Sample records for joint base operations

  1. Joint Forward Operating Base Elements of Command and Control

    NASA Astrophysics Data System (ADS)

    Summers, William C.

    2002-01-01

    Since the 1986 Goldwater-Nichols Act directed the Chairman of the Joint Chiefs of Staff to develop doctrine for the joint employment of the armed forces, tactics, techniques, and procedures have evolved at different rates depending on the competency. Whereas the command of joint air forces is well prescribed within the structure of the air operations center and its associated leadership, command of air assets at a joint forward operating base lacks guidance. Today, the United States prosecutes an air war over Afghanistan from bases in Uzbekistan, Pakistan, and Afghanistan. Elements of the United States Army, Air Force, and Marines combine at these geographically minute locations, each bringing a certain complement of support and command and control. Evidence from operations during the 1999 air war for Kosovo at Tirana Rinas Airport in Albania suggests that when these service elements meet at the airfield for the first time, there are problems associated with local procedure. At best, time is wasted creating local joint systems to overcome the difficulties. At worst, safety and mission accomplishment are jeopardized. This thesis will address the need to develop doctrine and a jointly integrated organization to support the command and control function at a forward operating base.

  2. Correlation-based regularization and gradient operators for (joint) inversion on unstructured meshes

    NASA Astrophysics Data System (ADS)

    Jordi, Claudio; Doetsch, Joseph; Günther, Thomas; Schmelzbach, Cedric; Robertsson, Johan

    2017-04-01

    When working with unstructured meshes for geophysical inversions, special attention should be paid to the design of the operators that are used for regularizing the inverse problem and coupling of different property models in joint inversions. Regularization constraints for inversions on unstructured meshes are often defined in a rather ad-hoc manner and usually only involve the cell to which the operator is applied and its direct neighbours. Similarly, most structural coupling operators for joint inversion, such as the popular cross-gradients operator, are only defined in the direct neighbourhood of a cell. As a result, the regularization and coupling length scales and strength of these operators depend on the discretization as well as cell sizes and shape. Especially for unstructured meshes, where the cell sizes vary throughout the model domain, the dependency of the operator on the discretization may lead to artefacts. Designing operators that are based on a spatial correlation model allows to define correlation length scales over which an operator acts (called footprint), reducing the dependency on the discretization and the effects of variable cell sizes. Moreover, correlation-based operators can accommodate for expected anisotropy by using different length scales in horizontal and vertical directions. Correlation-based regularization operators also known as stochastic regularization operators have already been successfully applied to inversions on regular grids. Here, we formulate stochastic operators for unstructured meshes and apply them in 2D surface and 3D cross-well electrical resistivity tomography data inversion examples of layered media. Especially for the synthetic cross-well example, improved inversion results are achieved when stochastic regularization is used instead of a classical smoothness constraint. For the case of cross-gradients operators for joint inversion, the correlation model is used to define the footprint of the operator and weigh

  3. Joint Newspaper Operating Agreements.

    ERIC Educational Resources Information Center

    Parsons, Marie

    The number of competing daily newspapers in American cities has dwindled until only about 50 cities boast two papers. Of the newspapers in those cities, 23 now maintain separate editorial operations but have joint printing, advertising, and circulation departments. The concept of joint operation is 50 years old, dating from the Depression years…

  4. The Joint Master Operational Planner

    DTIC Science & Technology

    2016-04-04

    Daniel H. Hibner, United States Army Joint Forces Staff College Joint Advanced Warfighting School 7800 Hampton Blvd. Norfolk, VA 23511-1702 Approved...Operational Art. Unclass Unclass Unclass Unclassified Unlimited 66 757-443-6301 NATIONAL DEFENSE UNIVERSITY JOINT FORCES STAFF COLLEGE JOINT ADVANCED...of this paper reflect my own personal views and are not necessarily endorsed by the Joint Forces Staff College or the department of Defense. Thesis

  5. Joint chemical defense for the rear battle: main operating bases in NATO's central region. Student report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salmi, M.D.

    In 1984, the Chiefs of Staff of the US Army and the US Air Force signed a Memorandum of Understanding (MOU) outlining a concept for the joint air defense of overseas air bases. With little previous experience in joint rear-area operations, problems were bound to occur, especially in the area of chemical warfare defense (CWD). The Army bases its CWD doctrine on the concept of maneuver while the Air Force bases its doctrine on being tied to air bases with little or no capability to avoid chemical attacks. Each Service developed its doctrine to support its operational concept. This studymore » compared and contrasted the CWD doctrine of the Army and the Air Force. If found a great deal of commonality exists; however, there are also several problems which could lead to death, injury, and degradation of sortie generation capability.« less

  6. Space Weather Forecasting at the Joint Space Operations Center (JSpOC)

    NASA Astrophysics Data System (ADS)

    Nava, O.

    2012-12-01

    The Joint Space Operations Center (JSpOC) at Vandenberg Air Force Base is the command and control focal point for the operational employment of worldwide joint space forces. The JSpOC focuses on planning and executing US Strategic Command's Joint Functional Component Command for Space (JFCC SPACE) mission. Through the JSpOC, the Weather Specialty Team (WST) monitors space and terrestrial weather effects, plans and assesses weather impacts on military operations, and provides reach-back support for deployed theater solar and terrestrial needs. This presentation will detail how space weather affects the JSpOC mission set and how the scientific community can enhance the WST's capabilities and effectiveness.

  7. Mortuary Affairs in Joint Operations

    DTIC Science & Technology

    2006-06-05

    regulations, and doctrine. For the Chairman of the Joint Chiefs of Staff: WALTER L. SHARP Lieutenant General , USA Director, Joint Staff SUMMARY OF...Introduction ........................................................................................................... VII-1 • General Guidance...disposition of human remains ( PADD ); maintaining temporary interment sites including the recording of interment and disinterment actions; operation of the

  8. Joint Chiefs of Staff > Directorates > J3 | Operations

    Science.gov Websites

    Joint Staff Structure Joint Staff Inspector General Origin of Joint Concepts U.S. Code | Joint Chiefs of J8 | Force Structure, Resources & Assessment Contact J3 Operations Home : Directorates : J3

  9. Deficiencies in Indian Joint Operations

    DTIC Science & Technology

    2016-05-26

    Pakistan Navy escorted its oil tankers along the Makran Coast to avoid a naval engagement. The key tasks for Operation Talwar included preventing... Informatics plays a major role in ensuring that intelligence is available in time and in the desired form. The US Principles of Joint Operations59 1

  10. Future Operating Concept - Joint Computer Network Operations

    DTIC Science & Technology

    2010-02-17

    into the system‖ at a later date by circumventing the need for access privileges 3. Cyberwarfare Tools 67 • Social Engineering • Hacking ...Forces Command, Joint Operating Environment 2008, November 2008https://us.jfcom.mil/sites/ J5 /j59/default.aspx VIII Appendix V

  11. Revitalizing Nuclear Operations in the Joint Environment

    DTIC Science & Technology

    2014-02-01

    height of the Cold War, US schol - ars and joint operational planners were working simultaneously on weapons development and operational art to employ...leadership’s large-target- category withholds thought necessary to maintain stability in a strategic crisis. The inclusion of nuclear effects and...escalation. The inclusion of these points in tomorrow’s doctrine as well as an intellec- tual discussion on the topic will inform Joint Staff planners

  12. JOMAR: Joint Operations with Mobile Autonomous Robots

    DTIC Science & Technology

    2015-12-21

    AFRL-AFOSR-JP-TR-2015-0009 JOMAR: Joint Operations with Mobile Autonomous Robots Edwin Olson UNIVERSITY OF MICHIGAN Final Report 12/21/2015...SUBTITLE JOMAR: Joint Operations with Mobile Autonomous Robots 5a. CONTRACT NUMBER FA23861114024 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...14. ABSTRACT Under this grant, we formulated and implemented a variety of novel algorithms that address core problems in multi- robot systems. These

  13. Discussion on joint operation of wind farm and pumped-storage hydroplant

    NASA Astrophysics Data System (ADS)

    Li, Caifang; Wu, Yichun; Liang, Hao; Li, Miao

    2017-12-01

    Due to the random fluctuations in wind power, large amounts of grid integration will have a negative impact on grid operation and the consumers. The joint operation with pumped-storage hydroplant with good peak shaving performance can effectively reduce the negative impact on the safety and economic operation of power grid, and improve the utilization of wind power. In addition, joint operation can achieve the optimization of green power and improve the comprehensive economic benefits. Actually, the rational profit distribution of joint operation is the premise of sustainable and stable cooperation. This paper focuses on the profit distribution of joint operation, and applies improved shapely value method, which taking the investments and the contributions of each participant in the cooperation into account, to determine the profit distribution. Moreover, the distribution scheme can provide an effective reference for the actual joint operation of wind farm and pumped-storage hydroplant.

  14. Joint operations planning for space surveillance missions on the MSX satellite

    NASA Technical Reports Server (NTRS)

    Stokes, Grant; Good, Andrew

    1994-01-01

    The Midcourse Space Experiment (MSX) satellite, sponsored by BMDO, is intended to gather broad-band phenomenology data on missiles, plumes, naturally occurring earthlimb backgrounds and deep space backgrounds. In addition the MSX will be used to conduct functional demonstrations of space-based space surveillance. The JHU/Applied Physics Laboratory (APL), located in Laurel, MD, is the integrator and operator of the MSX satellite. APL will conduct all operations related to the MSX and is charged with the detailed operations planning required to implement all of the experiments run on the MSX except the space surveillance experiments. The non-surveillance operations are generally amenable to being defined months ahead of time and being scheduled on a monthly basis. Lincoln Laboratory, Massachusetts Institute of Technology (LL), located in Lexington, MA, is the provider of one of the principle MSX instruments, the Space-Based Visible (SBV) sensor, and the agency charged with implementing the space surveillance demonstrations on the MSX. The planning timelines for the space surveillance demonstrations are fundamentally different from those for the other experiments. They are generally amenable to being scheduled on a monthly basis, but the specific experiment sequence and pointing must be refined shortly before execution. This allocation of responsibilities to different organizations implies the need for a joint mission planning system for conducting space surveillance demonstrations. This paper details the iterative, joint planning system, based on passing responsibility for generating MSX commands for surveillance operations from APL to LL for specific scheduled operations. The joint planning system, including the generation of a budget for spacecraft resources to be used for surveillance events, has been successfully demonstrated during ground testing of the MSX and is being validated for MSX launch within the year. The planning system developed for the MSX forms a

  15. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... OF AGRICULTURE GENERAL REGULATIONS AND POLICIES PAYMENT LIMITATION AND PAYMENT ELIGIBILITY FOR 2009 AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A...

  16. Operation Joint Guard (SFOR) Bosnia. Assessment of Operational Stress and Adaptive Coping Mechanisms of Soldiers

    DTIC Science & Technology

    1998-03-01

    married, 3 children, \\ more than two years w/company J V ^ I am constantly placed in an ethical dilemmas daily in front of my soldiers. I do...and lessons learned are presented . 14. SUBJECT TERMS Bosnia, Operation Joint Guard, Operation Joint Endeavor, Peacekeeping, Stress, Psychological...keeping operations present challenging environments to any military organization and its soldiers. Soldiers will often be required to perform their

  17. 76 FR 3157 - Joint Operations Center Relocation Project, Sacramento County, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... Water Resources (DWR), the lead State agency, will prepare a joint EIS/EIR for the proposed Joint... following departments: DWR's Division of Operations and Maintenance, Operations Control Office, State Water...

  18. What It Takes. Air Force Command of Joint Operations

    DTIC Science & Technology

    2009-01-01

    Iraq Assistance Group IDE intermediate developmental education IO international organization ISAF International Security and Assistance Force ISR...Operations Table A.1—Continued Joint Task Force Mission/Operation Start End Service Command Rank JTF–Joint Area Support Group (JASG) Iraqi Freedom...be of interest to a wide group of Air Force personnel involved in the development and func- tion of the service’s command organizations, including

  19. Command and Control for Joint Air Operations.

    DTIC Science & Technology

    1994-11-14

    publication apply to the throughout the range of military commanders of combatant commands, operations. subunified commands, joint task forces, and...this doctrine (or operations as well as the doctrinal basis JTTP) will be followed except when, in for US military involvement in the judgment of the...commander, multinational and interagency operations. exceptional circumstances dictate It provides military guidance for the otherwise. If conflicts

  20. Planning and conducting medical support to joint operations.

    PubMed

    Hughes, A S

    2000-01-01

    Operations are core business for all of us and the PJHQ medical cell is at the heart of this process. With the likelihood of a continuing UK presence in the Balkans for some time to come, the challenge of meeting this and any other new operational commitments will continue to demand a flexible and innovative approach from all concerned. These challenges together with the Joint and multinational aspects of the job make the PJHQ medical cell a demanding but rewarding place to work and provide a valuable Joint staff training opportunity for the RNMS.

  1. [Arthroscopic therapy of ankle joint impingement syndrome after operation of ankle joint fracture dislocation].

    PubMed

    Feng, Zhibin; Mi, Kun; Wei, Renzhi; Liu, Wu; Wang, Bin

    2011-07-01

    To study the operative procedure and the effectiveness of arthroscopic therapy for ankle joint impingement syndrome after operation of ankle joint fracture dislocation. Between March 2008 and April 2010, 38 patients with ankle joint impingement syndrome after operation of ankle joint fracture dislocation were treated. Among them, there were 28 males and 10 females with an average age of 28 years (range, 18 to 42 years). The time from internal fixation to admission was 12-16 months (mean, 13.8 months). There were pressing pain in anterolateral and anterior ankle. The dorsal extension ranged from -20 to -5 degrees (mean, -10.6 degrees), and the palmar flexion was 30-40 degrees (mean, 35.5 degrees). The total score was 48.32 +/- 9.24 and the pain score was 7.26 +/- 1.22 before operation according to American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. The X-ray films showed osteophyte formation in anterior tibia and talus; MRI showed cartilage injury in 22 cases. Arthroscopic intervention included removing osteophytes, debriding fabric scars and synovial membrane tissues, and removing osteochondral fragments. Arthroscopic microfracture technique was used in 22 patients with cartilage injury. All incisions healed primarily. Thirty-eight cases were followed up 10-26 months (mean, 16 months). At last follow-up, 26 patients had normal range of motion (ROM); the dorsal extension was 15-25 degrees (mean, 19.6 degrees) and the palmar flexion was 35-45 degrees (mean, 40.7 degrees). Eight patients had mild limited ROM; the dorsal extension was 5-15 degrees (mean, 7.2 degrees) and the palmar flexion was 35-45 degrees (mean, 39.5 degrees). Four patients had mild limited ROM and pain in posterior portion of the ankle after a long walking (3-4 hours); the dorsal extension was 0-5 degrees (mean, 2.6 degrees) and the palmar flexion was 35-40 degrees (mean, 37.5 degrees). The total score was 89.45 +/- 9.55 and the pain score was 1.42 +/- 1.26 after

  2. Derivation of optimal joint operating rules for multi-purpose multi-reservoir water-supply system

    NASA Astrophysics Data System (ADS)

    Tan, Qiao-feng; Wang, Xu; Wang, Hao; Wang, Chao; Lei, Xiao-hui; Xiong, Yi-song; Zhang, Wei

    2017-08-01

    The derivation of joint operating policy is a challenging task for a multi-purpose multi-reservoir system. This study proposed an aggregation-decomposition model to guide the joint operation of multi-purpose multi-reservoir system, including: (1) an aggregated model based on the improved hedging rule to ensure the long-term water-supply operating benefit; (2) a decomposed model to allocate the limited release to individual reservoirs for the purpose of maximizing the total profit of the facing period; and (3) a double-layer simulation-based optimization model to obtain the optimal time-varying hedging rules using the non-dominated sorting genetic algorithm II, whose objectives were to minimize maximum water deficit and maximize water supply reliability. The water-supply system of Li River in Guangxi Province, China, was selected for the case study. The results show that the operating policy proposed in this study is better than conventional operating rules and aggregated standard operating policy for both water supply and hydropower generation due to the use of hedging mechanism and effective coordination among multiple objectives.

  3. Bugs, Gas, and Joint Maritime Operations--Are we Immune?

    DTIC Science & Technology

    1992-06-19

    asPira::on - and an opp rtunity. ŗ Even with the collapse of Soviet communism , there are powers who would challenge our aspirations: a technological ... technological data are used to analyze the effects of chemica’l warfare on joint naval operations throughout the continuum of peace, conflict and war. A judgement...IM1MUNE? Historical and technological data are used to analyze the effects of chemical warfare on joint naval operations throughout the continuum of

  4. Apparatus for maintaining aligment of a shrinking weld joint in an electron-beam welding operation

    DOEpatents

    Trent, J.B.; Murphy, J.L.

    1980-01-03

    The invention is directed to an apparatus for automatically maintaining a shrinking weld joint in alignement with an electron beam during an electron-beam multipass-welding operation. The apparatus utilizes a bias means for continually urging a workpiece-supporting face plate away from a carriage mounted base that rotatably supports the face plate. The extent of displacement of the face plate away from the base in indicative of the shrinkage occuring in the weld joint area. This displacement is measured and is used to move the base on the carriage a distance equal to one-half the displacement for aligning the weld joint with the electron beam during each welding pass.

  5. Joint Forces Command - Operation United Assistance Case Study: Lessons and Best Practices

    DTIC Science & Technology

    2016-07-01

    additional and prioritized computers and access in the operations center for these mission requirements are essential. 127 JFC-OUA CASE STUDY Issue...this publication is welcomed and highly encouraged. Joint Forces Command – Operation United Assistance Case Study JFC-OUA CASE STUDY iii Foreword...Based on information drawn from various sources including after action reports, lessons learned, case studies , umbrella-week visits, and key-leader

  6. Apparatus for maintaining alignment of a shrinking weld joint in an electron-beam welding operation

    DOEpatents

    Trent, Jett B.; Murphy, Jimmy L.

    1981-01-01

    The present invention is directed to an apparatus for automatically maintaining a shrinking weld joint in alignment with an electron beam during an electron-beam multipass-welding operation. The apparatus utilizes a biasing device for continually urging a workpiece-supporting face plate away from a carriage mounted base that rotatably supports the face plate. The extent of displacement of the face plate away from the base is indicative of the shrinkage occuring in the weld joint area. This displacement is measured and is used to move the base on the carriage a distance equal to one-half the displacement for aligning the weld joint with the electron beam during each welding pass.

  7. Unassailable Advantage: The British Use of Principles of Joint Operations from 1758-1762

    DTIC Science & Technology

    2017-05-25

    operations are based on the Principles of War developed by Baron Antoine Henri de Jomini. The Art of War (London: Greenhill Books), 1992. 6 JP 3-0, Joint...appointment based on this ability and willingness, rather than seniority.46 Also, the landing boats for the Rochefort operation were unacceptable. The... equipped with rudders and small sails to increase control and speed.47 They had either 16 or 20 oarsmen and could carry about a half a company of

  8. Executive Report: JSOU (Joint Special Operations University) First Annual Symposium, 2-5 May 2006, Hurlburt Field, Florida

    DTIC Science & Technology

    2006-05-05

    NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Joint Special Operations University,357 Tully Street...Alison Building,Hurlburt Field,FL,32544 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR...leadership. JSOU is a subordinate organization of the US Special Operations Command (USSOCOM), MacDill Air Force Base, Florida. The mission of the Joint

  9. Operation Stabilise: U.S. Joint Force Operations in East Timor

    DTIC Science & Technology

    2001-04-01

    September 1999, while deliberating the issue, Adm Blair designated the USS Mobile Bay (CG 53) and the USNS Kilauea (T-AE 26) as Joint Task Force-Timor Sea...Timor Sea Operations, 7th Fleet, Pacific Fleet § USS MOBILE BAY (CG 53), CJTF TSO (CAPT Edward Rogers, USN) § USNS KILAUEA (T-AE 26) § USNS SAN JOSE (T

  10. Operative Versus Non-operative Treatment of Grade III Acromioclavicular Joint Dislocations and the Use of SurgiLig: a Retrospective Review.

    PubMed

    Younis, Fizan; Ajwani, Sanil; Bibi, Asia; Riley, Eleanor; Hughes, Peter J

    2017-12-30

    Acromioclavicular joint dislocations are common shoulder girdle injuries. The treatment of grade III acromioclavicular joint dislocations is controversial. Furthermore, the literature on the use of the Sur-giligTM synthetic ligament for reconstruction of dislocations is sparse. This retrospective review aimed to establish whether operative treatment was superior to non-operative treatment in grade III acromioclavicular joint dislocations treated at our institute over a 5-year period. We also reviewed the effectiveness of reconstruction with SurgiligTM after acute and chronic dislocations across all grades of acromioclavicular joint dislocations. Twenty-five patients completed full follow-up with grade III dislocations. The mean follow-up in the operated group was 3.56 years and in the non-operated group this was 3.29 years. The mean Oxford Shoul-der Score (OSS) in the operated group was 39.8, whereas the mean OSS in the non-operated group was 45.9 (p=0.01). The mean pain score in the operated group was 2.2, and in the non-operated group this was 1.6. The mean satisfaction score in the operated group was 8.2 and that in the non-operated group was 7.8. There was no statistically significant difference in pain or satisfaction scores. In respect to the cohort treated with Surg-iligTM synthetic ligament, 22 patients across all grades of dislocations had this procedure performed. The mean post-operative Oxford Shoulder Score (OSS) was 40. 1. Non-operative treatment is not inferior to operative treatment for grade III acromioclavicular joint dislocations. The data from this study demonstrat-ed that the non-operated group had superior Ox-ford Shoul-der Scores that were statistically significant. 2. Additionally, the use of the SurgiligTM ligament appears to be effective in treating both chronic and acute acromioclavicular joint dislocations.

  11. Space Situational Awareness in the Joint Space Operations Center

    NASA Astrophysics Data System (ADS)

    Wasson, M.

    2011-09-01

    Flight safety of orbiting resident space objects is critical to our national interest and defense. United States Strategic Command has assigned the responsibility for Space Situational Awareness (SSA) to its Joint Functional Component Command - Space (JFCC SPACE) at Vandenberg Air Force Base. This paper will describe current SSA imperatives, new developments in SSA tools and developments in Defensive Operations. Current SSA processes are being examined to capture, and possibly improve, tasking of SSN sensors and "new" space-based sensors, "common" conjunction assessment methodology, and SSA sharing due to the growth seen over the last two years. The stand-up of a Defensive Ops Branch will highlight the need for advanced analysis and collaboration across space, weather, intelligence, and cyber specialties. New developments in SSA tools will be a description of computing hardware/software upgrades planned as well as the use of User-Defined Operating Pictures and visualization applications.

  12. Joint Training In Combined Entry Operations

    DTIC Science & Technology

    2014-02-13

    AIR WAR COLLEGE AIR UNIVERSITY JOINT TRAINING IN COMBINED ENTRY OPERATIONS by Ethan Mitchell, CDR, USN A Research Report Submitted...government. DISTRIBUTION A . Approved for public release: distribution unlimited. 2 Biography CDR Ethan Mitchell is assigned to the Air War College...Areas of Responsibility. Ashore, her served in the requirements directorate on the Commander, Second Fleet staff and earned a Master’s of Science

  13. Joint Space Operations Center (JSpOC) Mission System Increment 3 (JMS Inc 3)

    DTIC Science & Technology

    2016-03-01

    2016 Major Automated Information System Annual Report Joint Space Operations Center (JSpOC) Mission System Increment 3 (JMS Inc 3) Defense...1725 DSN Phone: DSN Fax: Date Assigned: May 16, 2014 Program Information Program Name Joint Space Operations Center (JSpOC) Mission System...approved program baseline; therefore, no Original Estimate has been established. JMS Inc 3 2016 MAR UNCLASSIFIED 4 Program Description The Joint Space

  14. A methodology to enhance electromagnetic compatibility in joint military operations

    NASA Astrophysics Data System (ADS)

    Buckellew, William R.

    The development and validation of an improved methodology to identify, characterize, and prioritize potential joint EMI (electromagnetic interference) interactions and identify and develop solutions to reduce the effects of the interference are discussed. The methodology identifies potential EMI problems using results from field operations, historical data bases, and analytical modeling. Operational expertise, engineering analysis, and testing are used to characterize and prioritize the potential EMI problems. Results can be used to resolve potential EMI during the development and acquisition of new systems and to develop engineering fixes and operational workarounds for systems already employed. The analytic modeling portion of the methodology is a predictive process that uses progressive refinement of the analysis and the operational electronic environment to eliminate noninterfering equipment pairs, defer further analysis on pairs lacking operational significance, and resolve the remaining EMI problems. Tests are conducted on equipment pairs to ensure that the analytical models provide a realistic description of the predicted interference.

  15. [Fractures of the proximal interphalangeal joint: Diagnostic and operative therapy options].

    PubMed

    Unglaub, F; Langer, M F; Hahn, P; Müller, L P; Ahrens, C; Spies, C K

    2016-02-01

    Joint fractures of the fingers often entail operative interventions in contrast to extra-articular fractures. These types of fracture are inclined to dislocate in addition to the actual fracture. The proximal interphalangeal (PIP) joint in particular often shows comminuted fractures due to the long leverage of the finger and a relatively small diameter of the joint. The clinical examination, X-ray diagnostics and if necessary computed tomography allow the classification into stable and unstable fractures. Unstable fractures must be treated by surgical reduction and fixation. A multitude of operative techniques are available for these mostly complicated fractures. The foremost goal is a stable osteosynthesis of the fracture with repositioning of the dislocation, which enables early physiotherapy in order to prevent tendon adhesion and contracture. This article presents the different types of PIP joint fractures, their specific surgical treatment and postoperative treatment regimens.

  16. Joint Publication 3-31. Command and Control for Joint Land Operations

    DTIC Science & Technology

    2010-06-29

    task force] FALCON .” Admiral James Ellis, Commander, Joint Task Force NOBLE ANVIL during Operation ALLIED FORCE in letter correspondence to RAND...beneficial effect on the gr ound cam paign.” D uring t he ca mpaign, “ Army and M arine artillery were used interchangeably.” SOURCE: Lieutenant...consolidates, prioritizes, and forwards ultra -high frequency tactical satellite requirements to the JFC for channel allocation. k. Establishes, supervises

  17. Searching for Order Within Chaos: Complexity Theorys Implications to Intelligence Support During Joint Operational Planning

    DTIC Science & Technology

    2017-06-09

    structures constantly arise in firefights and skirmishes on the battlefield. Source: Andrew Ilachinski, Artificial War: Multiagent- Based Simulation of...Alternative Methods of Analysis and Innovative Organizational Structures .” Conference, Rome, Italy March 31-April 2. ...Intelligence Analysis, Joint Operational Planning, Cellular Automata, Agent- Based Modeling 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18

  18. Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP.

    PubMed

    Deng, Li; Wang, Guohua; Chen, Bo

    2015-01-01

    In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency.

  19. Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP

    PubMed Central

    Wang, Guohua; Chen, Bo

    2015-01-01

    In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency. PMID:26448740

  20. Joint Command and Control of Cyber Operations: The Joint Force Cyber Component Command (JFCCC)

    DTIC Science & Technology

    2012-05-04

    relies so heavily on complex command and control systems and interconnectivity in general, cyber warfare has become a serious topic of interest at the...defensive cyber warfare into current and future operations and plans. In particular, Joint Task Force (JTF) Commanders must develop an optimum method to

  1. Standing Joint Forces: Spearhead for Global Operational Maneuver

    DTIC Science & Technology

    2005-05-26

    Threat,” In The War Next Time: Countering Rogue States and Terrorists 1 20 NOVEMBER 2014 Operation Roundhouse was a resounding success. While...America’s " kick -down the door" force, capable of extremely rapid deployment from CONUS to anywhere in the world to ensure aerospace access for joint

  2. Joint Operating Environment 2035: The Joint Force in a Contested and Disordered World

    DTIC Science & Technology

    2016-07-14

    environment. Next, Section 2 explores how the intersection and interaction of these changes might impact the character of war in the future. Finally, Section...ideas about how changes to conflict and war might impact the capabilities and operational approaches required by the future Joint Force. These...1 Colin Gray, Another Bloody Century, (2005), p. 43. 2 challenges that will impact the

  3. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    PubMed

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value <0.001). The ASB isolate was the same microorganism as the PJI isolate in only one of the seven cases. The association between ASB and PJI is statistically significant, but the urine isolates did not relate to the isolates in the prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  4. Command and Control for Joint Air Operations

    DTIC Science & Technology

    2010-01-12

    systems, to include collaborative air planning tools such as the theater battle management core system ( TBMCS ). Operational level air planning occurs in...sight communications and data exchange equipment in order to respond to joint force requirements. For example, the TBMCS is often used. The use of ATO...generation and dissemination software portions of TBMCS has been standardized. This ATO feature allows the JAOC to be interoperable with other

  5. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    PubMed

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P<0.05), respectively. No statistical difference was observed between the two groups in palpation index (PI), dysfunction index (DI) and CMI (P>0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  6. 76 FR 13446 - Juniata Valley Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority Juniata Valley Railroad Company (JVRR... milepost 2.0 in Lewistown, Mifflin County, Pa. The line is owned or leased by SEDA-COG Joint Rail Authority (SEDA-COG). JVRR states that the line it proposes to operate is an extension of its existing line of...

  7. 76 FR 13445 - North Shore Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority North Shore Railroad Company (NSRR), a... milepost 2.0 in Berwick, Columbia County, Pa. The line is leased by SEDA-COG Joint Rail Authority (SEDA- COG). NSRR states that the line it proposes to operate is an extension of its existing line of...

  8. 76 FR 13445 - Lycoming Valley Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Railroad Company-Operation Exemption--SEDA--COG Joint Rail Authority Lycoming Valley Railroad Company (LVRR... milepost 0.4 in Muncy, Lycoming County, Pa. The line is owned or leased by SEDA-COG Joint Rail Authority (SEDA-COG). LVRR states that the line it proposes to operate is an extension of its existing line of...

  9. Multi-objective evolutionary optimization for the joint operation of reservoirs of water supply under water-food-energy nexus management

    NASA Astrophysics Data System (ADS)

    Uen, T. S.; Tsai, W. P.; Chang, F. J.; Huang, A.

    2016-12-01

    In recent years, urbanization had a great effect on the growth of population and the resource management scheme of water, food and energy nexus (WFE nexus) in Taiwan. Resource shortages of WFE become a long-term and thorny issue due to the complex interactions of WFE nexus. In consideration of rapid socio-economic development, it is imperative to explore an efficient and practical approach for WFE resources management. This study aims to search the optimal solution to WFE nexus and construct a stable water supply system for multiple stakeholders. The Shimen Reservoir and Feitsui Reservoir in northern Taiwan are chosen to conduct the joint operation of the two reservoirs for water supply. This study intends to achieve water resource allocation from the two reservoirs subject to different operating rules and restrictions of resource allocation. The multi-objectives of the joint operation aim at maximizing hydro-power synergistic gains while minimizing water supply deficiency as well as food shortages. We propose to build a multi-objective evolutionary optimization model for analyzing the hydro-power synergistic gains to suggest the most favorable solutions in terms of tradeoffs between WFE. First, this study collected data from two reservoirs and Taiwan power company. Next, we built a WFE nexus model based on system dynamics. Finally, this study optimized the joint operation of the two reservoirs and calculated the synergy of hydro-power generation. The proposed methodology can tackle the complex joint reservoir operation problems. Results can suggest a reliable policy for joint reservoir operation for creating a green economic city under the lowest risks of water supply.

  10. In-field implementation of impedance-based structural health monitoring for insulated rail joints

    NASA Astrophysics Data System (ADS)

    Albakri, Mohammad I.; Malladi, V. V. N. Sriram; Woolard, Americo G.; Tarazaga, Pablo A.

    2017-04-01

    Track defects are a major safety concern for the railroad industry. Among different track components, insulated rail joints, which are widely used for signaling purposes, are considered a weak link in the railroad track. Several joint-related defects have been identified by the railroad community, including rail wear, torque loss, and joint bar breakage. Current track inspection techniques rely on manual and visual inspection or on specially equipped testing carts, which are costly, timeconsuming, traffic disturbing, and prone to human error. To overcome the aforementioned limitations, the feasibility of utilizing impedance-based structural health monitoring for insulated rail joints is investigated in this work. For this purpose, an insulated joint, provided by Koppers Inc., is instrumented with piezoelectric transducers and assembled with 136 AREA rail plugs. The instrumented joint is then installed and tested at the Facility for Accelerated Service Testing, Transportation Technology Center Inc. The effects of environmental and operating conditions on the measured impedance signatures are investigated through a set of experiments conducted at different temperatures and loading conditions. The capabilities of impedance-based SHM to detect several joint-related damage types are also studied by introducing reversible mechanical defects to different joint components.

  11. [Case control study of fractures-dislocations of ankle joint with conservative and operative treatment].

    PubMed

    Zhang, Song-Tu; Lin, Yi-Rong; Chen, Lian-Yuan

    2010-10-01

    To compare the clinical efficacy of grade III, IV supination-eversion fractures-dislocations of ankle joint between manipulative treatment and operative treatment. From September 2007 to December 2008, the clinical data of 60 patients with grade III, IV supination-eversion fractures-dislocations of ankle joint were retrospectively analyzed. There were 32 males and 28 females, ranging in age from 18 to 70 years with an average age of 38.17 years. All patients were respectively treated with manipulative treatment (conservative group, 30 cases) and operative treatment (operative group, 30 cases). The joint function was compared with Mazur standard; the reduction and shifting of fractures were observed with X-ray; the hospitalization day and the therapeutic cost were compared between two groups. All patients were followed up with an average of 15.27 months (ranged, 6 to 25 months). In conservative group, 16 cases got excellent result in joint function, 10 good, 3 fair, 1 poor; in operative group, 20 cases got excellent result, 8 good, 2 fair, 0 poor. In conservative group in the X-ray showed 25 cases obtained excellent and good reduction, 4 fair, 1 poor; and in operative group in the X-ray showed 28 cases obtained excellent and good reduction, 2 fair, 0 poor. There was no significant difference at the joint function and X-ray film after treatment between two groups (P > 0.05). The hospital day was respectively (7.87 +/- 3.34), (17.37 +/- 4.64) d in conservative group and operative group; and the therapeutic cost was respectively (2 506.67 +/- 649.10), (11 473.33 +/- 1 564.90) yuan. There was significant difference at hospital day and therapeutic cost between two groups (P < 0.05). Conservative treatment and operative treatment can both reach a very good result in treating grade III, IV supination-eversion fractures and dislocations of ankle joint. However, conservative treatment has advantage of high safety factor, low therapeutic cost, can reduce medical costs for

  12. Post-operative bracing after ACL reconstruction has no effect on knee joint effusion. A prospective, randomized study.

    PubMed

    Lindström, Maria; Wredmark, Torsten; Wretling, Marie-Louise; Henriksson, Marketta; Felländer-Tsai, Li

    2015-12-01

    It is unclear what factors contribute to knee joint effusion after anterior cruciate ligament (ACL) injury and reconstruction. Knee homeostasis after injury and surgery is crucial for rehabilitation and knee well-being. We examined if effusion was affected by post-operative bracing, and if patients with effusion fit into a common profile. Patients were randomized to wearing or not wearing a post-operative brace for three weeks after ACL reconstruction with semitendinosus-gracilis tendons. Knee joint effusion was detected by computed tomography in 60 patients (22 women), before and three and 12 months after surgery. Joint effusion, clinical and subjective tests were analyzed. This is the first prospective, randomized study on post-operative bracing for patients with a semitendinosus-gracilis graft showed that bracing had no effect on three-months presence of joint effusion. Excessive joint effusion was present in 68% of the patients three months after surgery and was associated to prior meniscus injury (p=0.05) and higher prior Tegner activity level (p=0.006). We found a positive association between longer time from injury to surgery and joint effusion three months post-operatively (rho=0.29, p<0.05). Twelve months post-operatively, joint effusion had diminished to baseline levels. Subjective scores and activity levels were lower for women. Three-months joint effusion predicted lower final outcome scores in women. Prior meniscus injury and pre-injury Tegner activity levels are predictive significant variables for excessive knee joint effusion after ACL reconstruction. Post-operative bracing had no effect. A larger clinical cohort is needed to confirm findings of this logistic regression. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Automatic joint alignment measurements in pre- and post-operative long leg standing radiographs.

    PubMed

    Goossen, A; Weber, G M; Dries, S P M

    2012-01-01

    For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs. In a two step approach we first detect and segment any implants or other artificial objects within the image. We exploit physical characteristics and avoid prior shape information to cope with the vast amount of implant types. Subsequently, we exploit the implant delineations to adapt the initialization and adaptation phase of a dedicated bone segmentation scheme using deformable template models. Implant and bone contours are fused to derive the final joint segmentation and thus the alignment measurements. We evaluated our method on clinical long leg radiographs and compared both the initialization rate, corresponding to the number of images successfully processed by the proposed algorithm, and the accuracy of the alignment measurement. Ground truth has been generated by an experienced orthopedic surgeon. For comparison a second reader reevaluated the measurements. Experiments on two sets of 70 and 120 digital radiographs show that 92% of the joints could be processed automatically and the derived measurements of the automatic method are comparable to a human reader for pre-operative as well as post-operative images with a typical error of 0.7° and correlations of r = 0.82 to r = 0.99 with the ground truth. The proposed method allows deriving objective measures of joint alignment from clinical radiographs. Its accuracy and precision are on par with a human reader for all evaluated measurements.

  14. Operational space trajectory tracking control of robot manipulators endowed with a primary controller of synthetic joint velocity.

    PubMed

    Moreno-Valenzuela, Javier; González-Hernández, Luis

    2011-01-01

    In this paper, a new control algorithm for operational space trajectory tracking control of robot arms is introduced. The new algorithm does not require velocity measurement and is based on (1) a primary controller which incorporates an algorithm to obtain synthesized velocity from joint position measurements and (2) a secondary controller which computes the desired joint acceleration and velocity required to achieve operational space motion control. The theory of singularly perturbed systems is crucial for the analysis of the closed-loop system trajectories. In addition, the practical viability of the proposed algorithm is explored through real-time experiments in a two degrees-of-freedom horizontal planar direct-drive arm. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Welding technology transfer task/laser based weld joint tracking system for compressor girth welds

    NASA Technical Reports Server (NTRS)

    Looney, Alan

    1991-01-01

    Sensors to control and monitor welding operations are currently being developed at Marshall Space Flight Center. The laser based weld bead profiler/torch rotation sensor was modified to provide a weld joint tracking system for compressor girth welds. The tracking system features a precision laser based vision sensor, automated two-axis machine motion, and an industrial PC controller. The system benefits are elimination of weld repairs caused by joint tracking errors which reduces manufacturing costs and increases production output, simplification of tooling, and free costly manufacturing floor space.

  16. A Lossless Multichannel Bio-Signal Compression Based on Low-Complexity Joint Coding Scheme for Portable Medical Devices

    PubMed Central

    Kim, Dong-Sun; Kwon, Jin-San

    2014-01-01

    Research on real-time health systems have received great attention during recent years and the needs of high-quality personal multichannel medical signal compression for personal medical product applications are increasing. The international MPEG-4 audio lossless coding (ALS) standard supports a joint channel-coding scheme for improving compression performance of multichannel signals and it is very efficient compression method for multi-channel biosignals. However, the computational complexity of such a multichannel coding scheme is significantly greater than that of other lossless audio encoders. In this paper, we present a multichannel hardware encoder based on a low-complexity joint-coding technique and shared multiplier scheme for portable devices. A joint-coding decision method and a reference channel selection scheme are modified for a low-complexity joint coder. The proposed joint coding decision method determines the optimized joint-coding operation based on the relationship between the cross correlation of residual signals and the compression ratio. The reference channel selection is designed to select a channel for the entropy coding of the joint coding. The hardware encoder operates at a 40 MHz clock frequency and supports two-channel parallel encoding for the multichannel monitoring system. Experimental results show that the compression ratio increases by 0.06%, whereas the computational complexity decreases by 20.72% compared to the MPEG-4 ALS reference software encoder. In addition, the compression ratio increases by about 11.92%, compared to the single channel based bio-signal lossless data compressor. PMID:25237900

  17. Joint Center for Operational Analysis Journal. Volume 12, Issue 2, Summer 2010

    DTIC Science & Technology

    2010-01-01

    Peixoto. In 19X7. then-Major Keen attended Bra- zil’s Command and General Staff Course in Rio de Janeiro . Bra- zil. In 1988, then Captain Floriano...controlling DoD office). • DISTRIBUTION STATEMENT E . Distribution authorized to DoD Components only (fill in reason) (date of determination). Other... basic joint functions that integrate, synchronize, and direct joint operations, which arc: command and control, intelligence, fires, movement and

  18. 76 FR 13446 - Nittany Bald and Eagle Railroad Company-Operation Exemption-SEDA-COG Joint Rail Authority

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Eagle Railroad Company-Operation Exemption-SEDA- COG Joint Rail Authority Nittany Bald and Eagle... 0.0 and milepost 1.8 in Castanea, Clinton County, Pa. The line is owned or leased by SEDA-COG Joint Rail Authority (SEDA-COG). N&BE states that the line it proposes to operate is an extension of its...

  19. The Joint Tactical Aerial Resupply Vehicle Impact on Sustainment Operations

    DTIC Science & Technology

    2017-06-09

    Artificial Intelligence , Sustainment Operations, Rifle Company, Autonomous Aerial Resupply, Joint Tactical Autonomous Aerial Resupply System 16...Integrations and Development System AI Artificial Intelligence ARCIC Army Capabilities Integration Center ARDEC Armament Research, Development and...semi- autonomous systems, and fully autonomous systems. Autonomy of machines depends on sophisticated software, including Artificial Intelligence

  20. Diver Relative UUV Navigation for Joint Human-Robot Operations

    DTIC Science & Technology

    2013-09-01

    loop response: (10) where Kej is the gain that scales the position error to force . Substituting the measured values for ζ and ων as well as the...Underwater Vehicle; Tethered ; Hovering; Autonomous Underwater Vehicle; Joint human-robot operations; dynamic, uncertain environments 15. NUMBER OF PAGES...4   Figure 3.   The SeaBotix vLBV300 tethered AUV platform (left), and the planar vectored thruster

  1. Building a Better Trojan Horse: Emerging Army Roles in Joint Urban Operations

    DTIC Science & Technology

    2001-01-01

    Building a Better Trojan Horse : Emerging Army Roles in Joint Urban Operations A Monograph by MAJ Christopher H. Beckert Infantry, U.S. Army School...xx-xx-2000 to xx-xx-2000 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Building a Better Trojan Horse : Emerging Army Roles in Joint...TELEPHONE NUMBER International Area Code Area Code Telephone Number 703 767-9007 DSN 427-9007 2 Abstract BUILDING A BETTER TROJAN HORSE : EMERGING ARMY

  2. 76 FR 41307 - NASA Advisory Council; Space Operations Committee and Exploration Committee; Joint Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-13

    ... Operations Committee and Exploration Committee; Joint Meeting AGENCY: National Aeronautics and Space... the Space Operations Committee and Exploration Committee of the NASA Advisory Council. DATES: Tuesday.../Exploration Systems Mission Directorate Merger Update. [[Page 41308

  3. Managing Safety and Operations: The Effect of Joint Management System Practices on Safety and Operational Outcomes.

    PubMed

    Tompa, Emile; Robson, Lynda; Sarnocinska-Hart, Anna; Klassen, Robert; Shevchenko, Anton; Sharma, Sharvani; Hogg-Johnson, Sheilah; Amick, Benjamin C; Johnston, David A; Veltri, Anthony; Pagell, Mark

    2016-03-01

    The aim of this study was to determine whether management system practices directed at both occupational health and safety (OHS) and operations (joint management system [JMS] practices) result in better outcomes in both areas than in alternative practices. Separate regressions were estimated for OHS and operational outcomes using data from a survey along with administrative records on injuries and illnesses. Organizations with JMS practices had better operational and safety outcomes than organizations without these practices. They had similar OHS outcomes as those with operations-weak practices, and in some cases, better outcomes than organizations with safety-weak practices. They had similar operational outcomes as those with safety-weak practices, and better outcomes than those with operations-weak practices. Safety and operations appear complementary in organizations with JMS practices in that there is no penalty for either safety or operational outcomes.

  4. Saipan and Joint Operations

    DTIC Science & Technology

    1990-02-12

    following postwar joint education objectives for ths armed forces: Objective i: To oroduce within each component of the armed forces a general knowledge...had acquired the pradtical knowledge to establieh::thvoe Joint educational goals which are as relevant today as when they were written. ENDNOTES 1...F2:", (- 1-1 1’A I’rn ,r’ lqA ,! Vim l ;` thO? C’~~~~~~~ a m in A i h9%t ý A din r, a INi m i t z% "h e haa I.z a:wn naval. +ac! lit! es, line~i n+f

  5. Static analysis of large-scale multibody system using joint coordinates and spatial algebra operator.

    PubMed

    Omar, Mohamed A

    2014-01-01

    Initial transient oscillations inhibited in the dynamic simulations responses of multibody systems can lead to inaccurate results, unrealistic load prediction, or simulation failure. These transients could result from incompatible initial conditions, initial constraints violation, and inadequate kinematic assembly. Performing static equilibrium analysis before the dynamic simulation can eliminate these transients and lead to stable simulation. Most exiting multibody formulations determine the static equilibrium position by minimizing the system potential energy. This paper presents a new general purpose approach for solving the static equilibrium in large-scale articulated multibody. The proposed approach introduces an energy drainage mechanism based on Baumgarte constraint stabilization approach to determine the static equilibrium position. The spatial algebra operator is used to express the kinematic and dynamic equations of the closed-loop multibody system. The proposed multibody system formulation utilizes the joint coordinates and modal elastic coordinates as the system generalized coordinates. The recursive nonlinear equations of motion are formulated using the Cartesian coordinates and the joint coordinates to form an augmented set of differential algebraic equations. Then system connectivity matrix is derived from the system topological relations and used to project the Cartesian quantities into the joint subspace leading to minimum set of differential equations.

  6. Calcaneocuboid joint instability: a novel operative technique for anatomic reconstruction.

    PubMed

    Lohrer, Heinz; Arentz, Sabine

    2004-05-01

    A case history of a 13-year-old female national top-level gymnast, suffering from calcaneocuboid joint instability, is presented. The procedure was done as an anatomic repair by capsular reefing, which was augmented using a local periosteal flap. Initially, the athlete twisted her ankle. Clinical investigation revealed no sign of a lateral ankle ligament injury, but following this initial examination, recurrent giving-way of the foot occurred. She additionally felt significant but diffuse pain on the lateral side of the foot during loading in training and competition. For 2 months she was unable to run and conservative treatment failed. Diagnosis of a calcaneocuboid instability was established 4 months after the initial lesion by clinical and x-ray stress examination of the calcaneocuboid joint. Open surgery was successfully performed. Early functional posttreatment was done and the patient returned to full high-level gymnastics ability 16 weeks after surgery. Two years later, a similar injury occurred to the opposite calcaneocuboid joint and the same operative procedure again led to full sports ability.

  7. Improved decryption quality and security of a joint transform correlator-based encryption system

    NASA Astrophysics Data System (ADS)

    Vilardy, Juan M.; Millán, María S.; Pérez-Cabré, Elisabet

    2013-02-01

    Some image encryption systems based on modified double random phase encoding and joint transform correlator architecture produce low quality decrypted images and are vulnerable to a variety of attacks. In this work, we analyse the algorithm of some reported methods that optically implement the double random phase encryption in a joint transform correlator. We show that it is possible to significantly improve the quality of the decrypted image by introducing a simple nonlinear operation in the encrypted function that contains the joint power spectrum. This nonlinearity also makes the system more resistant to chosen-plaintext attacks. We additionally explore the system resistance against this type of attack when a variety of probability density functions are used to generate the two random phase masks of the encryption-decryption process. Numerical results are presented and discussed.

  8. Major Joint/Combined Operations

    DTIC Science & Technology

    2008-01-01

    Quarterly 3 (Winter 1993–1994), 74. 20 Andrew G. B. Vallance , The Air Weapon: Doctrines of Air Power Strategy and Operational Art (New York: St... Vallance , 94; and Donald L. McSwain, Air Campaign Planning for Contingency Operations (Maxwell Air Force Base, AL: Air War College, May 1989), 37. 23...require positive identification of friendly forces and positive control of aircraft. 36 Richard R. Muller, “Close Air Support: The German, British

  9. The joint operating company: an innovative approach to collaboration.

    PubMed

    Mason, S A; Seymour, D W

    1995-06-01

    Hospitals interested in horizontal integration often run into difficulties. In spite of otherwise sound business logic for two organizations to merge, there may be political, legal or financial reasons why a merger option cannot be pursued. Increasingly, enterprises are turning to a joint operating company structure as the solution to their needs. Scott A. Mason and Donald W. Seymour, partners with consulting firm National Health Advisors, explore situations where a JOC model of collaboration may be appropriate.

  10. Template-based automatic extraction of the joint space of foot bones from CT scan

    NASA Astrophysics Data System (ADS)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  11. Static Analysis of Large-Scale Multibody System Using Joint Coordinates and Spatial Algebra Operator

    PubMed Central

    Omar, Mohamed A.

    2014-01-01

    Initial transient oscillations inhibited in the dynamic simulations responses of multibody systems can lead to inaccurate results, unrealistic load prediction, or simulation failure. These transients could result from incompatible initial conditions, initial constraints violation, and inadequate kinematic assembly. Performing static equilibrium analysis before the dynamic simulation can eliminate these transients and lead to stable simulation. Most exiting multibody formulations determine the static equilibrium position by minimizing the system potential energy. This paper presents a new general purpose approach for solving the static equilibrium in large-scale articulated multibody. The proposed approach introduces an energy drainage mechanism based on Baumgarte constraint stabilization approach to determine the static equilibrium position. The spatial algebra operator is used to express the kinematic and dynamic equations of the closed-loop multibody system. The proposed multibody system formulation utilizes the joint coordinates and modal elastic coordinates as the system generalized coordinates. The recursive nonlinear equations of motion are formulated using the Cartesian coordinates and the joint coordinates to form an augmented set of differential algebraic equations. Then system connectivity matrix is derived from the system topological relations and used to project the Cartesian quantities into the joint subspace leading to minimum set of differential equations. PMID:25045732

  12. Joint Personnel Recovery Agency Joint Center for Operational Analysis and Lessons Learned Quarterly Bulletin, Volume 7, Issue 2, March 2005

    DTIC Science & Technology

    2005-03-01

    execute these dangerous and uncertain missions. iv In my recent travels in the U.S. Central Command area of operations I had the great fortune of meeting...jfcom.mil 1Joint Center for Operational Analysis and Lessons Learned (JCOA-LL) Bulletin “That others may live…to return with honor” The old Chinese ...information has to travel to meet GCC staff requirements increases the difficulty in handling and maintaining situational awareness on PR events

  13. Strategic Planning to Conduct Joint Force Network Operations: A Content Analysis of NETOPS Organizations Strategic Plans

    DTIC Science & Technology

    2007-03-01

    information dominance , Joint Network Operations (NETOPS) organizations need to be strategically aligned. As result, to enhance the capabilities-based effects of NETOPS and reduce our NETOP infrastructures susceptibility to compromise. Once the key organizations were identified, their strategic plans were analyzed using a structured content analysis framework. The results illustrated that the strategic plans were aligned with the community of interests tasking to conduct NETOPS. Further research is required into the strategic alignment beyond the strategic

  14. FE analysis of SMA-based bio-inspired bone-joint system

    NASA Astrophysics Data System (ADS)

    Yang, S.; Seelecke, S.

    2009-10-01

    This paper presents the finite element (FE) analysis of a bio-inspired bone-joint system. Motivated by the BATMAV project, which aims at the development of a micro-air-vehicle platform that implements bat-like flapping flight capabilities, we study the actuation of a typical elbow joint, using shape memory alloy (SMA) in a dual manner. Micro-scale martensitic SMA wires are used as 'metal muscles' to actuate a system of humerus, elbow joint and radius, in concert with austenitic wires, which operate as flexible joints due to their superelastic character. For the FE analysis, the humerus and radius are modeled as standard elastic beams, while the elbow joint and muscle wires use the Achenbach-Muller-Seelecke SMA model as beams and cable elements, respectively. The particular focus of the paper is on the implementation of the above SMA model in COMSOL.

  15. Expeditionary Operations Require Joint Force Capabilities in the Future Operating Environment

    DTIC Science & Technology

    2013-03-01

    endeavor, I would like to thank COL Purvis, and the professionals of JAWS Seminar 2 for letting me try to weave my thesis into almost every seminar...joint sea base, expeditionary strike group, or task force. JP 4-0, JSHIP JT&E, ’DLQ MOU Notes: The AFSB is to exploit the flexibility and...of the global commons and select sovereign territory, waters , airspace and cyberspace. 14  The combat task of overcoming the enemy’s anti-access

  16. Connecting the Force from Space: The IRIS Joint Capability Technology Demonstration

    DTIC Science & Technology

    2010-01-01

    the Joint in Joint Capability Technology Demonstration, we have two sponsors, both U.S. Strategic Command and the Defense Information Systems...Capability Technology Demonstration will provide an excellent source of data on space-based Internet Protocol net- working. Operational... Internet Routing in Space Joint Capability Technology Demonstration Operational Manager, Space and Missile Defense Battle Lab, Colorado Springs

  17. Computer-Based Radiographic Quantification of Joint Space Narrowing Progression Using Sequential Hand Radiographs: Validation Study in Rheumatoid Arthritis Patients from Multiple Institutions.

    PubMed

    Ichikawa, Shota; Kamishima, Tamotsu; Sutherland, Kenneth; Fukae, Jun; Katayama, Kou; Aoki, Yuko; Okubo, Takanobu; Okino, Taichi; Kaneda, Takahiko; Takagi, Satoshi; Tanimura, Kazuhide

    2017-10-01

    We have developed a refined computer-based method to detect joint space narrowing (JSN) progression with the joint space narrowing progression index (JSNPI) by superimposing sequential hand radiographs. The purpose of this study is to assess the validity of a computer-based method using images obtained from multiple institutions in rheumatoid arthritis (RA) patients. Sequential hand radiographs of 42 patients (37 females and 5 males) with RA from two institutions were analyzed by a computer-based method and visual scoring systems as a standard of reference. The JSNPI above the smallest detectable difference (SDD) defined JSN progression on the joint level. The sensitivity and specificity of the computer-based method for JSN progression was calculated using the SDD and a receiver operating characteristic (ROC) curve. Out of 314 metacarpophalangeal joints, 34 joints progressed based on the SDD, while 11 joints widened. Twenty-one joints progressed in the computer-based method, 11 joints in the scoring systems, and 13 joints in both methods. Based on the SDD, we found lower sensitivity and higher specificity with 54.2 and 92.8%, respectively. At the most discriminant cutoff point according to the ROC curve, the sensitivity and specificity was 70.8 and 81.7%, respectively. The proposed computer-based method provides quantitative measurement of JSN progression using sequential hand radiographs and may be a useful tool in follow-up assessment of joint damage in RA patients.

  18. 24 CFR 943.144 - What financial impact do operations of a subsidiary, affiliate, or joint venture have on a PHA?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of a subsidiary, affiliate, or joint venture have on a PHA? 943.144 Section 943.144 Housing and Urban... CONSORTIA AND JOINT VENTURES Subsidiaries, Affiliates, Joint Ventures in Public Housing § 943.144 What financial impact do operations of a subsidiary, affiliate, or joint venture have on a PHA? Income generated...

  19. Joint image encryption and compression scheme based on a new hyperchaotic system and curvelet transform

    NASA Astrophysics Data System (ADS)

    Zhang, Miao; Tong, Xiaojun

    2017-07-01

    This paper proposes a joint image encryption and compression scheme based on a new hyperchaotic system and curvelet transform. A new five-dimensional hyperchaotic system based on the Rabinovich system is presented. By means of the proposed hyperchaotic system, a new pseudorandom key stream generator is constructed. The algorithm adopts diffusion and confusion structure to perform encryption, which is based on the key stream generator and the proposed hyperchaotic system. The key sequence used for image encryption is relation to plain text. By means of the second generation curvelet transform, run-length coding, and Huffman coding, the image data are compressed. The joint operation of compression and encryption in a single process is performed. The security test results indicate the proposed methods have high security and good compression effect.

  20. Joint image encryption and compression scheme based on IWT and SPIHT

    NASA Astrophysics Data System (ADS)

    Zhang, Miao; Tong, Xiaojun

    2017-03-01

    A joint lossless image encryption and compression scheme based on integer wavelet transform (IWT) and set partitioning in hierarchical trees (SPIHT) is proposed to achieve lossless image encryption and compression simultaneously. Making use of the properties of IWT and SPIHT, encryption and compression are combined. Moreover, the proposed secure set partitioning in hierarchical trees (SSPIHT) via the addition of encryption in the SPIHT coding process has no effect on compression performance. A hyper-chaotic system, nonlinear inverse operation, Secure Hash Algorithm-256(SHA-256), and plaintext-based keystream are all used to enhance the security. The test results indicate that the proposed methods have high security and good lossless compression performance.

  1. Towards Scalable Strain Gauge-Based Joint Torque Sensors

    PubMed Central

    D’Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G.; Cuschieri, Alfred

    2017-01-01

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR). PMID:28820446

  2. Towards Scalable Strain Gauge-Based Joint Torque Sensors.

    PubMed

    Khan, Hamza; D'Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G; Cuschieri, Alfred; Semini, Claudio

    2017-08-18

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS) , the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot- MiniHyQ . This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR).

  3. Prosthetic joint infection development of an evidence-based diagnostic algorithm.

    PubMed

    Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes

    2017-03-09

    Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.

  4. Experimental Design for Evaluation of Co-extruded Refractory Metal/Nickel Base Superalloy Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ME Petrichek

    2005-12-16

    Prior to the restructuring of the Prometheus Program, the NRPCT was tasked with delivering a nuclear space reactor. Potential NRPCT nuclear space reactor designs for the Prometheus Project required dissimilar materials to be in contact with each other while operating at extreme temperatures under irradiation. As a result of the high reactor core temperatures, refractory metals were the primary candidates for many of the reactor structural and cladding components. They included the tantalum-base alloys ASTAR-811C and Ta-10W, the niobium-base alloy FS-85, and the molybdenum base alloys Moly 41-47.5 Rhenium. The refractory metals were to be joined to candidate nickel basemore » alloys such as Haynes 230, Alloy 617, or Nimonic PE 16 either within the core if the nickel-base alloys were ultimately selected to form the outer core barrel, or at a location exterior to the core if the nickel-base alloys were limited to components exterior to the core. To support the need for dissimilar metal joints in the Prometheus Project, a co-extrusion experiment was proposed. There are several potential methods for the formation of dissimilar metal joints, including explosive bonding, friction stir welding, plasma spray, inertia welding, HIP, and co-extrusion. Most of these joining methods are not viable options because they result in the immediate formation of brittle intermetallics. Upon cooling, intermetallics form in the weld fusion zone between the joined metals. Because brittle intermetallics do not form during the initial bonding process associated with HIP, co-extrusion, and explosive bonding, these three joining procedures are preferred for forming dissimilar metal joints. In reference to a Westinghouse Astronuclear Laboratory report done under a NASA sponsored program, joints that were fabricated between similar materials via explosive bonding had strengths that were directly affected by the width of the diffusion barrier. It was determined that the diffusion zone should

  5. Remote Operation of the ExoGeoLab Lander at ESTEC and Lunares Base

    NASA Astrophysics Data System (ADS)

    Lillo, A.; Foing, B. H.; Evellin, P.; Kołodziejczyk, A.; Jonglez, C.; Heinicke, C.; Harasymczuk, M.; Authier, L.; Blanc, A.; Chahla, C.; Tomic, A.; Mirino, M.; Schlacht, I.; Hettrich, S.; Pacher, T.

    2017-10-01

    The ExoGeoLab Lander is a prototype developed to demonstrate joint use of remote operation and EVA astronaut work in analogue lunar environment. It was recently deployed in the new analogue base Lunares in Poland and controlled from ESA ESTEC center.

  6. Heisenberg's error-disturbance relations: A joint measurement-based experimental test

    NASA Astrophysics Data System (ADS)

    Zhao, Yuan-Yuan; Kurzyński, Paweł; Xiang, Guo-Yong; Li, Chuan-Feng; Guo, Guang-Can

    2017-04-01

    The original Heisenberg error-disturbance relation was recently shown to be not universally valid and two different approaches to reformulate it were proposed. The first one focuses on how the error and disturbance of two observables A and B depend on a particular quantum state. The second one asks how a joint measurement of A and B affects their eigenstates. Previous experiments focused on the first approach. Here we focus on the second one. First, we propose and implement an extendible method of quantum-walk-based joint measurements of noisy Pauli operators to test the error-disturbance relation for qubits introduced in the work of Busch et al. [Phys. Rev. A 89, 012129 (2014), 10.1103/PhysRevA.89.012129], where the polarization of the single photon, corresponding to a walker's auxiliary degree of freedom that is commonly known as a coin, undergoes a position- and time-dependent evolution. Then we formulate and experimentally test a universally valid state-dependent relation for three mutually unbiased observables. We therefore establish a method of testing error-disturbance relations.

  7. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

    PubMed

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-01

    Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

  8. Theater Logistics Management: A Case for a Joint Distribution Solution

    DTIC Science & Technology

    2008-03-15

    Multinational (JIIM) operations necessitate creating joint-multinational-based distribution management centers which effectively manage materiel...in the world. However, as the operation continued, the inherent weakness of the intra-theater logistical distribution management link became clear...compounded the distribution management problem. The common thread between each of the noted GAO failures is the lack of a defined joint, theater

  9. Method and apparatus for preloading a joint by remotely operable means

    NASA Technical Reports Server (NTRS)

    Kahn, Jon B. (Inventor)

    1993-01-01

    The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.

  10. Method and apparatus for preloading a joint by remotely operable means

    NASA Technical Reports Server (NTRS)

    Shelton, Robert O. (Inventor)

    1992-01-01

    The invention is a method and apparatus for joining structures, an active structure and a passive structure, and imposing a tensile pre-load on the joint by a remotely operable mechanism comprising a heat contractible joining element. The method and apparatus include mounting on the structure, a probe shaft of material which is transformable from an expanded length to a contracted length when heated to a specific temperature range. The shaft is provided with a probe head which is receivable in a receptacle opening formed in the passive structure, when the active structure is moved into engagement therewith by an appropriate manipulator mechanism. A latching system mounted on the structure adjacent to the receptacle opening captures the probe head, when the probe head is inserted a predetermined amount. A heating coil on the shaft is energizable by remote control for heating the shaft to a temperature range which transforms the shaft to its contracted length, whereby a latching shoulder thereof engages latching elements of the latching system and imposes a tensile preload on the structural joint. Provision is also made for manually adjusting the probe head on the shaft to allow for manual detachment of the structures or manual preloading of the structural joint.

  11. The Secret of Future Defeat: The Evolution of US Joint and Army Doctrine 1993-2006 and the Flawed Conception of Stability Operations

    DTIC Science & Technology

    2007-05-24

    The Secret of Future Defeat: the Evolution of US Joint and Army Doctrine 1993-2006 and the Flawed Conception of Stability Operations A...4. TITLE AND SUBTITLE The Secret of Future Defeat: the Evolution of US Joint and 5a. CONTRACT NUMBER Army Doctrine 1993-2006 and the Flawed... The Secret of Future Defeat: the Evolution of US Joint and Army Doctrine 1993-2006 and the Flawed Conception of Stability Operations Approved by

  12. Safety assessment of Cracked K-joint Structure Based on Fracture Mechanics

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Pengyu, Yan; Jianwei, Du; Fuhai, Cai

    2017-05-01

    The K-joint is the main bearing structure of lattice jib crane. During frequent operation of the crane, surface cracks often occur at its weld toe, and then continue to expand until failure. The safety of the weak structure K-joint of the crane jib can be evaluated by BS7910 failure assessment standard in order to improve its utilization. The finite element model of K-joint structure with cracks is established, and its mechanical properties is analyzed by ABAQUS software, the results show that the crack depth has a great influence on the bearing capacity of the structure compared with the crack length. It is assumed that the K-joint with the semi-elliptical surface crack under the action of the tension propagate stably under the condition that the c/a (ratio of short axis to long axis of ellipse) is about 0.3. The safety assessment of K-joint with different lengths crack is presented according to the 2A failure assessment diagram of BS7910, and the critical crack of K-joint under different loads can be obtained.

  13. The effect of mindfulness training prior to total joint arthroplasty on post-operative pain and physical function: study protocol for a randomised controlled trial.

    PubMed

    Dowsey, Michelle M; Castle, David J; Knowles, Simon R; Monshat, Kaveh; Salzberg, Michael R; Choong, Peter F M

    2014-06-05

    Osteoarthritis is a leading cause of disability in developed nations. In Australia it afflicts 16.5% of the adult population. Total joint arthroplasty is considered the treatment of choice for end stage osteoarthritis. The number of total joint arthroplasties undertaken in Australia has doubled over the last decade (more than 80,000 procedures in 2011). The incidence of pre-operative psychological distress in this group of patients is reported between 30% and 60% and pre-operative psychological distress is associated with poorer pain and functional outcomes after surgery. This study will use a mindfulness-based psychological intervention to enhance outcomes in people undergoing total joint arthroplasty and, in addition, will test hypotheses about coping with chronic illness in an aged population. This study is the first of its kind and will provide a greater understanding of the role of a mental health enhancement program on the physical recovery of total joint arthroplasty patients. One hundred and fifty people with end-stage arthritis on the waiting list for total hip or knee arthroplasty will be recruited and randomly allocated to one of two groups using computer-generated block randomisation. A randomised controlled trial adhering to CONSORT guidelines will evaluate the efficacy of a mindfulness training program (weekly group-based classes in mindfulness practice, 2 ½ hours, for 8 weeks plus a 7-hour Saturday session in Week 6) prior to total joint arthroplasty, compared to a "standard care" group who will undergo routine total joint arthroplasty. Primary outcomes will be evaluated by a blinded examiner at baseline, 3 and 12 months post-surgery, using a validated self-reported pain and physical function scale. Secondary outcomes will include i) a range of validated measures of psychological wellbeing and ii) health economic analysis. All analyses will be conducted on an intention to treat basis using linear regression models. Health economic modelling will

  14. Self-aligning exoskeleton hip joint: Kinematic design with five revolute, three prismatic and one ball joint.

    PubMed

    Beil, Jonas; Marquardt, Charlotte; Asfour, Tamim

    2017-07-01

    Kinematic compatibility is of paramount importance in wearable robotic and exoskeleton design. Misalignments between exoskeletons and anatomical joints of the human body result in interaction forces which make wearing the exoskeleton uncomfortable and even dangerous for the human. In this paper we present a kinematically compatible design of an exoskeleton hip to reduce kinematic incompatibilities, so called macro- and micro-misalignments, between the human's and exoskeleton's joint axes, which are caused by inter-subject variability and articulation. The resulting design consists of five revolute, three prismatic and one ball joint. Design parameters such as range of motion and joint velocities are calculated based on the analysis of human motion data acquired by motion capture systems. We show that the resulting design is capable of self-aligning to the human hip joint in all three anatomical planes during operation and can be adapted along the dorsoventral and mediolateral axis prior to operation. Calculation of the forward kinematics and FEM-simulation considering kinematic and musculoskeletal constraints proved sufficient mobility and stiffness of the system regarding the range of motion, angular velocity and torque admissibility needed to provide 50 % assistance for an 80 kg person.

  15. Developing Joint Information Operations Warriors

    DTIC Science & Technology

    2006-04-13

    the spectrum of conflict more than ever before. Information dominance has always been important, but the speed and methods at which it can be sent... information dominance . The analysis begins with a quick review of joint IO doctrine, Service approaches to IO, and IO personnel management. Next, IO

  16. DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kartashov,V.V.; Pratt,W.; Romanov, Y.A.

    The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Departmentmore » of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.« less

  17. Joint multifractal analysis based on wavelet leaders

    NASA Astrophysics Data System (ADS)

    Jiang, Zhi-Qiang; Yang, Yan-Hong; Wang, Gang-Jin; Zhou, Wei-Xing

    2017-12-01

    Mutually interacting components form complex systems and these components usually have long-range cross-correlated outputs. Using wavelet leaders, we propose a method for characterizing the joint multifractal nature of these long-range cross correlations; we call this method joint multifractal analysis based on wavelet leaders (MF-X-WL). We test the validity of the MF-X-WL method by performing extensive numerical experiments on dual binomial measures with multifractal cross correlations and bivariate fractional Brownian motions (bFBMs) with monofractal cross correlations. Both experiments indicate that MF-X-WL is capable of detecting cross correlations in synthetic data with acceptable estimating errors. We also apply the MF-X-WL method to pairs of series from financial markets (returns and volatilities) and online worlds (online numbers of different genders and different societies) and determine intriguing joint multifractal behavior.

  18. Joint High Speed Vessel (JHSV) Follow on Operational Test and Evaluation (FOT and E) Report

    DTIC Science & Technology

    2015-09-21

    Speed Vessel (JHSV) ship class. The events covered in this testing were not performed during the Initial Operational Test and Evaluation ( IOT &E...support boats since launch of these type boats was completed in IOT &E. 1 “Initial Operational Test...and Evaluation ( IOT &E) with Live Fire Test and Evaluation (LFT&E) on Joint High Speed Vessel (JHSV),” DOT&E, July 17, 2014. 2 MLP (CCS) is a heavy

  19. Joint preserving surgery versus arthrodesis in operative treatment of patients with neuromuscular polyneuropathy: questionnaire assessment.

    PubMed

    Napiontek, Marek; Pietrzak, Krzysztof

    2015-02-01

    The purpose of the paper was to present the results of surgical treatment of foot deformities in peripheral neuropathies using bone procedures: both joint preserving and with joint arthrodesis. The study included 26 patients, 14 males and 12 females (43 feet). The age of the patients at surgery ranged from 5 to 55 years (average 23 years). The follow-up ranged from 0.5 to 15 years (average 4.3 years). Seventeen patients presented Charcot-Marie-Tooth disease, three Friedreich's ataxia and six peripheral motor and sensory neuropathies of undetermined nature. Sixteen patients had bilateral procedures. Four patients had to be re-operated during the follow-up. The patients were divided into four groups depending on the age and the surgical technique applied. The groups I and II (9 children, 17 feet) included patients with growth plate still present in the foot just before surgery. In the groups III and IV (17 adults, 26 feet), bone growth was completed. The assessment of all patients based on a modified AOFAS scale ranged from 44 to 105 points (mean 83.7; SD 17.5). The assessment on the subjective scale ranged from 3 to 10 points (mean 7.4; SD 2.1). The assessment of quality of life on the WOMAC scale ranged from 0 to 41 points (mean 15.7; SD 13.2). All patients stated that they would decide to undergo the treatment again. For groups I and II, joint preserving surgeries gave better results; however, the results could not be statistically confirmed. The results for the groups III and IV were inconclusive as to which surgical techniques should be preferred, arthrodesis or joint preserving. The results show that none of the surgical techniques used for correction of foot deformities in motor-sensory polyneuropathies seems to be preferable.

  20. Joint Command Decision Support System

    DTIC Science & Technology

    2011-06-01

    2010 Olympics and Paralympics games , about a hundred agencies and organizations were involved with the safety and security of the games . Accordingly...Joint Task Force Games (JTFG) staff members were augmented with other Command Staff from Canada Command and Canadian Operational Support Command...CANOSCOM) to create an operational HQ. The scenario used for demonstration was based on fictitious Olympic Games (Breton and Guitouni 2008). The scenario

  1. Arthroscopic treatment of acute acromioclavicular joint dislocation by coracoclavicular ligament augmentation.

    PubMed

    Liu, Xudong; Huangfu, Xiaoqiao; Zhao, Jinzhong

    2015-05-01

    Coracoclavicular (CC) ligament augmentation has been a method to treat acromioclavicular (AC) joint dislocation in recent years. The purpose of this paper is to describe our arthroscopic CC ligament augmentation technique in treating type III and V acute AC joint dislocations and to report the early clinical and radiological results. From 2010 to 2011, twelve patients suffering from acute type III or V AC joint dislocations were arthroscopically treated in our department, by CC ligament augmentation after AC joint reduction. The post-operative outcomes were assessed through physical examination, radiographic examination and the Constant-Murley Shoulder Score. All patients post-operatively experienced anatomical reduction in their AC joint dislocation. No intraoperative complications occurred. At a mean follow-up at 24 months (ranging from 18 to 32 months), the mean Constant-Murley Shoulder Score significantly improved from 24.3 pre-operatively to 91.1 post-operatively. No neurovascular complications or secondary degenerative changes of the AC joint were detected in any of the patients. In one case, a second dislocation occurred 1 month post-operation because the patient had had another traumatic injury. This patient accepted a revision operation, but his AC joint eventually fixated into a subluxated position after his second injury. Based on the resultant successful repair in all cases, the arthroscopic CC ligament augmentation method has thus far proven to be a safe and reliable technique for treatment of acute type III or V AC joint dislocation. The arthroscopic CC ligament augmentation with a flip button/polyethylene belt repair is an efficient method to treat acute type III and V AC joint dislocations which should be popularized. IV.

  2. [Operative treatment and curative effects of the deltoid ligament injuries of the ankle joint].

    PubMed

    Cong, Pei-Jun; Liu, Bai-Hong; Wang, Ji-Ping; Qiao, Yong-Ping

    2009-12-01

    To explore the operative methods and curative effects of the deltoid ligament injuries. From 2002 to 2008, all 61 patients with ankle fractures complicated with deltoid ligament injuries were treated with open reduction and firm internal fixation. Among the patients, 39 patients were male and 22 patients were female, ranging in age from 14 to 71 years, with an average of 41 years. During the operation, the deltoid ligament was reconstructed to restore the medial and lateral stability of ankle joint. All the patients were followed up ranged from 5 to 30 months, with an average of 17 months. Fifty-nine patients had incision healed at the first stage; 2 patients had superficial infections at lateral malleolus, and healed at the 3rd week after changing dressings. The incisions at the internal medial malleolus were all healed at the first stage. According to Qi evaluation criteria, 35 patients got an excellent result, 13 good and 13 fair. The deltoid ligament should be treated properly in the treatment of ankle joint fractures when open reduction and firm internal fixation were emphasized.

  3. Joint Spacelab-J (SL-J) Activities at the Huntsville Operations Support Center (HOSC) Spacelab

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The science laboratory, Spacelab-J (SL-J), flown aboard the STS-47 flight was a joint venture between NASA and the National Space Development Agency of Japan (NASDA) utilizing a manned Spacelab module. The mission conducted 24 materials science and 20 life science experiments, of which 35 were sponsored by NASDA, 7 by NASA, and two collaborative efforts. Materials science investigations covered such fields as biotechnology, electronic materials, fluid dynamics and transport phenomena, glasses and ceramics, metals and alloys, and acceleration measurements. Life sciences included experiments on human health, cell separation and biology, developmental biology, animal and human physiology and behavior, space radiation, and biological rhythms. Test subjects included the crew, Japanese koi fish (carp), cultured animal and plant cells, chicken embryos, fruit flies, fungi and plant seeds, and frogs and frog eggs. Featured together in joint ground activities during the SL-J mission are NASA/NASDA personnel at the Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at Marshall Space Flight Center (MSFC).

  4. Stochastic optimal operation of reservoirs based on copula functions

    NASA Astrophysics Data System (ADS)

    Lei, Xiao-hui; Tan, Qiao-feng; Wang, Xu; Wang, Hao; Wen, Xin; Wang, Chao; Zhang, Jing-wen

    2018-02-01

    Stochastic dynamic programming (SDP) has been widely used to derive operating policies for reservoirs considering streamflow uncertainties. In SDP, there is a need to calculate the transition probability matrix more accurately and efficiently in order to improve the economic benefit of reservoir operation. In this study, we proposed a stochastic optimization model for hydropower generation reservoirs, in which 1) the transition probability matrix was calculated based on copula functions; and 2) the value function of the last period was calculated by stepwise iteration. Firstly, the marginal distribution of stochastic inflow in each period was built and the joint distributions of adjacent periods were obtained using the three members of the Archimedean copulas, based on which the conditional probability formula was derived. Then, the value in the last period was calculated by a simple recursive equation with the proposed stepwise iteration method and the value function was fitted with a linear regression model. These improvements were incorporated into the classic SDP and applied to the case study in Ertan reservoir, China. The results show that the transition probability matrix can be more easily and accurately obtained by the proposed copula function based method than conventional methods based on the observed or synthetic streamflow series, and the reservoir operation benefit can also be increased.

  5. Comparison of the effects of forefoot joint-preserving arthroplasty and resection-replacement arthroplasty on walking plantar pressure distribution and patient-based outcomes in patients with rheumatoid arthritis.

    PubMed

    Ebina, Kosuke; Hirao, Makoto; Takagi, Keishi; Ueno, Sachi; Morimoto, Tokimitsu; Matsuoka, Hozo; Kitaguchi, Kazuma; Iwahashi, Toru; Hashimoto, Jun; Yoshikawa, Hideki

    2017-01-01

    The purpose of this retrospective study is to clarify the difference in plantar pressure distribution during walking and related patient-based outcomes between forefoot joint-preserving arthroplasty and resection-replacement arthroplasty in patients with rheumatoid arthritis (RA). Four groups of patients were recruited. Group1 included 22 feet of 11 healthy controls (age 48.6 years), Group2 included 36 feet of 28 RA patients with deformed non-operated feet (age 64.8 years, Disease activity score assessing 28 joints with CRP [DAS28-CRP] 2.3), Group3 included 27 feet of 20 RA patients with metatarsal head resection-replacement arthroplasty (age 60.7 years, post-operative duration 5.6 years, DAS28-CRP 2.4), and Group4 included 34 feet of 29 RA patients with metatarsophalangeal (MTP) joint-preserving arthroplasty (age 64.6 years, post-operative duration 3.2 years, DAS28-CRP 2.3). Patients were cross-sectionally examined by F-SCAN II to evaluate walking plantar pressure, and the self-administered foot evaluation questionnaire (SAFE-Q). Twenty joint-preserving arthroplasty feet were longitudinally examined at both pre- and post-operation. In the 1st MTP joint, Group4 showed higher pressure distribution (13.7%) than Group2 (8.0%) and Group3 (6.7%) (P<0.001). In the 2nd-3rd MTP joint, Group4 showed lower pressure distribution (9.0%) than Group2 (14.5%) (P<0.001) and Group3 (11.5%) (P<0.05). On longitudinal analysis, Group4 showed increased 1st MTP joint pressure (8.5% vs. 14.7%; P<0.001) and decreased 2nd-3rd MTP joint pressure (15.2% vs. 10.7%; P<0.01) distribution. In the SAFE-Q subscale scores, Group4 showed higher scores than Group3 in pain and pain-related scores (84.1 vs. 71.7; P<0.01) and in shoe-related scores (62.5 vs. 43.1; P<0.01). Joint-preserving arthroplasty resulted in higher 1st MTP joint and lower 2nd-3rd MTP joint pressures than resection-replacement arthroplasty, which were associated with better patient-based outcomes.

  6. Temporo mandibular joint ankylosis.

    PubMed

    Vasconcelos, Belmiro Cavalcanti do Egito; Porto, Gabriela Granja; Bessa-Nogueira, Ricardo Viana

    2008-01-01

    Ankylosis may be defined as joint surfaces fusion. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high recurrence rate. The aim of this study is to report six cases treated by joint reconstruction, evaluate the results of these surgeries and review the literature. The sample in this retrospective study was obtained from the records of the university hospital, patients who had to undergo ankylosis treatment by alloplastic or autogenous graft between March 2001 and October 2005. Pre - and post-operative assessment included a throughout history and physical examination to determine the cause of ankylosis, the Maximum mouth opening (MMO), etiology and type of ankylosis, recurrence rate and presence of facial nerve paralysis. The mean MMO in the pre-operative period was 9.6 mm (0 mm to 17 mm) and in the post-operative period it was of 31.33 mm (14 mm to 41 mm), there was no facial nerve paralysis and there was recurrence in just one case. The joint reconstruction with alloplastic or autogenous grafts for the ankylosis treatment proved to be efficient in relation to the post-operative MMO, recurrence and joint function.

  7. Joint Task Force-Bravo

    Science.gov Websites

    Air Base Squadron Joint Security Forces Medical Element (MEDEL) JSB / ARFOR En Español Noticias Hojas to provide medical care in Waspam Call to Duty - Senior Airman Nicholas Carssow Operations Support JTF-Bravo partners with Nicaragua to provide medical care in Waspam JTF-Bravo partners with Nicaragua

  8. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    PubMed

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial

  9. 28 CFR 48.4 - Application for approval of joint newspaper operating arrangement entered into after July 24, 1970.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... newspaper operating arrangement entered into after July 24, 1970. 48.4 Section 48.4 Judicial Administration DEPARTMENT OF JUSTICE (CONTINUED) NEWSPAPER PRESERVATION ACT § 48.4 Application for approval of joint newspaper operating arrangement entered into after July 24, 1970. (a) Persons desiring to obtain the...

  10. Human joint motion estimation for electromyography (EMG)-based dynamic motion control.

    PubMed

    Zhang, Qin; Hosoda, Ryo; Venture, Gentiane

    2013-01-01

    This study aims to investigate a joint motion estimation method from Electromyography (EMG) signals during dynamic movement. In most EMG-based humanoid or prosthetics control systems, EMG features were directly or indirectly used to trigger intended motions. However, both physiological and nonphysiological factors can influence EMG characteristics during dynamic movements, resulting in subject-specific, non-stationary and crosstalk problems. Particularly, when motion velocity and/or joint torque are not constrained, joint motion estimation from EMG signals are more challenging. In this paper, we propose a joint motion estimation method based on muscle activation recorded from a pair of agonist and antagonist muscles of the joint. A linear state-space model with multi input single output is proposed to map the muscle activity to joint motion. An adaptive estimation method is proposed to train the model. The estimation performance is evaluated in performing a single elbow flexion-extension movement in two subjects. All the results in two subjects at two load levels indicate the feasibility and suitability of the proposed method in joint motion estimation. The estimation root-mean-square error is within 8.3% ∼ 10.6%, which is lower than that being reported in several previous studies. Moreover, this method is able to overcome subject-specific problem and compensate non-stationary EMG properties.

  11. A Thumb Carpometacarpal Joint Coordinate System Based on Articular Surface Geometry

    PubMed Central

    Halilaj, Eni; Rainbow, Michael J.; Got, Christopher; Moore, Douglas C.; Crisco, Joseph J.

    2013-01-01

    The thumb carpometacarpal (CMC) joint is a saddle-shaped articulation whose in vivo kinematics can be explored more accurately with computed tomography (CT) imaging methods than with previously used skin-based marker systems. These CT-based methods permit a detailed analysis of the morphology of the joint, and thus the prominent saddle-shaped geometry can be used to define a coordinate system that is inherently aligned with the primary directions of motion at the joint. The purpose of this study was to develop a CMC joint coordinate systems that is based on the computed principal directions of curvature on the trapezium and the first metacarpal. We evaluated the new coordinate system using bone surface models segmented from the CT scans of twenty-four healthy subjects. An analysis of sensitivity to the manual selection of articular surfaces resulted in mean orientation differences of 0.7±0.7° and mean location differences of 0.2±0.1mm. Inter-subject variability, which mostly emanates from anatomical differences, was evaluated with whole bone registration and resulted in mean orientation differences of 3.1±2.7° and mean location differences of 0.9±0.5mm. The proposed joint coordinate system addresses concerns of repeatability associated with bony landmark identification and provides a robust platform for describing the complex kinematics of the CMC joint. PMID:23357698

  12. NEWS RELEASE - Agencies Agree to Joint Regulatory Framework for Processing Applications for Surface Coal Mining Operations

    EPA Pesticide Factsheets

    News release from February 10, 2005 announcing a memorandum of understanding (MOU) that offers a joint framework to improve permit application procedures for surface coal mining operations that place dredged or fill material in waters of the United States.

  13. Finger jointing green southern yellow pine with a soy-based adhesive

    Treesearch

    Philip H. Steele; Roland E. Kreibicha; Petrus J. Steynberg; Richard W. Hemingway

    1998-01-01

    The authors present results of laboratory tests for a soy-based adhesive to bond southern yellow pine using the finger-jointing method. There was some reason to suspect that finger jointing of southern yellow pine (SYP) with the honeymoon system using soy-based adhesive might prove more difficult than for western species. The Wood Handbook classes western species in...

  14. Command and Control of Joint Air Operations. Some Lessons Learned from Four Case Studies of an Enduring Issue

    DTIC Science & Technology

    1991-01-01

    New Zealand Air Force.4 To further complicate matters, General Douglas MacArthur, as Commander Southwest Pacific Area, and the adjoining theater...Army, Marine, and New Zealand officers and the top job was rotated fairly regularly among the services.10 By early 1943 a truly joint staff had...in joint air operations. 2C. Kenneth Allard, Command, Control, and the Common Defense, Yale University Press, New Haven, 1990. The authors strongly

  15. Operator based integration of information in multimodal radiological search mission with applications to anomaly detection

    NASA Astrophysics Data System (ADS)

    Benedetto, J.; Cloninger, A.; Czaja, W.; Doster, T.; Kochersberger, K.; Manning, B.; McCullough, T.; McLane, M.

    2014-05-01

    Successful performance of radiological search mission is dependent on effective utilization of mixture of signals. Examples of modalities include, e.g., EO imagery and gamma radiation data, or radiation data collected during multiple events. In addition, elevation data or spatial proximity can be used to enhance the performance of acquisition systems. State of the art techniques in processing and exploitation of complex information manifolds rely on diffusion operators. Our approach involves machine learning techniques based on analysis of joint data- dependent graphs and their associated diffusion kernels. Then, the significant eigenvectors of the derived fused graph Laplace and Schroedinger operators form the new representation, which provides integrated features from the heterogeneous input data. The families of data-dependent Laplace and Schroedinger operators on joint data graphs, shall be integrated by means of appropriately designed fusion metrics. These fused representations are used for target and anomaly detection.

  16. A complexity science-based framework for global joint operations analysis to support force projection: LDRD Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Craig R.

    2015-01-01

    The military is undergoing a significant transformation as it modernizes for the information age and adapts to address an emerging asymmetric threat beyond traditional cold war era adversaries. Techniques such as traditional large-scale, joint services war gaming analysis are no longer adequate to support program evaluation activities and mission planning analysis at the enterprise level because the operating environment is evolving too quickly. New analytical capabilities are necessary to address modernization of the Department of Defense (DoD) enterprise. This presents significant opportunity to Sandia in supporting the nation at this transformational enterprise scale. Although Sandia has significant experience with engineeringmore » system of systems (SoS) and Complex Adaptive System of Systems (CASoS), significant fundamental research is required to develop modeling, simulation and analysis capabilities at the enterprise scale. This report documents an enterprise modeling framework which will enable senior level decision makers to better understand their enterprise and required future investments.« less

  17. STS payloads mission control study continuation phase A-1. Volume 2-C, task 3: Identification of joint activities and estimation of resources in preparation for joint flight operations

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Payload mission control concepts are developed for real time flight operations of STS. Flight planning, training, simulations, and other flight preparations are included. Payload activities for the preflight phase, activity sequences and organizational allocations, and traffic and experience factors to establish composite man-loading for joint STS payload activities are identified for flight operations from 1980 to 1985.

  18. Blood management and transfusion strategies in 600 patients undergoing total joint arthroplasty: an analysis of pre-operative autologous blood donation.

    PubMed

    Perazzo, Paolo; Viganò, Marco; De Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio

    2013-07-01

    Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient's physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures.

  19. Optimised robot-based system for the exploration of elastic joint properties.

    PubMed

    Frey, M; Burgkart, R; Regenfelder, F; Riener, R

    2004-09-01

    Numerous publications provide measured biomechanical data relating to synovial joints. However, in general, they do not reflect the non-linear elastic joint properties in detail or do not consider all degrees of freedom (DOF), or the quantity of data is sparse. To perform more comprehensive, extended measurements of elastic joint properties, an optimised robot-based approach was developed. The basis was an industrial, high-precision robot that was capable of applying loads to the joint and measuring the joint displacement in 6 DOF. The system was equipped with novel, custom-made control hardware. In contrast to the commonly used sampling rates that are below 100 Hz, a rate of 4 kHz was realised for each DOF. This made it possible to implement advanced, highly dynamic, quasi-continuous closed-loop controllers. Thus oscillations of the robot were avoided, and measurements were speeded up. The stiffness of the entire system was greater than 44 kNm(-1) and 22 Nm deg(-1), and the maximum difference between two successive measurements was less than 0.5 deg. A sophisticated CT-based referencing routine facilitated the matching of kinematic data with the individual anatomy of the tested joint. The detailed detection of the elastic varus-valgus properties of a human knee joint is described, and the need for high spatial resolution is demonstrated.

  20. Multi Sector Planning Tools for Trajectory-Based Operations

    NASA Technical Reports Server (NTRS)

    Prevot, Thomas; Mainini, Matthew; Brasil, Connie

    2010-01-01

    This paper discusses a suite of multi sector planning tools for trajectory-based operations that were developed and evaluated in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center. The toolset included tools for traffic load and complexity assessment as well as trajectory planning and coordination. The situation assessment tools included an integrated suite of interactive traffic displays, load tables, load graphs, and dynamic aircraft filters. The planning toolset allowed for single and multi aircraft trajectory planning and data communication-based coordination of trajectories between operators. Also newly introduced was a real-time computation of sector complexity into the toolset that operators could use in lieu of aircraft count to better estimate and manage sector workload, especially in situations with convective weather. The tools were used during a joint NASA/FAA multi sector planner simulation in the AOL in 2009 that had multiple objectives with the assessment of the effectiveness of the tools being one of them. Current air traffic control operators who were experienced as area supervisors and traffic management coordinators used the tools throughout the simulation and provided their usefulness and usability ratings in post simulation questionnaires. This paper presents these subjective assessments as well as the actual usage data that was collected during the simulation. The toolset was rated very useful and usable overall. Many elements received high scores by the operators and were used frequently and successfully. Other functions were not used at all, but various requests for new functions and capabilities were received that could be added to the toolset.

  1. [Staple fixation for the treatment of hamate metacarpal joint injury].

    PubMed

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  2. Joint road safety operations in tunnels and open roads

    NASA Astrophysics Data System (ADS)

    Adesiyun, Adewole; Avenoso, Antonio; Dionelis, Kallistratos; Cela, Liljana; Nicodème, Christophe; Goger, Thierry; Polidori, Carlo

    2017-09-01

    The objective of the ECOROADS project is to overcome the barrier established by the formal interpretation of the two Directives 2008/96/EC and 2004/54/EC, which in practice do not allow the same Road Safety Audits/Inspections to be performed inside tunnels. The projects aims at the establishment of a common enhanced approach to road infrastructure and tunnel safety management by using the concepts and criteria of the Directive 2008/96/CE on road infrastructure safety management and the results of related European Commission (EC) funded projects. ECOROADS has already implemented an analysis of national practices regarding Road Safety Inspections (RSI), two Workshops with the stakeholders, and an exchange of best practices between European tunnel experts and road safety professionals, which led to the definition of common agreed safety procedures. In the second phase of the project, different groups of experts and observers applied the above common procedures by inspecting five European road sections featuring both open roads and tunnels in Belgium, Albania, Germany, Serbia and Former Yugoslav Republic of Macedonia. This paper shows the feedback of the 5 joint safety operations and how they are being used for a set of - recommendations and guidelines for the application of the RSA and RSI concepts within the tunnel safety operations.

  3. Application of finite element analysis in pre-operative planning for deformity correction of abnormal hip joints--a case series.

    PubMed

    Rhyu, K H; Kim, Y H; Park, W M; Kim, K; Cho, T-J; Choi, I H

    2011-09-01

    In experimental and clinical research, it is difficult to directly measure responses in the human body, such as contact pressure and stress in a joint, but finite element analysis (FEA) enables the examination of in vivo responses by contact analysis. Hence, FEA is useful for pre-operative planning prior to orthopaedic surgeries, in order to gain insight into which surgical options will result in the best outcome. The present study develops a numerical simulation technique based on FEA to predict the surgical outcomes of osteotomy methods for the treatment of slipped capital femoral epiphyses. The correlation of biomechanical parameters including contact pressure and stress, for moderate and severe cases, is investigated. For severe slips, a base-of-neck osteotomy is thought to be the most reliable and effective surgical treatment, while any osteotomy may produce dramatic improvement for moderate slips. This technology of pre-operative planning using FEA can provide information regarding biomechanical parameters that might facilitate the selection of optimal osteotomy methods and corresponding surgical options.

  4. Reliability of a smartphone-based goniometer for knee joint goniometry.

    PubMed

    Ferriero, Giorgio; Vercelli, Stefano; Sartorio, Francesco; Muñoz Lasa, Susana; Ilieva, Elena; Brigatti, Elisa; Ruella, Carolina; Foti, Calogero

    2013-06-01

    The aim of this study was to assess the reliability of a smartphone-based application developed for photographic-based goniometry, DrGoniometer (DrG), by comparing its measurement of the knee joint angle with that made by a universal goniometer (UG). Joint goniometry is a common mode of clinical assessment used in many disciplines, in particular in rehabilitation. One validated method is photographic-based goniometry, but the procedure is usually complex: the image has to be downloaded from the camera to a computer and then edited using dedicated software. This disadvantage may be overcome by the new generation of mobile phones (smartphones) that have computer-like functionality and an integrated digital camera. This validation study was carried out under two different controlled conditions: (i) with the participant to measure in a fixed position and (ii) with a battery of pictures to assess. In the first part, four raters performed repeated measurements with DrG and UG at different knee joint angles. Then, 10 other raters measured the knee at different flexion angles ranging 20-145° on a battery of 35 pictures taken in a clinical setting. The results showed that inter-rater and intra-rater correlations were always more than 0.958. Agreement with the UG showed a width of 18.2° [95% limits of agreement (LoA)=-7.5/+10.7°] and 14.1° (LoA=-6.6/+7.5°). In conclusion, DrG seems to be a reliable method for measuring knee joint angle. This mHealth application can be an alternative/additional method of goniometry, easier to use than other photographic-based goniometric assessments. Further studies are required to assess its reliability for the measurement of other joints.

  5. Blood management and transfusion strategies in 600 patients undergoing total joint arthroplasty: an analysis of pre-operative autologous blood donation

    PubMed Central

    Perazzo, Paolo; Viganò, Marco; de Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio

    2013-01-01

    Background Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. Materials and methods The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Results Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. Discussion The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient’s physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures. PMID:23736922

  6. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    PubMed

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Multi-Scale Computational Modeling of Ni-Base Superalloy Brazed Joints for Gas Turbine Applications

    NASA Astrophysics Data System (ADS)

    Riggs, Bryan

    Brazed joints are commonly used in the manufacture and repair of aerospace components including high temperature gas turbine components made of Ni-base superalloys. For such critical applications, it is becoming increasingly important to account for the mechanical strength and reliability of the brazed joint. However, material properties of brazed joints are not readily available and methods for evaluating joint strength such as those listed in AWS C3.2 have inherent challenges compared with testing bulk materials. In addition, joint strength can be strongly influenced by the degree of interaction between the filler metal (FM) and the base metal (BM), the joint design, and presence of flaws or defects. As a result, there is interest in the development of a multi-scale computational model to predict the overall mechanical behavior and fitness-for-service of brazed joints. Therefore, the aim of this investigation was to generate data and methodology to support such a model for Ni-base superalloy brazed joints with conventional Ni-Cr-B based FMs. Based on a review of the technical literature a multi-scale modeling approach was proposed to predict the overall performance of brazed joints by relating mechanical properties to the brazed joint microstructure. This approach incorporates metallurgical characterization, thermodynamic/kinetic simulations, mechanical testing, fracture mechanics and finite element analysis (FEA) modeling to estimate joint properties based on the initial BM/FM composition and brazing process parameters. Experimental work was carried out in each of these areas to validate the multi-scale approach and develop improved techniques for quantifying brazed joint properties. Two Ni-base superalloys often used in gas turbine applications, Inconel 718 and CMSX-4, were selected for study and vacuum furnace brazed using two common FMs, BNi-2 and BNi-9. Metallurgical characterization of these brazed joints showed two primary microstructural regions; a soft

  8. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  9. The joint venture alternative to mergers.

    PubMed

    Enders, R J

    1995-02-01

    However, while a joint venture may be "safe" from antitrust challenge, it is not without some practical difficulties, especially with respect to consolidating services at one location or jointly offering services provided at multiple facilities. These practical concerns include: 1. Who will exercise operational management of the joint venture? 2. How will the joint venture deal with different pricing for services that will be provided at multiple locations? 3. What criteria will be used to decide the location at which consolidated tertiary services will be offered? 4. In what circumstances can the joint venture be unwound, either in its entirety or as to discrete functions? When clinical services have been consolidated at one location, there is an appropriate concern by the other hospital that it will be unable to provide or re-enter the market for those services if the joint venture dissolves. These operational concerns, of course, are not addressed in the Consent Decree. Thus, even if a joint venture relationship survives antitrust scrutiny, the parties must still negotiate and resolve these operational issues in order for the joint venture to be viable.

  10. Joint Doctrine for Electronic Warfare

    DTIC Science & Technology

    2000-04-07

    Command, Control, Communications, and Computer Systems Directorate (J-6) and the Intelligence Directorate (J-2). The joint restricted frequency list (JRFL...for exercises and operations within the operational area. EW interests in the preparation of the joint restricted frequency list for specific... frequency list (JRFL) for approval by the J-3 (through the information operations [IO] cell or equivalent). Periodically updates and distributes the JRFL

  11. Operation Joint Endeavor in Bosnia: telemedicine systems and case reports.

    PubMed

    Calcagni, D E; Clyburn, C A; Tomkins, G; Gilbert, G R; Cramer, T J; Lea, R K; Ehnes, S G; Zajtchuk, R

    1996-01-01

    For the last several years the U.S. Department of Defense (DoD) has operated a telemedicine test bed at the U.S. Army Medical Research and Material Command's Medical Advanced Technology Management Office. The goal of this test bed is to reengineer the military health service system from the most forward deployed forces to tertiary care teaching medical centers within the United States by exploiting emerging telemedicine technologies. The test bed has conducted numerous proof-of-concept telemedicine demonstrations as part of military exercises and in support of real-world troop deployments. The most ambitious of those demonstrations is Primetime III, an ongoing effort to provide telemedicine and other advanced technology support to medical units supporting Operation Joint Endeavor in Bosnia. Several of the first instances of the clinical use of the Primetime III systems are presented as case reports in this paper. These reports demonstrate capabilities and limitations of telemedicine. The Primetime III system demonstrates the technical ability to provide current telecommunications capabilities to medical units stationed in the remote, austere, difficult-to-serve environment of Bosnia. Telemedicine capabilities cannot be used without adequate training, operations, and sustainment support. Video consultations have eliminated the need for some evacuations. The system has successfully augmented the clinical capability of physicians assigned to these medical units. Fullest clinical utilization of telemedicine technologies requires adjustment of conventional clinical practice patterns.

  12. IMU-Based Joint Angle Measurement for Gait Analysis

    PubMed Central

    Seel, Thomas; Raisch, Jorg; Schauer, Thomas

    2014-01-01

    This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods that may cope with this challenge, we present a set of new methods for: (1) joint axis and position identification; and (2) flexion/extension joint angle measurement. In particular, we propose methods that use only gyroscopes and accelerometers and, therefore, do not rely on a homogeneous magnetic field. We provide results from gait trials of a transfemoral amputee in which we compare the inertial measurement unit (IMU)-based methods to an optical 3D motion capture system. Unlike most authors, we place the optical markers on anatomical landmarks instead of attaching them to the IMUs. Root mean square errors of the knee flexion/extension angles are found to be less than 1° on the prosthesis and about 3° on the human leg. For the plantar/dorsiflexion of the ankle, both deviations are about 1°. PMID:24743160

  13. Argumentation Based Joint Learning: A Novel Ensemble Learning Approach

    PubMed Central

    Xu, Junyi; Yao, Li; Li, Le

    2015-01-01

    Recently, ensemble learning methods have been widely used to improve classification performance in machine learning. In this paper, we present a novel ensemble learning method: argumentation based multi-agent joint learning (AMAJL), which integrates ideas from multi-agent argumentation, ensemble learning, and association rule mining. In AMAJL, argumentation technology is introduced as an ensemble strategy to integrate multiple base classifiers and generate a high performance ensemble classifier. We design an argumentation framework named Arena as a communication platform for knowledge integration. Through argumentation based joint learning, high quality individual knowledge can be extracted, and thus a refined global knowledge base can be generated and used independently for classification. We perform numerous experiments on multiple public datasets using AMAJL and other benchmark methods. The results demonstrate that our method can effectively extract high quality knowledge for ensemble classifier and improve the performance of classification. PMID:25966359

  14. Development of brazing process for W-EUROFER joints using Cu-based fillers

    NASA Astrophysics Data System (ADS)

    de Prado, J.; Sánchez, M.; Ureña, A.

    2016-02-01

    A successful joint between W and EUROFER using high temperature brazing technique has been achieved for structural application in future fusion power plants. Cu-based powder alloy mixed with a polymeric binder has been used as filler. Microstructural analysis of the joints revealed that the joint consisted mainly of primary phases and acicular structures in a Cu matrix. Interaction between EUROFER and filler took place at the interface giving rise to several Cu-Ti-Fe rich layers. A loss of hardness at the EUROFER substrate close to the joint due to a diffusion phenomenon during brazing cycle was measured; however, the joints had an adequate shear strength value.

  15. Joint Implications for Contracted Logistics

    DTIC Science & Technology

    2007-03-30

    authority with the host nation country and policy on using UCMJ for contracted personnel. As tailored theater policies are developed and contracting...responsibility, this paper recommends better joint training, leader development and joint enablers for contracting operations. JOINT...U.S. Joint Forces Command (JFCOM) are analyzing Congressional and DOD policy to develop procedures and force structure to support contractor

  16. A universal six-joint robot controller

    NASA Technical Reports Server (NTRS)

    Bihn, D. G.; Hsia, T. C.

    1987-01-01

    A general purpose six-axis robotic manipulator controller was designed and implemented to serve as a research tool for the investigation of the practical and theoretical aspects of various control strategies in robotics. A 80286-based Intel System 310 running the Xenix operating servo software as well as the higher level software (e.g., kinematics and path planning) were employed. A Multibus compatible interface board was designed and constructed to handle I/O signals from the robot manipulator's joint motors. From the design point of view, the universal controller is capable of driving robot manipulators equipped with D.C. joint motors and position optical encoders. To test its functionality, the controller is connected to the joint motor D.C. power amplifier of a PUMA 560 arm bypassing completely the manufacturer-supplied Unimation controller. A controller algorithm consisting of local PD control laws was written and installed into the Xenix operating system. Additional software drivers were implemented to allow application programs access to the interface board. All software was written in the C language.

  17. Joint Forward Operating Base Elements of Command and Control

    DTIC Science & Technology

    2002-01-01

    augmenting the fixed en route locations or establishing en route locations where none exist are also an integral part of this system” (AFDD 2- 6 1999, 57... section at CARL. 6 . Justification: Justification is required for any distribution other than described in Distribution Statement A. All or part of...Theater Airlift Operations, assigns the USAF the responsibility of providing airlift and the accompanying en route C4 structure to all US services

  18. [Sports participation after joint arthroplasty].

    PubMed

    Dauty, M; Letenneur, J

    2007-12-01

    To recommand sports activities after joint arthroplasty from the literature analysis, the French surgeon's opinion and wish patients. From the Medline data base interrogation according to keywords: Sports, Arthroplasty, Athletics, Physical training, two different readers, an orthopedic surgeon and a Physical Medicine and Rehabilitation physician selected articles in French or English language according to the level of proofs of the french classification of the Accreditation and Health Evaluation National Agency (Anaes). Professional practices were estimated by the interrogation of 30 orthopedic surgeons members of the french West Orthopaedics Society (SOO). The demand of sports practice was studied with patients recently operated for a primary total knee arthroplasty (TKA) after gonarthrosis. Twenty-two articles were selected from 305 articles obtained by the search according to keywords. Ten literature reviews are limited by the absence of prospective randomized study. A level II study and eleven level IV articles are reported. According to the subjective orthropedic surgeon's opinion, the objective results based on the joint load studied and the percentage of arthroplasty revision, sport is beneficial for the individual health but perhaps not for the arthroplasty survey. However, aerobic and leisure activities are recommended (walking, swimming, cycling) in agreement with the demand of the patients recently operated with a TKA. TKA differs from Total Hip Arthroplasty for jogging because of knee joint constraints during the knee flexion. A single study reports sports possibilities after shoulder arthroplasty and ankle arthroplasty and no study reports results after elbow arthroplasty.

  19. Applied Concept:The Military Information Operations Function within a Comprehensive and Effects-Based Approach

    DTIC Science & Technology

    2009-04-03

    Bonn, Germany 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) USJFCOM J9 Joint Concept...Bonn, Germany , The original document contains color images. 14. ABSTRACT This concept paper is based on the Multinational Information Operations...Bonn, Germany 24 25 Phone: +49 (0)228 43320-464 E-mail: peterwestenkirchner@bundeswehr.org 26 UNCLASSIFIED FOR PUBLIC RELEASE – The Military

  20. Image Registration-Based Bolt Loosening Detection of Steel Joints

    PubMed Central

    2018-01-01

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts. PMID:29597264

  1. Image Registration-Based Bolt Loosening Detection of Steel Joints.

    PubMed

    Kong, Xiangxiong; Li, Jian

    2018-03-28

    Self-loosening of bolts caused by repetitive loads and vibrations is one of the common defects that can weaken the structural integrity of bolted steel joints in civil structures. Many existing approaches for detecting loosening bolts are based on physical sensors and, hence, require extensive sensor deployment, which limit their abilities to cost-effectively detect loosened bolts in a large number of steel joints. Recently, computer vision-based structural health monitoring (SHM) technologies have demonstrated great potential for damage detection due to the benefits of being low cost, easy to deploy, and contactless. In this study, we propose a vision-based non-contact bolt loosening detection method that uses a consumer-grade digital camera. Two images of the monitored steel joint are first collected during different inspection periods and then aligned through two image registration processes. If the bolt experiences rotation between inspections, it will introduce differential features in the registration errors, serving as a good indicator for bolt loosening detection. The performance and robustness of this approach have been validated through a series of experimental investigations using three laboratory setups including a gusset plate on a cross frame, a column flange, and a girder web. The bolt loosening detection results are presented for easy interpretation such that informed decisions can be made about the detected loosened bolts.

  2. Field homogeneity improvement of maglev NdFeB magnetic rails from joints.

    PubMed

    Li, Y J; Dai, Q; Deng, C Y; Sun, R X; Zheng, J; Chen, Z; Sun, Y; Wang, H; Yuan, Z D; Fang, C; Deng, Z G

    2016-01-01

    An ideal magnetic rail should provide a homogeneous magnetic field along the longitudinal direction to guarantee the reliable friction-free operation of high temperature superconducting (HTS) maglev vehicles. But in reality, magnetic field inhomogeneity may occur due to lots of reasons; the joint gap is the most direct one. Joint gaps inevitably exist between adjacent segments and influence the longitudinal magnetic field homogeneity above the rail since any magnetic rails are consisting of many permanent magnet segments. To improve the running performance of maglev systems, two new rail joints are proposed based on the normal rail joint, which are named as mitered rail joint and overlapped rail joint. It is found that the overlapped rail joint has a better effect to provide a competitive homogeneous magnetic field. And the further structure optimization has been done to ensure maglev vehicle operation as stable as possible when passing through those joint gaps. The results show that the overlapped rail joint with optimal parameters can significantly reduce the magnetic field inhomogeneity comparing with the other two rail joints. In addition, an appropriate gap was suggested when balancing the thermal expansion of magnets and homogenous magnetic field, which is considered valuable references for the future design of the magnetic rails.

  3. Contingency Base Camp Operations and Management: Staffing and Organization

    DTIC Science & Technology

    2013-09-17

    security, safety , environmental and health risks to deployed forces. This study was undertaken to address operations and management (O&M) requirements...security, safety , envi- ronmental and health risks to deployed forces. This study was undertaken to address operations and management (O&M) requirements... food service oversight • Joint Visitor Bureau ERDC/CERL TR-13-18 16 • MWR. TF Archer was significantly augmented with engineer personnel to

  4. An experimentally based nonlinear viscoelastic model of joint passive moment.

    PubMed

    Esteki, A; Mansour, J M

    1996-04-01

    Previous investigations have not converged on a generally accepted model of the dissipative part of joint passive moment. To provide a basis for developing a model, a series of measurements were performed to characterize the passive moment at the metacarpophalangeal joint of the index finger. Two measurement procedures were used, one in moment relaxation over a range of fixed joint angles and the other at a series of constant joint velocities. Fung's quasi-linear viscoelastic theory motivated the development of the passive moment model. Using this approach, it was not necessary to make restrictive assumptions regarding the viscoelastic behavior of the passive moment. The generality of the formulation allowed specific functions to be chosen based on experimental data rather than finding coefficients which attempted to fit a preselected model of the data. It was shown that a nonlinear viscoelastic model described the passive stiffness. No significant frictional effects were found. Of particular importance was the nonlinear behavior of the dissipative part of the passive moment which was modeled by joint speed raised to a power less than one. This result could explain the differing findings among previous investigations, and may have important implications for control of limb movement.

  5. [Osseous and soft tissue operations for treatment of joint malpositioning in infantile cerebral palsy].

    PubMed

    Senst, S

    2013-12-01

    If untreated infantile cerebral palsy (ICP) leads to a progressive shortening of muscles and to progressive joint malpositioning. In addition a number of other disorders also result, in particular sensory disorders, intelligence deficits and epilepsy. In order to optimally treat as many as possible of the problems of multi-handicapped children with ICP it is of immanent importance that physiotherapists, occupational therapists, speech therapists, orthopedic technicians, pediatric orthopedists as well as neuropediatricians and social pediatricians work as a team. Surgical measures to correct joint malpositioning serve to improve the function and also to avoid or alleviate pain. Functional improvement measures are ideally undertaken during or shortly before elementary school age, thus enabling a further verticalization/straightening and mobilization. To improve symmetry and therefore the sitting posture, surgery is also indicated for profoundly disabled patients, sometimes making foot operations necessary. It is only in this way that maximum participation can be guaranteed and if necessary utilizing additional aids, such as Zimmer frames or E-wheelchairs.

  6. Grinding assembly, grinding apparatus, weld joint defect repair system, and methods

    DOEpatents

    Larsen, Eric D.; Watkins, Arthur D.; Bitsoi, Rodney J.; Pace, David P.

    2005-09-27

    A grinding assembly for grinding a weld joint of a workpiece includes a grinder apparatus, a grinder apparatus includes a grinding wheel configured to grind the weld joint, a member configured to receive the grinding wheel, the member being configured to be removably attached to the grinder apparatus, and a sensor assembly configured to detect a contact between the grinding wheel and the workpiece. The grinding assembly also includes a processing circuitry in communication with the grinder apparatus and configured to control operations of the grinder apparatus, the processing circuitry configured to receive weld defect information of the weld joint from an inspection assembly to create a contour grinding profile to grind the weld joint in a predetermined shape based on the received weld defect information, and a manipulator having an end configured to carry the grinder apparatus, the manipulator further configured to operate in multiple dimensions.

  7. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  8. STS payloads mission control study. Volume 2-A, Task 1: Joint products and functions for preflight planning of flight operations, training and simulations

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Specific products and functions, and associated facility availability, applicable to preflight planning of flight operations were studied. Training and simulation activities involving joint participation of STS and payload operations organizations, are defined. The prelaunch activities required to prepare for the payload flight operations are emphasized.

  9. DefenseLink Special: Joint Civilian Orientation Conference, JCOC 71, April

    Science.gov Websites

    Websites Contact Us Joint Civilian Orientation Conference 71 Multi-Service Orientation Program for Civilian in the Middle East: how the U.S. Coast Guard is helping keep Iraq's offshore oil terminals operating -improvised explosive device training at Forward Operating Base Sword in Kuwait, April 26, 2006. Hendrickson

  10. Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score: a radiographic method to detect osteoarthritis of the interphalangeal finger joints based on its histopathological alterations.

    PubMed

    Sunk, Ilse-Gerlinde; Amoyo-Minar, Love; Stamm, Tanja; Haider, Stefanie; Niederreiter, Birgit; Supp, Gabriela; Soleiman, Afschin; Kainberger, Franz; Smolen, Josef S; Bobacz, Klaus

    2014-11-01

    To develop a radiographic score for assessment of hand osteoarthritis (OA) that is based on histopathological alterations of the distal (DIP) and proximal (PIP) interphalangeal joints. DIP and PIP joints were obtained from corpses (n=40). Plain radiographies of these joints were taken. Joint samples were prepared for histological analysis; cartilage damage was graded according to the Mankin scoring system. A 2×2 Fisher's exact test was applied to define those radiographic features most likely to be associated with histological alterations. Receiver operating characteristic curves were analysed to determine radiographic thresholds. Intraclass correlation coefficients (ICC) estimated intra- and inter-reader variability. Spearman's correlation was applied to examine the relationship between our score and histopathological changes. Differences between groups were determined by a Student's t test. The Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score is presented. The score is based on histopathological changes of DIP and PIP joints and follows a simple dichotomy whether OA is present or not. The iOARS score relies on three equally ranked radiographic features (osteophytes, joint space narrowing and subchondral sclerosis). For both DIP and PIP joints, the presence of one x-ray features reflects interphalangeal OA. Sensitivity and specificity for DIP joints were 92.3% and 90.9%, respectively, and 75% and 100% for PIP joints. All readers were able to reproduce their own readings in DIP and PIP joints after 4 weeks. The overall agreement between the three readers was good; ICCs ranged from 0.945 to 0.586. Additionally, outcomes of the iOARS score in a hand OA cohort revealed a higher prevalence of interphalangeal joint OA compared with the Kellgren and Lawrence score. The iOARS score is uniquely based on histopathological alterations of the interphalangeal joints in order to reliably determine OA of the DIP and PIP joints radiographically. Its high

  11. Sensitivity of a juvenile subject-specific musculoskeletal model of the ankle joint to the variability of operator-dependent input.

    PubMed

    Hannah, Iain; Montefiori, Erica; Modenese, Luca; Prinold, Joe; Viceconti, Marco; Mazzà, Claudia

    2017-05-01

    Subject-specific musculoskeletal modelling is especially useful in the study of juvenile and pathological subjects. However, such methodologies typically require a human operator to identify key landmarks from medical imaging data and are thus affected by unavoidable variability in the parameters defined and subsequent model predictions. The aim of this study was to thus quantify the inter- and intra-operator repeatability of a subject-specific modelling methodology developed for the analysis of subjects with juvenile idiopathic arthritis. Three operators each created subject-specific musculoskeletal foot and ankle models via palpation of bony landmarks, adjustment of geometrical muscle points and definition of joint coordinate systems. These models were then fused to a generic Arnold lower limb model for each of three modelled patients. The repeatability of each modelling operation was found to be comparable to those previously reported for the modelling of healthy, adult subjects. However, the inter-operator repeatability of muscle point definition was significantly greater than intra-operator repeatability ( p < 0.05) and predicted ankle joint contact forces ranged by up to 24% and 10% of the peak force for the inter- and intra-operator analyses, respectively. Similarly, the maximum inter- and intra-operator variations in muscle force output were 64% and 23% of peak force, respectively. Our results suggest that subject-specific modelling is operator dependent at the foot and ankle, with the definition of muscle geometry the most significant source of output uncertainty. The development of automated procedures to prevent the misplacement of crucial muscle points should therefore be considered a particular priority for those developing subject-specific models.

  12. [Displacement and tissue remodeling of temporomandibular joint disc].

    PubMed

    Wang, M Q

    2017-03-09

    Sounding takes the highest prevalence of the signs of temporomandibular disorders (TMD). The well accepted theory of the mechanism for temporomandibular joint (TMJ) sounding is the internal derangement typically characterized by disc displacement. However, according to literature, there are approximately one third of asymptomatic joints in population had disc displacement, and, on the other hand, there are one fourth of TMJ sounding patients had not signs or very limited signs of disc displacement. Replacing the displaced disc to the normal position via methods like surgical operation did not achieve satisfactory long-term outcomes. In this review, we discuss and analyze the possible remodeling of the joint disc displacement diagnosed with imaging based on the anatomy and pathophysiology.

  13. Joint Urban Operations Joint Integrating Concept

    DTIC Science & Technology

    2007-07-23

    24 7. Potential Risks of Adopting this Concept...stresses that urban combat operations are conducted only when required and that built-up areas are isolated and bypassed rather than risking a...Development, Applications (New York: George Braziller , 1968). 7 media, etc., institutions that typify urban society.15 The processes include all

  14. A low cost wearable optical-based goniometer for human joint monitoring

    NASA Astrophysics Data System (ADS)

    Lim, Chee Kian; Luo, Zhiqiang; Chen, I.-Ming; Yeo, Song Huat

    2011-03-01

    Widely used in the fields of physical and occupational therapy, goniometers are indispensible when it comes to angular measurement of the human joint. In both fields, there is a need to measure the range of motion associated with various joints and muscle groups. For example, a goniometer may be used to help determine the current status of the range of motion in bend the arm at the elbow, bending the knee, or bending at the waist. The device can help to establish the range of motion at the beginning of the treatment series, and also allow the therapist to monitor progress during subsequent sessions. Most commonly found are the mechanical goniometers which are inexpensive but bulky. As the parts are mechanically linked, accuracy and resolution are largely limited. On the other hand, electronic and optical fiberbased goniometers promise better performance over its mechanical counterpart but due to higher cost and setup requirements does not make it an attractive proposition as well. In this paper, we present a reliable and non-intrusive design of an optical-based goniometer for human joint measurement. This device will allow continuous and longterm monitoring of human joint motion in everyday setting. The proposed device was benchmarked against mechanical goniometer and optical based motion capture system to validate its performance. From the empirical results, it has been proven that this design can be use as a robust and effective wearable joint monitoring device.

  15. Joint sparse coding based spatial pyramid matching for classification of color medical image.

    PubMed

    Shi, Jun; Li, Yi; Zhu, Jie; Sun, Haojie; Cai, Yin

    2015-04-01

    Although color medical images are important in clinical practice, they are usually converted to grayscale for further processing in pattern recognition, resulting in loss of rich color information. The sparse coding based linear spatial pyramid matching (ScSPM) and its variants are popular for grayscale image classification, but cannot extract color information. In this paper, we propose a joint sparse coding based SPM (JScSPM) method for the classification of color medical images. A joint dictionary can represent both the color information in each color channel and the correlation between channels. Consequently, the joint sparse codes calculated from a joint dictionary can carry color information, and therefore this method can easily transform a feature descriptor originally designed for grayscale images to a color descriptor. A color hepatocellular carcinoma histological image dataset was used to evaluate the performance of the proposed JScSPM algorithm. Experimental results show that JScSPM provides significant improvements as compared with the majority voting based ScSPM and the original ScSPM for color medical image classification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Joint Operations. Change 1

    DTIC Science & Technology

    2008-02-13

    procedures not ratified by the United States, commanders should evaluate and follow the multinational command’s doctrine and procedures, where applicable... human intelligence sources to be effective and implementation of appropriate force protection measures regardless of the operational...intelligence requirements needed to support the anticipated operation. Human intelligence often may provide the most useful source of information. Even

  17. [COMPARISON OF EFFECTIVENESS BETWEEN TWO OPERATIVE TECHNIQUES OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION FOR TREATMENT OF Tossy TYPE III ACROMIOCLAVICULAR JOINT DISLOCATION].

    PubMed

    Tang, Hongwei; Gao, Sheng; Yin, Yong; Li, Yunfei; Han, Qingtian; Li, Huizhang

    2015-11-01

    To evaluate and compare the effectiveness of double Endobutton technique and suture anchor combined Endobutton plate in the treatment of Tossy type III acromioclavicular joint dislocation. Between May 2010 and March 2014, a retrospective study was preformed on 56 patients with Tossy type III acromioclavicular joint dislocation. The coracoclavicular ligament was reconstructed with double Endobutton technique in 31 cases (Endobutton group), and with suture anchor combined Endobutton plate in 25 cases (Anchor group). There was no significant difference in age, gender, injury causes, injury side, associated injury, medical comorbidities, and disease duration between 2 groups (P>0.05). The operation time, medical device expenses, postoperative complications, preoperative and postoperative Constant-Murley scores, and postoperative Karlsson grading of the injured shoulder were compared between 2 groups. The average operation time in Endobutton group was significantly greater than that in Anchor group (t = 4.285, P = 0.000); there was no significant difference in the medical device expenses between 2 groups (t = 1.555, P = 0.126). Primary healing of incision was obtained in all patients of 2 groups; no early complications of infection and skin necrosis occurred. All patients were followed up 15.6 months on average (range, 11-35 months). During follow-up, some loss of reduction and ectopic ossification in the coracoclavicular gap were observed in 1 case and 6 cases of Endobutton group, respectively. No recurrence of acromioclavicular joint dislocation, implant fixation loosening and broken, and secondary fractures occurred in the other patients. There was significant difference in the incidence of postoperative complications between 2 groups (P = 0.013). Constant-Murley scores of the injured shoulder significantly increased at 9 months after operation when compared with preoperative values in 2 groups (P < 0.05), but no significant difference was observed between 2 groups

  18. Structural Degradation of the Welded Joint of the Gas Main after a Long-Term Operation in Sub-Acid Soil

    NASA Astrophysics Data System (ADS)

    Maruschak, P. O.; Bishchak, R. T.; Maruschak, O. V.; Panin, S. V.

    2018-01-01

    The authors investigated the main regularities in the structural and mechanical degradation of steel and a welded joint of the “Soyuz” gas main in operation. It is established that the defect accumulation kinetics in welds are determined both by technological disruptions in their manufacture and by hydrogenation of the weld during a long operating time. A weakening of the mechanical properties of the weld after a prolonged operation is shown, which in some cases led to the appearance of cracks and fracture of the gas main.

  19. Joint Operating Environment: The Joint Force in a Contested and Disordered World

    DTIC Science & Technology

    2016-07-14

    spilling over borders, and creating wide-ranging international problems. The future of Science, Technology, and Engineering will see others reaching...10 Science, Technology, and Engineering and the Future Joint Force ..........................................15 Summary... Engineering – may lead to new and challenging conditions that will redefine the security environment of 2035.  Section 2: Contexts of Future Conflict

  20. Final Environmental Assessment: For Joint Base Anacostia-Bolling Master Plan District of Columbia

    DTIC Science & Technology

    2010-09-30

    the impacts of vehicle travel and facilitate alternative modes of transportation that would reduce air pollutants . Noise: There would be...ltlb•nKM nr~t~~G.,~ StEiiubetlls Fort McNair East Potomac Pari < Poplar Point "" Joint Base Anacostia-Bolling Master Plan Environmental...Industrial $uppon Eost Potomac Pari < Poplar Point Joint Base Anacostia-Bolling Master Plan Environmental Assessment pg. 16 Several general

  1. Registration of knee joint surfaces for the in vivo study of joint injuries based on magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Cheng, Rita W. T.; Habib, Ayman F.; Frayne, Richard; Ronsky, Janet L.

    2006-03-01

    In-vivo quantitative assessments of joint conditions and health status can help to increase understanding of the pathology of osteoarthritis, a degenerative joint disease that affects a large population each year. Magnetic resonance imaging (MRI) provides a non-invasive and accurate means to assess and monitor joint properties, and has become widely used for diagnosis and biomechanics studies. Quantitative analyses and comparisons of MR datasets require accurate alignment of anatomical structures, thus image registration becomes a necessary procedure for these applications. This research focuses on developing a registration technique for MR knee joint surfaces to allow quantitative study of joint injuries and health status. It introduces a novel idea of translating techniques originally developed for geographic data in the field of photogrammetry and remote sensing to register 3D MR data. The proposed algorithm works with surfaces that are represented by randomly distributed points with no requirement of known correspondences. The algorithm performs matching locally by identifying corresponding surface elements, and solves for the transformation parameters relating the surfaces by minimizing normal distances between them. This technique was used in three applications to: 1) register temporal MR data to verify the feasibility of the algorithm to help monitor diseases, 2) quantify patellar movement with respect to the femur based on the transformation parameters, and 3) quantify changes in contact area locations between the patellar and femoral cartilage at different knee flexion angles. The results indicate accurate registration and the proposed algorithm can be applied for in-vivo study of joint injuries with MRI.

  2. Nonlinear structural joint model updating based on instantaneous characteristics of dynamic responses

    NASA Astrophysics Data System (ADS)

    Wang, Zuo-Cai; Xin, Yu; Ren, Wei-Xin

    2016-08-01

    This paper proposes a new nonlinear joint model updating method for shear type structures based on the instantaneous characteristics of the decomposed structural dynamic responses. To obtain an accurate representation of a nonlinear system's dynamics, the nonlinear joint model is described as the nonlinear spring element with bilinear stiffness. The instantaneous frequencies and amplitudes of the decomposed mono-component are first extracted by the analytical mode decomposition (AMD) method. Then, an objective function based on the residuals of the instantaneous frequencies and amplitudes between the experimental structure and the nonlinear model is created for the nonlinear joint model updating. The optimal values of the nonlinear joint model parameters are obtained by minimizing the objective function using the simulated annealing global optimization method. To validate the effectiveness of the proposed method, a single-story shear type structure subjected to earthquake and harmonic excitations is simulated as a numerical example. Then, a beam structure with multiple local nonlinear elements subjected to earthquake excitation is also simulated. The nonlinear beam structure is updated based on the global and local model using the proposed method. The results show that the proposed local nonlinear model updating method is more effective for structures with multiple local nonlinear elements. Finally, the proposed method is verified by the shake table test of a real high voltage switch structure. The accuracy of the proposed method is quantified both in numerical and experimental applications using the defined error indices. Both the numerical and experimental results have shown that the proposed method can effectively update the nonlinear joint model.

  3. Sensitivity of a juvenile subject-specific musculoskeletal model of the ankle joint to the variability of operator-dependent input

    PubMed Central

    Hannah, Iain; Montefiori, Erica; Modenese, Luca; Prinold, Joe; Viceconti, Marco; Mazzà, Claudia

    2017-01-01

    Subject-specific musculoskeletal modelling is especially useful in the study of juvenile and pathological subjects. However, such methodologies typically require a human operator to identify key landmarks from medical imaging data and are thus affected by unavoidable variability in the parameters defined and subsequent model predictions. The aim of this study was to thus quantify the inter- and intra-operator repeatability of a subject-specific modelling methodology developed for the analysis of subjects with juvenile idiopathic arthritis. Three operators each created subject-specific musculoskeletal foot and ankle models via palpation of bony landmarks, adjustment of geometrical muscle points and definition of joint coordinate systems. These models were then fused to a generic Arnold lower limb model for each of three modelled patients. The repeatability of each modelling operation was found to be comparable to those previously reported for the modelling of healthy, adult subjects. However, the inter-operator repeatability of muscle point definition was significantly greater than intra-operator repeatability (p < 0.05) and predicted ankle joint contact forces ranged by up to 24% and 10% of the peak force for the inter- and intra-operator analyses, respectively. Similarly, the maximum inter- and intra-operator variations in muscle force output were 64% and 23% of peak force, respectively. Our results suggest that subject-specific modelling is operator dependent at the foot and ankle, with the definition of muscle geometry the most significant source of output uncertainty. The development of automated procedures to prevent the misplacement of crucial muscle points should therefore be considered a particular priority for those developing subject-specific models. PMID:28427313

  4. The impact of joint ventures on U.S. hospitals.

    PubMed

    Harrison, Jeffrey P

    2006-01-01

    This quantitative research study assesses the organizational characteristics, market factors, and profitability of US hospitals that operate joint ventures with other health care organizations. Data was obtained from the 2001 American Hospital Association annual survey, the Area Resource File, and the Center for Medicare and Medicaid Services Minimum Data Set. These data files provide essential information on individual acute care hospitals, the communities they serve, and the level of financial performance. Descriptive statistics were evaluated and a logistic regression model was utilized to examine hospitals operating joint ventures. The study found hospitals that operate joint ventures are located in communities with more elderly patients, lower unemployment, and lower HMO penetration. From an operating performance perspective, hospitals that operate joint ventures have a higher occupancy rate, a higher average length of stay, more clinical services, lower long-term debt, and a greater number of managed care contracts. The results also appear to indicate that joint ventures have a positive financial impact on US hospitals. The study has managerial implications supporting the use of joint ventures to improve hospital performance and policy implications on resource allocation.

  5. Audio-based bolt-loosening detection technique of bolt joint

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Zhao, Xuefeng; Su, Wensheng; Xue, Zhigang

    2018-03-01

    Bolt joint, as the commonest coupling structure, is widely used in electro-mechanical system. However, it is the weakest part of the whole system. The increase of preload tension force can raise the reliability and strength of the bolt joint. Therefore, the pretension force is one of the most important factors to ensure the stability of bolt joint. According to the way of generating pretension force, the pretension force can be monitored by bolt torque, degrees and elongation. The existing bolt-loosening monitoring methods all require expensive equipment, which greatly restricts the practicality of the bolt-loosening monitoring. In this paper, a new method of bolt-loosening detection technique based on audio is proposed. The sound that bolt is hit by a hammer is recorded on the Smartphone, and the collected audio signal is classified and identified by support vector machine algorithm. First, a verification test was designed and the results show that this new method can identify the damage of bolt looseness accurately. Second, a variety of bolt-loosening was identified. The results indicate that this method has a high accuracy in multiclass classification of the bolt looseness. This bolt-loosening detection technique based on audio not only can reduce the requirements of technical and professional experience, but also make bolt-loosening monitoring simpler and easier.

  6. Capital planning for operating theatres based on projecting future theatre requirements.

    PubMed

    Sheehan, Jennifer A; Tyler, Peter; Jayasinha, Hirani; Meleady, Kathleen T; Jones, Neill

    2011-05-01

    During 2006, NSW and ACT Health Departments jointly engaged KPMG to develop an Operating Theatre Requirements' Projection Model and an accompanying planning guideline. A research scan was carried out to identify drivers of surgical demand, theatre capacity and theatre performance, as well as locating existing approaches to modelling operating theatre requirements for planning purposes. The project delivered a Microsoft Excel-based model for projecting future operating theatre requirements, together with an accompanying guideline for use of the model and interpretation of its outputs. It provides a valuable addition to the suite of tools available to Health staff for service and capital planning. The model operates with several limitations, largely due to being data dependent, and the state and completeness of available theatre activity data. However, the operational flexibility built into the model allows users to compensate for these limitations, on a case by case basis, when the user has access to suitable, local data. The design flexibility of the model means that updating the model as improved data become available is not difficult; resulting in revisions being able to be made quickly, and disseminated to users rapidly.

  7. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    PubMed

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Mind Operational Semantics and Brain Operational Architectonics: A Putative Correspondence

    PubMed Central

    Benedetti, Giulio; Marchetti, Giorgio; Fingelkurts, Alexander A; Fingelkurts, Andrew A

    2010-01-01

    Despite allowing for the unprecedented visualization of brain functional activity, modern neurobiological techniques have not yet been able to provide satisfactory answers to important questions about the relationship between brain and mind. The aim of this paper is to show how two different but complementary approaches, Mind Operational Semantics (OS) and Brain Operational Architectonics (OA), can help bridge the gap between a specific kind of mental activity—the higher-order reflective thought or linguistic thought—and brain. The fundamental notion that allows the two different approaches to be jointly used under a common framework is that of operation. According to OS, which is based on introspection and linguistic data, the meanings of words can be analyzed in terms of elemental mental operations (EOMC), amongst which those of attention play a key role. Linguistic thought is made possible by special kinds of elements, which OS calls “correlators”, which have the function of tying together the other elements of thought, which OS calls “correlata” (a "correlational network” that is, a sentence, is so formed). Therefore, OS conceives of linguistic thought as a hierarchy of operations of increasing complexity. Likewise, according to OA, which is based on the joint analysis of cognitive and electromagnetic data (EEG and MEG), every conscious phenomenon is brought to existence by the joint operations of many functional and transient neuronal assemblies in the brain. According to OA, the functioning of the brain is always operational (made up of operations), and its structure is characterized by a hierarchy of operations of increasing complexity: single neurons, single assemblies of neurons, synchronized neuronal assemblies or Operational Modules (OM), integrated or complex OMs. The authors put forward the hypothesis that the whole level of OS’s description (EOMC, correlators, and correlational networks) corresponds to the level of OMs (or set of them

  9. Air-Sea Battle through Joint Training: Power Projection Sustainability

    DTIC Science & Technology

    2014-05-15

    9 generate our decisive advantage.” 39 An example of cross-domain operations employed by the USN and USAF was the release of an AGM-154C Joint...and Herzegovina. While employing a USAF GBU -15 “electro-optically guided” bomb within close range of a USN AGM-84 SLAM-ER, “electronic... 39 U.S. Office of the Chairman, Joint Chiefs of Staff. Capstone Concept for Joint Operations: Joint Force 2020

  10. An all-joint-control master device for single-port laparoscopic surgery robots.

    PubMed

    Shim, Seongbo; Kang, Taehun; Ji, Daekeun; Choi, Hyunseok; Joung, Sanghyun; Hong, Jaesung

    2016-08-01

    Robots for single-port laparoscopic surgery (SPLS) typically have all of their joints located inside abdomen during surgery, whereas with the da Vinci system, only the tip part of the robot arm is inserted and manipulated. A typical master device that controls only the tip with six degrees of freedom (DOFs) is not suitable for use with SPLS robots because of safety concerns. We designed an ergonomic six-DOF master device that can control all of the joints of an SPLS robot. We matched each joint of the master, the slave, and the human arm to decouple all-joint motions of the slave robot. Counterbalance masses were used to reduce operator fatigue. Mapping factors were determined based on kinematic analysis and were used to achieve all-joint control with minimal error at the tip of the slave robot. The proposed master device has two noteworthy features: efficient joint matching to the human arm to decouple each joint motion of the slave robot and accurate mapping factors, which can minimize the trajectory error of the tips between the master and the slave. We confirmed that the operator can manipulate the slave robot intuitively with the master device and that both tips have similar trajectories with minimal error.

  11. Joint source based morphometry identifies linked gray and white matter group differences.

    PubMed

    Xu, Lai; Pearlson, Godfrey; Calhoun, Vince D

    2009-02-01

    We present a multivariate approach called joint source based morphometry (jSBM), to identify linked gray and white matter regions which differ between groups. In jSBM, joint independent component analysis (jICA) is used to decompose preprocessed gray and white matter images into joint sources and statistical analysis is used to determine the significant joint sources showing group differences and their relationship to other variables of interest (e.g. age or sex). The identified joint sources are groupings of linked gray and white matter regions with common covariation among subjects. In this study, we first provide a simulation to validate the jSBM approach. To illustrate our method on real data, jSBM is then applied to structural magnetic resonance imaging (sMRI) data obtained from 120 chronic schizophrenia patients and 120 healthy controls to identify group differences. JSBM identified four joint sources as significantly associated with schizophrenia. Linked gray-white matter regions identified in each of the joint sources included: 1) temporal--corpus callosum, 2) occipital/frontal--inferior fronto-occipital fasciculus, 3) frontal/parietal/occipital/temporal--superior longitudinal fasciculus and 4) parietal/frontal--thalamus. Age effects on all four joint sources were significant, but sex effects were significant only for the third joint source. Our findings demonstrate that jSBM can exploit the natural linkage between gray and white matter by incorporating them into a unified framework. This approach is applicable to a wide variety of problems to study linked gray and white matter group differences.

  12. Joint source based morphometry identifies linked gray and white matter group differences

    PubMed Central

    Xu, Lai; Pearlson, Godfrey; Calhoun, Vince D.

    2009-01-01

    We present a multivariate approach called joint source based morphometry (jSBM), to identify linked gray and white matter regions which differ between groups. In jSBM, joint independent component analysis (jICA) is used to decompose preprocessed gray and white matter images into joint sources and statistical analysis is used to determine the significant joint sources showing group differences and their relationship to other variables of interest (e.g. age or sex). The identified joint sources are groupings of linked gray and white matter regions with common covariation among subjects. In this study, we first provide a simulation to validate the jSBM approach. To illustrate our method on real data, jSBM is then applied to structural magnetic resonance imaging (sMRI) data obtained from 120 chronic schizophrenia patients and 120 healthy controls to identify group differences. JSBM identified four joint sources as significantly associated with schizophrenia. Linked gray–white matter regions identified in each of the joint sources included: 1) temporal — corpus callosum, 2) occipital/frontal — inferior fronto-occipital fasciculus, 3) frontal/parietal/occipital/temporal —superior longitudinal fasciculus and 4) parietal/frontal — thalamus. Age effects on all four joint sources were significant, but sex effects were significant only for the third joint source. Our findings demonstrate that jSBM can exploit the natural linkage between gray and white matter by incorporating them into a unified framework. This approach is applicable to a wide variety of problems to study linked gray and white matter group differences. PMID:18992825

  13. 9. DETAIL VIEW OF ROLLING EXPANSION JOINT, NORTHEAST BASE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. DETAIL VIEW OF ROLLING EXPANSION JOINT, NORTHEAST BASE OF SECOND CLOSED SPANDREL ARCH AT JUNCTION OF OPEN SPANDREL ARCH, LOOKING EAST - Virgin River Bridge, Spanning Virgin River on State Highway 9, Hurricane, Washington County, UT

  14. Some logical functions of joint control.

    PubMed Central

    Lowenkron, B

    1998-01-01

    Constructing a behavioral account of the language-related performances that characterize responding to logical and symbolic relations between stimuli is commonly viewed as a problem for the area of stimulus control. In response to this problem, the notion of joint control is presented here, and its ability to provide an interpretative account of these kinds of performances is explored. Joint control occurs when the currently rehearsed topography of a verbal operant, as evoked by one stimulus, is simultaneously evoked by another stimulus. This event, the onset of joint stimulus control by two stimuli over a common response topography, then sets the occasion for a response appropriate to this special relation between the stimuli. Although the mechanism described is simple, it seems to have broad explanatory properties. In what follows, these properties are applied to provide a behavioral interpretation of two sorts of fundamental, putatively cognitive, performances: those based on logical relations and those based on semantic relations. The first includes responding to generalized conceptual relations such as identity, order, relative size, distance, and orientation. The second includes responding to relations usually ascribed to word meaning. These include relations between words and objects, the specification of objects by words, name-object bidirectionality, and the recognition of objects from their description. Finally, as a preview of some further possibilities, the role of joint control in goal-oriented behavior is considered briefly. PMID:9599452

  15. Thermally Conductive Metal-Tube/Carbon-Composite Joints

    NASA Technical Reports Server (NTRS)

    Copeland, Robert J.

    2004-01-01

    An improved method of fabricating joints between metal and carbon-fiber-based composite materials in lightweight radiators and heat sinks has been devised. Carbon-fiber-based composite materials have been used in such heat-transfer devices because they offer a combination of high thermal conductivity and low mass density. Metal tubes are typically used to carry heat-transfer fluids to and from such heat-transfer devices. The present fabrication method helps to ensure that the joints between the metal tubes and the composite-material parts in such heat-transfer devices have both (1) the relatively high thermal conductances needed for efficient transfer of heat and (2) the flexibility needed to accommodate differences among thermal expansions of dissimilar materials in operation over wide temperature ranges. Techniques used previously to join metal tubes with carbon-fiber-based composite parts have included press fitting and bonding with epoxy. Both of these prior techniques have been found to yield joints characterized by relatively high thermal resistances. The present method involves the use of a solder (63 percent Sn, 37 percent Pb) to form a highly thermally conductive joint between a metal tube and a carbon-fiber-based composite structure. Ordinarily, the large differences among the coefficients of thermal expansion of the metal tube, solder, and carbon-fiber-based composite would cause the solder to pull away from the composite upon post-fabrication cooldown from the molten state. In the present method, the structure of the solder is modified (see figure) to enable it to deform readily to accommodate the differential thermal expansion.

  16. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  17. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    PubMed

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  18. Operational space weather product development and validation at the joint SMC-AFRL Rapid Prototyping Center

    NASA Astrophysics Data System (ADS)

    Quigley, S.

    The Air Force Research Laboratory (AFRL/VSB) and Detachment 11, Space &Missile Systems Center (SMC, Det 11/CIT) have combined efforts to design, develop, test, and implement graphical products for the Air Force's space weather operations center. These products are generated to analyze, specify, and forecast the effects of the near-earth space environment on Department of Defense systems and communications. Jointly-developed products that have been, or will soon be added to real-time operations include: 1) the Operational Space Environment Network Display (OpSEND) suit - a set of four products that address HF communication, UHF satellite communication scintillation, radar auroral clutter, and GP S single- frequency errors; 2) a solar radio background and burst effects (SoRBE) product suite; and C) a meteor effects (ME) product suite. The RPC is also involved in a rather substantial "V&V" effort to produce multiple operational product verifications and validations, with an added end goal of a generalized validation software package. The presentation will provide a general overview of the RPC and each of the products mentioned above, to include background science, operational history, inputs, outputs, dissemination, and customer uses for each.

  19. 14 CFR 119.47 - Maintaining a principal base of operations, main operations base, and main maintenance base...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Maintaining a principal base of operations, main operations base, and main maintenance base; change of address. 119.47 Section 119.47 Aeronautics... Under Part 121 or Part 135 of This Chapter § 119.47 Maintaining a principal base of operations, main...

  20. 14 CFR 119.47 - Maintaining a principal base of operations, main operations base, and main maintenance base...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Maintaining a principal base of operations, main operations base, and main maintenance base; change of address. 119.47 Section 119.47 Aeronautics... Under Part 121 or Part 135 of This Chapter § 119.47 Maintaining a principal base of operations, main...

  1. 14 CFR 119.47 - Maintaining a principal base of operations, main operations base, and main maintenance base...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Maintaining a principal base of operations, main operations base, and main maintenance base; change of address. 119.47 Section 119.47 Aeronautics... Under Part 121 or Part 135 of This Chapter § 119.47 Maintaining a principal base of operations, main...

  2. 14 CFR 119.47 - Maintaining a principal base of operations, main operations base, and main maintenance base...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Maintaining a principal base of operations, main operations base, and main maintenance base; change of address. 119.47 Section 119.47 Aeronautics... Under Part 121 or Part 135 of This Chapter § 119.47 Maintaining a principal base of operations, main...

  3. Joint sparse reconstruction of multi-contrast MRI images with graph based redundant wavelet transform.

    PubMed

    Lai, Zongying; Zhang, Xinlin; Guo, Di; Du, Xiaofeng; Yang, Yonggui; Guo, Gang; Chen, Zhong; Qu, Xiaobo

    2018-05-03

    Multi-contrast images in magnetic resonance imaging (MRI) provide abundant contrast information reflecting the characteristics of the internal tissues of human bodies, and thus have been widely utilized in clinical diagnosis. However, long acquisition time limits the application of multi-contrast MRI. One efficient way to accelerate data acquisition is to under-sample the k-space data and then reconstruct images with sparsity constraint. However, images are compromised at high acceleration factor if images are reconstructed individually. We aim to improve the images with a jointly sparse reconstruction and Graph-based redundant wavelet transform (GBRWT). First, a sparsifying transform, GBRWT, is trained to reflect the similarity of tissue structures in multi-contrast images. Second, joint multi-contrast image reconstruction is formulated as a ℓ 2, 1 norm optimization problem under GBRWT representations. Third, the optimization problem is numerically solved using a derived alternating direction method. Experimental results in synthetic and in vivo MRI data demonstrate that the proposed joint reconstruction method can achieve lower reconstruction errors and better preserve image structures than the compared joint reconstruction methods. Besides, the proposed method outperforms single image reconstruction with joint sparsity constraint of multi-contrast images. The proposed method explores the joint sparsity of multi-contrast MRI images under graph-based redundant wavelet transform and realizes joint sparse reconstruction of multi-contrast images. Experiment demonstrate that the proposed method outperforms the compared joint reconstruction methods as well as individual reconstructions. With this high quality image reconstruction method, it is possible to achieve the high acceleration factors by exploring the complementary information provided by multi-contrast MRI.

  4. The Joint Master Operational Planner

    DTIC Science & Technology

    2016-04-04

    Operational Planner Program, that will produce planners that are able to understand the strategic- operational environment, properly advise commanders, and...Planner Program, that will produce planners that are able to understand the strategic-operational environment, properly advise commanders, and devise...states struggle to exercise even nominal power within their borders, and the people see the government as an entity that seeks only to keep itself in

  5. Thumb carpometacarpal joint resurfacing with autologous ear cartilage.

    PubMed

    Nickell, William B

    2014-05-01

    A study was designed to ascertain the long-term effectiveness of using autologous full-thickness ear cartilage to resurface the arthritic face of the trapezium, leaving the body of the trapezium intact. The value of injection of the involved carpometacarpal (CMC) joint with local anesthetic in predicting improvement from the surgery was also studied. An operation was used to enter the CMC joint of the thumb between the thenar muscles and the abductor tendon. The articular surface of the trapezium was resected and resurfaced with full-thickness ear cartilage from the patient's ear. Patients were selected based on constant, unremitting pain. All patients also had x-ray evidence of severe arthritis at the CMC joint of the thumb. Both thumbs were evaluated for pain, range of motion, key and palmar pinch, and grip strength before the surgery and followed up for a minimum of 30 months to be included in the study. Fifty-nine patients had ear cartilage arthroplasty from 1997 to 2007 by the same surgeon with a total of 67 operations (8 patients, all women, had both thumbs operated). Forty-nine of these patients, 4 men and 45 women (53 hands), were available for follow-up and constitute the study group. Eight procedures were done on the left hand, and 45, on the right. There were no ear complications and no cartilage extrusions. All patients had improved range of motion and greatly decreased pain. Strength was equaled or exceeded the unoperated thumb. Preoperative joint injection was a good predictor of postoperative pain relief. All patients were pleased with the result and said that they would have the surgery again. Thumb CMC joint arthroplasty with autologous ear cartilage and preservation of the body of the trapezium is an effective alternative to existing procedures.There is no morbidity to the ear, and predictable long-term improvement in thumb pain and strength can be obtained. Injection of the CMC joint before surgery with local anesthetic is a reliable predictor of

  6. Joint source based analysis of multiple brain structures in studying major depressive disorder

    NASA Astrophysics Data System (ADS)

    Ramezani, Mahdi; Rasoulian, Abtin; Hollenstein, Tom; Harkness, Kate; Johnsrude, Ingrid; Abolmaesumi, Purang

    2014-03-01

    We propose a joint Source-Based Analysis (jSBA) framework to identify brain structural variations in patients with Major Depressive Disorder (MDD). In this framework, features representing position, orientation and size (i.e. pose), shape, and local tissue composition are extracted. Subsequently, simultaneous analysis of these features within a joint analysis method is performed to generate the basis sources that show signi cant di erences between subjects with MDD and those in healthy control. Moreover, in a cross-validation leave- one-out experiment, we use a Fisher Linear Discriminant (FLD) classi er to identify individuals within the MDD group. Results show that we can classify the MDD subjects with an accuracy of 76% solely based on the information gathered from the joint analysis of pose, shape, and tissue composition in multiple brain structures.

  7. Fatigue Strength Estimation Based on Local Mechanical Properties for Aluminum Alloy FSW Joints

    PubMed Central

    Sillapasa, Kittima; Mutoh, Yoshiharu; Miyashita, Yukio; Seo, Nobushiro

    2017-01-01

    Overall fatigue strengths and hardness distributions of the aluminum alloy similar and dissimilar friction stir welding (FSW) joints were determined. The local fatigue strengths as well as local tensile strengths were also obtained by using small round bar specimens extracted from specific locations, such as the stir zone, heat affected zone, and base metal. It was found from the results that fatigue fracture of the FSW joint plate specimen occurred at the location of the lowest local fatigue strength as well as the lowest hardness, regardless of microstructural evolution. To estimate the fatigue strengths of aluminum alloy FSW joints from the hardness measurements, the relationship between fatigue strength and hardness for aluminum alloys was investigated based on the present experimental results and the available wide range of data from the references. It was found as: σa (R = −1) = 1.68 HV (σa is in MPa and HV has no unit). It was also confirmed that the estimated fatigue strengths were in good agreement with the experimental results for aluminum alloy FSW joints. PMID:28772543

  8. Fatigue Strength Estimation Based on Local Mechanical Properties for Aluminum Alloy FSW Joints.

    PubMed

    Sillapasa, Kittima; Mutoh, Yoshiharu; Miyashita, Yukio; Seo, Nobushiro

    2017-02-15

    Overall fatigue strengths and hardness distributions of the aluminum alloy similar and dissimilar friction stir welding (FSW) joints were determined. The local fatigue strengths as well as local tensile strengths were also obtained by using small round bar specimens extracted from specific locations, such as the stir zone, heat affected zone, and base metal. It was found from the results that fatigue fracture of the FSW joint plate specimen occurred at the location of the lowest local fatigue strength as well as the lowest hardness, regardless of microstructural evolution. To estimate the fatigue strengths of aluminum alloy FSW joints from the hardness measurements, the relationship between fatigue strength and hardness for aluminum alloys was investigated based on the present experimental results and the available wide range of data from the references. It was found as: σ a ( R = -1) = 1.68 HV ( σ a is in MPa and HV has no unit). It was also confirmed that the estimated fatigue strengths were in good agreement with the experimental results for aluminum alloy FSW joints.

  9. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer E.; Aitchison, Lindsay

    2009-01-01

    A space suit s mobility is critical to an astronaut s ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. The term mobility, with respect to space suits, is defined in terms of two key components: joint range of motion and joint torque. Individually these measures describe the path which in which a joint travels and the force required to move it through that path. Previous space suits mobility requirements were defined as the collective result of these two measures and verified by the completion of discrete functional tasks. While a valid way to impose mobility requirements, such a method does necessitate a solid understanding of the operational scenarios in which the final suit will be performing. Because the Constellation space suit system requirements are being finalized with a relatively immature concept of operations, the Space Suit Element team elected to define mobility in terms of its constituent parts to increase the likelihood that the future pressure garment will be mobile enough to enable a broad scope of undefined exploration activities. The range of motion requirements were defined by measuring the ranges of motion test subjects achieved while performing a series of joint maximizing tasks in a variety of flight and prototype space suits. The definition of joint torque requirements has proved more elusive. NASA evaluated several different approaches to the problem before deciding to generate requirements based on unmanned joint torque evaluations of six different space suit configurations being articulated through 16 separate joint movements. This paper discusses the experiment design, data analysis and results, and the process used to determine the final values for the Constellation pressure garment joint torque requirements.

  10. Refinement of the β-Sn Grains in Ni-Doped Sn-3.0Ag-0.5Cu Solder Joints with Cu-Based and Ni-Based Substrates

    NASA Astrophysics Data System (ADS)

    Chou, Tzu-Ting; Chen, Wei-Yu; Fleshman, Collin Jordon; Duh, Jenq-Gong

    2018-03-01

    A fine-grain structure with random orientations of lead-free solder joints was successfully obtained in this study. The Sn-Ag-Cu solder alloys doped with minor Ni were reflowed with Ni-based or Cu-based substrates to fabricate the joints containing different Ni content. Adding 0.1 wt.% Ni into the solder effectively promoted the formation of fine Sn grains, and reflowing with Ni-based substrates further enhanced the effects of β-Sn grain refinement. The crystallographic characteristics and the microstructures were analyzed to identify the solidification mechanism of different types of microstructure in the joints. The phase precipitating order in the joint altered as the solder composition were modified by elemental doping and changing substrate, which significantly affected the efficiency of grain refinement and the final grain structure. The formation mechanism of fine β-Sn grains in the Ni-doped joint with a Ni-based substrate is attributable to the heterogeneous nucleation by Ni, whereas the Ni in the joint using ChouCu-based substrate is consumed to form an intermetallic compound and thus retard the effect of grain refining.

  11. Neural joint control for Space Shuttle Remote Manipulator System

    NASA Technical Reports Server (NTRS)

    Atkins, Mark A.; Cox, Chadwick J.; Lothers, Michael D.; Pap, Robert M.; Thomas, Charles R.

    1992-01-01

    Neural networks are being used to control a robot arm in a telerobotic operation. The concept uses neural networks for both joint and inverse kinematics in a robotic control application. An upper level neural network is trained to learn inverse kinematic mappings. The output, a trajectory, is then fed to the Decentralized Adaptive Joint Controllers. This neural network implementation has shown that the controlled arm recovers from unexpected payload changes while following the reference trajectory. The neural network-based decentralized joint controller is faster, more robust and efficient than conventional approaches. Implementations of this architecture are discussed that would relax assumptions about dynamics, obstacles, and heavy loads. This system is being developed to use with the Space Shuttle Remote Manipulator System.

  12. Joint Communications in Support of Joint Task Force South during Operation Just Cause

    DTIC Science & Technology

    1991-01-01

    the contingent frcm the 35th Signal Brigade under Colonel Jackson Moss arrived at Howard Air Force Base in a C-5A Galaxy . Colonel Moss had put together...to be an operation of short duration with the flowing in of one follow on Brigade of the 7th ID and the immediate redeployment of the Rangers and the

  13. Reporters on the Ground: The Military and the Media’s Joint Experience During Operation Iraqi Freedom

    DTIC Science & Technology

    2003-10-01

    field into a larger context. Conversely, those TV journalists supplying these spectacular reports and engrossing pictures from the front line were also... journalists , soldiers, and marines together in the same environment. Under such circumstances, whether reporters can or cannot be objective may be...H I P October 2003 Volume 08-03 REPORTERS ON THE GROUND: The Military and the Media’s Joint Experience During Operation Iraqi Freedom By

  14. [Comparative evolution surgical accesses to temporo-mandibular joint].

    PubMed

    Sysoliatin, P G; Novikov, A I; Sysoliatin, S P; Bobylev, N G; Brega, I N

    2007-01-01

    In experiment on 30 corpses of adult people criteria of an operational wound (depth of a wound, a corner of operational action, an axis of operational action, a corner of an inclination of operational action) were studied at preauricularis, intrauricularis, intrauriculo-temporalis and posterior mandibullaris access to temporo-mandibular joint (TMJ). New surgical intrauriculo-temporalis access to the joint is substantrated. On the basis of the analysis of 289 operations at 268 patients the indications to a choice of surgical access were developed at various diseases and damages of TMJ.

  15. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    PubMed

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  16. Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception

    PubMed Central

    Mourcou, Quentin; Fleury, Anthony; Diot, Bruno; Franco, Céline; Vuillerme, Nicolas

    2015-01-01

    Assessment of joint functional and proprioceptive abilities is essential for balance, posture, and motor control rehabilitation. Joint functional ability refers to the capacity of movement of the joint. It may be evaluated thereby measuring the joint range of motion (ROM). Proprioception can be defined as the perception of the position and of the movement of various body parts in space. Its role is essential in sensorimotor control for movement acuity, joint stability, coordination, and balance. Its clinical evaluation is commonly based on the assessment of the joint position sense (JPS). Both ROM and JPS measurements require estimating angles through goniometer, scoliometer, laser-pointer, and bubble or digital inclinometer. With the arrival of Smartphones, these costly clinical tools tend to be replaced. Beyond evaluation, maintaining and/or improving joint functional and proprioceptive abilities by training with physical therapy is important for long-term management. This review aims to report Smartphone applications used for measuring and improving functional and proprioceptive abilities. It identifies that Smartphone applications are reliable for clinical measurements and are mainly used to assess ROM and JPS. However, there is lack of studies on Smartphone applications which can be used in an autonomous way to provide physical therapy exercises at home. PMID:26583101

  17. Experimental Robot Position Sensor Fault Tolerance Using Accelerometers and Joint Torque Sensors

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    Robot systems in critical applications, such as those in space and nuclear environments, must be able to operate during component failure to complete important tasks. One failure mode that has received little attention is the failure of joint position sensors. Current fault tolerant designs require the addition of directly redundant position sensors which can affect joint design. The proposed method uses joint torque sensors found in most existing advanced robot designs along with easily locatable, lightweight accelerometers to provide a joint position sensor fault recovery mode. This mode uses the torque sensors along with a virtual passive control law for stability and accelerometers for joint position information. Two methods for conversion from Cartesian acceleration to joint position based on robot kinematics, not integration, are presented. The fault tolerant control method was tested on several joints of a laboratory robot. The controllers performed well with noisy, biased data and a model with uncertain parameters.

  18. Single stage treatment of ankylosis of the temporomandibular joint using patient-specific total joint replacement and virtual surgical planning.

    PubMed

    Haq, Jahrad; Patel, Nishma; Weimer, Katherine; Matthews, N Shaun

    2014-04-01

    Ankylosis of the temporomandibular joint (TMJ) is a debilitating condition that can result in pain, trismus, and a poor quality of life. It can be caused by injury, infection, and rheumatoid disease. Current management includes gap arthroplasty, interpositional arthroplasty, and reconstruction. Traditionally, joints are reconstructed using stock implants, or the procedure is done in two stages with an additional computed tomography (CT) scan between the resective and reconstructive procedures and use of stereolithographic models to aid the design of the definitive prostheses. We describe a technique for the resection of ankylosis and reconstruction of the joint in a single operation using virtually designed custom-made implants. Five patients with ankylosis of the TMJ had a single stage operation with reconstruction between 2010 and 2012. All had preoperative high-resolution CT with contrast angiography. During an international web-based teleconference between the surgeon and the engineer a virtual resection of the ankylosis was done using the reconstructed CT images. The bespoke cutting guides and implants were designed virtually at the same time and were then manufactured precisely using computer-aided design and manufacture (CAD-CAM) over 6 weeks. After release of the ankylosis and reconstruction, the patients underwent an exercise regimen to improve mouth opening. Follow-up was for a minimum of 6 months. Four patients had one operation, and one patient had two. Median/Mean maximum incisal opening increased from 0.6mm before operation to 25 mm afterwards (range 23-27), and there was minimal surgical morbidity. This new method effectively treats ankylosis of the TMJ in a single stage procedure. Fewer operations and hospital stays, and the maintenance of overall clinical outcome are obvious advantages. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  19. Lumbar joint torque estimation based on simplified motion measurement using multiple inertial sensors.

    PubMed

    Miyajima, Saori; Tanaka, Takayuki; Imamura, Yumeko; Kusaka, Takashi

    2015-01-01

    We estimate lumbar torque based on motion measurement using only three inertial sensors. First, human motion is measured by a 6-axis motion tracking device that combines a 3-axis accelerometer and a 3-axis gyroscope placed on the shank, thigh, and back. Next, the lumbar joint torque during the motion is estimated by kinematic musculoskeletal simulation. The conventional method for estimating joint torque uses full body motion data measured by an optical motion capture system. However, in this research, joint torque is estimated by using only three link angles of the body, thigh, and shank. The utility of our method was verified by experiments. We measured motion of bendung knee and waist simultaneously. As the result, we were able to estimate the lumbar joint torque from measured motion.

  20. Broadband rotary joint for high speed ultrahigh resolution endoscopic OCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alemohammad, Milad; Yuan, Wu; Mavadia-Shukla, Jessica; Liang, Wenxuan; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde

    2016-03-01

    Endoscopic OCT is a promising technology enabling noninvasive in vivo imaging of internal organs, such as the gastrointestinal tract and airways. The past few years have witnessed continued efforts to achieve ultrahigh resolution and speed. It is well-known that the axial resolution in OCT imaging has a quadratic dependence on the central wavelength. While conventional OCT endoscopes operate in 1300 nm wavelength, the second-generation endoscopes are designed for operation around 800 nm where turn-key, broadband sources are becoming readily available. Traditionally 1300 nm OCT endoscopes are scanned at the proximal end, and a broadband fiber-optic rotary joint as a key component in scanning endoscopic OCT is commercially available. Bandwidths in commercial 800 nm rotary joints are unfortunately compromised due to severe chromatic aberration, which limits the resolution afforded by the broadband light source. In the past we remedied this limitation by using a home-made capillary-tube-based rotary joint where the maximum reliable speed is ~10 revolutions/second. In this submission we report our second-generation, home-built high-speed and broadband rotary joint for 800 nm wavelength, which uses achromatic doublets in order achieve broadband achromatic operation. The measured one-way throughput of the rotary joint is >67 % while the fluctuation of the double-pass coupling efficiency during 360° rotation is less than +/-5 % at a speed of 70 revolutions/second. We demonstrate the operation of this rotary joint in conjunction with our ultrahigh-resolution (2.4 µm in air) diffractive catheter by three-dimensional full-circumferential endoscopic imaging of guinea pig esophagus at 70 frames per second in vivo.

  1. Mechanical end joint system for connecting structural column elements

    NASA Technical Reports Server (NTRS)

    Bush, Harold G. (Inventor); Mikulas, Martin M., Jr. (Inventor); Wallsom, Richard E. (Inventor)

    1990-01-01

    A mechanical end joint system is presented that eliminates the possibility of free movements between the joint halves during loading or vibration. Both node joint body (NJB) and column end joint body (CEJB) have cylindrical engaging ends. Each of these ends has an integral semicircular tongue and groove. The two joint halves are engaged transversely - the tongue of the NJB mating with the groove of the CEJB and vice versa. The joint system employs a spring loaded internal latch mechanism housed in the CEJB. During mating, this mechanism is pushed away from the NJB and enters the NJB when mating is completed. In order to lock the joint and add a preload across the tongue and groove faces, an operating ring collar is rotated through 45 deg causing an internal mechanism to compress a Belleville washer preload mechanism. This causes an equal and opposite force to be exerted on the latch bolt and the latch plunger. This force presses the two joint halves tightly together. In order to prevent inadvertent disassembly, a secondary lock is also engaged when the joint is closed. Plungers are carried in the operating ring collar. When the joint is closed, the plungers fall into tracks on the CEJB, which allows the joint to be opened only when the operating ring collar and plungers are pushed directly away from the joining end. One application of this invention is the rapid assembly and disassembly of diverse skeletal framework structures which is extremely important in many projects involving the exploration of space.

  2. Pre-operative intra-articular deep tissue sampling with novel retrograde forceps improves the diagnostics in periprosthetic joint infection.

    PubMed

    Wimmer, Matthias D; Ploeger, Milena M; Friedrich, Max J; Hügle, Thomas; Gravius, Sascha; Randau, Thomas M

    2017-07-01

    Histopathological tissue analysis is a key parameter within the diagnostic algorithm for suspected periprosthetic joint infections (PJIs), conventionally acquired in open surgery. In 2014, Hügle and co-workers introduced novel retrograde forceps for retrograde synovial biopsy with simultaneous fluid aspiration of the knee joint. We hypothesised that tissue samples acquired by retrograde synovial biopsy are equal to intra-operatively acquired deep representative tissue samples regarding bacterial detection and differentiation of periprosthetic infectious membranes. Thirty patients (male n = 15, 50%; female n = 15, 50%) with 30 suspected PJIs in painful total hip arthroplasties (THAs) were included in this prospective, controlled, non-blinded trial. The results were compared with intra-operatively obtained representative deep tissue samples. In summary, 27 out of 30 patients were diagnosed correctly as infected (17/17) or non-infected (10/13). The sensitivity to predict a PJI using the Retroforce® sampling forceps in addition to standard diagnostics was 85%, the specificity 100%. Retrograde synovial biopsy is a new and rapid diagnostic procedure under local anaesthesia in patients with painful THAs with similar histological results compared to deep tissue sampling.

  3. Joint Airspace Control, Doctrine Update 10-06

    DTIC Science & Technology

    2010-05-20

    Doctrine Update 10-06 Joint Publication 3-52, Joint Airspace Control JP 3-52 provides joint doctrine for airspace control across the full range...identification, combined operations, and unmanned aerial vehicle If you want read the complete new doctrine document, dated 20 May 2010, click here: JP 3-52...Joint Airspace Control. For more information, visit the LeMay Center for Doctrine Development and Education, call us at DSN 493-7442, or e-mail

  4. Apollo Soyuz mission planning and operations

    NASA Technical Reports Server (NTRS)

    Frank, M. P., III

    1976-01-01

    The paper describes the Apollo Soyuz project from the points of view of working group organization, mission plan definition, joint operations concept, and mission preparation. The concept for joint operations considered contingency situations as well as nominal operations. Preparations for the joint flight included cooperative tracking tests and combined training of the flight crews and mission control personnel.

  5. [Case-control study on measurement of coracoclavicular and acromioclavicular ligament injuries during internal fixation operation for the treatment of fresh acromioclavicular joint dislocation of Tossy type III].

    PubMed

    Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang

    2014-01-01

    To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged

  6. A joint tracking method for NSCC based on WLS algorithm

    NASA Astrophysics Data System (ADS)

    Luo, Ruidan; Xu, Ying; Yuan, Hong

    2017-12-01

    Navigation signal based on compound carrier (NSCC), has the flexible multi-carrier scheme and various scheme parameters configuration, which enables it to possess significant efficiency of navigation augmentation in terms of spectral efficiency, tracking accuracy, multipath mitigation capability and anti-jamming reduction compared with legacy navigation signals. Meanwhile, the typical scheme characteristics can provide auxiliary information for signal synchronism algorithm design. This paper, based on the characteristics of NSCC, proposed a kind of joint tracking method utilizing Weighted Least Square (WLS) algorithm. In this method, the LS algorithm is employed to jointly estimate each sub-carrier frequency shift with the frequency-Doppler linear relationship, by utilizing the known sub-carrier frequency. Besides, the weighting matrix is set adaptively according to the sub-carrier power to ensure the estimation accuracy. Both the theory analysis and simulation results illustrate that the tracking accuracy and sensitivity of this method outperforms the single-carrier algorithm with lower SNR.

  7. Relationship between patellar mobility and patellofemoral joint cartilage degeneration after anterior cruciate ligament reconstruction.

    PubMed

    Ota, Susumu; Kurokouchi, Kazutoshi; Takahashi, Shigeo; Yoda, Masaki; Yamamoto, Ryuichiro; Sakai, Tadahiro

    2017-11-01

    Patellofemoral cartilage degeneration is a potential complication of anterior cruciate ligament reconstruction (ACLR) surgery. Hypomobility of the patella in the coronal plane is often observed after ACLR. Few studies, however, have examined the relationship between cartilage degeneration in the patellofemoral joint and mobility after ACLR. The present study investigated 1) the coronal mobility of the patella after ACLR, 2) the relationship between patellar mobility and cartilage degeneration of the patellofemoral joint, and 3) the relationship between patellar mobility and knee joint function after ACLR. Forty patients who underwent medial hamstring-based ACLR participated in the study. Lateral and medial patellar displacements were assessed with a modified patellofemoral arthrometer, and the absolute values of the displacements were normalized to patient height. The International Cartilage Repair Society (ICRS) cartilage injury classification of the patellar and femoral (trochlear) surfaces, and the Lysholm Knee Scoring Scale were used to evaluate knee function. Lateral and medial patellar displacements were reduced compared with the non-operated knee at the second-look arthroscopy and bone staple extraction operation (second operation; 24.4 ± 7.9 months after ACLR, P<0.01). The ICRS grades of the patellofemoral joint (patella and trochlea) were significantly worse than those pre-ACLR. Neither lateral nor medial patellar mobility, however, were significantly correlated with the ICRS grade or the Lysholm score. Although patellar mobility at approximately 2 years after ACLR was decreased compared to the non-operated knee, small displacement of the patella was not related to cartilage degeneration or knee joint function at the time of the second operation.

  8. Final Environmental Assessment: Solar Panel Systems at Joint Base McGuire-Dix-Lakehurst New Jersey

    DTIC Science & Technology

    2012-03-01

    FINAL ENVIRONMENTAL ASSESSMENT Solar Panel Systems at Joint Base McGuire-Dix-Lakehurst, New Jersey MARCH 2012...Final Environmental Assessment : Solar Panel Systems at Joint Base McGuire-Dix-Lakehurst New Jersey 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Purpose Finding of No Significant Impact (FONSI) Environmental Assessment (EA

  9. Mapping the Future: Optimizing Joint Geospatial Engineering Support

    DTIC Science & Technology

    2006-05-16

    Environment. Maxwell Air Force Base, AL.: Air University, 1990. Babbage , Ross and Desmond Ball. Geographic Information Systems: Defence Applications...Joint Pub 4-04. Washington, DC: 27 September 2001. Wertz, Charles J. The Data Dictionary, Concepts and Uses. Wellesley, MA: QED Information...Force Defense Mapping for Future Operations, Washington, DC: September 1995, 1-7. 18 Charles J. Wertz, The Data Dictionary, Concepts and Uses

  10. Lamb Wave-Based Structural Health Monitoring on Composite Bolted Joints under Tensile Load

    PubMed Central

    Yang, Bin; Xuan, Fu-Zhen; Xiang, Yanxun; Li, Dan; Zhu, Wujun; Tang, Xiaojun; Xu, Jichao; Yang, Kang; Luo, Chengqiang

    2017-01-01

    Online and offline monitoring of composite bolted joints under tensile load were investigated using piezoelectric transducers. The relationships between Lamb wave signals, pre-tightening force, the applied tensile load, as well as the failure modes were investigated. Results indicated that S0/A0 wave amplitudes decrease with the increasing of load. Relationships between damage features and S0/A0 mode were built based on the finite element (FE) simulation and experimental results. The possibility of application of Lamb wave-based structure health monitoring in bolted joint-like composite structures was thus achieved. PMID:28773014

  11. [Sacroiliac joint dysfunction with groin pain after an operation for lumbar spinal disorder. A case report].

    PubMed

    Shimoda, Yusuke; Morimoto, Daijiro; Isu, Toyohiko; Motegi, Hiroaki; Imai, Tetsuaki; Matsumoto, Ryouji; Isobe, Masanori; Kim, Kyongsong; Sugawara, Atsushi

    2010-11-01

    A 75-year-old male presented with groin pain after an operation to treat lumbar spondylolisthesis (L5). Groin tenderness was localized to the medial border of the anterior superior iliac spine (ASIS). Radiographical and physical examination raised the suspicion of sacroiliac joint (SIJ) dysfunction. Injection of a painkiller into the SIJ relieved symptoms, including groin tenderness. Symptoms improved gradually, and finally disappeared after five SIJ injections. Groin pain has been reported as a referred symptom of SIJ dysfunction in 9.3-23% of patients. Prior to the patient undergoing surgery to treat lumbar spondylolisthesis, SIJ dysfunction had not been noted on physical examination. Long periods spent in the abnormal posture due to lumbar spondylolisthesis induced SIJ stress. After the operation, an improvement in daily activity actually increased stress on the SIJ, resulting in SIJ dysfunction. Certain pathologies, including SIJ dysfunction, should be considered as residual symptoms after operations for lumbar spinal diseases.

  12. Quantification of cardiorespiratory interactions based on joint symbolic dynamics.

    PubMed

    Kabir, Muammar M; Saint, David A; Nalivaiko, Eugene; Abbott, Derek; Voss, Andreas; Baumert, Mathias

    2011-10-01

    Cardiac and respiratory rhythms are highly nonlinear and nonstationary. As a result traditional time-domain techniques are often inadequate to characterize their complex dynamics. In this article, we introduce a novel technique to investigate the interactions between R-R intervals and respiratory phases based on their joint symbolic dynamics. To evaluate the technique, electrocardiograms (ECG) and respiratory signals were recorded in 13 healthy subjects in different body postures during spontaneous and controlled breathing. Herein, the R-R time series were extracted from ECG and respiratory phases were obtained from abdomen impedance belts using the Hilbert transform. Both time series were transformed into ternary symbol vectors based on the changes between two successive R-R intervals or respiratory phases. Subsequently, words of different symbol lengths were formed and the correspondence between the two series of words was determined to quantify the interaction between cardiac and respiratory cycles. To validate our results, respiratory sinus arrhythmia (RSA) was further studied using the phase-averaged characterization of the RSA pattern. The percentage of similarity of the sequence of symbols, between the respective words of the two series determined by joint symbolic dynamics, was significantly reduced in the upright position compared to the supine position (26.4 ± 4.7 vs. 20.5 ± 5.4%, p < 0.01). Similarly, RSA was also reduced during upright posture, but the difference was less significant (0.11 ± 0.02 vs. 0.08 ± 0.01 s, p < 0.05). In conclusion, joint symbolic dynamics provides a new efficient technique for the analysis of cardiorespiratory interaction that is highly sensitive to the effects of orthostatic challenge.

  13. Model-Based Estimation of Ankle Joint Stiffness

    PubMed Central

    Misgeld, Berno J. E.; Zhang, Tony; Lüken, Markus J.; Leonhardt, Steffen

    2017-01-01

    We address the estimation of biomechanical parameters with wearable measurement technologies. In particular, we focus on the estimation of sagittal plane ankle joint stiffness in dorsiflexion/plantar flexion. For this estimation, a novel nonlinear biomechanical model of the lower leg was formulated that is driven by electromyographic signals. The model incorporates a two-dimensional kinematic description in the sagittal plane for the calculation of muscle lever arms and torques. To reduce estimation errors due to model uncertainties, a filtering algorithm is necessary that employs segmental orientation sensor measurements. Because of the model’s inherent nonlinearities and nonsmooth dynamics, a square-root cubature Kalman filter was developed. The performance of the novel estimation approach was evaluated in silico and in an experimental procedure. The experimental study was conducted with body-worn sensors and a test-bench that was specifically designed to obtain reference angle and torque measurements for a single joint. Results show that the filter is able to reconstruct joint angle positions, velocities and torque, as well as, joint stiffness during experimental test bench movements. PMID:28353683

  14. The Command and Control of Communications in Joint and Combined Operations

    DTIC Science & Technology

    1994-06-03

    war. The Joint Task Force structure is used as the model for command and control relationships . The first part of the thesis assesses the current...Joint Task Force structure is used as the model for conmand and control relationships . The first part of the thesis assesses the current doctrine and...Message Switch Connectivity . . . . . . . 59 10. C4 Architecture Requirements . . . . . . 81 11. Functional Relationships . . . . . . 84 vi LIST OF

  15. Operative tactics and results of treatment of patients with coxarthrosis secondary to congenital high luxation of hip joints.

    PubMed

    Król, Roman; Rojewski, Marek; Kamiński, Adam; Popławski, Tomasz

    2007-01-01

    Treatment of the sequelae of congenital high luxation of the hip joint is a major challenge in prosthetic surgery, demanding from the operator thorough familiarity with the problem and experience in hop reconstructive surgery. The results of 4 years observation, of the treatment of 14 woman in the average age of 38 years old with 18 hip joints with congenital high luxation are presented. In all cases cementless total hip arthroplasty was made. Acetabular component of the prosthesis was implanted correctly and stable in its physiological placement. Femur was shortened average 4 cm and stabilized by cementless press-fit stem of prosthesis. The place of femur osteotomy was covered with autogenic spongy bone from resected caput of femur. The union was achieved after average 10 weeks. In clinical assessment there were obtained 10 very good, 5 good and 3 satisfactory clinical results. There were no superficial or deep infections, no neurological disorders and no loosening of components of implanted prostheses observed. 1. Careful planning and carrying out the operative procedures allow to insert the acetabular component of the prosthesis in its physiological place and achieve good results. 2. Shortening of femur and repositioning of components of prosthesis in 90 degrees knee flexion and also position on broken bed after operative procedure allowed to avoid neurological disorders. 3. Cementless and hydroxyapatite-covered femoral component of the prosthesis correctly stabilize place of femur osteotomy.

  16. Why advanced computing? The key to space-based operations

    NASA Astrophysics Data System (ADS)

    Phister, Paul W., Jr.; Plonisch, Igor; Mineo, Jack

    2000-11-01

    The 'what is the requirement?' aspect of advanced computing and how it relates to and supports Air Force space-based operations is a key issue. In support of the Air Force Space Command's five major mission areas (space control, force enhancement, force applications, space support and mission support), two-fifths of the requirements have associated stringent computing/size implications. The Air Force Research Laboratory's 'migration to space' concept will eventually shift Science and Technology (S&T) dollars from predominantly airborne systems to airborne-and-space related S&T areas. One challenging 'space' area is in the development of sophisticated on-board computing processes for the next generation smaller, cheaper satellite systems. These new space systems (called microsats or nanosats) could be as small as a softball, yet perform functions that are currently being done by large, vulnerable ground-based assets. The Joint Battlespace Infosphere (JBI) concept will be used to manage the overall process of space applications coupled with advancements in computing. The JBI can be defined as a globally interoperable information 'space' which aggregates, integrates, fuses, and intelligently disseminates all relevant battlespace knowledge to support effective decision-making at all echelons of a Joint Task Force (JTF). This paper explores a single theme -- on-board processing is the best avenue to take advantage of advancements in high-performance computing, high-density memories, communications, and re-programmable architecture technologies. The goal is to break away from 'no changes after launch' design to a more flexible design environment that can take advantage of changing space requirements and needs while the space vehicle is 'on orbit.'

  17. Wormhole Formation in RSRM Nozzle Joint Backfill

    NASA Technical Reports Server (NTRS)

    Stevens, J.

    2000-01-01

    The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and

  18. Management of acute unstable acromioclavicular joint injuries.

    PubMed

    Cisneros, Luis Natera; Reiriz, Juan Sarasquete

    2016-12-01

    Surgical management of acute unstable acromioclavicular joint injuries should be focused on realigning the torn ends of the ligaments to allow for healing potential. The most widely utilized treatment methods incorporate the use of metal hardware, which can alter the biomechanics of the acromioclavicular joint. This leads to a second surgical procedure for hardware removal once the ligaments have healed. Patients with unstable acromioclavicular joint injuries managed with arthroscopy-assisted procedures have shown good and excellent clinical outcomes, without the need for a second operation. These procedures incorporate a coracoclavicular suspension device aimed to function as an internal brace, narrowing the coracoclavicular space thus allowing for healing of the torn coracoclavicular ligaments. The lesser morbidity of a minimally invasive approach and the possibility to diagnose and treat concomitant intraarticular injuries; no obligatory implant removal, and the possibility of having a straight visualization of the inferior aspect of the base of the coracoid (convenient when placing coracoclavicular fixation systems) are the main advantages of the arthroscopic approach over classic open procedures. This article consists on a narrative review of the literature in regard to the management of acute acromioclavicular joint instability.

  19. Joint Chiefs of Staff > Directorates > J2 | Joint Staff Intelligence

    Science.gov Websites

    on Facebook on Flickr Joint Chiefs► Army Chief of Staff Marine Corps Commandant Chief of Naval Operations Air Force Chief of Staff Chief of National Guard Bureau Biographies Directorates Directorates of

  20. Robust control of multi-jointed arm with a decentralized autonomous control mechanism

    NASA Technical Reports Server (NTRS)

    Kimura, Shinichi; Miyazaki, Ken; Suzuki, Yoshiaki

    1994-01-01

    A decentralized autonomous control mechanism applied to the control of three dimensional manipulators and its robustness to partial damage was assessed by computer simulation. Decentralized control structures are believed to be quite robust to time delay between the operator and the target system. A 10-jointed manipulator based on our control mechanism was able to continue its positioning task in three-dimensional space without revision of the control program, even after some of its joints were damaged. These results suggest that this control mechanism can be effectively applied to space telerobots, which are associated with serious time delay between the operator and the target system, and which cannot be easily repaired after being partially damaged.

  1. Laundry joint venture.

    PubMed

    Giancola, D; Voyvodich, M

    1984-12-01

    Many hospitals are concerned about the loss of control which is associated with contracting for linen service. On the the hand, many laundries do not have the resources or experience to serve hospitals in a comprehensive and trouble-free manner. In many communities a joint venture, such as the one described here, can successfully combine the interests of the hospital and laundry communities without causing the hospitals to lose control of the service and without requiring the laundry operator to have detailed knowledge of hospital operations. As more hospitals opt for contract service, and if this service is to be provided at the lowest total cost, the hospitals and the laundries must come to grips with the problems surrounding the laundry-hospital interface. A joint venture, such as that described here, is one way to accomplish this.

  2. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    PubMed

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  3. Passivity/Lyapunov based controller design for trajectory tracking of flexible joint manipulators

    NASA Technical Reports Server (NTRS)

    Sicard, Pierre; Wen, John T.; Lanari, Leonardo

    1992-01-01

    A passivity and Lyapunov based approach for the control design for the trajectory tracking problem of flexible joint robots is presented. The basic structure of the proposed controller is the sum of a model-based feedforward and a model-independent feedback. Feedforward selection and solution is analyzed for a general model for flexible joints, and for more specific and practical model structures. Passivity theory is used to design a motor state-based controller in order to input-output stabilize the error system formed by the feedforward. Observability conditions for asymptotic stability are stated and verified. In order to accommodate for modeling uncertainties and to allow for the implementation of a simplified feedforward compensation, the stability of the system is analyzed in presence of approximations in the feedforward by using a Lyapunov based robustness analysis. It is shown that under certain conditions, e.g., the desired trajectory is varying slowly enough, stability is maintained for various approximations of a canonical feedforward.

  4. Homeland Defense Joint Center for Operational Analysis and Lessons Learned Quarterly Bulletin, Volume 7, Issue 1, December 2004

    DTIC Science & Technology

    2004-12-01

    domestic use of the armed forces. 9Joint Center for Operational Analysis and Lessons Learned (JCOA-LL) Bulletin An almost invisible law In many...enacted a program to increase significantly the role of the armed forces in drug interdiction as part of the Defense Authorization Act for 1989. The...technology, expanded intelligence collection, and the formation of new partnerships are necessary. • Arms control and other multilateral agreements will be

  5. Wi-Fi and satellite-based location techniques for intelligent agricultural machinery controlled by a human operator.

    PubMed

    Drenjanac, Domagoj; Tomic, Slobodanka; Agüera, Juan; Perez-Ruiz, Manuel

    2014-10-22

    In the new agricultural scenarios, the interaction between autonomous tractors and a human operator is important when they jointly perform a task. Obtaining and exchanging accurate localization information between autonomous tractors and the human operator, working as a team, is a critical to maintaining safety, synchronization, and efficiency during the execution of a mission. An advanced localization system for both entities involved in the joint work, i.e., the autonomous tractors and the human operator, provides a basis for meeting the task requirements. In this paper, different localization techniques for a human operator and an autonomous tractor in a field environment were tested. First, we compared the localization performances of two global navigation satellite systems' (GNSS) receivers carried by the human operator: (1) an internal GNSS receiver built into a handheld device; and (2) an external DGNSS receiver with centimeter-level accuracy. To investigate autonomous tractor localization, a real-time kinematic (RTK)-based localization system installed on autonomous tractor developed for agricultural applications was evaluated. Finally, a hybrid localization approach, which combines distance estimates obtained using a wireless scheme with the position of an autonomous tractor obtained using an RTK-GNSS system, is proposed. The hybrid solution is intended for user localization in unstructured environments in which the GNSS signal is obstructed. The hybrid localization approach has two components: (1) a localization algorithm based on the received signal strength indication (RSSI) from the wireless environment; and (2) the acquisition of the tractor RTK coordinates when the human operator is near the tractor. In five RSSI tests, the best result achieved was an average localization error of 4 m. In tests of real-time position correction between rows, RMS error of 2.4 cm demonstrated that the passes were straight, as was desired for the autonomous tractor. From

  6. Wi-Fi and Satellite-Based Location Techniques for Intelligent Agricultural Machinery Controlled by a Human Operator

    PubMed Central

    Drenjanac, Domagoj; Tomic, Slobodanka; Agüera, Juan; Perez-Ruiz, Manuel

    2014-01-01

    In the new agricultural scenarios, the interaction between autonomous tractors and a human operator is important when they jointly perform a task. Obtaining and exchanging accurate localization information between autonomous tractors and the human operator, working as a team, is a critical to maintaining safety, synchronization, and efficiency during the execution of a mission. An advanced localization system for both entities involved in the joint work, i.e., the autonomous tractors and the human operator, provides a basis for meeting the task requirements. In this paper, different localization techniques for a human operator and an autonomous tractor in a field environment were tested. First, we compared the localization performances of two global navigation satellite systems’ (GNSS) receivers carried by the human operator: (1) an internal GNSS receiver built into a handheld device; and (2) an external DGNSS receiver with centimeter-level accuracy. To investigate autonomous tractor localization, a real-time kinematic (RTK)-based localization system installed on autonomous tractor developed for agricultural applications was evaluated. Finally, a hybrid localization approach, which combines distance estimates obtained using a wireless scheme with the position of an autonomous tractor obtained using an RTK-GNSS system, is proposed. The hybrid solution is intended for user localization in unstructured environments in which the GNSS signal is obstructed. The hybrid localization approach has two components: (1) a localization algorithm based on the received signal strength indication (RSSI) from the wireless environment; and (2) the acquisition of the tractor RTK coordinates when the human operator is near the tractor. In five RSSI tests, the best result achieved was an average localization error of 4 m. In tests of real-time position correction between rows, RMS error of 2.4 cm demonstrated that the passes were straight, as was desired for the autonomous tractor

  7. Changes in temporomandibular joint spaces after arthroscopic disc repositioning: a self-control study

    PubMed Central

    Kai Hu, Ying; Abdelrehem, Ahmed; Yang, Chi; Cai, Xie Yi; Xie, Qian Yang; Sah, Manoj Kumar

    2017-01-01

    Disc repositioning is a common procedure for patients with anterior disc displacement (ADD). The purpose of this retrospective record-based study was to evaluate changes in the widths of joint spaces and condylar position changes in patients with unilateral ADD following arthroscopic disc repositioning, with the healthy sides as self-control, using magnetic resonance images (MRI).Widths of anterior, superior, and posterior joint spaces (AS, SS, and PS) were measured. The condylar position was described as anterior, centric or posterior, expressed as . Paired-t test and Chi-square test were used to analyze the data. Fifty-four records conformed to the inclusion criteria (mean age of 21.02 years). Widths of SS and PS increased significantly after surgery (P < 0.001) on the operative sides, while joint spaces of healthy sides and AS of operative sides had no significant changes. Dominant location of condyles of operative sides changed from a posterior position to an anterior position, while healthy sides were mostly centric condylar position no matter preoperatively or postoperatively. Therefore, the results of this study indicate that unilateral arthroscopic disc repositioning significantly increases the posterior and superior spaces of the affected joints, without affecting spaces of the healthy sides. PMID:28361905

  8. Joint kinematic calculation based on clinical direct kinematic versus inverse kinematic gait models.

    PubMed

    Kainz, H; Modenese, L; Lloyd, D G; Maine, S; Walsh, H P J; Carty, C P

    2016-06-14

    Most clinical gait laboratories use the conventional gait analysis model. This model uses a computational method called Direct Kinematics (DK) to calculate joint kinematics. In contrast, musculoskeletal modelling approaches use Inverse Kinematics (IK) to obtain joint angles. IK allows additional analysis (e.g. muscle-tendon length estimates), which may provide valuable information for clinical decision-making in people with movement disorders. The twofold aims of the current study were: (1) to compare joint kinematics obtained by a clinical DK model (Vicon Plug-in-Gait) with those produced by a widely used IK model (available with the OpenSim distribution), and (2) to evaluate the difference in joint kinematics that can be solely attributed to the different computational methods (DK versus IK), anatomical models and marker sets by using MRI based models. Eight children with cerebral palsy were recruited and presented for gait and MRI data collection sessions. Differences in joint kinematics up to 13° were found between the Plug-in-Gait and the gait 2392 OpenSim model. The majority of these differences (94.4%) were attributed to differences in the anatomical models, which included different anatomical segment frames and joint constraints. Different computational methods (DK versus IK) were responsible for only 2.7% of the differences. We recommend using the same anatomical model for kinematic and musculoskeletal analysis to ensure consistency between the obtained joint angles and musculoskeletal estimates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Concept of Operations for the Establishment of the Joint Pathology Center

    DTIC Science & Technology

    2008-12-19

    the Joint Task Force National Capital Region Medical (JTF CapMed ) in collaboration with the Uniformed Services University of Health Sciences (USUHS...Medical Examiner (OAFME). The Board deems the identification of appropriate support for the OAFME as critical , since with the disestablishment of...the DoD. The establishment of the JPC within JTF CapMed is a logical choice to the extent that JTF Cap Med is a joint medical organization and can

  10. Camera Based Closed Loop Control for Partial Penetration Welding of Overlap Joints

    NASA Astrophysics Data System (ADS)

    Abt, F.; Heider, A.; Weber, R.; Graf, T.; Blug, A.; Carl, D.; Höfler, H.; Nicolosi, L.; Tetzlaff, R.

    Welding of overlap joints with partial penetration in automotive applications is a challenging process, since the laser power must be set very precisely to achieve a proper connection between the two joining partners without damaging the backside of the sheet stack. Even minor changes in welding conditions can lead to bad results. To overcome this problem a camera based closed loop control for partial penetration welding of overlap joints was developed. With this closed loop control it is possible to weld such configurations with a stable process result even under changing welding conditions.

  11. Skull Base Erosion Resulting From Primary Tumors of the Temporomandibular Joint and Skull Base Region: Our Classification and Reconstruction Experience.

    PubMed

    Chen, Min-Jie; Yang, Chi; Zheng, Ji-Si; Bai, Guo; Han, Zi-Xiang; Wang, Yi-Wen

    2018-06-01

    We sought to introduce our classification and reconstruction protocol for skull base erosions in the temporomandibular joint and skull base region. Patients with neoplasms in the temporomandibular joint and skull base region treated from January 2006 to March 2017 were reviewed. Skull base erosion was classified into 3 types according to the size of the defect. We included 33 patients, of whom 5 (15.2%) had type I defects (including 3 in whom free fat grafts were placed and 2 in whom deep temporal fascial fat flaps were placed). There were 8 patients (24.2%) with type II defects, all of whom received deep temporal fascial fat flaps. A total of 20 patients (60.6%) had type III defects, including 17 in whom autogenous bone grafts were placed, 1 in whom titanium mesh was placed, and 2 who received total alloplastic joints. The mean follow-up period was 50 months. All of the patients exhibited stable occlusion and good facial symmetry. No recurrence was noted. Our classification and reconstruction principles allowed reliable morpho-functional skull base reconstruction. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Enhanced control of a flexure-jointed micromanipulation system using a vision-based servoing approach

    NASA Astrophysics Data System (ADS)

    Chuthai, T.; Cole, M. O. T.; Wongratanaphisan, T.; Puangmali, P.

    2018-01-01

    This paper describes a high-precision motion control implementation for a flexure-jointed micromanipulator. A desktop experimental motion platform has been created based on a 3RUU parallel kinematic mechanism, driven by rotary voice coil actuators. The three arms supporting the platform have rigid links with compact flexure joints as integrated parts and are made by single-process 3D printing. The mechanism overall size is approximately 250x250x100 mm. The workspace is relatively large for a flexure-jointed mechanism, being approximately 20x20x6 mm. A servo-control implementation based on pseudo-rigid-body models (PRBM) of kinematic behavior combined with nonlinear-PID control has been developed. This is shown to achieve fast response with good noise-rejection and platform stability. However, large errors in absolute positioning occur due to deficiencies in the PRBM kinematics, which cannot accurately capture flexure compliance behavior. To overcome this problem, visual servoing is employed, where a digital microscopy system is used to directly measure the platform position by image processing. By adopting nonlinear PID feedback of measured angles for the actuated joints as inner control loops, combined with auxiliary feedback of vision-based measurements, the absolute positioning error can be eliminated. With controller gain tuning, fast dynamic response and low residual vibration of the end platform can be achieved with absolute positioning accuracy within ±1 micron.

  13. [Generalised Form of Synovial Chondromatosis of the Knee Joint].

    PubMed

    Vališ, P; Vyskočil, R

    2016-01-01

    This study describes a diagnostic and therapeutic algorithm in a 53-year-old male patient who was diagnosed with a synovial chondromatosis of the knee joint extending to the popliteal fossa and soft tissues around the knee. Because of the presence of massive nodules, the patient was indicated for total synovectomy, with removal of pathologically changed cartilaginous tissue, performed by combined anterior and posterior approaches to the knee joint. Despite complete removal of the synovium and loose cartilage bodies and the patient's pain relief in the post-operative time, three years after the operation new problems appeared. Magnetic resonance imaging (MRI) confirmed a relapse of synovial chondromatosis and the patient was indicated for revision surgery of the knee joint. The results of physical examination and MRI scans, and intra-operative findings in the patient are reported. synovial chondromatosis, total synovectomy, direct anterior and posterior approaches to the knee joint.

  14. Results of arthroscopic joint debridement in different stages of chondromalacia of the knee joint.

    PubMed

    Krüger, T; Wohlrab, D; Birke, A; Hein, W

    2000-01-01

    A retrospective study was performed of 161 patients who had undergone arthroscopic operation for chondromalacia of the knee joint. After an average follow-up period of 40 (range 10-72) months, patients with severe articular cartilage lesions who had undergone articular lavage alone showed significantly poorer results (P < 0.001). With the same stage of chondromalacia and having undergone the same surgical procedure, younger patients showed better results than older patients. The more effective interruption of the circulus vitiosus during the development of degenerative joint diseases is the primary cause for better results achieved by mechanical debridement of the joint for patients suffering from grade 2 or higher. According to the literature, aggressive subchondral abrasion in severely degenerated knees does not show any benefits. Apparently, the success of the therapy depends to a great extent on the inferiority of the potential degenerative regenerate (lack of capacity of intrinsic regeneration of the hyaline cartilage) as well as on the grade and the progression of chondromalacia. Almost every second patient suffering from grade 4 chondromalacia complained of recurrent pain 1 year postoperatively. One of every 6 patients received a knee joint prosthesis within the 1st year. Therefore, the patients' preoperative expectations have to be clearly objectified. The surgical procedure as an operation with a low complication risk can also be justified as a temporary alternative to total knee arthroplasty in patients suffering from a high-grade degeneration of the joint.

  15. Joint with application in electrochemical devices

    DOEpatents

    Weil, K Scott [Richland, WA; Hardy, John S [Richland, WA

    2010-09-14

    A joint for use in electrochemical devices, such as solid oxide fuel cells (SOFCs), oxygen separators, and hydrogen separators, that will maintain a hermetic seal at operating temperatures of greater than 600.degree. C., despite repeated thermal cycling excess of 600.degree. C. in a hostile operating environment where one side of the joint is continuously exposed to an oxidizing atmosphere and the other side is continuously exposed to a wet reducing gas. The joint is formed of a metal part, a ceramic part, and a flexible gasket. The flexible gasket is metal, but is thinner and more flexible than the metal part. As the joint is heated and cooled, the flexible gasket is configured to flex in response to changes in the relative size of the metal part and the ceramic part brought about by differences in the coefficient of thermal expansion of the metal part and the ceramic part, such that substantially all of the tension created by the differences in the expansion and contraction of the ceramic and metal parts is absorbed and dissipated by flexing the flexible gasket.

  16. Nonlinear optical cryptosystem based on joint Fresnel transform correlator under vector wave illumination

    NASA Astrophysics Data System (ADS)

    Xueju, Shen; Chao, Lin; Xiao, Zou; Jianjun, Cai

    2015-05-01

    We present a nonlinear optical cryptosystem with multi-dimensional keys including phase, polarization and diffraction distance. To make full use of the degrees of freedom that optical processing offers, an elaborately designed vector wave with both a space-variant phase and locally linear polarization is generated with a common-path interferometer for illumination. The joint transform correlator in the Fresnel domain, implemented with a double optical wedge, is utilized as the encryption framework which provides an additional key known as the Fresnel diffraction distance. Two nonlinear operations imposed on the recorded joint Fresnel power distribution (JFPD) by a charge coupled device (CCD) are adopted. The first one is the division of power distribution of the reference window random function which is previously proposed by researchers and can improve the quality of the decrypted image. The second one is the recording of a hybrid JFPD using a micro-polarizers array with orthogonal and random transmissive axes attached to the CCD. Then the hybrid JFPD is further scrambled by substituting random noise for partial power distribution. The two nonlinear operations break the linearity of this cryptosystem and provide ultra security. We verify our proposal using a quick response code for noise-free recovery.

  17. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  18. Joint-operation in water resources project in Indonesia: Integrated or non-integrated

    NASA Astrophysics Data System (ADS)

    Ophiyandri, Taufika; Istijono, Bambang; Hidayat, Benny

    2017-11-01

    The construction of large water resources infrastructure project often involved a joint-operation (JO) project between two or more construction companies. The form of JO can be grouped into two categories - an integrated type and a non-integrated type. This paper investigates the reason of forming a JO project made by companies. The specific advantages and problems of JO project is also analysed in this paper. In order to achieve the objectives, three water resources infrastructure projects were selected as case studies. Data was gathered by conducting 11 semi-structured interviews to project owners, contractor managers, and project staffs. Data was analysed by means of content analysis. It was found that the most fundamental factor to form a JO is to win a competition or tender. An integrated model is in favour because it can reduce overhead costs and has a simple management system, while a non-integrated model is selected because it can avoid a sleeping partner and make contractor more responsible for their own job.

  19. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  20. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  1. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  2. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  3. 14 CFR 121.533 - Responsibility for operational control: Domestic operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...

  4. Joint Chiefs of Staff > Media > News

    Science.gov Websites

    Facebook on Flickr Joint Chiefs Army Chief of Staff Marine Corps Commandant Chief of Naval Operations Air Force Chief of Staff Chief of National Guard Bureau Biographies Directorates Directorates of Management Readout of Chairman of the Joint Chiefs of Staff Gen. Dunford's Meeting with Chief of the Turkish General

  5. Joint working. Local differences.

    PubMed

    Hudson, B

    1997-09-18

    The interface between social care and primary healthcare remains underdeveloped. Where joint working is effective, it is the result of co-operation, trust and mutual respect. Successful local networks take account of professional autonomy.

  6. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  7. Traffic in the operating room during joint replacement is a multidisciplinary problem

    PubMed Central

    Bédard, Martin; Pelletier-Roy, Rémi; Angers-Goulet, Mathieu; Leblanc, Pierre-Alexandre; Pelet, Stéphane

    2015-01-01

    Background Door openings disrupt the laminar air flow and increase the bacterial count in the operating room (OR). We aimed to define the incidence of door openings in the OR during primary total joint arthroplasty (TJA) surgeries and determine whether measures were needed and/or possible to reduce OR staff traffic. Methods We recorded the number of door openings during 100 primary elective TJA surgeries; the OR personnel were unaware of the observer’s intention. Operating time was divided into the preincision period, defined as the time from the opening of surgical trays to skin incision, and the postincision period, defined as time from incision to dressing application. Results The mean number of door openings during primary TJA was 71.1 (range 35–176) with a mean operative time of 111.9 (range 53–220) minutes, for an average of 0.64 (range 0.36–1.05) door openings/min. Nursing staff were responsible for 52.2% of total door openings, followed by anesthesia staff at 23.9% and orthopedic staff at 12.7%. In the preincision period, we observed an average of 0.84 door openings/min, with nursing and orthopedic personnel responsible for most of the door openings. The postincision period yielded an average of 0.54 door openings/min, with nursing and anesthesia personnel being responsible for most of the door openings. Conclusion There is a high incidence of door openings during TJA. Because we observed a range in the number of door openings per surgery, we believe it is possible to reduce this number during TJA. PMID:26022153

  8. Bio-inspired flexible joints with passive feathering for robotic fish pectoral fins.

    PubMed

    Behbahani, Sanaz Bazaz; Tan, Xiaobo

    2016-05-04

    In this paper a novel flexible joint is proposed for robotic fish pectoral fins, which enables a swimming behavior emulating the fin motions of many aquatic animals. In particular, the pectoral fin operates primarily in the rowing mode, while undergoing passive feathering during the recovery stroke to reduce hydrodynamic drag on the fin. The latter enables effective locomotion even with symmetric base actuation during power and recovery strokes. A dynamic model is developed to facilitate the understanding and design of the joint, where blade element theory is used to calculate the hydrodynamic forces on the pectoral fins, and the joint is modeled as a paired torsion spring and damper. Experimental results on a robotic fish prototype are presented to illustrate the effectiveness of the joint mechanism, validate the proposed model, and indicate the utility of the proposed model for the optimal design of joint depth and stiffness in achieving the trade-off between swimming speed and mechanical efficiency.

  9. Cost-Effective Mobile-Based Healthcare System for Managing Total Joint Arthroplasty Follow-Up.

    PubMed

    Bitsaki, Marina; Koutras, George; Heep, Hansjoerg; Koutras, Christos

    2017-01-01

    Long-term follow-up care after total joint arthroplasty is essential to evaluate hip and knee arthroplasty outcomes, to provide information to physicians and improve arthroplasty performance, and to improve patients' health condition. In this paper, we aim to improve the communication between arthroplasty patients and physicians and to reduce the cost of follow-up controls based on mobile application technologies and cloud computing. We propose a mobile-based healthcare system that provides cost-effective follow-up controls for primary arthroplasty patients through questions about symptoms in the replaced joint, questionnaires (WOMAC and SF-36v2) and the radiological examination of knee or hip joint. We also perform a cost analysis for a set of 423 patients that were treated in the University Clinic for Orthopedics in Essen-Werden. The estimation of healthcare costs shows significant cost savings (a reduction of 63.67% for readmission rate 5%) in both the University Clinic for Orthopedics in Essen-Werden and the state of North Rhine-Westphalia when the mobile-based healthcare system is applied. We propose a mHealth system to reduce the cost of follow-up assessments of arthroplasty patients through evaluation of diagnosis, self-monitoring, and regular review of their health status.

  10. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  11. A Cadaveric Study on Sacroiliac Joint Injection

    PubMed Central

    Zou, Yu-Cong; Li, Yi-Kai; Yu, Cheng-Fu; Yang, Xian-Wen; Chen, Run-Qi

    2015-01-01

    The scope of this study was to explore the possibility as well as the feasibility of sacroiliac joint injection following simple X-ray clip location. For the cadaveric study, 10 fixed sacroiliac joint (SIJ) sectional specimens, 4 dried cadaveric pelvises and 21 embalmed adult cadaveric pelvises were dissected, followed by an injection of contrast agent into the joint. The irrigation of the agent was observed through CT scanning. For the radiologic study, 188 CT scans of ankylosing spondylitis patients (143 male, 45 female) were collected from 2010 to 2012, in Nanfang Hospital. What was measured was (1) Distance between the posterior midline and sagittal synovium; (2) Length of the sagittal synovium; (3) Distance between the midpoint of the sagittal synovium and posterior superior iliac spine; and (4) Distance between the superficial skin vertical to the sagittal synovium point were measured. For the practice-based study: 20 patients (17 males and 3 females) with early ankylosing spondylitis, from Nanfang Hospital affiliated with Southern Medical University were recruited, and sacroiliac joint unguided injections were done on the basis of the cadaveric and radiologic study. Only the inferior 1/3rd portion parallel to the posterior midline could be injected into since the superior 2/3rd portion were filled with interosseous ligaments. Thirteen of the 20 patients received successful injections as identified by CT scan using the contrast agent. Sacroiliac joint injection following simple X-ray clip location is possible and feasible if the operation is performed by trained physicians familiar with the sacroiliac joint and its surrounding anatomic structures. PMID:25692437

  12. Enhanced secure 4-D modulation space optical multi-carrier system based on joint constellation and Stokes vector scrambling.

    PubMed

    Liu, Bo; Zhang, Lijia; Xin, Xiangjun

    2018-03-19

    This paper proposes and demonstrates an enhanced secure 4-D modulation optical generalized filter bank multi-carrier (GFBMC) system based on joint constellation and Stokes vector scrambling. The constellation and Stokes vectors are scrambled by using different scrambling parameters. A multi-scroll Chua's circuit map is adopted as the chaotic model. Large secure key space can be obtained due to the multi-scroll attractors and independent operability of subcarriers. A 40.32Gb/s encrypted optical GFBMC signal with 128 parallel subcarriers is successfully demonstrated in the experiment. The results show good resistance against the illegal receiver and indicate a potential way for the future optical multi-carrier system.

  13. Joint Base Contracting: A Comparative Analysis of Joint Base Contracting Activities between Services

    DTIC Science & Technology

    2011-12-01

    INTENTIONALLY LEFT BLANK 1 I. INTRODUCTION A. OVERVIEW The idea of consolidating functions is not new in the corporate world, nor is it new in...combining the experience and skill of multiple organizations to improve corporate knowledge. The automobile industry has several examples of joint...objective process, no more than half of the Commission’s professional staff members could have worked for the DoD during the same year that they were a

  14. Pre-operative interventions (non-surgical and non-pharmacological) for patients with hip or knee osteoarthritis awaiting joint replacement surgery--a systematic review and meta-analysis.

    PubMed

    Wallis, Jason A; Taylor, Nicholas F

    2011-12-01

    To determine if pre-operative interventions for hip and knee osteoarthritis provide benefit before and after joint replacement. Systematic review with meta-analysis of randomised controlled trials (RCTs) of pre-operative interventions for people with hip or knee osteoarthritis awaiting joint replacement surgery. Standardised mean differences (SMD) were calculated for pain, musculoskeletal impairment, activity limitation, quality of life, and health service utilisation (length of stay and discharge destination). The GRADE approach was used to determine the quality of the evidence. Twenty-three RCTs involving 1461 participants awaiting hip or knee replacement surgery were identified. Meta-analysis provided moderate quality evidence that pre-operative exercise interventions for knee osteoarthritis reduced pain prior to knee replacement surgery (SMD (95% CI)=0.43 [0.13, 0.73]). None of the other meta-analyses investigating pre-operative interventions for knee osteoarthritis demonstrated any effect. Meta-analyses provided low to moderate quality evidence that exercise interventions for hip osteoarthritis reduced pain (SMD (95% CI)=0.52 [0.04, 1.01]) and improved activity (SMD (95% CI)=0.47 [0.11, 0.83]) prior to hip replacement surgery. Meta-analyses provided low quality evidence that exercise with education programs improved activity after hip replacement with reduced time to reach functional milestones during hospital stay (e.g., SMD (95% CI)=0.50 [0.10, 0.90] for first day walking). Low to moderate evidence from mostly small RCTs demonstrated that pre-operative interventions, particularly exercise, reduce pain for patients with hip and knee osteoarthritis prior to joint replacement, and exercise with education programs may improve activity after hip replacement. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Developing an evidence-based nursing protocol on wound drain management for total joint arthroplasty.

    PubMed

    Tsang, Lap Fung

    2015-05-01

    Although various drains have long been used for many years in total joint replacement, there is a paucity of evidence for the benefit of drain applications. Evidence suggests inconsistent practice in the use of drainage systems, whether intermittently applying suction or free of suction in the application of drainage systems, as well as the optimal timing for wound drain removal. It aimed to perform a systematic review to develop an evidence-based nursing protocol to manage wound drainage following total joint arthroplasty. A comprehensive systematic review of available evidence up to 2013. Searches of the EMBASE, Cochrane library, CINAHL, Medline electronic databases and an internet search by Yahoo and Google engine returned 2840 records, of which 11 met the inclusion criteria for this review. A further two papers were obtained through scanning the reference lists of those articles included from the initial literature search. Different clamping times were retrieved from the literature. A protocol was adapted for clinical application according to the summary of the retrieved information. It is suggested that clamping is performed 1 h after the insertion of suction drains post-operatively in the operating theatre. Wound drains should be clamped for 1 h if blood loss is more than 600 ml in 6 h in first 24 h. Wound drains should be clamped for 1 h if blood loss is more than 800 ml in 8 h thereafter. It is suggested that the drainage reservoir bottle should be mark and findings recorded in line with the principle of drain clamping. This means that the amount of drainage is measured and recorded every 6 h in first 24 h and every 8 h thereafter. It is suggested that wound drains should be remove before 48 h after TJR. If blood loss is less than 50 ml in past 6 h or less than 70 ml in past 8 h, the drain should be remove and the wound site should be monitored closely. This paper has guided nurses to develop an evidence-based protocol to improve patient care on wound drain

  16. [Operative treatment of sacroiliac joint fracture and dislocation in Tile C pelvic fracture with Colorado 2 system].

    PubMed

    Liu, Shuping; Zhou, Qing; Liu, Yuehong; Chen, Xi; Zhou, Yu; Zhang, Desheng; Fang, Zhi; Xu, Wei

    2011-12-01

    To explore the effectiveness of Colorado 2 system in the stability reconstruction of sacroiliac joint fracture and dislocation in Tile C pelvic fracture. Between February 2009 and January 2011, 8 cases of Tile C pelvic fracture were treated with Colorado 2 system. There were 3 males and 5 females with an average age of 34.4 years (range, 22-52 years). Fractures were caused by traffic accident in 3 cases, by falling from height in 3 cases, and by crash of heavy object in 2 cases. According to Tile classification, 5 cases were classified as C1-2, 2 cases as C1-3, and 1 case as C2. The time between injury and operation was 5-10 days (mean, 7 days). After skeletal traction reduction, Colorado 2 system was used to fix sacroiliac joint, and reconstruction plate or external fixation was selectively adopted. The postoperative X-ray films showed that the reduction of vertical and rotatory dislocation was satisfactory, posterior pelvic ring achieved effective stability. All the incisions healed by first intention, and no blood vessel or nerve injury occurred. Eight patients were followed up 6-24 months (mean, 12 months). No loosening or breakage of internal fixation was observed and no re-dislocation of sacroiliac joint occurred. The bone healing time was 6-12 months (mean, 9 months). According to Majeed's functional criterion, the results were excellent in 5 cases, good in 2 cases, and fair in 1 case at last follow-up. Colorado 2 system could provide immediate stability of pelvic posterior ring and good maintenance of reduction effect, which is an effective method in the therapy of sacroiliac joint fracture and dislocation in Tile C pelvic fracture.

  17. Design and simulation of a cable-pulley-based transmission for artificial ankle joints

    NASA Astrophysics Data System (ADS)

    Liu, Huaxin; Ceccarelli, Marco; Huang, Qiang

    2016-06-01

    In this paper, a mechanical transmission based on cable pulley is proposed for human-like actuation in the artificial ankle joints of human-scale. The anatomy articular characteristics of the human ankle is discussed for proper biomimetic inspiration in designing an accurate, efficient, and robust motion control of artificial ankle joint devices. The design procedure is presented through the inclusion of conceptual considerations and design details for an interactive solution of the transmission system. A mechanical design is elaborated for the ankle joint angular with pitch motion. A multi-body dynamic simulation model is elaborated accordingly and evaluated numerically in the ADAMS environment. Results of the numerical simulations are discussed to evaluate the dynamic performance of the proposed design solution and to investigate the feasibility of the proposed design in future applications for humanoid robots.

  18. Medical support for Operation Cooperative Nugget '95: joint readiness training in the post-cold war era.

    PubMed

    Jerant, A F; Epperly, T D; Marionneaux, R D

    1997-11-01

    The purpose of this paper is to report the demographic characteristics, injury and illness profiles, and dispositions of patients seen at the 249th General Hospital during its month-long deployment in support of Operation Cooperative Nugget '95 at the Joint Readiness Training Center (JRTC), Fort Polk, Louisiana. A descriptive analysis of patient demographic, diagnostic, and disposition data was performed. A total of 769 patient contacts were made, with orthopedic injuries (31%), dermatologic disorders (17%), upper respiratory infections (6%), and heat injuries (5%) accounting for the majority of visits. Because of aggressive preventive medicine interventions, there were no cases of heat stroke despite daily heat indices of 110 to 120 degrees F. In addition to emphasizing the importance of anticipating environmental medical threats, the authors relate some lessons learned, which should be valuable to medical providers tasked for future multinational operations other than war at the JRTC and elsewhere.

  19. Corrosion behavior in high-temperature pressurized water of Zircaloy-4 joints brazed with Zr-Cu-based amorphous filler alloys

    NASA Astrophysics Data System (ADS)

    Lee, Jung Gu; Lee, Gyoung-Ja; Park, Jin-Ju; Lee, Min-Ku

    2017-05-01

    The compositional effects of ternary Zr-Cu-X (X: Al, Fe) amorphous filler alloys on galvanic corrosion susceptibility in high-temperature pressurized water were investigated for Zircaloy-4 brazed joints. Through an Al-induced microgalvanic reaction that deteriorated the overall nobility of the joint, application of the Zr-Cu-Al filler alloy caused galvanic coupling to develop readily between the Al-bearing joint and the Al-free base metal, finally leading to massive localized corrosion of the joint. Contrastingly, joints prepared with a Zr-Cu-Fe filler alloy showed excellent corrosion resistance comparable to that of the Zircaloy-4 base metal, since the Cu and Fe elements forming fine intermetallic particles with Zr did not influence the electrochemical stability of the resultant joints. The present results demonstrate that Fe is a more suitable alloying element than Al for brazing filler alloys subjected to high-temperature corrosive environments.

  20. Geomechanical Response of Jointed Caprock During CO2 Geological Sequestration

    NASA Astrophysics Data System (ADS)

    Newell, P.; Martinez, M. J.; Bishop, J. E.

    2014-12-01

    Geological sequestration of CO2 refers to the injection of supercritical CO2 into deep reservoirs trapped beneath a low-permeability caprock formation. Maintaining caprock integrity during the injection process is the most important factor for a successful injection. In this work we evaluate the potential for jointed caprock during injection scenarios using coupled three-dimensional multiphase flow and geomechanics modeling. Evaluation of jointed/fractured caprock systems is of particular concern to CO2 sequestration because creation or reactivation of joints (mechanical damage) can lead to enhanced pathways for leakage. In this work, we use an equivalent continuum approach to account for the joints within the caprock. Joint's aperture and non-linear stiffness of the caprock will be updated dynamically based on the effective normal stress. Effective permeability field will be updated based on the joints' aperture creating an anisotropic permeability field throughout the caprock. This feature would add another coupling between the solid and fluid in addition to basic Terzaghi's effective stress concept. In this study, we evaluate the impact of the joint's orientation and geometry of caprock and reservoir layers on geomechanical response of the CO2 geological systems. This work is supported as part of the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Award Number DE-SC0001114. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  1. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy.

    PubMed

    Nieuwenhuys, Angela; Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with 'no or minor gait deviations' (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with 'no or minor gait deviations' differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus study

  2. Product evaluation : Ruscoe 983 joint sealant

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...

  3. Locations of Joint Physical Activity in Parent-Child Pairs Based on Accelerometer and GPS Monitoring

    PubMed Central

    Dunton, Genevieve Fridlund; Liao, Yue; Almanza, Estela; Jerrett, Micheal; Spruijt-Metz, Donna; Pentz, Mary Ann

    2012-01-01

    Background Parental factors may play an important role in influencing children’s physical activity levels. Purpose This cross-sectional study sought to describe the locations of joint physical activity among parents and children. Methods Parent-child pairs (N = 291) wore an Actigraph GT2M accelerometer and GlobalSat BT-335 Global Positioning Systems (GPS) device over the same 7-day period. Children were ages 8–14 years. Joint behavior was defined by a linear separation distance of less than 50m between parent and child. Land use classifications were assigned to GPS data points. Results Joint physical activity was spread across residential locations (35%), and commercial venues (24%), and open spaces/parks (20%). Obese children and parents performed less joint physical activity in open spaces/parks than under/normal weight children and parents (p’s < .01). Conclusions Understanding where joint parent-child physical activity naturally occurs may inform location-based interventions to promote these behaviors. PMID:23011914

  4. Increasing Ti-6Al-4V brazed joint strength equal to the base metal by Ti and Zr amorphous filler alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganjeh, E., E-mail: navidganjehie@sina.kntu.ac.ir; Sarkhosh, H.; Bajgholi, M.E.

    Microstructural features developed along with mechanical properties in furnace brazing of Ti-6Al-4V alloy using STEMET 1228 (Ti-26.8Zr-13Ni-13.9Cu, wt.%) and STEMET 1406 (Zr-9.7Ti-12.4Ni-11.2Cu, wt.%) amorphous filler alloys. Brazing temperatures employed were 900-950 Degree-Sign C for the titanium-based filler and 900-990 Degree-Sign C for the zirconium-based filler alloys, respectively. The brazing time durations were 600, 1200 and 1800 s. The brazed joints were evaluated by ultrasonic test, and their microstructures and phase constitutions analyzed by metallography, scanning electron microscopy and X-ray diffraction analysis. Since microstructural evolution across the furnace brazed joints primarily depends on their alloying elements such as Cu, Ni andmore » Zr along the joint. Accordingly, existence of Zr{sub 2}Cu, Ti{sub 2}Cu and (Ti,Zr){sub 2}Ni intermetallic compounds was identified in the brazed joints. The chemical composition of segregation region in the center of brazed joints was identical to virgin filler alloy content which greatly deteriorated the shear strength of the joints. Adequate brazing time (1800 s) and/or temperature (950 Degree-Sign C for Ti-based and 990 Degree-Sign C for Zr-based) resulted in an acicular Widmanstaetten microstructure throughout the entire joint section due to eutectoid reaction. This microstructure increased the shear strength of the brazed joints up to the Ti-6Al-4V tensile strength level. Consequently, Ti-6Al-4V can be furnace brazed by Ti and Zr base foils produced excellent joint strengths. - Highlights: Black-Right-Pointing-Pointer Temperature or time was the main factors of controlling braze joint strength. Black-Right-Pointing-Pointer Developing a Widmanstaetten microstructure generates equal strength to base metal. Black-Right-Pointing-Pointer Brittle intermetallic compounds like (Ti,Zr){sub 2}Ni/Cu deteriorate shear strength. Black-Right-Pointing-Pointer Ti and Zr base filler alloys were the best choice for

  5. The Joint Logistics Enterprise Enables Operation United Assistance

    DTIC Science & Technology

    2016-02-24

    Sustainment July–August 2015 JLE U.S. service members board a C-130 Hercules aircraft Oct. 22, 2014, in Dakar, Senegal, to travel to Liberia to...including Liberia , as the “least developed in the world.” With numerous governance challenges, harsh weather, limited infrastructure over a... Liberia with the USARAF G–4, who was also the Joint Forces Com- mand ( JFC) J–4, and 7 personnel from his directorate. Because of the global reach of

  6. Operation Corporate: Parallels of the Joint Operational Access Concept

    DTIC Science & Technology

    2013-04-04

    To) 04-04-2013 Master of Military Studies Research Paper September 2012 - April 2013 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER Operation Corporate...amphibious operations. Discussion: Many books, periodicals, and papers have been written about the Falklands War. Most of these cover a broad...periodicals, and papers have been written about the Falklands War. Most of these cover a broad overview of the air, naval, and ground campaign, or are very

  7. Joint Polar Satellite System

    NASA Technical Reports Server (NTRS)

    Trenkle, Timothy; Driggers, Phillip

    2011-01-01

    The Joint Polar Satellite System (JPSS) is a joint NOAA/NASA mission comprised of a series of polar orbiting weather and climate monitoring satellites which will fly in a sun-synchronous orbit, with a 1330 equatorial crossing time. JPSS resulted from the decision to reconstitute the National Polar-orbiting Operational Environmental Satellite System (NPOESS) into two separate programs, one to be run by the Department of Defense (DOD) and the other by NOAA. This decision was reached in early 2010, after numerous development issues caused a series of unacceptable delays in launching the NPOESS system.

  8. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  9. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  10. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  11. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  12. 14 CFR 121.535 - Responsibility for operational control: Flag operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...

  13. A hybrid joint based controller for an upper extremity exoskeleton

    NASA Astrophysics Data System (ADS)

    Mohd Khairuddin, Ismail; Taha, Zahari; Majeed, Anwar P. P. Abdul; Hakeem Deboucha, Abdel; Azraai Mohd Razman, Mohd; Aziz Jaafar, Abdul; Mohamed, Zulkifli

    2016-02-01

    This paper presents the modelling and control of a two degree of freedom upper extremity exoskeleton. The Euler-Lagrange formulation was used in deriving the dynamic modelling of both the human upper limb as well as the exoskeleton that consists of the upper arm and the forearm. The human model is based on anthropometrical measurements of the upper limb. The proportional-derivative (PD) computed torque control (CTC) architecture is employed in this study to investigate its efficacy performing joint-space control objectives specifically in rehabilitating the elbow and shoulder joints along the sagittal plane. An active force control (AFC) algorithm is also incorporated into the PD-CTC to investigate the effectiveness of this hybrid system in compensating disturbances. It was found that the AFC- PD-CTC performs well against the disturbances introduced into the system whilst achieving acceptable trajectory tracking as compared to the conventional PD-CTC control architecture.

  14. Evaluation of longitudinal construction joints on traffic operations and safety.

    DOT National Transportation Integrated Search

    2009-01-01

    Motorists generally follow the guidance provided by pavement markings, which are normally marked in : coincidence with the longitudinal construction joints, when the markings are necessary. At some locations, : however, there may be a difference betw...

  15. Decentralized control of large flexible structures by joint decoupling

    NASA Technical Reports Server (NTRS)

    Su, Tzu-Jeng; Juang, Jer-Nan

    1992-01-01

    A decentralized control design method is presented for large complex flexible structures by using the idea of joint decoupling. The derivation is based on a coupled substructure state-space model, which is obtained from enforcing conditions of interface compatibility and equilibrium to the substructure state-space models. It is shown that by restricting the control law to be localized state feedback and by setting the joint actuator input commands to decouple joint 'degrees of freedom' (dof) from interior dof, the global structure control design problem can be decomposed into several substructure control design problems. The substructure control gains and substructure observers are designed based on modified substructure state-space models. The controllers produced by the proposed method can operate successfully at the individual substructure level as well as at the global structure level. Therefore, not only control design but also control implementation is decentralized. Stability and performance requirement of the closed-loop system can be achieved by using any existing state feedback control design method. A two-component mass-spring damper system and a three-truss structure are used as examples to demonstrate the proposed method.

  16. Microstructure and Mechanical Properties of Hybrid Welded Joints with Laser and CO2-Shielded Arc

    NASA Astrophysics Data System (ADS)

    Wahba, M.; Mizutani, M.; Katayama, S.

    2016-07-01

    With the objective of reducing the operating costs, argon-rich shielding gas was replaced by 100% CO2 gas in hybrid laser-arc welding of shipbuilding steel. The welding parameters were optimized to obtain buried-arc transfer in order to mitigate spatter formation. Sound butt joints could be successfully produced for plates of 14 and 17 mm thickness in one welding pass. Subsequently, the welded joints were subjected to different tests to evaluate the influence of CO2 shielding gas on the mechanical properties of the welded joints. All tensile-tested specimens failed in the base material, indicating the higher strength of the welded joints. The impact toughness of the welded joints, measured at -20 °C, reached approximately 76% of that of the base material, which was well above the limit set by the relevant standard. The microstructure of the fusion zone consisted of grain boundary ferrite and acicular ferrite uniformly over the plate thickness except for the joint root where the microstructure was chiefly ferrite with an aligned second phase. This resulted in higher hardness in the root region compared with the top and middle parts of the fusion zone.

  17. What a Joint. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in helping students become familiar with meat processing--livestock at the stockyards, meat packers (wholesalers), and butcher shops--to the cooked state and to become familiar with the different joints (cuts or parts) of beef, lamb, and pork. The guide…

  18. Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection.

    PubMed

    Gallo, Jiri; Juranova, Jarmila; Svoboda, Michal; Zapletalova, Jana

    2017-09-01

    The aim of this study was to evaluate the characteristics of synovial fluid (SF) white cell count (SWCC) and neutrophil/lymphocyte percentage in the diagnosis of prosthetic joint infection (PJI) for particular threshold values. This was a prospective study of 391 patients in whom SF specimens were collected before total joint replacement revisions. SF was aspirated before joint capsule incision. The PJI diagnosis was based only on non-SF data. Receiver operating characteristic plots were constructed for the SWCC and differential counts of leukocytes in aspirated fluid. Logistic binomic regression was used to distinguish infected and non-infected cases in the combined data. PJI was diagnosed in 78 patients, and aseptic revision in 313 patients. The areas (AUC) under the curve for the SWCC, the neutrophil and lymphocyte percentages were 0.974, 0.962, and 0.951, respectively. The optimal cut-off for PJI was 3,450 cells/μL, 74.6% neutrophils, and 14.6% lymphocytes. Positive likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 19.0, 10.4, and 9.5, respectively. Negative likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 0.06, 0.076, and 0.092, respectively. Based on AUC, the present study identified cut-off values for the SWCC and differential leukocyte count for the diagnosis of PJI. The likelihood ratio for positive/negative SWCCs can significantly change the pre-test probability of PJI.

  19. Behavior of stress generated in semiconductor chips with high-temperature joints: Influence of mechanical properties of joint materials

    NASA Astrophysics Data System (ADS)

    Ito, H.; Kuwahara, M.; Ohta, R.; Usui, M.

    2018-04-01

    High-temperature joint materials are indispensable to realizing next-generation power modules with high-output performance. However, crack initiation resulting from stress concentration in semiconductor chips joined with high-temperature joint materials remains a critical problem in high-temperature operation. Therefore, clarifying the quantitative influence of joint materials on the stress generated in chips is essential. This study investigates the stress behavior of chips joined by Ni-Sn solid-liquid interdiffusion (SLID), which results in a high-temperature joint material likely to generate cracks after joining or when under thermal cycling. The results are compared with those fabricated using three types of solders, Pb-10%Sn, Sn-0.7%Cu, and Sn-10%Sb (mass %), which are conventional joint materials with different melting points and mechanical properties. Using Ni-Sn SLID results in the generation of high compressive stress (500 MPa) without stress relaxation after the joining process in contrast to the case of solders in which the compressive stresses are low (<300 MPa) and decrease to still lower levels (<250 MPa). In addition, no stress relaxation occurs during thermal cycling when using Ni-Sn SLID, whereas stress relaxation is clearly observed during heating to 200 °C using solders. Different stress behaviors between Ni-Sn SLID and other joint materials are illustrated by their mechanical strength and resistance against plastic and creep deformation. These results suggest that stress relaxation in a chip is key in suppressing crack initiation in highly reliable modules during high-temperature operation.

  20. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  1. Association Between Years of Experience and Ankle Joint Disorder in Male Student Basketball Players Based on Ultrasonography.

    PubMed

    Fukushima, Yaeko

    2017-04-01

    The goal of the study was to survey ankle joint disorder in male senior high school and college student basketball players based on the results of an ultrasonographic medical check-up of the ankle joint. The subjects were 17 senior high school student and 19 college student basketball players. Ultrasonography, evaluation of ATFL injury, and examination of the talocrural joint region were performed. The subjects were grouped based on the presence or absence of old ATFL injury, and subjects with ATFL injury were classified by the injured region: fibular insertion site, parenchyma, and talar insertion site. The talocrural joint region was evaluated based on the areas of the lateral margin, central region, and medial margin, and sites with an irregular bone contour and osteophyte were counted individually. The questionnaire asked about the patients' history of ankle injuries. A questionnaire survey revealed that 70-79% of all subjects had experienced a sprain at least once and 21-29% had frequently sprained the left or right foot 10 or more times in the past. On ultrasonography, there was no significant difference in ligament injury or injured site between the senior high school and college students, but the number of osteochondral findings in the talocrural joint region was significantly higher in the college students. In addition, the number of injured sites significantly increased in those with 10 or more years of playing experience. These results suggest that disorder of the talocrural joint region progresses with an increase in years of experience in student basketball players who do not take specific preventive measures against this injury.

  2. Environmental Assessment for Watershed Enhancements at Joint Base Elmendorf-Richardson

    DTIC Science & Technology

    2013-07-03

    Potassium permanganate would be utilized to prevent lethal dose of rotenone migrating beyond the largest beaver dam on Otter Creek. Lowering the lake level...Finding of No Significant Impact JBER Joint Base Elmendorf-Richardson KMnO4 potassium permanganate MOA Municipality of Anchorage NEPA National...Potassium permanganate would be utilized to prevent lethal dose of rotenone migrating beyond the largest beaver dam on Otter Creek. Lowering the lake

  3. Comparison of MRI-based estimates of articular cartilage contact area in the tibiofemoral joint.

    PubMed

    Henderson, Christopher E; Higginson, Jill S; Barrance, Peter J

    2011-01-01

    Knee osteoarthritis (OA) detrimentally impacts the lives of millions of older Americans through pain and decreased functional ability. Unfortunately, the pathomechanics and associated deviations from joint homeostasis that OA patients experience are not well understood. Alterations in mechanical stress in the knee joint may play an essential role in OA; however, existing literature in this area is limited. The purpose of this study was to evaluate the ability of an existing magnetic resonance imaging (MRI)-based modeling method to estimate articular cartilage contact area in vivo. Imaging data of both knees were collected on a single subject with no history of knee pathology at three knee flexion angles. Intra-observer reliability and sensitivity studies were also performed to determine the role of operator-influenced elements of the data processing on the results. The method's articular cartilage contact area estimates were compared with existing contact area estimates in the literature. The method demonstrated an intra-observer reliability of 0.95 when assessed using Pearson's correlation coefficient and was found to be most sensitive to changes in the cartilage tracings on the peripheries of the compartment. The articular cartilage contact area estimates at full extension were similar to those reported in the literature. The relationships between tibiofemoral articular cartilage contact area and knee flexion were also qualitatively and quantitatively similar to those previously reported. The MRI-based knee modeling method was found to have high intra-observer reliability, sensitivity to peripheral articular cartilage tracings, and agreeability with previous investigations when using data from a single healthy adult. Future studies will implement this modeling method to investigate the role that mechanical stress may play in progression of knee OA through estimation of articular cartilage contact area.

  4. An intelligent system with EMG-based joint angle estimation for telemanipulation.

    PubMed

    Suryanarayanan, S; Reddy, N P; Gupta, V

    1996-01-01

    Bio-control of telemanipulators is being researched as an alternate control strategy. This study investigates the use of surface EMG from the biceps to predict joint angle during flexion of the arm that can be used to control an anthropomorphic telemanipulator. An intelligent system based on neural networks and fuzzy logic has been developed to use the processed surface EMG signal and predict the joint angle. The system has been tested on various angles of flexion-extension of the arm and at several speeds of flexion-extension. Preliminary results show the RMS error between the predicted angle and the actual angle to be less than 3% during training and less than 15% during testing. The technique of direct bio-control using EMG has the potential as an interface for telemanipulation applications.

  5. 49 CFR 192.233 - Miter joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30... operated at a pressure that produces a hoop stress of less than 30 percent, but more than 10 percent, of... steel pipe to be operated at a pressure that produces a hoop stress of 10 percent or less of SMYS may...

  6. 49 CFR 192.233 - Miter joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30... operated at a pressure that produces a hoop stress of less than 30 percent, but more than 10 percent, of... steel pipe to be operated at a pressure that produces a hoop stress of 10 percent or less of SMYS may...

  7. 49 CFR 192.233 - Miter joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30... operated at a pressure that produces a hoop stress of less than 30 percent, but more than 10 percent, of... steel pipe to be operated at a pressure that produces a hoop stress of 10 percent or less of SMYS may...

  8. sEMG-based joint force control for an upper-limb power-assist exoskeleton robot.

    PubMed

    Li, Zhijun; Wang, Baocheng; Sun, Fuchun; Yang, Chenguang; Xie, Qing; Zhang, Weidong

    2014-05-01

    This paper investigates two surface electromyogram (sEMG)-based control strategies developed for a power-assist exoskeleton arm. Different from most of the existing position control approaches, this paper develops force control methods to make the exoskeleton robot behave like humans in order to provide better assistance. The exoskeleton robot is directly attached to a user's body and activated by the sEMG signals of the user's muscles, which reflect the user's motion intention. In the first proposed control method, the forces of agonist and antagonist muscles pair are estimated, and their difference is used to produce the torque of the corresponding joints. In the second method, linear discriminant analysis-based classifiers are introduced as the indicator of the motion type of the joints. Then, the classifier's outputs together with the estimated force of corresponding active muscle determine the torque control signals. Different from the conventional approaches, one classifier is assigned to each joint, which decreases the training time and largely simplifies the recognition process. Finally, the extensive experiments are conducted to illustrate the effectiveness of the proposed approaches.

  9. Quiet Short-Haul Research Aircraft Joint Navy/NASA Sea Trials

    NASA Technical Reports Server (NTRS)

    Queen, S.; Cochrane, J.

    1982-01-01

    The Quiet Short-Haul Research Aircraft (QSRA) is a flight facility which Ames Research Center is using to conduct a broad program of terminal area and low-speed, propulsive-life flight research. A joint Navy/NASA flight research program used the QSRA to investigate the application of advanced propulsive-lift technology to the naval aircraft-carrier environment. Flight performance of the QSRA is presented together with the results or the joint Navy/NASA flight program. During the joint program, the QSRA operated aboard the USS Kitty Hawk for 4 days, during which numerous unarrested landings and free deck takeoffs were accomplished. These operations demonstrated that a large aircraft incorporating upper-surface-blowing, propulsive-life technology can be operated in the aircraft-carrier environment without any unusual problems.

  10. Activities of the US-Japan Safety Monitor Joint Working Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard L. Savercool; Lee C. Cadwallader

    2004-09-01

    This paper documents the activities of the US-Japan exchange in the area of personnel safety at magnetic and laser fusion experiments. A near-miss event with a visiting scientist to the US in 1992 was the impetus for forming the Joint Working Group on Fusion Safety. This exchnge has been under way for over ten years and has provided many safety insights for both US and Japanese facility personnel at national institutes and at universities. The background and activities of the Joint Working Group are described, including the facilities that have been visited for safety walkthroughs, the participants from both countries,more » and the main safety issues examined during visits. Based on these visits, some operational safety ideas to enhance experiment safety are given. The near-term future plans of the Safety Monitor Joint Working group are also discussed.« less

  11. Joint Chiefs of Staff > About > Origin of Joint Concepts

    Science.gov Websites

    Commander in Chief of the Army and Navy; General George C. Marshall, Chief of Staff of the Army; Admiral Ernest J. King, Chief of Naval Operations and Commander in Chief of the U.S. Fleet; and General Henry H JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman

  12. Barratt signs mission decal in the JEM during Joint Operations

    NASA Image and Video Library

    2009-07-25

    S127-E-008623 (25 July 2009) --- Flight day 11 activities for the joint shuttle-station crews included the traditional autographing of the station. Astronaut Mike Barratt, Expedition 20 flight engineer, has the pen in this frame. Photo credit: NASA

  13. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy

    PubMed Central

    Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with ‘no or minor gait deviations’ (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with ‘no or minor gait deviations’ differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus

  14. An Approach and Framework to Synchronize Joint Exercises and Training with Military Operations

    DTIC Science & Technology

    2014-06-06

    13. SUPPLEMENTARY NOTES 14. ABSTRACT In this dynamic, complex, and uncertain global environment, supporting and conducting joint military...achieved by leveraging a globally networked approach and an integrated framework that shares resources and coordinates activities. A recommended...Intentionally left blank ABSTRACT In this dynamic, complex, and uncertain global environment, supporting and conducting joint military

  15. Experimental Investigation on Friction Stir Welding of Cryorolled AA2219 Aluminum Alloy Joints

    NASA Astrophysics Data System (ADS)

    Babu, K. Kamal; Panneerselvam, K.; Sathiya, P.; Haq, A. Noorul; Sundarrajan, S.; Mastanaiah, P.; Murthy, C. V. Srinivasa

    2017-07-01

    In this paper, experimental investigation on cryorolled aluminum AA2219-T87 plate by using friction stir welding (FSW) process is carried out. AA2219-T87 plates with a size of 200×100×22.4 mm were rolled and reduced to 12.2mm thickness (more than 45% of reduction in total thickness of the base material) at cryogenic temperature (operating temperature range -90--30∘C). The cryorolled (CR) plates have reduced grain size, improved hardness and increased corrosion resistance property compared with the uncryorolled AA2219-T87 plates. FSW joints of cryorolled AA2219-T87 plates were prepared using cylindrical threaded FSW tool pin profile. Mechanical and metallurgical behaviors of friction stir welded joints were analyzed and the effects of the FSW process parameters are discussed in this paper. The variation of microhardness in the FSW joint regions were correlated with the microstructure of FSW joints. Cryorolled plate and FSW joints were tested for corrosion resistance using potentiodynamic polarization test. FSW joints shows better result during the corrosion resistance analysis compared to base AA2219-T87. The X-ray diffraction (XRD) test results showed that fine α-Al grains with eutectic phase (Al2Cu) were present in the weld nugget (WN). The large clusters of strengthening precipitates were reduced in size and merged with the weld nugget portion.

  16. Effects-Based Operations in the Cyber Domain

    DTIC Science & Technology

    2017-05-03

    as the joint targeting methodology . The description that Batschelet gave the traditional targeting methodology included a process of, “Decide, Detect...technology, requires new planning and methodology to fight back. This paper evaluates current Department of Defense doctrine to look at ways to conduct...developing its cyber tactics, techniques, and procedures, which, includes various targeting methodologies , such as the use of effects-based

  17. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    NASA Astrophysics Data System (ADS)

    Frear, D. R.; Burchett, S. N.; Rashid, M. M.

    The thermomechanical fatigue failure of solder joints is increasingly becoming an important reliability issue. We present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. The single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.

  18. HMA Longitudinal Joint Evaluation and Construction

    DOT National Transportation Integrated Search

    2011-02-01

    Longitudinal joint quality is essential to the successful performance of asphalt pavements. A number of states have begun to implement longitudinal joint specifications, and most are based on determinations of density. However, distress at the joint ...

  19. Dynamic Analyses Including Joints Of Truss Structures

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith

    1991-01-01

    Method for mathematically modeling joints to assess influences of joints on dynamic response of truss structures developed in study. Only structures with low-frequency oscillations considered; only Coulomb friction and viscous damping included in analysis. Focus of effort to obtain finite-element mathematical models of joints exhibiting load-vs.-deflection behavior similar to measured load-vs.-deflection behavior of real joints. Experiments performed to determine stiffness and damping nonlinearities typical of joint hardware. Algorithm for computing coefficients of analytical joint models based on test data developed to enable study of linear and nonlinear effects of joints on global structural response. Besides intended application to large space structures, applications in nonaerospace community include ground-based antennas and earthquake-resistant steel-framed buildings.

  20. A transition-based joint model for disease named entity recognition and normalization.

    PubMed

    Lou, Yinxia; Zhang, Yue; Qian, Tao; Li, Fei; Xiong, Shufeng; Ji, Donghong

    2017-08-01

    Disease named entities play a central role in many areas of biomedical research, and automatic recognition and normalization of such entities have received increasing attention in biomedical research communities. Existing methods typically used pipeline models with two independent phases: (i) a disease named entity recognition (DER) system is used to find the boundaries of mentions in text and (ii) a disease named entity normalization (DEN) system is used to connect the mentions recognized to concepts in a controlled vocabulary. The main problems of such models are: (i) there is error propagation from DER to DEN and (ii) DEN is useful for DER, but pipeline models cannot utilize this. We propose a transition-based model to jointly perform disease named entity recognition and normalization, casting the output construction process into an incremental state transition process, learning sequences of transition actions globally, which correspond to joint structural outputs. Beam search and online structured learning are used, with learning being designed to guide search. Compared with the only existing method for joint DEN and DER, our method allows non-local features to be used, which significantly improves the accuracies. We evaluate our model on two corpora: the BioCreative V Chemical Disease Relation (CDR) corpus and the NCBI disease corpus. Experiments show that our joint framework achieves significantly higher performances compared to competitive pipeline baselines. Our method compares favourably to other state-of-the-art approaches. Data and code are available at https://github.com/louyinxia/jointRN. dhji@whu.edu.cn. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  1. Association Between Years of Experience and Ankle Joint Disorder in Male Student Basketball Players Based on Ultrasonography

    PubMed Central

    Fukushima, Yaeko

    2017-01-01

    Purpose The goal of the study was to survey ankle joint disorder in male senior high school and college student basketball players based on the results of an ultrasonographic medical check-up of the ankle joint. Materials and Methods The subjects were 17 senior high school student and 19 college student basketball players. Ultrasonography, evaluation of ATFL injury, and examination of the talocrural joint region were performed. The subjects were grouped based on the presence or absence of old ATFL injury, and subjects with ATFL injury were classified by the injured region: fibular insertion site, parenchyma, and talar insertion site. The talocrural joint region was evaluated based on the areas of the lateral margin, central region, and medial margin, and sites with an irregular bone contour and osteophyte were counted individually. The questionnaire asked about the patients’ history of ankle injuries. Results A questionnaire survey revealed that 70–79% of all subjects had experienced a sprain at least once and 21–29% had frequently sprained the left or right foot 10 or more times in the past. On ultrasonography, there was no significant difference in ligament injury or injured site between the senior high school and college students, but the number of osteochondral findings in the talocrural joint region was significantly higher in the college students. In addition, the number of injured sites significantly increased in those with 10 or more years of playing experience. Conclusion These results suggest that disorder of the talocrural joint region progresses with an increase in years of experience in student basketball players who do not take specific preventive measures against this injury. PMID:28603784

  2. Internet Based Remote Operations

    NASA Technical Reports Server (NTRS)

    Chamberlain, James

    1999-01-01

    This is the Final Report for the Internet Based Remote Operations Contract, has performed payload operations research support tasks March 1999 through September 1999. These tasks support the GSD goal of developing a secure, inexpensive data, voice, and video mission communications capability between remote payload investigators and the NASA payload operations team in the International Space Station (ISS) era. AZTek has provided feedback from the NASA payload community by utilizing its extensive payload development and operations experience to test and evaluate remote payload operations systems. AZTek has focused on use of the "public Internet" and inexpensive, Commercial-off-the-shelf (COTS) Internet-based tools that would most benefit "small" (e.g., $2 Million or less) payloads and small developers without permanent remote operations facilities. Such projects have limited budgets to support installation and development of high-speed dedicated communications links and high-end, custom ground support equipment and software. The primary conclusions of the study are as follows: (1) The trend of using Internet technology for "live" collaborative applications such as telescience will continue. The GSD-developed data and voice capabilities continued to work well over the "public" Internet during this period. 2. Transmitting multiple voice streams from a voice-conferencing server to a client PC to be mixed and played on the PC is feasible. 3. There are two classes of voice vendors in the market: - Large traditional phone equipment vendors pursuing integration of PSTN with Internet, and Small Internet startups.The key to selecting a vendor will be to find a company sufficiently large and established to provide a base voice-conferencing software product line for the next several years.

  3. Joint design of QC-LDPC codes for coded cooperation system with joint iterative decoding

    NASA Astrophysics Data System (ADS)

    Zhang, Shunwai; Yang, Fengfan; Tang, Lei; Ejaz, Saqib; Luo, Lin; Maharaj, B. T.

    2016-03-01

    In this paper, we investigate joint design of quasi-cyclic low-density-parity-check (QC-LDPC) codes for coded cooperation system with joint iterative decoding in the destination. First, QC-LDPC codes based on the base matrix and exponent matrix are introduced, and then we describe two types of girth-4 cycles in QC-LDPC codes employed by the source and relay. In the equivalent parity-check matrix corresponding to the jointly designed QC-LDPC codes employed by the source and relay, all girth-4 cycles including both type I and type II are cancelled. Theoretical analysis and numerical simulations show that the jointly designed QC-LDPC coded cooperation well combines cooperation gain and channel coding gain, and outperforms the coded non-cooperation under the same conditions. Furthermore, the bit error rate performance of the coded cooperation employing jointly designed QC-LDPC codes is better than those of random LDPC codes and separately designed QC-LDPC codes over AWGN channels.

  4. Saving Lives on the Battlefield (Part II) ? One Year Later A Joint Theater Trauma System and Joint Trauma System Review of Prehospital Trauma Care in Combined Joint Operations Area?Afghanistan (CJOA-A) Final Report, 30 May 2014.

    PubMed

    Sauer, Samual W; Robinson, John B; Smith, Michael P; Gross, Kirby R; Kotwal, Russ S; Mabry, Robert L; Butler, Frank K; Stockinger, Zsolt T; Bailey, Jeffrey A; Mavity, Mark E; Gillies, Duncan A

    2015-01-01

    The United States has achieved unprecedented survival rates, as high as 98%, for casualties arriving alive at the combat hospital. Our military medical personnel are rightly proud of this achievement. Commanders and Servicemembers are confident that if wounded and moved to a Role II or III medical facility, their care will be the best in the world. Combat casualty care, however, begins at the point of injury and continues through evacuation to those facilities. With up to 25% of deaths on the battlefield being potentially preventable, the prehospital environment is the next frontier for making significant further improvements in battlefield trauma care. Strict adherence to the evidence-based Tactical Combat Casualty Care (TCCC) Guidelines has been proven to reduce morbidity and mortality on the battlefield. However, full implementation across the entire force and commitment from both line and medical leadership continue to face ongoing challenges. This report on prehospital trauma in the Combined Joint Operations Area?Afghanistan (CJOA-A) is a follow-on to the one previously conducted in November 2012 and published in January 2013. Both assessments were conducted by the US Central Command (USCENTCOM) Joint Theater Trauma System (JTTS). Observations for this report were collected from December 2013 to January 2014 and were obtained directly from deployed prehospital providers, medical leaders, and combatant leaders. Significant progress has been made between these two reports with the establishment of a Prehospital Care Division within the JTTS, development of a prehospital trauma registry and weekly prehospital trauma conferences, and CJOA-A theater guidance and enforcement of prehospital documentation. Specific prehospital trauma-care achievements include expansion of transfusion capabilities forward to the point of injury, junctional tourniquets, and universal approval of tranexamic acid. 2015.

  5. Application of a passivity based control methodology for flexible joint robots to a simplified Space Shuttle RMS

    NASA Technical Reports Server (NTRS)

    Sicard, Pierre; Wen, John T.

    1992-01-01

    A passivity approach for the control design of flexible joint robots is applied to the rate control of a three-link arm modeled after the shoulder yaw joint of the Space Shuttle Remote Manipulator System (RMS). The system model includes friction and elastic joint couplings modeled as nonlinear springs. The basic structure of the proposed controller is the sum of a model-based feedforward and a model-independent feedback. A regulator approach with link state feedback is employed to define the desired motor state. Passivity theory is used to design a motor state-based controller to stabilize the error system formed by the feedforward. Simulation results show that greatly improved performance was obtained by using the proposed controller over the existing RMS controller.

  6. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    PubMed

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  7. Operational Risk Defined Through a Complex Operating Environment

    DTIC Science & Technology

    2015-02-26

    including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed , and completing and reviewing...This argument defines operational risk as any environmental, institutional, or social impediment to the principles of joint operations that disrupt...Restraint, Perseverance, and Legitimacy. This argument defines operational risk as any environmental, institutional, or social impediment to the

  8. U.S. Joint Special Operations Forces: Two Few, Overworked, Young, Homogenous & Macho to Fulfill the Unconventional Demands of the Long War?

    DTIC Science & Technology

    2008-05-28

    OVERWORKED , YOUNG, HOMOGENOUS, & MACHO TO FULFILL THE UNCONVENTIONAL DEMANDS OF THE LONG WAR? SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR...U.S. Joint Special Operations Forces: Two Few, Overworked , Young, Homogenous & Macho to Fulfill the Unconventional Demands of the Long War? 5a...to be the targets of nearly daily mortar, improvised explosive devices (IEDs), and occasional suicide vehicle-borne IED (SVBIED) attacks. It

  9. Spectral unmixing of agents on surfaces for the Joint Contaminated Surface Detector (JCSD)

    NASA Astrophysics Data System (ADS)

    Slamani, Mohamed-Adel; Chyba, Thomas H.; LaValley, Howard; Emge, Darren

    2007-09-01

    ITT Corporation, Advanced Engineering and Sciences Division, is currently developing the Joint Contaminated Surface Detector (JCSD) technology under an Advanced Concept Technology Demonstration (ACTD) managed jointly by the U.S. Army Research, Development, and Engineering Command (RDECOM) and the Joint Project Manager for Nuclear, Biological, and Chemical Contamination Avoidance for incorporation on the Army's future reconnaissance vehicles. This paper describes the design of the chemical agent identification (ID) algorithm associated with JCSD. The algorithm detects target chemicals mixed with surface and interferent signatures. Simulated data sets were generated from real instrument measurements to support a matrix of parameters based on a Design Of Experiments approach (DOE). Decisions based on receiver operating characteristics (ROC) curves and area-under-the-curve (AUC) measures were used to down-select between several ID algorithms. Results from top performing algorithms were then combined via a fusion approach to converge towards optimum rates of detections and false alarms. This paper describes the process associated with the algorithm design and provides an illustrating example.

  10. 3D GIS spatial operation based on extended Euler operators

    NASA Astrophysics Data System (ADS)

    Xu, Hongbo; Lu, Guonian; Sheng, Yehua; Zhou, Liangchen; Guo, Fei; Shang, Zuoyan; Wang, Jing

    2008-10-01

    The implementation of 3 dimensions spatial operations, based on certain data structure, has a lack of universality and is not able to treat with non-manifold cases, at present. ISO/DIS 19107 standard just presents the definition of Boolean operators and set operators for topological relationship query, and OGC GeoXACML gives formal definitions for several set functions without implementation detail. Aiming at these problems, based mathematical foundation on cell complex theory, supported by non-manifold data structure and using relevant research in the field of non-manifold geometry modeling for reference, firstly, this paper according to non-manifold Euler-Poincaré formula constructs 6 extended Euler operators and inverse operators to carry out creating, updating and deleting 3D spatial elements, as well as several pairs of supplementary Euler operators to convenient for implementing advanced functions. Secondly, we change topological element operation sequence of Boolean operation and set operation as well as set functions defined in GeoXACML into combination of extended Euler operators, which separates the upper functions and lower data structure. Lastly, we develop underground 3D GIS prototype system, in which practicability and credibility of extended Euler operators faced to 3D GIS presented by this paper are validated.

  11. Plausibility and parameter sensitivity of micro-finite element-based joint load prediction at the proximal femur.

    PubMed

    Synek, Alexander; Pahr, Dieter H

    2018-06-01

    A micro-finite element-based method to estimate the bone loading history based on bone architecture was recently presented in the literature. However, a thorough investigation of the parameter sensitivity and plausibility of this method to predict joint loads is still missing. The goals of this study were (1) to analyse the parameter sensitivity of the joint load predictions at one proximal femur and (2) to assess the plausibility of the results by comparing load predictions of ten proximal femora to in vivo hip joint forces measured with instrumented prostheses (available from www.orthoload.com ). Joint loads were predicted by optimally scaling the magnitude of four unit loads (inclined [Formula: see text] to [Formula: see text] with respect to the vertical axis) applied to micro-finite element models created from high-resolution computed tomography scans ([Formula: see text]m voxel size). Parameter sensitivity analysis was performed by varying a total of nine parameters and showed that predictions of the peak load directions (range 10[Formula: see text]-[Formula: see text]) are more robust than the predicted peak load magnitudes (range 2344.8-4689.5 N). Comparing the results of all ten femora with the in vivo loading data of ten subjects showed that peak loads are plausible both in terms of the load direction (in vivo: [Formula: see text], predicted: [Formula: see text]) and magnitude (in vivo: [Formula: see text], predicted: [Formula: see text]). Overall, this study suggests that micro-finite element-based joint load predictions are both plausible and robust in terms of the predicted peak load direction, but predicted load magnitudes should be interpreted with caution.

  12. Flight Deck Surface Trajectory-Based Operations

    NASA Technical Reports Server (NTRS)

    Foyle, David C.; Hooey, Becky L.; Bakowski, Deborah L.

    2017-01-01

    Surface Trajectory-Based Operations (STBO) is a future concept for surface operations where time requirements are incorporated into taxi operations to support surface planning and coordination. Pilot-in-the-loop flight deck simulations have been conducted to study flight deck displays algorithms to aid pilots in complying with the time requirements of time-based taxi operations (i.e., at discrete locations in 3 12 D operations or at all points along the route in 4DT operations). The results of these studies (conformance, time-of-arrival error, eye-tracking data, and safety ratings) are presented. Flight deck simulation work done in collaboration with DLR is described. Flight deck research issues in future auto-taxi operations are also introduced.

  13. Sacroiliac joint dysfunction.

    PubMed

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  14. Quantification of knee vibroarthrographic signal irregularity associated with patellofemoral joint cartilage pathology based on entropy and envelope amplitude measures.

    PubMed

    Wu, Yunfeng; Chen, Pinnan; Luo, Xin; Huang, Hui; Liao, Lifang; Yao, Yuchen; Wu, Meihong; Rangayyan, Rangaraj M

    2016-07-01

    Injury of knee joint cartilage may result in pathological vibrations between the articular surfaces during extension and flexion motions. The aim of this paper is to analyze and quantify vibroarthrographic (VAG) signal irregularity associated with articular cartilage degeneration and injury in the patellofemoral joint. The symbolic entropy (SyEn), approximate entropy (ApEn), fuzzy entropy (FuzzyEn), and the mean, standard deviation, and root-mean-squared (RMS) values of the envelope amplitude, were utilized to quantify the signal fluctuations associated with articular cartilage pathology of the patellofemoral joint. The quadratic discriminant analysis (QDA), generalized logistic regression analysis (GLRA), and support vector machine (SVM) methods were used to perform signal pattern classifications. The experimental results showed that the patients with cartilage pathology (CP) possess larger SyEn and ApEn, but smaller FuzzyEn, over the statistical significance level of the Wilcoxon rank-sum test (p<0.01), than the healthy subjects (HS). The mean, standard deviation, and RMS values computed from the amplitude difference between the upper and lower signal envelopes are also consistently and significantly larger (p<0.01) for the group of CP patients than for the HS group. The SVM based on the entropy and envelope amplitude features can provide superior classification performance as compared with QDA and GLRA, with an overall accuracy of 0.8356, sensitivity of 0.9444, specificity of 0.8, Matthews correlation coefficient of 0.6599, and an area of 0.9212 under the receiver operating characteristic curve. The SyEn, ApEn, and FuzzyEn features can provide useful information about pathological VAG signal irregularity based on different entropy metrics. The statistical parameters of signal envelope amplitude can be used to characterize the temporal fluctuations related to the cartilage pathology. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Joint for deployable structures

    NASA Technical Reports Server (NTRS)

    Craighead, N. D., II; Preliasco, R. J.; Hult, T. D. (Inventor)

    1985-01-01

    A joint is described for connecting a pair of beams to pivot them between positions in alignment or beside one another, which is of light weight and which operates in a controlled manner. The joint includes a pair of fittings and at least one center link having opposite ends pivotally connected to opposite fittings and having axes that pass through centerplates of the fittings. A control link having opposite ends pivotally connected to the different fittings controls their relative orientations, and a toggle assemly holds the fittings in the deployed configuration wherein they are aligned. The fittings have stops that lie on one side of the centerplane opposite the toggle assembly.

  16. Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

    NASA Technical Reports Server (NTRS)

    McWhorter, Bruce B.; Bolton, Doug E.; Hicken, Steve V.; Allred, Larry D.; Cook, Dave J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) uses an internal insulation J-joint design for the mated insulation interface between two assembled RSRM segments. In this assembled (mated) segment configuration, this J-joint design serves as a thermal barrier to prevent hot gases from affecting the case field joint metal surfaces and O-rings. A pressure sensitive adhesive (PSA) provides some adhesion between the two mated insulation surfaces. In 1995, after extensive testing, a new ODC-free PSA (free of ozone depleting chemicals) was selected for flight on RSRM-55 (STS-78). Post-flight inspection revealed that the J-joint, equipped with the new ODC-free PSA, did not perform well. Hot gas seeped inside the J-joint interface. Although not a flight safety threat, the J-joint hot gas intrusion on RSRM-55 was a mystery to the investigators since the PSA had previously worked well on a full-scale static test. A team was assembled to study the J-joint and PSA further. All J-joint design parameters, measured data, and historical performance data were re-reviewed and evaluated by subscale testing and analysis. Although both the ODC-free and old PSA were weakened by humidity, the ODC-free PSA strength was lower to start with. Another RSRM full-scale static test was conducted in 1998 and intentionally duplicated the gas intrusion. This test, along with many concurring tests, showed that if a J-joint was 1) mated with the new ODC-free PSA, 2) exposed to a history of high humidity (Kennedy Space Center levels), and 3) also a joint which experienced significant but normal joint motion (J-joint deformation resulting from motor pressurization dynamics) then that J-joint would open (allow gas intrusion) during motor operation. When all of the data from the analyses, subscale tests, and full-scale tests were considered together, a theory emerged. Most of the joint motion on the RSRM occurs early in motor operation at which point the J-joints are pulled into tension. If the new

  17. Evaluation of tantalum 316 stainless steel transition joints

    NASA Technical Reports Server (NTRS)

    Stoner, D. R.

    1972-01-01

    Tubular transition joints providing a metallurgically bonded connection between tantalum and 316 stainless steel pipe sections were comparatively evaluated for durability under thermal cycling conditions approximating the operation of a SNAP-8 mercury boiler. Both coextruded and vacuum brazed transition joints of 50mm (2 inch) diameter were tested by thermal cycling 100 times between 730 C and 120 C(1350 F and 250 F) in a high vacuum environment. The twelve evaluated transition joints survived the full test sequence without developing leaks, although liquid penetrant bond line indications eventually developed in all specimens. The brazed transition joints exhibited the best dimensional stability and bond line durability.

  18. Metal-on-metal hip joint tribology.

    PubMed

    Dowson, D; Jin, Z M

    2006-02-01

    The basic tribological features of metal-on-metal total hip replacements have been reviewed to facilitate an understanding of the engineering science underpinning the renaissance of these hard-on-hard joints. Metal-on-polymer hip replacements operate in the boundary lubrication regime, thus leading to the design guidance to reduce the femoral head diameter as much as is feasible to minimize frictional torque and volumetric wear. This explains why the gold-standard implant of this form from the past half-century had a diameter of only 22.225 mm (7/8 in). Metal-on-metal implants can operate in the mild mixed lubrication regime in which much of the applied load is supported by elastohydrodynamic films. Correct tribological design leads to remarkably low steady state wear rates. Promotion of the most effective elastohydrodynamic films calls for the largest possible head diameters and the smallest clearances that can reasonably be adopted, consistent with fine surface finishes, good sphericity and minimal structural elastic deformation of the cup on its foundations. This guidance, which is opposite in form to that developed for metal-on-polymer joints, is equally valid for solid (monolithic) metallic heads on metallic femoral stems and surface replacement femoral shells. Laboratory measurements of friction and wear in metal-on-metal joints have confirmed their potential to achieve a very mild form of mixed lubrication. The key lies in the generation of effective elastohydrodynamic lubricating films of adequate thickness compared with the composite roughness of the head and cup. The calculation of the film thickness is by no means easy, but the full procedure is outlined and the use of an empirical formula that displays good agreement with calculations based upon the full numerical solutions is explained. The representation of the lambda ratio, lambda, embracing both film thickness and composite roughness, is described.

  19. Shear fracture of jointed steel plates of bolted joints under impact load

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.; Kobayashi, H.; Shin, H.-S.

    2013-07-01

    The present study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of bolted joints used in a car body, which contributes to crash simulations by CAE. We focus our attention on the shear fracture of the jointed steel plates of lap-bolted joints in the suspension of a car under impact load. Members of lap-bolted joints are modelled as a pair of steel plates connected by a bolt. One of the plates is a specimen subjected to plastic deformation and fracture and the other is a jig subjected to elastic deformation only. Three kinds of steel plate specimens are examined, i.e., a common steel plate with a tensile strength of 270 MPa and high tensile strength steel plates of 440 and 590 MPa used for cars. The impact shear test was performed using the split Hopkinson bar technique for tension impact, together with the static test using a universal testing machine INSTRON 5586. The behaviour of the shear stress and deformation up to rupture taking place in the joint was discussed. The obtained results suggest that a stress-based fracture criterion may be developed for the impact fracture of jointed steel plates of a lap-bolted joint.

  20. Texture characterization for joint compression and classification based on human perception in the wavelet domain.

    PubMed

    Fahmy, Gamal; Black, John; Panchanathan, Sethuraman

    2006-06-01

    Today's multimedia applications demand sophisticated compression and classification techniques in order to store, transmit, and retrieve audio-visual information efficiently. Over the last decade, perceptually based image compression methods have been gaining importance. These methods take into account the abilities (and the limitations) of human visual perception (HVP) when performing compression. The upcoming MPEG 7 standard also addresses the need for succinct classification and indexing of visual content for efficient retrieval. However, there has been no research that has attempted to exploit the characteristics of the human visual system to perform both compression and classification jointly. One area of HVP that has unexplored potential for joint compression and classification is spatial frequency perception. Spatial frequency content that is perceived by humans can be characterized in terms of three parameters, which are: 1) magnitude; 2) phase; and 3) orientation. While the magnitude of spatial frequency content has been exploited in several existing image compression techniques, the novel contribution of this paper is its focus on the use of phase coherence for joint compression and classification in the wavelet domain. Specifically, this paper describes a human visual system-based method for measuring the degree to which an image contains coherent (perceptible) phase information, and then exploits that information to provide joint compression and classification. Simulation results that demonstrate the efficiency of this method are presented.

  1. Development of High Temperature Dissimilar Joint Technology for Fission Surface Power Systems

    NASA Technical Reports Server (NTRS)

    Locci, Ivan E.; Bowman, Cheryl L.; Gabb, Timothy P.

    2009-01-01

    NASA is developing fission surface power (FSP) system technology as a potential option for use on the surface of the moon or Mars. The goal is to design a robust system that takes full advantage of existing materials data bases. One of the key components of the power conversion system is the hot-side Heat Exchanger (HX). One possible design for this heat exchanger requires a joint of the dissimilar metals 316L stainless steel and Inconel 718, which must sustain extended operation at high temperatures. This study compares two joining techniques, brazing and diffusion bonding, in the context of forming the requisite stainless steel to superalloy joint. The microstructures produced by brazing and diffusion bonding, the effect of brazing cycle on the mechanical tensile properties of the alloys, and the strength of several brazed joints will be discussed.

  2. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frear, D.R.; Burchett, S.N.; Rashid, M.M.

    The thermomechanical fatigue failure of solder joints in increasingly becoming an important reliability issue. In this paper we present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. Themore » single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.« less

  3. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  4. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  5. Research on adaptive optics image restoration algorithm based on improved joint maximum a posteriori method

    NASA Astrophysics Data System (ADS)

    Zhang, Lijuan; Li, Yang; Wang, Junnan; Liu, Ying

    2018-03-01

    In this paper, we propose a point spread function (PSF) reconstruction method and joint maximum a posteriori (JMAP) estimation method for the adaptive optics image restoration. Using the JMAP method as the basic principle, we establish the joint log likelihood function of multi-frame adaptive optics (AO) images based on the image Gaussian noise models. To begin with, combining the observed conditions and AO system characteristics, a predicted PSF model for the wavefront phase effect is developed; then, we build up iterative solution formulas of the AO image based on our proposed algorithm, addressing the implementation process of multi-frame AO images joint deconvolution method. We conduct a series of experiments on simulated and real degraded AO images to evaluate our proposed algorithm. Compared with the Wiener iterative blind deconvolution (Wiener-IBD) algorithm and Richardson-Lucy IBD algorithm, our algorithm has better restoration effects including higher peak signal-to-noise ratio ( PSNR) and Laplacian sum ( LS) value than the others. The research results have a certain application values for actual AO image restoration.

  6. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  7. Mechanical Properties of Aluminum-Based Dissimilar Alloy Joints by Power Beams, Arc and FSW Processes

    NASA Astrophysics Data System (ADS)

    Okubo, Michinori; Kon, Tomokuni; Abe, Nobuyuki

    Dissimilar smart joints are useful. In this research, welded quality of dissimilar aluminum alloys of 3 mm thickness by various welding processes and process parameters have been investigated by hardness and tensile tests, and observation of imperfection and microstructure. Base metals used in this study are A1050-H24, A2017-T3, A5083-O, A6061-T6 and A7075-T651. Welding processes used are YAG laser beam, electron beam, metal inert gas arc, tungsten inert gas arc and friction stir welding. The properties of weld zones are affected by welding processes, welding parameters and combination of base metals. Properties of high strength aluminum alloy joints are improved by friction stir welding.

  8. Evaluating and optimizing the operation of the hydropower system in the Upper Yellow River: A general LINGO-based integrated framework.

    PubMed

    Si, Yuan; Li, Xiang; Yin, Dongqin; Liu, Ronghua; Wei, Jiahua; Huang, Yuefei; Li, Tiejian; Liu, Jiahong; Gu, Shenglong; Wang, Guangqian

    2018-01-01

    The hydropower system in the Upper Yellow River (UYR), one of the largest hydropower bases in China, plays a vital role in the energy structure of the Qinghai Power Grid. Due to management difficulties, there is still considerable room for improvement in the joint operation of this system. This paper presents a general LINGO-based integrated framework to study the operation of the UYR hydropower system. The framework is easy to use for operators with little experience in mathematical modeling, takes full advantage of LINGO's capabilities (such as its solving capacity and multi-threading ability), and packs its three layers (the user layer, the coordination layer, and the base layer) together into an integrated solution that is robust and efficient and represents an effective tool for data/scenario management and analysis. The framework is general and can be easily transferred to other hydropower systems with minimal effort, and it can be extended as the base layer is enriched. The multi-objective model that represents the trade-off between power quantity (i.e., maximum energy production) and power reliability (i.e., firm output) of hydropower operation has been formulated. With equivalent transformations, the optimization problem can be solved by the nonlinear programming (NLP) solvers embedded in the LINGO software, such as the General Solver, the Multi-start Solver, and the Global Solver. Both simulation and optimization are performed to verify the model's accuracy and to evaluate the operation of the UYR hydropower system. A total of 13 hydropower plants currently in operation are involved, including two pivotal storage reservoirs on the Yellow River, which are the Longyangxia Reservoir and the Liujiaxia Reservoir. Historical hydrological data from multiple years (2000-2010) are provided as input to the model for analysis. The results are as follows. 1) Assuming that the reservoirs are all in operation (in fact, some reservoirs were not operational or did not

  9. Efficacy of Effects Based Operations on Maoist COIN Operations in India

    DTIC Science & Technology

    2012-04-30

    14, SUBJECT TERMS 15. NUMBER OF PAGES. 49 Naxalite Insurgency, Effects Based Approach/Effects Based Operations, Counterinsurgency in India 16...MAOIST COIN OPERATIONS IN INDIA SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE OF MASTER OF MILJTARY STUDIES MAJOR PRAMOD GAHLOT

  10. "Combined Diagnostic Tool" APPlication to a Retrospective Series of Patients Undergoing Total Joint Revision Surgery.

    PubMed

    Gallazzi, Enrico; Drago, Lorenzo; Baldini, Andrea; Stockley, Ian; George, David A; Scarponi, Sara; Romanò, Carlo L

    2017-01-01

    Background : Differentiating between septic and aseptic joint prosthesis may be challenging, since no single test is able to confirm or rule out infection. The choice and interpretation of the panel of tests performed in any case often relies on empirical evaluation and poorly validated scores. The "Combined Diagnostic Tool (CDT)" App, a smartphone application for iOS, was developed to allow to automatically calculate the probability of having a of periprosthetic joint infection, on the basis of the relative sensitivity and specificity of the positive and negative diagnostic tests performed in any given patient. Objective : The aim of the present study was to apply the CDT software to investigate the ability of the tests routinely performed in three high-volume European centers to diagnose a periprosthetic infection. Methods : This three-center retrospective study included 120 consecutive patients undergoing total hip or knee revision, and included 65 infected patients (Group A) and 55 patients without infection (Group B). The following parameters were evaluated: number and type of positive and negative diagnostic tests performed pre-, intra- and post-operatively and resultant probability calculated by the CDT App of having a peri-prosthetic joint infection, based on pre-, intra- and post-operative combined tests. Results : Serological tests were the most common performed, with an average 2.7 tests per patient for Group A and 2.2 for Group B, followed by joint aspiration (0.9 and 0.8 tests per patient, respectively) and imaging techniques (0.5 and 0.2 test per patient). Mean CDT App calculated probability of having an infection based on pre-operative tests was 79.4% for patients in Group A and 35.7 in Group B. Twenty-nine patients in Group A had > 10% chance of not having an infection, and 29 of Group B had > 10% chance of having an infection. Conclusion : This is the first retrospective study focused on investigating the number and type of tests commonly performed

  11. Evaluation of anticollagen type I antibody titers in synovial fluid of both stifle joints and the left shoulder joint of dogs with unilateral cranial cruciate disease.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2007-03-01

    To evaluate anticollagen type I antibodies in synovial fluid of the affected stifle joint, the contralateral stifle joint, and the left shoulder joint of dogs with unilateral cranial cruciate ligament (CrCL) rupture during an extended period of 12 to 18 months. 13 client-owned dogs with CrCL rupture and 2 sham-operated dogs. All dogs were examined and arthrocentesis of all 3 joints was performed every 6 months after surgery. Synovial fluid samples were tested for anticollagen type I antibodies by use of an ELISA. Dogs with partial CrCL rupture had higher antibody titers than dogs with complete rupture. Six of 13 dogs ruptured the contralateral CrCL during the study, whereby higher antibody titers were found for the stifle joints than for the shoulder joint. Seronegative dogs or dogs with extremely low antibody titers and 2 dogs with high antibody titers did not sustain a CrCL rupture in the contralateral stifle joint. In most dogs that had a CrCL rupture of the contralateral stifle joint, a distinct antibody titer gradient toward the stifle joints was detected, suggesting that there was a local inflammatory process in these joints. However, only a small number of sham-operated dogs were used to calculate the cutoff values used to determine the anticollagen type I antibody titers in these patients. Synovial fluid antibodies against collagen type I alone do not initiate CrCL rupture because not all dogs with high antibody titers sustained a CrCL rupture in the contralateral stifle joint.

  12. Implementation Approach for Plug-in Electric Vehicles at Joint Base Lewis McChord. Task 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schey, Stephen; Francfort, Jim

    2014-12-01

    This study focused on Joint Base Lewis McChord (JBLM), which is located in Washington State. Task 1 consisted of a survey of the non-tactical fleet of vehicles at JBLM to begin the review of vehicle mission assignments and the types of vehicles in service. In Task 2, daily operational characteristics of select vehicles were identified and vehicle movements were recorded in data loggers in order to characterize the vehicles’ missions. In Task 3, the results of the data analysis and observations were provided. Individual observations of the selected vehicles provided the basis for recommendations related to PEV adoption (i.e., whethermore » a battery electric vehicle or plug-in hybrid electric vehicle [collectively referred to as PEVs] can fulfill the mission requirements0, as well as the basis for recommendations related to placement of PEV charging infrastructure. This report focuses on an implementation plan for the near-term adoption of PEVs into the JBLM fleet.« less

  13. Autonomy and couples' joint decision-making in healthcare.

    PubMed

    Osamor, Pauline E; Grady, Christine

    2018-01-11

    Respect for autonomy is a key principle in bioethics. However, respecting autonomy in practice is complex because most people define themselves and make decisions influenced by a complex network of social relationships. The extent to which individual autonomy operates for each partner within the context of decision-making within marital or similar relationships is largely unexplored. This paper explores issues related to decision-making by couples (couples' joint decision-making) for health care and the circumstances under which such a practice should be respected as compatible with autonomous decision-making. We discuss the concept of autonomy as it applies to persons and to actions, human interdependency and gender roles in decision-making, the dynamics and outcomes of couples' joint decision-making, and the ethics of couples' joint decision-making. We believe that the extent to which couples' joint decision-making might be deemed ethically acceptable will vary depending on the context. Given that in many traditional marriages the woman is the less dominant partner, we consider a spectrum of scenarios of couples' joint decision-making about a woman's own health care that move from those that are acceptably autonomous to those that are not consistent with respecting the woman's autonomous decision-making. To the extent that there is evidence that both members of a couple understand a decision, intend it, and that neither completely controls the other, couples' joint decision-making should be viewed as consistent with the principle of respect for the woman's autonomy. At the other end of the spectrum are decisions made by the man without the woman's input, representing domination of one partner by the other. We recommend viewing the dynamics of couples' joint decision-making as existing on a continuum of degrees of autonomy. This continuum-based perspective implies that couples' joint decision-making should not be taken at face value but should be assessed against

  14. Irregular Warfare (IW) Joint Operating Concept (JOC), Version 1.0

    DTIC Science & Technology

    2007-09-11

    disruptive challenges. Key portions of the guidance relating to IW include: • Improving proficiency against irregular challenges. • Redefining past...12 Remarks at the Joint Worldwide Planning Conference, Edelweiss Conference Center Garmisch, Germany, 30 November...Requirements associated with GWOT and IW include: • Steady-state – deter and defend against external transnational terrorist attacks, enable

  15. Joint Force Quarterly. Number 1, Summer 1993

    DTIC Science & Technology

    1993-01-01

    Contributors Joint Force Quarterly A PROFESSIONAL MILITARY JOURNAL Editor-in-Chief Alvin H. Bernstein Executive Editor Patrick M. Cronin Managing Editor Robert...understanding of the integrated employ- ment of land, sea, air, space, and special operations forces. The journal focuses on joint doctrine, coalition...other agency of the Federal Government. Por- tions of this journal are protected by copyright and may not be reproduced or extracted without the

  16. Outcomes of office-based temporomandibular joint arthroscopy: a 5-year retrospective study.

    PubMed

    Hossameldin, R H; McCain, J P

    2018-01-01

    Temporomandibular joint (TMJ) arthroscopy is a minimally invasive surgical approach for intra-articular TMJ diseases. Office-based arthroscopy using the smallest TMJ scope allows for good visualization, as well as the ability to lavage the joint in an office setting. This study aimed to assess the efficacy of an office-based TMJ arthroscopic technique. A retrospective evaluation of 363 patients with a TMJ disorder was performed. These patients underwent office-based arthroscopy using the OnPoint 1.2mm Scope System (Biomet Microfixation, Jacksonville, FL, USA) in Florida, USA, from July 2007. The following outcomes of the procedure were assessed: improvement in painless range of mandibular motion, pain on loading, and functional jaw pain; these were evaluated using a visual analog scale (VAS) over an average follow-up period of 263.81±142.1 days. The statistical analysis was performed using IBM SPSS Statistics version 20. Statistically significant improvements in TMJ pain and function, and other variables (P=0.001) were shown following TMJ arthroscopic lysis and lavage. Office-based arthroscopy using the OnPoint System was demonstrated to be a safe and efficient procedure for the treatment of patients with TMJ disorders as the first level of the algorithm of care. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Train Operations at Track Classes 6 and Higher § 213.351... contraction due to temperature variations. When no-slip, joint-to-rail contact exists by design, the...

  18. A concise evidence-based physical examination for diagnosis of acromioclavicular joint pathology: a systematic review.

    PubMed

    Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank

    2018-02-01

    The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint

  19. Joint Calibration of 3d Laser Scanner and Digital Camera Based on Dlt Algorithm

    NASA Astrophysics Data System (ADS)

    Gao, X.; Li, M.; Xing, L.; Liu, Y.

    2018-04-01

    Design a calibration target that can be scanned by 3D laser scanner while shot by digital camera, achieving point cloud and photos of a same target. A method to joint calibrate 3D laser scanner and digital camera based on Direct Linear Transformation algorithm was proposed. This method adds a distortion model of digital camera to traditional DLT algorithm, after repeating iteration, it can solve the inner and external position element of the camera as well as the joint calibration of 3D laser scanner and digital camera. It comes to prove that this method is reliable.

  20. Atlas-based automatic measurements of the morphology of the tibiofemoral joint

    NASA Astrophysics Data System (ADS)

    Brehler, M.; Thawait, G.; Shyr, W.; Ramsay, J.; Siewerdsen, J. H.; Zbijewski, W.

    2017-03-01

    Purpose: Anatomical metrics of the tibiofemoral joint support assessment of joint stability and surgical planning. We propose an automated, atlas-based algorithm to streamline the measurements in 3D images of the joint and reduce userdependence of the metrics arising from manual identification of the anatomical landmarks. Methods: The method is initialized with coarse registrations of a set of atlas images to the fixed input image. The initial registrations are then refined separately for the tibia and femur and the best matching atlas is selected. Finally, the anatomical landmarks of the best matching atlas are transformed onto the input image by deforming a surface model of the atlas to fit the shape of the tibial plateau in the input image (a mesh-to-volume registration). We apply the method to weight-bearing volumetric images of the knee obtained from 23 subjects using an extremity cone-beam CT system. Results of the automated algorithm were compared to an expert radiologist for measurements of Static Alignment (SA), Medial Tibial Slope (MTS) and Lateral Tibial Slope (LTS). Results: Intra-reader variability as high as 10% for LTS and 7% for MTS (ratio of standard deviation to the mean in repeated measurements) was found for expert radiologist, illustrating the potential benefits of an automated approach in improving the precision of the metrics. The proposed method achieved excellent registration of the atlas mesh to the input volumes. The resulting automated measurements yielded high correlations with expert radiologist, as indicated by correlation coefficients of 0.72 for MTS, 0.8 for LTS, and 0.89 for SA. Conclusions: The automated method for measurement of anatomical metrics of the tibiofemoral joint achieves high correlation with expert radiologist without the need for time consuming and error prone manual selection of landmarks.

  1. Atlas-based automatic measurements of the morphology of the tibiofemoral joint.

    PubMed

    Brehler, M; Thawait, G; Shyr, W; Ramsay, J; Siewerdsen, J H; Zbijewski, W

    2017-02-11

    Anatomical metrics of the tibiofemoral joint support assessment of joint stability and surgical planning. We propose an automated, atlas-based algorithm to streamline the measurements in 3D images of the joint and reduce user-dependence of the metrics arising from manual identification of the anatomical landmarks. The method is initialized with coarse registrations of a set of atlas images to the fixed input image. The initial registrations are then refined separately for the tibia and femur and the best matching atlas is selected. Finally, the anatomical landmarks of the best matching atlas are transformed onto the input image by deforming a surface model of the atlas to fit the shape of the tibial plateau in the input image (a mesh-to-volume registration). We apply the method to weight-bearing volumetric images of the knee obtained from 23 subjects using an extremity cone-beam CT system. Results of the automated algorithm were compared to an expert radiologist for measurements of Static Alignment (SA), Medial Tibial Slope (MTS) and Lateral Tibial Slope (LTS). Intra-reader variability as high as ~10% for LTS and 7% for MTS (ratio of standard deviation to the mean in repeated measurements) was found for expert radiologist, illustrating the potential benefits of an automated approach in improving the precision of the metrics. The proposed method achieved excellent registration of the atlas mesh to the input volumes. The resulting automated measurements yielded high correlations with expert radiologist, as indicated by correlation coefficients of 0.72 for MTS, 0.8 for LTS, and 0.89 for SA. The automated method for measurement of anatomical metrics of the tibiofemoral joint achieves high correlation with expert radiologist without the need for time consuming and error prone manual selection of landmarks.

  2. High-resolution x-ray guided three-dimensional diffuse optical tomography of joint tissues in hand osteoarthritis: Morphological and functional assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan Zhen; Zhang Qizhi; Sobel, Eric S.

    Purpose: The aim of this study was to investigate the potential use of multimodality functional imaging techniques to identify the quantitative optical findings that can be used to distinguish between osteoarthritic and normal finger joints. Methods: Between 2006 and 2009, the distal interphalangeal finger joints from 40 female subjects including 22 patients and 18 healthy controls were examined clinically and scanned by a hybrid imaging system. This system integrated x-ray tomosynthetic setup with a diffuse optical imaging system. Optical absorption and scattering images were recovered based on a regularization-based hybrid reconstruction algorithm. A receiver operating characteristic curve was used tomore » calculate the statistical significance of specific optical features obtained from osteoarthritic and healthy joints groups. Results: The three-dimensional optical and x-ray images captured made it possible to quantify optical properties and joint space width of finger joints. Based on the recovered optical absorption and scattering parameters, the authors observed statistically significant differences between healthy and osteoarthritis finger joints. Conclusions: The statistical results revealed that sensitivity and specificity values up to 92% and 100%, respectively, can be achieved when optical properties of joint tissues were used as classifiers. This suggests that these optical imaging parameters are possible indicators for diagnosing osteoarthritis and monitoring its progression.« less

  3. Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Valish, Dana J.

    2011-01-01

    In 2009 and early 2010, a test was performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design meets the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future space suits. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis and a variance in torque values for some of the tested joints was apparent. Potential variables that could have affected the data were identified and re-testing was conducted in an attempt to eliminate these variables. The results of the retest will be used to determine if further testing and modification is necessary before the method can be validated.

  4. Prosthetic Joint Infections

    PubMed Central

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  5. [Repair and reconstruction for severe fracture and dislocation of ankle joint].

    PubMed

    Yin, Qingwei; Jiang, Yi; Xiao, Lianping; Li, Xiaodong; Fu, Jiaxin; Tian, Yonggang; Han, Liqiang; Liu, Zhi

    2008-06-01

    To summarize the technique and effect of the therapy for severe fracture and dislocation of ankle joint by operation. From March 2003 to February 2006, 76 cases were treated with primary open restoration and internal fixation for dislocated ankle joint fracture, with 47 males and 29 females, with the average age of 36.4 years (ranging from 18 years to 65 years). According to AO criterion, these fresh fractures were classified into 13 cases for type C3-1, 45 cases for type C3-2 and 18 cases for type C3-3. Based on the Gustilo-Anderson standard, 23 open fractures were classified into 17 cases for type II and 6 cases for type III A. The operation was delayed from 1 hours to 24 hours after the injury. All incisions healed at the first stage except 4 cases which delayed union because of simple infection by revision with ointment. A total of 72 cases were followed up, with the average time of 18.5 months (from 12 months to 35 months). The time of bone union was from 12 weeks to 24 weeks. The screws of fixation for lower tibia-fibula joint were found to be ruptured in 2 cases when further consultation was performed in the 16th and 20th week after the operation, respectively, and were broken within 1 year after the operation. These screws were taken out 12 weeks postoperative in 28 cases, while the whole internal fixations of the rest cases were taken out 1 year after the operation. The postoperative function of malleolus extended from 21.7 degrees to 26.8 degrees and flection from 38.5 degrees to 44.7 degrees. Assessed by the American Orthopaedic Foot and Ankle Society Clinical Rating Scales, 23 cases were excellent, 36 good, 13 fair, and the choiceness rate reached 81.94%. These procedures, together with reduction by twist after hospital, open and internal fixation in time, and parenchyma managed with internal fixation, are important to attain satisfactory effect for the treatment of severe fracture and dislocation of ankle joint.

  6. Effects of joints in truss structures

    NASA Technical Reports Server (NTRS)

    Ikegami, R.

    1988-01-01

    The response of truss-type structures for future space applications, such as Large Deployable Reflector (LDR), will be directly affected by joint performance. Some of the objectives of research at BAC were to characterize structural joints, establish analytical approaches that incorporate joint characteristics, and experimentally establish the validity of the analytical approaches. The test approach to characterize joints for both erectable and deployable-type structures was based upon a Force State Mapping Technique. The approach pictorially shows how the nonlinear joint results can be used for equivalent linear analysis. Testing of the Space Station joints developed at LaRC (a hinged joint at 2 Hz and a clevis joint at 2 Hz) successfully revealed the nonlinear characteristics of the joints. The Space Station joints were effectively linear when loaded to plus or minus 500 pounds with a corresponding displacement of about plus or minus 0.0015 inch. It was indicated that good linear joints exist which are compatible with errected structures, but that difficulty may be encountered if nonlinear-type joints are incorporated in the structure.

  7. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

    PubMed

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-12-01

    Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (p< 0.05). The mean tensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint.

  8. Relation between hardness and ultrasonic velocity on pipeline steel welded joints

    NASA Astrophysics Data System (ADS)

    Carreón, H.; Barrera, G.; Natividad, C.; Salazar, M.; Contreras, A.

    2016-04-01

    In general, the ultrasonic techniques have been used to determine the mechanical properties of materials based on their relationship with metallurgical characteristics. In this research work, the relationship between ultrasonic wave velocity, hardness and the microstructure of steel pipeline welded joints is investigated. Measurements of ultrasonic wave velocity were made as a function of the location across the weld. Hardness measurements were performed in an attempt to correlate with ultrasonic response. In addition, the coarse and dendritic grain structure of the weld material is extreme and unpredictably anisotropic. Thus, due to the acoustic anisotropy of the crystal, weld material of studied joints is anisotropic too. Such structure is no longer direction-independent to the ultrasonic wave propagation; therefore, the ultrasonic beam deflects and redirects and the wave front becomes distorted. Thus, the use of conventional ultrasonic testing techniques using fixed beam angles is very limited and the application of conventional ultrasonic phased array techniques becomes desirable. This technique is proposed to assist pipeline operators in estimating the hardness through ultrasonic measures to evaluate the susceptibility to stress sulphide cracking and hydrogen-induced cracking due to hard spots in steel pipeline welded joints in service. Sound wave velocity and hardness measurements have been carried out on a steel welded joint. For each section of the welding, weld bead, fusion zone, heat affected zone and base metal were found to correspond particular values of the ultrasound velocity. These results were correlated with electron microscopy observations of the microstructure and sectorial scan view of welded joints by ultrasonic phased array.

  9. Atlantoaxial manual realignment in a patient with traumatic atlantoaxial joint disruption.

    PubMed

    Goel, Atul; Figueiredo, Antonio; Maheshwari, Shradha; Shah, Abhidha

    2010-05-01

    We report a patient with complex traumatic translatory atlantoaxial dislocation, who we treated by joint exposure and reduction of the dislocation by facet manipulation and subsequent plate and screw atlantoaxial fixation. A 28-year-old male had fallen 7.6m (25 feet), and following the fall had severe neck pain but no neurological deficit. Investigations revealed a fracture at the base of the odontoid process and posterior displacement of the entire atlas over the axis, resulting in a translatory atlantoaxial dislocation. Head traction failed as he developed severe vertigo following its application. The patient was operated upon in a prone position. We opened the atlantoaxial joint and realigned the facets using distraction and manipulation techniques and secured the joint using a plate and screw interarticular method. The patient tolerated the treatment well and was symptom-free after 28 months. Postoperative images showed good craniovertebral alignment. Although technically challenging, direct manipulation of the facets of the atlas and axis can result in excellent craniovertebral realignment.

  10. A digital beamforming processor for the joint DoD/NASA space based radar mission

    NASA Technical Reports Server (NTRS)

    Fischman, Mark A.; Le, Charles; Rosen, Paul A.

    2004-01-01

    The Space Based Radar (SBR) program includes a joint technology demonstration between NASA and the Air Force to design a low-earth orbiting, 2x50 m L-band radar system for both Earth science and intelligence related observations.

  11. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  12. Method for PE Pipes Fusion Jointing Based on TRIZ Contradictions Theory

    NASA Astrophysics Data System (ADS)

    Sun, Jianguang; Tan, Runhua; Gao, Jinyong; Wei, Zihui

    The core of the TRIZ theories is the contradiction detection and solution. TRIZ provided various methods for the contradiction solution, but all that is not systematized. Combined with the technique system conception, this paper summarizes an integration solution method for contradiction solution based on the TRIZ contradiction theory. According to the method, a flowchart of integration solution method for contradiction is given. As a casestudy, method of fusion jointing PE pipe is analysised.

  13. Size effects in tin-based lead-free solder joints: Kinetics of bond formation and mechanical characteristics

    NASA Astrophysics Data System (ADS)

    Abdelhadi, Ousama Mohamed Omer

    Continuous miniaturization of microelectronic interconnects demands smaller joints with comparable microstructural and structural sizes. As the size of joints become smaller, the volume of intermetallics (IMCs) becomes comparable with the joint size. As a result, the kinetics of bond formation changes and the types and thicknesses of IMC phases that form within the constrained region of the bond varies. This dissertation focuses on investigating combination effects of process parameters and size on kinetics of bond formation, resulting microstructure and the mechanical properties of joints that are formed under structurally constrained conditions. An experiment is designed where several process parameters such as time of bonding, temperature, and pressure, and bond thickness as structural chracteristic, are varied at multiple levels. The experiment is then implemented on the process. Scanning electron microscope (SEM) is then utilized to determine the bond thickness, IMC phases and their thicknesses, and morphology of the bonds. Electron backscatter diffraction (EBSD) is used to determine the grain size in different regions, including the bulk solder, and different IMC phases. Physics-based analytical models have been developed for growth kinetics of IMC compounds and are verified using the experimental results. Nanoindentation is used to determine the mechanical behavior of IMC phases in joints in different scales. Four-point bending notched multilayer specimen and four-point bending technique were used to determine fracture toughness of the bonds containing IMCs. Analytical modeling of peeling and shear stresses and fracture toughness in tri-layer four-point bend specimen containing intermetallic layer was developed and was verified and validated using finite element simulation and experimental results. The experiment is used in conjunction with the model to calculate and verify the fracture toughness of Cu6Sn5 IMC materials. As expected two different IMC phases

  14. 2D joint inversion of CSAMT and magnetic data based on cross-gradient theory

    NASA Astrophysics Data System (ADS)

    Wang, Kun-Peng; Tan, Han-Dong; Wang, Tao

    2017-06-01

    A two-dimensional forward and backward algorithm for the controlled-source audio-frequency magnetotelluric (CSAMT) method is developed to invert data in the entire region (near, transition, and far) and deal with the effects of artificial sources. First, a regularization factor is introduced in the 2D magnetic inversion, and the magnetic susceptibility is updated in logarithmic form so that the inversion magnetic susceptibility is always positive. Second, the joint inversion of the CSAMT and magnetic methods is completed with the introduction of the cross gradient. By searching for the weight of the cross-gradient term in the objective function, the mutual influence between two different physical properties at different locations are avoided. Model tests show that the joint inversion based on cross-gradient theory offers better results than the single-method inversion. The 2D forward and inverse algorithm for CSAMT with source can effectively deal with artificial sources and ensures the reliability of the final joint inversion algorithm.

  15. Development of a persistent superconducting joint between Bi-2212/Ag-alloy multifilamentary round wires

    NASA Astrophysics Data System (ADS)

    Chen, Peng; Trociewitz, Ulf P.; Davis, Daniel S.; Bosque, Ernesto S.; Hilton, David K.; Kim, Youngjae; Abraimov, Dmytro V.; Starch, William L.; Jiang, Jianyi; Hellstrom, Eric E.; Larbalestier, David C.

    2017-02-01

    Superconducting joints are one of the key components needed to make Ag-alloy clad Bi2Sr2CaCu2O8+x (Bi-2212) superconducting round wire (RW) successful for high-field, high-homogeneity magnet applications, especially for nuclear magnetic resonance magnets in which persistent current mode operation is highly desired. In this study, a procedure for fabricating superconducting joints between Bi-2212 RWs during coil reaction was developed. Melting temperatures of Bi-2212 powder with different amounts of Ag addition were investigated by differential thermal analysis so as to provide information for selecting the proper joint matrix. Test joints of 1.3 mm dia. wires heat treated in 1 bar flowing oxygen using the typical partial melt Bi-2212 heat treatment (HT) had transport critical currents I c of ˜900 A at 4.2 K and self-field, decreasing to ˜480 A at 14 T evaluated at 0.1 μV cm-1 at 4.2 K. Compared to the I c of the open-ended short conductor samples with identical 1 bar HT, the I c values of the superconducting joint are ˜20% smaller than that of conductor samples measured in parallel field but ˜20% larger than conductor samples measured in perpendicular field. Microstructures examined by scanning electron microscopy clearly showed the formation of a superconducting Bi-2212 interface between the two Bi-2212 RWs. Furthermore, a Bi-2212 RW closed-loop solenoid with a superconducting joint heat treated in 1 bar flowing oxygen showed an estimated joint resistance below 5 × 10-12 Ω based on its field decay rate. This value is sufficiently low to demonstrate the potential for persistent operation of large inductance Bi-2212 coils.

  16. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    PubMed

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  17. Next Generation Community Based Unified Global Modeling System Development and Operational Implementation Strategies at NCEP

    NASA Astrophysics Data System (ADS)

    Tallapragada, V.

    2017-12-01

    NOAA's Next Generation Global Prediction System (NGGPS) has provided the unique opportunity to develop and implement a non-hydrostatic global model based on Geophysical Fluid Dynamics Laboratory (GFDL) Finite Volume Cubed Sphere (FV3) Dynamic Core at National Centers for Environmental Prediction (NCEP), making a leap-step advancement in seamless prediction capabilities across all spatial and temporal scales. Model development efforts are centralized with unified model development in the NOAA Environmental Modeling System (NEMS) infrastructure based on Earth System Modeling Framework (ESMF). A more sophisticated coupling among various earth system components is being enabled within NEMS following National Unified Operational Prediction Capability (NUOPC) standards. The eventual goal of unifying global and regional models will enable operational global models operating at convective resolving scales. Apart from the advanced non-hydrostatic dynamic core and coupling to various earth system components, advanced physics and data assimilation techniques are essential for improved forecast skill. NGGPS is spearheading ambitious physics and data assimilation strategies, concentrating on creation of a Common Community Physics Package (CCPP) and Joint Effort for Data Assimilation Integration (JEDI). Both initiatives are expected to be community developed, with emphasis on research transitioning to operations (R2O). The unified modeling system is being built to support the needs of both operations and research. Different layers of community partners are also established with specific roles/responsibilities for researchers, core development partners, trusted super-users, and operations. Stakeholders are engaged at all stages to help drive the direction of development, resources allocations and prioritization. This talk presents the current and future plans of unified model development at NCEP for weather, sub-seasonal, and seasonal climate prediction applications with special

  18. Results of Operative and Nonoperative Treatment of Rockwood Types III and V Acromioclavicular Joint Dislocation

    PubMed Central

    Joukainen, Antti; Kröger, Heikki; Niemitukia, Lea; Mäkelä, E. Antero; Väätäinen, Urho

    2014-01-01

    Background: The optimal treatment of acute, complete dislocation of the acromioclavicular joint (ACJ) is still unresolved. Purpose: To determine the difference between operative and nonoperative treatment in acute Rockwood types III and V ACJ dislocation. Study Design: Randomized controlled trial; Level of evidence, 2. Methods: In the operative treatment group, the ACJ was reduced and fixed with 2 transarticular Kirschner wires and ACJ ligament suturing. The Kirschner wires were extracted after 6 weeks. Nonoperatively treated patients received a reduction splint for 4 weeks. At the 18- to 20-year follow-up, the Constant, University of California at Los Angeles Shoulder Rating Scale (UCLA), Larsen, and Simple Shoulder Test (SST) scores were obtained, and clinical and radiographic examinations of both shoulders were performed. Results: Twenty-five of 35 potential patients were examined at the 18- to 20-year follow-up. There were 11 patients with Rockwood type III and 14 with type V dislocations. Delayed surgical treatment for ACJ was used in 2 patients during follow-up: 1 in the operatively treated group and 1 in the nonoperatively treated group. Clinically, ACJs were statistically significantly less prominent or unstable in the operative group than in the nonoperative group (normal/prominent/unstable: 9/4/3 and 0/6/3, respectively; P = .02) and in the operative type III (P = .03) but not type V dislocation groups. In operatively and nonoperatively treated patients, the mean Constant scores were 83 and 85, UCLA scores 25 and 27, Larsen scores 11 and 11, and SST scores 11 and 12 at follow-up, respectively. There were no statistically significant differences in type III and type V dislocations. In the radiographic analysis, the ACJ was wider in the nonoperative than the operative group (8.3 vs 3.4 mm; P = .004), and in the type V dislocations (nonoperative vs operative: 8.5 vs 2.4 mm; P = .007). There was no statistically significant difference between study groups in

  19. DEMES rotary joint: theories and applications

    NASA Astrophysics Data System (ADS)

    Wang, Shu; Hao, Zhaogang; Li, Mingyu; Huang, Bo; Sun, Lining; Zhao, Jianwen

    2017-04-01

    As a kind of dielectric elastomer actuators, dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by small voltage-induced strains, which make them an attractive candidate for use as biomimetic robotics. Considering the rotary joint is a basic and common component of many biomimetic robots, we have been fabricated rotary joint by DEMES and developed its performances in the past two years. In this paper, we have discussed the static analysis, dynamics analysis and some characteristics of the DEMES rotary joint. Based on theoretical analysis, some different applications of the DEMES rotary joint were presented, such as a flapping wing, a biomimetic fish and a two-legged walker. All of the robots are fabricated by DEMES rotary joint and can realize some basic biomimetic motions. Comparing with traditional rigid robot, the robot based on DEMES is soft and light, so it has advantage on the collision-resistant.

  20. Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis)

    NASA Astrophysics Data System (ADS)

    Cao, Qian; Thawait, Gaurav; Gang, Grace J.; Zbijewski, Wojciech; Reigel, Thomas; Brown, Tyler; Corner, Brian; Demehri, Shadpour; Siewerdsen, Jeffrey H.

    2015-02-01

    Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a variety of basic limitations of existing 2D and 3D methods. The method models each surface of a joint as a conductor at fixed electrostatic potential and characterizes the intra-articular space in terms of the electric field lines resulting from the solution of Gauss’ Law and the Laplace equation. As a test case, the method was applied to discrimination of healthy and osteoarthritic subjects (N = 39) in 3D images of the knee acquired on an extremity CBCT system. The method demonstrated improved diagnostic performance (area under the receiver operating characteristic curve, AUC > 0.98) compared to simpler methods of quantitative measurement and qualitative image-based assessment by three expert musculoskeletal radiologists (AUC = 0.87, p-value = 0.007). The method is applicable to simple (e.g. the knee or elbow) or multi-axial joints (e.g. the wrist or ankle) and may provide a useful means of quantitatively assessing a variety of joint pathologies.

  1. Effect of gap distance on tensile strength of preceramic base metal solder joints.

    PubMed

    Fattahi, Farnaz; Motamedi, Milad

    2011-01-01

    In order to fabricate prostheses with high accuracy and durability, soldering techniques have been introduced to clinical dentistry. However, these prostheses always fail at their solder joints. The purpose of this study was to evaluate the effect of gap distance on the tensile strength of base metal solder joints. Based on ADA/ISO 9693 specifications for tensile test, 40 specimens were fabricated from a Ni-Cr alloy and cut at the midpoint of 3-mm diameter bar and placed at desired positions by a specially designed device. The specimens were divided into four groups of 10 samples according to the desired solder gap distance: Group1: 0.1mm; Group2: 0.25mm; Group3: 0.5mm; and Group4: 0.75mm. After soldering, specimens were tested for tensile strength by a universal testing machine at a cross-head speed of 0.5mm/min with a preload of 10N. The mean tensile strength values of the groups were 162, 307.8, 206.1 and 336.7 MPa, respectively. The group with 0.75-mm gap had the highest and the group with 0.1-mm gap had the lowest tensile strength. Bonferroni test showed that Group1 and Group4 had statistically different values (P=0.023), but the differences between other groups were not sig-nificant at a significance level of 0.05. There was no direct relationship between increasing soldering gap distance and tensile strength of the solder joints.

  2. [Clinical observation on the effect of joint mobilization in treating elderly patients after distal radius fractures operation].

    PubMed

    Jia, Xue-Feng; Cai, Hong-Xin; Lin, Ge-Sheng; Fang, Ji-Shi; Wang, Yong; Wu, Zhi-Yong; Tu, Xu-Hui

    2017-07-25

    To investigate the effect of joint mobilization on postoperative wrist joint function, pain and grip strength for elderly patients with distal radius fracture. From January 2015 to June 2016, a total of 67 elderly patients with distal radius fracture were randomly divided into routine exercise group and joint mobilization group. Among them, 37 patients in the routine exercise group underwent conventional distal radius fracture postoperative joint function exercise regimen, including 16 males and 21 females with a mean age of (67.8±3.2) years old ranging from 60 to 72 years old;the injured side was dominant in 23 cases and non-dominant in 14 cases;injury mechanism was fall in 26 cases, traffic accident in 11 cases; for AO type, 6 cases were type B3, 18 cases were type C1, 7 cases were type C2, 6 cases was type C3. Other 30 patients in the joint mobilization group underwent joint mobilization on the basis of the routine exercise group including 14 males and 16 females with a mean age of (67.1±4.0) years old ranging from 61 to 74 years old; the injured side was dominant in 21 cases and non-dominant in 9 cases;injury mechanism was fall in 25 cases, traffic accident in 5 cases;for AO type, 8 cases were type B3, 13 cases were type C1, 6 cases were type C2, 9 cases were type C3. The wrist joint activity, Gartland-Werley wrist joint function score, VAS pain score and grip strength were observed at 3 months afrer treatment. After 3 months' treatment, the VAS in the routine exercise group was higher than that of the joint mobilization group ( P <0.05). The grip strength of affected side in both groups were lower than that of contralateral side, but the average grip strength of affected side in joint mobilization group was higher than that in routine exercise group( P <0.05). In routine exercise group, the average angle of flexion, extension, radial deviation were significantly higher than those of joint mobilization group( P <0.05). But ulnar deviation angle in routine

  3. Modelling of subject specific based segmental dynamics of knee joint

    NASA Astrophysics Data System (ADS)

    Nasir, N. H. M.; Ibrahim, B. S. K. K.; Huq, M. S.; Ahmad, M. K. I.

    2017-09-01

    This study determines segmental dynamics parameters based on subject specific method. Five hemiplegic patients participated in the study, two men and three women. Their ages ranged from 50 to 60 years, weights from 60 to 70 kg and heights from 145 to 170 cm. Sample group included patients with different side of stroke. The parameters of the segmental dynamics resembling the knee joint functions measured via measurement of Winter and its model generated via the employment Kane's equation of motion. Inertial parameters in the form of the anthropometry can be identified and measured by employing Standard Human Dimension on the subjects who are in hemiplegia condition. The inertial parameters are the location of centre of mass (COM) at the length of the limb segment, inertia moment around the COM and masses of shank and foot to generate accurate motion equations. This investigation has also managed to dig out a few advantages of employing the table of anthropometry in movement biomechanics of Winter's and Kane's equation of motion. A general procedure is presented to yield accurate measurement of estimation for the inertial parameters for the joint of the knee of certain subjects with stroke history.

  4. Transforming to Effects-Based Operations: Lessons from the United Kingdom Experience

    DTIC Science & Technology

    2008-01-01

    acquisition of the Airborne Stand-off Radar ( ASTOR ) ground surveillance system which links into the American Joint Surveillance and Attack Radar System...Pumas and the navy’s Sea King HC4s are very old and struggling to cope with the climates in which they are now operating. SECTION 4 The ongoing...Vol. 80, No. 1, pp. 49-62. 21. Tom King , House of Commons Parliamentary Debates, Statement on Defence “Options for Change,” July 25, 1990, session

  5. Design of a telerobotic controller with joint torque sensors

    NASA Technical Reports Server (NTRS)

    Jansen, J. F.; Herndon, J. N.

    1990-01-01

    The purpose was to analytically show how to design a joint controller for a telerobotic system when joint torque sensors are available. Other sensors such as actuator position, actuator velocity, joint position, and joint velocity are assumed to be accessible; however, the results will also be useful when only partial measurements are available. The controller presented can be applied to either mode of operation of a manipulator (i.e., teleoperation or robotic). Mechanical manipulators with high levels of friction are assumed. The results are applied to a telerobotic system built for NASA. Very high levels of friction have been reduced using high-gain feedback while avoiding limit cycles.

  6. Structural characterization of a first-generation articulated-truss joint for space crane application

    NASA Technical Reports Server (NTRS)

    Sutter, Thomas R.; Wu, K. Chauncey; Riutort, Kevin T.; Laufer, Joseph B.; Phelps, James E.

    1992-01-01

    A first-generation space crane articulated-truss joint was statically and dynamically characterized in a configuration that approximated an operational environment. The articulated-truss joint was integrated into a test-bed for structural characterization. Static characterization was performed by applying known loads and measuring the corresponding deflections to obtain load-deflection curves. Dynamic characterization was performed using modal testing to experimentally determine the first six mode shapes, frequencies, and modal damping values. Static and dynamic characteristics were also determined for a reference truss that served as a characterization baseline. Load-deflection curves and experimental frequency response functions are presented for the reference truss and the articulated-truss joint mounted in the test-bed. The static and dynamic experimental results are compared with analytical predictions obtained from finite element analyses. Load-deflection response is also presented for one of the linear actuators used in the articulated-truss joint. Finally, an assessment is presented for the predictability of the truss hardware used in the reference truss and articulated-truss joint based upon hardware stiffness properties that were previously obtained during the Precision Segmented Reflector (PSR) Technology Development Program.

  7. Command and Control of Joint Air Operations through Mission Command

    DTIC Science & Technology

    2016-06-01

    and outlines the C2 architecture systems, processes, and philosophy of com- mand required to enable mission command effectively. Mission Command...General Dempsey highlights the fact that “trust is the moral sinew that binds the distributed Joint Force 2020 together” and observes that “unless...con- fident about how their subordinates will make decisions and adapt to the dynamic battlespace environment. Processes, Systems, and Philosophy of

  8. Systemic Operational Design: Enhancing the Joint Operation Planning Process

    DTIC Science & Technology

    2007-05-20

    Epistemological Bumpf of the Way Ahead for Operational Design? p. 42. 79 Stephen R. Covey, The 7 Habits of Highly Effective People . (New York: Fireside...John Wiley and Sons, Ltd. Covey, Stephen R. 1989. The 7 Habits of Highly Effective People . New York: Fireside Publishing. Creveld, Martin Van

  9. Associations between pre-operative radiographic changes and outcomes after total knee joint replacement for osteoarthritis.

    PubMed

    Dowsey, M M; Nikpour, M; Dieppe, P; Choong, P F M

    2012-10-01

    To assess the influence of pre-operative X-ray changes on the response to total knee joint replacement (TKR). We included patients from one centre who underwent primary TKR (n = 478) for osteoarthritis in 2006 and 2007. The International Knee Society score (IKSS) and short form health survey were collected pre-operatively and at 1 and 2 years after surgery. Pre-operative radiographs were read to assess Kellgren and Lawrence (K-L) grading, individual radiographic features using the OARSI atlas, and subchondral bone attrition using the Ahlbach method. The main independent variable was a modified (K-L) grade. The outcome variables were the IKSS pain and function scores. Covariates included demographic features, co-morbidities, baseline pain and function, prosthesis type, and the use of patella resurfacing. Multivariable linear regression models were created to assess the relationships between pre-operative X-ray findings and pain and function outcomes. On average, pain and function improved greatly following surgery. However, pain relief was unsatisfactory in about 30%, and functional improvement suboptimal in about 50%. OR (95% CI) for ongoing moderate-severe pain at 12 months for modified K-L grades; <3: 5.39 (1.23-15.69), 3a: 2.62 (1.21-5.67), 3b: 1.81 (1.00-3.26), 4a: 2.06 (1.05-4.05) when compared to 4b. OR (95% CI) for poor function at 12 months were; 3a: 2.81 (1.23-6.39) and 4a: 2.45 (1.22-4.91), when compared to 4b. Patients with more severe radiographic knee damage at the time of surgery are most likely to have substantial gains in terms of both pain relief and improved function as a result of a TKR. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Vascular risk reduction during anterior surgical approach sacroiliac joint plating.

    PubMed

    Alla, Sreenivasa R; Roberts, Craig S; Ojike, Nwakile I

    2013-02-01

    Open reduction and internal fixation of sacroiliac (SI) joint is often performed through an anterior approach. However, there were no studies to our knowledge which described the "at risk area" for injury to the nutrient artery as it relates to open reduction and internal fixation of the SI joint. The purpose of this study was to determine the "at risk area" for the nutrient artery during anterior surgical approaches to the SI joint and to define the safe location of the plate for SI joint fixation. Six right and five left hemipelvises (three male and three female cadavers) were dissected with a mean age of 72 years (range, 51-90 years). Three bony landmarks including the pelvic brim, anterior SI joint line, and the anterior superior iliac spine (ASIS) were identified to quantify the measurements. Three different measurements were taken: from the nutrient foramen to the anterior SI joint line; from the nutrient foramen to the nearest point on the pelvic brim; from the nutrient foramen to ASIS using a flexible ruler with a 1mm base. The nutrient artery courses across the SI joint to enter into the nutrient foramen. Whilst exposing the internal surface of the SI joint, the nutrient foramen was identified at a mean distance of 88.1mm medial to ASIS, 20.1mm above the pelvic brim, and 20.1mm lateral to SI joint. The variability of the location of the nutrient foramen was identified and was located from 80mm to 95mm medial to the ASIS, 12mm to 25mm lateral to the SI joint, and 16mm to 30mm above the pelvic brim. Familiarity of the vasculature of the internal pelvis is of utmost importance for the surgeon when considering operative fixation of the anterior SI joint. We were able to identify the relation of the nutrient artery to the anatomic landmarks of the internal pelvis and to define the "at risk area" for the nutrient artery. We believe increased understanding of the anatomy of the nutrient artery will aid in the avoidance of vascular complications during internal

  11. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints

    PubMed Central

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-01-01

    Statement of the Problem Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. Purpose The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. Materials and Method A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (p< 0.05). Results The mean tensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Conclusion Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint. PMID:26636118

  12. Perfect commuting-operator strategies for linear system games

    NASA Astrophysics Data System (ADS)

    Cleve, Richard; Liu, Li; Slofstra, William

    2017-01-01

    Linear system games are a generalization of Mermin's magic square game introduced by Cleve and Mittal. They show that perfect strategies for linear system games in the tensor-product model of entanglement correspond to finite-dimensional operator solutions of a certain set of non-commutative equations. We investigate linear system games in the commuting-operator model of entanglement, where Alice and Bob's measurement operators act on a joint Hilbert space, and Alice's operators must commute with Bob's operators. We show that perfect strategies in this model correspond to possibly infinite-dimensional operator solutions of the non-commutative equations. The proof is based around a finitely presented group associated with the linear system which arises from the non-commutative equations.

  13. Locality constrained joint dynamic sparse representation for local matching based face recognition.

    PubMed

    Wang, Jianzhong; Yi, Yugen; Zhou, Wei; Shi, Yanjiao; Qi, Miao; Zhang, Ming; Zhang, Baoxue; Kong, Jun

    2014-01-01

    Recently, Sparse Representation-based Classification (SRC) has attracted a lot of attention for its applications to various tasks, especially in biometric techniques such as face recognition. However, factors such as lighting, expression, pose and disguise variations in face images will decrease the performances of SRC and most other face recognition techniques. In order to overcome these limitations, we propose a robust face recognition method named Locality Constrained Joint Dynamic Sparse Representation-based Classification (LCJDSRC) in this paper. In our method, a face image is first partitioned into several smaller sub-images. Then, these sub-images are sparsely represented using the proposed locality constrained joint dynamic sparse representation algorithm. Finally, the representation results for all sub-images are aggregated to obtain the final recognition result. Compared with other algorithms which process each sub-image of a face image independently, the proposed algorithm regards the local matching-based face recognition as a multi-task learning problem. Thus, the latent relationships among the sub-images from the same face image are taken into account. Meanwhile, the locality information of the data is also considered in our algorithm. We evaluate our algorithm by comparing it with other state-of-the-art approaches. Extensive experiments on four benchmark face databases (ORL, Extended YaleB, AR and LFW) demonstrate the effectiveness of LCJDSRC.

  14. The Rationale for Joint Mobilization.

    ERIC Educational Resources Information Center

    Burkhardt, Sandy

    This paper presents an overview of the functions of connective tissue and the mechanisms of joint injury and contracture formation in relation to therapeutic exercise. The components of connective tissue operation are explained, including fibroblasts, macrophages, plasma cells, and collagen. An examination of the histology of connective tissue as…

  15. Effect of Nd:YAG laser beam welding on weld morphology and mechanical properties of Ti-6Al-4V butt joints and T-joints

    NASA Astrophysics Data System (ADS)

    Kashaev, Nikolai; Ventzke, Volker; Fomichev, Vadim; Fomin, Fedor; Riekehr, Stefan

    2016-11-01

    A Nd:YAG single-sided laser beam welding process study for Ti-6Al-4V butt joints and T-joints was performed to investigate joining techniques with regard to the process-weld morphology relationship. An alloy compatible filler wire was used to avoid underfills and undercuts. The quality of the butt joints and T-joints was characterized in terms of weld morphology, microstructure and mechanical properties. Joints with regular shapes, without visible cracks, pores, and geometrical defects were achieved. Tensile tests revealed high joint integrity in terms of strength and ductility for both the butt joint and T-joint geometries. Both the butt joints and T-joints showed base material levels of strength. The mechanical performance of T-joints was also investigated using pull-out tests. The performance of the T-joints in such tests was sensitive to the shape and morphology of the welds. Fracture always occurred in the weld without any plastic deformation in the base material outside the weld.

  16. Evaluating and optimizing the operation of the hydropower system in the Upper Yellow River: A general LINGO-based integrated framework

    PubMed Central

    Si, Yuan; Liu, Ronghua; Wei, Jiahua; Huang, Yuefei; Li, Tiejian; Liu, Jiahong; Gu, Shenglong; Wang, Guangqian

    2018-01-01

    The hydropower system in the Upper Yellow River (UYR), one of the largest hydropower bases in China, plays a vital role in the energy structure of the Qinghai Power Grid. Due to management difficulties, there is still considerable room for improvement in the joint operation of this system. This paper presents a general LINGO-based integrated framework to study the operation of the UYR hydropower system. The framework is easy to use for operators with little experience in mathematical modeling, takes full advantage of LINGO’s capabilities (such as its solving capacity and multi-threading ability), and packs its three layers (the user layer, the coordination layer, and the base layer) together into an integrated solution that is robust and efficient and represents an effective tool for data/scenario management and analysis. The framework is general and can be easily transferred to other hydropower systems with minimal effort, and it can be extended as the base layer is enriched. The multi-objective model that represents the trade-off between power quantity (i.e., maximum energy production) and power reliability (i.e., firm output) of hydropower operation has been formulated. With equivalent transformations, the optimization problem can be solved by the nonlinear programming (NLP) solvers embedded in the LINGO software, such as the General Solver, the Multi-start Solver, and the Global Solver. Both simulation and optimization are performed to verify the model’s accuracy and to evaluate the operation of the UYR hydropower system. A total of 13 hydropower plants currently in operation are involved, including two pivotal storage reservoirs on the Yellow River, which are the Longyangxia Reservoir and the Liujiaxia Reservoir. Historical hydrological data from multiple years (2000–2010) are provided as input to the model for analysis. The results are as follows. 1) Assuming that the reservoirs are all in operation (in fact, some reservoirs were not operational or did

  17. Evaluation of Brazed Joints Using Failure Assessment Diagram

    NASA Technical Reports Server (NTRS)

    Flom, Yury

    2012-01-01

    Fitness-for service approach was used to perform structural analysis of the brazed joints consisting of several base metal / filler metal combinations. Failure Assessment Diagrams (FADs) based on tensile and shear stress ratios were constructed and experimentally validated. It was shown that such FADs can provide a conservative estimate of safe combinations of stresses in the brazed joints. Based on this approach, Margins of Safety (MS) of the brazed joints subjected to multi-axial loading conditions can be evaluated..

  18. Multi-channel EEG-based sleep stage classification with joint collaborative representation and multiple kernel learning.

    PubMed

    Shi, Jun; Liu, Xiao; Li, Yan; Zhang, Qi; Li, Yingjie; Ying, Shihui

    2015-10-30

    Electroencephalography (EEG) based sleep staging is commonly used in clinical routine. Feature extraction and representation plays a crucial role in EEG-based automatic classification of sleep stages. Sparse representation (SR) is a state-of-the-art unsupervised feature learning method suitable for EEG feature representation. Collaborative representation (CR) is an effective data coding method used as a classifier. Here we use CR as a data representation method to learn features from the EEG signal. A joint collaboration model is established to develop a multi-view learning algorithm, and generate joint CR (JCR) codes to fuse and represent multi-channel EEG signals. A two-stage multi-view learning-based sleep staging framework is then constructed, in which JCR and joint sparse representation (JSR) algorithms first fuse and learning the feature representation from multi-channel EEG signals, respectively. Multi-view JCR and JSR features are then integrated and sleep stages recognized by a multiple kernel extreme learning machine (MK-ELM) algorithm with grid search. The proposed two-stage multi-view learning algorithm achieves superior performance for sleep staging. With a K-means clustering based dictionary, the mean classification accuracy, sensitivity and specificity are 81.10 ± 0.15%, 71.42 ± 0.66% and 94.57 ± 0.07%, respectively; while with the dictionary learned using the submodular optimization method, they are 80.29 ± 0.22%, 71.26 ± 0.78% and 94.38 ± 0.10%, respectively. The two-stage multi-view learning based sleep staging framework outperforms all other classification methods compared in this work, while JCR is superior to JSR. The proposed multi-view learning framework has the potential for sleep staging based on multi-channel or multi-modality polysomnography signals. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Assessment and prediction of inter-joint upper limb movement correlations based on kinematic analysis and statistical regression

    NASA Astrophysics Data System (ADS)

    Toth-Tascau, Mirela; Balanean, Flavia; Krepelka, Mircea

    2013-10-01

    Musculoskeletal impairment of the upper limb can cause difficulties in performing basic daily activities. Three dimensional motion analyses can provide valuable data of arm movement in order to precisely determine arm movement and inter-joint coordination. The purpose of this study was to develop a method to evaluate the degree of impairment based on the influence of shoulder movements in the amplitude of elbow flexion and extension based on the assumption that a lack of motion of the elbow joint will be compensated by an increased shoulder activity. In order to develop and validate a statistical model, one healthy young volunteer has been involved in the study. The activity of choice simulated blowing the nose, starting from a slight flexion of the elbow and raising the hand until the middle finger touches the tip of the nose and return to the start position. Inter-joint coordination between the elbow and shoulder movements showed significant correlation. Statistical regression was used to fit an equation model describing the influence of shoulder movements on the elbow mobility. The study provides a brief description of the kinematic analysis protocol and statistical models that may be useful in describing the relation between inter-joint movements of daily activities.

  20. Emergence of Joint Attention through Bootstrap Learning based on the Mechanisms of Visual Attention and Learning with Self-evaluation

    NASA Astrophysics Data System (ADS)

    Nagai, Yukie; Hosoda, Koh; Morita, Akio; Asada, Minoru

    This study argues how human infants acquire the ability of joint attention through interactions with their caregivers from a viewpoint of cognitive developmental robotics. In this paper, a mechanism by which a robot acquires sensorimotor coordination for joint attention through bootstrap learning is described. Bootstrap learning is a process by which a learner acquires higher capabilities through interactions with its environment based on embedded lower capabilities even if the learner does not receive any external evaluation nor the environment is controlled. The proposed mechanism for bootstrap learning of joint attention consists of the robot's embedded mechanisms: visual attention and learning with self-evaluation. The former is to find and attend to a salient object in the field of the robot's view, and the latter is to evaluate the success of visual attention, not joint attention, and then to learn the sensorimotor coordination. Since the object which the robot looks at based on visual attention does not always correspond to the object which the caregiver is looking at in an environment including multiple objects, the robot may have incorrect learning situations for joint attention as well as correct ones. However, the robot is expected to statistically lose the learning data of the incorrect ones as outliers because of its weaker correlation between the sensor input and the motor output than that of the correct ones, and consequently to acquire appropriate sensorimotor coordination for joint attention even if the caregiver does not provide any task evaluation to the robot. The experimental results show the validity of the proposed mechanism. It is suggested that the proposed mechanism could explain the developmental mechanism of infants' joint attention because the learning process of the robot's joint attention can be regarded as equivalent to the developmental process of infants' one.

  1. A web-based system for neural network based classification in temporomandibular joint osteoarthritis.

    PubMed

    de Dumast, Priscille; Mirabel, Clément; Cevidanes, Lucia; Ruellas, Antonio; Yatabe, Marilia; Ioshida, Marcos; Ribera, Nina Tubau; Michoud, Loic; Gomes, Liliane; Huang, Chao; Zhu, Hongtu; Muniz, Luciana; Shoukri, Brandon; Paniagua, Beatriz; Styner, Martin; Pieper, Steve; Budin, Francois; Vimort, Jean-Baptiste; Pascal, Laura; Prieto, Juan Carlos

    2018-07-01

    The purpose of this study is to describe the methodological innovations of a web-based system for storage, integration and computation of biomedical data, using a training imaging dataset to remotely compute a deep neural network classifier of temporomandibular joint osteoarthritis (TMJOA). This study imaging dataset consisted of three-dimensional (3D) surface meshes of mandibular condyles constructed from cone beam computed tomography (CBCT) scans. The training dataset consisted of 259 condyles, 105 from control subjects and 154 from patients with diagnosis of TMJ OA. For the image analysis classification, 34 right and left condyles from 17 patients (39.9 ± 11.7 years), who experienced signs and symptoms of the disease for less than 5 years, were included as the testing dataset. For the integrative statistical model of clinical, biological and imaging markers, the sample consisted of the same 17 test OA subjects and 17 age and sex matched control subjects (39.4 ± 15.4 years), who did not show any sign or symptom of OA. For these 34 subjects, a standardized clinical questionnaire, blood and saliva samples were also collected. The technological methodologies in this study include a deep neural network classifier of 3D condylar morphology (ShapeVariationAnalyzer, SVA), and a flexible web-based system for data storage, computation and integration (DSCI) of high dimensional imaging, clinical, and biological data. The DSCI system trained and tested the neural network, indicating 5 stages of structural degenerative changes in condylar morphology in the TMJ with 91% close agreement between the clinician consensus and the SVA classifier. The DSCI remotely ran with a novel application of a statistical analysis, the Multivariate Functional Shape Data Analysis, that computed high dimensional correlations between shape 3D coordinates, clinical pain levels and levels of biological markers, and then graphically displayed the computation results. The findings of this

  2. Padalka and Polansky in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007430 (21 July 2009) --- Astronaut Mark Polansky (right) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  3. Polansky and Padalka in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007453 (21 July 2009) --- Astronaut Mark Polansky (left) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  4. Microstructural characterisation of friction stir welding joints of mild steel to Ni-based alloy 625

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rodriguez, J.; University of Campinas; Ramirez, A.J., E-mail: ramirezlondono.1@osu.edu

    2015-12-15

    In this study, 6-mm-thick mild steel and Ni-based alloy 625 plates were friction stir welded using a tool rotational speed of 300 rpm and a travel speed of 100 mm·min{sup −1}. A microstructural characterisation of the dissimilar butt joint was performed using optical microscopy, scanning and transmission electron microscopy, and energy dispersive X-ray spectroscopy (XEDS). Six different weld zones were found. In the steel, the heat-affected zone (HAZ) was divided into three zones and was composed of ferrite, pearlite colonies with different morphologies, degenerated regions of pearlite and allotriomorphic and Widmanstätten ferrite. The stir zone (SZ) of the steel showedmore » a coarse microstructure consisting of allotriomorphic and Widmanstätten ferrite, degenerate pearlite and MA constituents. In the Ni-based alloy 625, the thermo-mechanically affected zone (TMAZ) showed deformed grains and redistribution of precipitates. In the SZ, the high deformation and temperature produced a recrystallised microstructure, as well as fracture and redistribution of MC precipitates. The M{sub 23}C{sub 6} precipitates, present in the base material, were also redistributed in the stir zone of the Ni-based alloy. TMAZ in the steel and HAZ in the Ni-based alloy could not be identified. The main restorative mechanisms were discontinuous dynamic recrystallisation in the steel, and discontinuous and continuous dynamic recrystallisation in the Ni-based alloy. The interface region between the steel and the Ni-based alloy showed a fcc microstructure with NbC carbides and an average length of 2.0 μm. - Highlights: • Comprehensive microstructural characterisation of dissimilar joints of mild steel to Ni-based alloy • Friction stir welding of joints of mild steel to Ni-based alloy 625 produces sound welds. • The interface region showed deformed and recrystallised fcc grains with NbC carbides and a length of 2.0 μm.« less

  5. Optimal Synthesis of the Joint Unitary Evolutions

    NASA Astrophysics Data System (ADS)

    Wei, Hai-Rui; Alsaedi, Ahmed; Hobiny, Aatef; Deng, Fu-Guo; Hu, Hui; Zhang, Dun

    2018-07-01

    Joint unitary operations play a central role in quantum communication and computation. We give a quantum circuit for implementing a type of unconstructed useful joint unitary evolutions in terms of controlled-NOT (CNOT) gates and single-qubit rotations. Our synthesis is optimal and possible in experiment. Two CNOT gates and seven R x , R y or R z rotations are required for our synthesis, and the arbitrary parameter contained in the evolutions can be controlled by local Hamiltonian or external fields.

  6. Optimal Synthesis of the Joint Unitary Evolutions

    NASA Astrophysics Data System (ADS)

    Wei, Hai-Rui; Alsaedi, Ahmed; Hobiny, Aatef; Deng, Fu-Guo; Hu, Hui; Zhang, Dun

    2018-03-01

    Joint unitary operations play a central role in quantum communication and computation. We give a quantum circuit for implementing a type of unconstructed useful joint unitary evolutions in terms of controlled-NOT (CNOT) gates and single-qubit rotations. Our synthesis is optimal and possible in experiment. Two CNOT gates and seven R x , R y or R z rotations are required for our synthesis, and the arbitrary parameter contained in the evolutions can be controlled by local Hamiltonian or external fields.

  7. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  8. Operational Intelligence in Irregular Warfare: Organized to the Task or to the Technology

    DTIC Science & Technology

    2009-10-23

    50. 9 CJCS, Joint Operations, Change 1 , JP 3 -0 (Washington, DC: CJCS, 13 February 2008), I-8 to I-9. 10 CJCS, Counterinsurgency Operations, JP 3 -24...Warfighting Publication (MCWP) 3 -33.5 (Washington, DC: Government Printing Office, 15 December 2006), 1 -26. 13 David Rohde, “Army Enlists Anthropology in...Joint Intelligence. Joint Publication (JP) 2-0. Washington, DC: CJCS, 22 June 2007. ______. Joint Operations. Change 1 . JP 3 -0. Washington, DC

  9. Effect of Gap Distance on Tensile Strength of Preceramic Base Metal Solder Joints

    PubMed Central

    Fattahi, Farnaz; Motamedi, Milad

    2011-01-01

    Background and aims In order to fabricate prostheses with high accuracy and durability, soldering techniques have been introduced to clinical dentistry. However, these prostheses always fail at their solder joints. The purpose of this study was to evaluate the effect of gap distance on the tensile strength of base metal solder joints. Materials and methods Based on ADA/ISO 9693 specifications for tensile test, 40 specimens were fabricated from a Ni-Cr alloy and cut at the midpoint of 3-mm diameter bar and placed at desired positions by a specially designed device. The specimens were divided into four groups of 10 samples according to the desired solder gap distance: Group1: 0.1mm; Group2: 0.25mm; Group3: 0.5mm; and Group4: 0.75mm. After soldering, specimens were tested for tensile strength by a universal testing machine at a cross-head speed of 0.5mm/min with a preload of 10N. Results The mean tensile strength values of the groups were 162, 307.8, 206.1 and 336.7 MPa, respectively. The group with 0.75-mm gap had the highest and the group with 0.1-mm gap had the lowest tensile strength. Bonferroni test showed that Group1 and Group4 had statistically different values (P=0.023), but the differences between other groups were not sig-nificant at a significance level of 0.05. Conclusion There was no direct relationship between increasing soldering gap distance and tensile strength of the solder joints. PMID:22991610

  10. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    PubMed

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as < 50%, 50 - 80%, and > 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported

  11. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  12. Assessment for Operator Confidence in Automated Space Situational Awareness and Satellite Control Systems

    NASA Astrophysics Data System (ADS)

    Gorman, J.; Voshell, M.; Sliva, A.

    2016-09-01

    The United States is highly dependent on space resources to support military, government, commercial, and research activities. Satellites operate at great distances, observation capacity is limited, and operator actions and observations can be significantly delayed. Safe operations require support systems that provide situational understanding, enhance decision making, and facilitate collaboration between human operators and system automation both in-the-loop, and on-the-loop. Joint cognitive systems engineering (JCSE) provides a rich set of methods for analyzing and informing the design of complex systems that include both human decision-makers and autonomous elements as coordinating teammates. While, JCSE-based systems can enhance a system analysts' understanding of both existing and new system processes, JCSE activities typically occur outside of traditional systems engineering (SE) methods, providing sparse guidance about how systems should be implemented. In contrast, the Joint Director's Laboratory (JDL) information fusion model and extensions, such as the Dual Node Network (DNN) technical architecture, provide the means to divide and conquer such engineering and implementation complexity, but are loosely coupled to specialized organizational contexts and needs. We previously describe how Dual Node Decision Wheels (DNDW) extend the DNN to integrate JCSE analysis and design with the practicalities of system engineering and implementation using the DNN. Insights from Rasmussen's JCSE Decision Ladders align system implementation with organizational structures and processes. In the current work, we present a novel approach to assessing system performance based on patterns occurring in operational decisions that are documented by JCSE processes as traces in a decision ladder. In this way, system assessment is closely tied not just to system design, but the design of the joint cognitive system that includes human operators, decision-makers, information systems, and

  13. Infrared target recognition based on improved joint local ternary pattern

    NASA Astrophysics Data System (ADS)

    Sun, Junding; Wu, Xiaosheng

    2016-05-01

    This paper presents a simple, efficient, yet robust approach, named joint orthogonal combination of local ternary pattern, for automatic forward-looking infrared target recognition. It gives more advantages to describe the macroscopic textures and microscopic textures by fusing variety of scales than the traditional LBP-based methods. In addition, it can effectively reduce the feature dimensionality. Further, the rotation invariant and uniform scheme, the robust LTP, and soft concave-convex partition are introduced to enhance its discriminative power. Experimental results demonstrate that the proposed method can achieve competitive results compared with the state-of-the-art methods.

  14. 75 FR 55575 - Joint Public Roundtable To Discuss Data for Swaps and Security-Based Swaps, Swap Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-13

    ...; File No. 4-611] Joint Public Roundtable To Discuss Data for Swaps and Security- Based Swaps, Swap Data Repositories, Security-Based Swap Data Repositories, and Real-Time Public Reporting AGENCY: Commodity Futures... public roundtable discussion at which invited participants will discuss data for swaps and security-based...

  15. Evaluation of pipe-type cable joint restraint systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silver, D.A.; Seman, G.W.

    1990-03-01

    the purpose of this project was to evaluate two systems for restraining the movement of 345kV high-pressure oil-filled (HPOF) cable joints during load cycling. Problems with joints and adjacent cables due to thermomechanical bending (TMB) experienced by the Consolidated Edison Company of New York and Public Service Electric Gas Company of New Jersey are reviewed. Some approaches to reducing or preventing TMB induced damage to HPOF pipe type cable joints are discussed. The design and operation of a special test apparatus for simulating TMB effects under laboratory conditions is described. One of the two joint restraint systems evaluated under thismore » project was developed by PSE G and employed wedging devices, which could be retrofitted into existing installations, that limited the longitudinal movement of the joints during load cycling. The other system developed by Pirelli Cable Corporation applied the restraining force to the cylindrical portion of the hand applied joint insulation by means of support spiders and steel rods attached to the reducer faces. The test results show that the PSE G restraint system can effectively limit joint longitudinal movement while causing a minimal amount of mechanical disturbance to the joint stress cones. The test results obtained with the PCC system are inconclusive and indicate that further refinement and testing are required to demonstrate the effectiveness of this promising joint restraint system.« less

  16. Numerical simulation of artificial hip joint motion based on human age factor

    NASA Astrophysics Data System (ADS)

    Ramdhani, Safarudin; Saputra, Eko; Jamari, J.

    2018-05-01

    Artificial hip joint is a prosthesis (synthetic body part) which usually consists of two or more components. Replacement of the hip joint due to the occurrence of arthritis, ordinarily patients aged or older. Numerical simulation models are used to observe the range of motion in the artificial hip joint, the range of motion of joints used as the basis of human age. Finite- element analysis (FEA) is used to calculate stress von mises in motion and observes a probability of prosthetic impingement. FEA uses a three-dimensional nonlinear model and considers the position variation of acetabular liner cups. The result of numerical simulation shows that FEA method can be used to analyze the performance calculation of the artificial hip joint at this time more accurate than conventional method.

  17. Workshop Report: Joint Requirements. Oversight Council Process.

    DTIC Science & Technology

    1996-02-28

    provides media for professional exchange and peer criticism among students, theoreticians, practitioners, and users of military operations research. These... exchange of ideas and methods. involvement in the annual Joint Warfare Inter- Subsequent efforts could include multiple operability Demonstrations (JWID...forums for exchange of ideas at the working level, clear, visible relations but studies and analysis opportunities as well. between the JWCAs need to

  18. Unity of Effort in Joint Information Operations

    DTIC Science & Technology

    2002-12-01

    of strategic intent , strategic architecture, 80 JFQ / Winter 2002–03 if the Nation conducts information operations, the military would not be the...responsible for setting the strategic intent of infor- mation operations. This intent implies a particular point of view on the long-term environment in...which an organization hopes to build a competi- tive position over time. Considering strategic ar- chitecture the brain and strategic intent the heart

  19. A Model-Based Joint Identification of Differentially Expressed Genes and Phenotype-Associated Genes

    PubMed Central

    Seo, Minseok; Shin, Su-kyung; Kwon, Eun-Young; Kim, Sung-Eun; Bae, Yun-Jung; Lee, Seungyeoun; Sung, Mi-Kyung; Choi, Myung-Sook; Park, Taesung

    2016-01-01

    Over the last decade, many analytical methods and tools have been developed for microarray data. The detection of differentially expressed genes (DEGs) among different treatment groups is often a primary purpose of microarray data analysis. In addition, association studies investigating the relationship between genes and a phenotype of interest such as survival time are also popular in microarray data analysis. Phenotype association analysis provides a list of phenotype-associated genes (PAGs). However, it is sometimes necessary to identify genes that are both DEGs and PAGs. We consider the joint identification of DEGs and PAGs in microarray data analyses. The first approach we used was a naïve approach that detects DEGs and PAGs separately and then identifies the genes in an intersection of the list of PAGs and DEGs. The second approach we considered was a hierarchical approach that detects DEGs first and then chooses PAGs from among the DEGs or vice versa. In this study, we propose a new model-based approach for the joint identification of DEGs and PAGs. Unlike the previous two-step approaches, the proposed method identifies genes simultaneously that are DEGs and PAGs. This method uses standard regression models but adopts different null hypothesis from ordinary regression models, which allows us to perform joint identification in one-step. The proposed model-based methods were evaluated using experimental data and simulation studies. The proposed methods were used to analyze a microarray experiment in which the main interest lies in detecting genes that are both DEGs and PAGs, where DEGs are identified between two diet groups and PAGs are associated with four phenotypes reflecting the expression of leptin, adiponectin, insulin-like growth factor 1, and insulin. Model-based approaches provided a larger number of genes, which are both DEGs and PAGs, than other methods. Simulation studies showed that they have more power than other methods. Through analysis of

  20. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  1. Fatigue limits of titanium-bar joints made with the laser and the electric resistance welding techniques: microstructural characterization and hardness properties.

    PubMed

    Degidi, Marco; Nardi, Diego; Morri, Alessandro; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio

    2017-09-01

    Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).

  2. Rescuing Joint Personnel Recovery: Using Air Force Capability to Address Joint Shortfalls

    DTIC Science & Technology

    2011-06-01

    of an IP, the IP is not successfully reintegrated or the lessons learned are not incorporated into other operations. Adversaries will benefit from...Washington, D.C.: Office of Air Force History , United States Air Force, 1980, 117. 47 Durant , Michael J. In the Company of Heroes, Penguin Group... Lessons Learned, 22 September 2005, 3. 2 US Joint Task Force Katrina. The Federal Response to Hurricane Katrina Lessons Learned, February 2006, 54

  3. Joint Power Charging and Routing in Wireless Rechargeable Sensor Networks

    PubMed Central

    Jia, Jie; Chen, Jian; Deng, Yansha; Wang, Xingwei; Aghvami, Abdol-Hamid

    2017-01-01

    The development of wireless power transfer (WPT) technology has inspired the transition from traditional battery-based wireless sensor networks (WSNs) towards wireless rechargeable sensor networks (WRSNs). While extensive efforts have been made to improve charging efficiency, little has been done for routing optimization. In this work, we present a joint optimization model to maximize both charging efficiency and routing structure. By analyzing the structure of the optimization model, we first decompose the problem and propose a heuristic algorithm to find the optimal charging efficiency for the predefined routing tree. Furthermore, by coding the many-to-one communication topology as an individual, we further propose to apply a genetic algorithm (GA) for the joint optimization of both routing and charging. The genetic operations, including tree-based recombination and mutation, are proposed to obtain a fast convergence. Our simulation results show that the heuristic algorithm reduces the number of resident locations and the total moving distance. We also show that our proposed algorithm achieves a higher charging efficiency compared with existing algorithms. PMID:28991200

  4. Joint Power Charging and Routing in Wireless Rechargeable Sensor Networks.

    PubMed

    Jia, Jie; Chen, Jian; Deng, Yansha; Wang, Xingwei; Aghvami, Abdol-Hamid

    2017-10-09

    The development of wireless power transfer (WPT) technology has inspired the transition from traditional battery-based wireless sensor networks (WSNs) towards wireless rechargeable sensor networks (WRSNs). While extensive efforts have been made to improve charging efficiency, little has been done for routing optimization. In this work, we present a joint optimization model to maximize both charging efficiency and routing structure. By analyzing the structure of the optimization model, we first decompose the problem and propose a heuristic algorithm to find the optimal charging efficiency for the predefined routing tree. Furthermore, by coding the many-to-one communication topology as an individual, we further propose to apply a genetic algorithm (GA) for the joint optimization of both routing and charging. The genetic operations, including tree-based recombination and mutation, are proposed to obtain a fast convergence. Our simulation results show that the heuristic algorithm reduces the number of resident locations and the total moving distance. We also show that our proposed algorithm achieves a higher charging efficiency compared with existing algorithms.

  5. Deterministic Joint Remote Preparation of an Arbitrary Sevenqubit Cluster-type State

    NASA Astrophysics Data System (ADS)

    Ding, MengXiao; Jiang, Min

    2017-06-01

    In this paper, we propose a scheme for joint remotely preparing an arbitrary seven-qubit cluster-type state by using several GHZ entangled states as the quantum channel. The coefficients of the prepared states can be not only real, but also complex. Firstly, Alice performs a three-qubit projective measurement according to the amplitude coefficients of the target state, and then Bob carries out another three-qubit projective measurement based on its phase coefficients. Next, one three-qubit state containing all information of the target state is prepared with suitable operation. Finally, the target seven-qubit cluster-type state can be prepared by introducing four auxiliary qubits and performing appropriate local unitary operations based on the prepared three-qubit state in a deterministic way. The receiver's all recovery operations are summarized into a concise formula. Furthermore, it's worth noting that our scheme is more novel and feasible with the present technologies than most other previous schemes.

  6. Joint Chiefs of Staff > Directorates > J1 | Manpower and Personnel

    Science.gov Websites

    Management J1 | Manpower and Personnel J2 | Joint Staff Intelligence J3 | Operations J4 | Logistics► J8 | Force Structure, Resources & Assessment Contact J1 Manpower and Personnel Home : Directorates : J1 | Manpower and Personnel Mission To provide the Chairman of the Joint Chiefs of Staff

  7. Efficient operator splitting algorithm for joint sparsity-regularized SPIRiT-based parallel MR imaging reconstruction.

    PubMed

    Duan, Jizhong; Liu, Yu; Jing, Peiguang

    2018-02-01

    Self-consistent parallel imaging (SPIRiT) is an auto-calibrating model for the reconstruction of parallel magnetic resonance imaging, which can be formulated as a regularized SPIRiT problem. The Projection Over Convex Sets (POCS) method was used to solve the formulated regularized SPIRiT problem. However, the quality of the reconstructed image still needs to be improved. Though methods such as NonLinear Conjugate Gradients (NLCG) can achieve higher spatial resolution, these methods always demand very complex computation and converge slowly. In this paper, we propose a new algorithm to solve the formulated Cartesian SPIRiT problem with the JTV and JL1 regularization terms. The proposed algorithm uses the operator splitting (OS) technique to decompose the problem into a gradient problem and a denoising problem with two regularization terms, which is solved by our proposed split Bregman based denoising algorithm, and adopts the Barzilai and Borwein method to update step size. Simulation experiments on two in vivo data sets demonstrate that the proposed algorithm is 1.3 times faster than ADMM for datasets with 8 channels. Especially, our proposal is 2 times faster than ADMM for the dataset with 32 channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Space Suit Joint Torque Measurement Method Validation

    NASA Technical Reports Server (NTRS)

    Valish, Dana; Eversley, Karina

    2012-01-01

    In 2009 and early 2010, a test method was developed and performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits. This was done in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design met the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future development programs. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis; the results indicated a significant variance in values reported for a subset of the re-tested joints. Potential variables that could have affected the data were identified and a third round of testing was conducted in an attempt to eliminate and/or quantify the effects of these variables. The results of the third test effort will be used to determine whether or not the proposed joint torque methodology can be applied to future space suit development contracts.

  9. Estimation of Finger Joint Angles Based on Electromechanical Sensing of Wrist Shape.

    PubMed

    Kawaguchi, Junki; Yoshimoto, Shunsuke; Kuroda, Yoshihiro; Oshiro, Osamu

    2017-09-01

    An approach to finger motion capture that places fewer restrictions on the usage environment and actions of the user is an important research topic in biomechanics and human-computer interaction. We proposed a system that electrically detects finger motion from the associated deformation of the wrist and estimates the finger joint angles using multiple regression models. A wrist-mounted sensing device with 16 electrodes detects deformation of the wrist from changes in electrical contact resistance at the skin. In this study, we experimentally investigated the accuracy of finger joint angle estimation, the adequacy of two multiple regression models, and the resolution of the estimation of total finger joint angles. In experiments, both the finger joint angles and the system output voltage were recorded as subjects performed flexion/extension of the fingers. These data were used for calibration using the least-squares method. The system was found to be capable of estimating the total finger joint angle with a root-mean-square error of 29-34 degrees. A multiple regression model with a second-order polynomial basis function was shown to be suitable for the estimation of all total finger joint angles, but not those of the thumb.

  10. Seismic Strengthening of Carpentry Joints in Traditional Timber Structures

    NASA Astrophysics Data System (ADS)

    Parisi, Maria A.; Cordié, Cinzia; Piazza, Maurizio

    2008-07-01

    The static and dynamic behavior of timber structures largely depends on their connections. In traditional timber construction, elements are usually connected with carpentry joints based on contact pressure and friction, often with only minor reinforcement generically intended to avoid disassembling. In current practice, interventions for the upgrading of carpentry joints are mainly based on empirical knowledge according to tradition. Often they produce a general strengthening of the connection, but are not specific for the case of seismic action. Strengthening on heuristic bases may be only partially effective or possibly disproportioned. The behavior of the carpentry joints most used in roof structures is examined. The birdsmouth joint, connecting rafters to the tie beam, has been studied first, characterizing its behavior numerically and experimentally in monotonic and cyclic conditions. Other forms of the rafter-to-tie connection, the double notch joint and the case of parallel rafters, are discussed. Some general criteria for the seismic strengthening of these joints are presented.

  11. Fusimotor control of spindle sensitivity regulates central and peripheral coding of joint angles.

    PubMed

    Lan, Ning; He, Xin

    2012-01-01

    Proprioceptive afferents from muscle spindles encode information about peripheral joint movements for the central nervous system (CNS). The sensitivity of muscle spindle is nonlinearly dependent on the activation of gamma (γ) motoneurons in the spinal cord that receives inputs from the motor cortex. How fusimotor control of spindle sensitivity affects proprioceptive coding of joint position is not clear. Furthermore, what information is carried in the fusimotor signal from the motor cortex to the muscle spindle is largely unknown. In this study, we addressed the issue of communication between the central and peripheral sensorimotor systems using a computational approach based on the virtual arm (VA) model. In simulation experiments within the operational range of joint movements, the gamma static commands (γ(s)) to the spindles of both mono-articular and bi-articular muscles were hypothesized (1) to remain constant, (2) to be modulated with joint angles linearly, and (3) to be modulated with joint angles nonlinearly. Simulation results revealed a nonlinear landscape of Ia afferent with respect to both γ(s) activation and joint angle. Among the three hypotheses, the constant and linear strategies did not yield Ia responses that matched the experimental data, and therefore, were rejected as plausible strategies of spindle sensitivity control. However, if γ(s) commands were quadratically modulated with joint angles, a robust linear relation between Ia afferents and joint angles could be obtained in both mono-articular and bi-articular muscles. With the quadratic strategy of spindle sensitivity control, γ(s) commands may serve as the CNS outputs that inform the periphery of central coding of joint angles. The results suggest that the information of joint angles may be communicated between the CNS and muscles via the descending γ(s) efferent and Ia afferent signals.

  12. Microstructure and Mechanical Properties of Laser Welded Joints of DZ125L and IN718 Nickel Base Superalloys

    NASA Astrophysics Data System (ADS)

    Liang, Taosha; Wang, Lei; Liu, Yang; Song, Xiu

    2018-05-01

    The microstructure and mechanical properties of the laser welded joint of DZ125L and IN718 nickel base superalloys were investigated. The results show that the fusion zone (FZ) mainly consists of fine dendrite structure with fine γ', Laves phases and MC carbides inhomogeneously distributed. The high welding temperature induces the partial dissolution of γ' in the heat-affected zone (HAZ) of DZ125L and liquation of grain boundaries in both of the HAZs. After post-weld heat treatment (PWHT), fine γ″ and γ' phases precipitate in the FZ, IN718 HAZ and IN718 base metal (BM), and fine γ' precipitate in the γ channel of the HAZ and BM of DZ125L. With tensile testing, the joints after PWHT show higher strengths than that of the weaker DZ125L alloy. Plastic deformation mainly concentrates in the weaker DZ125L and the joint finally fails in the DZ125L BM.

  13. Application of three-dimensional rendering in joint-related ganglion cysts.

    PubMed

    Spinner, Robert J; Edwards, Phillip K; Amrami, Kimberly K

    2006-05-01

    The origin of para-articular cysts is poorly understood and controversial. The relatively common, simple (extraneural) cysts are presumed to be derived from joints, although joint connections are not always established. Rarer complex cysts are thought by many to form de novo within nerves (intraneural ganglion cysts) or within vessels (adventitial cysts) (degenerative theory). We believe that these simple and complex ganglion cysts are joint-related (articular theory). Joint connections are often not readily appreciated with routine imaging or at surgery. Not identifying and/or treating joint connections frequently leads to cyst recurrence. More sophisticated imaging may enhance visualization of these joint connections. We created a 3D rendering technique to assess potential joint connections of simple and complex cysts localized to the knee and superior tibiofibular joints in patients with fibular (peroneal) neuropathy. Two- and three-dimensional data sets from MRI examinations were segmented semiautomatically by signal intensity with further refinement based on interaction with the user to identify specific anatomic structures, such as small nerves and vessels on serial images. The bone, cysts, nerves, and vessels were each assigned different color representations, and 3D renderings were created in ANALYZE using the data sets closest to isotropic (voxel with equal length in all dimensions) resolution as the primary background rendering. We selected four cases to illustrate the spectrum of pathology. In all of these cases, we demonstrated joint connections and correlated imaging and operative findings. Surgery addressing the cyst and the joint connection resulted in excellent outcomes; postoperative MRIs done more than 6 months later confirmed that there was no recurrence. In addition to highlighting the important relationship of these cysts to neighboring anatomic structures, this 3D technique allows visualization of "occult" connections not readily appreciated

  14. Gemini base facility operations environmental monitoring: key systems and tools for the remote operator

    NASA Astrophysics Data System (ADS)

    Cordova, Martin; Serio, Andrew; Meza, Francisco; Arriagada, Gustavo; Swett, Hector; Ball, Jesse; Collins, Paul; Masuda, Neal; Fuentes, Javier

    2016-07-01

    In 2014 Gemini Observatory started the base facility operations (BFO) project. The project's goal was to provide the ability to operate the two Gemini telescopes from their base facilities (respectively Hilo, HI at Gemini North, and La Serena, Chile at Gemini South). BFO was identified as a key project for Gemini's transition program, as it created an opportunity to reduce operational costs. In November 2015, the Gemini North telescope started operating from the base facility in Hilo, Hawaii. In order to provide the remote operator the tools to work from the base, many of the activities that were normally performed by the night staff at the summit were replaced with new systems and tools. This paper describes some of the key systems and tools implemented for environmental monitoring, and the design used in the implementation at the Gemini North telescope.

  15. The effect of local anaesthetic wound infiltration on chronic pain after lower limb joint replacement: A protocol for a double-blind randomised controlled trial

    PubMed Central

    2011-01-01

    Background For the majority of patients with osteoarthritis (OA), joint replacement is a successful intervention for relieving chronic joint pain. However, between 10-30% of patients continue to experience chronic pain after joint replacement. Evidence suggests that a risk factor for chronic pain after joint replacement is the severity of acute post-operative pain. The aim of this randomised controlled trial (RCT) is to determine if intra-operative local anaesthethic wound infiltration additional to a standard anaethesia regimen can reduce the severity of joint pain at 12-months after total knee replacement (TKR) and total hip replacement (THR) for OA. Methods 300 TKR patients and 300 THR patients are being recruited into this single-centre double-blind RCT. Participants are recruited before surgery and randomised to either the standard care group or the intervention group. Participants and outcome assessors are blind to treatment allocation throughout the study. The intervention consists of an intra-operative local anaesthetic wound infiltration, consisting of 60 mls of 0.25% bupivacaine with 1 in 200,000 adrenaline. Participants are assessed on the first 5 days post-operative, and then at 3-months, 6-months and 12-months. The primary outcome is the WOMAC Pain Scale, a validated measure of joint pain at 12-months. Secondary outcomes include pain severity during the in-patient stay, post-operative nausea and vomiting, satisfaction with pain relief, length of hospital stay, joint pain and disability, pain sensitivity, complications and cost-effectiveness. A nested qualitative study within the RCT will examine the acceptability and feasibility of the intervention for both patients and healthcare professionals. Discussion Large-scale RCTs assessing the effectiveness of a surgical intervention are uncommon, particulary in orthopaedics. The results from this trial will inform evidence-based recommendations for both short-term and long-term pain management after lower

  16. Joint sparsity based heterogeneous data-level fusion for target detection and estimation

    NASA Astrophysics Data System (ADS)

    Niu, Ruixin; Zulch, Peter; Distasio, Marcello; Blasch, Erik; Shen, Dan; Chen, Genshe

    2017-05-01

    Typical surveillance systems employ decision- or feature-level fusion approaches to integrate heterogeneous sensor data, which are sub-optimal and incur information loss. In this paper, we investigate data-level heterogeneous sensor fusion. Since the sensors monitor the common targets of interest, whose states can be determined by only a few parameters, it is reasonable to assume that the measurement domain has a low intrinsic dimensionality. For heterogeneous sensor data, we develop a joint-sparse data-level fusion (JSDLF) approach based on the emerging joint sparse signal recovery techniques by discretizing the target state space. This approach is applied to fuse signals from multiple distributed radio frequency (RF) signal sensors and a video camera for joint target detection and state estimation. The JSDLF approach is data-driven and requires minimum prior information, since there is no need to know the time-varying RF signal amplitudes, or the image intensity of the targets. It can handle non-linearity in the sensor data due to state space discretization and the use of frequency/pixel selection matrices. Furthermore, for a multi-target case with J targets, the JSDLF approach only requires discretization in a single-target state space, instead of discretization in a J-target state space, as in the case of the generalized likelihood ratio test (GLRT) or the maximum likelihood estimator (MLE). Numerical examples are provided to demonstrate that the proposed JSDLF approach achieves excellent performance with near real-time accurate target position and velocity estimates.

  17. 49 CFR 1562.25 - Fixed base operator requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 9 2011-10-01 2011-10-01 false Fixed base operator requirements. 1562.25 Section 1562.25 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY... Operations § 1562.25 Fixed base operator requirements. (a) Security program. Each FBO must adopt and carry...

  18. 49 CFR 1562.25 - Fixed base operator requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 9 2013-10-01 2013-10-01 false Fixed base operator requirements. 1562.25 Section 1562.25 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY... Operations § 1562.25 Fixed base operator requirements. (a) Security program. Each FBO must adopt and carry...

  19. 49 CFR 1562.25 - Fixed base operator requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 9 2012-10-01 2012-10-01 false Fixed base operator requirements. 1562.25 Section 1562.25 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY... Operations § 1562.25 Fixed base operator requirements. (a) Security program. Each FBO must adopt and carry...

  20. 49 CFR 1562.25 - Fixed base operator requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Fixed base operator requirements. 1562.25 Section 1562.25 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY... Operations § 1562.25 Fixed base operator requirements. (a) Security program. Each FBO must adopt and carry...

  1. Passive Capture Joint with Three Degrees of Freedom

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Weddendorf, Bruce (Inventor)

    2001-01-01

    A passive capture joint with three degrees of freedom is presented wherein two structural elements are joined together solely by moving the two elements into position, and which when joined together have rotation in all three axes. The inventive apparatus is comprised of two halves: (1) a joint ball mounted on a stem as in a common trailer hitch, and; (2) a socket. The socket consists of a base having an exterior wall and forming an interior chamber, the chamber having a top end and a bottom end, and an interior wall. The chamber is open at the top end, and forms a spherical cup at the bottom end. The socket base's interior chamber is sized to accept the joint ball. The base also forms at least one bore at an acute angle away from the interior chamber's open end. The bores have a first opening in the interior wall of the chamber, and a second opening in the exterior wall of the base. Retaining balls sized to fit within the bores, but to only partially pass through the first opening, are moveably housed within the bores. The retaining balls are moveably held in the first opening by a compression spring housed in the bore. As the joint ball is inserted in the chamber it forces the retaining balls back into the bore until the equator of the joint ball passes. Because the bore is at an acute angle to the chamber the joint ball cannot exit the chamber without the joint being unlocked. The joint is unlocked by rotating a locking ring which encircles the base and covers the second opening. The locking ring has a radial slot for each retaining ball, disposed angularly from the base, and sized to allow passage of the retaining ball in the radial direction when the locking ring is rotated to align the radial slot with the second opening.

  2. A video coding scheme based on joint spatiotemporal and adaptive prediction.

    PubMed

    Jiang, Wenfei; Latecki, Longin Jan; Liu, Wenyu; Liang, Hui; Gorman, Ken

    2009-05-01

    We propose a video coding scheme that departs from traditional Motion Estimation/DCT frameworks and instead uses Karhunen-Loeve Transform (KLT)/Joint Spatiotemporal Prediction framework. In particular, a novel approach that performs joint spatial and temporal prediction simultaneously is introduced. It bypasses the complex H.26x interframe techniques and it is less computationally intensive. Because of the advantage of the effective joint prediction and the image-dependent color space transformation (KLT), the proposed approach is demonstrated experimentally to consistently lead to improved video quality, and in many cases to better compression rates and improved computational speed.

  3. Influence of a perturbation in the Gyrator domain for a joint transform correlator-based encryption system

    NASA Astrophysics Data System (ADS)

    Vilardy, Juan M.; Millán, María. S.; Pérez-Cabré, Elisabet

    2017-08-01

    We present the results of the noise and occlusion tests in the Gyrator domain (GD) for a joint transform correlator-based encryption system. This encryption system was recently proposed and it was implemented by using a fully phase nonzero-order joint transform correlator (JTC) and the Gyrator transform (GT). The decryption system was based on two successive GTs. In this paper, we make several numerical simulations in order to test the performance and robustness of the JTC-based encryption-decryption system in the GD when the encrypted image is corrupted by noise or occlusion. The encrypted image is affected by additive and multiplicative noise. We also test the effect of data loss due to partial occlusion of the encrypted information. Finally, we evaluate the performance and robustness of the encryption-decryption system in the GD by using the metric of the root mean square error (RMSE) between the original image and the decrypted image when the encrypted image is degraded by noise or modified by occlusion.

  4. CONICAL, RADIOGRAPHIC, AND PATIENT-REPORTED RESULTS OF SURFACE REPLACING PROXIMAL INTERPHALANGEAL JOINT ARTHROPLASTY OF THE HAND

    PubMed Central

    Amirtharajah, Mohana; Fufa, Duretti; Lightdale, Nina; Weiland, Andew

    2011-01-01

    The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant PMID:22096433

  5. RIMPAC 08: Naval Oceanographic Office glider operations

    NASA Astrophysics Data System (ADS)

    Mahoney, Kevin L.; Grembowicz, Ken; Bricker, Bruce; Crossland, Steve; Bryant, Danielle; Torres, Marc; Giddings, Tom

    2009-05-01

    The Naval Oceanographic Office (NAVOCEANO) Glider Operations Center (GOC) supported its first joint-mission exercise during Rim of the Pacific (RIMPAC) 08, a multi-national naval exercise conducted during July 2008 near the Hawaiian Islands. NAVOCEANO personnel deployed four Seagliders from USNS SUMNER for Anti-submarine Warfare (ASW) operations and four Slocum gliders for Mine Warfare (MIW) operations. Each Seaglider was equipped with a Sea-Bird Electronics (SBE) 41cp CTD and Wet Labs, Inc. bb2fl ECO-puck optical sensor. The instrumentation suite on the Slocum gliders varied, but each Slocum glider had an SBE 41cp CTD combined with one of the following optical sensors: a Wet Labs, Inc. AUVb scattering sensor, a Wet Labs, Inc. bb3slo ECO-puck backscattering sensor, or a Satlantic, Inc. OCR radiometer. Using Iridium communications, the GOC had command and control of all eight gliders, with Department of Defense (DoD) personnel and DoD contractors serving as glider pilots. Raw glider data were transmitted each time a glider surfaced, and the subsequent data flow included processing, quality-control procedures, and the generation of operational and tactical products. The raw glider data were also sent to the Naval Research Laboratory at Stennis Space Center (NRLSSC) for fusion with satellite data and modeled data (currents, tides, etc.) to create optical forecasting, optical volume, and electro-optical identification (EOID) performance surface products. The glider-based products were delivered to the ASW and MIW Reach Back Cells for incorporation into METOC products and for dissemination to the Fleet. Based on the metrics presented in this paper, the inaugural joint-mission operation was a success.

  6. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    NASA Astrophysics Data System (ADS)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  7. Joint Chiefs of Staff > Directorates > J6 | C4 & Cyber

    Science.gov Websites

    the Joint Staff Chief Information Officer (CIO), the J-6 provides business class Information on Facebook on Flickr Joint Chiefs► Army Chief of Staff Marine Corps Commandant Chief of Naval Operations Air Force Chief of Staff Chief of National Guard Bureau Biographies Directorates Directorates of

  8. The Development of Action Planning in a Joint Action Context

    ERIC Educational Resources Information Center

    Paulus, Markus

    2016-01-01

    The ability to act jointly with another person is a fundamental requirement for participation in social life. The current study examines the development of action planning in a joint action context. In 4 experiments, 3-, 5-, and 7-year-old children as well as a group of adults (n = 196) interacted with another person to operate a novel apparatus.…

  9. Treatment of first metatarsophalangeal joint arthritis using hemiarthroplasty with a synthetic cartilage implant or arthrodesis: A comparison of operative and recovery time.

    PubMed

    Glazebrook, Mark; Younger, Alastair S E; Daniels, Timothy R; Singh, Dishan; Blundell, Chris; de Vries, Gwyneth; Le, Ian L D; Nielsen, Dominic; Pedersen, M Elizabeth; Sakellariou, Anthony; Solan, Matthew; Wansbrough, Guy; Baumhauer, Judith F

    2017-05-29

    First metatarsophalangeal joint (MTPJ1) hemiarthroplasty using a novel synthetic cartilage implant was as effective and safe as MTPJ1 arthrodesis in a randomized clinical trial. We retrospectively evaluated operative time and recovery period for implant hemiarthroplasty (n=152) and MTPJ1 arthrodesis (n=50). Perioperative data were assessed for operative and anaesthesia times. Recovery and return to function were prospectively assessed with the Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) subscales and SF-36 Physical Functioning (PF) subscore. Mean operative time for hemiarthroplasty was 35±12.3min and 58±21.5min for arthrodesis (p<0.001). Anaesthesia duration was 28min shorter with hemiarthroplasty (p<0.001). At weeks 2 and 6 postoperative, hemiarthroplasty patients demonstrated clinically and statistically significantly higher FAAM Sport, FAAM ADL, and SF-36 PF subscores versus arthrodesis patients. MTPJ1 hemiarthroplasty with a synthetic cartilage implant took less operative time and resulted in faster recovery than arthrodesis. III, Retrospective case control study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  10. Clinical outcomes of the Cadenat procedure in the treatment of acromioclavicular joint dislocations.

    PubMed

    Moriyama, Hiroaki; Gotoh, Masafumi; Mitsui, Yasuhiro; Yoshikawa, Eiichirou; Uryu, Takuya; Okawa, Takahiro; Higuchi, Fujio; Shirahama, Masahiro; Shiba, Naoto

    2014-01-01

    We report our clinical experience using the modified Cadenat method to treat acromioclavicular joint dislocation, and discuss the usefulness of this method. This study examined 6 shoulders in 6 patients (5 males, 1 female) who were diagnosed with acromioclavicular joint dislocation and treated with the modified Cadenat method at our hospital. Average age at onset was 49.3 years (26-78 years), average time interval from injury until surgery was 263.8 days (10 to 1100 days), and the average follow-up period was 21.7 months (12 to 42 months). Post-operative assessment was performed using plain radiographs to determine shoulder joint dislocation rate and Japanese Orthopaedic Association (JOA) score. The average post-operative JOA score was 94.1 points (91 to 100 points). The acromioclavicular joint dislocation rate improved from 148.7% (72 to 236%) before surgery to 28.6% (0 to 60%) after surgery. Conservative treatment has been reported to achieve good outcomes in acromioclavicular joint dislocations. However, many patients also experience chronic pain or a sensation of fatigue upon putting the extremity in an elevated posture, and therefore ensuring the stability of the acromioclavicular joint is crucial for highly active patients. In this study, we treated acromioclavicular joint dislocations by the modified Cadenat method, and were able to achieve favorable outcomes.

  11. The quantitative role of flexor sheath incision in correcting Dupuytren proximal interphalangeal joint contractures.

    PubMed

    Blazar, P E; Floyd, E W; Earp, B E

    2016-07-01

    Controversy exists regarding intra-operative treatment of residual proximal interphalangeal joint contractures after Dupuytren's fasciectomy. We test the hypothesis that a simple release of the digital flexor sheath can correct residual fixed flexion contracture after subtotal fasciectomy. We prospectively enrolled 19 patients (22 digits) with Dupuytren's contracture of the proximal interphalangeal joint. The average pre-operative extension deficit of the proximal interphalangeal joints was 58° (range 30-90). The flexion contracture of the joint was corrected to an average of 28° after fasciectomy. In most digits (20 of 21), subsequent incision of the flexor sheath further corrected the contracture by an average of 23°, resulting in correction to an average flexion contracture of 4.7° (range 0-40). Our results support that contracture of the tendon sheath is a contributor to Dupuytren's contracture of the joint and that sheath release is a simple, low morbidity addition to correct Dupuytren's contractures of the proximal interphalangeal joint. Additional release of the proximal interphalangeal joint after fasciectomy, after release of the flexor sheath, is not necessary in many patients. IV (Case Series, Therapeutic). © The Author(s) 2015.

  12. Adhesive Bonding Characterization of Composite Joints for Cryogenic Usage

    NASA Technical Reports Server (NTRS)

    Graf, Neil A.; Schieleit, Gregory F.; Biggs, Robert

    2000-01-01

    The development of polymer composite cryogenic tanks is a critical step in creating the next generation of launch vehicles. Future reusable launch vehicles need to minimize the gross liftoff weight (GLOW). This weight reduction is possible due to the large reduction in weight that composite materials can provide over current aluminum technology. In addition to composite technology, adhesively bonded joints potentially have several benefits over mechanically fastened joints, such as weight savings and cryogenic fluid containment. Adhesively bonded joints may be used in several areas of these cryogenic tanks, such as in lobe-to-lobe joints (in a multi-lobe concept), skirt-to-tank joint, strut-to-tank joint, and for attaching stringers and ring frames. The bonds, and the tanks themselves, must be able to withstand liquid cryogenic fuel temperatures that they contain. However, the use of adhesively bonded composite joints at liquid oxygen and hydrogen temperatures is largely unknown and must be characterized. Lockheed Martin Space Systems Company, Michoud Operations performed coupon-level tests to determine effects of material selection, cure process parameters, substrate surface preparation, and other factors on the strength of these composite joints at cryogenic temperatures. This led to the selection of a material and process that would be suitable for a cryogenic tank. KEY WORDS: Composites, Adhesive Bonding, Cryogenics

  13. The Disestablishment of U.S. Joint Forces Command: A Step Backward in Jointness

    DTIC Science & Technology

    2011-06-01

    and the less than stellar 1983 rescue of a few medical students from the island of Grenada (Operation Urgent Fury), Congress passed the Goldwater...an opportunity for dialogue and a source of basic joint doctrine, it was widely ignored despite increasing tension and preparation for the Second... basic unity of effort appeared lacking even with dialogue like the Key West Agreements. Dr. William Niskanen, with the CATO Institute, described the

  14. Acute Ankle Sprain in a Mouse Model: Changes in Knee-Joint Space.

    PubMed

    Hubbard-Turner, Tricia; Wikstrom, Erik A; Guderian, Sophie; Turner, Michael J

    2017-06-02

      Ankle sprains remain the most common orthopaedic injury. Conducting long-term studies in humans is difficult and costly, so the long-term consequences of an ankle sprain are not entirely known.   To measure knee-joint space after a single surgically induced ankle sprain in mice.   Randomized controlled trial.   University research laboratory.   Thirty male mice (CBA/2J) were randomly placed into 1 of 3 surgical groups: the transected calcaneofibular ligament (CFL) group, the transected anterior talofibular ligament/CFL group, or a sham treatment group. The right ankle was operated on in all mice.   Three days after surgery, all of the mice were individually housed in cages containing a solid-surface running wheel, and daily running-wheel measurements were recorded. Before surgery and every 6 weeks after surgery, a diagnostic ultrasound was used to measure medial and lateral knee-joint space in both hind limbs.   Right medial (P = .003), right lateral (P = .002), left medial (P = .03), and left lateral (P = .002) knee-joint spaces decreased across the life span. The mice in the anterior talofibular ligament/CFL group had decreased right medial (P = .004) joint space compared with the sham and CFL groups starting at 24 weeks of age and continuing throughout the life span. No differences occurred in contralateral knee-joint degeneration among any of the groups.   Based on current data, mice that sustained a surgically induced severe ankle sprain developed greater joint degeneration in the ipsilateral knee. Knee degeneration could result from accommodation to the laxity of the ankle or biomechanical alterations secondary to ankle instability. A single surgically induced ankle sprain could significantly affect knee-joint function.

  15. Forces associated with pneumatic power screwdriver operation: statics and dynamics.

    PubMed

    Lin, Jia-Hua; Radwin, Robert G; Fronczak, Frank J; Richard, Terry G

    2003-10-10

    The statics and dynamics of pneumatic power screwdriver operation were investigated in the context of predicting forces acting against the human operator. A static force model is described in the paper, based on tool geometry, mass, orientation in space, feed force, torque build up, and stall torque. Three common power hand tool shapes are considered, including pistol grip, right angle, and in-line. The static model estimates handle force needed to support a power nutrunner when it acts against the tightened fastener with a constant torque. A system of equations for static force and moment equilibrium conditions are established, and the resultant handle force (resolved in orthogonal directions) is calculated in matrix form. A dynamic model is formulated to describe pneumatic motor torque build-up characteristics dependent on threaded fastener joint hardness. Six pneumatic tools were tested to validate the deterministic model. The average torque prediction error was 6.6% (SD = 5.4%) and the average handle force prediction error was 6.7% (SD = 6.4%) for a medium-soft threaded fastener joint. The average torque prediction error was 5.2% (SD = 5.3%) and the average handle force prediction error was 3.6% (SD = 3.2%) for a hard threaded fastener joint. Use of these equations for estimating handle forces based on passive mechanical elements representing the human operator is also described. These models together should be useful for considering tool handle force in the selection and design of power screwdrivers, particularly for minimizing handle forces in the prevention of injuries and work related musculoskeletal disorders.

  16. 2007 Joint Chemical Biological, Radiological and Nuclear (CBRN) Conference and Exhibition - Combating Weapons of Mass Destruction

    DTIC Science & Technology

    2007-06-27

    Selected CB Defense Systems SHAPESENSE Joint Warning and Reporting Network JSLIST CB Protected Shelter Joint Vaccine Acquisition Program Joint Effects...military can operate in any environment, unconstrained by chemical or biological weapons. 21 SHIELD SUSTAIN Selected CB Defense Systems SHAPESENSE Joint...28070625_JCBRN_Conference_Reeves UNCLASSIFIED Decontamination Vision Strippable Barriers Self-Decontaminating Fabrics/Coatings Reduce Logistics Burden

  17. Cupola windows during Joint Operations

    NASA Image and Video Library

    2010-02-17

    ISS022-E-066963 (17 Feb. 2010) --- This image is among the first taken through a first of its kind ?bay window? on the International Space Station, the seven-windowed Cupola. The image shows the coast of Algeria featuring (in the Cupola?s round window) an area between the cities of Dellys and Algiers. The image was recorded with a digital still camera using a 28mm lens setting. The Cupola, which a week and half ago was brought up to the orbital outpost by the STS-130 crew on the space shuttle Endeavour, will house controls for the station robotics and will be a location where crew members can operate the robotic arms and monitor other exterior activities.

  18. A joint sparse representation-based method for double-trial evoked potentials estimation.

    PubMed

    Yu, Nannan; Liu, Haikuan; Wang, Xiaoyan; Lu, Hanbing

    2013-12-01

    In this paper, we present a novel approach to solving an evoked potentials estimating problem. Generally, the evoked potentials in two consecutive trials obtained by repeated identical stimuli of the nerves are extremely similar. In order to trace evoked potentials, we propose a joint sparse representation-based double-trial evoked potentials estimation method, taking full advantage of this similarity. The estimation process is performed in three stages: first, according to the similarity of evoked potentials and the randomness of a spontaneous electroencephalogram, the two consecutive observations of evoked potentials are considered as superpositions of the common component and the unique components; second, making use of their characteristics, the two sparse dictionaries are constructed; and finally, we apply the joint sparse representation method in order to extract the common component of double-trial observations, instead of the evoked potential in each trial. A series of experiments carried out on simulated and human test responses confirmed the superior performance of our method. © 2013 Elsevier Ltd. Published by Elsevier Ltd. All rights reserved.

  19. Cadaveric and in vivo human joint imaging based on differential phase contrast by X-ray Talbot-Lau interferometry.

    PubMed

    Tanaka, Junji; Nagashima, Masabumi; Kido, Kazuhiro; Hoshino, Yoshihide; Kiyohara, Junko; Makifuchi, Chiho; Nishino, Satoshi; Nagatsuka, Sumiya; Momose, Atsushi

    2013-09-01

    We developed an X-ray phase imaging system based on Talbot-Lau interferometry and studied its feasibility for clinical diagnoses of joint diseases. The system consists of three X-ray gratings, a conventional X-ray tube, an object holder, an X-ray image sensor, and a computer for image processing. The joints of human cadavers and healthy volunteers were imaged, and the results indicated sufficient sensitivity to cartilage, suggesting medical significance. Copyright © 2012. Published by Elsevier GmbH.

  20. Angioplasty balloon catheters used for distraction of the ankle joint.

    PubMed

    Sartoretti, C; Sartoretti-Schefer, S; Duff, C; Buchmann, P

    1996-02-01

    Arthroscopy of the ankle joint is now routinely performed in diagnostic and therapeutic interventions but is still a demanding and difficult operative procedure in this very small and tight joint. Arthroscopy can be facilitated by a sufficient distraction that gives a better overview of the joint space. However, it is still a matter of debate how to obtain the adequate distraction. Distention by manual strength as well as by the help of a technical device have been proposed. We report our experience with distraction of the ankle joint by the help of one or two intraarticularily located and secondarily insufflated angioplasty balloon catheters that are routinely used in interventional radiology. These special catheters allow a careful and controlled distention of the joint with a fixed space of distraction and, according to our limited experience, without any morbidity.

  1. Joint-layer encoder optimization for HEVC scalable extensions

    NASA Astrophysics Data System (ADS)

    Tsai, Chia-Ming; He, Yuwen; Dong, Jie; Ye, Yan; Xiu, Xiaoyu; He, Yong

    2014-09-01

    Scalable video coding provides an efficient solution to support video playback on heterogeneous devices with various channel conditions in heterogeneous networks. SHVC is the latest scalable video coding standard based on the HEVC standard. To improve enhancement layer coding efficiency, inter-layer prediction including texture and motion information generated from the base layer is used for enhancement layer coding. However, the overall performance of the SHVC reference encoder is not fully optimized because rate-distortion optimization (RDO) processes in the base and enhancement layers are independently considered. It is difficult to directly extend the existing joint-layer optimization methods to SHVC due to the complicated coding tree block splitting decisions and in-loop filtering process (e.g., deblocking and sample adaptive offset (SAO) filtering) in HEVC. To solve those problems, a joint-layer optimization method is proposed by adjusting the quantization parameter (QP) to optimally allocate the bit resource between layers. Furthermore, to make more proper resource allocation, the proposed method also considers the viewing probability of base and enhancement layers according to packet loss rate. Based on the viewing probability, a novel joint-layer RD cost function is proposed for joint-layer RDO encoding. The QP values of those coding tree units (CTUs) belonging to lower layers referenced by higher layers are decreased accordingly, and the QP values of those remaining CTUs are increased to keep total bits unchanged. Finally the QP values with minimal joint-layer RD cost are selected to match the viewing probability. The proposed method was applied to the third temporal level (TL-3) pictures in the Random Access configuration. Simulation results demonstrate that the proposed joint-layer optimization method can improve coding performance by 1.3% for these TL-3 pictures compared to the SHVC reference encoder without joint-layer optimization.

  2. 25 CFR 142.8 - Is economy of operation a requirement for the Alaska Resupply Operation?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false Is economy of operation a requirement for the Alaska... FINANCIAL ACTIVITIES ALASKA RESUPPLY OPERATION § 142.8 Is economy of operation a requirement for the Alaska..., or cooperative arrangements. Whenever possible joint arrangements for economy will be entered into...

  3. 25 CFR 142.8 - Is economy of operation a requirement for the Alaska Resupply Operation?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false Is economy of operation a requirement for the Alaska... FINANCIAL ACTIVITIES ALASKA RESUPPLY OPERATION § 142.8 Is economy of operation a requirement for the Alaska..., or cooperative arrangements. Whenever possible joint arrangements for economy will be entered into...

  4. 25 CFR 142.8 - Is economy of operation a requirement for the Alaska Resupply Operation?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true Is economy of operation a requirement for the Alaska... FINANCIAL ACTIVITIES ALASKA RESUPPLY OPERATION § 142.8 Is economy of operation a requirement for the Alaska..., or cooperative arrangements. Whenever possible joint arrangements for economy will be entered into...

  5. 25 CFR 142.8 - Is economy of operation a requirement for the Alaska Resupply Operation?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false Is economy of operation a requirement for the Alaska... FINANCIAL ACTIVITIES ALASKA RESUPPLY OPERATION § 142.8 Is economy of operation a requirement for the Alaska..., or cooperative arrangements. Whenever possible joint arrangements for economy will be entered into...

  6. An equilibrium-point model of electromyographic patterns during single-joint movements based on experimentally reconstructed control signals.

    PubMed

    Latash, M L; Goodman, S R

    1994-01-01

    The purpose of this work has been to develop a model of electromyographic (EMG) patterns during single-joint movements based on a version of the equilibrium-point hypothesis, a method for experimental reconstruction of the joint compliant characteristics, the dual-strategy hypothesis, and a kinematic model of movement trajectory. EMG patterns are considered emergent properties of hypothetical control patterns that are equally affected by the control signals and peripheral feedback reflecting actual movement trajectory. A computer model generated the EMG patterns based on simulated movement kinematics and hypothetical control signals derived from the reconstructed joint compliant characteristics. The model predictions have been compared to published recordings of movement kinematics and EMG patterns in a variety of movement conditions, including movements over different distances, at different speeds, against different-known inertial loads, and in conditions of possible unexpected decrease in the inertial load. Changes in task parameters within the model led to simulated EMG patterns qualitatively similar to the experimentally recorded EMG patterns. The model's predictive power compares it favourably to the existing models of the EMG patterns. Copyright © 1994. Published by Elsevier Ltd.

  7. Joint Networking Command and Control (C2) Communications Among Distributed Operations, JCAS, and Joint Fires

    DTIC Science & Technology

    2007-06-01

    fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating Temperature: -22 to 160 °F, Operating Humidity Range: 5% to 100% Non...Accessories Double 90° tongue and groove case design, with anti-tamper fasteners. Enviromental Spec Storage Temperature: -26 to 160 °F, Operating

  8. How weak values emerge in joint measurements on cloned quantum systems.

    PubMed

    Hofmann, Holger F

    2012-07-13

    A statistical analysis of optimal universal cloning shows that it is possible to identify an ideal (but nonpositive) copying process that faithfully maps all properties of the original Hilbert space onto two separate quantum systems, resulting in perfect correlations for all observables. The joint probabilities for noncommuting measurements on separate clones then correspond to the real parts of the complex joint probabilities observed in weak measurements on a single system, where the measurements on the two clones replace the corresponding sequence of weak measurement and postselection. The imaginary parts of weak measurement statics can be obtained by replacing the cloning process with a partial swap operation. A controlled-swap operation combines both processes, making the complete weak measurement statistics accessible as a well-defined contribution to the joint probabilities of fully resolved projective measurements on the two output systems.

  9. Simplifying Bridge Expansion Joint Design and Maintenance

    DOT National Transportation Integrated Search

    2011-10-19

    This report presents a study focused on identifying the most durable expansion joints for the South : Carolina Department of Transportation. This is performed by proposing a degradation model for the : expansion joints and updating it based on bridge...

  10. Overview of Carbon Dioxide Control Issues During International Space Station/Space Shuttle Joint Docked Operations

    NASA Technical Reports Server (NTRS)

    Matty, Christopher M.

    2010-01-01

    Crewed space vehicles have a common requirement to remove the carbon dioxide (CO2) created by the metabolic processes of the crew. The space shuttle [Space Transportation System (STS)] and International Space Station (ISS) each have systems in place that allow control and removal of CO2 from the habitable cabin environment. During periods in which the space shuttle is docked to the ISS, known as "joint docked operations," the space shuttle and ISS share a common atmosphere environment. During this period, an elevated amount of CO2 is produced through the combined metabolic activity of the STS and ISS crews. This elevated CO2 production, together with the large effective atmosphere created by collective volumes of the docked vehicles, creates a unique set of requirements for CO2 removal. This paper will describe individual CO2 control plans implemented by STS and ISS engineering teams, as well as the integrated plans used when both vehicles are docked. The paper will also discuss some of the issues and anomalies experienced by both engineering teams.

  11. Overview of Carbon Dioxide Control Issues During International Space Station/Space Shuttle Joint Docked Operations

    NASA Technical Reports Server (NTRS)

    Matty, Christopher M.; Hayley, Elizabeth P.

    2009-01-01

    Manned space vehicles have a common requirement to remove the Carbon Dioxide (CO2) created by the metabolic processes of the crew. The Space Shuttle and International Space Station (ISS) each have systems in place to allow control and removal of CO2 from the habitable cabin environment. During periods where the Space Shuttle is docked to ISS, known as joint docked operations, the Space Shuttle and ISS share a common atmosphere environment. During this period there is an elevated production of CO2 caused by the combined metabolic activity of the Space Shuttle and ISS crew. This elevated CO2 production, combined with the large effective atmosphere created by the collective volumes of the docked vehicles, creates a unique set of requirements for CO2 removal. This paper will describe the individual CO2 control plans implemented by the Space Shuttle and ISS engineering teams, as well as the integrated plans used when both vehicles are docked. In addition, the paper will discuss some of the issues and anomalies experienced by both engineering teams.

  12. [Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].

    PubMed

    Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua

    2017-12-25

    To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.

  13. Talbot phase-contrast X-ray imaging for the small joints of the hand

    PubMed Central

    Stutman, Dan; Beck, Thomas J; Carrino, John A; Bingham, Clifton O

    2011-01-01

    A high resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of Rheumatoid Arthritis (RA) and Osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 μm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast or refraction based X-ray imaging (DPC) with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and it can be implemented with conventional X-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high resolution bench-top interferometer using 10 μm period gratings, a W anode tube and a CCD based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ~25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging comes thus mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ~2 m long ‘symmetric’ interferometer operated in a high Talbot order. PMID:21841214

  14. Talbot phase-contrast x-ray imaging for the small joints of the hand

    NASA Astrophysics Data System (ADS)

    Stutman, Dan; Beck, Thomas J.; Carrino, John A.; Bingham, Clifton O.

    2011-09-01

    A high-resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of rheumatoid arthritis (RA) and osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 µm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast (DPC) or refraction-based x-ray imaging with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and can be implemented with conventional x-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that, due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high-resolution bench-top interferometer using 10 µm period gratings, a W anode tube and a CCD-based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ~25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging thus comes mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ~2 m long 'symmetric' interferometer operated in a high Talbot order.

  15. Preparing for Operational Use of High Priority Products from the Joint Polar Satellite System (JPSS) in Numerical Weather Prediction

    NASA Astrophysics Data System (ADS)

    Nandi, S.; Layns, A. L.; Goldberg, M.; Gambacorta, A.; Ling, Y.; Collard, A.; Grumbine, R. W.; Sapper, J.; Ignatov, A.; Yoe, J. G.

    2017-12-01

    This work describes end to end operational implementation of high priority products from National Oceanic and Atmospheric Administration's (NOAA) operational polar-orbiting satellite constellation, to include Suomi National Polar-orbiting Partnership (S-NPP) and the Joint Polar Satellite System series initial satellite (JPSS-1), into numerical weather prediction and earth systems models. Development and evaluation needed for the initial implementations of VIIRS Environmental Data Records (EDR) for Sea Surface Temperature ingestion in the Real-Time Global Sea Surface Temperature Analysis (RTG) and Polar Winds assimilated in the National Weather Service (NWS) Global Forecast System (GFS) is presented. These implementations ensure continuity of data in these models in the event of loss of legacy sensor data. Also discussed is accelerated operational implementation of Advanced Technology Microwave Sounder (ATMS) Temperature Data Records (TDR) and Cross-track Infrared Sounder (CrIS) Sensor Data Records, identified as Key Performance Parameters by the National Weather Service. Operational use of SNPP after 28 October, 2011 launch took more than one year due to the learning curve and development needed for full exploitation of new remote sensing capabilities. Today, ATMS and CrIS data positively impact weather forecast accuracy. For NOAA's JPSS initial satellite (JPSS-1), scheduled for launch in late 2017, we identify scope and timelines for pre-launch and post-launch activities needed to efficiently transition these capabilities into operations. As part of these alignment efforts, operational readiness for KPPs will be possible as soon as 90 days after launch. The schedule acceleration is possible because of the experience with S-NPP. NOAA operational polar-orbiting satellite constellation provides continuity and enhancement of earth systems observations out to 2036. Program best practices and lessons learned will inform future implementation for follow-on JPSS-3 and -4

  16. Cyber Power for the Joint Force Commander: An Operational Design Framework

    DTIC Science & Technology

    2014-03-26

    William A. Owens, Kenneth W. Dam, and Herbert S. Lin, eds, Technology, Policy, Law, and Ethics Regarding U.S. Acquisition and Use of Cyberattack...and computer systems used in carrying out a mission.” 27 George J. Franz III, "Effective Synchronization and Integration of Effects Through...2007. Franz, George J. "Effective Synchronization and Integration of Effects Through Cyberspace for the Joint Warfighter." U.S. Cyber Command

  17. Canadian Forces in Joint Fires Support - Human Factors Analysis: Coalition Operations

    DTIC Science & Technology

    2010-08-01

    mesure/l’estimation des dommages collatéraux (EDC). Outil pour comprendre l’EDC de certains pays comparativement à celle des membres de l’OTAN et...Program (TDP). The TDP is aimed at concept development, evaluation for force design , and the demonstration of technologies fostered by Defence Research...logistics and the designation of targets on the joint targeting list. • Tactical capability / response time / training. The tactical capability of a fire

  18. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis.

    PubMed

    Bhuiyan, M S H; Choudhury, I A; Dahari, M; Nukman, Y; Dawal, S Z

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e-004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb.

  19. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis

    PubMed Central

    2017-01-01

    A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e−004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb. PMID:28584518

  20. Low-cost high-quality Fe-based shape memory alloys suitable for pipe joints

    NASA Astrophysics Data System (ADS)

    Kajiwara, Setsuo; Baruj, Albert L.; Kikuchi, Takehiko; Shinya, Norio

    2003-08-01

    By addition of small amount of Nb and C to the conventional Fe-Mn-Si based shape memory alloys, shape memory properties are greatly improved in such an extent that the costly 'training' heat treatment is no more necessary. The key to this remarkable improvement of shape memory effect is to produce small NbC precipitates of about several nm in size in austenite. In order to generate such very small NbC particles, the sample is firstly rolled at 870 K and then aged at 1070 K. An example of Fe-28Mn-6Si-5Cr-0.53Nb-0.06C (mass %) alloy is shown; 95% shape recovery for initial strain of 4% is obtained and the shape recovery stress of about 300 MPa is attained for the sample pre-rolled 14%, which is well above the criterion for industry application of pipe jointing. A pipe jointing with this material is demonstrated.

  1. Off-Grid Direction of Arrival Estimation Based on Joint Spatial Sparsity for Distributed Sparse Linear Arrays

    PubMed Central

    Liang, Yujie; Ying, Rendong; Lu, Zhenqi; Liu, Peilin

    2014-01-01

    In the design phase of sensor arrays during array signal processing, the estimation performance and system cost are largely determined by array aperture size. In this article, we address the problem of joint direction-of-arrival (DOA) estimation with distributed sparse linear arrays (SLAs) and propose an off-grid synchronous approach based on distributed compressed sensing to obtain larger array aperture. We focus on the complex source distribution in the practical applications and classify the sources into common and innovation parts according to whether a signal of source can impinge on all the SLAs or a specific one. For each SLA, we construct a corresponding virtual uniform linear array (ULA) to create the relationship of random linear map between the signals respectively observed by these two arrays. The signal ensembles including the common/innovation sources for different SLAs are abstracted as a joint spatial sparsity model. And we use the minimization of concatenated atomic norm via semidefinite programming to solve the problem of joint DOA estimation. Joint calculation of the signals observed by all the SLAs exploits their redundancy caused by the common sources and decreases the requirement of array size. The numerical results illustrate the advantages of the proposed approach. PMID:25420150

  2. The failure models of Sn-based solder joints under coupling effects of electromigration and thermal cycling

    NASA Astrophysics Data System (ADS)

    Ma, Limin; Zuo, Yong; Liu, Sihan; Guo, Fu; Wang, Xitao

    2013-01-01

    Currently, the main concerns of Pb-free solder joints are focusing on electromigration (EM) and thermomechanical fatigue (TMF) problems. Many models have been established to understand the failure mechanisms of the joint under such single test conditions. Based on the fact that almost all microelectronic devices serve in combination conditions of fluctuated temperature and electric current stressing, the coupling effects of EM and TMF on evolution of microstructure and resistance of solder joint had been investigated. The failure models of binary SnBi alloy and ternary SnAgCu (SAC) solder under the coupling stressing were divided into four and three different stages, respectively. The failure mechanisms were dominant by the relationship of phase segregation, polarity effect, phase coarsening, and the coefficient of thermal expansion mismatch. Cracks tend to form and propagate along the interface between intermetallic compound layers and solder matrix in SAC solder. However, grain boundary was considered as the nucleation sites for microcracks in SnBi solder. High current density alleviates the deterioration of solder at the beginning stage of coupling stressing through Joule heating effect. An abrupt jump of resistance could be observed before the failure of the joint. The failure molds were determined by interactions of EM behaviors and TMF damages.

  3. Benign joint hypermobility syndrome in soldiers; what is the effect of military training courses on associated joint instabilities?

    PubMed

    Azma, Kamran; Mottaghi, Peyman; Hosseini, Alireza; Abadi, Hossein Hassan; Nouraei, Mohammad Hadi

    2014-07-01

    Hypermobile joints are joints with beyond normal range of motion and may be associated with joint derangements. This study aimed to evaluate the prevalence of benign joint hypermobility syndrome (BJHS) among soldiers and effect of training courses on related joint instabilities. In a prospective cohort study on 721 soldiers of Iran Army in Isfahan in 2013 the prevalence of joint hypermobility was obtained by using Beighton criteria. Soldiers divided in two groups of healthy and suffered based on their scores. The prevalence of ankle sprain, shoulder and temporomandibular joint (TMJ) dislocations identified before beginning service by history-taking and reviewing paraclinical documents. After 3 months of military training, a recent occurrence of mentioned diseases was revaluated in two groups. The collected data were analyzed using SPSS-20 software using Independent-T and Chi-square tests. The frequency of BJHS before military training was 29.4%. After passing military training period, the incidence of ankle sprain was significantly higher in suffered group achieving the minimum Beighton score (BS) of 4 (4.3%, P = 0.03), 5 (5.5%, P = 0.005) and also 6 out of 9 (6.5%, P = 0.01). The incidence of TMJ dislocation was not significantly different based on a minimum score of 4, while it was higher in suffered group when considering the score of 5 (2.1%) and 6 (2.6%) for discrimination of two groups (P = 0.03). There was no significant difference between two groups in case of shoulder dislocation anyway. Military training can increase the incidence of ankle sprains and TMJ dislocations in hypermobility persons with higher BS in comparison with healthy people. Therefore, screening of joint hypermobility may be useful in identifying individuals at increased risk for joint instabilities.

  4. The cyclic fatigue behavior of adhesive joints

    NASA Astrophysics Data System (ADS)

    Kinloch, A. J.; Toh, T.

    1995-06-01

    In the last six months we have: (1) Concentrated our efforts on the fatigue failure of carbon-fiber PEEK/AFl63 lap joints, and in particular we have started to predict the life time of single-lap joints under cyclic fatigue loading. The analysis is based on data obtained from double cantilever beam (DCB) fracture mechanics tests; (2) Further, we have been successful in measuring the rate of crack growth in lap joints during fatigue fracture using ultrasonic scanning; (3) Preliminary test data on the static fracture of glass-fiber reinforced poly(phenylene sulphide) (PPS)/AF163 joints have also been studied; and (4) A comparison has been made in computing the critical strain energy release rate G(sub c) for the glass-fiber PPS/AF163 joints based on the compliance method, beam theory and corrected beam theory. The last method accounts for large non-linear deflections and the associated crack root rotations along with the necessary corrections for the increase in stiffness introduced by the presence of end blocks.

  5. Joint Operational Medicine Information Systems (JOMIS)

    DTIC Science & Technology

    2016-03-01

    Component is Program Executive Office (PEO) Department of Defense (DoD) Healthcare Management Systems (DHMS) for Defense Health Agency (DHA). Responsible...AT&L)) and the Program Executive Office (PEO) Defense Healthcare Management Systems (DHMS). ​Operational medicine is the application of routine and...acquired by the DoD Healthcare Management System Modernization (DHMSM) program for Health Care Delivery (HCD) capabilities. JOMIS future release(s

  6. The method of a joint intraday security check system based on cloud computing

    NASA Astrophysics Data System (ADS)

    Dong, Wei; Feng, Changyou; Zhou, Caiqi; Cai, Zhi; Dan, Xu; Dai, Sai; Zhang, Chuancheng

    2017-01-01

    The intraday security check is the core application in the dispatching control system. The existing security check calculation only uses the dispatch center’s local model and data as the functional margin. This paper introduces the design of all-grid intraday joint security check system based on cloud computing and its implementation. To reduce the effect of subarea bad data on the all-grid security check, a new power flow algorithm basing on comparison and adjustment with inter-provincial tie-line plan is presented. And the numerical example illustrated the effectiveness and feasibility of the proposed method.

  7. Operational rate-distortion performance for joint source and channel coding of images.

    PubMed

    Ruf, M J; Modestino, J W

    1999-01-01

    This paper describes a methodology for evaluating the operational rate-distortion behavior of combined source and channel coding schemes with particular application to images. In particular, we demonstrate use of the operational rate-distortion function to obtain the optimum tradeoff between source coding accuracy and channel error protection under the constraint of a fixed transmission bandwidth for the investigated transmission schemes. Furthermore, we develop information-theoretic bounds on performance for specific source and channel coding systems and demonstrate that our combined source-channel coding methodology applied to different schemes results in operational rate-distortion performance which closely approach these theoretical limits. We concentrate specifically on a wavelet-based subband source coding scheme and the use of binary rate-compatible punctured convolutional (RCPC) codes for transmission over the additive white Gaussian noise (AWGN) channel. Explicit results for real-world images demonstrate the efficacy of this approach.

  8. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, Herbert; Valenzuela, Javier A.; Nutt, William E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof.

  9. An analytical investigation of a conceptual design for the station transverse boom rotary joint structure

    NASA Technical Reports Server (NTRS)

    Lake, M. S.; Bush, H. G.

    1986-01-01

    A study was conducted to define an annular ring, discrete roller assembly concept for the space station transverse boom rotary joint. The concept was analyzed using closed-form and finite element techniques, to size structural members for a range of joint diameters and to determine necessary equivalent stiffnesses for the roller assemblies. Also, a mass study of the system was conducted to determine its practicality, and maximum loads in the joint were identified. To obtain the optimum balance between high stiffness and low structural mass in the design of the rotary joint, it is necessary to maximize the diameter of the annular ring within operational constraints (i.e., shuttle cargo bay size). Further, a rotary joint designed with the largest possible ring diameter will result in minimum operational loads in both the roller assemblies and the transition truss members while also allowing minimum design stiffnesses for the roller assemblies.

  10. Joint Operations 2030 - Final Report (Operations interarmees 2030 - Rapport final)

    DTIC Science & Technology

    2011-04-01

    case of crisis : • Technologies to support emergency management operations, inter-organisational coordination and communication , distributed...are made up of national representatives as well as generally recognised ‘world class’ scientists. They also provide a communication link to military...Other Entities H.4 Capable of Establishing and Maintaining Communication Channels and Liaison Relationships H-7 with Potential Service Providers

  11. Joint NASA Ames/Langley Experimental Evaluation of Integrated Air/Ground Operations for En Route Free Maneuvering

    NASA Technical Reports Server (NTRS)

    Barhydt, Richard; Kopardekar, Parimal; Battiste, Vernol; Doble, Nathan; Johnson, Walter; Lee, Paul; Prevot, Thomas; Smith, Nancy

    2005-01-01

    In order to meet the anticipated future demand for air travel, the National Aeronautics and Space Administration (NASA) is investigating a new concept of operations known as Distributed Air-Ground Traffic Management (DAG-TM). Under the En Route Free Maneuvering component of DAG-TM, appropriately equipped autonomous aircraft self separate from other autonomous aircraft and from managed aircraft that continue to fly under today s Instrument Flight Rules (IFR). Controllers provide separation services between IFR aircraft and assign traffic flow management constraints to all aircraft. To address concept feasibility issues pertaining to integrated air/ground operations at various traffic levels, NASA Ames and Langley Research Centers conducted a joint human-in-the-loop experiment. Professional airline pilots and air traffic controllers flew a total of 16 scenarios under four conditions: mixed autonomous/managed operations at three traffic levels and a baseline all-managed condition at the lowest traffic level. These scenarios included en route flights and descents to a terminal area meter fix in airspace modeled after the Dallas Ft. Worth area. Pilots of autonomous aircraft met controller assigned meter fix constraints with high success. Separation violations by subject pilots did not appear to vary with traffic level and were mainly attributable to software errors and procedural lapses. Controller workload was lower for mixed flight conditions, even at higher traffic levels. Pilot workload was deemed acceptable under all conditions. Controllers raised several safety concerns, most of which pertained to the occurrence of near-term conflicts between autonomous and managed aircraft. These issues are being addressed through better compatibility between air and ground systems and refinements to air and ground procedures.

  12. Operation Urgent Fury - Grenada

    DTIC Science & Technology

    1983-11-01

    Urgent Fury : the planning and execution of joint operations in Grenada, 12 October-2 November 1983 / Ronald H. Cole. p . cm...meeting, Secretary of State George P . Shultz and the Chairman of the Joint Chiefs of Staff, General John W. Vessey, Jr., USA, warned the Special Situation...Group (RIG) of the National Security Council (NSC), on 12 October, Langhorne A. Motley, Assistant Secretary of State for Inter-American Affairs

  13. Double symbolic joint entropy in nonlinear dynamic complexity analysis

    NASA Astrophysics Data System (ADS)

    Yao, Wenpo; Wang, Jun

    2017-07-01

    Symbolizations, the base of symbolic dynamic analysis, are classified as global static and local dynamic approaches which are combined by joint entropy in our works for nonlinear dynamic complexity analysis. Two global static methods, symbolic transformations of Wessel N. symbolic entropy and base-scale entropy, and two local ones, namely symbolizations of permutation and differential entropy, constitute four double symbolic joint entropies that have accurate complexity detections in chaotic models, logistic and Henon map series. In nonlinear dynamical analysis of different kinds of heart rate variability, heartbeats of healthy young have higher complexity than those of the healthy elderly, and congestive heart failure (CHF) patients are lowest in heartbeats' joint entropy values. Each individual symbolic entropy is improved by double symbolic joint entropy among which the combination of base-scale and differential symbolizations have best complexity analysis. Test results prove that double symbolic joint entropy is feasible in nonlinear dynamic complexity analysis.

  14. 14 CFR 141.25 - Business office and operations base.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Business office and operations base. 141.25... operations base. (a) Each holder of a pilot school or a provisional pilot school certificate must maintain a... or the operations base, each certificate holder must notify the FAA Flight Standards District Office...

  15. 14 CFR 141.25 - Business office and operations base.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Business office and operations base. 141.25... operations base. (a) Each holder of a pilot school or a provisional pilot school certificate must maintain a... or the operations base, each certificate holder must notify the FAA Flight Standards District Office...

  16. 14 CFR 141.25 - Business office and operations base.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Business office and operations base. 141.25... operations base. (a) Each holder of a pilot school or a provisional pilot school certificate must maintain a... or the operations base, each certificate holder must notify the FAA Flight Standards District Office...

  17. 14 CFR 141.25 - Business office and operations base.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Business office and operations base. 141.25... operations base. (a) Each holder of a pilot school or a provisional pilot school certificate must maintain a... or the operations base, each certificate holder must notify the FAA Flight Standards District Office...

  18. Decentralized control of large flexible structures by joint decoupling

    NASA Technical Reports Server (NTRS)

    Su, Tzu-Jeng; Juang, Jer-Nan

    1994-01-01

    This paper presents a novel method to design decentralized controllers for large complex flexible structures by using the idea of joint decoupling. Decoupling of joint degrees of freedom from the interior degrees of freedom is achieved by setting the joint actuator commands to cancel the internal forces exerting on the joint degrees of freedom. By doing so, the interactions between substructures are eliminated. The global structure control design problem is then decomposed into several substructure control design problems. Control commands for interior actuators are set to be localized state feedback using decentralized observers for state estimation. The proposed decentralized controllers can operate successfully at the individual substructure level as well as at the global structure level. Not only control design but also control implementation is decentralized. A two-component mass-spring-damper system is used as an example to demonstrate the proposed method.

  19. Knee joint replacement

    MedlinePlus

    ... Knee joint replacement - series References American Academy of Orthopedic Surgeons (AAOS) website. Treatment of osteoarthritis of the knee: evidence-based guideline 2nd edition (summary) . www.aaos.org/research/guidelines/TreatmentofOsteoarthritisoftheKneeGuideline.pdf . Updated May 18, 2013. Accessed ...

  20. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  1. Planning and implementing forest operations to achieve sustainable forests: Proceedings of papers presented at the joint meeting of the Council on Forest Engineering and International Union of Forest Research Organizations.

    Treesearch

    Charles R. Blinn; Michael A. Thompson

    1996-01-01

    Contains a variety of papers presented at the joint meeting of the Council on Forest Engineering and International Union of Forest Research Organizations Subject Group S3.04 and that support the meeting theme "Planning and Implementing Forest Operations to Achieve Sustainable Forests."

  2. Flaw Tolerance In Lap Shear Brazed Joints. Part 2

    NASA Technical Reports Server (NTRS)

    Wang, Len; Flom, Yury

    2003-01-01

    This paper presents results of the second part of an on-going effort to gain better understanding of defect tolerance in braze joints. In the first part of this three-part series, we mechanically tested and modeled the strength of the lap joints as a function of the overlap distance. A failure criterion was established based on the zone damage theory, which predicts the dependence of the lap joint shear strength on the overlap distance, based on the critical size of a finite damage zone or an overloaded region in the joint. In this second part of the study, we experimentally verified the applicability of the damage zone criterion on prediction of the shear strength of the lap joint and introduced controlled flaws into the lap joints. The purpose of the study was to evaluate the lap joint strength as a function of flaw size and its location through mechanical testing and nonlinear finite element analysis (FEA) employing damage zone criterion for definition of failure. The results obtained from the second part of the investigation confirmed that the failure of the ductile lap shear brazed joints occurs when the damage zone reaches approximately 10% of the overlap width. The same failure criterion was applicable to the lap joints containing flaws.

  3. Tensor-product kernel-based representation encoding joint MRI view similarity.

    PubMed

    Alvarez-Meza, A; Cardenas-Pena, D; Castro-Ospina, A E; Alvarez, M; Castellanos-Dominguez, G

    2014-01-01

    To support 3D magnetic resonance image (MRI) analysis, a marginal image similarity (MIS) matrix holding MR inter-slice relationship along every axis view (Axial, Coronal, and Sagittal) can be estimated. However, mutual inference from MIS view information poses a difficult task since relationships between axes are nonlinear. To overcome this issue, we introduce a Tensor-Product Kernel-based Representation (TKR) that allows encoding brain structure patterns due to patient differences, gathering all MIS matrices into a single joint image similarity framework. The TKR training strategy is carried out into a low dimensional projected space to get less influence of voxel-derived noise. Obtained results for classifying the considered patient categories (gender and age) on real MRI database shows that the proposed TKR training approach outperforms the conventional voxel-wise sum of squared differences. The proposed approach may be useful to support MRI clustering and similarity inference tasks, which are required on template-based image segmentation and atlas construction.

  4. Lunar base surface mission operations. Lunar Base Systems Study (LBSS) task 4.1

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The purpose was to perform an analysis of the surface operations associated with a human-tended lunar base. Specifically, the study defined surface elements and developed mission manifests for a selected base scenario, determined the nature of surface operations associated with this scenario, generated a preliminary crew extravehicular and intravehicular activity (EVA/IVA) time resource schedule for conducting the missions, and proposed concepts for utilizing remotely operated equipment to perform repetitious or hazardous surface tasks. The operations analysis was performed on a 6 year period of human-tended lunar base operation prior to permanent occupancy. The baseline scenario was derived from a modified version of the civil needs database (CNDB) scenario. This scenario emphasizes achievement of a limited set of science and exploration objectives while emplacing the minimum habitability elements required for a permanent base.

  5. IRS memorandum limits joint ventures.

    PubMed

    Herman, A W

    1992-08-01

    Based on a new memorandum, the Internal Revenue Service (IRS) will be looking at joint hospital/physician activities with greater attention to the nuances of public versus private benefit. As a result, hospitals face greater risk of losing their tax-exempt status in the maze of joint ventures, physician recruitment, and practice acquisition. To be successful, ventures will have to be backed by sound reasoning and thorough documentation.

  6. Counterinsurgency and Operational Art: Is the Joint Campaign Planning Model Adequate?

    DTIC Science & Technology

    2003-01-01

    ART: IS THE JOINT CAMAPIGN PLANNING MODEL ADEQUATE? by MAJ Thomas Erik Miller, USA, 90 pages. The United States has conducted or supported more than a...increase. Some of the effects of the fall of the Soviet Union were a loosening of internal and external political and social controls in formerly Soviet...order” in the social , economic and political arena through rapid growth in population and urbanization in the underdeveloped world, globalization and

  7. Cooperative Engineering as a Joint Action

    ERIC Educational Resources Information Center

    Joffredo-Le Brun, Sophie; Morellato, Mireille; Sensevy, Gérard; Quilio, Serge

    2018-01-01

    This paper describes some elements of a specific kind of design-based research, cooperative engineering. In the first part of the paper, we argue that cooperative engineering can be analyzed through a joint action framework. We first present some conceptual tools that the Joint Action Theory in Didactics proposes in order to understand didactic…

  8. Overcoming Robot-Arm Joint Singularities

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Houck, J. A.

    1986-01-01

    Kinematic equations allow arm to pass smoothly through singular region. Report discusses mathematical singularities in equations of robotarm control. Operator commands robot arm to move in direction relative to its own axis system by specifying velocity in that direction. Velocity command then resolved into individual-joint rotational velocities in robot arm to effect motion. However, usual resolved-rate equations become singular when robot arm is straightened.

  9. Multiple linear regression approach for the analysis of the relationships between joints mobility and regional pressure-based parameters in the normal-arched foot.

    PubMed

    Caravaggi, Paolo; Leardini, Alberto; Giacomozzi, Claudia

    2016-10-03

    Plantar load can be considered as a measure of the foot ability to transmit forces at the foot/ground, or foot/footwear interface during ambulatory activities via the lower limb kinematic chain. While morphological and functional measures have been shown to be correlated with plantar load, no exhaustive data are currently available on the possible relationships between range of motion of foot joints and plantar load regional parameters. Joints' kinematics from a validated multi-segmental foot model were recorded together with plantar pressure parameters in 21 normal-arched healthy subjects during three barefoot walking trials. Plantar pressure maps were divided into six anatomically-based regions of interest associated to corresponding foot segments. A stepwise multiple regression analysis was performed to determine the relationships between pressure-based parameters, joints range of motion and normalized walking speed (speed/subject height). Sagittal- and frontal-plane joint motion were those most correlated to plantar load. Foot joints' range of motion and normalized walking speed explained between 6% and 43% of the model variance (adjusted R 2 ) for pressure-based parameters. In general, those joints' presenting lower mobility during stance were associated to lower vertical force at forefoot and to larger mean and peak pressure at hindfoot and forefoot. Normalized walking speed was always positively correlated to mean and peak pressure at hindfoot and forefoot. While a large variance in plantar pressure data is still not accounted for by the present models, this study provides statistical corroboration of the close relationship between joint mobility and plantar pressure during stance in the normal healthy foot. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Relationship between leg extensor muscle strength and knee joint loading during gait before and after total knee arthroplasty.

    PubMed

    Vahtrik, Doris; Gapeyeva, Helena; Ereline, Jaan; Pääsuke, Mati

    2014-01-01

    The aim of the present study was to evaluate an isometric maximal voluntary contraction (MVC) force of the leg extensor muscles and its relationship with knee joint loading during gait prior and after total knee arthroplasty (TKA). Custom-made dynamometer was used to assess an isometric MVC force of the leg extensor muscles and 3-D motion analysis system was used to evaluate the knee joint loading during gait in 13 female patients (aged 49-68 years) with knee osteoarthritis. Patients were evaluated one day before, and three and six months following TKA in the operated and non-operated leg. Six months after TKA, MVC force of the leg extensor muscles for the operated leg did not differ significantly as compared to the preoperative level, whereas it remained significantly lower for the non-operated leg and controls. The knee flexion moment and the knee joint power during mid stance of gait was improved six months after TKA, remaining significantly lowered compared with controls. Negative moderate correlation between leg extensor muscles strength and knee joint loading for the operated leg during mid stance was noted three months after TKA. The correlation analysis indicates that due to weak leg extensor muscles, an excessive load is applied to knee joint during mid stance of gait in patients, whereas in healthy subjects stronger knee-surrounding muscles provide stronger knee joint loading during gait. III (correlational study). Copyright © 2013 Elsevier B.V. All rights reserved.

  11. A clamping force measurement system for monitoring the condition of bolted joints on railway track joints and points

    NASA Astrophysics Data System (ADS)

    Tesfa, B.; Horler, G.; Thobiani, F. Al; Gu, F.; Ball, A. D.

    2012-05-01

    Many industrial structures associated with railway infrastructures rely on a large number of bolted joint connections to ensure safe and reliable operation of the track and trackside furniture. Significant sums of money are spent annually to repair the damage caused by bolt failures and to maintain the integrity of bolted structures. In the UK, Network Rail (the organization responsible for rail network maintenance and safety) conducts corrective and preventive maintenance manually on 26,000 sets of points (each having approximately 30 bolted joints per set), in order to ensure operational success and safety for the travelling public. Such manual maintenance is costly, disruptive, unreliable and prone to human error. The aim of this work is to provide a means of automatically measuring the clamping force of each individual bolted joint, by means of an instrumented washer. This paper describes the development of a sensor means to be used in the washer, which satisfies the following criteria. Sense changes in the clamping force of the joint and report this fact. Provide compatibility with the large dynamic range of clamping force. Satisfy the limitations in terms of physical size. Provide the means to electronically interface with the washer. Provide a means of powering the washer in situ. Provide a solution at an acceptable cost. Specifically the paper focuses on requirements 1, 2 and 3 and presents the results that support further development of the proposed design and the realization of a pre-prototype system. In the paper, various options for the force sensing element (strain gage, capacitor, piezo-resistive) have been compared, using design optimization techniques. As a result of the evaluation, piezo-resistive sensors in concert with a proprietary force attenuation method, have been found to offer the best performance and cost trade-off The performance of the novel clamping force sensor has been evaluated experimentally and the results show that a smart washer

  12. International Peacekeeping Operations

    PubMed Central

    2017-01-01

    This article takes stock of some of the important contributions to the study of peacekeeping (PK). Two key topics stand out: peacekeeping burden sharing and mission effectiveness. For burden sharing, the theoretical foundation is the private provision of public goods and joint products. Implications for burden sharing differ whether financial or troop contributions are being shared, with the latter driven by jointly produced country-specific benefits. Financial burden sharing can also differ between United Nations (UN)-led and non-UN-led peacekeeping operations, wherein country-specific benefits are especially important for the latter. Many articles gauge peacekeeping effectiveness by the mission’s ability to maintain the peace or to protect lives for a set time period. More recently, multiple criteria are raised for evaluating peacekeeping in today’s world of multifaceted peacebuilding operations. PMID:28989181

  13. Time-lapse joint AVO inversion using generalized linear method based on exact Zoeppritz equations

    NASA Astrophysics Data System (ADS)

    Zhi, Longxiao; Gu, Hanming

    2018-03-01

    The conventional method of time-lapse AVO (Amplitude Versus Offset) inversion is mainly based on the approximate expression of Zoeppritz equations. Though the approximate expression is concise and convenient to use, it has certain limitations. For example, its application condition is that the difference of elastic parameters between the upper medium and lower medium is little and the incident angle is small. In addition, the inversion of density is not stable. Therefore, we develop the method of time-lapse joint AVO inversion based on exact Zoeppritz equations. In this method, we apply exact Zoeppritz equations to calculate the reflection coefficient of PP wave. And in the construction of objective function for inversion, we use Taylor series expansion to linearize the inversion problem. Through the joint AVO inversion of seismic data in baseline survey and monitor survey, we can obtain the P-wave velocity, S-wave velocity, density in baseline survey and their time-lapse changes simultaneously. We can also estimate the oil saturation change according to inversion results. Compared with the time-lapse difference inversion, the joint inversion doesn't need certain assumptions and can estimate more parameters simultaneously. It has a better applicability. Meanwhile, by using the generalized linear method, the inversion is easily implemented and its calculation cost is small. We use the theoretical model to generate synthetic seismic records to test and analyze the influence of random noise. The results can prove the availability and anti-noise-interference ability of our method. We also apply the inversion to actual field data and prove the feasibility of our method in actual situation.

  14. Wide temperature range seal for demountable joints

    DOEpatents

    Sixsmith, H.; Valenzuela, J.A.; Nutt, W.E.

    1991-07-23

    The present invention is directed to a seal for demountable joints operating over a wide temperature range down to liquid helium temperatures. The seal has anti-extrusion guards which prevent extrusion of the soft ductile sealant material, which may be indium or an alloy thereof. 6 figures.

  15. Acute Ankle Sprain in a Mouse Model: Changes in Knee-Joint Space

    PubMed Central

    Wikstrom, Erik A.; Guderian, Sophie; Turner, Michael J.

    2017-01-01

    Context:  Ankle sprains remain the most common orthopaedic injury. Conducting long-term studies in humans is difficult and costly, so the long-term consequences of an ankle sprain are not entirely known. Objective:  To measure knee-joint space after a single surgically induced ankle sprain in mice. Design:  Randomized controlled trial. Setting:  University research laboratory. Patients or Other Participants:  Thirty male mice (CBA/2J) were randomly placed into 1 of 3 surgical groups: the transected calcaneofibular ligament (CFL) group, the transected anterior talofibular ligament/CFL group, or a sham treatment group. The right ankle was operated on in all mice. Main Outcome Measure(s):  Three days after surgery, all of the mice were individually housed in cages containing a solid-surface running wheel, and daily running-wheel measurements were recorded. Before surgery and every 6 weeks after surgery, a diagnostic ultrasound was used to measure medial and lateral knee-joint space in both hind limbs. Results:  Right medial (P = .003), right lateral (P = .002), left medial (P = .03), and left lateral (P = .002) knee-joint spaces decreased across the life span. The mice in the anterior talofibular ligament/CFL group had decreased right medial (P = .004) joint space compared with the sham and CFL groups starting at 24 weeks of age and continuing throughout the life span. No differences occurred in contralateral knee-joint degeneration among any of the groups. Conclusions:  Based on current data, mice that sustained a surgically induced severe ankle sprain developed greater joint degeneration in the ipsilateral knee. Knee degeneration could result from accommodation to the laxity of the ankle or biomechanical alterations secondary to ankle instability. A single surgically induced ankle sprain could significantly affect knee-joint function. PMID:28437129

  16. Establishing Operational Access: Insights from the Past for the Future

    DTIC Science & Technology

    2014-06-01

    Combined Bomber Offensive, the Yom Kippur War, and Operation Mole Cricket 19 identifies two tenets that must be incorporated into the next iteration of...Mole Cricket 19 identifies two tenets that must be incorporated into the next iteration of the Joint Operational Access Concept. First, the Joint...They are the Battle of Britain, the Combined Bomber Offensive, the Yom Kippur War, and Operation Mole Cricket 19. These examples were selected

  17. Designing and validating the joint battlespace infosphere

    NASA Astrophysics Data System (ADS)

    Peterson, Gregory D.; Alexander, W. Perry; Birdwell, J. Douglas

    2001-08-01

    Fielding and managing the dynamic, complex information systems infrastructure necessary for defense operations presents significant opportunities for revolutionary improvements in capabilities. An example of this technology trend is the creation and validation of the Joint Battlespace Infosphere (JBI) being developed by the Air Force Research Lab. The JBI is a system of systems that integrates, aggregates, and distributes information to users at all echelons, from the command center to the battlefield. The JBI is a key enabler of meeting the Air Force's Joint Vision 2010 core competencies such as Information Superiority, by providing increased situational awareness, planning capabilities, and dynamic execution. At the same time, creating this new operational environment introduces significant risk due to an increased dependency on computational and communications infrastructure combined with more sophisticated and frequent threats. Hence, the challenge facing the nation is the most effective means to exploit new computational and communications technologies while mitigating the impact of attacks, faults, and unanticipated usage patterns.

  18. Resident accuracy of joint line palpation using ultrasound verification.

    PubMed

    Rho, Monica E; Chu, Samuel K; Yang, Aaron; Hameed, Farah; Lin, Cindy Yuchin; Hurh, Peter J

    2014-10-01

    To determine the accuracy of knee and acromioclavicular (AC) joint line palpation in Physical Medicine and Rehabilitation (PM&R) residents using ultrasound (US) verification. Cohort study. PM&R residency program at an academic institution. Twenty-four PM&R residents participating in a musculoskeletal US course (7 PGY-2, 8 PGY-3, and 9 PGY4 residents). Twenty-four PM&R residents participating in an US course were asked to palpate the AC joint and lateral joint line of the knee in a female and male model before the start of the course. Once the presumed joint line was localized, the residents were asked to tape an 18-gauge, 1.5-inch, blunt-tip needle parallel to the joint line on the overlying skin. The accuracy of needle placement over the joint line was verified using US. US verification of correct needle placement over the joint line. Overall AC joint palpation accuracy was 16.7%, and knee lateral joint line palpation accuracy was 58.3%. Based on the resident level of education, using a value of P < .05, there were no statistically significant differences in the accuracy of joint line palpation. Residents in this study demonstrate poor accuracy of AC joint and lateral knee joint line identification by palpation, using US as the criterion standard for verification. There were no statistically significant differences in the accuracy rates of joint line palpation based on resident level of education. US may be a useful tool to use to advance the current methods of teaching the physical examination in medical education. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  19. The validation of a human force model to predict dynamic forces resulting from multi-joint motions

    NASA Technical Reports Server (NTRS)

    Pandya, Abhilash K.; Maida, James C.; Aldridge, Ann M.; Hasson, Scott M.; Woolford, Barbara J.

    1992-01-01

    The development and validation is examined of a dynamic strength model for humans. This model is based on empirical data. The shoulder, elbow, and wrist joints were characterized in terms of maximum isolated torque, or position and velocity, in all rotational planes. This data was reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining torque as a function of position and velocity. The isolated joint torque equations were then used to compute forces resulting from a composite motion, in this case, a ratchet wrench push and pull operation. A comparison of the predicted results of the model with the actual measured values for the composite motion indicates that forces derived from a composite motion of joints (ratcheting) can be predicted from isolated joint measures. Calculated T values comparing model versus measured values for 14 subjects were well within the statistically acceptable limits and regression analysis revealed coefficient of variation between actual and measured to be within 0.72 and 0.80.

  20. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.