Sample records for joint contact patterns

  1. In Vivo Measurement of Glenohumeral Joint Contact Patterns

    NASA Astrophysics Data System (ADS)

    Bey, Michael J.; Kline, Stephanie K.; Zauel, Roger; Kolowich, Patricia A.; Lock, Terrence R.

    2009-12-01

    The objectives of this study were to describe a technique for measuring in-vivo glenohumeral joint contact patterns during dynamic activities and to demonstrate application of this technique. The experimental technique calculated joint contact patterns by combining CT-based 3D bone models with joint motion data that were accurately measured from biplane x-ray images. Joint contact patterns were calculated for the repaired and contralateral shoulders of 20 patients who had undergone rotator cuff repair. Significant differences in joint contact patterns were detected due to abduction angle and shoulder condition (i.e., repaired versus contralateral). Abduction angle had a significant effect on the superior/inferior contact center position, with the average joint contact center of the repaired shoulder 12.1% higher on the glenoid than the contralateral shoulder. This technique provides clinically relevant information by calculating in-vivo joint contact patterns during dynamic conditions and overcomes many limitations associated with conventional techniques for quantifying joint mechanics.

  2. Joint contact loading in forefoot and rearfoot strike patterns during running.

    PubMed

    Rooney, Brandon D; Derrick, Timothy R

    2013-09-03

    Research concerning forefoot strike pattern (FFS) versus rearfoot strike pattern (RFS) running has focused on the ground reaction force even though internal joint contact forces are a more direct measure of the loads responsible for injury. The main purpose of this study was to determine the internal loading of the joints for each strike pattern. A secondary purpose was to determine if converted FFS and RFS runners can adequately represent habitual runners with regards to the internal joint loading. Using inverse dynamics to calculate the net joint moments and reaction forces and optimization techniques to estimate muscle forces, we determined the axial compressive loading at the ankle, knee, and hip. Subjects consisted of 15 habitual FFS and 15 habitual RFS competitive runners. Each subject ran at a preferred running velocity with their habitual strike pattern and then converted to the opposite strike pattern. Plantar flexor muscle forces and net ankle joint moments were greater in the FFS running compared to the RFS running during the first half of the stance phase. The average contact forces during this period increased by 41.7% at the ankle and 14.4% at the knee joint during FFS running. Peak ankle joint contact force was 1.5 body weights greater during FFS running (p<0.05). There was no evidence to support a difference between habitual and converted running for joint contact forces. The increased loading at the ankle joint for FFS is an area of concern for individuals considering altering their foot strike pattern. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Influence of altered gait patterns on the hip joint contact forces.

    PubMed

    Carriero, Alessandra; Zavatsky, Amy; Stebbins, Julie; Theologis, Tim; Lenaerts, Gerlinde; Jonkers, Ilse; Shefelbine, Sandra J

    2014-01-01

    Children who exhibit gait deviations often present a range of bone deformities, particularly at the proximal femur. Altered gait may affect bone growth and lead to deformities by exerting abnormal stresses on the developing bones. The objective of this study was to calculate variations in the hip joint contact forces with different gait patterns. Muscle and hip joint contact forces of four children with different walking characteristics were calculated using an inverse dynamic analysis and a static optimisation algorithm. Kinematic and kinetic analyses were based on a generic musculoskeletal model scaled down to accommodate the dimensions of each child. Results showed that for all the children with altered gaits both the orientation and magnitude of the hip joint contact force deviated from normal. The child with the most severe gait deviations had hip joint contact forces 30% greater than normal, most likely due to the increase in muscle forces required to sustain his crouched stance. Determining how altered gait affects joint loading may help in planning treatment strategies to preserve correct loading on the bone from a young age.

  4. Lateral ligament repair and reconstruction restore neither contact mechanics of the ankle joint nor motion patterns of the hindfoot.

    PubMed

    Prisk, Victor R; Imhauser, Carl W; O'Loughlin, Padhraig F; Kennedy, John G

    2010-10-20

    Ankle sprains may damage both the lateral ligaments of the hindfoot and the osteochondral tissue of the ankle joint. When nonoperative treatment fails, operative approaches are indicated to restore both native motion patterns at the hindfoot and ankle joint contact mechanics. The goal of the present study was to determine the effect of lateral ligament injury, repair, and reconstruction on ankle joint contact mechanics and hindfoot motion patterns. Eight cadaveric specimens were tested with use of robotic technology to apply combined compressive (200-N) and inversion (4.5-Nm) loads to the hindfoot at 0° and 20° of plantar flexion. Contact mechanics at the ankle joint were simultaneously measured. A repeated-measures experiment was designed with use of the intact condition as control, with the other conditions including sectioned anterior talofibular and calcaneofibular ligaments, the Broström and Broström-Gould repairs, and graft reconstruction. Ligament sectioning decreased contact area and caused a medial and anterior shift in the center of pressure with inversion loads relative to those with the intact condition. There were no significant differences in inversion or coupled axial rotation with inversion between the Broström repair and the intact condition; however, medial translation of the center of pressure remained elevated after the Broström repair relative to the intact condition. The Gould modification of the Broström procedure provided additional support to the hindfoot relative to the Broström repair, reducing inversion and axial rotation with inversion beyond that of intact ligaments. There were no significant differences in center-of-pressure excursion patterns between the Broström-Gould repair and the intact ligament condition, but this repair increased contact area beyond that with the ligaments intact. Graft reconstruction more closely restored inversion motion than did the Broström-Gould repair at 20° of plantar flexion but limited

  5. Lateral Ligament Repair and Reconstruction Restore Neither Contact Mechanics of the Ankle Joint nor Motion Patterns of the Hindfoot

    PubMed Central

    Prisk, Victor R.; Imhauser, Carl W.; O'Loughlin, Padhraig F.; Kennedy, John G.

    2010-01-01

    Background: Ankle sprains may damage both the lateral ligaments of the hindfoot and the osteochondral tissue of the ankle joint. When nonoperative treatment fails, operative approaches are indicated to restore both native motion patterns at the hindfoot and ankle joint contact mechanics. The goal of the present study was to determine the effect of lateral ligament injury, repair, and reconstruction on ankle joint contact mechanics and hindfoot motion patterns. Methods: Eight cadaveric specimens were tested with use of robotic technology to apply combined compressive (200-N) and inversion (4.5-Nm) loads to the hindfoot at 0° and 20° of plantar flexion. Contact mechanics at the ankle joint were simultaneously measured. A repeated-measures experiment was designed with use of the intact condition as control, with the other conditions including sectioned anterior talofibular and calcaneofibular ligaments, the Broström and Broström-Gould repairs, and graft reconstruction. Results: Ligament sectioning decreased contact area and caused a medial and anterior shift in the center of pressure with inversion loads relative to those with the intact condition. There were no significant differences in inversion or coupled axial rotation with inversion between the Broström repair and the intact condition; however, medial translation of the center of pressure remained elevated after the Broström repair relative to the intact condition. The Gould modification of the Broström procedure provided additional support to the hindfoot relative to the Broström repair, reducing inversion and axial rotation with inversion beyond that of intact ligaments. There were no significant differences in center-of-pressure excursion patterns between the Broström-Gould repair and the intact ligament condition, but this repair increased contact area beyond that with the ligaments intact. Graft reconstruction more closely restored inversion motion than did the Broström-Gould repair at 20° of

  6. Joint Contact Stress

    PubMed Central

    Brand, Richard A

    2005-01-01

    A joint's normal mechanical history contributes to the maintenance of articular cartilage and underlying bone. Loading facilitates the flow of nutrients into cartilage and waste products away, and additionally provides the mechanical signals essential for normal cell and tissue maintenance. Deleteriously low or high contact stresses have been presumed to result in joint deterioration, and particular aspects of the mechanical environment may facilitate repair of damaged cartilage. For decades, investigators have explored static joint contact stresses (under some more or less arbitrary condition) as a surrogate of the relevant mechanical history. Contact stresses have been estimated in vitro in many joints and in a number of species, although only rarely in vivo. Despite a number of widely varying techniques (and spatial resolutions) to measure these contact stresses, reported ranges of static peak normal stresses are relatively similar from joint to joint across species, and in the range of 0.5 to 5.0 MPa. This suggests vertebrate diarthrodial joints have evolved to achieve similar mechanical design criteria. Available evidence also suggests some disorders of cartilage deterioration are associated with somewhat higher peak pressures ranging from 1-20 MPa, but overlapping the range of normal pressures. Some evidence and considerable logic suggests static contact stresses per se do not predict cartilage responses, but rather temporal aspects of the contact stress history. Static contact stresses may therefore not be a reasonable surrogate for biomechanical studies. Rather, temporal and spatial aspects of the loading history undoubtedly induce beneficial and deleterious biological responses. Finally, since all articular cartilage experiences similar stresses, the concept of a "weight-bearing" versus a "non-weight-bearing" joint seems flawed, and should be abandoned. PMID:16089079

  7. [Determination of joint contact area using MRI].

    PubMed

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  8. Predictive Simulations of Neuromuscular Coordination and Joint-Contact Loading in Human Gait.

    PubMed

    Lin, Yi-Chung; Walter, Jonathan P; Pandy, Marcus G

    2018-04-18

    We implemented direct collocation on a full-body neuromusculoskeletal model to calculate muscle forces, ground reaction forces and knee contact loading simultaneously for one cycle of human gait. A data-tracking collocation problem was solved for walking at the normal speed to establish the practicality of incorporating a 3D model of articular contact and a model of foot-ground interaction explicitly in a dynamic optimization simulation. The data-tracking solution then was used as an initial guess to solve predictive collocation problems, where novel patterns of movement were generated for walking at slow and fast speeds, independent of experimental data. The data-tracking solutions accurately reproduced joint motion, ground forces and knee contact loads measured for two total knee arthroplasty patients walking at their preferred speeds. RMS errors in joint kinematics were < 2.0° for rotations and < 0.3 cm for translations while errors in the model-computed ground-reaction and knee-contact forces were < 0.07 BW and < 0.4 BW, respectively. The predictive solutions were also consistent with joint kinematics, ground forces, knee contact loads and muscle activation patterns measured for slow and fast walking. The results demonstrate the feasibility of performing computationally-efficient, predictive, dynamic optimization simulations of movement using full-body, muscle-actuated models with realistic representations of joint function.

  9. Contribution of tibiofemoral joint contact to net loads at the knee in gait.

    PubMed

    Walter, Jonathan P; Korkmaz, Nuray; Fregly, Benjamin J; Pandy, Marcus G

    2015-07-01

    Inverse dynamics analysis is commonly used to estimate the net loads at a joint during human motion. Most lower-limb models of movement represent the knee as a simple hinge joint when calculating muscle forces. This approach is limited because it neglects the contributions from tibiofemoral joint contact forces and may therefore lead to errors in estimated muscle forces. The aim of this study was to quantify the contributions of tibiofemoral joint contact loads to the net knee loads calculated from inverse dynamics for multiple subjects and multiple gait patterns. Tibiofemoral joint contact loads were measured in four subjects with instrumented implants as each subject walked at their preferred speed (normal gait) and performed prescribed gait modifications designed to treat medial knee osteoarthritis. Tibiofemoral contact loads contributed substantially to the net knee extension and knee adduction moments in normal gait with mean values of 16% and 54%, respectively. These findings suggest that knee-contact kinematics and loads should be included in lower-limb models of movement for more accurate determination of muscle forces. The results of this study may be used to guide the development of more realistic lower-limb models that account for the effects of tibiofemoral joint contact at the knee. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Altered Tibiofemoral Joint Contact Mechanics and Kinematics in Patients with Knee Osteoarthritis and Episodic Complaints of Joint Instability

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Klatt, Brian A.; Gustafson, Jonathan A.; Tashman, Scott; Fitzgerald, G. Kelley

    2014-01-01

    Background To evaluate knee joint contact mechanics and kinematics during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. Methods Forty-three subjects, 11 with medial compartment knee osteoarthritis and self-reported instability (unstable), 7 with medial compartment knee osteoarthritis but no reports of instability (stable), and 25 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a downhill gait task on a treadmill. Findings The medial compartment contact point excursions were longer in the unstable group compared to the stable (p=0.046) and the control groups (p=0.016). The peak medial compartment contact point velocity was also greater for the unstable group compared to the stable (p=0.047) and control groups (p=0.022). Additionally, the unstable group demonstrated a coupled movement pattern of knee extension and external rotation after heel contact which was different than the coupled motion of knee flexion and internal rotation demonstrated by stable and control groups. Interpretation Our findings suggest that knee joint contact mechanics and kinematics are altered during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. The observed longer medial compartment contact point excursions and higher velocities represent objective signs of mechanical instability that may place the arthritic knee joint at increased risk for disease progression. Further research is indicated to explore the clinical relevance of altered contact mechanics and kinematics during other common daily activities and to assess the efficacy of rehabilitation programs to improve altered joint biomechanics in knee osteoarthritis patients with self-reported instability. PMID:24856791

  11. Gulf Coast Joint Venture - Contact Us

    Science.gov Websites

    Contact us Gulf Coast Joint Venture Wetland and Aquatic Research Center 700 Cajundome Blvd. Lafayette, LA Coast Joint Venture - 700 Cajundome Blvd. - Lafayette, LA 70506 Phone: 337-266-8801 Fax: 337-266-8800

  12. In Vivo Talocrural Joint Contact Mechanics With Functional Ankle Instability.

    PubMed

    Kobayashi, Takumi; Suzuki, Eiichi; Yamazaki, Naohito; Suzukawa, Makoto; Akaike, Atsushi; Shimizu, Kuniaki; Gamada, Kazuyoshi

    2015-12-01

    Functional ankle instability (FAI) may involve abnormal kinematics and contact mechanics during ankle internal rotation. Understanding of these abnormalities is important to prevent secondary problems in patients with FAI. However, there are no in vivo studies that have investigated talocrural joint contact mechanics during weightbearing ankle internal rotation. The objective of this study to determine talocrural contact mechanics during weightbearing ankle internal rotation in patients with FAI. Twelve male subjects with unilateral FAI (age range, 18-26 years) were enrolled. Computed tomography and fluoroscopic imaging of both lower extremities were obtained during weightbearing passive ankle joint complex rotation. Three-dimensional bone models created from the computed tomographic images were matched to the fluoroscopic images to compute 6 degrees of freedom for talocrural joint kinematics. The closest contact area in the talocrural joint in ankle neutral rotation and maximum internal rotation during either dorsiflexion or plantar flexion was determined using geometric bone models and talocrural joint kinematics data. The closest contact area in the talus shifted anteromedially during ankle dorsiflexion-internal rotation, whereas it shifted posteromedially during ankle plantar flexion-internal rotation. The closest contact area in FAI joints was significantly more medial than that in healthy joints during maximum ankle internal rotation and was associated with excessive talocrural internal rotation or inversion. This study demonstrated abnormal talocrural kinematics and contact mechanics in FAI subjects. Such abnormal kinematics may contribute to abnormal contact mechanics and may increase cartilage stress in FAI joints. Therapeutic, Level IV: cross-sectional case-control study. © 2015 The Author(s).

  13. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    PubMed

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  14. Intra-Articular Knee Contact Force Estimation During Walking Using Force-Reaction Elements and Subject-Specific Joint Model.

    PubMed

    Jung, Yihwan; Phan, Cong-Bo; Koo, Seungbum

    2016-02-01

    Joint contact forces measured with instrumented knee implants have not only revealed general patterns of joint loading but also showed individual variations that could be due to differences in anatomy and joint kinematics. Musculoskeletal human models for dynamic simulation have been utilized to understand body kinetics including joint moments, muscle tension, and knee contact forces. The objectives of this study were to develop a knee contact model which can predict knee contact forces using an inverse dynamics-based optimization solver and to investigate the effect of joint constraints on knee contact force prediction. A knee contact model was developed to include 32 reaction force elements on the surface of a tibial insert of a total knee replacement (TKR), which was embedded in a full-body musculoskeletal model. Various external measurements including motion data and external force data during walking trials of a subject with an instrumented knee implant were provided from the Sixth Grand Challenge Competition to Predict in vivo Knee Loads. Knee contact forces in the medial and lateral portions of the instrumented knee implant were also provided for the same walking trials. A knee contact model with a hinge joint and normal alignment could predict knee contact forces with root mean square errors (RMSEs) of 165 N and 288 N for the medial and lateral portions of the knee, respectively, and coefficients of determination (R2) of 0.70 and -0.63. When the degrees-of-freedom (DOF) of the knee and locations of leg markers were adjusted to account for the valgus lower-limb alignment of the subject, RMSE values improved to 144 N and 179 N, and R2 values improved to 0.77 and 0.37, respectively. The proposed knee contact model with subject-specific joint model could predict in vivo knee contact forces with reasonable accuracy. This model may contribute to the development and improvement of knee arthroplasty.

  15. Patellofemoral joint stress during running with alterations in foot strike pattern.

    PubMed

    Vannatta, Charles Nathan; Kernozek, Thomas W

    2015-05-01

    This study aimed to quantify differences in patellofemoral joint stress that may occur when healthy runners alter their foot strike pattern from their habitual rearfoot strike to a forefoot strike to gain insight on the potential etiology and treatment methods of patellofemoral pain. Sixteen healthy female runners completed 20 running trials in a controlled laboratory setting under rearfoot strike and forefoot strike conditions. Kinetic and kinematic data were used to drive a static optimization technique to estimate individual muscle forces to input into a model of the patellofemoral joint to estimate joint stress during running. Peak patellofemoral joint stress and the stress-time integral over stance phase decreased by 27% and 12%, respectively, in the forefoot strike condition (P < 0.001). Peak vertical ground reaction force increased slightly in the forefoot strike condition (P < 0.001). Peak quadriceps force and average hamstring force decreased, whereas gastrocnemius and soleus muscle forces increased when running with a forefoot strike (P < 0.05). Knee flexion angle at initial contact increased (P < 0.001), total knee excursion decreased (P < 0.001), and no change occurred in peak knee flexion angle (P = 0.238). Step length did not change between conditions (P = 0.375), but the leading leg landed with the foot positioned with a horizontal distance closer to the hip at initial contact in the forefoot strike condition (P < 0.001). Altering one's strike pattern to a forefoot strike results in consistent reductions in patellofemoral joint stress independent of changes in step length. Thus, implementation of forefoot strike training programs may be warranted in the treatment of runners with patellofemoral pain. However, it is suggested that the transition to a forefoot strike pattern should be completed in a graduated manner.

  16. Surrogate modeling of deformable joint contact using artificial neural networks.

    PubMed

    Eskinazi, Ilan; Fregly, Benjamin J

    2015-09-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Surrogate Modeling of Deformable Joint Contact using Artificial Neural Networks

    PubMed Central

    Eskinazi, Ilan; Fregly, Benjamin J.

    2016-01-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. PMID:26220591

  18. An Open-Source Toolbox for Surrogate Modeling of Joint Contact Mechanics

    PubMed Central

    Eskinazi, Ilan

    2016-01-01

    Goal Incorporation of elastic joint contact models into simulations of human movement could facilitate studying the interactions between muscles, ligaments, and bones. Unfortunately, elastic joint contact models are often too expensive computationally to be used within iterative simulation frameworks. This limitation can be overcome by using fast and accurate surrogate contact models that fit or interpolate input-output data sampled from existing elastic contact models. However, construction of surrogate contact models remains an arduous task. The aim of this paper is to introduce an open-source program called Surrogate Contact Modeling Toolbox (SCMT) that facilitates surrogate contact model creation, evaluation, and use. Methods SCMT interacts with the third party software FEBio to perform elastic contact analyses of finite element models and uses Matlab to train neural networks that fit the input-output contact data. SCMT features sample point generation for multiple domains, automated sampling, sample point filtering, and surrogate model training and testing. Results An overview of the software is presented along with two example applications. The first example demonstrates creation of surrogate contact models of artificial tibiofemoral and patellofemoral joints and evaluates their computational speed and accuracy, while the second demonstrates the use of surrogate contact models in a forward dynamic simulation of an open-chain leg extension-flexion motion. Conclusion SCMT facilitates the creation of computationally fast and accurate surrogate contact models. Additionally, it serves as a bridge between FEBio and OpenSim musculoskeletal modeling software. Significance Researchers may now create and deploy surrogate models of elastic joint contact with minimal effort. PMID:26186761

  19. Joint moments and contact forces in the foot during walking.

    PubMed

    Kim, Yongcheol; Lee, Kyoung Min; Koo, Seungbum

    2018-06-06

    The net force and moment of a joint have been widely used to understand joint disease in the foot. Meanwhile, it does not reflect the physiological forces on muscles and contact surfaces. The objective of the study is to estimate active moments by muscles, passive moments by connective tissues and joint contact forces in the foot joints during walking. Joint kinematics and external forces of ten healthy subjects (all males, 24.7 ± 1.2 years) were acquired during walking. The data were entered into the five-segment musculoskeletal foot model to calculate muscle forces and joint contact forces of the foot joints using an inverse dynamics-based optimization. Joint reaction forces and active, passive and net moments of each joint were calculated from muscle and ligament forces. The maximum joint reaction forces were 8.72, 4.31, 2.65, and 3.41 body weight (BW) for the ankle, Chopart's, Lisfranc and metatarsophalangeal joints, respectively. Active and passive moments along with net moments were also obtained. The maximum net moments were 8.6, 8.4, 5.4 and 0.8%BW∙HT, respectively. While the trend of net moment was very similar between the four joints, the magnitudes and directions of the active and passive moments varied between joints. The active and passive moments during walking could reveal the roles of muscles and ligaments in each of the foot joints, which was not obvious in the net moment. This method may help narrow down the source of joint problems if applied to clinical studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces.

    PubMed

    Gerus, Pauline; Sartori, Massimo; Besier, Thor F; Fregly, Benjamin J; Delp, Scott L; Banks, Scott A; Pandy, Marcus G; D'Lima, Darryl D; Lloyd, David G

    2013-11-15

    Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle-tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model. © 2013 Published by Elsevier Ltd.

  1. Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces

    PubMed Central

    Gerus, Pauline; Sartori, Massimo; Besier, Thor F.; Fregly, Benjamin J.; Delp, Scott L.; Banks, Scott A.; Pandy, Marcus G.; D’Lima, Darryl D.; Lloyd, David G.

    2013-01-01

    Estimating tibiofemoral joint contact forces is important for understanding the initiation and progression of knee osteoarthritis. However, tibiofemoral contact force predictions are influenced by many factors including muscle forces and anatomical representations of the knee joint. This study aimed to investigate the influence of subject-specific geometry and knee joint kinematics on the prediction of tibiofemoral contact forces using a calibrated EMG-driven neuromusculoskeletal model of the knee. One participant fitted with an instrumented total knee replacement walked at a self-selected speed while medial and lateral tibiofemoral contact forces, ground reaction forces, whole-body kinematics, and lower-limb muscle activity were simultaneously measured. The combination of generic and subject-specific knee joint geometry and kinematics resulted in four different OpenSim models used to estimate muscle-tendon lengths and moment arms. The subject-specific geometric model was created from CT scans and the subject-specific knee joint kinematics representing the translation of the tibia relative to the femur was obtained from fluoroscopy. The EMG-driven model was calibrated using one walking trial, but with three different cost functions that tracked the knee flexion/extension moments with and without constraint over the estimated joint contact forces. The calibrated models then predicted the medial and lateral tibiofemoral contact forces for five other different walking trials. The use of subject-specific models with minimization of the peak tibiofemoral contact forces improved the accuracy of medial contact forces by 47% and lateral contact forces by 7%, respectively compared with the use of generic musculoskeletal model. PMID:24074941

  2. Three-dimensional knee joint contact forces during walking in unilateral transtibial amputees.

    PubMed

    Silverman, Anne K; Neptune, Richard R

    2014-08-22

    Individuals with unilateral transtibial amputations have greater prevalence of osteoarthritis in the intact knee joint relative to the residual leg and non-amputees, but the cause of this greater prevalence is unclear. The purpose of this study was to compare knee joint contact forces and the muscles contributing to these forces between amputees and non-amputees during walking using forward dynamics simulations. We predicted that the intact knee contact forces would be higher than those of the residual leg and non-amputees. In the axial and mediolateral directions, the intact and non-amputee legs had greater peak tibio-femoral contact forces and impulses relative to the residual leg. The peak axial contact force was greater in the intact leg relative to the non-amputee leg, but the stance phase impulse was greater in the non-amputee leg. The vasti and hamstrings muscles in early stance and gastrocnemius in late stance were the largest contributors to the joint contact forces in the non-amputee and intact legs. Through dynamic coupling, the soleus and gluteus medius also had large contributions, even though they do not span the knee joint. In the residual leg, the prosthesis had large contributions to the joint forces, similar to the soleus in the intact and non-amputee legs. These results identify the muscles that contribute to knee joint contact forces during transtibial amputee walking and suggest that the peak knee contact forces may be more important than the knee contact impulses in explaining the high prevalence of intact leg osteoarthritis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Shoulder model validation and joint contact forces during wheelchair activities.

    PubMed

    Morrow, Melissa M B; Kaufman, Kenton R; An, Kai-Nan

    2010-09-17

    Chronic shoulder impingement is a common problem for manual wheelchair users. The loading associated with performing manual wheelchair activities of daily living is substantial and often at a high frequency. Musculoskeletal modeling and optimization techniques can be used to estimate the joint contact forces occurring at the shoulder to assess the soft tissue loading during an activity and to possibly identify activities and strategies that place manual wheelchair users at risk for shoulder injuries. The purpose of this study was to validate an upper extremity musculoskeletal model and apply the model to wheelchair activities for analysis of the estimated joint contact forces. Upper extremity kinematics and handrim wheelchair kinetics were measured over three conditions: level propulsion, ramp propulsion, and a weight relief lift. The experimental data were used as input to a subject-specific musculoskeletal model utilizing optimization to predict joint contact forces of the shoulder during all conditions. The model was validated using a mean absolute error calculation. Model results confirmed that ramp propulsion and weight relief lifts place the shoulder under significantly higher joint contact loading than level propulsion. In addition, they exhibit large superior contact forces that could contribute to impingement. This study highlights the potential impingement risk associated with both the ramp and weight relief lift activities. Level propulsion was shown to have a low relative risk of causing injury, but with consideration of the frequency with which propulsion is performed, this observation is not conclusive.

  4. Contact Patterns among High School Students

    PubMed Central

    Fournet, Julie; Barrat, Alain

    2014-01-01

    Face-to-face contacts between individuals contribute to shape social networks and play an important role in determining how infectious diseases can spread within a population. It is thus important to obtain accurate and reliable descriptions of human contact patterns occurring in various day-to-day life contexts. Recent technological advances and the development of wearable sensors able to sense proximity patterns have made it possible to gather data giving access to time-varying contact networks of individuals in specific environments. Here we present and analyze two such data sets describing with high temporal resolution the contact patterns of students in a high school. We define contact matrices describing the contact patterns between students of different classes and show the importance of the class structure. We take advantage of the fact that the two data sets were collected in the same setting during several days in two successive years to perform a longitudinal analysis on two very different timescales. We show the high stability of the contact patterns across days and across years: the statistical distributions of numbers and durations of contacts are the same in different periods, and we observe a very high similarity of the contact matrices measured in different days or different years. The rate of change of the contacts of each individual from one day to the next is also similar in different years. We discuss the interest of the present analysis and data sets for various fields, including in social sciences in order to better understand and model human behavior and interactions in different contexts, and in epidemiology in order to inform models describing the spread of infectious diseases and design targeted containment strategies. PMID:25226026

  5. Taking two to tango: fMRI analysis of improvised joint action with physical contact

    PubMed Central

    Belyk, Michel; Brown, Steven

    2018-01-01

    Many forms of joint action involve physical coupling between the participants, such as when moving a sofa together or dancing a tango. We report the results of a novel two-person functional MRI study in which trained couple dancers engaged in bimanual contact with an experimenter standing next to the bore of the magnet, and in which the two alternated between being the leader and the follower of joint improvised movements. Leading showed a general pattern of self-orientation, being associated with brain areas involved in motor planning, navigation, sequencing, action monitoring, and error correction. In contrast, following showed a far more sensory, externally-oriented pattern, revealing areas involved in somatosensation, proprioception, motion tracking, social cognition, and outcome monitoring. We also had participants perform a “mutual” condition in which the movement patterns were pre-learned and the roles were symmetric, thereby minimizing any tendency toward either leading or following. The mutual condition showed greater activity in brain areas involved in mentalizing and social reward than did leading or following. Finally, the analysis of improvisation revealed the dual importance of motor-planning and working-memory areas. We discuss these results in terms of theories of both joint action and improvisation. PMID:29324862

  6. Contact pressure in the facet joint during sagittal bending of the cadaveric cervical spine.

    PubMed

    Jaumard, Nicolas V; Bauman, Joel A; Weisshaar, Christine L; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A

    2011-07-01

    The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local

  7. Early rheumatoid disease. II. Patterns of joint involvement.

    PubMed Central

    Fleming, A; Benn, R T; Corbett, M; Wood, P H

    1976-01-01

    Data from the first research clinic visit (Fleming and others, 1976) have been subjected to factor analysis to identify early patterns of joint involvement. Nine patterns emerged. Two patterns, if present early, were found to have prognostic significance. An eventually more severe disease was associated with a pattern of large joint involvement (shoulder, elbow, wrist, knee) and a pattern based on metatarsophalangeal joints I and III. PMID:970995

  8. Changes of contact pressure and area in patellofemoral joint after different meniscectomies.

    PubMed

    Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni

    2012-05-01

    We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.

  9. A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints

    PubMed Central

    Chyr, Anthony; Qiu, Mingfeng; Speltz, Jared; Jacobsen, Ronald L.; Sanders, Anthony P.; Raeymaekers, Bart

    2014-01-01

    More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily as a result of polyethylene wear and wear debris incited disease. The current engineering paradigm to increase the longevity of prosthetic hip joints is to improve the mechanical properties of the polyethylene component, and to manufacture ultra-smooth articulating surfaces. In contrast, we show that adding a patterned microtexture to the ultra-smooth CoCr femoral head reduces friction when articulating with the polyethylene acetabular liner. The microtexture increases the load-carrying capacity and the thickness of the joint lubricant film, which reduces contact between the articulating surfaces. As a result, friction and wear is reduced. We have used a lubrication model to design the geometry of the patterned microtexture, and experimentally demonstrate reduced friction for the microtextured compared to conventional smooth surrogate prosthetic hip joints. PMID:25013240

  10. Walking patterns and hip contact forces in patients with hip dysplasia.

    PubMed

    Skalshøi, Ole; Iversen, Christian Hauskov; Nielsen, Dennis Brandborg; Jacobsen, Julie; Mechlenburg, Inger; Søballe, Kjeld; Sørensen, Henrik

    2015-10-01

    Several studies have investigated walking characteristics in hip dysplasia patients, but so far none have described all hip rotational degrees of freedom during the whole gait cycle. This descriptive study reports 3D joint angles and torques, and furthermore extends previous studies with muscle and joint contact forces in 32 hip dysplasia patients and 32 matching controls. 3D motion capture data from walking and standing trials were analysed. Hip, knee, ankle and pelvis angles were calculated with inverse kinematics for both standing and walking trials. Hip, knee and ankle torques were calculated with inverse dynamics, while hip muscle and joint contact forces were calculated with static optimisation for the walking trials. No differences were found between the two groups while standing. While walking, patients showed decreased hip extension, increased ankle pronation and increased hip abduction and external rotation torques. Furthermore, hip muscle forces were generally lower and shifted to more posteriorly situated muscles, while the hip joint contact force was lower and directed more superiorly. During walking, patients showed lower and more superiorly directed hip joint contact force, which might alleviate pain from an antero-superiorly degenerated joint. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    PubMed

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  12. A method to investigate the biomechanical alterations in Perthes' disease by hip joint contact modeling.

    PubMed

    Salmingo, Remel Alingalan; Skytte, Tina Lercke; Traberg, Marie Sand; Mikkelsen, Lars Pilgaard; Henneberg, Kaj-Åge; Wong, Christian

    2017-01-01

    Perthes' disease is a destructive hip joint disorder characterized by malformation of the femoral head in young children. While the morphological changes have been widely studied, the biomechanical effects of these changes still need to be further elucidated. The objective of this study was to develop a method to investigate the biomechanical alterations in Perthes' disease by finite element (FE) contact modeling using MRI. The MRI data of a unilateral Perthes' case was obtained to develop the three-dimensional FE model of the hip joint. The stress and contact pressure patterns in the unaffected hip were well distributed. Elevated concentrations of stress and contact pressure were found in the Perthes' hip. The highest femoral cartilage von Mises stress 3.9 MPa and contact pressure 5.3 MPa were found in the Perthes' hip, whereas 2.4 MPa and 4.9 MPa in the healthy hip, respectively. The healthy bone in the femoral head of the Perthes' hip carries additional loads as indicated by the increase of stress levels around the necrotic-healthy bone interface. Identifying the biomechanical changes, such as the location of stress and contact pressure concentrations, is a prerequisite for the preoperative planning to obtain stress relief for the highly stressed areas in the malformed hip. This single-patient study demonstrated that the biomechanical alterations in Perthes' disease can be evaluated individually by patient-specific finite element contact modeling using MRI. A multi-patient study is required to test the strength of the proposed method as a pre-surgery planning tool.

  13. Prediction of Knee Joint Contact Forces From External Measures Using Principal Component Prediction and Reconstruction.

    PubMed

    Saliba, Christopher M; Clouthier, Allison L; Brandon, Scott C E; Rainbow, Michael J; Deluzio, Kevin J

    2018-05-29

    Abnormal loading of the knee joint contributes to the pathogenesis of knee osteoarthritis. Gait retraining is a non-invasive intervention that aims to reduce knee loads by providing audible, visual, or haptic feedback of gait parameters. The computational expense of joint contact force prediction has limited real-time feedback to surrogate measures of the contact force, such as the knee adduction moment. We developed a method to predict knee joint contact forces using motion analysis and a statistical regression model that can be implemented in near real-time. Gait waveform variables were deconstructed using principal component analysis and a linear regression was used to predict the principal component scores of the contact force waveforms. Knee joint contact force waveforms were reconstructed using the predicted scores. We tested our method using a heterogenous population of asymptomatic controls and subjects with knee osteoarthritis. The reconstructed contact force waveforms had mean (SD) RMS differences of 0.17 (0.05) bodyweight compared to the contact forces predicted by a musculoskeletal model. Our method successfully predicted subject-specific shape features of contact force waveforms and is a potentially powerful tool in biofeedback and clinical gait analysis.

  14. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Movement coordination patterns between the foot joints during walking.

    PubMed

    Arnold, John B; Caravaggi, Paolo; Fraysse, François; Thewlis, Dominic; Leardini, Alberto

    2017-01-01

    In 3D gait analysis, kinematics of the foot joints are usually reported via isolated time histories of joint rotations and no information is provided on the relationship between rotations at different joints. The aim of this study was to identify movement coordination patterns in the foot during walking by expanding an existing vector coding technique according to an established multi-segment foot and ankle model. A graphical representation is also described to summarise the coordination patterns of joint rotations across multiple patients. Three-dimensional multi-segment foot kinematics were recorded in 13 adults during walking. A modified vector coding technique was used to identify coordination patterns between foot joints involving calcaneus, midfoot, metatarsus and hallux segments. According to the type and direction of joints rotations, these were classified as in-phase (same direction), anti-phase (opposite directions), proximal or distal joint dominant. In early stance, 51 to 75% of walking trials showed proximal-phase coordination between foot joints comprising the calcaneus, midfoot and metatarsus. In-phase coordination was more prominent in late stance, reflecting synergy in the simultaneous inversion occurring at multiple foot joints. Conversely, a distal-phase coordination pattern was identified for sagittal plane motion of the ankle relative to the midtarsal joint, highlighting the critical role of arch shortening to locomotor function in push-off. This study has identified coordination patterns between movement of the calcaneus, midfoot, metatarsus and hallux by expanding an existing vector cording technique for assessing and classifying coordination patterns of foot joints rotations during walking. This approach provides a different perspective in the analysis of multi-segment foot kinematics, and may be used for the objective quantification of the alterations in foot joint coordination patterns due to lower limb pathologies or following injuries.

  16. Effect of Complete Syndesmotic Disruption and Deltoid Injuries and Different Reduction Methods on Ankle Joint Contact Mechanics.

    PubMed

    LaMothe, Jeremy; Baxter, Josh R; Gilbert, Susannah; Murphy, Conor I; Karnovsky, Sydney C; Drakos, Mark C

    2017-06-01

    Syndesmotic injuries can be associated with poor patient outcomes and posttraumatic ankle arthritis, particularly in the case of malreduction. However, ankle joint contact mechanics following a syndesmotic injury and reduction remains poorly understood. The purpose of this study was to characterize the effects of a syndesmotic injury and reduction techniques on ankle joint contact mechanics in a biomechanical model. Ten cadaveric whole lower leg specimens with undisturbed proximal tibiofibular joints were prepared and tested in this study. Contact area, contact force, and peak contact pressure were measured in the ankle joint during simulated standing in the intact, injured, and 3 reduction conditions: screw fixation with a clamp, screw fixation without a clamp (thumb technique), and a suture-button construct. Differences in these ankle contact parameters were detected between conditions using repeated-measures analysis of variance. Syndesmotic disruption decreased tibial plafond contact area and force. Syndesmotic reduction did not restore ankle loading mechanics to values measured in the intact condition. Reduction with the thumb technique was able to restore significantly more joint contact area and force than the reduction clamp or suture-button construct. Syndesmotic disruption decreased joint contact area and force. Although the thumb technique performed significantly better than the reduction clamp and suture-button construct, syndesmotic reduction did not restore contact mechanics to intact levels. Decreased contact area and force with disruption imply that other structures are likely receiving more loads (eg, medial and lateral gutters), which may have clinical implications such as the development of posttraumatic arthritis.

  17. Prediction of elbow joint contact mechanics in the multibody framework.

    PubMed

    Rahman, Munsur; Cil, Akin; Stylianou, Antonis P

    2016-03-01

    Computational multibody musculoskeletal models of the elbow joint that are capable of simultaneous and accurate predictions of muscle and ligament forces, along with cartilage contact mechanics can be immensely useful in clinical practice. As a step towards producing a musculoskeletal model that includes the interaction between cartilage and muscle loading, the goal of this study was to develop subject-specific multibody models of the elbow joint with discretized humerus cartilage representation interacting with the radius and ulna cartilages through deformable contacts. The contact parameters for the compliant contact law were derived using simplified elastic foundation contact theory. The models were then validated by placing the model in a virtual mechanical tester for flexion-extension motion similar to a cadaver experiment, and the resulting kinematics were compared. Two cadaveric upper limbs were used in this study. The humeral heads were subjected to axial motion in a mechanical tester and the resulting kinematics from three bones were recorded for model validation. The maximum RMS error between the predicted and measured kinematics during the complete testing cycle was 2.7 mm medial-lateral translation and 9.7° varus-valgus rotation of radius relative to humerus (for elbow 2). After model validation, a lateral ulnar collateral ligament (LUCL) deficient condition was simulated and, contact pressures and kinematics were compared to the intact elbow model. A noticeable difference in kinematics, contact area, and contact pressure were observed for LUCL deficient condition. LUCL deficiency induced higher internal rotations for both the radius and ulna during flexion and an associated medial shift of the articular contact area. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Effect of hoof angle on joint contact area in the equine metacarpophalangeal joint following simulated impact loading ex vivo.

    PubMed

    McCarty, C A; Thomason, J J; Gordon, K; Hurtig, M; Bignell, W

    2015-11-01

    To add to the existing data on impact loading of the metacarpophalangeal (MCP) joint as a precursor to assessing the potential role of impact in joint disease. To examine the effect of impact loading on contact areas of the first phalanx (P1) and proximal sesamoids (PS) with the third metacarpal (McIII) under 3 hoof-strike conditions (toe-first, flat, heel-first). Randomised, repeated controlled experiment using cadaver material. Eight cadaver limbs were subjected to randomised, repeated controlled trials where the hoof was struck by a pendulum impact machine (impact velocity 3.55 m/s) under 3 strike conditions. Data from pressure sensitive film placed over medial and lateral McIII condyles and lateromedially across the dorsal aspect of McIII were quantified: total areas of P1 and PS contact (cm(2) ) at maximum recorded pressure; centroid locations of contact areas relative to the sagittal ridge (cm) and transverse ridge (cm) and dispersion of pixels (cm(4) ) for each McIII condyle (medial/lateral). The effect of the strike conditions on each variable were statistically tested using repeated-measures ANOVA (α = 0.05). Contact area between P1 and McIII condyles fell in well-defined areas bounded by the sagittal and transverse ridge, contact areas from PS were smaller and widely dispersed across McIII palmar border. Ratio of contact area of P1 to PS was 2.83 (P<0001). Hoof strike had no significant effect on contact area (P>0.54) CONCLUSIONS: Contact at impact (primarily from P1 and distally situated on McIII), contrasts with contact areas at midstance from both P1 and PS, symmetrically placed. Under impact, the greatest contact area was on the dorsal aspect of the medial condyle and coincides with the area subjected to the greatest increase in subchondral bone stiffening in joint disease. © 2014 EVJ Ltd.

  19. Respiratory pattern changes during costovertebral joint movement.

    PubMed

    Shannon, R

    1980-05-01

    Experiments were conducted to determine if costovertebral joint manipulation (CVJM) could influence the respiratory pattern. Phrenic efferent activity (PA) was monitored in dogs that were anesthetized with Dial-urethane, vagotomized, paralyzed, and artificially ventilated. Ribs 6-10 (bilaterally) were cut and separated from ribs 5-11. Branches of thoracic nerves 5-11 were cut, leaving only the joint nerve supply intact. Manual joint movement in an inspiratory or expiratory direction had an inhibitory effect on PA. Sustained displacement of the ribs could inhibit PA for a duration equal to numerous respiratory cycles. CVJM in synchrony with PA resulted in an increased respiratory rate. The inspiratory inhibitory effect of joint receptor stimulation was elicited with manual chest compression in vagotomized spontaneously breathing dogs, but not with artificial lung inflation or deflation. It is concluded that the effect of CVJM on the respiratory pattern is due to stimulation of joint mechanoreceptors, and that they exert their influence in part via the medullary-pontine rhythm generator.

  20. Analysis of the Effects of Normal Walking on Ankle Joint Contact Characteristics After Acute Inversion Ankle Sprain.

    PubMed

    Bae, Ji Yong; Park, Kyung Soon; Seon, Jong Keun; Jeon, Insu

    2015-12-01

    To show the causal relationship between normal walking after various lateral ankle ligament (LAL) injuries caused by acute inversion ankle sprains and alterations in ankle joint contact characteristics, finite element simulations of normal walking were carried out using an intact ankle joint model and LAL injury models. A walking experiment using a volunteer with a normal ankle joint was performed to obtain the boundary conditions for the simulations and to support the appropriateness of the simulation results. Contact pressure and strain on the talus articular cartilage and anteroposterior and mediolateral translations of the talus were calculated. Ankles with ruptured anterior talofibular ligaments (ATFLs) had a higher likelihood of experiencing increased ankle joint contact pressures, strains and translations than ATFL-deficient ankles. In particular, ankles with ruptured ATFL + calcaneofibular ligaments and all ruptured ankles had a similar likelihood as the ATFL-ruptured ankles. The push off stance phase was the most likely situation for increased ankle joint contact pressures, strains and translations in LAL-injured ankles.

  1. The influence of patellofemoral joint contact geometry on the modeling of three dimensional patellofemoral joint forces.

    PubMed

    Powers, Christopher M; Chen, Yu-Jen; Scher, Irving; Lee, Thay Q

    2006-01-01

    The purpose of this study was to determine the influence of patellofemoral joint contact geometry on the modeling of three-dimensional patellofemoral joint forces. To achieve this goal, patellofemoral joint reaction forces (PFJRFs) that were measured from an in-vitro cadaveric set-up were compared to PFJRFs estimated from a computer model that did not consider patellofemoral joint contact geometry. Ten cadaver knees were used in this study. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were accomplished using a pulley system and weights. The force in the patellar ligament was obtained using a buckle transducer. To quantify the magnitude and direction of the PFJRF, a six-axis load cell was incorporated into the femoral fixation system so that a rigid body assumption could be made. PFJRF data were obtained at 0 degrees , 20 degrees , 40 degrees and 60 degrees of knee flexion. Following in vitro testing, SIMM modeling software was used to develop computational models based on the three-dimensional coordinates (Microscribe digitizer) of individual muscle and patellar ligament force vectors obtained from the cadaver knees. The overall magnitude of the PFJRF estimated from the computer generated models closely matched the direct measurements from the in vitro set-up (Pearson's correlation coefficient, R(2)=0.91, p<0.001). Although the computational model accurately estimated the posteriorly directed forces acting on the joint, some discrepancies were noted in the forces acting in the superior and lateral directions. These differences however, were relatively small when expressed as a total of the overall PFJRF magnitude.

  2. Development of a computational technique to measure cartilage contact area.

    PubMed

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Independent effects of step length and foot strike pattern on tibiofemoral joint forces during running.

    PubMed

    Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D

    2017-10-01

    The purpose of this study was to examine the effects of step length and foot strike pattern along with their interaction on tibiofemoral joint (TFJ) and medial compartment TFJ kinetics during running. Nineteen participants ran with a rear foot strike pattern at their preferred speed using a short (-10%), preferred, and long (+10%) step length. These step length conditions were then repeated using a forefoot strike pattern. Regardless of foot strike pattern, a 10% shorter step length resulted in decreased peak contact force, force impulse per step, force impulse per kilometre, and average loading rate at the TFJ and medial compartment, while a 10% increased step length had the opposite effects (all P < 0.05). A forefoot strike pattern significantly lowered TFJ and medial compartment TFJ average loading rates compared with a rear foot strike pattern (both <0.05) but did not change TFJ or medial compartment peak force, force impulse per step, or force impulse per km. The combination of a shorter step length and forefoot strike pattern produced the greatest reduction in peak medial compartment contact force (P < 0.05). Knowledge of these running modification effects may be relevant to the management or prevention of TFJ injury or pathology among runners.

  4. Ankle Joint Contact Loads and Displacement With Progressive Syndesmotic Injury.

    PubMed

    Hunt, Kenneth J; Goeb, Yannick; Behn, Anthony W; Criswell, Braden; Chou, Loretta

    2015-09-01

    Ligamentous injuries to the distal tibiofibular syndesmosis are predictive of long-term ankle dysfunction. Mild and moderate syndesmotic injuries are difficult to stratify, and the impact of syndesmosis injury on the magnitude and distribution of forces within the ankle joint during athletic activities is unknown. Eight below-knee cadaveric specimens were tested in the intact state and after sequential sectioning of the following ligaments: anterior-inferior tibiofibular, anterior deltoid (1 cm), interosseous/transverse (IOL/TL), posterior-inferior tibiofibular, and whole deltoid. In each condition, specimens were loaded in axial compression to 700 N and then externally rotated to 20 N·m torque. During axial loading and external rotation, both the fibula and the talus rotated significantly after each ligament sectioning as compared to the intact condition. After IOL/TL release, a significant increase in posterior translation of the fibula was observed, although no syndesmotic widening was observed. Mean tibiotalar contact pressure increased significantly after IOL/TL release, and the center of pressure shifted posterolaterally, relative to more stable conditions, after IOL/TL release. There were significant increases in mean contact pressure and peak pressure along with a reduction in contact area with axial loading and external rotation as compared to axial loading alone for all 5 conditions. Significant increases in tibiotalar contact pressures occur when external rotation stresses are added to axial loading. Moderate and severe injuries are associated with a significant increase in mean contact pressure combined with a shift in the center of pressure and rotation of the fibula and talus. Considerable changes in ankle joint kinematics and contact mechanics may explain why moderate syndesmosis injuries take longer to heal and are more likely to develop long-term dysfunction and, potentially, ankle arthritis. © The Author(s) 2015.

  5. Tibiofemoral joint contact area and pressure after single- and double-bundle anterior cruciate ligament reconstruction.

    PubMed

    Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H

    2009-01-01

    The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.

  6. Dynamic simulation of knee-joint loading during gait using force-feedback control and surrogate contact modelling.

    PubMed

    Walter, Jonathan P; Pandy, Marcus G

    2017-10-01

    The aim of this study was to perform multi-body, muscle-driven, forward-dynamics simulations of human gait using a 6-degree-of-freedom (6-DOF) model of the knee in tandem with a surrogate model of articular contact and force control. A forward-dynamics simulation incorporating position, velocity and contact force-feedback control (FFC) was used to track full-body motion capture data recorded for multiple trials of level walking and stair descent performed by two individuals with instrumented knee implants. Tibiofemoral contact force errors for FFC were compared against those obtained from a standard computed muscle control algorithm (CMC) with a 6-DOF knee contact model (CMC6); CMC with a 1-DOF translating hinge-knee model (CMC1); and static optimization with a 1-DOF translating hinge-knee model (SO). Tibiofemoral joint loads predicted by FFC and CMC6 were comparable for level walking, however FFC produced more accurate results for stair descent. SO yielded reasonable predictions of joint contact loading for level walking but significant differences between model and experiment were observed for stair descent. CMC1 produced the least accurate predictions of tibiofemoral contact loads for both tasks. Our findings suggest that reliable estimates of knee-joint loading may be obtained by incorporating position, velocity and force-feedback control with a multi-DOF model of joint contact in a forward-dynamics simulation of gait. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Thoracic costotransverse joint pain patterns: a study in normal volunteers.

    PubMed

    Young, Brian A; Gill, Howard E; Wainner, Robert S; Flynn, Timothy W

    2008-10-15

    Pain referral patterns of asymptomatic costotransverse joints have not been established. The objective of this study was to determine the pain referral patterns of asymptomatic costotransverse joints via provocative intra-articular injection. Eight asymptomatic male volunteers received a combined total of 21 intra-articular costotransverse joint injections. Fluoroscopic imaging was used to identify and isolate each costotransverse joint and guide placement of a 25 gauge, 2.5 inch spinal needle into the costotransverse joint. Following contrast medium injection, the quality, intensity, and distribution of the resultant pain produced were recorded. Of the 21 costotransverse joint injections, 16 (76%) were classified as being intra-articular via arthrograms taken at the time of injection, and 14 of these injections produced a pain sensation distinctly different from that of needle placement. Average pain produced was 3.3/10 on a 0-10 verbal pain scale. Pain was described generally as a deep, dull ache, and pressure sensation. Pain patterns were located superficial to the injected joint, with only the right T2 injections showing referred pain 2 segments cranially and caudally. No chest wall, upper extremity or pseudovisceral pains were reported. This study provides preliminary data of the pain referral patterns of costotransverse joints. Further research is needed to compare these findings with those elicited from symptomatic subjects.

  8. A model to explain joint patterns found in ignimbrite deposits

    NASA Astrophysics Data System (ADS)

    Tibaldi, A.; Bonali, F. L.

    2018-03-01

    The study of fracture systems is of paramount importance for economic applications, such as CO2 storage in rock successions, geothermal and hydrocarbon exploration and exploitation, and also for a better knowledge of seismogenic fault formation. Understanding the origin of joints can be useful for tectonic studies and for a geotechnical characterisation of rock masses. Here, we illustrate a joint pattern discovered in ignimbrite deposits of South America, which can be confused with conjugate tectonic joint sets but which have another origin. The pattern is probably common, but recognisable only in plan view and before tectonic deformation obscures and overprints it. Key sites have been mostly studied by field surveys in Bolivia and Chile. The pattern is represented by hundreds-of-meters up to kilometre-long swarms of master joints, which show circular to semi-circular geometries and intersections that have "X" and "Y" patterns. Inside each swarm, joints are systematic, rectilinear or curvilinear in plan view, and as much as 900 m long. In section view, they are from sub-vertical to vertical and do not affect the underlying deposits. Joints with different orientation mostly interrupt each other, suggesting they have the same age. This joint architecture is here interpreted as resulting from differential contraction after emplacement of the ignimbrite deposit above a complex topography. The set of the joint pattern that has suitable orientation with respect to tectonic stresses may act to nucleate faults.

  9. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  10. Joint-bounded crescentic scars formed by subglacial clast-bed contact forces: Implications for bedrock failure beneath glaciers

    NASA Astrophysics Data System (ADS)

    Krabbendam, M.; Bradwell, T.; Everest, J. D.; Eyles, N.

    2017-08-01

    Glaciers and ice sheets are important agents of bedrock erosion, yet the precise processes of bedrock failure beneath glacier ice are incompletely known. Subglacially formed erosional crescentic markings (crescentic gouges, lunate fractures) on bedrock surfaces occur locally in glaciated areas and comprise a conchoidal fracture dipping down-ice and a steep fracture that faces up-ice. Here we report morphologically distinct crescentic scars that are closely associated with preexisting joints, termed here joint-bounded crescentic scars. These hitherto unreported features are ca. 50-200 mm deep and involve considerably more rock removal than previously described crescentic markings. The joint-bounded crescentic scars were found on abraded rhyolite surfaces recently exposed (< 20 years) beneath a retreating glacier in Iceland, as well as on glacially sculpted Precambrian gneisses in NW Scotland and various Precambrian rocks in Ontario, glaciated during the Late Pleistocene. We suggest a common formation mechanism for these contemporary and relict features, whereby a boulder embedded in basal ice produces a continuously migrating clast-bed contact force as it is dragged over the hard (bedrock) bed. As the ice-embedded boulder approaches a preexisting joint in the bedrock, stress concentrations build up in the bed that exceed the intact rock strength, resulting in conchoidal fracturing and detachment of a crescentic wedge-shaped rock fragment. Subsequent removal of the rock fragment probably involves further fracturing or crushing (comminution) under high contact forces. Formation of joint-bounded crescentic scars is favoured by large boulders at the base of the ice, high basal melting rates, and the presence of preexisting subvertical joints in the bedrock bed. We infer that the relative scarcity of crescentic markings in general on deglaciated surfaces shows that fracturing of intact bedrock below ice is difficult, but that preexisting weaknesses such as joints greatly

  11. Biofeedback for Gait Retraining Based on Real-Time Estimation of Tibiofemoral Joint Contact Forces.

    PubMed

    Pizzolato, Claudio; Reggiani, Monica; Saxby, David J; Ceseracciu, Elena; Modenese, Luca; Lloyd, David G

    2017-09-01

    Biofeedback assisted rehabilitation and intervention technologies have the potential to modify clinically relevant biomechanics. Gait retraining has been used to reduce the knee adduction moment, a surrogate of medial tibiofemoral joint loading often used in knee osteoarthritis research. In this paper, we present an electromyogram-driven neuromusculoskeletal model of the lower-limb to estimate, in real-time, the tibiofemoral joint loads. The model included 34 musculotendon units spanning the hip, knee, and ankle joints. Full-body inverse kinematics, inverse dynamics, and musculotendon kinematics were solved in real-time from motion capture and force plate data to estimate the knee medial tibiofemoral contact force (MTFF). We analyzed five healthy subjects while they were walking on an instrumented treadmill with visual biofeedback of their MTFF. Each subject was asked to modify their gait in order to vary the magnitude of their MTFF. All subjects were able to increase their MTFF, whereas only three subjects could decrease it, and only after receiving verbal suggestions about possible gait modification strategies. Results indicate the important role of knee muscle activation patterns in modulating the MTFF. While this paper focused on the knee, the technology can be extended to examine the musculoskeletal tissue loads at different sites of the human body.

  12. Influence of weak hip abductor muscles on joint contact forces during normal walking: probabilistic modeling analysis.

    PubMed

    Valente, Giordano; Taddei, Fulvia; Jonkers, Ilse

    2013-09-03

    The weakness of hip abductor muscles is related to lower-limb joint osteoarthritis, and joint overloading may increase the risk for disease progression. The relationship between muscle strength, structural joint deterioration and joint loading makes the latter an important parameter in the study of onset and follow-up of the disease. Since the relationship between hip abductor weakness and joint loading still remains an open question, the purpose of this study was to adopt a probabilistic modeling approach to give insights into how the weakness of hip abductor muscles, in the extent to which normal gait could be unaltered, affects ipsilateral joint contact forces. A generic musculoskeletal model was scaled to each healthy subject included in the study, and the maximum force-generating capacity of each hip abductor muscle in the model was perturbed to evaluate how all physiologically possible configurations of hip abductor weakness affected the joint contact forces during walking. In general, the muscular system was able to compensate for abductor weakness. The reduced force-generating capacity of the abductor muscles affected joint contact forces to a mild extent, with 50th percentile mean differences up to 0.5 BW (maximum 1.7 BW). There were greater increases in the peak knee joint loads than in loads at the hip or ankle. Gluteus medius, particularly the anterior compartment, was the abductor muscle with the most influence on hip and knee loads. Further studies should assess if these increases in joint loading may affect initiation and progression of osteoarthritis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Effect of radial head implant shape on joint contact area and location during static loading.

    PubMed

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Knee joint contact mechanics during downhill gait and its relationship with varus/valgus motion and muscle strength in patients with knee osteoarthritis.

    PubMed

    Farrokhi, Shawn; Voycheck, Carrie A; Gustafson, Jonathan A; Fitzgerald, G Kelley; Tashman, Scott

    2016-01-01

    The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p < 0.02) and greater heel-strike joint contact point velocities (p < 0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p = 0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p < 0.01) and greater quadriceps and hip abductor muscle weakness (p = 0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p < 0.04) but not with quadriceps or hip abductor strength. Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength.

  15. Knee Joint Contact Mechanics during Downhill Gait and its Relationship with Varus/Valgus Motion and Muscle Strength in Patients with Knee Osteoarthritis

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Gustafson, Jonathan A.; Fitzgerald, G. Kelley; Tashman, Scott

    2015-01-01

    Objective The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Methods Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Group differences in contact mechanics and frontal-plane motion excursions were compared using analysis of covariance with adjustments for body mass index. Differences in strength were compared using independent sample t-tests. Additionally, linear associations between contact mechanics with frontal-plane knee motion and muscle strength were evaluated using Pearson's correlation coefficients. Results Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p<0.02) and greater heel-strike joint contact point velocities (p<0.05) for the medial and lateral compartments compared to the control group. The peak medial/lateral joint contact point velocity of the medial compartment was also greater for patients with knee OA compared to their control counterparts (p=0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p<0.01) and greater quadriceps and hip abductor muscle weakness (p=0.03). In general, increased joint contact point excursions and velocities in patients with knee OA were linearly associated with greater frontal-plane varus motion excursions (p<0.04) but not with quadriceps or hip abductor strength. Conclusion Altered contact mechanics in patients with knee OA may be related to compromised frontal-plane joint stability but not with

  16. Vocal fold contact patterns based on normal modes of vibration.

    PubMed

    Smith, Simeon L; Titze, Ingo R

    2018-05-17

    The fluid-structure interaction and energy transfer from respiratory airflow to self-sustained vocal fold oscillation continues to be a topic of interest in vocal fold research. Vocal fold vibration is driven by pressures on the vocal fold surface, which are determined by the shape of the glottis and the contact between vocal folds. Characterization of three-dimensional glottal shapes and contact patterns can lead to increased understanding of normal and abnormal physiology of the voice, as well as to development of improved vocal fold models, but a large inventory of shapes has not been directly studied previously. This study aimed to take an initial step toward characterizing vocal fold contact patterns systematically. Vocal fold motion and contact was modeled based on normal mode vibration, as it has been shown that vocal fold vibration can be almost entirely described by only the few lowest order vibrational modes. Symmetric and asymmetric combinations of the four lowest normal modes of vibration were superimposed on left and right vocal fold medial surfaces, for each of three prephonatory glottal configurations, according to a surface wave approach. Contact patterns were generated from the interaction of modal shapes at 16 normalized phases during the vibratory cycle. Eight major contact patterns were identified and characterized by the shape of the flow channel, with the following descriptors assigned: convergent, divergent, convergent-divergent, uniform, split, merged, island, and multichannel. Each of the contact patterns and its variation are described, and future work and applications are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    PubMed

    Kern, Andrew M; Anderson, Donald D

    2015-09-18

    Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promising agreement with PTOA development was seen, the inherent complexities of contact FEA limited the numbers of subjects that could be analyzed. Discrete element analysis (DEA) is a simplified methodology for contact stress computation, which idealizes contact surfaces as a bed of independent linear springs. In this study, DEA was explored as an expedited alternative to FEA contact stress exposure computation. DEA was compared to FEA using results from a previously completed validation study of two cadaveric human ankles, as well as a previous study of post-operative contact stress exposure in 11 patients with tibial plafond fracture. DEA-computed maximum contact stresses were within 19% of those experimentally measured, with 90% of the contact area having computed contact stress values within 1MPa of those measured. In the 11 fractured ankles, maximum contact stress and contact area differences between DEA and FEA were 0.85 ± 0.64 MPa and 22.5 ± 11.5mm(2). As a predictive measure for PTOA development, both DEA and FEA had 100% concordance with presence of OA (KL grade ≥ 2) and >95% concordance with KL grade at 2 years. These results support DEA as a reasonable alternative to FEA for computing contact stress exposures following surgical reduction of a tibial plafond fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Lower-Limb Joint Coordination Pattern in Obese Subjects

    PubMed Central

    Ranavolo, Alberto; Donini, Lorenzo M.; Mari, Silvia; Serrao, Mariano; Silvetti, Alessio; Iavicoli, Sergio; Cava, Edda; Asprino, Rosa; Pinto, Alessandro; Draicchio, Francesco

    2013-01-01

    The coordinative pattern is an important feature of locomotion that has been studied in a number of pathologies. It has been observed that adaptive changes in coordination patterns are due to both external and internal constraints. Obesity is characterized by the presence of excess mass at pelvis and lower-limb areas, causing mechanical constraints that central nervous system could manage modifying the physiological interjoint coupling relationships. Since an altered coordination pattern may induce joint diseases and falls risk, the aim of this study was to analyze whether and how coordination during walking is affected by obesity. We evaluated interjoint coordination during walking in 25 obese subjects as well as in a control group. The time-distance parameters and joint kinematics were also measured. When compared with the control group, obese people displayed a substantial similarity in joint kinematic parameters and some differences in the time-distance and in the coupling parameters. Obese subjects revealed higher values in stride-to-stride intrasubjects variability in interjoint coupling parameters, whereas the coordinative mean pattern was unaltered. The increased variability in the coupling parameters is associated with an increased risk of falls and thus should be taken into account when designing treatments aimed at restoring a normal locomotion pattern. PMID:23484078

  19. A computational framework for simultaneous estimation of muscle and joint contact forces and body motion using optimization and surrogate modeling.

    PubMed

    Eskinazi, Ilan; Fregly, Benjamin J

    2018-04-01

    Concurrent estimation of muscle activations, joint contact forces, and joint kinematics by means of gradient-based optimization of musculoskeletal models is hindered by computationally expensive and non-smooth joint contact and muscle wrapping algorithms. We present a framework that simultaneously speeds up computation and removes sources of non-smoothness from muscle force optimizations using a combination of parallelization and surrogate modeling, with special emphasis on a novel method for modeling joint contact as a surrogate model of a static analysis. The approach allows one to efficiently introduce elastic joint contact models within static and dynamic optimizations of human motion. We demonstrate the approach by performing two optimizations, one static and one dynamic, using a pelvis-leg musculoskeletal model undergoing a gait cycle. We observed convergence on the order of seconds for a static optimization time frame and on the order of minutes for an entire dynamic optimization. The presented framework may facilitate model-based efforts to predict how planned surgical or rehabilitation interventions will affect post-treatment joint and muscle function. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Taming contact line instability for pattern formation

    PubMed Central

    Deblais, A.; Harich, R.; Colin, A.; Kellay, H.

    2016-01-01

    Coating surfaces with different fluids is prone to instability producing inhomogeneous films and patterns. The contact line between the coating fluid and the surface to be coated is host to different instabilities, limiting the use of a variety of coating techniques. Here we take advantage of the instability of a receding contact line towards cusp and droplet formation to produce linear patterns of variable spacings. We stabilize the instability of the cusps towards droplet formation by using polymer solutions that inhibit this secondary instability and give rise to long slender cylindrical filaments. We vary the speed of deposition to change the spacing between these filaments. The combination of the two gives rise to linear patterns into which different colloidal particles can be embedded, long DNA molecules can be stretched and particles filtered by size. The technique is therefore suitable to prepare anisotropic structures with variable properties. PMID:27506626

  1. Taming contact line instability for pattern formation.

    PubMed

    Deblais, A; Harich, R; Colin, A; Kellay, H

    2016-08-10

    Coating surfaces with different fluids is prone to instability producing inhomogeneous films and patterns. The contact line between the coating fluid and the surface to be coated is host to different instabilities, limiting the use of a variety of coating techniques. Here we take advantage of the instability of a receding contact line towards cusp and droplet formation to produce linear patterns of variable spacings. We stabilize the instability of the cusps towards droplet formation by using polymer solutions that inhibit this secondary instability and give rise to long slender cylindrical filaments. We vary the speed of deposition to change the spacing between these filaments. The combination of the two gives rise to linear patterns into which different colloidal particles can be embedded, long DNA molecules can be stretched and particles filtered by size. The technique is therefore suitable to prepare anisotropic structures with variable properties.

  2. Labral reconstruction with iliotibial band autografts and semitendinosus allografts improves hip joint contact area and contact pressure: an in vitro analysis.

    PubMed

    Lee, Simon; Wuerz, Thomas H; Shewman, Elizabeth; McCormick, Frank M; Salata, Michael J; Philippon, Marc J; Nho, Shane J

    2015-01-01

    Labral reconstruction using iliotibial band (ITB) autografts and semitendinosus (Semi-T) allografts has recently been described in cases of labral deficiency. To characterize the joint biomechanics with a labrum-intact, labrum-deficient, and labrum-reconstructed acetabulum in a hip cadaveric model. The hypothesis was that labral resection would decrease contact area, increase contact pressure, and increase peak force, while subsequent labral reconstruction with ITB autografts or Semi-T allografts would restore these values toward the native intact labral state. Controlled laboratory study. Ten fresh-frozen human cadaveric hips were analyzed utilizing thin-film piezoresistive load sensors to measure contact area, contact pressure, and peak force (1) with the native intact labrum, (2) after segmental labral resection, and (3) after graft labral reconstruction with either ITB autografts or Semi-T allografts. Each specimen was examined at 20° of extension and 60° of flexion. Statistical analysis was conducted through 1-way analysis of variance with post hoc Games-Howell tests. For the ITB group, labral resection significantly decreased contact area (at 20°: 73.2%±5.38%, P=.0010; at 60°: 78.5%±6.93%, P=.0063) and increased contact pressure (at 20°: 106.7%±4.15%, P=.0387; at 60°: 103.9%±1.15%, P=.0428). In addition, ITB reconstruction improved contact area (at 20°: 87.2%±12.3%, P=.0130; at 60°: 90.5%±8.81%, P=.0079) and contact pressure (at 20°: 98.5%±5.71%, P=.0476; at 60°: 96.6%±1.13%, P=.0056) from the resected state. Contact pressure at 60° of flexion was significantly lower compared with the native labrum (P=.0420). For the Semi-T group, labral resection significantly decreased contact area (at 20°: 68.1%±12.57%, P=.0002; at 60°: 67.5%±6.70%, P=.0002) and increased contact pressure (at 20°: 105.3%±3.73%, P=.0304; at 60°: 106.8%±4.04%, P=.0231). Semi-T reconstruction improved contact area (at 20°: 87.9%±7.95%, P=.0087; at 60°: 92.9%±13

  3. Social Contacts and Mixing Patterns Relevant to the Spread of Infectious Diseases

    PubMed Central

    Mossong, Joël; Hens, Niel; Jit, Mark; Beutels, Philippe; Auranen, Kari; Mikolajczyk, Rafael; Massari, Marco; Salmaso, Stefania; Tomba, Gianpaolo Scalia; Wallinga, Jacco; Heijne, Janneke; Sadkowska-Todys, Malgorzata; Rosinska, Magdalena; Edmunds, W. John

    2008-01-01

    Background Mathematical modelling of infectious diseases transmitted by the respiratory or close-contact route (e.g., pandemic influenza) is increasingly being used to determine the impact of possible interventions. Although mixing patterns are known to be crucial determinants for model outcome, researchers often rely on a priori contact assumptions with little or no empirical basis. We conducted a population-based prospective survey of mixing patterns in eight European countries using a common paper-diary methodology. Methods and Findings 7,290 participants recorded characteristics of 97,904 contacts with different individuals during one day, including age, sex, location, duration, frequency, and occurrence of physical contact. We found that mixing patterns and contact characteristics were remarkably similar across different European countries. Contact patterns were highly assortative with age: schoolchildren and young adults in particular tended to mix with people of the same age. Contacts lasting at least one hour or occurring on a daily basis mostly involved physical contact, while short duration and infrequent contacts tended to be nonphysical. Contacts at home, school, or leisure were more likely to be physical than contacts at the workplace or while travelling. Preliminary modelling indicates that 5- to 19-year-olds are expected to suffer the highest incidence during the initial epidemic phase of an emerging infection transmitted through social contacts measured here when the population is completely susceptible. Conclusions To our knowledge, our study provides the first large-scale quantitative approach to contact patterns relevant for infections transmitted by the respiratory or close-contact route, and the results should lead to improved parameterisation of mathematical models used to design control strategies. PMID:18366252

  4. Patterns of cosmetic contact allergy.

    PubMed

    Castanedo-Tardan, Mari Paz; Zug, Kathryn A

    2009-07-01

    Certain patterns of dermatitis, such as those affecting the face, eyelids, lips, and neck, should raise the suspicion of a cosmetic-related contact allergy. Patch testing with a broad screening series, supplemented by a patient's own personal care products, should be considered when evaluating patients with suspected cosmetic dermatitis. Once the offending allergen is identified, an avoidance regimen should be established to avoid further exposure.

  5. Contact Us

    Science.gov Websites

    J8 | Force Structure, Resources & Assessment Contact Home : Contact Chairman's Social Media Chairman's Flicker Chairman's Blog SEAC's Social Media SEAC's Facebook SEAC's Flicker SEAC's Twitter Joint Staff's Social Media Joint Staff's Facebook Joint Staff's Flicker Joint Staff 's Twitter Social Media

  6. Does joint line elevation after revision knee arthroplasty affect tibio-femoral kinematics, contact pressure or collateral ligament lengths? An in vitro analysis

    PubMed Central

    Kowalczewski, Jacek B.; Chevalier, Yan; Okon, Tomasz; Innocenti, Bernardo; Bellemans, Johan

    2015-01-01

    Introduction Correct restoration of the joint line is generally considered as crucial when performing total knee arthroplasty (TKA). During revision knee arthroplasty however, elevation of the joint line occurs frequently. The general belief is that this negatively affects the clinical outcome, but the reasons are still not well understood. Material and methods In this cadaveric in vitro study the biomechanical consequences of joint line elevation were investigated using a previously validated cadaver model simulating active deep knee squats and passive flexion-extension cycles. Knee specimens were sequentially tested after total knee arthroplasty with joint line restoration and after 4 mm joint line elevation. Results The tibia rotated internally with increasing knee flexion during both passive and squatting motion (range: 17° and 7° respectively). Joint line elevation of 4 mm did not make a statistically significant difference. During passive motion, the tibia tended to become slightly more adducted with increasing knee flexion (range: 2°), while it went into slighlty less adduction during squatting (range: –2°). Neither of both trends was influenced by joint line elevation. Also anteroposterior translation of the femoral condyle centres was not affected by joint line elevation, although there was a tendency for a small posterior shift (of about 3 mm) during squatting after joint line elevation. In terms of kinetics, ligaments lengths and length changes, tibiofemoral contact pressures and quadriceps forces all showed the same patterns before and joint line elevation. No statistically significant changes could be detected. Conclusions Our study suggests that joint line elevation by 4 mm in revision total knee arthroplasty does not cause significant kinematic and kinetic differences during passive flexion/extension movement and squatting in the tibio-femoral joint, nor does it affect the elongation patterns of collateral ligaments. Therefore, clinical

  7. Relationship between knee joint contact forces and external knee joint moments in patients with medial knee osteoarthritis: effects of gait modifications.

    PubMed

    Richards, R E; Andersen, M S; Harlaar, J; van den Noort, J C

    2018-04-30

    To evaluate 1) the relationship between the knee contact force (KCF) and knee adduction and flexion moments (KAM and KFM) during normal gait in people with medial knee osteoarthritis (KOA), 2) the effects on the KCF of walking with a modified gait pattern and 3) the relationship between changes in the KCF and changes in the knee moments. We modeled the gait biomechanics of thirty-five patients with medial KOA using the AnyBody Modeling System during normal gait and two modified gait patterns. We calculated the internal KCF and evaluated the external joint moments (KAM and KFM) against it using linear regression analyses. First peak medial KCF was associated with first peak KAM (R 2  = 0.60) and with KAM and KFM (R 2  = 0.73). Walking with both modified gait patterns reduced KAM (P = 0.002) and the medial to total KCF ratio (P < 0.001) at the first peak. Changes in KAM during modified gait were moderately associated with changes in the medial KCF at the first peak (R 2  = 0.54 and 0.53). At the first peak, KAM is a reasonable substitute for the medial contact force, but not at the second peak. First peak KFM is also a significant contributor to the medial KCF. At the first peak, walking with a modified gait reduced the ratio of the medial to total KCF but not the medial KCF itself. To determine the effects of gait modifications on cartilage loading and disease progression, longitudinal studies and individualized modeling, accounting for motion control, would be required. Copyright © 2018 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. Social contact patterns can buffer costs of forgetting in the evolution of cooperation.

    PubMed

    Stevens, Jeffrey R; Woike, Jan K; Schooler, Lael J; Lindner, Stefan; Pachur, Thorsten

    2018-06-13

    Analyses of the evolution of cooperation often rely on two simplifying assumptions: (i) individuals interact equally frequently with all social network members and (ii) they accurately remember each partner's past cooperation or defection. Here, we examine how more realistic, skewed patterns of contact-in which individuals interact primarily with only a subset of their network's members-influence cooperation. In addition, we test whether skewed contact patterns can counteract the decrease in cooperation caused by memory errors (i.e. forgetting). Finally, we compare two types of memory error that vary in whether forgotten interactions are replaced with random actions or with actions from previous encounters. We use evolutionary simulations of repeated prisoner's dilemma games that vary agents' contact patterns, forgetting rates and types of memory error. We find that highly skewed contact patterns foster cooperation and also buffer the detrimental effects of forgetting. The type of memory error used also influences cooperation rates. Our findings reveal previously neglected but important roles of contact pattern, type of memory error and the interaction of contact pattern and memory on cooperation. Although cognitive limitations may constrain the evolution of cooperation, social contact patterns can counteract some of these constraints. © 2018 The Author(s).

  9. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    PubMed

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  10. Characterizing and Discovering Spatiotemporal Social Contact Patterns for Healthcare.

    PubMed

    Yang, Bo; Pei, Hongbin; Chen, Hechang; Liu, Jiming; Xia, Shang

    2017-08-01

    During an epidemic, the spatial, temporal and demographic patterns of disease transmission are determined by multiple factors. In addition to the physiological properties of the pathogens and hosts, the social contact of the host population, which characterizes the reciprocal exposures of individuals to infection according to their demographic structure and various social activities, are also pivotal to understanding and predicting the prevalence of infectious diseases. How social contact is measured will affect the extent to which we can forecast the dynamics of infections in the real world. Most current work focuses on modeling the spatial patterns of static social contact. In this work, we use a novel perspective to address the problem of how to characterize and measure dynamic social contact during an epidemic. We propose an epidemic-model-based tensor deconvolution framework in which the spatiotemporal patterns of social contact are represented by the factors of the tensors. These factors can be discovered using a tensor deconvolution procedure with the integration of epidemic models based on rich types of data, mainly heterogeneous outbreak surveillance data, socio-demographic census data and physiological data from medical reports. Using reproduction models that include SIR/SIS/SEIR/SEIS models as case studies, the efficacy and applications of the proposed framework are theoretically analyzed, empirically validated and demonstrated through a set of rigorous experiments using both synthetic and real-world data.

  11. Ankle Dorsiflexion Displacement During Landing is Associated With Initial Contact Kinematics but not Joint Displacement.

    PubMed

    Begalle, Rebecca L; Walsh, Meghan C; McGrath, Melanie L; Boling, Michelle C; Blackburn, J Troy; Padua, Darin A

    2015-08-01

    The ankle, knee, and hip joints work together in the sagittal plane to absorb landing forces. Reduced sagittal plane motion at the ankle may alter landing strategies at the knee and hip, potentially increasing injury risk; however, no studies have examined the kinematic relationships between the joints during jump landings. Healthy adults (N = 30; 15 male, 15 female) performed jump landings onto a force plate while three-dimensional kinematic data were collected. Joint displacement values were calculated during the loading phase as the difference between peak and initial contact angles. No relationship existed between ankle dorsiflexion displacement during landing and three-dimensional knee and hip displacements. However, less ankle dorsiflexion displacement was associated with landing at initial ground contact with larger hip flexion, hip internal rotation, knee flexion, knee varus, and smaller plantar flexion angles. Findings of the current study suggest that restrictions in ankle motion during landing may contribute to contacting the ground in a more flexed position but continuing through little additional motion to absorb the landing. Transverse plane hip and frontal plane knee positioning may also occur, which are known to increase the risk of lower extremity injury.

  12. Musculoskeletal multibody dynamics simulation of the contact mechanics and kinematics of a natural knee joint during a walking cycle.

    PubMed

    Hu, Jiayu; Chen, Zhenxian; Xin, Hua; Zhang, Qida; Jin, Zhongmin

    2018-05-01

    Detailed knowledge of the in vivo loading and kinematics in the knee joint is essential to understand its normal functions and the aetiology of osteoarthritis. Computer models provide a viable non-invasive solution for estimating joint loading and kinematics during different physiological activities. However, the joint loading and kinematics of the tibiofemoral and patellofemoral joints during a gait cycle were not typically investigated concurrently in previous computational simulations. In this study, a natural knee architecture was incorporated into a lower extremity musculoskeletal multibody dynamics model based on a force-dependent kinematics approach to investigate the contact mechanics and kinematics of a natural knee joint during a walking cycle. Specifically, the contact forces between the femoral/tibial articular cartilages and menisci and between the femoral and tibial/patellar articular cartilages were quantified. The contact forces and kinematics of the tibiofemoral and patellofemoral joints and the muscle activations and ligament forces were predicted simultaneously with a reasonable level of accuracy. The developed musculoskeletal multibody dynamics model with a natural knee architecture can serve as a potential platform for assisting clinical decision-making and postoperative rehabilitation planning.

  13. Contact stiffness of regularly patterned multi-asperity interfaces

    NASA Astrophysics Data System (ADS)

    Li, Shen; Yao, Quanzhou; Li, Qunyang; Feng, Xi-Qiao; Gao, Huajian

    2018-02-01

    Contact stiffness is a fundamental mechanical index of solid surfaces and relevant to a wide range of applications. Although the correlation between contact stiffness, contact size and load has long been explored for single-asperity contacts, our understanding of the contact stiffness of rough interfaces is less clear. In this work, the contact stiffness of hexagonally patterned multi-asperity interfaces is studied using a discrete asperity model. We confirm that the elastic interaction among asperities is critical in determining the mechanical behavior of rough contact interfaces. More importantly, in contrast to the common wisdom that the interplay of asperities is solely dictated by the inter-asperity spacing, we show that the number of asperities in contact (or equivalently, the apparent size of contact) also plays an indispensable role. Based on the theoretical analysis, we propose a new parameter for gauging the closeness of asperities. Our theoretical model is validated by a set of experiments. To facilitate the application of the discrete asperity model, we present a general equation for contact stiffness estimation of regularly rough interfaces, which is further proved to be applicable for interfaces with single-scale random roughness.

  14. Magnitude and Spatial Distribution of Impact Intensity Under the Foot Relates to Initial Foot Contact Pattern.

    PubMed

    Breine, Bastiaan; Malcolm, Philippe; Segers, Veerle; Gerlo, Joeri; Derie, Rud; Pataky, Todd; Frederick, Edward C; De Clercq, Dirk

    2017-12-01

    In running, foot contact patterns (rear-, mid-, or forefoot contact) influence impact intensity and initial ankle and foot kinematics. The aim of the study was to compare impact intensity and its spatial distribution under the foot between different foot contact patterns. Forty-nine subjects ran at 3.2 m·s -1 over a level runway while ground reaction forces (GRF) and shoe-surface pressures were recorded and foot contact pattern was determined. A 4-zone footmask (forefoot, midfoot, medial and lateral rearfoot) assessed the spatial distribution of the vertical GRF under the foot. We calculated peak vertical instantaneous loading rate of the GRF (VILR) per foot zone as the impact intensity measure. Midfoot contact patterns were shown to have the lowest, and atypical rearfoot contact patterns the highest impact intensities, respectively. The greatest local impact intensity was mainly situated under the rear- and midfoot for the typical rearfoot contact patterns, under the midfoot for the atypical rearfoot contact patterns, and under the mid- and forefoot for the midfoot contact patterns. These findings indicate that different foot contact patterns could benefit from cushioning in different shoe zones.

  15. Effects of Prosthetic Mismatch and Subscapularis Tear on Glenohumeral Contact Patterns in Total Shoulder Arthroplasty: A Numerical Musculoskeletal Analysis.

    PubMed

    Sins, Lauranne; Tétreault, Patrice; Nuño, Natalia; Hagemeister, Nicola

    2016-12-01

    Prosthetic components' mismatch and subscapularis (SC) tear are determining factors for glenoid failure complication in nonconforming total shoulder arthroplasty (NC-TSA). Risk factors are linked to glenoid prosthetic loading. However, the mechanisms underlying the clinical observations remain unclear. This study assessed the combined impact of mismatch and subscapularis tear on glenoid loading. It was assumed that adequate glenoid loading was associated with minimal, but non-null, humeral head translations and contact pressure, as well as with maximal glenoid contact area, and that the center of pressure (COP) on the glenoid would have a centered displacement pattern. A numerical model was used to achieve two objectives. The first was to verify whether an optimum mismatch existed, for which failure risk would be minimal. The second was to explore the effect of subscapularis tear on the position of applied forces on the glenoid. A shoulder AnyBody musculoskeletal model was adapted to the arthroplasty context by introducing humeral head translations and contact between implants. Ten simulations were computed to compare combinations of varying mismatches (1.4 mm, 3.4 mm, 6.4 mm, 8.6 mm, and 9 mm) with two shoulder conditions (intact-muscle or subscapularis tear). Humeral head translations, center-of-pressure, contact area, contact pressure, and glenohumeral joint contact forces were numerically estimated. Mismatches between 3.4 mm and 6.4 mm were associated with the most minimal humeral translations and contact pressure, as well as with maximal contact area. Center of pressure displacement pattern differed according to shoulder condition, with an outward anterior tendency in presence of tear.

  16. Thermal contact resistance measurement of conduction cooled binary current lead joint block in cryocooler based self field I-V characterization facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kundu, Ananya, E-mail: ananya@ipr.res.in; Das, Subrat Kumar; Agarwal, Anees Bano Pooja

    2016-05-23

    In the present study thermal resistance of conduction cooled current lead joint block employing two different interfacial material namely AlN sheet and Kapton Film have been studied in the temperature range 5K-35K. In each case, the performance of different interlayer materials e.g. Indium foil for moderately pressurized contacts (contact pressure <1 MPa), and Apiezon N Grease, GE varnish for low pressurized contact (contact pressure <1 MPa) is studied. The performances of AlN joint with Indium foil and with Apeizon N Grease are studied and it is observed that the contact resistance reduces more with indium foil as compared to greasedmore » contact. The contact resistance measurements of Kapton film with Apiezon N grease and with GE varnish were also carried out in the same temperature range. A comparative study of AlN joint with Indium foil and Kapton with GE varnish as filler material is carried out to demonstrate better candidate material among Kapton and AlN for a particular filler material in the same temperature range.« less

  17. Practical approach to subject-specific estimation of knee joint contact force

    PubMed Central

    Knarr, Brian A.; Higginson, Jill S.

    2015-01-01

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data, however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models’ predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. PMID:25952546

  18. Contact resistance improvement by the modulation of peripheral length to area ratio of graphene contact pattern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cho, Chunhum; Lee, Sangchul; Lee, Sang Kyung

    2015-05-25

    High contact resistance between graphene and metal is a major huddle for high performance electronic device applications of graphene. In this work, a method to improve the contact resistance of graphene is investigated by varying the ratio of peripheral length and area of graphene pattern under a metal contact. The contact resistance decreased to 0.8 kΩ·μm from 2.1 kΩ·μm as the peripheral length increased from 312 to 792 μm. This improvement is attributed to the low resistivity of edge-contacted graphene, which is 8.1 × 10{sup 5} times lower than that of top-contacted graphene.

  19. Influence of step length and landing pattern on patellofemoral joint kinetics during running.

    PubMed

    Willson, J D; Ratcliff, O M; Meardon, S A; Willy, R W

    2015-12-01

    Elevated patellofemoral joint kinetics during running may contribute to patellofemoral joint symptoms. The purpose of this study was to test for independent effects of foot strike pattern and step length on patellofemoral joint kinetics while running. Effects were tested relative to individual steps and also taking into account the number of steps required to run a kilometer with each step length. Patellofemoral joint reaction force and stress were estimated in 20 participants running at their preferred speed. Participants ran using a forefoot strike and rearfoot strike pattern during three different step length conditions: preferred step length, long (+10%) step length, and short (-10%) step length. Patellofemoral kinetics was estimated using a biomechanical model of the patellofemoral joint that accounted for cocontraction of the knee flexors and extensors. We observed independent effects of foot strike pattern and step length. Patellofemoral joint kinetics per step was 10-13% less during forefoot strike conditions and 15-20% less with a shortened step length. Patellofemoral joint kinetics per kilometer decreased 12-13% using a forefoot strike pattern and 9-12% with a shortened step length. To the extent that patellofemoral joint kinetics contribute to symptoms among runners, these running modifications may be advisable for runners with patellofemoral pain. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Soldier-relevant body borne loads increase knee joint contact force during a run-to-stop maneuver.

    PubMed

    Ramsay, John W; Hancock, Clifford L; O'Donovan, Meghan P; Brown, Tyler N

    2016-12-08

    The purpose of this study was to understand the effects of load carriage on human performance, specifically during a run-to-stop (RTS) task. Using OpenSim analysis tools, knee joint contact force, grounds reaction force, leg stiffness and lower extremity joint angles and moments were determined for nine male military personnel performing a RTS under three load configurations (light, ~6kg, medium, ~20kg, and heavy, ~40kg). Subject-based means for each biomechanical variable were submitted to repeated measures ANOVA to test the effects of load. During the RTS, body borne load significantly increased peak knee joint contact force by 1.2 BW (p<0.001) and peak vertical (p<0.001) and anterior-posterior (p=0.002) ground reaction forces by 0.6 BW and 0.3 BW, respectively. Body borne load also had a significant effect on hip (p=0.026) posture with the medium load and knee (p=0.046) posture with the heavy load. With the heavy load, participants exhibited a substantial, albeit non-significant increase in leg stiffness (p=0.073 and d=0.615). Increases in joint contact force exhibited during the RTS were primarily due to greater GRFs that impact the soldier with each incremental addition of body borne load. The stiff leg, extended knee and large braking force the soldiers exhibited with the heavy load suggests their injury risk may be greatest with that specific load configuration. Further work is needed to determine if the biomechanical profile exhibited with the heavy load configuration translates to unsafe shear forces at the knee joint and consequently, a higher likelihood of injury. Published by Elsevier Ltd.

  1. Tongue Palate Contact Patterns of Velar Stops in Normal Adult English Speakers

    ERIC Educational Resources Information Center

    Liker, Marko; Gibbon, Fiona E.

    2008-01-01

    This paper provides a more detailed description of normal tongue palate contact patterns for the occlusion phase of velar stops than currently exists. The study used electropalatography (EPG) to record seven normally speaking adults' contact patterns of voiceless velar stops in nine VkV contexts. A variety of EPG indices measured: per cent…

  2. Practical approach to subject-specific estimation of knee joint contact force.

    PubMed

    Knarr, Brian A; Higginson, Jill S

    2015-08-20

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data; however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models' predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Biomechanics of the natural, arthritic, and replaced human ankle joint

    PubMed Central

    2014-01-01

    The human ankle joint complex plays a fundamental role in gait and other activities of daily living. At the same time, it is a very complicated anatomical system but the large literature of experimental and modelling studies has not fully described the coupled joint motion, position and orientation of the joint axis of rotation, stress and strain in the ligaments and their role in guiding and stabilizing joint motion, conformity and congruence of the articular surfaces, patterns of contact at the articular surfaces, patterns of rolling and sliding at the joint surfaces, and muscle lever arm lengths. The present review article addresses these issues as described in the literature, reporting the most recent relevant findings. PMID:24499639

  4. Gunshot residue patterns on skin in angled contact and near contact gunshot wounds.

    PubMed

    Plattner, T; Kneubuehl, B; Thali, M; Zollinger, U

    2003-12-17

    The goal of this study was the reproduction of shape and pattern of gunshot residues in near contact and contact gunshot wounds by a series of experimental gunshots on a skin and soft tissue model. The aim was to investigate the shape and direction of soot deposits with regard to the muzzle according to different muzzle-target angles, firing distances, type of ammunition and weapon and barrel length. Based on a review of the literature and on the results of the experiments the authors could make the following statements of gunshot residues in angled contact and close contact gunshot: (1) gunshot residues on the target surface can be differentiated in a "inner" and "outer powder soot zone"; (2) the outer powder soot zone is much less visible than the inner powder soot zone and may lack on human skin; (3) with increasing muzzle target distance both inner and outer powder soot halo increase in size and decrease in density; (4) in angled shots the inner powder soot halo shows an eccentric, elliptic shape which points towards the muzzle, regardless of ammunition, calibre and barrel length; (5) the outer powder soot points away from the muzzle in angled contact and close contact shots.

  5. Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.

    PubMed

    Pawaskar, Sainath Shrikant; Ingham, Eileen; Fisher, John; Jin, Zhongmin

    2011-01-01

    The articular cartilage covering the ends of the bones of diarthrodial synovial joints is thought to have evolved so that the loads are transferred under different and complex conditions, with a very high degree of efficiency and without compromising the structural integrity of the tissue for the life of an individual. These loading conditions stem from different activities such as walking, and standing. The integrity of cartilage may however become compromised due to congenital disease, arthritis or trauma. Hemiarthroplasty is a potentially conservative treatment when only the femoral cartilage is affected as in case of femoral neck fractures. In hemiarthroplasty, a metallic femoral prosthesis is used to articulate against the natural acetabular cartilage. It has also been hypothesized that biphasic lubrication is the predominant mechanism protecting the cartilage through a very high fluid load support which lowers friction. This may be altered due to hemiarthroplasty and have a direct effect on the frictional shear stresses and potentially cartilage degradation and wear. This study modelled nine activities of daily living and investigated the contact mechanics of a hip joint with a hemiarthroplasty, focussing particularly on the role of the fluid phase. It was shown that in most of the activities studied the peak contact stresses and peak fluid pressures were in the superior dome or lateral roof of the acetabulum. Total fluid load support was very high (~90%) in most of the activities which would shield the solid phase from being subjected to very high contact stresses. This was dependent not only on the load magnitude but also the direction and hence on the location of the contact area with respect to the cartilage coverage. Lower fluid load support was found when the contact area was nearer the edges where the fluid drained easily. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Improving contact layer patterning using SEM contour based etch model

    NASA Astrophysics Data System (ADS)

    Weisbuch, François; Lutich, Andrey; Schatz, Jirka; Hertzsch, Tino; Moll, Hans-Peter

    2016-10-01

    The patterning of the contact layer is modulated by strong etch effects that are highly dependent on the geometry of the contacts. Such litho-etch biases need to be corrected to ensure a good pattern fidelity. But aggressive designs contain complex shapes that can hardly be compensated with etch bias table and are difficult to characterize with standard CD metrology. In this work we propose to implement a model based etch compensation method able to deal with any contact configuration. With the help of SEM contours, it was possible to get reliable 2D measurements particularly helpful to calibrate the etch model. The selections of calibration structures was optimized in combination with model form to achieve an overall errRMS of 3nm allowing the implementation of the model in production.

  7. Reduced step length reduces knee joint contact forces during running following anterior cruciate ligament reconstruction but does not alter inter-limb asymmetry.

    PubMed

    Bowersock, Collin D; Willy, Richard W; DeVita, Paul; Willson, John D

    2017-03-01

    Anterior cruciate ligament reconstruction is associated with early onset knee osteoarthritis. Running is a typical activity following this surgery, but elevated knee joint contact forces are thought to contribute to osteoarthritis degenerative processes. It is therefore clinically relevant to identify interventions to reduce contact forces during running among individuals after anterior cruciate ligament reconstruction. The primary purpose of this study was to evaluate the effect of reducing step length during running on patellofemoral and tibiofemoral joint contact forces among people with a history of anterior cruciate ligament reconstruction. Inter limb knee joint contact force differences during running were also examined. 18 individuals at an average of 54.8months after unilateral anterior cruciate ligament reconstruction ran in 3 step length conditions (preferred, -5%, -10%). Bilateral patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, loading rate, impulse, and impulse per kilometer were evaluated between step length conditions and limbs using separate 2 factor analyses of variance. Reducing step length 5% decreased patellofemoral, tibiofemoral, and medial tibiofemoral compartment peak force, impulse, and impulse per kilometer bilaterally. A 10% step length reduction further decreased peak forces and force impulses, but did not further reduce force impulses per kilometer. Tibiofemoral joint impulse, impulse per kilometer, and patellofemoral joint loading rate were lower in the previously injured limb compared to the contralateral limb. Running with a shorter step length is a feasible clinical intervention to reduce knee joint contact forces during running among people with a history of anterior cruciate ligament reconstruction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Comparison of MRI-based estimates of articular cartilage contact area in the tibiofemoral joint.

    PubMed

    Henderson, Christopher E; Higginson, Jill S; Barrance, Peter J

    2011-01-01

    Knee osteoarthritis (OA) detrimentally impacts the lives of millions of older Americans through pain and decreased functional ability. Unfortunately, the pathomechanics and associated deviations from joint homeostasis that OA patients experience are not well understood. Alterations in mechanical stress in the knee joint may play an essential role in OA; however, existing literature in this area is limited. The purpose of this study was to evaluate the ability of an existing magnetic resonance imaging (MRI)-based modeling method to estimate articular cartilage contact area in vivo. Imaging data of both knees were collected on a single subject with no history of knee pathology at three knee flexion angles. Intra-observer reliability and sensitivity studies were also performed to determine the role of operator-influenced elements of the data processing on the results. The method's articular cartilage contact area estimates were compared with existing contact area estimates in the literature. The method demonstrated an intra-observer reliability of 0.95 when assessed using Pearson's correlation coefficient and was found to be most sensitive to changes in the cartilage tracings on the peripheries of the compartment. The articular cartilage contact area estimates at full extension were similar to those reported in the literature. The relationships between tibiofemoral articular cartilage contact area and knee flexion were also qualitatively and quantitatively similar to those previously reported. The MRI-based knee modeling method was found to have high intra-observer reliability, sensitivity to peripheral articular cartilage tracings, and agreeability with previous investigations when using data from a single healthy adult. Future studies will implement this modeling method to investigate the role that mechanical stress may play in progression of knee OA through estimation of articular cartilage contact area.

  9. Experimental methodology of contact edge roughness on sub-100-nm pattern

    NASA Astrophysics Data System (ADS)

    Lee, Tae Yong; Ihm, Dongchul; Kang, Hyo Chun; Lee, Jun Bum; Lee, Byoung-Ho; Chin, Soo-Bok; Cho, Do-Hyun; Kim, Yang Hyong; Yang, Ho Dong; Yang, Kyoung Mo

    2004-05-01

    The measurement of edge roughness has become a hot issue in the semiconductor industry. Major vendors offer a variety of features to measure the edge roughness in their CD-SEMs. However, most of the features are limited by the applicable pattern types. For the line and space patterns, features such as Line Edge Roughness (LER) and Line Width Roughness (LWR) are available in current CD-SEMs. The edge roughness is more critical in contact process. However the measurement of contact edge roughness (CER) or contact space roughness (CSR) is more complicated than that of LER or LWR. So far, no formal standard measurement algorithm or definition of contact roughness measurement exists. In this article, currently available features are investigated to assess their representability for CER or CSR. Some new ideas to quantify CER and CSR were also suggested with preliminary experimental results.

  10. Social contact patterns relevant to the spread of respiratory infectious diseases in Hong Kong.

    PubMed

    Leung, Kathy; Jit, Mark; Lau, Eric H Y; Wu, Joseph T

    2017-08-11

    The spread of many respiratory infections is determined by contact patterns between infectious and susceptible individuals in the population. There are no published data for quantifying social contact patterns relevant to the spread of respiratory infectious diseases in Hong Kong which is a hotspot for emerging infectious diseases due to its high population density and connectivity in the air transportation network. We adopted a commonly used diary-based design to conduct a social contact survey in Hong Kong in 2015/16 using both paper and online questionnaires. Participants using paper questionnaires reported more contacts and longer contact duration than those using online questionnaires. Participants reported 13 person-hours of contact and 8 contacts per day on average, which decreased over age but increased with household size, years of education and income level. Prolonged and frequent contacts, and contacts at home, school and work were more likely to involve physical contacts. Strong age-assortativity was observed in all age groups. We evaluated the characteristics of social contact patterns relevant to the spread of respiratory infectious diseases in Hong Kong. Our findings could help to improve the design of future social contact surveys, parameterize transmission models of respiratory infectious diseases, and inform intervention strategies based on model outputs.

  11. New approach for pattern collapse problem by increasing contact area at sub-100nm patterning

    NASA Astrophysics Data System (ADS)

    Lee, Sung-Koo; Jung, Jae Chang; Lee, Min Suk; Lee, Sung K.; Kim, Sam Young; Hwang, Young-Sun; Bok, Cheol K.; Moon, Seung-Chan; Shin, Ki S.; Kim, Sang-Jung

    2003-06-01

    To accomplish minimizing feature size to sub 100nm, new light sources for photolithography are emerging, such as ArF(193nm), F2(157nm), and EUV(13nm). However as the pattern size decreases to sub 100nm, a new obstacle, that is pattern collapse problem, becomes most serious bottleneck to the road for the sub 100 nm lithography. The main reason for this pattern collapse problem is capillary force that is increased as the pattern size decreases. As a result there were some trials to decrease this capillary force by changing developer or rinse materials that had low surface tension. On the other hands, there were other efforts to increase adhesion between resists and sub materials (organic BARC). In this study, we will propose a novel approach to solve pattern collapse problems by increasing contact area between sub material (organic BARC) and resist pattern. The basic concept of this approach is that if nano-scale topology is made at the sub material, the contact area between sub materials and resist will be increased. The process scheme was like this. First after coating and baking of organic BARC material, the nano-scale topology (3~10nm) was made by etching at this organic BARC material. On this nano-scale topology, resist was coated and exposed. Finally after develop, the contact area between organic BARC and resist could be increased. Though nano-scale topology was made by etching technology, this 20nm topology variation induced large substrate reflectivity of 4.2% and as a result the pattern fidelity was not so good at 100nm 1:1 island pattern. So we needed a new method to improve pattern fidelity problem. This pattern fidelity problem could be solved by introducing a sacrificial BARC layer. The process scheme was like this. First organic BARC was coated of which k value was about 0.64 and then sacrificial BARC layers was coated of which k value was about 0.18 on the organic BARC. The nano-scale topology (1~4nm) was made by etching of this sacrificial BARC layer

  12. Calculation of muscle loading and joint contact forces during the rock step in Irish dance.

    PubMed

    Shippen, James M; May, Barbara

    2010-01-01

    A biomechanical model for the analysis of dancers and their movements is described. The model consisted of 31 segments, 35 joints, and 539 muscles, and was animated using movement data obtained from a three-dimensional optical tracking system that recorded the motion of dancers. The model was used to calculate forces within the muscles and contact forces at the joints of the dancers in this study. Ground reaction forces were measured using force plates mounted in a sprung floor. The analysis procedure is generic and can be applied to any dance form. As an exemplar of the application process an Irish dance step, the rock, was analyzed. The maximum ground reaction force found was 4.5 times the dancer's body weight. The muscles connected to the Achilles tendon experienced a maximum force comparable to their maximal isometric strength. The contact force at the ankle joint was 14 times body weight, of which the majority of the force was due to muscle contraction. It is suggested that as the rock step produces high forces, and therefore the potential to cause injury, its use should be carefully monitored.

  13. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    PubMed

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  14. Validation of radiocarpal joint contact models based on images from a clinical MRI scanner.

    PubMed

    Johnson, Joshua E; McIff, Terence E; Lee, Phil; Toby, E Bruce; Fischer, Kenneth J

    2014-01-01

    This study was undertaken to assess magnetic resonance imaging (MRI)-based radiocarpal surface contact models of functional loading in a clinical MRI scanner for future in vivo studies, by comparison with experimental measures from three cadaver forearm specimens. Experimental data were acquired using a Tekscan sensor during simulated light grasp. Magnetic resonance (MR) images were used to obtain model geometry and kinematics (image registration). Peak contact pressures (PPs) and average contact pressures (APs), contact forces and contact areas were determined in the radiolunate and radioscaphoid joints. Contact area was also measured directly from MR images acquired with load and compared with model data. Based on the validation criteria (within 25% of experimental data), out of the six articulations (three specimens with two articulations each), two met the criterion for AP (0%, 14%); one for peak pressure (20%); one for contact force (5%); four for contact area with respect to experiment (8%, 13%, 19% and 23%), and three contact areas met the criterion with respect to direct measurements (14%, 21% and 21%). Absolute differences between model and experimental PPs were reasonably low (within 2.5 MPa). Overall, the results indicate that MRI-based models generated from 3T clinical MR scanner appear sufficient to obtain clinically relevant data.

  15. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy.

    PubMed

    Nieuwenhuys, Angela; Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with 'no or minor gait deviations' (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with 'no or minor gait deviations' differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus study

  16. A neural network approach for determining gait modifications to reduce the contact force in knee joint implant.

    PubMed

    Ardestani, Marzieh Mostafavizadeh; Chen, Zhenxian; Wang, Ling; Lian, Qin; Liu, Yaxiong; He, Jiankang; Li, Dichen; Jin, Zhongmin

    2014-10-01

    There is a growing interest in non-surgical gait rehabilitation treatments to reduce the loading in the knee joint. In particular, synergetic kinematic changes required for joint offloading should be determined individually for each subject. Previous studies for gait rehabilitation designs are typically relied on a "trial-and-error" approach, using multi-body dynamic (MBD) analysis. However MBD is fairly time demanding which prevents it to be used iteratively for each subject. This study employed an artificial neural network to develop a cost-effective computational framework for designing gait rehabilitation patterns. A feed forward artificial neural network (FFANN) was trained based on a number of experimental gait trials obtained from literature. The trained network was then hired to calculate the appropriate kinematic waveforms (output) needed to achieve desired knee joint loading patterns (input). An auxiliary neural network was also developed to update the ground reaction force and moment profiles with respect to the predicted kinematic waveforms. The feasibility and efficiency of the predicted kinematic patterns were then evaluated through MBD analysis. Results showed that FFANN-based predicted kinematics could effectively decrease the total knee joint reaction forces. Peak values of the resultant knee joint forces, with respect to the bodyweight (BW), were reduced by 20% BW and 25% BW in the midstance and the terminal stance phases. Impulse values of the knee joint loading patterns were also decreased by 17% BW*s and 24%BW*s in the corresponding phases. The FFANN-based framework suggested a cost-effective forward solution which directly calculated the kinematic variations needed to implement a given desired knee joint loading pattern. It is therefore expected that this approach provides potential advantages and further insights into knee rehabilitation designs. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Gait alterations to effectively reduce hip contact forces.

    PubMed

    Wesseling, Mariska; de Groote, Friedl; Meyer, Christophe; Corten, Kristoff; Simon, Jean-Pierre; Desloovere, Kaat; Jonkers, Ilse

    2015-07-01

    Patients with hip pathology present alterations in gait which have an effect on joint moments and loading. In knee osteoarthritic patients, the relation between medial knee contact forces and the knee adduction moment are currently being exploited to define gait retraining strategies to effectively reduce pain and disease progression. However, the relation between hip contact forces and joint moments has not been clearly established. Therefore, this study aims to investigate the effect of changes in hip and pelvis kinematics during gait on internal hip moments and contact forces which is calculated using muscle driven simulations. The results showed that frontal plane kinetics have the largest effect on hip contact forces. Given the high correlation between the change in hip adduction moment and contact force at initial stance (R(2)  = 0.87), this parameter can be used to alter kinematics and predict changes in contact force. At terminal stance the hip adduction and flexion moment can be used to predict changes in contact force (R(2)  = 0.76). Therefore, gait training that focuses on decreasing hip adduction moments, a wide base gait pattern, has the largest potential to reduce hip contact forces. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Different knee joint loading patterns in ACL deficient copers and non-copers during walking.

    PubMed

    Alkjær, Tine; Henriksen, Marius; Simonsen, Erik B

    2011-04-01

    Rupture of the anterior cruciate ligament (ACL) causes changes in the walking pattern. ACL deficient subjects classified as copers and non-copers have been observed to adopt different post-injury walking patterns. How these different patterns affect the knee compression and shear forces is unresolved. Thus, the aim of the present study was to investigate how different walking patterns observed between copers, non-copers, and controls affect the knee compression and shear forces during walking. Three-dimensional gait analyses were performed in copers (n = 9), non-copers (n = 10), and control subjects (n =19). The net knee joint moment, knee joint reaction forces, and the sagittal knee joint angle were input parameters to a biomechanical model that assessed the knee compression and shear forces. The results showed that the non-copers walked with significantly reduced knee compression and shear forces than the controls. The overall knee compression force pattern was similar between the copers and controls, although this variable was significantly increased at heel strike in the copers compared to both non-copers and controls. The peak shear force was significantly dependent on the peak knee extensor moment. This covariance was significantly different between groups meaning that at a given knee extensor moment the shear force was significantly reduced in the copers compared to controls. The different knee joint loading patterns observed between non-copers and copers reflected the different walking strategies adopted by these groups, which may have implications for the knee joint stability. The strategy adopted by the copers may resemble an effective way to stabilize the knee joint during walking after an ACL rupture and that the knee kinematics may play a key role for this strategy. It is clinically relevant to investigate if gait retraining would enable non-copers to walk as copers and thereby improve their knee joint stability.

  19. Compressive and shear hip joint contact forces are affected by pediatric obesity during walking

    PubMed Central

    Lerner, Zachary F.; Browning, Raymond C.

    2016-01-01

    Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected during treadmill walking at 1 m•s−1 in 10 obese and 10 healthy-weight 8–12 year-olds. We estimated body composition, segment masses, lower-extremity alignment, and femoral neck angle via radiographic images, created personalized musculoskeletal models in OpenSim, and computed muscle forces and hip joint contact forces. Hip extension at mid-stance was 9° less, on average, in the obese children (p<0.001). Hip abduction, knee flexion, and body-weight normalized peak hip moments were similar between groups. Normalized to body-weight, peak contact forces were similar at the first peak and slightly lower at the second peak between the obese and healthy-weight participants. Total body mass explained a greater proportion of contact force variance compared to lean body mass in the compressive (r2=0.89) and vertical shear (perpendicular to the physis acting superior-to-inferior) (r2=0.84) directions; lean body mass explained a greater proportion in the posterior shear direction (r2=0.54). Stance-average contact forces in the compressive and vertical shear directions increased by 41 N and 48 N, respectively, for every kilogram of body mass. Age explained less than 27% of the hip loading variance. No effect of sex was found. The proportionality between hip loads and body-weight may be implicated in an obese child’s increased risk of hip pain and pathology. PMID:27040390

  20. Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

    PubMed

    Lerner, Zachary F; Browning, Raymond C

    2016-06-14

    Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected during treadmill walking at 1ms(-1) in 10 obese and 10 healthy-weight 8-12 year-olds. We estimated body composition, segment masses, lower-extremity alignment, and femoral neck angle via radiographic images, created personalized musculoskeletal models in OpenSim, and computed muscle forces and hip joint contact forces. Hip extension at mid-stance was 9° less, on average, in the obese children (p<0.001). Hip abduction, knee flexion, and body-weight normalized peak hip moments were similar between groups. Normalized to body-weight, peak contact forces were similar at the first peak and slightly lower at the second peak between the obese and healthy-weight participants. Total body mass explained a greater proportion of contact force variance compared to lean body mass in the compressive (r(2)=0.89) and vertical shear (perpendicular to the physis acting superior-to-inferior) (r(2)=0.84) directions; lean body mass explained a greater proportion in the posterior shear direction (r(2)=0.54). Stance-average contact forces in the compressive and vertical shear directions increased by 41N and 48N, respectively, for every kilogram of body mass. Age explained less than 27% of the hip loading variance. No effect of sex was found. The proportionality between hip loads and body-weight may be implicated in an obese child׳s increased risk of hip pain and pathology. Published by Elsevier Ltd.

  1. In Vivo Patellar Tracking and Patellofemoral Cartilage Contacts during Dynamic Stair Ascending

    PubMed Central

    Suzuki, Takashi; Hosseini, Ali; Li, Jing-Sheng; Gill, Thomas J; Li, Guoan

    2012-01-01

    The knowledge of normal patellar tracking is essential for understanding of the knee joint function and for diagnosis of patellar instabilities. This paper investigated the patellar tracking and patellofemoral joint contact locations during a stair ascending activity using a validated dual-fluoroscopic imaging system. The results showed that the patellar flexion angle decreased from 41.9° to 7.5° with the knee extension during stair ascending. During first 80% of the activity, the patella shifted medially about 3.9 mm and then slightly shifted laterally during the last 20% of the ascending activity. Anterior translation of 13 mm of the patella was measured at the early 80% of the activity and then slightly moved posteriorly by about 2 mm at the last 20% of the activity. The path of the cartilage contact points was slightly lateral on the cartilage surfaces of patella and femur. On the patellar cartilage surface, the cartilage contact locations were about 2 mm laterally from heel strike to 60% of the stair ascending activity and moved laterally and reached 5.3 mm at full extension. However, the cartilage contact locations were relatively constant on the femoral cartilage surface (~5 mm lateral). The patellar tracking pattern was consistent with the patellofemoral cartilage contact location pattern. These data could provide baseline knowledge for understanding of normal physiology of the patellofemoral joint and can be used as a reference for clinical evaluation of patellofemoral disorder symptoms. PMID:22840488

  2. Statistical Parametric Mapping to Identify Differences between Consensus-Based Joint Patterns during Gait in Children with Cerebral Palsy

    PubMed Central

    Papageorgiou, Eirini; Desloovere, Kaat; Molenaers, Guy; De Laet, Tinne

    2017-01-01

    Experts recently identified 49 joint motion patterns in children with cerebral palsy during a Delphi consensus study. Pattern definitions were therefore the result of subjective expert opinion. The present study aims to provide objective, quantitative data supporting the identification of these consensus-based patterns. To do so, statistical parametric mapping was used to compare the mean kinematic waveforms of 154 trials of typically developing children (n = 56) to the mean kinematic waveforms of 1719 trials of children with cerebral palsy (n = 356), which were classified following the classification rules of the Delphi study. Three hypotheses stated that: (a) joint motion patterns with ‘no or minor gait deviations’ (n = 11 patterns) do not differ significantly from the gait pattern of typically developing children; (b) all other pathological joint motion patterns (n = 38 patterns) differ from typically developing gait and the locations of difference within the gait cycle, highlighted by statistical parametric mapping, concur with the consensus-based classification rules. (c) all joint motion patterns at the level of each joint (n = 49 patterns) differ from each other during at least one phase of the gait cycle. Results showed that: (a) ten patterns with ‘no or minor gait deviations’ differed somewhat unexpectedly from typically developing gait, but these differences were generally small (≤3°); (b) all other joint motion patterns (n = 38) differed from typically developing gait and the significant locations within the gait cycle that were indicated by the statistical analyses, coincided well with the classification rules; (c) joint motion patterns at the level of each joint significantly differed from each other, apart from two sagittal plane pelvic patterns. In addition to these results, for several joints, statistical analyses indicated other significant areas during the gait cycle that were not included in the pattern definitions of the consensus

  3. Contact formation and patterning approaches for group-III nitride light emitters

    NASA Astrophysics Data System (ADS)

    Hou, Wenting

    Solid state lighting via light emitting diodes (LEDs) and laser diodes (LDs) is a rapidly progressing technology with the potential to greatly exceed the efficiency of traditional lighting systems. This dissertation focuses on the development of electrical contacts and patterning schemes for highly efficient green LEDs and LD structures. Efficiency of LEDs can be greatly improved by means of nano-patterning processes. LEDs grown on nano-imprint patterned sapphire substrates showed promising performance, with improvement in both internal quantum efficiency and light extraction efficiency. As an alternative to nano-imprint lithography, this study utilized a simple method to generate irregular nano-patterns by a Ni self-assembly process and applied the process to both sapphire substrate and n-GaN template. In both approaches, the nano-patterned LEDs showed an improvement in light output power. For the device fabrication of LEDs and LDs, low-resistance ohmic contacts are essential for high efficiency. In search of a highly transparent ohmic contact to p-type GaN, I analyzed various metal/indium-tin-oxide (ITO) (Ag/ITO, AgCu/ITO, Ni/ITO, and NiZn/ITO) contact schemes and compared them with Ni/Au, NiZn/Ag, and ITO contacts. For ITO-based contacts, the inserted metal layer can boost conductivity while the ITO thickness can be optimized for constructive transmission interference on GaN exceeding the extraction from bare GaN. The best compromise was obtained for an Ag/ITO (3 nm /67 nm) ohmic contact, with a relative transmittance of 97% of the bare GaN near 530 nm, and a specific contact resistance of 3x10-2 O·cm 2. The contact proved particularly suitable for green light emitting diodes in epi-up geometry. Graphene as another alternative transparent p-contact was also evaluated. Furthermore, this dissertation offered a pre-deposition treatment to contact schemes on undoped and n-doped GaN, rendering a standard post-deposition annealing step unnecessary. As-deposited Ti

  4. Skeletal pattern in subjects with temporomandibular joint disorders

    PubMed Central

    Almăşan, Oana Cristina; Almăşan, Horea Artimoniu; Bran, Simion; Lascu, Liana; Iancu, Mihaela; Băciuţ, Grigore

    2013-01-01

    Introduction To establish the skeletal pattern in subjects with malocclusions and temporomandibular disorders (TMD); to assess the relationship between craniofacial skeletal structures and TMD in subjects with malocclusions. Material and methods Sixty-four subjects with malocclusions, over 18 years of age, were included in the study. Temporomandibular disorders were clinically assessed according to the Helkimo Anamnestic Index. Subjects underwent a lateral cephalogram. Subjects were grouped according to the sagittal skeletal pattern (ANB angle) into class I, II and III. Parametric Student tests with equal or unequal variations were used (variations were previously tested with Levene test). Results Twenty-four patients with TMD (experimental sample); 40 patients without TMD (control group); interincisal angle was higher in class I and II (p < 0.05) experimental subjects; overjet was larger in experimental subjects; midline shift and Wits appraisal were broader in the experimental group in all three classes. In class III subjects, the SNB angle was higher in the experimental group (p = 0.01). Joint noises followed by reduced mandible mobility, muscular pain and temporomandibular joint (TMJ) pain were the most frequent symptoms in subjects with TMD and malocclusions. Conclusions Temporomandibular joint status is an important factor to consider when planning orthodontic treatment in patients with severe malocclusions; midline shift, large overjet and deep overbite have been associated with signs and symptoms of TMD. PMID:23515361

  5. Associating sex-biased and seasonal behaviour with contact patterns and transmission risk in Gopherus agassizii

    USGS Publications Warehouse

    Aiello, Christina M.; Esque, Todd; Nussear, K. E.; Emblidge, P. G.; Hudson, P. J.

    2018-01-01

    Interactions between wildlife hosts act as transmission routes for directly transmitted pathogens and vary in ways that affect transmission efficiency. Identifying drivers of contact variation can allow both contact inference and estimation of transmission dynamics despite limited data. In desert tortoises, mating strategy, burrow use and seasonal change influence numerous behaviours and likely shape contact patterns. In this study, we ask to what extent tortoise contact behaviour varies between sexes and seasons, and whether space or burrow-use data can be used to infer contact characteristics consistent with those recorded by proximity loggers. We identified sex and season-biased contact behaviour in both wild and captive populations indicative of female-female avoidance and seasonal male mate-seeking behaviour. Space and burrow-use patterns were informative, but did not always predict the extent of sex or seasonal biases on contact. We discuss the implications these findings have for transmission patterns and disease mitigation in tortoise populations.

  6. Contact characteristics of the subtalar joint after a simulated calcaneus fracture.

    PubMed

    Sangeorzan, B J; Ananthakrishnan, D; Tencer, A F

    1995-06-01

    A simple calcaneus fracture consisting of two parts was modeled in nine fresh cadaver hindfoot specimens to assess changes in subtalar joint contact characteristics with increasing plantar depression of the posterolateral fracture component. To perform the experiment, rods were placed in the tibial and fibular shafts of each specimen, which was mounted in a frame in neutral stance. A pneumatic cylinder was used to deliver a vertical compressive load through the rods into the foot while permitting free motion of the foot in the horizontal plane. Sealed packets of pressure-sensitive film were inserted into the anterior-middle and posterior facets of the talocalcaneal articulation, and a 700-N load was applied. After testing of the intact foot, a primary fracture line was created using a microoscillating saw. The osteotomized posterolateral component was anatomically reduced and fixed, the film inserted, and the load reapplied. The test was repeated after the posterolateral fragment was displaced 2, 5, and 10 mm in a plantar direction. The resulting pressure prints were scanned along with pressure/color density calibration strips using a flat-bed scanner, and an image analysis system was used to determine contact areas within specified pressure intervals. The contact area (> 0.5 MPa) of the posterior facet was significantly decreased with 2, 5, and 10 mm displacements of the posterolateral calcaneus fracture component. The ratio of high-pressure area (< 5.0 MPa) to contact area in the posterior facet was significantly increased only with displacements of 5 and 10 mm. There were no significant changes in any contact parameters in the anterior-middle facet.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys.

    PubMed

    Mastrandrea, Rossana; Fournet, Julie; Barrat, Alain

    2015-01-01

    Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i) face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii) self-reported friendship surveys, and (iii) online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self-reported contacts and

  8. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys

    PubMed Central

    Mastrandrea, Rossana; Fournet, Julie; Barrat, Alain

    2015-01-01

    Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i) face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii) self-reported friendship surveys, and (iii) online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self-reported contacts and

  9. The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers.

    PubMed

    Li, Junyan; Stewart, Todd D; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John

    2013-06-21

    Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers☆

    PubMed Central

    Li, Junyan; Stewart, Todd D.; Jin, Zhongmin; Wilcox, Ruth K.; Fisher, John

    2013-01-01

    Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000 s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. PMID:23664238

  11. Geared Electromechanical Rotary Joint

    NASA Technical Reports Server (NTRS)

    Vranish, John M.

    1994-01-01

    Geared rotary joint provides low-noise ac or dc electrical contact between electrical subsystems rotating relative to each other. Designed to overcome some disadvantages of older electromechanical interfaces, especially intermittency of sliding-contact and rolling-contact electromechanical joints. Hollow, springy planetary gears provide continuous, redundant, low-noise electrical contact between inner and outer gears.

  12. Who's holding the baby? A prospective diary study of the contact patterns of mothers with an infant.

    PubMed

    Campbell, Patricia Therese; McVernon, Jodie; Shrestha, Niraj; Nathan, Paula M; Geard, Nicholas

    2017-09-20

    Models of infectious disease are increasingly utilising empirical contact data to quantify the number of potentially infectious contacts between age groups. While a growing body of data is being collected on contact patterns across many populations, less attention has been paid to the social contacts of young infants. We collected information on the social contacts of primary carers of young infants and investigated their potential for use as a proxy for contacts made by their infant. We recruited primary carers of infants under one year of age residing in two geographically, demographically and socioeconomically distinct local government areas of Melbourne, Australia - Boroondara and Hume - including a sub-group of Turkish-speaking participants. Participants recorded their own contacts in a paper diary and noted whether their infant was present or absent. Information collected included times at an address; description of location; and details on people contacted at the location. Descriptive summary measures and distributions of contacts by location type, intensity, day of contact and by age are reported. Of the 226 participants recruited, 220 completed diaries were returned. Participant contact patterns were similar across all groups, with respect to the types of locations, intensity and day of contact, with some variation in the number of unique daily contacts. The infant was present at around 85% of locations at which the primary carer contacted other individuals. The majority of contacts occurring when the infant was present were in Own Home (32%), Retail and Hospitality (18%) and Transport (18%) settings. The mean daily number of unique contacts by infants was estimated as 9.1, 8.7 and 6.5 in Boroondara, Hume (English) and Hume (Turkish), respectively, with a similar age distribution across each of our surveyed groups. Our demonstration that contact patterns of mothers with infants are reasonably robust to socioeconomic and cultural differences is a step

  13. We'll Meet Again: Revealing Distributional and Temporal Patterns of Social Contact

    PubMed Central

    Pachur, Thorsten; Schooler, Lael J.; Stevens, Jeffrey R.

    2014-01-01

    What are the dynamics and regularities underlying social contact, and how can contact with the people in one's social network be predicted? In order to characterize distributional and temporal patterns underlying contact probability, we asked 40 participants to keep a diary of their social contacts for 100 consecutive days. Using a memory framework previously used to study environmental regularities, we predicted that the probability of future contact would follow in systematic ways from the frequency, recency, and spacing of previous contact. The distribution of contact probability across the members of a person's social network was highly skewed, following an exponential function. As predicted, it emerged that future contact scaled linearly with frequency of past contact, proportionally to a power function with recency of past contact, and differentially according to the spacing of past contact. These relations emerged across different contact media and irrespective of whether the participant initiated or received contact. We discuss how the identification of these regularities might inspire more realistic analyses of behavior in social networks (e.g., attitude formation, cooperation). PMID:24475073

  14. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings

    PubMed Central

    Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A.; Vanrenterghem, Jos; Verschueren, Sabine

    2016-01-01

    Purpose The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Methods Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. Results The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). Conclusion This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an

  15. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings.

    PubMed

    Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine

    2016-01-01

    The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05). Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001). The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05). Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001). Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001). This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior

  16. Morphogen-based simulation model of ray growth and joint patterning during fin development and regeneration.

    PubMed

    Rolland-Lagan, Anne-Gaëlle; Paquette, Mathieu; Tweedle, Valerie; Akimenko, Marie-Andrée

    2012-03-01

    The fact that some organisms are able to regenerate organs of the correct shape and size following amputation is particularly fascinating, but the mechanism by which this occurs remains poorly understood. The zebrafish (Danio rerio) caudal fin has emerged as a model system for the study of bone development and regeneration. The fin comprises 16 to 18 bony rays, each containing multiple joints along its proximodistal axis that give rise to segments. Experimental observations on fin ray growth, regeneration and joint formation have been described, but no unified theory has yet been put forward to explain how growth and joint patterns are controlled. We present a model for the control of fin ray growth during development and regeneration, integrated with a model for joint pattern formation, which is in agreement with published, as well as new, experimental data. We propose that fin ray growth and joint patterning are coordinated through the interaction of three morphogens. When the model is extended to incorporate multiple rays across the fin, it also accounts for how the caudal fin acquires its shape during development, and regains its correct size and shape following amputation.

  17. Increased expression of damage-associated molecular patterns (DAMPs) in osteoarthritis of human knee joint compared to hip joint.

    PubMed

    Rosenberg, John H; Rai, Vikrant; Dilisio, Matthew F; Sekundiak, Todd D; Agrawal, Devendra K

    2017-12-01

    Osteoarthritis (OA) is a degenerative disease characterized by the destruction of cartilage. The greatest risk factors for the development of OA include age and obesity. Recent studies suggest the role of inflammation in the pathogenesis of OA. The two most common locations for OA to occur are in the knee and hip joints. The knee joint experiences more mechanical stress, cartilage degeneration, and inflammation than the hip joint. This could contribute to the increased incidence of OA in the knee joint. Damage-associated molecular patterns (DAMPs), including high-mobility group box-1, receptor for advanced glycation end products, and alarmins (S100A8 and S100A9), are released in the joint in response to stress-mediated chondrocyte and cartilage damage. This facilitates increased cartilage degradation and inflammation in the joint. Studies have documented the role of DAMPs in the pathogenesis of OA; however, the comparison of DAMPs and its influence on OA has not been discussed. In this study, we compared the DAMPs between OA knee and hip joints and found a significant difference in the levels of DAMPs expressed in the knee joint compared to the hip joint. The increased levels of DAMPs suggest a difference in the underlying pathogenesis of OA in the knee and the hip and highlights DAMPs as potential therapeutic targets for OA in the future.

  18. Knee medial and lateral contact forces in a musculoskeletal model with subject-specific contact point trajectories.

    PubMed

    Zeighami, A; Aissaoui, R; Dumas, R

    2018-03-01

    Contact point (CP) trajectory is a crucial parameter in estimating medial/lateral tibio-femoral contact forces from the musculoskeletal (MSK) models. The objective of the present study was to develop a method to incorporate the subject-specific CP trajectories into the MSK model. Ten healthy subjects performed 45 s treadmill gait trials. The subject-specific CP trajectories were constructed on the tibia and femur as a function of extension-flexion using low-dose bi-plane X-ray images during a quasi-static squat. At each extension-flexion position, the tibia and femur CPs were superimposed in the three directions on the medial side, and in the anterior-posterior and proximal-distal directions on the lateral side to form the five kinematic constraints of the knee joint. The Lagrange multipliers associated to these constraints directly yielded the medial/lateral contact forces. The results from the personalized CP trajectory model were compared against the linear CP trajectory and sphere-on-plane CP trajectory models which were adapted from the commonly used MSK models. Changing the CP trajectory had a remarkable impact on the knee kinematics and changed the medial and lateral contact forces by 1.03 BW and 0.65 BW respectively, in certain subjects. The direction and magnitude of the medial/lateral contact force were highly variable among the subjects and the medial-lateral shift of the CPs alone could not determine the increase/decrease pattern of the contact forces. The suggested kinematic constraints are adaptable to the CP trajectories derived from a variety of joint models and those experimentally measured from the 3D imaging techniques. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Contact patterning strategies for 32nm and 28nm technology

    NASA Astrophysics Data System (ADS)

    Morgenfeld, Bradley; Stobert, Ian; An, Ju j.; Kanai, Hideki; Chen, Norman; Aminpur, Massud; Brodsky, Colin; Thomas, Alan

    2011-04-01

    As 193 nm immersion lithography is extended indefinitely to sustain technology roadmaps, there is increasing pressure to contain escalating lithography costs by identifying patterning solutions that can minimize the use of multiple-pass processes. Contact patterning for the 32/28 nm technology nodes has been greatly facilitated by just-in-time introduction of new process enablers that allow the simultaneous support of flexible foundry-oriented ground rules alongside highperformance technology, while also migrating to a single-pass patterning process. The incorporation of device based performance metrics along with rigorous patterning and structural variability studies were critical in the evaluation of material innovation for improved resolution and CD shrink along with novel data preparation flows utilizing aggressive strategies for SRAF insertion and retargeting.

  20. The influence of muscle pennation angle and cross-sectional area on contact forces in the ankle joint

    PubMed Central

    Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan RT

    2016-01-01

    Data about a muscle’s fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep

  1. The influence of muscle pennation angle and cross-sectional area on contact forces in the ankle joint.

    PubMed

    Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan Rt

    2017-01-01

    Data about a muscle's fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep

  2. Reducing contact resistance in graphene devices through contact area patterning.

    PubMed

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  3. The role of obesity, biomechanical constitution of the pelvis and contact joint stress in progression of hip osteoarthritis.

    PubMed

    Recnik, G; Kralj-Iglic, V; Iglic, A; Antolic, V; Kramberger, S; Rigler, I; Pompe, B; Vengust, R

    2009-07-01

    The aim of our study was to explore whether earlier hip arthroplasty for idiopathic osteoarthritis (OA) might be explained by enlarged contact stress in the hip joint, and to what amount can that be attributed to obesity and biomechanical constitution of the pelvis. Fifty subjects were selected from a list of consecutive recipients of hip endoprosthesis due to idiopathic OA; standard pelvic radiographs made years prior to surgery were the main selection criteria. For 65 hips resultant hip force and peak contact hip stress normalized to the body weight (R/Wb and p(max)/Wb) were determined from the radiographs with the HIPSTRESS method. Body weight and body mass index (BMI) were obtained with an interview. Regression analysis was used to correlate parameters of obesity (body weight, BMI), biomechanical constitution of the pelvis (R/Wb, p(max)/Wb) and mechanical loading within the hip joint (R, p(max)) with age at hip arthroplasty. Younger age at hip arthroplasty was associated with higher body weight (P=0.009), higher peak contact hip stress normalized to the body weight - p(max)/Wb (P=0.019), higher resultant hip force -R (P=0.027) and larger peak contact hip stress - p(max) (P<0.001), but not with BMI (P=0.121) or R/Wb (P=0.614). Our results suggest that enlarged contact stress (p(max)) plays an important role in rapid progression of hip OA with both obesity (increased body weight) and unfavorable biomechanical constitution of the pelvis (greater p(max)/Wb) contributing.

  4. Whole-body patterns of the range of joint motion in young adults: masculine type and feminine type.

    PubMed

    Moromizato, Keiichi; Kimura, Ryosuke; Fukase, Hitoshi; Yamaguchi, Kyoko; Ishida, Hajime

    2016-10-01

    Understanding the whole-body patterns of joint flexibility and their related biological and physical factors contributes not only to clinical assessments but also to the fields of human factors and ergonomics. In this study, ranges of motion (ROMs) at limb and trunk joints of young adults were analysed to understand covariation patterns of different joint motions and to identify factors associated with the variation in ROM. Seventy-eight healthy volunteers (42 males and 36 females) living on Okinawa Island, Japan, were recruited. Passive ROM was measured at multiple joints through the whole body (31 measurements) including the left and right side limbs and trunk. Comparisons between males and females, dominant and non-dominant sides, and antagonistic motions indicated that body structures influence ROMs. In principal component analysis (PCA) on the ROM data, the first principal component (PC1) represented the sex difference and a similar covariation pattern appeared in the analysis within each sex. Multiple regression analysis showed that this component was associated with sex, age, body fat %, iliospinale height, and leg extension strength. The present study identified that there is a spectrum of "masculine" and "feminine" types in the whole-body patterns of joint flexibility. This study also suggested that body proportion and composition, muscle mass and strength, and possibly skeletal structures partly explain such patterns. These results would be important to understand individual variation in susceptibility to joint injuries and diseases and in one's suitable and effective postures and motions.

  5. Online respondent-driven sampling for studying contact patterns relevant for the spread of close-contact pathogens: a pilot study in Thailand.

    PubMed

    Stein, Mart L; van Steenbergen, Jim E; Chanyasanha, Charnchudhi; Tipayamongkholgul, Mathuros; Buskens, Vincent; van der Heijden, Peter G M; Sabaiwan, Wasamon; Bengtsson, Linus; Lu, Xin; Thorson, Anna E; Kretzschmar, Mirjam E E

    2014-01-01

    Information on social interactions is needed to understand the spread of airborne infections through a population. Previous studies mostly collected egocentric information of independent respondents with self-reported information about contacts. Respondent-driven sampling (RDS) is a sampling technique allowing respondents to recruit contacts from their social network. We explored the feasibility of webRDS for studying contact patterns relevant for the spread of respiratory pathogens. We developed a webRDS system for facilitating and tracking recruitment by Facebook and email. One-day diary surveys were conducted by applying webRDS among a convenience sample of Thai students. Students were asked to record numbers of contacts at different settings and self-reported influenza-like-illness symptoms, and to recruit four contacts whom they had met in the previous week. Contacts were asked to do the same to create a network tree of socially connected individuals. Correlations between linked individuals were analysed to investigate assortativity within networks. We reached up to 6 waves of contacts of initial respondents, using only non-material incentives. Forty-four (23.0%) of the initially approached students recruited one or more contacts. In total 257 persons participated, of which 168 (65.4%) were recruited by others. Facebook was the most popular recruitment option (45.1%). Strong assortative mixing was seen by age, gender and education, indicating a tendency of respondents to connect to contacts with similar characteristics. Random mixing was seen by reported number of daily contacts. Despite methodological challenges (e.g. clustering among respondents and their contacts), applying RDS provides new insights in mixing patterns relevant for close-contact infections in real-world networks. Such information increases our knowledge of the transmission of respiratory infections within populations and can be used to improve existing modelling approaches. It is worthwhile

  6. Online Respondent-Driven Sampling for Studying Contact Patterns Relevant for the Spread of Close-Contact Pathogens: A Pilot Study in Thailand

    PubMed Central

    Stein, Mart L.; van Steenbergen, Jim E.; Chanyasanha, Charnchudhi; Tipayamongkholgul, Mathuros; Buskens, Vincent; van der Heijden, Peter G. M.; Sabaiwan, Wasamon; Bengtsson, Linus; Lu, Xin; Thorson, Anna E.; Kretzschmar, Mirjam E. E.

    2014-01-01

    Background Information on social interactions is needed to understand the spread of airborne infections through a population. Previous studies mostly collected egocentric information of independent respondents with self-reported information about contacts. Respondent-driven sampling (RDS) is a sampling technique allowing respondents to recruit contacts from their social network. We explored the feasibility of webRDS for studying contact patterns relevant for the spread of respiratory pathogens. Materials and Methods We developed a webRDS system for facilitating and tracking recruitment by Facebook and email. One-day diary surveys were conducted by applying webRDS among a convenience sample of Thai students. Students were asked to record numbers of contacts at different settings and self-reported influenza-like-illness symptoms, and to recruit four contacts whom they had met in the previous week. Contacts were asked to do the same to create a network tree of socially connected individuals. Correlations between linked individuals were analysed to investigate assortativity within networks. Results We reached up to 6 waves of contacts of initial respondents, using only non-material incentives. Forty-four (23.0%) of the initially approached students recruited one or more contacts. In total 257 persons participated, of which 168 (65.4%) were recruited by others. Facebook was the most popular recruitment option (45.1%). Strong assortative mixing was seen by age, gender and education, indicating a tendency of respondents to connect to contacts with similar characteristics. Random mixing was seen by reported number of daily contacts. Conclusions Despite methodological challenges (e.g. clustering among respondents and their contacts), applying RDS provides new insights in mixing patterns relevant for close-contact infections in real-world networks. Such information increases our knowledge of the transmission of respiratory infections within populations and can be used to

  7. Prediction of medial and lateral contact force of the knee joint during normal and turning gait after total knee replacement.

    PubMed

    Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk

    2016-04-01

    The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.

  8. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  9. Fracture patterns at lava-ice contacts on Kokostick Butte, OR, and Mazama Ridge, Mount Rainier, WA: Implications for flow emplacement and cooling histories

    NASA Astrophysics Data System (ADS)

    Lodge, Robert W. D.; Lescinsky, David T.

    2009-09-01

    Cooling lava commonly develop polygonal joints that form equant hexagonal columns. Such fractures are formed by thermal contraction resulting in an isotropic tensional stress regime. However, certain linear cooling fracture patterns observed at some lava-ice contacts do not appear to fit the model for formation of cooling fractures and columns because of their preferred orientations. These fracture types include sheet-like (ladder-like rectangular fracture pattern), intermediate (pseudo-aligned individual column-bounding fractures), and pseudopillow (straight to arcuate fractures with perpendicular secondary fractures caused by water infiltration) fractures that form the edges of multiple columns along a single linear fracture. Despite the relatively common occurrence of these types of fractures at lava-ice contacts, their significance and mode of formation have not been fully explored. This study investigates the stress regimes responsible for producing these unique fractures and their significance for interpreting cooling histories at lava-ice contacts. Data was collected at Kokostick Butte dacite flow at South Sister, OR, and Mazama Ridge andesite flow at Mount Rainier, WA. Both of these lava flows have been interpreted as being emplaced into contact with ice and linear fracture types have been observed on their ice-contacted margins. Two different mechanisms are proposed for the formation of linear fracture networks. One possible mechanism for the formation of linear fracture patterns is marginal bulging. Melting of confining ice walls will create voids into which flowing lava can deform resulting in margin-parallel tension causing margin-perpendicular fractures. If viewed from the ice-wall, these fractures would be steeply dipping, linear fractures. Another possible mechanism for the formation of linear fracture types is gravitational settling. Pure shear during compression and settling can result in a tensional environment with similar consequences as

  10. Reconstruction of equilibrium trajectories and joint stiffness patterns during single-joint voluntary movements under different instructions.

    PubMed

    Latash, M L

    1994-01-01

    A method for reconstructing joint compliant characteristics during voluntary movements was applied to the analysis of oscillatory and unidirectional elbow flexion movements. In different series, the subjects were given one of the following instructions: (1) do not intervene voluntarily; (2) keep the trajectory; (3) in cases of perturbations, return back to the starting position as quickly as possible (only during unidirectional movements). Under the instruction 'keep trajectory', the apparent joint stiffness increased by 50% to 250%. During oscillatory movements, this was accompanied by a decrease in the maximal difference between the actual and equilibrium joint trajectories and, in several cases, led to a change in the phase relation between the two trajectories. The coefficients of correlation between joint torque and angle were very high (commonly, over 0.9) under the 'do not intervene' instruction. They dropped to about 0.6 under the 'keep trajectory' and to about 0.3 under the 'return back' instructions. Under these two instructions, the low values of the coefficients of correlation did not allow reconstruction of segments of equilibrium trajectories and joint stiffness values in all the subjects. The results provide further support for the lambda-version of the equilibrium-point hypothesis and for using the instruction 'do not intervene voluntarily' to obtain reproducible time patterns of the central motor command.

  11. Patterned CoCrMo and Al2 O3 surfaces for reduced free wear debris in artificial joint arthroplasty.

    PubMed

    Tarabolsi, Mohamad; Klassen, Thomas; Mantwill, Frank; Gärtner, Frank; Siegel, Frank; Schulz, Arndt-Peter

    2013-12-01

    Surface wear of corresponding tribological pairings is still a major problem in the application of artificial joint surgery. This study aims at developing wear reduced surfaces to utilize them in total joint arthroplasty. Using a pico-second laser, samples of medical CoCrMo metal alloy and Al2 O3 ceramic were patterned by laser material removal. The subsequent tribological investigations employed a ring-on-disc method. The results showed that those samples with modified surfaces show less mass or volume loss than those with a regular, smooth surface. Using calf serum as lubricating medium, the volume loss of the structured CoCrMo samples was eight times lower than that of regular samples. By structuring Al2 O3 surfaces, the wear volume could be reduced by 4.5 times. The results demonstrate that defined surface channels or pits enable the local sedimentation of wear debris. Thus, the amount of free debris could be reduced. Fewer abrasives in the lubricated so-called three-body-wear between the contact surfaces should result in less surface damage. Apart from direct influences on the wear behavior, less amounts of free debris of artificial joints should also be beneficial for avoiding undesired reactions with the surrounding soft tissues. The results from this study are very promising. Future investigations should involve the use of simulators meeting the natural conditions in the joint and in vivo studies with living organisms. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  12. Model-based guiding pattern synthesis for robust assembly of contact layers using directed self-assembly

    NASA Astrophysics Data System (ADS)

    Mitra, Joydeep; Torres, Andres; Ma, Yuansheng; Pan, David Z.

    2018-01-01

    Directed self-assembly (DSA) has emerged as one of the most compelling next-generation patterning techniques for sub 7 nm via or contact layers. A key issue in enabling DSA as a mainstream patterning technique is the generation of grapho-epitaxy-based guiding pattern (GP) shapes to assemble the contact patterns on target with high fidelity and resolution. Current GP generation is mostly empirical, and limited to a very small number of via configurations. We propose the first model-based GP synthesis algorithm and methodology for on-target and robust DSA, on general via pattern configurations. The final postoptical proximity correction-printed GPs derived from our original synthesized GPs are resilient to process variations and continue to maintain the same DSA fidelity in terms of placement error and target shape.

  13. Potential effect modifiers of the association between physical activity patterns and joint symptoms in middle aged women.

    PubMed

    Peeters, Geeske; Edwards, Kimberley L; Brown, Wendy J; Barker, Anna L; Arden, Nigel; Redmond, Anthony C; Conaghan, Philip G; Cicuttini, Flavia; Mishra, Gita D

    2017-12-06

    To examine whether body mass index (BMI), menopausal status and hormone therapy (HT) use modify the association between physical activity (PA) patterns throughout middle age and incidence and prevalence of joint symptoms in later middle age in women. Data were from 6661 participants (born 1946-1951) in the Australian Longitudinal Study on Women's Health. Surveys were completed every three years from 1998 to 2010 with questions on joint pain and stiffness, PA, height and weight, menopausal symptoms, and HT use. PA patterns were defined as 'none-or-low', 'low-or-meeting-guidelines', 'fluctuating' or 'meeting guidelines-at-all-times' (reference pattern). Logistic regression was used to examine the association between PA patterns and prevalent (in 2010) and cumulative incident (1998-2010) joint symptoms and effect modification by patterns of BMI, menopausal status and HT. The groups representing 'fluctuating' (odds ratio [OR]=1.34, 99% confidence interval [CI]=1.04-1.72) and 'none-or-low' physical activity (OR=1.60, CI =1.08-2.35) had higher odds of incident joint symptoms than those 'meeting guidelines-at-all-times'. Stratification by BMI showed that this association was statistically significant in the obese group only. No evidence was found for effect modification by menopausal status or HT use. The findings were similar for prevalent joint symptoms. Maintaining at least low levels of physical activity throughout middle age was associated with lower prevalence and incidence of joint symptoms in later life. This apparent protective effect of physical activity on joint symptoms was stronger in obese women than in under or normal weight women, and not related to menopause and HT status. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Age- and Sex-Specific Social Contact Patterns and Incidence of Mycobacterium tuberculosis Infection.

    PubMed

    Dodd, Peter J; Looker, Clare; Plumb, Ian D; Bond, Virginia; Schaap, Ab; Shanaube, Kwame; Muyoyeta, Monde; Vynnycky, Emilia; Godfrey-Faussett, Peter; Corbett, Elizabeth L; Beyers, Nulda; Ayles, Helen; White, Richard G

    2016-01-15

    We aimed to model the incidence of infection with Mycobacterium tuberculosis among adults using data on infection incidence in children, disease prevalence in adults, and social contact patterns. We conducted a cross-sectional face-to-face survey of adults in 2011, enumerating "close" (shared conversation) and "casual" (shared indoor space) social contacts in 16 Zambian communities and 8 South African communities. We modeled the incidence of M. tuberculosis infection in all age groups using these contact patterns, as well as the observed incidence of M. tuberculosis infection in children and the prevalence of tuberculosis disease in adults. A total of 3,528 adults participated in the study. The reported rates of close and casual contact were 4.9 per adult per day (95% confidence interval: 4.6, 5.2) and 10.4 per adult per day (95% confidence interval: 9.3, 11.6), respectively. Rates of close contact were higher for adults in larger households and rural areas. There was preferential mixing of close contacts within age groups and within sexes. The estimated incidence of M. tuberculosis infection in adults was 1.5-6 times higher (2.5%-10% per year) than that in children. More than 50% of infections in men, women, and children were estimated to be due to contact with adult men. We conclude that estimates of infection incidence based on surveys in children might underestimate incidence in adults. Most infections may be due to contact with adult men. Treatment and control of tuberculosis in men is critical to protecting men, women, and children from tuberculosis. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  15. Comparison of Contact Patterns Relevant for Transmission of Respiratory Pathogens in Thailand and the Netherlands Using Respondent-Driven Sampling

    PubMed Central

    Stein, Mart L.; van Steenbergen, Jim E.; Buskens, Vincent; van der Heijden, Peter G. M.; Chanyasanha, Charnchudhi; Tipayamongkholgul, Mathuros; Thorson, Anna E.; Bengtsson, Linus; Lu, Xin; Kretzschmar, Mirjam E. E.

    2014-01-01

    Understanding infection dynamics of respiratory diseases requires the identification and quantification of behavioural, social and environmental factors that permit the transmission of these infections between humans. Little empirical information is available about contact patterns within real-world social networks, let alone on differences in these contact networks between populations that differ considerably on a socio-cultural level. Here we compared contact network data that were collected in the Netherlands and Thailand using a similar online respondent-driven method. By asking participants to recruit contact persons we studied network links relevant for the transmission of respiratory infections. We studied correlations between recruiter and recruited contacts to investigate mixing patterns in the observed social network components. In both countries, mixing patterns were assortative by demographic variables and random by total numbers of contacts. However, in Thailand participants reported overall more contacts which resulted in higher effective contact rates. Our findings provide new insights on numbers of contacts and mixing patterns in two different populations. These data could be used to improve parameterisation of mathematical models used to design control strategies. Although the spread of infections through populations depends on more factors, found similarities suggest that spread may be similar in the Netherlands and Thailand. PMID:25423343

  16. Modeling Thermal Contact Resistance

    NASA Technical Reports Server (NTRS)

    Kittel, Peter; Sperans, Joel (Technical Monitor)

    1994-01-01

    One difficulty in using cryocoolers is making good thermal contact between the cooler and the instrument being cooled. The connection is often made through a bolted joint. The temperature drop associated with this joint has been the subject of many experimental and theoretical studies. The low temperature behavior of dry joints have shown some anomalous dependence on the surface condition of the mating parts. There is also some doubts on how well one can extrapolate from the test samples to predicting the performance of a real system. Both finite element and analytic models of a simple contact system have been developed. The model assumes (a) the contact is dry (contact limited to a small portion of the total available area and the spaces in-between the actual contact patches are perfect insulators), (b) contacts are clean (conductivity of the actual contact is the same as the bulk), (c) small temperature gradients (the bulk conductance may be assumed to be temperature independent), (d) the absolute temperature is low (thermal radiation effects are ignored), and (e) the dimensions of the nominal contact area are small compared to the thickness of the bulk material (the contact effects are localized near the contact). The models show that in the limit of actual contact area much less than the nominal area (a much less than A), that the excess temperature drop due to a single point of contact scales as a(exp -1/2). This disturbance only extends a distance approx. A(exp 1/2) into the bulk material. A group of identical contacts will result in an excess temperature drop that scales as n(exp -1/2), where n is the number of contacts and n dot a is constant. This implies that flat rough surfaces will have a lower excess temperature drop than flat polished surfaces.

  17. Daily patterns of communication and contact between Italian early adolescents and their friends.

    PubMed

    Baiocco, Roberto; Laghi, Fiorenzo; Schneider, Barry H; Dalessio, Maria; Amichai-Hamburger, Yair; Coplan, Robert J; Koszycki, Diana; Flament, Martine

    2011-01-01

    The goal of the present study was to explore patterns of communication between adolescents and their friends across both "online" and "in-person" contexts. The participants were adolescents (n = 727) aged 11-16 years attending middle schools in urban and rural areas of Italy. Participants completed daily logs of their in-person and online contacts with friends for 20 consecutive school days. Girls reported more total contacts with their friends than did boys as well as friendships that were closer and more intimate. However, boys indicated more contact than girls via electronic communication and online. Contacts with peers in general were less frequent among the older participants, perhaps because of increasing academic demands. Participants who complemented in-person contact with friends with electronic contact were less lonely than their counterparts who were less versatile in accessing different modalities of making contact with friends.

  18. Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

    PubMed

    Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John

    2013-11-01

    Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.

  19. An equilibrium-point model of electromyographic patterns during single-joint movements based on experimentally reconstructed control signals.

    PubMed

    Latash, M L; Goodman, S R

    1994-01-01

    The purpose of this work has been to develop a model of electromyographic (EMG) patterns during single-joint movements based on a version of the equilibrium-point hypothesis, a method for experimental reconstruction of the joint compliant characteristics, the dual-strategy hypothesis, and a kinematic model of movement trajectory. EMG patterns are considered emergent properties of hypothetical control patterns that are equally affected by the control signals and peripheral feedback reflecting actual movement trajectory. A computer model generated the EMG patterns based on simulated movement kinematics and hypothetical control signals derived from the reconstructed joint compliant characteristics. The model predictions have been compared to published recordings of movement kinematics and EMG patterns in a variety of movement conditions, including movements over different distances, at different speeds, against different-known inertial loads, and in conditions of possible unexpected decrease in the inertial load. Changes in task parameters within the model led to simulated EMG patterns qualitatively similar to the experimentally recorded EMG patterns. The model's predictive power compares it favourably to the existing models of the EMG patterns. Copyright © 1994. Published by Elsevier Ltd.

  20. Multibody dynamic simulation of knee contact mechanics

    PubMed Central

    Bei, Yanhong; Fregly, Benjamin J.

    2006-01-01

    Multibody dynamic musculoskeletal models capable of predicting muscle forces and joint contact pressures simultaneously would be valuable for studying clinical issues related to knee joint degeneration and restoration. Current three-dimensional multi-body knee models are either quasi-static with deformable contact or dynamic with rigid contact. This study proposes a computationally efficient methodology for combining multibody dynamic simulation methods with a deformable contact knee model. The methodology requires preparation of the articular surface geometry, development of efficient methods to calculate distances between contact surfaces, implementation of an efficient contact solver that accounts for the unique characteristics of human joints, and specification of an application programming interface for integration with any multibody dynamic simulation environment. The current implementation accommodates natural or artificial tibiofemoral joint models, small or large strain contact models, and linear or nonlinear material models. Applications are presented for static analysis (via dynamic simulation) of a natural knee model created from MRI and CT data and dynamic simulation of an artificial knee model produced from manufacturer’s CAD data. Small and large strain natural knee static analyses required 1 min of CPU time and predicted similar contact conditions except for peak pressure, which was higher for the large strain model. Linear and nonlinear artificial knee dynamic simulations required 10 min of CPU time and predicted similar contact force and torque but different contact pressures, which were lower for the nonlinear model due to increased contact area. This methodology provides an important step toward the realization of dynamic musculoskeletal models that can predict in vivo knee joint motion and loading simultaneously. PMID:15564115

  1. Investigation of the dependence of joint contact forces on musculotendon parameters using a codified workflow for image-based modelling.

    PubMed

    Modenese, Luca; Montefiori, Erica; Wang, Anqi; Wesarg, Stefan; Viceconti, Marco; Mazzà, Claudia

    2018-05-17

    The generation of subject-specific musculoskeletal models of the lower limb has become a feasible task thanks to improvements in medical imaging technology and musculoskeletal modelling software. Nevertheless, clinical use of these models in paediatric applications is still limited for what concerns the estimation of muscle and joint contact forces. Aiming to improve the current state of the art, a methodology to generate highly personalized subject-specific musculoskeletal models of the lower limb based on magnetic resonance imaging (MRI) scans was codified as a step-by-step procedure and applied to data from eight juvenile individuals. The generated musculoskeletal models were used to simulate 107 gait trials using stereophotogrammetric and force platform data as input. To ensure completeness of the modelling procedure, muscles' architecture needs to be estimated. Four methods to estimate muscles' maximum isometric force and two methods to estimate musculotendon parameters (optimal fiber length and tendon slack length) were assessed and compared, in order to quantify their influence on the models' output. Reported results represent the first comprehensive subject-specific model-based characterization of juvenile gait biomechanics, including profiles of joint kinematics and kinetics, muscle forces and joint contact forces. Our findings suggest that, when musculotendon parameters were linearly scaled from a reference model and the muscle force-length-velocity relationship was accounted for in the simulations, realistic knee contact forces could be estimated and these forces were not sensitive the method used to compute muscle maximum isometric force. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Comparison of pre-contact joint kinematics and vertical impulse between vertical jump landings and step-off landings from equal heights.

    PubMed

    Harry, John R; Freedman Silvernail, Julia; Mercer, John A; Dufek, Janet S

    2017-12-01

    Although impact phase differences between vertical jump landings (VJL) and step-off landings (STL) may be related to task-specific pre-contact strategies, pre-contact mechanics are rarely examined. Thus, pre-contact kinematics and vertical ground reaction force (vGRF) impulse were examined between VJL and STL. Ten health adults (20.9 ± 1.6 yrs; 167.8 ± 4.2 cm; 68.5 ± 7.15 kg) performed 15 VJL and 15 STL from equal heights. Limb (lead; trail) by task (VJL; STL) ANOVAs (α = 0.05) compared hip, knee, and ankle joint angles 150 ms pre-contact, 100 ms pre-contact, 50 ms pre-contact, and at ground contact. Joint angular displacement was also evaluated between 150 ms pre-contact and ground contact. vGRF impulse was compared during the loading (ground contact to peak vGRF) and attenuation (peak vGRF to end of impact) phases. Greater hip flexion angles occurred during STL versus VJL at each event except 150 ms pre-contact (p ≤ .004). Trail limb knee flexion angles were greater at each event when compared to the lead limb during STL (p ≤ .019). Greater trail limb knee flexion angles occurred during STL versus VJL at all four events (p ≤ .018), while greater plantarflexion angles occurred at all four events during VJL versus STL (p ≤ .034). During STL, greater trail limb plantarflexion angles were detected at each event versus the lead limb (p < .001). Lesser hip, lead and trail limb knee displacement occurred during STL versus VJL (p < .05). Greater vGRF impulse was detected during the loading phase of VJL (<.001), while greater vGRF impulse occurred during the attenuation phase of STL (p = .025). These tasks are characterized by distinct pre-contact kinematic strategies and post-contact kinetics. The task utilized in practice should reflect the requirements of the population of interest. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. A New Sensor for Measurement of Dynamic Contact Stress in the Hip

    PubMed Central

    Rudert, M. J.; Ellis, B. J.; Henak, C. R.; Stroud, N. J.; Pederson, D. R.; Weiss, J. A.; Brown, T. D.

    2014-01-01

    Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential “ring-and-spoke” sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26

  4. A new sensor for measurement of dynamic contact stress in the hip.

    PubMed

    Rudert, M J; Ellis, B J; Henak, C R; Stroud, N J; Pederson, D R; Weiss, J A; Brown, T D

    2014-03-01

    Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shoulder, ankle, wrist, and spinal facet joints. Until now, however, no such sensor had been available for the human hip joint due to difficulties posed by the deep, bi-curvilinear geometry of the acetabulum. We report here the design and development of a novel sensor capable of measuring dynamic contact stress in human cadaveric hip joints (maximum contact stress of 20 MPa and maximum sampling rate 100 readings/s). Particular emphasis is placed on issues concerning calibration, and on the effect of joint curvature on the sensor's performance. The active pressure-sensing regions of the sensors have the shape of a segment of an annulus with a 150-deg circumferential span, and employ a polar/circumferential "ring-and-spoke" sensel grid layout. There are two sensor sizes, having outside radii of 44 and 48 mm, respectively. The new design was evaluated in human cadaver hip joints using two methods. The stress magnitudes and spatial distribution measured by the sensor were compared to contact stresses measured by pressure sensitive film during static loading conditions that simulated heel strike during walking and stair climbing. Additionally, the forces obtained by spatial integration of the sensor contact stresses were compared to the forces measured by load cells during the static simulations and for loading applied by a dynamic hip simulator. Stress magnitudes and spatial distribution patterns obtained from the sensor versus from pressure sensitive film exhibited good agreement. The joint forces obtained during both static and dynamic loading were within ±10% and ±26

  5. Hierarchical micro- and nanofabrication by pattern-directed contact instabilities of thin viscoelastic films

    NASA Astrophysics Data System (ADS)

    Ghosh, Abir; Bandyopadhyay, Dipankar; Sarkar, Jayati; Sharma, Ashutosh

    2017-12-01

    A surface of a thin viscoelastic film forms spinodal patterns when brought in contact proximity of another surface due to the dominance of destabilizing intermolecular interaction over the stabilizing elastic and surface tension forces. In this study, we theoretically explore such contact instabilities of a thin viscoelastic film, wherein the patterns generated on the surface of the film is developed with the help of a contactor decorated with periodic physical, chemical, and physicochemical features on the surface. The nonlinear analysis shown here considers the movement of the patterned contactor during the adhesion and debonding processes, which is unlike most of the previous works where the contactor is considered to be stationary. The simulations reveal that the amplitude and periodicity of the patterns decorated on the contactor together with the contactor speed can be the key parameters to stimulate pattern formation on the film surface alongside causing changeover of the various modes of debonding of the surfaces. In particular, the ratio of the elastic to viscous compliances of the film is found to play a critical role to stimulate the changeover of the modes from catastrophic to peeling or coalescence. The study uncovers that a higher wettability contrast across the patterned contactor leads to the catastrophic collapse of the patterns decorated on the film surface when the contactor debonds at a moderate speed. In comparison, a moderately high wettability contrast alongside a faster withdrawal speed of the contactor results in the gradual peeling of columns during the debonding cycle. Remarkably, a higher withdrawal speed of the contactor from the film-proximity can increase the aspect ratio of the patterns fabricated on the film surface to about fourfold during the peeling mode of debonding. The results show the importance of the usage of patterned contactors, their controlled movement, and extent of elastic to viscous compliance ratio of the film for

  6. Novel patterning of CdS / CdTe thin film with back contacts for photovoltaic application

    NASA Astrophysics Data System (ADS)

    Ilango, Murugaiya Sridar; Ramasesha, Sheela K.

    2018-04-01

    The heterostructure of patterned CdS / CdTe thin films with back contact have been devised with electron beam lithography and fabricated using sputter deposition technique. The metallic contacts for n-CdS and p-CdTe are patterned such that both are placed at the bottom of the cell. This avoids losses due to contact shading and increases absorption in the window layer. Patterning of the device surface helps in increasing the junction area which can modulate the absorption of more number of photons due to total internal reflection. Computing the surface area between a planar and a patterned device has revealed 133% increase in the junction area. The physical and optical properties of the sputter-deposited CdS / CdTe layers are also presented. J- V characteristics of the solar cell showed the fill factor to be 25.9%, open circuit voltage to be 17 mV and short-circuit current density to be 113.68 A/m2. The increase in surface area is directly related to the increase in the short circuit current of the photovoltaic cell, which is observed from the results of simulated model in Atlas / Silvaco.

  7. Improved Electrical Contact For Dowhhole Drilling Networks

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Dahlgren, Scott; Fox, Joe; Sneddon, Cameron

    2005-08-16

    An electrical contact system for transmitting information across tool joints while minimizing signal reflections that occur at the tool joints includes a first electrical contact comprising an annular resilient material. An annular conductor is embedded within the annular resilient material and has a surface exposed from the annular resilient material. A second electrical contact is provided that is substantially equal to the first electrical contact. Likewise, the second electrical contact has an annular resilient material and an annular conductor. The two electrical contacts configured to contact one another such that the annular conductors of each come into physical contact. The annular resilient materials of each electrical contact each have dielectric characteristics and dimensions that are adjusted to provide desired impedance to the electrical contacts.

  8. Joint Chiefs of Staff > Media

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Media News Videos Chairman's

  9. In vitro assessment of the contact mechanics of reverse-engineered distal humeral hemiarthroplasty prostheses.

    PubMed

    Willing, Ryan; Lapner, Michael; King, Graham J W; Johnson, James A

    2014-11-01

    Distal humeral hemiarthroplasty alters cartilage contact mechanics, which may predispose to osteoarthritis. Current prostheses do not replicate the native anatomy, and therefore contribute to these changes. We hypothesized that prostheses reverse-engineered from the native bone shape would provide similar contact patterns as the native articulation. Reverse-engineered hemiarthroplasty prostheses were manufactured for five cadaveric elbows based on CT images of the distal humerus. Passive flexion trials with constant muscle forces were performed with the native articulation intact while bone motions were recorded using a motion tracking system. Motion trials were then repeated after the distal humerus was replaced with a corresponding reverse-engineered prosthesis. Contact areas and patterns were reconstructed using computer models created from CT scan images combined with the motion tracker data. The total contact areas, as well as the contact area within smaller sub-regions of the ulna and radius, were analyzed for changes resulting from hemiarthroplasty using repeated-measures ANOVAs. Contact area at the ulna and radius decreased on average 42% (SD 19%, P=.008) and 41% (SD 42%, P=.096), respectively. Contact area decreases were not uniform throughout the different sub-regions, suggesting that contact patterns were also altered. Reverse-engineered prostheses did not reproduce the same contact pattern as the native joints, possibly because the thickness of the distal humerus cartilage layer was neglected when generating the prosthesis shapes or as a consequence of the increased stiffness of the metallic implants. Alternative design strategies and materials for hemiarthroplasty should be considered in future work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Information content of contact-pattern representations and predictability of epidemic outbreaks

    PubMed Central

    Holme, Petter

    2015-01-01

    To understand the contact patterns of a population—who is in contact with whom, and when the contacts happen—is crucial for modeling outbreaks of infectious disease. Traditional theoretical epidemiology assumes that any individual can meet any with equal probability. A more modern approach, network epidemiology, assumes people are connected into a static network over which the disease spreads. Newer yet, temporal network epidemiology, includes the time in the contact representations. In this paper, we investigate the effect of these successive inclusions of more information. Using empirical proximity data, we study both outbreak sizes from unknown sources, and from known states of ongoing outbreaks. In the first case, there are large differences going from a fully mixed simulation to a network, and from a network to a temporal network. In the second case, differences are smaller. We interpret these observations in terms of the temporal network structure of the data sets. For example, a fast overturn of nodes and links seem to make the temporal information more important. PMID:26403504

  11. Stress Behaviour in Compression of Contact-Monolithic Joint of Self-Supporting Wall of Large Panel Multi-Storey Building

    NASA Astrophysics Data System (ADS)

    Derbentsev, I.; Karyakin, A. A.; Volodin, A.

    2017-11-01

    The article deals with the behaviour of a contact-monolithic joint of large-panel buildings under compression. It gives a detailed analysis and the descriptions of the stages of such joints failure based on the results of the tests and computational modelling. The article is of interest to specialists who deal with computational modelling or the research of large-panel multi-storey buildings. The text gives a valuable information on the values of their bearing capacity and flexibility, the eccentricity of load transfer from upper panel to lower, the value of thrust passed to a ceiling panel. Recommendations are given to estimate all the above-listed parameters.

  12. Toward patient-specific articular contact mechanics

    PubMed Central

    Ateshian, Gerard A.; Henak, Corinne R.; Weiss, Jeffrey A.

    2015-01-01

    The mechanics of contacting cartilage layers is fundamentally important to understanding the development, homeostasis and pathology of diarthrodial joints. Because of the highly nonlinear nature of both the materials and the contact problem itself, numerical methods such as the finite element method are typically incorporated to obtain solutions. Over the course of five decades, we have moved from an initial qualitative understanding of articular cartilage material behavior to the ability to perform complex, three-dimensional contact analysis, including multiphasic material representations. This history includes the development of analytical and computational contact analysis methods that now provide the ability to perform highly nonlinear analyses. Numerical implementations of contact analysis based on the finite element method are rapidly advancing and will soon enable patient-specific analysis of joint contact mechanics using models based on medical image data. In addition to contact stress on the articular surfaces, these techniques can predict variations in strain and strain through the cartilage layers, providing the basis to predict damage and failure. This opens up exciting areas for future research and application to patient-specific diagnosis and treatment planning applied to a variety of pathologies that affect joint function and cartilage homeostasis. PMID:25698236

  13. [Finite element analysis on the effect of lateral wedge insole intervention on the contact characteristics of the subtalar joint].

    PubMed

    Zhou, En-Chang; Tang, Ping; Zhu, Chuan-Ying; Liu, Shi-Ming

    2017-01-25

    To establish a three-dimensional finite element model of the lower limb bones, and investigate the changes of the contact characteristics of the subtalar joint after using laterally wedge insole intervention. Using the reverse modeling technology, the lower limb bones of normal adult volunteers was scanned by CT. Mimics 10.0 and Geomagic Studio 6.0 software were used to reconstruct the 3D morphology of bones and external soft tissue of the feet. The laterally wedge insole was designed in ProE 5.0. And then all the models were imported into Hyperwork 10.0 and meshed, and given the material properties. The finite element analysis was carried out in ABAQUS 6.9. A three-dimensional finite element model of the lower extremity was established, which was consisted of 95 365 nodes and 246 238 elements. The contact area of the standing state of the lower joint was larger than that of the anterior middle joint surface. The peak stress was concentrated in the anterior lateral part of the posterior articular surface, and the average stress value was(3.85±1.03) MPa. Compared with the model of 0°, the contact area of the subtalar joint was reduced accordingly. There was a significant correlation between anterior middle joint | r |=0.964, P =0.008, and posterior articular | r |=0.978, P =0.002. The equivalent stress of 0° model distributed from(3.07±1.14) MPa to(3.85± 1.03) MPa, which had no statistically difference. Compared with the 0° model, the equivalent stress of the anterior and middle joint surfaces of the 8° model was significantly reduced( P <0.05), but the peak stress of the posterior articular surface was significantly increased( P <0.05). In the 12° model, the peak stress was sharply increased to(10.51±3.53) MPa. Compared with 8° model, there was no statistically difference( P <0.05). Although the peak stress was slightly increased in 16° model, but compared with 12° model, there was no statistically differences( P >0.05). Although a certain valgus can be

  14. How tibiofemoral alignment and contact locations affect predictions of medial and lateral tibiofemoral contact forces.

    PubMed

    Lerner, Zachary F; DeMers, Matthew S; Delp, Scott L; Browning, Raymond C

    2015-02-26

    Understanding degeneration of biological and prosthetic knee joints requires knowledge of the in-vivo loading environment during activities of daily living. Musculoskeletal models can estimate medial/lateral tibiofemoral compartment contact forces, yet anthropometric differences between individuals make accurate predictions challenging. We developed a full-body OpenSim musculoskeletal model with a knee joint that incorporates subject-specific tibiofemoral alignment (i.e. knee varus-valgus) and geometry (i.e. contact locations). We tested the accuracy of our model and determined the importance of these subject-specific parameters by comparing estimated to measured medial and lateral contact forces during walking in an individual with an instrumented knee replacement and post-operative genu valgum (6°). The errors in the predictions of the first peak medial and lateral contact force were 12.4% and 11.9%, respectively, for a model with subject-specific tibiofemoral alignment and contact locations determined through radiographic analysis, vs. 63.1% and 42.0%, respectively, for a model with generic parameters. We found that each degree of tibiofemoral alignment deviation altered the first peak medial compartment contact force by 51N (r(2)=0.99), while each millimeter of medial-lateral translation of the compartment contact point locations altered the first peak medial compartment contact force by 41N (r(2)=0.99). The model, available at www.simtk.org/home/med-lat-knee/, enables the specification of subject-specific joint alignment and compartment contact locations to more accurately estimate medial and lateral tibiofemoral contact forces in individuals with non-neutral alignment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. How Tibiofemoral Alignment and Contact Locations Affect Predictions of Medial and Lateral Tibiofemoral Contact Forces

    PubMed Central

    Lerner, Zachary F.; DeMers, Matthew S.; Delp, Scott L.; Browning, Raymond C.

    2015-01-01

    Understanding degeneration of biological and prosthetic knee joints requires knowledge of the in-vivo loading environment during activities of daily living. Musculoskeletal models can estimate medial/lateral tibiofemoral compartment contact forces, yet anthropometric differences between individuals make accurate predictions challenging. We developed a full-body OpenSim musculoskeletal model with a knee joint that incorporates subject-specific tibiofemoral alignment (i.e. knee varus-valgus) and geometry (i.e. contact locations). We tested the accuracy of our model and determined the importance of these subject-specific parameters by comparing estimated to measured medial and lateral contact forces during walking in an individual with an instrumented knee replacement and post-operative genu valgum (6°). The errors in the predictions of the first peak medial and lateral contact force were 12.4% and 11.9%, respectively, for a model with subject-specific tibiofemoral alignment and contact locations determined via radiographic analysis, vs. 63.1% and 42.0%, respectively, for a model with generic parameters. We found that each degree of tibiofemoral alignment deviation altered the first peak medial compartment contact force by 51N (r2=0.99), while each millimeter of medial-lateral translation of the compartment contact point locations altered the first peak medial compartment contact force by 41N (r2=0.99). The model, available at www.simtk.org/home/med-lat-knee/, enables the specification of subject-specific joint alignment and compartment contact locations to more accurately estimate medial and lateral tibiofemoral contact forces in individuals with non-neutral alignment. PMID:25595425

  16. Electropalatographic Assessment of Tongue-to-Palate Contact Patterns and Variability in Children, Adolescents, and Adults

    ERIC Educational Resources Information Center

    Cheng, Hei Yan; Murdoch, Bruce E.; Goozee, Justine V.; Scott, Dion

    2007-01-01

    Purpose: To investigate the developmental time course of tongue-to-palate contact patterns during speech from childhood to adulthood using electropalatography (EPG) and a comprehensive profile of data analysis. Method: Tongue-to-palate contacts were recorded during productions of /t/, /l/, /s/, and /k/ in 48 children, adolescents and adults (aged…

  17. Effects of medial meniscus posterior horn avulsion and repair on tibiofemoral contact area and peak contact pressure with clinical implications.

    PubMed

    Marzo, John M; Gurske-DePerio, Jennifer

    2009-01-01

    Avulsion of the posterior horn attachment of the medial meniscus can compromise load-bearing ability, produce meniscus extrusion, and result in tibiofemoral joint-space narrowing, articular cartilage damage, and osteoarthritis. Avulsion of the posterior horn of the medial meniscus will increase peak contact pressure and decrease contact area in the medial compartment of the knee, and posterior horn repair will restore contact area and peak contact pressures to values of the control knee. Controlled laboratory study. Eight fresh-frozen human cadaveric knees had tibiofemoral peak contact pressures and contact area measured in the control state. The posterior horn of the medial meniscus was avulsed from its insertion and knees were retested. The meniscal avulsion was repaired by suture through a transosseous tunnel and the knees were tested a third time. Avulsion of the posterior horn attachment of the medial meniscus resulted in a significant increase in medial joint peak contact pressure (from 3841 kPa to 5084 kPa) and a significant decrease in contact area (from 594 mm(2) to 474 mm(2)). Repair of the avulsion resulted in restoration of the loading profiles to values equal to the control knee, with values of 3551 kPa for peak pressure and 592 mm(2) for contact area. Posterior horn medial meniscal root avulsion leads to deleterious alteration of the loading profiles of the medial joint compartment and results in loss of hoop stress resistance, meniscus extrusion, abnormal loading of the joint, and early knee medial-compartment degenerative changes. The repair technique described restores the ability of the medial meniscus to absorb hoop stress and eliminate joint-space narrowing, possibly decreasing the risk of degenerative disease.

  18. Short-term changes in running mechanics and foot strike pattern after introduction to minimalistic footwear.

    PubMed

    Willson, John D; Bjorhus, Jordan S; Williams, D S Blaise; Butler, Robert J; Porcari, John P; Kernozek, Thomas W

    2014-01-01

    Minimalistic footwear has garnered widespread interest in the running community, based largely on the premise that the footwear may reduce certain running-related injury risk factors through adaptations in running mechanics and foot strike pattern. To examine short-term adaptations in running mechanics among runners who typically run in conventional cushioned heel running shoes as they transition to minimalistic footwear. A 2-week, prospective, observational study. A movement science laboratory. Nineteen female runners with a rear foot strike (RFS) pattern who usually train in conventional running shoes. The participants trained for 20 minutes, 3 times per week for 2 weeks by using minimalistic footwear. Three-dimensional lower extremity running mechanics were analyzed before and after this 2-week period. Hip, knee, and ankle joint kinematics at initial contact; step length; stance time; peak ankle joint moment and joint work; impact peak; vertical ground reaction force loading rate; and foot strike pattern preference were evaluated before and after the intervention. The knee flexion angle at initial contact increased 3.8° (P < .01), but the ankle and hip flexion angles at initial contact did not change after training. No changes in ankle joint kinetics or running temporospatial parameters were observed. The majority of participants (71%), before the intervention, demonstrated an RFS pattern while running in minimalistic footwear. The proportion of runners with an RFS pattern did not decrease after 2 weeks (P = .25). Those runners who chose an RFS pattern in minimalistic shoes experienced a vertical loading rate that was 3 times greater than those who chose to run with a non-RFS pattern. Few systematic changes in running mechanics were observed among participants after 2 weeks of training in minimalistic footwear. The majority of the participants continued to use an RFS pattern after training in minimalistic footwear, and these participants experienced higher

  19. Prevalence and pattern of glenohumeral injuries among acute high-grade acromioclavicular joint instabilities.

    PubMed

    Pauly, Stephan; Kraus, Natascha; Greiner, Stefan; Scheibel, Markus

    2013-06-01

    With increasing numbers of arthroscopically assisted acromioclavicular (AC) joint stabilization procedures has come an increase in reports of concomitant glenohumeral injuries among AC joint separations. The aim of the present study was to evaluate the prevalence, pattern, and cause of glenohumeral pathologies among a large patient population with acute high-grade AC joint instability. A total of 125 patients (13 women, 112 men) with high-grade AC joint dislocation (6 Rockwood II; 119 Rockwood V) underwent diagnostic glenohumeral arthroscopy before AC joint repair. Pathologic lesions were evaluated for acute or degenerative origin and, if considered relevant, treated all-arthroscopically. Concomitant glenohumeral pathologies were found in 38 of 125 patients (30.4%). Analysis of pathogenesis distinguished different patterns of accompanying injuries: acute intra-articular lesions, related to the recent shoulder trauma, were found in 9 patients (7.2%), degenerative lesions, considered to be unrelated to the recent trauma, were found in 18 (14.4%), and 11 (8.8%) had an unclear traumatic correlation (intermediate group). Within the acute and the degenerative group, affected structures were predominantly partial, articular-sided tears of the anterosuperior rotator cuff, including instabilities of the pulley complex, followed by pathologies of the long head of the biceps and superior labrum anteroposterior lesions. The intermediate group presented mainly with articular-sided partial tears of the subscapularis tendon. This prospective study showed a high prevalence (30%) of concomitant glenohumeral pathologies, of which some indicate additional surgical therapy and could be missed by an isolated open AC repair. Hence, the arthroscopic approach for AC joint stabilization allows for the diagnosis and treatment of associated intra-articular pathologies. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  20. Group-level spatio-temporal pattern recovery in MEG decoding using multi-task joint feature learning.

    PubMed

    Kia, Seyed Mostafa; Pedregosa, Fabian; Blumenthal, Anna; Passerini, Andrea

    2017-06-15

    The use of machine learning models to discriminate between patterns of neural activity has become in recent years a standard analysis approach in neuroimaging studies. Whenever these models are linear, the estimated parameters can be visualized in the form of brain maps which can aid in understanding how brain activity in space and time underlies a cognitive function. However, the recovered brain maps often suffer from lack of interpretability, especially in group analysis of multi-subject data. To facilitate the application of brain decoding in group-level analysis, we present an application of multi-task joint feature learning for group-level multivariate pattern recovery in single-trial magnetoencephalography (MEG) decoding. The proposed method allows for recovering sparse yet consistent patterns across different subjects, and therefore enhances the interpretability of the decoding model. Our experimental results demonstrate that the mutli-task joint feature learning framework is capable of recovering more meaningful patterns of varying spatio-temporally distributed brain activity across individuals while still maintaining excellent generalization performance. We compare the performance of the multi-task joint feature learning in terms of generalization, reproducibility, and quality of pattern recovery against traditional single-subject and pooling approaches on both simulated and real MEG datasets. These results can facilitate the usage of brain decoding for the characterization of fine-level distinctive patterns in group-level inference. Considering the importance of group-level analysis, the proposed approach can provide a methodological shift towards more interpretable brain decoding models. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Changes in foot and shank coupling due to alterations in foot strike pattern during running.

    PubMed

    Pohl, Michael B; Buckley, John G

    2008-03-01

    Determining if and how the kinematic relationship between adjacent body segments changes when an individual's gait pattern is experimentally manipulated can yield insight into the robustness of the kinematic coupling across the associated joint(s). The aim of this study was to assess the effects on the kinematic coupling between the forefoot, rearfoot and shank during ground contact of running with alteration in foot strike pattern. Twelve subjects ran over-ground using three different foot strike patterns (heel strike, forefoot strike, toe running). Kinematic data were collected of the forefoot, rearfoot and shank, which were modelled as rigid segments. Coupling at the ankle-complex and midfoot joints was assessed using cross-correlation and vector coding techniques. In general good coupling was found between rearfoot frontal plane motion and transverse plane shank rotation regardless of foot strike pattern. Forefoot motion was also strongly coupled with rearfoot frontal plane motion. Subtle differences were noted in the amount of rearfoot eversion transferred into shank internal rotation in the first 10-15% of stance during heel strike running compared to forefoot and toe running, and this was accompanied by small alterations in forefoot kinematics. These findings indicate that during ground contact in running there is strong coupling between the rearfoot and shank via the action of the joints in the ankle-complex. In addition, there was good coupling of both sagittal and transverse plane forefoot with rearfoot frontal plane motion via the action of the midfoot joints.

  2. Joint Chiefs of Staff > Leadership

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Joint Staff Organizational Chart Joint Chiefs of Staff Links Home Today in DOD About DOD Top Issues News Photos/Videos

  3. More Feedback Is Better than Less: Learning a Novel Upper Limb Joint Coordination Pattern with Augmented Auditory Feedback

    PubMed Central

    Fujii, Shinya; Lulic, Tea; Chen, Joyce L.

    2016-01-01

    Motor learning is a process whereby the acquisition of new skills occurs with practice, and can be influenced by the provision of feedback. An important question is what frequency of feedback facilitates motor learning. The guidance hypothesis assumes that the provision of less augmented feedback is better than more because a learner can use his/her own inherent feedback. However, it is unclear whether this hypothesis holds true for all types of augmented feedback, including for example sonified information about performance. Thus, we aimed to test what frequency of augmented sonified feedback facilitates the motor learning of a novel joint coordination pattern. Twenty healthy volunteers first reached to a target with their arm (baseline phase). We manipulated this baseline kinematic data for each individual to create a novel target joint coordination pattern. Participants then practiced to learn the novel target joint coordination pattern, receiving either feedback on every trial i.e., 100% feedback (n = 10), or every other trial, i.e., 50% feedback (n = 10; acquisition phase). We created a sonification system to provide the feedback. This feedback was a pure tone that varied in intensity in proportion to the error of the performed joint coordination relative to the target pattern. Thus, the auditory feedback contained information about performance in real-time (i.e., “concurrent, knowledge of performance feedback”). Participants performed the novel joint coordination pattern with no-feedback immediately after the acquisition phase (immediate retention phase), and on the next day (delayed retention phase). The root-mean squared error (RMSE) and variable error (VE) of joint coordination were significantly reduced during the acquisition phase in both 100 and 50% feedback groups. There was no significant difference in VE between the groups at immediate and delayed retention phases. However, at both these retention phases, the 100% feedback group showed

  4. Are the Kinematics of the Knee Joint Altered during the Loading Response Phase of Gait in Individuals with Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-ray Study

    PubMed Central

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B.; Klatt, Brian A.; Fitzgerald, G. Kelley

    2011-01-01

    Background Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional declines in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Methods Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Findings Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P < 0.01), while the total abduction/adduction range of motion was increased (P < 0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P < 0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. Interpretations The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. PMID:22071429

  5. BIOMECHANICS AND PATHOMECHANICS OF THE PATELLOFEMORAL JOINT

    PubMed Central

    2016-01-01

    The patellofemoral joint is a joint that can be an area of concern for athletes of various sports and ages. The joint is somewhat complex with multiple contact points and numerous tissues that attach to the patella. Joint forces are variable and depend on the degree of knee flexion and whether the foot is in contact with the ground. The sports medicine specialist must have a good working knowledge of the anatomy and biomechanics of the patellofemoral joint in order to treat it effectively. PMID:27904787

  6. Dynamic Analysis of the Abnormal Isometric Strength Movement Pattern between Shoulder and Elbow Joint in Patients with Hemiplegia.

    PubMed

    Liu, Yali; Hong, Yuezhen; Ji, Linhong

    2018-01-01

    Patients with hemiplegia usually have weak muscle selectivity and usually perform strength at a secondary joint (secondary strength) during performing a strength at one joint (primary strength). The abnormal strength pattern between shoulder and elbow joint has been analyzed by the maximum value while the performing process with strength changing from 0 to maximum then to 0 was a dynamic process. The objective of this study was to develop a method to dynamically analyze the strength changing process. Ten patients were asked to perform four group asks (maximum and 50% maximum voluntary strength in shoulder abduction, shoulder adduction, elbow flexion, and elbow extension). Strength and activities from seven muscles were measured. The changes of secondary strength had significant correlation with those of primary strength in all tasks ( R > 0.76, p < 0.01). The antagonistic muscles were moderately influenced by the primary strength ( R > 0.4, p < 0.01). Deltoid muscles, biceps brachii, triceps brachii, and brachioradialis had significant influences on the abnormal strength pattern (all p < 0.01). The dynamic method was proved to be efficient to analyze the different influences of muscles on the abnormal strength pattern. The muscles, deltoid muscles, biceps brachii, triceps brachii, and brachioradialis, much influenced the stereotyped movement pattern between shoulder and elbow joint.

  7. Dynamic Analysis of the Abnormal Isometric Strength Movement Pattern between Shoulder and Elbow Joint in Patients with Hemiplegia

    PubMed Central

    2018-01-01

    Patients with hemiplegia usually have weak muscle selectivity and usually perform strength at a secondary joint (secondary strength) during performing a strength at one joint (primary strength). The abnormal strength pattern between shoulder and elbow joint has been analyzed by the maximum value while the performing process with strength changing from 0 to maximum then to 0 was a dynamic process. The objective of this study was to develop a method to dynamically analyze the strength changing process. Ten patients were asked to perform four group asks (maximum and 50% maximum voluntary strength in shoulder abduction, shoulder adduction, elbow flexion, and elbow extension). Strength and activities from seven muscles were measured. The changes of secondary strength had significant correlation with those of primary strength in all tasks (R > 0.76, p < 0.01). The antagonistic muscles were moderately influenced by the primary strength (R > 0.4, p < 0.01). Deltoid muscles, biceps brachii, triceps brachii, and brachioradialis had significant influences on the abnormal strength pattern (all p < 0.01). The dynamic method was proved to be efficient to analyze the different influences of muscles on the abnormal strength pattern. The muscles, deltoid muscles, biceps brachii, triceps brachii, and brachioradialis, much influenced the stereotyped movement pattern between shoulder and elbow joint. PMID:29610654

  8. Projecting social contact matrices in 152 countries using contact surveys and demographic data.

    PubMed

    Prem, Kiesha; Cook, Alex R; Jit, Mark

    2017-09-01

    Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school), and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for societies for which

  9. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  10. Knee contact forces and lower extremity support moments during running in young individuals post-partial meniscectomy.

    PubMed

    Willy, R W; Bigelow, M A; Kolesar, A; Willson, J D; Thomas, J S

    2017-01-01

    While partial meniscectomy results in a compromised tibiofemoral joint, little is known regarding tibiofemoral joint loading during running in individuals who are post-partial meniscectomy. It was hypothesized that individuals post-partial meniscectomy would run with a greater hip support moment, yielding reduced peak knee extension moments and reduced tibiofemoral joint contact forces. 3-D Treadmill running mechanics were evaluated in 23 athletic individuals post-partial meniscectomy (37.5 ± 19.0 months post-partial meniscectomy) and 23 matched controls. Bilateral hip, knee and ankle contributions to the total support moment and the peak knee extension moment were calculated. A musculoskeletal model estimated peak and impulse tibiofemoral joint contact forces. Knee function was quantified with the Knee injury and Osteoarthritis Outcome Score (KOOS). During running, the partial meniscectomy group had a greater hip support moment (p = 0.002) and a reduced knee support moment (p < 0.001) relative to the total support moment. This movement pattern was associated with a 14.5 % reduction (p = 0.019) in the peak knee extension moment. Despite these differences, there were no significant group differences in peak or impulse tibiofemoral joint contact forces. Lower KOOS Quality of Life scores were associated with greater hip support moment (p = 0.004, r = -0.58), reduced knee support moment (p = 0.006, r = 0.55) and reduced peak knee extension moment (p = 0.01, r = 0.52). Disordered running mechanics are present long term post-partial meniscectomy. A coordination strategy that shifts a proportion of the total support moment away from the knee to the hip reduces the peak knee extension moment, but does not equate to reduced tibiofemoral joint contact forces during running in individuals post-partial meniscectomy. III.

  11. Patterns of between-farm contacts via professionals in Sweden.

    PubMed

    Olofsson, Emelie; Nöremark, Maria; Lewerin, Susanna Sternberg

    2014-11-04

    Infectious diseases of livestock have negative consequences for animal production as well as animal health and welfare and can be transmitted between farms via direct (live animal movements) as well as indirect (via physical vectors such as, people, transport vehicles and fomites) contacts. The objective of the study was to examine the travel patterns of professionals visiting Swedish farms (veterinarians, milk tanker drivers, artificial inseminators, maintenance technicians and livestock hauliers). This was done by obtaining records of the farms visited by a sample of professionals in the above categories in one week in January, one week in April, one week in July and one week in October in the Swedish counties Västerbotten, Södermanland, Västergötland and Skåne. There were twelve participating organisations, and data was provided for one to three individuals/vehicles/veterinary practices per professional category and per geographic region (except for dairy service technicians and livestock hauliers who did not provide data from all regions). There was a trend towards larger areas covered and smaller number of farms visited per week in the north, but exceptions occurred and there were regional variations. Generally, the greatest areas were travelled by milk tankers and livestock hauliers, and the profession travelling over the smallest areas tended to be the veterinarians. Milk tankers visited most farms per week, one milk tanker could visit between 23 and 90 farms per week and travel over areas between 717 km² and 23,512 km² per week. Valuable insight into the travel patterns of Swedish professionals has emerged although the implications of the study largely concern highly infectious diseases. Movement of live animals pose the greatest risk for the spread of infectious animal diseases; however indirect contacts are important for many diseases. The results of this study indicate that in Sweden a highly contagious disease might spread over a large area in

  12. Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

    PubMed

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B; Klatt, Brian A; Fitzgerald, G Kelley

    2012-05-01

    Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional decline in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P<0.01), while the total abduction/adduction range of motion was increased (P<0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P<0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. EFFECT OF HEEL LIFTS ON PATELLOFEMORAL JOINT STRESS DURING RUNNING.

    PubMed

    Mestelle, Zachary; Kernozek, Thomas; Adkins, Kelly S; Miller, Jessica; Gheidi, Naghmeh

    2017-10-01

    Patellofemoral pain is a debilitating injury for many recreational runners. Excessive patellofemoral joint stress may be the underlying source of pain and interventions often focus on ways to reduce patellofemoral joint stress. Heel lifts have been used as an intervention within Achilles tendon rehabilitation programs and to address leg length discrepancies. The purpose of this study was to examine the effect of running with heel lifts on patellofemoral joint stress, patellofemoral stress impulse, quadriceps force, step length, cadence, and other related kinematic and spatiotemporal variables. A repeated-measures research design. Sixteen healthy female runners completed five running trials in a controlled laboratory setting with and without 11mm heel lifts inserted in a standard running shoe. Kinetic and kinematic data were used in combination with a static optimization technique to estimate individual muscle forces. These data were inserted into a patellofemoral joint model which was used to estimate patellofemoral joint stress and other variables during running. When running with heel lifts, peak patellofemoral joint stress and patellofemoral stress impulse were reduced by a 4.2% (p=0.049) and 9.3% (p=0.002). Initial center of pressure was shifted anteriorly 9.1% when running with heel lifts (p<0.001) despite all runners utilizing a heel strike pattern. Dorsiflexion at initial contact was reduced 28% (p=0.016) when heel lifts were donned. No differences in step length and cadence (p>0.05) were shown between conditions. Heel lift use resulted in decreased patellofemoral joint stress and impulse without associated changes in step length or frequency, or other variables shown to influence patellofemoral joint stress. The center of pressure at initial contact was also more anterior using heel lifts. The use of heel lifts may have therapeutic benefits for runners with patellofemoral pain if the primary goal is to reduce patellofemoral joint stress. 3b.

  14. Novel Methods for Sensing Acoustical Emissions From the Knee for Wearable Joint Health Assessment.

    PubMed

    Teague, Caitlin N; Hersek, Sinan; Toreyin, Hakan; Millard-Stafford, Mindy L; Jones, Michael L; Kogler, Geza F; Sawka, Michael N; Inan, Omer T

    2016-08-01

    We present the framework for wearable joint rehabilitation assessment following musculoskeletal injury. We propose a multimodal sensing (i.e., contact based and airborne measurement of joint acoustic emission) system for at-home monitoring. We used three types of microphones-electret, MEMS, and piezoelectric film microphones-to obtain joint sounds in healthy collegiate athletes during unloaded flexion/extension, and we evaluated the robustness of each microphone's measurements via: 1) signal quality and 2) within-day consistency. First, air microphones acquired higher quality signals than contact microphones (signal-to-noise-and-interference ratio of 11.7 and 12.4 dB for electret and MEMS, respectively, versus 8.4 dB for piezoelectric). Furthermore, air microphones measured similar acoustic signatures on the skin and 5 cm off the skin (∼4.5× smaller amplitude). Second, the main acoustic event during repetitive motions occurred at consistent joint angles (intra-class correlation coefficient ICC(1, 1) = 0.94 and ICC(1, k) = 0.99). Additionally, we found that this angular location was similar between right and left legs, with asymmetry observed in only a few individuals. We recommend using air microphones for wearable joint sound sensing; for practical implementation of contact microphones in a wearable device, interface noise must be reduced. Importantly, we show that airborne signals can be measured consistently and that healthy left and right knees often produce a similar pattern in acoustic emissions. These proposed methods have the potential for enabling knee joint acoustics measurement outside the clinic/lab and permitting long-term monitoring of knee health for patients rehabilitating an acute knee joint injury.

  15. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    PubMed

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  16. Tribological behavior of micro/nano-patterned surfaces in contact with AFM colloidal probe

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoliang; Wang, Xiu; Kong, Wen; Yi, Gewen; Jia, Junhong

    2011-10-01

    In effort to investigate the influence of the micro/nano-patterning or surface texturing on the nanotribological properties of patterned surfaces, the patterned polydimethylsiloxane (PDMS) surfaces with pillars were fabricated by replica molding technique. The surface morphologies of patterned PDMS surfaces with varying pillar sizes and spacing between pillars were characterized by atomic force microscope (AFM) and scanning electron microscope (SEM). The AFM/FFM was used to acquire the friction force images of micro/nano-patterned surfaces using a colloidal probe. A difference in friction force produced a contrast on the friction force images when the colloidal probe slid over different regions of the patterned polymer surfaces. The average friction force of patterned surface was related to the spacing between the pillars and their size. It decreased with the decreasing of spacing between the pillars and the increasing of pillar size. A reduction in friction force was attributed to the reduced area of contact between patterned surface and colloidal probe. Additionally, the average friction force increased with increasing applied load and sliding velocity.

  17. Opening wedge trapezial osteotomy as possible treatment for early trapeziometacarpal osteoarthritis: a biomechanical investigation of radial subluxation, contact area, and contact pressure.

    PubMed

    Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana

    2012-04-01

    Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first

  18. Sound side joint contact forces in below knee amputee gait with an ESAR prosthetic foot.

    PubMed

    Karimi, Mohammad Taghi; Salami, Firooz; Esrafilian, Amir; Heitzmann, Daniel W W; Alimusaj, Merkur; Putz, Cornelia; Wolf, Sebastian I

    2017-10-01

    The incidence of knee and hip joint osteoarthritis in subjects with below knee amputation (BK) appears significantly higher compared to unimpaired subjects, especially in the intact side. However, it is controversial if constant higher loads on the sound side are one of the major factors for an increased osteoarthritis (OA) incidence in subjects with BK, beside other risk factors, e.g. with respect to metabolism. The aim wasto investigate joint contact forces (JCF) calculated by a musculoskeletal model in the intact side and to compare it with those of unimpaired subjects and to further elucidate in how far increased knee JCF are associated with increased frontal plane knee moments. A group of seven subjects with BK amputation and a group of ten unimpaired subjects were recruited for this study. Gait data were measured by 3D motion capture and force plates. OpenSim software was applied to calculate JCF. Maximum joint angles, ground reaction forces, and moments as well as time distance parameters were determined and compared between groups showing no significant differences, with some JCF components of knee and hip even being slightly smaller in subjects with BK compared to the reference group. This positive finding may be due to the selected ESAR foot. However, other beneficial factors may also have influenced this positive result such as the general good health status of the subjects or the thorough and proper fitting and alignment of the prosthesis. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Patterns of Ninety-Day Readmissions Following Total Joint Replacement in a Bundled Payment Initiative.

    PubMed

    Behery, Omar A; Kester, Benjamin S; Williams, Jarrett; Bosco, Joseph A; Slover, James D; Iorio, Richard; Schwarzkopf, Ran

    2017-04-01

    Alternative payment models aim to improve quality and decrease costs associated with total joint replacement. Postoperative readmissions within 90 days are of interest to clinicians and administrators as there is no additional reimbursement beyond the episode bundled payment target price. The aim of this study is to improve the understanding of the patterns of readmission which would better guide perioperative patient management affecting readmissions. We hypothesize that readmissions have different timing, location, and patient health profile patterns based on whether the readmission is related to a medical or surgical diagnosis. A retrospective cohort of 80 readmissions out of 1412 total joint replacement patients reimbursed through a bundled payment plan was analyzed. Patients were grouped by readmission diagnosis (surgical or medical) and the main variables analyzed were time to readmission, location of readmission, and baseline Perioperative Orthopaedic Surgical Home and American Society of Anesthesiologists scores capturing pre-existing state of health. Nonparametric tests and multivariable regressions were used to test associations. Surgical readmissions occurred earlier than medical readmissions (mean 18 vs 33 days, P = .011), and were more likely to occur at the hospital where the surgery was performed (P = .035). Perioperative Orthopaedic Surgical Home and American Society of Anesthesiologists scores did not predict medical vs surgical readmissions (P = .466 and .879) after adjusting for confounding variables. Readmissions appear to follow different patterns depending on whether they are surgical or medical. Surgical readmissions occur earlier than medical readmissions, and more often at the hospital where the surgery was performed. The results of this study suggest that these 2 types of readmissions have different patterns with different implications toward perioperative care and follow-up after total joint replacement. Copyright © 2016 Elsevier Inc

  20. Patterns of direct and indirect contact between cattle and badgers naturally infected with tuberculosis.

    PubMed

    Drewe, J A; O'Connor, H M; Weber, N; McDonald, R A; Delahay, R J

    2013-07-01

    Tuberculosis (TB) due to infection with Mycobacterium bovis is transmitted between cattle and badgers (Meles meles) in the UK and Ireland but it is unclear where or when transmission occurs. We investigated direct and indirect interactions between badgers and cattle using automated proximity loggers on animals and at badger latrines located on pasture, in an area of south-west England with a high-density badger population. Direct contacts (interactions within 1.4 m) between badgers and cattle at pasture were very rare (four out of >500000 recorded animal-to-animal contacts) despite ample opportunity for interactions to occur. Indirect interactions (visits to badger latrines by badgers and cattle) were two orders of magnitude more frequent than direct contacts: 400 visits by badgers and 1700 visits by cattle were recorded. This suggests that indirect contacts might be more important than direct contacts in terms of disease transmission at pasture. The TB infection status of individual badgers (ascribed with 93% accuracy using three diagnostic tests) did not affect the frequency or duration of their visits to latrines located on pasture grazed by cattle. Nevertheless, there was wide variation in contact behaviour between individuals, which highlights the importance of understanding heterogeneity in contact patterns when developing strategies to control disease spread in wildlife and livestock.

  1. Neuromuscular-skeletal origins of predominant patterns of coordination in rhythmic two-joint arm movement.

    PubMed

    de Rugy, Aymar; Riek, Stephan; Carson, Richard G

    2006-01-01

    The authors tested for predominant patterns of coordination in the combination of rhythmic flexion-extension (FE) and supination- (SP) at the elbow-joint complex. Participants (N=10) spontaneously established in-phase (supination synchronized with flexion) and antiphase (pronation synchronized with flexion) patterns. In addition, the authors used a motorized robot arm to generate involuntary SP movements with different phase relations with respect to voluntary FE. The involuntarily induced in-phase pattern was accentuated and was more consistent than other patterns. The result provides evidence that the predominance of the in-phase pattern originates in the influence of neuromuscular-skeletal constraints rather than in a preference dictated by perceptual-cognitive factors implicated in voluntary control. Neuromuscular-skeletal constraints involved in the predominance of the in-phase and the antiphase patterns are discussed.

  2. Immediate effects of modified landing pattern on a probabilistic tibial stress fracture model in runners.

    PubMed

    Chen, T L; An, W W; Chan, Z Y S; Au, I P H; Zhang, Z H; Cheung, R T H

    2016-03-01

    Tibial stress fracture is a common injury in runners. This condition has been associated with increased impact loading. Since vertical loading rates are related to the landing pattern, many heelstrike runners attempt to modify their footfalls for a lower risk of tibial stress fracture. Such effect of modified landing pattern remains unknown. This study examined the immediate effects of landing pattern modification on the probability of tibial stress fracture. Fourteen experienced heelstrike runners ran on an instrumented treadmill and they were given augmented feedback for landing pattern switch. We measured their running kinematics and kinetics during different landing patterns. Ankle joint contact force and peak tibial strains were estimated using computational models. We used an established mathematical model to determine the effect of landing pattern on stress fracture probability. Heelstrike runners experienced greater impact loading immediately after landing pattern switch (P<0.004). There was an increase in the longitudinal ankle joint contact force when they landed with forefoot (P=0.003). However, there was no significant difference in both peak tibial strains and the risk of tibial stress fracture in runners with different landing patterns (P>0.986). Immediate transitioning of the landing pattern in heelstrike runners may not offer timely protection against tibial stress fracture, despite a reduction of impact loading. Long-term effects of landing pattern switch remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Experimental and numerical study of Bondura® 6.6 PIN joints

    NASA Astrophysics Data System (ADS)

    Berkani, I.; Karlsen, Ø.; Lemu, H. G.

    2017-12-01

    Pin joints are widely used in heavy-duty machinery such as aircrafts, cranes and offshore drilling equipment to transfer multi-dimensional shear forces. Their strength and service life depend on the clamping force in the contact region that is provided by interference fits. Though the interference fits provide full contact at the pin-hole interface under pretension loads, the contact interface reduces when the pin is subjected to an external load and hence a smaller contact surface leads to dramatic increase of the contact stress. The PIN joint of Bondura® Technology, investigated in this study, is an innovative solution intended to reduce the slack at the contact surface of the pin joint of heavy-duty machinery by using tapered sleeves on each end of the PIN. The study is aimed to better understand the contact pressure build-up and stress distribution in the supporting contact surface under pre-loading of the joint and the influence of temperature difference between part assembly and operation conditions. Numerical simulation using finite element method and diverse experimental tests were conducted. The numerical simulation and the test results, particularly the tests conducted with lubricated joints, show good conformance.

  4. Lower extremity joint loads in habitual rearfoot and mid/forefoot strike runners with normal and shortened stride lengths.

    PubMed

    Boyer, Elizabeth R; Derrick, Timothy R

    2018-03-01

    Our purpose was to compare joint loads between habitual rearfoot (hRF) and habitual mid/forefoot strikers (hFF), rearfoot (RFS) and mid/forefoot strike (FFS) patterns, and shorter stride lengths (SLs). Thirty-eight hRF and hFF ran at their normal SL, 5% and 10% shorter, as well as with the opposite foot strike. Three-dimensional ankle, knee, patellofemoral (PF) and hip contact forces were calculated. Nearly all contact forces decreased with a shorter SL (1.2-14.9% relative to preferred SL). In general, hRF had higher PF (hRF-RFS: 10.8 ± 1.4, hFF-FFS: 9.9 ± 2.0 BWs) and hip loads (axial hRF-RFS: -9.9 ± 0.9, hFF-FFS: -9.6 ± 1.0 BWs) than hFF. Many loads were similar between foot strike styles for the two groups, including axial and lateral hip, PF, posterior knee and shear ankle contact forces. Lateral knee and posterior hip contact forces were greater for RFS, and axial ankle and knee contact forces were greater for FFS. The tibia may be under greater loading with a FFS because of these greater axial forces. Summarising, a particular foot strike style does not universally decrease joint contact forces. However, shortening one's SL 10% decreased nearly all lower extremity contact forces, so it may hold potential to decrease overuse injuries associated with excessive joint loads.

  5. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in

  6. Bio-inspired control of joint torque and knee stiffness in a robotic lower limb exoskeleton using a central pattern generator.

    PubMed

    Schrade, Stefan O; Nager, Yannik; Wu, Amy R; Gassert, Roger; Ijspeert, Auke

    2017-07-01

    Robotic lower limb exoskeletons are becoming increasingly popular in therapy and recreational use. However, most exoskeletons are still rather limited in their locomotion speed and the activities of daily live they can perform. Furthermore, they typically do not allow for a dynamic adaptation to the environment, as they are often controlled with predefined reference trajectories. Inspired by human leg stiffness modulation during walking, variable stiffness actuators increase flexibility without the need for more complex controllers. Actuation with adaptable stiffness is inspired by the human leg stiffness modulation during walking. However, this actuation principle also introduces the stiffness setpoint as an additional degree of freedom that needs to be coordinated with the joint trajectories. As a potential solution to this issue a bio-inspired controller based on a central pattern generator (CPG) is presented in this work. It generates coordinated joint torques and knee stiffness modulations to produce flexible and dynamic gait patterns for an exoskeleton with variable knee stiffness actuation. The CPG controller is evaluated and optimized in simulation using a model of the exoskeleton. The CPG controller produced stable and smooth gait for walking speeds from 0.4 m/s up to 1.57 m/s with a torso stabilizing force that simulated the use of crutches, which are commonly needed by exoskeleton users. Through the CPG, the knee stiffness intrinsically adapted to the frequency and phase of the gait, when the speed was changed. Additionally, it adjusted to changes in the environment in the form of uneven terrain by reacting to ground contact forces. This could allow future exoskeletons to be more adaptive to various environments, thus making ambulation more robust.

  7. Utilization and growth patterns of sacroiliac joint injections from 2000 to 2011 in the medicare population.

    PubMed

    Manchikanti, Laxmaiah; Hansen, Hans; Pampati, Vidyasagar; Falco, Frank J E

    2013-01-01

      The high prevalence of persistent low back pain and growing number of diagnostic and therapeutic modalities employed to manage chronic low back pain and the subsequent impact on society and the economy continue to hold sway over health care policy. Among the multiple causes responsible for chronic low back pain, the contributions of the sacroiliac joint have been a subject of debate albeit a paucity of research. At present, there are no definitive conservative, interventional or surgical management options for managing sacroiliac joint pain. It has been shown that the increases were highest for facet joint interventions and sacroiliac joint blocks with an increase of 310% per 100,000 Medicare beneficiaries from 2000 to 2011. There has not been a systematic assessment of the utilization and growth patterns of sacroiliac joint injections. Analysis of the growth patterns of sacroiliac joint injections in Medicare beneficiaries from 2000 to 2011. To evaluate the utilization and growth patterns of sacroiliac joint injections. This assessment was performed utilizing Centers for Medicare and Medicaid Services (CMS) Physician/Supplier Procedure Summary (PSPS) Master data from 2000 to 2011. The findings of this assessment in Medicare beneficiaries from 2000 to 2011 showed a 331% increase per 100,000 Medicare beneficiaries with an annual increase of 14.2%, compared to an increase in the Medicare population of 23% or annual increase of 1.9%. The number of procedures increased from 49,554 in 2000 to 252,654 in 2011, or a rate of 125 to 539 per 100,000 Medicare beneficiaries. Among the various specialists performing sacroiliac joint injections, physicians specializing in physical medicine and rehabilitation have shown the most increase, followed by neurology with 1,568% and 698%, even though many physicians from both specialties have been enrolling in interventional pain management and pain management. Even though the numbers were small for nonphysician providers including

  8. The Joint Chiefs of Staff Video Collections

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Home : Media : Videos Featured Videos Gen

  9. Patterns of Contact with Hospital for Children with an Autism Spectrum Disorder: A Danish Register-Based Study

    ERIC Educational Resources Information Center

    Atladottir, Hjordis Osk; Schendel, Diana E.; Lauritsen, Marlene B.; Henriksen, Tine Brink; Parner, Erik T.

    2012-01-01

    The aim of this study was to study patterns of contact with hospital for children with autism spectrum disorder (ASD) using Danish population based register data. We included all children born in Denmark from 1994 through 2002. We found that children diagnosed with ASD had an increased rate of contact with hospital, almost regardless of the cause…

  10. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  11. Modeling contact angle hysteresis of a liquid droplet sitting on a cosine wave-like pattern surface.

    PubMed

    Promraksa, Arwut; Chen, Li-Jen

    2012-10-15

    A liquid droplet sitting on a hydrophobic surface with a cosine wave-like square-array pattern in the Wenzel state is simulated by using the Surface Evolver to determine the contact angle. For a fixed drop volume, multiple metastable states are obtained at two different surface roughnesses. Unusual and non-circular shape of the three-phase contact line of a liquid droplet sitting on the model surface is observed due to corrugation and distortion of the contact line by structure of the roughness. The contact angle varies along the contact line for each metastable state. The maximum and minimum contact angles among the multiple metastable states at a fixed viewing angle correspond to the advancing and the receding contact angles, respectively. It is interesting to observe that the advancing/receding contact angles (and contact angle hysteresis) are a function of viewing angle. In addition, the receding (or advancing) contact angles at different viewing angles are determined at different metastable states. The contact angle of minimum energy among the multiple metastable states is defined as the most stable (equilibrium) contact angle. The Wenzel model is not able to describe the contact angle along the three-phase contact line. The contact angle hysteresis at different drop volumes is determined. The number of the metastable states increases with increasing drop volume. Drop volume effect on the contact angles is also discussed. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  12. Joint Chiefs of Staff > Directorates > J3 | Operations

    Science.gov Websites

    Joint Staff Structure Joint Staff Inspector General Origin of Joint Concepts U.S. Code | Joint Chiefs of J8 | Force Structure, Resources & Assessment Contact J3 Operations Home : Directorates : J3

  13. Discrete element analysis is a valid method for computing joint contact stress in the hip before and after acetabular fracture.

    PubMed

    Townsend, Kevin C; Thomas-Aitken, Holly D; Rudert, M James; Kern, Andrew M; Willey, Michael C; Anderson, Donald D; Goetz, Jessica E

    2018-01-23

    Evaluation of abnormalities in joint contact stress that develop after inaccurate reduction of an acetabular fracture may provide a potential means for predicting the risk of developing post-traumatic osteoarthritis. Discrete element analysis (DEA) is a computational technique for calculating intra-articular contact stress distributions in a fraction of the time required to obtain the same information using the more commonly employed finite element analysis technique. The goal of this work was to validate the accuracy of DEA-computed contact stress against physical measurements of contact stress made in cadaveric hips using Tekscan sensors. Four static loading tests in a variety of poses from heel-strike to toe-off were performed in two different cadaveric hip specimens with the acetabulum intact and again with an intentionally malreduced posterior wall acetabular fracture. DEA-computed contact stress was compared on a point-by-point basis to stress measured from the physical experiments. There was good agreement between computed and measured contact stress over the entire contact area (correlation coefficients ranged from 0.88 to 0.99). DEA-computed peak contact stress was within an average of 0.5 MPa (range 0.2-0.8 MPa) of the Tekscan peak stress for intact hips, and within an average of 0.6 MPa (range 0-1.6 MPa) for fractured cases. DEA-computed contact areas were within an average of 33% of the Tekscan-measured areas (range: 1.4-60%). These results indicate that the DEA methodology is a valid method for accurately estimating contact stress in both intact and fractured hips. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Tactile Robotic Topographical Mapping Without Force or Contact Sensors

    NASA Technical Reports Server (NTRS)

    Burke, Kevin; Melko, Joseph; Krajewski, Joel; Cady, Ian

    2008-01-01

    A method of topographical mapping of a local solid surface within the range of motion of a robot arm is based on detection of contact between the surface and the end effector (the fixture or tool at the tip of the robot arm). The method was conceived to enable mapping of local terrain by an exploratory robot on a remote planet, without need to incorporate delicate contact switches, force sensors, a vision system, or other additional, costly hardware. The method could also be used on Earth for determining the size and shape of an unknown surface in the vicinity of a robot, perhaps in an unanticipated situation in which other means of mapping (e.g., stereoscopic imaging or laser scanning with triangulation) are not available. The method uses control software modified to utilize the inherent capability of the robotic control system to measure the joint positions, the rates of change of the joint positions, and the electrical current demanded by the robotic arm joint actuators. The system utilizes these coordinate data and the known robot-arm kinematics to compute the position and velocity of the end effector, move the end effector along a specified trajectory, place the end effector at a specified location, and measure the electrical currents in the joint actuators. Since the joint actuator current is approximately proportional to the actuator forces and torques, a sudden rise in joint current, combined with a slowing of the joint, is a possible indication of actuator stall and surface contact. Hence, even though the robotic arm is not equipped with contact sensors, it is possible to sense contact (albeit with reduced sensitivity) as the end effector becomes stalled against a surface that one seeks to measure.

  15. Using Contact Patterns to Inform HIV Interventions in Persons Who Inject Drugs in Northern Vietnam.

    PubMed

    Smith, M Kumi; Graham, Matthew; Latkin, Carl A; Go, Vivian L

    2018-05-01

    Population mixing patterns can greatly inform allocation of HIV prevention interventions such as treatment as prevention or preexposure prophylaxis. Characterizing contact patterns among subgroups can help identify the specific combinations of contact expected to result in the greatest number of new infections. Baseline data from an intervention to reduce HIV-related risk behaviors in male persons who inject drugs (PWID) in the Northern Vietnamese province of Thai Nguyen were used for the analysis. Egocentric network data were provided by PWID who reported any drug-injection equipment sharing in the previous 3 months. Age-dependent mixing was assessed to explore its epidemiological implications on risk of HIV transmission risk (among those HIV-infected) and HIV acquisition risk (among those not infected) in PWID. A total of 1139 PWID collectively reported 2070 equipment-sharing partnerships in the previous 3 months. Mixing by age identified the 30-34 and 35-39 years age groups as the groups from whom the largest number of new infections was transmitted, making them primary targets for treatment as prevention. Among the uninfected, 25-29, 30-35, and 35-39 years age groups had the highest HIV acquisition rate, making them the primary targets for preexposure prophylaxis. Collection and analysis of contact patterns in PWID is feasible and can greatly inform infectious disease dynamics and targeting of appropriate interventions. Results presented also provide much needed empirical data on mixing to improve mathematical models of disease transmission in this population.

  16. Infrared target recognition based on improved joint local ternary pattern

    NASA Astrophysics Data System (ADS)

    Sun, Junding; Wu, Xiaosheng

    2016-05-01

    This paper presents a simple, efficient, yet robust approach, named joint orthogonal combination of local ternary pattern, for automatic forward-looking infrared target recognition. It gives more advantages to describe the macroscopic textures and microscopic textures by fusing variety of scales than the traditional LBP-based methods. In addition, it can effectively reduce the feature dimensionality. Further, the rotation invariant and uniform scheme, the robust LTP, and soft concave-convex partition are introduced to enhance its discriminative power. Experimental results demonstrate that the proposed method can achieve competitive results compared with the state-of-the-art methods.

  17. About the Joint Chiefs of Staff

    Science.gov Websites

    JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Home : About About the Joint Chiefs of Staff Download the CJCS Historic Guide The Joint Chiefs of Staff consist of the Chairman

  18. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  19. Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

    PubMed

    Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J

    2013-06-01

    Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.

  20. Abnormal Patterns of Tongue-Palate Contact in the Speech of Individuals with Cleft Palate

    ERIC Educational Resources Information Center

    Gibbon, Fiona

    2004-01-01

    Individuals with cleft palate, even those with adequate velopharyngeal function, are at high risk for disordered lingual articulation. This article attempts to summarize current knowledge of abnormal tongue-palate contact patterns derived from electropalatographic (EPG) data in speakers with cleft palate. These data, which have been reported in 23…

  1. Patterns of Contact and Cooperation between Juvenile Probation Officers and Parents of Youthful Offenders

    ERIC Educational Resources Information Center

    Schwalbe, Craig S.; Maschi, Tina

    2010-01-01

    This study documents patterns of contact between juvenile probation officers and parents and examines factors associated with officer judgments about parental cooperation. Data for the study was derived from a Web-based survey of probation officers (N = 308) who reported their use of probation strategies with specific youths identified from their…

  2. A Parametric Approach to Numerical Modeling of TKR Contact Forces

    PubMed Central

    Lundberg, Hannah J.; Foucher, Kharma C.; Wimmer, Markus A.

    2009-01-01

    In vivo knee contact forces are difficult to determine using numerical methods because there are more unknown forces than equilibrium equations available. We developed parametric methods for computing contact forces across the knee joint during the stance phase of level walking. Three-dimensional contact forces were calculated at two points of contact between the tibia and the femur, one on the lateral aspect of the tibial plateau, and one on the medial side. Muscle activations were parametrically varied over their physiologic range resulting in a solution space of contact forces. The obtained solution space was reasonably small and the resulting force pattern compared well to a previous model from the literature for kinematics and external kinetics from the same patient. Peak forces of the parametric model and the previous model were similar for the first half of the stance phase, but differed for the second half. The previous model did not take into account the transverse external moment about the knee and could not calculate muscle activation levels. Ultimately, the parametric model will result in more accurate contact force inputs for total knee simulators, as current inputs are not generally based on kinematics and kinetics inputs from TKR patients. PMID:19155015

  3. EFFECT OF HEEL LIFTS ON PATELLOFEMORAL JOINT STRESS DURING RUNNING

    PubMed Central

    Mestelle, Zachary; Kernozek, Thomas; Adkins, Kelly S.; Miller, Jessica; Gheidi, Naghmeh

    2017-01-01

    Background Patellofemoral pain is a debilitating injury for many recreational runners. Excessive patellofemoral joint stress may be the underlying source of pain and interventions often focus on ways to reduce patellofemoral joint stress. Purpose Heel lifts have been used as an intervention within Achilles tendon rehabilitation programs and to address leg length discrepancies. The purpose of this study was to examine the effect of running with heel lifts on patellofemoral joint stress, patellofemoral stress impulse, quadriceps force, step length, cadence, and other related kinematic and spatiotemporal variables. Study Design A repeated-measures research design Methods Sixteen healthy female runners completed five running trials in a controlled laboratory setting with and without 11mm heel lifts inserted in a standard running shoe. Kinetic and kinematic data were used in combination with a static optimization technique to estimate individual muscle forces. These data were inserted into a patellofemoral joint model which was used to estimate patellofemoral joint stress and other variables during running. Results When running with heel lifts, peak patellofemoral joint stress and patellofemoral stress impulse were reduced by a 4.2% (p=0.049) and 9.3% (p=0.002). Initial center of pressure was shifted anteriorly 9.1% when running with heel lifts (p<0.001) despite all runners utilizing a heel strike pattern. Dorsiflexion at initial contact was reduced 28% (p=0.016) when heel lifts were donned. No differences in step length and cadence (p>0.05) were shown between conditions. Conclusions Heel lift use resulted in decreased patellofemoral joint stress and impulse without associated changes in step length or frequency, or other variables shown to influence patellofemoral joint stress. The center of pressure at initial contact was also more anterior using heel lifts. The use of heel lifts may have therapeutic benefits for runners with patellofemoral pain if the primary goal is

  4. Weightlifting performance is related to kinematic and kinetic patterns of the hip and knee joints.

    PubMed

    Kipp, Kristof; Redden, Josh; Sabick, Michelle B; Harris, Chad

    2012-07-01

    The purpose of this study was to investigate the correlations between biomechanical outcome measures and weightlifting performance. Joint kinematics and kinetics of the hip, knee, and ankle were calculated while 10 subjects performed a clean at 85% of 1 repetition maximum (1RM). Kinematic and kinetic time-series patterns were extracted with principal components analysis. Discrete scores for each time-series pattern were calculated and used to determine how each pattern was related to body mass-normalized 1RM. Two hip kinematic and 2 knee kinetic patterns were significantly correlated with relative 1RM. The kinematic patterns captured hip and trunk motions during the first pull and hip joint motion during the movement transition between the first and second pulls. The first kinetic pattern captured a peak in the knee extension moment during the second pull. The second kinetic pattern captured a spatiotemporal shift in the timing and amplitude of the peak knee extension moment. The kinematic results suggest that greater lift mass was associated with steady trunk position during the first pull and less hip extension motion during the second-knee bend transition. Further, the kinetic results suggest that greater lift mass was associated with a smaller knee extensor moments during the first pull, but greater knee extension moments during the second pull, and an earlier temporal transition between knee flexion-extension moments at the beginning of the second pull. Collectively, these results highlight the importance of controlled trunk and hip motions during the first pull and rapid employment of the knee extensor muscles during the second pull in relation to weightlifting performance.

  5. Effect of distal ulnar collateral ligament tear pattern on contact forces and valgus stability in the posteromedial compartment of the elbow.

    PubMed

    Hassan, Sheref E; Parks, Brent G; Douoguih, Wiemi A; Osbahr, Daryl C

    2015-02-01

    It is not known whether the pattern of ulnar collateral ligament (UCL) tear affects elbow biomechanics. There will be a significant change in elbow biomechanics with 50% proximal but not 50% distal simulated rupture of the UCL. Controlled laboratory study. Pressure sensors in the posteromedial elbow joint of 25 male cadaveric elbows (average age, 54.9 years; range, 26-66 years) were used to measure contact area, pressure, and valgus torque at 90° and 30° of elbow flexion. Thirteen specimens were tested with the UCL intact, then with proximal-to-distal detachment of 50%, and then with proximal-to-distal detachment of 100% of the anterior band of the UCL from the ulnar attachment. This method was repeated in the remaining 12 specimens in a distal-to-proximal direction. With 50% proximal-to-distal detachment, contact area decreased significantly versus intact at 90° (91.3 ± 23.6 vs 112.2 ± 26.0 mm(2); P < .001) and 30° (69.3 ± 14.8 vs 83.1 ± 21.6 mm(2); P < .001) of elbow flexion; the center of pressure (COP) moved significantly proximally versus intact at 90° (3.8 ± 2.5 vs 5.4 ± 2.3 mm; P < .001) and 30° (5.9 ± 2.8 vs 7.4±1.9 mm; P < .001). With 50% distal-to-proximal UCL detachment versus intact, no significant change was observed in contact area, movement of the COP, or valgus laxity at either flexion position. With 100% proximal-to-distal and distal-to-proximal detachment, significant change in contact area, movement of the COP, and valgus laxity versus intact was found at 90° and 30° of elbow flexion (P < .05). No significant difference in contact pressure was observed in any test conditions. Significant change in contact area and proximal movement of the COP with 50% proximal UCL detachment and the lack of significant change with 50% distal UCL detachment suggest that the proximal half of the UCL ulnar footprint has a primary role in maintaining posteromedial elbow biomechanics. The findings suggest that surgical reconstruction should aim to

  6. Proposal on Calculation of Ventilation Threshold Using Non-contact Respiration Measurement with Pattern Light Projection

    NASA Astrophysics Data System (ADS)

    Aoki, Hirooki; Ichimura, Shiro; Fujiwara, Toyoki; Kiyooka, Satoru; Koshiji, Kohji; Tsuzuki, Keishi; Nakamura, Hidetoshi; Fujimoto, Hideo

    We proposed a calculation method of the ventilation threshold using the non-contact respiration measurement with dot-matrix pattern light projection under pedaling exercise. The validity and effectiveness of our proposed method is examined by simultaneous measurement with the expiration gas analyzer. The experimental result showed that the correlation existed between the quasi ventilation thresholds calculated by our proposed method and the ventilation thresholds calculated by the expiration gas analyzer. This result indicates the possibility of the non-contact measurement of the ventilation threshold by the proposed method.

  7. A Common Force-Sharing Pattern in Joint Action That Consists of Four People.

    PubMed

    Masumoto, Junya; Inui, Nobuyuki

    2017-12-20

    The authors examined the force-sharing patterns in a joint action performed by a group of two, three, or four people compared with a solo action. In the joint actions, 28 participants produced periodic isometric forces such that the sum of forces they produced cycled between 5% and 10% maximum voluntary contraction with the right hand at 1 Hz. In both the three- and four-person tasks, the correlation between forces produced by two of the three or four participants was negative, and the remaining one or two participants produced intermediate forces. The errors of force and interval and force variabilities were smaller in four- and three-people groups than individuals. Four- and three-people groups thus performed better than individuals.

  8. Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow.

    PubMed

    Bellato, Enrico; Fitzsimmons, James S; Kim, Youngbok; Bachman, Daniel R; Berglund, Lawrence J; Hooke, Alexander W; O'Driscoll, Shawn W

    2018-03-21

    Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm to 150 ± 58 mm (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in

  9. A general design strategy for block copolymer directed self-assembly patterning of integrated circuits contact holes using an alphabet approach.

    PubMed

    Yi, He; Bao, Xin-Yu; Tiberio, Richard; Wong, H-S Philip

    2015-02-11

    Directed self-assembly (DSA) is a promising lithography candidate for technology nodes beyond 14 nm. Researchers have shown contact hole patterning for random logic circuits using DSA with small physical templates. This paper introduces an alphabet approach that uses a minimal set of small physical templates to pattern all contacts configurations on integrated circuits. We illustrate, through experiments, a general and scalable template design strategy that links the DSA material properties to the technology node requirements.

  10. Structural optimization of an alternate design for the Space Shuttle solid rocket booster field joint

    NASA Technical Reports Server (NTRS)

    Barthelemy, Jean-Francois M.; Rogers, James L., Jr.; Chang, Kwan J.

    1987-01-01

    A structural optimization procedure is used to determine the shape of an alternate design for the Shuttle's solid rocket booster field joint. In contrast to the tang and clevis design of the existing joint, this alternate design consists of two flanges bolted together. Configurations with 150 studs of 1 1/8 in diameter and 135 studs of 1 3/16 in diameter are considered. Using a nonlinear programming procedure, the joint weight is minimized under constraints on either von Mises or maximum normal stresses, joint opening and geometry. The procedure solves the design problem by replacing it by a sequence of approximate (convex) subproblems; the pattern of contact between the joint halves is determined every few cycles by a nonlinear displacement analysis. The minimum weight design has 135 studs of 1 3/16 in diameter and is designed under constraints on normal stresses. It weighs 1144 lb per joint more than the current tang and clevis design.

  11. The initial effects of knee joint mobilization on osteoarthritic hyperalgesia.

    PubMed

    Moss, Penny; Sluka, Kathleen; Wright, Anthony

    2007-05-01

    Physiotherapists often employ lower limb joint mobilization to reduce pain and increase function. However, there is little experimental data confirming its efficacy. The purpose of this study was to investigate the initial effects of accessory knee joint mobilization on measures of pain and function in individuals with knee osteoarthritis. The study employed a double-blind, controlled, within-subjects repeated-measures design. Thirty-eight subjects with mild to moderate knee pain participated. The effects of a 9-min, non-noxious, AP mobilization of the tibio-femoral joint were compared with manual contact and no-contact interventions. Pressure pain threshold (PPT) and 3-m 'up and go' time were measured immediately before and after each intervention. Results demonstrated a significantly greater mean (95% CI) percentage increase in PPT following knee joint mobilization (27.3% (20.9-33.7)) than after manual contact (6.4% (0.4-12.4)) or no-contact (-9.6% (-20.7 to 1.6)) interventions. Knee joint mobilization also increased PPT at a distal, non-painful site and reduced 'up and go' time significantly more (-5% (-9.3 to 0.8)) than manual contact (-0.4% (-4.2 to 3.5)) or no-contact control (+7.9% (2.6-13.2)) interventions. This study therefore provides new experimental evidence that accessory mobilization of an osteoarthritic knee joint immediately produces both local and widespread hypoalgesic effects. It may therefore be an effective means of reducing pain in this population.

  12. Social contact patterns of infants in deciding vaccination strategy: a prospective, cross-sectional, single-centre study.

    PubMed

    Oguz, M M; Camurdan, A D; Aksakal, F N; Akcaboy, M; Altinel Acoglu, E

    2018-05-09

    Social contact between individuals is believed to be a fundamental cause in the transmission of many respiratory tract infections. Because they have not yet been fully vaccinated, infants are at high risk for contracting whooping cough, influenza and their serious complications. Therefore, determining infant social contact patterns is an important step in protecting them from respiratory tract infection. This study included 1200 healthy infants (<12 months of age). Social contact diaries were used to estimate the frequency and nature of the infants' social contacts. This survey also gathered information regarding the infants' respiratory symptoms and their frequency of attendance at crowded places over a period of 1 week. The diary return rate was 83.8% (N = 1006), and there was a total of 4706 contacts reported for these infants. The median daily contact number per capita was 4 (range 1-18). The median number of contacts with adolescents was 0 (range 0-7). Of the infants, 50.3% had contact with non-household individuals. The mothers had the longest contacts with their babies. Contacts with school children, frequency of attendance at crowded places and age were determined to be significant effective factors for reporting respiratory symptoms. Results suggest that school-age siblings and the mothers should be primarily vaccinated, and parents should keep their babies away from crowded places for protecting their infants.

  13. Contact-Induced Language Alternation in Tanzanian Ngoni--An Empirical Study of Frequency and Patterns

    ERIC Educational Resources Information Center

    Rosendal, Tove; Mapunda, Gastor

    2017-01-01

    The codeswitching pattern is different in rural Tanzania compared to urban agglomerations around the world. Even in very rural areas people in Tanzania are bilingual in Swahili, the national and local lingua franca, and their own first language. The result of this language contact is understudied and has only recently been focused on. This paper…

  14. Patellofemoral joint contact forces during activities with high knee flexion.

    PubMed

    Trepczynski, Adam; Kutzner, Ines; Kornaropoulos, Evgenios; Taylor, William R; Duda, Georg N; Bergmann, Georg; Heller, Markus O

    2012-03-01

    The patellofemoral (PF) joint plays an essential role in knee function, but little is known about the in vivo loading conditions at the joint. We hypothesized that the forces at the PF joint exceed the tibiofemoral (TF) forces during activities with high knee flexion. Motion analysis was performed in two patients with telemetric knee implants during walking, stair climbing, sit-to-stand, and squat. TF and PF forces were calculated using a musculoskeletal model, which was validated against the simultaneously measured in vivo TF forces, with mean errors of 10% and 21% for the two subjects. The in vivo peak TF forces of 2.9-3.4 bodyweight (BW) varied little across activities, while the peak PF forces showed significant variability, ranging from less than 1 BW during walking to more than 3 BW during high flexion activities, exceeding the TF forces. Together with previous in vivo measurements at the hip and knee, the PF forces determined here provide evidence that peak forces across these joints reach values of around 3 BW during high flexion activities, also suggesting that the in vivo loading conditions at the knee can only be fully understood if the forces at the TF and the PF joints are considered together. Copyright © 2011 Orthopaedic Research Society.

  15. The Effect of Eye Contact Is Contingent on Visual Awareness

    PubMed Central

    Xu, Shan; Zhang, Shen; Geng, Haiyan

    2018-01-01

    The present study explored how eye contact at different levels of visual awareness influences gaze-induced joint attention. We adopted a spatial-cueing paradigm, in which an averted gaze was used as an uninformative central cue for a joint-attention task. Prior to the onset of the averted-gaze cue, either supraliminal (Experiment 1) or subliminal (Experiment 2) eye contact was presented. The results revealed a larger subsequent gaze-cueing effect following supraliminal eye contact compared to a no-contact condition. In contrast, the gaze-cueing effect was smaller in the subliminal eye-contact condition than in the no-contact condition. These findings suggest that the facilitation effect of eye contact on coordinating social attention depends on visual awareness. Furthermore, subliminal eye contact might have an impact on subsequent social attention processes that differ from supraliminal eye contact. This study highlights the need to further investigate the role of eye contact in implicit social cognition. PMID:29467703

  16. Image based weighted center of proximity versus directly measured knee contact location during simulated gait

    PubMed Central

    Wang, Hongsheng; Chen, Tony; Koff, Matthew F.; Hutchinson, Ian D.; Gilbert, Susannah; Choi, Dan; Warren, Russell F.; Rodeo, Scott A.; Maher, Suzanne A.

    2014-01-01

    To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities – using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (P < 0.01, 95% confidence interval of Person’s coefficient r > 0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (P > 0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction. PMID:24837219

  17. Influence of partial meniscectomy on attachment forces, superficial strain and contact mechanics in porcine knee joints.

    PubMed

    Freutel, Maren; Seitz, Andreas M; Ignatius, Anita; Dürselen, Lutz

    2015-01-01

    Numerous studies investigated the reasons for premature osteoarthritis due to partial meniscectomy (PM). However, the influence of meniscectomy on attachment forces and superficial strain of the tibial meniscus is unclear. It is hypothesised that these parameters depend on the degree of PM. Six porcine medial menisci were placed in a custom made apparatus, and each meniscal attachment was connected to a force sensor. After printing markers onto the tibial meniscal surfaces, the menisci were positioned on a glass plate enabling optical superficial strain measurement. Additionally, contact area and pressure were investigated. Each meniscus was axially loaded up to 650 N using its respective femoral condyle. Testing was conducted intact and after 50 and 75% PM of the posterior horn and extending 75% PM to the anterior horn. With increasing meniscectomy, the attachment forces decreased anteriorly by up to 17% (n.s.) and posteriorly by up to 55% (p = 0.003). The circumferential strain in the peripheral meniscal zones was not affected by the meniscectomy, while in some meniscal zones the radial strain changed from compression to tension. Contact area decreased by up to 23% (p = 0.01), resulting in an increase in 40% (p = 0.02) for the maximum contact pressure. Partial meniscectomy significantly alters the loading situation of the meniscus and its attachments. Specifically, the attachment forces decreased with increasing amount of meniscal tissue loss, which reflects the impaired ability of the meniscus to transform axial joint load into meniscal hoop stress.

  18. The development of contact force construction in the dynamic-contact task of cycling [corrected].

    PubMed

    Brown, Nicholas A T; Jensen, Jody L

    2003-01-01

    Purposeful movement requires that an individual produce appropriate joint torques to accelerate segments, and when environmental contact is involved, to develop task-appropriate contact forces. Developmental research has been confined largely to the mastery of unconstrained movement skills (pointing, kicking). The purpose of this study was to study the developmental progression that characterizes the interaction of muscular and non-muscular forces in tasks constrained by contact with the environment. Seven younger children (YC, 6-8 years), 7 older children (OC, 9-11 years) and 7 adults (AD) pedaled an ergometer (80 rpm) at an anthropometrically scaled cycling power. Resultant forces measured at the pedal's surface were decomposed into muscle, inertia and gravity components. Muscle pedal forces were further examined in terms of the underlying lower extremity joint torques and kinematic weights that constitute the muscular component of the pedal force. Data showed children applied muscle forces to the pedal in a significantly different manner compared to adults, and that this was due to the children's lower segmental mass and inertia. The children adjusted the contribution of the proximal joint muscle torques to compensate for reduced contributions to the resultant pedal force by gravitational and inertial components. These data show that smaller segmental mass and inertia limit younger children's ability to construct the dynamic-contact task of cycling in an adult-like form. On the basis of these results, however, the children's response was not "immature". Rather, the results show a task-appropriate adaptation to lower segmental mass and inertia. Copyright 2002 Elsevier Science Ltd.

  19. Modeling workplace contact networks: The effects of organizational structure, architecture, and reporting errors on epidemic predictions.

    PubMed

    Potter, Gail E; Smieszek, Timo; Sailer, Kerstin

    2015-09-01

    Face-to-face social contacts are potentially important transmission routes for acute respiratory infections, and understanding the contact network can improve our ability to predict, contain, and control epidemics. Although workplaces are important settings for infectious disease transmission, few studies have collected workplace contact data and estimated workplace contact networks. We use contact diaries, architectural distance measures, and institutional structures to estimate social contact networks within a Swiss research institute. Some contact reports were inconsistent, indicating reporting errors. We adjust for this with a latent variable model, jointly estimating the true (unobserved) network of contacts and duration-specific reporting probabilities. We find that contact probability decreases with distance, and that research group membership, role, and shared projects are strongly predictive of contact patterns. Estimated reporting probabilities were low only for 0-5 min contacts. Adjusting for reporting error changed the estimate of the duration distribution, but did not change the estimates of covariate effects and had little effect on epidemic predictions. Our epidemic simulation study indicates that inclusion of network structure based on architectural and organizational structure data can improve the accuracy of epidemic forecasting models.

  20. Modeling workplace contact networks: The effects of organizational structure, architecture, and reporting errors on epidemic predictions

    PubMed Central

    Potter, Gail E.; Smieszek, Timo; Sailer, Kerstin

    2015-01-01

    Face-to-face social contacts are potentially important transmission routes for acute respiratory infections, and understanding the contact network can improve our ability to predict, contain, and control epidemics. Although workplaces are important settings for infectious disease transmission, few studies have collected workplace contact data and estimated workplace contact networks. We use contact diaries, architectural distance measures, and institutional structures to estimate social contact networks within a Swiss research institute. Some contact reports were inconsistent, indicating reporting errors. We adjust for this with a latent variable model, jointly estimating the true (unobserved) network of contacts and duration-specific reporting probabilities. We find that contact probability decreases with distance, and that research group membership, role, and shared projects are strongly predictive of contact patterns. Estimated reporting probabilities were low only for 0–5 min contacts. Adjusting for reporting error changed the estimate of the duration distribution, but did not change the estimates of covariate effects and had little effect on epidemic predictions. Our epidemic simulation study indicates that inclusion of network structure based on architectural and organizational structure data can improve the accuracy of epidemic forecasting models. PMID:26634122

  1. Social mixing in Fiji: Who-eats-with-whom contact patterns and the implications of age and ethnic heterogeneity for disease dynamics in the Pacific Islands.

    PubMed

    Watson, Conall H; Coriakula, Jeremaia; Ngoc, Dung Tran Thi; Flasche, Stefan; Kucharski, Adam J; Lau, Colleen L; Thieu, Nga Tran Vu; le Polain de Waroux, Olivier; Rawalai, Kitione; Van, Tan Trinh; Taufa, Mere; Baker, Stephen; Nilles, Eric J; Kama, Mike; Edmunds, W John

    2017-01-01

    Empirical data on contact patterns can inform dynamic models of infectious disease transmission. Such information has not been widely reported from Pacific islands, nor strongly multi-ethnic settings, and few attempts have been made to quantify contact patterns relevant for the spread of gastrointestinal infections. As part of enteric fever investigations, we conducted a cross-sectional survey of the general public in Fiji, finding that within the 9,650 mealtime contacts reported by 1,814 participants, there was strong like-with-like mixing by age and ethnicity, with higher contact rates amongst iTaukei than non-iTaukei Fijians. Extra-domiciliary lunchtime contacts follow these mixing patterns, indicating the overall data do not simply reflect household structures. Inter-ethnic mixing was most common amongst school-age children. Serological responses indicative of recent Salmonella Typhi infection were found to be associated, after adjusting for age, with increased contact rates between meal-sharing iTaukei, with no association observed for other contact groups. Animal ownership and travel within the geographical division were common. These are novel data that identify ethnicity as an important social mixing variable, and use retrospective mealtime contacts as a socially acceptable metric of relevance to enteric, contact and respiratory diseases that can be collected in a single visit to participants. Application of these data to other island settings will enable communicable disease models to incorporate locally relevant mixing patterns in parameterisation.

  2. Social mixing in Fiji: Who-eats-with-whom contact patterns and the implications of age and ethnic heterogeneity for disease dynamics in the Pacific Islands

    PubMed Central

    Coriakula, Jeremaia; Ngoc, Dung Tran Thi; Flasche, Stefan; Kucharski, Adam J.; Lau, Colleen L.; Thieu, Nga Tran Vu; le Polain de Waroux, Olivier; Rawalai, Kitione; Van, Tan Trinh; Taufa, Mere; Baker, Stephen; Nilles, Eric J.; Kama, Mike; Edmunds, W. John

    2017-01-01

    Empirical data on contact patterns can inform dynamic models of infectious disease transmission. Such information has not been widely reported from Pacific islands, nor strongly multi-ethnic settings, and few attempts have been made to quantify contact patterns relevant for the spread of gastrointestinal infections. As part of enteric fever investigations, we conducted a cross-sectional survey of the general public in Fiji, finding that within the 9,650 mealtime contacts reported by 1,814 participants, there was strong like-with-like mixing by age and ethnicity, with higher contact rates amongst iTaukei than non-iTaukei Fijians. Extra-domiciliary lunchtime contacts follow these mixing patterns, indicating the overall data do not simply reflect household structures. Inter-ethnic mixing was most common amongst school-age children. Serological responses indicative of recent Salmonella Typhi infection were found to be associated, after adjusting for age, with increased contact rates between meal-sharing iTaukei, with no association observed for other contact groups. Animal ownership and travel within the geographical division were common. These are novel data that identify ethnicity as an important social mixing variable, and use retrospective mealtime contacts as a socially acceptable metric of relevance to enteric, contact and respiratory diseases that can be collected in a single visit to participants. Application of these data to other island settings will enable communicable disease models to incorporate locally relevant mixing patterns in parameterisation. PMID:29211731

  3. Three-dimensional motion of the uncovertebral joint during head rotation.

    PubMed

    Nagamoto, Yukitaka; Ishii, Takahiro; Iwasaki, Motoki; Sakaura, Hironobu; Moritomo, Hisao; Fujimori, Takahito; Kashii, Masafumi; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2012-10-01

    The uncovertebral joints are peculiar but clinically important anatomical structures of the cervical vertebrae. In the aged or degenerative cervical spine, osteophytes arising from an uncovertebral joint can cause cervical radiculopathy, often necessitating decompression surgery. Although these joints are believed to bear some relationship to head rotation, how the uncovertebral joints work during head rotation remains unclear. The purpose of this study is to elucidate 3D motion of the uncovertebral joints during head rotation. Study participants were 10 healthy volunteers who underwent 3D MRI of the cervical spine in 11 positions during head rotation: neutral (0°) and 15° increments to maximal head rotation on each side (left and right). Relative motions of the cervical spine were calculated by automatically superimposing a segmented 3D MR image of the vertebra in the neutral position over images of each position using the volume registration method. The 3D intervertebral motions of all 10 volunteers were standardized, and the 3D motion of uncovertebral joints was visualized on animations using data for the standardized motion. Inferred contact areas of uncovertebral joints were also calculated using a proximity mapping technique. The 3D animation of uncovertebral joints during head rotation showed that the joints alternate between contact and separation. Inferred contact areas of uncovertebral joints were situated directly lateral at the middle cervical spine and dorsolateral at the lower cervical spine. With increasing angle of rotation, inferred contact areas increased in the middle cervical spine, whereas areas in the lower cervical spine slightly decreased. In this study, the 3D motions of uncovertebral joints during head rotation were depicted precisely for the first time.

  4. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the rail on which it is applied. (b) If a joint bar on Classes 3 through 5 track is cracked, broken... at each joint in Classes 2 through 5 track, and with at least one bolt in Class 1 track. (e) In the... accommodate expansion and contraction due to temperature variations. When no-slip, joint-to-rail contact...

  5. Analysis of muscle activity and ankle joint movement during the side-hop test.

    PubMed

    Yoshida, Masahiro; Taniguchi, Keigo; Katayose, Masaki

    2011-08-01

    Functional performance tests (FPTs) that consist of movements, such as hopping, landing, and cutting, provide useful measurements. Although some tests have been established for kinematic studies of the knee joint, very few tests have been established for the ankle joint. To use the FPT as a test battery for patients with an ankle sprain, it is necessary to document typical patterns of muscle activation and range of motion (ROM) of the ankle joint during FPTs. Therefore, the purpose of this study was to investigate the pattern of the ROM of the ankle inversion/eversion and the muscle activity of the peroneus longus muscle (PL) and the tibial anterior muscle (TA) in normal subjects during the side-hop test. To emphasize the characteristics of ROM and electromyography (EMG) at each phase, the side-hop tests were divided into 4 phases: lateral-hop contact phase (LC), lateral-hop flight phase (LF), medial hop contact phase (MC), and medial hop flight phase (MF), and the ROM of ankle inversion/eversion, a peak angle of ankle inversion, and Integral EMG (IEMG) of PL and TA compared among 4 phases. Fifteen male subjects with no symptoms of ankle joint problems participated in this research. The ROM of ankle inversion/eversion during the side-hop test was 27 ± 3.8° (mean ± SD), and there was a significant difference in the ROM of ankle inversion/eversion among 4 phases (p < 0.05). The phase in which the widest ROM was presented was the MF. A peak angle of the ankle inversion at MC was significantly greater than at LC and MF (p <0.05). A peak angle of the ankle inversion at LF was significantly greater than at LC and MF. The PL remained contracting with 50-160% of maximal voluntary contraction (MVC). The IEMGs of PL in both the contact phases were significantly greater than in both the flight phases (p < 0.05). In addition, the PL activity at LC was significantly greater than at MC. The TA remained contracting at 50-80% of MVC through the side-hop test. The IEMG of TA at

  6. Change in knee contact force with simulated change in body weight.

    PubMed

    Knarr, Brian A; Higginson, Jill S; Zeni, Joseph A

    2016-02-01

    The relationship between obesity, weight gain and progression of knee osteoarthritis is well supported, suggesting that excessive joint loading may be a mechanism responsible for cartilage deterioration. Examining the influence of weight gain on joint compressive forces is difficult, as both muscles and ground reaction forces can have a significant impact on the forces experienced during gait. While previous studies have examined the relationship between body weight and knee forces, these studies have used models that were not validated using experimental data. Therefore, the objective of this study was to evaluate the relationship between changes in body weight and changes in knee joint contact forces for an individual's gait pattern using musculoskeletal modeling that is validated against known internal compressive forces. Optimal weighting constants were determined for three subjects to generate valid predictions of knee contact forces (KCFs) using in vivo data collection with instrumented total knee arthroplasty. A total of five simulations per walking trial were generated for each subject, from 80% to 120% body weight in 10% increments, resulting in 50 total simulations. The change in peak KCF with respect to body weight was found to be constant and subject-specific, predominantly determined by the peak force during the baseline condition at 100% body weight. This relationship may be further altered by any change in kinematics or body mass distribution that may occur as a result of a change in body weight or exercise program.

  7. Development of a contact heat exchanger for a constructable radiator system

    NASA Technical Reports Server (NTRS)

    Howell, H. R.

    1983-01-01

    A development program for a contact heat exchanger to be used to transfer heat from a spacecraft coolant loop to a heat pipe radiator is described. The contact heat exchanger provides for a connectable/disconnectable joint which allows for on-orbit assembly of the radiator system and replacement or exchange of radiator panels for repair and maintenance. The contact heat exchanger does not require the transfer of fluid across the joint; the spacecraft coolant loop remains contained in an all welded system with no static or dynamic fluid seals. The contact interface is also "dry' with no conductive grease or interstitial material required.

  8. Biomechanical effects of robot assisted walking on knee joint kinematics and muscle activation pattern.

    PubMed

    Thangavel, Pavithra; Vidhya, S; Li, Junhua; Chew, Effie; Bezerianos, Anastasios; Yu, Haoyong

    2017-07-01

    Since manual rehabilitation therapy can be taxing for both the patient and the physiotherapist, a gait rehabilitation robot has been built to reduce the physical strain and increase the efficacy of the rehabilitation therapy. The prototype of the gait rehabilitation robot is designed to provide assistance while walking for patients with abnormal gait pattern and it can also be used for rehabilitation therapy to restore an individual's normal gait pattern by aiding motor recovery. The Gait Rehabilitation Robot uses gait event based synchronization, which enables the exoskeleton to provide synchronous assistance during walking that aims to reduce the lower-limb muscle activation. This study emphasizes on the biomechanical effects of assisted walking on the lower limb by analyzing the EMG signal, knee joint kinematics data that was collected from the right leg during the various experimental conditions. The analysis of the measured data shows an improved knee joint trajectory and reduction in muscle activity with assistance. The result of this study does not only assess the functionality of the exoskeleton but also provides a profound understanding of the human-robot interaction by studying the effects of assistance on the lower limb.

  9. Some aspects of frictional measurements in hip joint simulators.

    PubMed

    Unsworth, Anthony

    2016-05-01

    The measurement of friction in artificial hip joints can lead to the knowledge of the lubrication mechanisms occurring in the joints. However, the measurement of friction, particularly in spherical contacts, is not always straightforward. The important loading and kinematic features must be appropriate and the friction must be measured in the correct plane. Even defining a coefficient of friction is difficult with spherical contacts as friction acts at different moment arms throughout the contact area. Thus, the generated frictional torques depend on the pressure distribution of the contact and the moment arms at which this pressure acts. The pressure distribution depends on the material properties, the surface entraining velocities, the joint diameters, and the clearance between the two surfaces of the ball and socket joint. Equally measuring friction is very taxing for machines which are applying very high loads. Slight misalignments of the application of these loads can produce torques which are very much greater than the frictional torques that we are trying to measure. This article attempts to share the thoughts behind over 40 years of measuring friction in artificial joints using the Durham Friction Simulators. This has led to accrued consistency of measurement and a robust scientific design rationale to understand the nature of friction in these spherical contacts. It also impacts on how to obtain accurate measurements as well as on the understanding of where the difficult issues lie and how to overcome them. © IMechE 2016.

  10. Thermal resistance of pressed contacts of aluminum and niobium at liquid helium temperatures

    DOE PAGES

    Dhuley, R. C.; Geelhoed, M. I.; Thangaraj, J. C. T.

    2018-06-15

    Here, we examine the resistance to heat flow across contacts of mechanically pressed aluminum and niobium near liquid helium temperatures for designing a thermally conducting joint of aluminum and superconducting niobium. Measurements in the temperature range of 3.5 K to 5.5 K show the thermal contact resistance to grow as a near-cubic function of decreasing temperature, indicating phonons to be the primary heat carriers across the interface. In the 4 kN to 14 kN range of pressing force the contact resistance shows linear drop with the increasing force, in agreement with the model of micro-asperity plastic deformation at pressed contacts.more » Several thermal contact resistance models as well as the phonon diffuse mismatch model of interface thermal resistance are compared with the experimental data. The diffuse mismatch model shows closest agreement. The joints are further augmented with thin foil of indium, which lowers the joint resistance by an order of magnitude. The developed joint has nearly 1 K*cm2/W of thermal resistance at 4.2 K, is demountable, and free of the thermally resistive interfacial alloy layer that typically exists at welded, casted, or soldered joints of dissimilar metals.« less

  11. Thermal resistance of pressed contacts of aluminum and niobium at liquid helium temperatures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhuley, R. C.; Geelhoed, M. I.; Thangaraj, J. C. T.

    Here, we examine the resistance to heat flow across contacts of mechanically pressed aluminum and niobium near liquid helium temperatures for designing a thermally conducting joint of aluminum and superconducting niobium. Measurements in the temperature range of 3.5 K to 5.5 K show the thermal contact resistance to grow as a near-cubic function of decreasing temperature, indicating phonons to be the primary heat carriers across the interface. In the 4 kN to 14 kN range of pressing force the contact resistance shows linear drop with the increasing force, in agreement with the model of micro-asperity plastic deformation at pressed contacts.more » Several thermal contact resistance models as well as the phonon diffuse mismatch model of interface thermal resistance are compared with the experimental data. The diffuse mismatch model shows closest agreement. The joints are further augmented with thin foil of indium, which lowers the joint resistance by an order of magnitude. The developed joint has nearly 1 K*cm2/W of thermal resistance at 4.2 K, is demountable, and free of the thermally resistive interfacial alloy layer that typically exists at welded, casted, or soldered joints of dissimilar metals.« less

  12. Characteristics of human encounters and social mixing patterns relevant to infectious diseases spread by close contact: a survey in Southwest Uganda.

    PubMed

    le Polain de Waroux, O; Cohuet, S; Ndazima, D; Kucharski, A J; Juan-Giner, A; Flasche, S; Tumwesigye, E; Arinaitwe, R; Mwanga-Amumpaire, J; Boum, Y; Nackers, F; Checchi, F; Grais, R F; Edmunds, W J

    2018-04-11

    Quantification of human interactions relevant to infectious disease transmission through social contact is central to predict disease dynamics, yet data from low-resource settings remain scarce. We undertook a social contact survey in rural Uganda, whereby participants were asked to recall details about the frequency, type, and socio-demographic characteristics of any conversational encounter that lasted for ≥5 min (henceforth defined as 'contacts') during the previous day. An estimate of the number of 'casual contacts' (i.e. < 5 min) was also obtained. In total, 566 individuals were included in the study. On average participants reported having routine contact with 7.2 individuals (range 1-25). Children aged 5-14 years had the highest frequency of contacts and the elderly (≥65 years) the fewest (P < 0.001). A strong age-assortative pattern was seen, particularly outside the household and increasingly so for contacts occurring further away from home. Adults aged 25-64 years tended to travel more often and further than others, and males travelled more frequently than females. Our study provides detailed information on contact patterns and their spatial characteristics in an African setting. It therefore fills an important knowledge gap that will help more accurately predict transmission dynamics and the impact of control strategies in such areas.

  13. Does expert knowledge improve automatic probabilistic classification of gait joint motion patterns in children with cerebral palsy?

    PubMed Central

    Papageorgiou, Eirini; Nieuwenhuys, Angela; Desloovere, Kaat

    2017-01-01

    Background This study aimed to improve the automatic probabilistic classification of joint motion gait patterns in children with cerebral palsy by using the expert knowledge available via a recently developed Delphi-consensus study. To this end, this study applied both Naïve Bayes and Logistic Regression classification with varying degrees of usage of the expert knowledge (expert-defined and discretized features). A database of 356 patients and 1719 gait trials was used to validate the classification performance of eleven joint motions. Hypotheses Two main hypotheses stated that: (1) Joint motion patterns in children with CP, obtained through a Delphi-consensus study, can be automatically classified following a probabilistic approach, with an accuracy similar to clinical expert classification, and (2) The inclusion of clinical expert knowledge in the selection of relevant gait features and the discretization of continuous features increases the performance of automatic probabilistic joint motion classification. Findings This study provided objective evidence supporting the first hypothesis. Automatic probabilistic gait classification using the expert knowledge available from the Delphi-consensus study resulted in accuracy (91%) similar to that obtained with two expert raters (90%), and higher accuracy than that obtained with non-expert raters (78%). Regarding the second hypothesis, this study demonstrated that the use of more advanced machine learning techniques such as automatic feature selection and discretization instead of expert-defined and discretized features can result in slightly higher joint motion classification performance. However, the increase in performance is limited and does not outweigh the additional computational cost and the higher risk of loss of clinical interpretability, which threatens the clinical acceptance and applicability. PMID:28570616

  14. First contact diagnosis and management of contact lens-related complications.

    PubMed

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  15. Lower limb joint motion during a cross cutting movement differs in individuals with and without chronic ankle instability.

    PubMed

    Koshino, Yuta; Yamanaka, Masanori; Ezawa, Yuya; Ishida, Tomoya; Kobayashi, Takumi; Samukawa, Mina; Saito, Hiroshi; Takeda, Naoki

    2014-11-01

    To compare the kinematics of lower limb joints between individuals with and without chronic ankle instability (CAI) during cross-turn and -cutting movements. Cross-sectional study. Motion analysis laboratory. Twelve subjects with CAI and twelve healthy controls. Hip flexion, adduction, and internal rotation, knee flexion, and ankle dorsiflexion and inversion angles were calculated in the 200 ms before initial ground contact and from initial ground contact to toe-off (stance phase) in a cross-turn movement during gait and a cross-cutting movement from a forward jump, and compared across the two groups. In the cross-cutting movement, the CAI group exhibited greater hip and knee flexion than the control group during the stance phase, and more hip abduction during the period before initial contact and the stance phase. In the cross-turn movement the joint kinematics were similar in the two groups. CAI subjects exhibited an altered pattern of the proximal joint kinematics during a cross-cutting movement. It is important for clinicians to assess the function of the hip and knee as well as the ankle, and to incorporate coordination training for the entire lower limb into rehabilitation after lateral ankle sprains. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Lower limb muscle co-contraction and joint loading of flip-flops walking in male wearers

    PubMed Central

    Chen, Tony Lin-Wei; Wong, Duo Wai-Chi; Xu, Zhi; Tan, Qitao; Wang, Yan; Luximon, Ameersing

    2018-01-01

    Flip-flops may change walking gait pattern, increase muscle activity and joint loading, and predispose wearers to foot problems, despite that quantitative evidence is scarce. The purpose of this study was to examine the lower limb muscle co-contraction and joint contact force in flip-flops gait, and compare with those of barefoot and sports shoes walking. Ten healthy males were instructed to perform over-ground walking at self-selected speed under three footwear conditions: 1) barefoot, 2) sports shoes, and 3) thong-type flip-flops. Kinematic, kinetic and EMG data were collected and input to a musculoskeletal model to estimate muscle force and joint force. One-way repeated measures ANOVA was conducted to compare footwear conditions. It was hypothesized that flip-flops would induce muscle co-contraction and produce different gait kinematics and kinetics. Our results demonstrated that the musculoskeletal model estimation had a good temporal consistency with the measured EMG. Flip-flops produced significantly lower walking speed, higher ankle and subtalar joint range of motion, and higher shear ankle joint contact force than sports shoes (p < 0.05). There were no significant differences between flip-flops and barefoot conditions in terms of muscle co-contraction index, joint kinematics, and joint loading of the knee and ankle complex (p > 0.05). The variance in walking speed and footwear design may be the two major factors that resulted in the comparable joint biomechanics in flip-flops and barefoot walking. From this point of view, whether flip-flops gait is potentially harmful to foot health remains unclear. Given that shod walking is more common than barefoot walking on a daily basis, sports shoes with close-toe design may be a better footwear option than flip-flops for injury prevention due to its constraint on joint motion and loading. PMID:29561862

  17. Lower limb muscle co-contraction and joint loading of flip-flops walking in male wearers.

    PubMed

    Chen, Tony Lin-Wei; Wong, Duo Wai-Chi; Xu, Zhi; Tan, Qitao; Wang, Yan; Luximon, Ameersing; Zhang, Ming

    2018-01-01

    Flip-flops may change walking gait pattern, increase muscle activity and joint loading, and predispose wearers to foot problems, despite that quantitative evidence is scarce. The purpose of this study was to examine the lower limb muscle co-contraction and joint contact force in flip-flops gait, and compare with those of barefoot and sports shoes walking. Ten healthy males were instructed to perform over-ground walking at self-selected speed under three footwear conditions: 1) barefoot, 2) sports shoes, and 3) thong-type flip-flops. Kinematic, kinetic and EMG data were collected and input to a musculoskeletal model to estimate muscle force and joint force. One-way repeated measures ANOVA was conducted to compare footwear conditions. It was hypothesized that flip-flops would induce muscle co-contraction and produce different gait kinematics and kinetics. Our results demonstrated that the musculoskeletal model estimation had a good temporal consistency with the measured EMG. Flip-flops produced significantly lower walking speed, higher ankle and subtalar joint range of motion, and higher shear ankle joint contact force than sports shoes (p < 0.05). There were no significant differences between flip-flops and barefoot conditions in terms of muscle co-contraction index, joint kinematics, and joint loading of the knee and ankle complex (p > 0.05). The variance in walking speed and footwear design may be the two major factors that resulted in the comparable joint biomechanics in flip-flops and barefoot walking. From this point of view, whether flip-flops gait is potentially harmful to foot health remains unclear. Given that shod walking is more common than barefoot walking on a daily basis, sports shoes with close-toe design may be a better footwear option than flip-flops for injury prevention due to its constraint on joint motion and loading.

  18. Close To You? How Parent–Adult Child Contact Is Influenced by Family Patterns

    PubMed Central

    Spitze, Glenna; Ward, Russell A.; Zhuo, Yue (Angela)

    2016-01-01

    Objectives. Intergenerational contacts occur in the context of other family relationships. We examine how in-person contacts among parents and all adult children affect each other, focusing on proximity and other predictors to assess whether and how visiting is correlated across adult children. Methods. We use a modeling approach derived from an adaptation of multilevel models to provide a convenient mechanism by which to write child-specific equations, each with its own set of predictors, and wherein one child’s attribute values can be attached to other children’s records. Results. We find that parent–adult child visiting is positively correlated across siblings, but the frequency of visiting within families is not directly reciprocated. Rather, visiting responds to common family factors. Visiting declines with distance, but there are strong discontinuities in the effect. Distance between parents and a focal child is positively associated with visiting with other children. Discussion. The empirical patterns we report can be framed within enhancement and compensation models. Positive correlations and cross-sibling interactions that juxtapose levels of visiting against not seeing a child in last 12 months are consistent with the enhancement model. The cross-sibling interaction for distance, whereby one child’s farther distance leads to more visits reported with others, provides evidence of a countervailing, though, weaker, pattern of compensation for proximity. PMID:26024669

  19. Influence of lateral and in-depth metal segregation on the patterning of ohmic contacts for GaN-based devices

    NASA Astrophysics Data System (ADS)

    Redondo-Cubero, A.; Vázquez, L.; Alves, L. C.; Corregidor, V.; Romero, M. F.; Pantellini, A.; Lanzieri, C.; Muñoz, E.

    2014-05-01

    The lateral and in-depth metal segregation of Au/Ni/Al/Ti ohmic contacts for GaN-based high electron mobility transistors were analysed as a function of the Al barrier's thickness (d). The surface of the contacts, characterized by atomic force and scanning electron microscopy, shows a transition from a fractal network of rough and complex island-like structures towards smoother and cauliflower-like fronts with increasing d. Rutherford backscattering spectrometry and energy dispersive x-ray spectroscopy (EDXS) at different energies were used to confirm the in-depth intermixing of the metals relevant for the final contact resistance. EDXS mapping reveals a significant lateral segregation too, where the resulting patterns depend on two competing NiAlx and AuAlx phases, the intermixing being controlled by the available amount of Al. The optimum ohmic resistance is not affected by the patterning process, but is mainly dependent on the partial interdiffusion of the metals.

  20. Host contact and shedding patterns clarify variation in pathogen exposure and transmission in threatened tortoise Gopherus agassizii: implications for disease modelling and management

    USGS Publications Warehouse

    Aiello, Christina M.; Nussear, Kenneth E.; Esque, Todd C.; Emblidge, Patrick G.; Sah, Pratha; Bansal, Shweta; Hudson, Peter J.

    2016-01-01

    Mean field models may misrepresent natural transmission patterns in this and other populations depending on the distribution of high-risk contact and shedding events. Rapid outbreaks in generally solitary species may result from changes to their naturally low-risk contact patterns or due to increases in the frequency of severe infections or super-shedding events – population characteristics that should be further investigated to develop effective management strategies.

  1. Foot Placement Characteristics and Plantar Pressure Distribution Patterns during Stepping on Ground in Neonates

    PubMed Central

    Sylos-Labini, F.; Magnani, S.; Cappellini, G.; La Scaleia, V.; Fabiano, A.; Picone, S.; Paolillo, P.; Di Paolo, A.; Lacquaniti, F.; Ivanenko, Y.

    2017-01-01

    Stepping on ground can be evoked in human neonates, though it is rather irregular and stereotyped heel-to-toe roll-over pattern is lacking. Such investigations can provide insights into the role of contact- or load-related proprioceptive feedback during early development of locomotion. However, the detailed characteristics of foot placements and their association with motor patterns are still incompletely documented. We elicited stepping in 33 neonates supported on a table. Unilateral limb kinematics, bilateral plantar pressure distribution and EMG activity from up to 11 ipsilateral leg muscles were recorded. Foot placement characteristics in neonates showed a wide variation. In ~25% of steps, the swinging foot stepped onto the contralateral foot due to generally small step width. In the remaining steps with separate foot placements, the stance phase could start with forefoot (28%), midfoot (47%), or heel (25%) touchdowns. Despite forefoot or heel initial contacts, the kinematic and loading patterns markedly differed relatively to toe-walking or adult-like two-peaked vertical force profile. Furthermore, while the general stepping parameters (cycle duration, step length, range of motion of proximal joints) were similar, the initial foot contact was consistently associated with specific center-of-pressure excursion, range of motion in the ankle joint, and the center-of-activity of extensor muscles (being shifted by ~5% of cycle toward the end of stance in the “heel” relative to “forefoot” condition). In sum, we found a variety of footfall patterns in conjunction with associated changes in motor patterns. These findings suggest the potential contribution of load-related proprioceptive feedback and/or the expression of variations in the locomotor program already during early manifestations of stepping on ground in human babies. PMID:29066982

  2. Enhanced End-Contacts by Helium Ion Bombardment to Improve Graphene-Metal Contacts

    PubMed Central

    Jia, Kunpeng; Su, Yajuan; Zhan, Jun; Shahzad, Kashif; Zhu, Huilong; Zhao, Chao; Luo, Jun

    2016-01-01

    Low contact resistance between graphene and metals is of paramount importance to fabricate high performance graphene-based devices. In this paper, the impact of both defects induced by helium ion (He+) bombardment and annealing on the contact resistance between graphene and various metals (Ag, Pd, and Pt) were systematically explored. It is found that the contact resistances between all metals and graphene are remarkably reduced after annealing, indicating that not only chemically adsorbed metal (Pd) but also physically adsorbed metals (Ag and Pt) readily form end-contacts at intrinsic defect locations in graphene. In order to further improve the contact properties between Ag, Pd, and Pt metals and graphene, a novel method in which self-aligned He+ bombardment to induce exotic defects in graphene and subsequent thermal annealing to form end-contacts was proposed. By using this method, the contact resistance is reduced significantly by 15.1% and 40.1% for Ag/graphene and Pd/graphene contacts with He+ bombardment compared to their counterparts without He+ bombardment. For the Pt/graphene contact, the contact resistance is, however, not reduced as anticipated with He+ bombardment and this might be ascribed to either inappropriate He+ bombardment dose, or inapplicable method of He+ bombardment in reducing contact resistance for Pt/graphene contact. The joint efforts of as-formed end-contacts and excess created defects in graphene are discussed as the cause responsible for the reduction of contact resistance. PMID:28335286

  3. Low-Friction, High-Stiffness Joint for Uniaxial Load Cell

    NASA Technical Reports Server (NTRS)

    Lewis, James L.; Le, Thang; Carroll, Monty B.

    2007-01-01

    A universal-joint assembly has been devised for transferring axial tension or compression to a load cell. To maximize measurement accuracy, the assembly is required to minimize any moments and non-axial forces on the load cell and to exhibit little or no hysteresis. The requirement to minimize hysteresis translates to a requirement to maximize axial stiffness (including minimizing backlash) and a simultaneous requirement to minimize friction. In practice, these are competing requirements, encountered repeatedly in efforts to design universal joints. Often, universal-joint designs represent compromises between these requirements. The improved universal-joint assembly contains two universal joints, each containing two adjustable pairs of angular-contact ball bearings. One might be tempted to ask why one could not use simple ball-and-socket joints rather than something as complex as universal joints containing adjustable pairs of angularcontact ball bearings. The answer is that ball-and-socket joints do not offer sufficient latitude to trade stiffness versus friction: the inevitable result of an attempt to make such a trade in a ball-and-socket joint is either too much backlash or too much friction. The universal joints are located at opposite ends of an axial subassembly that contains the load cell. The axial subassembly includes an axial shaft, an axial housing, and a fifth adjustable pair of angular-contact ball bearings that allows rotation of the axial housing relative to the shaft. The preload on each pair of angular-contact ball bearings can be adjusted to obtain the required stiffness with minimal friction, tailored for a specific application. The universal joint at each end affords two degrees of freedom, allowing only axial force to reach the load cell regardless of application of moments and non-axial forces. The rotational joint on the axial subassembly affords a fifth degree of freedom, preventing application of a torsion load to the load cell.

  4. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    PubMed

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  5. Computational Modelling and Movement Analysis of Hip Joint with Muscles

    NASA Astrophysics Data System (ADS)

    Siswanto, W. A.; Yoon, C. C.; Salleh, S. Md.; Ngali, M. Z.; Yusup, Eliza M.

    2017-01-01

    In this study, the model of hip joint and the main muscles are modelled by finite elements. The parts included in the model are hip joint, hemi pelvis, gluteus maximus, quadratus femoris and gamellus inferior. The materials that used in these model are isotropic elastic, Mooney Rivlin and Neo-hookean. The hip resultant force of the normal gait and stair climbing are applied on the model of hip joint. The responses of displacement, stress and strain of the muscles are then recorded. FEBio non-linear solver for biomechanics is employed to conduct the simulation of the model of hip joint with muscles. The contact interfaces that used in this model are sliding contact and tied contact. From the analysis results, the gluteus maximus has the maximum displacement, stress and strain in the stair climbing. Quadratus femoris and gamellus inferior has the maximum displacement and strain in the normal gait however the maximum stress in the stair climbing. Besides that, the computational model of hip joint with muscles is produced for research and investigation platform. The model can be used as a visualization platform of hip joint.

  6. Stress analysis method for clearance-fit joints with bearing-bypass loads

    NASA Technical Reports Server (NTRS)

    Naik, R. A.; Crews, J. H., Jr.

    1989-01-01

    Within a multi-fastener joint, fastener holes may be subjected to the combined effects of bearing loads and loads that bypass the hole to be reacted elsewhere in the joint. The analysis of a joint subjected to search combined bearing and bypass loads is complicated by the usual clearance between the hole and the fastener. A simple analysis method for such clearance-fit joints subjected to bearing-bypass loading has been developed in the present study. It uses an inverse formulation with a linear elastic finite-element analysis. Conditions along the bolt-hole contact arc are specified by displacement constraint equations. The present method is simple to apply and can be implemented with most general purpose finite-element programs since it does not use complicated iterative-incremental procedures. The method was used to study the effects of bearing-bypass loading on bolt-hole contact angles and local stresses. In this study, a rigid, frictionless bolt was used with a plate having the properties of a quasi-isotropic graphite/epoxy laminate. Results showed that the contact angle as well as the peak stresses around the hole and their locations were strongly influenced by the ratio of bearing and bypass loads. For single contact, tension and compression bearing-bypass loading had opposite effects on the contact angle. For some compressive bearing-bypass loads, the hole tended to close on the fastener leading to dual contact. It was shown that dual contact reduces the stress concentration at the fastener and would, therefore, increase joint strength in compression. The results illustrate the general importance of accounting for bolt-hole clearance and contact to accurately compute local bolt-hole stresses for combined bearings and bypass loading.

  7. The Joint Effect of Bias Awareness and Self-Reported Prejudice on Intergroup Anxiety and Intentions for Intergroup Contact

    PubMed Central

    Perry, Sylvia P.; Dovidio, John F.; Murphy, Mary C.; van Ryn, Michelle

    2015-01-01

    Two correlational studies investigated the joint effect of Bias Awareness—a new individual difference measure that assesses Whites’ awareness and concern about their propensity to be biased—and prejudice on Whites’ intergroup anxiety and intended intergroup contact. Using a community sample (Study 1), we found the predicted Bias Awareness × Prejudice interaction. Prejudice was more strongly related to interracial anxiety among those high (vs. low) in Bias Awareness. Study 2 investigated potential behavioral consequences in an important real world context: medical students’ intentions for working primarily with minority patients. Study 2 replicated the Bias Awareness × Prejudice interaction and further demonstrated that interracial anxiety mediated medical students’ intentions to work with minority populations. PMID:25111552

  8. Reduced complexity of multi-track joint 2-D Viterbi detectors for bit-patterned media recording channel

    NASA Astrophysics Data System (ADS)

    Myint, L. M. M.; Warisarn, C.

    2017-05-01

    Two-dimensional (2-D) interference is one of the prominent challenges in ultra-high density recording system such as bit patterned media recording (BPMR). The multi-track joint 2-D detection technique with the help of the array-head reading can tackle this problem effectively by jointly processing the multiple readback signals from the adjacent tracks. Moreover, it can robustly alleviate the impairments due to track mis-registration (TMR) and media noise. However, the computational complexity of such detectors is normally too high and hard to implement in a reality, even for a few multiple tracks. Therefore, in this paper, we mainly focus on reducing the complexity of multi-track joint 2-D Viterbi detector without paying a large penalty in terms of the performance. We propose a simplified multi-track joint 2-D Viterbi detector with a manageable complexity level for the BPMR's multi-track multi-head (MTMH) system. In the proposed method, the complexity of detector's trellis is reduced with the help of the joint-track equalization method which employs 1-D equalizers and 2-D generalized partial response (GPR) target. Moreover, we also examine the performance of a full-fledged multi-track joint 2-D detector and the conventional 2-D detection. The results show that the simplified detector can perform close to the full-fledge detector, especially when the system faces high media noise, with the significant low complexity.

  9. Inferring a District-Based Hierarchical Structure of Social Contacts from Census Data

    PubMed Central

    Yu, Zhiwen; Liu, Jiming; Zhu, Xianjun

    2015-01-01

    Researchers have recently paid attention to social contact patterns among individuals due to their useful applications in such areas as epidemic evaluation and control, public health decisions, chronic disease research and social network research. Although some studies have estimated social contact patterns from social networks and surveys, few have considered how to infer the hierarchical structure of social contacts directly from census data. In this paper, we focus on inferring an individual’s social contact patterns from detailed census data, and generate various types of social contact patterns such as hierarchical-district-structure-based, cross-district and age-district-based patterns. We evaluate newly generated contact patterns derived from detailed 2011 Hong Kong census data by incorporating them into a model and simulation of the 2009 Hong Kong H1N1 epidemic. We then compare the newly generated social contact patterns with the mixing patterns that are often used in the literature, and draw the following conclusions. First, the generation of social contact patterns based on a hierarchical district structure allows for simulations at different district levels. Second, the newly generated social contact patterns reflect individuals social contacts. Third, the newly generated social contact patterns improve the accuracy of the SEIR-based epidemic model. PMID:25679787

  10. Signaling networks in joint development

    PubMed Central

    Salva, Joanna E.; Merrill, Amy E.

    2016-01-01

    Here we review studies identifying regulatory networks responsible for synovial, cartilaginous, and fibrous joint development. Synovial joints, characterized by the fluid-filled synovial space between the bones, are found in high-mobility regions and are the most common type of joint. Cartilaginous joints unite adjacent bones through either a hyaline cartilage or fibrocartilage intermediate. Fibrous joints, which include the cranial sutures, form a direct union between bones through fibrous connective tissue. We describe how the distinct morphologic and histogenic characteristics of these joint classes are established during embryonic development. Collectively, these studies reveal that despite the heterogeneity of joint strength and mobility, joint development throughout the skeleton utilizes common signaling networks via long-range morphogen gradients and direct cell-cell contact. This suggests that different joint types represent specialized variants of homologous developmental modules. Identifying the unifying aspects of the signaling networks between joint classes allows a more complete understanding of the signaling code for joint formation, which is critical to improving strategies for joint regeneration and repair. PMID:27859991

  11. [Coordination patterns assessed by a continuous measure of joints coupling during upper limb repetitive movements].

    PubMed

    Draicchio, F; Silvetti, A; Ranavolo, A; Iavicoli, S

    2008-01-01

    We analyzed the coordination patterns between elbow, shoulder and trunk in a motor task consisting of reaching out, picking up a cylinder, and transporting it back by using the Dynamical Systems Theory and calculating the continuous relative phase (CRP), a continuous measure of the coupling between two interacting joints. We used an optoelectronic motion analysis system consisting of eight infra-red ray cameras to detect the movements of nine skin-mounted markers. We calculated the root square of the adjusted coefficient of determination, the coefficient of multiple correlation (CMC), in order to investigate the repeatability of the joints coordination. The data confirm that the CNS establishes both synergic (i.e. coupling between shoulder and trunk on the frontal plane) and hierarchical (i.e. coupling between elbow-shoulder-trunk on the horizontal plane) relationships among the available degrees of freedom to overcome the complexity due to motor redundancy. The present study describes a method to investigate the organization of the kinematic degrees of freedom during upper limb multi-joint motor tasks that can be useful to assess upper limb repetitive movements.

  12. Effect of Ankle Joint Contact Angle and Ground Contact Time on Depth Jump Performance.

    PubMed

    Phillips, Joshua H; Flanagan, Sean P

    2015-11-01

    Athletes often need to both jump high and get off the ground quickly, but getting off the ground quickly can decrease the vertical ground reaction force (VGRF) impulse, impeding jump height. Energy stored in the muscle-tendon complex during the stretch-shortening cycle (SSC) may mitigate the effects of short ground contact times (GCTs). To take advantage of the SSC, several coaches recommend "attacking" the ground with the foot in a dorsiflexed (DF) position at contact. However, the efficacy of this technique has not been tested. This investigation tested the hypotheses that shorter GCTs would lead to smaller vertical depth jump heights (VDJH), and that this difference could be mitigated by instructing the athletes to land in a DF as opposed to a plantar flexed (PF) foot position. Eighteen healthy junior college athletes performed depth jumps from a 45-cm box onto force platforms under instruction to achieve one of the 2 objectives (maximum jump height [hmax] or minimal GCT [tmin]), with one of the 2 foot conditions (DF or PF). These variations created 4 distinct jump conditions: DF-hmax, DF-tmin, PF-hmax, and PF-tmin. For all variables examined, there were no significant interactions. For all 4 conditions, the ankle was PF during landing, but the DF condition was 28.87% less PF than the PF condition. The tmin conditions had a 23.48% shorter GCT than hmax. There were no significant main effects for jump height. The peak impact force for tmin was 22.14% greater than hmax and 19.11% greater for DF compared with PF conditions. A shorter GCT did not necessitate a smaller jump height, and a less PF foot did not lead to improvements in jump height or contact time during a depth jump from a 45-cm box. The same jump height was attained in less PF and shorter GCT conditions by larger impact forces. To decrease contact time while maintaining jump height, athletes should be instructed to "get off the ground as fast as possible." This cue seems to be more important than foot

  13. Comparison of the social contact patterns among school-age children in specific seasons, locations, and times.

    PubMed

    Luh, Dih-Ling; You, Zhi-Shin; Chen, Szu-Chieh

    2016-03-01

    Social contact patterns among school-age children play an important role in the epidemiology of infectious disease. This study explored how people interact in specific seasons (flu season and non-flu season), environmental settings (city and county), and times (weekend and weekday). We conducted a survey of junior high school students (grades 7-8) using an established questionnaire during May-June 2013 and December 2013. The sample size with pair-wise comparisons for the times (weekday/weekend) and stratification by location and seasons were 75, 87, 105 and 106, respectively. The sample size with pair-wise comparisons for the seasons (flu/non-flu) and stratification by location were 54 and 83, respectively. Conversation and skin-to-skin contact behaviors were surveyed through diary-based questionnaires, of which 665 valid questionnaires were returned. There was no difference in the number of contacts during the flu and non-flu seasons, with averages of 16.3 (S.D.=12.9) and 14.6 (S.D.=9.5) people, respectively. However, statistical analysis showed that the average number of contacts in Taichung City and Yilan County were significantly different (p<0.001). Weekdays were associated with 23-28% more contacts than weekend days during both the non-flu and flu seasons (p<0.001) (Wilcoxon signed-rank test). Our work has important implications for the dynamic modeling of infectious diseases and performance analysis of human contact numbers and contact characteristics for schoolchildren in specific seasons, places, and times. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Active tactile sampling by an insect in a step-climbing paradigm

    PubMed Central

    Krause, André F.; Dürr, Volker

    2012-01-01

    Many insects actively explore their near-range environment with their antennae. Stick insects (Carausius morosus) rhythmically move their antennae during walking and respond to antennal touch by repetitive tactile sampling of the object. Despite its relevance for spatial orientation, neither the spatial sampling patterns nor the kinematics of antennation behavior in insects are understood. Here we investigate unrestrained bilateral sampling movements during climbing of steps. The main objectives are: (1) How does the antennal contact pattern relate to particular object features? (2) How are the antennal joints coordinated during bilateral tactile sampling? We conducted motion capture experiments on freely climbing insects, using steps of different height. Tactile sampling was analyzed at the level of antennal joint angles. Moreover, we analyzed contact patterns on the surfaces of both the obstacle and the antenna itself. Before the first contact, both antennae move in a broad, mostly elliptical exploratory pattern. After touching the obstacle, the pattern switches to a narrower and faster movement, caused by higher cycle frequencies and lower cycle amplitudes in all joints. Contact events were divided into wall- and edge-contacts. Wall contacts occurred mostly with the distal third of the flagellum, which is flexible, whereas edge contacts often occurred proximally, where the flagellum is stiff. The movement of both antennae was found to be coordinated, exhibiting bilateral coupling of functionally analogous joints [e.g., left head-scape (HS) joint with right scape-pedicel (SP) joint] throughout tactile sampling. In comparison, bilateral coupling between homologous joints (e.g., both HS joints) was significantly weaker. Moreover, inter-joint coupling was significantly weaker during the contact episode than before. In summary, stick insects show contact-induced changes in frequency, amplitude and inter-joint coordination during tactile sampling of climbed obstacles

  15. Patients' journeys through total joint replacement: patterns of medication use.

    PubMed

    Johnson, Emma C; Horwood, Jeremy; Gooberman-Hill, Rachael

    2014-06-01

    Medication is used to manage pain that results from both osteoarthritis and total joint replacement (TJR). Research has provided insight into how people living with osteoarthritis use pain relief medication. However, it is not known whether elective TJR affects existing attitudes and behaviours with regard to pain medications. Using qualitative methods, the present study explored patterns of pain relief use around the time of TJR. In-depth face-to-face qualitative interviews were carried out with 24 patients two to four weeks after they had undergone TJR for hip or knee osteoarthritis. Participants were asked to reflect on their use of pain medication pre-surgery, while in hospital and while recovering from their operation at home. Transcripts of the audio-recorded interviews were imported into Atlas.ti® and thematic analysis was used. Attitudes to pain relief medication and their use are not static. Many participants change their use of pain medication around the time of surgery. This shift was influenced by interactions with health professionals and changing views on the acceptability, necessity and value of pain relief in helping to manage an altered pain experience. Understanding reasons for medication-taking behaviour during the journey through joint replacement may be helpful to health professionals. Health professionals have a fundamental role to play in challenging or reinforcing different treatment beliefs, which is the basis for effective use of pain relief over the pre- to postoperative period. © 2013 John Wiley & Sons, Ltd.

  16. Muscle optimization techniques impact the magnitude of calculated hip joint contact forces.

    PubMed

    Wesseling, Mariska; Derikx, Loes C; de Groote, Friedl; Bartels, Ward; Meyer, Christophe; Verdonschot, Nico; Jonkers, Ilse

    2015-03-01

    In musculoskeletal modelling, several optimization techniques are used to calculate muscle forces, which strongly influence resultant hip contact forces (HCF). The goal of this study was to calculate muscle forces using four different optimization techniques, i.e., two different static optimization techniques, computed muscle control (CMC) and the physiological inverse approach (PIA). We investigated their subsequent effects on HCFs during gait and sit to stand and found that at the first peak in gait at 15-20% of the gait cycle, CMC calculated the highest HCFs (median 3.9 times peak GRF (pGRF)). When comparing calculated HCFs to experimental HCFs reported in literature, the former were up to 238% larger. Both static optimization techniques produced lower HCFs (median 3.0 and 3.1 pGRF), while PIA included muscle dynamics without an excessive increase in HCF (median 3.2 pGRF). The increased HCFs in CMC were potentially caused by higher muscle forces resulting from co-contraction of agonists and antagonists around the hip. Alternatively, these higher HCFs may be caused by the slightly poorer tracking of the net joint moment by the muscle moments calculated by CMC. We conclude that the use of different optimization techniques affects calculated HCFs, and static optimization approached experimental values best. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Migrating lumbar facet joint cysts.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-04-01

    The majority of lumbar facet joint cysts (LFJCs) are located in the spinal canal, on the medial aspect of the facet joint with characteristic diagnostic features. When they migrate away from the joint of origin, they cause diagnostic problems. In a 7-year period we examined by computed tomography (CT) and magnetic resonance (MR) imaging five unusual cases of facet joint cysts which migrated from the facet joint of origin. Three LFJCs were identified in the right S1 foramen, one in the right L5-S1 neural foramen and one in the left erector spinae and multifidus muscles between the levels of L2-L4 spinous process. Awareness that spinal lesions identified at MRI and CT could be due to migrating facet joint cyst requires a high level of suspicion. The identification of the appositional contact of the cyst and the facet joint needs to be actively sought in the presence of degenerative facet joints.

  18. Ink-Jet Printer Forms Solar-Cell Contacts

    NASA Technical Reports Server (NTRS)

    Alexander, Paul, Jr.; Vest, R. W.; Binford, Don A.; Tweedell, Eric P.

    1988-01-01

    Contacts formed in controllable patterns with metal-based inks. System forms upper metal contact patterns on silicon photovoltaic cells. Uses metallo-organic ink, decomposes when heated, leaving behind metallic, electrically conductive residue in printed area.

  19. The surface geometry of inherited joint and fracture trace patterns resulting from active and passive deformation

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.; Gold, D. P.

    1974-01-01

    Hypothetical models are considered for detecting subsurface structure from the fracture or joint pattern, which may be influenced by the structure and propagated to the surface. Various patterns of an initially orthogonal fracture grid are modeled according to active and passive deformation mechanisms. In the active periclinal structure with a vertical axis, fracture frequency increased both over the dome and basin, and remained constant with decreasing depth to the structure. For passive periclinal features such as a reef or sand body, fracture frequency is determined by the arc of curvature and showed a reduction over the reefmound and increased over the basin.

  20. Care System Versus Transmitted Light Wavefront Pattern of Contact Lenses.

    PubMed

    Chiericati, Stefano; Borghesi, Alessandro; Cozza, Federica; Ferraro, Lorenzo; Acciarri, Maurizio; Farris, Stefano; Tavazzi, Silvia

    2017-05-01

    This article compares the optical performance of soft contact lenses (CLs) treated with multipurpose or hydrogen peroxide care systems. The investigated care systems were (1) 3% hydrogen peroxide solution Oxysept (Abbot Medical Optics, Abbott Park, IL) and (2) multipurpose solution Regard (Vita Research, Ariccia, Italy). Three types of silicone hydrogel CLs were studied (comfilcon A, lotrafilcon B, and balafilcon A), unworn and exposed for 30 times to the solutions, which were replaced every 8 hr. The optical performance of the CLs was evaluated through the on-eye transmitted light wavefront patterns by considering new CLs as references. The surface morphology of the CLs was investigated by scanning electron microscopy. Statistically significant modifications in the range 0.1 to 0.3 μm of Zernicke coefficients and modifications of the root mean square of the wavefront aberration function were found for CLs treated with multipurpose solution, in agreement with the observed modifications of the surface morphology. Statistically significant changes were also found after exposure to the hydrogen peroxide solution, but the variation of the Zernicke coefficients was found lower than 0.1 μm, thus being negligible in CL optical performances. In addition to disinfection ability and ocular surface reactions, CL care systems are different in solution-related CL optical performance. Multipurpose solutions may affect the CL surface morphology with significant modifications of the transmitted light wavefront pattern.

  1. Minimum distraction gap: how much ankle joint space is enough in ankle distraction arthroplasty?

    PubMed

    Fragomen, Austin T; McCoy, Thomas H; Meyers, Kathleen N; Rozbruch, S Robert

    2014-02-01

    The success of ankle distraction arthroplasty relies on the separation of the tibiotalar articular surfaces. The purpose of this study was to find the minimum distraction gap needed to ensure that the tibiotalar joint surfaces would not contact each other with full weight-bearing while under distraction. Circular external fixators were mounted to nine cadaver ankle specimens. Each specimen was then placed into a custom-designed load chamber. Loads of 0, 350, and 700N were applied to the specimen. Radiographic joint space was measured and joint contact pressure was monitored under each load. The external fixator was then sequentially distracted, and the radiographic joint space was measured under the three different loads. The experiment was stopped when there was no joint contact under 700N of load. The radiographic joint space was measured and the initial (undistracted) radiographic joint space was subtracted from it yielding the distraction gap. The minimum distraction gap (mDG) that would provide total unloading was calculated. The average mDG was 2.4 mm (range, 1.6 to 4.0 mm) at 700N of load, 4.4 mm (range, 3.7 to 5.8 mm) at 350N of load, and 4.9 mm (range, 3.7 to 7.0 mm) at 0N of load. These results suggest that if the radiographic joint space of on a standing X-ray of an ankle undergoing distraction arthroplasty shows a minimum of 5.8 mm of DG, then there will be no contact between joint surfaces during full weight-bearing. Therefore, 5 mm of radiographic joint space, as recommended historically, may not be adequate to prevent contact of the articular surfaces during weight-bearing.

  2. In vivo axial humero-ulnar rotation in normal and dysplastic canine elbow joints.

    PubMed

    Rohwedder, Thomas; Fischer, Martin; Böttcher, Peter

    2018-04-01

    To prospectively compare relative axial (internal-external) humero-ulnar rotation in normal and dysplastic canine elbow joints. Six normal elbows (five dogs) and seven joints (six dogs) with coronoid disease were examined. After implantation of 0.8 mm tantalum beads into humerus and ulna, biplanar x-ray movies of the implanted elbows were taken while dogs were walking on a treadmill. Based on the 2D bead coordinates of the synchronized x-ray movies virtual 3D humero-ulnar animations were calculated. Based on these, relative internal-external humero-ulnar rotation was measured over the first third of stance phase and expressed as maximal rotational amplitude. Amplitudes from three consecutive steps were averaged and groupwise compared using an unpaired t-test. In normal elbow joints mean axial relative humero-ulnar rotation was 2.9° (SD 1.1). Dysplastic joints showed a significantly greater rotational amplitude (5.3°, SD 2.0; p = 0.0229, 95% confidence interval 0.4-4.4). Dysplastic elbow joints show greater relative internal-external humero-ulnar rotation compared to normal elbows, which might reflect rotational joint instability. Increased relative internal-external humero-ulnar rotation might alter physiological joint contact and pressure patterns. Future studies are needed to verify if this plays a role in the pathogenesis of medial coronoid disease. Schattauer GmbH.

  3. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

    PubMed

    Leumann, Andre; Fortuna, Rafael; Leonard, Tim; Valderrabano, Victor; Herzog, Walter

    2015-01-01

    The menisci are thought to modulate load transfer and to absorb shocks in the knee joint. No study has experimentally measured the meniscal functions in the intact, in vivo joint loaded by physiologically relevant muscular contractions. Right knee joints of seven New Zealand white rabbits were loaded using isometric contractions of the quadriceps femoris muscles controlled by femoral nerve stimulation. Isometric knee extensor torques at the maximal and two submaximal force levels were performed at knee angles of 70°, 90°, 110°, and 130°. Patellofemoral and tibiofemoral contact areas and pressure distributions were measured using Fuji Presensor film inserted above and below the menisci and also with the menisci removed. Meniscectomy was associated with a decrease in tibiofemoral contact area ranging from 30 to 70% and a corresponding increase in average contact pressures. Contact areas measured below the menisci were consistently larger than those measured on top of the menisci. Contact areas in the patellofemoral joint (PFJ), and peak pressures in tibiofemoral and PFJs, were not affected by meniscectomy. Contact areas and peak pressures in all joints depended crucially on knee joint angle and quadriceps force: The more flexed the knee joint was, the larger were the contact areas and the higher were the peak pressures. In agreement with the literature, removal of the menisci was associated with significant decreases in tibiofemoral contact area and corresponding increases in average contact pressures, but surprisingly, peak pressures remained unaffected, indicating that the function of the menisci is to distribute loads across a greater contact area.

  4. Oxygen-Free Welding Contact Tips

    NASA Technical Reports Server (NTRS)

    Pike, James F.

    1993-01-01

    Contact tips for gas/metal arc welding (GMAW) fabricated from oxygen-free copper. Prototype tips tested in robotic welding, for which application intended. Reduces electrical erosion, increases electrical conductivity, and reduces mechanical wear. Productivity of robotic welding increases while time during welding interrupted for removal and replacement of contact tips minimal. Improves alignment of joints and filler metal, reducing rate of rejection and repair of unacceptable weldments. Utility extends beyond aerospace industry to mass production of various types of hardware, including heavy off-highway construction equipment.

  5. On foundations of discrete element analysis of contact in diarthrodial joints.

    PubMed

    Volokh, K Y; Chao, E Y S; Armand, M

    2007-06-01

    Information about the stress distribution on contact surfaces of adjacent bones is indispensable for analysis of arthritis, bone fracture and remodeling. Numerical solution of the contact problem based on the classical approaches of solid mechanics is sophisticated and time-consuming. However, the solution can be essentially simplified on the following physical grounds. The bone contact surfaces are covered with a layer of articular cartilage, which is a soft tissue as compared to the hard bone. The latter allows ignoring the bone compliance in analysis of the contact problem, i.e. rigid bones are considered to interact through a compliant cartilage. Moreover, cartilage shear stresses and strains can be ignored because of the negligible friction between contacting cartilage layers. Thus, the cartilage can be approximated by a set of unilateral compressive springs normal to the bone surface. The forces in the springs can be computed from the equilibrium equations iteratively accounting for the changing contact area. This is the essence of the discrete element analysis (DEA). Despite the success in applications of DEA to various bone contact problems, its classical formulation required experimental validation because the springs approximating the cartilage were assumed linear while the real articular cartilage exhibited non-linear mechanical response in reported tests. Recent experimental results of Ateshian and his co-workers allow for revisiting the classical DEA formulation and establishing the limits of its applicability. In the present work, it is shown that the linear spring model is remarkably valid within a wide range of large deformations of the cartilage. It is also shown how to extend the classical DEA to the case of strong nonlinearity if necessary.

  6. Ankle and hip postural strategies defined by joint torques

    NASA Technical Reports Server (NTRS)

    Runge, C. F.; Shupert, C. L.; Horak, F. B.; Zajac, F. E.; Peterson, B. W. (Principal Investigator)

    1999-01-01

    Previous studies have identified two discrete strategies for the control of posture in the sagittal plane based on EMG activations, body kinematics, and ground reaction forces. The ankle strategy was characterized by body sway resembling a single-segment-inverted pendulum and was elicited on flat support surfaces. In contrast, the hip strategy was characterized by body sway resembling a double-segment inverted pendulum divided at the hip and was elicited on short or compliant support surfaces. However, biomechanical optimization models have suggested that hip strategy should be observed in response to fast translations on a flat surface also, provided the feet are constrained to remain in contact with the floor and the knee is constrained to remain straight. The purpose of this study was to examine the experimental evidence for hip strategy in postural responses to backward translations of a flat support surface and to determine whether analyses of joint torques would provide evidence for two separate postural strategies. Normal subjects standing on a flat support surface were translated backward with a range of velocities from fast (55 cm/s) to slow (5 cm/s). EMG activations and joint kinematics showed pattern changes consistent with previous experimental descriptions of mixed hip and ankle strategy with increasing platform velocity. Joint torque analyses revealed the addition of a hip flexor torque to the ankle plantarflexor torque during fast translations. This finding indicates the addition of hip strategy to ankle strategy to produce a continuum of postural responses. Hip torque without accompanying ankle torque (pure hip strategy) was not observed. Although postural control strategies have previously been defined by how the body moves, we conclude that joint torques, which indicate how body movements are produced, are useful in defining postural control strategies. These results also illustrate how the biomechanics of the body can transform discrete control

  7. Automated muscle wrapping using finite element contact detection.

    PubMed

    Favre, Philippe; Gerber, Christian; Snedeker, Jess G

    2010-07-20

    Realistic muscle path representation is essential to musculoskeletal modeling of joint function. Algorithms predicting these muscle paths typically rely on a labor intensive predefinition of via points or underlying geometries to guide wrapping for given joint positions. While muscle wrapping using anatomically precise three-dimensional (3D) finite element (FE) models of bone and muscle has been achieved, computational expense and pre-processing associated with this approach exclude its use in applications such as subject-specific modeling. With the intention of combining advantageous features of both approaches, an intermediate technique relying on contact detection capabilities of commercial FE packages is presented. We applied the approach to the glenohumeral joint, and validated the method by comparison against existing experimental data. Individual muscles were modeled as a straight series of deformable beam elements and bones as anatomically precise 3D rigid bodies. Only the attachment locations and a default orientation of the undeformed muscle segment were pre-defined. The joint was then oriented in a static position of interest. The muscle segment free end was then moved along the shortest Euclidean path to its origin on the scapula, wrapping the muscle along bone surfaces by relying on software contact detection. After wrapping for a given position, the resulting moment arm was computed as the perpendicular distance from the line of action vector to the humeral head center of rotation. This approach reasonably predicted muscle length and moment arm for 27 muscle segments when compared to experimental measurements over a wide range of shoulder motion. Artificial via points or underlying contact geometries were avoided, contact detection and multiobject wrapping on the bone surfaces were automatic, and low computational cost permitted wrapping of individual muscles within seconds on a standard desktop PC. These advantages may be valuable for both general

  8. Contact diaries versus wearable proximity sensors in measuring contact patterns at a conference: method comparison and participants' attitudes.

    PubMed

    Smieszek, Timo; Castell, Stefanie; Barrat, Alain; Cattuto, Ciro; White, Peter J; Krause, Gérard

    2016-07-22

    Studies measuring contact networks have helped to improve our understanding of infectious disease transmission. However, several methodological issues are still unresolved, such as which method of contact measurement is the most valid. Further, complete network analysis requires data from most, ideally all, members of a network and, to achieve this, acceptance of the measurement method. We aimed at investigating measurement error by comparing two methods of contact measurement - paper diaries vs. wearable proximity sensors - that were applied concurrently to the same population, and we measured acceptability. We investigated the contact network of one day of an epidemiology conference in September 2014. Seventy-six participants wore proximity sensors throughout the day while concurrently recording their contacts with other study participants in a paper-diary; they also reported on method acceptability. There were 329 contact reports in the paper diaries, corresponding to 199 contacts, of which 130 were noted by both parties. The sensors recorded 316 contacts, which would have resulted in 632 contact reports if there had been perfect concordance in recording. We estimated the probabilities that a contact was reported in a diary as: P = 72 % for <5 min contact duration (significantly lower than the following, p < 0.05), P = 86 % for 5-15 min, P = 89 % for 15-60 min, and P = 94 % for >60 min. The sets of sensor-measured and self-reported contacts had a large intersection, but neither was a subset of the other. Participants' aggregated contact duration was mostly substantially longer in the diary data than in the sensor data. Twenty percent of respondents (>1 reported contact) stated that filling in the diary was too much work, 25 % of respondents reported difficulties in remembering contacts, and 93 % were comfortable having their conference contacts measured by sensors. Reporting and recording were not complete; reporting was

  9. Current practice patterns in conservative thumb CMC joint care: survey results.

    PubMed

    O'Brien, Virginia H; McGaha, Jamie L

    2014-01-01

    Cross-sectional descriptive survey Best practice for conservative clinical care pathways is not well outlined in the literature for patients with thumb carpometacarpal joint (CMCJ) pain. This self-report survey investigated the current practice patterns of assessments and conservative interventions for the painful thumb CMCJ among hand therapists. An online survey was distributed to members of the American Society of Hand Therapists (ASHT). Questions were included about evaluation measures and intervention techniques used for this population. A descriptive analysis was completed of the results. A total of 23.5% of the ASHT membership responded to the survey. Results were categorized using the International Classification of Functioning and Disability domains as a framework. The survey results report varying use of evaluation measures, therapeutic interventions, including orthotic fabrication, joint protection and patient education all therapeutic interventional techniques, and modalities. Therapists use a comprehensive array of evaluation measures and interventions for body functions and structures in the care of thumb CMC pain. In contrast, more consistent use is needed of psychometrically-sound functional outcome measures that show change in activities and participation. This survey highlights areas to employ current evidence, as well as, future research should address environmental factors and personal factors for this population Not applicable. Copyright © 2014 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  10. Cartilage loss patterns within femorotibial contact regions during deep knee bend.

    PubMed

    Michael Johnson, J; Mahfouz, Mohamed R

    2016-06-14

    Osteoarthritis (OA) can alter knee kinematics and stresses. The relationship between cartilage loss in OA and kinematics is unclear, with existing work focusing on static wear and morphology. In this work, femorotibial cartilage maps were coupled with kinematics to investigate the relationship between kinematics and cartilage loss, allowing for more precise treatment and intervention. Cartilage thickness maps were created from healthy and OA subgroups (varus, valgus, and neutral) and mapped to a statistical bone atlas. Video fluoroscopy determined contact regions from 0° to 120° flexion. Varus and valgus subgroups displayed different wear patterns across the range of flexion, with varus knees showing more loss in early flexion and valgus in deeper flexion. For the femur, varus knees had more wear in the medial compartment than neutral or valgus and most wear at both 0° and 20° flexion. In the lateral femoral compartment, the valgus subgroup showed significantly more wear from 20° to 60° flexion as compared to other angles, though varus knees displayed highest magnitude of wear. For the tibia, most medial wear occurred at 0-40° flexion and most lateral occurred after 60° flexion. Knowing more about cartilage changes in OA knees provides insight as to expected wear or stresses on implanted components after arthroplasty. Combining cartilage loss patterns with kinematics allows for pre-surgical intervention and treatments tailored to the patient׳s alignment and kinematics. Reported wear patterns may also serve as a gauge for post-operative loading to be considered when placing implant components. Copyright © 2016. Published by Elsevier Ltd.

  11. The hindlimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R

    2001-01-01

    The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.

  12. Fast Grasp Contact Computation for a Serial Robot

    NASA Technical Reports Server (NTRS)

    Hargrave, Brian (Inventor); Shi, Jianying (Inventor); Diftler, Myron A. (Inventor)

    2015-01-01

    A system includes a controller and a serial robot having links that are interconnected by a joint, wherein the robot can grasp a three-dimensional (3D) object in response to a commanded grasp pose. The controller receives input information, including the commanded grasp pose, a first set of information describing the kinematics of the robot, and a second set of information describing the position of the object to be grasped. The controller also calculates, in a two-dimensional (2D) plane, a set of contact points between the serial robot and a surface of the 3D object needed for the serial robot to achieve the commanded grasp pose. A required joint angle is then calculated in the 2D plane between the pair of links using the set of contact points. A control action is then executed with respect to the motion of the serial robot using the required joint angle.

  13. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  14. Patello-femoral and tibio-femoral contact forces during kicking type of activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engin, A.E.; Tumer, S.T.

    1996-12-31

    In this paper patello-femoral and tibia-femoral contact forces during kicking type of activity is presented by means of a dynamic model of the knee joint which includes tibio-femoral and patello-femoral articulations, and the major ligaments of the joint. The model shows that the patella can be subjected to very large transient patello-femoral contact forces during a strenuous lower limb activity such as kicking even under conditions of small knee-flexion angles.

  15. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.

    PubMed

    Willing, Ryan; King, Graham J W; Johnson, James A

    2015-11-26

    Erosion of articular cartilage is a concern following distal humeral hemiarthroplasty, because native cartilage surfaces are placed in contact with stiff metallic implant components, which causes decreases in contact area and increases in contact stresses. Recently, reverse engineered implants have been proposed which are intended to promote more natural contact mechanics by reproducing the native bone or cartilage shape. In this study, finite element modeling is used in order to calculate changes in cartilage contact areas and stresses following distal humeral hemiarthroplasty with commercially available and reverse engineered implant designs. At the ulna, decreases in contact area were -34±3% (p=0.002), -27±1% (p<0.001) and -14±2% (p=0.008) using commercially available, bone reverse engineered and cartilage reverse engineered designs, respectively. Peak contact stresses increased by 461±57% (p=0.008), 387±127% (p=0.229) and 165±16% (p=0.003). At the radius, decreases in contact area were -21±3% (p=0.013), -13±2% (p<0.006) and -6±1% (p=0.020), and peak contact stresses increased by 75±52% (p>0.999), 241±32% (p=0.010) and 61±10% (p=0.021). Between the three different implant designs, the cartilage reverse engineered design yielded the largest contact areas and lowest contact stresses, but was still unable to reproduce the contact mechanics of the native joint. These findings align with a growing body of evidence indicating that although reverse engineered hemiarthroplasty implants can provide small improvements in contact mechanics when compared with commercially available designs, further optimization of shape and material properties is required in order reproduce native joint contact mechanics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. To what extent is joint and muscle mechanics predicted by musculoskeletal models sensitive to soft tissue artefacts?

    PubMed

    Lamberto, Giuliano; Martelli, Saulo; Cappozzo, Aurelio; Mazzà, Claudia

    2017-09-06

    Musculoskeletal models are widely used to estimate joint kinematics, intersegmental loads, and muscle and joint contact forces during movement. These estimates can be heavily affected by the soft tissue artefact (STA) when input positional data are obtained using stereophotogrammetry, but this aspect has not yet been fully characterised for muscle and joint forces. This study aims to assess the sensitivity to the STA of three open-source musculoskeletal models, implemented in OpenSim. A baseline dataset of marker trajectories was created for each model from experimental data of one healthy volunteer. Five hundred STA realizations were then statistically generated using a marker-dependent model of the pelvis and lower limb artefact and added to the baseline data. The STA׳s impact on the musculoskeletal model estimates was finally quantified using a Monte Carlo analysis. The modelled STA distributions were in line with the literature. Observed output variations were comparable across the three models, and sensitivity to the STA was evident for most investigated quantities. Shape, magnitude and timing of the joint angle and moment time histories were not significantly affected throughout the entire gait cycle, whereas magnitude variations were observed for muscle and joint forces. Ranges of contact force variations differed between joints, with hip variations up to 1.8 times body weight observed. Variations of more than 30% were observed for some of the muscle forces. In conclusion, musculoskeletal simulations using stereophotogrammetry may be safely run when only interested in overall output patterns. Caution should be paid when more accurate estimated values are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Medial knee joint contact force in the intact limb during walking in recently ambulatory service members with unilateral limb loss: a cross-sectional study

    PubMed Central

    Krupenevich, Rebecca L.; Pruziner, Alison L.; Wolf, Erik J.; Schnall, Barri L.

    2017-01-01

    Background Individuals with unilateral lower limb amputation have a high risk of developing knee osteoarthritis (OA) in their intact limb as they age. This risk may be related to joint loading experienced earlier in life. We hypothesized that loading during walking would be greater in the intact limb of young US military service members with limb loss than in controls with no limb loss. Methods Cross-sectional instrumented gait analysis at self-selected walking speeds with a limb loss group (N = 10, age 27 ± 5 years, 170 ± 36 days since last surgery) including five service members with transtibial limb loss and five with transfemoral limb loss, all walking independently with their first prosthesis for approximately two months. Controls (N = 10, age 30 ± 4 years) were service members with no overt demographical risk factors for knee OA. 3D inverse dynamics modeling was performed to calculate joint moments and medial knee joint contact forces (JCF) were calculated using a reduction-based musculoskeletal modeling method and expressed relative to body weight (BW). Results Peak JCF and maximum JCF loading rate were significantly greater in limb loss (184% BW, 2,469% BW/s) vs. controls (157% BW, 1,985% BW/s), with large effect sizes. Results were robust to probabilistic perturbations to the knee model parameters. Discussion Assuming these data are reflective of joint loading experienced in daily life, they support a “mechanical overloading” hypothesis for the risk of developing knee OA in the intact limb of limb loss subjects. Examination of the evolution of gait mechanics, joint loading, and joint health over time, as well as interventions to reduce load or strengthen the ability of the joint to withstand loads, is warranted. PMID:28168120

  18. An eye tracking system for monitoring face scanning patterns reveals the enhancing effect of oxytocin on eye contact in common marmosets.

    PubMed

    Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito

    2017-09-01

    Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Non-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer.

    PubMed

    Kitamura, Tatsuya; Ohtani, Keisuke

    2015-01-01

    This paper presents a method of measuring the vibration patterns on facial surfaces by using a scanning laser Doppler vibrometer (LDV). The surfaces of the face, neck, and body vibrate during phonation and, according to Titze (2001), these vibrations occur when aerodynamic energy is efficiently converted into acoustic energy at the glottis. A vocalist's vibration velocity patterns may therefore indicate his or her phonatory status or singing skills. LDVs enable laser-based non-contact measurement of the vibration velocity and displacement of a certain point on a vibrating object, and scanning LDVs permit multipoint measurements. The benefits of scanning LDVs originate from the facts that they do not affect the vibrations of measured objects and that they can rapidly measure the vibration patterns across planes. A case study is presented herein to demonstrate the method of measuring vibration velocity patterns with a scanning LDV. The objective of the experiment was to measure the vibration velocity differences between the modal and falsetto registers while three professional soprano singers sang sustained vowels at four pitch frequencies. The results suggest that there is a possibility that pitch frequency are correlated with vibration velocity. However, further investigations are necessary to clarify the relationships between vibration velocity patterns and phonation status and singing skills.

  20. Non-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer

    PubMed Central

    Kitamura, Tatsuya; Ohtani, Keisuke

    2015-01-01

    This paper presents a method of measuring the vibration patterns on facial surfaces by using a scanning laser Doppler vibrometer (LDV). The surfaces of the face, neck, and body vibrate during phonation and, according to Titze (2001), these vibrations occur when aerodynamic energy is efficiently converted into acoustic energy at the glottis. A vocalist's vibration velocity patterns may therefore indicate his or her phonatory status or singing skills. LDVs enable laser-based non-contact measurement of the vibration velocity and displacement of a certain point on a vibrating object, and scanning LDVs permit multipoint measurements. The benefits of scanning LDVs originate from the facts that they do not affect the vibrations of measured objects and that they can rapidly measure the vibration patterns across planes. A case study is presented herein to demonstrate the method of measuring vibration velocity patterns with a scanning LDV. The objective of the experiment was to measure the vibration velocity differences between the modal and falsetto registers while three professional soprano singers sang sustained vowels at four pitch frequencies. The results suggest that there is a possibility that pitch frequency are correlated with vibration velocity. However, further investigations are necessary to clarify the relationships between vibration velocity patterns and phonation status and singing skills. PMID:26579054

  1. Increase of reliability of contact networks of electric transport, due to increase of strength of the joint unit of pipes of different diameters

    NASA Astrophysics Data System (ADS)

    Sabitov, L. S.; Kashapov, N. F.; Gilmanshin, I. R.; Gatiyatov, I. Z.; Kuznetsov, I. L.

    2017-09-01

    The feature of the stress state of the supports of the contact networks is the presence of a joint of pipes of different diameters, the ultimate state of which is determined, as a rule, the strength of the weld. The proposed unit allows to increase the reliability and strength of the connection and also exclude the presence of a weld bead on the outer surface of the pipe of smaller diameter in the place of its attachment to the upper end of the support ring.

  2. Patterns of Genetic Coding Variation in a Native American Population before and after European Contact.

    PubMed

    Lindo, John; Rogers, Mary; Mallott, Elizabeth K; Petzelt, Barbara; Mitchell, Joycelynn; Archer, David; Cybulski, Jerome S; Malhi, Ripan S; DeGiorgio, Michael

    2018-05-03

    The effects of European colonization on the genomes of Native Americans may have produced excesses of potentially deleterious features, mainly due to the severe reductions in population size and corresponding losses of genetic diversity. This assumption, however, neither considers actual genomic patterns that existed before colonization nor does it adequately capture the effects of admixture. In this study, we analyze the whole-exome sequences of modern and ancient individuals from a Northwest Coast First Nation, with a demographic history similar to other indigenous populations from the Americas. We show that in approximately ten generations from initial European contact, the modern individuals exhibit reduced levels of novel and low-frequency variants, a lower proportion of potentially deleterious alleles, and decreased heterozygosity when compared to their ancestors. This pattern can be explained by a dramatic population decline, resulting in the loss of potentially damaging low-frequency variants, and subsequent admixture. We also find evidence that the indigenous population was on a steady decline in effective population size for several thousand years before contact, which emphasizes regional demography over the common conception of a uniform expansion after entry into the Americas. This study examines the genomic consequences of colonialism on an indigenous group and describes the continuing role of gene flow among modern populations. Copyright © 2018 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  3. An equilibrium-point model for fast, single-joint movement: I. Emergence of strategy-dependent EMG patterns.

    PubMed

    Latash, M L; Gottlieb, G L

    1991-09-01

    We describe a model for the regulation of fast, single-joint movements, based on the equilibrium-point hypothesis. Limb movement follows constant rate shifts of independently regulated neuromuscular variables. The independently regulated variables are tentatively identified as thresholds of a length sensitive reflex for each of the participating muscles. We use the model to predict EMG patterns associated with changes in the conditions of movement execution, specifically, changes in movement times, velocities, amplitudes, and moments of limb inertia. The approach provides a theoretical neural framework for the dual-strategy hypothesis, which considers certain movements to be results of one of two basic, speed-sensitive or speed-insensitive strategies. This model is advanced as an alternative to pattern-imposing models based on explicit regulation of timing and amplitudes of signals that are explicitly manifest in the EMG patterns.

  4. Joint attention helps infants learn new words: event-related potential evidence.

    PubMed

    Hirotani, Masako; Stets, Manuela; Striano, Tricia; Friederici, Angela D

    2009-04-22

    This study investigated the role of joint attention in infants' word learning. Infants aged 18-21 months were taught new words in two social contexts, joint attention (eye contact, positive tone of voice) or non-joint attention (no eye contact, neutral tone of voice). Event-related potentials were measured as the infants saw objects either congruent or incongruent with the taught words. For both social contexts, an early negativity was observed for the congruent condition, reflecting a phonological-lexical priming effect between objects and the taught words. In addition, for the joint attention, the incongruent condition elicited a late, widely distributed negativity, attributed to semantic integration difficulties. Thus, social cues have an impact on how words are learned and represented in a child's mental lexicon.

  5. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    PubMed

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  6. Improvement and evaluation of thermal, electrical, sealing and mechanical contacts, and their interface materials

    NASA Astrophysics Data System (ADS)

    Luo, Xiangcheng

    Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic

  7. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.

  8. Strategy of arm movement control is determined by minimization of neural effort for joint coordination.

    PubMed

    Dounskaia, Natalia; Shimansky, Yury

    2016-06-01

    Optimality criteria underlying organization of arm movements are often validated by testing their ability to adequately predict hand trajectories. However, kinematic redundancy of the arm allows production of the same hand trajectory through different joint coordination patterns. We therefore consider movement optimality at the level of joint coordination patterns. A review of studies of multi-joint movement control suggests that a 'trailing' pattern of joint control is consistently observed during which a single ('leading') joint is rotated actively and interaction torque produced by this joint is the primary contributor to the motion of the other ('trailing') joints. A tendency to use the trailing pattern whenever the kinematic redundancy is sufficient and increased utilization of this pattern during skillful movements suggests optimality of the trailing pattern. The goal of this study is to determine the cost function minimization of which predicts the trailing pattern. We show that extensive experimental testing of many known cost functions cannot successfully explain optimality of the trailing pattern. We therefore propose a novel cost function that represents neural effort for joint coordination. That effort is quantified as the cost of neural information processing required for joint coordination. We show that a tendency to reduce this 'neurocomputational' cost predicts the trailing pattern and that the theoretically developed predictions fully agree with the experimental findings on control of multi-joint movements. Implications for future research of the suggested interpretation of the trailing joint control pattern and the theory of joint coordination underlying it are discussed.

  9. Subject-Specific Modeling of Muscle Force and Knee Contact in Total Knee Arthroplasty

    PubMed Central

    Navacchia, Alessandro; Rullkoetter, Paul J.; Schütz, Pascal; List, Renate B.; Fitzpatrick, Clare K.; Shelburne, Kevin B.

    2017-01-01

    Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal–external rotation, joint load, and tibial insert conformity. PMID:26792665

  10. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  11. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Train Operations at Track Classes 6 and Higher § 213.351... contraction due to temperature variations. When no-slip, joint-to-rail contact exists by design, the...

  12. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  13. Glenohumeral contact force during flat and topspin tennis forehand drives.

    PubMed

    Blache, Yoann; Creveaux, Thomas; Dumas, Raphaël; Chèze, Laurence; Rogowski, Isabelle

    2017-03-01

    The primary role of the shoulder joint in tennis forehand drive is at the expense of the loadings undergone by this joint. Nevertheless, few studies investigated glenohumeral (GH) contact forces during forehand drives. The aim of this study was to investigate GH compressive and shearing forces during the flat and topspin forehand drives in advanced tennis players. 3D kinematics of flat and topspin forehand drives of 11 advanced tennis players were recorded. The Delft Shoulder and Elbow musculoskeletal model was implemented to assess the magnitude and orientation of GH contact forces during the forehand drives. The results showed no differences in magnitude and orientation of GH contact forces between the flat and topspin forehand drives. The estimated maximal GH contact force during the forward swing phase was 3573 ± 1383 N, which was on average 1.25 times greater than during the follow-through phase, and 5.8 times greater than during the backswing phase. Regardless the phase of the forehand drive, GH contact forces pointed towards the anterior-superior part of the glenoid therefore standing for shearing forces. Knowledge of GH contact forces during real sport tasks performed at high velocity may improve the understanding of various sport-specific adaptations and causative factors for shoulder problems.

  14. The impact of contact on students' attitudes towards peers with disabilities.

    PubMed

    Schwab, Susanne

    2017-03-01

    This study aimed to understand the relationship between contact with peers with Special Educational Needs (SEN) and students' attitudes towards their peers with SEN, by examining the inter-group contact theory in regular and inclusive classes. A total of 463 students in 8th grade, with a mean age of 14.42 years, from 25 secondary school classes in Styria (Austria) completed a self-report questionnaire regarding their contact with peers with SEN and their attitudes towards peers with disabilities. Contact was indicated by nominations for joint activities and examined in inclusive and regular classes. The German short version of the Chedoke-McMaster Attitudes towards Children with Handicaps scale (CATCH; Schwab, 2015b; Rosenbaum et al., 1986) was used to measure students' attitudes towards peers with learning disabilities and emotional disorders. Students with SEN are less frequently nominated by their peers for joint activities, such as working together on a school project. Students from inclusive and regular classes did not differ in their attitudes towards peers with SEN. However, those students who nominated at least one peer with SEN for a joint activity had more positive attitudes towards peers with disabilities. Freely choosing contact with a peer with SEN was associated with more positive attitudes towards disability while simply attending the same class may have no effect or even a negative impact on students' attitudes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Posterior labral injury in contact athletes.

    PubMed

    Mair, S D; Zarzour, R H; Speer, K P

    1998-01-01

    Nine athletes (seven football offensive linemen, one defensive lineman, and one lacrosse player) were found at arthroscopy to have posterior labral detachment from the glenoid. In our series, this lesion is specific to contact athletes who engage their opponents with arms in front of the body. All patients had pain with bench pressing and while participating in their sport, diminishing their ability to play effectively. Conservative measures were ineffective in relieving their symptoms. Examination under anesthesia revealed symmetric glenohumeral translation bilaterally, without evidence of posterior instability. Treatment consisted of glenoid rim abradement and posterior labral repair with a bioabsorbable tack. All patients returned to complete at least one full season of contact sports and weightlifting without pain (minimum follow-up, > or = 2 years). Although many injuries leading to subluxation of the glenohumeral joint occur when an unanticipated force is applied, contact athletes ready their shoulder muscles in anticipation of impact with opponents. This leads to a compressive force at the glenohumeral joint. We hypothesize that, in combination with a posteriorly directed force at impact, the resultant vector is a shearing force to the posterior labrum and articular surface. Repeated exposure leads to posterior labral detachment without capsular injury. Posterior labral reattachment provides consistently good results, allowing the athlete to return to competition.

  16. Thrust Force Analysis of Tripod Constant Velocity Joint Using Multibody Model

    NASA Astrophysics Data System (ADS)

    Sugiura, Hideki; Matsunaga, Tsugiharu; Mizutani, Yoshiteru; Ando, Yosei; Kashiwagi, Isashi

    A tripod constant velocity joint is used in the driveshaft of front wheel drive vehicles. Thrust force generated by this joint causes lateral vibration in these vehicles. To analyze the thrust force, a detailed model is constructed based on a multibody dynamics approach. This model includes all principal parts of the joint defined as rigid bodies and all force elements of contact and friction acting among these parts. This model utilizes a new contact modeling method of needle roller bearings for more precise and faster computation. By comparing computational and experimental results, the appropriateness of this model is verified and the principal factors inducing the second and third rotating order components of the thrust force are clarified. This paper also describes the influence of skewed needle rollers on the thrust force and evaluates the contribution of friction forces at each contact region to the thrust force.

  17. Variable reluctance switch avoids contact corrosion and contact bounce

    NASA Technical Reports Server (NTRS)

    Watson, P. C.

    1967-01-01

    Variable reluctance switch avoids contact corrosion and bounce in a hostile environment. It consists of a wire-wound magnetic core and moveable bridge piece that alters the core flux pattern to produce an electrical output useful for switching control media.

  18. Joint dynamics of rear- and fore-foot unplanned sidestepping.

    PubMed

    Donnelly, Cyril J; Chinnasee, Chamnan; Weir, Gillian; Sasimontonkul, Siriporn; Alderson, Jacqueline

    2017-01-01

    Compare the lower-limb mechanics and anterior cruciate ligament (ACL) injury risk of athletes using a habitual rear-foot (RF) and fore-foot (FF) fall pattern during unplanned sidestepping (UnSS). Experimental cross-sectional. Nineteen elite female field hockey players attended one biomechanical motion capture testing session, which consisted of a random series of pre-planned and unplanned sidestepping sport tasks. Following data collection, participants were classified as possessing a habitual RF or FF fall pattern during UnSS. Hip, knee and ankle joint angles, moments, instantaneous powers and net joint work were calculated during weight acceptance. Between group differences were evaluated using independent sample t-tests (α=0.05). Athletes using a habitual RF fall pattern during UnSS absorbed significantly more work and power through their knee joint (p<0.001), which was coupled with significantly elevated externally applied peak non-sagittal plane peak ankle moments (p<0.05) as well as peak flexion and abduction knee moments (p<0.005). Athletes using a habitual FF fall pattern during UnSS absorbed more power through their ankle joint (p<0.001). A RF fall pattern during UnSS places a large mechanical demand on the knee joint, which is associated with elevated ACL injury risk. Conversely, a FF fall pattern placed a large mechanical demand on the ankle joint. Modifying an athlete's foot fall pattern during UnSS may be viable technique recommendation when returning from knee or ankle injury. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Leakproof Swaged Joints in Thin-Wall Tubing

    NASA Technical Reports Server (NTRS)

    Stuckenberg, F. H.; Crockett, L. K.; Snyder, W. E.

    1986-01-01

    Tubular inserts reinforce joints, reducing incidence of leaks. In new swaging technique, tubular inserts placed inside ends of both tubes to be joined. Made from thicker-wall tubing with outside diameter that matches inside diameter of thin tubing swaged, inserts support tube ends at joint. They ensure more uniform contact between swage fitting and tubing. New swaging technique developed for Al/Ti/V-alloy hydraulic supply lines.

  20. Movement and contact patterns of long-distance free-grazing ducks and avian influenza persistence in Vietnam.

    PubMed

    Meyer, Anne; Dinh, Tung Xuan; Nhu, Thu Van; Pham, Long Thanh; Newman, Scott; Nguyen, Thuy Thi Thanh; Pfeiffer, Dirk Udo; Vergne, Timothée

    2017-01-01

    Presence of ducks, and in particular of free-grazing ducks, has consistently been shown to be one of the most important risk factors for highly pathogenic avian influenza outbreaks which has compromised poultry production in South-East Asia since the early 2000s and continues to threaten public health, farmers' livelihood and food security. Although free-grazing duck production has been practised for decades in South-East Asia, there are few published studies describing this production system, which is suspected to play an important role in the maintenance of avian influenza viruses. This study aimed at describing quantitatively the long-distance free-grazing duck production system in South Vietnam, characterising the movement and contact patterns of the duck flocks, and identifying potential associations between farming practices, movement and contact patterns and the circulation of avian influenza viruses. We conducted interviews among stakeholders involved in the free-grazing duck production system (duck farmers, transporters and rice paddy owners) in combination with a virological cross-sectional survey in South Vietnam. Results show that both direct and indirect contacts between free-grazing duck flocks were frequent and diverse. The flocks were transported extensively across district and province boundaries, mainly by boat but also by truck or on foot. A third of the investigated flocks had a positive influenza A virology test, indicating current circulation of avian influenza viruses, but none were positive for H5 subtypes. The age and size of the flock as well as its location at the time of sampling were associated with the risk of influenza A circulation in the flocks. These findings should be considered when developing risk assessment models of influenza virus spread aimed at informing the development of improved biosecurity practices leading to enhanced animal health, sustainable animal production and reliable income for farmers.

  1. Movement and contact patterns of long-distance free-grazing ducks and avian influenza persistence in Vietnam

    PubMed Central

    Dinh, Tung Xuan; Nhu, Thu Van; Pham, Long Thanh; Newman, Scott; Nguyen, Thuy Thi Thanh; Pfeiffer, Dirk Udo; Vergne, Timothée

    2017-01-01

    Presence of ducks, and in particular of free-grazing ducks, has consistently been shown to be one of the most important risk factors for highly pathogenic avian influenza outbreaks which has compromised poultry production in South-East Asia since the early 2000s and continues to threaten public health, farmers’ livelihood and food security. Although free-grazing duck production has been practised for decades in South-East Asia, there are few published studies describing this production system, which is suspected to play an important role in the maintenance of avian influenza viruses. This study aimed at describing quantitatively the long-distance free-grazing duck production system in South Vietnam, characterising the movement and contact patterns of the duck flocks, and identifying potential associations between farming practices, movement and contact patterns and the circulation of avian influenza viruses. We conducted interviews among stakeholders involved in the free-grazing duck production system (duck farmers, transporters and rice paddy owners) in combination with a virological cross-sectional survey in South Vietnam. Results show that both direct and indirect contacts between free-grazing duck flocks were frequent and diverse. The flocks were transported extensively across district and province boundaries, mainly by boat but also by truck or on foot. A third of the investigated flocks had a positive influenza A virology test, indicating current circulation of avian influenza viruses, but none were positive for H5 subtypes. The age and size of the flock as well as its location at the time of sampling were associated with the risk of influenza A circulation in the flocks. These findings should be considered when developing risk assessment models of influenza virus spread aimed at informing the development of improved biosecurity practices leading to enhanced animal health, sustainable animal production and reliable income for farmers. PMID:28632789

  2. Application of the surface azimuthal electrical resistivity survey method to determine patterns of regional joint orientation in glacial tills

    USGS Publications Warehouse

    Carlson, D.

    2010-01-01

    Joints within unconsolidated material such as glacial till can be primary avenues for the flow of electrical charge, water, and contaminants. To facilitate the siting and design of remediation programs, a need exists to map anisotropic distribution of such pathways within glacial tills by determining the azimuth of the dominant joint set. The azimuthal survey method uses standard resistivity equipment with a Wenner array rotated about a fixed center point at selected degree intervals that yields an apparent resistivity ellipse. From this ellipse, joint set orientation can be determined. Azimuthal surveys were conducted at 21 sites in a 500-km2 (193 mi2) area around Milwaukee, Wisconsin, and more specifically, at sites having more than 30 m (98 ft) of glacial till (to minimize the influence of underlying bedrock joints). The 26 azimuthal surveys revealed a systematic pattern to the trend of the dominant joint set within the tills, which is approximately parallel to ice flow direction during till deposition. The average orientation of the joint set parallel with the ice flow direction is N77??E and N37??E for the Oak Creek and Ozaukee tills, respectively. The mean difference between average direct observation of joint set orientations and average azimuthal resistivity results is 8??, which is one fifth of the difference of ice flow direction between the Ozaukee and Oak Creek tills. The results of this study suggest that the surface azimuthal electrical resistivity survey method used for local in situ studies can be a useful noninvasive method for delineating joint sets within shallow geologic material for regional studies. Copyright ?? 2010 The American Association of Petroleum Geologists/Division of Environmental Geosciences. All rights reserved.

  3. Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    PubMed

    Karimi, Mohammad Taghi; Mohammadi, Ali; Ebrahimi, Mohammad Hossein; McGarry, Anthony

    2017-02-01

    The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influence of these factors on deformation of the femoral head. Two subjects with LCPD participated in this study. Subject motion and the forces applied on the affected leg were recorded using a motion analysis system (Qualsis TM ) and a Kistler force plate. OpenSim software was used to determine joint contact force of the hip joint whilst walking with and without a Scottish Rite orthosis. 3D Models of hip joints of both subjects were produced by Mimics software. The deformation of femoral bone was determined by Abaqus. Mean values of the force applied on the leg increased while walking with the orthosis. There was no difference between bone mineral density (BMD) of the femoral bone of normal and LCPD sides (p-value>0.05) and no difference between hip joint contact force of normal and LCPD sides. Hip joint containment appeared to decrease follow the use of the orthosis. It can be concluded that the deformation of femoral head in LCPD may not be due to change in BMD or applied load. Although the Scottish Rite orthosis is used mostly to increase hip joint containment, it appears to reduce hip joint contact area. It is recommended that a similar study is conducted using a higher number of subjects. Copyright © 2016 IPEM. All rights reserved.

  4. Rolling Contact Fatigue Workshop July 26-27, 2011

    DOT National Transportation Integrated Search

    2012-08-01

    In July 2011, the Transportation Technology Center, Inc., coordinated the joint Federal Railroad Association/Association of American Railroads Workshop on Rolling Contact Fatigue (RCF). The workshop was held at the Congress Plaza Hotel in Chicago, IL...

  5. MRI-based analysis of patellofemoral cartilage contact, thickness, and alignment in extension, and during moderate and deep flexion.

    PubMed

    Freedman, Benjamin R; Sheehan, Frances T; Lerner, Amy L

    2015-10-01

    Several factors are believed to contribute to patellofemoral joint function throughout knee flexion including patellofemoral (PF) kinematics, contact, and bone morphology. However, data evaluating the PF joint in this highly flexed state have been limited. Therefore, the purpose of this study was to evaluate patellofemoral contact and alignment in low (0°), moderate (60°), and deep (140°) knee flexion, and then correlate these parameters to each other, as well as to femoral morphology. Sagittal magnetic resonance images were acquired on 14 healthy female adult knees (RSRB approved) using a 1.5 T scanner with the knee in full extension, mid-flexion, and deep flexion. The patellofemoral cartilage contact area, lateral contact displacement (LCD), cartilage thickness, and lateral patellar displacement (LPD) throughout flexion were defined. Intra- and inter-rater repeatability measures were determined. Correlations between patellofemoral contact parameters, alignment, and sulcus morphology were calculated. Measurement repeatability ICCs ranged from 0.94 to 0.99. Patellofemoral cartilage contact area and thickness, LCD, and LPD were statistically different throughout all levels of flexion (p<0.001). The cartilage contact area was correlated to LPD, cartilage thickness, sulcus angle, and epicondylar width (r=0.47-0.72, p<0.05). This study provides a comprehensive analysis of the patellofemoral joint throughout its range of motion. This study agrees with past studies that investigated patellofemoral measures at a single flexion angle, and provides new insights into the relationship between patellofemoral contact and alignment at multiple flexion angles. The study provides a detailed analysis of the patellofemoral joint in vivo, and demonstrates the feasibility of using standard clinical magnetic resonance imaging scanners to image the knee joint in deep flexion. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Three-Dimensional Geometric Nonlinear Contact Stress Analysis of Riveted Joints

    NASA Technical Reports Server (NTRS)

    Shivakumar, Kunigal N.; Ramanujapuram, Vivek

    1998-01-01

    The problems associated with fatigue were brought into the forefront of research by the explosive decompression and structural failure of the Aloha Airlines Flight 243 in 1988. The structural failure of this airplane has been attributed to debonding and multiple cracking along the longitudinal lap splice riveted joint in the fuselage. This crash created what may be termed as a minor "Structural Integrity Revolution" in the commercial transport industry. Major steps have been taken by the manufacturers, operators and authorities to improve the structural airworthiness of the aging fleet of airplanes. Notwithstanding, this considerable effort there are still outstanding issues and concerns related to the formulation of Widespread Fatigue Damage which is believed to have been a contributing factor in the probable cause of the Aloha accident. The lesson from this accident was that Multiple-Site Damage (MSD) in "aging" aircraft can lead to extensive aircraft damage. A strong candidate in which MSD is highly probable to occur is the riveted lap joint.

  7. Design optimization of dual-axis driving mechanism for satellite antenna with two planar revolute clearance joints

    NASA Astrophysics Data System (ADS)

    Bai, Zheng Feng; Zhao, Ji Jun; Chen, Jun; Zhao, Yang

    2018-03-01

    In the dynamic analysis of satellite antenna dual-axis driving mechanism, it is usually assumed that the joints are ideal or perfect without clearances. However, in reality, clearances in joints are unavoidable due to assemblage, manufacturing errors and wear. When clearance is introduced to the mechanism, it will lead to poor dynamic performances and undesirable vibrations due to impact forces in clearance joint. In this paper, a design optimization method is presented to reduce the undesirable vibrations of satellite antenna considering clearance joints in dual-axis driving mechanism. The contact force model in clearance joint is established using a nonlinear spring-damper model and the friction effect is considered using a modified Coulomb friction model. Firstly, the effects of clearances on dynamic responses of satellite antenna are investigated. Then the optimization method for dynamic design of the dual-axis driving mechanism with clearance is presented. The objective of the optimization is to minimize the maximum absolute vibration peak of antenna acceleration by reducing the impact forces in clearance joint. The main consideration here is to optimize the contact parameters of the joint elements. The contact stiffness coefficient, damping coefficient and the dynamic friction coefficient for clearance joint elements are taken as the optimization variables. A Generalized Reduced Gradient (GRG) algorithm is used to solve this highly nonlinear optimization problem for dual-axis driving mechanism with clearance joints. The results show that the acceleration peaks of satellite antenna and contact forces in clearance joints are reduced obviously after design optimization, which contributes to a better performance of the satellite antenna. Also, the application and limitation of the proposed optimization method are discussed.

  8. Thigh-calf contact parameters for six high knee flexion postures: Onset, maximum angle, total force, contact area, and center of force.

    PubMed

    Kingston, David C; Acker, Stacey M

    2018-01-23

    In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A parametric shell analysis of the shuttle 51-L SRB AFT field joint

    NASA Technical Reports Server (NTRS)

    Davis, Randall C.; Bowman, Lynn M.; Hughes, Robert M., IV; Jackson, Brian J.

    1990-01-01

    Following the Shuttle 51-L accident, an investigation was conducted to determine the cause of the failure. Investigators at the Langley Research Center focused attention on the structural behavior of the field joints with O-ring seals in the steel solid rocket booster (SRB) cases. The shell-of-revolution computer program BOSOR4 was used to model the aft field joint of the solid rocket booster case. The shell model consisted of the SRB wall and joint geometry present during the Shuttle 51-L flight. A parametric study of the joint was performed on the geometry, including joint clearances, contact between the joint components, and on the loads, induced and applied. In addition combinations of geometry and loads were evaluated. The analytical results from the parametric study showed that contact between the joint components was a primary contributor to allowing hot gases to blow by the O-rings. Based upon understanding the original joint behavior, various proposed joint modifications are shown and analyzed in order to provide additional insight and information. Finally, experimental results from a hydro-static pressurization of a test rocket booster case to study joint motion are presented and verified analytically.

  10. Development of Mathematic Model of Cold Welding at Drawing-up the Flange Joint of Pneumohydraulic Systems

    NASA Astrophysics Data System (ADS)

    Boyko, Y. S.

    2002-01-01

    Provision of high airtightness of joints of pipe- lines of pneumohydraulic systems (PHS) operating under high pressure, is an important task for designing and operation of launch vehicles. In the process of assembly and tests of PHS of launch vehicles, it was found that detachable flange joints do not lose their airtightness after removal of fastening elements, even in conditions of standard loads. The task of this work is in studying a phenomenon connected with initiation of the observed effect of adhesion and also stresses in the zone of contact at drawing- up the flange detachable joints with a plastic gasket. Investigations have shown that density of the joint is kept due to cold welding, as the created conditions are helpful for that process. As a result of the investigations performed, we have developed a mathematic model which is based on application of the theory of metal bonds; that theory explains the essence of the effect observed. Basic factors which provide optimum mode of cold welding, are effort which can cause microplastic deformation and form maximum contact, and also quality of processing the material of the surfaces joined. Strength of all- metal joint depends on factual area of contact. So, surface processing quality defines a configuration of microbulges which come into contact not simultaneously, and their stressed state is different, and it influences the character of dependence of the contact area on loading. Results of calculations by the mathematic model are expressed by dependencies of factual area of contact and a single diameter of the contact spot on the load applied which compresses the materials with various physical properties, and on the surface processing quality. The mathematic model allows to explain the common character of the cold welding process in detachable flange joints with the plastic gasket, to determine the nature and the character of acting forces, to define kinetics and the mechanism of formation of cold welding of

  11. Joint mobilization acutely improves landing kinematics in chronic ankle instability.

    PubMed

    Delahunt, Eamonn; Cusack, Kim; Wilson, Laura; Doherty, Cailbhe

    2013-03-01

    The objective of this study is to examine the acute effect of ankle joint mobilizations akin to those performed in everyday clinical practice on sagittal plane ankle joint kinematics during a single-leg drop landing in participants with chronic ankle instability (CAI). Fifteen participants with self-reported CAI (defined as <24 on the Cumberland Ankle Instability Tool) performed three single-leg drop landings under two different conditions: 1) premobilization and, 2) immediately, postmobilization. The mobilizations performed included Mulligan talocrural joint dorsiflexion mobilization with movement, Mulligan inferior tibiofibular joint mobilization, and Maitland anteroposterior talocrural joint mobilization. Three CODA cx1 units (Charnwood Dynamics Ltd., Leicestershire, UK) were used to provide information on ankle joint sagittal plane angular displacement. The dependent variable under investigation was the angle of ankle joint plantarflexion at the point of initial contact during the drop landing. There was a statistically significant acute decrease in the angle of ankle joint plantarflexion from premobilization (34.89° ± 4.18°) to postmobilization (31.90° ± 5.89°), t(14) = 2.62, P < 0.05 (two-tailed). The mean decrease in the angle of ankle joint plantarflexion as a result of the ankle joint mobilization was 2.98° with a 95% confidence interval ranging from 0.54 to 5.43. The eta squared statistic (0.32) indicated a large effect size. These results indicate that mobilization acted to acutely reduce the angle of ankle joint plantarflexion at initial contact during a single-leg drop landing. Mobilization applied to participants with CAI has a mechanical effect on the ankle joint, thus facilitating a more favorable positioning of the ankle joint when landing from a jump.

  12. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

    PubMed

    Yoshida, H; Faust, A; Wilckens, J; Kitagawa, M; Fetto, J; Chao, Edmund Y-S

    2006-01-01

    Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.

  13. Atypical pattern of (meth)acrylate allergic contact dermatitis in dental professionals.

    PubMed

    Prasad Hunasehally, R Y; Hughes, T M; Stone, N M

    2012-09-01

    (Meth)acrylates in dental bonding agents are a common source of allergic contact dermatitis in dental professionals. The distribution of the contact dermatitis is commonly on finger tips, but is determined by individual habits as demonstrated by the two case reports in this article. Despite the site of contact dermatitis, the bonding agents are often not suspected as a source of contact allergy due to misconception regarding the protective effect of natural rubber latex gloves. With these case reports, we endeavour to emphasize the inadequacy of the latex gloves in protecting against the (meth)acrylate induced contact allergy and also list the measures a dental professional needs to incorporate in order to minimise the risks of sensitisation to (meth)acrylates.

  14. Biomechanical study of tarsometatarsal joint fusion using finite element analysis.

    PubMed

    Wang, Yan; Li, Zengyong; Zhang, Ming

    2014-11-01

    Complications of surgeries in foot and ankle bring patients with severe sufferings. Sufficient understanding of the internal biomechanical information such as stress distribution, contact pressure, and deformation is critical to estimate the effectiveness of surgical treatments and avoid complications. Foot and ankle is an intricate and synergetic system, and localized intervention may alter the functions to the adjacent components. The aim of this study was to estimate biomechanical effects of the TMT joint fusion using comprehensive finite element (FE) analysis. A foot and ankle model consists of 28 bones, 72 ligaments, and plantar fascia with soft tissues embracing all the segments. Kinematic information and ground reaction force during gait were obtained from motion analysis. Three gait instants namely the first peak, second peak and mid-stance were simulated in a normal foot and a foot with TMT joint fusion. It was found that contact pressure on plantar foot increased by 0.42%, 19% and 37%, respectively after TMT fusion compared with normal foot walking. Navico-cuneiform and fifth meta-cuboid joints sustained 27% and 40% increase in contact pressure at second peak, implying potential risk of joint problems such as arthritis. Von Mises stress in the second metatarsal bone increased by 22% at midstance, making it susceptible to stress fracture. This study provides biomechanical information for understanding the possible consequences of TMT joint fusion. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Long-term stress distribution patterns of the ankle joint in varus knee alignment assessed by computed tomography osteoabsorptiometry.

    PubMed

    Onodera, Tomohiro; Majima, Tokifumi; Iwasaki, Norimasa; Kamishima, Tamotsu; Kasahara, Yasuhiko; Minami, Akio

    2012-09-01

    The stress distribution of an ankle under various physiological conditions is important for long-term survival of total ankle arthroplasty. The aim of this study was to measure subchondral bone density across the distal tibial joint surface in patients with malalignment/instability of the lower limb. We evaluated subchondral bone density across the distal tibial joint in patients with malalignment/instability of the knee by computed tomography (CT) osteoabsorptiometry from ten ankles as controls and from 27 ankles with varus deformity/instability of the knee. The quantitative analysis focused on the location of the high-density area at the articular surface, to determine the resultant long-term stress on the ankle joint. The area of maximum density of subchondral bone was located in the medial part in all subjects. The pattern of maximum density in the anterolateral area showed stepwise increases with the development of varus deformity/instability of the knee. Our results should prove helpful for designing new prostheses and determining clinical indications for total ankle arthroplasty.

  16. Modelling the impact of correlations between condom use and sexual contact pattern on the dynamics of sexually transmitted infections.

    PubMed

    Yamamoto, Nao; Ejima, Keisuke; Nishiura, Hiroshi

    2018-05-31

    It is believed that sexually active people, i.e. people having multiple or concurrent sexual partners, are at a high risk of sexually transmitted infections (STI), but they are likely to be more aware of the risk and may exhibit greater fraction of the use of condom. The purpose of the present study is to examine the correlation between condom use and sexual contact pattern and clarify its impact on the transmission dynamics of STIs using a mathematical model. The definition of sexual contact pattern can be broad, but we focus on two specific aspects: (i) type of partnership (i.e. steady or casual partnership) and (ii) existence of concurrency (i.e. with single or multiple partners). Systematic review and meta-analysis of published studies are performed, analysing literature that epidemiologically examined the relationship between condom use and sexual contact pattern. Subsequently, we employ an epidemiological model and compute the reproduction number that accounts for with and without concurrency so that the corresponding coverage of condom use and its correlation with existence of concurrency can be explicitly investigated using the mathematical model. Combining the model with parameters estimated from the meta-analysis along with other assumed parameters, the impact of varying the proportion of population with multiple partners on the reproduction number is examined. Based on systematic review, we show that a greater number of people used condoms during sexual contact with casual partners than with steady partners. Furthermore, people with multiple partners use condoms more frequently than people with a single partner alone. Our mathematical model revealed a positive relationship between the effective reproduction number and the proportion of people with multiple partners. Nevertheless, the association was reversed to be negative by employing a slightly greater value of the relative risk of condom use for people with multiple partners than that empirically

  17. Water-contact patterns in relation to Schistosoma haematobium infection

    PubMed Central

    Dalton, P. R.; Pole, D.

    1978-01-01

    Water-contact observations were carried out on a population exposed to Schistosoma haematobium in a village situated on a man-made lake, Lake Volta, Ghana. The observations were made over a period of 12 months prior to the introduction of control measures. A multiple regression analysis was performed on the results of observations on 132 individuals, with egg output as the dependent variable and various types of water-contact activity, as well as age and sex, as independent variables. In the analysis, specific activities, notably water-contact for domestic purposes and activities associated with fishermen's canoes, were found to be significantly related to schistosomiasis. Age was less important than degree of exposure as a contributory factor to variations in infection rates: the reduced intensity of infection of S. haematobium in the older age groups could be mainly due to a lower level of exposure to the cercarial population. PMID:308406

  18. Redistribution of Mechanical Work at the Knee and Ankle Joints During Fast Running in Minimalist Shoes.

    PubMed

    Fuller, Joel T; Buckley, Jonathan D; Tsiros, Margarita D; Brown, Nicholas A T; Thewlis, Dominic

    2016-10-01

    Minimalist shoes have been suggested as a way to alter running biomechanics to improve running performance and reduce injuries. However, to date, researchers have only considered the effect of minimalist shoes at slow running speeds. To determine if runners change foot-strike pattern and alter the distribution of mechanical work at the knee and ankle joints when running at a fast speed in minimalist shoes compared with conventional running shoes. Crossover study. Research laboratory. Twenty-six trained runners (age = 30.0 ± 7.9 years [age range, 18-40 years], height = 1.79 ± 0.06 m, mass = 75.3 ± 8.2 kg, weekly training distance = 27 ± 15 km) who ran with a habitual rearfoot foot-strike pattern and had no experience running in minimalist shoes. Participants completed overground running trials at 18 km/h in minimalist and conventional shoes. Sagittal-plane kinematics and joint work at the knee and ankle joints were computed using 3-dimensional kinematic and ground reaction force data. Foot-strike pattern was classified as rearfoot, midfoot, or forefoot strike based on strike index and ankle angle at initial contact. We observed no difference in foot-strike classification between shoes (χ 2 1 = 2.29, P = .13). Ankle angle at initial contact was less (2.46° versus 7.43°; t 25 = 3.34, P = .003) and strike index was greater (35.97% versus 29.04%; t 25 = 2.38, P = .03) when running in minimalist shoes compared with conventional shoes. We observed greater negative (52.87 J versus 42.46 J; t 24 = 2.29, P = .03) and positive work (68.91 J versus 59.08 J; t 24 = 2.65, P = .01) at the ankle but less negative (59.01 J versus 67.02 J; t 24 = 2.25, P = .03) and positive work (40.37 J versus 47.09 J; t 24 = 2.11, P = .046) at the knee with minimalist shoes compared with conventional shoes. Running in minimalist shoes at a fast speed caused a redistribution of work from the knee to the ankle joint. This finding suggests that runners changing from conventional to minimalist

  19. Redistribution of Mechanical Work at the Knee and Ankle Joints During Fast Running in Minimalist Shoes

    PubMed Central

    Fuller, Joel T.; Buckley, Jonathan D.; Tsiros, Margarita D.; Brown, Nicholas A. T.; Thewlis, Dominic

    2016-01-01

    Context: Minimalist shoes have been suggested as a way to alter running biomechanics to improve running performance and reduce injuries. However, to date, researchers have only considered the effect of minimalist shoes at slow running speeds. Objective: To determine if runners change foot-strike pattern and alter the distribution of mechanical work at the knee and ankle joints when running at a fast speed in minimalist shoes compared with conventional running shoes. Design: Crossover study. Setting: Research laboratory. Patients or Other Participants: Twenty-six trained runners (age = 30.0 ± 7.9 years [age range, 18−40 years], height = 1.79 ± 0.06 m, mass = 75.3 ± 8.2 kg, weekly training distance = 27 ± 15 km) who ran with a habitual rearfoot foot-strike pattern and had no experience running in minimalist shoes. Intervention(s): Participants completed overground running trials at 18 km/h in minimalist and conventional shoes. Main Outcome Measure(s): Sagittal-plane kinematics and joint work at the knee and ankle joints were computed using 3-dimensional kinematic and ground reaction force data. Foot-strike pattern was classified as rearfoot, midfoot, or forefoot strike based on strike index and ankle angle at initial contact. Results: We observed no difference in foot-strike classification between shoes (χ21 = 2.29, P = .13). Ankle angle at initial contact was less (2.46° versus 7.43°; t25 = 3.34, P = .003) and strike index was greater (35.97% versus 29.04%; t25 = 2.38, P = .03) when running in minimalist shoes compared with conventional shoes. We observed greater negative (52.87 J versus 42.46 J; t24 = 2.29, P = .03) and positive work (68.91 J versus 59.08 J; t24 = 2.65, P = .01) at the ankle but less negative (59.01 J versus 67.02 J; t24 = 2.25, P = .03) and positive work (40.37 J versus 47.09 J; t24 = 2.11, P = .046) at the knee with minimalist shoes compared with conventional shoes. Conclusions: Running in minimalist shoes at a fast speed caused a

  20. Physical validation of a patient-specific contact finite element model of the ankle.

    PubMed

    Anderson, Donald D; Goldsworthy, Jane K; Li, Wendy; James Rudert, M; Tochigi, Yuki; Brown, Thomas D

    2007-01-01

    A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those from an intact versus those with residual intra-articular fracture incongruity).

  1. The Movement- and Load-Dependent Differences in the EMG Patterns of the Human Arm Muscles during Two-Joint Movements (A Preliminary Study)

    PubMed Central

    Tomiak, Tomasz; Abramovych, Tetiana I.; Gorkovenko, Andriy V.; Vereshchaka, Inna V.; Mishchenko, Viktor S.; Dornowski, Marcin; Kostyukov, Alexander I.

    2016-01-01

    Slow circular movements of the hand with a fixed wrist joint that were produced in a horizontal plane under visual guidance during conditions of action of the elastic load directed tangentially to the movement trajectory were studied. The positional dependencies of the averaged surface EMGs in the muscles of the elbow and shoulder joints were compared for four possible combinations in the directions of load and movements. The EMG intensities were largely correlated with the waves of the force moment computed for a corresponding joint in the framework of a simple geometrical model of the system: arm - experimental setup. At the same time, in some cases the averaged EMGs exit from the segments of the trajectory restricted by the force moment singular points (FMSPs), in which the moments exhibited altered signs. The EMG activities display clear differences for the eccentric and concentric zones of contraction that are separated by the joint angle singular points (JASPs), which present extreme at the joint angle traces. We assumed that the modeled patterns of FMSPs and JASPs may be applied for an analysis of the synergic interaction between the motor commands arriving at different muscles in arbitrary two-joint movements. PMID:27375496

  2. Sensitivity of medial and lateral knee contact force predictions to frontal plane alignment and contact locations.

    PubMed

    Saliba, Christopher M; Brandon, Scott C E; Deluzio, Kevin J

    2017-05-24

    Musculoskeletal models are increasingly used to estimate medial and lateral knee contact forces, which are difficult to measure in vivo. The sensitivity of contact force predictions to modeling parameters is important to the interpretation and implication of results generated by the model. The purpose of this study was to quantify the sensitivity of knee contact force predictions to simultaneous errors in frontal plane knee alignment and contact locations under different dynamic conditions. We scaled a generic musculoskeletal model for N=23 subjects' stature and radiographic knee alignment, then perturbed frontal plane alignment and mediolateral contact locations within experimentally-possible ranges of 10° to -10° and 10 to -10mm, respectively. The sensitivity of first peak, second peak, and mean medial and lateral knee contact forces to knee adduction angle and contact locations was modeled using linear regression. Medial loads increased, and lateral loads decreased, by between 3% and 6% bodyweight for each degree of varus perturbation. Shifting the medial contact point medially increased medial loads and decreased lateral loads by between 1% and 4% bodyweight per millimeter. This study demonstrates that realistic measurement errors of 5mm (contact distance) or 5° (frontal plane alignment) could result in a combined 50% BW error in subject specific contact force estimates. We also show that model sensitivity varies between subjects as a result of differences in gait dynamics. These results demonstrate that predicted knee joint contact forces should be considered as a range of possible values determined by model uncertainty. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Biomechanical analysis comparing natural and alloplastic temporomandibular joint replacement using a finite element model.

    PubMed

    Mesnard, Michel; Ramos, Antonio; Ballu, Alex; Morlier, Julien; Cid, M; Simoes, J A

    2011-04-01

    Prosthetic materials and bone present quite different mechanical properties. Consequently, mandible reconstruction with metallic materials (or a mandible condyle implant) modifies the physiologic behavior of the mandible (stress, strain patterns, and condyle displacements). The changing of bone strain distribution results in an adaptation of the temporomandibular joint, including articular contacts. Using a validated finite element model, the natural mandible strains and condyle displacements were evaluated. Modifications of strains and displacements were then assessed for 2 different temporomandibular joint implants. Because materials and geometry play important key roles, mechanical properties of cortical bone were taken into account in models used in finite element analysis. The finite element model allowed verification of the worst loading configuration of the mandibular condyle. Replacing the natural condyle by 1 of the 2 tested implants, the results also show the importance of the implant geometry concerning biomechanical mandibular behavior. The implant geometry and stiffness influenced mainly strain distribution. The different forces applied to the mandible by the elevator muscles, teeth, and joint loads indicate that the finite element model is a relevant tool to optimize implant geometry or, in a subsequent study, to choose a more suitable distribution of the screws. Bone screws (number and position) have a significant influence on mandibular behavior and on implant stress pattern. Stress concentration and implant fracture must be avoided. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Expecting ankle tilts and wearing an ankle brace influence joint control in an imitated ankle sprain mechanism during walking.

    PubMed

    Gehring, Dominic; Wissler, Sabrina; Lohrer, Heinz; Nauck, Tanja; Gollhofer, Albert

    2014-03-01

    A thorough understanding of the functional aspects of ankle joint control is essential to developing effective injury prevention. It is of special interest to understand how neuromuscular control mechanisms and mechanical constraints stabilize the ankle joint. Therefore, the aim of the present study was to determine how expecting ankle tilts and the application of an ankle brace influence ankle joint control when imitating the ankle sprain mechanism during walking. Ankle kinematics and muscle activity were assessed in 17 healthy men. During gait rapid perturbations were applied using a trapdoor (tilting with 24° inversion and 15° plantarflexion). The subjects either knew that a perturbation would definitely occur (expected tilts) or there was only the possibility that a perturbation would occur (potential tilts). Both conditions were conducted with and without a semi-rigid ankle brace. Expecting perturbations led to an increased ankle eversion at foot contact, which was mediated by an altered muscle preactivation pattern. Moreover, the maximal inversion angle (-7%) and velocity (-4%), as well as the reactive muscle response were significantly reduced when the perturbation was expected. While wearing an ankle brace did not influence muscle preactivation nor the ankle kinematics before ground contact, it significantly reduced the maximal ankle inversion angle (-14%) and velocity (-11%) as well as reactive neuromuscular responses. The present findings reveal that expecting ankle inversion modifies neuromuscular joint control prior to landing. Although such motor control strategies are weaker in their magnitude compared with braces, they seem to assist ankle joint stabilization in a close-to-injury situation. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Lumbopelvic muscle activation patterns in three stances under graded loading conditions: Proposing a tensegrity model for load transfer through the sacroiliac joints.

    PubMed

    Pardehshenas, Hamed; Maroufi, Nader; Sanjari, Mohammad Ali; Parnianpour, Mohamad; Levin, Stephen M

    2014-10-01

    According to the conventional arch model of the pelvis, stability of the sacroiliac joints may require a predominance of form and force closure mechanisms: the greater the vertical shear force at the sacroiliac joints, the greater the reliance on self-bracing by horizontally or obliquely oriented muscles (such as the internal oblique). But what happens to the arch model when a person stands on one leg? In such cases, the pelvis no longer has imposts, leaving both the arch, and the arch model theory, without support. Do lumbopelvic muscle activation patterns in one-legged stances under load suggest compatibility with a different model? This study compares lumbopelvic muscle activation patterns in two-legged and one-legged stances in response to four levels of graded trunk loading in order to further our understanding the stabilization of the sacroiliac joints. Thirty male subjects experienced four levels of trunk loading (0%, 5%, 10% and 15% of body weight) by holding a bucket at one side, at three conditions: 1) two-legged standing with the bucket in the dominant hand, 2) ipsilateral loading: one-legged standing with the bucket in the dominant hand while using the same-side leg, and 3) contralateral loading: one-legged standing using the same leg used in condition 2, but with the bucket in the non-dominant hand. During these tasks, EMG signals from eight lumbopelvic muscles were collected. ANOVA with repeated design was performed on normalized EMG's to test the main effect of load and condition, and interaction effects of load by condition. Latissimus dorsi and erector spinae muscles showed an antagonistic pattern of activity toward the direction of load which may suggest these muscles as lateral trunk stabilizers. Internal oblique muscles showed a co-activation pattern with increasing task demand, which may function to increase lumbopelvic stability (P < 0.05). No unilateral pattern of the internal obliques was observed during all trials. Our results suggest that

  6. Effect of the walking speed to the lower limb joint angular displacements, joint moments and ground reaction forces during walking in water.

    PubMed

    Miyoshi, Tasuku; Shirota, Takashi; Yamamoto, Shin-ichiro; Nakazawa, Kimitaka; Akai, Masami

    2004-06-17

    The purpose of this study was to compare the changes in ground reaction forces (GRF), joint angular displacements (JAD), joint moments (JM) and electromyographic (EMG) activities that occur during walking at various speeds in water and on land. Fifteen healthy adults participated in this study. In the water experiments, the water depth was adjusted so that body weight was reduced by 80%. A video-motion analysis system and waterproof force platform was used to obtain kinematics and kinetics data and to calculate the JMs. Results revealed that (1) the anterior-posterior GRF patterns differed between walking in water and walking on land, whereas the medio-lateral GRF patterns were similar, (2) the JAD patterns of the hip and ankle were similar between water- and land-walking, whereas the range of motion at the knee joint was lower in water than on land, (3) the JMs in all three joints were lower in water than on land throughout the stance phase, and (4) the hip joint extension moment and hip extensor muscle EMG activity were increased as walking speed increase during walking in water. Rehabilitative water-walking exercise could be designed to incorporate large-muscle activities, especially of the lower-limb extensor muscles, through full joint range of motion and minimization of joint moments.

  7. Subject-specific modeling of muscle force and knee contact in total knee arthroplasty.

    PubMed

    Navacchia, Alessandro; Rullkoetter, Paul J; Schütz, Pascal; List, Renate B; Fitzpatrick, Clare K; Shelburne, Kevin B

    2016-09-01

    Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal-external rotation, joint load, and tibial insert conformity. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1576-1587, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Short-term efficacy of sacroiliac joint corticosteroid injection based on arthrographic contrast patterns.

    PubMed

    Scholten, Paul M; Patel, Shounuck I; Christos, Paul J; Singh, Jaspal R

    2015-04-01

    To determine the relationship between sacroiliac joint (SIJ) contrast dispersal patterns during SIJ corticosteroid injection and pain relief at 2 and 8 weeks after the procedure. The association between the number of positive provocative SIJ physical examination maneuvers (minimum of one in all patients undergoing SIJ injection) and the patient's response to the intervention was also assessed. Retrospective chart review. Academic outpatient musculoskeletal practice. Fifty-four subjects who underwent therapeutic SIJ corticosteroid injection were screened for inclusion; 49 subjects were included in the final analysis. A retrospective review of electronic medical records identified patients who underwent SIJ corticosteroid injection. Fluoroscopic contrast flow patterns were categorized as type I (intra-articular injection with cephalad extension within the SIJ) or type II (intra-articular injection with poor cephalad extension). Self-reported numeric pain rating scale (NPRS) values at the time of injection and 2 and 8 weeks after the procedure were recorded. The number of positive provocative SIJ physical examination maneuvers at the time of the initial evaluation was also recorded. The primary outcome measure was the effect of contrast patterns (type I or type II) on change in NPRS values at 2 weeks and 8 weeks after the injection. The secondary outcome measure was the association between the number of positive provocative SIJ physical examination maneuvers and decrease in the level of pain after the procedure. At 2 weeks after the procedure, type I subjects demonstrated a significantly lower mean NPRS value compared with type II subjects (2.8 ± 1.4 versus 3.8 ± 1.6, respectively, P = .02). No statistically significant difference was observed at 8 weeks after the procedure. NPRS values were significantly reduced both at 2 weeks and 8 weeks, compared with baseline, in both subjects identified as having type I flow and those with type II flow (P < .0001 for all

  9. Modulation of the relationship between external knee adduction moments and medial joint contact forces across subjects and activities.

    PubMed

    Trepczynski, Adam; Kutzner, Ines; Bergmann, Georg; Taylor, William R; Heller, Markus O

    2014-05-01

    The external knee adduction moment (EAM) is often considered a surrogate measure of the distribution of loads across the tibiofemoral joint during walking. This study was undertaken to quantify the relationship between the EAM and directly measured medial tibiofemoral contact forces (Fmed ) in a sample of subjects across a spectrum of activities. The EAM for 9 patients who underwent total knee replacement was calculated using inverse dynamics analysis, while telemetric implants provided Fmed for multiple repetitions of 10 activities, including walking, stair negotiation, sit-to-stand activities, and squatting. The effects of the factors "subject" and "activity" on the relationships between Fmed and EAM were quantified using mixed-effects regression analyses in terms of the root mean square error (RMSE) and the slope of the regression. Across subjects and activities a good correlation between peak EAM and Fmed values was observed, with an overall R(2) value of 0.88. However, the slope of the linear regressions varied between subjects by up to a factor of 2. At peak EAM and Fmed , the RMSE of the regression across all subjects was 35% body weight (%BW), while the maximum error was 127 %BW. The relationship between EAM and Fmed is generally good but varies considerably across subjects and activities. These findings emphasize the limitation of relying solely on the EAM to infer medial joint loading when excessive directed cocontraction of muscles exists and call for further investigations into the soft tissue-related mechanisms that modulate the internal forces at the knee. Copyright © 2014 by the American College of Rheumatology.

  10. Knee Contact Force Asymmetries in Patients Who Failed Return-to-Sport Readiness Criteria 6 Months After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Gardinier, Emily S.; Di Stasi, Stephanie; Manal, Kurt; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background After anterior cruciate ligament (ACL) injury, contact forces are decreased in the injured knee when compared with the uninjured knee. The persistence of contact force asymmetries after ACL reconstruction may increase the risk of reinjury and may play an important role in the development of knee osteoarthritis in these patients. Functional performance may also be useful in identifying patients who demonstrate potentially harmful joint contact force asymmetries after ACL reconstruction. Hypothesis Knee joint contact force asymmetries would be present during gait after ACL reconstruction, and performance on a specific set of validated return-to-sport (RTS) readiness criteria would discriminate between those who demonstrated contact force asymmetries and those who did not. Study Design Descriptive laboratory study. Methods A total of 29 patients with ACL ruptures participated in gait analysis and RTS readiness testing 6 months after reconstruction. Muscle and joint contact forces were estimated using an electromyography (EMG)–driven musculoskeletal model of the knee. The magnitude of typical limb asymmetry in uninjured controls was used to define limits of meaningful limb asymmetry in patients after ACL reconstruction. The RTS testing included isometric quadriceps strength testing, 4 unilateral hop tests, and 2 self-report questionnaires. Paired t tests were used to assess limb symmetry for peak medial and tibiofemoral contact forces in all patients, and a mixed-design analysis of variance was used to analyze the effect of passing or failing RTS testing on contact force asymmetry. Results Among all patients, neither statistically significant nor meaningful contact force asymmetries were identified. However, patients who failed RTS testing exhibited meaningful contact force asymmetries, with tibiofemoral contact force being significantly lower for the involved knee. Conversely, patients who passed RTS testing exhibited neither significant nor meaningful

  11. The effect of the geometry and material properties of a carbon joint produced by electron beam induced deposition on the electrical resistance of a multiwalled carbon nanotube-to-metal contact interface

    NASA Astrophysics Data System (ADS)

    Rykaczewski, Konrad; Henry, Matthew R.; Kim, Song-Kil; Fedorov, Andrei G.; Kulkarni, Dhaval; Singamaneni, Srikanth; Tsukruk, Vladimir V.

    2010-01-01

    Multiwall carbon nanotubes (MWNTs) are promising candidates for yielding next generation electrical and electronic devices such as interconnects and tips for conductive force microscopy. One of the main challenges in MWNT implementation in such devices is the high contact resistance of the MWNT-metal electrode interface. Electron beam induced deposition (EBID) of an amorphous carbon interface has previously been demonstrated to simultaneously lower the electrical contact resistance and improve the mechanical characteristics of the MWNT-electrode connection. In this work, we investigate the influence of process parameters, such as the electron beam energy, current, geometry, and deposition time, on the EBID-made carbon joint geometry and electrical contact resistance. The influence of the composition of the deposited material on its resistivity is also investigated. The relative importance of each component of the contact resistance and the limiting factor of the overall electrical resistance of a MWNT-based interconnect is determined through a combination of a model analysis and comprehensive experiments.

  12. Cell-cell contact area affects Notch signaling and Notch-dependent patterning

    PubMed Central

    Shaya, Oren; Binshtok, Udi; Hersch, Micha; Rivkin, Dmitri; Weinreb, Sheila; Amir-Zilberstein, Liat; Khamaisi, Bassma; Oppenheim, Olya; Desai, Ravi A.; Goodyear, Richard J.; Richardson, Guy P.; Chen, Christopher S.; Sprinzak, David

    2017-01-01

    Summary During development, cells undergo dramatic changes in their morphology. By affecting contact geometry, these morphological changes could influence cellular communication. However, it has remained unclear whether and how signaling depends on contact geometry. This question is particularly relevant for Notch signaling, which coordinates neighboring cell fates through direct cell-cell signaling. Using micropatterning with a receptor trans-endocytosis assay, we show that signaling between pairs of cells correlates with their contact area. This relationship extends across contact diameters ranging from microns to tens of microns. Mathematical modeling predicts that dependence of signaling on contact area can bias cellular differentiation in Notch-mediated lateral inhibition processes, such that smaller cells are more likely to differentiate into signal-producing cells. Consistent with this prediction, analysis of developing chick inner ear revealed that ligand-producing hair cell precursors have smaller apical footprints than non-hair cells. Together, these results highlight the influence of cell morphology on fate determination processes. PMID:28292428

  13. Cell-Cell Contact Area Affects Notch Signaling and Notch-Dependent Patterning.

    PubMed

    Shaya, Oren; Binshtok, Udi; Hersch, Micha; Rivkin, Dmitri; Weinreb, Sheila; Amir-Zilberstein, Liat; Khamaisi, Bassma; Oppenheim, Olya; Desai, Ravi A; Goodyear, Richard J; Richardson, Guy P; Chen, Christopher S; Sprinzak, David

    2017-03-13

    During development, cells undergo dramatic changes in their morphology. By affecting contact geometry, these morphological changes could influence cellular communication. However, it has remained unclear whether and how signaling depends on contact geometry. This question is particularly relevant for Notch signaling, which coordinates neighboring cell fates through direct cell-cell signaling. Using micropatterning with a receptor trans-endocytosis assay, we show that signaling between pairs of cells correlates with their contact area. This relationship extends across contact diameters ranging from micrometers to tens of micrometers. Mathematical modeling predicts that dependence of signaling on contact area can bias cellular differentiation in Notch-mediated lateral inhibition processes, such that smaller cells are more likely to differentiate into signal-producing cells. Consistent with this prediction, analysis of developing chick inner ear revealed that ligand-producing hair cell precursors have smaller apical footprints than non-hair cells. Together, these results highlight the influence of cell morphology on fate determination processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Spatiotemporal Patterns of Contact Across the Rat Vibrissal Array During Exploratory Behavior

    PubMed Central

    Hobbs, Jennifer A.; Towal, R. Blythe; Hartmann, Mitra J. Z.

    2016-01-01

    The rat vibrissal system is an important model for the study of somatosensation, but the small size and rapid speed of the vibrissae have precluded measuring precise vibrissal-object contact sequences during behavior. We used a laser light sheet to quantify, with 1 ms resolution, the spatiotemporal structure of whisker-surface contact as five naïve rats freely explored a flat, vertical glass wall. Consistent with previous work, we show that the whisk cycle cannot be uniquely defined because different whiskers often move asynchronously, but that quasi-periodic (~8 Hz) variations in head velocity represent a distinct temporal feature on which to lock analysis. Around times of minimum head velocity, whiskers protract to make contact with the surface, and then sustain contact with the surface for extended durations (~25–60 ms) before detaching. This behavior results in discrete temporal windows in which large numbers of whiskers are in contact with the surface. These “sustained collective contact intervals” (SCCIs) were observed on 100% of whisks for all five rats. The overall spatiotemporal structure of the SCCIs can be qualitatively predicted based on information about head pose and the average whisk cycle. In contrast, precise sequences of whisker-surface contact depend on detailed head and whisker kinematics. Sequences of vibrissal contact were highly variable, equally likely to propagate in all directions across the array. Somewhat more structure was found when sequences of contacts were examined on a row-wise basis. In striking contrast to the high variability associated with contact sequences, a consistent feature of each SCCI was that the contact locations of the whiskers on the glass converged and moved more slowly on the sheet. Together, these findings lead us to propose that the rat uses a strategy of “windowed sampling” to extract an object's spatial features: specifically, the rat spatially integrates quasi-static mechanical signals across

  15. Patterned Liquid Metal Contacts for Printed Carbon Nanotube Transistors.

    PubMed

    Andrews, Joseph B; Mondal, Kunal; Neumann, Taylor V; Cardenas, Jorge A; Wang, Justin; Parekh, Dishit P; Lin, Yiliang; Ballentine, Peter; Dickey, Michael D; Franklin, Aaron D

    2018-05-14

    Flexible and stretchable electronics are poised to enable many applications that cannot be realized with traditional, rigid devices. One of the most promising options for low-cost stretchable transistors are printed carbon nanotubes (CNTs). However, a major limiting factor in stretchable CNT devices is the lack of a stable and versatile contact material that forms both the interconnects and contact electrodes. In this work, we introduce the use of eutectic gallium-indium (EGaIn) liquid metal for electrical contacts to printed CNT channels. We analyze thin-film transistors (TFTs) fabricated using two different liquid metal deposition techniques-vacuum-filling polydimethylsiloxane (PDMS) microchannel structures and direct-writing liquid metals on the CNTs. The highest performing CNT-TFT was realized using vacuum-filled microchannel deposition with an in situ annealing temperature of 150 °C. This device exhibited an on/off ratio of more than 10 4 and on-currents as high as 150 μA/mm-metrics that are on par with other printed CNT-TFTs. Additionally, we observed that at room temperature the contact resistances of the vacuum-filled microchannel structures were 50% lower than those of the direct-write structures, likely due to the poor adhesion between the materials observed during the direct-writing process. The insights gained in this study show that stretchable electronics can be realized using low-cost and solely solution processing techniques. Furthermore, we demonstrate methods that can be used to electrically characterize semiconducting materials as transistors without requiring elevated temperatures or cleanroom processes.

  16. The effects of the sagittal plane malpositioning of the patella and concomitant quadriceps hypotrophy on the patellofemoral joint: a finite element analysis.

    PubMed

    Aksahin, Ertugrul; Kocadal, Onur; Aktekin, Cem N; Kaya, Defne; Pepe, Murad; Yılmaz, Serdar; Yuksel, H Yalcin; Bicimoglu, Ali

    2016-03-01

    Anterior knee pain is a common symptom after intramedullary nailing in tibia shaft fracture. Moreover, patellofemoral malalignment is also known to be a major reason for anterior knee pain. Patellofemoral malalignment predisposes to increased loading in patellar cartilage. In the previous study, we have demonstrated the quadriceps atrophy and patellofemoral malalignment after intramedullary nailing due to tibia shaft fracture. In this study, our aim was to clarify the effects of quadriceps atrophy and patellofemoral malalignment with the pathologic loading on the joint cartilage. Mesh models of patellofemoral joint were constructed with CT images and integrated with soft tissue components such as menisci and ligaments. Physiological and sagittal tilt models during extension and flexion at 15°, 30° and 60° were created generating eight models. All the models were applied with 137 N force to present the effects of normal loading and 115.7 N force for the simulation of quadriceps atrophy. Different degrees of loading were applied to evaluate the joint contact area and pressure value with the finite element analysis. There was increased patellofemoral contact area in patellar tilt models with respect to normal models. The similar loading patterns were diagnosed in all models at 0° and 15° knee flexion when 137 N force was applied. Higher loading values were obtained at 30° and 60° knee flexions in sagittal tilt models. Furthermore, in the sagittal tilt models, in which the quadriceps atrophy was simulated, the loadings at 30° and 60° knee flexion were higher than in the physiological ones. Sagittal malalignment of the patellofemoral joint is a new concept that results in different loading patterns in the patellofemoral joint biomechanics. This malalignment in sagittal plane leads to increased loading values on the patellofemoral joint at 30° and 60° of the knee flexions. This new concept should be kept in mind during the course of diagnosis and treatment

  17. Patterns of contact within the New Zealand poultry industry.

    PubMed

    Lockhart, C Y; Stevenson, M A; Rawdon, T G; Gerber, N; French, N P

    2010-07-01

    Members of the Poultry Industry Association and the Egg Producers Federation of New Zealand (n=420) were sent a questionnaire asking them to describe the type and frequency of on- and off-enterprise movements relating to feed, live birds and hatching eggs, table eggs and poultry product, and manure and waste litter. Social network analyses were used to describe patterns of contact among poultry enterprises and their associates for these four movement types. The response rate to the survey was 58% (244 out of 420). Network structures for enterprise-to-enterprise movements of feed, live birds and hatching eggs, and table egg and poultry product were characterised by 'hub and spoke' type structures with small-world characteristics. Small worlds were created by network hubs (e.g. feed suppliers and hatcheries) providing goods and services to larger numbers of client farms. In addition to hubs acting as the predominant source of material moving onto farms we identified enterprises acting as bridges between identified small worlds. The presence of these bridges is a concern, since their presence has the potential to facilitate the spread of hazards (e.g. feed contaminants, infectious agents carried within feed) more readily throughout the population. An ability to predict enterprises with these network characteristics on the basis of factors such as shed capacity, enterprise type, geographic location would be useful for developing risk-based approaches to disease prevention, surveillance, detection, response and control activities. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Impact of Nonlinearity of The Contact Layer Between Elements Joined in a Multi-Bolted System on Its Preload

    NASA Astrophysics Data System (ADS)

    Grzejda, R.

    2017-12-01

    The paper deals with modelling and calculations of asymmetrical multi-bolted joints at the assembly stage. The physical model of the joint is based on a system composed of four subsystems, which are: a couple of joined elements, a contact layer between the elements, and a set of bolts. The contact layer is assumed as the Winkler model, which can be treated as a nonlinear or linear model. In contrast, the set of bolts are modelled using simplified beam models, known as spider bolt models. The theorem according to which nonlinearity of the contact layer has a negligible impact on the final preload of the joint in the case of its sequential tightening has been verified. Results of sample calculations for the selected multi-bolted system, in the form of diagrams of preloads in the bolts as well as normal contact pressure between the joined elements during the assembly process and at its end, are presented.

  19. Method of forming contacts for a back-contact solar cell

    DOEpatents

    Manning, Jane

    2013-07-23

    Methods of forming contacts for back-contact solar cells are described. In one embodiment, a method includes forming a thin dielectric layer on a substrate, forming a polysilicon layer on the thin dielectric layer, forming and patterning a solid-state p-type dopant source on the polysilicon layer, forming an n-type dopant source layer over exposed regions of the polysilicon layer and over a plurality of regions of the solid-state p-type dopant source, and heating the substrate to provide a plurality of n-type doped polysilicon regions among a plurality of p-type doped polysilicon regions.

  20. Female elk contacts are neither frequency nor density dependent

    USGS Publications Warehouse

    Cross, Paul C.; Creech, Tyler G.; Ebinger, Michael R.; Manlove, Kezia R.; Irvine, Kathryn M.; Henningsen, John C.; Rogerson, Jared D.; Scurlock, Brandon M.; Creely, Scott

    2013-01-01

    Identifying drivers of contact rates among individuals is critical to understanding disease dynamics and implementing targeted control measures. We studied the interaction patterns of 149 female elk (Cervus canadensis) distributed across five different regions of western Wyoming over three years, defining a contact as an approach within one body length (∼2 m). Using hierarchical models that account for correlations within individuals, pairs, and groups, we found that pairwise contact rates within a group declined by a factor of three as group sizes increased 33-fold. Per capita contact rates, however, increased with group size according to a power function, such that female elk contact rates fell in between the predictions of density- or frequency-dependent disease models. We found similar patterns for the duration of contacts. Our results suggest that larger elk groups are likely to play a disproportionate role in the disease dynamics of directly transmitted infections in elk. Supplemental feeding of elk had a limited impact on pairwise interaction rates and durations, but per capita rates were more than two times higher on feeding grounds. Our statistical approach decomposes the variation in contact rate into individual, dyadic, and environmental effects, and provides insight into factors that may be targeted by disease control programs. In particular, female elk contact patterns were driven more by environmental factors such as group size than by either individual or dyad effects.

  1. Joint Chiefs of Staff > Directorates > J1 | Manpower and Personnel

    Science.gov Websites

    Management J1 | Manpower and Personnel J2 | Joint Staff Intelligence J3 | Operations J4 | Logistics► J8 | Force Structure, Resources & Assessment Contact J1 Manpower and Personnel Home : Directorates : J1 | Manpower and Personnel Mission To provide the Chairman of the Joint Chiefs of Staff

  2. Comparison of joint torque evoked with monopolar and tripolar-cuff electrodes.

    PubMed

    Tarler, Matthew D; Mortimer, J Thomas

    2003-09-01

    Using a self-sizing spiral-cuff electrode placed on the sciatic nerve of the cat, the joint torque evoked with stimulation applied to contacts in a monopolar configuration was judged to be the same as the torque evoked by stimulation applied to contacts in a tripolar configuration. Experiments were carried out in six acute cat preparations. In each experiment, a 12-contact electrode was placed on the sciatic nerve and used to effect both the monopolar and tripolar electrode configurations. The ankle torque produced by electrically evoked isometric muscle contraction was measured in three dimensions: plantar flexion, internal rotation, and inversion. Based on the recorded ankle torque, qualitative and quantitative comparisons were performed to determine if any significant difference existed in the pattern or order in which motor nerve fibers were recruited. No significant difference was found at a 98% confidence interval in either the recruitment properties or the repeatability of the monopolar and tripolar configurations. Further, isolated activation of single fascicles within the sciatic nerve was observed. Once nerve fibers in a fascicle were activated, recruitment of that fascicle was modulated over the full range before "spill-over" excitation occurred in neighboring fascicles. These results indicate that a four contact, monopolar nerve-cuff electrode is a viable substitute for a 12 contact, tripolar nerve-cuff electrode. The results of this study are also consistent with the hypothesis that multicontact self-sizing spiral-cuff electrodes can be used in motor prostheses to provide selective control of many muscles. These findings should also apply to other neuroprostheses employing-cuff electrodes on nerve trunks.

  3. Protein contact prediction using patterns of correlation.

    PubMed

    Hamilton, Nicholas; Burrage, Kevin; Ragan, Mark A; Huber, Thomas

    2004-09-01

    We describe a new method for using neural networks to predict residue contact pairs in a protein. The main inputs to the neural network are a set of 25 measures of correlated mutation between all pairs of residues in two "windows" of size 5 centered on the residues of interest. While the individual pair-wise correlations are a relatively weak predictor of contact, by training the network on windows of correlation the accuracy of prediction is significantly improved. The neural network is trained on a set of 100 proteins and then tested on a disjoint set of 1033 proteins of known structure. An average predictive accuracy of 21.7% is obtained taking the best L/2 predictions for each protein, where L is the sequence length. Taking the best L/10 predictions gives an average accuracy of 30.7%. The predictor is also tested on a set of 59 proteins from the CASP5 experiment. The accuracy is found to be relatively consistent across different sequence lengths, but to vary widely according to the secondary structure. Predictive accuracy is also found to improve by using multiple sequence alignments containing many sequences to calculate the correlations. Copyright 2004 Wiley-Liss, Inc.

  4. Effects of footwear on lead limb knee and ankle joint kinematics in a fast bowler with a history of posterior ankle joint impingement-a case report.

    PubMed

    Bishop, Chris; Bartold, Simon; Thewlis, Dominic

    2013-11-01

    This case study reports the kinematic effect of 2 different cricket shoes on a fast bowler who reports a history of posterior ankle joint impingement. The participant bowled 6 trials in 2 pairs of cricket shoes. The 3-dimensional kinematics of the joints of the front leg was quantified during stance phase of the delivery stride. Wearing the high-cut shoe resulted in the ankle being 7.7-degree angle more plantarflexed at initial contact compared with the low-cut shoe. Again, when wearing the high-cut shoe compared with the low-cut shoe, the ankle joint was 15.5-degree angle more adducted and the knee was 4.1-degree angle less externally rotated at initial contact. This case study identifies the bowler's preferred shoe (high-cut shoe) as a potential contributing factor to the symptoms he was experiencing.

  5. The influence of hand positions on biomechanical injury risk factors at the wrist joint during the round-off skills in female gymnastics.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2017-01-01

    The aim of this study was to examine the biomechanical injury risk factors at the wrist, including joint kinetics, kinematics and stiffness in the first and second contact limb for parallel and T-shape round-off (RO) techniques. Seven international-level female gymnasts performed 10 trials of the RO to back handspring with parallel and T-shape hand positions. Synchronised kinematic (3D motion analysis system; 247 Hz) and kinetic (two force plates; 1235 Hz) data were collected for each trial. A two-way repeated measure analysis of variance (ANOVA) assessed differences in the kinematic and kinetic parameters between the techniques for each contact limb. The main findings highlighted that in both the RO techniques, the second contact limb wrist joint is exposed to higher mechanical loads than the first contact limb demonstrated by increased axial compression force and loading rate. In the parallel technique, the second contact limb wrist joint is exposed to higher axial compression load. Differences between wrist joint kinetics highlight that the T-shape technique may potentially lead to reducing these bio-physical loads and consequently protect the second contact limb wrist joint from overload and biological failure. Highlighting the biomechanical risk factors facilitates the process of technique selection making more objective and safe.

  6. Free-standing coating patterns fabricated by ultraviolet contact lithography using photosensitive sol-gel coatings

    NASA Astrophysics Data System (ADS)

    Xiang, Youlai; Du, Ai; Li, Xiaoguang; Sun, Wei; Wu, Shuai; Li, Tiemin; Liu, Mingfang; Zhou, Bin

    2017-07-01

    Photosensitive ZrO2-SiO2 hybrid sol-gel coatings containing large contents of chelating rings were prepared by using the zirconium n-butoxide (TBOZ) and methyltriethoxysilane (MTES) as hybrid precursors, and benzoylacetone (BZAC) as chelating agent. The change of ultraviolet (UV) absorption spectra, chemical composition, and optical properties of ZrO2-SiO2 hybrid sol-gel coatings were analyzed before and after UV exposure and calcination. The refractive index of the ZrO2-SiO2 hybrid gel coatings decreased from 1.673 to 1.561 with the increase of the molar content of MTES in precursors. The sol-gel coating patterns with the periods of 20.24 μm, 10.11 μm and 3.99 μm on the PAMS substrates were firstly obtained by using the photosensitive ZrO2-SiO2 hybrid sol-gel films as fundamental materials through a process of UV contact lithography with photo masks and etching with ethanol. Finally, the free-standing gel coating patterns supported by copper grids, with the period of 12.70 μm and line width of 4.93 μm, and the period of 14.20 μm and line width of 3.82 μm, were obtained by removing the PAMS thermal degradation sacrifice layer after being calcined at 330 °C. Micrometer-periodic free-standing gel coating patterns with different structure have potential applications in the laser physical experiments.

  7. Modeling the finger joint moments in a hand at the maximal isometric grip: the effects of friction.

    PubMed

    Wu, John Z; Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E

    2009-12-01

    The interaction between the handle and operator's hand affects the comfort and safety of tool and machine operations. In most of the previous studies, the investigators considered only the normal contact forces. The effect of friction on the joint moments in fingers has not been analyzed. Furthermore, the observed contact forces have not been linked to the internal musculoskeletal loading in the previous experimental studies. In the current study, we proposed a universal model of a hand to evaluate the joint moments in the fingers during grasping tasks. The hand model was developed on the platform of the commercial software package AnyBody. Only four fingers (index, long, ring, and little finger) were included in the model. The anatomical structure of each finger is comprised of four phalanges (distal, middle, proximal, and metacarpal phalange). The simulations were performed using an inverse dynamics technique. The joint angles and the normal contact forces on each finger section reported by previous researchers were used as inputs, while the joint moments of each finger were predicted. The predicted trends of the dependence of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joint moments on the cylinder diameter agree with those of the contact forces on the fingers observed in the previous experimental study. Our results show that the DIP and PIP joint moments reach their maximums at a cylinder diameter of about 31mm, which is consistent with the trend of the finger contact forces measured in the experiments. The proposed approach will be useful for simulating musculoskeletal loading in the hand for occupational activities, thereby optimizing tool-handle design.

  8. A non-contact measurement technique at the micro scale

    NASA Astrophysics Data System (ADS)

    Ghosh, Santaneel

    During their production and normal use, electronic packages experience large temperature excursions, leading to high thermo-mechanical stress gradients that cause fatigue failure of the solder joints. In order to prevent premature failure and prolong the fatigue life of solder joints, there is a pressing need for the characterization of the solder, especially lead-free solder, at the micro-level (joint size). The characterization and modeling of solder behavior at the appropriate scale is a major issue. However, direct measurement techniques are not applicable to characterize the deformation response of solder joints because of their micro scale dimensions. Therefore, a non-contact measurement technique utilizing a Scanning Electron Microscope (SEM) in conjunction with Digital Image Correlation (DIC) has been developed. Validation was achieved by performing a four-point bending test in both an in-house optical system with DIC and inside the SEM. This non-contact measurement technique was then used to extract the stress-strain response of the solder. Mechanical tests were performed on solder joints that were created using the same type of solder balls used in the electronic industry and were representative of normal joint scales. The SEM-DIC technique has been proven to be applicable for the determining the stress-strain response of solder material at the micro-scale. This study resulted in a validated material characterization technique specifically designed for micro-scale material response. One of the main contributions of this study is that the method is a lot simpler and cheaper, yet highly effective, compared to the previous methods. This technique is also readily applicable to the measurement of the stress-strain response of any micro-scale specimen, such as other metals, polymers, etc. Also, the measured displacement field by obtained by DIC can be used as the base for calculating the strain field on the surface of a specimen.

  9. Acromioclavicular joint dislocations: radiological correlation between Rockwood classification system and injury patterns in human cadaver species.

    PubMed

    Eschler, Anica; Rösler, Klaus; Rotter, Robert; Gradl, Georg; Mittlmeier, Thomas; Gierer, Philip

    2014-09-01

    The classification system of Rockwood and Young is a commonly used classification for acromioclavicular joint separations subdividing types I-VI. This classification hypothesizes specific lesions to anatomical structures (acromioclavicular and coracoclavicular ligaments, capsule, attached muscles) leading to the injury. In recent literature, our understanding for anatomical correlates leading to the radiological-based Rockwood classification is questioned. The goal of this experimental-based investigation was to approve the correlation between the anatomical injury pattern and the Rockwood classification. In four human cadavers (seven shoulders), the acromioclavicular and coracoclavicular ligaments were transected stepwise. Radiological correlates were recorded (Zanca view) with 15-kg longitudinal tension applied at the wrist. The resulting acromio- and coracoclavicular distances were measured. Radiographs after acromioclavicular ligament transection showed joint space enlargement (8.6 ± 0.3 vs. 3.1 ± 0.5 mm, p < 0.05) and no significant change in coracoclavicular distance (10.4 ± 0.9 vs. 10.0 ± 0.8 mm). According to the Rockwood classification only type I and II lesions occurred. After additional coracoclavicular ligament cut, the acromioclavicular joint space width increased to 16.7 ± 2.7 vs. 8.6 ± 0.3 mm, p < 0.05. The mean coracoclavicular distance increased to 20.6 ± 2.1 mm resulting in type III-V lesions concerning the Rockwood classification. Trauma with intact coracoclavicular ligaments did not result in acromioclavicular joint lesions higher than Rockwood type I and II. The clinical consequence for reconstruction of low-grade injuries might be a solely surgical approach for the acromioclavicular ligaments or conservative treatment. High-grade injuries were always based on additional structural damage to the coracoclavicular ligaments. Rockwood type V lesions occurred while muscle attachments were intact.

  10. In vivo articular cartilage deformation: noninvasive quantification of intratissue strain during joint contact in the human knee

    NASA Astrophysics Data System (ADS)

    Chan, Deva D.; Cai, Luyao; Butz, Kent D.; Trippel, Stephen B.; Nauman, Eric A.; Neu, Corey P.

    2016-01-01

    The in vivo measurement of articular cartilage deformation is essential to understand how mechanical forces distribute throughout the healthy tissue and change over time in the pathologic joint. Displacements or strain may serve as a functional imaging biomarker for healthy, diseased, and repaired tissues, but unfortunately intratissue cartilage deformation in vivo is largely unknown. Here, we directly quantified for the first time deformation patterns through the thickness of tibiofemoral articular cartilage in healthy human volunteers. Magnetic resonance imaging acquisitions were synchronized with physiologically relevant compressive loading and used to visualize and measure regional displacement and strain of tibiofemoral articular cartilage in a sagittal plane. We found that compression (of 1/2 body weight) applied at the foot produced a sliding, rigid-body displacement at the tibiofemoral cartilage interface, that loading generated subject- and gender-specific and regionally complex patterns of intratissue strains, and that dominant cartilage strains (approaching 12%) were in shear. Maximum principle and shear strain measures in the tibia were correlated with body mass index. Our MRI-based approach may accelerate the development of regenerative therapies for diseased or damaged cartilage, which is currently limited by the lack of reliable in vivo methods for noninvasive assessment of functional changes following treatment.

  11. Contrast Dispersion Pattern and Efficacy of Corticosteroid at the Glenohumeral Joint in Adhesive Capsulitis.

    PubMed

    Kim, Sang Jun; Choi, Yu Seong

    2015-01-01

    Corticosteroid injection has a wide range of success in adhesive capsulitis but the reason for this has not yet been explained. We hypothesized that this difference might be due to the distribution of the corticosteroids injected into the joint cavity because particulate steroid deposits in the capsule and will not be moved over time by shoulder motion. The purpose of this study is to determine whether the therapeutic efficacy of particulate corticosteroid injection into the glenohumeral joint differs according to the dispersion pattern. Prospective evaluation. Outpatient clinics at a tertiary university hospital. Seventy-two patients diagnosed as having adhesive capsulitis received a corticosteroid injection at the glenohumeral joint. The posterior capsule and the subscapular bursa were selected as dispersion sites and the dispersion of contrast dye was expressed as a ratio (%). Two weeks and 3 months after the injection clinical improvement ("not improved," "slightly improved," "much improved"), numeric rating scale (NRS), and passive range of motions (PROM) were evaluated. The dispersion of the contrast dye was compared according to the clinical improvements by an analysis of variance test. Pearson correlation test was done to find the relationship between PROM and the dispersion and between change of NRS and the dispersion. The distribution in the subscapular area was 30.0% in the "much improved" group, 22.0% in the "slightly improved" group, and 37.1% in the "no improvement" group which was not significantly different (P = 0.179). Correlations between changes of NRS and the dye distribution were not statistically significant (P = 0.429 at 2 weeks and P = 0.629 at 3 months). The change of passive external rotation 3 months after the injection was significantly correlated with the dye distribution (P = 0.035). Because of diverse pathologic findings in adhesive capsulitis, further studies will be needed to address the effect of the dye distribution on the pain

  12. Interfacial contact stiffness of fractal rough surfaces.

    PubMed

    Zhang, Dayi; Xia, Ying; Scarpa, Fabrizio; Hong, Jie; Ma, Yanhong

    2017-10-09

    In this work we describe a theoretical model that predicts the interfacial contact stiffness of fractal rough surfaces by considering the effects of elastic and plastic deformations of the fractal asperities. We also develop an original test rig that simulates dovetail joints for turbo machinery blades, which can fine tune the normal contact load existing between the contacting surfaces of the blade root. The interfacial contact stiffness is obtained through an inverse identification method in which finite element simulations are fitted to the experimental results. Excellent agreement is observed between the contact stiffness predicted by the theoretical model and by the analogous experimental results. We demonstrate that the contact stiffness is a power law function of the normal contact load with an exponent α within the whole range of fractal dimension D(1 < D < 2). We also show that for 1 < D < 1.5 the Pohrt-Popov behavior (α = 1/(3 - D)) is valid, however for 1.5 < D < 2, the exponent α is different and equal to 2(D - 1)/D. The diversity between the model developed in the work and the Pohrt-Popov one is explained in detail.

  13. Frequency and patterns of contact with domestic poultry and potential risk of H5N1 transmission to humans living in rural Cambodia

    PubMed Central

    Van Kerkhove, Maria D.; Ly, Sowath; Holl, Davun; Guitian, Javier; Mangtani, Punam; Ghani, Azra C.; Vong, Sirenda

    2008-01-01

    Background  Since 2004, H5N1 outbreaks have been recurrent in domestic poultry and humans in Cambodia. To date, seven human cases (100% CFR) and 22 outbreaks in poultry have been confirmed. Household ownership of backyard poultry (FAO Sector 4 poultry production) in rural Cambodia is high. An understanding of the extent and frequency of poultry handing behaviors in these settings is necessary to assess the risk associated with different practices and to formulate sensible recommendations to mitigate this risk. We collected new data from six geographic regions to examine patterns of human contact with poultry among rural farmers in Cambodia and identify populations with the highest potential exposure to H5N1. Methods and Findings  A cross‐sectional survey was undertaken in which 3,600 backyard poultry owners from 115 randomly selected villages in six provinces throughout Cambodia were interviewed. Using risk assessment methods, patterns of contact with poultry as surrogate measures of exposure to H5N1 were used to generate risk indices of potential H5N1 transmission to different populations in contact with poultry. Estimates of human exposure risk for each study participant (n = 3600) were obtained by multiplying each reported practice with a transmission risk‐weighting factor and summing these over all practices reported by each individual. Exposure risk estimates were then examined stratified by age and gender. Subjects reported high contact with domestic poultry (chickens and ducks) through the daily care and food preparation practices, however contact patterns varied by gender and age. Males between the ages of 26‐40 reported practices of contact with poultry that give rise to the highest H5N1 transmission risk potential, followed closely by males between the ages of 16‐25. Overall, males had a higher exposure risk potential than females across all age groups (p < 0·001). Conclusions  Our results demonstrate that most of the population in

  14. The effect of age and knee osteoarthritis on muscle activation patterns and knee joint biomechanics during dual belt treadmill gait.

    PubMed

    Rutherford, Derek; Baker, Matthew; Wong, Ivan; Stanish, William

    2017-06-01

    To compare a group of individuals with moderate medial compartment knee osteoarthritis (OA) to both an age-matched asymptomatic group of older adults and younger adults to determine whether differences in knee joint muscle activation patterns and joint biomechanics exist during gait between these three groups. 20 young adults, 20 older adults, and 40 individuals with moderate knee OA were recruited. Using standardized procedures, surface electromyograms were recorded from the vastus lateralis and medialis, rectus femoris and the medial and lateral hamstrings. All individuals walked on a dual belt instrumented treadmill while segment motions and ground reaction forces were recorded. Sagittal plane motion and net external sagittal and frontal plane moments were calculated. Discrete measures and principal component analyses extracted amplitude and temporal waveform features. Analysis of Variance models using Bonferroni corrections determined between and within group differences in these gait features (α=0.05). Individuals with knee OA have distinct biomechanics and muscle activation patterns when compared to age-matched asymptomatic adults and younger adults whereas differences between the young and older adults were few and included only measures of muscle activation amplitude. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Characterization of Sheet Fracture Patterns in Polygonal-Jointed Lavas at Kokostick Butte, OR, and Mazama Ridge, WA: Investigation and Interpretation of Their Formation and Significance

    NASA Astrophysics Data System (ADS)

    Lodge, R. W.; Lescinsky, D. T.

    2006-12-01

    Polygonal joints in lava flows ("columns") are commonly equant leading to a model of formation associated with cooling in an isotropic stress field. This model, however, does not explain rectangular columns, sheet-like fractures, fractures with crosscutting relationships, and fractures with orientations other than perpendicular to the cooling surface. These fracture patterns are often observed at glaciated volcanoes. The presence of preferential fracture orientations suggests an applied stress component likely due to environmental conditions such as the presence of glaciers or flow dynamics such as down-slope settling or flow margin inflation. During this study we investigated the formation and significance of these non-equant fracture patterns to propose a model for their formation. These `abnormal' fracture patterns have not been discussed in the literature and may be important to better understanding the cooling conditions of such lava flows. To test these possibilities we studied Kokostick Butte dacite flow, OR (near South Sister), and Mazama Ridge andesite flow at Mount Rainier, WA. Both of these flows have well developed sheet-like fractures and display evidence of ice-contact during eruption and emplacement. Sheet fractures are long and continuous fractures that have perpendicular connecting fractures forming rectangular columns. The sheet-like fractures are largely parallel to each other on the exposure surface and the connecting fractures vary locally from primary fractures (associated with cooling toward flow interior) to secondary fractures (associated with cooling by water infiltration). Detailed measurements of fracture orientations and spacing were collected at Kokostick Butte and Mazama Ridge to examine the relationship between the sheet fractures and flow geometry. Preliminary results support this relationship and suggest these patterns likely form due to shear associated with small amounts of flow advance by the rapidly cooling lava. Laboratory

  16. Geophysical Signatures of Shear-Induced Damage and Frictional Processes on Rock Joints

    NASA Astrophysics Data System (ADS)

    Hedayat, Ahmadreza; Haeri, Hadi; Hinton, John; Masoumi, Hossein; Spagnoli, Giovanni

    2018-02-01

    In this study, ultrasonic waves recorded during direct shear experiments on rock joints were employed to investigate the shear failure processes. Three types of wave attributes were systematically observed prior to the shear failure of the rock joints: (a) maximum in the amplitude of the transmitted wave, (b) maximum in the dominant frequency of the transmitted wave, and (c) maximum in the velocity of the wave. Different processes occurring during both frictional sliding and stick-slip oscillations were identified in this study: (a) interseismic phase and (b) preseismic phase. The interseismic phase is associated with elastic loading, very small local slip rate, and increasing ultrasonic transmission along the contact surfaces. The rock joint is considered locked, and the increase in ultrasonic transmission represents an increase in the real (true) area of contact because of interlocking and contact aging. The start of the preseismic phase is marked by the onset of precursors for different regions of the rock joint. Following the interseismic and preseismic phases, coseismic phase occurs. The coseismic phase begins with the reduction in the applied shear stress and is associated with an abrupt increase in the local slip rate. The reductions in transmitted amplitude, wave velocity, and dominant frequency all indicate the preseismic phase when the asperity contacts begin to fail before macroscopic frictional sliding. The observation of the preseismic phase in both the loading phase leading to stable sliding and stick-slip failure modes suggests that microphysical processes of fault weakening may share key features for these two failure modes.

  17. Bolted Double-Lap Composite Joints Under Mechanical and Thermal Loading

    NASA Technical Reports Server (NTRS)

    Kradinov, V.; Barut, A.; Madenci, E.; Walker, Sandra P. (Technical Monitor)

    2000-01-01

    This study concerns the determination of the contact stresses and contact region around bolt holes and the bolt load distribution in single- and double-lap joints of composite laminates with arbitrarily located bolts under general mechanical loading conditions and uniform temperature change. The unknown contact stress distribution and contact region between the bolt and laminates and the interaction among the bolts require the bolt load distribution, as well as the contact stresses, to be as part of the solution. The present method is based on the complex potential theory and the variational formulation in order to account for bolt stiffness, bolt-hole clearance, and finite geometry of the composite laminates.

  18. Towards non-contact photo-acoustic endoscopy using speckle pattern analysis

    NASA Astrophysics Data System (ADS)

    Lengenfelder, Benjamin; Mehari, Fanuel; Tang, Yuqi; Klämpfl, Florian; Zalevsky, Zeev; Schmidt, Michael

    2017-03-01

    Photoacoustic Tomography combines the advantages of optical and acoustic imaging as it makes use of the high optical contrast of tissue and the high resolution of ultrasound. Furthermore, high penetration depths in tissue in the order of several centimeters can be achieved by the combination of these modalities. Extensive research is being done in the field of miniaturization of photoacoustic devices, as photoacoustic imaging could be of significant benefits for the physician during endoscopic interventions. All the existing miniature systems are based on contact transducers for signal detection that are placed at the distal end of an endoscopic device. This makes the manufacturing process difficult and impedance matching to the inspected surface a requirement. The requirement for contact limits the view of the physician during the intervention. Consequently, a fiber based non-contact optical sensing technique would be highly beneficial for the development of miniaturized photoacoustic endoscopic devices. This work demonstrates the feasibility of surface displacement detection using remote speckle-sensing using a high speed camera and an imaging fiber bundle that is used in commercially available video endoscopes. The feasibility of displacement sensing is demonstrated by analysis of phantom vibrations which are induced by loudspeaker membrane oscillations. Since the usability of the remote speckle-sensing for photo-acoustic signal detection was already demonstrated, the fiber bundle approach demonstrates the potential for non-contact photoacoustic detections during endoscopy.

  19. Impact of the difference in the plantar flexor strength of the ankle joint in the affected side among hemiplegic patients on the plantar pressure and walking asymmetry.

    PubMed

    You, Young Youl; Chung, Sin Ho; Lee, Hyung Jin

    2016-11-01

    [Purpose] This study was to examine the changes in the gait lines and plantar pressures in static and dynamic circumstances, according to the differences in the strengths of the plantar flexors in the ankle joints on the affected sides of hemiplegic patients, and to determine their impacts on walking symmetry. [Subjects and Methods] A total of thirty hospitalized stroke patients suffering from hemiplegia were selected in this study. The subjects had ankylosing patterns in the ankle joints of the affected sides. Fifteen of the patients had plantar flexor manual muscle testing scores between poor and fair, while fifteen of the patients had zero and trace. [Results] The contact pattern of the plantar surface with the ground is a reliable method for walking analysis, which is an important index for understanding the ankle mechanism and the relationship between the plantar surface and the ground. [Conclusion] The functional improvement of patients with stroke could be supported through a verification of the analysis methods of the therapy strategy and walking pattern.

  20. Joint Chiefs of Staff > Directorates > J5 | Strategic Plans and Policy

    Science.gov Websites

    Quadrilateral Logistics Forum J5 | Strategic Plans and Policy J6 | C4 & Cyber J7 | Joint Force Development J8 | Force Structure, Resources & Assessment Contact J5 Strategic Plans and Policy Home : Directorates : J5 | Strategic Plans and Policy Mission The Joint Staff J5 proposes strategies, plans, and

  1. Hip and knee joint loading during vertical jumping and push jerking

    PubMed Central

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony MJ

    2014-01-01

    Background The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. Methods In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. Findings The knee experienced mean peak loadings of 2.4-4.6 × body weight at the patellofemoral joint, 6.9-9.0 × body weight at the tibiofemoral joint, 0.3-1.4 × body weight anterior tibial shear and 1.0-3.1 × body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4 × body weight and the ankle 8.9-10.0 × body weight. Interpretation The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. PMID:23146164

  2. Photonic Choke-Joints for Dual-Polarization Waveguides

    NASA Technical Reports Server (NTRS)

    Wollack, Edward J.; U-yen, Kongpop; Chuss, David T.

    2010-01-01

    Photonic choke joint (PCJ) structures for dual-polarization waveguides have been investigated for use in device and component packaging. This interface enables the realization of a high performance non-contacting waveguide joint without degrading the in-band signal propagation properties. The choke properties of two tiling approaches, symmetric square Cartesian and octagonal quasi-crystal lattices of metallic posts, are explored and optimal PCJ design parameters are presented. For each of these schemes, the experimental results for structures with finite tilings demonstrate near ideal transmission and reflection performance over a full waveguide band.

  3. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  4. Non-contact finger vein acquisition system using NIR laser

    NASA Astrophysics Data System (ADS)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  5. Heterochrony and patterns of cranial suture closure in hystricognath rodents

    PubMed Central

    Wilson, Laura A B; Sánchez-Villagra, Marcelo R

    2009-01-01

    Sutures, joints that allow one bone to articulate with another through intervening fibrous connective tissue, serve as major sites of bone expansion during postnatal craniofacial growth in the vertebrate skull and represent an aspect of cranial ontogeny which may exhibit functional and phylogenetic correlates. Suture evolution among hystricognath rodents, an ecologically diverse group represented here by 26 species, is examined using sequence heterochrony methods, i.e. event pairing and parsimov. Although minor nuances in suture closure sequence exist between species, the overall sequence was found to be conserved both across the hystricognath group and, to an increasing degree, within selected clades. At species level, suture closure pattern exhibited a significant positive correlation with patterns previously reported for hominoids. Patterns for most clades revealed the first sutures to close are those contacting the exoccipital, interparietal, and palatine bones. Heterochronic shifts were found along 19 of 35 branches within the hystricognath phylogeny. The number of shifts per node ranged from one to seven events and, overall, involved 21 of 34 suture sites. The topology generated by parsimony analyses of the event pair matrix yielded only one grouping that was congruent with the evolutionary relationships, compiled from morphological and molecular studies, taken as framework. Sutures contacting the exoccipital displayed the highest levels of most complete closure across all species. Level of suture closure is negatively correlated with cranial length (P < 0.05). Differing life history and locomotory strategies are coupled in part with differing suture closure patterns among several species. PMID:19245501

  6. Neuromusculoskeletal Model Calibration Significantly Affects Predicted Knee Contact Forces for Walking

    PubMed Central

    Serrancolí, Gil; Kinney, Allison L.; Fregly, Benjamin J.; Font-Llagunes, Josep M.

    2016-01-01

    Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patient-specific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel two-level optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outer-level optimization adjusted time-invariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the inner-level optimization predicted time-varying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher

  7. Patterns of Joint Improvisation in Adults with Autism Spectrum Disorder.

    PubMed

    Brezis, Rachel-Shlomit; Noy, Lior; Alony, Tali; Gotlieb, Rachel; Cohen, Rachel; Golland, Yulia; Levit-Binnun, Nava

    2017-01-01

    Recent research on autism spectrum disorders (ASDs) suggests that individuals with autism may have a basic deficit in synchronizing with others, and that this difficulty may lead to more complex social and communicative deficits. Here, we examined synchronization during an open-ended joint improvisation (JI) paradigm, called the mirror game (MG). In the MG, two players take turns leading, following, and jointly improvising motion using two handles set on parallel tracks, while their motion tracks are recorded with high temporal and spatial resolution. A series of previous studies have shown that players in the MG attain moments of highly synchronized co-confident (CC) motion, in which there is no typical kinematic pattern of leader and reactive follower. It has been suggested that during these moments players act as a coupled unit and feel high levels of connectedness. Here, we aimed to assess whether participants with ASD are capable of attaining CC, and whether their MG performance relates to broader motor and social skills. We found that participants with ASD ( n = 34) can indeed attain CC moments when playing with an expert improviser, though their performance was attenuated in several ways, compared to typically developing (TD) participants ( n = 35). Specifically, ASD participants had lower rates of CC, compared with TD participants, which was most pronounced during the following rounds. In addition, the duration of their CC segments was shorter, across all rounds. When controlling for participants' motor skills (both on the MG console, and more broadly) some of the variability in MG performance was explained, but group differences remained. ASD participants' alexithymia further correlated with their difficulty following another's lead; though other social skills did not relate to MG performance. Participants' subjective reports of the game suggest that other cognitive and emotional factors, such as attention, motivation, and reward-processing, which were not

  8. Patterns of Joint Improvisation in Adults with Autism Spectrum Disorder

    PubMed Central

    Brezis, Rachel-Shlomit; Noy, Lior; Alony, Tali; Gotlieb, Rachel; Cohen, Rachel; Golland, Yulia; Levit-Binnun, Nava

    2017-01-01

    Recent research on autism spectrum disorders (ASDs) suggests that individuals with autism may have a basic deficit in synchronizing with others, and that this difficulty may lead to more complex social and communicative deficits. Here, we examined synchronization during an open-ended joint improvisation (JI) paradigm, called the mirror game (MG). In the MG, two players take turns leading, following, and jointly improvising motion using two handles set on parallel tracks, while their motion tracks are recorded with high temporal and spatial resolution. A series of previous studies have shown that players in the MG attain moments of highly synchronized co-confident (CC) motion, in which there is no typical kinematic pattern of leader and reactive follower. It has been suggested that during these moments players act as a coupled unit and feel high levels of connectedness. Here, we aimed to assess whether participants with ASD are capable of attaining CC, and whether their MG performance relates to broader motor and social skills. We found that participants with ASD (n = 34) can indeed attain CC moments when playing with an expert improviser, though their performance was attenuated in several ways, compared to typically developing (TD) participants (n = 35). Specifically, ASD participants had lower rates of CC, compared with TD participants, which was most pronounced during the following rounds. In addition, the duration of their CC segments was shorter, across all rounds. When controlling for participants’ motor skills (both on the MG console, and more broadly) some of the variability in MG performance was explained, but group differences remained. ASD participants’ alexithymia further correlated with their difficulty following another’s lead; though other social skills did not relate to MG performance. Participants’ subjective reports of the game suggest that other cognitive and emotional factors, such as attention, motivation, and reward-processing, which

  9. A new method for measuring low resistivity contacts between silver and YBa2Cu3O(7-x) superconductor

    NASA Technical Reports Server (NTRS)

    Hsi, Chi-Shiung; Haertling, Gene H.; Sherrill, Max D.

    1991-01-01

    Several methods of measuring contact resistivity between silver electrodes and YBa2Cu3O(7-x) superconductors were investigated; including the two-point, the three point, and the lap-joint methods. The lap-joint method was found to yield the most consistent and reliable results and is proposed as a new technique for this measurement. Painting, embedding, and melting methods were used to apply the electrodes to the superconductor. Silver electrodes produced good ohmic contacts to YBa2Cu3O(7-x) superconductors with contact resistivities as low as 1.9 x 10 to the -9th ohm sq cm.

  10. Comparison between FEBio and Abaqus for biphasic contact problems.

    PubMed

    Meng, Qingen; Jin, Zhongmin; Fisher, John; Wilcox, Ruth

    2013-09-01

    Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated.

  11. Comparison between FEBio and Abaqus for biphasic contact problems

    PubMed Central

    Jin, Zhongmin; Fisher, John; Wilcox, Ruth

    2013-01-01

    Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated. PMID:23804955

  12. An Improved Tibial Force Sensor to Compute Contact Forces and Contact Locations In Vitro After Total Knee Arthroplasty.

    PubMed

    Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2017-04-01

    Contact force imbalance and contact kinematics (i.e., motion of the contact location in each compartment during flexion) of the tibiofemoral joint are both important predictors of a patient's outcome following total knee arthroplasty (TKA). Previous tibial force sensors have limitations in that they either did not determine contact forces and contact locations independently in the medial and lateral compartments or only did so within restricted areas of the tibial insert, which prevented them from thoroughly evaluating contact force imbalance and contact kinematics in vitro. Accordingly, the primary objective of this study was to present the design and verification of an improved tibial force sensor which overcomes these limitations. The improved tibial force sensor consists of a modified tibial baseplate which houses independent medial and lateral arrays of three custom tension-compression transducers each. This sensor is interchangeable with a standard tibial component because it accommodates tibial articular surface inserts with a range of sizes and thicknesses. This sensor was verified by applying known loads at known locations over the entire surface of the tibial insert to determine the errors in the computed contact force and contact location in each compartment. The root-mean-square errors (RMSEs) in contact force are ≤ 6.1 N which is 1.4% of the 450 N full-scale output. The RMSEs in contact location are ≤ 1.6 mm. This improved tibial force sensor overcomes the limitations of the previous sensors and therefore should be useful for in vitro evaluation of new alignment goals, new surgical techniques, and new component designs in TKA.

  13. Variations in contact patterns and dispatch guideline adherence between Norwegian emergency medical communication centres - a cross-sectional study

    PubMed Central

    2014-01-01

    Background The 19 Norwegian Emergency medical communication centres (EMCCs) use Norwegian Index for medical emergency assistance (Index) as dispatch guidelines. Little is known about the use of Index, nor its validity. We aimed to document the epidemiology of contacts made to the public emergency medical phone number and the operators’ self-reported use of Index as a first step towards a validation study. Methods We registered all medical emergency calls to the EMCCs during a 72 h period in a national cross sectional study. We subsequently sent a questionnaire to all EMCC operators in Norway, asking how they use Index. A combined outcome variable “use of Index” was computed through a Likert scale, range 1–5. Regression models were used to examine factors influencing use. Results 2 298 contacts were included. National contact rate was 56/1 000 inhabitants per year, range between EMCCs 34 – 119. Acute contact (life-threatening situations) rate was 21/1 000 per year, range between EMCCs 5 – 31. Index criteria 6 – ’Unresolved problem’ accounts for 20% of the 113 contacts, range between EMCCs 10 – 42%. The mean use of Index was 3.95 (SD 0.39), corresponding to “more than 75% of emergency calls”. There were differences in use of Index on EMCC level, range 3.7 – 4.4, and a multi regression model explained 23.4% of the variation in use. Operators working rotation with ground ambulance services reported reduced use of Index compared to operators not working in rotation, while distinct EMCC focus on Index increased use of Index compared to EMCCs with no focus on Index. Use of electronic records and operators experience were the main reasons given for not using Index. Conclusions There is a large variation between the EMCCs with regard to both contact patterns and use of Index. There is a relatively high overall self-reported use of Index by the operators, with variations on both individual and EMCC level. PMID:24398290

  14. Development of a Subject-Specific Foot-Ground Contact Model for Walking.

    PubMed

    Jackson, Jennifer N; Hass, Chris J; Fregly, Benjamin J

    2016-09-01

    Computational walking simulations could facilitate the development of improved treatments for clinical conditions affecting walking ability. Since an effective treatment is likely to change a patient's foot-ground contact pattern and timing, such simulations should ideally utilize deformable foot-ground contact models tailored to the patient's foot anatomy and footwear. However, no study has reported a deformable modeling approach that can reproduce all six ground reaction quantities (expressed as three reaction force components, two center of pressure (CoP) coordinates, and a free reaction moment) for an individual subject during walking. This study proposes such an approach for use in predictive optimizations of walking. To minimize complexity, we modeled each foot as two rigid segments-a hindfoot (HF) segment and a forefoot (FF) segment-connected by a pin joint representing the toes flexion-extension axis. Ground reaction forces (GRFs) and moments acting on each segment were generated by a grid of linear springs with nonlinear damping and Coulomb friction spread across the bottom of each segment. The stiffness and damping of each spring and common friction parameter values for all springs were calibrated for both feet simultaneously via a novel three-stage optimization process that used motion capture and ground reaction data collected from a single walking trial. The sequential three-stage process involved matching (1) the vertical force component, (2) all three force components, and finally (3) all six ground reaction quantities. The calibrated model was tested using four additional walking trials excluded from calibration. With only small changes in input kinematics, the calibrated model reproduced all six ground reaction quantities closely (root mean square (RMS) errors less than 13 N for all three forces, 25 mm for anterior-posterior (AP) CoP, 8 mm for medial-lateral (ML) CoP, and 2 N·m for the free moment) for both feet in all walking trials. The

  15. Development of a Subject-Specific Foot-Ground Contact Model for Walking

    PubMed Central

    Jackson, Jennifer N.; Hass, Chris J.; Fregly, Benjamin J.

    2016-01-01

    Computational walking simulations could facilitate the development of improved treatments for clinical conditions affecting walking ability. Since an effective treatment is likely to change a patient's foot-ground contact pattern and timing, such simulations should ideally utilize deformable foot-ground contact models tailored to the patient's foot anatomy and footwear. However, no study has reported a deformable modeling approach that can reproduce all six ground reaction quantities (expressed as three reaction force components, two center of pressure (CoP) coordinates, and a free reaction moment) for an individual subject during walking. This study proposes such an approach for use in predictive optimizations of walking. To minimize complexity, we modeled each foot as two rigid segments—a hindfoot (HF) segment and a forefoot (FF) segment—connected by a pin joint representing the toes flexion–extension axis. Ground reaction forces (GRFs) and moments acting on each segment were generated by a grid of linear springs with nonlinear damping and Coulomb friction spread across the bottom of each segment. The stiffness and damping of each spring and common friction parameter values for all springs were calibrated for both feet simultaneously via a novel three-stage optimization process that used motion capture and ground reaction data collected from a single walking trial. The sequential three-stage process involved matching (1) the vertical force component, (2) all three force components, and finally (3) all six ground reaction quantities. The calibrated model was tested using four additional walking trials excluded from calibration. With only small changes in input kinematics, the calibrated model reproduced all six ground reaction quantities closely (root mean square (RMS) errors less than 13 N for all three forces, 25 mm for anterior–posterior (AP) CoP, 8 mm for medial–lateral (ML) CoP, and 2 N·m for the free moment) for both feet in all walking

  16. Contact angle hysteresis on doubly periodic smooth rough surfaces in Wenzel's regime: The role of the contact line depinning mechanism

    NASA Astrophysics Data System (ADS)

    Iliev, Stanimir; Pesheva, Nina; Iliev, Pavel

    2018-04-01

    We report here on the contact angle hysteresis, appearing when a liquid meniscus is in contact with doubly sinusoidal wavelike patterned surfaces in Wenzel's wetting regime. Using the full capillary model we obtain numerically the contact angle hysteresis as a function of the surface roughness factor and the equilibrium contact angle for a block case and a kink case contact line depinning mechanism. We find that the dependencies of the contact angle hysteresis on the surface roughness factor are different for the different contact line depinning mechanisms. These dependencies are different also for the two types of rough surfaces we studied. The relations between advancing, receding, and equilibrium contact angles are investigated. A comparison with the existing asymptotical, numerical, and experimental results is carried out.

  17. Contact angle hysteresis on doubly periodic smooth rough surfaces in Wenzel's regime: The role of the contact line depinning mechanism.

    PubMed

    Iliev, Stanimir; Pesheva, Nina; Iliev, Pavel

    2018-04-01

    We report here on the contact angle hysteresis, appearing when a liquid meniscus is in contact with doubly sinusoidal wavelike patterned surfaces in Wenzel's wetting regime. Using the full capillary model we obtain numerically the contact angle hysteresis as a function of the surface roughness factor and the equilibrium contact angle for a block case and a kink case contact line depinning mechanism. We find that the dependencies of the contact angle hysteresis on the surface roughness factor are different for the different contact line depinning mechanisms. These dependencies are different also for the two types of rough surfaces we studied. The relations between advancing, receding, and equilibrium contact angles are investigated. A comparison with the existing asymptotical, numerical, and experimental results is carried out.

  18. Network analysis of pig movements: Loyalty patterns and contact chains of different holding types in Denmark

    PubMed Central

    Boklund, Anette; Halasa, Tariq H. B.; Toft, Nils; Lentz, Hartmut H. K.

    2017-01-01

    Understanding animal movements is an important factor for the development of meaningful surveillance and control programs, but also for the development of disease spread models. We analysed the Danish pig movement network using static and temporal network analysis tools to provide deeper insight in the connection between holdings dealing with pigs, such as breeding and multiplier herds, production herds, slaughterhouses or traders. Pig movements, which occurred between 1st January 2006 and 31st December 2015 in Denmark, were summarized to investigate temporal trends such as the number of active holdings, the number of registered movements and the number of pigs moved. To identify holdings and holding types with potentially higher risk for introduction or spread of diseases via pig movements, we determined loyalty patterns, annual network components and contact chains for the 24 registered holding types. The total number of active holdings as well as the number of pig movements decreased during the study period while the holding sizes increased. Around 60–90% of connections between two pig holdings were present in two consecutive years and around one third of the connections persisted within the considered time period. Weaner herds showed the highest level of in-loyalty, whereas we observed an intermediate level of in-loyalty for all breeding sites and for production herds. Boar stations, production herds and trade herds showed a high level of out-loyalty. Production herds constituted the highest proportion of holdings in the largest strongly connected component. All production sites showed low levels of in-going contact chains and we observed a high level of out-going contact chain for breeding and multiplier herds. Except for livestock auctions, all transit sites also showed low levels of out-going contact chains. Our results reflect the pyramidal structure of the underlying network. Based on the considered disease, the time frame for the calculation of network

  19. Network analysis of pig movements: Loyalty patterns and contact chains of different holding types in Denmark.

    PubMed

    Schulz, Jana; Boklund, Anette; Halasa, Tariq H B; Toft, Nils; Lentz, Hartmut H K

    2017-01-01

    Understanding animal movements is an important factor for the development of meaningful surveillance and control programs, but also for the development of disease spread models. We analysed the Danish pig movement network using static and temporal network analysis tools to provide deeper insight in the connection between holdings dealing with pigs, such as breeding and multiplier herds, production herds, slaughterhouses or traders. Pig movements, which occurred between 1st January 2006 and 31st December 2015 in Denmark, were summarized to investigate temporal trends such as the number of active holdings, the number of registered movements and the number of pigs moved. To identify holdings and holding types with potentially higher risk for introduction or spread of diseases via pig movements, we determined loyalty patterns, annual network components and contact chains for the 24 registered holding types. The total number of active holdings as well as the number of pig movements decreased during the study period while the holding sizes increased. Around 60-90% of connections between two pig holdings were present in two consecutive years and around one third of the connections persisted within the considered time period. Weaner herds showed the highest level of in-loyalty, whereas we observed an intermediate level of in-loyalty for all breeding sites and for production herds. Boar stations, production herds and trade herds showed a high level of out-loyalty. Production herds constituted the highest proportion of holdings in the largest strongly connected component. All production sites showed low levels of in-going contact chains and we observed a high level of out-going contact chain for breeding and multiplier herds. Except for livestock auctions, all transit sites also showed low levels of out-going contact chains. Our results reflect the pyramidal structure of the underlying network. Based on the considered disease, the time frame for the calculation of network

  20. Clinical and radiographic study of bone and joint lesions in 26 dogs with leishmaniasis.

    PubMed

    Agut, A; Corzo, N; Murciano, J; Laredo, F G; Soler, M

    2003-11-22

    Twenty-six dogs with parasitologically confirmed leishmaniasis and abnormalities of gait were studied to determine the most common radiological patterns of bone and joint lesions. The clinical findings included either lameness, joint pain and crepitation, soft tissue swelling and/or muscle atrophy. Bone lesions were observed radiographically in 12 of the 26 dogs; the radius and ulna were affected in seven, the tibia in six and the femur in six. Joint lesions were observed radiographically in 15 of the 26 dogs; the carpus and stifle were affected in all 15, and the tarsus in nine. There was a tendency for the bones and joints to be affected bilaterally. The radiographic patterns observed were different in the long bones and the joints. In the long bones, the most common pattern was periosteal and intramedullary proliferation, involving the diaphyses and related to the nutrient foramen; in the joints, two patterns, either non-erosive or erosive polyarthritis with soft-tissue swelling, were observed. The changes observed in the synovial fluid were associated in most cases with osteolytic lesions. However, Leishmania organisms were identified in the synovial fluid from joints without bony radiographic changes.

  1. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    PubMed Central

    Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia

    2017-01-01

    The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725

  2. Jointing patterns and tectonic evolution of the Maciço Calcário Estremenho, Lusitanian Basin, Portugal

    NASA Astrophysics Data System (ADS)

    Carvalho, Jorge M. F.

    2018-05-01

    The Maciço Calcário Estremenho (MCE) is an uplifted Jurassic limestone massif unit of the Lusitanian Basin, Portugal, where five main joint sets trending NNE-SSW, WSW-ENE, WNW-ESE, NW-SE, and NNW-SSE are recognized. Except for the NNW-SSE set, all the other sets host calcite veins and barren joints, evidencing a multistage development by several deformation episodes, including shear reactivation. Orthogonal patterns defined by the NNE-SSW/WNW-ESE and NNW-SSE/WSW-ENE systems are characteristic of some tectonostratigraphic units of the MCE, but the sets of each one of the systems are genetically independent. They result from specific deformation episodes undergone by the studied area in the course of its Meso-Cenozoic evolution. NNE-SSW calcite veins were the first to form during Middle Jurassic fault-controlled subsidence. A renewal of this set as barren joints took place during the Eocene Pyrenean compressive phase. The WSW-ENE and WNW-ESE sets have a restricted spatial distribution and relate to transient compressive episodes of the Middle - Late Jurassic and Jurassic - Cretaceous transitions, respectively. The NW-SE set, also characteristic of a specific region, formed during the Late Jurassic rifting and is related to local NE-SW tension dependent on block tilting towards a major NW-SE fault. The Miocene Betic compressive phase is responsible for the formation of the NNW-SSE set, which is widespread throughout the MCE.

  3. Seismic Strengthening of Carpentry Joints in Traditional Timber Structures

    NASA Astrophysics Data System (ADS)

    Parisi, Maria A.; Cordié, Cinzia; Piazza, Maurizio

    2008-07-01

    The static and dynamic behavior of timber structures largely depends on their connections. In traditional timber construction, elements are usually connected with carpentry joints based on contact pressure and friction, often with only minor reinforcement generically intended to avoid disassembling. In current practice, interventions for the upgrading of carpentry joints are mainly based on empirical knowledge according to tradition. Often they produce a general strengthening of the connection, but are not specific for the case of seismic action. Strengthening on heuristic bases may be only partially effective or possibly disproportioned. The behavior of the carpentry joints most used in roof structures is examined. The birdsmouth joint, connecting rafters to the tie beam, has been studied first, characterizing its behavior numerically and experimentally in monotonic and cyclic conditions. Other forms of the rafter-to-tie connection, the double notch joint and the case of parallel rafters, are discussed. Some general criteria for the seismic strengthening of these joints are presented.

  4. Allergic contact dermatitis from sculptured acrylic nails: special presentation with an airborne pattern

    PubMed Central

    Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2012-01-01

    Methylmethacrylate was first reported in 1941 as a cause of contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and industry have been reported, but few reports are found in the literature as a consequence of the contact with sculptured artificial acrylic nails which are increasingly popular. We describe here 3 patients with contact allergy to acrylates in artificial sculptured nails. Patch tests were performed with the Portuguese baseline series of contact allergens and an extended series of acrylates were applied. In particular, we tested three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one presented only with face and eyelid dermatitis had no other lesions. The tests showed positive reaction to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in all the three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic sculptured nails. They show the need to warn patients of persistent and sometimes permanent side effects of these products. They also emphasize the importance of cosmetic ingredient labeling. PMID:25386316

  5. Electrical resistance determination of actual contact area of cold welded metal joints

    NASA Technical Reports Server (NTRS)

    Hordon, M. J.

    1970-01-01

    Method measures the area of the bonded zone of a compression weld by observing the electrical resistance of the weld zone while the load changes from full compression until the joint ruptures under tension. The ratio of bonding force to maximum tensile load varies considerably.

  6. Hip and knee joint loading during vertical jumping and push jerking.

    PubMed

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony M J

    2013-01-01

    The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. The knee experienced mean peak loadings of 2.4-4.6×body weight at the patellofemoral joint, 6.9-9.0×body weight at the tibiofemoral joint, 0.3-1.4×body weight anterior tibial shear and 1.0-3.1×body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4×body weight and the ankle 8.9-10.0×body weight. The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Phalangeal joints kinematics during ostrich (Struthio camelus) locomotion

    PubMed Central

    Ji, Qiaoli; Luo, Gang; Xue, Shuliang; Ma, Songsong; Li, Jianqiao

    2017-01-01

    The ostrich is a highly cursorial bipedal land animal with a permanently elevated metatarsophalangeal joint supported by only two toes. Although locomotor kinematics in walking and running ostriches have been examined, these studies have been largely limited to above the metatarsophalangeal joint. In this study, kinematic data of all major toe joints were collected from gaits with double support (slow walking) to running during stance period in a semi-natural setup with two selected cooperative ostriches. Statistical analyses were conducted to investigate the effect of locomotor gait on toe joint kinematics. The MTP3 and MTP4 joints exhibit the largest range of motion whereas the first phalangeal joint of the 4th toe shows the largest motion variability. The interphalangeal joints of the 3rd and 4th toes present very similar motion patterns over stance phases of slow walking and running. However, the motion patterns of the MTP3 and MTP4 joints and the vertical displacement of the metatarsophalangeal joint are significantly different during running and slow walking. Because of the biomechanical requirements, osctriches are likely to select the inverted pendulum gait at low speeds and the bouncing gait at high speeds to improve movement performance and energy economy. Interestingly, the motions of the MTP3 and MTP4 joints are highly synchronized from slow to fast locomotion. This strongly suggests that the 3rd and 4th toes really work as an “integrated system” with the 3rd toe as the main load bearing element whilst the 4th toe as the complementary load sharing element with a primary role to ensure the lateral stability of the permanently elevated metatarsophalangeal joint. PMID:28097064

  8. [Keratoconus special soft contact lens fitting].

    PubMed

    Yamazaki, Ester Sakae; da Silva, Vanessa Cristina Batista; Morimitsu, Vagner; Sobrinho, Marcelo; Fukushima, Nelson; Lipener, César

    2006-01-01

    To evaluate the fitting and use of a soft contact lens in keratoconic patients. Retrospective study on 80 eyes of 66 patients, fitted with a special soft contact lens for keratoconus, at the Contact Lens Section of UNIFESP and private clinics. Keratoconus was classified according to degrees of disease severity by keratometric pattern. Age, gender, diagnosis, keratometry, visual acuity, spherical equivalent (SE), base curve and clinical indication were recorded. Of 66 patients (80 eyes) with keratoconus the mean age was 29 years, 51.5% were men and 48.5% women. According to the groups: 15.0% were incipient, 53.7% moderate, 26.3% advanced and 5.0% were severe. The majority of the eyes of patients using contact lenses (91.25%) achieved visual acuity better than 20/40. To 88 eyes 58% were tihed with lens with spherical power (mean -5.45 diopters) and 41% with spherocylinder power (from -0.5 to -5.00 cylindrical diopters). The most frequent base curve was 7.6 in 61% of the eyes. The main reasons for this special lens fitting were due to reduced tolerance and poor fitting pattern achieved with other lenses. The special soft contact lens is useful in fitting difficult keratoconic patients by offering comfort and improving visual rehabilitation that may allow more patients to postpone the need for corneal transplant.

  9. Sacroiliac joint pain as an important element of psoriatic arthritis diagnosis.

    PubMed

    Krawczyk-Wasielewska, Agnieszka; Skorupska, Elżbieta; Samborski, Włodzimierz

    2013-04-01

    Psoriatic arthritis (PsA) is a chronic inflammatory disease characterized by the coexistence of arthritis with psoriasis of the skin and nails. The sacroiliac joints were observed in 34-78% of patients with psoriatic arthritis. Due to such a high prevalence of SIJ dysfunction, understanding pathophysiology of pain and the associated pain pattern becomes a very important aspect of PsA diagnosis. As far as the etiology of SI joint dysfunction is concerned, it has not been disambiguated yet. Among the main causative factors, injuries and strains of the structures surrounding the joint are noted. Joint pathology usually manifests itself by pain occurring within the area of the joint. The causes of pain may be divided into two categories: intra-articular and extra-articular. Pain caused by the SI joint may be nociceptive or neural in nature, whereas the pain pattern characteristic of the joint correlates with its innervation and is consistent with S2 dorsal rami.

  10. Sacroiliac joint pain as an important element of psoriatic arthritis diagnosis

    PubMed Central

    Skorupska, Elżbieta; Samborski, Włodzimierz

    2013-01-01

    Psoriatic arthritis (PsA) is a chronic inflammatory disease characterized by the coexistence of arthritis with psoriasis of the skin and nails. The sacroiliac joints were observed in 34-78% of patients with psoriatic arthritis. Due to such a high prevalence of SIJ dysfunction, understanding pathophysiology of pain and the associated pain pattern becomes a very important aspect of PsA diagnosis. As far as the etiology of SI joint dysfunction is concerned, it has not been disambiguated yet. Among the main causative factors, injuries and strains of the structures surrounding the joint are noted. Joint pathology usually manifests itself by pain occurring within the area of the joint. The causes of pain may be divided into two categories: intra-articular and extra-articular. Pain caused by the SI joint may be nociceptive or neural in nature, whereas the pain pattern characteristic of the joint correlates with its innervation and is consistent with S2 dorsal rami. PMID:24278057

  11. Multicomponent Droplet Evaporation on Chemical Micro-Patterned Surfaces

    PubMed Central

    He, Minghao; Liao, Dong; Qiu, Huihe

    2017-01-01

    The evaporation and dynamics of a multicomponent droplet on a heated chemical patterned surface were presented. Comparing to the evaporation process of a multicomponent droplet on a homogenous surface, it is found that the chemical patterned surface can not only enhance evaporation by elongating the contact line, but also change the evaporation process from three regimes for the homogenous surface including constant contact line (CCL) regime, constant contact angle (CCA) regime and mix mode (MM) to two regimes, i.e. constant contact line (CCL) and moving contact line (MCL) regimes. The mechanism of contact line stepwise movement in MCL regimes in the microscopic range is investigated in detail. In addition, an improved local force model on the contact line was employed for analyzing the critical receding contact angles on homogenous and patterned surfaces. The analysis results agree well for both surfaces, and confirm that the transition from CCL to MCL regimes indicated droplet composition changes from multicomponent to monocomponent, providing an important metric to predict and control the dynamic behavior and composition of a multicomponent droplet using a patterned surface. PMID:28157229

  12. Gender differences exist in the hip joint moments of healthy older walkers.

    PubMed

    Boyer, Katherine A; Beaupre, Gary S; Andriacchi, Thomas P

    2008-12-05

    Gender differences in the incidence of symptomatic hip osteoarthritis (OA), changes in hip cartilage volume and hip joint space and rates hip arthroplasty of older people are reported in the literature. As the rate of progression of OA is in part mechanically modulated it is possible that this gender bias may be related to inherent differences (if they exist) in walking mechanics between older males and females. The purpose of this study was to examine potential mechanisms for gender differences in hip joint mechanics during walking by testing the hypotheses that females would exhibit higher hip flexion, adduction and internal rotation moments but not significantly greater normalized ground reaction forces (GRFs). Forty-two healthy subjects (21 male, 21 female), ages 50-79yr were recruited for gait analysis. In support of the hypotheses, greater external hip adduction and internal rotation along with hip extension moments were found for females compared to males after normalizing for body size for all self-selected walking speeds. Differences in walking style (kinematics) were the main determinants in the joint kinetic differences as no differences in the normalized GRFs were found. As external joint moments are surrogate measures of the joint contact forces, the results of this study suggest the hip joint stress for the female population is higher compared to male population. This is in favor of a hypothesis that the increased joint contact stress in a female population could contribute to a greater joint degeneration at the hip in females as compared with males.

  13. The effects of progressive lateralization of the joint center of rotation of reverse total shoulder implants.

    PubMed

    Costantini, Oren; Choi, Daniel S; Kontaxis, Andreas; Gulotta, Lawrence V

    2015-07-01

    There has been a renewed interest in lateralizing the center of rotation (CoR) in implants used in reverse shoulder arthroplasty. The aim of this study was to determine the sensitivity of lateralization of the CoR on the glenohumeral joint contact forces, muscle moment arms, torque across the bone-implant interface, and the stability of the implant. A 3-dimensional virtual model was used to investigate how lateralization affects deltoid muscle moment arm and glenohumeral joint contact forces. This model was virtually implanted with 5 progressively lateralized reverse shoulder prostheses. The joint contact loads and deltoid moment arms were calculated for each lateralization over the course of 3 simulated standard humerothoracic motions. Lateralization of the CoR leads to an increase in the overall joint contact forces across the glenosphere. Most of this increased loading occurred through compression, although increases in anterior/posterior and superior/inferior shear were also observed. Moment arms of the deltoid consistently decreased with lateralization. Bending moments at the implant interface increased with lateralization. Progressive lateralization resulted in improved stability ratios. Lateralization results in increased joint loading. Most of that loading occurs through compression, although there were also increases in shear forces. Anterior/posterior shear is currently not accounted for in implant fixation studies, leaving its effect on implant fixation unknown. Future studies should incorporate shear forces into their models to more accurately assess fixation methods. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. On the Role of the Patella, ACL and Joint Contact Forces in the Extension of the Knee

    PubMed Central

    Cleather, Daniel J.; Southgate, Dominic F. L.; Bull, Anthony M. J.

    2014-01-01

    Traditional descriptions of the knee suggest that the function of the patella is to facilitate knee extension by increasing the moment arm of the quadriceps muscles. Through modelling and evidence from the literature it is shown in this paper that the presence of the patella makes the ability of the quadriceps to rotate the thigh greater than their ability to rotate the tibia. Furthermore, this difference increases as the knee is flexed, thus demonstrating a pattern that is consistent with many human movements. This paper also shows that the anterior cruciate ligament plays a previously unheralded role in extending the shank and that translation at the tibiofemoral and patellofemoral joints is important in improving the capacity for thigh rotation when the knee is flexed. This study provides new insights as to how the structure of the knee is adapted to its purpose and illustrates how the functional anatomy of the knee contributes to its extension function. PMID:25536067

  15. Flow visualization of a non-contact transport device by Coanda effect

    NASA Astrophysics Data System (ADS)

    Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi

    2014-08-01

    AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.

  16. Joint Coordination and Muscle Activities of Ballet Dancers During Tiptoe Standing.

    PubMed

    Tanabe, Hiroko; Fujii, Keisuke; Kouzaki, Motoki

    2017-01-01

    We aimed to investigate joint coordination of lower limbs in dancers during tiptoe standing and the relationship between joint coordination and muscle coactivation. Seven female ballet dancers performed tiptoe standing with six leg positions (fi e classical dance positions and one modern dance position) for 10 s. The kinematic data of the metatarsophalangeal (MP), ankle, knee, and hip joints was collected, and surface electromyography (EMG) of over 13 lower limb muscles was conducted. Principal component analysis was performed to determine joint coordination. MP-ankle and ankle-knee had in-phase coordination, whereas knee-hip showed anti-phase coordination in the sagittal plane. In addition, most EMG-EMG coherence around the MP and ankle joints was significant up to 50 Hz when these two joints swayed with in-phase. This suggests that different joint coordination patterns are associated with neural processing related to different muscle coactivation patterns. In conclusion, ballet dancers showed in-phase coordination from the MP to knee joints, which was associated with muscle coactivation to a higher frequency domain (up to 50 Hz) in comparison with anti-phase coordination.

  17. Foot strike patterns and ground contact times during high-calibre middle-distance races.

    PubMed

    Hayes, Phil; Caplan, Nicholas

    2012-01-01

    The aims of this study were to examine ground contact characteristics, their relationship with race performance, and the time course of any changes in ground contact time during competitive 800 m and 1500 m races. Twenty-two seeded, single-sex middle-distance races totalling 181 runners were filmed at a competitive athletics meeting. Races were filmed at 100 Hz. Ground contact time was recorded one step for each athlete, on each lap of their race. Forefoot and midfoot strikers had significantly shorter ground contact times than heel strikers. Forefoot and midfoot strikers had significantly faster average race speed than heel strikers. There were strong large correlations between ground contact time and average race speed for the women's events and men's 1500 m (r = -0.521 to -0.623; P < 0.05), whereas the men's 800 m displayed only a moderate relationship (r = -0.361; P = 0.002). For each event, ground contact time for the first lap was significantly shorter than for the last lap, which might reflect runners becoming fatigued.

  18. Effect of the sagittal ankle angle at initial contact on energy dissipation in the lower extremity joints during a single-leg landing.

    PubMed

    Lee, Jinkyu; Song, Yongnam; Shin, Choongsoo S

    2018-05-01

    During landing, the ankle angle at initial contact (IC) exhibits relatively wide individual variation compared to the knee and hip angles. However, little is known about the effect of different IC ankle angles on energy dissipation. The purpose of this study was to investigate the relationship between individual ankle angles at IC and energy dissipation in the lower extremity joints. Twenty-seven adults performed single-leg landings from a 0.3-m height. Kinetics and kinematics of the lower extremity joints were measured. The relationship between ankle angles at IC and negative work, range of motion, the time to peak ground reaction force, and peak loading rate were analyzed. The ankle angle at IC was positively correlated with ankle negative work (r = 0.80, R 2  = 0.64, p < 0.001) and the contribution of the ankle to total (ankle, knee and hip joint) negative work (r = 0.84, R 2  = 0.70, p < 0.001), but the ankle angle was negatively correlated with hip negative work (r = -0.46, R 2  = 0.21, p = 0.01) and the contribution of the hip to total negative work (r = -0.61, R 2  = 0.37, p < 0.001). The knee negative work and the contribution of the knee to total negative work were not correlated with the ankle angle at IC. The ankle angle at IC was positively correlated with total negative work (r = 0.50, R 2  = 0.25, p < 0.01) and negatively correlated with the peak loading rate (r = -0.76, R 2  = 0.57, p < 0.001). These results indicated that landing mechanics changed as the ankle angle at IC increased, such that the ankle energy dissipation increased and redistributed the energy dissipation in the ankle and hip joints. Further, these results suggest that increased ankle energy dissipation with a higher IC plantar flexion angle may be a potential landing technique for reducing the risk of injury to the anterior cruciate ligament and hip musculature. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. ASL or Contact Signing: Issues of Judgment.

    ERIC Educational Resources Information Center

    Lucas, Ceil; Valli, Clayton

    1991-01-01

    Reports on one aspect of an ongoing study of language contact in the American deaf community. The ultimate goal of the study is a linguistic description of contact signing and a reexamination of claims that it is a pidgin. Patterns of language use are reviewed and the role of demographic information in judgments is examined. (29 references) (GLR)

  20. Pattern of maxillary and mandibular proximal enamel thickness at the contact area of the permanent dentition from first molar to first molar.

    PubMed

    Sarig, Rachel; Vardimon, Alexander D; Sussan, Celine; Benny, Lea; Sarne, Ofer; Hershkovitz, Israel; Shpack, Nir

    2015-04-01

    Proximal enamel thickness (PET) at the mesial and distal contact areas of the complete permanent dentition has not been previously reported. Anatomic investigation of PET is essential for interproximal reduction treatment. Our objectives were to measure the PETs of the complete maxillary and mandibular dentitions at the contact areas, to compare the PETs of adjacent teeth, and to evaluate the vertical position of each contact area. We evaluated 720 extracted teeth; of these, 109 intact teeth were selected. The mesial and distal contact areas were demarcated, and each tooth was embedded in transparent epoxy resin. Blocks were prepared so that the 2 demarcated contact areas were exposed, and 6 measurements were taken and statistically analyzed. Both jaws showed the same PET pattern characterized by 5 features: PET increased progressively from incisor (0.63 mm) to first molar (1.48 mm). Per tooth, mesial and distal PET did not differ. Total maxillary (26.86 mm) and mandibular (24.52 mm) PETs were similar. Paired PETs at the interproximal interface were similar, with the exception of the lateral incisor-canine interfaces. From incisor to first molar, the contact area becomes located farther gingivally. The existing guideline of maximal 0.5-mm interproximal reduction per 2 adjacent teeth should be kept in the anterior region and could be increased to 1 mm in the posterior region, when an equal amount is removed. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Joint Chiefs of Staff > Directorates > Directorates of Management

    Science.gov Websites

    establishes information management requirements and manages the corporate Joint Staff decision process to Force Chief of Staff Chief of National Guard Bureau Biographies Directorates Directorates of Management J8 | Force Structure, Resources & Assessment Contact Directorate of Management Home

  2. Dynamic analysis of clamp band joint system subjected to axial vibration

    NASA Astrophysics Data System (ADS)

    Qin, Z. Y.; Yan, S. Z.; Chu, F. L.

    2010-10-01

    Clamp band joints are commonly used for connecting circular components together in industry. Some of the systems jointed by clamp band are subjected to dynamic load. However, very little research on the dynamic characteristics for this kind of joint can be found in the literature. In this paper, a dynamic model for clamp band joint system is developed. Contact and frictional slip between the components are accommodated in this model. Nonlinear finite element analysis is conducted to identify the model parameters. Then static experiments are carried out on a scaled model of the clamp band joint to validate the joint model. Finally, the model is adopted to study the dynamic characteristics of the clamp band joint system subjected to axial harmonic excitation and the effects of the wedge angle of the clamp band joint and the preload on the response. The model proposed in this paper can represent the nonlinearity of the clamp band joint and be used conveniently to investigate the effects of the structural and loading parameters on the dynamic characteristics of this type of joint system.

  3. Joint Angular Velocity in Spastic Gait and the Influence of Muscle-Tendon Lengthening*

    PubMed Central

    GRANATA, KEVIN P.; ABEL, MARK F.; DAMIANO, DIANE L.

    2006-01-01

    Background Joint angular velocity (the rate of flexion and extension of a joint) is related to the dynamics of muscle activation and force generation during walking. Therefore, the goal of this research was to examine the joint angular velocity in normal and spastic gait and changes resulting from muscle-tendon lengthening (recession and tenotomy) in patients who have spastic cerebral palsy. Methods The gait patterns of forty patients who had been diagnosed with spastic cerebral palsy (mean age, 8.3 years; range, 3.7 to 14.8 years) and of seventy-three age-matched, normally developing subjects were evaluated with three-dimensional motion analysis and electromyography. The patients who had cerebral palsy were evaluated before muscle-tendon lengthening and nine months after treatment. Results The gait patterns of the patients who had cerebral palsy were characterized by increased flexion of the knee in the stance phase, premature plantar flexion of the ankle, and reduced joint angular velocities compared with the patterns of the normally developing subjects. Even though muscle-tendon lengthening altered sagittal joint angles in gait, the joint angular velocities were generally unchanged at the hip and knee. Only the ankle demonstrated modified angular velocities, including reduced dorsiflexion velocity at foot-strike and improved dorsiflexion velocity through midstance, after treatment. Electromyographic changes included reduced amplitude of the gastrocnemius-soleus during the loading phase and decreased knee coactivity (the ratio of quadriceps and hamstring activation) at toe-off. Principal component analyses showed that, compared with joint-angle data, joint angular velocity was better able to discriminate between the gait patterns of the normal and cerebral palsy groups. Conclusions This study showed that muscle-tendon lengthening corrects biomechanical alignment as reflected by changes in sagittal joint angles. However, joint angular velocity and

  4. Prediction of hip joint load and translation using musculoskeletal modelling with force-dependent kinematics and experimental validation.

    PubMed

    Zhang, Xuan; Chen, Zhenxian; Wang, Ling; Yang, Wenjian; Li, Dichen; Jin, Zhongmin

    2015-07-01

    Musculoskeletal lower limb models are widely used to predict the resultant contact force in the hip joint as a non-invasive alternative to instrumented implants. Previous musculoskeletal models based on rigid body assumptions treated the hip joint as an ideal sphere with only three rotational degrees of freedom. An musculoskeletal model that considered force-dependent kinematics with three additional translational degrees of freedom was developed and validated in this study by comparing it with a previous experimental measurement. A 32-mm femoral head against a polyethylene cup was considered in the musculoskeletal model for calculating the contact forces. The changes in the main modelling parameters were found to have little influence on the hip joint forces (relative deviation of peak value < 10 BW%, mean trial deviation < 20 BW%). The centre of the hip joint translation was more sensitive to the changes in the main modelling parameters, especially muscle recruitment type (relative deviation of peak value < 20%, mean trial deviation < 0.02 mm). The predicted hip contact forces showed consistent profiles, compared with the experimental measurements, except in the lateral-medial direction. The ratio-average analysis, based on the Bland-Altman's plots, showed better limits of agreement in climbing stairs (mean limits of agreement: -2.0 to 6.3 in walking, mean limits of agreement: -0.5 to 3.1 in climbing stairs). Better agreement of the predicted hip contact forces was also found during the stance phase. The force-dependent kinematics approach underestimated the maximum hip contact force by a mean value of 6.68 ± 1.75% BW compared with the experimental measurements. The predicted maximum translations of the hip joint centres were 0.125 ± 0.03 mm in level walking and 0.123 ± 0.005 mm in climbing stairs. © IMechE 2015.

  5. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    PubMed

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  6. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    PubMed Central

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  7. Structure of welded joints obtained by contact weld in nanostructured titanium

    NASA Astrophysics Data System (ADS)

    Klimenov, V. A.; Klopotov, A. A.; Gnysov, S. F.; Vlasov, V. A.; Lychagin, D. V.; Chumaevskii, A. V.

    2015-10-01

    The paper presents the research of the weld structure of two Ti specimens of the type VT6 that have nano- and submicrocrystalline structures. Electrical contact welding is used to obtain welds. The acicular structure is formed in the weld area. Two types of defects are detected, namely micropores and microcracks.

  8. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    NASA Astrophysics Data System (ADS)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  9. Is midsole thickness a key parameter for the running pattern?

    PubMed

    Chambon, Nicolas; Delattre, Nicolas; Guéguen, Nils; Berton, Eric; Rao, Guillaume

    2014-01-01

    Many studies have highlighted differences in foot strike pattern comparing habitually shod runners who ran barefoot and with running shoes. Barefoot running results in a flatter foot landing and in a decreased vertical ground reaction force compared to shod running. The aim of this study was to investigate one possible parameter influencing running pattern: the midsole thickness. Fifteen participants ran overground at 3.3 ms(-1) barefoot and with five shoes of different midsole thickness (0 mm, 2 mm, 4 mm, 8 mm, 16 mm) with no difference of height between rearfoot and forefoot. Impact magnitude was evaluated using transient peak of vertical ground reaction force, loading rate, tibial acceleration peak and rate. Hip, knee and ankle flexion angles were computed at touch-down and during stance phase (range of motion and maximum values). External net joint moments and stiffness for hip, knee and ankle joints were also observed as well as global leg stiffness. No significant effect of midsole thickness was observed on ground reaction force and tibial acceleration. However, the contact time increased with midsole thickness. Barefoot running compared to shod running induced ankle in plantar flexion at touch-down, higher ankle dorsiflexion and lower knee flexion during stance phase. These adjustments are suspected to explain the absence of difference on ground reaction force and tibial acceleration. This study showed that the presence of very thin footwear upper and sole was sufficient to significantly influence the running pattern. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Fragrance contact dermatitis in Korea: a joint study.

    PubMed

    An, Susun; Lee, Ai-Young; Lee, Cheol Heon; Kim, Do-Won; Hahm, Jeong Hee; Kim, Kea-Jeung; Moon, Kee-Chan; Won, Young Ho; Ro, Young-Suck; Eun, Hee Chul

    2005-12-01

    The purpose of this study is to determine the frequency of responses to selected fragrances in patients with suspected fragrance allergy and to evaluate the risk factors. 9 dermatology departments of university hospitals have participated in this study for the past 1 year. To determine allergic response to fragrances, 18 additional fragrances in addition to the Korean standard and a commercial fragrance series were patch-tested in patients with suspecting cosmetic contact dermatitis. Over 80% of the patients were women, and the most common site was the face. Cinnamic alcohol and sandalwood oil (Santalum album L.) showed high frequencies of positive responses. Of the specific fragrances, ebanol, alpha-isomethyl-ionone (methyl ionone-gamma) and Lyral (hydroxyisohexyl 3-cyclohexane carboxdaldehyde) showed high positive responses. We compared the results obtained during this study with those of other studies and concluded that including additional fragrance allergens may be useful for the detection of fragrance allergy.

  11. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation

    PubMed Central

    Muñoz-Romero, Sergio; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; García-Alberola, Arcadi

    2018-01-01

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  12. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    PubMed

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends

  13. Techniques for Solution- Assisted Optical Contacting

    NASA Technical Reports Server (NTRS)

    DeVine, Glenn; Ware, Brent; Wuchenich, Danielle M.; Spero, Robert E.; Klipstein, William M.; McKenzie, Kirk

    2012-01-01

    A document discusses a solution-assisted contacting technique for optical contacting. An optic of surface flatness Lambda/20 was successfully contacted with one of moderate surface quality, or Lambda/4. Optics used were both ultra-low expansion (ULE) glass (Lambda/4 and Lambda/20) and fused silica (Lambda/20). A stainless steel template of the intended interferometer layout was designed and constructed with three contact points per optic. The contact points were all on a common side of the template. The entire contacting jig was tilted at about 30 . Thus, when the isopropanol was applied, each optic slid due to gravity, resting on the contact points. All of the contacting was performed in a relatively dusty laboratory. A number of successful contacts were achieved where up to two or three visible pieces of dust could be seen. These were clearly visible due to refraction patterns between the optic and bench. On a number of optics, the final step of dropping isopropyl between the surfaces was repeated until a successful contact was achieved. The new procedures realized in this work represent a simplification for optical contacting in the laboratory. They will both save time and money spent during the contacting process, and research and development phases. The techniques outlined are suitable for laboratory experiments, research, and initial development stages.

  14. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    PubMed

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. ``Coffee-ring'' patterns of polymer droplets

    NASA Astrophysics Data System (ADS)

    Biswas, Nupur; Datta, Alokmay

    2013-02-01

    Dried droplets of polymer solutions carries the self-assembly behavior of polymer molecules by forming various patterns. Pattern formation is a consequence of deposition of molecules depending on motion of the contact line during the drying process. The contact line motion depends on initial polymer concentrations and hence entanglement. Thus depending on entanglement the patterns represent the `particle' like or `collective' behavior of polymer molecules.

  16. Comparison of various contact algorithms for poroelastic tissues.

    PubMed

    Galbusera, Fabio; Bashkuev, Maxim; Wilke, Hans-Joachim; Shirazi-Adl, Aboulfazl; Schmidt, Hendrik

    2014-01-01

    Capabilities of the commercial finite element package ABAQUS in simulating frictionless contact between two saturated porous structures were evaluated and compared with those of an open source code, FEBio. In ABAQUS, both the default contact implementation and another algorithm based on an iterative approach requiring script programming were considered. Test simulations included a patch test of two cylindrical slabs in a gapless contact and confined compression conditions; a confined compression test of a porous cylindrical slab with a spherical porous indenter; and finally two unconfined compression tests of soft tissues mimicking diarthrodial joints. The patch test showed almost identical results for all algorithms. On the contrary, the confined and unconfined compression tests demonstrated large differences related to distinct physical and boundary conditions considered in each of the three contact algorithms investigated in this study. In general, contact with non-uniform gaps between fluid-filled porous structures could be effectively simulated with either ABAQUS or FEBio. The user should be aware of the parameter definitions, assumptions and limitations in each case, and take into consideration the physics and boundary conditions of the problem of interest when searching for the most appropriate model.

  17. Bolted joints in graphite-epoxy composites

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1976-01-01

    All-graphite/epoxy laminates and hybrid graphite-glass/epoxy laminates were tested. The tests encompassed a range of geometries for each laminate pattern to cover the three basic failure modes - net section tension failure through the bolt hole, bearing and shearout. Static tensile and compressive loads were applied. A constant bolt diameter of 6.35 mm (0.25 in.) was used in the tests. The interaction of stress concentrations associated with multi-row bolted joints was investigated by testing single- and double-row bolted joints and open-hole specimens in tension. For tension loading, linear interaction was found to exist between the bearing stress reacted at a given bolt hole and the remaining tension stress running by that hole to be reacted elsewhere. The interaction under compressive loading was found to be non-linear. Comparative tests were run using single-lap bolted joints and double-lap joints with pin connection. Both of these joint types exhibited lower strengths than were demonstrated by the corresponding double-lap joints. The analysis methods developed here for single bolt joints are shown to be capable of predicting the behavior of multi-row joints.

  18. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury.

    PubMed

    Wellsandt, Elizabeth; Gardinier, Emily S; Manal, Kurt; Axe, Michael J; Buchanan, Thomas S; Snyder-Mackler, Lynn

    2016-01-01

    Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Case-control study; Level of evidence, 3. Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs -0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: -0.001 ± 0.032 N·m·s/kg·m [nonOA] vs -0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs -0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak medial compartment contact forces of the involved limb

  19. Decreased Knee Joint Loading Associated With Early Knee Osteoarthritis After Anterior Cruciate Ligament Injury

    PubMed Central

    Wellsandt, Elizabeth; Gardinier, Emily S.; Manal, Kurt; Axe, Michael J.; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background Anterior cruciate ligament (ACL) injury predisposes individuals to early-onset knee joint osteoarthritis (OA). Abnormal joint loading is apparent after ACL injury and reconstruction. The relationship between altered joint biomechanics and the development of knee OA is unknown. Hypothesis Altered knee joint kinetics and medial compartment contact forces initially after injury and reconstruction are associated with radiographic knee OA 5 years after reconstruction. Study Design Case-control study; Level of evidence, 3. Methods Individuals with acute, unilateral ACL injury completed gait analysis before (baseline) and after (posttraining) preoperative rehabilitation and at 6 months, 1 year, and 2 years after reconstruction. Surface electromyographic and knee biomechanical data served as inputs to an electromyographically driven musculoskeletal model to estimate knee joint contact forces. Patients completed radiographic testing 5 years after reconstruction. Differences in knee joint kinetics and contact forces were compared between patients with and those without radiographic knee OA. Results Patients with OA walked with greater frontal plane interlimb differences than those without OA (nonOA) at baseline (peak knee adduction moment difference: 0.00 ± 0.08 N·m/kg·m [nonOA] vs −0.15 ± 0.09 N·m/kg·m [OA], P = .014; peak knee adduction moment impulse difference: −0.001 ± 0.032 N·m·s/kg·m [nonOA] vs −0.048 ± 0.031 N·m·s/kg·m [OA], P = .042). The involved limb knee adduction moment impulse of the group with osteoarthritis was also lower than that of the group without osteoarthritis at baseline (0.087 ± 0.023 N·m·s/kg·m [nonOA] vs 0.049 ± 0.018 N·m·s/kg·m [OA], P = .023). Significant group differences were absent at posttraining but reemerged 6 months after reconstruction (peak knee adduction moment difference: 0.02 ± 0.04 N·m/kg·m [nonOA] vs −0.06 ± 0.11 N·m/kg·m [OA], P = .043). In addition, the OA group walked with lower peak

  20. Subperiosteal Transmission Of Intra-Articular Pressure Between Articulated And Stationary Joints

    PubMed Central

    Pitkin, Mark; Muppavarapu, Raghuveer; Cassidy, Charles; Pitkin, Emil

    2015-01-01

    Hydrostatic pressures can be transmitted between synovial capsules. In each of ten rabbits, we simultaneously measured pressure in two joints, one of which was passively ranged, and the other of which was kept stationary. The intra-articular pressure inside the stationary joint changed every time its companion joint was ranged. But the pressure in the stationary joint did not change when the periosteum was transected above the ranged joint. This phenomenon was observed in all four animals that served as their own controls. The study suggests that the intra-articular pressure was transmitted through the space between the periosteum and the bone surface. Alternative explanations, like measurements of venous blood pressure, did not show correlation with hydrostatic pressure changes in the joints. The Floating Skeleton concept suggests a biomechanical rationale for this newly observed phenomenon: that there exists a subperiosteal hydrostatic connection of synovial joints, and that this “net” distributes excess pressures among joints through the periosteal sheath to sustain the integrity of the joint contacting surfaces over a lifetime. PMID:25632015

  1. Pattern Laser Annealing by a Pulsed Laser

    NASA Astrophysics Data System (ADS)

    Komiya, Yoshio; Hoh, Koichiro; Murakami, Koichi; Takahashi, Tetsuo; Tarui, Yasuo

    1981-10-01

    Preliminary experiments with contact-type pattern laser annealing were made for local polycrystallization of a-Si, local evaporation of a-Si and local formation of Ni-Si alloy. These experiments showed that the mask patterns can be replicated as annealed regions with a resolution of a few microns on substrates. To overcome shortcomings due to the contact type pattern annealing, a projection type reduction pattern laser annealing system is proposed for resistless low temperature pattern forming processes.

  2. Contact control for advanced applications of light weight arms

    NASA Technical Reports Server (NTRS)

    Book, Wayne J.; Kwon, Dong-Soo

    1991-01-01

    Many applications of robotic and teleoperated manipulator arms require operation in contact and non-contact regimes. This paper deals with both regimes and the transition between them with special attention given to problems of flexibility in the links and drives. This is referred to as contact control. Inverse dynamics is used to plan the tip motion of the flexible link so that the free motion can stop very near the contact surface without collision due to overshoot. Contact must occur at a very low speed since the high frequency impact forces are too sudden to be affected by any feedback generated torques applied to a joint at the other end of the link. The effect of approach velocity and surface properties are discussed. Force tracking is implemented by commands to the deflection states of the link and the contact force. This enables a natural transition between tip position and tip force control that is not possible when the arm is treated as rigid. The effect of feedback gain, force trajectory, and desired final force are of particular interest and are studied. Experimental results are presented on a one link arm and the system performance in the overall contact task is analyzed. Extension to multi-link cases with potential applications are discussed.

  3. MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

    PubMed

    Fischer, Kenneth J; Johnson, Joshua E; Waller, Alexander J; McIff, Terence E; Toby, E Bruce; Bilgen, Mehmet

    2011-10-01

    The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations

  4. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: Implications for preclinical testing.

    PubMed

    Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D

    2014-08-01

    Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.

  5. Joint imaging in polymyalgia rheumatica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Duffy, J.D.; Wahner, H.W.; Hunder, G.G.

    1976-08-01

    Technetium pertechnetate joint scintigrams were abnormal in 24 of 25 patients with polymyalgia rheumatica, in all 16 with rheumatoid arthritis, in 4 of 13 with nonarticular rheumatism, but in none of 26 control patients. Abnormal uptake in polymyalgia patients was commonest in shoulders and was less likely to be symmetric than in patients with rheumatoid arthritis, in whom distal joint abnormalities predominated. The pattern of abnormal uptake in polymyalgia rheumatica was not different in those with biopsy-proved giant cell arteritis. Correlation between symptoms and abnormal scintigrams was 72%, and abnormal uptake was present in 81% of joints of patients havingmore » physical abnormalities. Biopsy showed lymphocytic synovitis in the knee of one patient. After treatment the number of abnormal joints declined. These findings suggest that synovitis is common in polymyalgia rheumatica, and that it may account for some or most of the symptoms in this condition.« less

  6. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    NASA Astrophysics Data System (ADS)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  7. Joint attention revisited: Finding strengths among children with autism.

    PubMed

    Hurwitz, Sarah; Watson, Linda R

    2016-07-01

    Differences in joint attention are prominent for some children with autism and are often used as an indicator of the disorder. This study examined the joint attention competencies of young children with autism who demonstrated joint attention ability and compared them to children with developmental delays. A total of 40 children with autism and developmental delays were matched pairwise based on mental and chronological age. Videos of children engaging in play were coded for the frequency and forms (eye contact, gestures, affect, etc.) of joint attention. Additionally, concurrent language was compared among children with autism (N = 32) by their joint attention ability. Children with autism spectrum disorder entered into joint attention significantly less often than children with developmental delays, but once engaged used the forms of joint attention similarly. For the matched pairs, there were no differences in language, but the children with autism who used joint attention had significantly better language than children with autism who did not (even after controlling for mental age). There is a group of young children with autism who can use joint attention but do so at lower frequencies than children with developmental delays. Possible reasons include difficulty disengaging attention and limited intrinsic social motivation to share. Adult persistence is recommended to encourage joint attention. © The Author(s) 2015.

  8. A Cervico-Thoraco-Lumbar Multibody Dynamic Model for the Estimation of Joint Loads and Muscle Forces.

    PubMed

    Khurelbaatar, Tsolmonbaatar; Kim, Kyungsoo; Hyuk Kim, Yoon

    2015-11-01

    Computational musculoskeletal models have been developed to predict mechanical joint loads on the human spine, such as the forces and moments applied to vertebral and facet joints and the forces that act on ligaments and muscles because of difficulties in the direct measurement of joint loads. However, many whole-spine models lack certain elements. For example, the detailed facet joints in the cervical region or the whole spine region may not be implemented. In this study, a detailed cervico-thoraco-lumbar multibody musculoskeletal model with all major ligaments, separated structures of facet contact and intervertebral disk joints, and the rib cage was developed. The model was validated by comparing the intersegmental rotations, ligament tensile forces, facet joint contact forces, compressive and shear forces on disks, and muscle forces were to those reported in previous experimental and computational studies both by region (cervical, thoracic, or lumbar regions) and for the whole model. The comparisons demonstrated that our whole spine model is consistent with in vitro and in vivo experimental studies and with computational studies. The model developed in this study can be used in further studies to better understand spine structures and injury mechanisms of spinal disorders.

  9. Finite element based contact analysis of radio frequency MEMs switch membrane surfaces

    NASA Astrophysics Data System (ADS)

    Liu, Jin-Ya; Chalivendra, Vijaya; Huang, Wenzhen

    2017-10-01

    Finite element simulations were performed to determine the contact behavior of radio frequency (RF) micro-electro-mechanical (MEM) switch contact surfaces under monotonic and cyclic loading conditions. Atomic force microscopy (AFM) was used to capture the topography of RF-MEM switch membranes and later they were analyzed for multi-scale regular as well as fractal structures. Frictionless, non-adhesive contact 3D finite element analysis was carried out at different length scales to investigate the contact behavior of the regular-fractal surface using an elasto-plastic material model. Dominant micro-scale regular patterns were found to significantly change the contact behavior. Contact areas mainly cluster around the regular pattern. The contribution from the fractal structure is not significant. Under cyclic loading conditions, plastic deformation in the 1st loading/unloading cycle smooth the surface. The subsequent repetitive loading/unloading cycles undergo elastic contact without changing the morphology of the contacting surfaces. The work is expected to shed light on the quality of the switch surface contact as well as the optimum design of RF MEM switch surfaces.

  10. Predicting the Functional Roles of Knee Joint Muscles from Internal Joint Moments.

    PubMed

    Flaxman, Teresa E; Alkjær, Tine; Simonsen, Erik B; Krogsgaard, Michael R; Benoit, Daniel L

    2017-03-01

    Knee muscles are commonly labeled as flexors or extensors and aptly stabilize the knee against sagittal plane loads. However, how these muscles stabilize the knee against adduction-abduction and rotational loads remains unclear. Our study sought 1) to classify muscle roles as they relate to joint stability by quantifying the relationship between individual muscle activation patterns and internal net joint moments in all three loading planes and 2) to determine whether these roles change with increasing force levels. A standing isometric force matching protocol required subjects to modulate ground reaction forces to elicit various combinations and magnitudes of sagittal, frontal, and transverse internal joint moments. Surface EMG measured activities of 10 lower limb muscles. Partial least squares regressions determined which internal moment(s) were significantly related to the activation of individual muscles. Rectus femoris and tensor fasciae latae were classified as moment actuators for knee extension and hip flexion. Hamstrings were classified as moment actuators for hip extension and knee flexion. Gastrocnemius and hamstring muscles were classified as specific joint stabilizers for knee rotation. Vastii were classified as general joint stabilizers because activation was independent of moment generation. Muscle roles did not change with increasing effort levels. Our findings indicate muscle activation is not dependent on anatomical orientation but perhaps on its role in maintaining knee joint stability in the frontal and transverse loading planes. This is useful for delineating the roles of biarticular knee joint muscles and could have implications in robotics, musculoskeletal modeling, sports sciences, and rehabilitation.

  11. Effects of oxidation and roughness on Cu contact resistance from 4 to 290 K

    NASA Technical Reports Server (NTRS)

    Nilles, M. J.; Van Sciver, S. W.

    1988-01-01

    Knowledge of the factors influencing contact resistance is important for optimizing system design in cryogenic applications. In space cryogenics, indirect cooling of infrared components is the primary concern. The presence of bolted joints results in contact resistances which can dominate all other contributions to the overall heat transfer rate. Here, thermal and electrical contact resistances measured between 4 K and 290 K for a series of bolted OFHC Cu contacts are reported. Surface roughness is found to have little effect on the overall contact resistance within the experimental limits, while oxidation can increase the contact resistance by as much as a factor of 100. Thermal and electrical contact resistances measured on the same contact show that the contact resistance temperature dependence does not follow the bulk dependence. For example, the residual resistance ratio (RRR) of the OFHC Cu is 110, but for contacts made from this material, the RRR is about two.

  12. Influence of Step Rate and Quadriceps Load Distribution on Patellofemoral Cartilage Contact Pressures during Running

    PubMed Central

    Lenhart, Rachel L.; Smith, Colin R.; Vignos, Michael F.; Kaiser, Jarred; Heiderscheit, Bryan C.; Thelen, Darryl G.

    2015-01-01

    Interventions used to treat patellofemoral pain in runners are often designed to alter patellofemoral mechanics. This study used a computational model to investigate the influence of two interventions, step rate manipulation and quadriceps strengthening, on patellofemoral contact pressures during running. Running mechanics were analyzed using a lower extremity musculoskeletal model that included a knee with six degree-of-freedom tibiofemoral and patellofemoral joints. An elastic foundation model was used to compute articular contact pressures. The lower extremity model was scaled to anthropometric dimensions of 22 healthy adults, who ran on an instrumented treadmill at 90%, 100% and 110% of their preferred step rate. Numerical optimization was then used to predict the muscle forces, secondary tibiofemoral kinematics and all patellofemoral kinematics that would generate the measured hip, knee and ankle joint accelerations. Mean and peak patella contact pressures reached 5.0 and 9.7 MPa during the midstance phase of running. Increasing step rate by 10% significantly reduced mean contact pressures by 10.4% and contact area by 7.4%, but had small effects on lateral patella translation and tilt. Enhancing vastus medialis strength did not substantially affect pressure magnitudes or lateral patella translation, but did shift contact pressure medially toward the patellar median ridge. Thus, the model suggests that step rate tends to primarily modulate the magnitude of contact pressure and contact area, while vastus medialis strengthening has the potential to alter mediolateral pressure locations. These results are relevant to consider in the design of interventions used to prevent or treat patellofemoral pain in runners. PMID:26070646

  13. Why is joint attention a pivotal skill in autism?

    PubMed Central

    Charman, Tony

    2003-01-01

    Joint attention abilities play a crucial role in the development of autism. Impairments in joint attention are among the earliest signs of the disorder and joint attention skills relate to outcome, both in the 'natural course' of autism and through being targeted in early intervention programmes. In the current study, concurrent and longitudinal associations between joint attention and other social communication abilities measured in a sample of infants with autism and related pervasive developmental disorders at age 20 months, and language and symptom severity at age 42 months, were examined. Extending the findings from previous studies, joint attention ability was positively associated with language gains and (lower) social and communication symptoms, and imitation ability was also positively associated with later language. Some specificity in the association between different aspects of joint attention behaviours and outcome was found: declarative, triadic gaze switching predicted language and symptom severity but imperative, dyadic eye contact behaviours did not. Further, although joint attention was associated with later social and language symptoms it was unrelated to repetitive and stereotyped symptoms, suggesting the latter may have a separate developmental trajectory. Possible deficits in psychological and neurological processes that might underlie the impaired development of joint attention in autism are discussed. PMID:12639329

  14. Modulating tibiofemoral contact force in the sheep hind limb via treadmill walking: Predictions from an opensim musculoskeletal model.

    PubMed

    Lerner, Zachary F; Gadomski, Benjamin C; Ipson, Allison K; Haussler, Kevin K; Puttlitz, Christian M; Browning, Raymond C

    2015-08-01

    Sheep are a predominant animal model used to study a variety of orthopedic conditions. Understanding and controlling the in-vivo loading environment in the sheep hind limb is often necessary for investigations relating to bone and joint mechanics. The purpose of this study was to develop a musculoskeletal model of an adult sheep hind limb and investigate the effects of treadmill walking speed on muscle and joint contact forces. We constructed the skeletal geometry of the model from computed topography images. Dual-energy x-ray absorptiometry was utilized to establish the inertial properties of each model segment. Detailed dissection and tendon excursion experiments established the requisite muscle lines of actions. We used OpenSim and experimentally-collected marker trajectories and ground reaction forces to quantify muscle and joint contact forces during treadmill walking at 0.25 m• s(-1) and 0.75 m• s(-1) . Peak compressive and anterior-posterior tibiofemoral contact forces were 20% (0.38 BW, p = 0.008) and 37% (0.17 BW, p = 0.040) larger, respectively, at the moderate gait speed relative to the slower speed. Medial-lateral tibiofemoral contact forces were not significantly different. Adjusting treadmill speed appears to be a viable method to modulate compressive and anterior-posterior tibiofemoral contact forces in the sheep hind limb. The musculoskeletal model is freely-available at www.SimTK.org. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    PubMed

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  16. PATIENT-SPECIFIC FINITE ELEMENT ANALYSIS OF CHRONIC CONTACT STRESS EXPOSURE AFTER INTRA-ARTICULAR FRACTURE OF THE TIBIAL PLAFOND

    PubMed Central

    Li, Wendy; Anderson, Donald D.; Goldsworthy, Jane K.; Marsh, J. Lawrence; Brown, Thomas D.

    2008-01-01

    SUMMARY The role of altered contact mechanics in the pathogenesis of post-traumatic osteoarthritis (PTOA) following intra-articular fracture remains poorly understood. One proposed etiology is that residual incongruities lead to altered joint contact stresses that, over time, predispose to PTOA. Prevailing joint contact stresses following surgical fracture reduction were quantified in this study using patient-specific contact finite element (FE) analysis. FE models were created for 11 ankle pairs from tibial plafond fracture patients. Both (reduced) fractured ankles and their intact contralaterals were modeled. A sequence of 13 loading instances was used to simulate the stance phase of gait. Contact stresses were summed across loadings in the simulation, weighted by resident time in the gait cycle. This chronic exposure measure, a metric of degeneration propensity, was then compared between intact and fractured ankle pairs. Intact ankles had lower peak contact stress exposures that were more uniform, and centrally located. The series-average peak contact stress elevation for fractured ankles was 38% (p=0.0015; peak elevation was 82%). Fractured ankles had less area with low contact stress exposure than intacts, and a greater area with high exposure. Chronic contact stress overexposures (stresses exceeding a damage threshold) ranged from near zero to a high of 18 times the matched intact value. The patient-specific FE models utilized in this study represent substantial progress towards elucidating the relationship between altered contact stresses and the outcome of patients treated for intra-articular fractures. PMID:18404662

  17. Motion control of the rabbit ankle joint with a flat interface nerve electrode.

    PubMed

    Park, Hyun-Joo; Durand, Dominique M

    2015-12-01

    A flat interface nerve electrode (FINE) has been shown to improve fascicular and subfascicular selectivity. A recently developed novel control algorithm for FINE was applied to motion control of the rabbit ankle. A 14-contact FINE was placed on the rabbit sciatic nerve (n = 8), and ankle joint motion was controlled for sinusoidal trajectories and filtered random trajectories. To this end, a real-time controller was implemented with a multiple-channel current stimulus isolator. The performance test results showed good tracking performance of rabbit ankle joint motion for filtered random trajectories and sinusoidal trajectories (0.5 Hz and 1.0 Hz) with <10% average root-mean-square (RMS) tracking error, whereas the average range of ankle joint motion was between -20.0 ± 9.3° and 18.1 ± 8.8°. The proposed control algorithm enables the use of a multiple-contact nerve electrode for motion trajectory tracking control of musculoskeletal systems. © 2015 Wiley Periodicals, Inc.

  18. Thermal Conductances Of Metal Contacts

    NASA Technical Reports Server (NTRS)

    Salerno, L. J.; Kittel, P.; Scherkenbach, F. E.; Spivak, A. L.

    1988-01-01

    Report presents results of measurements of thermal conductances of aluminum and stainless-steel contacts at temperatures from 1.6 to 6.0 K. Measurement apparatus includes gearmotor assembly connected to rocker arm by music wire to load sample pair with forces up to 670 N. Heater placed above upper sample. Germanium resistance thermometers in upper and lower samples measured temperature difference across interface over range of heater powers from 0.1 to 10.0 mW. The thermal conductance calculated from temperature difference. Measurements provide data for prediction of thermal conductances of bolted joints in cryogenic infrared instruments.

  19. The effects of load carriage and muscle fatigue on lower-extremity joint mechanics.

    PubMed

    Wang, He; Frame, Jeff; Ozimek, Elicia; Leib, Daniel; Dugan, Eric L

    2013-09-01

    Military personnel are commonly afflicted by lower-extremity overuse injuries. Load carriage and muscular fatigue are major stressors during military basic training. To examine effects of load carriage and muscular fatigue on lower-extremity joint mechanics during walking. Eighteen men performed the following tasks: unloaded walking, walking with a 32-kg load, fatigued walking with a 32-kg load, and fatigued walking. After the second walking task, muscle fatigue was elicited through a fatiguing protocol consisting of metered step-ups and heel raises with a 16-kg load. Each walking task was performed at 1.67 m x s(-1) for 5 min. Walking movement was tracked by a VICON motion capture system at 120 Hz. Ground reaction forces were collected by a tandem force instrumented treadmill (AMTI) at 2,400 Hz. Lower-extremity joint mechanics were calculated in Visual 3D. There was no interaction between load carriage and fatigue on lower-extremity joint mechanics (p > .05). Both load carriage and fatigue led to pronounced alterations of lower-extremity joint mechanics (p < .05). Load carriage resulted in increases of pelvis anterior tilt, hip and knee flexion at heel contact, and increases of hip, knee, and ankle joint moments and powers during weight acceptance. Muscle fatigue led to decreases of ankle dorsiflexion at heel contact, dorsiflexor moment, and joint power at weight acceptance. In addition, muscle fatigue increased demand for hip extensor moment and power at weight acceptance. Statistically significant changes in lower-extremity joint mechanics during loaded and fatigued walking may expose military personnel to increased risk for overuse injuries.

  20. Effect of progressive wear on the contact mechanics of hip replacements--does the realistic surface profile matter?

    PubMed

    Wang, Ling; Yang, Wenjian; Peng, Xifeng; Li, Dichen; Dong, Shuangpeng; Zhang, Shu; Zhu, Jinyu; Jin, Zhongmin

    2015-04-13

    The contact mechanics of artificial metal-on-polyethylene hip joints are believed to affect the lubrication, wear and friction of the articulating surfaces and may lead to the joint loosening. Finite element analysis has been widely used for contact mechanics studies and good agreements have been achieved with current experimental data; however, most studies were carried out with idealist spherical geometries of the hip prostheses rather than the realistic worn surfaces, either for simplification reason or lacking of worn surface profile. In this study, the worn surfaces of the samples from various stages of hip simulator testing (0 to 5 million cycles) were reconstructed as solid models and were applied in the contact mechanics study. The simulator testing results suggested that the center of the head has various departure value from that of the cup and the value of the departure varies with progressively increased wear. This finding was adopted into the finite element study for better evaluation accuracy. Results indicated that the realistic model provided different evaluation from that of the ideal spherical model. Moreover, with the progressively increased wear, large increase of the contact pressure (from 12 to 31 MPa) was predicted on the articulating surface, and the predicted maximum von Mises stress was increased from 7.47 to 13.26 MPa, indicating the marked effect of the worn surface profiles on the contact mechanics of the joint. This study seeks to emphasize the importance of realistic worn surface profile of the acetabular cup especially following large wear volume. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Patterns in the bony skull development of marsupials: high variation in onset of ossification and conserved regions of bone contact

    PubMed Central

    Spiekman, Stephan N. F.; Werneburg, Ingmar

    2017-01-01

    Development in marsupials is specialized towards an extremely short gestation and highly altricial newborns. As a result, marsupial neonates display morphological adaptations at birth related to functional constraints. However, little is known about the variability of marsupial skull development and its relation to morphological diversity. We studied bony skull development in five marsupial species. The relative timing of the onset of ossification was compared to literature data and the ossification sequence of the marsupial ancestor was reconstructed using squared-change parsimony. The high range of variation in the onset of ossification meant that no patterns could be observed that differentiate species. This finding challenges traditional studies concentrating on the onset of ossification as a marker for phylogeny or as a functional proxy. Our study presents observations on the developmental timing of cranial bone-to-bone contacts and their evolutionary implications. Although certain bone contacts display high levels of variation, connections of early and late development are quite conserved and informative. Bones that surround the oral cavity are generally the first to connect and the bones of the occipital region are among the last. We conclude that bone contact is preferable over onset of ossification for studying cranial bone development. PMID:28233826

  2. Lower extremity joint moments of collegiate soccer players differ between genders during a forward jump.

    PubMed

    Hart, Joseph M; Garrison, J Craig; Palmieri-Smith, Riann; Kerrigan, D Casey; Ingersoll, Christopher D

    2008-05-01

    Lower extremity kinetics while performing a single-leg forward jump landing may help explain gender biased risk for noncontact anterior cruciate ligament injury. Gender comparison of lower extremity joint angles and moments. Static groups comparison. Motion analysis laboratory. 8 male and 8 female varsity, collegiate soccer athletes. 5 single-leg landings from a 100cm forward jump. Peak and initial contact external joint moments and joint angles of the ankle, knee, and hip. At initial heel contact, males exhibited a adduction moment whereas females exhibited a abduction moment at the hip. Females also had significantly less peak hip extension moment and significantly less peak hip internal rotation moment than males had. Females exhibited greater knee adduction and hip internal rotation angles than men did. When decelerating from a forward jump, gender differences exist in forces acting at the hip.

  3. Axisymmetric shell analysis of the Space Shuttle solid rocket booster field joint

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.; Anderson, Melvin S.

    1989-01-01

    The Space Shuttle Challenger (STS 51-L) accident led to an intense investigation of the structural behavior of the solid rocket booster (SRB) tang and clevis field joints. The presence of structural deformations between the clevis inner leg and the tang, substantial enough to prevent the O-ring seals from eliminating hot gas flow through the joints, has emerged as a likely cause of the vehicle failure. This paper presents results of axisymmetric shell analyses that parametrically assess the structural behavior of SRB field joints subjected to quasi-steady-state internal pressure loading for both the original joint flown on mission STS 51-L and the redesigned joint recently flown on the Space Shuttle Discovery. Discussion of axisymmetric shell modeling issues and details is presented and a generic method for simulating contact between adjacent shells of revolution is described. Results are presented that identify the performance trends of the joints for a wide range of joint parameters.

  4. A sound and efficient measure of joint congruence.

    PubMed

    Conconi, Michele; Castelli, Vincenzo Parenti

    2014-09-01

    In the medical world, the term "congruence" is used to describe by visual inspection how the articular surfaces mate each other, evaluating the joint capability to distribute an applied load from a purely geometrical perspective. Congruence is commonly employed for assessing articular physiology and for the comparison between normal and pathological states. A measure of it would thus represent a valuable clinical tool. Several approaches for the quantification of joint congruence have been proposed in the biomechanical literature, differing on how the articular contact is modeled. This makes it difficult to compare different measures. In particular, in previous articles a congruence measure has been presented which proved to be efficient and suitable for the clinical practice, but it was still empirically defined. This article aims at providing a sound theoretical support to this congruence measure by means of the Winkler elastic foundation contact model which, with respect to others, has the advantage to hold also for highly conforming surfaces as most of the human articulations are. First, the geometrical relation between the applied load and the resulting peak of pressure is analytically derived from the elastic foundation contact model, providing a theoretically sound approach to the definition of a congruence measure. Then, the capability of congruence measure to capture the same geometrical relation is shown. Finally, the reliability of congruence measure is discussed. © IMechE 2014.

  5. Evaluation of effects of different treatments for the wrist joints of subdominant hands using joint proprioception and writing time.

    PubMed

    Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng

    2016-05-01

    [Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.

  6. Effect of Solder-Joint Geometry on the Low-Cycle Fatigue Behavior of Sn- xAg-0.7Cu

    NASA Astrophysics Data System (ADS)

    Lee, Hwa-Teng; Huang, Kuo-Chen

    2016-12-01

    Low-cycle fatigue tests of Sn-Ag-Cu (SAC) Pb-free solder joints under fixed displacement were performed to evaluate the influence of Ag content (0-3 wt.%) and solder-joint geometry (barrel and hourglass types) on solder-joint fatigue behavior and reliability. The solder joints were composed of fine particles of Ag3Sn and Cu6Sn5, which aggregated as an eutectic constituent at grain boundaries of the primary β-Sn phase and formed a dense network structure. A decrease in the Ag content resulted in coarsening of the β-Sn and eutectic phases, which, in turn, decreased the strength of the joint and caused earlier failure. Solder joints in the hourglass form exhibited better fatigue performance with longer life than barrel-type joints. The sharp contact angle formed between the solder and the Cu substrate by the barrel-type joints concentrated stress, which compromised fatigue reliability. The addition of Ag to the solder, however, enhanced fatigue performance because of strengthening caused by Ag3Sn formation. The cracks of the barrel-type SAC solder joints originated mostly at the contact corner and propagated along the interfacial layer between the interfacial intermetallic compound (IMC) and solder matrix. Hourglass-type solder joints, however, demonstrated both crack initiation and propagation in the solder matrix (solder mode). The addition of 1.5-2.0 wt.% Ag to SAC solder appears to enhance the fatigue performance of solder joints while maintaining sufficient strength.

  7. Is early osteoarthritis associated with differences in joint congruence?

    PubMed Central

    Conconi, Michele; Halilaj, Eni; Castelli, Vincenzo Parenti; Crisco, Joseph J.

    2014-01-01

    Previous studies suggest that osteoarthritis (OA) is related to abnormal or excessive articular contact stress. The peak pressure resulting from an applied load is determined by many factors, among which is shape and relative position and orientation of the articulating surfaces or, referring to a more common nomenclature, joint congruence. It has been hypothesized that anatomical differences may be among the causes of OA. Individuals with less congruent joints would likely develop higher peak pressure and thus would be more exposed to the risk of OA onset. The aim of this work was to determine if the congruence of the first carpometacarpal (CMC) joint differs with the early onset of OA or with sex, as the female population has a higher incidence of OA. 59 without and 38 with early OA were CT-scanned with their dominant or arthritic hand in a neutral configuration. The proposed measure of joint congruence is both shape and size dependent. The correlation of joint congruence with pathology and sex was analyzed both before and after normalization for joint size. We found a significant correlation between joint congruence and sex due to the sex-related differences in size. The observed correlation disappeared after normalization. Although joint congruence increased with size, it did not correlate significantly with the onset of early OA. Differences in joint congruence in this population may not be a primary cause of OA onset or predisposition, at least for the CMC joint. PMID:25468667

  8. Running Economy: Neuromuscular and Joint Stiffness Contributions in Trained Runners.

    PubMed

    Tam, Nicholas; Tucker, Ross; Santos-Concejero, Jordan; Prins, Danielle; Lamberts, Robert P

    2018-05-29

    It is debated whether running biomechanics make good predictors of running economy, with little known information about the neuromuscular and joint stiffness contributions to economical running gait. The aim of this study was to understand the relationship between certain neuromuscular and spatiotemporal biomechanical factors associated with running economy. Thirty trained runners performed a 6-minute constant-speed running set at 3.3 m∙s -1 , where oxygen consumption was assessed. Overground running trials were also performed at 3.3 m∙s -1 to assess kinematics, kinetics and muscle activity. Spatiotemporal gait variables, joint stiffness, pre-activation and stance phase muscle activity (gluteus medius; rectus femoris (RF); biceps femoris(BF); peroneus longus (PL); tibialis anterior (TA); gastrocnemius lateralis and medius (LG and MG) were variables of specific interest and thus determined. Additionally, pre-activation and ground contact of agonist:antagonist co-activation were calculated. More economical runners presented with short ground contact times (r=0.639, p<0.001) and greater strides frequencies (r=-0.630, p<0.001). Lower ankle and greater knee stiffness were associated with lower oxygen consumption (r=0.527, p=0.007 & r=0.384, p=0.043, respectively). Only LG:TA co-activation during stance were associated with lower oxygen cost of transport (r=0.672, p<0.0001). Greater muscle pre-activation and bi-articular muscle activity during stance were associated with more economical runners. Consequently, trained runners who exhibit greater neuromuscular activation prior to and during ground contact, in turn optimise spatiotemporal variables and joint stiffness, will be the most economical runners.

  9. A new method for measuring nocturnal tooth contacts.

    PubMed

    Yamashita, S; Ai, M; Mizutani, H

    1993-09-01

    A new portable system for measuring nocturnal tooth contacts has been devised. This system was suitable for patients to take home and record tooth contacts by themselves. A micro photo sensor using optical fibres was applied to detect tooth contacts. The sensor and the target were accurately fixed to opposed molars, respectively on the same side, with removable metal attachments. Patients were instructed to set the attachment to their tooth each experimental night. In the present study, data was assembled for four or five nights in three subjects who were free of masticatory pain and dysfunction. Each subject showed an individual tooth contact pattern. It is suggested that this new system is useful and convenient for measuring nocturnal tooth contacts.

  10. Direct Laser Writing of Nanophotonic Structures on Contact Lenses.

    PubMed

    AlQattan, Bader; Yetisen, Ali K; Butt, Haider

    2018-04-24

    Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.

  11. A musculoskeletal model of the elbow joint complex

    NASA Technical Reports Server (NTRS)

    Gonzalez, Roger V.; Barr, Ronald E.; Abraham, Lawrence D.

    1993-01-01

    This paper describes a musculoskeletal model that represents human elbow flexion-extension and forearm pronation-supination. Musculotendon parameters and the skeletal geometry were determined for the musculoskeletal model in the analysis of ballistic elbow joint complex movements. The key objective was to develop a computational model, guided by optimal control, to investigate the relationship among patterns of muscle excitation, individual muscle forces, and movement kinematics. The model was verified using experimental kinematic, torque, and electromyographic data from volunteer subjects performing both isometric and ballistic elbow joint complex movements. In general, the model predicted kinematic and muscle excitation patterns similar to what was experimentally measured.

  12. RETURN TO DIVISION IA FOOTBALL FOLLOWING A 1ST METATARSOPHALANGEAL JOINT DORSAL DISLOCATION

    PubMed Central

    Cook, Chad; Zarzour, Hap; Moorman, Claude T.

    2010-01-01

    Background. Although rare in occurrence, a dorsal dislocation of the 1st metatarsophalangeal (MTP) joint has been successfully treated using surgical and/or non-operative treatment. No descriptions of conservative intervention following a dorsal dislocation of the MTP joint in an athlete participating in a high contact sport are present in the literature. Objectives. The purpose of this case report is to describe the intervention and clinical reasoning during the rehabilitative process of a collegiate football player diagnosed with a 1st MTP joint dorsal dislocation. The plan of care and return to play criteria used for this athlete are presented. Case Description. The case involved a 19-year-old male Division IA football player, who suffered a traumatic dorsal dislocation of the 1st MTP joint during practice. The dislocation was initially treated on-site by closed reduction. Non-operative management included immobilization, therapeutic exercises, non-steroidal anti-inflammatories, manual treatment, modalities, prophylactic athletic taping, gait training, and a sport specific progression program for full return to Division IA football. Outcomes. Discharge from physical therapy occurred after six weeks of treatment. At discharge, no significant deviations existed during running, burst, and agility related drills. At a six-month follow-up, the patient reported full return to all football activities including contact drills without restrictions. Discussion. This case describes an effective six-week rehabilitation intervention for a collegiate football player who sustained a traumatic great toe dorsal dislocation. Further study is suggested to evaluate the intervention strategies and timeframe for return to contact sports. PMID:21589669

  13. Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking

    PubMed Central

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load. PMID:24260114

  14. Friction in total hip joint prosthesis measured in vivo during walking.

    PubMed

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  15. A methodology to accurately quantify patellofemoral cartilage contact kinematics by combining 3D image shape registration and cine-PC MRI velocity data.

    PubMed

    Borotikar, Bhushan S; Sipprell, William H; Wible, Emily E; Sheehan, Frances T

    2012-04-05

    Patellofemoral osteoarthritis and its potential precursor patellofemoral pain syndrome (PFPS) are common, costly, and debilitating diseases. PFPS has been shown to be associated with altered patellofemoral joint mechanics; however, an actual variation in joint contact stresses has not been established due to challenges in accurately quantifying in vivo contact kinematics (area and location). This study developed and validated a method for tracking dynamic, in vivo cartilage contact kinematics by combining three magnetic resonance imaging (MRI) techniques, cine-phase contrast (CPC), multi-plane cine (MPC), and 3D high-resolution static imaging. CPC and MPC data were acquired from 12 healthy volunteers while they actively extended/flexed their knee within the MRI scanner. Since no gold standard exists for the quantification of in vivo dynamic cartilage contact kinematics, the accuracy of tracking a single point (patellar origin relative to the femur) represented the accuracy of tracking the kinematics of an entire surface. The accuracy was determined by the average absolute error between the PF kinematics derived through registration of MPC images to a static model and those derived through integration of the CPC velocity data. The accuracy ranged from 0.47 mm to 0.77 mm for the patella and femur and from 0.68 mm to 0.86 mm for the patellofemoral joint. For purely quantifying joint kinematics, CPC remains an analytically simpler and more accurate (accuracy <0.33 mm) technique. However, for application requiring the tracking of an entire surface, such as quantifying cartilage contact kinematics, this combined imaging approach produces accurate results with minimal operator intervention. Published by Elsevier Ltd.

  16. Walking velocity and step length adjustments affect knee joint contact forces in healthy weight and obese adults.

    PubMed

    Milner, Clare E; Meardon, Stacey A; Hawkins, Jillian L; Willson, John D

    2018-04-28

    Knee osteoarthritis is a major public health problem and adults with obesity are particularly at risk. One approach to alleviating this problem is to reduce the mechanical load at the joint during daily activity. Adjusting temporospatial parameters of walking could mitigate cumulative knee joint mechanical loads. The purpose of this study was to determine how adjustments to velocity and step length affects knee joint loading in healthy weight adults and adults with obesity. We collected three-dimensional gait analysis data on 10 adults with a normal body mass index and 10 adults with obesity during over ground walking in nine different conditions. In addition to preferred velocity and step length, we also conducted combinations of 15% increased and decreased velocity and step length. Peak tibiofemoral joint impulse and knee adduction angular impulse were reduced in the decreased step length conditions in both healthy weight adults (main effect) and those with obesity (interaction effect). Peak knee joint adduction moment was also reduced with decreased step length, and with decreased velocity in both groups. We conclude from these results that adopting shorter step lengths during daily activity and when walking for exercise can reduce mechanical stimuli associated with articular cartilage degenerative processes in adults with and without obesity. Thus, walking with reduced step length may benefit adults at risk for disability due to knee osteoarthritis. Adopting a shorter step length during daily walking activity may reduce knee joint loading and thus benefit those at risk for knee cartilage degeneration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:XX-XX, 2018. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Influence of step rate and quadriceps load distribution on patellofemoral cartilage contact pressures during running.

    PubMed

    Lenhart, Rachel L; Smith, Colin R; Vignos, Michael F; Kaiser, Jarred; Heiderscheit, Bryan C; Thelen, Darryl G

    2015-08-20

    Interventions used to treat patellofemoral pain in runners are often designed to alter patellofemoral mechanics. This study used a computational model to investigate the influence of two interventions, step rate manipulation and quadriceps strengthening, on patellofemoral contact pressures during running. Running mechanics were analyzed using a lower extremity musculoskeletal model that included a knee with six degree-of-freedom tibiofemoral and patellofemoral joints. An elastic foundation model was used to compute articular contact pressures. The lower extremity model was scaled to anthropometric dimensions of 22 healthy adults, who ran on an instrumented treadmill at 90%, 100% and 110% of their preferred step rate. Numerical optimization was then used to predict the muscle forces, secondary tibiofemoral kinematics and all patellofemoral kinematics that would generate the measured primary hip, knee and ankle joint accelerations. Mean and peak patella contact pressures reached 5.0 and 9.7MPa during the midstance phase of running. Increasing step rate by 10% significantly reduced mean contact pressures by 10.4% and contact area by 7.4%, but had small effects on lateral patellar translation and tilt. Enhancing vastus medialis strength did not substantially affect pressure magnitudes or lateral patellar translation, but did shift contact pressure medially toward the patellar median ridge. Thus, the model suggests that step rate tends to primarily modulate the magnitude of contact pressure and contact area, while vastus medialis strengthening has the potential to alter mediolateral pressure locations. These results are relevant to consider in the design of interventions used to prevent or treat patellofemoral pain in runners. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Modular and hierarchical structure of social contact networks

    NASA Astrophysics Data System (ADS)

    Ge, Yuanzheng; Song, Zhichao; Qiu, Xiaogang; Song, Hongbin; Wang, Yong

    2013-10-01

    Social contact networks exhibit overlapping qualities of communities, hierarchical structure and spatial-correlated nature. We propose a mixing pattern of modular and growing hierarchical structures to reconstruct social contact networks by using an individual’s geospatial distribution information in the real world. The hierarchical structure of social contact networks is defined based on the spatial distance between individuals, and edges among individuals are added in turn from the modular layer to the highest layer. It is a gradual process to construct the hierarchical structure: from the basic modular model up to the global network. The proposed model not only shows hierarchically increasing degree distribution and large clustering coefficients in communities, but also exhibits spatial clustering features of individual distributions. As an evaluation of the method, we reconstruct a hierarchical contact network based on the investigation data of a university. Transmission experiments of influenza H1N1 are carried out on the generated social contact networks, and results show that the constructed network is efficient to reproduce the dynamic process of an outbreak and evaluate interventions. The reproduced spread process exhibits that the spatial clustering of infection is accordant with the clustering of network topology. Moreover, the effect of individual topological character on the spread of influenza is analyzed, and the experiment results indicate that the spread is limited by individual daily contact patterns and local clustering topology rather than individual degree.

  19. Changes in in vivo knee contact forces through gait modification.

    PubMed

    Kinney, Allison L; Besier, Thor F; Silder, Amy; Delp, Scott L; D'Lima, Darryl D; Fregly, Benjamin J

    2013-03-01

    Knee osteoarthritis (OA) commonly occurs in the medial compartment of the knee and has been linked to overloading of the medial articular cartilage. Gait modification represents a non-invasive treatment strategy for reducing medial compartment knee force. The purpose of this study was to evaluate the effectiveness of a variety of gait modifications that were expected to alter medial contact force. A single subject implanted with a force-measuring knee replacement walked using nine modified gait patterns, four of which involved different hiking pole configurations. Medial and lateral contact force at 25, 50, and 75% of stance phase, and the average value over all of stance phase (0-100%), were determined for each gait pattern. Changes in medial and lateral contact force values relative to the subject's normal gait pattern were determined by a Kruskal-Wallis test. Apart from early stance (25% of stance), medial contact force was most effectively reduced by walking with long hiking poles and wide pole placement, which significantly reduced medial and lateral contact force during stance phase by up to 34% (at 75% of stance) and 26% (at 50% of stance), respectively. Although this study is based on data from a single subject, the results provide important insight into changes in medial and lateral contact forces through gait modification. The results of this study suggest that an optimal configuration of bilateral hiking poles may significantly reduce both medial and lateral compartment knee forces in individuals with medial knee osteoarthritis. Copyright © 2012 Orthopaedic Research Society.

  20. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep

    PubMed Central

    Manlove, Kezia R.; Cassirer, E. Frances; Plowright, Raina K.; Cross, Paul C.; Hudson, Peter J.

    2018-01-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife.We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia.We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections.Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs.Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit.This analysis demonstrates a simple logistic regression approach for testing a priori

  1. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep

    USGS Publications Warehouse

    Manlove, Kezia R.; Cassirer, E. Frances; Plowright, Raina K.; Cross, Paul C.; Hudson, Peter J.

    2017-01-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife.We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia.We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections.Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs.Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit.This analysis demonstrates a simple logistic regression approach for testing

  2. Conflict resolution patterns and longevity of adolescent romantic couples: a 2-year follow-up study.

    PubMed

    Shulman, Shmuel; Tuval-Mashiach, Rivka; Levran, Elisheva; Anbar, Shmuel

    2006-08-01

    This study examined the predictors of longevity among 40 late adolescent romantic couples (mean age males=17.71 years; mean age females=17.18 years). Subjects were given a revealed differences task where they were asked to solve their disagreements. The joint task was recorded, transcribed and analysed by two raters. At 3, 6, 9, 12, 18, and 24 months after this procedure, partners were contacted by telephone and asked whether their relationship was still intact. A cluster analysis was performed on couples' interaction indices and yielded three distinctive conflict resolution patterns. The Downplaying pattern was characterized by a high tendency to minimize the conflict. The relationships of the adolescents displaying this pattern stayed intact for a period of 9 months. Half of them were still together after 24 months. The adolescents displaying the Integrative pattern, which shows a good ability to negotiate differences tended to stay together over a period of 24 months. Those showing the Conflictive pattern, characterized by a confrontative interaction, were separated by the 3 months follow-up. Results are discussed within the context of developmental perspectives of conflict resolution tendencies and adolescent romance.

  3. Analysis of polyethylene terephthalate PET plastic bottle jointing system using finite element method (FEM)

    NASA Astrophysics Data System (ADS)

    Zaidi, N. A.; Rosli, Muhamad Farizuan; Effendi, M. S. M.; Abdullah, Mohamad Hariri

    2017-09-01

    For almost all injection molding applications of Polyethylene Terephthalate (PET) plastic was analyzed the strength, durability and stiffness of properties by using Finite Element Method (FEM) for jointing system of wood furniture. The FEM was utilized for analyzing the PET jointing system for Oak and Pine as wood based material of furniture. The difference pattern design of PET as wood jointing furniture gives the difference value of strength furniture itself. The results show the wood specimen with grooves and eclipse pattern design PET jointing give lower global estimated error is 28.90%, compare to the rectangular and non-grooves wood specimen of global estimated error is 63.21%.

  4. Finite Element Analysis for Turbine Blades with Contact Problems

    NASA Astrophysics Data System (ADS)

    Yang, Yuan-Jian; Yang, Liang; Wang, Hai-Kun; Zhu, Shun-Peng; Huang, Hong-Zhong

    2016-12-01

    Turbine blades are one of the key components in a typical turbofan engine, which plays an important role in flight safety. In this paper, we establish a establishes a three-dimensional finite element model of the turbine blades, then analyses the strength of the blade in complicated conditions under the joint function of temperature load, centrifugal load, and aerodynamic load. Furthermore, contact analysis of blade tenon and dovetail slot is also carried out to study the stress based on the contact elements. Finally, the Von Mises stress-strain distributions are obtained to acquire the several dangerous points and maximum Von Mises stress, which provide the basis for life prediction of turbine blade.

  5. Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness.

    PubMed

    Abduo, Jaafar

    2017-01-01

    This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.

  6. Managing outdoor recreation in California: visitor contact studies

    Treesearch

    Deborah J. Chavez

    2001-01-01

    Findings from 30 outdoor recreation visitor contact studies that wereconducted in California between 1989 and 1998 are summarized. Analyses focuson recreationist profiles, patterns of participation, beliefs and opinions,communication patterns, and depreciative behaviors. Although the “typical”respondent to the survey sites was white, there were many sites where...

  7. Effect of partial meniscectomy at the medial posterior horn on tibiofemoral contact mechanics and meniscal hoop strains in human knees.

    PubMed

    Seitz, Andreas Martin; Lubomierski, Anja; Friemert, Benedikt; Ignatius, Anita; Dürselen, Lutz

    2012-06-01

    We examined the influence of partial meniscectomy of 10 mm width on 10 human cadaveric knee joints, as it is performed during the treatment of radial tears in the posterior horn of the medial meniscus, on maximum contact pressure, contact area (CA), and meniscal hoop strain in the lateral and medial knee compartments. In case of 0° and 30° flexion angle, 20% and 50% partial meniscectomy did not influence maximum contact pressure and area. Only in case of 60° knee flexion, 50% partial resection increased medial maximum contact pressure and decreased the medial CA statistically significant. However, 100% partial resection increased maximum contact pressure and decreased CA significantly in the meniscectomized medial knee compartment in all tested knee positions. No significant differences were noted for meniscal hoop strain. From a biomechanical point of view, our in vitro study suggests that the medial joint compartment is not in danger of accelerated cartilage degeneration up to a resection limit of 20% meniscal depth and 10 mm width. Contact mechanics are likely to be more sensitive to partial meniscectomy at higher flexion angles, which has to be further investigated. Copyright © 2011 Orthopaedic Research Society.

  8. In vivo gliding and contact characteristics of the sigmoid notch and the ulna in forearm rotation.

    PubMed

    Chen, Yan Rong; Tang, Jin Bo

    2013-08-01

    To investigate shifting of the contact center over the surfaces of 2 opposing bones of the distal radioulnar joint during forearm rotation. We recruited 8 volunteers and used their right wrists. Serial computed tomography scans were obtained with the forearm at neutral position and 6 other positions of forearm rotation. We reconstructed 3-dimensional images and mapped contact regions of both the sigmoid notch and ulnar head by calculating the shortest distance between the 2 opposing bones. The center of contact was also defined and plotted against the distal radioulnar joint rotation to determine the sliding distance over the surfaces of the 2 bones. During forearm rotation, the maximal sliding of the sigmoid notch over the ulnar head was 7.4 mm in forearm pronation and 9.2 mm in forearm supination, which occurred in volar-dorsal direction primarily. Sliding of the ulnar head over the sigmoid notch was more limited, measuring 4.7 mm during pronation and 2.3 mm during supination. Most of the motion occurred between 30° pronation and 60° supination. In the proximal-distal direction, the contact site of the sigmoid notch with the ulnar head translated distally 1.6 mm during pronation and proximally 0.7 mm during supination. During forearm rotation, the sigmoid notch slides substantially against the ulnar head at each part of the forearm rotation arc. The sliding of the ulnar head over the sigmoid notch is smaller, most of which is at the range from moderate forearm pronation to slight supination. The contact site of the sigmoid notch with the ulnar head moves slightly distally during forearm pronation and proximally during supination. The in vivo findings provide more detailed information and insight into distal radioulnar joint motion kinematics. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Short-circuit current improvement in thin cells with a gridded back contact

    NASA Technical Reports Server (NTRS)

    Giuliano, M.; Wohlgemuth, J.

    1980-01-01

    The use of gridded back contact on thin silicon solar cells 50 micrometers was investigated. An unexpected increase in short circuit current of almost 10 percent was experienced for 2 cm x 2 cm cells. Control cells with the standard continuous contact metallization were fabricated at the same time as the gridded back cells with all processes identical up to the formation of the back contact. The gridded back contact pattern was delineated by evaporation of Ti-Pd over a photo-resist mask applied to the back of the wafer; the Ti-Pd film on the controls was applied in the standard fashion in a continuous layer over the back of the cell. The Ti-Pd contacts were similarly applied to the front of the wafer, and the grid pattern on both sides of the cell was electroplated with 8-10 micrometers of silver.

  10. Load transfer in the stiffener-to-skin joints of a pressurized fuselage

    NASA Technical Reports Server (NTRS)

    Johnson, Eric R.; Rastogi, Naveen

    1995-01-01

    Structural analyses are developed to determine the linear elastic and the geometrically nonlinear elastic response of an internally pressurized, orthogonally stiffened, composite material cylindrical shell. The configuration is a long circular cylindrical shell stiffened on the inside by a regular arrangement of identical stringers and identical rings. Periodicity permits the analysis of a unit cell model consisting of a portion of the shell wall centered over one stringer-ring joint. The stringer-ring-shell joint is modeled in an idealized manner; the stiffeners are mathematically permitted to pass through one another without contact, but do interact indirectly through their mutual contact with the shell at the joint. Discrete beams models of the stiffeners include a stringer with a symmetrical cross section and a ring with either a symmetrical or an asymmetrical open section. Mathematical formulations presented for the linear response include the effect of transverse shear deformations and the effect of warping of the ring's cross section due to torsion. These effects are important when the ring has an asymmetrical cross section because the loss of symmetry in the problem results in torsion and out-of-plane bending of the ring, and a concomitant rotation of the joint at the stiffener intersection about the circumferential axis. Data from a composite material crown panel typical of a large transport fuselage structure are used for two numerical examples. Although the inclusion of geometric nonlinearity reduces the 'pillowing' of the shell, it is found that bending is localized to a narrow region near the stiffener. Including warping deformation of the ring into the analysis changes the sense of the joint rotation. Transverse shear deformation models result in increased joint flexibility.

  11. Is early osteoarthritis associated with differences in joint congruence?

    PubMed

    Conconi, Michele; Halilaj, Eni; Parenti Castelli, Vincenzo; Crisco, Joseph J

    2014-12-18

    Previous studies suggest that osteoarthritis (OA) is related to abnormal or excessive articular contact stress. The peak pressure resulting from an applied load is determined by many factors, among which is shape and relative position and orientation of the articulating surfaces or, referring to a more common nomenclature, joint congruence. It has been hypothesized that anatomical differences may be among the causes of OA. Individuals with less congruent joints would likely develop higher peak pressure and thus would be more exposed to the risk of OA onset. The aim of this work was to determine if the congruence of the first carpometacarpal (CMC) joint differs with the early onset of OA or with sex, as the female population has a higher incidence of OA. 59 without and 38 with early OA were CT-scanned with their dominant or arthritic hand in a neutral configuration. The proposed measure of joint congruence is both shape and size dependent. The correlation of joint congruence with pathology and sex was analyzed both before and after normalization for joint size. We found a significant correlation between joint congruence and sex due to the sex-related differences in size. The observed correlation disappeared after normalization. Although joint congruence increased with size, it did not correlate significantly with the onset of early OA. Differences in joint congruence in this population may not be a primary cause of OA onset or predisposition, at least for the CMC joint. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Comparison of self-reported and observed water contact in an S. mansoni endemic village in Brazil.

    PubMed

    Friedman, J F; Kurtis, J D; McGarvey, S T; Fraga, A L; Silveira, A; Pizziolo, V; Gazzinelli, G; LoVerde, P; Corrêa-Oliveira, R

    2001-03-30

    Estimates of exposure are critical for immuno-epidemiologic and intervention studies in human schistosomiasis. Direct observation of human water contact patterns is both costly and time consuming. To address these issues, we determined whether individuals residing in a Schistosoma mansoni endemic village in Brazil could accurately self-report their water contact patterns. We compared the results of a water contact questionnaire to the present gold standard, direct observation of water contact in 86 volunteers, aged 8--29. We administered a survey to estimate volunteers' frequency and type of water contact and directly measured each volunteers' water contact patterns during 5 weeks of detailed water contact observations. We found a poor correlation between self reported frequency of contact and directly observed exposure (rho=0.119, P=NS). The questionnaire data was supplemented by information about average body surface area of exposure and duration of contact for specific activities derived from observations of this cohort. This 'supplemented questionnaire' data was significantly correlated with their exposure index (rho=0.227, P=0.05). It provides a starting point from which questionnaires may develop to provide a more cost-effective and less labor intensive method of assessing water contact exposure at the level of the individual.

  13. Movement-Pattern Training to Improve Function in People With Chronic Hip Joint Pain: A Feasibility Randomized Clinical Trial.

    PubMed

    Harris-Hayes, Marcie; Czuppon, Sylvia; Van Dillen, Linda R; Steger-May, Karen; Sahrmann, Shirley; Schootman, Mario; Salsich, Gretchen B; Clohisy, John C; Mueller, Michael J

    2016-06-01

    Study Design Feasibility randomized clinical trial. Background Rehabilitation may be an appropriate treatment strategy for patients with chronic hip joint pain; however, the evidence related to the effectiveness of rehabilitation is limited. Objectives To assess feasibility of performing a randomized clinical trial to investigate the effectiveness of movement-pattern training (MPT) to improve function in people with chronic hip joint pain. Methods Thirty-five patients with chronic hip joint pain were randomized into a treatment (MPT) group or a control (wait-list) group. The MPT program included 6 one-hour supervised sessions and incorporated (1) task-specific training for basic functional tasks and symptom-provoking tasks, and (2) strengthening of hip musculature. The wait-list group received no treatment. Primary outcomes for feasibility were patient retention and adherence. Secondary outcomes to assess treatment effects were patient-reported function (Hip disability and Osteoarthritis Outcome Score), lower extremity kinematics, and hip muscle strength. Results Retention rates did not differ between the MPT (89%) and wait-list groups (94%, P = 1.0). Sixteen of the 18 patients (89%) in the MPT group attended at least 80% of the treatment sessions. For the home exercise program, 89% of patients reported performing their home program at least once per day. Secondary outcomes support the rationale for conduct of a superiority randomized clinical trial. Conclusion Based on retention and adherence rates, a larger randomized clinical trial appears feasible and warranted to assess treatment effects more precisely. Data from this feasibility study will inform our future clinical trial. Level of Evidence Therapy, level 2b-. J Orthop Sports Phys Ther 2016;46(6):452-461. Epub 26 Apr 2016. doi:10.2519/jospt.2016.6279.

  14. Dynamic Fragmentation of Jointed Rock Blocks During Rockslide-Avalanches: Insights From Discrete Element Analyses

    NASA Astrophysics Data System (ADS)

    Zhao, Tao; Crosta, Giovanni Battista; Dattola, Giuseppe; Utili, Stefano

    2018-04-01

    The dynamic fragmentation of jointed rock blocks during rockslide avalanches has been investigated by discrete element method simulations for a multiple arrangement of a rock block sliding over a simple slope geometry. The rock blocks are released along an inclined sliding plane and subsequently collide onto a flat horizontal plane at a sharp kink point. The contact force chains generated by the impact appear initially at the bottom frontal corner of the rock block and then propagate radially upward to the top rear part of the block. The jointed rock blocks exhibit evident contact force concentration and discontinuity of force wave propagation near the joint, associating with high energy dissipation of granular dynamics. The corresponding force wave propagation velocity can be less than 200 m/s, which is much smaller than that of an intact rock (1,316 m/s). The concentration of contact forces at the bottom leads to high rock fragmentation intensity and momentum boosts, facilitating the spreading of many fine fragments to the distal ends. However, the upper rock block exhibits very low rock fragmentation intensity but high energy dissipation due to intensive friction and damping, resulting in the deposition of large fragments near the slope toe. The size and shape of large fragments are closely related to the orientation and distribution of the block joints. The cumulative fragment size distribution can be well fitted by the Weibull's distribution function, with very gentle and steep curvatures at the fine and coarse size ranges, respectively. The numerical results of fragment size distribution can match well some experimental and field observations.

  15. Finite Element Analysis of the Maximum Stress at the Joints of the Transmission Tower

    NASA Astrophysics Data System (ADS)

    Itam, Zarina; Beddu, Salmia; Liyana Mohd Kamal, Nur; Bamashmos, Khaled H.

    2016-03-01

    Transmission towers are tall structures, usually a steel lattice tower, used to support an overhead power line. Usually, transmission towers are analyzed as frame-truss systems and the members are assumed to be pin-connected without explicitly considering the effects of joints on the tower behavior. In this research, an engineering example of joint will be analyzed with the consideration of the joint detailing to investigate how it will affect the tower analysis. A static analysis using STAAD Pro was conducted to indicate the joint with the maximum stress. This joint will then be explicitly analyzed in ANSYS using the Finite Element Method. Three approaches were used in the software which are the simple plate model, bonded contact with no bolts, and beam element bolts. Results from the joint analysis show that stress values increased with joint details consideration. This proves that joints and connections play an important role in the distribution of stress within the transmission tower.

  16. Electromyographic preactivation pattern of the gluteus medius during weight-bearing functional tasks in women with and without anterior knee pain.

    PubMed

    Nakagawa, Theresa H; Muniz, Thiago B; Baldon, Rodrigo M; Maciel, Carlos D; Amorim, César F; Serrão, Fábio V

    2011-01-01

    Proximal factors have been proposed to influence the biomechanics of the patellofemoral joint. A delayed or diminished gluteus medius (GM) activation, before the foot contact on the ground during functional activities could lead to excessive femur adduction and internal rotation and be associated with anterior knee pain (AKP). There are few studies on this topic and the results were inconclusive, therefore, it is necessary to investigate the GM preactivation pattern during functional activities. To compare the GM electromyographic (EMG) preactivation pattern during walking, descending stairs and in single leg jump task in women with and without AKP. Nine women clinically diagnosed with AKP and ten control subjects with no history of knee injury participated in this study. We evaluated GM EMG linear envelope before the foot contact on the ground during walking and GM onset time and EMG linear envelope during descending stairs as well as in a single leg vertical jump. Mann-Whitney U tests were used to determine the between-group differences in GM EMG preactivation pattern. No between-group differences were observed in GM linear envelope during walking (P=0.41), GM onset time and linear envelope during descending stairs (P=0.17 and P=0.15) and single leg jump (P=0.81 and P=0.33). Women with AKP did not demonstrated altered GM preactivation pattern during functional weight bearing activities. Our results did not support the hypothesis that poor GM preactivation pattern could be associated with AKP.

  17. Optical critical dimension metrology for directed self-assembly assisted contact hole shrink

    NASA Astrophysics Data System (ADS)

    Dixit, Dhairya; Green, Avery; Hosler, Erik R.; Kamineni, Vimal; Preil, Moshe E.; Keller, Nick; Race, Joseph; Chun, Jun Sung; O'Sullivan, Michael; Khare, Prasanna; Montgomery, Warren; Diebold, Alain C.

    2016-01-01

    Directed self-assembly (DSA) is a potential patterning solution for future generations of integrated circuits. Its main advantages are high pattern resolution (˜10 nm), high throughput, no requirement of high-resolution mask, and compatibility with standard fab-equipment and processes. The application of Mueller matrix (MM) spectroscopic ellipsometry-based scatterometry to optically characterize DSA patterned contact hole structures fabricated with phase-separated polystyrene-b-polymethylmethacrylate (PS-b-PMMA) is described. A regression-based approach is used to calculate the guide critical dimension (CD), DSA CD, height of the PS column, thicknesses of underlying layers, and contact edge roughness of the post PMMA etch DSA contact hole sample. Scanning electron microscopy and imaging analysis is conducted as a comparative metric for scatterometry. In addition, optical model-based simulations are used to investigate MM elements' sensitivity to various DSA-based contact hole structures, predict sensitivity to dimensional changes, and its limits to characterize DSA-induced defects, such as hole placement inaccuracy, missing vias, and profile inaccuracy of the PMMA cylinder.

  18. A Non-Contact Measurement System for the Range of Motion of the Hand

    PubMed Central

    Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse

    2015-01-01

    An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976

  19. Activation Pattern of Lower Leg Muscles in Running on Asphalt, Gravel and Grass.

    PubMed

    Dolenec, Aleš; Štirn, Igor; Strojnik, Vojko

    2015-07-01

    Running is performed on different natural surfaces (outdoor) and artificial surfaces (indoor). Different surface characteristics cause modification of the lower leg muscle activation pattern to adopt ankle stiffness to these characteristics. So the purpose of our investigation was to study changes of lower leg muscles activation pattern in running on different natural running surfaces. Six male and two female runners participated. The participants ran at a freely chosen velocity in trials on asphalt while in trials on gravel, and grass surfaces they were attempting to reach similar velocities as in the trials on asphalt. Muscle activation of the peroneus brevis, tibialis anterior, soleus, and gastrocnemius medialis of the right leg was recorded. Running on asphalt increased average EMG amplitude of the m. tibialis anterior in the pre-activation phase and the m. gastrocnemius medialis in the entire contact phase compared to running on grass from 0.222 ± 0.113 V to 0.276 ± 0.136 V and from 0.214 ± 0.084 V to 0.238 ± 0.088 V, respectively. The average EMG of m. peroneus brevis in pre-activation phase increased from 0.156 ± 0.026 V to 0.184 ± 0.455 V in running on grass in comparison to running on gravel. Running on different surfaces is connected with different activation patterns of lower leg muscles. Running on asphalt requires stiff ankle joints, running on gravel requires greater stability in ankle joints, while running on grass is the least demanding on lower leg muscles.

  20. Method of forming contacts for a back-contact solar cell

    DOEpatents

    Manning, Jane

    2015-10-20

    Methods of forming contacts for solar cells are described. In one embodiment, a method includes forming a silicon layer above a substrate, forming and patterning a solid-state p-type dopant source on the silicon layer, forming an n-type dopant source layer over exposed regions of the silicon layer and over a plurality of regions of the solid-state p-type dopant source, and heating the substrate to provide a plurality of n-type doped silicon regions among a plurality of p-type doped silicon regions.

  1. Method of forming contacts for a back-contact solar cell

    DOEpatents

    Manning, Jane

    2014-07-15

    Methods of forming contacts for solar cells are described. In one embodiment, a method includes forming a silicon layer above a substrate, forming and patterning a solid-state p-type dopant source on the silicon layer, forming an n-type dopant source layer over exposed regions of the silicon layer and over a plurality of regions of the solid-state p-type dopant source, and heating the substrate to provide a plurality of n-type doped silicon regions among a plurality of p-type doped silicon regions.

  2. Influence of meniscus shape in the cross sectional plane on the knee contact mechanics.

    PubMed

    Łuczkiewicz, Piotr; Daszkiewicz, Karol; Witkowski, Wojciech; Chróścielewski, Jacek; Zarzycki, Witold

    2015-06-01

    We present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with complete radial posterior meniscus root tear and knee with total meniscectomy of medial or lateral meniscus. We investigate how the meniscus shape in the cross sectional plane influences knee-joint mechanics by comparing the results for flat (degenerated) lateral and normal medial meniscus. Specifically, the deformation of the menisci in the coronal plane and the corresponding stress values in cartilages are studied. By analysing contact resultant force acting on the menisci in axial plane we have shown that restricted extrusion of the torn lateral meniscus can be attributed to small slope of its cross section in the coronal plane. Additionally, the change of the contact area and the resultant force acting on the menisci as the function of compressive load are investigated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Potential for Non-Contact ACL Injury Between Step-Close-Jump and Hop-Jump Tasks.

    PubMed

    Wang, Li-I; Gu, Chin-Yi; Chen, Wei-Ling; Chang, Mu-San

    2010-01-01

    This study aimed to compare the kinematics and kinetics during the landing of hop-jump and step-close-jump movements in order to provide further inferring that the potential risk of ACL injuries. Eleven elite male volleyball players were recruited to perform hop-jump and step-close-jump tasks. Lower extremity kinematics and ground reaction forces during landing in stop-jump tasks were recorded. Lower extremity kinetics was calculated by using an inverse dynamic process. Step-close-jump tasks demonstrated smaller peak proximal tibia anterior shear forces during the landing phase. In step-close-jump tasks, increasing hip joint angular velocity during initial foot-ground contact decreased peak posterior ground reaction force during the landing phase, which theoretically could reduce the risk of ACL injury. Key pointsThe different landing techniques required for these two stop-jump tasks do not necessarily affect the jump height.Hop-jump decreased the hip joint angular velocity at initial foot contact with ground, which could lead to an increasing peak posterior GRF during the landing phase.Hop-jump decreased hip and knee joint angular flexion displacement during the landing, which could increase the peak vertical loading rate during the landing phase.

  4. Gait Analysis in Rats with Single Joint Inflammation: Influence of Experimental Factors

    PubMed Central

    Ängeby Möller, Kristina; Kinert, Susanne; Størkson, Rolf; Berge, Odd-Geir

    2012-01-01

    Disability and movement-related pain are major symptoms of joint disease, motivating the development of methods to quantify motor behaviour in rodent joint pain models. We used observational scoring and automated methods to compare weight bearing during locomotion and during standing after single joint inflammation induced by Freund's complete adjuvant (0.12–8.0 mg/mL) or carrageenan (0.47–30 mg/mL). Automated gait analysis was based on video capture of prints generated by light projected into the long edge of the floor of a walkway, producing an illuminated image of the contact area of each paw with light intensity reflecting the contact pressure. Weight bearing was calculated as an area-integrated paw pressure, that is, the light intensity of all pixels activated during the contact phase of a paw placement. Automated static weight bearing was measured with the Incapacitance tester. Pharmacological sensitivity of weight-bearing during locomotion was tested in carrageenan-induced monoarthritis by administration of the commonly used analgesics diclofenac, ibuprofen, and naproxen, as well as oxycodone and paracetamol. Observational scoring and automated quantification yielded similar results. We found that the window between control rats and monoarthritic rats was greater during locomotion. The response was more pronounced for inflammation in the ankle as compared to the knee, suggesting a methodological advantage of using this injection site. The effects of both Freund's complete adjuvant and carrageenan were concentration related, but Freund's incomplete adjuvant was found to be as effective as lower, commonly used concentrations of the complete adjuvant. The results show that gait analysis can be an effective method to quantify behavioural effects of single joint inflammation in the rat, sensitive to analgesic treatment. PMID:23071540

  5. Refining patterns of joint hypermobility, habitus, and orthopedic traits in joint hypermobility syndrome and Ehlers-Danlos syndrome, hypermobility type.

    PubMed

    Morlino, Silvia; Dordoni, Chiara; Sperduti, Isabella; Venturini, Marina; Celletti, Claudia; Camerota, Filippo; Colombi, Marina; Castori, Marco

    2017-04-01

    Joint hypermobility syndrome (JHS) and Ehlers-Danlos syndrome, hypermobility type (EDS-HT) are two overlapping heritable disorders (JHS/EDS-HT) recognized by separated sets of diagnostic criteria and still lack a confirmatory test. This descriptive research was aimed at better characterizing the clinical phenotype of JHS/EDS-HT with focus on available diagnostic criteria, and in order to propose novel features and assessment strategies. One hundred and eighty-nine (163 females, 26 males; age: 2-73 years) patients from two Italian reference centers were investigated for Beighton score, range of motion in 21 additional joints, rate and sites of dislocations and sprains, recurrent soft-tissue injuries, tendon and muscle ruptures, body mass index, arm span/height ratio, wrist and thumb signs, and 12 additional orthopedic features. Rough rates were compared by age, sex, and handedness with a series of parametric and non-parametric tools. Multiple correspondence analysis was carried out for possible co-segregations of features. Beighton score and hypermobility at other joints were influenced by age at diagnosis. Rate and sites of joint instability complications did not vary according to age at diagnosis except for soft-tissue injuries. No major difference was registered by sex and dominant versus non-dominant body side. At multiple correspondence analysis, selected features tend to co-segregate in a dichotomous distribution. Dolichostenomelia and arachnodactyly segregated independently. This study pointed out a more protean musculoskeletal phenotype than previously considered according to available diagnostic criteria for JHS/EDS-HT. Our findings corroborated the need for a re-thinking of JHS/EDS-HT on clinical grounds in order to find better therapeutic and research strategies. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Regional Sign Language Varieties in Contact: Investigating Patterns of Accommodation

    ERIC Educational Resources Information Center

    Stamp, Rose; Schembri, Adam; Evans, Bronwen G.; Cormier, Kearsy

    2016-01-01

    Short-term linguistic accommodation has been observed in a number of spoken language studies. The first of its kind in sign language research, this study aims to investigate the effects of regional varieties in contact and lexical accommodation in British Sign Language (BSL). Twenty-five participants were recruited from Belfast, Glasgow,…

  7. Thermal Conductance of Pressed Bimetal Contact Pairs at Liquid Nitrogen Temperatures

    NASA Technical Reports Server (NTRS)

    Kittle, Peter; Salerno, Louis J.; Spivak, Alan L.

    1994-01-01

    Large Dewars often use aluminum radiation shields and stainless steel vent lines. A simple, low cost method of making thermal contact between the shield and the line is to deform the shield around the line. A knowledge of the thermal conductance of such a joint is needed to thermally analyze the system. The thermal conductance of pressed metal contacts consisting of one aluminum and one stainless steel contact has been measured at 77 K, with applied forces from 8.9 N to 267 N. Both 5052 or 5083 aluminum were used as the upper contact. The lower contact was 304L stainless steel. The thermal conductance was found to be linear in temperature over the narrow temperature range of measurement. As the force was increased, the thermal conductance ranged from roughly 9 to 21 mW/K within a range of errors from 3% to 8%. Within the range of error no difference could be found between the using either of the aluminum alloys as the upper contact. Extrapolating the data to zero applied force does not result in zero thermal conductance. Possible causes of this anomalous effect are discussed.

  8. New patterns in human biogeography revealed by networks of contacts between linguistic groups.

    PubMed

    Capitán, José A; Bock Axelsen, Jacob; Manrubia, Susanna

    2015-03-07

    Human languages differ broadly in abundance and are distributed highly unevenly on the Earth. In many qualitative and quantitative aspects, they strongly resemble biodiversity distributions. An intriguing and previously unexplored issue is the architecture of the neighbouring relationships between human linguistic groups. Here we construct and characterize these networks of contacts and show that they represent a new kind of spatial network with uncommon structural properties. Remarkably, language networks share a meaningful property with food webs: both are quasi-interval graphs. In food webs, intervality is linked to the existence of a niche space of low dimensionality; in language networks, we show that the unique relevant variable is the area occupied by the speakers of a language. By means of a range model analogous to niche models in ecology, we show that a geometric restriction of perimeter covering by neighbouring linguistic domains explains the structural patterns observed. Our findings may be of interest in the development of models for language dynamics or regarding the propagation of cultural innovations. In relation to species distribution, they pose the question of whether the spatial features of species ranges share architecture, and eventually generating mechanism, with the distribution of human linguistic groups. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  9. Simulation study on dynamics model of two kinds of on-orbit soft-contact mechanism

    NASA Astrophysics Data System (ADS)

    Ye, X.; Dong, Z. H.; Yang, F.

    2018-05-01

    Aiming at the problem that the operating conditions of the space manipulator is harsh and the space manipulator could not bear the large collision momentum, this paper presents a new concept and technical method, namely soft contact technology. Based on ADAMS dynamics software, this paper compares and simulates the mechanism model of on-orbit soft-contact mechanism based on the bionic model and the integrated double joint model. The main purpose is to verify the path planning ability and the momentum buffering ability based on the different design concept mechanism. The simulation results show that both the two mechanism models have the path planning function before the space target contact, and also has the momentum buffer and controllability during the space target contact process.

  10. Registration of knee joint surfaces for the in vivo study of joint injuries based on magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Cheng, Rita W. T.; Habib, Ayman F.; Frayne, Richard; Ronsky, Janet L.

    2006-03-01

    In-vivo quantitative assessments of joint conditions and health status can help to increase understanding of the pathology of osteoarthritis, a degenerative joint disease that affects a large population each year. Magnetic resonance imaging (MRI) provides a non-invasive and accurate means to assess and monitor joint properties, and has become widely used for diagnosis and biomechanics studies. Quantitative analyses and comparisons of MR datasets require accurate alignment of anatomical structures, thus image registration becomes a necessary procedure for these applications. This research focuses on developing a registration technique for MR knee joint surfaces to allow quantitative study of joint injuries and health status. It introduces a novel idea of translating techniques originally developed for geographic data in the field of photogrammetry and remote sensing to register 3D MR data. The proposed algorithm works with surfaces that are represented by randomly distributed points with no requirement of known correspondences. The algorithm performs matching locally by identifying corresponding surface elements, and solves for the transformation parameters relating the surfaces by minimizing normal distances between them. This technique was used in three applications to: 1) register temporal MR data to verify the feasibility of the algorithm to help monitor diseases, 2) quantify patellar movement with respect to the femur based on the transformation parameters, and 3) quantify changes in contact area locations between the patellar and femoral cartilage at different knee flexion angles. The results indicate accurate registration and the proposed algorithm can be applied for in-vivo study of joint injuries with MRI.

  11. Impact of mechanism vibration characteristics by joint clearance and optimization design of its multi-objective robustness

    NASA Astrophysics Data System (ADS)

    Zeng, Baoping; Wang, Chao; Zhang, Yu; Gong, Yajun; Hu, Sanbao

    2017-12-01

    Joint clearances and friction characteristics significantly influence the mechanism vibration characteristics; for example: as for joint clearances, the shaft and bearing of its clearance joint collide to bring about the dynamic normal contact force and tangential coulomb friction force while the mechanism works; thus, the whole system may vibrate; moreover, the mechanism is under contact-impact with impact force constraint from free movement under action of the above dynamic forces; in addition, the mechanism topology structure also changes. The constraint relationship between joints may be established by a repeated complex nonlinear dynamic process (idle stroke - contact-impact - elastic compression - rebound - impact relief - idle stroke movement - contact-impact). Analysis of vibration characteristics of joint parts is still a challenging open task by far. The dynamic equations for any mechanism with clearance is often a set of strong coupling, high-dimensional and complex time-varying nonlinear differential equations which are solved very difficultly. Moreover, complicated chaotic motions very sensitive to initial values in impact and vibration due to clearance let high-precision simulation and prediction of their dynamic behaviors be more difficult; on the other hand, their subsequent wearing necessarily leads to some certain fluctuation of structure clearance parameters, which acts as one primary factor for vibration of the mechanical system. A dynamic model was established to the device for opening the deepwater robot cabin door with joint clearance by utilizing the finite element method and analysis was carried out to its vibration characteristics in this study. Moreover, its response model was carried out by utilizing the DOE method and then the robust optimization design was performed to sizes of the joint clearance and the friction coefficient change range so that the optimization design results may be regarded as reference data for selecting bearings

  12. Ankle joint pressure changes in a pes cavovarus model: supramalleolar valgus osteotomy versus lateralizing calcaneal osteotomy.

    PubMed

    Schmid, Timo; Zurbriggen, Sebastian; Zderic, Ivan; Gueorguiev, Boyko; Weber, Martin; Krause, Fabian G

    2013-09-01

    A fixed cavovarus foot deformity can be associated with anteromedial ankle arthrosis due to elevated medial joint contact stresses. Supramalleolar valgus osteotomies (SMOT) and lateralizing calcaneal osteotomies (LCOT) are commonly used to treat symptoms by redistributing joint contact forces. In a cavovarus model, the effects of SMOT and LCOT on the lateralization of the center of force (COF) and reduction of the peak pressure in the ankle joint were compared. A previously published cavovarus model with fixed hindfoot varus was simulated in 10 cadaver specimens. Closing wedge supramalleolar valgus osteotomies 3 cm above the ankle joint level (6 and 11 degrees) and lateral sliding calcaneal osteotomies (5 and 10 mm displacement) were analyzed at 300 N axial static load (half body weight). The COF migration and peak pressure decrease in the ankle were recorded using high-resolution TekScan pressure sensors. A significant lateral COF shift was observed for each osteotomy: 2.1 mm for the 6 degrees (P = .014) and 2.3 mm for the 11 degrees SMOT (P = .010). The 5 mm LCOT led to a lateral shift of 2.0 mm (P = .042) and the 10 mm LCOT to a shift of 3.0 mm (P = .006). Comparing the different osteotomies among themselves no significant differences were recorded. No significant anteroposterior COF shift was seen. A significant peak pressure reduction was recorded for each osteotomy: The SMOT led to a reduction of 29% (P = .033) for the 6 degrees and 47% (P = .003) for the 11 degrees osteotomy, and the LCOT to a reduction of 41% (P = .003) for the 5 mm and 49% (P = .002) for the 10 mm osteotomy. Similar to the COF lateralization no significant differences between the osteotomies were seen. LCOT and SMOT significantly reduced anteromedial ankle joint contact stresses in this cavovarus model. The unloading effects of both osteotomies were equivalent. More correction did not lead to significantly more lateralization of the COF or more reduction of peak pressure but a trend was

  13. Gene-expression changes in knee-joint tissues with aging and menopause: implications for the joint as an organ

    PubMed Central

    Rollick, Natalie C; Lemmex, Devin B; Ono, Yohei; Reno, Carol R; Hart, David A; Lo, Ian KY; Thornton, Gail M

    2018-01-01

    Background When considering the “joint as an organ”, the tissues in a joint act as complementary components of an organ, and the “set point” is the cellular activity for homeostasis of the joint tissues. Even in the absence of injury, joint tissues have adaptive responses to processes, like aging and menopause, which result in changes to the set point. Purpose The purpose of this study in a preclinical model was to investigate age-related and menopause-related changes in knee-joint tissues with the hypothesis that tissues will change in unique ways that reflect their differing contributions to maintaining joint function (as measured by joint laxity) and the differing processes of aging and menopause. Methods Rabbit knee-joint tissues from three groups were evaluated: young adult (gene expression, n=8; joint laxity, n=7; water content, n=8), aging adult (gene expression, n=6; joint laxity, n=7; water content, n=5), and menopausal adult (gene expression, n=8; joint laxity, n=7; water content, n=8). Surgical menopause was induced with ovariohysterectomy surgery and gene expression was assessed using reverse-transcription quantitative polymerase chain reaction. Results Aging resulted in changes to 37 of the 150 gene–tissue combinations evaluated, and menopause resulted in changes to 39 of the 150. Despite the similar number of changes, only eleven changes were the same in both aging and menopause. No differences in joint laxity were detected comparing young adult rabbits with aging adult rabbits or with menopausal adult rabbits. Conclusion Aging and menopause affected the gene-expression patterns of the tissues of the knee joint differently, suggesting unique changes to the set point of the knee. Interestingly, aging and menopause did not affect knee-joint laxity, suggesting that joint function was maintained, despite changes in gene expression. Taken together, these findings support the theory of the joint as an organ where the tissues of the joint adapt to

  14. Carrier Selective, Passivated Contacts for High Efficiency Silicon Solar Cells based on Transparent Conducting Oxides

    DOE PAGES

    Young, David L.; Nemeth, William; Grover, Sachit; ...

    2014-01-01

    We describe the design, fabrication and results of passivated contacts to n-type silicon utilizing thin SiO 2 and transparent conducting oxide layers. High temperature silicon dioxide is grown on both surfaces of an n-type wafer to a thickness <50 Å, followed by deposition of tin-doped indium oxide (ITO) and a patterned metal contacting layer. As deposited, the thin-film stack has a very high J0, contact, and a non-ohmic, high contact resistance. However, after a forming gas anneal, the passivation quality and the contact resistivity improve significantly. The contacts are characterized by measuring the recombination parameter of the contact (J0, contact)more » and the specific contact resistivity (ρ contact) using a TLM pattern. The best ITO/SiO 2 passivated contact in this study has J 0,contact = 92.5 fA/cm 2 and ρ contact = 11.5 mOhm-cm 2. These values are placed in context with other passivating contacts using an analysis that determines the ultimate efficiency and the optimal area fraction for contacts for a given set of (J0, contact, ρ contact) values. The ITO/SiO 2 contacts are found to have a higher J0, contact, but a similar ρ contact compared to the best reported passivated contacts.« less

  15. Atypical prefrontal cortical responses to joint/non-joint attention in children with autism spectrum disorder (ASD): A functional near-infrared spectroscopy study

    PubMed Central

    Zhu, Huilin; Li, Jun; Fan, Yuebo; Li, Xinge; Huang, Dan; He, Sailing

    2015-01-01

    Autism spectrum disorder (ASD) is a neuro-developmental disorder, characterized by impairments in one’s capacity for joint attention. In this study, functional near-infrared spectroscopy (fNIRS) was applied to study the differences in activation and functional connectivity in the prefrontal cortex between children with autism spectrum disorder (ASD) and typically developing (TD) children. 21 ASD and 20 TD children were recruited to perform joint and non-joint attention tasks. Compared with TD children, children with ASD showed reduced activation and atypical functional connectivity pattern in the prefrontal cortex during joint attention. The atypical development of left prefrontal cortex might play an important role in social cognition defects of children with ASD. PMID:25798296

  16. Decrease of contact resistance at the interface of carbon nanotube/electrode by nanowelding

    NASA Astrophysics Data System (ADS)

    Zhao, Bo; Wang, Yanfang; Zhang, Yafei

    2017-03-01

    Reliable interconnection between carbon nanotubes (CNTs) and external circuit is one of the prerequisite in CNT electronics. In this work, ultrasonic nanowelding was used to bond CNTs with metal electrodes. By exerting ultrasonic energy at the interface of CNT/electrode, a reliable joint with negligible contact resistance was obtained between CNTs and electrodes. The performance of welding is susceptible to the ultrasonic parameters such as ultrasonic power and clamping force, as well as the metal type. It is found that the metals with good ductility or low melting point are easier to achieve effective joints. Moreover, interfacial compounds are formed at the welded surface of metal Al and Fe, which is resulted from the interacting and chemical bonding of carbon and metal atoms. After nanowelding, the contact resistance between CNTs and electrode is decreased dramatically, and the two-terminal resistance of the sample approximates to the intrinsic resistance of the CNT itself.

  17. Mechanical Influences on Morphogenesis of the Knee Joint Revealed through Morphological, Molecular and Computational Analysis of Immobilised Embryos

    PubMed Central

    Roddy, Karen A.; Prendergast, Patrick J.; Murphy, Paula

    2011-01-01

    Very little is known about the regulation of morphogenesis in synovial joints. Mechanical forces generated from muscle contractions are required for normal development of several aspects of normal skeletogenesis. Here we show that biophysical stimuli generated by muscle contractions impact multiple events during chick knee joint morphogenesis influencing differential growth of the skeletal rudiment epiphyses and patterning of the emerging tissues in the joint interzone. Immobilisation of chick embryos was achieved through treatment with the neuromuscular blocking agent Decamethonium Bromide. The effects on development of the knee joint were examined using a combination of computational modelling to predict alterations in biophysical stimuli, detailed morphometric analysis of 3D digital representations, cell proliferation assays and in situ hybridisation to examine the expression of a selected panel of genes known to regulate joint development. This work revealed the precise changes to shape, particularly in the distal femur, that occur in an altered mechanical environment, corresponding to predicted changes in the spatial and dynamic patterns of mechanical stimuli and region specific changes in cell proliferation rates. In addition, we show altered patterning of the emerging tissues of the joint interzone with the loss of clearly defined and organised cell territories revealed by loss of characteristic interzone gene expression and abnormal expression of cartilage markers. This work shows that local dynamic patterns of biophysical stimuli generated from muscle contractions in the embryo act as a source of positional information guiding patterning and morphogenesis of the developing knee joint. PMID:21386908

  18. Contact lens rehabilitation following repaired corneal perforations

    PubMed Central

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  19. Contact dermatitis caused by tulips: identification of contact sensitizers in tulip workers of Kashmir Valley in North India.

    PubMed

    Hassan, Iffat; Rasool, Farhan; Akhtar, Saniya; Kamili, Afifa; Rather, Parvaiz; Kanth, Raihana; Bhat, Yasmeen; Rather, Shagufta; Mubashir, Syed; Yaseen, Atiya; Bashir, Safia

    2018-01-01

    Tulip, belonging to the genus Tulipa and family Liliaceae, is a spring-blooming perennial that grows from bulbs. Owing to manual handling, contact dermatitis can occur in professionals at any stage of the growth cycle of the tulip plant. To determine the clinical pattern of contact dermatitis resulting from tulip plant cultivation, and to assess contact allergy in workers coming into contact with this plant. One hundred and sixty-four tulip workers were screened, and 48 patients with suspected contact dermatitis were patch tested with 39 allergens, including haptens from the Indian baseline series, a plant series, and extracts from different parts of the tulip plant. Thirty-nine positive patch test reactions were observed in 21 patients. Seventeen patients showed positive reactions to either α-methylene-γ-butyrolactone or to tulip plant extract. Clinical relevance was observed for 13 of 17 positive patch test reactions. Contact dermatitis is an important health hazard in workers dealing with tulip bulbs. Further studies to identify and isolate other possible tulip allergens, and to quantify the amounts of allergens in different parts of the tulip plant, are recommended. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Videodermoscopy does not enhance diagnosis of scalp contact dermatitis due to topical minoxidil.

    PubMed

    Tosti, Antonella; Donati, Aline; Vincenzi, Colombina; Fabbrocini, Gabriella

    2009-07-01

    Videodermoscopy (VD) is a noninvasive diagnostic tool that provides useful information for the differential diagnosis of scalp disorders. The aim of this study was to investigate if dermoscopy may help the clinician in the diagnosis of contact dermatitis of the scalp. We analyzed the dermoscopic images taken from 7 patients with contact dermatitis due to topical minoxidil, 6 patients complaining of intense scalp itching during treatment with topical minoxidil but with negative patch tests and 19 controls. The following dermoscopic patterns described for scalp diseases were evaluated: Vascular patterns (simple loops, twisted loops and arborizing lines), follicular/perifollicular patterns (yellow dots, empty ostia, white dots, peripilar signs), white scales, yellow scales, follicular plugging, hair diameter diversity, honeycomb pattern and short regrowing hairs. Findings were graded from 0-4, according to severity in 20-fold magnifications. Statistical analysis included univariate analysis and Chi-square test by SPSS version 12. There were no statistical differences in the analysis of the vascular patterns and scales between the 3 groups. We were not able to detect dermoscopic features that can help the clinician in distinguishing scalp contact dermatitis due to topical minoxidil from other conditions that cause severe scalp itching. In particular, minoxidil contact dermatitis does not produce increase or alterations in the morphology of the scalp vessels or significant scalp scaling when evaluated with dermoscopy.