthetic management and intraoperative care were standardized. All patients were mechanically ventilated with a tidal volume of 8 mL/kg using an Engström Carestation ventilator (GE Healthcare). Ventilation distribution was assessed by electrical impedance tomography (EIT). End-expiratory lung volume (EELV) was measured by a nitrogen wash-out/wash-in method. Ventilation distribution, EELV, ventilator pressures and hemodynamic parameters were assessed before extraperitoneal insufflation, and during insufflation with a PEEP of 0 cmH2O, 5 cmH20 and of 10 cmH20. Results: EELV and thoracopulmonary compliance were significantly decreased after extraperitoneal insufflation. Ventilation distribution was significantly higher in ventral lung regions during general anesthesia and was not modified after insufflation. A 10 cmH20 PEEP application resulted in a significant increase in EELV, and a shift of ventilation toward the dorsal lung regions. Conclusions: Extraperitoneal insufflation decreased EELV and thoracopulmonary compliance. Application of a 10 cmH20 PEEP increased EELV and homogenized ventilation distribution. This preliminary clinical study showed that extraperitoneal insufflation worsened respiratory mechanics, which may

  10. Assessing the Potential Use of Eye-Tracking Triangulation for Evaluating the Usability of an Online Diabetes Exercise System.

    PubMed

    Schaarup, Clara; Hartvigsen, Gunnar; Larsen, Lars Bo; Tan, Zheng-Hua; Årsand, Eirik; Hejlesen, Ole Kristian

    2015-01-01

    The Online Diabetes Exercise System was developed to motivate people with Type 2 diabetes to do a 25 minutes low-volume high-intensity interval training program. In a previous multi-method evaluation of the system, several usability issues were identified and corrected. Despite the thorough testing, it was unclear whether all usability problems had been identified using the multi-method evaluation. Our hypothesis was that adding the eye-tracking triangulation to the multi-method evaluation would increase the accuracy and completeness when testing the usability of the system. The study design was an Eye-tracking Triangulation; conventional eye-tracking with predefined tasks followed by The Post-Experience Eye-Tracked Protocol (PEEP). Six Areas of Interests were the basis for the PEEP-session. The eye-tracking triangulation gave objective and subjective results, which are believed to be highly relevant for designing, implementing, evaluating and optimizing systems in the field of health informatics. Future work should include testing the method on a larger and more representative group of users and apply the method on different system types.

  11. Respiratory mechanics in mechanically ventilated patients.

    PubMed

    Hess, Dean R

    2014-11-01

    Respiratory mechanics refers to the expression of lung function through measures of pressure and flow. From these measurements, a variety of derived indices can be determined, such as volume, compliance, resistance, and work of breathing. Plateau pressure is a measure of end-inspiratory distending pressure. It has become increasingly appreciated that end-inspiratory transpulmonary pressure (stress) might be a better indicator of the potential for lung injury than plateau pressure alone. This has resulted in a resurgence of interest in the use of esophageal manometry in mechanically ventilated patients. End-expiratory transpulmonary pressure might also be useful to guide the setting of PEEP to counterbalance the collapsing effects of the chest wall. The shape of the pressure-time curve might also be useful to guide the setting of PEEP (stress index). This has focused interest in the roles of stress and strain to assess the potential for lung injury during mechanical ventilation. This paper covers both basic and advanced respiratory mechanics during mechanical ventilation. Copyright © 2014 by Daedalus Enterprises.

  12. Effects of mechanical ventilation on gene expression profiles in renal allografts from brain dead rats.

    PubMed

    Hottenrott, Maximilia C; Krebs, Joerg; Pelosi, Paolo; Luecke, Thomas; Rocco, Patricia R M; Sticht, Carsten; Breedijk, Annette; Yard, Benito; Tsagogiorgas, Charalambos

    2017-12-01

    Pathophysiological changes of brain death (BD) are impairing distal organ function and harming potential renal allografts. Whether ventilation strategies influence the quality of renal allografts from BD donors has not been thoroughly studied. 28 adult male Wistar rats were randomly assigned to four groups: 1) no brain death (NBD) with low tidal volume/low positive endexpiratory pressure (PEEP) titrated to minimal static elastance of the respiratory system (LVT/OLPEEP); 2) NBD with high tidal volume/low PEEP (HVT/LPEEP); 3) brain death (BD) with LVT/OLPEEP; and 4) BD with HVT/LPEEP. We hypothesized that HVT/LPEEP in BD leads to increased interleukin 6 (IL-6) gene expression and impairs potential renal allografts after six hours of mechanical ventilation. We assessed inflammatory cytokines in serum, genome wide gene expression profiles and quantitative PCR (qPCR) in kidney tissue. The influence of BD on renal gene-expression profiles was greater than the influence of the ventilation strategy. In BD, LVT ventilation did not influence the inflammatory parameters or kidney function in our experimental model. Copyright © 2017. Published by Elsevier B.V.

  13. Measurement of lung volume in mechanically ventilated monkeys with an ultrasonic flow meter and the nitrogen washout method.

    PubMed

    Schibler, Andreas; Hammer, Jürg; Isler, Ruedi; Buess, Christian; Newth, Christopher J L

    2004-01-01

    Measurement of functional residual capacity (FRC) during mechanical ventilation is important to standardise respiratory system compliance and adjust the ventilator settings to optimise lung recruitment. In the present study we compared three methods to measure FRC. The bias flow nitrogen washout technique (FRC(N2MC)), the multiple breath nitrogen washout (FRC(MBNW)) and the multiple breath sulphur-hexafluoride washout using the molar mass signal of an ultrasonic flow meter (FRC(MBSF6)) were compared in six adult monkeys after endotracheal intubation and during spontaneous breathing and mechanical ventilation at three different positive end-expiratory pressure (PEEP) levels of 0, 5 and 10 cmH2O. Animal research laboratory. We found good agreement between all three methods and they all accurately measured changes in FRC when PEEP was increased. The coefficients of variance of the three measurement techniques were in the same range (1.3-9.2%). The measurement of the tracer gas concentration with the molar mass signal of the ultrasonic flow meter provides a good and simple alternative to respiratory mass spectrometer for FRC measurements in ventilated subjects.

  14. Plurilingual Ethos: A Peep into the Sociology of Language.

    ERIC Educational Resources Information Center

    Khubchandani, Lachman M.

    1998-01-01

    Issues in the study of bilingualism and multilingualism in India and Pakistan are examined, including the delineation of linguistic boundaries, defining a society that is multicultural and yet has developed a "communication ethos" based on a core of common experience, the difficulty in interpreting language role and defining language…

  15. Comparison of 2 correction methods for absolute values of esophageal pressure in subjects with acute hypoxemic respiratory failure, mechanically ventilated in the ICU.

    PubMed

    Guérin, Claude; Richard, Jean-Christophe

    2012-12-01

    A recent trial showed that setting PEEP according to end-expiratory transpulmonary pressure (P(pl,ee)) in acute lung injury/acute respiratory distress syndrome (ALI/ARDS) might improve patient outcome. P(pl,ee) was obtained by subtracting the absolute value of esophageal pressure (P(es)) from airway pressure an invariant value of 5 cm H(2)O. The goal of the present study was to compare 2 methods for correcting absolute P(es) values in terms of resulting P(pl,ee) and recommended PEEP. Measurements collected prospectively from 42 subjects with various forms of acute hypoxemic respiratory failure receiving mechanical ventilation in ICU were analyzed. P(es) was measured at PEEP (P(es,ee)) and at relaxation volume of the respiratory system Vr (P(es,Vr)), obtained by allowing the subject to exhale into the atmosphere (zero PEEP). Two methods for correcting P(es) were compared: Talmor method (P(pl,ee,Talmor) = P(es,ee) - 5 cm H(2)O), and Vr method (P(es,ee,Vr) = P(es,ee) - P(es,Vr)). The rationale was that P(es,Vr) was a more physiologically based correction factor than an invariant value of 5 cm H(2)O applied to all subjects. Over the 42 subjects, median and interquartile range of P(es,ee) and P(es,Vr) were 11 (7-14) cm H(2)O and 8 (4-11) cm H(2)O, respectively. P(pl,ee,Talmor) was 6 (1-8) cm H(2)O, and P(es,ee,Vr) was 2 (1-5) cm H(2)O (P = .008). Two groups of subjects were defined, based on the difference between the 2 corrected values. In 28 subjects P(pl,ee,Talmor) was ≥ P(es,ee,Vr) (7 [5-9] cm H(2)O vs 2 [1-5] cm H(2)O, respectively), while in 14 subjects P(es,ee,Vr) was > P(pl,ee,Talmor) (2 [0-4] cm H(2)O vs -1 [-3 to 2] cm H(2)O, respectively). P(pl,ee,Vr) was significantly greater than P(pl,ee,Talmor) (7 [5-11] cm H(2)O vs 5 [2-7] cm H(2)O) in the former, and significantly lower in the latter (1 [-2 to 6] cm H(2)O vs 6 [4-9] cm H(2)O). Referring absolute P(es) values to Vr rather than to an invariant value would be better adapted to a patient's physiological

  16. Assessing changes in the toxicity of effluents from intensive marine fish farms over time by using a battery of bioassays.

    PubMed

    Carballeira, Carlos; Cebro, Alesandra; Villares, Rubén; Carballeira, Alejo

    2018-05-01

    Although intensive marine fish farming is often assumed to be eco-friendly, the associated activity can lead to chronic exposure of marine organisms to potentially toxic discharges. Moreover, despite the increasing popularity of integrated multi-trophic aquaculture (IMTA), studies of the effects of fish farm effluents are almost non-existent. In the present study, the changes in the toxic potential of effluents from five land-based marine fish farms in NW Spain subjected for different lengths of time to a biodegradation procedure (for 0, 48, 120, and 240 h) were assessed in a battery of bioassays including organisms from different trophic levels (Vibrio fischeri, Isochrysis galbana, and Paracentrotus lividus). The results of the bioassays at the different times were then considered together with farm water flow in the Potential Ecotoxic Effects Probe (PEEP) index. Despite the high volumes of effluents discharged, the generally low toxicity of the effluents hinders assessment of potentially toxic effects. However, dose-response curves and statistical analysis demonstrated the existence of toxic effects during the first five days of the biodegradation procedure, especially immediately after sampling. The proposed modification of the PEEP index better reflects the changes in toxicity over time. Graphical abstract ᅟ.

  17. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.

    PubMed

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.

  18. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study* **

    PubMed Central

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653

  19. Time course of lung inflammatory and fibrogenic responses during protective mechanical ventilation in healthy rats.

    PubMed

    Krebs, Joerg; Pelosi, Paolo; Tsagogiorgas, Charalambos; Haas, Jenny; Yard, Benito; Rocco, Patricia R M; Luecke, Thomas

    2011-09-15

    This study aimed to assess pulmonary inflammatory and fibrogenic responses and their impact on lung mechanics and histology in healthy rats submitted to protective mechanical ventilation for different experimental periods. Eighteen Wistar rats were randomized to undergo open lung-mechanical ventilation (OL-MV) for 1, 6 or 12 h. Following a recruitment maneuver, a decremental PEEP trial was performed and PEEP set according to the minimal respiratory system static elastance. Respiratory system, lung, and chest-wall elastance and gas-exchange were maintained throughout the 12 h experimental period. Histological lung injury score remained low at 1 and 6 h, but was higher at 12 h due to overinflation. A moderate inflammatory response was observed with a distinct peak at 6h. Compared to unventilated controls, type I procollagen mRNA expression was decreased at 1 and 12h, while type III procollagen expression decreased throughout the 12h experimental period. In conclusion, OL-MV in healthy rats yielded overinflation after 6 h even though respiratory elastance and gas-exchange were preserved for up to 12 h. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Giving Reluctant Students a Voice

    ERIC Educational Resources Information Center

    Redekopp, Reynold; Bourbonniere, Elizabeth

    2009-01-01

    All teachers know them--the students who sit in the back of the room and never make a peep. If prodded, they may reluctantly offer a comment or opinion, but they are so obviously uncomfortable about participating that a teacher may wonder if it is even worth trying to engage them. Are they unprepared or just shy? Do they lack ideas or merely need…

  1. A Brief Review of the Adult Respiratory Distress Syndrome

    PubMed Central

    Hassan, Sheik N.; Hackney, Robert L.

    1982-01-01

    The adult respiratory distress syndrome (ARDS) is seen with increasing frequency. It is associated with a variety of conditions even in the absence of preexisting pulmonary diseases. The treatment often includes intubation, using positive-end expiratory pressure (PEEP), and other ancillary support. The mortality rate is high, and physicians caring for such patients should be on guard for disseminated intravascular coagulation, gastrointestinal hemorrhage, and infection. PMID:7120452

  2. Combination of Extracorporeal Life Support and Mesenchymal Stem Cell Therapy for Treatment of ARDS in Combat Casualties and Evacuation of Service Members with ARDS

    DTIC Science & Technology

    2017-10-01

    invasiveness of mechanical ventilation and inflammatory mediators as well as improvement in oxygenation and functional outcome. 4 Keywords Acute...The Clark system is allowing us to measure the mitochondrial activity by the oxygen consumption during activation. Because the LPS-induced injury we... Ventilation • Tidal Volume • Respiratory Rate • Peak inspiratory Pressure • Positive End Expiratory Pressure (PEEP) • Fraction of inspired oxygen

  3. Continuous positive airway pressure and ventilation are more effective with a nasal mask than a full face mask in unconscious subjects: a randomized controlled trial.

    PubMed

    Oto, Jun; Li, Qian; Kimball, William R; Wang, Jingping; Sabouri, Abdolnabi S; Harrell, Priscilla G; Kacmarek, Robert M; Jiang, Yandong

    2013-12-23

    Upper airway obstruction (UAO) is a major problem in unconscious subjects, making full face mask ventilation difficult. The mechanism of UAO in unconscious subjects shares many similarities with that of obstructive sleep apnea (OSA), especially the hypotonic upper airway seen during rapid eye movement sleep. Continuous positive airway pressure (CPAP) via nasal mask is more effective at maintaining airway patency than a full face mask in patients with OSA. We hypothesized that CPAP via nasal mask and ventilation (nCPAP) would be more effective than full face mask CPAP and ventilation (FmCPAP) for unconscious subjects, and we tested our hypothesis during induction of general anesthesia for elective surgery. In total, 73 adult subjects requiring general anesthesia were randomly assigned to one of four groups: nCPAP P0, nCPAP P5, FmCPAP P0, and FmCPAP P5, where P0 and P5 represent positive end-expiratory pressure (PEEP) 0 and 5 cm H2O applied prior to induction. After apnea, ventilation was initiated with pressure control ventilation at a peak inspiratory pressure over PEEP (PIP/PEEP) of 20/0, then 20/5, and finally 20/10 cm H2O, each applied for 1 min. At each pressure setting, expired tidal volume (Vte) was calculated by using a plethysmograph device. The rate of effective tidal volume (Vte > estimated anatomical dead space) was higher (87.9% vs. 21.9%; P<0.01) and the median Vte was larger (6.9 vs. 0 mL/kg; P<0.01) with nCPAP than with FmCPAP. Application of CPAP prior to induction of general anesthesia did not affect Vte in either approach (nCPAP pre- vs. post-; 7.9 vs. 5.8 mL/kg, P = 0.07) (FmCPAP pre- vs. post-; 0 vs. 0 mL/kg, P = 0.11). nCPAP produced more effective tidal volume than FmCPAP in unconscious subjects. ClinicalTrials.gov identifier: NCT01524614.

  4. Pulmonary atelectasis during low stretch ventilation: "open lung" versus "lung rest" strategy.

    PubMed

    Fanelli, Vito; Mascia, Luciana; Puntorieri, Valeria; Assenzio, Barbara; Elia, Vincenzo; Fornaro, Giancarlo; Martin, Erica L; Bosco, Martino; Delsedime, Luisa; Fiore, Tommaso; Grasso, Salvatore; Ranieri, V Marco

    2009-03-01

    Limiting tidal volume (VT) may minimize ventilator-induced lung injury (VILI). However, atelectasis induced by low VT ventilation may cause ultrastructural evidence of cell disruption. Apoptosis seems to be involved as protective mechanisms from VILI through the involvement of mitogen-activated protein kinases (MAPKs). We examined the hypothesis that atelectasis may influence the response to protective ventilation through MAPKs. Prospective randomized study. University animal laboratory. Adult male 129/Sv mice. Isolated, nonperfused lungs were randomized to VILI: VT of 20 mL/kg and positive end-expiratory pressure (PEEP) zero; low stretch/lung rest: VT of 6 mL/kg and 8-10 cm H2O of PEEP; low stretch/open lung: VT of 6 mL/kg, two recruitment maneuvers and 14-16 cm H2O of PEEP. Ventilator settings were adjusted using the stress index. Both low stretch strategies equally blunted the VILI-induced derangement of respiratory mechanics (static volume-pressure curve), lung histology (hematoxylin and eosin), and inflammatory mediators (interleukin-6, macrophage inflammatory protein-2 [enzyme-linked immunosorbent assay], and inhibitor of nuclear factor-kB[Western blot]). VILI caused nuclear swelling and membrane disruption of pulmonary cells (electron microscopy). Few pulmonary cells with chromatin condensation and fragmentation were seen during both low stretch strategies. However, although cell thickness during low stretch/open lung was uniform, low stretch/lung rest demonstrated thickening of epithelial cells and plasma membrane bleb formation. Compared with the low stretch/open lung, low stretch/lung rest caused a significant decrease in apoptotic cells (terminal deoxynucleotidyl transferase mediated deoxyuridine-triphosphatase nick end-labeling) and tissue expression of caspase-3 (Western blot). Both low stretch strategies attenuated the activation of MAPKs. Such reduction was larger during low stretch/open lung than during low stretch/lung rest (p < 0.001). Low stretch

  5. Feasibility of Protective Ventilation During Elective Supratentorial Neurosurgery: A Randomized, Crossover, Clinical Trial.

    PubMed

    Ruggieri, Francesco; Beretta, Luigi; Corno, Laura; Testa, Valentina; Martino, Enrico A; Gemma, Marco

    2017-06-30

    Traditional ventilation approaches, providing high tidal volumes (Vt), produce excessive alveolar distention and lung injury. Protective ventilation, employing lower Vt and positive end-expiratory pressure (PEEP), is an attractive alternative also for neuroanesthesia, when prolonged mechanical ventilation is needed. Nevertheless, protective ventilation during intracranial surgery may exert dangerous effects on intracranial pressure (ICP). We tested the feasibility of a protective ventilation strategy in neurosurgery. Our monocentric, double-blind, 1:1 randomized, 2×2 crossover study aimed at studying the effect size and variability of ICP in patients undergoing elective supratentorial brain tumor removal and alternatively ventilated with Vt 9 mL/kg-PEEP 0 mm Hg and Vt 7 mL/kg-PEEP 5 mm Hg. Respiratory rate was adjusted to maintain comparable end-tidal carbon dioxide between ventilation modes. ICP was measured through a subdural catheter inserted before dural opening. Forty patients were enrolled; 8 (15%) were excluded after enrollment. ICP did not differ between traditional and protective ventilation (11.28±5.37, 11 [7 to 14.5] vs. 11.90±5.86, 11 [8 to 15] mm Hg; P=0.541). End-tidal carbon dioxide (28.91±2.28, 29 [28 to 30] vs. 28.00±2.17, 28 [27 to 29] mm Hg; P<0.001). Peak airway pressure (17.25±1.97, 17 [16 to 18.5] vs. 15.81±2.87, 15.5 [14 to 17] mm Hg; P<0.001) and plateau airway pressure (16.06±2.30, 16 [14.5 to 17] vs. 14.19±2.82, 14 [12.5 to 16] mm Hg; P<0.001) were higher during protective ventilation. Blood pressure, heart rate, and body temperature did not differ between ventilation modes. Dural tension was "acceptable for surgery" in all cases. ICP differences between ventilation modes were not affected by ICP values under traditional ventilation (coefficient=0.067; 95% confidence interval, -0.278 to 0.144; P=0.523). Protective ventilation is a feasible alternative to traditional ventilation during elective neurosurgery.

  6. Modes of mechanical ventilation for the operating room.

    PubMed

    Ball, Lorenzo; Dameri, Maddalena; Pelosi, Paolo

    2015-09-01

    Most patients undergoing surgical procedures need to be mechanically ventilated, because of the impact of several drugs administered at induction and during maintenance of general anaesthesia on respiratory function. Optimization of intraoperative mechanical ventilation can reduce the incidence of post-operative pulmonary complications and improve the patient's outcome. Preoxygenation at induction of general anaesthesia prolongs the time window for safe intubation, reducing the risk of hypoxia and overweighs the potential risk of reabsorption atelectasis. Non-invasive positive pressure ventilation delivered through different interfaces should be considered at the induction of anaesthesia morbidly obese patients. Anaesthesia ventilators are becoming increasingly sophisticated, integrating many functions that were once exclusive to intensive care. Modern anaesthesia machines provide high performances in delivering the desired volumes and pressures accurately and precisely, including assisted ventilation modes. Therefore, the physicians should be familiar with the potential and pitfalls of the most commonly used intraoperative ventilation modes: volume-controlled, pressure-controlled, dual-controlled and assisted ventilation. Although there is no clear evidence to support the advantage of any one of these ventilation modes over the others, protective mechanical ventilation with low tidal volume and low levels of positive end-expiratory pressure (PEEP) should be considered in patients undergoing surgery. The target tidal volume should be calculated based on the predicted or ideal body weight rather than on the actual body weight. To optimize ventilation monitoring, anaesthesia machines should include end-inspiratory and end-expiratory pause as well as flow-volume loop curves. The routine administration of high PEEP levels should be avoided, as this may lead to haemodynamic impairment and fluid overload. Higher PEEP might be considered during surgery longer than 3 h

  7. Evaluating the effects of protective ventilation on organ-specific cytokine production in porcine experimental postoperative sepsis.

    PubMed

    Sperber, Jesper; Lipcsey, Miklós; Larsson, Anders; Larsson, Anders; Sjölin, Jan; Castegren, Markus

    2015-05-10

    Protective ventilation with lower tidal volume (VT) and higher positive end-expiratory pressure (PEEP) reduces the negative additive effects of mechanical ventilation during systemic inflammatory response syndrome. We hypothesised that protective ventilation during surgery would affect the organ-specific immune response in an experimental animal model of endotoxin-induced sepsis-like syndrome. 30 pigs were laparotomised for 2 hours (h), after which a continuous endotoxin infusion was started at 0.25 micrograms × kg(-1) × h(-1) for 5 h. Catheters were placed in the carotid artery, hepatic vein, portal vein and jugular bulb. Animals were randomised to two protective ventilation groups (n = 10 each): one group was ventilated with VT 6 mL × kg(-1) during the whole experiment while the other group was ventilated during the surgical phase with VT of 10 mL × kg(-1). In both groups PEEP was 5 cmH2O during surgery and increased to 10 cmH2O at the start of endotoxin infusion. A control group (n = 10) was ventilated with VT of 10 mL × kg(-1) and PEEP 5 cm H20 throughout the experiment. In four sample locations we a) simultaneously compared cytokine levels, b) studied the effect of protective ventilation initiated before and during endotoxemia and c) evaluated protective ventilation on organ-specific cytokine levels. TNF-alpha levels were highest in the hepatic vein, IL-6 levels highest in the artery and jugular bulb and IL-10 levels lowest in the artery. Protective ventilation initiated before and during endotoxemia did not differ in organ-specific cytokine levels. Protective ventilation led to lower levels of TNF-alpha in the hepatic vein compared with the control group, whereas no significant differences were seen in the artery, portal vein or jugular bulb. Variation between organs in cytokine output was observed during experimental sepsis. We see no implication from cytokine levels for initiating protective ventilation before endotoxemia. However, during endotoxemia

  8. Intraoperative protective mechanical ventilation and risk of postoperative respiratory complications: hospital based registry study.

    PubMed

    Ladha, Karim; Vidal Melo, Marcos F; McLean, Duncan J; Wanderer, Jonathan P; Grabitz, Stephanie D; Kurth, Tobias; Eikermann, Matthias

    2015-07-14

    To evaluate the effects of intraoperative protective ventilation on major postoperative respiratory complications and to define safe intraoperative mechanical ventilator settings that do not translate into an increased risk of postoperative respiratory complications. Hospital based registry study. Academic tertiary care hospital and two affiliated community hospitals in Massachusetts, United States. 69,265 consecutively enrolled patients over the age of 18 who underwent a non-cardiac surgical procedure between January 2007 and August 2014 and required general anesthesia with endotracheal intubation. Protective ventilation, defined as a median positive end expiratory pressure (PEEP) of 5 cmH2O or more, a median tidal volume of less than 10 mL/kg of predicted body weight, and a median plateau pressure of less than 30 cmH2O. Composite outcome of major respiratory complications, including pulmonary edema, respiratory failure, pneumonia, and re-intubation. Of the 69,265 enrolled patients 34,800 (50.2%) received protective ventilation and 34,465 (49.8%) received non-protective ventilation intraoperatively. Protective ventilation was associated with a decreased risk of postoperative respiratory complications in multivariable regression (adjusted odds ratio 0.90, 95% confidence interval 0.82 to 0.98, P=0.013). The results were similar in the propensity score matched cohort (odds ratio 0.89, 95% confidence interval 0.83 to 0.97, P=0.004). A PEEP of 5 cmH2O and median plateau pressures of 16 cmH2O or less were associated with the lowest risk of postoperative respiratory complications. Intraoperative protective ventilation was associated with a decreased risk of postoperative respiratory complications. A PEEP of 5 cmH2O and a plateau pressure of 16 cmH2O or less were identified as protective mechanical ventilator settings. These findings suggest that protective thresholds differ for intraoperative ventilation in patients with normal lungs compared with those used for patients

  9. Epidemiology, practice of ventilation and outcome for patients at increased risk of postoperative pulmonary complications: LAS VEGAS - an observational study in 29 countries.

    PubMed

    2017-08-01

    Limited information exists about the epidemiology and outcome of surgical patients at increased risk of postoperative pulmonary complications (PPCs), and how intraoperative ventilation was managed in these patients. To determine the incidence of surgical patients at increased risk of PPCs, and to compare the intraoperative ventilation management and postoperative outcomes with patients at low risk of PPCs. This was a prospective international 1-week observational study using the 'Assess Respiratory Risk in Surgical Patients in Catalonia risk score' (ARISCAT score) for PPC for risk stratification. Adult patients requiring intraoperative ventilation during general anaesthesia for surgery in 146 hospitals across 29 countries. The primary outcome was the incidence of patients at increased risk of PPCs based on the ARISCAT score. Secondary outcomes included intraoperative ventilatory management and clinical outcomes. A total of 9864 patients fulfilled the inclusion criteria. The incidence of patients at increased risk was 28.4%. The most frequently chosen tidal volume (VT) size was 500 ml, or 7 to 9 ml kg predicted body weight, slightly lower in patients at increased risk of PPCs. Levels of positive end-expiratory pressure (PEEP) were slightly higher in patients at increased risk of PPCs, with 14.3% receiving more than 5 cmH2O PEEP compared with 7.6% in patients at low risk of PPCs (P < 0.001). Patients with a predicted preoperative increased risk of PPCs developed PPCs more frequently: 19 versus 7%, relative risk (RR) 3.16 (95% confidence interval 2.76 to 3.61), P < 0.001) and had longer hospital stays. The only ventilatory factor associated with the occurrence of PPCs was the peak pressure. The incidence of patients with a predicted increased risk of PPCs is high. A large proportion of patients receive high VT and low PEEP levels. PPCs occur frequently in patients at increased risk, with worse clinical outcome. The study was registered at Clinicaltrials

  10. Inhaled nitric oxide in acute respiratory distress syndrome with and without septic shock requiring norepinephrine administration: a dose–response study

    PubMed Central

    Mourgeon, Eric; Puybasset, Louis; Law-Koune, Jean-Dominique; Lu, Qin; Abdennour, Lamine; Gallart, Lluis; Malassine, Patrick; Rao, GS Umamaheswara; Cluzel, Philippe; Bennani, Abdelhai; Coriat, Pierre; Rouby, Jean-Jacques

    1997-01-01

    Background: The aim of this prospective study was to assess whether the presence of septic shock could influence the dose response to inhaled nitric oxide (NO) in NO-responding patients with adult respiratory distress syndrome (ARDS). Results: Eight patients with ARDS and without septic shock (PaO2 = 95 ± 16 mmHg, PEEP = 0, FiO2 = 1.0), and eight patients with ARDS and septic shock (PaO2 = 88 ± 11 mmHg, PEEP = 0, FiO2 = 1.0) receiving exclusively norepinephrine were studied. All responded to 15 ppm inhaled NO with an increase in PaO2 of at least 40 mmHg, at FiO2 1.0 and PEEP 10 cmH2O. Inspiratory intratracheal NO concentrations were recorded continuously using a fast response time chemiluminescence apparatus. Seven inspiratory NO concentrations were randomly administered: 0.15, 0.45, 1.5, 4.5, 15, 45 and 150 ppm. In both groups, NO induced a dose-dependent decrease in mean pulmonary artery pressure (MPAP), pulmonary vascular resistance index (PVRI), and venous admixture (QVA/QT), and a dose-dependent increase in PaO2/FiO2 (P ≤ 0.012). Dose-response of MPAP and PVRI were similar in both groups with a plateau effect at 4.5 ppm. Dose-response of PaO2/FiO2 was influenced by the presence of septic shock. No plateau effect was observed in patients with septic shock and PaO2/FiO2 increased by 173 ± 37% at 150 ppm. In patients without septic shock, an 82 ± 26% increase in PaO2/FiO2 was observed with a plateau effect obtained at 15 ppm. In both groups, dose-response curves demonstrated a marked interindividual variability and in five patients pulmonary vascular effect and improvement in arterial oxygenation were dissociated. Conclusion: For similar NOinduced decreases in MPAP and PVRI in both groups, the increase in arterial oxygenation was more marked in patients with septic shock. PMID:11056694

  11. Early identification of patients at risk for acute respiratory distress syndrome among severe pneumonia: a retrospective cohort study

    PubMed Central

    Luo, Jian; Yu, He; Hu, Yue-Hong; Liu, Dan; Wang, Yi-Wei; Wang, Mao-Yun

    2017-01-01

    Background Severe pneumonia is the predominant cause for acute respiratory distress syndrome (ARDS). Identification of ARDS from patients with severe pneumonia remains a significant clinical problem due to the overlap of clinical presentations and symptoms. Early recognition of risks for ARDS from severe pneumonia is of great clinical value. Methods From April 2014 to December 2015, patients with severe pneumonia at admission were retrieved from the hospital database, of which ARDS developed within 7 days were further identified. We compared the demographic and clinical characteristics at admission between severe pneumonia patients with and without ARDS development, followed by analysis of potential predictors for ARDS development and mortality. Multivariate logistic regression and receiver operating characteristic (ROC) curves were performed to screen independent risk factors and identify their sensitivity in predicting ARDS development and prognosis. Results Compared with severe pneumonia without ARDS development, patients with ARDS development had shorter disease duration before admission, higher lung injury score (LIS), serum fibrinogen (FiB), and positive end-expiratory pressure (PEEP), lower Marshall score, sequential organ failure assessment score and proportion of cardiovascular and gastrointestinal diseases, but similar mortality. Serum FiB >5.15 g/L [adjusted odds ratio (OR) 1.893, 95% confidence interval (CI): 1.141–3.142, P=0.014] and PEEP >6.5 cmH2O (adjusted OR 1.651, 95% CI: 1.218–2.237, P=0.001) were independent predictors for ARDS development with a sensitivity of 58.3% and 87.5%, respectively, and pH <7.35 (adjusted OR 0.832, 95% CI: 0.702–0.985, P=0.033) was an independent risk factor for ARDS mortality with a sensitivity of 95.2%. Conclusions ARDS development risk could be early recognized by PEEP >6.5 cmH2O and serum FiB >5.15 g/L in severe pneumonia patients, and pH <7.35 is a reliable prognostic factor in predicting ARDS mortality risk

  12. Driving pressure and survival in the acute respiratory distress syndrome.

    PubMed

    Amato, Marcelo B P; Meade, Maureen O; Slutsky, Arthur S; Brochard, Laurent; Costa, Eduardo L V; Schoenfeld, David A; Stewart, Thomas E; Briel, Matthias; Talmor, Daniel; Mercat, Alain; Richard, Jean-Christophe M; Carvalho, Carlos R R; Brower, Roy G

    2015-02-19

    Mechanical-ventilation strategies that use lower end-inspiratory (plateau) airway pressures, lower tidal volumes (VT), and higher positive end-expiratory pressures (PEEPs) can improve survival in patients with the acute respiratory distress syndrome (ARDS), but the relative importance of each of these components is uncertain. Because respiratory-system compliance (CRS) is strongly related to the volume of aerated remaining functional lung during disease (termed functional lung size), we hypothesized that driving pressure (ΔP=VT/CRS), in which VT is intrinsically normalized to functional lung size (instead of predicted lung size in healthy persons), would be an index more strongly associated with survival than VT or PEEP in patients who are not actively breathing. Using a statistical tool known as multilevel mediation analysis to analyze individual data from 3562 patients with ARDS enrolled in nine previously reported randomized trials, we examined ΔP as an independent variable associated with survival. In the mediation analysis, we estimated the isolated effects of changes in ΔP resulting from randomized ventilator settings while minimizing confounding due to the baseline severity of lung disease. Among ventilation variables, ΔP was most strongly associated with survival. A 1-SD increment in ΔP (approximately 7 cm of water) was associated with increased mortality (relative risk, 1.41; 95% confidence interval [CI], 1.31 to 1.51; P<0.001), even in patients receiving "protective" plateau pressures and VT (relative risk, 1.36; 95% CI, 1.17 to 1.58; P<0.001). Individual changes in VT or PEEP after randomization were not independently associated with survival; they were associated only if they were among the changes that led to reductions in ΔP (mediation effects of ΔP, P=0.004 and P=0.001, respectively). We found that ΔP was the ventilation variable that best stratified risk. Decreases in ΔP owing to changes in ventilator settings were strongly associated with

  13. Application of mid-frequency ventilation in an animal model of lung injury: a pilot study.

    PubMed

    Mireles-Cabodevila, Eduardo; Chatburn, Robert L; Thurman, Tracy L; Zabala, Luis M; Holt, Shirley J; Swearingen, Christopher J; Heulitt, Mark J

    2014-11-01

    Mid-frequency ventilation (MFV) is a mode of pressure control ventilation based on an optimal targeting scheme that maximizes alveolar ventilation and minimizes tidal volume (VT). This study was designed to compare the effects of conventional mechanical ventilation using a lung-protective strategy with MFV in a porcine model of lung injury. Our hypothesis was that MFV can maximize ventilation at higher frequencies without adverse consequences. We compared ventilation and hemodynamic outcomes between conventional ventilation and MFV. This was a prospective study of 6 live Yorkshire pigs (10 ± 0.5 kg). The animals were subjected to lung injury induced by saline lavage and injurious conventional mechanical ventilation. Baseline conventional pressure control continuous mandatory ventilation was applied with V(T) = 6 mL/kg and PEEP determined using a decremental PEEP trial. A manual decision support algorithm was used to implement MFV using the same conventional ventilator. We measured P(aCO2), P(aO2), end-tidal carbon dioxide, cardiac output, arterial and venous blood oxygen saturation, pulmonary and systemic vascular pressures, and lactic acid. The MFV algorithm produced the same minute ventilation as conventional ventilation but with lower V(T) (-1 ± 0.7 mL/kg) and higher frequency (32.1 ± 6.8 vs 55.7 ± 15.8 breaths/min, P < .002). There were no differences between conventional ventilation and MFV for mean airway pressures (16.1 ± 1.3 vs 16.4 ± 2 cm H2O, P = .75) even when auto-PEEP was higher (0.6 ± 0.9 vs 2.4 ± 1.1 cm H2O, P = .02). There were no significant differences in any hemodynamic measurements, although heart rate was higher during MFV. In this pilot study, we demonstrate that MFV allows the use of higher breathing frequencies and lower V(T) than conventional ventilation to maximize alveolar ventilation. We describe the ventilatory or hemodynamic effects of MFV. We also demonstrate that the application of a decision support algorithm to manage MFV

  14. ``Peeps,'' cream, heads, and food coloring in a vacuum jar

    NASA Astrophysics Data System (ADS)

    DePino, Andrew

    2001-01-01

    This note describes some methods of adding interest to the standard vacuum jar demonstrations. Marshmallow animals, shaving cream, doll heads, and food coloring add some spark to these demos. These new twists have been well received by the students.

  15. "Scientific peep show": the human body in contemporary science museums.

    PubMed

    Canadelli, Elena

    2011-01-01

    The essay focuses on the discourse about the human body developed by contemporary science museums with educational and instructive purposes directed at the general public. These museums aim mostly at mediating concepts such as health and prevention. The current scenario is linked with two examples of past museums: the popular anatomical museums which emerged during the 19th century and the health museums thrived between 1910 and 1940. On the museological path about the human body self-care we went from the emotionally involving anatomical Venuses to the inexpressive Transparent Man, from anatomical specimens of ill organs and deformed subjects to the mechanical and electronic models of the healthy body. Today the body is made transparent by the new medical diagnostics and by the latest discoveries of endoscopy. The way museums and science centers presently display the human body involves computers, 3D animation, digital technologies, hands-on models of large size human parts.

  16. Cardio-Pulmonary Response to Shock.

    DTIC Science & Technology

    1983-09-30

    attenuated by inhibition of Tx synthesis . These data indicate that the prostanoids exert direct and indirect acticns in moderating c function...identified as the circulating negative inotropic agent whose production is stimulated by PG synthesis during PEEP. - The large amount of prostacyclin...127 ml - in controls (p < 0.05). The importance of WBC Tx synthesis in the induction of permeability was tested by stimulating isolated WBC with the

  17. Postflight hardware evaluation 360T026 (RSRM-26, STS-47)

    NASA Technical Reports Server (NTRS)

    Nielson, Greg

    1993-01-01

    The final report for the Clearfield disassembly evaluation and a continuation of the KSC postflight assessment for the 360T026 (STS-47) Redesigned Solid Rocket Motor (RSRM) flight set is provided. All observed hardware conditions were documented on PFOR's and are included in Appendices A, B, and C. Appendices D and E contain the measurements and safety factor data for the nozzle and insulation components. This report, along with the KSC Ten-Day Postflight Hardware Evaluation Report (TWR-64203), represents a summary of the 360T026 hardware evaluation. The as-flown hardware configuration is documented in TWR-60472. Disassembly evaluation photograph numbers are logged in TWA-1987. The 360T026 flight set disassembly evaluations described were performed at the RSRM Refurbishment Facility in Clearfield, Utah. The final factory joint demate occurred on 12 April 1993. Detailed evaluations were performed in accordance with the Clearfield Postflight Engineering Evaluation Plan (PEEP), TWR-50051, Revision A. All observations were compared against limits that are also defined in the PEEP. These limits outline the criteria for categorizing the observations as acceptable, reportable, or critical. Hardware conditions that were unexpected and/or determined to be reportable or critical were evaluated by the applicable CPT and tracked through the PFAR system.

  18. Association between ventilatory settings and development of acute respiratory distress syndrome in mechanically ventilated patients due to brain injury.

    PubMed

    Tejerina, Eva; Pelosi, Paolo; Muriel, Alfonso; Peñuelas, Oscar; Sutherasan, Yuda; Frutos-Vivar, Fernando; Nin, Nicolás; Davies, Andrew R; Rios, Fernando; Violi, Damian A; Raymondos, Konstantinos; Hurtado, Javier; González, Marco; Du, Bin; Amin, Pravin; Maggiore, Salvatore M; Thille, Arnaud W; Soares, Marco Antonio; Jibaja, Manuel; Villagomez, Asisclo J; Kuiper, Michael A; Koh, Younsuck; Moreno, Rui P; Zeggwagh, Amine Ali; Matamis, Dimitrios; Anzueto, Antonio; Ferguson, Niall D; Esteban, Andrés

    2017-04-01

    In neurologically critically ill patients with mechanical ventilation (MV), the development of acute respiratory distress syndrome (ARDS) is a major contributor to morbidity and mortality, but the role of ventilatory management has been scarcely evaluated. We evaluate the association of tidal volume, level of PEEP and driving pressure with the development of ARDS in a population of patients with brain injury. We performed a secondary analysis of a prospective, observational study on mechanical ventilation. We included 986 patients mechanically ventilated due to an acute brain injury (hemorrhagic stroke, ischemic stroke or brain trauma). Incidence of ARDS in this cohort was 3%. Multivariate analysis suggested that driving pressure could be associated with the development of ARDS (odds ratio for unit increment of driving pressure 1.12; confidence interval for 95%: 1.01 to 1.23) whereas we did not observe association for tidal volume (in ml per kg of predicted body weight) or level of PEEP. ARDS was associated with an increase in mortality, longer duration of mechanical ventilation, and longer ICU length of stay. In a cohort of brain-injured patients the development of ARDS was not common. Driving pressure was associated with the development of this disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Cardiopulmonary Laboratory AFSC 904X0

    DTIC Science & Technology

    1990-10-01

    SET UP POSITIVE END EXPIRATORY PRESSURE (PEEP) DEVICES 100 J321 SET UP CONTINUOUS POSITIVE AIRWAY PRESSURE ( CPAP ) DEVICES 100 J298 ASSIST PHYSICIAN IN...PRESSURE VENTILATORS 61 COMPUTERIZED PULMONARY FUNCTION ANALYZERS 61 TREADMILLS 59 HOLTER MONITOR EQUIPMENT 57 CPAP EQUIPMENT 54 PRESSURE REGULATORS 48...SUCTIONING PROCEDURES 95 J321 SET UP CONTINUOUS POSITIVE AIRWAY PRESSURE ( CPAP ) DEVICES 95 J332 SET UP VOLUME VENTILATORS 93 F148 PERFORM ARTERIAL PUNCTURES 93

  20. Non-lobar atelectasis generates inflammation and structural alveolar injury in the surrounding healthy tissue during mechanical ventilation.

    PubMed

    Retamal, Jaime; Bergamini, Bruno Curty; Carvalho, Alysson R; Bozza, Fernando A; Borzone, Gisella; Borges, João Batista; Larsson, Anders; Hedenstierna, Göran; Bugedo, Guillermo; Bruhn, Alejandro

    2014-09-09

    When alveoli collapse the traction forces exerted on their walls by adjacent expanded units may increase and concentrate. These forces may promote its re-expansion at the expense of potentially injurious stresses at the interface between the collapsed and the expanded units. We developed an experimental model to test the hypothesis that a local non-lobar atelectasis can act as a stress concentrator, contributing to inflammation and structural alveolar injury in the surrounding healthy lung tissue during mechanical ventilation. A total of 35 rats were anesthetized, paralyzed and mechanically ventilated. Atelectasis was induced by bronchial blocking: after five minutes of stabilization and pre-oxygenation with FIO2 = 1.0, a silicon cylinder blocker was wedged in the terminal bronchial tree. Afterwards, the animals were randomized between two groups: 1) Tidal volume (VT) = 10 ml/kg and positive end-expiratory pressure (PEEP) = 3 cmH2O (VT10/PEEP3); and 2) VT = 20 ml/kg and PEEP = 0 cmH2O (VT20/zero end-expiratory pressure (ZEEP)). The animals were then ventilated during 180 minutes. Three series of experiments were performed: histological (n = 12); tissue cytokines (n = 12); and micro-computed tomography (microCT; n = 2). An additional six, non-ventilated, healthy animals were used as controls. Atelectasis was successfully induced in the basal region of the lung of 26 out of 29 animals. The microCT of two animals revealed that the volume of the atelectasis was 0.12 and 0.21 cm3. There were more alveolar disruption and neutrophilic infiltration in the peri-atelectasis region than the corresponding contralateral lung (control) in both groups. Edema was higher in the peri-atelectasis region than the corresponding contralateral lung (control) in the VT20/ZEEP than VT10/PEEP3 group. The volume-to-surface ratio was higher in the peri-atelectasis region than the corresponding contralateral lung (control) in both groups. We did not find statistical

  1. Application of intraoperative lung-protective ventilation varies in accordance with the knowledge of anaesthesiologists: a single-Centre questionnaire study and a retrospective observational study.

    PubMed

    Kim, Seung Hyun; Na, Sungwon; Lee, Woo Kyung; Choi, Hyunwoo; Kim, Jeongmin

    2018-04-02

    The benefits of lung-protective ventilation (LPV) with a low tidal volume (6 mL/kg of ideal body weight [IBW]), limited plateau pressure (< 28-30 cm H 2 O), and appropriate positive end-expiratory pressure (PEEP) in patients with acute respiratory distress syndrome have become apparent and it is now widely adopted in intensive care units. Recently evidence for LPV in general anaesthesia has been accumulated, but it is not yet generally applied by anaesthesiologists in the operating room. This study investigated the perception about intraoperative LPV among 82 anaesthesiologists through a questionnaire survey and identified the differences in ventilator settings according to recognition of lung-protective ventilation. Furthermore, we investigated the changes in the trend for using this form of ventilation during general anaesthesia in the past 10 years. Anaesthesiologists who had received training in LPV were more knowledgeable about this approach. Anaesthesiologists with knowledge of the concept behind LPV strategies applied a lower tidal volume (median (IQR [range]), 8.2 (8.0-9.2 [7.1-10.3]) vs. 9.2 (9.1-10.1 [7.6-10.1]) mL/kg; p = 0.033) and used PEEP more frequently (69/72 [95.8%] vs. 5/8 [62.5%]; p = 0.012; odds ratio, 13.8 [2.19-86.9]) for laparoscopic surgery than did those without such knowledge. Anaesthesiologists who were able to answer a question related to LPV correctly (respondents who chose 'height' to a multiple choice question asking what variables should be considered most important in the initial setting of tidal volume) applied a lower tidal volume in cases of laparoscopic surgery and obese patients. There was an increase in the number of patients receiving LPV (V T  < 10 mL/kgIBW and PEEP ≥5 cm H 2 O) between 2004 and 2014 (0/818 [0.0%] vs. 280/818 [34.2%]; p <  0.001). Our study suggests that the knowledge of LPV is directly related to its implementation, and can explain the increase in LPV use in general anaesthesia

  2. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.

    PubMed

    Chenelle, Christopher T; Itagaki, Taiga; Fisher, Daniel F; Berra, Lorenzo; Kacmarek, Robert M

    2017-01-01

    Cuff design affects microaspiration, a risk factor for pneumonia. We questioned whether the PneuX low-volume fold-free cuff design would prevent cuff leakage and maintain the same tracheal wall pressure as high-volume, low-pressure (HVLP) cuffs. We evaluated 4 HVLP-cuffed endotracheal tubes (ETTs), Hi-Lo (polyvinyl chloride [PVC]), Microcuff (polyurethane [PU]), SealGuard (PU + tapered), and TaperGuard (PVC + tapered), and the PneuX with its dedicated tracheal seal monitor. In Part 1, we determined tracheal wall pressure using each cuff's capacity to support water columns across recommended intracuff pressures. In Part 2, we evaluated the tracheal seal monitor function at recommended settings. In Part 3, we compared leakage volumes of all ETTs during 30 min of simulated mechanical ventilation or during 8 h if no leak occurred. Parts 1 and 3 were performed with/without lubrication and PEEP. In Part 1, PneuX cuffs exerted an average tracheal wall pressure of 27.4 ± 2.4 cm H 2 O at the recommended intracuff pressure of approximately 80 cm H 2 O. Tracheal wall pressure did not differ among HVLP cuffs (19.6 ± 1.4 to 29.5 ± 1.4 cm H 2 O). In Part 2, preinflation intracuff pressure affected the time to obtain tracheal seal monitor pressure attainment (P < .01). The tracheal seal monitor generated average calculated tracheal wall pressure of 33.4 ± 1.2 cm H 2 O. In Part 3, PneuX ETT showed no leak across 8 h for all trials. Overall, leakage volume was lower with PU (P < .01) and PneuX (P < .01) than with PVC cuffs, regardless of shape, and lower with lubrication and/or PEEP (all P < .01). In each HVLP cuff, lubrication alone eliminated leak at an intracuff pressure of ≤30 cm H 2 O. The PneuX cuff generally exerted acceptable tracheal wall pressure, but the tracheal wall pressure monitor allowed pressures exceeding 30 cm H 2 O in some trials and was the only ETT to prevent leak in all tests. For HVLP cuffs, leak was reduced by PU and PEEP and eliminated by lubrication

  3. From the Secondary Section: Mentoring New Teachers by Empowering the "Peeps"

    ERIC Educational Resources Information Center

    Haas, Kay Parks

    2012-01-01

    If the author was to pinpoint her greatest passion as an educator, it would be that of mentoring teachers. Everyone knows the statistics of how many new teachers leave the profession after just a few years and that one of the factors in retaining them lies in the value of a quality mentor. Looking back, the author realizes that educators' first…

  4. Associations between ventilator settings during extracorporeal membrane oxygenation for refractory hypoxemia and outcome in patients with acute respiratory distress syndrome: a pooled individual patient data analysis : Mechanical ventilation during ECMO.

    PubMed

    Serpa Neto, Ary; Schmidt, Matthieu; Azevedo, Luciano C P; Bein, Thomas; Brochard, Laurent; Beutel, Gernot; Combes, Alain; Costa, Eduardo L V; Hodgson, Carol; Lindskov, Christian; Lubnow, Matthias; Lueck, Catherina; Michaels, Andrew J; Paiva, Jose-Artur; Park, Marcelo; Pesenti, Antonio; Pham, Tài; Quintel, Michael; Marco Ranieri, V; Ried, Michael; Roncon-Albuquerque, Roberto; Slutsky, Arthur S; Takeda, Shinhiro; Terragni, Pier Paolo; Vejen, Marie; Weber-Carstens, Steffen; Welte, Tobias; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2016-11-01

    Extracorporeal membrane oxygenation (ECMO) is a rescue therapy for patients with acute respiratory distress syndrome (ARDS). The aim of this study was to evaluate associations between ventilatory settings during ECMO for refractory hypoxemia and outcome in ARDS patients. In this individual patient data meta-analysis of observational studies in adult ARDS patients receiving ECMO for refractory hypoxemia, a time-dependent frailty model was used to determine which ventilator settings in the first 3 days of ECMO had an independent association with in-hospital mortality. Nine studies including 545 patients were included. Initiation of ECMO was accompanied by significant decreases in tidal volume size, positive end-expiratory pressure (PEEP), plateau pressure, and driving pressure (plateau pressure - PEEP) levels, and respiratory rate and minute ventilation, and resulted in higher PaO 2 /FiO 2 , higher arterial pH and lower PaCO 2 levels. Higher age, male gender and lower body mass index were independently associated with mortality. Driving pressure was the only ventilatory parameter during ECMO that showed an independent association with in-hospital mortality [adjusted HR, 1.06 (95 % CI, 1.03-1.10)]. In this series of ARDS patients receiving ECMO for refractory hypoxemia, driving pressure during ECMO was the only ventilator setting that showed an independent association with in-hospital mortality.

  5. Intra-aortic balloon pump combined with mechanical ventilation for treating patients aged > 60 years in cardiogenic shock: Retrospective analysis

    PubMed Central

    Liu, Hongwei; Wu, Xueping; Zhao, Xiaoning; Zhu, Ping

    2016-01-01

    Objective To examine if mechanical ventilation with positive end-expiratory pressure (PEEP) combined with intra-aortic balloon pump (IABP) provided a better outcome than IABP alone for the treatment of cardiogenic shock after acute myocardial infarction in patients aged > 60 years. Methods This was a retrospective analysis of data from patients in cardiogenic shock, refractory to pharmacological therapy and treated at a geriatric coronary care unit. Results Sixty-two patients were eligible for study inclusion: 33 received IABP alone; 29 received IABP combined with mechanical ventilation. Patients in the IABP + mechanical ventilation group had lower mean arterial blood pressure (BP), systolic BP and partial pressure of oxygen compared with the IABP group, indicating worse cardiac and pulmonary function. In addition, higher rates of pulmonary infection and renal insufficiency were observed in the IABP + mechanical ventilation group than in the IABP group. A statistically significant improvement of left ventricular function before and after treatment was observed in the IABP + mechanical ventilation group, but not in the IABP group. Pulmonary infection and renal insufficiency were risk factors for all-cause in-hospital mortality; successful revascularization was a negative risk factor. There was no between-group difference in survival. Conclusion Mechanical ventilation with an appropriate level of PEEP appears to enhance the beneficial effects of IABP on left ventricular function for patients in cardiogenic shock. PMID:27020597

  6. The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management.

    PubMed

    Szlavecz, Akos; Chiew, Yeong Shiong; Redmond, Daniel; Beatson, Alex; Glassenbury, Daniel; Corbett, Simon; Major, Vincent; Pretty, Christopher; Shaw, Geoffrey M; Benyo, Balazs; Desaive, Thomas; Chase, J Geoffrey

    2014-09-30

    Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. Using CURE Soft, patient's respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient's respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes.

  7. Effects of vertical positioning on gas exchange and lung volumes in acute respiratory distress syndrome.

    PubMed

    Richard, Jean-Christophe M; Maggiore, Salvatore Maurizio; Mancebo, Jordi; Lemaire, François; Jonson, Bjorn; Brochard, Laurent

    2006-10-01

    Supine position may contribute to the loss of aerated lung volume in patients with acute respiratory distress syndrome (ARDS). We hypothesized that verticalization increases lung volume and improves gas exchange by reducing the pressure surrounding lung bases. Prospective observational physiological study in a medical ICU. In 16 patients with ARDS we measured arterial blood gases, pressure-volume curves of the respiratory system recorded from positive-end expiratory pressure (PEEP), and changes in lung volume in supine and vertical positions (trunk elevated at 45 degrees and legs down at 45 degrees ). Vertical positioning increased PaO(2) significantly from 94+/-33 to 142+/-49 mmHg, with an increase higher than 40% in 11 responders. The volume at 20 cmH(2)O measured on the PV curve from PEEP increased using the vertical position only in responders (233+/-146 vs. -8+/-9 1ml in nonresponders); this change was correlated to oxygenation change (rho=0.55). End-expiratory lung volume variation from supine to vertical and 1 h later back to supine, measured in 12 patients showed a significant increase during the 1-h upright period in responders (n=7) but not in nonresponders (n=5; 215+/-220 vs. 10+/-22 ml), suggesting a time-dependent recruitment. Vertical positioning is a simple technique that may improve oxygenation and lung recruitment in ARDS patients.

  8. Comparison between conventional and protective one-lung ventilation for ventilator-assisted thoracic surgery.

    PubMed

    Ahn, H J; Kim, J A; Yang, M; Shim, W S; Park, K J; Lee, J J

    2012-09-01

    Recent papers suggest protective ventilation (PV) as a primary ventilation strategy during one-lung ventilation (OLV) to reduce postoperative pulmonary morbidity. However, data regarding the advantage of the PV strategy in patients with normal preoperative pulmonary function are inconsistent, especially in the case of minimally invasive thoracic surgery. Therefore we compared conventional OLV (VT 10 ml/kg, FiO2 1.0, zero PEEP) to protective OLV (VT 6 ml/kg, FiO2 0.5, PEEP 5 cmH2O) in patients with normal preoperative pulmonary function tests undergoing video-assisted thoracic surgery. Oxygenation, respiratory mechanics, plasma interleukin-6 and malondialdehyde levels were measured at baseline, 15 and 60 minutes after OLV and 15 minutes after restoration of two-lung ventilation. PaO2 and PaO2/FiO2 were higher in conventional OLV than in protective OLV (P<0.001). Interleukin-6 and malondialdehyde increased over time in both groups (P<0.05); however, the magnitudes of increase were not different between the groups. Postoperatively there were no differences in the number of patients with PaO2/FiO2<300 mmHg or abnormalities on chest radiography. Protective ventilation did not provide advantages over conventional ventilation for video-assisted thoracic surgery in this group of patients with normal lung function.

  9. Functional flexibility in wild bonobo vocal behaviour

    PubMed Central

    Archbold, Jahmaira; Zuberbühler, Klaus

    2015-01-01

    A shared principle in the evolution of language and the development of speech is the emergence of functional flexibility, the capacity of vocal signals to express a range of emotional states independently of context and biological function. Functional flexibility has recently been demonstrated in the vocalisations of pre-linguistic human infants, which has been contrasted to the functionally fixed vocal behaviour of non-human primates. Here, we revisited the presumed chasm in functional flexibility between human and non-human primate vocal behaviour, with a study on our closest living primate relatives, the bonobo (Pan paniscus). We found that wild bonobos use a specific call type (the “peep”) across a range of contexts that cover the full valence range (positive-neutral-negative) in much of their daily activities, including feeding, travel, rest, aggression, alarm, nesting and grooming. Peeps were produced in functionally flexible ways in some contexts, but not others. Crucially, calls did not vary acoustically between neutral and positive contexts, suggesting that recipients take pragmatic information into account to make inferences about call meaning. In comparison, peeps during negative contexts were acoustically distinct. Our data suggest that the capacity for functional flexibility has evolutionary roots that predate the evolution of human speech. We interpret this evidence as an example of an evolutionary early transition away from fixed vocal signalling towards functional flexibility. PMID:26290789

  10. Personalizing mechanical ventilation for acute respiratory distress syndrome.

    PubMed

    Berngard, S Clark; Beitler, Jeremy R; Malhotra, Atul

    2016-03-01

    Lung-protective ventilation with low tidal volumes remains the cornerstone for treating patient with acute respiratory distress syndrome (ARDS). Personalizing such an approach to each patient's unique physiology may improve outcomes further. Many factors should be considered when mechanically ventilating a critically ill patient with ARDS. Estimations of transpulmonary pressures as well as individual's hemodynamics and respiratory mechanics should influence PEEP decisions as well as response to therapy (recruitability). This summary will emphasize the potential role of personalized therapy in mechanical ventilation.

  11. Negative pressure pulmonary oedema: a rare case report of two brothers.

    PubMed

    Jaafarpour, Molouk; Khajavikhan, Javaher; Khani, Ali

    2013-10-01

    Negative Pressure Pulmonary O/Edema (NPPE) is potentially life-threatening and it is a general anaesthesia side effect. We are mentioning a rare case report of two brothers who were referred to our hospital for elective surgeries (varicocele and septoplasty) in a 3 years period. Both of them were athletes and their coagulation factors were disturbed after surgeries. Pulmonary oedema was healed after treating it by reintubation, mechanical ventilation by Positive End-Expiratory Pressure (PEEP), diuretics, morphine, Fresh Frozen Plasma (FFP) and liquid bounding.

  12. Negative Pressure Pulmonary Oedema: A Rare Case Report of Two Brothers

    PubMed Central

    Jaafarpour, Molouk; Khajavikhan, Javaher; Khani, Ali

    2013-01-01

    Negative Pressure Pulmonary O/Edema (NPPE) is potentially life-threatening and it is a general anaesthesia side effect. We are mentioning a rare case report of two brothers who were referred to our hospital for elective surgeries (varicocele and septoplasty) in a 3 years period. Both of them were athletes and their coagulation factors were disturbed after surgeries. Pulmonary oedema was healed after treating it by reintubation, mechanical ventilation by Positive End-Expiratory Pressure (PEEP), diuretics, morphine, Fresh Frozen Plasma (FFP) and liquid bounding. PMID:24298513

  13. The Effect of Airway Pressure Release Ventilation on Pulmonary Catheter Readings: Specifically Pulmonary Capillary Wedge Pressure in a Swine Model

    DTIC Science & Technology

    2011-01-01

    pressure (PEEP) of 5 cm H2O was initiated. Ventilator mode was changed to APRV with incremental elevations of CPAP -high from 10 to 35 cm H2O. After a...Results. Increasing CPAP caused increased PCWP and LAPmeasurements above their baseline values. Mean PCWP and LAP were linearly related (LAP = 0.66...PCWP + 4.5 cmH2O, R2 = 0.674, and P < .001) over a wide range of high and low CPAP values during APRV. With return to conventional ventilation, PCWP

  14. Development and Evaluation of New Products for the Far-Forward Care of Combat Casualties with Acute Lung Injury

    DTIC Science & Technology

    2006-02-01

    pulmonary artery wedge pressure (PAWP) were determined at each time point. Electrocardiogram (ECG), pulse oximetry ( SpO2 ) (Datex Ohmeda True Tech Plus...cm H2O positive end expiratory pressure (PEEP) and a goal for oxygenation of at least 90% by arterial 8 blood hemoglobin O2 saturation ( SpO2 and...or SaO2). The fraction of inspired O2 concentration was 21% and was adjusted as necessary to maintain SpO2 ≥ 90% and partial pressure of O2 in

  15. Lung Recruitment Maneuvers for Adult Patients with Acute Respiratory Distress Syndrome. A Systematic Review and Meta-Analysis.

    PubMed

    Goligher, Ewan C; Hodgson, Carol L; Adhikari, Neill K J; Meade, Maureen O; Wunsch, Hannah; Uleryk, Elizabeth; Gajic, Ognjen; Amato, Marcelo P B; Ferguson, Niall D; Rubenfeld, Gordon D; Fan, Eddy

    2017-10-01

    In patients with acute respiratory distress syndrome (ARDS), lung recruitment maneuvers (LRMs) may prevent ventilator-induced lung injury and improve survival. To summarize the current evidence in support of the use of LRMs in adult patients with ARDS and to inform the recently published American Thoracic Society/European Society of Intensive Care Medicine/Society of Critical Care Medicine clinical practice guideline on mechanical ventilation in ARDS. We conducted a systematic review and meta-analysis of randomized trials comparing mechanical ventilation strategies with and without LRMs. Eligible trials were identified from among previously published systematic reviews and an updated literature search. Data on 28-day mortality, oxygenation, adverse events, and use of rescue therapy were collected, and results were pooled using random effects models weighted by inverse variance. Strength of evidence was assessed using the Grading of Recommendations Assessment, Development, and Evaluation methodology. We screened 430 citations and previous systematic reviews and found six trials eligible for inclusion (n = 1,423 patients in total). The type of LRM varied widely between trials, and five of the trials involved a cointervention with a higher positive end-expiratory pressure (PEEP) ventilation strategy. Risk of bias was deemed high in one trial. In the primary analysis, the only trial without a cointervention showed that LRMs were associated with reduced mortality (one trial; risk ratio [RR], 0.62; 95% confidence interval [CI], 0.39-0.98; evidence grade = low). Meta-analysis of all six trials also suggested a significant mortality reduction (six trials; RR, 0.81; 95% CI, 0.69-0.95; evidence grade = moderate), and the use of a higher PEEP cointervention did not significantly modify the mortality effect (P = 0.27 for heterogeneity). LRMs were also associated with improved oxygenation after 24 hours (six trials; mean increase, 52 mm Hg; 95% CI, 23-81 mm Hg

  16. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study

    PubMed Central

    Richard, JC; Pouzot, C; Gros, A; Tourevieille, C; Lebars, D; Lavenne, F; Frerichs, I; Guérin, C

    2009-01-01

    Introduction Electrical impedance tomography (EIT), which can assess regional lung ventilation at the bedside, has never been compared with positron-emission tomography (PET), a gold-standard to quantify regional ventilation. This experiment systematically compared both techniques in injured and non-injured lungs. Methods The study was performed in six mechanically ventilated female piglets. In normal lungs, tidal volume (VT) was randomly changed to 6, 8, 10 and 15 ml/kg on zero end-expiratory pressure (ZEEP), then, at VT 10 ml/kg, positive end-expiratory pressure (PEEP) was randomly changed to 5, 10 and 15 cmH2O. Afterwards, acute lung injury (ALI) was subsequently created in three animals by injecting 3 ml/kg hydrochloric acid into the trachea. Then at PEEP 5 cmH2O, VT was randomly changed to 8 and 12 ml/kg and PEEP of 10 and 15 cmH2O applied at VT 10 ml/kg. EIT and PET examinations were performed simultaneously. EIT ventilation (VTEIT) and lung volume (VL) were measured in the anterior and posterior area of each lung. On the same regions of interest, ventilation (VPET) and aerated lung volume (VAatten) were determined with PET. Results On ZEEP, VTEIT and VPET significantly correlated for global (VTEIT = VPET - 2E-13, R2 = 0.95, P < 0.001) and regional (VTEIT = 0.81VPET+7.65, R2 = 0.63, P < 0.001) ventilation over both conditions. For ALI condition, corresponding R2 were 0.91 and 0.73 (P < 0.01). Bias was = 0 and limits of agreement were -37.42 and +37.42 ml/min for global ventilation over both conditions. These values were 0.04 and -29.01 and +29.08 ml/min, respectively, for regional ventilation. Significant correlations were also found between VL and VAatten for global (VL = VAatten+1E-12, R2 = 0.93, P < 0.0001) and regional (VL = 0.99VAatten+0.92, R2 = 0.65, P < 0.001) volume. For ALI condition, corresponding R2 were 0.94 (P < 0.001) and 0.54 (P < 0.05). Bias was = 0 and limits of agreement ranged -38.16 and +38.16 ml for global ventilation over both

  17. Final postflight hardware evaluation report RSRM-28 (STS-53)

    NASA Technical Reports Server (NTRS)

    Starrett, William David, Jr.

    1993-01-01

    The final report for the Clearfield disassembly evaluation and a continuation of the KSC postflight assessment for the RSRM-28 (STS-53) RSRM flight set is presented. All observed hardware conditions were documented on PFOR's and are included in Appendices A through C. Appendices D and E contain the measurements and safety factor data for the nozzle and insulation components. This report, along with the KSC Ten-Day Postflight Hardware Evaluation Report (TWR-64215), represents a summary of the RSRM-28 hardware evaluation. The as-flown hardware configuration is documented in TWR-63638. Disassembly evaluation photograph numbers are logged in TWA-1989. The RSRM-28 flight set disassembly evaluations described were performed at the RSRM Refurbishment Facility in Clearfield, Utah. The final factory joint demate occurred on July 15, 1993. Additional time was required to perform the evaluation of the stiffener rings per special issue 4.1.5.2 because of the washout schedule. The release of this report was after completion of all special issues per program management direction. Detailed evaluations were performed in accordance with the Clearfield PEEP, TWR-50051, Revision A. All observations were compared against limits that are also defined in the PEEP. These limits outline the criteria for categorizing the observations as acceptable, reportable, or critical. Hardware conditions that were unexpected and/or determined to be reportable or critical were evaluated by the applicable team and tracked through the PFAR system.

  18. Lung imaging in rodents using dual energy micro-CT

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Guo, X.; Clark, D.; Johnston, S. M.; Marshall, C.; Piantadosi, C.

    2012-03-01

    Dual energy CT imaging is expected to play a major role in the diagnostic arena as it provides material decomposition on an elemental basis. The purpose of this work is to investigate the use of dual energy micro-CT for the estimation of vascular, tissue, and air fractions in rodent lungs using a post-reconstruction three-material decomposition method. We have tested our method using both simulations and experimental work. Using simulations, we have estimated the accuracy limits of the decomposition for realistic micro-CT noise levels. Next, we performed experiments involving ex vivo lung imaging in which intact lungs were carefully removed from the thorax, were injected with an iodine-based contrast agent and inflated with air at different volume levels. Finally, we performed in vivo imaging studies in (n=5) C57BL/6 mice using fast prospective respiratory gating in endinspiration and end-expiration for three different levels of positive end-expiratory pressure (PEEP). Prior to imaging, mice were injected with a liposomal blood pool contrast agent. The mean accuracy values were for Air (95.5%), Blood (96%), and Tissue (92.4%). The absolute accuracy in determining all fraction materials was 94.6%. The minimum difference that we could detect in material fractions was 15%. As expected, an increase in PEEP levels for the living mouse resulted in statistically significant increases in air fractions at end-expiration, but no significant changes in end-inspiration. Our method has applicability in preclinical pulmonary studies where various physiological changes can occur as a result of genetic changes, lung disease, or drug effects.

  19. Effect of prone positioning on cannula function and impaired oxygenation during extracorporeal circulation.

    PubMed

    Masuda, Yoshiki; Tatsumi, Hiroomi; Imaizumi, Hitoshi; Gotoh, Kyoko; Yoshida, Shinichiro; Chihara, Shinya; Takahashi, Kanako; Yamakage, Michiaki

    2014-03-01

    Prone ventilation is an effective method for improving oxygenation in patients with acute respiratory failure. However, in extracorporeal circulation, there is a risk of cannula-related complications when changing the position. In this study, we investigated cannula-related complications when changing position for prone ventilation and the effect of prone ventilation on impaired oxygenation in patients who underwent extracorporeal membrane oxygenation (ECMO). The study subjects were patients who underwent prone ventilation during ECMO in the period from 2004 to 2011. Indication for prone ventilation was the presence of dorsal infiltration shown by lung computed tomography. Factors investigated were cannula insertion site, dislodgement or obstruction of the cannula, malfunction of vascular access and unplanned dislodgement of the catheters when changing position. Mean arterial pressure, PaO2/FiO2, PEEP level, blood flow and rotation speed of the pump were also determined before and after position change. Five patients were selected as study subjects. The mean duration of prone positioning was 15.3 ± 0.5 h. Strict management during position changes prevented cannula-related complications in the patients who underwent extracorporeal circulation. There were no significant changes in mean arterial pressure, PEEP level, blood flow and rotation speed of the pump when changing position. Low PaO2/FiO2 prior to prone ventilation was significantly increased after supine to prone and then prone to supine position. Prone positioning to improve impaired oxygenation is a safe procedure and not a contraindication in patients receiving extracorporeal circulation.

  20. Positive-pressure ventilation during transport: a randomized crossover study of self-inflating and flow-inflating resuscitators in a simulation model.

    PubMed

    Lucy, Malcolm J; Gamble, Jonathan J; Daku, Brian L; Bryce, Rhonda D; Rana, Masud

    2014-12-01

    Positive-pressure ventilation during transport of intubated patients is generally delivered via a hand-pressurized device. Of these devices, self-inflating resuscitators (SIR) and flow-inflating resuscitators (FIR) constitute the two major types used. Selection of a particular device for transport, however, remains largely an institutional practice. To evaluate the hypothesis that transport ventilation goals of intubated pediatric patients are better achieved using an FIR compared to an SIR. This randomized crossover simulation study compared the performance of SIR and FIR among anesthesia providers in a pediatric transport scenario. Subjects hand-ventilated a test lung while simultaneously maneuvering a stretcher bed to simulate patient transport. Hand ventilation was carried out using a Jackson-Rees circuit (FIR) and a Laerdal pediatric silicone resuscitator (SIR). The primary outcome was the proportion of total breaths delivered within the predefined target PIP/PEEP range (30+/- 3, 10+/- 3 cm H2O). Secondary outcomes included proportion of total breaths delivered with operationally defined unacceptable breath variables (PIP > 35 cm H2O or PEEP < 5 cm H2O). Overall, participants were four times more likely to deliver target breaths and one-third less likely to deliver unacceptable breaths using the FIR compared to the SIR. When comparing device performance, a 44% increase in the proportions of target breaths and a 40.4% decrease in unacceptable breaths using the FIR were observed (P < 0.0001 for both). Hand ventilation during patient transport is superior using the FIR compared to the SIR to achieve target ventilatory goals and avoid unacceptable ventilatory cycles. © 2014 John Wiley & Sons Ltd.

  1. Intraoperative mechanical ventilation: state of the art.

    PubMed

    Ball, Lorenzo; Costantino, Federico; Orefice, Giulia; Chandrapatham, Karthikka; Pelosi, Paolo

    2017-10-01

    Mechanical ventilation is a cornerstone of the intraoperative management of the surgical patient and is still mandatory in several surgical procedures. In the last decades, research focused on preventing postoperative pulmonary complications (PPCs), both improving risk stratification through the use of predictive scores and protecting the lung adopting so-called protective ventilation strategies. The aim of this review was to give an up-to-date overview of the currently suggested intraoperative ventilation strategies, along with their pathophysiologic rationale, with a focus on challenging conditions, such as obesity, one-lung ventilation and cardiopulmonary bypass. While anesthesia and mechanical ventilation are becoming increasingly safe practices, the contribution to surgical mortality attributable to postoperative lung injury is not negligible: for these reasons, the prevention of PPCs, including the use of protective mechanical ventilation is mandatory. Mechanical ventilation should be optimized providing an adequate respiratory support while minimizing unwanted negative effects. Due to the high number of surgical procedures performed daily, the impact on patients' health and healthcare costs can be relevant, even when new strategies result in an apparently small improvement of outcome. A protective intraoperative ventilation should include a low tidal volume of 6-8 mL/kg of predicted body weight, plateau pressures ideally below 16 cmH2O, the lowest possible driving pressure, moderate-low PEEP levels except in obese patients, laparoscopy and long surgical procedures that might benefit of a slightly higher PEEP. The work of the anesthesiologist should start with a careful preoperative visit to assess the risk, and a close postoperative monitoring.

  2. The effect of low level laser therapy on ventilator-induced lung injury in mice (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Szabari, Margit V.; Miller, Alyssa J.; Hariri, Lida P.; Hamblin, Michael R.; Musch, Guido; Stroh, Helene; Suter, Melissa J.

    2016-03-01

    Although mechanical ventilation (MV) is necessary to support gas exchange in critically ill patients, it can contribute to the development of lung injury and multiple organ dysfunction. It is known that high tidal volume (Vt) MV can cause ventilator-induced lung injury (VILI) in healthy lungs and increase the mortality of patients with Acute Respiratory Distress Syndrome. Low level laser therapy (LLLT) has demonstrated to have anti-inflammatory effects. We investigated whether LLLT could alleviate inflammation from injurious MV in mice. Adult mice were assigned to 2 groups: VILI+LLLT group (3 h of injurious MV: Vt=25-30 ml/kg, respiratory rate (RR)=50/min, positive end-expiratory pressure (PEEP)=0 cmH20, followed by 3 h of protective MV: Vt=9 ml/kg, RR=140/min, PEEP=2 cmH20) and VILI+no LLLT group. LLLT was applied during the first 30 min of the MV (810 nm LED system, 5 J/cm2, 1 cm above the chest). Respiratory impedance was measured in vivo with forced oscillation technique and lung mechanics were calculated by fitting the constant phase model. At the end of the MV, bronchoalveolar lavage (BAL) was performed and inflammatory cells counted. Lungs were removed en-bloc and fixed for histological evaluation. We hypothesize that LLLT can reduce lung injury and inflammation from VILI. This therapy could be translated into clinical practice, where it can potentially improve outcomes in patients requiring mechanical ventilation in the operating room or in the intensive care units.

  3. Alveolar derecruitment and collapse induration as crucial mechanisms in lung injury and fibrosis.

    PubMed

    Lutz, Dennis; Gazdhar, Amiq; Lopez-Rodriguez, Elena; Ruppert, Clemens; Mahavadi, Poornima; Günther, Andreas; Klepetko, Walter; Bates, Jason H; Smith, Bradford; Geiser, Thomas; Ochs, Matthias; Knudsen, Lars

    2015-02-01

    Idiopathic pulmonary fibrosis (IPF) and bleomycin-induced pulmonary fibrosis are associated with surfactant system dysfunction, alveolar collapse (derecruitment), and collapse induration (irreversible collapse). These events play undefined roles in the loss of lung function. The purpose of this study was to quantify how surfactant inactivation, alveolar collapse, and collapse induration lead to degradation of lung function. Design-based stereology and invasive pulmonary function tests were performed 1, 3, 7, and 14 days after intratracheal bleomycin-instillation in rats. The number and size of open alveoli was correlated to mechanical properties. Active surfactant subtypes declined by Day 1, associated with a progressive alveolar derecruitment and a decrease in compliance. Alveolar epithelial damage was more pronounced in closed alveoli compared with ventilated alveoli. Collapse induration occurred on Day 7 and Day 14 as indicated by collapsed alveoli overgrown by a hyperplastic alveolar epithelium. This pathophysiology was also observed for the first time in human IPF lung explants. Before the onset of collapse induration, distal airspaces were easily recruited, and lung elastance could be kept low after recruitment by positive end-expiratory pressure (PEEP). At later time points, the recruitable fraction of the lung was reduced by collapse induration, causing elastance to be elevated at high levels of PEEP. Surfactant inactivation leading to alveolar collapse and subsequent collapse induration might be the primary pathway for the loss of alveoli in this animal model. Loss of alveoli is highly correlated with the degradation of lung function. Our ultrastructural observations suggest that collapse induration is important in human IPF.

  4. [Effect of transpulmonary pressure-directed mechanical ventilation on respiration in severe acute pancreatitis patient with intraabdominal hypertension].

    PubMed

    Wu, Xiaoyan; Zheng, Ruiqiang; Lin, Hua; Zhuang, Zhiqing; Zhang, Min; Yan, Peixia

    2015-10-20

    To assess the effect of mehanical ventilation (MV) guided by transpulmonary pressure (Ptp) on respiratory mechanics and gas exchange in severe acute pancreatitis patient with intraabdominal hypertension. Twelve severe acute pancreatitis patient with intraabdominal hypertension and acute respiratory distress syndrome(ARDS) underwent mechanical ventilation were involved from Jan to Dec 2013. PEEP levels were set to achieve a Ptp of 0 to 10 cm of water at end expiration. We also limited tidal volume to keep Ptp at less than 25 cm of water at end inspiration. Respiratory mechanics and gas-exchange were measured. Plat pressure (Pplat) increased and the compliance of chest wall (Ccw) decreased when intraabdominal pressure (IAP) increased. Pplat correlated with IAP positively (r2=0.741 9, P<0.05) and Ccw correlated with IAP negtively (r2=0.722 2, P<0.05), respectively.There were not corrletions between IAP and end-expiratory Ptp (Ptp-e) and end-inspiratory Ptp (Ptp-i) (P>0.05). Compared with baseline, after guiding MV with Ptp, the Level of PEEP (14.6±4.2) cmH2O vs (8.3±2.0) cmH2O, and Ptp-e (1.5±0.5) cmH2O vs (-2.3±1.4) cmH2O increased (P<0.05) and Ptp-i did not increase significantly (P>0.05). Ptp-e correlated with PEEP (r2=0.549, P<0.05) and end-expiratory esophageal pressure (Pes-e) (r2=0.260, P<0.05). Ptp-i correlated with Pplat (r2=0.523, P<0.05) and end-inspiratory esophageal pressure (Pes-i) (r2=0.231, P<0.05), but did not correlate with Tidal volume(VT) (r2=0.052 4, P>0.05). Compared with baseline, lung compliance (CL) (48.1±10.3) cmH2O vs (25.7±6.4) cmH2O and oxygenation index (PaO2/FiO2) (235±48) mmHg vs (160±35) mmHg improved obviously (P<0.05), dead space fraction (VD/VT) (0.48±0.07) vs (0.59±0.06) decreased (P<0.05), but Ccw and respiratory compliance(Cr) didn't improve (P>0.05). Transpulmonary pressure-directed mechanical ventilation in ARDS secondary to severe acute pancreatitis patient with intraabdominal hypertension could not only recruit

  5. Feasibility and safety of low-flow extracorporeal carbon dioxide removal to facilitate ultra-protective ventilation in patients with moderate acute respiratory distress sindrome.

    PubMed

    Fanelli, Vito; Ranieri, Marco V; Mancebo, Jordi; Moerer, Onnen; Quintel, Michael; Morley, Scott; Moran, Indalecio; Parrilla, Francisco; Costamagna, Andrea; Gaudiosi, Marco; Combes, Alain

    2016-02-10

    Mechanical ventilation with a tidal volume (VT) of 6 mL/kg/predicted body weight (PBW), to maintain plateau pressure (Pplat) lower than 30 cmH2O, does not completely avoid the risk of ventilator induced lung injury (VILI). The aim of this study was to evaluate safety and feasibility of a ventilation strategy consisting of very low VT combined with extracorporeal carbon dioxide removal (ECCO2R). In fifteen patients with moderate ARDS, VT was reduced from baseline to 4 mL/kg PBW while PEEP was increased to target a plateau pressure--(Pplat) between 23 and 25 cmH2O. Low-flow ECCO2R was initiated when respiratory acidosis developed (pH < 7.25, PaCO2 > 60 mmHg). Ventilation parameters (VT, respiratory rate, PEEP), respiratory compliance (CRS), driving pressure (DeltaP = VT/CRS), arterial blood gases, and ECCO2R system operational characteristics were collected during the period of ultra-protective ventilation. Patients were weaned from ECCO2R when PaO2/FiO2 was higher than 200 and could tolerate conventional ventilation settings. Complications, mortality at day 28, need for prone positioning and extracorporeal membrane oxygenation, and data on weaning from both MV and ECCO2R were also collected. During the 2 h run in phase, VT reduction from baseline (6.2 mL/kg PBW) to approximately 4 mL/kg PBW caused respiratory acidosis (pH < 7.25) in all fifteen patients. At steady state, ECCO2R with an average blood flow of 435 mL/min and sweep gas flow of 10 L/min was effective at correcting pH and PaCO2 to within 10 % of baseline values. PEEP values tended to increase at VT of 4 mL/kg from 12.2 to 14.5 cmH2O, but this change was not statistically significant. Driving pressure was significantly reduced during the first two days compared to baseline (from 13.9 to 11.6 cmH2O; p < 0.05) and there were no significant differences in the values of respiratory system compliance. Rescue therapies for life threatening hypoxemia such as prone position and ECMO were necessary in four and two

  6. [Asymmetric negative pressure pulmonary edema after acute upper airway obstruction: case report].

    PubMed

    Peixoto, Aldo José

    2002-06-01

    Negative pressure pulmonary edema after acute upper airway obstruction is a well-described event, though infrequently diagnosed and reported. This report aimed at presenting a case of upper airway obstruction negative pressure pulmonary edema following acute upper airway obstruction characterized by pulmonary edema asymmetry, being more prominent in the right lung. A 4-year-old boy, 17 kg, phisical status ASA I submitted to combined tonsillectomy, adenoidectomy and turbinate cauterization under general anesthesia with sevoflurane/nitrous oxide/O2. Surgery duration was 90 minutes without complications. During anesthetic recovery and spontaneously breathing, patient reacted to tracheal tube, which was removed. Following, ventilatory efforts resulted in chest wall retraction without apparent air movement, being impossible to ventilate him with facial mask. Symptoms evolved to severe hypoxemia (50% SpO2) requiring reintubation. At this point, it was observed that the lung was stiffer and there were bilateral rales characterizing pulmonary edema. A chest X-ray showed diffuse bilateral infiltrates, right upper lobe atelectasis and marked pulmonary edema asymmetry (right greater than left). Patient was mechanically ventilated with PEEP for 20 hours when he was extubated. There was a progressive pulmonary edema improvement and patient was discharged 48 hours later. Negative pressure pulmonary edema (NPPE) is a rare event with high morbidity risk. It is often not diagnosed and requires from the anesthesiologist an updated knowledge and adequate management. It is usually bilateral, rarely unilateral, and exceptionally asymmetric as in this case. Most cases are treated by mechanical ventilation with PEEP or CPAP without any other therapy. The prognosis is favorable, with most cases recovering within the first 24 hours.

  7. The Evaluation of a Pulmonary Display to Detect Adverse Respiratory Events Using High Resolution Human Simulator

    PubMed Central

    Wachter, S. Blake; Johnson, Ken; Albert, Robert; Syroid, Noah; Drews, Frank; Westenskow, Dwayne

    2006-01-01

    Objective Authors developed a picture-graphics display for pulmonary function to present typical respiratory data used in perioperative and intensive care environments. The display utilizes color, shape and emergent alerting to highlight abnormal pulmonary physiology. The display serves as an adjunct to traditional operating room displays and monitors. Design To evaluate the prototype, nineteen clinician volunteers each managed four adverse respiratory events and one normal event using a high-resolution patient simulator which included the new displays (intervention subjects) and traditional displays (control subjects). Between-group comparisons included (i) time to diagnosis and treatment for each adverse respiratory event; (ii) the number of unnecessary treatments during the normal scenario; and (iii) self-reported workload estimates while managing study events. Measurements Two expert anesthesiologists reviewed video-taped transcriptions of the volunteers to determine time to treat and time to diagnosis. Time values were then compared between groups using a Mann-Whitney-U Test. Estimated workload for both groups was assessed using the NASA-TLX and compared between groups using an ANOVA. P-values < 0.05 were considered significant. Results Clinician volunteers detected and treated obstructed endotracheal tubes and intrinsic PEEP problems faster with graphical rather than conventional displays (p < 0.05). During the normal scenario simulation, 3 clinicians using the graphical display, and 5 clinicians using the conventional display gave unnecessary treatments. Clinician-volunteers reported significantly lower subjective workloads using the graphical display for the obstructed endotracheal tube scenario (p < 0.001) and the intrinsic PEEP scenario (p < 0.03). Conclusion Authors conclude that the graphical pulmonary display may serve as a useful adjunct to traditional displays in identifying adverse respiratory events. PMID:16929038

  8. A quasi-experimental, before-after trial examining the impact of an emergency department mechanical ventilator protocol on clinical outcomes and lung-protective ventilation in acute respiratory distress syndrome

    PubMed Central

    Fuller, Brian M.; Ferguson, Ian T.; Mohr, Nicholas M.; Drewry, Anne M.; Palmer, Christopher; Wessman, Brian T.; Ablordeppey, Enyo; Keeperman, Jacob; Stephens, Robert J.; Briscoe, Cristopher C.; Kolomiets, Angelina A.; Hotchkiss, Richard S.; Kollef, Marin H.

    2017-01-01

    Objective To evaluate the impact of an emergency department (ED) mechanical ventilation protocol on clinical outcomes and adherence to lung-protective ventilation in patients with acute respiratory distress syndrome (ARDS). Design Quasi-experimental, before-after trial. Setting ED and intensive care units (ICU) of an academic center. Patients Mechanically ventilated ED patients experiencing ARDS while in the ED or after admission to the ICU. Interventions An ED ventilator protocol which targeted parameters in need of quality improvement, as identified by prior work: 1) lung-protective tidal volume; 2) appropriate setting of positive end-expiratory pressure (PEEP); 3) oxygen weaning; and 4) head-of-bed elevation. Measurements and Main Results A total of 229 patients (186 pre-intervention group, 43 intervention group) were studied. In the ED, the intervention was associated with significant changes (P < 0.01 for all) in tidal volume, PEEP, respiratory rate, oxygen administration, and head-of-bed elevation. There was a reduction in ED tidal volume from 8.1 mL/kg PBW (7.0 – 9.1) to 6.4 mL/kg PBW (6.1 – 6.7), and an increase in lung-protective ventilation from 11.1% to 61.5%, P < 0.01. The intervention was associated with a reduction in mortality from 54.8% to 39.5% (OR 0.38, 95% CI 0.17 – 0.83, P = 0.02), and a 3.9 day increase in ventilator-free days, P = 0.01. Conclusions This before-after study of mechanically ventilated patients with ARDS demonstrates that implementing a mechanical ventilator protocol in the ED is feasible, and associated with improved clinical outcomes. PMID:28157140

  9. Transdermal granisetron for the prevention of nausea and vomiting following moderately or highly emetogenic chemotherapy in Chinese patients: a randomized, double-blind, phase III study.

    PubMed

    Yang, Liu-Qing; Sun, Xin-Chen; Qin, Shu-Kui; Chen, Ying-Xia; Zhang, He-Long; Cheng, Ying; Chen, Zhen-Dong; Shi, Jian-Hua; Wu, Qiong; Bai, Yu-Xian; Han, Bao-Hui; Liu, Wei; Ouyang, Xue-Nong; Liu, Ji-Wei; Zhang, Zhi-Hui; Li, Yong-Qiang; Xu, Jian-Ming; Yu, Shi-Ying

    2016-12-01

    The granisetron transdermal delivery system (GTDS) has been demonstrated effectiveness in the control of chemotherapy-induced nausea and vomiting (CINV) in previous studies. This is the first phase III study to evaluate the efficacy and tolerability of GTDS in patients receiving moderately emetogenic chemotherapy (MEC) or highly emetogenic chemotherapy (HEC) in China. A total of 313 patients were randomized into the GTDS group (one transdermal granisetron patch, 7 days) or the oral granisetron group (granisetron oral 2 mg/day, ≥2 days). The primary endpoint was the percentage of patients achieving complete control (CC) from chemotherapy initiation until 24 h after final administration (PEEP). Chi-square test and Fisher's exact test were used for statistical analysis. Two hundred eighty-one patients were included in the per protocol analysis. During PEEP, CC was achieved by 67 (47.52%) patients in the GTDS group and 83 (59.29%) patients in the oral granisetron group. There was no statistical significance between the groups (P=0.0559). However, the difference of the CC percentage mainly occurred on the first day of chemotherapy between the groups. The CC was 70.13% on day 1 in the GTDS group, which was significantly lower than that of 91.03% in the oral granisetron group in the full analysis set. In the following days of chemotherapy, the CC was similar between the groups. In terms of cisplatin-contained regimen and female, there was statistical significance between the groups. Both treatments were well tolerated and safe. The most common adverse event was constipation. GTDS provided effective and well-tolerated control of CINV in Chinese patients, especially to non-cisplatin-contained regimen.

  10. Ventilatory strategies and supportive care in acute respiratory distress syndrome.

    PubMed

    Luks, Andrew M

    2013-11-01

    While antiviral therapy is an important component of care in patients with the acute respiratory distress syndrome (ARDS) following influenza infection, it is not sufficient to ensure good outcomes, and additional measures are usually necessary. Patients usually receive high levels of supplemental oxygen to counteract the hypoxemia resulting from severe gas exchange abnormalities. Many patients also receive invasive mechanical ventilation for support for oxygenation, while in resource-poor settings, supplemental oxygen via face mask may be the only available intervention. Patients with ARDS receiving mechanical ventilation should receive lung-protective ventilation, whereby tidal volume is decreased to 6 ml/kg of their predicted weight and distending pressures are maintained ≤ 30 cm H2 O, as well as increased inspired oxygen concentrations and positive end-expiratory pressure (PEEP) to prevent atelectasis and support oxygenation. While these measures are sufficient in most patients, a minority develop refractory hypoxemia and may receive additional therapies, including prone positioning, inhaled vasodilators, extracorporeal membrane oxygenation, recruitment maneuvers followed by high PEEP, and neuromuscular blockade, although recent data suggest that this last option may be warranted earlier in the clinical course before development of refractory hypoxemia. Application of these "rescue strategies" is complicated by the lack of guidance in the literature regarding implementation. While much attention is devoted to these strategies, clinicians must not lose sight of simple interventions that affect patient outcomes including head of bed elevation, prophylaxis against venous thromboembolism and gastrointestinal bleeding, judicious use of fluids in the post-resuscitative phase, and a protocol-based approach to sedation and spontaneous breathing trials. © 2013 Blackwell Publishing Ltd.

  11. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    PubMed

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  12. Genesis of the characteristic pulmonary venous pressure waveform as described by the reservoir-wave model

    PubMed Central

    Bouwmeester, J Christopher; Belenkie, Israel; Shrive, Nigel G; Tyberg, John V

    2014-01-01

    Conventional haemodynamic analysis of pulmonary venous and left atrial (LA) pressure waveforms yields substantial forward and backward waves throughout the cardiac cycle; the reservoir wave model provides an alternative analysis with minimal waves during diastole. Pressure and flow in a single pulmonary vein (PV) and the main pulmonary artery (PA) were measured in anaesthetized dogs and the effects of hypoxia and nitric oxide, volume loading, and positive-end expiratory pressure (PEEP) were observed. The reservoir wave model was used to determine the reservoir contribution to PV pressure and flow. Subtracting reservoir pressure and flow resulted in ‘excess’ quantities which were treated as wave-related. Wave intensity analysis of excess pressure and flow quantified the contributions of waves originating upstream (from the PA) and downstream (from the LA and/or left ventricle (LV)). Major features of the characteristic PV waveform are caused by sequential LA and LV contraction and relaxation creating backward compression (i.e. pressure-increasing) waves followed by decompression (i.e. pressure-decreasing) waves. Mitral valve opening is linked to a backwards decompression wave (i.e. diastolic suction). During late systole and early diastole, forward waves originating in the PA are significant. These waves were attenuated less with volume loading and delayed with PEEP. The reservoir wave model shows that the forward and backward waves are negligible during LV diastasis and that the changes in pressure and flow can be accounted for by the discharge of upstream reservoirs. In sharp contrast, conventional analysis posits forward and backward waves such that much of the energy of the forward wave is opposed by the backward wave. PMID:25015922

  13. Development of three methods for extracting respiration from the surface ECG: a review.

    PubMed

    Helfenbein, Eric; Firoozabadi, Reza; Chien, Simon; Carlson, Eric; Babaeizadeh, Saeed

    2014-01-01

    comparison of EMGDR breath locations to the reference abdominal belt signal yielded sensitivity/PPV of 94/95%. 4) Another comparison study for breath detection during MRI yielded sensitivity/PPV pairs of EDR: 99/97, RSA: 79/78, and EMGDR: 89/86%. 5) We tested EMGDR performance in the presence of simulated respiratory disease using CPAP to produce PEEP. For 10 patients, no false breath waveforms were generated with mild PEEP, but they appeared in 2 subjects at high PEEP. 6) A patient monitoring study compared RR computation from EDR to impedance-derived RR, and showed that EDR provides a near equivalent RR measurement with reduced hardware circuitry requirements. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Individualised perioperative open-lung approach versus standard protective ventilation in abdominal surgery (iPROVE): a randomised controlled trial.

    PubMed

    Ferrando, Carlos; Soro, Marina; Unzueta, Carmen; Suarez-Sipmann, Fernando; Canet, Jaume; Librero, Julián; Pozo, Natividad; Peiró, Salvador; Llombart, Alicia; León, Irene; India, Inmaculada; Aldecoa, Cesar; Díaz-Cambronero, Oscar; Pestaña, David; Redondo, Francisco J; Garutti, Ignacio; Balust, Jaume; García, Jose I; Ibáñez, Maite; Granell, Manuel; Rodríguez, Aurelio; Gallego, Lucía; de la Matta, Manuel; Gonzalez, Rafael; Brunelli, Andrea; García, Javier; Rovira, Lucas; Barrios, Francisco; Torres, Vicente; Hernández, Samuel; Gracia, Estefanía; Giné, Marta; García, María; García, Nuria; Miguel, Lisset; Sánchez, Sergio; Piñeiro, Patricia; Pujol, Roger; García-Del-Valle, Santiago; Valdivia, José; Hernández, María J; Padrón, Oto; Colás, Ana; Puig, Jaume; Azparren, Gonzalo; Tusman, Gerardo; Villar, Jesús; Belda, Javier

    2018-03-01

    The effects of individualised perioperative lung-protective ventilation (based on the open-lung approach [OLA]) on postoperative complications is unknown. We aimed to investigate the effects of intraoperative and postoperative ventilatory management in patients scheduled for abdominal surgery, compared with standard protective ventilation. We did this prospective, multicentre, randomised controlled trial in 21 teaching hospitals in Spain. We enrolled patients who were aged 18 years or older, were scheduled to have abdominal surgery with an expected time of longer than 2 h, had intermediate-to-high-risk of developing postoperative pulmonary complications, and who had a body-mass index less than 35 kg/m 2 . Patients were randomly assigned (1:1:1:1) online to receive one of four lung-protective ventilation strategies using low tidal volume plus positive end-expiratory pressure (PEEP): open-lung approach (OLA)-iCPAP (individualised intraoperative ventilation [individualised PEEP after a lung recruitment manoeuvre] plus individualised postoperative continuous positive airway pressure [CPAP]), OLA-CPAP (intraoperative individualised ventilation plus postoperative CPAP), STD-CPAP (standard intraoperative ventilation plus postoperative CPAP), or STD-O 2 (standard intraoperative ventilation plus standard postoperative oxygen therapy). Patients were masked to treatment allocation. Investigators were not masked in the operating and postoperative rooms; after 24 h, data were given to a second investigator who was masked to allocations. The primary outcome was a composite of pulmonary and systemic complications during the first 7 postoperative days. We did the primary analysis using the modified intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT02158923. Between Jan 2, 2015, and May 18, 2016, we enrolled 1012 eligible patients. Data were available for 967 patients, whom we included in the final analysis. Risk of pulmonary and systemic

  15. Aging-related changes in respiratory system mechanics and morphometry in mice.

    PubMed

    Elliott, Jonathan E; Mantilla, Carlos B; Pabelick, Christina M; Roden, Anja C; Sieck, Gary C

    2016-07-01

    Previous work investigating respiratory system mechanics in mice has reported an aging-related increase in compliance and mean linear intercept (Lm). However, these changes were assessed using only a young (2-mo-old) and old (20- and 26-mo-old) group yet were interpreted to reflect a linear evolution across the life span. Therefore, to investigate respiratory system mechanics and lung morphometry across a more complete spectrum of ages, we utilized 2 (100% survival, n = 6)-, 6 (100% survival, n = 12)-, 18 (90% survival, n = 12)-, 24 (75% survival, n = 12)-, and 30 (25% survival, n = 12)-mo-old C57BL/6 mice. We found a nonlinear aging-related decrease in respiratory system resistance and increase in dynamic compliance and hysteresis between 2- and 24-mo-old mice. However, in 30-mo-old mice, respiratory system resistance increased, and dynamic compliance and hysteresis decreased relative to 24-mo-old mice. Respiratory system impedance spectra were measured between 1-20.5 Hz at positive end-expiratory pressures (PEEP) of 1, 3, 5, and 7 cmH2O. Respiratory system resistance and reactance at each level of PEEP were increased and decreased, respectively, only in 2-mo-old animals. No differences in the respiratory system impedance spectra were observed in 6-, 18-, 24-, and 30-mo-old mice. Additionally, lungs were fixed following tracheal instillation of 4% paraformaldehyde at 25 cmH2O and processed for Lm and airway collagen deposition. There was an aging-related increase in Lm consistent with emphysematous-like changes and no evidence of increased airway collagen deposition. Accordingly, we demonstrate nonlinear aging-related changes in lung mechanics and morphometry in C57BL/6 mice. Copyright © 2016 the American Physiological Society.

  16. Actual performance of mechanical ventilators in ICU: a multicentric quality control study.

    PubMed

    Govoni, Leonardo; Dellaca', Raffaele L; Peñuelas, Oscar; Bellani, Giacomo; Artigas, Antonio; Ferrer, Miquel; Navajas, Daniel; Pedotti, Antonio; Farré, Ramon

    2012-01-01

    Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH(2)O/L/s) - elastance (100 mL/cmH(2)O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH(2)O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min-max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530-723) mL, expired tidal volume = 608 ± 36 (530-728) mL, peak pressure = 20.8 ± 2.3 (17.2-25.9) cmH(2)O, respiratory rate = 20.09 ± 0.35 (19.5-21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26-10.8) cmH(2)O, oxygen fraction = 0.49 ± 0.014 (0.41-0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.

  17. Hyperpolarized gas diffusion MRI for the study of atelectasis and acute respiratory distress syndrome.

    PubMed

    Cereda, Maurizio; Xin, Yi; Kadlecek, Stephen; Hamedani, Hooman; Rajaei, Jennia; Clapp, Justin; Rizi, Rahim R

    2014-12-01

    Considerable uncertainty remains about the best ventilator strategies for the mitigation of atelectasis and associated airspace stretch in patients with acute respiratory distress syndrome (ARDS). In addition to several immediate physiological effects, atelectasis increases the risk of ventilator-associated lung injury, which has been shown to significantly worsen ARDS outcomes. A number of lung imaging techniques have made substantial headway in clarifying the mechanisms of atelectasis. This paper reviews the contributions of computed tomography, positron emission tomography, and conventional MRI to understanding this phenomenon. In doing so, it also reveals several important shortcomings inherent to each of these approaches. Once these shortcomings have been made apparent, we describe how hyperpolarized (HP) gas MRI--a technique that is uniquely able to assess responses to mechanical ventilation and lung injury in peripheral airspaces--is poised to fill several of these knowledge gaps. The HP-MRI-derived apparent diffusion coefficient (ADC) quantifies the restriction of (3) He diffusion by peripheral airspaces, thereby obtaining pulmonary structural information at an extremely small scale. Lastly, this paper reports the results of a series of experiments that measured ADC in mechanically ventilated rats in order to investigate (i) the effect of atelectasis on ventilated airspaces, (ii) the relationship between positive end-expiratory pressure (PEEP), hysteresis, and the dimensions of peripheral airspaces, and (iii) the ability of PEEP and surfactant to reduce airspace dimensions after lung injury. An increase in ADC was found to be a marker of atelectasis-induced overdistension. With recruitment, higher airway pressures were shown to reduce stretch rather than worsen it. Moving forward, HP MRI has significant potential to shed further light on the atelectatic processes that occur during mechanical ventilation. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Analysis of a Pediatric Home Mechanical Ventilator Population.

    PubMed

    Amirnovin, Rambod; Aghamohammadi, Sara; Riley, Carley; Woo, Marlyn S; Del Castillo, Sylvia

    2018-05-01

    The population of children requiring home mechanical ventilation has evolved over the years and has grown to include a variety of diagnoses and needs that have led to changes in the care of this unique population. The purpose of this study was to provide a descriptive analysis of pediatric patients requiring home mechanical ventilation after hospitalization and how the evolution of this technology has impacted their care. A retrospective, observational, longitudinal analysis of 164 children enrolled in a university-affiliated home mechanical ventilation program over 26 years was performed. Data included each child's primary diagnosis, date of tracheostomy placement, duration of mechanical ventilation during hospitalization that consisted of home mechanical ventilator initiation, total length of pediatric ICU stay, ventilator settings at time of discharge from pediatric ICU, and disposition (home, facility, or died). Univariate, bivariate, and regression analysis was used as appropriate. The most common diagnosis requiring the use of home mechanical ventilation was neuromuscular disease (53%), followed by chronic pulmonary disease (29%). The median length of stay in the pediatric ICU decreased significantly after the implementation of a ventilator ward (70 d [30-142] vs 36 d [18-67], P = .02). The distribution of subjects upon discharge was home (71%), skilled nursing facility (24%), and died (4%), with an increase in the proportion of subjects discharged on PEEP and those going to nursing facilities over time ( P = 0.02). The evolution of home mechanical ventilation has allowed earlier transition out of the pediatric ICU and with increasing disposition to skilled nursing facilities over time. There has also been a change in ventilator management, including increased use of PEEP upon discharge, possibly driven by changes in ventilators and in-patient practice patterns. Copyright © 2018 by Daedalus Enterprises.

  19. The Society for Translational Medicine: clinical practice guidelines for mechanical ventilation management for patients undergoing lobectomy.

    PubMed

    Gao, Shugeng; Zhang, Zhongheng; Brunelli, Alessandro; Chen, Chang; Chen, Chun; Chen, Gang; Chen, Haiquan; Chen, Jin-Shing; Cassivi, Stephen; Chai, Ying; Downs, John B; Fang, Wentao; Fu, Xiangning; Garutti, Martínez I; He, Jianxing; He, Jie; Hu, Jian; Huang, Yunchao; Jiang, Gening; Jiang, Hongjing; Jiang, Zhongmin; Li, Danqing; Li, Gaofeng; Li, Hui; Li, Qiang; Li, Xiaofei; Li, Yin; Li, Zhijun; Liu, Chia-Chuan; Liu, Deruo; Liu, Lunxu; Liu, Yongyi; Ma, Haitao; Mao, Weimin; Mao, Yousheng; Mou, Juwei; Ng, Calvin Sze Hang; Petersen, René H; Qiao, Guibin; Rocco, Gaetano; Ruffini, Erico; Tan, Lijie; Tan, Qunyou; Tong, Tang; Wang, Haidong; Wang, Qun; Wang, Ruwen; Wang, Shumin; Xie, Deyao; Xue, Qi; Xue, Tao; Xu, Lin; Xu, Shidong; Xu, Songtao; Yan, Tiansheng; Yu, Fenglei; Yu, Zhentao; Zhang, Chunfang; Zhang, Lanjun; Zhang, Tao; Zhang, Xun; Zhao, Xiaojing; Zhao, Xuewei; Zhi, Xiuyi; Zhou, Qinghua

    2017-09-01

    Patients undergoing lobectomy are at significantly increased risk of lung injury. One-lung ventilation is the most commonly used technique to maintain ventilation and oxygenation during the operation. It is a challenge to choose an appropriate mechanical ventilation strategy to minimize the lung injury and other adverse clinical outcomes. In order to understand the available evidence, a systematic review was conducted including the following topics: (I) protective ventilation (PV); (II) mode of mechanical ventilation [e.g., volume controlled (VCV) versus pressure controlled (PCV)]; (III) use of therapeutic hypercapnia; (IV) use of alveolar recruitment (open-lung) strategy; (V) pre-and post-operative application of positive end expiratory pressure (PEEP); (VI) Inspired Oxygen concentration; (VII) Non-intubated thoracoscopic lobectomy; and (VIII) adjuvant pharmacologic options. The recommendations of class II are non-intubated thoracoscopic lobectomy may be an alternative to conventional one-lung ventilation in selected patients. The recommendations of class IIa are: (I) Therapeutic hypercapnia to maintain a partial pressure of carbon dioxide at 50-70 mmHg is reasonable for patients undergoing pulmonary lobectomy with one-lung ventilation; (II) PV with a tidal volume of 6 mL/kg and PEEP of 5 cmH 2 O are reasonable methods, based on current evidence; (III) alveolar recruitment [open lung ventilation (OLV)] may be beneficial in patients undergoing lobectomy with one-lung ventilation; (IV) PCV is recommended over VCV for patients undergoing lung resection; (V) pre- and post-operative CPAP can improve short-term oxygenation in patients undergoing lobectomy with one-lung ventilation; (VI) controlled mechanical ventilation with I:E ratio of 1:1 is reasonable in patients undergoing one-lung ventilation; (VII) use of lowest inspired oxygen concentration to maintain satisfactory arterial oxygen saturation is reasonable based on physiologic principles; (VIII) Adjuvant drugs

  20. [USE OF PROTECTIVE LUNG VENTILATION REGIMEN IN CARDIAC SURGERY PATIENTS.

    PubMed

    Pshenichniy, T A; Akselrod, B A; Titova, I V; Trekova, N A; Khrustaleva, M V

    2017-09-01

    In cardiac surgery, protective lung ventilation and/or preventive brdnchoscopy (PB) are able to decrease lung injury effects of cardiopulmonary bypass (CPB) and mechanical ventilation. define lung complication risks, evaluate the effect ofprotective lung ventilation (PLV) on lung functioning, and investigate the feasibility ofpreventive PB in higher pulmonary risk (PR) patients. 66 patients participated in prospective randomized research. Allocation was based on PR and intraoperative mechanical ventilation type. PLV includedfollowing parameters: PCK PIP - up to 20 cm H20, Vt - 6 ml/ kg of PBW, PEEP - 5-10 cm H20, IE ratio - 1:1.5-1:1, EtCO2 - 35-42 mm Hg, FiO2 - 45-60%, lung ventilation during CPB, alveolar recruitment. Four groups were formed: A - higher PR plus PLV- B - higher PR plus conventional LV (CLV), C - lower PR plus PLV- D - lower PR plus CLV PIP PEEP dynamic compliance, p/f ratio and intrapulmonary shunt (Qs/Qt) were recorded. Seventeen patients of group A underwent PB. Advanced dynamic compliance, higher p/f ratio and lower Qs/Qt were seen in group A, in comparison with group B (p< 0.05). Lower Qs/Qt was seen in group C, in comparison with group D (p<0.05). Mucus obstruction of subsegmental bronchi was observed in 53.3% of higher PR patients. More than half ofpatients without PB sufferedfrom postoperative lung complications (70.4 vs. 34.2 7%, p

  1. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

    PubMed

    Wallon, G; Bonnet, A; Guérin, C

    2013-06-01

    Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.

  2. Open lung approach vs acute respiratory distress syndrome network ventilation in experimental acute lung injury.

    PubMed

    Spieth, P M; Güldner, A; Carvalho, A R; Kasper, M; Pelosi, P; Uhlig, S; Koch, T; Gama de Abreu, M

    2011-09-01

    Setting and strategies of mechanical ventilation with positive end-expiratory pressure (PEEP) in acute lung injury (ALI) remains controversial. This study compares the effects between lung-protective mechanical ventilation according to the Acute Respiratory Distress Syndrome Network recommendations (ARDSnet) and the open lung approach (OLA) on pulmonary function and inflammatory response. Eighteen juvenile pigs were anaesthetized, mechanically ventilated, and instrumented. ALI was induced by surfactant washout. Animals were randomly assigned to mechanical ventilation according to the ARDSnet protocol or the OLA (n=9 per group). Gas exchange, haemodynamics, pulmonary blood flow (PBF) distribution, and respiratory mechanics were measured at intervals and the lungs were removed after 6 h of mechanical ventilation for further analysis. PEEP and mean airway pressure were higher in the OLA than in the ARDSnet group [15 cmH(2)O, range 14-18 cmH(2)O, compared with 12 cmH(2)O; 20.5 (sd 2.3) compared with 18 (1.4) cmH(2)O by the end of the experiment, respectively], and OLA was associated with improved oxygenation compared with the ARDSnet group after 6 h. OLA showed more alveolar overdistension, especially in gravitationally non-dependent regions, while the ARDSnet group was associated with more intra-alveolar haemorrhage. Inflammatory mediators and markers of lung parenchymal stress did not differ significantly between groups. The PBF shifted from ventral to dorsal during OLA compared with ARDSnet protocol [-0.02 (-0.09 to -0.01) compared with -0.08 (-0.12 to -0.06), dorsal-ventral gradients after 6 h, respectively]. According to the OLA, mechanical ventilation improved oxygenation and redistributed pulmonary perfusion when compared with the ARDSnet protocol, without differences in lung inflammatory response.

  3. Artificial neural networks can be effectively used to model changes of intracranial pressure (ICP) during spinal surgery using different non invasive ICP surrogate estimators.

    PubMed

    Watad, Abdulla; Bragazzi, Nicola L; Bacigaluppi, Susanna; Amital, Howard; Watad, Samaa; Sharif, Kassem; Bisharat, Bishara; Siri, Anna; Mahamid, Ala; Abu Ras, Hakim; Nasr, Ahmed; Bilotta, Federico; Robba, Chiara; Adawi, Mohammad

    2018-02-23

    Artificial Intelligence (AI) techniques play a major role in anesthesiology, even though their importance is often overlooked. In the extant literature, AI approaches, such as Artificial Neural Networks (ANNs), have been underutilized, mainly being used to model patient's consciousness state, to predict the precise amount of anesthetic gases, the level of analgesia, or the need of anesthesiological blocks, among others. In the field of neurosurgery, ANNs have been effectively applied to the diagnosis and prognosis of cerebral tumors, seizures, low back pain, and also to the monitoring of intracranial pressure (ICP). A MultiLayer Perceptron (MLP), which is a feedforward ANN, with hyperbolic tangent as activation function in the input/hidden layers, softmax as activation function in the output layer, and cross-entropy as error function, was used to model the impact of prone versus supine position and the use of positive end expiratory pressure (PEEP) on ICP in a sample of 30 patients undergoing spinal surgery. Different non invasive surrogate estimations of ICP have been used and compared: namely, mean optic nerve sheath diameter (ONSD), non invasive estimated cerebral perfusion pressure (NCPP), pulsatility index (PI), ICP derived from PI (ICP-PI), and flow velocity diastolic formula (FVDICP). ONSD proved to be a more robust surrogate estimation of ICP, with a predictive power of 75%, whilst the power of NCPP, ICP-PI, PI, and FVDICP were 60.5%, 54.8%, 53.1%, and 47.7%, respectively. Our MLP analysis confirmed our findings previously obtained with regression, correlation, multivariate Receiving Operator Curve (multi-ROC) analyses. ANNs can be successfully used to predict the effects of prone versus supine position and PEEP on ICP in patients undergoing spinal surgery using different non invasive surrogate estimators of ICP.

  4. Hyperpolarized Gas Diffusion MRI for the Study of Atelectasis and Acute Respiratory Distress Syndrome

    PubMed Central

    Cereda, Maurizio; Xin, Yi; Kadlecek, Stephen; Hamedani, Hooman; Rajaei, Jennia; Clapp, Justin; Rizi, Rahim R.

    2014-01-01

    Considerable uncertainty remains about the best ventilator strategies for the mitigation of atelectasis and associated airspace stretch in patients with acute respiratory distress syndrome (ARDS). In addition to several immediate physiological effects, atelectasis increases the risk of ventilator-associated lung injury (VALI), which has been shown to significantly worsen ARDS outcomes. A number of lung imaging techniques have made substantial headway in clarifying the mechanisms of atelectasis. This paper reviews the contributions of CT, PET, and conventional MRI to understanding this phenomenon. In doing so, it also reveals several important shortcomings inherent to each of these approaches. Once these shortcomings have been made apparent, we describe how hyperpolarized gas magnetic resonance imaging (HP MRI)—a technique that is uniquely able to assess responses to mechanical ventilation and lung injury in peripheral airspaces—is poised to fill several of these knowledge gaps. The HP-MRI-derived apparent diffusion coefficient (ADC) quantifies the restriction of 3He diffusion by peripheral airspaces, thereby obtaining pulmonary structural information at an extremely small scale. Lastly, this paper reports the results of a series of experiments that measured ADC in mechanically ventilated rats in order to investigate (i) the effect of atelectasis on ventilated airspaces; (ii) the relationship between positive end-expiratory pressure (PEEP), hysteresis, and the dimensions of peripheral airspaces; and (iii) the ability of PEEP and surfactant to reduce airspace dimensions after lung injury. An increase in ADC was found to be a marker of atelectasis-induced overdistension. With recruitment, higher airway pressures were shown to reduce stretch rather than worsen it. Moving forward, HP MRI has significant potential to shed further light on the atelectatic processes that occur during mechanical ventilation. PMID:24920074

  5. Feasibility and safety of low-flow extracorporeal CO2 removal managed with a renal replacement platform to enhance lung-protective ventilation of patients with mild-to-moderate ARDS.

    PubMed

    Schmidt, Matthieu; Jaber, Samir; Zogheib, Elie; Godet, Thomas; Capellier, Gilles; Combes, Alain

    2018-05-10

    Extracorporeal carbon-dioxide removal (ECCO 2 R) might allow ultraprotective mechanical ventilation with lower tidal volume (VT) (< 6 ml/kg predicted body weight), plateau pressure (P plat ) (< 30 cmH 2 O), and driving pressure to limit ventilator-induced lung injury. This study was undertaken to assess the feasibility and safety of ECCO 2 R managed with a renal replacement therapy (RRT) platform to enable very low tidal volume ventilation of patients with mild-to-moderate acute respiratory distress syndrome (ARDS). Twenty patients with mild (n = 8) or moderate (n = 12) ARDS were included. VT was gradually lowered from 6 to 5, 4.5, and 4 ml/kg, and PEEP adjusted to reach 23 ≤ P plat  ≤ 25 cmH 2 O. Standalone ECCO 2 R (no hemofilter associated with the RRT platform) was initiated when arterial PaCO 2 increased by > 20% from its initial value. Ventilation parameters (VT, respiratory rate, PEEP), respiratory system compliance, P plat and driving pressure, arterial blood gases, and ECCO 2 R-system operational characteristics were collected during at least 24 h of very low tidal volume ventilation. Complications, day-28 mortality, need for adjuvant therapies, and data on weaning off ECCO 2 R and mechanical ventilation were also recorded. While VT was reduced from 6 to 4 ml/kg and P plat kept < 25 cmH 2 O, PEEP was significantly increased from 13.4 ± 3.6 cmH 2 O at baseline to 15.0 ± 3.4 cmH 2 O, and the driving pressure was significantly reduced from 13.0 ± 4.8 to 7.9 ± 3.2 cmH 2 O (both p < 0.05). The PaO 2 /FiO 2 ratio and respiratory-system compliance were not modified after VT reduction. Mild respiratory acidosis occurred, with mean PaCO 2 increasing from 43 ± 8 to 53 ± 9 mmHg and mean pH decreasing from 7.39 ± 0.1 to 7.32 ± 0.10 from baseline to 4 ml/kg VT, while the respiratory rate was not altered. Mean extracorporeal blood flow, sweep-gas flow, and CO 2 removal were 421 ± 40

  6. [Implementation of modern trends in the methods of the ventilation support in the new apparatus for artificial lung ventilation Avenir-221 P].

    PubMed

    Gal'perin, Iu Sh; Alkhimova, L R; Dmitriev, N D; Kozlova, I A; Nemirovskiĭ, S B; Makarov, M V; Safronov, A Iu

    2005-01-01

    In the new ventilator Avenir-221 P modern lines of development of ventilation support in intensive therapy of adults and children are implemented. The capacities of the ventilator are successfully combined with its technical decisions which include microprocessor parametrical controlling, programming-controlled electric drive, an information saturation, intuitively clear control system, protection against interruption of power supply sources and oxygen feeding falls. A set of functional characteristics (modes VCV, PCV, Ass/Contr, PSV, SIMV, PEEP, Sigh, etc.) in combination with an original design make the device the most accessible and promising for application in intensive care and resuscitation units of a wide network of Russian hospitals and clinics. The ventilator Avenir-221 P has passed all required tests and is presently commercially available.

  7. A Peep into the Uncertainty-Complexity-Relevance Modeling Trilemma through Global Sensitivity and Uncertainty Analysis

    NASA Astrophysics Data System (ADS)

    Munoz-Carpena, R.; Muller, S. J.; Chu, M.; Kiker, G. A.; Perz, S. G.

    2014-12-01

    Model Model complexity resulting from the need to integrate environmental system components cannot be understated. In particular, additional emphasis is urgently needed on rational approaches to guide decision making through uncertainties surrounding the integrated system across decision-relevant scales. However, in spite of the difficulties that the consideration of modeling uncertainty represent for the decision process, it should not be avoided or the value and science behind the models will be undermined. These two issues; i.e., the need for coupled models that can answer the pertinent questions and the need for models that do so with sufficient certainty, are the key indicators of a model's relevance. Model relevance is inextricably linked with model complexity. Although model complexity has advanced greatly in recent years there has been little work to rigorously characterize the threshold of relevance in integrated and complex models. Formally assessing the relevance of the model in the face of increasing complexity would be valuable because there is growing unease among developers and users of complex models about the cumulative effects of various sources of uncertainty on model outputs. In particular, this issue has prompted doubt over whether the considerable effort going into further elaborating complex models will in fact yield the expected payback. New approaches have been proposed recently to evaluate the uncertainty-complexity-relevance modeling trilemma (Muller, Muñoz-Carpena and Kiker, 2011) by incorporating state-of-the-art global sensitivity and uncertainty analysis (GSA/UA) in every step of the model development so as to quantify not only the uncertainty introduced by the addition of new environmental components, but the effect that these new components have over existing components (interactions, non-linear responses). Outputs from the analysis can also be used to quantify system resilience (stability, alternative states, thresholds or tipping points) in the face of environmental and anthropogenic change (Perz, Muñoz-Carpena, Kiker and Holt, 2013), and through MonteCarlo mapping potential management activities over the most important factors or processes to influence the system towards behavioral (desirable) outcomes (Chu-Agor, Muñoz-Carpena et al., 2012).

  8. Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography.

    PubMed

    Hentze, Benjamin; Muders, Thomas; Luepschen, Henning; Maripuu, Enn; Hedenstierna, Göran; Putensen, Christian; Walter, Marian; Leonhardt, Steffen

    2018-06-20

    Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation ([Formula: see text]) in intensive care patients at bedside. However, for improved guidance of ventilation therapy it would be beneficial to obtain regional ventilation-to-perfusion ratio ([Formula: see text]) by EIT. In order to further explore the feasibility, we first evaluate a model-based approach, based on semi-negative matrix factorization and a gamma-variate model, to extract regional lung perfusion ([Formula: see text]) from EIT measurements. Subsequently, a combined validation of both [Formula: see text] and [Formula: see text] measured by EIT against single-photon emission computed tomography (SPECT) is performed on data acquired as part of a porcine animal trial. Four pigs were ventilated at two different levels of positive end-expiratory pressure (PEEP 0 and 15 cm H 2 O, respectively) in randomized order. Repeated injections of an EIT contrast agent (NaCl 10%) and simultaneous SPECT measurements of [Formula: see text] (81 m Kr gas) and [Formula: see text] (99 m Tc-labeled albumin) were performed. Both [Formula: see text] and [Formula: see text] from EIT and SPECT were compared by correlation analysis. Very strong (r 2   =  0.94 to 0.95) correlations were found for [Formula: see text] and [Formula: see text] in the dorsal-ventral direction at both PEEP levels. Moderate (r 2   =  0.36 to 0.46) and moderate to strong (r 2   =  0.61 to 0.82) correlations resulted for [Formula: see text] and [Formula: see text] in the right-left direction, respectively. The results of combined validation indicate that monitoring of [Formula: see text] and [Formula: see text] by EIT is possible. However, care should be taken when trying to quantify [Formula: see text] by EIT, as imaging artefacts and model bias may void necessary spatial matching.

  9. Monitoring of intrathoracic volemia and cardiac output in critically ill children.

    PubMed

    Cecchetti, C; Stoppa, F; Vanacore, N; Barbieri, M A; Raucci, U; Pasotti, E; Tomasello, C; Marano, M; Pirozzi, N

    2003-12-01

    Hemodynamic monitoring is an important step in the management of critically ill children despite the difficulty in measuring preload indices continuously. The aim of the study was to analyze cardiac output parameters and preload indices after acute changes in mean airway pressure and volemia. Twenty-three children treated at our unit were enrolled in a prospective non randomized cohort study. Respiration was supported by controlled mechanical ventilation with positive expiratory-end pressure (PEEP), peak inspiratory pressure <20 cm H(2)O and mean airway pressure <10 cm H(2)O, and hemodynamic monitoring using the PiCCO system. Hemodynamic parameters were measured at T0 (base line), T(1) (after an increase in PEEP of 5 cm H(2)O for 10 min), and T(2) (after fluid challenge). The statistical analysis (BMPD New System software package) comprised comparison of changes at T(0) vs T(1), T(1) vs T(2) and T(0) vs T(2), construction of 3 correlation matrices and multiple linear regression analysis. Sixty-nine hemodynamic parameters were measured in the 23 patients. A comparison between T(0) and T(1) showed no significant changes; differences between T(0) and T(2) were found for cardiac index (CI), (p=0.003); between T(0) and T(2) significant differences were found for CI (p=0.0015), intrathoracic blood volume index (ITBVI) (p=0.04) and stroke volume index (SVI) (p=0.06). The analysis of the correlation matrices yielded ITBVI with CI (p=0.0006), ITBVI with SVI (p=1 x 10(-5)), CI with SVI (p=0.002); a significant correlation between CI and extravascular lung water index (EVLWI) was found only at T(1). Multiple linear regression analysis showed that ITBVI and SVI were predictive for variance of CI at each time point. ITBVI measured by a volumetric monitoring system such as the PiCCO may be considered a sensitive preload indicator also in critically ill children.

  10. Early Detection of Ventilation-Induced Brain Injury Using Magnetic Resonance Spectroscopy and Diffusion Tensor Imaging: An In Vivo Study in Preterm Lambs

    PubMed Central

    Skiöld, Béatrice; Wu, Qizhu; Hooper, Stuart B.; Davis, Peter G.; McIntyre, Richard; Tolcos, Mary; Pearson, James; Vreys, Ruth; Egan, Gary F.; Barton, Samantha K.; Cheong, Jeanie L. Y.; Polglase, Graeme R.

    2014-01-01

    Background and Aim High tidal volume (VT) ventilation during resuscitation of preterm lambs results in brain injury evident histologically within hours after birth. We aimed to investigate whether magnetic resonance spectroscopy (MRS) and/or diffusion tensor imaging (DTI) can be used for early in vivo detection of ventilation-induced brain injury in preterm lambs. Methods Newborn lambs (0.85 gestation) were stabilized with a “protective ventilation” strategy (PROT, n = 7: prophylactic Curosurf, sustained inflation, VT 7 mL/kg, positive end expiratory pressure (PEEP) 5 cmH2O) or an initial 15 minutes of “injurious ventilation” (INJ, n = 10: VT 12 mL/kg, no PEEP, late Curosurf) followed by PROT ventilation for the remainder of the experiment. At 1 hour, lambs underwent structural magnetic resonance imaging (Siemens, 3 Tesla). For measures of mean/axial/radial diffusivity (MD, AD, RD) and fractional anisotropy (FA), 30 direction DTI was performed. Regions of interests encompassed the thalamus, internal capsule, periventricular white matter and the cerebellar vermis. MRS was performed using a localized single-voxel (15×15×20 mm3, echo time 270 ms) encompassing suptratentorial deep nuclear grey matter and central white matter. Peak-area ratios for lactate (Lac) relative to N-acetylaspartate (NAA), choline (Cho) and creatine (Cr) were calculated. Groups were compared using 2-way RM-ANOVA, Mann-Whitney U-test and Spearman's correlations. Results No cerebral injury was seen on structural MR images. Lambs in the INJ group had higher mean FA and lower mean RD in the thalamus compared to PROT lambs, but not in the other regions of interest. Peak-area lactate ratios >1.0 was only seen in INJ lambs. A trend of higher mean peak-area ratios for Lac/Cr and Lac/Cho was seen, which correlated with lower pH in both groups. Conclusion Acute changes in brain diffusion measures and metabolite peak-area ratios were observed after injurious ventilation. Early MRS/DTI is

  11. A universal definition of ARDS: the PaO2/FiO2 ratio under a standard ventilatory setting--a prospective, multicenter validation study.

    PubMed

    Villar, Jesús; Pérez-Méndez, Lina; Blanco, Jesús; Añón, José Manuel; Blanch, Lluís; Belda, Javier; Santos-Bouza, Antonio; Fernández, Rosa Lidia; Kacmarek, Robert M

    2013-04-01

    The PaO2/FiO2 is an integral part of the assessment of patients with acute respiratory distress syndrome (ARDS). The American-European Consensus Conference definition does not mandate any standardization procedure. We hypothesized that the use of PaO2/FiO2 calculated under a standard ventilatory setting within 24 h of ARDS diagnosis allows a more clinically relevant ARDS classification. We studied 452 ARDS patients enrolled prospectively in two independent, multicenter cohorts treated with protective mechanical ventilation. At the time of ARDS diagnosis, patients had a PaO2/FiO2 ≤ 200. In the derivation cohort (n = 170), we measured PaO2/FiO2 with two levels of positive end-expiratory pressure (PEEP) (≥ 5 and ≥ 10 cmH2O) and two levels of FiO2 (≥ 0.5 and 1.0) at ARDS onset and 24 h later. Dependent upon PaO2 response, patients were reclassified into three groups: mild (PaO2/FiO2 > 200), moderate (PaO2/FiO2 101-200), and severe (PaO2/FiO2 ≤ 100) ARDS. The primary outcome measure was ICU mortality. The standard ventilatory setting that reached the highest significance difference in mortality among these categories was tested in a separate cohort (n = 282). The only standard ventilatory setting that identified the three PaO2/FiO2 risk categories in the derivation cohort was PEEP ≥ 10 cmH2O and FiO2 ≥ 0.5 at 24 h after ARDS onset (p = 0.0001). Using this ventilatory setting, patients in the validation cohort were reclassified as having mild ARDS (n = 47, mortality 17 %), moderate ARDS (n = 149, mortality 40.9 %), and severe ARDS (n = 86, mortality 58.1 %) (p = 0.00001). Our method for assessing PaO2/FiO2 greatly improved risk stratification of ARDS and could be used for enrolling appropriate ARDS patients into therapeutic clinical trials.

  12. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    PubMed

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    PubMed

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  14. The Society for Translational Medicine: clinical practice guidelines for mechanical ventilation management for patients undergoing lobectomy

    PubMed Central

    Zhang, Zhongheng; Brunelli, Alessandro; Chen, Chang; Chen, Chun; Chen, Gang; Chen, Haiquan; Chen, Jin-Shing; Cassivi, Stephen; Chai, Ying; Downs, John B.; Fang, Wentao; Fu, Xiangning; Garutti, Martínez I.; He, Jianxing; Hu, Jian; Huang, Yunchao; Jiang, Gening; Jiang, Hongjing; Jiang, Zhongmin; Li, Danqing; Li, Gaofeng; Li, Hui; Li, Qiang; Li, Xiaofei; Li, Yin; Li, Zhijun; Liu, Chia-Chuan; Liu, Deruo; Liu, Lunxu; Liu, Yongyi; Ma, Haitao; Mao, Weimin; Mao, Yousheng; Mou, Juwei; Ng, Calvin Sze Hang; Petersen, René H.; Qiao, Guibin; Rocco, Gaetano; Ruffini, Erico; Tan, Lijie; Tan, Qunyou; Tong, Tang; Wang, Haidong; Wang, Qun; Wang, Ruwen; Wang, Shumin; Xie, Deyao; Xue, Qi; Xue, Tao; Xu, Lin; Xu, Shidong; Xu, Songtao; Yan, Tiansheng; Yu, Fenglei; Yu, Zhentao; Zhang, Chunfang; Zhang, Lanjun; Zhang, Tao; Zhang, Xun; Zhao, Xiaojing; Zhao, Xuewei; Zhi, Xiuyi; Zhou, Qinghua

    2017-01-01

    Patients undergoing lobectomy are at significantly increased risk of lung injury. One-lung ventilation is the most commonly used technique to maintain ventilation and oxygenation during the operation. It is a challenge to choose an appropriate mechanical ventilation strategy to minimize the lung injury and other adverse clinical outcomes. In order to understand the available evidence, a systematic review was conducted including the following topics: (I) protective ventilation (PV); (II) mode of mechanical ventilation [e.g., volume controlled (VCV) versus pressure controlled (PCV)]; (III) use of therapeutic hypercapnia; (IV) use of alveolar recruitment (open-lung) strategy; (V) pre-and post-operative application of positive end expiratory pressure (PEEP); (VI) Inspired Oxygen concentration; (VII) Non-intubated thoracoscopic lobectomy; and (VIII) adjuvant pharmacologic options. The recommendations of class II are non-intubated thoracoscopic lobectomy may be an alternative to conventional one-lung ventilation in selected patients. The recommendations of class IIa are: (I) Therapeutic hypercapnia to maintain a partial pressure of carbon dioxide at 50–70 mmHg is reasonable for patients undergoing pulmonary lobectomy with one-lung ventilation; (II) PV with a tidal volume of 6 mL/kg and PEEP of 5 cmH2O are reasonable methods, based on current evidence; (III) alveolar recruitment [open lung ventilation (OLV)] may be beneficial in patients undergoing lobectomy with one-lung ventilation; (IV) PCV is recommended over VCV for patients undergoing lung resection; (V) pre- and post-operative CPAP can improve short-term oxygenation in patients undergoing lobectomy with one-lung ventilation; (VI) controlled mechanical ventilation with I:E ratio of 1:1 is reasonable in patients undergoing one-lung ventilation; (VII) use of lowest inspired oxygen concentration to maintain satisfactory arterial oxygen saturation is reasonable based on physiologic principles; (VIII) Adjuvant drugs

  15. Lung-protective Ventilation in Patients with Brain Injury: A Multicenter Cross-sectional Study and Questionnaire Survey in China

    PubMed Central

    Luo, Xu-Ying; Hu, Ying-Hong; Cao, Xiang-Yuan; Kang, Yan; Liu, Li-Ping; Wang, Shou-Hong; Yu, Rong-Guo; Yu, Xiang-You; Zhang, Xia; Li, Bao-Shan; Ma, Zeng-Xiang; Weng, Yi-Bing; Zhang, Heng; Chen, De-Chang; Chen, Wei; Chen, Wen-Jin; Chen, Xiu-Mei; Du, Bin; Duan, Mei-Li; Hu, Jin; Huang, Yun-Feng; Jia, Gui-Jun; Li, Li-Hong; Liang, Yu-Min; Qin, Bing-Yu; Wang, Xian-Dong; Xiong, Jian; Yan, Li-Mei; Yang, Zheng-Ping; Dong, Chen-Ming; Wang, Dong-Xin; Zhan, Qing-Yuan; Fu, Shuang-Lin; Zhao, Lin; Huang, Qi-Bing; Xie, Ying-Guang; Huang, Xiao-Bo; Zhang, Guo-Bin; Xu, Wang-Bin; Xu, Yuan; Liu, Ya-Ling; Zhao, He-Ling; Sun, Rong-Qing; Sun, Ming; Cheng, Qing-Hong; Qu, Xin; Yang, Xiao-Feng; Xu, Ming; Shi, Zhong-Hua; Chen, Han; He, Xuan; Yang, Yan-Lin; Chen, Guang-Qiang; Sun, Xiu-Mei; Zhou, Jian-Xin

    2016-01-01

    Background: Over the years, the mechanical ventilation (MV) strategy has changed worldwide. The aim of the present study was to describe the ventilation practices, particularly lung-protective ventilation (LPV), among brain-injured patients in China. Methods: This study was a multicenter, 1-day, cross-sectional study in 47 Intensive Care Units (ICUs) across China. Mechanically ventilated patients (18 years and older) with brain injury in a participating ICU during the time of the study, including traumatic brain injury, stroke, postoperation with intracranial tumor, hypoxic-ischemic encephalopathy, intracranial infection, and idiopathic epilepsy, were enrolled. Demographic data, primary diagnoses, indications for MV, MV modes and settings, and prognoses on the 60th day were collected. Multivariable logistic analysis was used to assess factors that might affect the use of LPV. Results: A total of 104 patients were enrolled in the present study, 87 (83.7%) of whom were identified with severe brain injury based on a Glasgow Coma Scale ≤8 points. Synchronized intermittent mandatory ventilation (SIMV) was the most frequent ventilator mode, accounting for 46.2% of the entire cohort. The median tidal volume was set to 8.0 ml/kg (interquartile range [IQR], 7.0–8.9 ml/kg) of the predicted body weight; 50 (48.1%) patients received LPV. The median positive end-expiratory pressure (PEEP) was set to 5 cmH2O (IQR, 5–6 cmH2O). No PEEP values were higher than 10 cmH2O. Compared with partially mandatory ventilation, supportive and spontaneous ventilation practices were associated with LPV. There were no significant differences in mortality and MV duration between patients subjected to LPV and those were not. Conclusions: Among brain-injured patients in China, SIMV was the most frequent ventilation mode. Nearly one-half of the brain-injured patients received LPV. Patients under supportive and spontaneous ventilation were more likely to receive LPV. Trial Registration: Clinical

  16. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    PubMed

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p < 0.001). There were no detrimental effects in terms of lung mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  17. Recurrent Recruitment Manoeuvres Improve Lung Mechanics and Minimize Lung Injury during Mechanical Ventilation of Healthy Mice

    PubMed Central

    Reiss, Lucy Kathleen; Kowallik, Anke; Uhlig, Stefan

    2011-01-01

    Introduction Mechanical ventilation (MV) of mice is increasingly required in experimental studies, but the conditions that allow stable ventilation of mice over several hours have not yet been fully defined. In addition, most previous studies documented vital parameters and lung mechanics only incompletely. The aim of the present study was to establish experimental conditions that keep these parameters within their physiological range over a period of 6 h. For this purpose, we also examined the effects of frequent short recruitment manoeuvres (RM) in healthy mice. Methods Mice were ventilated at low tidal volume VT = 8 mL/kg or high tidal volume VT = 16 mL/kg and a positive end-expiratory pressure (PEEP) of 2 or 6 cmH2O. RM were performed every 5 min, 60 min or not at all. Lung mechanics were followed by the forced oscillation technique. Blood pressure (BP), electrocardiogram (ECG), heart frequency (HF), oxygen saturation and body temperature were monitored. Blood gases, neutrophil-recruitment, microvascular permeability and pro-inflammatory cytokines in bronchoalveolar lavage (BAL) and blood serum as well as histopathology of the lung were examined. Results MV with repetitive RM every 5 min resulted in stable respiratory mechanics. Ventilation without RM worsened lung mechanics due to alveolar collapse, leading to impaired gas exchange. HF and BP were affected by anaesthesia, but not by ventilation. Microvascular permeability was highest in atelectatic lungs, whereas neutrophil-recruitment and structural changes were strongest in lungs ventilated with high tidal volume. The cytokines IL-6 and KC, but neither TNF nor IP-10, were elevated in the BAL and serum of all ventilated mice and were reduced by recurrent RM. Lung mechanics, oxygenation and pulmonary inflammation were improved by increased PEEP. Conclusions Recurrent RM maintain lung mechanics in their physiological range during low tidal volume ventilation of healthy mice by preventing atelectasis and

  18. Non-invasive positive-pressure ventilation with positive end-expiratory pressure counteracts inward air leaks during preoxygenation: a randomised crossover controlled study in healthy volunteers.

    PubMed

    Hanouz, J-L; Le Gall, F; Gérard, J-L; Terzi, N; Normand, H

    2018-04-01

    During preoxygenation, the lack of tight fit between the mask and the patient's face results in inward air leak preventing effective preoxygenation. We hypothesized that non-invasive positive-pressure ventilation and positive end-expiratory pressure (PEEP) could counteract inward air leak. Healthy volunteers were randomly assigned to preoxygenated through spontaneous breathing without leak (SB), spontaneous breathing with a calibrated air leak (T-shaped piece between the mouth and the breathing system; SB-leak), or non-invasive positive inspiratory pressure ventilation (inspiratory support +6 cm H 2 O; PEEP +5 cm H 2 O) with calibrated leak (PPV-leak). The volunteers breathed through a mouthpiece connected to an anaesthesia ventilator. The expired oxygen fraction (FeO 2 ) and air-leak flow (ml s -1 ) were measured. The primary end point was the proportion of volunteers with FeO 2 >90% at 3 min. The secondary end points were FeO 2 at 3 min, time to reach FeO 2 of 90%, and the inspiratory air-leak flow. Twenty healthy volunteers were included. The proportion of volunteers with FeO 2 >90% at 3 min was 0% in the SB-leak group, 95% in the SB group, and 100% in the PPV-leak group (P<0.001). At 3 min, the mean [standard deviation (sd)] FeO 2 was 89 (1)%, 76 (1)%, and 90 (0)% in the SB, SB-leak, and PPV-leak groups, respectively (P<0.001). The mean (sd) inward air leak was 59 (12) ml s -1 in the SB-leak group, but 0 (0) ml s -1 in the PPV-leak group (P<0.001). Preoxygenation through non-invasive positive-pressure ventilation and PEEP provided effective preoxygenation despite an inward air leak. NCT03087825. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  19. Quantification of asymmetric lung pathophysiology as a guide to the use of simultaneous independent lung ventilation in posttraumatic and septic adult respiratory distress syndrome.

    PubMed Central

    Siegel, J H; Stoklosa, J C; Borg, U; Wiles, C E; Sganga, G; Geisler, F H; Belzberg, H; Wedel, S; Blevins, S; Goh, K C

    1985-01-01

    The management of impaired respiratory gas exchange in patients with nonuniform posttraumatic and septic adult respiratory distress syndrome (ARDS) contains its own therapeutic paradox, since the need for volume-controlled ventilation and PEEP in the lung with the most reduced compliance increases pulmonary barotrauma to the better lung. A computer-based system has been developed by which respiratory pressure-flow-volume relations and gas exchange characteristics can be obtained and respiratory dynamic and static compliance curves computed and displayed for each lung, as a means of evaluating the effectiveness of ventilation therapy in ARDS. Using these techniques, eight patients with asymmetrical posttraumatic or septic ARDS, or both, have been managed using simultaneous independent lung ventilation (SILV). The computer assessment technique allows quantification of the nonuniform ARDS pattern between the two lungs. This enabled SILV to be utilized using two synchronized servo-ventilators at different pressure-flow-volumes, inspiratory/expiratory ratios, and PEEP settings to optimize the ventilatory volumes and gas exchange of each lung, without inducing excess barotrauma in the better lung. In the patients with nonuniform ARDS, conventional ventilation was not effective in reducing shunt (QS/QT) or in permitting a lower FIO2 to be used for maintenance of an acceptable PaO2. SILV reduced per cent v-a shunt and permitted a higher PaO2 at lower FIO2. Also, there was x-ray evidence of ARDS improvement in the poorer lung. While the ultimate outcome was largely dependent on the patient's injury and the adequacy of the septic host defense, by utilizing the SILV technique to match the quantitative aspects of respiratory dysfunction in each lung at specific times in the clinical course, it was possible to optimize gas exchange, to reduce barotrauma, and often to reverse apparently fixed ARDS changes. In some instances, this type of physiologically directed ventilatory

  20. Driving pressure and mechanical power: new targets for VILI prevention.

    PubMed

    Tonetti, Tommaso; Vasques, Francesco; Rapetti, Francesca; Maiolo, Giorgia; Collino, Francesca; Romitti, Federica; Camporota, Luigi; Cressoni, Massimo; Cadringher, Paolo; Quintel, Michael; Gattinoni, Luciano

    2017-07-01

    Several factors have been recognized as possible triggers of ventilator-induced lung injury (VILI). The first is pressure (thus the 'barotrauma'), then the volume (hence the 'volutrauma'), finally the cyclic opening-closing of the lung units ('atelectrauma'). Less attention has been paid to the respiratory rate and the flow, although both theoretical considerations and experimental evidence attribute them a significant role in the generation of VILI. The initial injury to the lung parenchyma is necessarily mechanical and it could manifest as an unphysiological distortion of the extracellular matrix and/or as micro-fractures in the hyaluronan, likely the most fragile polymer embedded in the matrix. The order of magnitude of the energy required to break a molecular bond between the hyaluronan and the associated protein is 1.12×10 -16 Joules (J), 70-90% higher than the average energy delivered by a single breath of 1L assuming a lung elastance of 10 cmH 2 O/L (0.5 J). With a normal statistical distribution of the bond strength some polymers will be exposed each cycle to an energy large enough to rupture. Both the extracellular matrix distortion and the polymer fractures lead to inflammatory increase of capillary permeability with edema if a pulmonary blood flow is sufficient. The mediation analysis of higher vs. lower tidal volume and PEEP studies suggests that the driving pressure, more than tidal volume, is the best predictor of VILI, as inferred by increased mortality. This is not surprising, as both tidal volume and respiratory system elastance (resulting in driving pressure) may independently contribute to the mortality. For the same elastance driving pressure is a predictor similar to plateau pressure or tidal volume. Driving pressure is one of the components of the mechanical power, which also includes respiratory rate, flow and PEEP. Finding the threshold for mechanical power would greatly simplify assessment and prevention of VILI.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massa, Christopher B.; Scott, Pamela; Abramova, Elena

    Acute Cl{sub 2} exposure following industrial accidents or military/terrorist activity causes pulmonary injury and severe acute respiratory distress. Prior studies suggest that antioxidant depletion is important in producing dysfunction, however a pathophysiologic mechanism has not been elucidated. We propose that acute Cl{sub 2} inhalation leads to oxidative modification of lung lining fluid, producing surfactant inactivation, inflammation and mechanical respiratory dysfunction at the organ level. C57BL/6J mice underwent whole-body exposure to an effective 60 ppm-hour Cl{sub 2} dose, and were euthanized 3, 24 and 48 h later. Whereas pulmonary architecture and endothelial barrier function were preserved, transient neutrophilia, peaking at 24more » h, was noted. Increased expression of ARG1, CCL2, RETLNA, IL-1b, and PTGS2 genes was observed in bronchoalveolar lavage (BAL) cells with peak change in all genes at 24 h. Cl{sub 2} exposure had no effect on NOS2 mRNA or iNOS protein expression, nor on BAL NO{sub 3}{sup −} or NO{sub 2}{sup −}. Expression of the alternative macrophage activation markers, Relm-α and mannose receptor was increased in alveolar macrophages and pulmonary epithelium. Capillary surfactometry demonstrated impaired surfactant function, and altered BAL phospholipid and surfactant protein content following exposure. Organ level respiratory function was assessed by forced oscillation technique at 5 end expiratory pressures. Cl{sub 2} exposure had no significant effect on either airway or tissue resistance. Pulmonary elastance was elevated with time following exposure and demonstrated PEEP refractory derecruitment at 48 h, despite waning inflammation. These data support a role for surfactant inactivation as a physiologic mechanism underlying respiratory dysfunction following Cl{sub 2} inhalation. - Highlights: • Effect of 60 ppm*hr Cl{sub 2} gas on lung inflammation and mechanical function examined. • Pulmonary inflammation is transient and

  2. A new physiological model for studying the effect of chest compression and ventilation during cardiopulmonary resuscitation: The Thiel cadaver.

    PubMed

    Charbonney, Emmanuel; Delisle, Stéphane; Savary, Dominique; Bronchti, Gilles; Rigollot, Marceau; Drouet, Adrien; Badat, Bilal; Ouellet, Paul; Gosselin, Patrice; Mercat, Alain; Brochard, Laurent; Richard, Jean-Christophe M

    2018-04-01

    Studying ventilation and intrathoracic pressure (ITP) induced by chest compressions (CC) during Cardio Pulmonary Resuscitation is challenging and important aspects such as airway closure have been mostly ignored. We hypothesized that Thiel Embalmed Cadavers could constitute an appropriate model. We assessed respiratory mechanics and ITP during CC in 11 cadavers, and we compared it to measurements obtained in 9 out-of-hospital cardiac arrest patients and to predicted values from a bench model. An oesophageal catheter was inserted to assess chest wall compliance, and ITP variation (ΔITP). Airway pressure variation (ΔPaw) at airway opening and ΔITP generated by CC were measured at decremental positive end expiratory pressure (PEEP) to test its impact on flow and ΔPaw. The patient's data were derived from flow and airway pressure captured via the ventilator during resuscitation. Resistance and Compliance of the respiratory system were comparable to those of the out-of-hospital cardiac arrest patients (C RS TEC 42 ± 12 vs C RS PAT 37.3 ± 10.9 mL/cmH 2 O and Res TEC 17.5 ± 7.5 vs Res PAT 20.2 ± 5.3 cmH 2 O/L/sec), and remained stable over time. During CC, ΔITP varied from 32 ± 12 cmH 2 O to 69 ± 14 cmH 2 O with manual and automatic CC respectively. Transmission of ΔITP at the airway opening was significantly affected by PEEP, suggesting dynamic small airway closure at low lung volumes. This phenomenon was similarly observed in patients. Respiratory mechanics and dynamic pressures during CC of cadavers behave as predicted by a theoretical model and similarly to patients. The Thiel model is a suitable to assess ITP variations induced by ventilation during CC. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Rescue therapeutic strategy combining ultra-protective mechanical ventilation with extracorporeal CO2 removal membrane in near-fatal asthma with severe pulmonary barotraumas: A case report.

    PubMed

    Pavot, Arthur; Mallat, Jihad; Vangrunderbeeck, Nicolas; Thevenin, Didier; Lemyze, Malcolm

    2017-10-01

    Mechanical ventilation of severe acute asthma is still considered a challenging issue, mainly because of the gas trapping phenomenon with the potential for life-threatening barotraumatic pulmonary complications. Herein, we describe 2 consecutive cases of near-fatal asthma for whom the recommended protective mechanical ventilation approach using low tidal volume of 6 mL/kg and small levels of PEEP was rapidly compromised by giant pneumomediastinum with extensive subcutaneousemphysema. Near fatal asthma. A rescue therapeutic strategy combining extracorporeal CO2 removal membrane with ultra-protective extremely low tidal volume (3 mL/kg) ventilation was applied. Both patients survived hospital discharge. These 2 cases indicate that ECCO2R associated with ultra-protective ventilation could be an alternative to surgery in case of life-threatening barotrauma occurring under mechanical ventilation.

  4. KEEN Wave Simulations: Comparing various PIC to various fixed grid Vlasov to Phase-Space Adaptive Sparse Tiling & Effective Lagrangian (PASTEL) Techniques

    NASA Astrophysics Data System (ADS)

    Afeyan, Bedros; Larson, David; Shadwick, Bradley; Sydora, Richard

    2017-10-01

    We compare various ways of solving the Vlasov-Poisson and Vlasov-Maxwell equations on rather demanding nonlinear kinetic phenomena associated with KEEN and KEEPN waves. KEEN stands for Kinetic, Electrostatic, Electron Nonlinear, and KEEPN, for electron-positron or pair plasmas analogs. Because these self-organized phase space structures are not steady-state, or single mode, or fluid or low order moment equation limited, typical techniques with low resolution or too much noise will distort the answer too much, too soon, and fail. This will be shown via Penrose criteria triggers for instability at the formation stage as well as particle orbit statistics in fully formed KEEN waves and KEEN-KEEN and KEEN-EPW interacting states. We will argue that PASTEL is a viable alternative to traditional methods with reasonable chances of success in higher dimensions. Work supported by a Grant from AFOSR PEEP.

  5. Act on Gender: A Peep into Intra-Household Water Use in the Australian Capital Territory (ACT) Region

    ERIC Educational Resources Information Center

    Lahiri-Dutt, Kuntala; Harriden, Kate

    2008-01-01

    Intra-household water use and management from a gender perspective has remained a relatively under-researched theme in developed countries. Australia is no exception, with the lack of research particularly evident in the many rural and peri-urban communities. These communities have experienced significant water scarcity in recent years. In this…

  6. Post- thyroidectomy haematoma causing severe supraglottic oedema and pulmonary oedema - a case report.

    PubMed

    Parate, Leena Harshad; Pujari, Vinayak Seenappa; Anandaswamy, Tejesh C; Vig, Saurabh

    2014-08-01

    Large, long standing goiters present multiple challenges to anaesthesiologist. Post thyroidectomy haematoma is a rare but life threatening complication of thyroid surgery leading to airway obstruction. We report a case of huge goiter that underwent near total thyroidectomy and developed post thyroidectomy haematoma. Within no time it resulted in near fatal airway obstruction, pulmonary oedema and cardiac arrest. The haematoma was evacuated immediately and patient was resuscitated successfully. Pulmonary oedema was further worsened by subsequent aggressive fluid resuscitation. She was electively ventilated with PEEP and was extubated after five days. Except for right vocal cord palsy her postoperative stay was uneventful. This is unique case where a post thyoidectomy haematoma has resulted in fatal supraglottic oedema and pulmonary oedema. Early recognition, immediate intubation and evacuation of haematoma are the key to manage this complication. We highlight on the pathophysiology of haematoma and discuss the strategies to prevent similar events in future.

  7. Electrical impedance tomography

    PubMed Central

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  8. [Concepts and monitoring of pulmonary mechanic in patients under ventilatory support in intensive care unit].

    PubMed

    Faustino, Eduardo Antonio

    2007-06-01

    In mechanical ventilation, invasive and noninvasive, the knowledge of respiratory mechanic physiology is indispensable to take decisions and into the efficient management of modern ventilators. Monitoring of pulmonary mechanic parameters is been recommended from all the review works and clinical research. The objective of this study was review concepts of pulmonary mechanic and the methods used to obtain measures in the bed side, preparing a rational sequence to obtain this data. It was obtained bibliographic review through data bank LILACS, MedLine and PubMed, from the last ten years. This review approaches parameters of resistance, pulmonary compliance and intrinsic PEEP as primordial into comprehension of acute respiratory failure and mechanic ventilatory support, mainly in acute respiratory distress syndrome (ARDS) and in chronic obstructive pulmonary disease (COPD). Monitoring pulmonary mechanics in patients under mechanical ventilation in intensive care units gives relevant informations and should be implemented in a rational and systematic way.

  9. Altitudinal distribution and advertisement call of Colostethus latinasus (Amphibia: Dendrobatidae), endemic species from eastern Panama and type species of Colostethus , with a molecular assessment of similar sympatric species.

    PubMed

    Ibáñez, Roberto D; Griffith, Edgardo J; Lips, Karen R; Crawford, Andrew J

    2017-04-12

    We conducted a molecular assessment of Colostethus-like frogs along an elevational gradient in the Serranía de Pirre, above Santa Cruz de Cana, eastern Panama, aiming to establish their species identity and to determine the altitudinal distribution of C. latinasus. Our findings confirm the view of C. latinasus as an endemic species restricted to the highlands of this mountain range, i.e., 1350-1475 m.a.s.l., considered to be type locality of this species. We described the advertisement call of C. latinasus that consists of a series of 4-18 single, short and relatively loud "peep"-like notes given in rapid succession, and its spectral and temporal features were compared with calls of congeneric species. For the first time, DNA sequences from C. latinasus were obtained, since previously reported sequences were based on misidentified specimens. This is particularly important because C. latinasus is the type species of Colostethus, a genus considered paraphyletic according to recent phylogenetic analyses based on molecular data.

  10. Dynamic Determination of Oxygenation and Lung Compliance in Murine Pneumonectomy

    PubMed Central

    Gibney, Barry; Lee, Grace S.; Houdek, Jan; Lin, Miao; Miele, Lino; Chamoto, Kenji; Konerding, Moritz A.; Tsuda, Akira; Mentzer, Steven J.

    2012-01-01

    Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, we investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55–82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10ml/kg. Sustained inflation pressures, referred to as a "recruitment maneuver," improved lung volumes, lung compliance and arterial oxygenation. In contrast, positive end expiratory pressure (PEEP) had a detrimental effect on oxygenation; an effect that was ameliorated after pneumonectomy. Our results confirm that lung volumes in the mouse are dynamically determined and suggest a threshold level of mechanical ventilation to maintain perioperative oxygen saturation. PMID:21574875

  11. To peep into Pif1 helicase: multifaceted all the way from genome stability to repair-associated DNA synthesis.

    PubMed

    Chung, Woo-Hyun

    2014-02-01

    Pif1 DNA helicase is the prototypical member of a 5' to 3' helicase superfamily conserved from bacteria to humans. In Saccharomyces cerevisiae, Pif1 and its homologue Rrm3, localize in both mitochondria and nucleus playing multiple roles in the maintenance of genomic homeostasis. They display relatively weak processivities in vitro, but have largely non-overlapping functions on common genomic loci such as mitochondrial DNA, telomeric ends, and many replication forks especially at hard-to-replicate regions including ribosomal DNA and G-quadruplex structures. Recently, emerging evidence shows that Pif1, but not Rrm3, has a significant new role in repair-associated DNA synthesis with Polδ during homologous recombination stimulating D-loop migration for conservative DNA replication. Comparative genetic and biochemical studies on the structure and function of Pif1 family helicases across different biological systems are further needed to elucidate both diversity and specificity of their mechanisms of action that contribute to genome stability.

  12. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.

    PubMed

    Müller-Redetzky, Holger C; Felten, Matthias; Hellwig, Katharina; Wienhold, Sandra-Maria; Naujoks, Jan; Opitz, Bastian; Kershaw, Olivia; Gruber, Achim D; Suttorp, Norbert; Witzenrath, Martin

    2015-01-28

    Lung-protective ventilation reduced acute respiratory distress syndrome (ARDS) mortality. To minimize ventilator-induced lung injury (VILI), tidal volume is limited, high plateau pressures are avoided, and positive end-expiratory pressure (PEEP) is applied. However, the impact of specific ventilatory patterns on VILI is not well defined. Increasing inspiratory time and thereby the inspiratory/expiratory ratio (I:E ratio) may improve oxygenation, but may also be harmful as the absolute stress and strain over time increase. We thus hypothesized that increasing inspiratory time and I:E ratio aggravates VILI. VILI was induced in mice by high tidal-volume ventilation (HVT 34 ml/kg). Low tidal-volume ventilation (LVT 9 ml/kg) was used in control groups. PEEP was set to 2 cm H2O, FiO2 was 0.5 in all groups. HVT and LVT mice were ventilated with either I:E of 1:2 (LVT 1:2, HVT 1:2) or 1:1 (LVT 1:1, HVT 1:1) for 4 hours or until an alternative end point, defined as mean arterial blood pressure below 40 mm Hg. Dynamic hyperinflation due to the increased I:E ratio was excluded in a separate group of animals. Survival, lung compliance, oxygenation, pulmonary permeability, markers of pulmonary and systemic inflammation (leukocyte differentiation in lung and blood, analyses of pulmonary interleukin-6, interleukin-1β, keratinocyte-derived chemokine, monocyte chemoattractant protein-1), and histopathologic pulmonary changes were analyzed. LVT 1:2 or LVT 1:1 did not result in VILI, and all individuals survived the ventilation period. HVT 1:2 decreased lung compliance, increased pulmonary neutrophils and cytokine expression, and evoked marked histologic signs of lung injury. All animals survived. HVT 1:1 caused further significant worsening of oxygenation, compliance and increased pulmonary proinflammatory cytokine expression, and pulmonary and blood neutrophils. In the HVT 1:1 group, significant mortality during mechanical ventilation was observed. According to the "baby lung

  13. Adjusting tidal volume to stress index in an open lung condition optimizes ventilation and prevents overdistension in an experimental model of lung injury and reduced chest wall compliance.

    PubMed

    Ferrando, Carlos; Suárez-Sipmann, Fernando; Gutierrez, Andrea; Tusman, Gerardo; Carbonell, Jose; García, Marisa; Piqueras, Laura; Compañ, Desamparados; Flores, Susanie; Soro, Marina; Llombart, Alicia; Belda, Francisco Javier

    2015-01-13

    The stress index (SI), a parameter derived from the shape of the pressure-time curve, can identify injurious mechanical ventilation. We tested the hypothesis that adjusting tidal volume (VT) to a non-injurious SI in an open lung condition avoids hypoventilation while preventing overdistension in an experimental model of combined lung injury and low chest-wall compliance (Ccw). Lung injury was induced by repeated lung lavages using warm saline solution, and Ccw was reduced by controlled intra-abdominal air-insufflation in 22 anesthetized, paralyzed and mechanically ventilated pigs. After injury animals were recruited and submitted to a positive end-expiratory pressure (PEEP) titration trial to find the PEEP level resulting in maximum compliance. During a subsequent four hours of mechanical ventilation, VT was adjusted to keep a plateau pressure (Pplat) of 30 cmH2O (Pplat-group, n = 11) or to a SI between 0.95 and 1.05 (SI-group, n = 11). Respiratory rate was adjusted to maintain a 'normal' PaCO2 (35 to 65 mmHg). SI, lung mechanics, arterial-blood gases haemodynamics pro-inflammatory cytokines and histopathology were analyzed. In addition Computed Tomography (CT) data were acquired at end expiration and end inspiration in six animals. PaCO2 was significantly higher in the Pplat-group (82 versus 53 mmHg, P = 0.01), with a resulting lower pH (7.19 versus 7.34, P = 0.01). We observed significant differences in VT (7.3 versus 5.4 mlKg(-1), P = 0.002) and Pplat values (30 versus 35 cmH2O, P = 0.001) between the Pplat-group and SI-group respectively. SI (1.03 versus 0.99, P = 0.42) and end-inspiratory transpulmonary pressure (PTP) (17 versus 18 cmH2O, P = 0.42) were similar in the Pplat- and SI-groups respectively, without differences in overinflated lung areas at end- inspiration in both groups. Cytokines and histopathology showed no differences. Setting tidal volume to a non-injurious stress index in an open lung condition improves

  14. Perfluorocarbon-associated gas exchange in normal and acid-injured large sheep.

    PubMed

    Hernan, L J; Fuhrman, B P; Kaiser, R E; Penfil, S; Foley, C; Papo, M C; Leach, C L

    1996-03-01

    We hypothesized that a) perfluorocarbon-associated gas exchange could be accomplished in normal large sheep; b) the determinants of gas exchange would be similar during perfluorocarbon-associated gas exchange and conventional gas ventilation; c)in large animals with lung injury, perfluorocarbon-associated gas exchange could be used to enhance gas exchange without adverse effects on hemodynamics; and d) the large animal with lung injury could be supported with an FIO2 of <1.0 during perfluorocarbon-associated gas exchange. Prospective, observational animal study and prospective randomized, controlled animal study. An animal laboratory in a university setting. Thirty adult ewes. Five normal ewes (61.0 +/- 4.0 kg) underwent perfluorocarbon-associated gas exchange to ascertain the effects of tidal volume, end-inspiratory pressure, and positive end-expiratory pressure (PEEP) on oxygenation. Respiratory rate, tidal volume, and minute ventilation were studied to determine their effects on CO2 clearance. Sheep, weighing 58.9 +/- 8.3 kg, had lung injury induced by instilling 2 mL/kg of 0.05 Normal hydrochloric acid into the trachea. Five minutes after injury, PEEP was increased to 10 cm H2O. Ten minutes after injury, sheep with Pao2 values of <100 torr (<13.3 kPa) were randomized to continue gas ventilation (control, n=9) or to institute perfluorocarbon-associated gas exchange (n=9) by instilling 1.6 L of unoxygenated perflubron into the trachea and resuming gas ventilation. Blood gas and hemodynamic measurements were obtained throughout the 4-hr study. Both tidal volume and end-inspiratory pressure influenced oxygenation in normal sheep during perfluorocarbon-associated gas exchange. Minute ventilation determined CO2 clearance during perfluorocarbon-associated gas exchange in normal sheep. After acid aspiration lung injury, perfluorocarbon-associated gas exchange increased PaO2 and reduced intrapulmonary shunt fraction. Hypoxia and intrapulmonary shunting were unabated

  15. The clinical practice guideline for the management of ARDS in Japan.

    PubMed

    Hashimoto, Satoru; Sanui, Masamitsu; Egi, Moritoki; Ohshimo, Shinichiro; Shiotsuka, Junji; Seo, Ryutaro; Tanaka, Ryoma; Tanaka, Yu; Norisue, Yasuhiro; Hayashi, Yoshiro; Nango, Eishu

    2017-01-01

    The Japanese Society of Respiratory Care Medicine and the Japanese Society of Intensive Care Medicine provide here a clinical practice guideline for the management of adult patients with ARDS in the ICU. The guideline was developed applying the GRADE system for performing robust systematic reviews with plausible recommendations. The guideline consists of 13 clinical questions mainly regarding ventilator settings and drug therapies (the last question includes 11 medications that are not approved for clinical use in Japan). The recommendations for adult patients with ARDS include: we suggest against early tracheostomy (GRADE 2C), we suggest using NPPV for early respiratory management (GRADE 2C), we recommend the use of low tidal volumes at 6-8 mL/kg (GRADE 1B), we suggest setting the plateau pressure at 30cmH 2 0 or less (GRADE2B), we suggest using PEEP within the range of plateau pressures less than or equal to 30cmH 2 O, without compromising hemodynamics (Grade 2B), and using higher PEEP levels in patients with moderate to severe ARDS (Grade 2B), we suggest using protocolized methods for liberation from mechanical ventilation (Grade 2D), we suggest prone positioning especially in patients with moderate to severe respiratory dysfunction (GRADE 2C), we suggest against the use of high frequency oscillation (GRADE 2C), we suggest the use of neuromuscular blocking agents in patients requiring mechanical ventilation under certain circumstances (GRADE 2B), we suggest fluid restriction in the management of ARDS (GRADE 2A), we do not suggest the use of neutrophil elastase inhibitors (GRADE 2D), we suggest the administration of steroids, equivalent to methylprednisolone 1-2mg/kg/ day (GRADE 2A), and we do not recommend other medications for the treatment of adult patients with ARDS (GRADE1B; inhaled/intravenous β2 stimulants, prostaglandin E 1 , activated protein C, ketoconazole, and lisofylline, GRADE 1C; inhaled nitric oxide, GRADE 1D; surfactant, GRADE 2B; granulocyte

  16. [Effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection].

    PubMed

    Fan, Yuan-hua; Liu, Yuan-fei; Zhu, Hua-yong; Zhang, Min

    2012-02-01

    To evaluate effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection, based on the protective pulmonary ventilation strategy. Ninety-seven cases with severe pulmonary infection admitted to intensive care unit (ICU) of Ganzhou City People's Hospital undergoing mechanical ventilation were involved. Volume controlled ventilation mode with small tidal volume (8 ml/kg) and positive end-expiratory pressure (PEEP) of 6 cm H(2)O [1 cm H(2)O = 0.098 kPa] was conducted. Each patient underwent recruitment maneuver in supine position and then in prone position [PEEP 20 cm H(2)O+pressure control (PC) 20 cm H(2)O]. Heart rate (HR), mean arterial pressure (MAP), pulse oxygen saturation [SpO(2)] and blood gas analysis data were recorded before and after recruitment maneuver in either position. A double-lumen venous catheter was inserted into internal jugular vein or subclavian vein, and a pulse index contour cardiac output (PiCCO) catheter was introduced into femoral artery. Cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI), intra-thoracic blood volume index (ITBVI), extra vascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), global ejection fraction (GEF), stroke volume variation (SVV) and central vein pressure (CVP) were monitored. (1) Compared with data before recruitment maneuver, there were no significant differences in HR and MAP after supine position and prone position recruitment maneuver, but significant differences in SpO(2) were found between before and after recruitment maneuver when patients' position was changed (supine position: 0.954 ± 0.032 vs. 0.917 ± 0.025, P < 0.05; prone position: 0.982 ± 0.028 vs. 0.936 ± 0.039, P < 0.05). SpO(2) was higher in prone position recruitment maneuver (P < 0.05). (2) Compared with data before recruitment maneuver, CI [L×min(-1)×m(-2)], SVI (ml/m(2)), GEDVI (ml/m(2)) and GEF were decreased significantly during

  17. [EzPAP® therapy of postoperative hypoxemia in the recovery room : experiences with the new compact system of end-expiratory positive airway pressure].

    PubMed

    Rieg, A D; Stoppe, C; Rossaint, R; Coburn, M; Hein, M; Schälte, G

    2012-10-01

    Postoperative hypoxemia is a common complication in the anesthesia recovery room (ARR), which is predominantly based on the development of atelectasis, excessive intraoperative fluid shift and insufficient ventilation. The goal of this prospective observational study was to compare the effect of standard oxygen administration via a face mask with oxygen administration using the EzPAP® system, a device which additionally provides a positive end-expiratory pressure (PEEP). This study included 210 patients with postoperative hypoxemia (S(p)O(2) < 93%) subdivided into the control group (105 patients) and the EzPAP group (105 patients). Postoperative residual paralysis was excluded using relaxometry and a train of four (TOF) ratio of 0.9 was assumed to ensure sufficient recovery of respiratory function from neuromuscular blockade. Patients who received a reversal of neuromuscular blockade were excluded. In cases of hypoxemia (S(p)O(2) < 93%) control patients were treated with oxygen (6 l/min) using a face mask, whereas the EzPAP group received oxygen using the EzPAP® system. In order to adjust the PEEP in the EzPAP group, the O(2) flow was verified and measured by a manometer. After 1 h of oxygen therapy, the oxygen supply was stopped. In cases of reoccurring hypoxemia (S(p)O(2) < 93%, persistence > 5 min), the oxygen therapy was restarted in both groups via a facemask. Both groups were compared using repeat measurement analysis of variance (ANOVA), the unpaired t-test, the Mann-Whitney U-test, Fisher's exact test and the χ(2)-test. The correlation of O(2) flow and PEEP was evaluated by regression analysis and p < 0.05 was considered to be statistically significant. Apart from this a subgroup analysis was performed depending on body-mass index (BMI), American Society of Anesthesiologists (ASA) classification, intraoperative airway management, the use of neuromuscular blocking agents and co-existing disorders, e.g. chronic obstructive lung disease (COLD

  18. Peeping into Human Renal Calcium Oxalate Stone Matrix: Characterization of Novel Proteins Involved in the Intricate Mechanism of Urolithiasis

    PubMed Central

    Tandon, Chanderdeep

    2013-01-01

    Background The increasing number of patients suffering from urolithiasis represents one of the major challenges which nephrologists face worldwide today. For enhancing therapeutic outcomes of this disease, the pathogenic basis for the formation of renal stones is the need of hour. Proteins are found as major component in human renal stone matrix and are considered to have a potential role in crystal–membrane interaction, crystal growth and stone formation but their role in urolithiasis still remains obscure. Methods Proteins were isolated from the matrix of human CaOx containing kidney stones. Proteins having MW>3 kDa were subjected to anion exchange chromatography followed by molecular-sieve chromatography. The effect of these purified proteins was tested against CaOx nucleation and growth and on oxalate injured Madin–Darby Canine Kidney (MDCK) renal epithelial cells for their activity. Proteins were identified by Matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF MS) followed by database search with MASCOT server. In silico molecular interaction studies with CaOx crystals were also investigated. Results Five proteins were identified from the matrix of calcium oxalate kidney stones by MALDI-TOF MS followed by database search with MASCOT server with the competence to control the stone formation process. Out of which two proteins were promoters, two were inhibitors and one protein had a dual activity of both inhibition and promotion towards CaOx nucleation and growth. Further molecular modelling calculations revealed the mode of interaction of these proteins with CaOx at the molecular level. Conclusions We identified and characterized Ethanolamine-phosphate cytidylyltransferase, Ras GTPase-activating-like protein, UDP-glucose:glycoprotein glucosyltransferase 2, RIMS-binding protein 3A, Macrophage-capping protein as novel proteins from the matrix of human calcium oxalate stone which play a critical role in kidney stone formation. Thus, these proteins having potential to modulate calcium oxalate crystallization will throw light on understanding and controlling urolithiasis in humans. PMID:23894559

  19. The Application of High-Resolution Electron Microscopy to Problems in Solid State Chemistry: The Exploits of a Peeping TEM.

    ERIC Educational Resources Information Center

    Eyring, LeRoy

    1980-01-01

    Describes methods for using the high-resolution electron microscope in conjunction with other tools to reveal the identity and environment of atoms. Problems discussed include the ultimate structure of real crystalline solids including defect structure and the mechanisms of chemical reactions. (CS)

  20. Giving peeps to my props: Using 3D printing to shed new light on particle transport in fractured rock.

    NASA Astrophysics Data System (ADS)

    Walsh, S. D.; Du Frane, W. L.; Vericella, J. J.; Aines, R. D.

    2014-12-01

    Smart tracers and smart proppants promise new methods for sensing and manipulating rock fractures. However, the correct use and interpretation of these technologies relies on accurate models of their transport. Even for less exotic particles, the factors controlling particle transport through fractures are poorly understood. In this presentation, we will describe ongoing research at Lawrence Livermore National Laboratory into the transport properties of particles in natural rock fractures. Using three dimensional printing techniques, we create clear-plastic reproductions of real-world fracture surfaces, thereby enabling direct observation of the particle movement. We will also discuss how particle tracking of dense particle packs can be further enhanced by using such specially tailored flow cells in combination with micro-encapsulated tracer particles. Experimental results investigating the transport behavior of smart tracers and proppants close to the neutrally buoyant limit will be presented and we will describe how data from these experiments can be used to improve large-scale models of particle transport in fractures. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  1. Use of helium-oxygen mixture in adult patients presenting with exacerbations of asthma and chronic obstructive pulmonary disease: a systematic review.

    PubMed

    Colebourn, C L; Barber, V; Young, J D

    2007-01-01

    We examined systematically all controlled and cross-over randomised trials in patients with acute exacerbations of asthma and chronic obstructive pulmonary disease comparing Heliox against air-oxygen mixtures. Fourteen studies were identified. In asthma studies, peak expiratory flow rate (PEFR) was increased by an average of 29.6% (95% CI 16.6-42.6) by Heliox-driven nebulisers, or by 13.3 l.min(-1) (95% CI 3.71-22.81) absolute. In studies of patients with chronic obstructive pulmonary disease receiving non-invasive ventilation the arterial carbon dioxide tension (P(a)co(2)) and respiratory rate were unchanged: weighted mean difference for P(a)co(2)-0.29kPa (95% CI - 0.64-0.07) favoured Heliox, and for respiratory rate 1.6 breaths.min(-1) (95% CI - 0.93, 4.14) favoured control. Heliox minimally reduced the work of breathing in intubated patients, and reduced intrinsic positive end expiratory pressure (iPEEP). The use of Heliox to drive nebulisers in patients with acute asthma slightly improves airflow measures. We were unable to determine whether this improved recovery.

  2. Ventilation and gas exchange management after cardiac arrest.

    PubMed

    Sutherasan, Yuda; Raimondo, Pasquale; Pelosi, Paolo

    2015-12-01

    For several decades, physicians had integrated several interventions aiming to improve the outcomes in post-cardiac arrest patients. However, the mortality rate after cardiac arrest is still as high as 50%. Post-cardiac arrest syndrome is associated with high morbidity and mortality due to not only poor neurological outcome and cardiovascular failure but also respiratory dysfunction. To minimize ventilator-associated lung injury, protective mechanical ventilation by using low tidal volume ventilation and driving pressure may decrease pulmonary complications and improve survival. Low level of positive end-expiratory pressure (PEEP) can be initiated and titrated with careful cardiac output and respiratory mechanics monitoring. Furthermore, optimizing gas exchange by avoiding hypoxia and hyperoxia as well as maintaining normocarbia may improve neurological and survival outcome. Early multidisciplinary cardiac rehabilitation intervention is recommended. Minimally invasive monitoring techniques, that is, echocardiography, transpulmonary thermodilution method measuring extravascular lung water, as well as transcranial Doppler ultrasound, might be useful to improve appropriate management of post-cardiac arrest patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. [High-Flow Nasal Cannulae (HFNC) in Neonates: A Survey of Current Practice in Level 1 Perinatal Centres in the German State of North Rhine-Westphalia].

    PubMed

    Hepping, N; Garbe, W; Schneider, K

    2015-12-01

    High-flow nasal cannulae (HFNC) is a kind of non-invasive respiratory support. In recent years, its application has gained increasing popularity for treating neonates with respiratory failure. Within this study, neonatologists employed at high level perinatal centres within the region of North Rhine-Westphalia, Germany were interviewed. We evaluated their personal experience as well as the underlying indication for using HFNC. We undertook an online survey. 93% of the interviewed participants use HFNC systems in their NICU. The most prominent indications were CPAP-weaning, nasal trauma, and apnoea of prematurity. Both initial flow and maximum and minimum flow rates varied widely. The primary benefit of HFNC vs. conventional CPAP was the improved neonate tolerance, less nasal traumata and ease of application and care. A common disadvantage was the inability to conduct PEEP measurements. The application of the HFNC system is increasing for specific neonatal indications, thereby increasing the data for the evaluation of effectivity and safety. Nevertheless, detailed investigations of the appropriate flow rate settings are still lacking. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Definition and epidemiology of acute respiratory distress syndrome

    PubMed Central

    Rezoagli, Emanuele; Fumagalli, Roberto

    2017-01-01

    Fifty years ago, Ashbaugh and colleagues defined for the first time the acute respiratory distress syndrome (ARDS), one among the most challenging clinical condition of the critical care medicine. The scientific community worked over the years to generate a unified definition of ARDS, which saw its revisited version in the Berlin definition, in 2014. Epidemiologic information about ARDS is limited in the era of the new Berlin definition, and wide differences are reported among countries all over the world. Despite decades of study in the field of lung injury, ARDS is still so far under-recognized, with 2 out of 5 cases missed by clinicians. Furthermore, although advances of ventilator strategies in the management of ARDS associated with outcome improvements—such as protective mechanical ventilation, lower driving pressure, higher PEEP levels and prone positioning—ARDS appears to be undertreated and mortality remains elevated up to 40%. In this review, we cover the history that led to the current worldwide accepted Berlin definition of ARDS and we summarize the recent data regarding ARDS epidemiology. PMID:28828357

  5. Low-Tidal-Volume Ventilation in the Acute Respiratory Distress Syndrome

    PubMed Central

    Malhotra, Atul

    2008-01-01

    A 55-year-old man who is 178 cm tall and weighs 95 kg is hospitalized with community-acquired pneumonia and progressively severe dyspnea. His arterial oxygen saturation while breathing 100% oxygen through a face mask is 76%; a chest radiograph shows diffuse alveolar infiltrates with air bronchograms. He is intubated and receives mechanical ventilation; ventilator settings include a tidal volume of 1000 ml, a positive end-expiratory pressure (PEEP) of 5 cm of water, and a fraction of inspired oxygen (FiO2) of 0.8. With these settings, peak airway pressure is 50 to 60 cm of water, plateau airway pressure is 38 cm of water, partial pressure of arterial oxygen is 120 mm Hg, partial pressure of carbon dioxide is 37 mm Hg, and arterial blood pH is 7.47. The diagnosis of the acute respiratory distress syndrome (ARDS) is made. An intensive care specialist evaluates the patient and recommends changing the current ventilator settings and implementing a low-tidal-volume ventilation strategy. PMID:17855672

  6. Time to adjust to changes in ventilation settings varies significantly between different T-piece resuscitators, self-inflating bags, and manometer equipped self-inflating bags.

    PubMed

    Hartung, Julia C; Dold, Simone K; Thio, Marta; tePas, Arjan; Schmalisch, Gerd; Roehr, Charles Christoph

    2014-06-01

    Resuscitation guidelines give no preference over use of self-inflating bags (SIBs) or T-piece resuscitators (TPR) for manual neonatal ventilation. We speculated that devices would differ significantly regarding time required to adjust to changed ventilation settings. This was a laboratory study. Time to adjust from baseline peak inflation pressure (PIP) (20 cmH2O) to target PIP (25 and 40 cmH2O), ability to adhere to predefined ventilation settings (PIP, PEEP, and inflation rate [IR]), and the variability within and between operators were assessed for a SIB without manometer, SIB with manometer (SIBM), and two TPRs. Adjustment time was significantly longer with TPRs, compared with SIB and SIBM. The SIBM and TPRs were < 5% (median) off target PIP, and the SIB was 14% off target PIP. Significant variability between operators (interquartile range [IQR]: 71%) was seen with SIBs. PIP adjustment takes longer with TPRs, compared with SIB/SIBM. TPRs and SIBM allow satisfactory adherence to ventilation parameters. SIBs should only be used with manometer attached. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Early application of airway pressure release ventilation may reduce the duration of mechanical ventilation in acute respiratory distress syndrome.

    PubMed

    Zhou, Yongfang; Jin, Xiaodong; Lv, Yinxia; Wang, Peng; Yang, Yunqing; Liang, Guopeng; Wang, Bo; Kang, Yan

    2017-11-01

    Experimental animal models of acute respiratory distress syndrome (ARDS) have shown that the updated airway pressure release ventilation (APRV) methodologies may significantly improve oxygenation, maximize lung recruitment, and attenuate lung injury, without circulatory depression. This led us to hypothesize that early application of APRV in patients with ARDS would allow pulmonary function to recover faster and would reduce the duration of mechanical ventilation as compared with low tidal volume lung protective ventilation (LTV). A total of 138 patients with ARDS who received mechanical ventilation for <48 h between May 2015 to October 2016 while in the critical care medicine unit (ICU) of the West China Hospital of Sichuan University were enrolled in the study. Patients were randomly assigned to receive APRV (n = 71) or LTV (n = 67). The settings for APRV were: high airway pressure (P high ) set at the last plateau airway pressure (P plat ), not to exceed 30 cmH 2 O) and low airway pressure ( P low ) set at 5 cmH 2 O; the release phase (T low ) setting adjusted to terminate the peak expiratory flow rate to ≥ 50%; release frequency of 10-14 cycles/min. The settings for LTV were: target tidal volume of 6 mL/kg of predicted body weight; P plat not exceeding 30 cmH 2 O; positive end-expiratory pressure (PEEP) guided by the PEEP-FiO 2 table according to the ARDSnet protocol. The primary outcome was the number of days without mechanical ventilation from enrollment to day 28. The secondary endpoints included oxygenation, P plat , respiratory system compliance, and patient outcomes. Compared with the LTV group, patients in the APRV group had a higher median number of ventilator-free days {19 [interquartile range (IQR) 8-22] vs. 2 (IQR 0-15); P < 0.001}. This finding was independent of the coexisting differences in chronic disease. The APRV group had a shorter stay in the ICU (P = 0.003). The ICU mortality rate was 19.7% in the APRV group versus 34.3% in the

  8. Ventilation practices in subarachnoid hemorrhage: a cohort study exploring the use of lung protective ventilation.

    PubMed

    Marhong, Jonathan D; Ferguson, Niall D; Singh, Jeffrey M

    2014-10-01

    Acute respiratory distress syndrome (ARDS) is common following aneurysmal subarachnoid hemorrhage (SAH), but the influence of mechanical ventilator settings on its development is unclear. We sought to determine adherence to lung protective thresholds in ventilated patients with SAH and describe the association between ventilator settings and subsequent development of ARDS. We conducted a retrospective cohort study of consecutive patients receiving mechanical ventilation within 72 h of SAH at a single academic center. Ventilator settings and blood gas data were collected twice daily for the first 7 days of ventilation along with ICU and hospital outcomes. Lung protective ventilation was defined as follows: tidal volume ≤8 mL/kg of predicted body weight, positive end-expiratory pressure (PEEP) ≥5 cm H(2)O, and peak or plateau pressure ≤30 cm H(2)O. The development of ARDS was ascertained retrospectively by PaO(2)/FiO(2) ≤300 with new bilateral lung opacities on chest X-ray within one day of hypoxemia. We identified 62 patients who underwent early mechanical ventilation following SAH. PS and Continuous Positive Airway Pressure were common ventilator modes with a median tidal volume of 7.8 mL/kg [interquartile range 6.8-8.8], median peak pressure of 14 cm H(2)O [IQR 12-17], and median PEEP of 5 cm H(2)O [IQR 5-6]. Adherence to tidal volumes ≤8 mL/kg was seen in 64 % of all observations and peak pressures <30 cm H(2)O were 94 % of all observations. All three lung protective criteria were seen in 58 % of all observations. Thirty-one patients (50 %) were determined to have ARDS. ARDS patients were more frequently ventilated with a peak pressure >30 cm H(2)O (11.3 % of ARDS ventilation days vs. 0 % of non-ARDS ventilation days; p < 0.01). Initial tidal volume was not associated with subsequent development of ARDS in univariate (p = 0.6) or multivariate analysis (p = 0.49). Only the number of ARDS risk factors was independently associated with the development of

  9. An attempt to validate the modification of the American-European consensus definition of acute lung injury/acute respiratory distress syndrome by the Berlin definition in a university hospital.

    PubMed

    Hernu, R; Wallet, F; Thiollière, F; Martin, O; Richard, J C; Schmitt, Z; Wallon, G; Delannoy, B; Rimmelé, T; Démaret, C; Magnin, C; Vallin, H; Lepape, A; Baboi, L; Argaud, L; Piriou, V; Allaouchiche, B; Aubrun, F; Bastien, O; Lehot, J J; Ayzac, L; Guérin, C

    2013-12-01

    The Berlin definition for acute respiratory distress syndrome (ARDS) is a new proposal for changing the American-European consensus definition but has not been assessed prospectively as yet. In the present study, we aimed to determine (1) the prevalence and incidence of ARDS with both definitions, and (2) the initial characteristics of patients with ARDS and 28-day mortality with the Berlin definition. We performed a 6-month prospective observational study in the ten adult ICUs affiliated to the Public University Hospital in Lyon, France, from March to September 2012. Patients under invasive or noninvasive mechanical ventilation, with PaO2/FiO2 <300 mmHg regardless of the positive end-expiratory pressure (PEEP) level, and acute onset of new or increased bilateral infiltrates or opacities on chest X-ray were screened from ICU admission up to discharge. Patients with cardiogenic pulmonary edema were excluded. Patients were further classified into specific categories by using the American-European Consensus Conference and the Berlin definition criteria. The complete data set was measured at the time of inclusion. Patient outcome was measured at day 28 after inclusion. During the study period 3,504 patients were admitted and 278 fulfilled the American-European Consensus Conference criteria. Among them, 18 (6.5 %) did not comply with the Berlin criterion PEEP ≥ 5 cmH2O and 20 (7.2 %) had PaO2/FiO2 ratio ≤200 while on noninvasive ventilation. By using the Berlin definition in the remaining 240 patients (n = 42 mild, n = 123 moderate, n = 75 severe), the overall prevalence was 6.85 % and it was 1.20, 3.51, and 2.14 % for mild, moderate, and severe ARDS, respectively (P > 0.05 between the three groups). The incidence of ARDS amounted to 32 per 100,000 population per year, with values for mild, moderate, and severe ARDS of 5.6, 16.3, and 10 per 100,000 population per year, respectively (P < 0.05 between the three groups). The 28-day mortality was 35.0 %. It amounted to

  10. A standardized model of brain death, donor treatment, and lung transplantation for studies on organ preservation and reconditioning.

    PubMed

    Valenza, Franco; Coppola, Silvia; Froio, Sara; Ruggeri, Giulia Maria; Fumagalli, Jacopo; Villa, Alessandro Maria; Rosso, Lorenzo; Mendogni, Paolo; Conte, Grazia; Lonati, Caterina; Carlin, Andrea; Leonardi, Patrizia; Gatti, Stefano; Stocchetti, Nino; Gattinoni, Luciano

    2014-12-01

    We set a model of brain death, donor management, and lung transplantation for studies on lung preservation and reconditioning before transplantation. Ten pigs (39.7 ± 5.9 Kg) were investigated. Five animals underwent brain death and were treated as organ donors; the lungs were then procured and cold stored (Ischemia). Five recipients underwent left lung transplantation and post-reperfusion follow-up (Graft). Cardiorespiratory and metabolic parameters were collected. Lung gene expression of cytokines (tumor necrosis factor alpha (TNFα), interleukin-1 beta (IL-1β), interleukin-6 (IL-6), interferon gamma (IFNγ), high mobility group box-1 (HMGB-1)), chemokines (chemokine CC motif ligand-2 (CCL2-MCP-1), chemokine CXC motif ligand-10 (CXCL-10), interleukin-8 (IL-8)), and endothelial activation markers (endothelin-1 (EDN-1), intercellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), selectin-E (SELE)) was assessed by real-time polymerase chain reaction (PCR). Tachycardia and hypertension occurred during brain death induction; cardiac output rose, systemic vascular resistance dropped (P < 0.05), and diabetes insipidus occurred. Lung-protective ventilation strategy was applied: 9 h after brain death induction, PaO2 was 192 ± 12 mmHg at positive end-expiratory pressure (PEEP) 8.0 ± 1.8 cmH2O and FiO2 of 40%; wet-to-dry ratio (W/D) was 5.8 ± 0.5, and extravascular lung water (EVLW) was 359 ± 80 mL. Procured lungs were cold-stored for 471 ± 24 min (Ischemia) at the end of which W/D was 6.1 ± 0.9. Left lungs were transplanted and reperfused (warm ischemia 98 ± 14 min). Six hours after controlled reperfusion, PaO2 was 192 ± 23 mmHg (PEEP 8.7 ± 1.5 cmH2O, FiO2 40%), W/D was 5.6 ± 0.4, and EVLW was 366 ± 117 mL. Levels of IL-8 rose at the end of donor management (BD, P < 0.05); CCL2-MCP-1, IL-8, HMGB-1, and SELE were significantly altered after reperfusion (Graft, P < 0

  11. Effect of driving pressure on mortality in ARDS patients during lung protective mechanical ventilation in two randomized controlled trials.

    PubMed

    Guérin, Claude; Papazian, Laurent; Reignier, Jean; Ayzac, Louis; Loundou, Anderson; Forel, Jean-Marie

    2016-11-29

    Driving pressure (ΔPrs) across the respiratory system is suggested as the strongest predictor of hospital mortality in patients with acute respiratory distress syndrome (ARDS). We wonder whether this result is related to the range of tidal volume (V T ). Therefore, we investigated ΔPrs in two trials in which strict lung-protective mechanical ventilation was applied in ARDS. Our working hypothesis was that ΔPrs is a risk factor for mortality just like compliance (Crs) or plateau pressure (Pplat,rs) of the respiratory system. We performed secondary analysis of data from 787 ARDS patients enrolled in two independent randomized controlled trials evaluating distinct adjunctive techniques while they were ventilated as in the low V T arm of the ARDSnet trial. For this study, we used V T , positive end-expiratory pressure (PEEP), Pplat,rs, Crs, ΔPrs, and respiratory rate recorded 24 hours after randomization, and compared them between survivors and nonsurvivors at day 90. Patients were followed for 90 days after inclusion. Cox proportional hazard modeling was used for mortality at day 90. If colinearity between ΔPrs, Crs, and Pplat,rs was verified, specific Cox models were used for each of them. Both trials enrolled 805 patients of whom 787 had day-1 data available, and 533 of these survived. In the univariate analysis, ΔPrs averaged 13.7 ± 3.7 and 12.8 ± 3.7 cmH 2 O (P = 0.002) in nonsurvivors and survivors, respectively. Colinearity between ΔPrs, Crs and Pplat,rs, which was expected as these variables are mathematically coupled, was statistically significant. Hazard ratios from the Cox models for day-90 mortality were 1.05 (1.02-1.08) (P = 0.005), 1.05 (1.01-1.08) (P = 0.008) and 0.985 (0.972-0.985) (P = 0.029) for ΔPrs, Pplat,rs and Crs, respectively. PEEP and V T were not associated with death in any model. When ventilating patients with low V T , ΔPrs is a risk factor for death in ARDS patients, as is Pplat,rs or Crs. As our data

  12. Effect of lung resection on pleuro-pulmonary mechanics and fluid balance.

    PubMed

    Salito, C; Bovio, D; Orsetti, G; Salati, M; Brunelli, A; Aliverti, A; Miserocchi, G

    2016-01-15

    The aim of the study was to determine in human patients the effect of lung resection on lung compliance and on pleuro-pulmonary fluid balance. Pre and post-operative values of compliance were measured in anesthetized patients undergoing resection for lung cancer (N=11) through double-lumen bronchial intubation. Lung compliance was measured for 10-12 cm H2O increase in alveolar pressure from 5 cm H2O PEEP in control and repeated after resection. No air leak was assessed and pleural fluid was collected during hospital stay. A significant negative correlation (r(2)=0.68) was found between compliance at 10 min and resected mass. Based on the pre-operative estimated lung weight, the decrease in compliance following lung resection exceeded by 10-15% that expected from resected mass. Significant negative relationships were found by relating pleural fluid drainage flow to the remaining lung mass and to post-operative lung compliance. Following lung re-expansion, data suggest a causative relationship between the decrease in compliance and the perturbation in pleuro-pulmonary fluid balance. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Recurrent Spontaneous Pneumothorax during the Recovery Phase of ARDS Due to H1N1 Infection.

    PubMed

    Bor, Canan; Demirağ, Kubilay; Uyar, Mehmet; Cankayalı, Ilkin; Moral, Ali Reşat

    2013-03-01

    The pregnant patients are prone to influenza A (H1N1) virus infection, which may rapidly progress to lower respiratory tract infection and subsequent respiratory failure and acute respiratory distress syndrome (ARDS). Pneumothorax might develop in ARDS under mechanical ventilation. But post-ARDS pneumothorax in spontaneously breathing patient has not been reported in the literature. We report a 31-year old pregnant woman infected with influenza A (H1N1) virus and progressed to ARDS. Mechanical ventilation with high PEEP improved patient's gas exchange parameters within 3 weeks. However spontaneous pneumothorax was developed one week after she weaned off the ventilator. After successful drainage therapy, the patient was discharged. However she re-admitted to the hospital because of a recurrent pneumothorax one week later. She was discharged in good health after being treated with negative continuous pleural aspiration for 10 days. Influenza might cause severe pulmonary infection and death. In addition to diffuse alveolar damage, sub-pleural and intrapulmonary air cysts might occur in influenza-related ARDS and may lead to spontaneous pneumothorax. This complication should always be considered during the recovery period of ARDS and a long-term close follow-up is necessary.

  14. THE CHILD'S SEXUAL LIFE—A Consideration of Clinical Implications

    PubMed Central

    Teicher, Joseph D.

    1957-01-01

    A healthy sexual life begins in childhood, and the groundwork for later difficulties also begins in childhood. For the child, sexuality is a rather general, pleasurable excitation, not a specific genital stimulation. Excessive attention to the perineal area, operation upon or injury to the genital area and injections are vicissitudes which may have an unhealthy influence on later sexual development. Healthy and informed parental attitudes are the key here, just as they are in the normal exhibitionism, curiosity and intense emotional attachments to parents. Parents infect children, healthily or unhealthily, with their attitudes. In healthy growth exhibitionism and peeping become transformed in socially acceptable ways. In unhealthy growth, either perversions or strong reactions like over-modesty or shame result. Masturbation is common and transitory in most children. Parents, and especially pediatricians to whom parents turn, have a golden opportunity to direct healthy growth by being well informed about the infant and child's sexual growth and thus be enabled to advise upon or manage the common developmental phenomena with good commonsense and patience. Infants and children do not enter the world possessing the morals, standards or inhibitions of adults. PMID:13426800

  15. Protective mechanical ventilation, why use it?

    PubMed

    Seiberlich, Emerson; Santana, Jonas Alves; Chaves, Renata de Andrade; Seiberlich, Raquel Carvalho

    2011-01-01

    Mechanical ventilation (MV) strategies have been modified over the last decades with a tendency for increasingly lower tidal volumes (VT). However, in patients without acute lung injury (ALI) or acute respiratory distress syndrome (ARDS) the use of high VTs is still very common. Retrospective studies suggest that this practice can be related to mechanical ventilation-associated ALI. The objective of this review is to search for evidence to guide protective MV in patients with healthy lungs and to suggest strategies to properly ventilate lungs with ALI/ARDS. A review based on the main articles that focus on the use of strategies of mechanical ventilation was performed. Consistent studies to determine which would be the best way to ventilate a patient with healthy lungs are lacking. Expert recommendations and current evidence presented in this article indicate that the use of a VT lower than 10 mL.kg(-1), associated with positive end-expiratory pressure (PEEP) ≥ 5 cmH(2)O without exceeding a pressure plateau of 15 to 20 cmH(2)O could minimize alveolar stretching at the end of inspiration and avoid possible inflammation or alveolar collapse. Copyright © 2011 Elsevier Editora Ltda. All rights reserved.

  16. [Effect of different transpulmonary pressures guided mechanical ventilation on respiratory and hemodynamics of patients with ARDS: a prospective randomized controlled trial].

    PubMed

    Li, Jianqiu; Luo, Zhihui; Li, Xiaolei; Huang, Zhongyi; Han, Jie; Li, Zifeng; Zhou, Zhaoxiong; Chen, Houwang

    2017-01-01

    the baseline was equivalent and comparable. The respiratory function and hemodynamic parameters showed no obvious change in control group at different time points of MV; but with the extension of ventilation, the respiratory function was improved significantly in observation group, and the gradually rising of Ptp had obvious adverse effects on hemodynamics parameters. Compared with control group, at 48 hours of ventilation after setting Ptp, the respiratory function in Ptp 20 cmH 2 O subgroup was improved significantly, PaO 2 /FiO 2 , arterial partial pressure of carbon dioxide (PaCO 2 ), positive end-expiratory pressure (PEEP), airway platform pressure (Pplat), and lung compliance (Cst) were significantly increased [PaO 2 /FiO 2 (mmHg, 1 mmHg = 0.133 kPa): 220.9±30.8 vs. 178.5±42.9, PaCO 2 (mmHg): 55.1±7.6 vs. 38.6±4.8, PEEP (cmH 2 O): 24.7±4.8 vs. 6.6±2.2, Pplat (cmH 2 O): 34.4±3.7 vs. 20.7±3.5, Cst (mL/cmH 2 O): 23.8±3.6 vs. 13.1±4.6; all P < 0.05], and extravascular lung water index (ELWI) was significantly decreased (mL/kg: 6.8±1.7 vs. 10.8±2.6, P < 0.05), but mean artery pressure (MAP), cardiac index (CI), global end-diastolic volume index (GEDVI) such as hemodynamics parameters were also significantly reduced [MAP (mmHg): 58.8±6.7 vs. 69.7±4.7, CI (mL×s -1 ×m -2 ): 46.7±23.3 vs. 73.3±30.0, GEDVI (mL/m 2 ): 633.2±45.2 vs. 702.6±55.7; all P < 0.05]; the PaO 2 /FiO 2 , PEEP, Pplat, and Cst in Ptp 10 cmH 2 O subgroup were significantly increased [PaO 2 /FiO 2 (mmHg): 183.4±45.5 vs. 178.5±42.9, PEEP (cmH 2 O): 14.4±3.6 vs. 6.6±2.2, Pplat (cmH 2 O): 25.7±5.6 vs. 20.7±3.5, Cst (mL/cmH 2 O): 16.2±4.3 vs. 13.1±4.6; all P < 0.05], and ELWI was significantly reduced (mL/kg: 8.7±1.8 vs. 10.8±2.6, P < 0.05), but the MAP, CI and GEDVI showed no significant difference [MAP (mmHg): 65.8±4.6 vs. 69.7±4.7, CI (mL×s -1 ×m -2 ): 65.0±35.0 vs. 73.3±30.0, GEDVI (mL/m 2 ): 706.7±54.4 vs. 702.6±55.7; all P > 0.05]. The above illustrated that 10 cm

  17. Epidemiology, Patterns of Care, and Mortality for Patients With Acute Respiratory Distress Syndrome in Intensive Care Units in 50 Countries.

    PubMed

    Bellani, Giacomo; Laffey, John G; Pham, Tài; Fan, Eddy; Brochard, Laurent; Esteban, Andres; Gattinoni, Luciano; van Haren, Frank; Larsson, Anders; McAuley, Daniel F; Ranieri, Marco; Rubenfeld, Gordon; Thompson, B Taylor; Wrigge, Hermann; Slutsky, Arthur S; Pesenti, Antonio

    2016-02-23

    -expository pressure (PEEP) of less than 12 cm H2O. Prone positioning was used in 16.3% (95% CI, 13.7%-19.2%) of patients with severe ARDS. Clinician recognition of ARDS was associated with higher PEEP, greater use of neuromuscular blockade, and prone positioning. Hospital mortality was 34.9% (95% CI, 31.4%-38.5%) for those with mild, 40.3% (95% CI, 37.4%-43.3%) for those with moderate, and 46.1% (95% CI, 41.9%-50.4%) for those with severe ARDS. Among ICUs in 50 countries, the period prevalence of ARDS was 10.4% of ICU admissions. This syndrome appeared to be underrecognized and undertreated and associated with a high mortality rate. These findings indicate the potential for improvement in the management of patients with ARDS. clinicaltrials.gov Identifier: NCT02010073.

  18. Continued under-recognition of acute respiratory distress syndrome after the Berlin definition: what is the solution?

    PubMed

    Laffey, John G; Pham, Tài; Bellani, Giacomo

    2017-02-01

    Timely recognition of acute respiratory distress syndrome (ARDS) may allow for more prompt management and less exacerbation of lung injury. However, the absence of a diagnostic test for ARDS means that the diagnosis of ARDS requires clinician recognition in what is usually a complicated and evolving illness. We review data concerning the extent of recognition of ARDS in the era of the Berlin definition of ARDS. ARDS continues to be under-recognized - even in the era of the more recent 'Berlin' definition, and significant delay in its recognition is common. Factors contributing to under-recognition may include the complexity of ARDS biology, low specificity of the consensus (diagnostic) criteria, and concerns about reliable interpretation of the chest radiograph. Understandably, 'external' factors are also at play: ICU occupancy and higher patient to clinician ratio impair recognition of ARDS. Timely recognition of ARDS appears important, as it is associated with the use of higher PEEP, prone positioning and neuromuscular blockade which can lower mortality. Computer-aided decision tools seem diagnostically useful, and together with the integration of reliable biomarkers, may further enhance and speed recognition of this syndrome. Significant numbers of patients with ARDS are still unrecognized by clinicians in the era of the Berlin definition of ARDS, with potentially important consequences for patient management and outcome.

  19. Impact of continuous positive airway pressure (CPAP) on the respiratory capacity of chronic kidney disease patients under hemodialysis treatment.

    PubMed

    Xavier, Vivian Bertoni; Roxo, Renata Spósito; Miorin, Luiz Antônio; Dos Santos Alves, Vera Lúcia; Dos Santos Sens, Yvoty Alves

    2015-06-01

    Chronic kidney disease (CKD) patients on long-term dialysis present changes in pulmonary function and respiratory muscle strength, negatively influencing physical capacity. To analyze the impact of a continuous positive airway pressure (CPAP) protocol on the respiratory capacity of CKD patients under hemodialysis. A randomized clinical trial was conducted involving 40 CKD patients 19-83 years old divided into two groups: control (n = 20) and CPAP (n = 20). Subjects were assessed on the respiratory muscle function test, maximal respiratory pressures, peak flow and 6-min walk test, at baseline and again at the 2-month follow-up. CPAP group patients were submitted to CPAP protocol (PEEP: 5 cm H2O, flow: 15 L/min, FiO2: 33 %) three times per week during hemodialysis sessions. The CPAP group showed higher forced vital capacity, forced expiratory volume in one second, peak expiratory flow, maximal inspiratory pressure, peak flow, as well as lower systolic blood pressure, heart rate, respiratory rate and Borg scale, in addition to a longer distance travelled on the 6-min walk test, compared with the control group. The introduction of a CPAP protocol during hemodialysis sessions had a positive impact on pulmonary function and physical capacity in CKD patients.

  20. The vocal repertoire of the African Penguin (Spheniscus demersus): structure and function of calls.

    PubMed

    Favaro, Livio; Ozella, Laura; Pessani, Daniela

    2014-01-01

    The African Penguin (Spheniscus demersus) is a highly social and vocal seabird. However, currently available descriptions of the vocal repertoire of African Penguin are mostly limited to basic descriptions of calls. Here we provide, for the first time, a detailed description of the vocal behaviour of this species by collecting audio and video recordings from a large captive colony. We combine visual examinations of spectrograms with spectral and temporal acoustic analyses to determine vocal categories. Moreover, we used a principal component analysis, followed by signal classification with a discriminant function analysis, for statistical validation of the vocalisation types. In addition, we identified the behavioural contexts in which calls were uttered. The results show that four basic vocalisations can be found in the vocal repertoire of adult African Penguin, namely a contact call emitted by isolated birds, an agonistic call used in aggressive interactions, an ecstatic display song uttered by single birds, and a mutual display song vocalised by pairs, at their nests. Moreover, we identified two distinct vocalisations interpreted as begging calls by nesting chicks (begging peep) and unweaned juveniles (begging moan). Finally, we discussed the importance of specific acoustic parameters in classifying calls and the possible use of the source-filter theory of vocal production to study penguin vocalisations.

  1. An object-oriented computational model to study cardiopulmonary hemodynamic interactions in humans.

    PubMed

    Ngo, Chuong; Dahlmanns, Stephan; Vollmer, Thomas; Misgeld, Berno; Leonhardt, Steffen

    2018-06-01

    This work introduces an object-oriented computational model to study cardiopulmonary interactions in humans. Modeling was performed in object-oriented programing language Matlab Simscape, where model components are connected with each other through physical connections. Constitutive and phenomenological equations of model elements are implemented based on their non-linear pressure-volume or pressure-flow relationship. The model includes more than 30 physiological compartments, which belong either to the cardiovascular or respiratory system. The model considers non-linear behaviors of veins, pulmonary capillaries, collapsible airways, alveoli, and the chest wall. Model parameters were derisved based on literature values. Model validation was performed by comparing simulation results with clinical and animal data reported in literature. The model is able to provide quantitative values of alveolar, pleural, interstitial, aortic and ventricular pressures, as well as heart and lung volumes during spontaneous breathing and mechanical ventilation. Results of baseline simulation demonstrate the consistency of the assigned parameters. Simulation results during mechanical ventilation with PEEP trials can be directly compared with animal and clinical data given in literature. Object-oriented programming languages can be used to model interconnected systems including model non-linearities. The model provides a useful tool to investigate cardiopulmonary activity during spontaneous breathing and mechanical ventilation. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Examining gender based violence and abuse among Liberian school students in four counties: An exploratory study.

    PubMed

    Postmus, Judy L; Hoge, Gretchen L; Davis, Rebecca; Johnson, Laura; Koechlein, Elizabeth; Winter, Samantha

    2015-06-01

    The purpose of this article is to uncover the extent of sexual gender based violence (GBV) experienced by a convenience sample of students from select counties in Liberia and to understand the disclosure experiences of those victims willing to come forward. Girls (n=758) and boys (n=1,100) were asked about their sexual GBV experiences including their disclosure experiences, if applicable. Results indicated that sexual violation (i.e., peeping or inappropriate touching) was found among both girls and boys. Sexual coercion (i.e., forced sex) was more prevalent than transactional sex (i.e., trading sex for grades or money). Both sexual coercion and transactional sex were reported by more girls than boys, yet the rates for the most severe form of sexual violence (i.e., sexual coercion) were high for both girls (30%) and boys (22%). When students were asked if they told anyone, 38% reported that they did disclose their experiences. This study contributes to a small but growing body of research to document the prevalence and types of sexual violence against children in Liberia. Consistent with other studies, the evidence shows that sexual violence against boys and girls is occurring at alarming rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    PubMed

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  4. Cerebral processing of auditory stimuli in patients with irritable bowel syndrome

    PubMed Central

    Andresen, Viola; Poellinger, Alexander; Tsrouya, Chedwa; Bach, Dominik; Stroh, Albrecht; Foerschler, Annette; Georgiewa, Petra; Schmidtmann, Marco; van der Voort, Ivo R; Kobelt, Peter; Zimmer, Claus; Wiedenmann, Bertram; Klapp, Burghard F; Monnikes, Hubert

    2006-01-01

    AIM: To determine by brain functional magnetic resonance imaging (fMRI) whether cerebral processing of non-visceral stimuli is altered in irritable bowel syndrome (IBS) patients compared with healthy subjects. To circumvent spinal viscerosomatic convergence mechanisms, we used auditory stimulation, and to identify a possible influence of psychological factors the stimuli differed in their emotional quality. METHODS: In 8 IBS patients and 8 controls, fMRI measurements were performed using a block design of 4 auditory stimuli of different emotional quality (pleasant sounds of chimes, unpleasant peep (2000 Hz), neutral words, and emotional words). A gradient echo T2*-weighted sequence was used for the functional scans. Statistical maps were constructed using the general linear model. RESULTS: To emotional auditory stimuli, IBS patients relative to controls responded with stronger deactivations in a greater variety of emotional processing regions, while the response patterns, unlike in controls, did not differentiate between distressing or pleasant sounds. To neutral auditory stimuli, by contrast, only IBS patients responded with large significant activations. CONCLUSION: Altered cerebral response patterns to auditory stimuli in emotional stimulus-processing regions suggest that altered sensory processing in IBS may not be specific for visceral sensation, but might reflect generalized changes in emotional sensitivity and affective reactivity, possibly associated with the psychological comorbidity often found in IBS patients. PMID:16586541

  5. KSC-2011-8246

    NASA Image and Video Library

    2011-12-11

    CAPE CANAVERAL, Fla. – The high-fidelity space shuttle model that was on display at the NASA Kennedy Space Center Visitor Complex in Florida negotiates the turn from Kennedy Parkway onto Schwartz Road on its way toward NASA Kennedy Space Center's Launch Complex 39 turn basin. It is standard procedure for large payloads and equipment to travel against the normal flow of traffic under the supervision of a move crew when being transported on or off center property. The 525-foot-tall Vehicle Assembly Building peeps over the treetops, at right. The shuttle was part of a display at the visitor complex that also included an external tank and two solid rocket boosters that were used to show visitors the size of actual space shuttle components. The full-scale shuttle model is being transferred from Kennedy to Space Center Houston, NASA Johnson Space Center's visitor center. The model will stay at the turn basin for a few months until it is ready to be transported to Texas via barge. The move also helps clear the way for the Kennedy Space Center Visitor Complex to begin construction of a new facility next year to display space shuttle Atlantis in 2013. For more information about Space Center Houston, visit http://www.spacecenter.org. Photo credit: NASA/Dimitri Gerondidakis

  6. ARDS: challenges in patient care and frontiers in research.

    PubMed

    Bos, Lieuwe D; Martin-Loeches, Ignacio; Schultz, Marcus J

    2018-03-31

    This review discusses the clinical challenges associated with ventilatory support and pharmacological interventions in patients with acute respiratory distress syndrome (ARDS). In addition, it discusses current scientific challenges facing researchers when planning and performing trials of ventilatory support or pharmacological interventions in these patients.Noninvasive mechanical ventilation is used in some patients with ARDS. When intubated and mechanically ventilated, ARDS patients should be ventilated with low tidal volumes. A plateau pressure <30 cmH 2 O is recommended in all patients. It is suggested that a plateau pressure <15 cmH 2 O should be considered safe. Patient with moderate and severe ARDS should receive higher levels of positive end-expiratory pressure (PEEP). Rescue therapies include prone position and neuromuscular blocking agents. Extracorporeal support for decapneisation and oxygenation should only be considered when lung-protective ventilation is no longer possible, or in cases of refractory hypoxaemia, respectively. Tracheotomy is only recommended when prolonged mechanical ventilation is expected.Of all tested pharmacological interventions for ARDS, only treatment with steroids is considered to have benefit.Proper identification of phenotypes, known to respond differently to specific interventions, is increasingly considered important for clinical trials of interventions for ARDS. Such phenotypes could be defined based on clinical parameters, such as the arterial oxygen tension/inspiratory oxygen fraction ratio, but biological marker profiles could be more promising. Copyright ©ERS 2018.

  7. Statistical analysis plan for the Alveolar Recruitment for Acute Respiratory Distress Syndrome Trial (ART). A randomized controlled trial

    PubMed Central

    Damiani, Lucas Petri; Berwanger, Otavio; Paisani, Denise; Laranjeira, Ligia Nasi; Suzumura, Erica Aranha; Amato, Marcelo Britto Passos; Carvalho, Carlos Roberto Ribeiro; Cavalcanti, Alexandre Biasi

    2017-01-01

    Background The Alveolar Recruitment for Acute Respiratory Distress Syndrome Trial (ART) is an international multicenter randomized pragmatic controlled trial with allocation concealment involving 120 intensive care units in Brazil, Argentina, Colombia, Italy, Poland, Portugal, Malaysia, Spain, and Uruguay. The primary objective of ART is to determine whether maximum stepwise alveolar recruitment associated with PEEP titration, adjusted according to the static compliance of the respiratory system (ART strategy), is able to increase 28-day survival in patients with acute respiratory distress syndrome compared to conventional treatment (ARDSNet strategy). Objective To describe the data management process and statistical analysis plan. Methods The statistical analysis plan was designed by the trial executive committee and reviewed and approved by the trial steering committee. We provide an overview of the trial design with a special focus on describing the primary (28-day survival) and secondary outcomes. We describe our data management process, data monitoring committee, interim analyses, and sample size calculation. We describe our planned statistical analyses for primary and secondary outcomes as well as pre-specified subgroup analyses. We also provide details for presenting results, including mock tables for baseline characteristics, adherence to the protocol and effect on clinical outcomes. Conclusion According to best trial practice, we report our statistical analysis plan and data management plan prior to locking the database and beginning analyses. We anticipate that this document will prevent analysis bias and enhance the utility of the reported results. Trial registration ClinicalTrials.gov number, NCT01374022. PMID:28977255

  8. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    PubMed

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (p<0.001) and compliance and lower ESV, EDV and airway pressures (p<0.05) than during the use of VCV. Oxygenation indices were similar during the use of VCV and PCV. The use of PCV offers more improved RV function than the use of VCV during OLV for open thoracotomy. These results apply specifically to younger patients with good ventricular and pulmonary functions. © 2014 Elsevier Inc. All rights reserved.

  9. Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALI.

    PubMed

    Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik

    2013-06-01

    The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.

  10. Effects of monochromatic light stimuli during embryogenesis on some performance traits, behavior, and fear responses in Japanese quails.

    PubMed

    Sabuncuoglu, Kübra Melis; Korkmaz, Firdevs; Gürcan, Eser Kemal; Narinç, Dogan; Saml X, Hasan Ersin

    2018-04-14

    Lighting is crucial in poultry rearing and the subjects with light intensity, source, and color having been addressed in numerous studies. Numerous studies with monochromatic light from light-emitting diode (LED) bulbs have been reported. In the current study, fertile Japanese quail eggs were exposed to a dark environment (Control) or monochromatic green (560 nm) and blue (480 nm) lighting throughout incubation. There were no significant differences in hatch weight, hatchability, total embryonic mortality, hatch time, growth performance, and slaughter-carcass traits in the study (P > 0.05). Furthermore, the lowest mean in terms of early embryonic mortalities (12.37%) was determined in the group treated with green LED lighting (P < 0.05), whereas it was discovered that the lowest mean in terms of late embryonic mortalities (13.59%) was in the group treated with blue LED lighting (P < 0.05). During the test time, the green LED group showed higher averages in terms of the number of peeps and first defecation time as response to environmental stimuli (P < 0.05). The highest mean for jumping (7.6 times) was detected in the group treated with blue LED lighting (P < 0.05). In conclusion, it was revealed that the blue and green LED lighting applied to the Japanese quail eggs in incubation had no effects on incubation traits, growth, and slaughter-carcass traits but had positive effects on some behavioral traits.

  11. Lessons to learn from epidemiologic studies in ARDS.

    PubMed

    McNicholas, Bairbre A; Rooney, Grainne M; Laffey, John G

    2018-02-01

    Recent advances in our understanding of the epidemiology of ARDS has generated key insights into the incidence, risk factors, demographics, management and outcomes from this devastating clinical syndrome. ARDS occurs in 10% of all ICU patients, in 23% of all mechanically ventilated patients, with 5.5 cases per ICU bed each year. Although some regional variation exists regarding ARDS incidence, this may be less than previously thought. Subphenotypes are increasingly identified within the ARDS cohort, with studies identifying a 'hyperinflammatory' or 'reactive' subgroup that has a higher mortality, and may respond differently to therapeutic interventions. Demographic factors, such as race, may also affect the therapeutic response. Although mortality in ARDS is decreasing in clinical trials, it remains unchanged at approximately 40% in major observational studies. Modifiable ventilatory management factors, including PEEP, airway pressures, and respiratory rate are associated with mortality in ARDS. Hospital and ICU organizational factors play a role in outcome, whereas socioeconomic status is independently associated with survival in patients with ARDS. The Kigali adaptation of the Berlin ARDS definition may provide useful insights into the burden of ARDS in the developing world. ARDS exerts a substantial disease burden, with 40% of patients dying in hospital. Diverse factors, including patient-related factors such as age and illness severity, country level socioeconomic status, and ventilator management and ICU organizational factors each contribute to outcome from ARDS. Addressing these issues provides opportunities to improve outcome in patients with ARDS.

  12. Epidemiological characteristics, practice of ventilation, and clinical outcome in patients at risk of acute respiratory distress syndrome in intensive care units from 16 countries (PRoVENT): an international, multicentre, prospective study.

    PubMed

    Neto, Ary Serpa; Barbas, Carmen S V; Simonis, Fabienne D; Artigas-Raventós, Antonio; Canet, Jaume; Determann, Rogier M; Anstey, James; Hedenstierna, Goran; Hemmes, Sabrine N T; Hermans, Greet; Hiesmayr, Michael; Hollmann, Markus W; Jaber, Samir; Martin-Loeches, Ignacio; Mills, Gary H; Pearse, Rupert M; Putensen, Christian; Schmid, Werner; Severgnini, Paolo; Smith, Roger; Treschan, Tanja A; Tschernko, Edda M; Melo, Marcos F V; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2016-11-01

    Scant information exists about the epidemiological characteristics and outcome of patients in the intensive care unit (ICU) at risk of acute respiratory distress syndrome (ARDS) and how ventilation is managed in these individuals. We aimed to establish the epidemiological characteristics of patients at risk of ARDS, describe ventilation management in this population, and assess outcomes compared with people at no risk of ARDS. PRoVENT (PRactice of VENTilation in critically ill patients without ARDS at onset of ventilation) is an international, multicentre, prospective study undertaken at 119 ICUs in 16 countries worldwide. All patients aged 18 years or older who were receiving mechanical ventilation in participating ICUs during a 1-week period between January, 2014, and January, 2015, were enrolled into the study. The Lung Injury Prediction Score (LIPS) was used to stratify risk of ARDS, with a score of 4 or higher defining those at risk of ARDS. The primary outcome was the proportion of patients at risk of ARDS. Secondary outcomes included ventilatory management (including tidal volume [V T ] expressed as mL/kg predicted bodyweight [PBW], and positive end-expiratory pressure [PEEP] expressed as cm H 2 O), development of pulmonary complications, and clinical outcomes. The PRoVENT study is registered at ClinicalTrials.gov, NCT01868321. The study has been completed. Of 3023 patients screened for the study, 935 individuals fulfilled the inclusion criteria. Of these critically ill patients, 282 were at risk of ARDS (30%, 95% CI 27-33), representing 0·14 cases per ICU bed over a 1-week period. V T was similar for patients at risk and not at risk of ARDS (median 7·6 mL/kg PBW [IQR 6·7-9·1] vs 7·9 mL/kg PBW [6·8-9·1]; p=0·346). PEEP was higher in patients at risk of ARDS compared with those not at risk (median 6·0 cm H 2 O [IQR 5·0-8·0] vs 5·0 cm H 2 O [5·0-7·0]; p<0·0001). The prevalence of ARDS in patients at risk of ARDS was higher than in individuals

  13. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach.

    PubMed

    Biais, Matthieu; Ehrmann, Stephan; Mari, Arnaud; Conte, Benjamin; Mahjoub, Yazine; Desebbe, Olivier; Pottecher, Julien; Lakhal, Karim; Benzekri-Lefevre, Dalila; Molinari, Nicolas; Boulain, Thierry; Lefrant, Jean-Yves; Muller, Laurent

    2014-11-04

    Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P<0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg(-1) and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.

  14. Aerial secure display by use of polarization-processing display with retarder film and retro-reflector

    NASA Astrophysics Data System (ADS)

    Ito, Shusei; Uchida, Keitaro; Mizushina, Haruki; Suyama, Shiro; Yamamoto, Hirotsugu

    2017-02-01

    Security is one of the big issues in automated teller machine (ATM). In ATM, two types of security have to be maintained. One is to secure displayed information. The other is to secure screen contamination. This paper gives a solution for these two security issues. In order to secure information against peeping at the screen, we utilize visual cryptography for displayed information and limit the viewing zone. Furthermore, an aerial information screen with aerial imaging by retro-reflection, named AIRR enables users to avoid direct touch on the information screen. The purpose of this paper is to propose an aerial secure display technique that ensures security of displayed information as well as security against contamination problem on screen touch. We have developed a polarization-processing display that is composed of a backlight, a polarizer, a background LCD panel, a gap, a half-wave retarder, and a foreground LCD panel. Polarization angle is rotated with the LCD panels. We have constructed a polarization encryption code set. Size of displayed images are designed to limit the viewing position. Furthermore, this polarization-processing display has been introduced into our aerial imaging optics, which employs a reflective polarizer and a retro-reflector covered with a quarter-wave retarder. Polarization-modulated light forms the real image over the reflective polarizer. We have successfully formed aerial information screen that shows the secret image with a limited viewing position. This is the first realization of aerial secure display by use of polarization-processing display with retarder-film and retro-reflector.

  15. How does the presence of a conspecific individual change the behavioral game that a predator plays with its prey?

    PubMed

    Vardi, Reut; Abramsky, Zvika; Kotler, Burt P; Altstein, Ofir; Rosenzweig, Michael L

    2017-07-01

    Behavioral games predators play among themselves may have profound effects on behavioral games predators play with their prey. We studied the behavioral game between predators and prey within the framework of social foraging among predators. We tested how conspecific interactions among predators (little egret) change the predator-prey behavioral game and foraging success. To do so, we examined foraging behavior of egrets alone and in pairs (male and female) in a specially designed aviary consisting of three equally spaced pools with identical initial prey (comet goldfish) densities. Each pool was comprised of a risky microhabitat, rich with food, and a safe microhabitat with no food, forcing the fish to trade off food and safety. When faced with two versus one egret, we found that fish significantly reduced activity in the risky habitat. Egrets in pairs suffered reduced foraging success (negative intraspecific density dependence) and responded to fish behavior and to their conspecific by changing their visiting regime at the different pools-having shorter, more frequent visits. The time egret spent on each visit allowed them to match their long-term capture success rate across the environment to their capture success rate in the pool, which satisfies one aspect of optimality. Overall, egrets in pairs allocated more time for foraging and changed their foraging tactics to focus more on fish under cover and fish 'peeping' out from their shelter. These results suggest that both prey and predator show behavioral flexibility and can adjust to changing conditions as needed in this foraging game.

  16. Mild hypothermia increases pulmonary anti-inflammatory response during protective mechanical ventilation in a piglet model of acute lung injury.

    PubMed

    Cruces, Pablo; Erranz, Benjamín; Donoso, Alejandro; Carvajal, Cristóbal; Salomón, Tatiana; Torres, María Fernanda; Díaz, Franco

    2013-11-01

    The effects of mild hypothermia (HT) on acute lung injury (ALI) are unknown in species with metabolic rate similar to that of humans, receiving protective mechanical ventilation (MV). We hypothesized that mild hypothermia would attenuate pulmonary and systemic inflammatory responses in piglets with ALI managed with a protective MV. Acute lung injury (ALI) was induced with surfactant deactivation in 38 piglets. The animals were then ventilated with low tidal volume, moderate positive end-expiratory pressure (PEEP), and permissive hypercapnia throughout the experiment. Subjects were randomized to HT (33.5°C) or normothermia (37°C) groups over 4 h. Plasma and tissue cytokines, tissue apoptosis, lung mechanics, pulmonary vascular permeability, hemodynamic, and coagulation were evaluated. Lung interleukin-10 concentrations were higher in subjects that underwent HT after ALI induction than in those that maintained normothermia. No difference was found in other systemic and tissue cytokines. HT did not induce lung or kidney tissue apoptosis or influence lung mechanics or markers of pulmonary vascular permeability. Heart rate, cardiac output, oxygen uptake, and delivery were significantly lower in subjects that underwent HT, but no difference in arterial lactate, central venous oxygen saturation, and coagulation test was observed. Mild hypothermia induced a local anti-inflammatory response in the lungs, without affecting lung function or coagulation, in this piglet model of ALI. The HT group had lower cardiac output without signs of global dysoxia, suggesting an adaptation to the decrease in oxygen uptake and delivery. Studies are needed to determine the therapeutic role of HT in ALI. © 2013 John Wiley & Sons Ltd.

  17. Perioperative lung protective ventilation in obese patients.

    PubMed

    Fernandez-Bustamante, Ana; Hashimoto, Soshi; Serpa Neto, Ary; Moine, Pierre; Vidal Melo, Marcos F; Repine, John E

    2015-05-06

    The perioperative use and relevance of protective ventilation in surgical patients is being increasingly recognized. Obesity poses particular challenges to adequate mechanical ventilation in addition to surgical constraints, primarily by restricted lung mechanics due to excessive adiposity, frequent respiratory comorbidities (i.e. sleep apnea, asthma), and concerns of postoperative respiratory depression and other pulmonary complications. The number of surgical patients with obesity is increasing, and facing these challenges is common in the operating rooms and critical care units worldwide. In this review we summarize the existing literature which supports the following recommendations for the perioperative ventilation in obese patients: (1) the use of protective ventilation with low tidal volumes (approximately 8 mL/kg, calculated based on predicted -not actual- body weight) to avoid volutrauma; (2) a focus on lung recruitment by utilizing PEEP (8-15 cmH2O) in addition to recruitment maneuvers during the intraoperative period, as well as incentivized deep breathing and noninvasive ventilation early in the postoperative period, to avoid atelectasis, hypoxemia and atelectrauma; and (3) a judicious oxygen use (ideally less than 0.8) to avoid hypoxemia but also possible reabsorption atelectasis. Obesity poses an additional challenge for achieving adequate protective ventilation during one-lung ventilation, but different lung isolation techniques have been adequately performed in obese patients by experienced providers. Postoperative efforts should be directed to avoid hypoventilation, atelectasis and hypoxemia. Further studies are needed to better define optimum protective ventilation strategies and analyze their impact on the perioperative outcomes of surgical patients with obesity.

  18. High-frequency percussive ventilation attenuates lung injury in a rabbit model of gastric juice aspiration.

    PubMed

    Allardet-Servent, Jérôme; Bregeon, Fabienne; Delpierre, Stéphane; Steinberg, Jean-Guillaume; Payan, Marie-José; Ravailhe, Sylvie; Papazian, Laurent

    2008-01-01

    To test the effects of high-frequency percussive ventilation (HFPV) compared with high-frequency oscillatory ventilation (HFOV) and low-volume conventional mechanical ventilation (LVCMV), on lung injury course in a gastric juice aspiration model. Prospective, randomized, controlled, in-vivo animal study. University animal research laboratory. Forty-three New Zealand rabbits. Lung injury was induced by intratracheal instillation of human gastric juice in order to achieve profound hypoxaemia (PaO2/FIO2< or =50). Animals were ventilated for 4h after randomization in one of the following four groups: HFPV (median pressure 15cmH2O); LVCMV (VT 6mlkg(-1) and PEEP set to reach 15cmH2O plateau pressure); HFOV (mean pressure 15cmH2O); and a high-volume control group HVCMV (VT 12ml kg(-1) and ZEEP). Static respiratory compliance increased after the ventilation period in the HFPV, LVMCV and HFOV groups, in contrast with the HVCMV group. PaO2/FIO2 improved similarly in the HFPV, LVCMV and HFOV groups, and remained lower in the HVCMV group than in the three others. Lung oedema, myeloperoxidase and histological lung injury score were higher in the HVCMV group, but not different among all others. Arterial lactate markedly increased after 4h of ventilation in the HVCMV group, while lower but similar levels were observed in the three other groups. HFPV, like HFOV and protective CMV, improves respiratory mechanics and oxygenation, and attenuates lung damage. The HFPV provides attractive lung protection, but further studies should confirm these results before introducing HFPV into the clinical arena.

  19. Ventilation in the patient with unilateral lung disease.

    PubMed

    Thomas, A R; Bryce, T L

    1998-10-01

    Severe ULD presents a challenge in ventilator management because of the marked asymmetry in the mechanics of the two lungs. The asymmetry may result from significant decreases or increases in the compliance of the involved lung. Traditional ventilator support may fail to produce adequate gas exchange in these situations and has the potential to cause further deterioration. Fortunately, conventional techniques can be safely and effectively applied in the majority of cases without having to resort to less familiar and potentially hazardous forms of support. In those circumstances when conventional ventilation is unsuccessful in restoring adequate gas exchange, lateral positioning and ILV have proved effective at improving and maintaining gas exchange. Controlled trials to guide clinical decision making are lacking. In patients who have processes associated with decreased compliance in the involved lung, lateral positioning may be a simple method of improving gas exchange but is associated with many practical limitations. ILV in these patients is frequently successful when differential PEEP is applied with the higher pressure to the involved lung. In patients in whom the pathology results in distribution of ventilation favoring the involved lung, particularly BPF, ILV can be used to supply adequate support while minimizing flow through the fistula and allowing it to close. The application of these techniques should be undertaken with an understanding of the pathophysiology of the underlying process; the reported experience with these techniques, including indications and successfully applied methods; and the potential problems encountered with their use. Fortunately, these modalities are infrequently required, but they provide a critical means of support when conventional techniques fail.

  20. Defensive behaviors and prosencephalic neurogenesis in pigeons (Columba livia) are affected by environmental enrichment in adulthood.

    PubMed

    Melleu, F F; Pinheiro, M V; Lino-de-Oliveira, C; Marino-Neto, J

    2016-05-01

    Neurogenesis in the adult brain appears to be phylogenetically conserved across the animal kingdom. In pigeons and other adult non-oscine birds, immature neurons are observed in several prosencephalic areas, suggesting that neurogenesis may participate in the control of different behaviors. The mechanisms controlling neurogenesis and its relevance to defensive behaviors in non-oscine birds remain elusive. Herein, the contribution of the environment to behavior and neurogenesis of pigeons was investigated. Adult pigeons (Columba livia, n = 6/group), housed in standard (SE) or enriched environment (EE) for 42 days, were exposed to an unfamiliar environment (UE) followed by presentation to a novel object (NO). Video recordings of UE+NO tests were analyzed and scored for latency, duration and frequency of angular head movements, peeping, grooming, immobility and locomotion. Twenty-four hours later, pigeons were submitted to the tonic immobility test (TI) and number of trials for TI and TI duration were scored, followed by euthanasia 2 h later. Brains were immunohistochemically processed to reveal doublecortin (DCX), a marker for newborn neurons. Compared to those housed in SE, the pigeons housed in EE responded to a NO with more immobility. In addition, the pigeons housed in EE presented longer TI, more DCX-immunoreactive (DCX-ir) cells in the hippocampus and fewer DCX-ir cells in the lateral striatum than those housed in SE. There was no correlation between the number of DCX-ir cells and the scores of immobility in behavioral tests. Together, these data suggest that enrichment favored behavioral inhibition and neurogenesis in the adult pigeons through different, parallel mechanisms.

  1. Resolved versus confirmed ARDS after 24 h: insights from the LUNG SAFE study.

    PubMed

    Madotto, Fabiana; Pham, Tài; Bellani, Giacomo; Bos, Lieuwe D; Simonis, Fabienne D; Fan, Eddy; Artigas, Antonio; Brochard, Laurent; Schultz, Marcus J; Laffey, John G

    2018-04-09

    To evaluate patients with resolved versus confirmed ARDS, identify subgroups with substantial mortality risk, and to determine the utility of day 2 ARDS reclassification. Our primary objective, in this secondary LUNG SAFE analysis, was to compare outcome in patients with resolved versus confirmed ARDS after 24 h. Secondary objectives included identifying factors associated with ARDS persistence and mortality, and the utility of day 2 ARDS reclassification. Of 2377 patients fulfilling the ARDS definition on the first day of ARDS (day 1) and receiving invasive mechanical ventilation, 503 (24%) no longer fulfilled the ARDS definition the next day, 52% of whom initially had moderate or severe ARDS. Higher tidal volume on day 1 of ARDS was associated with confirmed ARDS [OR 1.07 (CI 1.01-1.13), P = 0.035]. Hospital mortality was 38% overall, ranging from 31% in resolved ARDS to 41% in confirmed ARDS, and 57% in confirmed severe ARDS at day 2. In both resolved and confirmed ARDS, age, non-respiratory SOFA score, lower PEEP and P/F ratio, higher peak pressure and respiratory rate were each associated with mortality. In confirmed ARDS, pH and the presence of immunosuppression or neoplasm were also associated with mortality. The increase in area under the receiver operating curve for ARDS reclassification on day 2 was marginal. ARDS, whether resolved or confirmed at day 2, has a high mortality rate. ARDS reclassification at day 2 has limited predictive value for mortality. The substantial mortality risk in severe confirmed ARDS suggests that complex interventions might best be tested in this population. ClinicalTrials.gov NCT02010073.

  2. Ten new species of Oreophryne (Anura, Microhylidae) from Papua New Guinea.

    PubMed

    Kraus, Fred

    2016-11-17

    Oreophryne presently represents the second-most-diverse genus of microhylid frogs, with 57 named species, most occurring on New Guinea and its satellite islands. Nonetheless, a diversity of species remains to be described. Using morphological, color-pattern, and advertisement-call data, I describe ten new species of Oreophryne from the Papuan Peninsula of New Guinea and adjacent islands, which together form the East Papuan Composite Terrane. All but two of these species can be placed into two species groups based on call type. I refer to these species groups as the O. anser group and the O. equus group, both being based on species described herein. Members of the O. anser group produce calls reminiscent of a goose honk, whereas members of the O. equus group produce calls reminiscent of a horse's whinny. Description of three new species in the O. anser group requires me to first rediagnose O. loriae, which has previously been interpreted as including the frogs named herein as O. anser sp. nov. The honk call type has not previously been reported within Oreophryne, and the whinny call may be novel as well, although it is possibly derived from other New Guinean species having calls consisting of a slower series of peeps. Based on their unique call types, I hypothesize that both species groups are monophyletic. If true, each would appear endemic to the East Papuan Composite Terrane. Only five additional species of Oreophryne are known from this region that do not belong to one or the other of these two species groups; hence, these newly identified species groups represent the majority of diversity in Oreophryne from the Papuan Peninsula and its satellite islands.

  3. [FRC measurement in intensive care patients. A definition of standards].

    PubMed

    Wauer, H J; Lorenz, B A; Kox, W J

    1998-10-01

    Determination of Functional Residual Capacity (FRC) can be performed through washout methods, indicator gas dilution or bodyplethysmography. Some of these techniques have been adapted for use in intensive care patients whilst being mechanically ventilated. However, most measurement setups are bulky, cumbersome to use and their running costs are high. Hence FRC measurement has not become a routine method in intensive care although it offers considerable advantages in the management of ventilated patients such as the determination of "best PEEP", the detection of progressive alveolar collapse in the course of acute lung injury and during weaning from mechanical ventilation. Up to now most efforts to improve and simplify FRC measurement were made at the expense of accuracy. An ideal method ought to be accurate, easy to handle and cost-effective. It should supply not only FRC data but also information about intrapulmonary gas distribution and dead space. These demands can be met using modern data acquisition software. The pros and cons of all methods available for FRC measurement are discussed in view of their suitability for intensive care patients. A conventional nitrogen washout using emission spectroscopy for measurement of nitrogen concentration gives satisfying exact values for the determination of the parameters mentioned above. The measurement error can be lowered under 5% by special corrections for flow and nitrogen signal (delay and rise times, changes of gas viscosity). For flow measurement a normal pneumotachograph can be used. Using a laptop computer for data acquisition the bed-side monitor fulfills most of the demands in intensive care. It is then also possible to measure indices of intrapulmonary gas distribution such as Alveolar Mixing Efficiency and Lung Clearance Index.

  4. The use of continuous positive airway pressure in preterm babies with respiratory distress syndrome: a report from Baghdad, Iraq.

    PubMed

    Hameed, Numan Nafie; Abdul Jaleel, Ra'id Khalil; Saugstad, Ola Didrik

    2014-04-01

    To study maternal and neonatal risk factors related to outcome of preterm babies with respiratory distress syndrome (RDS) on Continuous Positive Airway Pressure (CPAP) in a tertiary Iraqi NICU. A prospective case study carried out from January 5, 2011 to January 5, 2012, on 70 preterm neonates with RDS who were started on CPAP. Maternal and infant variables of preterm babies with successful or failed CPAP therapy were compared. Seventy neonates, 44 (63%) males and 26 (37%) females were included. Mean (SD) gestation was 32.8 (2.8) weeks and mean (SD) birth weight was 1860 (656) g. Thirty-seven (52.9%) babies failed CPAP, of them 29 (78.3%) were started on mechanical ventilation. The variables associated with failure of CPAP were: Birth weight ≤1500 g, gestational age ≤30 weeks, white out on the chest X-ray, FiO2 ≥50% at 20 min of CPAP, PEEP ≥5.5 cm H2O. Mortality rates were 94.6% in CPAP failures versus 5.4% in CPAP successes (p = 0.001). In infants surviving till discharge, duration of hospital stay was longer in babies who were CPAP successes (9.6 ± 3.7 versus 3.0 ± 2.7 days, p = 0.001). Gestational age, birth weight, whiteout chest X-ray, and FiO2 are important predictive values for success of CPAP therapy. A larger prospective multicenter controlled trial is needed to determine the benefits and risks of CPAP and predictors of its failure in our setting. Our results may be useful for others practicing in similar settings as us.

  5. PREOXYGENATION: COULD SAFETY MEASURE BE MADE LESS DANGEROUS?.

    PubMed

    Kamenskaya, L U; Lebedinskiy, K M

    2016-11-01

    While providing reserve time for dificult airway management, preoxygenation with pure oxygen increases the risk of pulmonary complications due to absorption atelectases. The authors explored when it could be appropriate to prevent atelectases by preoxygenation with decreased FiO₂. ASA I-II elective gynecological surgery patients were randomized among five groups (n = 22 each) with preoxygenation using FiO₂ 100, 70, 60, 60% + PEEP 5 mbar and 50%. Even FiO₂ 70% led to decrease. in safe apnea time (i.e. time interval to Sp²O₂ 95%) by two, while FiO₂ 50% - by more than three times. Furthermore, in five similar additional groups of women with same techniques ofpreoxygenation (n = 10 each) it was shown that for FiO₂ 5 70% very fast pattern of SpO2 fall after the first change ofpulseoxymeter figure (100% by 99%) is typical: interval to SpO2 90% was less than 1 min, while for FiO₂ 100% it lasts for 200 s. Since critical problem is "Cannot intubate, cannot ventilate", the authors tried to focus on the difficultfacemask ventilation prognosis. In the group of 71 elective general surgery patients (31 males, 40 females, ASA I-III) original prognostic model based on seven simple bedside tests (removable dentures, beard, snoring, Mallampati class 2-4, age > 50 y.o., BM > 30 kg/m², sternomental distance < 12 cm) demonstrated the reliability of difficult facemask ventilation negative prognosis of 97,5%. The authors suggest that only in patients with reliable prognosis of easy facemask ventilation prevention ofpulmonary complications by preoxygenation with FiO₂ 50-60% could be safely recommended.

  6. USE OF POSITIVE PRESSURE IN THE BARIATRIC SURGERY AND EFFECTS ON PULMONARY FUNCTION AND PREVALENCE OF ATELECTASIS: RANDOMIZED AND BLINDED CLINICAL TRIAL

    PubMed Central

    BALTIERI, Letícia; SANTOS, Laisa Antonela; RASERA-JUNIOR, Irineu; MONTEBELO, Maria Imaculada Lima; PAZZIANOTTO-FORTI, Eli Maria

    2014-01-01

    Background In surgical procedures, obesity is a risk factor for the onset of intra and postoperative respiratory complications. Aim Determine what moment of application of positive pressure brings better benefits on lung function, incidence of atelectasis and diaphragmatic excursion, in the preoperative, intraoperative or immediate postoperative period. Method Randomized, controlled, blinded study, conducted in a hospital and included subjects with BMI between 40 and 55 kg/m2, 25 and 55 years, underwent bariatric surgery by laparotomy. They were underwent preoperative and postoperative evaluations. They were allocated into four different groups: 1) Gpre: treated with positive pressure in the BiPAP mode (Bi-Level Positive Airway Pressure) before surgery for one hour; 2) Gpos: BIPAP after surgery for one hour; 3) Gintra: PEEP (Positive End Expiratory Pressure) at 10 cmH2O during the surgery; 4) Gcontrol: only conventional respiratory physiotherapy. The evaluation consisted of anthropometric data, pulmonary function tests and chest radiography. Results Were allocated 40 patients, 10 in each group. There were significant differences for the expiratory reserve volume and percentage of the predicted expiratory reserve volume, in which the groups that received treatment showed a smaller loss in expiratory reserve volume from the preoperative to postoperative stages. The postoperative radiographic analysis showed a 25% prevalence of atelectasis for Gcontrol, 11.1% for Gintra, 10% for Gpre, and 0% for Gpos. There was no significant difference in diaphragmatic mobility amongst the groups. Conclusion The optimal time of application of positive pressure is in the immediate postoperative period, immediately after extubation, because it reduces the incidence of atelectasis and there is reduction of loss of expiratory reserve volume. PMID:25409961

  7. Use of positive pressure in the bariatric surgery and effects on pulmonary function and prevalence of atelectasis: randomized and blinded clinical trial.

    PubMed

    Baltieri, Letícia; Santos, Laisa Antonela; Rasera, Irineu; Montebelo, Maria Imaculada Lima; Pazzianotto-Forti, Eli Maria

    2014-01-01

    In surgical procedures, obesity is a risk factor for the onset of intra and postoperative respiratory complications. Determine what moment of application of positive pressure brings better benefits on lung function, incidence of atelectasis and diaphragmatic excursion, in the preoperative, intraoperative or immediate postoperative period. Randomized, controlled, blinded study, conducted in a hospital and included subjects with BMI between 40 and 55 kg/m2, 25 and 55 years, underwent bariatric surgery by laparotomy. They were underwent preoperative and postoperative evaluations. They were allocated into four different groups: 1) Gpre: treated with positive pressure in the BiPAP mode (Bi-Level Positive Airway Pressure) before surgery for one hour; 2) Gpos: BIPAP after surgery for one hour; 3) Gintra: PEEP (Positive End Expiratory Pressure) at 10 cmH2O during the surgery; 4) Gcontrol: only conventional respiratory physiotherapy. The evaluation consisted of anthropometric data, pulmonary function tests and chest radiography. Were allocated 40 patients, 10 in each group. There were significant differences for the expiratory reserve volume and percentage of the predicted expiratory reserve volume, in which the groups that received treatment showed a smaller loss in expiratory reserve volume from the preoperative to postoperative stages. The postoperative radiographic analysis showed a 25% prevalence of atelectasis for Gcontrol, 11.1% for Gintra, 10% for Gpre, and 0% for Gpos. There was no significant difference in diaphragmatic mobility amongst the groups. The optimal time of application of positive pressure is in the immediate postoperative period, immediately after extubation, because it reduces the incidence of atelectasis and there is reduction of loss of expiratory reserve volume.

  8. Variable versus conventional lung protective mechanical ventilation during open abdominal surgery (PROVAR): a randomised controlled trial.

    PubMed

    Spieth, P M; Güldner, A; Uhlig, C; Bluth, T; Kiss, T; Conrad, C; Bischlager, K; Braune, A; Huhle, R; Insorsi, A; Tarantino, F; Ball, L; Schultz, M J; Abolmaali, N; Koch, T; Pelosi, P; Gama de Abreu, M

    2018-03-01

    Experimental studies showed that controlled variable ventilation (CVV) yielded better pulmonary function compared to non-variable ventilation (CNV) in injured lungs. We hypothesized that CVV improves intraoperative and postoperative respiratory function in patients undergoing open abdominal surgery. Fifty patients planned for open abdominal surgery lasting >3 h were randomly assigned to receive either CVV or CNV. Mean tidal volumes and PEEP were set at 8 ml kg -1 (predicted body weight) and 5 cm H 2 O, respectively. In CVV, tidal volumes varied randomly, following a normal distribution, on a breath-by-breath basis. The primary endpoint was the forced vital capacity (FVC) on postoperative Day 1. Secondary endpoints were oxygenation, non-aerated lung volume, distribution of ventilation, and pulmonary and extrapulmonary complications until postoperative Day 5. FVC did not differ significantly between CVV and CNV on postoperative Day 1, 61.5 (standard deviation 22.1) % vs 61.9 (23.6) %, respectively; mean [95% confidence interval (CI)] difference, -0.4 (-13.2-14.0), P=0.95. Intraoperatively, CVV did not result in improved respiratory function, haemodynamics, or redistribution of ventilation compared to CNV. Postoperatively, FVC, forced expiratory volume at the first second (FEV 1 ), and FEV 1 /FVC deteriorated, while atelectasis volume and plasma levels of interleukin-6 and interleukin-8 increased, but values did not differ between groups. The incidence of postoperative pulmonary and extrapulmonary complications was comparable in CVV and CNV. In patients undergoing open abdominal surgery, CVV did not improve intraoperative and postoperative respiratory function compared with CNV. NCT 01683578. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  9. Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO2 removal versus 'conventional' protective ventilation (6 ml/kg) in severe ARDS: the prospective randomized Xtravent-study.

    PubMed

    Bein, Thomas; Weber-Carstens, Steffen; Goldmann, Anton; Müller, Thomas; Staudinger, Thomas; Brederlau, Jörg; Muellenbach, Ralf; Dembinski, Rolf; Graf, Bernhard M; Wewalka, Marlene; Philipp, Alois; Wernecke, Klaus-Dieter; Lubnow, Matthias; Slutsky, Arthur S

    2013-05-01

    Acute respiratory distress syndrome is characterized by damage to the lung caused by various insults, including ventilation itself, and tidal hyperinflation can lead to ventilator induced lung injury (VILI). We investigated the effects of a low tidal volume (V(T)) strategy (V(T) ≈ 3 ml/kg/predicted body weight [PBW]) using pumpless extracorporeal lung assist in established ARDS. Seventy-nine patients were enrolled after a 'stabilization period' (24 h with optimized therapy and high PEEP). They were randomly assigned to receive a low V(T) ventilation (≈3 ml/kg) combined with extracorporeal CO2 elimination, or to a ARDSNet strategy (≈6 ml/kg) without the extracorporeal device. The primary outcome was the 28-days and 60-days ventilator-free days (VFD). Secondary outcome parameters were respiratory mechanics, gas exchange, analgesic/sedation use, complications and hospital mortality. Ventilation with very low V(T)'s was easy to implement with extracorporeal CO2-removal. VFD's within 60 days were not different between the study group (33.2 ± 20) and the control group (29.2 ± 21, p = 0.469), but in more hypoxemic patients (PaO2/FIO2 ≤150) a post hoc analysis demonstrated significant improved VFD-60 in study patients (40.9 ± 12.8) compared to control (28.2 ± 16.4, p = 0.033). The mortality rate was low (16.5%) and did not differ between groups. The use of very low V(T) combined with extracorporeal CO2 removal has the potential to further reduce VILI compared with a 'normal' lung protective management. Whether this strategy will improve survival in ARDS patients remains to be determined (Clinical trials NCT 00538928).

  10. Flow-controlled expiration: a novel ventilation mode to attenuate experimental porcine lung injury.

    PubMed

    Goebel, U; Haberstroh, J; Foerster, K; Dassow, C; Priebe, H-J; Guttmann, J; Schumann, S

    2014-09-01

    Whereas the effects of various inspiratory ventilatory modifications in lung injury have extensively been studied, those of expiratory ventilatory modifications are less well known. We hypothesized that the newly developed flow-controlled expiration (FLEX) mode provides a means of attenuating experimental lung injury. Experimental acute respiratory distress syndrome was induced by i.v. injection of oleic acid in 15 anaesthetized and mechanically ventilated pigs. After established lung injury ([Formula: see text]ratio <27 kPa), animals were randomized to either a control group receiving volume-controlled ventilation (VCV) or a treatment group receiving VCV with additional FLEX (VCV+FLEX). At predefined times, lung mechanics and oxygenation were assessed. At the end of the experiment, the pigs were killed, and bronchoalveolar fluid and lung biopsies were taken. Expression of inflammatory cytokines was analysed in lung tissue and bronchoalveolar fluid. Lung injury score was determined on the basis of stained tissue samples. Compared with the control group (VCV; n=8), the VCV+FLEX group (n=7) demonstrated greater dynamic lung compliance and required less PEEP at comparable [Formula: see text] (both P<0.05), had lower regional lung wet-to-dry ratios and lung injury scores (both P<0.001), and showed less thickening of alveolar walls (an indicator of interstitial oedema) and de novo migration of macrophages into lung tissue (both P<0.001). The newly developed FLEX mode is able to attenuate experimental lung injury. FLEX could provide a novel means of lung-protective ventilation. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Genetic deletion of apolipoprotein A-I increases airway hyperresponsiveness, inflammation, and collagen deposition in the lung

    PubMed Central

    Wang, Weiling; Xu, Hao; Shi, Yang; Nandedkar, Sandhya; Zhang, Hao; Gao, Haiqing; Feroah, Thom; Weihrauch, Dorothee; Schulte, Marie L.; Jones, Deron W.; Jarzembowski, Jason; Sorci-Thomas, Mary; Pritchard, Kirkwood A.

    2010-01-01

    The relationship between high-density lipoprotein and pulmonary function is unclear. To determine mechanistic relationships we investigated the effects of genetic deletion of apolipoprotein A-I (apoA-I) on plasma lipids, paraoxonase (PON1), pro-inflammatory HDL (p-HDL), vasodilatation, airway hyperresponsiveness and pulmonary oxidative stress, and inflammation. ApoA-I null (apoA-I−/−) mice had reduced total and HDL cholesterol but increased pro-inflammatory HDL compared with C57BL/6J mice. Although PON1 protein was increased in apoA-I−/− mice, PON1 activity was decreased. ApoA-I deficiency did not alter vasodilatation of facialis arteries, but it did alter relaxation responses of pulmonary arteries. Central airway resistance was unaltered. However, airway resistance mediated by tissue dampening and elastance were increased in apoA-I−/− mice, a finding also confirmed by positive end-expiratory pressure (PEEP) studies. Inflammatory cells, collagen deposition, 3-nitrotyrosine, and 4-hydroxy-2-nonenal were increased in apoA-I−/− lungs but not oxidized phospholipids. Colocalization of 4-hydroxy-2-nonenal with transforming growth factor β-1 (TGFβ-1 was increased in apoA-I−/− lungs. Xanthine oxidase, myeloperoxidase and endothelial nitric oxide synthase were increased in apoA-I−/− lungs. Dichlorodihydrofluorescein-detectable oxidants were increased in bronchoalveolar lavage fluid (BALF) in apoA-I−/− mice. In contrast, BALF nitrite+nitrate levels were decreased in apoA-I−/− mice. These data demonstrate that apoA-I plays important roles in limiting pulmonary inflammation and oxidative stress, which if not prevented, will decrease pulmonary artery vasodilatation and increase airway hyperresponsiveness. PMID:20498409

  12. The ALIEN study: incidence and outcome of acute respiratory distress syndrome in the era of lung protective ventilation.

    PubMed

    Villar, Jesús; Blanco, Jesús; Añón, José Manuel; Santos-Bouza, Antonio; Blanch, Lluís; Ambrós, Alfonso; Gandía, Francisco; Carriedo, Demetrio; Mosteiro, Fernando; Basaldúa, Santiago; Fernández, Rosa Lidia; Kacmarek, Robert M

    2011-12-01

    While our understanding of the pathogenesis and management of acute respiratory distress syndrome (ARDS) has improved over the past decade, estimates of its incidence have been controversial. The goal of this study was to examine ARDS incidence and outcome under current lung protective ventilatory support practices before and after the diagnosis of ARDS. This was a 1-year prospective, multicenter, observational study in 13 geographical areas of Spain (serving a population of 3.55 million at least 18 years of age) between November 2008 and October 2009. Subjects comprised all consecutive patients meeting American-European Consensus Criteria for ARDS. Data on ventilatory management, gas exchange, hemodynamics, and organ dysfunction were collected. A total of 255 mechanically ventilated patients fulfilled the ARDS definition, representing an incidence of 7.2/100,000 population/year. Pneumonia and sepsis were the most common causes of ARDS. At the time of meeting ARDS criteria, mean PaO(2)/FiO(2) was 114 ± 40 mmHg, mean tidal volume was 7.2 ± 1.1 ml/kg predicted body weight, mean plateau pressure was 26 ± 5 cmH(2)O, and mean positive end-expiratory pressure (PEEP) was 9.3 ± 2.4 cmH(2)O. Overall ARDS intensive care unit (ICU) and hospital mortality was 42.7% (95%CI 37.7-47.8) and 47.8% (95%CI 42.8-53.0), respectively. This is the first study to prospectively estimate the ARDS incidence during the routine application of lung protective ventilation. Our findings support previous estimates in Europe and are an order of magnitude lower than those reported in the USA and Australia. Despite use of lung protective ventilation, overall ICU and hospital mortality of ARDS patients is still higher than 40%.

  13. [Microcuff pediatric tracheal tube. A new tracheal tube with a high volume-low pressure cuff for children].

    PubMed

    Weiss, M; Dullenkopf, A; Gerber, A C

    2004-01-01

    Principles and characteristics of the recently introduced Microcuff paediatric tracheal tube (Microcuff, GmbH, Weinheim, Germany) with anatomically based depth markings, cuff-free subglottic tube shaft and short high volume-low pressure cuff with ultrathin cuff membrane are presented. First available tubes (ID 4.0 mm) were evaluated regarding cuff pressures required to seal the trachea and regarding the distance from the tube tip to the carina. After obtaining approval of the local ethical committee, 20 children aged 2-4 years, receiving tracheal intubation under general anaesthesia with muscle paralysis, were included. The tubes were placed during direct laryngoscopy and the glottic depth marking placed between the vocal cords. Cuff pressure to prevent audible air leakage at standardised ventilator settings (PIP 20 cm H(2)O/PEEP 5 cm H(2)O/RR20 x min(-1)) was assessed by means of a cuff pressure manometer within 5 min after intubation. Subsequently, the distance from the tube tip to the tracheal carina was measured by means of fibre bronchoscopy. Data are presented as the median (range). Patient age was 3.0 years (2.0-3.9 years), weight 13.5 kg (9.1-19.2 kg) and body length 95 cm (79-105 cm). The lowest cuff pressure required to seal the trachea ranged from 4-14 cmH(2)O (median 10 cm H(2)O), the distance from tube tip to tracheal carina was to 2.9 cm (2.0-4.5 cm). The new Microcuff paediatric tracheal tube with ultrathin high volume-low pressure cuff required tracheal sealing pressures below tracheal wall pressures usually required with uncuffed tracheal tubes for efficient sealing and ventilation at 20 cm H(2)O peak inspiratory pressure. The distance from the tube tip to carina was in the safe range in all patients.

  14. Effects of inspiratory pause on CO2 elimination and arterial PCO2 in acute lung injury

    PubMed Central

    Devaquet, Jérôme; Jonson, Björn; Niklason, Lisbet; Si Larbi, Anne-Gaëlle; Uttman, Leif; Aboab, Jérôme; Brochard, Laurent

    2008-01-01

    A high respiratory rate associated with the use of small tidal volumes, recommended for acute lung injury (ALI), shortens time for gas diffusion in the alveoli. This may decrease CO2 elimination. We hypothesized that a post-inspiratory pause could enhance CO2 elimination and reduce PaCO2 by reducing dead space in ALI. In 15 mechanically ventilated patients with ALI and hypercapnia, a 20% post-inspiratory pause (Tp20) was applied during a period of 30 min between two ventilation periods without post-inspiratory pause (Tp0). Other parameters were kept unchanged. The single breath test for CO2 was recorded every 5 minutes to measure tidal CO2 elimination (VtCO2), airway dead space (VDaw) and slope of the alveolar plateau. PaO2, PaCO2, physiological and alveolar dead space (VDphys, VDalv) were determined at the end of each 30 minute period. The post-inspiratory pause, 0.7±0.2 s, induced on average less than 0.5 cm H2O of intrinsic PEEP. During Tp20, VtCO2 increased immediately by 28±10% (14±5 ml per breath compared to 11±4 for Tp0) and then decreased without reaching the initial value within 30 minutes. The addition of a post-inspiratory pause decreased significantly VDaw by 14% and VDphys by 11% with no change in VDalv. During Tp20, the slope of alveolar plateau initially fell to 65±10 % of baseline value and continued to decrease. Tp20 induced a 10±3% decrease in PaCO2 at 30 minutes (from 55±10 to 49±9 mmHg, p<0.001) with no significant variation in PaO2. Post-inspiratory pause has a significant influence on CO2 elimination when small tidal volumes are used during mechanical ventilation for ALI. PMID:18801962

  15. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device.

    PubMed

    Takala, J; Keinänen, O; Väisänen, P; Kari, A

    1989-10-01

    The performance of a new gas exchange monitor was assessed both in laboratory simulation and in ICU patients. Laboratory simulation using N2 and CO2 injections resulted in a mean error of 2 +/- 2% in CO2 production (VCO2) and 4 +/- 4% in oxygen consumption (VO2) in respirator measurements (n = 55) and in a mean error of 3 +/- 2% in VCO2 and 4 +/- 2% in VO2 in canopy measurements (n = 25). The mean error in RQ during ethanol burning was 2 +/- 2% in respirator measurements (n = 45) and 1 +/- 1% in canopy measurements. FIO2 had little effect on the accuracy of VCO2, whereas the accuracy on high rates of VO2 (VO2 = 400 ml/min) was reduced, when FIO2 increased: the error ranged from 1 +/- 1% to 6 +/- 1%, except at VO2 400 ml/min during FIO2 0.8, where the error was 16 +/- 3%. Neither peak airway pressure (+13 to +63 cm H2O) nor PEEP (0 to +20 cm H2O) had an effect on the accuracy. The highest level of minute ventilation studied (22.5 L/min) reduced the accuracy slightly (mean error of VCO2 4 +/- 1% and VO2 7 +/- 2%). In patients during controlled mechanical ventilation, increasing FIO2 from 0.4 to 0.6 had no effect on the results. VO2 was consistently higher by gas exchange than by the Fick principle: 16 +/- 9% during controlled ventilation (n = 20), 21 +/- 8% on synchronized intermittent mandatory ventilation (n = 10) and 25 +/- 8% during spontaneous breathing. We conclude that the device proved to be accurate for gas exchange measurements in the ICU.

  16. Sudden generalized lung atelectasis during thoracotomy following thoracic lavage in 3 dogs.

    PubMed

    Drynan, Eleanor; Musk, Gabrielle; Raisis, Anthea

    2012-08-01

    To describe sudden onset of generalized pulmonary atelectasis following thoracic lavage in 3 dogs. Thoracic lavage was performed following ligation of a patent ductus arteriosus in case 1, prior to closure of a large traumatic full thickness wound in the chest wall in case 2, and during investigation of an idiopathic spontaneous pneumothorax in case 3. In each case anesthesia and surgery were uneventful until thoracic lavage was performed, after which sudden generalized pulmonary atelectasis was observed. The atelectasis was visualized and was associated with oxyhemoglobin desaturation, decreased end-tidal carbon dioxide partial pressure (ETCO(2)), and a marked increase in the peak inspiratory pressure (PIP) required to achieve visible lung inflation. Occlusion of the endotracheal tube and cervical trachea was directly eliminated as the cause of atelectasis in cases 1 and 2, and indirectly eliminated in case 3. Improvement in pulmonary function occurred in all cases in response to increased PIP ± positive end expiratory pressure (PEEP). Generalized atelectasis should be considered a possible complication of thoracic lavage performed during thoracotomy. In the cases presented here, it is suspected that pre-existing reduction in lung volume (due to inadequate ventilation, surgical compression, absorption atelectasis) was exacerbated by the addition of the lavage fluid to the thoracic cavity. This pre-existing lung collapse is believed to have resulted in reduction of lung volume and that further reduction below the critical closing volume occurred following instillation of saline into the thorax resulting in the subsequent development of generalized atelectasis. The performance of regular arterial blood gas analyses and different ventilation protocols may have prevented the marked atelectasis that was observed in these cases. © Veterinary Emergency and Critical Care Society 2012.

  17. EARLY STABILIZING ALVEOLAR VENTILATION PREVENTS ARDS- A NOVEL TIMING-BASED VENTILATORY INTERVENTION TO AVERT LUNG INJURY

    PubMed Central

    Roy, Shreyas; Sadowitz, Benjamin; Andrews, Penny; Gatto, Louis; Marx, William; Ge, Lin; Wang, Guirong; Lin, Xin; Dean, David A.; Kuhn, Michael; Ghosh, Auyon; Satalin, Joshua; Snyder, Kathy; Vodovotz, Yoram; Nieman, Gary; Habashi, Nader

    2012-01-01

    Background Established ARDS is often refractory to treatment. Clinical trials have demonstrated modest treatment effects, and mortality remains high. Ventilator strategies must be developed to prevent ARDS. Hypothesis Early ventilatory intervention will block progression to ARDS if the ventilator mode: 1) maintains alveolar stability and 2) reduces pulmonary edema formation. Methods Yorkshire Pigs (38–45kg) were anaesthetized and subjected to "2-hit" Ischemia-Reperfusion and Peritoneal Sepsis. Following injury, animals were randomized into two groups: Early Preventative Ventilation (Airway Pressure Release Ventilation- APRV) vs. Non-Preventative Ventilation (NPV) and followed for 48hr. All animals received anesthesia, antibiotics, and fluid/vasopressor therapy per Surviving Sepsis Campaign. Ventilation parameters: 1) NPV Group - Tidal volume (Vt): 10cc/kg + PEEP- 5 cm/H2O volume-cycled mode, 2) APRV Group - Vt: 10–15 cc/kg; Phigh, Plow, Thigh, Tlow were titrated for optimal alveolar stability. Physiologic data and plasma were collected throughout the 48hr study period, followed by BAL and necropsy. Results APRV prevented development of ARDS (p<0.001 vs NPV) by PaO2/FiO2 ratio. Quantitative histological scoring showed APRV prevented lung tissue injury (p<0.001 vs. NPV). BALF showed APRV lowered total protein and IL-6, while preserving surfactant proteins A & B (p<0.05 vs. NPV). APRV significantly lowered lung water (p<0.001 vs. NPV). Plasma IL-6 concentrations were similar between groups. Conclusions Early preventative mechanical ventilation with APRV blocked ARDS development, preserved surfactant proteins, and reduced pulmonary inflammation and edema, despite systemic inflammation similar to NPV. These data suggest early preventative ventilation strategies stabilizing alveoli and reducing pulmonary edema can attenuate ARDS after ischemia-reperfusion-sepsis. PMID:22846945

  18. Variability in usual care mechanical ventilation for pediatric acute lung injury: the potential benefit of a lung protective computer protocol.

    PubMed

    Khemani, Robinder G; Sward, Katherine; Morris, Alan; Dean, J Michael; Newth, Christopher J L

    2011-11-01

    Although pediatric intensivists claim to embrace lung protective ventilation for acute lung injury (ALI), ventilator management is variable. We describe ventilator changes clinicians made for children with hypoxemic respiratory failure, and evaluate the potential acceptability of a pediatric ventilation protocol. This was a retrospective cohort study performed in a tertiary care pediatric intensive care unit (PICU). The study period was from January 2000 to July 2007. We included mechanically ventilated children with PaO(2)/FiO(2) (P/F) ratio less than 300. We assessed variability in ventilator management by evaluating actual changes to ventilator settings after an arterial blood gas (ABG). We evaluated the potential acceptability of a pediatric mechanical ventilation protocol we adapted from National Institutes of Health/National Heart, Lung, and Blood Institute (NIH/NHLBI) Acute Respiratory Distress Syndrome (ARDS) Network protocols by comparing actual practice changes in ventilator settings to changes that would have been recommended by the protocol. A total of 2,719 ABGs from 402 patients were associated with 6,017 ventilator settings. Clinicians infrequently decreased FiO(2), even when the PaO(2) was high (>68 mmHg). The protocol would have recommended more positive end expiratory pressure (PEEP) than was used in actual practice 42% of the time in the mid PaO(2) range (55-68 mmHg) and 67% of the time in the low PaO(2) range (<55 mmHg). Clinicians often made no change to either peak inspiratory pressure (PIP) or ventilator rate (VR) when the protocol would have recommended a change, even when the pH was greater than 7.45 with PIP at least 35 cmH(2)O. There may be lost opportunities to minimize potentially injurious ventilator settings for children with ALI. A reproducible pediatric mechanical ventilation protocol could prompt clinicians to make ventilator changes that are consistent with lung protective ventilation.

  19. Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies.

    PubMed

    Freitas, F G R; Bafi, A T; Nascente, A P M; Assunção, M; Mazza, B; Azevedo, L C P; Machado, F R

    2013-03-01

    The applicability of pulse pressure variation (ΔPP) to predict fluid responsiveness using lung-protective ventilation strategies is uncertain in clinical practice. We designed this study to evaluate the accuracy of this parameter in predicting the fluid responsiveness of septic patients ventilated with low tidal volumes (TV) (6 ml kg(-1)). Forty patients after the resuscitation phase of severe sepsis and septic shock who were mechanically ventilated with 6 ml kg(-1) were included. The ΔPP was obtained automatically at baseline and after a standardized fluid challenge (7 ml kg(-1)). Patients whose cardiac output increased by more than 15% were considered fluid responders. The predictive values of ΔPP and static variables [right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP)] were evaluated through a receiver operating characteristic (ROC) curve analysis. Thirty-four patients had characteristics consistent with acute lung injury or acute respiratory distress syndrome and were ventilated with high levels of PEEP [median (inter-quartile range) 10.0 (10.0-13.5)]. Nineteen patients were considered fluid responders. The RAP and PAOP significantly increased, and ΔPP significantly decreased after volume expansion. The ΔPP performance [ROC curve area: 0.91 (0.82-1.0)] was better than that of the RAP [ROC curve area: 0.73 (0.59-0.90)] and pulmonary artery occlusion pressure [ROC curve area: 0.58 (0.40-0.76)]. The ROC curve analysis revealed that the best cut-off for ΔPP was 6.5%, with a sensitivity of 0.89, specificity of 0.90, positive predictive value of 0.89, and negative predictive value of 0.90. Automatized ΔPP accurately predicted fluid responsiveness in septic patients ventilated with low TV.

  20. History and current status of mini-invasive thoracic surgery

    PubMed Central

    He, Jianxing

    2011-01-01

    Mini-invasive thoracic technique mainly refers to a technique involving the significant reduction of the chest wall access-related trauma. Notably, thoracoscope is the chief representative. The development of thoracoscope technique is characterized by: developing from direct peep to artificial lighting, then combination with image and video technique in equipments; technically developing from diagnostic to therapeutic approaches; developing from simpleness to complexity in application scope; and usually developing together with other techniques. At present, the widely used mini-invasive thoracic surgery refers to the mini-open thoracic surgery performed mainly by using some instruments to control target tissues and organs based on the vision associated with multi-limb coordination, which may be hand-assisted if necessary. The mini-invasive thoracic surgery consists of three approaches including video-assisted thoracic surgery (VATS), video-assisted Hybrid and hand-assisted VATS. So far the mini-invasive thoracic technique has achieved great advances due to the development in instruments of mini-invasive thoracic surgery which has the following features: instruments of mini-invasive thoracic surgery appear to be safe and practical, and have successive improvement and diversification in function; the specific instruments of open surgeries has been successively developed into dedicated instruments of endoscopic surgery; the application of endoscopic mechanical suture device generates faster fragmentation and reconstruction of organ tissues; the specific delicated instruments of endoscopic surgery have rapid development and application; and the simple instruments structurally similar to the conventional instruments are designed according to the mini-incison. In addition, the mini-invasive thoracic technique is widely used in five aspects including diseases of pleura membrane and chest wall, lung diseases, esophageal diseases, mediastinal diseases and heart diseases

  1. Heat and moisture exchangers and heated humidifiers in acute lung injury/acute respiratory distress syndrome patients. Effects on respiratory mechanics and gas exchange.

    PubMed

    Morán, Indalecio; Bellapart, Judith; Vari, Alessandra; Mancebo, Jordi

    2006-04-01

    To compare, in acute lung injury/acute respiratory distress syndrome (ALI/ARDS) patients, the short-term effects of heat and moisture exchangers (HME) and heated humidifiers (HH) on gas exchange, and also on respiratory system mechanics when isocapnic conditions are met. Prospective open clinical study. Intensive Care Service. Seventeen invasively ventilated ALI/ARDS patients. The study was performed in three phases: (1) determinations were made during basal ventilatory settings with HME; (2) basal ventilatory settings were maintained and HME was replaced by an HH; (3) using the same HH, tidal volume (Vt) was decreased until basal PaCO2 levels were reached. FiO2, respiratory rate and PEEP were kept unchanged. Respiratory mechanics, Vdphys, gas exchange and hemodynamic parameters were obtained at each phase. By using HH instead of HME and without changing Vt, PaCO2 decreased from 46+/-9 to 40+/-8 mmHg (p<0.001) and Vdphys decreased from 352+/-63 to 310+/-74 ml (p<0.001). Comparing the first phase with the third, Vt decreased from 521+/-106 to 440+/-118 ml (p<0.001) without significant changes in PaCO2, Vd/Vt decreased from 0.69+/-0.11 to 0.62+/-0.12 (p<0.001), plateau airway pressure decreased from 25+/-6 to 21+/-6 cmH2O (p<0.001) and respiratory system compliance improved from 35+/-12 to 42+/-15 ml/cmH2O (p<0.001). PaO2 remained unchanged in the three phases. Reducing dead space with the use of HH decreases PaCO2 and more importantly, if isocapnic conditions are maintained by reducing Vt, this strategy improves respiratory system compliance and reduces plateau airway pressure.

  2. Effect of different seated positions on lung volume and oxygenation in acute respiratory distress syndrome.

    PubMed

    Dellamonica, J; Lerolle, N; Sargentini, C; Hubert, S; Beduneau, G; Di Marco, F; Mercat, A; Diehl, J L; Richard, J C M; Bernardin, G; Brochard, L

    2013-06-01

    Lung volume available for ventilation is markedly decreased during acute respiratory distress syndrome. Body positioning may contribute to increase lung volume and partial verticalization is simple to perform. This study evaluated whether verticalization had parallel effects on oxygenation and end expiratory lung volume (EELV). Prospective multicenter study in 40 mechanically ventilated patients with ALI/ARDS in five university hospital MICUs. We evaluated four 45-min successive trunk position epochs (supine slightly elevated at 15°; semi recumbent with trunk elevated at 45°; seated with trunk elevated at 60° and legs down at 45°; back to supine). Arterial blood gases, EELV measured using the nitrogen washin/washout, and static compliance were measured. Responders were defined by a PaO₂/FiO₂ increase >20 % between supine and seated position. Results are median [25th-75th percentiles]. With median PEEP = 10 cmH₂O, verticalization increased lung volume but only responders (13 patients, 32 %) had a significant increase in EELV/PBW (predicted body weight) compared to baseline. This increase persisted at least partially when patients were positioned back to supine. Responders had a lower EELV/PBW supine [14 mL/kg (13-15) vs. 18 mL/kg (15-27) (p = 0.005)] and a lower compliance [30 mL/cmH₂O (22-38) vs. 42 (30-46) (p = 0.01)] than non-responders. Strain decreased with verticalization for responders. EELV/PBW increase and PaO₂/FiO₂ increase were not correlated. Verticalization is easily achieved and improves oxygenation in approximately 32 % of the patients together with an increase in EELV. Nonetheless, effect of verticalization on EELV/PBW is not predictable by PaO₂/FiO₂ increase, its monitoring may be helpful for strain optimization.

  3. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock, 2012.

    PubMed

    Dellinger, R P; Levy, Mitchell M; Rhodes, Andrew; Annane, Djillali; Gerlach, Herwig; Opal, Steven M; Sevransky, Jonathan E; Sprung, Charles L; Douglas, Ivor S; Jaeschke, Roman; Osborn, Tiffany M; Nunnally, Mark E; Townsend, Sean R; Reinhart, Konrad; Kleinpell, Ruth M; Angus, Derek C; Deutschman, Clifford S; Machado, Flavia R; Rubenfeld, Gordon D; Webb, Steven; Beale, Richard J; Vincent, Jean-Louis; Moreno, Rui

    2013-02-01

    positive end-expiratory pressure (PEEP) in ARDS (1B); higher rather than lower level of PEEP for patients with sepsis-induced moderate or severe ARDS (2C); recruitment maneuvers in sepsis patients with severe refractory hypoxemia due to ARDS (2C); prone positioning in sepsis-induced ARDS patients with a PaO (2)/FiO (2) ratio of ≤100 mm Hg in facilities that have experience with such practices (2C); head-of-bed elevation in mechanically ventilated patients unless contraindicated (1B); a conservative fluid strategy for patients with established ARDS who do not have evidence of tissue hypoperfusion (1C); protocols for weaning and sedation (1A); minimizing use of either intermittent bolus sedation or continuous infusion sedation targeting specific titration endpoints (1B); avoidance of neuromuscular blockers if possible in the septic patient without ARDS (1C); a short course of neuromuscular blocker (no longer than 48 h) for patients with early ARDS and a PaO (2)/FI O (2) <150 mm Hg (2C); a protocolized approach to blood glucose management commencing insulin dosing when two consecutive blood glucose levels are >180 mg/dL, targeting an upper blood glucose ≤180 mg/dL (1A); equivalency of continuous veno-venous hemofiltration or intermittent hemodialysis (2B); prophylaxis for deep vein thrombosis (1B); use of stress ulcer prophylaxis to prevent upper gastrointestinal bleeding in patients with bleeding risk factors (1B); oral or enteral (if necessary) feedings, as tolerated, rather than either complete fasting or provision of only intravenous glucose within the first 48 h after a diagnosis of severe sepsis/septic shock (2C); and addressing goals of care, including treatment plans and end-of-life planning (as appropriate) (1B), as early as feasible, but within 72 h of intensive care unit admission (2C). Recommendations specific to pediatric severe sepsis include: therapy with face mask oxygen, high flow nasal cannula oxygen, or nasopharyngeal continuous PEEP in the presence of

  4. Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2012.

    PubMed

    Dellinger, R Phillip; Levy, Mitchell M; Rhodes, Andrew; Annane, Djillali; Gerlach, Herwig; Opal, Steven M; Sevransky, Jonathan E; Sprung, Charles L; Douglas, Ivor S; Jaeschke, Roman; Osborn, Tiffany M; Nunnally, Mark E; Townsend, Sean R; Reinhart, Konrad; Kleinpell, Ruth M; Angus, Derek C; Deutschman, Clifford S; Machado, Flavia R; Rubenfeld, Gordon D; Webb, Steven A; Beale, Richard J; Vincent, Jean-Louis; Moreno, Rui

    2013-02-01

    at least a minimal amount of positive end-expiratory pressure (PEEP) in ARDS (1B); higher rather than lower level of PEEP for patients with sepsis-induced moderate or severe ARDS (2C); recruitment maneuvers in sepsis patients with severe refractory hypoxemia due to ARDS (2C); prone positioning in sepsis-induced ARDS patients with a PaO2/FIO2 ratio of ≤ 100 mm Hg in facilities that have experience with such practices (2C); head-of-bed elevation in mechanically ventilated patients unless contraindicated (1B); a conservative fluid strategy for patients with established ARDS who do not have evidence of tissue hypoperfusion (1C); protocols for weaning and sedation (1A); minimizing use of either intermittent bolus sedation or continuous infusion sedation targeting specific titration endpoints (1B); avoidance of neuromuscular blockers if possible in the septic patient without ARDS (1C); a short course of neuromuscular blocker (no longer than 48 hrs) for patients with early ARDS and a Pao2/Fio2 < 150 mm Hg (2C); a protocolized approach to blood glucose management commencing insulin dosing when two consecutive blood glucose levels are > 180 mg/dL, targeting an upper blood glucose ≤ 180 mg/dL (1A); equivalency of continuous veno-venous hemofiltration or intermittent hemodialysis (2B); prophylaxis for deep vein thrombosis (1B); use of stress ulcer prophylaxis to prevent upper gastrointestinal bleeding in patients with bleeding risk factors (1B); oral or enteral (if necessary) feedings, as tolerated, rather than either complete fasting or provision of only intravenous glucose within the first 48 hrs after a diagnosis of severe sepsis/septic shock (2C); and addressing goals of care, including treatment plans and end-of-life planning (as appropriate) (1B), as early as feasible, but within 72 hrs of intensive care unit admission (2C). Recommendations specific to pediatric severe sepsis include: therapy with face mask oxygen, high flow nasal cannula oxygen, or nasopharyngeal

  5. Performance of heated humidifiers with a heated wire according to ventilatory settings.

    PubMed

    Nishida, T; Nishimura, M; Fujino, Y; Mashimo, T

    2001-01-01

    Delivering warm, humidified gas to patients is important during mechanical ventilation. Heated humidifiers are effective and popular. The humidifying efficiency is influenced not only by performance and settings of the devices but the settings of ventilator. We compared the efficiency of humidifying devices with a heated wire and servo-controlled function under a variety of ventilator settings. A bench study was done with a TTL model lung. The study took place in the laboratory of the University Hospital, Osaka, Japan. Four devices (MR290 with MR730, MR310 with MR730; both Fisher & Paykel, ConchaTherm IV; Hudson RCI, and HummaxII; METRAN) were tested. Hummax II has been developed recently, and it consists of a heated wire and polyethylene microporous hollow fiber. Both wire and fiber were put inside of an inspiratory circuit, and water vapor is delivered throughout the circuit. The Servo 300 was connected to the TTL with a standard ventilator circuit. The ventilator settings were as follows; minute ventilation (V(E)) 5, 10, and 15 L/min, a respiratory rate of 10 breaths/min, I:E ratio 1:1, 1:2, and 1:4, and no applied PEEP. Humidifying devices were set to maintain the temperature of airway opening at 32 degrees C and 37 degrees C. The greater V(E) the lower the humidity with all devices except Hummax II. Hummax II delivered 100% relative humidity at all ventilator and humidifier settings. When airway temperature control of the devices was set at 32 degrees C, the ConchaTherm IV did not deliver 30 mg/L of vapor, which is the value recommended by American National Standards at all V(E) settings. At 10 and 15 L/min of V(E) settings MR310 with MR730 did not deliver recommended vapor, either. In conclusion, airway temperature setting of the humidifying devices influenced the humidity of inspiratory gas greatly. Ventilatory settings also influenced the humidity of inspiratory gas. The Hummax II delivered sufficient water vapor under a variety of minute ventilation.

  6. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients.

    PubMed

    Blot, Stijn I; Poelaert, Jan; Kollef, Marin

    2014-11-28

    Microaspiration of subglottic secretions through channels formed by folds in high volume-low pressure poly-vinyl chloride cuffs of endotracheal tubes is considered a significant pathogenic mechanism of ventilator-associated pneumonia (VAP). Therefore a series of prevention measures target the avoidance of microaspiration. However, although some of these can minimize microaspiration, benefits in terms of VAP prevention are not always obvious. Polyurethane-cuffed endotracheal tubes successfully reduce microaspiration but high quality data demonstrating VAP rate reduction are lacking. An analogous conclusion can be made regarding taper-shaped cuffs compared with classic barrel-shaped cuffs. More clinical data regarding these endotracheal tube designs are needed to demonstrate clinical value in addition to in vitro-based evidence. The clinical usefulness of endotracheal tubes developed for subglottic secretions drainage is established in multiple studies and confirmed by meta-analysis. Any change in cuff design will fail to prevent microaspiration if the cuff is insufficiently inflated. At least one well-designed trial demonstrated that continuous cuff pressure monitoring and control decrease the risk of VAP. Gel lubrication of the cuff prior to intubation temporarily hampers microaspiration through sludging the channels formed by folds in high volume-low pressure cuffs. As the beneficial effect of gel lubrication is temporarily, its potential to reduce VAP risk is probably nonsignificant. A minimum positive end-expiratory pressure of at least 5 cmH2O can be recommended as it reduces the risk of microaspiration in vitro and in vivo. One randomized controlled study demonstrated a reduced risk of VAP in patients ventilated with PEEP (5-8 cmH2O). Regarding head-of-bed elevation, it can be recommended to avoid supine positioning. Whether a 45° head-of-bed elevation is to be preferred above 25-30° head-of-bed elevation remains unproven. Finally, the routine monitoring of

  7. Mechanical ventilation with high tidal volume induces inflammation in patients without lung disease.

    PubMed

    Pinheiro de Oliveira, Roselaine; Hetzel, Marcio Pereira; dos Anjos Silva, Mauro; Dallegrave, Daniele; Friedman, Gilberto

    2010-01-01

    Mechanical ventilation (MV) with high tidal volumes may induce or aggravate lung injury in critical ill patients. We compared the effects of a protective versus a conventional ventilatory strategy, on systemic and lung production of tumor necrosis factor-alpha (TNF-alpha) and interleukin-8 (IL-8) in patients without lung disease. Patients without lung disease and submitted to mechanical ventilation admitted to one trauma and one general adult intensive care unit of two different university hospitals were enrolled in a prospective randomized-control study. Patients were randomized to receive MV either with tidal volume (VT) of 10 to 12 ml/kg predicted body weight (high VT group) (n = 10) or with VT of 5 to 7 ml/kg predicted body weight (low VT group) (n = 10) with an oxygen inspiratory fraction (FIO2) enough to keep arterial oxygen saturation >90% with positive end-expiratory pressure (PEEP) of 5 cmH2O during 12 hours after admission to the study. TNF-alpha and IL-8 concentrations were measured in the serum and in the bronchoalveolar lavage fluid (BALF) at admission and after 12 hours of study observation time. Twenty patients were enrolled and analyzed. At admission or after 12 hours there were no differences in serum TNF-alpha and IL-8 between the two groups. While initial analysis did not reveal significant differences, standardization against urea of logarithmic transformed data revealed that TNF-alpha and IL-8 levels in bronchoalveolar lavage (BAL) fluid were stable in the low VT group but increased in the high VT group (P = 0.04 and P = 0.03). After 12 hours, BALF TNF-alpha (P = 0.03) and BALF IL-8 concentrations (P = 0.03) were higher in the high VT group than in the low VT group. The use of lower tidal volumes may limit pulmonary inflammation in mechanically ventilated patients even without lung injury. NCT00935896.

  8. Humidification performance of two high-flow nasal cannula devices: a bench study.

    PubMed

    Chikata, Yusuke; Izawa, Masayo; Okuda, Nao; Itagaki, Taiga; Nakataki, Emiko; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2014-08-01

    Delivering heated and humidified medical gas at 20-60 L/min, high-flow nasal cannula (HFNC) creates low levels of PEEP and ameliorates respiratory mechanics. It has become a common therapy for patients with respiratory failure. However, independent measurement of heat and humidity during HFNC and comparison of HFNC devices are lacking. We evaluated 2 HFNC (Airvo 2 and Optiflow system) devices. Each HFNC was connected to simulated external nares using the manufacturer's standard circuit. The Airvo 2 outlet-chamber temperature was set at 37°C. The Optiflow system incorporated an O2/air blender and a heated humidifier, which was set at 40°C/3. For both systems, HFNC flow was tested at 20, 40, and 50 L/min. Simulating spontaneous breathing using a mechanical ventilator and TTL test lung, we tested tidal volumes (VT) of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. The TTL was connected to the simulated external nares with a standard ventilator circuit. To prevent condensation, the circuit was placed in an incubator maintained at 37°C. Small, medium, and large nasal prongs were tested. Absolute humidity (AH) of inspired gas was measured at the simulated external nares. At 20, 40, and 50 L/min of flow, respective AH values for the Airvo 2 were 35.3 ± 2.0, 37.1 ± 2.2, and 37.6 ± 2.1 mg/L, and for the Optiflow system, 33.1 ± 1.5, 35.9 ± 1.7, and 36.2 ± 1.8 mg/L. AH was lower at 20 L/min of HFNC flow than at 40 and 50 L/min (P < .01). While AH remained constant at 40 and 50 L/min, at 20 L/min of HFNC flow, AH decreased as VT increased for both devices. During bench use of HFNC, AH increased with increasing HFNC flow. When the inspiratory flow of spontaneous breathing exceeded the HFNC flow, AH was influenced by VT. At all experimental settings, AH remained > 30 mg/L.

  9. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.

    PubMed

    Uchiyama, Akinori; Yoshida, Takeshi; Yamanaka, Hidenori; Fujino, Yuji

    2013-07-01

    The resistance of the endotracheal tube (ETT), the heat and moisture exchanger (HME), and the ventilator may affect the patient's respiratory status. Although previous studies examined the inspiratory work of breathing (WOB), investigation of WOB in the expiratory phase is rare. We estimated tracheal pressure at the tip of the ETT (Ptrach) and calculated expiratory WOB imposed by the ETT, the HME, and the expiratory valve. We examined imposed expiratory WOB in patients under a continuous mandatory ventilation (CMV) mode and during spontaneous breathing trials (SBTs). We hypothesized that imposed expiratory WOB would increase with heightened ventilatory demand. We measured airway pressure (Paw) and respiratory flow (V). We estimated Ptrach using the equation Ptrach = Paw - K1 × V(K2) - 2.70 × V(L/s)(1.42). K1 and K2 were determined by the inner diameter (ID) of the ETT. Imposed expiratory WOB was calculated from the area of Ptrach above PEEP versus lung volume. We examined imposed expiratory WOB and imposed expiratory resistance in relation to mean expiratory flow. We examined 28 patients under CMV mode, and 29 during SBT. During both CMV and SBT, as mean expiratory flow increased, imposed expiratory WOB increased. The regression curves between mean expiratory flow (x) (L/s) and imposed expiratory WOB (y) (J/L) were y = 1.35x(0.83) (R(2) = 0.79) for 7 mm ID ETT under CMV, y = 1.12x(0.82) (R(2) = 0.73) for 8 mm ID ETT under CMV, y = 1.07x(1.04) (R(2) = 0.85) for 7 mm ID ETT during SBT, and y = 0.84x(0.93) (R(2) = 0.75) for 8 mm ID ETT during SBT. Levels of imposed expiratory WOB were affected by ETT diameter and ventilator mode. The reason for increasing imposed expiratory WOB was an increase in expiratory resistance imposed by the ETT and HME. Under mechanical ventilation, imposed expiratory WOB should be considered in patients with higher minute ventilation.

  10. Use of a single ventilator to support 4 patients: laboratory evaluation of a limited concept.

    PubMed

    Branson, Richard D; Blakeman, Thomas C; Robinson, Bryce Rh; Johannigman, Jay A

    2012-03-01

    A mass-casualty respiratory failure event where patients exceed available ventilators has spurred several proposed solutions. One proposal is use of a single ventilator to support 4 patients. A ventilator was modified to allow attachment of 4 circuits. Each circuit was connected to one chamber of 2 dual-chambered, test lungs. The ventilator was set at a tidal volume (V(T)) of 2.0 L, respiratory frequency of 10 breaths/min, and PEEP of 5 cm H(2)O. Tests were repeated with pressure targeted breaths at 15 cm H(2)O. Airway pressure, volume, and flow were measured at each chamber. The test lungs were set to simulate 4 patients using combinations of resistance (R) and compliance (C). These included equivalent C and R, constant R and variable C, constant C and variable R, and variable C and variable R. When R and C were equivalent the V(T) distributed to each chamber of the test lung was similar during both volume (range 428-442 mL) and pressure (range 528-544 mL) breaths. Changing C while R was constant resulted in large variations in delivered V(T) (volume range 257-621 mL, pressure range 320-762 mL). Changing R while C was constant resulted in a smaller variation in V(T) (volume range 418-460 mL, pressure range 502-554 mL) compared to only C changes. When R and C were both varied, the range of delivered V(T) in both volume (336-517 mL) and pressure (417-676 mL) breaths was greater, compared to only R changes. Using a single ventilator to support 4 patients is an attractive concept; however, the V(T) cannot be controlled for each subject and V(T) disparity is proportional to the variability in compliance. Along with other practical limitations, these findings cannot support the use of this concept for mass-casualty respiratory failure.

  11. Histologic and biochemical alterations predict pulmonary mechanical dysfunction in aging mice with chronic lung inflammation

    PubMed Central

    Laskin, Debra L.; Gow, Andrew J.

    2017-01-01

    airway opening, to a greater extent than overt acinar wall destruction. Model-predicted deficits in PEEP-dependent lung recruitment correlate with altered lung lining fluid composition independent of age or genotype. PMID:28837561

  12. Histologic and biochemical alterations predict pulmonary mechanical dysfunction in aging mice with chronic lung inflammation.

    PubMed

    Massa, Christopher B; Groves, Angela M; Jaggernauth, Smita U; Laskin, Debra L; Gow, Andrew J

    2017-08-01

    airway opening, to a greater extent than overt acinar wall destruction. Model-predicted deficits in PEEP-dependent lung recruitment correlate with altered lung lining fluid composition independent of age or genotype.

  13. Telemedicine Versus Face-to-Face Evaluations by Respiratory Therapists of Mechanically Ventilated Neonates and Children: A Pilot Study.

    PubMed

    Bell, Rebecca C; Yager, Phoebe H; Clark, Maureen E; Roumiantsev, Serguei; Venancio, Heather L; Chipman, Daniel W; Kacmarek, Robert M; Noviski, Natan N

    2016-02-01

    Mechanical ventilation is one of the most important therapeutic interventions in neonatal and pediatric ICUs. Telemedicine has been shown to reliably extend pediatric intensivist expertise to facilities where expertise is limited. If reliable, telemedicine may extend the reach of pediatric respiratory therapists (RTs) to facilities where expertise does not exist or free up existing RT resources for important face-to-face activities in facilities where expertise is limited. The aim of this study was to determine how well respiratory assessments for ventilated neonates and children correlated when performed simultaneously by 2 RTs face-to-face and via telemedicine. We conducted a pilot study including 40 assessments by 16 RTs on 11 subjects (5 neonatal ICU; 6 pediatric ICU). Anonymously completed intake forms by 2 different RTs concurrently assessing 14 ventilator-derived and patient-based respiratory variables were used to determine correlations. Forty paired assessments were performed. Median telemedicine assessment time was 8 min. The Pearson correlation coefficient (r) was used to determine agreement between continuous data, and the Cohen kappa statistics were used for binary variables. Pressure control, PEEP, breathing frequency, and FIO2 perfectly correlated (r = 1, all P < .001) as did the presence of a CO2 monitor and need for increased ventilatory support (kappa = 1). The Pearson correlation coefficient for VT, minute ventilation, mean airway pressure, and oxygen saturation ranged from 0.84 to 0.97 (all P < .001). kappa = 0.41 (95% CI 0.02-0.80) for patient-triggered breaths, and kappa = 0.57 (95% CI 0.19-0.94) for breathing frequency higher than set frequency. kappa = -0.25 (95% CI -0.46 to -0.04) for need for suctioning. Telemedicine technology was acceptable to RTs. Telemedicine evaluations highly correlated with face-to-face for 10 of 14 aspects of standard bedside respiratory assessment. Poor correlation was noted for more complex, patient

  14. Effect of assist negative pressure ventilation by microprocessor based iron lung on breathing effort

    PubMed Central

    Gorini, M; Villella, G; Ginanni, R; Augustynen, A; Tozzi, D; Corrado, A

    2002-01-01

    Background: The lack of patient triggering capability during negative pressure ventilation (NPV) may contribute to poor patient synchrony and induction of upper airway collapse. This study was undertaken to evaluate the performance of a microprocessor based iron lung capable of thermistor triggering. Methods: The effects of NPV with thermistor triggering were studied in four normal subjects and six patients with an acute exacerbation of chronic obstructive pulmonary disease (COPD) by measuring: (1) the time delay (TDtr) between the onset of inspiratory airflow and the start of assisted breathing; (2) the pressure-time product of the diaphragm (PTPdi); and (3) non-triggering inspiratory efforts (NonTrEf). In patients the effects of negative extrathoracic end expiratory pressure (NEEP) added to NPV were also evaluated. Results: With increasing trigger sensitivity the mean (SE) TDtr ranged from 0.29 (0.02) s to 0.21 (0.01) s (mean difference 0.08 s, 95% CI 0.05 to 0.12) in normal subjects and from 0.30 (0.02) s to 0.21 (0.01) s (mean difference 0.09 s, 95% CI 0.06 to 0.12) in patients with COPD; NonTrEf ranged from 8.2 (1.8)% to 1.2 (0.1)% of the total breaths in normal subjects and from 11.8 (2.2)% to 2.5 (0.4)% in patients with COPD. Compared with spontaneous breathing, PTPdi decreased significantly with NPV both in normal subjects and in patients with COPD. NEEP added to NPV resulted in a significant decrease in dynamic intrinsic PEEP, diaphragm effort exerted in the pre-trigger phase, and NonTrEf. Conclusions: Microprocessor based iron lung capable of thermistor triggering was able to perform assist NPV with acceptable TDtr, significant unloading of the diaphragm, and a low rate of NonTrEf. NEEP added to NPV improved the synchrony between the patient and the ventilator. PMID:11867832

  15. Efficacy of continuous positive airway pressure and incentive spirometry on respiratory functions during the postoperative period following supratentorial craniotomy: A prospective randomized controlled study.

    PubMed

    Sah, Hulya Kahraman; Akcil, Eren Fatma; Tunali, Yusuf; Vehid, Hayriye; Dilmen, Ozlem Korkmaz

    2017-11-01

    Volume controlled ventilation with low PEEP is used in neuro-anesthesia to provide constant PaCO 2 levels and prevent raised intracranial pressure. Therefore, neurosurgery patients prone to atelectasis formation, however, we could not find any study that evaluates prevention of postoperative pulmonary complications in neurosurgery. A prospective, randomized controlled study. Intensive care unit in a university hospital in Istanbul. Seventy-nine ASAI-II patients aged between 18 and 70years scheduled for elective supratentorial craniotomy were included in the study. Patients randomized into 3 groups after surgery. The Group IS (n=20) was treated with incentive spirometry 5 times in 1min and 5min per hour, the Group CPAP (n=20) with continuous positive airway pressure 10 cmH 2 O pressure and 0.4 F i O 2 via an oronasal mask 5min per hour, and the Group Control (n=20) 4L·min -1 O 2 via mask; all during the first 6h postoperatively. Respiratory functions tests and arterial blood gases analysis were performed before the induction of anesthesia (Baseline), 30min, 6h, 24h postoperatively. The IS and CPAP applications have similar effects with respect to FVC values. The postoperative 30min FEV 1 values were statistically significantly reduced compared to the Baseline in all groups (p<0.0001). FEV 1 values were statistically significantly increased at the postoperative 24h compared to the postoperative 30min in the Groups IS and CPAP (p<0.0001). This increase, however, was not observed in the Group Control, and the postoperative 24h FEV 1 values were statistically significantly lower in the Group Control compared to the Group IS (p=0.015). Although this study is underpowered to detect differences in FEV 1 values, the postoperative 24h FEV 1 values were significantly higher in the IS group than the Control group and this difference was not observed between the CPAP and Control groups. It might be evaluate a favorable effect of IS in neurosurgery patients. But larger studies

  16. The association between physiologic dead-space fraction and mortality in subjects with ARDS enrolled in a prospective multi-center clinical trial.

    PubMed

    Kallet, Richard H; Zhuo, Hanjing; Liu, Kathleen D; Calfee, Carolyn S; Matthay, Michael A

    2014-11-01

    We tested the association between pulmonary dead-space fraction (ratio of dead space to tidal volume [V(D)/V(T)]) and mortality in subjects with ARDS (Berlin definition, P(aO2)/F(IO2) ≤ 300 mm Hg; PEEP ≥ 5 cm H2O) enrolled into a clinical trial incorporating lung-protective ventilation. We conducted a prospective, multi-center study at medical-surgical ICUs in the United States. A total of 126 ALI subjects with acute lung injury were enrolled into a phase 3 randomized, placebo-controlled study of aerosolized albuterol. V(D)/V(T) and pulmonary mechanics were measured within 4 h of enrollment and repeated daily on study days 1 and 2 in subjects requiring arterial blood gases for clinical management. At baseline, non-survivors had a trend toward higher V(D)/V(T) compared with survivors (0.62 ± 0.11 vs 0.56 ± 0.11, respectively, P = .08). Differences in V(D)/V(T) between non-survivors and survivors became significant on study days 1 (0.64 ± 0.12 vs 0.55 ± 0.11, respectively, P = .01) and 2 (0.67 ± 0.12 vs 0.56 ± 0.11, respectively, P = .004). Likewise, the association between VD/VT and mortality was significant on study day 1 (odds ratio per 0.10 change in V(D)/V(T) [95% CI]: 6.84 [1.62-28.84] P = .01; and study day 2: 4.90 [1.28-18.73] P = .02) after adjusting for V(D)/V(T), P(aO2)/F(IO2), oxygenation index, vasopressor use, and the primary risk for ARDS. Using a Cox proportional hazard model, V(D)/V(T) was associated with a trend toward higher mortality (HR = 4.37 [CI 0.99-19.32], P = .052) that became significant when the analysis was adjusted for daily oxygenation index (HR = 1.74 [95% CI 1.12-3.35] P = .04). Markedly elevated V(D)/V(T) (≥ 0.60) in early ARDS is associated with higher mortality. Measuring V(D)/V(T) may be useful in identifying ARDS patients at increased risk of death who are enrolled into a therapeutic trial. Copyright © 2014 by Daedalus Enterprises.

  17. A bench evaluation of fraction of oxygen in air delivery and tidal volume accuracy in home care ventilators available for hospital use

    PubMed Central

    Baboi, Loredana; Subtil, Fabien

    2016-01-01

    Background Turbine-powered ventilators are not only designed for long-term ventilation at home but also for hospital use. It is important to verify their capabilities in delivering fraction of oxygen in air (FIO2) and tidal volume (VT). Methods We assessed the FIO2 accuracy and the VT delivery in four home care ventilators (HCV) on the bench. The four HCV were Astral 150, Elisée 150, Monnal T50 and Trilogy 200 HCV, which were connected to a lung model (ASL 5000). For assessing FIO2 accuracy, lung model was set to mimic an obstructive lung and HCV were set in volume controlled mode (VC). They supplied with air, 3 or 15 L/min oxygen and FIO2 was measured by using a ventilator tester (Citrex H4TM). For the VT accuracy, the lung model was set in a way to mimic three adult configurations (normal, obstructive, or restrictive respiratory disorder) and one pediatric configuration. Each HCV was set in VC. Two VT (300 and 500 mL) in adult lung configuration and one 50 mL VT in pediatric lung configuration, at two positive end expiratory pressures 5 and 10 cmH2O, were tested. VT accuracy was measured as volume error (the relative difference between set and measured VT). Statistical analysis was performed by suing one-factor ANOVA with a Bonferroni correction for multiple tests. Results For Astral 150, Elisée 150, Monnal T50 and Trilogy 200, FIO2 averaged 99.2%, 93.7%, 86.3%, and 62.1%, respectively, at 15 L/min oxygen supplementation rate (P<0.001). Volume error was 0.5%±0%, −38%±0%, −9%±0%, −29%±0% and −36%±0% for pediatric lung condition (P<0.001). In adult lung configurations, Monnal T50 systematically over delivered VT and Trilogy 150 was sensitive to lung configuration when VT was set to 300 mL at either positive end-expiratory pressure (PEEP). Conclusions HCV are different in terms of FIO2 efficiency and VT delivery. PMID:28149559

  18. Practice of mechanical ventilation in cardiac arrest patients and effects of targeted temperature management: A substudy of the targeted temperature management trial.

    PubMed

    Harmon, Matthew B A; van Meenen, David M P; van der Veen, Annelou L I P; Binnekade, Jan M; Dankiewicz, Josef; Ebner, Florian; Nielsen, Niklas; Pelosi, Paolo; Schultz, Marcus J; Horn, Janneke; Friberg, Hans; Juffermans, Nicole P

    2018-05-12

    Mechanical ventilation practices in patients with cardiac arrest are not well described. Also, the effect of temperature on mechanical ventilation settings is not known. The aims of this study were 1) to describe practice of mechanical ventilation and its relation with outcome 2) to determine effects of different target temperatures strategies (33 °C versus 36 °C) on mechanical ventilation settings. This is a substudy of the TTM-trial in which unconscious survivors of a cardiac arrest due to a cardiac cause were randomized to two TTM strategies, 33 °C (TTM33) and 36 °C (TTM36). Mechanical ventilation data were obtained at three time points: 1) before TTM; 2) at the end of TTM (before rewarming) and 3) after rewarming. Logistic regression was used to determine an association between mechanical ventilation variables and outcome. Repeated-measures mixed modelling was performed to determine the effect of TTM on ventilation settings. Mechanical ventilation data was available for 567 of the 950 TTM patients. Of these, 81% was male with a mean (SD) age of 64 (12) years. At the end of TTM median tidal volume was 7.7 ml/kg predicted body weight (PBW)(6.4-8.7) and 60% of patients were ventilated with a tidal volume ≤ 8 ml/kg PBW. Median PEEP was 7.7cmH 2 O (6.4-8.7) and mean driving pressure was 14.6 cmH 2 O (±4.3). The median FiO 2 fraction was 0.35 (0.30-0.45). Multivariate analysis showed an independent relationship between increased respiratory rate and 28-day mortality. TTM33 resulted in lower end-tidal CO 2 (Pgroup = 0.0003) and higher alveolar dead space fraction (Pgroup = 0.003) compared to TTM36, while PCO 2 levels and respiratory minute volume were similar between groups. In the majority of the cardiac arrest patients, protective ventilation settings are applied, including low tidal volumes and driving pressures. High respiratory rate was associated with mortality. TTM33 results in lower end-tidal CO 2 levels and a higher alveolar dead

  19. Regional physiology of ARDS.

    PubMed

    Gattinoni, Luciano; Tonetti, Tommaso; Quintel, Michael

    2017-12-28

    positive end-expiratory pressure (PEEP). In the end, decreasing mechanical power, increasing lung homogeneity, and avoiding reaching the anatomical limits of the 'baby lung' should be the goals for safe ventilation in ARDS.

  20. Effects of methacholine infusion on desflurane pharmacokinetics in piglets☆

    PubMed Central

    Kozian, Alf; Kretzschmar, Moritz; Baumgardner, James E.; Schreiber, Jens; Hedenstierna, Göran; Larsson, Anders; Hachenberg, Thomas; Schilling, Thomas

    2015-01-01

    The data of a corresponding animal experiment demonstrates that nebulized methacholine (MCh) induced severe bronchoconstriction and significant inhomogeneous ventilation and pulmonary perfusion (V̇A/Q̇) distribution in pigs, which is similar to findings in human asthma. The inhalation of MCh induced bronchoconstriction and delayed both uptake and elimination of desflurane (Kretzschmar et al., 2015) [1]. The objective of the present data is to determine V̇A/Q̇ matching by Multiple Inert Gas Elimination Technique (MIGET) in piglets before and during methacholine- (MCh-) induced bronchoconstriction, induced by MCh infusion, and to assess the blood concentration profiles for desflurane (DES) by Micropore Membrane Inlet Mass Spectrometry (MMIMS). Healthy piglets (n=4) under general anesthesia were instrumented with arterial, central venous, and pulmonary artery lines. The airway was secured via median tracheostomy with an endotracheal tube, and animals were mechanically ventilated with intermittent positive pressure ventilation (IPPV) with a FiO2 of 0.4, tidal volume (VT)=10 ml/kg and PEEP of 5cmH2O using an open system. The determination of V.A/Q. was done by MIGET: before desflurane application and at plateau in both healthy state and during MCh infusion. Arterial blood was sampled at 0, 1, 2, 5, 10, 20, and 30 min during wash-in and washout, respectively. Bronchoconstriction was established by MCH infusion aiming at doubling the peak airway pressure, after which wash-in and washout of the anesthetic gas was repeated. Anesthesia gas concentrations were measured by MMIMS. Data were analyzed by ANOVA, paired t-test, and by nonparametric Friedman׳s test and Wilcoxon׳s matched pairs test. We measured airway pressures, pulmonary resistance, and mean paO2 as well as hemodynamic variables in all pigs before desflurane application and at plateau in both healthy state and during methacholine administration by infusion. By MIGET, fractional alveolar ventilation and

  1. Perceptions of diagnosis and management of patients with acute respiratory distress syndrome: a survey of United Kingdom intensive care physicians.

    PubMed

    Dushianthan, Ahilanandan; Cusack, Rebecca; Chee, Nigel; Dunn, John-Oliver; Grocott, Michael P W

    2014-01-01

    Acute respiratory distress syndrome (ARDS) is a potentially devastating refractory hypoxemic illness with multi-organ involvement. Although several randomised controlled trials into ventilator and fluid management strategies have provided level 1 evidence to guide supportive therapy, there are few, established guidelines on how to manage patients with ARDS. In addition, and despite their continued use, pharmacotherapies for ARDS disease modulation have no proven benefit in improving mortality. Little is known however about the variability in diagnostic and treatment practices across the United Kingdom (UK). The aim of this survey, therefore, was to assess the use of diagnostic criteria and treatment strategies for ARDS in critical care units across the UK. The survey questionnaire was developed and internally piloted at University Hospital Southampton NHS Foundation Trust. Following ethical approval from University of Southampton Ethics and Research Committee, a link to an online survey engine (Survey Monkey) was then placed on the Intensive Care Society (UK) website. Fellows of The Intensive Care Society were subsequently personally approached via e-mail to encourage participation. The survey was conducted over a period of 3 months. The survey received 191 responses from 125 critical care units, accounting for 11% of all registered intensive care physicians at The Intensive Care Society. The majority of the responses were from physicians managing general intensive care units (82%) and 34% of respondents preferred the American European Consensus Criteria for ARDS. There was a perceived decline in both incidence and mortality in ARDS. Primary ventilation strategies were based on ARDSnet protocols, though frequent deviations from ARDSnet positive end expiratory pressure (PEEP) recommendations (51%) were described. The majority of respondents set permissive blood gas targets (hypoxia (92%), hypercapnia (58%) and pH (90%)). The routine use of pharmacological agents is

  2. Effects of lung protective mechanical ventilation associated with permissive respiratory acidosis on regional extra-pulmonary blood flow in experimental ARDS.

    PubMed

    Hering, Rudolf; Kreyer, Stefan; Putensen, Christian

    2017-10-27

    Lung protective mechanical ventilation with limited peak inspiratory pressure has been shown to affect cardiac output in patients with ARDS. However, little is known about the impact of lung protective mechanical ventilation on regional perfusion, especially when associated with moderate permissive respiratory acidosis. We hypothesized that lung protective mechanical ventilation with limited peak inspiratory pressure and moderate respiratory acidosis results in an increased cardiac output but unequal distribution of blood flow to the different organs of pigs with oleic-acid induced ARDS. Twelve pigs were enrolled, 3 died during instrumentation and induction of lung injury. Thus, 9 animals received pressure controlled mechanical ventilation with a PEEP of 5 cmH 2 O and limited peak inspiratory pressure (17 ± 4 cmH 2 O) versus increased peak inspiratory pressure (23 ± 6 cmH 2 O) in a crossover-randomized design and were analyzed. The sequence of limited versus increased peak inspiratory pressure was randomized using sealed envelopes. Systemic and regional hemodynamics were determined by double indicator dilution technique and colored microspheres, respectively. The paired student t-test and the Wilcoxon test were used to compare normally and not normally distributed data, respectively. Mechanical ventilation with limited inspiratory pressure resulted in moderate hypercapnia and respiratory acidosis (PaCO 2 71 ± 12 vs. 46 ± 9 mmHg, and pH 7.27 ± 0.05 vs. 7.38 ± 0.04, p < 0.001, respectively), increased cardiac output (140 ± 32 vs. 110 ± 22 ml/min/kg, p<0.05) and regional blood flow in the myocardium, brain and spinal cord, adrenal and thyroid glands, the mucosal layers of the esophagus and jejunum, the muscularis layers of the esophagus and duodenum, and the gall and urinary bladders. Perfusion of kidneys, pancreas, spleen, hepatic arterial bed, and the mucosal and muscularis blood flow to the other evaluated intestinal regions remained unchanged. In this

  3. A dual closed-loop control system for mechanical ventilation.

    PubMed

    Tehrani, Fleur; Rogers, Mark; Lo, Takkin; Malinowski, Thomas; Afuwape, Samuel; Lum, Michael; Grundl, Brett; Terry, Michael

    2004-04-01

    Closed-loop mechanical ventilation has the potential to provide more effective ventilatory support to patients with less complexity than conventional ventilation. The purpose of this study was to investigate the effectiveness of an automatic technique for mechanical ventilation. Two closed-loop control systems for mechanical ventilation are combined in this study. In one of the control systems several physiological data are used to automatically adjust the frequency and tidal volume of breaths of a patient. This method, which is patented under US Patent number 4986268, uses the criterion of minimal respiratory work rate to provide the patient with a natural pattern of breathing. The inputs to the system include data representing CO2 and O2 levels of the patient as well as respiratory compliance and airway resistance. The I:E ratio is adjusted on the basis of the respiratory time constant to allow for effective emptying of the lungs in expiration and to avoid intrinsic positive end expiratory pressure (PEEP). This system is combined with another closed-loop control system for automatic adjustment of the inspired fraction of oxygen of the patient. This controller uses the feedback of arterial oxygen saturation of the patient and combines a rapid stepwise control procedure with a proportional-integral-derivative (PID) control algorithm to automatically adjust the oxygen concentration in the patient's inspired gas. The dual closed-loop control system has been examined by using mechanical lung studies, computer simulations and animal experiments. In the mechanical lung studies, the ventilation controller adjusted the breathing frequency and tidal volume in a clinically appropriate manner in response to changes in respiratory mechanics. The results of computer simulations and animal studies under induced disturbances showed that blood gases were returned to the normal physiologic range in less than 25 s by the control system. In the animal experiments understeady

  4. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion.

    PubMed

    Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Pelosi, Paolo; Silva, Pedro L; de Abreu, Marcelo Gama; Rocco, Patricia R M

    2017-01-01

    Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV ( n = 6/group) [tidal volume (V T ) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH 2 O, fraction of inspired oxygen (FiO 2 ) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated V T values ( n = 1200; mean V T = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH 2 0/ml and 2.0 ± 0.8 cmH 2 0/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9-33.1] and VV 5.4% [3.1-8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and

  5. Subject-specific cardiovascular system model-based identification and diagnosis of septic shock with a minimally invasive data set: animal experiments and proof of concept.

    PubMed

    Chase, J Geoffrey; Lambermont, Bernard; Starfinger, Christina; Hann, Christopher E; Shaw, Geoffrey M; Ghuysen, Alexandre; Kolh, Philippe; Dauby, Pierre C; Desaive, Thomas

    2011-01-01

    A cardiovascular system (CVS) model and parameter identification method have previously been validated for identifying different cardiac and circulatory dysfunctions in simulation and using porcine models of pulmonary embolism, hypovolemia with PEEP titrations and induced endotoxic shock. However, these studies required both left and right heart catheters to collect the data required for subject-specific monitoring and diagnosis-a maximally invasive data set in a critical care setting although it does occur in practice. Hence, use of this model-based diagnostic would require significant additional invasive sensors for some subjects, which is unacceptable in some, if not all, cases. The main goal of this study is to prove the concept of using only measurements from one side of the heart (right) in a 'minimal' data set to identify an effective patient-specific model that can capture key clinical trends in endotoxic shock. This research extends existing methods to a reduced and minimal data set requiring only a single catheter and reducing the risk of infection and other complications-a very common, typical situation in critical care patients, particularly after cardiac surgery. The extended methods and assumptions that found it are developed and presented in a case study for the patient-specific parameter identification of pig-specific parameters in an animal model of induced endotoxic shock. This case study is used to define the impact of this minimal data set on the quality and accuracy of the model application for monitoring, detecting and diagnosing septic shock. Six anesthetized healthy pigs weighing 20-30 kg received a 0.5 mg kg(-1) endotoxin infusion over a period of 30 min from T0 to T30. For this research, only right heart measurements were obtained. Errors for the identified model are within 8% when the model is identified from data, re-simulated and then compared to the experimentally measured data, including measurements not used in the identification

  6. Methods of in-vivo mouse lung micro-CT

    NASA Astrophysics Data System (ADS)

    Recheis, Wolfgang A.; Nixon, Earl; Thiesse, Jacqueline; McLennan, Geoffrey; Ross, Alan; Hoffman, Eric

    2005-04-01

    Micro-CT will have a profound influence on the accumulation of anatomical and physiological phenotypic changes in natural and transgenetic mouse models. Longitudinal studies will be greatly facilitated, allowing for a more complete and accurate description of events if in-vivo studies are accomplished. The purpose of the ongoing project is to establish a feasible and reproducible setup for in-vivo mouse lung micro-computed tomography (μCT). We seek to use in-vivo respiratory-gated μCT to follow mouse models of lung disease with subsequent recovery of the mouse. Methodologies for optimizing scanning parameters and gating for the in-vivo mouse lung are presented. A Scireq flexiVent ventilated the gas-anesthetized mice at 60 breaths/minute, 30 cm H20 PEEP, 30 ml/kg tidal volume and provided a respiratory signal to gate a Skyscan 1076 μCT. Physiologic monitoring allowed the control of vital functions and quality of anesthesia, e.g. via ECG monitoring. In contrary to longer exposure times with ex-vivo scans, scan times for in-vivo were reduced using 35μm pixel size, 158ms exposure time and 18μm pixel size, 316ms exposure time to reduce motion artifacts. Gating via spontaneous breathing was also tested. Optimal contrast resolution was achieved at 50kVp, 200μA, applying an aluminum filter (0.5mm). There were minimal non-cardiac related motion artifacts. Both 35μm and 1μm voxel size images were suitable for evaluation of the airway lumen and parenchymal density. Total scan times were 30 and 65 minutes respectively. The mice recovered following scanning protocols. In-vivo lung scanning with recovery of the mouse delivered reasonable image quality for longitudinal studies, e.g. mouse asthma models. After examining 10 mice, we conclude μCT is a feasible tool evaluating mouse models of lung pathology in longitudinal studies with increasing anatomic detail available for evaluation as one moves from in-vivo to ex-vivo studies. Further developments include automated

  7. Bipolar sealing of lung parenchyma: tests in an ex vivo model.

    PubMed

    Kirschbaum, A; Clemens, A; Steinfeldt, T; Pehl, A; Meyer, C; Bartsch, D K

    2015-01-01

    Almost every pulmonary lobe resection requires cutting the lung parenchyma in the area of a lung fissure. A monopolar cutter or stapler is often used for this purpose. The seal should be absolutely airtight to prevent post-operative pulmonary fistulas. In the present study, the bipolar sealing technique was evaluated regarding air tightness of the seals during normal ventilation and its burst pressure in an ex vivo animal model. The investigations were carried out on paracardial lung lobes obtained from heart-lung preparations taken from freshly killed pigs at a slaughter house. In the laboratory, each individual lobe was perfused with Ringer's solution at body temperature and protectively ventilated through a tube (frequency: 20 1/min, p insp = 20 mbar, PEEP +5 mbar). Non-anatomic resection was carried out in the periphery of the lung lobe. The two control groups (12 lobes per group; Group 1-stapler, Group 2-parenchyma suture) were compared to three groups in which different bipolar sealing instruments were used. They were Group 3-MARSEAL(®) 10 mm (KLS Martin, Tuttlingen); Group 4-MARSEAL(®) 5 mm; and Group 5-MARCLAMP(®) (KLS Martin, Tuttlingen). The SealSafe(®) G3 electric current was used in all cases. Ventilation was continued for 20 min following parenchymal resection. Parenchymal sealing was then judged visually in a water bath and given a score (0-3). Burst pressure (mbar) was measured by increasing the inspiration pressure stepwise. Group mean values were compared (nonparametric Mann-Whitney U test, p < 0.005). Parenchymal seals were airtight under ventilation throughout the observation period in all groups. Mean burst pressures were as follows: Group 1: 47.1 ± 6.2 mbar; Group 2: 32.9 ± 3.9 mbar; Group 3: 38.8 ± 2.2 mbar; Group 4: 25.0 ± 6.4 mbar; and Group 5: 32.9 ± 5.8 mbar. Group 1, the stapler group, thus exhibited the highest burst pressures. Burst pressures for Group 3 were significantly greater than those for Group 2 (p < 0.006). Burst

  8. Can fiberoptic bronchoscopy be applied to critically ill patients treated with noninvasive ventilation for acute respiratory distress syndrome? Prospective observational study.

    PubMed

    Korkmaz Ekren, Pervin; Basarik Aydogan, Burcu; Gurgun, Alev; Tasbakan, Mehmet Sezai; Bacakoglu, Feza; Nava, Stefano

    2016-05-31

    Noninvasive ventilation (NIV) is a cornerstone for the treatment of acute respiratory failure of various etiologies. Using NIV is discussed in mild-to-moderate acute respiratory distress syndrome (ARDS) patients (PaO2/FiO2 > 150). These patients often have comorbidities that increase the risk for bronchoscopy related complications. The primary outcome of this prospective observational study was to evaluate the feasibility, safety and contribution in diagnosis and/or modification of the ongoing treatment of fiberoptic bronchoscopy (FOB) in patients with ARDS treated with NIV. ARDS patients treated with NIV and who require FOB as the diagnostic or therapeutic procedure were included the study. Intensive care ventilators or other dedicated NIV ventilators were used. NIV was applied via simple oro-nasal mask or full-face mask. Pressure support or inspiratory positive airway pressure (IPAP), external positive end expiratory pressure (PEEP) or expiratory positive airway pressure (EPAP) levels were titrated to achieve an expiratory tidal volume of 8 to 10 ml/kg according to ideal body weight, SpO2 > 90 % and respiratory rate below 25/min. Twenty eight subjects (mean age 63.3 ± 15.9 years, 15 men, 13 women, PaO2/FiO2 rate 145 ± 50.1 at admission) were included the study. Overall the procedure was well tolerated with only 5 (17.9 %) patients showing minor complications. There was no impairment in arterial blood gas and cardiopulmonary parameters after FOB. PaO2/FiO2 rate increased from 132.2 ± 49.8 to 172.9 ± 63.2 (p = 0.001). No patient was intubated within 2 h after the bronchoscopy. 10.7, 32.1 and 39.3 % of the patients required invasive mechanical ventilation after 8 h, 24 h and 48 h, respectively. Bronchoscopy provided diagnosis in 27 (96.4 %) patients. Appropriate treatment was decided according to the results of the bronchoscopic sampling in 20 (71.4 %) patients. FOB under NIV could be considered as a feasible tool for

  9. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion

    PubMed Central

    Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S.; Santos, Cintia L.; Huhle, Robert; Capelozzi, Vera L.; Pelosi, Paolo; Silva, Pedro L.; de Abreu, Marcelo Gama; Rocco, Patricia R. M.

    2017-01-01

    Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group) [tidal volume (VT) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH2O, fraction of inspired oxygen (FiO2) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular

  10. Nasal high-flow oxygen therapy in patients with hypoxic respiratory failure: effect on functional and subjective respiratory parameters compared to conventional oxygen therapy and non-invasive ventilation (NIV).

    PubMed

    Schwabbauer, Norbert; Berg, Björn; Blumenstock, Gunnar; Haap, Michael; Hetzel, Jürgen; Riessen, Reimer

    2014-01-01

    Aim of the study was to compare the short-term effects of oxygen therapy via a high-flow nasal cannula (HFNC) on functional and subjective respiratory parameters in patients with acute hypoxic respiratory failure in comparison to non-invasive ventilation (NIV) and standard treatment via a Venturi mask. Fourteen patients with acute hypoxic respiratory failure were treated with HFNC (FiO2 0.6, gas flow 55 l/min), NIV (FiO2 0.6, PEEP 5 cm H2O Hg, tidal volume 6-8 ml/kg ideal body weight,) and Venturi mask (FiO2 0.6, oxygen flow 15 l/min,) in a randomized order for 30 min each. Data collection included objective respiratory and circulatory parameters as well as a subjective rating of dyspnea and discomfort by the patients on a 10-point scale. In a final interview, all three methods were comparatively evaluated by each patient using a scale from 1 (=very good) to 6 (=failed) and the patients were asked to choose one method for further treatment. PaO2 was highest under NIV (129 ± 38 mmHg) compared to HFNC (101 ± 34 mmHg, p <0.01 vs. NIV) and VM (85 ± 21 mmHg, p <0.001 vs. NIV, p <0.01 vs. HFNC, ANOVA). All other functional parameters showed no relevant differences. In contrast, dyspnea was significantly better using a HFNC (2.9 ± 2.1, 10-point Borg scale) compared to NIV (5.0 ± 3.3, p <0.05), whereas dyspnea rating under HFNC and VM (3.3 ± 2.3) was not significantly different. A similar pattern was found when patients rated their overall discomfort on the 10 point scale: HFNC 2.7 ± 1.8, VM 3.1 ± 2.8 (ns vs. HFNC), NIV 5.4 ± 3.1 (p <0.05 vs. HFNC). In the final evaluation patients gave the best ratings to HFNC 2.3 ± 1.4, followed by VM 3.2 ± 1.7 (ns vs. HFNC) and NIV 4.5 ± 1.7 (p <0.01 vs. HFNC and p <0.05 vs. VM). For further treatment 10 patients chose HFNC, three VM and one NIV. In hypoxic respiratory failure HFNC offers a good balance between oxygenation and comfort compared to NIV and Venturi mask and seems to be well tolerated by patients. GERMAN

  11. The effect of changing the sequence of cuff inflation and device fixation with the LMA-Supreme® on device position, ventilatory complications, and airway morbidity: a clinical and fiberscopic study.

    PubMed

    Bergmann, Ingo; Crozier, Thomas Allen; Roessler, Markus; Schotola, Hanna; Mansur, Ashham; Büttner, Benedikt; Hinz, José Maria; Bauer, Martin

    2014-01-04

    The conventional sequence when using supraglottic airway devices is insertion, cuff inflation and fixation. Our hypothesis was that a tighter fit of the cuff and tip could be achieved with a consequently lower incidence of air leak, better separation of gastrointestinal and respiratory tracts and less airway morbidity if the device were first affixed and the cuff then inflated. Our clinical review board approved the study (public registry number DRKS00003174). An LMA Supreme® was inserted into 184 patients undergoing lower limb arthroscopy in propofol-remifentanil anaesthesia who were randomly assigned to either the control (inflation then fixation; n = 92) or study group (fixation then inflation; n = 92). The cuff was inflated to 60 cmH2O. The patients' lungs were ventilated in pressure-controlled mode with 5 cmH2O PEEP, Pmax to give 6 ml kg-1 tidal volume, and respiratory rate adjusted to end-tidal CO2 of 4.8 and 5.6 kPa. Correct cuff and tip position were determined by leak detection, capnometry trace, oropharyngeal leak pressure, suprasternal notch test, and lube-tube test. Bowl and cuff position and the presence of glottic narrowing were assessed by fiberscopic examination. Postoperative dysphagia, hoarseness and sore throat were assessed with a questionnaire. Ventilatory impairment was defined as a tidal volume < 6 ml kg-1 with Pmax at oropharyngeal leak pressure, glottic narrowing was defined as an angle between the vocal cords under 16 degrees. The incidence of incorrect device position (18% vs. 21%), failed ventilation (10% vs. 9%), leak pressure (24.8 vs. 25.2 cmH2O, p = 0.63), failed lube-tube test (16.3% vs. 17.6%) and glottic narrowing (19.3% vs. 14.1%, p = 0.35) was similar in both groups (control vs. study, resp.). When glottic narrowing occurred, it was more frequently associated with ventilatory impairment in the control group (77% vs. 39%; p = 0.04). Airway morbidity was more common in the control group (33% vs. 19

  12. Predicting Survival After Extracorporeal Membrane Oxygenation for ARDS: An External Validation of RESP and PRESERVE Scores.

    PubMed

    Brunet, Jennifer; Valette, Xavier; Buklas, Dimitrios; Lehoux, Philippe; Verrier, Pierre; Sauneuf, Bertrand; Ivascau, Calin; Dalibert, Yves; Seguin, Amélie; Terzi, Nicolas; Babatasi, Gérard; du Cheyron, Damien; Parienti, Jean-Jacques; Daubin, Cédric

    2017-07-01

    We aimed to test the performance of PRESERVE and RESP scores to predict death in patients with severe ARDS receiving extracorporeal membrane oxygenation (ECMO) with different case mixes. All consecutive patients treated with ECMO for refractory ARDS, regardless of cause, in the Caen University Hospital in northwestern France over the last decade were included in a retrospective cohort study. The receiver operating characteristic curves of each score were plotted, and the area under the curve was computed to assess their performance in predicting mortality (c-index). Forty-one subjects were included. Pre-ECMO ventilator settings were: mean V T , 6.1 ± 0.9 mL/kg; breathing frequency, 32 ± 4 breaths/min; PEEP, 11 ± 4 cm H 2 O; peak inspiratory pressure, 48 ± 9 cm H 2 O; plateau pressure, 30.4 ± 4.4 cm H 2 O. At ECMO initiation, blood gas results were: pH 7.22 ± 0.17, P aO 2 /F IO 2 = 63 ± 22 mm Hg; P aCO 2 = 56 ± 18 mm Hg; F IO 2 = 99 ± 2%. Pre-ECMO data were available in 35 and 27 subjects for calculation of the PRESERVE score and RESP score, respectively. Pre-ECMO scoring system results were: median PRESERVE score, 4 (interquartile range 2-5), and median RESP score, 0 (interquartile range -2 to 2). Twenty-three subjects (56%) died, including 19 receiving ECMO. In univariate analysis, plateau pressure ( P = .031), driving pressure ( P = <.001), and compliance ( P = .02) recorded at the time of ECMO initiation as well as the PRESERVE score ( P = .032) were significantly associated with mortality. With a c-index of 0.69 (95% CI 0.53-0.87), the PRESERVE score had better discrimination than the RESP score (c-index of 0.60 [95% CI 0.41-0.78]) for predicting mortality. The use of these scores in helping physicians to determine the patients with ARDS most likely to benefit from ECMO should be limited in clinical practice because of their relatively poor performance in predicting death in subjects with severe ARDS receiving ECMO support. Before widespread use is

  13. Neutrophil oxidative burst activation and the pattern of respiratory physiologic abnormalities in the fulminant post-traumatic adult respiratory distress syndrome.

    PubMed

    Rivkind, A I; Siegel, J H; Littleton, M; De Gaetano, A; Mamantov, T; Laghi, F; Stoklosa, J C

    1991-01-01

    The role of neutrophil oxidative burst activation (OBA) in the development of fulminant post-trauma adult respiratory distress syndrome (ARDS) was studied in 30 patients. Neutrophil (PMN) chemiluminescence (LE) was used as the index of OBA. Serially, for 8 days post-trauma, patient neutrophils (Pc) were studied in their own serum (Ps) normal serum (Ns), or Gey's solution (G). Ps was checked against normal neutrophils (Nc) for inhibition. LE was initiated by the addition of preopsonized zymosan to 1 x 10(6) PMN, the LE response monitored by luminometer, and the peak of the integral of LE recorded. Seven developed ARDS within the first 4 days; 12 patients developed sepsis (TS) but no ARDS, and 11 patients had uncomplicated trauma (TR). All ARDS showed increased LE (P less than 0.0001), at 48-96 hr. Patients without ARDS showed no significant increase in LE, although their mean injury severity (ISS) was the same. The ARDS LE response was mediated by activation of Pc [74%] with only a small but significant additional effect (6%) by ARDS serum (Ps): LE = 0.672 (Pc) + 0.24 [ARDS(Ps)] + 1343; N = 146, r2 0.733, P less than 0.0001. However, sera (Ps or Ns) was required, as incubation in G inhibited LE; [cells + s] greater than [cells + G], P less than 0.0001. LE is a biologic marker of ARDS, and the delay between injury and the LE indicated that initiation of ARDS may have therapeutic importance. Neutrophil activation in ARDS requires sera, but the ARDS effect appears mainly due to cells with only a small ARDS-specific serum-mediated role. The physiologic response to ARDS was evaluated by serial 8-hr studies of blood gases and pH; the respiratory index (RI) to pulmonary shunt (QS/QT) relationship, compliance (COMPL), and net fluid balance (DFLUID) PMN and platelet (PLAT) counts were also measured. Compared with TR and TS, the ARDS patients at 48-96 hr, showed increased RI, QS/QT, and DFluid requiring increased FiO2 and PEEP as COMPL and PLAT fell and LE rose. These changes

  14. Tracheal gas insufflation combined with high-frequency oscillatory ventilation.

    PubMed

    Dolan, S; Derdak, S; Solomon, D; Farmer, C; Johanningman, J; Gelineau, J; Smith, R B

    1996-03-01

    on the direction and rate of gas flow. The beneficial effects of tracheal gas insufflation may be tempered by the long-term effects of altering distal airway pressure; lowering distal airway pressure may lead to atelectasis, whereas raising distal airway pressure may lead to an auto-positive end-expiratory pressure (auto-PEEP) effect.

  15. Hypothermic total liquid ventilation after experimental aspiration-associated acute respiratory distress syndrome.

    PubMed

    Rambaud, Jérôme; Lidouren, Fanny; Sage, Michaël; Kohlhauer, Matthias; Nadeau, Mathieu; Fortin-Pellerin, Étienne; Micheau, Philippe; Zilberstein, Luca; Mongardon, Nicolas; Ricard, Jean-Damien; Terada, Megumi; Bruneval, Patrick; Berdeaux, Alain; Ghaleh, Bijan; Walti, Hervé; Tissier, Renaud

    2018-05-02

    Ultrafast cooling by total liquid ventilation (TLV) provides potent cardio- and neuroprotection after experimental cardiac arrest. However, this was evaluated in animals with no initial lung injury, whereas out-of-hospital cardiac arrest is frequently associated with early-onset pneumonia, which may lead to acute respiratory distress syndrome (ARDS). Here, our objective was to determine whether hypothermic TLV could be safe or even beneficial in an aspiration-associated ARDS animal model. ARDS was induced in anesthetized rabbits through a two-hits model including the intra-tracheal administration of a pH = 1 solution mimicking gastric content and subsequent gaseous non-protective ventilation during 90 min (tidal volume [Vt] = 10 ml/kg with positive end-expiration pressure [PEEP] = 0 cmH 2 O). After this initial period, animals either received lung protective gas ventilation (LPV; Vt = 8 ml/kg and PEEP = 5 cmH 2 O) under normothermic conditions, or hypothermic TLV (TLV; Vt = 8 ml/kg and end-expiratory volume = 15 ml/kg). Both strategies were applied for 120 min with a continuous monitoring of respiratory and cardiovascular parameters. Animals were then euthanized for pulmonary histological analyses. Eight rabbits were included in each group. Before randomization, all animals elicited ARDS with arterial oxygen partial pressure over inhaled oxygen fraction ratios (PaO 2 /FiO 2 ) below 100 mmHg, as well as decreased lung compliance. After randomization, body temperature rapidly decreased in TLV versus LPV group (32.6 ± 0.6 vs. 38.2 ± 0.4 °C after 15 min). Static lung compliance and gas exchanges were not significantly different in the TLV versus LPV group (PaO 2 /FiO 2  = 62 ± 4 vs. 52 ± 8 mmHg at the end of the procedure, respectively). Mean arterial pressure and arterial bicarbonates levels were significantly higher in TLV versus LPV. Histological analysis also showed significantly lower inflammation in

  16. Hemodynamic profile of pulmonary hypertension (PH) in ARDS.

    PubMed

    Calcaianu, George; Calcaianu, Mihaela; Gschwend, Anthony; Canuet, Matthieu; Meziani, Ferhat; Kessler, Romain

    2018-01-01

    Acute respiratory distress syndrome (ARDS) is a diffuse lung injury that leads to a severe acute respiratory failure. Traditional diagnostic criteria for pulmonary hypertension (PH), in this situation, may be unreliable due to the effects of positive pressure ventilation and vasoactive agents. The aim of this study is to describe the hemodynamic characteristics of PH secondary to ARDS, in relation with respiratory parameters. We assessed the hemodynamic, respiratory function, and ventilator parameters in a cohort of 38 individuals with ARDS-associated PH defined by mean pulmonary arterial pressure (mPAP) ≥ 25 mmHg. Individual characteristics: PaO2/FiO2 = 110 ± 60 mmHg, alveolar-arterial oxygen gradient (A-aO2) = 549 ± 148.9 mmHg, positive end-expiratory pressure (PEEP) = 8.7 ± 3.5 cmH 2 O, pulmonary static compliance (Cstat) = 30 ± 12.1 L*cmH 2 O-1, mPAP = 35.4 ±6.6 mmHg, pulmonary artery wedge pressure (PAWP) = 15.6 ± 5.5 mmHg, cardiac index (CI) = 3.4 ± 1.2 L/min/m 2 , pulmonary vascular resistance (PVR) = 3.3 ± 1.6 Wood units (WU), right atrial pressure (RAP) = 13.4 ± 5.4 mmHg, diastolic pulmonary gradient (DPG) = 12.6 ± 6.5 mmHg, and trans-pulmonary gradient (TPG) = 19.7 ± 7.7 mmHg. The composite marker-DPG >7 mmHg and PVR > 3 WU-is associated with lower CI ( P = 0.016), higher mPAP ( P = 0.003), and lower pulmonary static compliance ( P = 0.028). We confirmed a poor prognosis of ARDS associated with PH, with a 50% survival rate after 17 days. We observed that the survival rate at 28 days was better in the case of improvement in the PaO2/FiO2 ratio in the first 24 h (log rank P = 0.003). ARDS associated with PH is a severe condition with a very poor survival rate. The composite marker DPG > 7 mmHg and PVR > 3 WU seemed to better describe the hemodynamic and respiratory dysfunction. The improvement in Pa

  17. Effect of Heat Moisture Exchanger on Aerosol Drug Delivery and Airway Resistance in Simulated Ventilator-Dependent Adults Using Jet and Mesh Nebulizers.

    PubMed

    Ari, Arzu; Dang, Truong; Al Enazi, Fahad H; Alqahtani, Mohammed M; Alkhathami, Abdulrahman; Qoutah, Rowaida; Almamary, Ahmad S; Fink, James B

    2018-02-01

    Placement of a heat moisture exchanger (HME) between aerosol generator and patient has been associated with greatly reduced drug delivery. The purpose of this study was to evaluate the effect of filtered and nonfiltered HMEs placed between nebulizer and patient on aerosol deposition and airway resistance (Raw) in simulated ventilator-dependent adults. An in vitro lung model was developed to simulate a mechanically ventilated adult (Vt 500 mL, RR 15/min, and PEEP 5 cmH 2 O, using two inspiratory flow rates 40 and 50 L/min) using an intubated adult manikin with an endotracheal tube (8 mmID). The bronchi of the manikin were connected to a Y-adapter through a collecting filter (Respirgard II) attached to a test lung through a heated humidifier (37°C producing 100% relative humidity) to simulate exhaled humidity. For treatment conditions, a nonfiltered HME (ThermoFlo™ 6070; ARC Medical) and filtered HMEs (ThermoFlo™ Filter; ARC Medical and PALL Ultipor; Pall Medical) were placed between the ventilator circuit at the endotracheal tube and allowed to acclimate to the exhaled heat and humidity for 30 minutes before aerosol administration. Airway resistance (cmH 2 O/L/s) was taken at 0, 10, 20, and 30 minutes after HME placement and after each of four aerosol treatments. Albuterol sulfate (2.5 mg/3 mL) was administered with jet (Misty Max 10; Airlife) and mesh (Aerogen Solo; Aerogen) nebulizers positioned in the inspiratory limb proximal to the Y-adapter. Control consisted of nebulization with no HME. Drug was eluted from filter at the end of the trachea and measured using spectrophotometry (276 nm). Greater than 60% of the control dose was delivered through the ThermoFlo. No significant difference was found between the first four treatments given by the jet (p = 0.825) and the mesh (p = 0.753) nebulizers. There is a small increase in Raw between pre- and post-four treatments with the jet (p = 0.001) and mesh (p = 0.015) nebulizers. Aerosol

  18. Impact of large volume paracentesis on respiratory parameters including transpulmonary pressure and on transpulmonary thermodilution derived hemodynamics: A prospective study

    PubMed Central

    Mayr, Ulrich; Karsten, Eugen; Lahmer, Tobias; Rasch, Sebastian; Thies, Philipp; Henschel, Benedikt; Fischer, Gerrit; Schmid, Roland M.

    2018-01-01

    cirrhosis, intraabdominal hypertension resulted in a substantially decreased TPP despite PEEP-setting according to the ARDSNet. In these patients LVP markedly increased TPP and improved respiratory function in parallel with a decline of EP. Furthermore, LVP induced a decrease in IAP and CVP, while other hemodynamic parameters did not change. PMID:29538440

  19. Hemodynamic profile of pulmonary hypertension (PH) in ARDS

    PubMed Central

    Calcaianu, Mihaela; Gschwend, Anthony; Canuet, Matthieu; Meziani, Ferhat; Kessler, Romain

    2017-01-01

    Acute respiratory distress syndrome (ARDS) is a diffuse lung injury that leads to a severe acute respiratory failure. Traditional diagnostic criteria for pulmonary hypertension (PH), in this situation, may be unreliable due to the effects of positive pressure ventilation and vasoactive agents. The aim of this study is to describe the hemodynamic characteristics of PH secondary to ARDS, in relation with respiratory parameters. We assessed the hemodynamic, respiratory function, and ventilator parameters in a cohort of 38 individuals with ARDS-associated PH defined by mean pulmonary arterial pressure (mPAP) ≥ 25 mmHg. Individual characteristics: PaO2/FiO2 = 110 ± 60 mmHg, alveolar-arterial oxygen gradient (A-aO2) = 549 ± 148.9 mmHg, positive end-expiratory pressure (PEEP) = 8.7 ± 3.5 cmH2O, pulmonary static compliance (Cstat) = 30 ± 12.1 L*cmH2O-1, mPAP = 35.4 ±6.6 mmHg, pulmonary artery wedge pressure (PAWP) = 15.6 ± 5.5 mmHg, cardiac index (CI) = 3.4 ± 1.2 L/min/m2, pulmonary vascular resistance (PVR) = 3.3 ± 1.6 Wood units (WU), right atrial pressure (RAP) = 13.4 ± 5.4 mmHg, diastolic pulmonary gradient (DPG) = 12.6 ± 6.5 mmHg, and trans-pulmonary gradient (TPG) = 19.7 ± 7.7 mmHg. The composite marker—DPG >7 mmHg and PVR > 3 WU—is associated with lower CI (P = 0.016), higher mPAP (P = 0.003), and lower pulmonary static compliance (P = 0.028). We confirmed a poor prognosis of ARDS associated with PH, with a 50% survival rate after 17 days. We observed that the survival rate at 28 days was better in the case of improvement in the PaO2/FiO2 ratio in the first 24 h (log rank P = 0.003). ARDS associated with PH is a severe condition with a very poor survival rate. The composite marker DPG > 7 mmHg and PVR > 3 WU seemed to better describe the hemodynamic and respiratory dysfunction. The improvement in PaO2/Fi

  20. Comparison of rSP-C surfactant with natural and synthetic surfactants after late treatment in a rat model of the acute respiratory distress syndrome

    PubMed Central

    Häfner, Dietrich; Germann, Paul-Georg; Hauschke, Dieter

    1998-01-01

    In a previous paper we showed that an SP-C containing surfactant preparation has similar activity as bovine-derived surfactants in a rat lung lavage model of the adult respiratory distress syndrome. In this study surfactant was given ten minutes after the last lavage (early treatment). In the present investigation we were interested how different surfactant preparations behave when they are administered 1 h after the last lavage (late treatment). Four protein containing surfactants (rSP-C surfactant, bLES, Infasurf and Survanta) were compared with three protein-free surfactants (ALEC, Exosurf and the phospholipid (PL) mixture of the rSP-C surfactant termed PL surfactant) with respect to their ability to improve gas exchange in this more stringent model when surfactant is given one hour after the last lavage. For better comparison of the surfactants the doses were related to phospholipids. The surfactants were given at doses of 25, 50 and 100 mg kg−1 body weight. The surfactants were compared to an untreated control group that was only ventilated for the whole experimental period. Tracheotomized rats (8–12 per dose and surfactant) were pressure-controlled ventilated (Siemens Servo Ventilator 900C) with 100% oxygen at a respiratory rate of 30 breaths min−1, inspiration expiration ratio of 1 : 2, peak inspiratory pressure of 28 cmH2O at positive endexpiratory pressure (PEEP) of 8 cmH2O. Animals were ventilated for one hour after the last lavage and thereafter the surfactants were intratracheally instilled. During the whole experimental period the ventilation was not changed. Partial arterial oxygen pressures (PaO2, mmHg) at 30 min and 120 min after treatment were used for statistical comparison. All protein containing surfactants caused a dose-dependent increase of the reduced PaO2 values at 30 min after treatment. The protein-free surfactants showed only weak dose-dependent increase in PaO2 values at this time. This difference between the

  1. Improved lung recruitment and oxygenation during mandatory ventilation with a new expiratory ventilation assistance device: A controlled interventional trial in healthy pigs.

    PubMed

    Schmidt, Johannes; Wenzel, Christin; Mahn, Marlene; Spassov, Sashko; Cristina Schmitz, Heidi; Borgmann, Silke; Lin, Ziwei; Haberstroh, Jörg; Meckel, Stephan; Eiden, Sebastian; Wirth, Steffen; Buerkle, Hartmut; Schumann, Stefan

    2018-05-04

    = 0.002) compared with control. EVA ventilation improves lung aeration via elevated mean tracheal pressure and consequently improves arterial oxygenation at unaltered positive end-expiratory pressure (PEEP) and peak inspiratory pressure (PIP). These findings suggest the EVA mode is a new approach for protective lung ventilation.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0.

  2. [General anesthesia vs. retrobulbar anesthesia in cataract surgery. A randomized comparison of patients at risk].

    PubMed

    Heinze, J; Rohrbach, M

    1992-08-01

    Several studies comparing retrobulbar block (RB) and general anaesthesia (GA) for cataract surgery in the elderly have been published. Most of them were retrospective. Our prospective study was designed in order to determine the benefits or disadvantages using RB or GA. Arterial blood gases (ABG) and cardiovascular stability were explored in high-risk patients undergoing elective unilateral cataract extraction. METHODS. Forty patients over 65 years of age and with other co-existing diseases (ASA III-IV) were allocated randomly to receive either GA or RB. No premedication was given to either group of patients. On arrival in the anaesthetic room, a radial artery was cannulated for collection of blood samples and direct monitoring of the blood pressure. Pulse oximetry and ECG were continuously monitored in all patients, the end-expiratory CO2 (F(eexCO2)) only in the GA group. GA was induced with vecuronium 0.1 mg/kg and thiopentone 5 mg/kg; the lungs were ventilated with 100% oxygen. After intubation of the trachea controlled mechanical ventilation was continued with N2O/O2 (55:45) and enflurane 1%-2%. Only enflurane concentrations were varied to correct changes in mean arterial pressure (MAP) if these exceeded +/- 20%. Respiratory frequency and tidal volume were kept constant until completion of surgery. The patients were extubated when they were able to ventilate more than 5 1/min (pressure support 10 cmH2O; PEEP 5 cmH2O). After extubation no O2 was given. In the RB group neural block was undertaken with prilocaine 2% (3 ml) as a retrobulbar injection and prilocaine 1% (5 ml) to block the facial innervation of the orbicularis muscle (Van Lint, O'Brien). Oxygen 3 1/min was administered by nasal tube during the operation. Nine arterial samples for blood gas analysis were collected: (1) control; (2) before operation; (3) 5 min after beginning the operation; (4) 15 min after beginning the operation and before i.v. administration of 500 mg acetazolamide over 5 min; (5

  3. [Experimental study on effect of airway pressure on cardiopulmonary resuscitation].

    PubMed

    Tan, Dingyu; Sun, Feng; Fu, Yangyang; Shao, Shihuan; Zhang, Yazhi; Hu, Yingying; Xu, Jun; Zhu, Huadong; Yu, Xuezhong

    2017-06-01

    To observe the effect of different airway pressure on ventilation, organ perfusion and return of spontaneous circulation (ROSC) of cardiac arrest (CA) pigs during cardiopulmonary resuscitation (CPR), and to explore the possible beneficial mechanism of positive airway pressure during CPR. Twenty healthy landrace pigs of clean grade were divided into low airway pressure group (LP group, n = 10) and high airway pressure group (HP group, n = 10) with random number table. The model of ventricular fibrillation (VF) was reproduced by electrical stimulation, and mechanical chest compressions and mechanical ventilation (volume-controlled mode, tidal volume 7 mL/kg, frequency 10 times/min) were performed after 8 minutes of untreated VF. Positive end expiratory pressure (PEEP) in LP group and HP group was set to 0 cmH 2 O and 6 cmH 2 O (1 cmH 2 O = 0.098 kPa) respectively. Up to three times of 100 J biphasic defibrillation was delivered after 10 minutes of CPR. The ROSC of animals were observed, and the respiratory parameters, arterial and venous blood gas and hemodynamic parameters were recorded at baseline, 5 minutes and 10 minutes of CPR. The number of animals with ROSC in the HP group was significantly more than that in the LP group (8 vs. 3, P < 0.05). Intrathoracic pressure during chest compression relaxation was negative in the HP group, and its absolute value was significantly lower than that in LP group at the same time [intrathoracic negative pressure peak (cmH 2 O): -4.7±2.2 vs. -10.8±3.5 at 5 minutes, -3.9±2.8 vs. -6.5±3.4 at 10 minutes], however, there was significantly difference only at 5 minutes of CPR (P < 0.01). Intrathoracic pressure variation during CPR period in the HP group were significantly higher than those in the LP group (cmH 2 O: 22.5±7.9 vs. 14.2±4.4 at 5 minutes, 23.1±6.4 vs. 12.9±5.1 at 10 minutes, both P < 0.01). Compared to the LP group, arterial partial pressure of oxygen [PaO 2 (mmHg, 1 mmHg = 0.133 kPa): 81.5±10.7 vs. 68.0±12

  4. [The clinical effect of airway pressure release ventilation for acute lung injury/acute respiratory distress syndrome].

    PubMed

    Song, Shaohua; Tian, Huiyu; Yang, Xiufen; Hu, Zhenjie

    2016-01-01

    To evaluate the effect of airway pressure release ventilation (APRV) in patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS), to evaluate the extent of ventilator-induced lung injury (VILI), and to explore its possible mechanism. A prospective study was conducted in the Department of Critical Care Medicine of the First Hospital of Hebei Medical University from December 2010 to February 2012. The patients with ALI/ARDS were enrolled. They were randomly divided into two groups. The patients in APRV group were given APRV pattern, while those in control group were given lung protection ventilation, synchronized intermittent mandatory ventilation with positive end-expiratory pressure (SIMV+PEEP). All patients were treated with AVEA ventilator. The parameters such as airway peak pressure (Ppeak), mean airway pressure (Pmean), pulse oxygen saturation (SpO2), mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP), arterial blood gas, urine output (UO), the usage of sedation and muscle relaxation drugs were recorded. AVEA ventilator "turning point (Pflex) operation" was used to describe the quasi-static pressure volume curve (P-V curve). High and low inflection point (UIP, LIP) and triangular Pflex volume (Vdelta) were automatically measured and calculated. The ventilation parameters were set, and the 24-hour P-V curve was recorded again in order to be compared with subsequent results. Venous blood was collected before treatment, 24 hours and 48 hours after ventilation to measure lung surfactant protein D (SP-D) and large molecular mucus in saliva (KL-6) by enzyme linked immunosorbent assay (ELISA), and the correlation between the above two parameters and prognosis on 28 days was analyzed by multinomial logistic regression. Twenty-six patients with ALI/ARDS were enrolled, and 22 of them completed the test with 10 in APRV group and 12 in control group. The basic parameters and P-V curves between two groups were similar before

  5. Continuous positive airway pressure (CPAP) during the postoperative period for prevention of postoperative morbidity and mortality following major abdominal surgery.

    PubMed

    Ireland, Claire J; Chapman, Timothy M; Mathew, Suneeth F; Herbison, G Peter; Zacharias, Mathew

    2014-08-01

    Major abdominal surgery can be associated with a number of serious complications that may impair patient recovery. In particular, postoperative pulmonary complications (PPCs), including respiratory complications such as atelectasis and pneumonia, are a major contributor to postoperative morbidity and may even contribute to increased mortality. Continuous positive airway pressure (CPAP) is a type of therapy that uses a high-pressure gas source to deliver constant positive pressure to the airways throughout both inspiration and expiration. This approach is expected to prevent some pulmonary complications, thus reducing mortality. To determine whether any difference can be found in the rate of mortality and adverse events following major abdominal surgery in patients treated postoperatively with CPAP versus standard care, which may include traditional oxygen delivery systems, physiotherapy and incentive spirometry. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) 2013, Issue 9; Ovid MEDLINE (1966 to 15 September 2013); EMBASE (1988 to 15 September 2013); Web of Science (to September 2013) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (to September 2013). We included all randomized controlled trials (RCTs) in which CPAP was compared with standard care for prevention of postoperative mortality and adverse events following major abdominal surgery. We included all adults (adults as defined by individual studies) of both sexes. The intervention of CPAP was applied during the postoperative period. We excluded studies in which participants had received PEEP during surgery. Two review authors independently selected studies that met the selection criteria from all studies identified by the search strategy. Two review authors extracted the data and assessed risk of bias separately, using a data extraction form. Data entry into RevMan was performed by one review author and was checked by another for accuracy. We performed a

  6. [Effect of airway humidification on lung injury induced by mechanical ventilation].

    PubMed

    Song, Junjie; Jiang, Min; Qi, Guiyan; Xie, Yuying; Wang, Huaiquan; Tian, Yonggang; Qu, Jingdong; Zhang, Xiaoming; Li, Haibo

    2014-12-01

    To explore the effect of airway humidification on lung injury as a result of mechanical ventilation with different tidal volume (VT). Twenty-four male Japanese white rabbits were randomly divided into four groups: low VT with airway humidification group, high VT with airway humidification group, low VT and high VT group without humidification, with 6 rabbits in each group. Mechanical ventilation was started after intubation and lasted for 6 hours. Low VT denoted 8 mL/kg, while high VT was 16 mL/kg, fraction of inspired oxygen (FiO₂) denoted 0.40, positive end-expiratory pressure (PEEP) was 0. Temperature at Y piece of circuit in airway humidification groups was monitored and controlled at 40 centigrade. Arterial blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO₂), arterial partial pressure of carbon dioxide (PaCO₂), lung mechanics indexes, including peak airway pressure (P(peak)) and airway resistance (Raw), and lung compliance was measured at 0, 2, 4, 6 hours of mechanical ventilation. The levels of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in plasma and bronchoalveolar lavage fluid (BALF) were determined by enzyme linked immunosorbent assay (ELISA). The animals were sacrificed at the end of mechanical ventilation. The wet to dry (W/D) ratio of lung tissues was calculated. Histopathologic changes in the lung tissueies were observed with microscope, and lung injury score was calculated. Scanning and transmission electron microscopies were used to examine the integrity of the airway cilia and the tracheal epithelium. Compared with low V(T) group, pH value in high V(T) group was significantly increased, PaCO₂was significantly lowered, and no difference in PaO₂was found. P(peak), Raw, and lung compliance were significantly increased during mechanical ventilation. There were no significant differences in blood gas analysis and lung mechanics indexes between low V(T) with airway humidification group and low V