Sample records for joint fluid samples

  1. Culture - joint fluid

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003742.htm Culture - joint fluid To use the sharing features on this page, please enable JavaScript. Joint fluid culture is a laboratory test to detect infection-causing ...

  2. Increased concentrations of bone sialoprotein in joint fluid after knee injury.

    PubMed Central

    Lohmander, L S; Saxne, T; Heinegård, D

    1996-01-01

    OBJECTIVE: To detect evidence for localised changes in bone matrix metabolism after joint trauma and in post-traumatic osteoarthritis by quantification of bone sialoprotein in joint fluid and serum after knee injury in a cross sectional study. METHODS: Samples of knee joint fluid and serum were obtained from volunteers with normal knees (n = 19), patients with rupture of the anterior cruciate ligament isolated or combined with tear of a meniscus (n = 114), and patients with isolated meniscus lesions (n = 80). Concentrations of bone sialoprotein were determined by ELISA. Concentrations of other markers of joint tissue metabolism in these samples were determined in previous investigations. RESULTS: The median concentrations of bone sialoprotein in joint fluid from healthy volunteers was 122 ng ml-1 (range 41 to 183). Concentrations of bone sialoprotein were increased in both injury groups compared with the reference group (median for cruciate ligament injury 146 ng ml-1, range 72 to 339; median for meniscus injury 166 ng ml-1, range 75 to 376). After injury, bone sialoprotein increased quickly and remained increased for six months. Bone sialoprotein in joint fluid was increased only in samples from joints with normal or nearly normal (fibrillated) cartilage, and was within reference range in joints with radiographic signs of osteoarthritis. Bone sialoprotein concentrations in joints with cruciate ligament injury were positively correlated with levels of aggrecan and cartilage oligomeric matrix protein fragments, and with levels of stromelysin-1 and tissue inhibitor of metalloproteinase-1. The ratios between the concentrations of bone sialoprotein in joint fluid and serum were > 1 in the majority of the cruciate ligament injury cases. CONCLUSIONS: The release of significant amounts of bone sialoprotein into joint fluid in connection with acute joint trauma may be associated with injury to, and active remodelling of, the cartilage-bone interface and subchondral bone

  3. Expression of proteins in serum, synovial fluid, synovial membrane, and articular cartilage samples obtained from dogs with stifle joint osteoarthritis secondary to cranial cruciate ligament disease and dogs without stifle joint arthritis.

    PubMed

    Garner, Bridget C; Kuroki, Keiichi; Stoker, Aaron M; Cook, Cristi R; Cook, James L

    2013-03-01

    To identify proteins with differential expression between healthy dogs and dogs with stifle joint osteoarthritis secondary to cranial cruciate ligament (CCL) disease. Serum and synovial fluid samples obtained from dogs with stifle joint osteoarthritis before (n = 10) and after (8) surgery and control dogs without osteoarthritis (9) and archived synovial membrane and articular cartilage samples obtained from dogs with stifle joint osteoarthritis (5) and dogs without arthritis (5). Serum and synovial fluid samples were analyzed via liquid chromatography-tandem mass spectrometry; results were compared against a nonredundant protein database. Expression of complement component 3 in archived tissue samples was determined via immunohistochemical methods. No proteins had significantly different expression between serum samples of control dogs versus those of dogs with stifle joint osteoarthritis. Eleven proteins (complement component 3 precursor, complement factor I precursor, apolipoprotein B-100 precursor, serum paraoxonase and arylesterase 1, zinc-alpha-2-glycoprotein precursor, serum amyloid A, transthyretin precursor, retinol-binding protein 4 precursor, alpha-2-macroglobulin precursor, angiotensinogen precursor, and fibronectin 1 isoform 1 preproprotein) had significantly different expression (> 2.0-fold) between synovial fluid samples obtained before surgery from dogs with stifle joint osteoarthritis versus those obtained from control dogs. Complement component 3 was strongly expressed in all (5/5) synovial membrane samples of dogs with stifle joint osteoarthritis and weakly expressed in 3 of 5 synovial membrane samples of dogs without stifle joint arthritis. Findings suggested that the complement system and proteins involved in lipid and cholesterol metabolism may have a role in stifle joint osteoarthritis, CCL disease, or both.

  4. Analysis of synovial fluid of the Capybara's stifle joints.

    PubMed

    Brombini, Giovanna C; Rahal, Sheila C; Bergamini, Bruno C S; Lopes, Raimundo S; Santos, Ivan F C; Schimming, Bruno C

    2017-03-01

    Although normal synovial fluid has been well characterized in domestic animals such as dogs, cats, horses, and cows, the available information on larger rodents is scarce. The purpose of the study was to analyze the physical, chemical, and cytologic characteristics of the synovial fluid in stifle joints of Capybaras. Five free-ranging adult female Capybaras (Hydrochoerus hydrochaeris), weighing from 37 to 56 kg were used. Synovial fluid was obtained by aspiration of 10 stifle joints. Samples were analyzed for physical, chemical, and cytologic properties. Spontaneous clotting was negative in 9 samples. Most synovial fluids had pH 8, and protein concentrations ranged from 1.6 to 3.6 g/dL. The mucin clot test was good in all 6 samples that were tested. Nucleated cell counts ranged from 140 to 508 cells/μL. Relative differential leukocyte counts demonstrated a predominance of mononuclear cells (97.6%), including 76.2% undifferentiated mononuclear cells, 18.1% macrophages, and 3.66% lymphocytes. Polymorphonuclear cells included 1.83% neutrophils and 0.2% eosinophils. The synovial stifle joint fluid of healthy free-ranging adult Capybaras is clear, colorless, viscous, and with chemical features and cytologic findings similar to those seen in domestic animals. © 2017 American Society for Veterinary Clinical Pathology.

  5. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  6. The John Charnley Award Paper. The role of joint fluid in the tribology of total joint arthroplasty.

    PubMed

    Mazzucco, Daniel; Spector, Myron

    2004-12-01

    The effect of joint fluid on the tribology (ie, lubrication, friction, and wear) of total hip arthroplasty has not yet been investigated adequately. In the current study, a friction assay was used to assess four hypotheses relating to the effect of human joint fluid and its principal components on the articulation of metal-on-polyethylene. First, joint fluid was found to produce a widely varying amount of friction between cobalt-chromium and polyethylene; this range exceeded the range produced when the articulation was lubricated by water or bovine serum. Second, it was shown that hyaluronic acid, phospholipid, albumin, and gamma-globulin were not acting as boundary lubricants, but that one or more other proteins (as yet unidentified) were responsible for reducing friction in this couple. Third, lower friction was found when oxidized zirconium alloy replaced cobalt-chromium as a bearing surface on polyethylene. Finally, a pilot study suggested that lubricin, which contributes to cartilage-on-cartilage lubrication, is not a protein responsible for the tribological variabiation found among joint fluid samples. The current study showed that joint fluid is a patient factor that influences the tribology of metal-on-polyethylene arthroplasty.

  7. [Viscosity determination of synovial fluids from the canine hip and elbow joint as well as the human knee joint].

    PubMed

    Helms, Gabriele; Rittmann, Pia; Wefstaedt, Patrick; Windhagen, Henning; Pressel, Thomas; Behrens, Bernd-Arno; Nolte, Ingo

    2008-01-01

    The development of pathological changes in both human and canine hip joints is mainly caused by a lack of synovial fluid lubrication. This results in an increased joint abrasion. Even after implantation of joint prosthesis, inadequate lubrication can lead to abrasion in the tribological pair. This can finally result in aseptic loosening of the prosthesis. In spite of the enormous number of studies that have been performed on human, only little knowledge about the tribological properties of the joints in dogs is available in the literature. For this reason the viscosities of synovial fluid, derived from physiological and pathologically changed canine elbow joints were measured. The viscosities were determined by the use of a cone-plate viscometer at different temperatures and shear rates. The obtained values were compared with the viscosity values of pathologically changed synovial fluids from human knee joints as well as with pathological samples from the canine hip joint. The results show that the viscosity values vary within a series of measurements and are inversely proportional to the temperature of the sample and the shear rate. The differences between the average viscosities of canine and human synovial fluids taken from pathologically changed joints are below 4% (22.5 s(-1) at theta1 = 25 degrees C). The findings of this study are being implemented in a FE-Model for the computation of actual forces in the hip joint during different movements. This would represent a contribution to an improved prosthetic treatment of canine and human hips.

  8. Ceramic debris in hip prosthesis: correlation between synovial fluid and joint capsule.

    PubMed

    De Pasquale, Dalila; Stea, Susanna; Beraudi, Alina; Montesi, Monica; Squarzoni, Stefano; Toni, Aldo

    2013-05-01

    Detection of ceramic particles in synovial fluids allows early diagnosis of ceramic damage, but there is no evidence of a relationship between ceramic debris in the articular space and in the joint capsule. The aim of the present study is to verify if the particles isolated in the synovial fluid are comparable with those stored in the capsular tissue. Twenty-one patients were enrolled. Both synovial fluid and capsular samples were collected during revision surgery and ceramic particles were isolated and analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis. It resulted a significant correlation between the samples couples (18 out of 21). This study confirms that the synovial fluid analysis can give a clear definition of the presence of particles in the joint capsule. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Interleukin-8 mRNA expression in synovial fluid of canine stifle joints with osteoarthritis.

    PubMed

    de Bruin, T; de Rooster, H; van Bree, H; Cox, E

    2005-12-15

    The objective of this study was to examine and compare the presence of interleukin (IL)-8 mRNA in canine stifle osteoarthritis (OA) differing in etiopathogenesis. Synovial fluid (SF) samples were collected from 24 clinically normal stifle joints and 46 diseased stifle joints (32 stifle joints with cranial cruciate ligament rupture (CCLR), 2 joints with CCLR and patella luxation (PL), 7 joints with medial PL and 5 joints with primary OA). The samples were centrifuged to collect synovial fluid cells for RNA extraction. Reverse transcription polymerase chain reaction (RT-PCR) was performed to obtain cDNA from all samples. Canine IL-8 mRNA expression was determined using real time PCR. Synovial fluid glass smears were made of all samples and coloured with H&E for differential cell counts. All stifle joints were radiographed and graded for the severity of OA. Sixty-one percent (28/46) of the samples from canine stifle OA had IL-8 mRNA expression in contrast to 4% (1/24) in the control stifle joints. This difference in prevalence is highly significant. There were no statistically significant pairwise differences among the mean ranks of the various OA groups for the absolute amount of IL-8 mRNA expression. Neither was there a link between the severity of OA (determined by radiographic evaluation) and the presence of IL-8 in the SF nor any significant difference in the absolute amount of IL-8 between the different OA grades. No statistical difference was found in differential cell counts between IL-8-positive and -negative SF samples. IL-8 cannot be used as a specific joint disease marker since IL-8 expression is found in OA differing in etiopathogenesis. It might, however, relate to the ongoing inflammation within the joint.

  10. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    2000-01-01

    A fluid-sampling tool for obtaining a fluid sample from a container. When used in combination with a rotatable drill, the tool bores a hole into a container wall, withdraws a fluid sample from the container, and seals the borehole. The tool collects fluid sample without exposing the operator or the environment to the fluid or to wall shavings from the container.

  11. Fluid sampling device

    NASA Technical Reports Server (NTRS)

    Studenick, D. K. (Inventor)

    1977-01-01

    An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.

  12. The Effects of Fluid Absorption on the Mechanical Properties of Joint Prostheses Components

    NASA Astrophysics Data System (ADS)

    Yarbrough, David; Viano, Ann

    2010-02-01

    Ultra-high-molecular-weight polyethylene (UHMWPE) is the material playing the role of cartilage in human prosthetic joints. Wear debris from UHMWPE is a common reason for joint arthroplasty failure, and the exact mechanism responsible for wear remains an area of investigation. In this study, the microstructure of UHMWPE was examined as a function of fluid absorption. Samples with varying exposure to e-beam radiation (as part of the manufacturing process) were soaked for forty days in saline or artificial synovial fluid, under zero or 100 lbs load. Samples were then tensile-tested according to ASTM D-3895. The post-stressed material was then examined by transmission electron microscopy to evaluate the molecular response to stress, which correlates with macroscopic mechanical properties. Three parameters of the crystalline lamellae were measured: thickness, stacking ratio, and alignment to stress direction. Results indicate that fluid absorption does affect the mechanical properties of UHMWPE at both the microscopic and microscopic levels. )

  13. Use of proteomic analysis to determine the protein constituents of synovial fluid samples from the stifle joints of dogs with and without osteoarthritis secondary to cranial cruciate ligament rupture.

    PubMed

    Shahid, Muhammad; Manchi, George; Brunnberg, Leo; Raila, Jens

    2018-04-01

    OBJECTIVE To use proteomic analysis to determine the protein constituents of synovial fluid samples from the stifle joints of dogs with and without osteoarthritis secondary to cranial cruciate ligament rupture (CCLR). ANIMALS 12 dogs with clinically normal stifle joints (controls) and 16 dogs with osteoarthritis secondary to CCLR. PROCEDURES A synovial fluid sample was obtained from all dogs. Synovial fluid total protein concentration was determined by the Bradford assay. Proteins were separated by use of a 1-D SDS-PAGE to detect protein bands that differed between dogs with and without osteoarthritis. Those protein bands then underwent trypsin digestion and were analyzed by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry, the results of which were compared with a curated protein sequence database for protein identification. One of the most frequently identified proteins, apoprotein (apo) A-I, was then quantified in all synovial fluid samples by use of a competitive-inhibition ELISA. Results were compared between dogs with and without osteoarthritis. RESULTS Median synovial fluid total protein and apo A-I concentrations for dogs with osteoarthritis were significantly greater than those for control dogs. The most abundant proteins identified in the synovial fluid were albumin and apo A-I. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that quantification of synovial fluid total protein and apo A-I concentrations might facilitate diagnosis of osteoarthritis secondary to CCLR in dogs. Further research and validation of synovial fluid apo A-I concentration as a biomarker for osteoarthritis in dogs are necessary before it can be recommended for clinical use.

  14. [Analysis of factors related to the number of mesenchymal stem cells derived from synovial fluid of the temporomandibular joint].

    PubMed

    Sun, Y P; Zheng, Y H; Zhang, Z G

    2017-06-09

    Objective: To analyze related factors on the number of mesenchymal stem cells in the synovial fluid of the temporomandibular joint (TMJ) and provide an research basis for understanding of the source and biological role of mesenchymal stem cells derived from synovial fluid in TMJ. Methods: One hundred and twenty-two synovial fluid samples from 91 temporomandibular disorders (TMD) patients who visited in Department of TMJ Center, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University from March 2013 to December 2013 were collected in this study, and 6 TMJ synovial fluid samples from 6 normal volunteers who were studying in the North Campus of Sun Yat-sen University were also collected, so did their clinical information. Then the relation between the number of mesenchymal stem cells derived from synovial fluid and the health status of the joints, age of donor, disc perforation, condylar bony destruction, blood containing and visual analogue scale score of pain were investigated using Mann-Whitney U test and Spearman rank correlation test. Results: The number of mesenchymal stem cells derived from synovial fluid had no significant relation with visual analogue scale score of pain ( r= 0.041, P= 0.672), blood containing ( P= 0.063), condylar bony destruction ( P= 0.371). Linear correlation between the number of mesenchymal stem cells derived from synovial fluid and age of donor was very week ( r= 0.186, P= 0.043). The number of mesenchymal stem cells up-regulated when the joint was in a disease state ( P= 0.001). The disc perforation group had more mesenchymal stem cells in synovial fluid than without disc perforation group ( P= 0.042). Conclusions: The number of mesenchymal stem cells derived from synovial fluid in TMJ has no correlation with peripheral blood circulation and condylar bony destruction, while has close relation with soft tissue structure damage of the joint.

  15. Evaluation of anticollagen type I antibody titers in synovial fluid of both stifle joints and the left shoulder joint of dogs with unilateral cranial cruciate disease.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2007-03-01

    To evaluate anticollagen type I antibodies in synovial fluid of the affected stifle joint, the contralateral stifle joint, and the left shoulder joint of dogs with unilateral cranial cruciate ligament (CrCL) rupture during an extended period of 12 to 18 months. 13 client-owned dogs with CrCL rupture and 2 sham-operated dogs. All dogs were examined and arthrocentesis of all 3 joints was performed every 6 months after surgery. Synovial fluid samples were tested for anticollagen type I antibodies by use of an ELISA. Dogs with partial CrCL rupture had higher antibody titers than dogs with complete rupture. Six of 13 dogs ruptured the contralateral CrCL during the study, whereby higher antibody titers were found for the stifle joints than for the shoulder joint. Seronegative dogs or dogs with extremely low antibody titers and 2 dogs with high antibody titers did not sustain a CrCL rupture in the contralateral stifle joint. In most dogs that had a CrCL rupture of the contralateral stifle joint, a distinct antibody titer gradient toward the stifle joints was detected, suggesting that there was a local inflammatory process in these joints. However, only a small number of sham-operated dogs were used to calculate the cutoff values used to determine the anticollagen type I antibody titers in these patients. Synovial fluid antibodies against collagen type I alone do not initiate CrCL rupture because not all dogs with high antibody titers sustained a CrCL rupture in the contralateral stifle joint.

  16. Gelatinase activity in synovial fluid and synovium obtained from healthy and osteoarthritic joints of dogs.

    PubMed

    Volk, Susan W; Kapatkin, Amy S; Haskins, Mark E; Walton, Raquel M; D'Angelo, Marina

    2003-10-01

    To determine matrix metalloproteinase (MMP) activity in synovial fluid (SF) obtained from the joints of dogs with degenerative joint disease (DJD) secondary to various underlying conditions. 35 samples of SF obtained from 18 clinically normal (control) dogs and 34 samples of SF obtained from 17 dogs with DJD; dogs with DJD were from 2 populations (client-owned dogs and research dogs that had DJD secondary to the lysosomal storage disease mucopolysaccharidosis VII). MMP activity in samples of SF was semiquantitatively examined by use of gelatin or casein zymography. Western blot analysis was performed by use of antibodies for MMP-2 and MMP-9. In addition, in situ MMP activity was observed in sections of synovial membrane obtained from healthy and osteoarthritic joints. Samples of SF from osteoarthritic joints had higher MMP-2 activity and dramatically increased MMP-9 activity, compared with values for healthy joints. Substrate-overlay analyses indicated minimal gelatin-degrading activity in synoviocytes obtained from control dogs, whereas greater activity was seen in osteoarthritic synoviocytes, with additional activity in the underlying tissue. Higher MMP-2 activity and dramatic increases in MMP-9 activity were associated with the osteoarthritic state, even though MMP-2 activity was detected in healthy joints. This study expands information on MMP production in SF of osteoarthritic joints in other species and documents the similarity of MMP activity patterns regardless of the cause of DJD.

  17. Coupled Viscous Fluid Flow and Joint Deformation Analysis for Grout Injection in a Rock Joint

    NASA Astrophysics Data System (ADS)

    Kim, Hyung-Mok; Lee, Jong-Won; Yazdani, Mahmoud; Tohidi, Elham; Nejati, Hamid Reza; Park, Eui-Seob

    2018-02-01

    Fluid flow modeling is a major area of interest within the field of rock mechanics. The main objective of this study is to gain insight into the performance of grout injection inside jointed rock masses by numerical modeling of grout flow through a single rock joint. Grout flow has been widely simulated using non-Newtonian Bingham fluid characterized by two main parameters of dynamic viscosity and shear yield strength both of which are time dependent. The increasing value of these properties with injection time will apparently affect the parameters representing the grouting performance including grout penetration length and volumetric injection rate. In addition, through hydromechanical coupling a mutual influence between the injection pressure from the one side and the joint opening/closing behavior and the aperture profile variation on the other side is anticipated. This is capable of producing a considerable impact on grout spread within the rock joints. In this study based on the Bingham fluid model, a series of numerical analysis has been conducted using UDEC to simulate the flow of viscous grout in a single rock joint with smooth parallel surfaces. In these analyses, the time-dependent evolution of the grout fluid properties and the hydromechanical coupling have been considered to investigate their impact on grouting performance. In order to verify the validity of these simulations, the results of analyses including the grout penetration length and the injection flow rate were compared with a well-known analytical solution which is available for the simple case of constant grout properties and non-coupled hydraulic analysis. The comparison demonstrated that the grout penetration length can be overestimated when the time-dependent hardening of grout material is not considered. Moreover, due to the HM coupling, it was shown that the joint opening induced by injection pressure may have a considerable increasing impression on the values of penetration length and

  18. Examination of synovial fluid hyaluronan quantity and quality in stifle joints of dogs with osteoarthritis.

    PubMed

    Venable, Rachel O; Stoker, Aaron M; Cook, Cristi R; Cockrell, Mary K; Cook, James L

    2008-12-01

    To determine the quantity (concentration) and quality (molecular weight) of synovial fluid hyaluronan with respect to presence and severity of osteoarthritis in stifle joints of dogs. 21 purpose-bred dogs and 6 clinically affected large-breed dogs (cranial cruciate ligament [CrCL] disease with secondary osteoarthritis). Research dogs underwent arthroscopic surgery in 1 stifle joint to induce osteoarthritis via CrCL transection (CrCLt; n=5 stifle joints), femoral condylar articular cartilage groove creation (GR; 6), or meniscal release (MR; 5); 5 had sham surgery (SH) performed. Contralateral stifle joints (n=21) were used as unoperated control joints. Synovial fluid was obtained from research dogs at time 0 and 12 weeks after surgery and from clinically affected dogs prior to surgery. All dogs were assessed for lameness, radiographic signs of osteoarthritis, and pathologic findings on arthroscopy as well as for quantity and quality of hyaluronan. Clinically affected dogs had significantly greater degrees of pathologic findings, compared with dogs with surgically induced osteoarthritis (ie, those with CrCLt, GR, and MR stifle joints), and with respect to lameness scores, radiographic signs of osteoarthritis, pathologic findings on arthroscopy, and synovial fluid hyaluronan concentration. Synovial fluid from stifle joints of dogs with surgically induced osteoarthritis had hyaluronan bands at 35 kd on western blots that synovial fluid from SH and clinically affected stifle joints did not. Synovial fluid hyaluronan quantity and quality were altered in stifle joints of dogs with osteoarthritis, compared with control stifle joints. A specific hyaluronan protein fragment may be associated with early pathologic changes in affected joints.

  19. Fluid sampling tool

    DOEpatents

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    1999-05-25

    A fluid sampling tool for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall.

  20. Interstitial matrix proteins determine hyaluronan reflection and fluid retention in rabbit joints: effect of protease

    PubMed Central

    Sabaratnam, S; Coleman, P J; Mason, R M; Levick, J R

    2007-01-01

    Hyaluronan (HA) retention inside the synovial cavity of joints serves diverse protective roles. We tested the hypothesis that HA retention is mediated by the network of extracellular matrix proteins in the synovial lining. Cannulated rabbit knee joints were infused with HA solution with or without pretreatment by chymopapain, a collagen-sparing protease. Trans-synovial fluid escape rate was measured and, after a period of trans-synovial filtration, samples of intra-articular fluid and subsynovial fluid were analysed for HA to assess its trans-synovial ultrafiltration. In control joints, HA ultrafiltration was confirmed by postfiltration increases in intra-articular HA concentration (259 ± 17% of infused concentration) and reduced subsynovial concentration (30 ± 8%; n = 11). The proportion of HA molecules reflected by the synovium was 57–75%. Chymopapain treatment increased the hydraulic permeability of the synovial lining ∼13-fold, almost abolished the trans-synovial difference in HA concentration and reduced the HA reflected fraction to 3–7% (n = 6; P < 0.001, ANOVA). Structural studies confirmed that chymopapain treatment depleted the matrix of proteoglycans but preserved its collagen. The findings thus demonstrate that HA ultrafiltration and synovial hydraulic permeability are determined by the network of non-collagen, extracellular matrix proteins. This may be important clinically, since protease activity is raised in rheumatoid arthritis, as are HA and fluid escape. PMID:17008373

  1. Quick bacteriophage-mediated bioluminescence assay for detecting Staphylococcus spp. in sonicate fluid of orthopaedic artificial joints.

    PubMed

    Šuster, Katja; Podgornik, Aleš; Cör, Andrej

    2017-07-01

    Staphylococcus spp. accounts for up to two thirds of all microorganisms causing prosthetic joint infections, with Staphylococcus aureus and Staphylococcus epidermidis being the major cause. The present study describes a diagnostic model to detect staphylococci using a specific bacteriophage and bioluminescence detection, exploring the possibility of its use on sonicate fluid of orthopaedic artificial joints. Intracellular adenosine-5'-triphosphate release by bacteriophage mediated lysis of staphylococci was assessed to determine optimal parameters for detection. With the optimized method, a limit of detection of around 103 CFU/mL was obtained after incubation with bacteriophage for 2 h. Importantly, sonicate fluid did not prevent the ability of bacteriophage to infect bacteria and all simulated infected sonicate fluid as well as 6 clinical samples with microbiologically proven staphylococcal infection were detected as positive. The total assay took approximately 4 h. Collectively, the results indicate that the developed method promises a rapid, inexpensive and specific diagnostic detection of staphylococci in sonicate fluid of infected prosthetic joints. In addition, the unlimited pool of different existing bacteriophages, with different specificity for all kind of bacteria gives the opportunity for further investigations, improvements of the current model and implementation in other medical fields for the purpose of the establishment of a rapid diagnosis.

  2. Fluid sampling tool

    DOEpatents

    Garcia, A.R.; Johnston, R.G.; Martinez, R.K.

    1999-05-25

    A fluid sampling tool is described for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall. 6 figs.

  3. Interleukin-6 in serum and in synovial fluid enhances the differentiation between periprosthetic joint infection and aseptic loosening.

    PubMed

    Randau, Thomas M; Friedrich, Max J; Wimmer, Matthias D; Reichert, Ben; Kuberra, Dominik; Stoffel-Wagner, Birgit; Limmer, Andreas; Wirtz, Dieter C; Gravius, Sascha

    2014-01-01

    The preoperative differentiation between septic and aseptic loosening after total hip or knee arthroplasty is essential for successful therapy and relies in part on biomarkers. The objective of this study was to assess synovial and serum levels of inflammatory proteins as diagnostic tool for periprosthetic joint infection and compare their accuracy with standard tests. 120 patients presenting with a painful knee or hip endoprosthesis for surgical revision were included in this prospective trial. Blood samples and samples of intraoperatively acquired joint fluid aspirate were collected. White blood cell count, C-reactive protein, procalcitonin and interleukin-6 were determined. The joint aspirate was analyzed for total leukocyte count and IL-6. The definite diagnosis of PJI was determined on the basis of purulent synovial fluid, histopathology and microbiology. IL-6 in serum showed significantly higher values in the PJI group as compared to aseptic loosening and control, with specificity at 58.3% and a sensitivity of 79.5% at a cut-off value of 2.6 pg/ml. With a cut-off >6.6 pg/ml, the specificity increased to 88.3%. IL-6 in joint aspirate had, at a cut-off of >2100 pg/ml, a specificity of 85.7% and sensitivity of 59.4%. At levels >9000 pg/ml, specificity was almost at 100% with sensitivity just below 50%, so PJI could be considered proven with IL-6 levels above this threshold. Our data supports the published results on IL-6 as a biomarker in PJI. In our large prospective cohort of revision arthroplasty patients, the use of IL-6 in synovial fluid appears to be a more accurate marker than either the white blood cell count or the C-reactive protein level in serum for the detection of periprosthetic joint infection. On the basis of the results we recommend the use of the synovial fluid biomarker IL-6 for the diagnosis of periprosthetic joint infection following total hip and knee arthroplasty.

  4. Tenascin-C levels in synovial fluid are elevated after injury to the human and canine joint and correlate with markers of inflammation and matrix degradation.

    PubMed

    Chockalingam, P S; Glasson, S S; Lohmander, L S

    2013-02-01

    We have previously shown the capacity of tenascin-C (TN-C) to induce inflammatory mediators and matrix degradation in vitro in human articular cartilage. The objective of the present study was to follow TN-C release into knee synovial fluid after acute joint injury or in joint disease, and to correlate TN-C levels with markers of cartilage matrix degradation and inflammation. Human knee synovial fluid samples (n = 164) were from a cross-sectional convenience cohort. Diagnostic groups were knee healthy reference, knee anterior cruciate ligament rupture, with or without concomitant meniscus lesions, isolated knee meniscus injury, acute inflammatory arthritis (AIA) and knee osteoarthritis (OA). TN-C was measured in synovial fluid samples using an enzyme-linked immunosorbent assay (ELISA) and results correlated to other cartilage markers. TN-C release was also monitored in joints of dogs that underwent knee instability surgery. Statistically significantly higher levels of TN-C compared to reference subjects were observed in the joint fluid of all human disease groups and in the dogs that underwent knee instability surgery. Statistically significant correlations were observed between the TN-C levels in the synovial fluid of the human patients and the levels of aggrecanase-dependent Ala-Arg-Gly-aggrecan (ARG-aggrecan) fragments and matrix metalloproteinases 1 and 3. We find highly elevated levels of TN-C in human knee joints after injury, AIA or OA that correlated with markers of cartilage degradation and inflammation. TN-C in synovial fluid may serve dual roles as a marker of joint damage and a stimulant of further joint degradation. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  5. Fluid sampling tool

    DOEpatents

    Johnston, Roger G.; Garcia, Anthony R. E.; Martinez, Ronald K.

    2001-09-25

    The invention includes a rotatable tool for collecting fluid through the wall of a container. The tool includes a fluid collection section with a cylindrical shank having an end portion for drilling a hole in the container wall when the tool is rotated, and a threaded portion for tapping the hole in the container wall. A passageway in the shank in communication with at least one radial inlet hole in the drilling end and an opening at the end of the shank is adapted to receive fluid from the container. The tool also includes a cylindrical chamber affixed to the end of the shank opposite to the drilling portion thereof for receiving and storing fluid passing through the passageway. The tool also includes a flexible, deformable gasket that provides a fluid-tight chamber to confine kerf generated during the drilling and tapping of the hole. The invention also includes a fluid extractor section for extracting fluid samples from the fluid collecting section.

  6. Markers of cartilage and synovial metabolism in joint fluid and serum of patients with chondromalacia of the patella.

    PubMed

    Väätäinen, U; Lohmander, L S; Thonar, E; Hongisto, T; Agren, U; Rönkkö, S; Jaroma, H; Kosma, V M; Tammi, M; Kiviranta, I

    1998-03-01

    To further our understanding of the pathogenesis of chondromalacia of the patella (CM), we have studied the release into knee joint fluid and serum, obtained from patients with CM, of molecules associated with the metabolism of joint cartilage matrix and synovium. Interleukin-1 alpha (IL-1 alpha), interleukin-1 beta (IL-1 beta), interleukin-6 (IL-6), stromelysin-1 (MMP-3), interstitial collagenase (MMP-1), tissue inhibitor for metalloproteinases-1 (TIMP-1), phospholipase activity A2 (PLA2), hyaluronan (HA), aggrecan fragments (AGN) and antigenic keratan sulfate (KS) were quantified in knee joint lavage fluid from 96 patients with CM; KS and HA also was measured in serum. Chondromalacia was graded on a scale of I to IV according to Outerbridge (1961). The histopathology of the synovial membrane close to the patellofemoral joint was evaluated. Control samples were obtained from nine patients with knee pain presenting with arthroscopically normal knee joints. The concentrations of MMP-3, MMP-1 and TIMP-1 proteins in joint lavage fluid were increased in advanced (grade IV) CM, compared with controls. Levels of MMP-1 in lavage fluid correlated with the severity of CM (r = 0.38, P < 0.01) and MMP-1 and MMP-3 concentrations correlated with each other (r = 0.45, P < 0.001). TIMP-1 was elevated in grade IV CM compared with grades II and III CM (P < 0.02, P < 0.01). Interleukins (IL-1 alpha, IL-1 beta and IL-6) showed no significant change in CM. The lavage fluid level of PLA2 increased with the severity of CM (r = 0.40, P < 0.001). Serum KS was higher in CM IV than in controls (P = 0.05), while lavage fluid KS concentration was elevated in CM I (P = 0.04). There were no differences in the lavage fluid levels of AGN and HA between the different study groups. Synovium showed slight or moderate histological signs of inflammation in 9% of CM patients. The changes in the release and activity of these marker molecules from serum and synovial fluid may reflect changes in the

  7. Effects of radiofrequency probe application on irrigation fluid temperature in the wrist joint.

    PubMed

    Sotereanos, Dean G; Darlis, Nickolaos A; Kokkalis, Zinon T; Zanaros, George; Altman, Gregory T; Miller, Mark Carl

    2009-12-01

    Radiofrequency (RF) probes used in wrist arthroscopy may raise joint fluid temperature, increasing the risk of capsular and ligamentous damage. The purposes of the current study were to measure joint fluid temperature during wrist arthroscopy with the use of RF probes, and to determine whether using an outlet portal will reduce the maximum temperature. We performed wrist arthroscopy on 8 cadaveric arms. Ablation and coagulation cycles using RF probe were performed at documented locations within the joint. This was done for 60-second intervals on both the radial and ulnar side of the wrist, to mimic clinical practice. We used 4 fiberoptic phosphorescent probes to measure temperature (radial, ulnar, inflow-tube, and outflow-tube probes) and measured joint fluid temperature with and without outflow. There was a significant difference between wrists with and without outflow when examining maximum ablation temperatures (p < .002). All specimens showed higher maximum and average ablation temperatures without outflow. Maximum joint temperatures, greater than 60 degrees C, were observed in only no-outflow conditions. In performing RF ablation during wrist arthroscopy, the use of an outlet portal reduces the joint fluid temperature. Without an outlet portal, maximum temperatures can exceed desirable levels when using ablation; such temperatures have the potential to damage adjacent tissues. It is useful to maintain adequate outflow when using the radiofrequency probes during wrist arthroscopy.

  8. Fluid sampling system for a nuclear reactor

    DOEpatents

    Lau, Louis K.; Alper, Naum I.

    1994-01-01

    A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump.

  9. Fluid sampling system for a nuclear reactor

    DOEpatents

    Lau, L.K.; Alper, N.I.

    1994-11-22

    A system of extracting fluid samples, either liquid or gas, from the interior of a nuclear reactor containment utilizes a jet pump. To extract the sample fluid, a nonradioactive motive fluid is forced through the inlet and discharge ports of a jet pump located outside the containment, creating a suction that draws the sample fluid from the containment through a sample conduit connected to the pump suction port. The mixture of motive fluid and sample fluid is discharged through a return conduit to the interior of the containment. The jet pump and means for removing a portion of the sample fluid from the sample conduit can be located in a shielded sample grab station located next to the containment. A non-nuclear grade active pump can be located outside the grab sampling station and the containment to pump the nonradioactive motive fluid through the jet pump. 1 fig.

  10. Probe for Sampling of Interstitial Fluid From Bone

    NASA Technical Reports Server (NTRS)

    Janle, Elsa M.

    2004-01-01

    An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.

  11. Focal cartilage defect compromises fluid-pressure dependent load support in the knee joint.

    PubMed

    Dabiri, Yaghoub; Li, LePing

    2015-06-01

    A focal cartilage defect involves tissue loss or rupture. Altered mechanics in the affected joint may play an essential role in the onset and progression of osteoarthritis. The objective of the present study was to determine the compromised load support in the human knee joint during defect progression from the cartilage surface to the cartilage-bone interface. Ten normal and defect cases were simulated with a previously tested 3D finite element model of the knee. The focal defects were considered in both condyles within high load-bearing regions. Fluid pressurization, anisotropic fibril-reinforcement, and depth-dependent mechanical properties were considered for the articular cartilages and menisci. The results showed that a small cartilage defect could cause 25% reduction in the load support of the knee joint due to a reduced capacity of fluid pressurization in the defect cartilage. A partial-thickness defect could cause a fluid pressure decrease or increase in the remaining underlying cartilage depending on the defect depth. A cartilage defect also increased the shear strain at the cartilage-bone interface, which was more significant with a full-thickness defect. The effect of cartilage defect on the fluid pressurization also depended on the defect sites and contact conditions. In conclusion, a focal cartilage defect causes a fluid-pressure dependent load reallocation and a compromised load support in the joint, which depend on the defect depth, site, and contact condition. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Treatment with unsaponifiable extracts of avocado and soybean increases TGF-beta1 and TGF-beta2 levels in canine joint fluid.

    PubMed

    Altinel, Levent; Saritas, Z Kadir; Kose, Kamil Cagri; Pamuk, Kamuran; Aksoy, Yusuf; Serteser, Mustafa

    2007-02-01

    Avocado and soya unsaponifiables (ASU) are plant extracts used as a slow-acting antiarthritic agent. ASU stimulate the synthesis of matrix components by chondrocytes, probably by increasing the production of transforming growth factor-beta (TGF-beta). TGF-beta is expressed by chondrocytes and osteoblasts and is present in cartilage matrix. This study investigates the effect of ASU treatment on the levels of two isoforms of TGFbeta, TGF-beta1 and TGF-beta2, in the knee joint fluid using a canine model. Twenty-four outbred dogs were divided into three groups. The control animals were given a normal diet, while the treated animals were given 300 mg ASU every three days or every day. Joint fluid samples were obtained prior to treatment, and at the end of every month (up to three months). TGF-beta1 and TGF-beta2 levels were measured using a quantitative sandwich enzyme immunoassay technique. ASU treatment caused an increase in TGF-beta1 and TGF-beta2 levels in the joint fluid when compared to controls. The different doses did not cause a significant difference in joint fluid TGF levels. TGF-beta1 levels in the treated animals reached maximum values at the end of the second month and then decreased after the third month, while TGF-beta2 levels showed a marginal increase during the first two months, followed by a marked increase at the end of the third month. In conclusion, ASU increased both TGF-beta1 and TGF-beta2 levels in knee joint fluid.

  13. Serum amyloid A isoforms in serum and synovial fluid from spontaneously diseased dogs with joint diseases or other conditions.

    PubMed

    Kjelgaard-Hansen, Mads; Christensen, Michelle B; Lee, Marcel H; Jensen, Asger L; Jacobsen, Stine

    2007-06-15

    Serum amyloid A (SAA) is a major acute phase protein in dogs. However, knowledge of qualitative properties of canine SAA and extent of its synthesis in extrahepatic tissues is limited. The aim of the study was to investigate expression of different SAA isoforms in serum and synovial fluid in samples obtained from dogs (n=16) suffering from different inflammatory or non-inflammatory conditions, which were either related or unrelated to joints. Expression of SAA isoforms was visualized by denaturing isoelectric focusing and Western blotting. Serum amyloid A was present in serum from all dogs with systemic inflammatory activity, and up to four major isoforms with apparent isoelectric points between 6.1 and 7.9 were identified. In synovial fluid from inflamed joints one or more highly alkaline SAA isoforms (with apparent isoelectric points above 9.3) were identified, with data suggesting local production of these isoforms in the canine inflamed joint.

  14. Agarose gel electrophoresis of joint fluid using Hyrys-Hydrasys SEBIA system as a new prognostic tool for periprosthetic osteolysisin revision arthroplasty

    PubMed Central

    Chiva, A

    2013-01-01

    Rationale. Prevention of wear-mediated osteolysis, the most common complication in total joint arthroplasty, is a great challenge for orthopedic surgery. Despite the diversity of current biomarkers of periprosthetic osteolysis (products of wear, bone turnover and inflammatory biomarkers), the major interferences and the great amount of sample necessary for analysis limit their use in clinical practice. Objective. The aim of this paper is to present three new electrophoretic methods using Hyrys-Hydrasys SEBIA system that have been used for the first time in Electrophoresis Laboratory of our hospital in the analysis of joint fluid for the prevention of periprosthetic osteolysis in revision arthroplasty. Methods and results. Analytical aspects of agarose gel electrophoresis of joint fluid proteins and lipoproteins as well as SDS-agarose gel electrophoresis of joint fluid proteins, their performances and clinical value are presented. The decreased level of albumin and increased level of alpha1 and alpha2 globulins were frequent changes detected on SEBIA electropherograms and good indicator for the presence of an inflammatory reaction generated by particle debris. In addition, a slightly increase of LDL mobility could provide good information about a high oxidative stress. Moreover, the Ig G assessed by using SDS-agarose gel electrophoresis could be a potential biomarker for an immunological reaction towards orthopedic implants. Discussion. Electrophoresis of joint fluid using Hyrys-Hydrasys SEBIA France system is a new analytical technique able to remove the most of current biomarkers disadvantages due to the determination of particular proteins (acute phase proteins, albumin, lipoproteins, and immunoglobulins) by using minimal amounts of joint fluid with minor interferences, minimal cost and rapid results. Abbreviations CTX, crosslinked C-telopeptide; IL- interleukins; Ig G, immunoglobulin G; LDL, low density lipoprotein; NTX, crosslinked N-telopeptide; PICP

  15. Tribological performance of the biological components of synovial fluid in artificial joint implants

    NASA Astrophysics Data System (ADS)

    Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Moradi, Ali; Masjuki, H. H.; Pingguan-Murphy, Belinda

    2015-08-01

    The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.

  16. The transport of wear particles in the prosthetic hip joint: a computational fluid dynamics investigation.

    PubMed

    Hölzer, Andreas; Schröder, Christian; Woiczinski, Matthias; Sadoghi, Patrick; Müller, Peter E; Jansson, Volkmar

    2012-02-02

    The joint fluid mechanics and transport of wear particles in the prosthetic hip joint were analyzed for subluxation and flexion motion using computational fluid dynamics (CFD). The entire joint space including a moving capsule boundary was considered. It was found that particles suspended in the joint space are drawn into the joint gap between prosthesis cup and head during subluxation, which was also documented by Lundberg et al. (2007; Journal of Biomechanics 40, 1676-1685), however, wear particles remain in the joint gap. Wear particles leave the joint gap during flexion and can finally migrate to the proximal boundaries including the acetabular bone, where the particle deposition can cause osteolysis according to the established literature. Thus, the present study supports the theory of polyethylene wear particle induced osteolysis of the acetabular bone as a major factor in the loosening of hip prosthesis cups. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Time required to achieve maximum concentration of amikacin in synovial fluid of the distal interphalangeal joint after intravenous regional limb perfusion in horses.

    PubMed

    Kilcoyne, Isabelle; Nieto, Jorge E; Knych, Heather K; Dechant, Julie E

    2018-03-01

    OBJECTIVE To determine the maximum concentration (Cmax) of amikacin and time to Cmax (Tmax) in the distal interphalangeal (DIP) joint in horses after IV regional limb perfusion (IVRLP) by use of the cephalic vein. ANIMALS 9 adult horses. PROCEDURES Horses were sedated and restrained in a standing position and then subjected to IVRLP (2 g of amikacin sulfate diluted to 60 mL with saline [0.9% NaCl] solution) by use of the cephalic vein. A pneumatic tourniquet was placed 10 cm proximal to the accessory carpal bone. Perfusate was instilled with a peristaltic pump over a 3-minute period. Synovial fluid was collected from the DIP joint 5, 10, 15, 20, 25, and 30 minutes after IVRLP; the tourniquet was removed after the 20-minute sample was collected. Blood samples were collected from the jugular vein 5, 10, 15, 19, 21, 25, and 30 minutes after IVRLP. Amikacin was quantified with a fluorescence polarization immunoassay. Median Cmax of amikacin and Tmax in the DIP joint were determined. RESULTS 2 horses were excluded because an insufficient volume of synovial fluid was collected. Median Cmax for the DIP joint was 600 μg/mL (range, 37 to 2,420 μg/mL). Median Tmax for the DIP joint was 15 minutes. CONCLUSIONS AND CLINICAL RELEVANCE Tmax of amikacin was 15 minutes after IVRLP in horses and Cmax did not increase > 15 minutes after IVRLP despite maintenance of the tourniquet. Application of a tourniquet for 15 minutes should be sufficient for completion of IVRLP when attempting to achieve an adequate concentration of amikacin in the synovial fluid of the DIP joint.

  18. Optimal probes for withdrawal of uncontaminated fluid samples

    NASA Astrophysics Data System (ADS)

    Sherwood, J. D.

    2005-08-01

    Withdrawal of fluid by a composite probe pushed against the face z =0 of a porous half-space z >0 is modeled assuming incompressible Darcy flow. The probe is circular, of radius a, with an inner sampling section of radius αa and a concentric outer guard probe αa fluid 1, and the region z >βa is saturated with fluid 2; the two fluids have the same viscosity. It is assumed that the interface between the two fluids is sharp and remains so as it moves through the rock. The pressure in the probe is lower than that of the pore fluid in the rock, so that the fluid interface is convected with the fluids towards the probe. This idealized axisymmetric problem is solved numerically, and it is shown that an analysis based on far-field spherical flow towards a point sink is a good approximation when the nondimensional depth of fluid 1 is large, i.e., β ≫1. The inner sampling probe eventually produces pure fluid 2, and this technique has been proposed for sampling pore fluids in rock surrounding an oil well [A. Hrametz, C. Gardner, M. Wais, and M. Proett, U.S. Patent No. 6,301,959 B1 (16 October 2001)]. Fluid 1 is drilling fluid filtrate, which has displaced the original pore fluid (fluid 2), a pure sample of which is required. The time required to collect an uncontaminated sample of original pore fluid can be minimized by a suitable choice of the probe geometry α [J. Sherwood, J. Fitzgerald and B. Hill, U.S. Patent No. 6,719,049 B2 (13 April 2004)]. It is shown that the optimal choice of α depends on the depth of filtrate invasion β and the volume of sample required.

  19. Direct Detection and Identification of Prosthetic Joint Infection Pathogens in Synovial Fluid by Metagenomic Shotgun Sequencing.

    PubMed

    Ivy, Morgan I; Thoendel, Matthew J; Jeraldo, Patricio R; Greenwood-Quaintance, Kerryl E; Hanssen, Arlen D; Abdel, Matthew P; Chia, Nicholas; Yao, Janet Z; Tande, Aaron J; Mandrekar, Jayawant N; Patel, Robin

    2018-05-30

    Background: Metagenomic shotgun sequencing has the potential to transform how serious infections are diagnosed by offering universal, culture-free pathogen detection. This may be especially advantageous for microbial diagnosis of prosthetic joint infection (PJI) by synovial fluid analysis, since synovial fluid cultures are not universally positive, and synovial fluid is easily obtained pre-operatively. We applied a metagenomics-based approach to synovial fluid in an attempt to detect microorganisms in 168 failed total knee arthroplasties. Results: Genus- and species-level analysis of metagenomic sequencing yielded the known pathogen in 74 (90%) and 68 (83%) of the 82 culture-positive PJIs analyzed, respectively, with testing of two (2%) and three (4%) samples, respectively, yielding additional pathogens not detected by culture. For the 25 culture-negative PJIs tested, genus- and species-level analysis yielded 19 (76%) and 21 (84%) samples with insignificant findings, respectively, and 6 (24%) and 4 (16%) with potential pathogens detected, respectively. Genus- and species-level analysis of the 60 culture-negative aseptic failure cases yielded 53 (88.3%) and 56 (93.3%) cases with insignificant findings, and 7 (11.7%) and 4 (6.7%) with potential clinically-significant organisms detected, respectively. There was one case of aseptic failure with synovial fluid culture growth; metagenomic analysis showed insignificant findings, suggesting possible synovial fluid culture contamination. Conclusion: Metagenomic shotgun sequencing can detect pathogens involved in PJI when applied to synovial fluid and may be particularly useful for culture-negative cases. Copyright © 2018 American Society for Microbiology.

  20. Serum and synovial fluid concentrations of keratan sulfate and hyaluronan in dogs with induced stifle joint osteoarthritis following cranial cruciate ligament transection.

    PubMed

    Budsberg, Steven C; Lenz, Mary Ellen; Thonar, Eugene J-M A

    2006-03-01

    To examine longitudinal changes in serum and synovial fluid concentrations of keratan sulfate (KS) and hyaluronan (HA) after cranial cruciate ligament (CCL) transection in dogs. 12 clinically normal adult mixed-breed dogs. Following CCL transection in the right stifle joint, KS and HA concentrations were determined in serum and neat (undiluted) synovial fluid prior to and 1, 2, 3, and 12 months after surgery. Postsurgical dilution of synovial fluid was corrected by use of urea as a passive marker. Synovial fluid KS and HA concentrations decreased at 1, 2, and 3 months after surgery in operated stifle joints, compared with baseline values. Synovial fluid KS concentration decreased in unoperated stifle joints at 1 month. A decrease in synovial fluid KS concentration was found in operated stifle joints, compared with unoperated stifle joints, at 2 and 3 months, and a decrease in synovial fluid HA concentrations was also found in operated stifle joints, compared with unoperated stifle joints, at 1, 2, and 3 months. Serum KS concentrations increased from baseline values at 3 months after surgery. Hyaluronan concentrations in operated stifle joints were lower than baseline values at 1, 2, and 3 months. Urea-adjusted synovial fluid concentrations revealed that dilution did not account for the decline in biomarker concentrations. The initial decrease and subsequent increase in synovial fluid concentrations of HA and KS may be caused by an acute inflammatory response to surgical intervention that negatively affects cartilage metabolism or an increase in production of immature proteoglycans.

  1. Combined measurement of synovial fluid α-Defensin and C-reactive protein levels: highly accurate for diagnosing periprosthetic joint infection.

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-09-03

    The diagnosis of periprosthetic joint infection remains a challenge. The purpose of this study was to evaluate the combined measurement of the levels of two synovial fluid biomarkers, α-defensin and C-reactive protein (CRP), for the diagnosis of periprosthetic joint infection. One hundred and forty-nine synovial fluid aspirates, including 112 from patients with an aseptic diagnosis and thirty-seven from patients with periprosthetic joint infection, met the inclusion criteria for this prospective study. Synovial fluid aspirates were tested for α-defensin and CRP levels with use of enzyme-linked immunosorbent assay (ELISA). The Musculoskeletal Infection Society (MSIS) definition of periprosthetic joint infection was utilized for the classification of cases as aseptic or infected. Comorbidities, such as inflammatory conditions, that could confound a test for periprosthetic joint infection were documented, but the patients with such comorbidities were included in the study. The combination of synovial fluid α-defensin and CRP tests demonstrated a sensitivity of 97% and a specificity of 100% for the diagnosis of periprosthetic joint infection. Synovial fluid α-defensin tests alone demonstrated a sensitivity of 97% and a specificity of 96% for the diagnosis of periprosthetic joint infection. Synovial fluid CRP tests, with a low threshold of 3 mg/L, reversed all-false positive α-defensin results without affecting the sensitivity of the test. The diagnostic characteristics of these assays were achieved in a population of patients demonstrating a 23% rate of systemic inflammatory diseases (in the series as a whole) and a 27% rate of concurrent antibiotic treatment (in the infection group). The synovial fluid levels of α-defensin in the setting of periprosthetic joint infection were unchanged during concurrent antibiotic treatment. The combined measurement of synovial fluid α-defensin and CRP levels correctly diagnosed 99% of the cases in this study as aseptic or

  2. Analysis of elements in a minimal amount of temporomandibular joint fluid on fluid-attenuated inversion recovery magnetic resonance images.

    PubMed

    Hanyuda, Hitoshi; Otonari-Yamamoto, Mika; Imoto, Kenichi; Sakamoto, Junichiro; Kodama, Sayaka; Kamio, Takashi; Sano, Tsukasa

    2013-01-01

    The aim of this study was to elucidate possible elements in minimal amounts of fluid (MF) in the temporomandibular joint by analyzing signal intensities in T2-weighted and fluid-attenuated inversion recovery (FLAIR) magnetic resonance (MR) images. Fifteen joints (15 patients) with MF were subjected to MR imaging to obtain T2-weighted and FLAIR images. Regions of interest were placed on MF, cerebrospinal fluid (CSF), and gray matter (GM), and their signal intensities were measured on both images. The signal intensity ratio (SIR) obtained by the signal intensity of GM between MF and CSF was compared in T2-weighted and FLAIR images. The average SIR of MF was lower than that of CSF on T2-weighted images, whereas it was higher on FLAIR images. The average suppression ratio of the signal intensity was lower for MF (24.1%) than for CSF (71.4%). MF may contain elements such as protein that are capable of inducing a shortened T1 relaxation time on MR images. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. A comparison of manual and electronic counting for total nucleated cell counts on synovial fluid from canine stifle joints.

    PubMed

    Atilola, M A; Lumsden, J H; Rooke, F

    1986-04-01

    Synovial fluids collected from the stifle joints of 20 physically normal adult dogs were subjected to cytological examination. A total nucleated cell count was performed on each sample using both an electronic cell counter and a hemocytometer. The mean of the total counts done with the electronic counter was significantly higher (1008 cells/microL) than that obtained manually with the hemocytometer (848 cells/microL).

  4. Raman spectroscopy of dried synovial fluid droplets as a rapid diagnostic for knee joint damage

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Raaii, Farhang; Roessler, Blake J.; Morris, Michael D.

    2008-02-01

    Human synovial fluid droplets were investigated using drop deposition in combination with Raman spectroscopy. Following informed consent, synovial fluid was obtained from forty human patients with various severities of knee pain and/or osteoarthritis at the time of knee arthroscopy or total joint replacement. Synovial fluid was aspirated from the knee joint of each patient and stored at -80°C until examination by near-infrared Raman spectroscopy. Synovial fluid aspirates from the knee joint of each patient were deposited onto a clean fused silica microscope slide and the droplet dried under ambient laboratory conditions. Each droplet was illuminated by a line-focused or a ring-focused 785 nm laser. As the droplet dries, biofluid components segregated based on solubility differences and a deposit that is spatially heterogeneous was made. Spectra taken from the droplet edges and center were dominated by protein bands and showed the presence of at least two protein moieties in the droplet. Band area and band height ratios (1410 cm -1/1450 cm -1) showed the greatest change between specimens from patients with mild/early osteoarthritis compared to those with severe/late stage osteoarthritis. The greatest differences were found in the center of the droplet, which contains more soluble protein components than the edges.

  5. Synovial fluid progenitors expressing CD90+ from normal but not osteoarthritic joints undergo chondrogenic differentiation without micro-mass culture.

    PubMed

    Krawetz, Roman J; Wu, Yiru Elizabeth; Martin, Liam; Rattner, Jerome B; Matyas, John R; Hart, David A

    2012-01-01

    Mesenchymal progenitor cells (MPCs) can differentiate into osteoblasts, adipocytes, and chondrocytes, and are in part responsible for maintaining tissue integrity. Recently, a progenitor cell population has been found within the synovial fluid that shares many similarities with bone marrow MPCs. These synovial fluid MPCs (sfMPCs) share the ability to differentiate into bone and fat, with a bias for cartilage differentiation. In this study, sfMPCs were isolated from human and canine synovial fluid collected from normal individuals and those with osteoarthritis (human: clinician-diagnosed, canine: experimental) to compare the differentiation potential of CD90+ vs. CD90- sfMPCs, and to determine if CD90 (Thy-1) is a predictive marker of synovial fluid progenitors with chondrogenic capacity in vitro. sfMPCs were derived from synovial fluid from normal and OA knee joints. These cells were induced to differentiate into chondrocytes and analyzed using quantitative PCR, immunofluorescence, and electron microscopy. The CD90+ subpopulation of sfMPCs had increased chondrogenic potential compared to the CD90- population. Furthermore, sfMPCs derived from healthy joints did not require a micro-mass step for efficient chondrogenesis. Whereas sfMPCs from OA synovial fluid retain the ability to undergo chondrogenic differentiation, they require micro-mass culture conditions. Overall, this study has demonstrated an increased chondrogenic potential within the CD90+ fraction of human and canine sfMPCs and that this population of cells derived from healthy normal joints do not require a micro-mass step for efficient chondrogenesis, while sfMPCs obtained from OA knee joints do not differentiate efficiently into chondrocytes without the micro-mass procedure. These results reveal a fundamental shift in the chondrogenic ability of cells isolated from arthritic joint fluids, and we speculate that the mechanism behind this change of cell behavior is exposure to the altered milieu of the OA

  6. Characterisation of lubricin in synovial fluid from horses with osteoarthritis.

    PubMed

    Svala, E; Jin, C; Rüetschi, U; Ekman, S; Lindahl, A; Karlsson, N G; Skiöldebrand, E

    2017-01-01

    The glycoprotein lubricin contributes to the boundary lubrication of the articular cartilage surface. The early events of osteoarthritis involve the superficial layer where lubricin is synthesised. To characterise the glycosylation profile of lubricin in synovial fluid from horses with osteoarthritis and study secretion and degradation of lubricin in an in vitro inflammation cartilage model. In vitro study. Synovial fluid samples collected from horses with joints with normal articular cartilage and structural osteoarthritic lesions; with and without osteochondral fragments, were analysed for the lubricin glycosylation profiles. Articular cartilage explants were stimulated with or without interleukin-1β for 25 days. Media samples collected at 3-day intervals were analysed by quantitative proteomics, western blot and enzyme-linked immunosorbent assay. O-glycosylation profiles in synovial fluid revealed both Core 1 and 2 O-glycans, with Core 1 O-glycans predominating. Synovial fluid from normal joints (49.5 ± 1.9%) contained significantly lower amounts of monosialylated Core 1 O-glycans compared with joints with osteoarthritis (53.8 ± 7.8%, P = 0.03) or joints with osteochondral fragments (57.3 ± 8.8%, P = 0.001). Additionally, synovial fluid from normal joints (26.7 ± 6.7%) showed higher amounts of disialylated Core 1 O-glycan than from joints with osteochondral fragments (21.2 ± 4.9%, P = 0.03). A C-terminal proteolytic cleavage site in lubricin was found in synovial fluid from normal and osteochondral fragment joints and in media from interleukin-1β stimulated and unstimulated articular cartilage explants. This is the first demonstration of a change in the glycosylation profile of lubricin in synovial fluid from diseased equine joints compared with that from normal joints. We demonstrate an identical proteolytic cleavage site of lubricin both in vitro and in vivo. The reduced sialation of lubricin in synovial fluid from diseased joints may affect the

  7. Excellent AUC for joint fluid cytology in the detection/exclusion of hip and knee prosthetic joint infection.

    PubMed

    Gallo, Jiri; Juranova, Jarmila; Svoboda, Michal; Zapletalova, Jana

    2017-09-01

    The aim of this study was to evaluate the characteristics of synovial fluid (SF) white cell count (SWCC) and neutrophil/lymphocyte percentage in the diagnosis of prosthetic joint infection (PJI) for particular threshold values. This was a prospective study of 391 patients in whom SF specimens were collected before total joint replacement revisions. SF was aspirated before joint capsule incision. The PJI diagnosis was based only on non-SF data. Receiver operating characteristic plots were constructed for the SWCC and differential counts of leukocytes in aspirated fluid. Logistic binomic regression was used to distinguish infected and non-infected cases in the combined data. PJI was diagnosed in 78 patients, and aseptic revision in 313 patients. The areas (AUC) under the curve for the SWCC, the neutrophil and lymphocyte percentages were 0.974, 0.962, and 0.951, respectively. The optimal cut-off for PJI was 3,450 cells/μL, 74.6% neutrophils, and 14.6% lymphocytes. Positive likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 19.0, 10.4, and 9.5, respectively. Negative likelihood ratios for the SWCC, neutrophil and lymphocyte percentages were 0.06, 0.076, and 0.092, respectively. Based on AUC, the present study identified cut-off values for the SWCC and differential leukocyte count for the diagnosis of PJI. The likelihood ratio for positive/negative SWCCs can significantly change the pre-test probability of PJI.

  8. Fluid sampling system

    DOEpatents

    Houck, Edward D.

    1994-01-01

    An fluid sampling system allows sampling of radioactive liquid without spillage. A feed tank is connected to a liquid transfer jet powered by a pumping chamber pressurized by compressed air. The liquid is pumped upwardly into a sampling jet of a venturi design having a lumen with an inlet, an outlet, a constricted middle portion, and a port located above the constricted middle portion. The liquid is passed under pressure through the constricted portion causing its velocity to increase and its pressure to decreased, thereby preventing liquid from escaping. A septum sealing the port can be pierced by a two pointed hollow needle leading into a sample bottle also sealed by a pierceable septum affixed to one end. The bottle is evacuated by flow through the sample jet, cyclic variation in the sampler jet pressure periodically leaves the evacuated bottle with lower pressure than that of the port, thus causing solution to pass into the bottle. The remaining solution in the system is returned to the feed tank via a holding tank.

  9. Fluid sampling system

    DOEpatents

    Houck, E.D.

    1994-10-11

    An fluid sampling system allows sampling of radioactive liquid without spillage. A feed tank is connected to a liquid transfer jet powered by a pumping chamber pressurized by compressed air. The liquid is pumped upwardly into a sampling jet of a venturi design having a lumen with an inlet, an outlet, a constricted middle portion, and a port located above the constricted middle portion. The liquid is passed under pressure through the constricted portion causing its velocity to increase and its pressure to be decreased, thereby preventing liquid from escaping. A septum sealing the port can be pierced by a two pointed hollow needle leading into a sample bottle also sealed by a pierceable septum affixed to one end. The bottle is evacuated by flow through the sample jet, cyclic variation in the sampler jet pressure periodically leaves the evacuated bottle with lower pressure than that of the port, thus causing solution to pass into the bottle. The remaining solution in the system is returned to the feed tank via a holding tank. 4 figs.

  10. Well fluid isolation and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. A seal may be positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Purged well fluid is stored in a riser above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  11. Internally supported flexible duct joint. [device for conducting fluids in high pressure systems

    NASA Technical Reports Server (NTRS)

    Kuhn, R. F., Jr. (Inventor)

    1975-01-01

    An internally supported, flexible duct joint for use in conducting fluids under relatively high pressures in systems where relatively large deflection angles must be accommodated is presented. The joint includes a flexible tubular bellows and an elongated base disposed within the bellows. The base is connected through radiating struts to the bellows near mid-portion and to each of the opposite end portions of the bellows through a pivotal connecting body. A motion-controlling linkage is provided for linking the connecting bodies, whereby angular displacement of the joint is controlled and uniformity in the instantaneous bend radius of the duct is achieved as deflection is imposed.

  12. Canine adipose-derived stromal cell viability following exposure to synovial fluid from osteoarthritic joints.

    PubMed

    Kiefer, Kristina M; O'Brien, Timothy D; Pluhar, Elizabeth G; Conzemius, Michael

    2015-01-01

    Stem cell therapy used in clinical application of osteoarthritis in veterinary medicine typically involves intra-articular injection of the cells, however the effect of an osteoarthritic environment on the fate of the cells has not been investigated. Assess the viability of adipose derived stromal cells following exposure to osteoarthritic joint fluid. Adipose derived stromal cells (ASCs) were derived from falciform adipose tissue of five adult dogs, and osteoarthritic synovial fluid (SF) was obtained from ten patients undergoing surgical intervention on orthopedic diseases with secondary osteoarthritis. Normal synovial fluid was obtained from seven adult dogs from an unrelated study. ASCs were exposed to the following treatment conditions: culture medium, normal SF, osteoarthritic SF, or serial dilutions of 1:1 to 1:10 of osteoarthritic SF with media. Cells were then harvested and assessed for viability using trypan blue dye exclusion. There was no significant difference in the viability of cells in culture medium or normal SF. Significant differences were found between cells exposed to any concentration of osteoarthritic SF and normal SF and between cells exposed to undiluted osteoarthritic SF and all serial dilutions. Subsequent dilutions reduced cytotoxicity. Osteoarthritic synovial fluid in this ex vivo experiment is cytotoxic to ASCs, when compared with normal synovial fluid. Current practice of direct injection of ASCs into osteoarthritic joints should be re-evaluated to determine if alternative means of administration may be more effective.

  13. C5a aggravates dysfunction of the articular cartilage and synovial fluid in rats with knee joint immobilization.

    PubMed

    Lu, Wei; Wang, Lin; Yao, Jing; Wo, Chunxin; Chen, Yu

    2018-06-22

    Degenerative alterations in articular cartilage are involved in the pathogenesis of osteoarthritis. The present study aimed to evaluate the role of complement component 5a (C5a) in osteoarthritic alterations in the articular cartilage and synovialis via a joint immobilization (IM) rat model. Rats were assigned to three groups: Control, IM and IM+anti‑C5a antibody (IM+anti‑C5a) groups. A terminal deoxynucleotidyl transferase dUTP nick end labeling assay and hematoxylin and eosin staining were used to evaluate the morphological alterations in the articular cartilage and synovialis. Reverse transcription‑quantitative polymerase chain reaction (RT‑qPCR) analysis, immunohistochemical analysis and western blotting were used to evaluate C5a expression in the articular cartilage and synovialis. An ELISA was used to evaluate C5a‑induced alterations in interleukin (IL)‑1β, IL‑17A and tumor necrosis factor (TNF)‑α levels in the serum and joint fluid. The results demonstrated that knee joint immobilization induced destruction of knee joint synovial fluid and cartilage in the IM and IM+anti‑C5a antibody groups. Immobilization significantly increased the expression levels of C5a in serum and joint fluid in the IM group. Immunohistochemistry, western blotting and RT‑qPCR analysis illustrated markedly increased expression of C5a in the IM group. Immobilization markedly increased the IL‑1β, IL‑17A and TNF‑α expression levels in the serum and joint fluid in the IM group. Anti‑C5a was able to decrease immobilization‑induced alterations in morphology and cytokines compared with the IM group. The expression of C5a was increased in synoviocytes and joint cartilage in the IM model. Pro‑inflammatory cytokines, including TNF‑α and IL‑1β were released in the activated synoviocytes via the induction of C5a, suggesting that C5a serves an important role in joint inflammatory processes.

  14. Synovial fluid multiplex PCR is superior to culture for detection of low-virulent pathogens causing periprosthetic joint infection.

    PubMed

    Morgenstern, Christian; Cabric, Sabrina; Perka, Carsten; Trampuz, Andrej; Renz, Nora

    2018-02-01

    Analysis of joint aspirate is the standard preoperative investigation for diagnosis of periprosthetic joint infection (PJI). We compared the diagnostic performance of culture and multiplex polymerase chain reaction (PCR) of synovial fluid for diagnosis of PJI. Patients in whom aspiration of the prosthetic hip or knee joint was performed before revision arthroplasty were prospectively included. The performance of synovial fluid culture and multiplex PCR was compared by McNemar's chi-squared test. A total of 142 patients were included, 82 with knee and 60 with hip prosthesis. PJI was diagnosed in 77 patients (54%) and aseptic failure in 65 patients (46%). The sensitivity of synovial fluid culture and PCR was 52% and 60%, respectively, showing concordant results in 116 patients (82%). In patients with PJI, PCR missed 6 high-virulent pathogens (S. aureus, streptococci, E. faecalis, E. coli) which grew in synovial fluid culture, whereas synovial fluid culture missed 12 pathogens detected by multiplex PCR, predominantly low-virulent pathogens (Cutibacterium acnes and coagulase-negative staphylococci). In patients with aseptic failure, PCR detected 6 low-virulent organisms (predominantly C. acnes). While the overall performance of synovial fluid PCR was comparable to culture, PCR was superior for detection of low-virulent bacteria such as Cutibacterium spp. and coagulase-negative staphylococci. In addition, synovial fluid culture required several days for growth, whereas multiplex PCR provided results within 5hours in an automated manner. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Extreme pressure fluid sample transfer pump

    DOEpatents

    Halverson, Justin E.; Bowman, Wilfred W.

    1990-01-01

    A transfer pump for samples of fluids at very low or very high pressures comprising a cylinder having a piston sealed with an O-ring, the piston defining forward and back chambers, an inlet and exit port and valve arrangement for the fluid to enter and leave the forward chamber, and a port and valve arrangement in the back chamber for adjusting the pressure across the piston so that the pressure differential across the piston is essentially zero and approximately equal to the pressure of the fluid so that the O-ring seals against leakage of the fluid and the piston can be easily moved, regardless of the pressure of the fluid. The piston may be actuated by a means external to the cylinder with a piston rod extending through a hole in the cylinder sealed with a bellows attached to the piston head and the interior of the back chamber.

  16. Systems and methods for separating particles and/or substances from a sample fluid

    DOEpatents

    Mariella, Jr., Raymond P.; Dougherty, George M.; Dzenitis, John M.; Miles, Robin R.; Clague, David S.

    2016-11-01

    Systems and methods for separating particles and/or toxins from a sample fluid. A method according to one embodiment comprises simultaneously passing a sample fluid and a buffer fluid through a chamber such that a fluidic interface is formed between the sample fluid and the buffer fluid as the fluids pass through the chamber, the sample fluid having particles of interest therein; applying a force to the fluids for urging the particles of interest to pass through the interface into the buffer fluid; and substantially separating the buffer fluid from the sample fluid.

  17. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  18. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  19. Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.

    PubMed

    Pawaskar, Sainath Shrikant; Ingham, Eileen; Fisher, John; Jin, Zhongmin

    2011-01-01

    The articular cartilage covering the ends of the bones of diarthrodial synovial joints is thought to have evolved so that the loads are transferred under different and complex conditions, with a very high degree of efficiency and without compromising the structural integrity of the tissue for the life of an individual. These loading conditions stem from different activities such as walking, and standing. The integrity of cartilage may however become compromised due to congenital disease, arthritis or trauma. Hemiarthroplasty is a potentially conservative treatment when only the femoral cartilage is affected as in case of femoral neck fractures. In hemiarthroplasty, a metallic femoral prosthesis is used to articulate against the natural acetabular cartilage. It has also been hypothesized that biphasic lubrication is the predominant mechanism protecting the cartilage through a very high fluid load support which lowers friction. This may be altered due to hemiarthroplasty and have a direct effect on the frictional shear stresses and potentially cartilage degradation and wear. This study modelled nine activities of daily living and investigated the contact mechanics of a hip joint with a hemiarthroplasty, focussing particularly on the role of the fluid phase. It was shown that in most of the activities studied the peak contact stresses and peak fluid pressures were in the superior dome or lateral roof of the acetabulum. Total fluid load support was very high (~90%) in most of the activities which would shield the solid phase from being subjected to very high contact stresses. This was dependent not only on the load magnitude but also the direction and hence on the location of the contact area with respect to the cartilage coverage. Lower fluid load support was found when the contact area was nearer the edges where the fluid drained easily. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Pre-operative intra-articular deep tissue sampling with novel retrograde forceps improves the diagnostics in periprosthetic joint infection.

    PubMed

    Wimmer, Matthias D; Ploeger, Milena M; Friedrich, Max J; Hügle, Thomas; Gravius, Sascha; Randau, Thomas M

    2017-07-01

    Histopathological tissue analysis is a key parameter within the diagnostic algorithm for suspected periprosthetic joint infections (PJIs), conventionally acquired in open surgery. In 2014, Hügle and co-workers introduced novel retrograde forceps for retrograde synovial biopsy with simultaneous fluid aspiration of the knee joint. We hypothesised that tissue samples acquired by retrograde synovial biopsy are equal to intra-operatively acquired deep representative tissue samples regarding bacterial detection and differentiation of periprosthetic infectious membranes. Thirty patients (male n = 15, 50%; female n = 15, 50%) with 30 suspected PJIs in painful total hip arthroplasties (THAs) were included in this prospective, controlled, non-blinded trial. The results were compared with intra-operatively obtained representative deep tissue samples. In summary, 27 out of 30 patients were diagnosed correctly as infected (17/17) or non-infected (10/13). The sensitivity to predict a PJI using the Retroforce® sampling forceps in addition to standard diagnostics was 85%, the specificity 100%. Retrograde synovial biopsy is a new and rapid diagnostic procedure under local anaesthesia in patients with painful THAs with similar histological results compared to deep tissue sampling.

  1. Cytokine mRNA expression in synovial fluid of affected and contralateral stifle joints and the left shoulder joint in dogs with unilateral disease of the stifle joint.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Duchateau, Luc; Cox, Eric

    2007-09-01

    To examine mRNA expression of cytokines in synovial fluid (SF) cells from dogs with cranial cruciate ligament (CrCL) rupture and medial patellar luxation (MPL) and determine mRNA expression for 3 joints (affected stifle, unaffected contralateral stifle, and left shoulder joints) in dogs with unilateral CrCL rupture. 29 stifle joints with CrCL rupture (29 dogs), 8 stifle joints with MPL (7 dogs), and 24 normal stifle joints (16 clinically normal dogs). Immediately before reconstructive surgery, SF was aspirated from the cruciate-deficient stifle joint or stifle joint with MPL. Fourteen of 29 dogs had unilateral CrCL rupture; SF was also aspirated from the unaffected contralateral stifle joint and left shoulder joint. Those 14 dogs were examined 6 and 12 months after reconstructive surgery. Total RNA was extracted from SF cells and reverse transcription-PCR assay was performed to obtain cDNA. Canine-specific cytokine mRNA expression was determined by use of a real-time PCR assay. Interleukin (IL)-8 and -10 and interferon-gamma expression differed significantly between dogs with arthropathies and dogs with normal stifle joints. For the 14 dogs with unilateral CrCL rupture, a significant difference was found for IL-8 expression. Before reconstructive surgery, IL-8 expression differed significantly between the affected stifle joint and left shoulder joint or contralateral stifle joint. Six months after surgery, IL-8 expression was significantly increased in the unaffected contralateral stifle joint, compared with the shoulder joint. No conclusions can be made regarding the role of the examined cytokines in initiation of CrCL disease.

  2. Products resulting from cleavage of the interglobular domain of aggrecan in samples of synovial fluid collected from dogs with early- and late-stage osteoarthritis.

    PubMed

    Innes, John F; Little, Chris B; Hughes, Clare E; Caterson, Bruce

    2005-10-01

    To investigate interglobular domain (IGD) cleavage of aggrecan in dogs with naturally developing osteoarthritis (OA). Samples of synovial fluid (SF) obtained from 3 cubital (elbow) joints and 3 stifle joints of 4 clinically normal dogs, 24 elbow joints of 12 dogs with early-stage OA, 8 stifle joints of 5 dogs with early-stage OA, and 10 stifle joints of 9 dogs with late-stage OA. Fractions of SF were assayed for total glycosaminoglycan (GAG) content and also subjected to Western blot analysis by use of monoclonal antibodies against neoepitopes generated by cleavage of the IGD of the aggrecan protein core by matrix metalloproteinase (MMP; BC-14) and aggrecanase (BC-3). Total GAG content of SF from joints of clinically normal dogs did not differ from that of dogs with early-stage OA. The GAG content of SF from joints of dogs with late-stage OA was significantly lower, compared with GAG content for other SF samples. Aggrecanase-generated fragments were detected in SF from all groups but not in all samples. Matrix metalloproteinase-generated fragments were not detected in any SF samples. In early-stage OA, high-molecular-weight aggrecanase-generated aggrecan catabolites were evident. GAG content of SF obtained from dogs with late-stage OA is significantly decreased, suggesting proteoglycan depletion of cartilage. Aggrecanases, but not MMPs, are the major proteolytic enzymes responsible for IGD cleavage of aggrecan in canine joints. Analyses of SF samples to detect aggrecanase-generated catabolites may provide an early biomarker for discriminating early- and late-stage OA in dogs.

  3. Crack Damage Parameters and Dilatancy of Artificially Jointed Granite Samples Under Triaxial Compression

    NASA Astrophysics Data System (ADS)

    Walton, G.; Alejano, L. R.; Arzua, J.; Markley, T.

    2018-06-01

    A database of post-peak triaxial test results was created for artificially jointed planes introduced in cylindrical compression samples of a Blanco Mera granite. Aside from examining the artificial jointing effect on major rock and rock mass parameters such as stiffness, peak strength and residual strength, other strength parameters related to brittle cracking and post-yield dilatancy were analyzed. Crack initiation and crack damage values for both the intact and artificially jointed samples were determined, and these damage envelopes were found to be notably impacted by the presence of jointing. The data suggest that with increased density of jointing, the samples transition from a combined matrix damage and joint slip yielding mechanism to yield dominated by joint slip. Additionally, post-yield dilation data were analyzed in the context of a mobilized dilation angle model, and the peak dilation angle was found to decrease significantly when there were joints in the samples. These dilatancy results are consistent with hypotheses in the literature on rock mass dilatancy.

  4. Clinical value of jointly detection serum lactate dehydrogenase/pleural fluid adenosine deaminase and pleural fluid carcinoembryonic antigen in the identification of malignant pleural effusion.

    PubMed

    Zhang, Fan; Hu, Lijuan; Wang, Junjun; Chen, Jian; Chen, Jie; Wang, Yumin

    2017-09-01

    Limited data are available for the diagnostic value, and for the diagnostic sensitivity and specificity of joint detection of serum lactate dehydrogenase (sLDH)/pleural fluid adenosine deaminase (pADA) and pleural fluid carcinoembryonic antigen (pCEA) in malignant pleural effusion (MPE). We collected 987 pleural effusion specimens (of which 318 were malignant pleural effusion, 374 were tubercular pleural effusion, and 295 were parapneumonic effusion specimens) from the First Affiliated Hospital of Wenzhou Medical University from July 2012 to March 2016. The pADA, sLDH, pleural fluid LDH (pLDH), serum C-reactive protein (sCRP), pleural fluid protein, pCEA, white blood cell (WBC), and red blood cell (RBC) were analyzed, and the clinical data of each group were collected for statistical analysis. The level of sLDH/pADA, pCEA, and RBC from the MPE group was markedly higher than the tuberculosis pleural effusion (TB) group (Mann-Whitney U=28422.000, 9278.000, 30518, P=.000, .000, .000) and the parapneumonic pleural fluid group (Mann-Whitney U=5972.500, 7113.000, 36750.500, P=.000, .000, .000). The receiver operating characteristic curve ROC showed that the area under the ROC curve (AUC) (=0.924, 0.841) of pCEA and sLDH/pADA (cutoff=4.9, 10.6) were significantly higher than other markers for the diagnosis of MPE. Thus, joint detection of pCEA and sLDH/pADA suggested that the sensitivity, specificity, and AUC was 0.94, 81.70, and 94.32 at the cutoff 0.16 and diagnostic performance was higher than pCEA or sLDH/pADA. Joint detection of sLDH/pADA and pCEA can be used as a good indicator for the identification of benign and MPE with higher sensitivity and specificity than pCEA or sLDH/pADA. © 2016 Wiley Periodicals, Inc.

  5. Synovial fluid matrix metalloproteinase-2 and -9 activities in dogs suffering from joint disorders.

    PubMed

    Murakami, Kohei; Maeda, Shingo; Yonezawa, Tomohiro; Matsuki, Naoaki

    2016-07-01

    The activity of matrix metalloproteinase (MMP)-2 and MMP-9 in synovial fluids (SF) sampled from dogs with joint disorders was investigated by gelatin zymography and densitometry. Pro-MMP-2 showed similar activity levels in dogs with idiopathic polyarthritis (IPA; n=17) or canine rheumatoid arthritis (cRA; n=4), and healthy controls (n=10). However, dogs with cranial cruciate ligament rupture (CCLR; n=5) presented significantly higher pro-MMP-2 activity than IPA and healthy dogs. Meanwhile, dogs with IPA exhibited significantly higher activity of pro- and active MMP-9 than other groups. Activity levels in pro- and active MMP-9 in cRA and CCLR dogs were not significantly different from those in healthy controls. Different patterns of MMP-2 and MMP-9 activity may reflect the differences in the underlying pathological processes.

  6. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    PubMed

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  7. Synovial fluid matrix metalloproteinase-2 and -9 activities in dogs suffering from joint disorders

    PubMed Central

    MURAKAMI, Kohei; MAEDA, Shingo; YONEZAWA, Tomohiro; MATSUKI, Naoaki

    2016-01-01

    The activity of matrix metalloproteinase (MMP)-2 and MMP-9 in synovial fluids (SF) sampled from dogs with joint disorders was investigated by gelatin zymography and densitometry. Pro-MMP-2 showed similar activity levels in dogs with idiopathic polyarthritis (IPA; n=17) or canine rheumatoid arthritis (cRA; n=4), and healthy controls (n=10). However, dogs with cranial cruciate ligament rupture (CCLR; n=5) presented significantly higher pro-MMP-2 activity than IPA and healthy dogs. Meanwhile, dogs with IPA exhibited significantly higher activity of pro- and active MMP-9 than other groups. Activity levels in pro- and active MMP-9 in cRA and CCLR dogs were not significantly different from those in healthy controls. Different patterns of MMP-2 and MMP-9 activity may reflect the differences in the underlying pathological processes. PMID:26902805

  8. Sulforaphane Modulates Joint Inflammation in a Murine Model of Complete Freund's Adjuvant-Induced Mono-Arthritis.

    PubMed

    Silva Rodrigues, João Francisco; Silva E Silva, Cristiane; França Muniz, Thayanne; de Aquino, Alana Fernanda; Neuza da Silva Nina, Larissa; Fialho Sousa, Nagila Caroline; Nascimento da Silva, Luis Claudio; de Souza, Breno Glaessner Gomes Fernandes; da Penha, Tatiana Aranha; Abreu-Silva, Ana Lúcia; de Sá, Joicy Cortez; Soares Fernandes, Elizabeth; Grisotto, Marcos Augusto Grigolin

    2018-04-24

    Rheumatoid arthritis (RA) is characterized by inflammation of one or more joints, and affects ~1% of the adult population worldwide. Sulforaphane (SFN) is a natural compound that has been suggested as an antioxidant. Here, SFN’s effects were evaluated in a murine mono-arthritis model. Mono-arthritis was induced in mice by a single intra-articular injection of Complete Freund’s Adjuvant (CFA-10 µg/joint, in 10 µL) into the ipsilateral joint. The contralateral joint received an equal volume of PBS. On the 4th day post-joint inflammation induction, animals received either SFN (10 mg/kg) or vehicle (3% DMSO in saline), intraperitoneally (i.p.), twice a day for 3 days. Joint swelling and secondary mechanical allodynia and hyperalgesia were evaluated over 7 days post-CFA. After this period, animals were culled and their blood and synovial fluid samples were collected for analysis of cell populations, cytokine release and thioredoxin reductase (TrxR) activity. Knee joint samples were also collected for histology. SFN reduced joint swelling and damage whilst increasing the recruitment of Ly6C⁺ and Ly6G⁺ cells to CFA-injected joints. SFN-treated animals presented down-regulation of CD11b and CD62L on synovial fluid Ly6G⁺ cells. Synovial fluid samples obtained from CFA-injected joints and plasma samples of SFN-treated mice presented higher levels of IL-6 and increased activity of TrxR, in comparison with controls. These results indicate that SFN reduces knee joint damage by modulating cell activation/migration to the joints, cytokine production and increasing the activity of TrxR, and therefore, may represent an alternative treatment to joint inflammation.

  9. Performance of automated multiplex PCR using sonication fluid for diagnosis of periprosthetic joint infection: a prospective cohort.

    PubMed

    Renz, Nora; Feihl, Susanne; Cabric, Sabrina; Trampuz, Andrej

    2017-12-01

    Sonication of explanted prostheses improved the microbiological diagnosis of periprosthetic joint infections (PJI). We evaluated the performance of automated multiplex polymerase chain reaction (PCR) using sonication fluid for the microbiological diagnosis of PJI. In a prospective cohort using uniform definition criteria for PJI, explanted joint prostheses were investigated by sonication and the resulting sonication fluid was analyzed by culture and multiplex PCR. McNemar's Chi-squared test was used to compare the performance of diagnostic tests. Among 111 patients, PJI was diagnosed in 78 (70%) and aseptic failure in 33 (30%). For the diagnosis of PJI, the sensitivity and specificity of periprosthetic tissue culture was 51 and 100%, of sonication fluid culture 58 and 100%, and of sonication fluid PCR 51 and 94%, respectively. Among 70 microorganisms, periprosthetic tissue culture grew 52 (74%), sonication fluid culture grew 50 (71%) and sonication fluid PCR detected 37 pathogens (53%). If only organisms are considered, for which primers are included in the test panel, PCR detected 37 of 58 pathogens (64%). The sonication fluid PCR missed 19 pathogens (predominantly oral streptococci and anaerobes), whereas 7 additional microorganisms were detected only by PCR (including Cutibacterium spp. and coagulase-negative staphylococci). The performance of multiplex PCR using sonication fluid is comparable to culture of periprosthetic tissue or sonication fluid. The advantages of PCR are short processing time (< 5 h) and fully automated procedure. However, culture technique is still needed due to the low sensitivity and the need of comprehensive susceptibility testing. Modification of primers or inclusion of additional ones may improve the performance of PCR, especially of low-virulent organisms.

  10. Magnetic particle translation as a surrogate measure for synovial fluid mechanics.

    PubMed

    Shah, Yash Y; Maldonado-Camargo, Lorena; Patel, Neal S; Biedrzycki, Adam H; Yarmola, Elena G; Dobson, Jon; Rinaldi, Carlos; Allen, Kyle D

    2017-07-26

    The mechanics of synovial fluid vary with disease progression, but are difficult to quantify quickly in a clinical setting due to small sample volumes. In this study, a novel technique to measure synovial fluid mechanics using magnetic nanoparticles is introduced. Briefly, microspheres embedded with superparamagnetic iron oxide nanoparticles, termed magnetic particles, are distributed through a 100μL synovial fluid sample. Then, a permanent magnet inside a protective sheath is inserted into the synovial fluid sample. Magnetic particles translate toward the permanent magnet and the percentage of magnetic particles collected by the magnet in a given time can be related to synovial fluid viscosity. To validate this relationship, magnetic particle translation was demonstrated in three phases. First, magnetic particle translation was assessed in glycerol solutions with known viscosities, demonstrating that as fluid viscosity increased, magnetic particle translation decreased. Next, the relationship between magnetic particle translation and synovial fluid viscosity was assessed using bovine synovial fluid that was progressively degenerated via ultrasonication. Here, particle collection in a given amount of time increased as fluid degenerated, demonstrating that the relationship between particle collection and fluid mechanics holds in non-Newtonian synovial fluid. Finally, magnetic particle translation was used to assess differences between healthy and OA affected joints in equine synovial fluid. Here, particle collection in a given time was higher in OA joints relative to healthy horses (p<0.001). Combined, these data demonstrate potential viability of magnetic particle translation in a clinical setting to evaluate synovial fluid mechanics in limited volumes of synovial fluid sample. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Prevalence and relevance of antibodies to type-I and -II collagen in synovial fluid of dogs with cranial cruciate ligament damage.

    PubMed

    de Rooster, H; Cox, E; van Bree, H

    2000-11-01

    To measure and compare synovial fluid antibody titers to type-I and -II collagen in stifle joints with instability caused by complete or partial cranial cruciate ligament (CCL) rupture and joints with osteoarthrosis secondary to other pathologic changes in dogs. 82 dogs with diseased stifle joints. Synovial fluid samples were collected from 7 dogs with clinically normal stifles (control group) and 82 dogs with diseased joints (50 stifle joints with complete rupture of the CCL, 20 with partial damage of the CCL, and 12 joints with radiographic signs of osteoarthritis secondary to other arthropathies). Synovial fluid samples were tested for autoantibodies to type-I and -II collagen by an ELISA. In dogs with complete and partial CCL rupture, synovial fluid antibody titers to type-I and -II collagen were significantly increased, compared with control dogs. Forty-eight percent (24/50) of samples from dogs with complete CCL rupture and 35% (7/20) of samples from dogs with partial CCL rupture had antibody titers to type-I collagen that were greater than the mean plus 2 standard deviations of the control group titers. Synovial fluid antibody titers to type-II collagen were high in 40% of the dogs with partial or (8/20) complete (20/50) CCL rupture. Dogs with osteoarthrosis secondary to other pathologic changes had significantly increased synovial fluid antibodies to type-I and -II collagen, compared with control dogs. Increases in autoantibodies to collagen in synovial fluid are not specific for the type of joint disorder. It is unlikely that the anticollagen antibodies play an active role in the initiation of weakening of the CCL.

  12. Influenza A Virus Surveillance Based on Pre-Weaning Piglet Oral Fluid Samples.

    PubMed

    Panyasing, Y; Goodell, C; Kittawornrat, A; Wang, C; Levis, I; Desfresne, L; Rauh, R; Gauger, P C; Zhang, J; Lin, X; Azeem, S; Ghorbani-Nezami, S; Yoon, K-J; Zimmerman, J

    2016-10-01

    Influenza A virus (IAV) surveillance using pre-weaning oral fluid samples from litters of piglets was evaluated in four ˜12 500 sow and IAV-vaccinated, breeding herds. Oral fluid samples were collected from 600 litters and serum samples from their dams at weaning. Litter oral fluid samples were tested for IAV by virus isolation, quantitative reverse transcription-polymerase chain reaction (qRT-PCR), RT-PCR subtyping and sequencing. Commercial nucleoprotein (NP) enzyme-linked immunosorbent assay (ELISA) kits and NP isotype-specific assays (IgM, IgA and IgG) were used to characterize NP antibody in litter oral fluid and sow serum. All litter oral fluid specimens (n = 600) were negative by virus isolation. Twenty-five oral fluid samples (25/600 = 4.2%) were qRT-PCR positive based on screening (Laboratory 1) and confirmatory testing (Laboratory 2). No hemagglutinin (HA) and neuraminidase (NA) gene sequences were obtained, but matrix (M) gene sequences were obtained for all qRT-PCR-positive samples submitted for sequencing (n = 18). Genetic analysis revealed that all M genes sequences were identical (GenBank accession no. KF487544) and belonged to the triple reassortant influenza A virus M gene (TRIG M) previously identified in swine. The proportion of IgM- and IgA-positive samples was significantly higher in sow serum and litter oral fluid samples, respectively (P < 0.01). Consistent with the extensive use of IAV vaccine, no difference was detected in the proportion of IgG- and blocking ELISA-positive sow serum and litter oral fluids. This study supported the use of oral fluid sampling as a means of conducting IAV surveillance in pig populations and demonstrated the inapparent circulation of IAV in piglets. Future work on IAV oral fluid diagnostics should focus on improved procedures for virus isolation, subtyping and sequencing of HA and NA genes. The role of antibody in IAV surveillance remains to be elucidated, but longitudinal assessment of specific

  13. Detection of calcium phosphate crystals in the joint fluid of patients with osteoarthritis – analytical approaches and challenges

    PubMed Central

    Yavorskyy, Alexander; Hernandez-Santana, Aaron; McCarthy, Geraldine

    2008-01-01

    Clinically, osteoarthritis (OA) is characterised by joint pain, stiffness after immobility, limitation of movement and, in many cases, the presence of basic calcium phosphate (BCP) crystals in the joint fluid. The detection of BCP crystals in the synovial fluid of patients with OA is fraught with challenges due to the submicroscopic size of BCP, the complex nature of the matrix in which they are found and the fact that other crystals can co-exist with them in cases of mixed pathology. Routine analysis of joint crystals still relies almost exclusively on the use of optical microscopy, which has limited applicability for BCP crystal identification due to limited resolution and the inherent subjectivity of the technique. The purpose of this Critical Review is to present an overview of some of the main analytical tools employed in the detection of BCP to date and the potential of emerging technologies such as atomic force microscopy (AFM) and Raman microspectroscopy for this purpose. PMID:18299743

  14. Elevation of a collagenase generated type II collagen neoepitope and proteoglycan epitopes in synovial fluid following induction of joint instability in the dog

    PubMed Central

    Chu, Q.; Lopez, M.; Hayashi, K.; lonescu, M.; Billinghurst, R. C.; Johnson, K. A.; Poole, A. R.; Markel, M. D.

    2007-01-01

    Summary Clinical relevance Measurement of markers of cartilage pathology in synovial fluid may provide clinical rheumatologists and osteoarthritis (OA) researchers important information for early diagnosis of OA as well as a method for monitoring disease progression and response to treatment. This study demonstrates the value of this approach in an established model of OA (cranial cruciate ligament rupture) at a point distant enough from the original surgical manipulation so as to have little to no effect on the marker concentrations. Objective The objective of this study was to determine whether measurement of markers of cartilage collagen cleavage and proteoglycan turnover in synovial fluid from a canine model could be used to detect cartilage changes following the onset of joint instability during the development of OA. Design A model of joint instability that develops OA was created in 18 mature dogs using monopolar radiofrequency energy (MRFE). MRFE was arthroscopically applied to one cranial cruciate ligament (CCL) while the contralateral CCL was sham treated. The treated CCLs ruptured approximately 8 weeks (55 ± 1.6 days) after MRFE treatment. Synovial fluid was collected at time zero prior to MRFE treatment, 4 weeks after MRFE treatment, and at 4, 8, and 16 weeks after CCL rupture. Synovial fluid concentrations of the neoepitope COL2-3/4C long (type II collagen cleavage by collagenase) and epitopes 3B3(–) (proteoglycan aggrecan sulfation) and 846 (associated with aggrecan synthesis) were analyzed. Results Compared to sham treated joints, the synovial fluid concentrations of COL2-3/4C long and 3B3(–) were significantly increased 2.2 fold and 2.9 fold, respectively, in joints with MRFE treated CCLs following CCL rupture. Concentrations of the 846 epitope in synovial fluid showed a trend toward an increase, which was not significant, after CCL rupture. Conclusions Concentrations of the collagenase-cleaved type II collagen neoepitope and 3B3(–) epitope

  15. Elevation of a collagenase generated type II collagen neoepitope and proteoglycan epitopes in synovial fluid following induction of joint instability in the dog.

    PubMed

    Chu, Q; Lopez, M; Hayashi, K; Ionescu, M; Billinghurst, R C; Johnson, K A; Poole, A R; Markel, M D

    2002-08-01

    Measurement of markers of cartilage pathology in synovial fluid may provide clinical rheumatologists and osteoarthritis (OA) researchers important information for early diagnosis of OA as well as a method for monitoring disease progression and response to treatment. This study demonstrates the value of this approach in an established model of OA (cranial cruciate ligament rupture) at a point distant enough from the original surgical manipulation so as to have little to no effect on the marker concentrations. The objective of this study was to determine whether measurement of markers of cartilage collagen cleavage and proteoglycan turnover in synovial fluid from a canine model could be used to detect cartilage changes following the onset of joint instability during the development of OA. A model of joint instability that develops OA was created in 18 mature dogs using monopolar radiofrequency energy (MRFE). MRFE was arthroscopically applied to one cranial cruciate ligament (CCL) while the contralateral CCL was sham treated. The treated CCLs ruptured approximately 8 weeks (55 +/- 1.6 days) after MRFE treatment. Synovial fluid was collected at time zero prior to MRFE treatment, 4 weeks after MRFE treatment, and at 4, 8, and 16 weeks after CCL rupture. Synovial fluid concentrations of the neoepitope COL2-3/4C long (type II collagen cleavage by collagenase) and epitopes 3B3(-) (proteoglycan aggrecan sulfation) and 846 (associated with aggrecan synthesis) were analyzed. Compared to sham treated joints, the synovial fluid concentrations of COL2-3/4C long and 3B3(-) were significantly increased 2.2 fold and 2.9 fold, respectively, in joints with MRFE treated CCLs following CCL rupture. Concentrations of the 846 epitope in synovial fluid showed a trend toward an increase, which was not significant, after CCL rupture. Concentrations of the collagenase-cleaved type II collagen neoepitope and 3B3(-) epitope in synovial fluid were significantly increased by 4 weeks and remained

  16. Potential of fluid-attenuated inversion recovery (FLAIR) in identification of temporomandibular joint effusion compared with T2-weighted images.

    PubMed

    Imoto, Kenichi; Otonari-Yamamoto, Mika; Nishikawa, Keiichi; Sano, Tsukasa; Yamamoto, Aya

    2011-08-01

    The purpose of this study was to determine the potential of fluid-attenuated inversion recovery (FLAIR) sequence images in the identification of joint effusion (JE) compared with T2-weighted images. A total of 31 joints (28 patients) with JE were investigated by magnetic resonance imaging (MRI). Regions of interest were placed over JE, cerebrospinal fluid (CSF), and gray matter (GM) on T2-weighted and FLAIR images and their signal intensities compared. The signal intensity ratios (SIRs) of JE and CSF were calculated with GM as the reference point. The Pearson product-moment correlation coefficient was used for the statistical analysis. The SIR of JE showed a strong correlation between T2-weighted and FLAIR images. However, no correlation was observed for CSF. The average suppression ratio for JE was lower than that for CSF. MRI using FLAIR sequences revealed that JE was not just water content, but a fluid accumulation containing elements such as protein. Further studies are needed, and FLAIR sequences could be useful for the diagnosis of pain and symptoms of the temporomandibular joint (TMJ). Copyright © 2011 Mosby, Inc. All rights reserved.

  17. [Correlation study between interleukin-17 and ESR and CRP in serum and the synovial fluid of rheumatoid arthritis patients of accumulated dampness-heat obstruction in joints syndrome].

    PubMed

    Liu, De-Fang; Yan, Jiao; Guo, Ming-Yang; Wang, Chao; Hu, Yong-He; Yang, Min; Yun, Ming-Dong; Luo, Yong; Zhang, Jun; Li, Hua

    2014-03-01

    To probe the function of interleukin-17 (IL-17) in rheumatoid arthritis (RA) patients of accumulated dampness-heat obstruction in joints syndrome (ADOJS) by detecting levels of IL-17 in serum and the synovial fluid and analyzing its correlation with erythrocyte sedimentation rate (ESR) and C reactive protein (CRP). From January 2011 to January 2013, recruited were 90 RA inpatients of ADOJS at Department of Integrative Medical Rheumatism, General Hospital of Chengdu Military Region, of which 28 patients had knee joint effusion. Besides, 30 healthy volunteers who received physical examination at our hospital were recruited as the normal control group, and 30 patients with osteoarthritis (OA) who had knee joint effusion were recruited as the synovial fluid control group. The expression levels of IL-17 in serum and the synovial fluid were detected by enzyme linked immunosorbent assay (ELISA), and contents of ESR and CRP were detected in RA patients. Then correlation analyses were performed between levels of IL-17 and contents of ESR and CRP. Compared with the normal serum control group, the expression levels of IL-17 in serum of RA patients significantly increased (P < 0.05). Compared with the serum of RA patients and the synovial fluid of OA patients, the expression levels of IL-17 in the synovial fluid of RA patients significantly increased (P < 0.05). The expression levels of IL-17 in serum of RA patients were not correlated with ESR or CRP (r = 0.092, -0.082; P > 0.05), and the expressional levels of IL-17 in the synovial fluid of RA patients were not correlated with ESR or CRP (r = 0.113, -0.034; P > 0.05). IL-17 was the main effector cytokine of Th17 cells. The expressional levels of IL-17 significantly increased in serum and the synovial fluid of RA patients of ADOJS, but with no correlation to ESR or CRP. It indicated that IL-17 participated in the occurrence and development of RA. Concrete mechanisms needed to be further proved in larger samples.

  18. Sampling guidelines for oral fluid-based surveys of group-housed animals.

    PubMed

    Rotolo, Marisa L; Sun, Yaxuan; Wang, Chong; Giménez-Lirola, Luis; Baum, David H; Gauger, Phillip C; Harmon, Karen M; Hoogland, Marlin; Main, Rodger; Zimmerman, Jeffrey J

    2017-09-01

    Formulas and software for calculating sample size for surveys based on individual animal samples are readily available. However, sample size formulas are not available for oral fluids and other aggregate samples that are increasingly used in production settings. Therefore, the objective of this study was to develop sampling guidelines for oral fluid-based porcine reproductive and respiratory syndrome virus (PRRSV) surveys in commercial swine farms. Oral fluid samples were collected in 9 weekly samplings from all pens in 3 barns on one production site beginning shortly after placement of weaned pigs. Samples (n=972) were tested by real-time reverse-transcription PCR (RT-rtPCR) and the binary results analyzed using a piecewise exponential survival model for interval-censored, time-to-event data with misclassification. Thereafter, simulation studies were used to study the barn-level probability of PRRSV detection as a function of sample size, sample allocation (simple random sampling vs fixed spatial sampling), assay diagnostic sensitivity and specificity, and pen-level prevalence. These studies provided estimates of the probability of detection by sample size and within-barn prevalence. Detection using fixed spatial sampling was as good as, or better than, simple random sampling. Sampling multiple barns on a site increased the probability of detection with the number of barns sampled. These results are relevant to PRRSV control or elimination projects at the herd, regional, or national levels, but the results are also broadly applicable to contagious pathogens of swine for which oral fluid tests of equivalent performance are available. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  19. [Synovial fluid from aseptically failed total hip or knee arthroplasty is not toxic to osteoblasts].

    PubMed

    Gallo, J; Zdařilová, A; Rajnochová Svobodová, A; Ulrichová, J; Radová, L; Smižanský, M

    2010-10-01

    A failure of total hip or knee artroplasty is associated with an increased production of joint fluid. This contains wear particles and host cells and proteins, and is assumed to be involved in the pathogenesis of aseptic loosening and periprosthetic osteolysis. This study investigated the effect of synovial fluid from patients with aseptically failed joint prostheses on osteoblast cultures. Synovial fluid samples were obtained from patients with failed total joint prostheses (TJP; n=36) and from control patient groups (n = 16) involving cases without TJP and osteoarthritis, without TJP but with osteoarthritis, and with stable TJP. The samples were treated in the standard manner and then cultured with the SaOS-2 cell line which shows the characteristics and behaviour of osteoblasts. Each fluid sample was also examined for the content of proteins, cells and selected cytokines (IL-1ß, TNF-α, IL-6, RANKL and OPG detected by ELISA). We tested the hypothesis assuming that the fluids from failed joints would show higher cytotoxicity to osteoblast culture and we also expected higher levels of IL-1ß, TNF-α, IL-6, and RANKL in patients with TJP failure and/ or with more severe bone loss. The statistical methods used included the Kruskal-Wallis ANOVA and Mann-Whitney U test. The fluids from failed TJPs showed the highest RANKL and the lowest OPG levels resulting in the highest RANKL/OPG ratio. However, there was no evidence suggesting that the joint fluids from failed TJPs would be more toxic to osteoblast culture than the fluids from control groups. In addition, no correlation was found between the fluid levels of molecules promoting inflammation and osteoclastic activity and the extent of bone loss in the hip (in terms of Saleh's classification) or the knee (AORI classification). In fact, the fluids from failed TJPs had higher protein levels in comparison with the controls, but the difference was not significant. The finding of high RANKL levels and low OPG

  20. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  1. Wavelet analysis of polarization maps of polycrystalline biological fluids networks

    NASA Astrophysics Data System (ADS)

    Ushenko, Y. A.

    2011-12-01

    The optical model of human joints synovial fluid is proposed. The statistic (statistic moments), correlation (autocorrelation function) and self-similar (Log-Log dependencies of power spectrum) structure of polarization two-dimensional distributions (polarization maps) of synovial fluid has been analyzed. It has been shown that differentiation of polarization maps of joint synovial fluid with different physiological state samples is expected of scale-discriminative analysis. To mark out of small-scale domain structure of synovial fluid polarization maps, the wavelet analysis has been used. The set of parameters, which characterize statistic, correlation and self-similar structure of wavelet coefficients' distributions of different scales of polarization domains for diagnostics and differentiation of polycrystalline network transformation connected with the pathological processes, has been determined.

  2. Cellular Pressure-Actuated Joint

    NASA Technical Reports Server (NTRS)

    McGuire, John R.

    2003-01-01

    A modification of a pressure-actuated joint has been proposed to improve its pressure actuation in such a manner as to reduce the potential for leakage of the pressurizing fluid. The specific joint for which the modification is proposed is a field joint in a reusable solid-fuel rocket motor (RSRM), in which the pressurizing fluid is a mixture of hot combustion gases. The proposed modification could also be applicable to other pressure-actuated joints of similar configuration.

  3. Development of a Lubricant Therapy to Prevent Development of Osteoarthritis after Acute Injury of Synovial Joints

    DTIC Science & Technology

    2016-10-01

    test whether the pathological accumulation of a specific substance found in joint fluid following an injury mediated altered synovial fluid...joint injury contributes to the development of post-traumatic OA and is due, in part, to the pathological accumulation of a...studies, SF samples will be analyzed for the suspected pathological substance as well as lubrication function. 3.b.ii. Aim 2b

  4. Technical note: A device for obtaining time-integrated samples of ruminal fluid

    USGS Publications Warehouse

    Corley, R. N.; Murphy, M.R.; Lucena, J.; Panno, S.V.

    1999-01-01

    A device was adapted to allow for time-integrated sampling of fluid from the rumen via a cannula. The sampler consisted of a cup-shaped ceramic filter positioned in the ventral rumen of a cannulated cow and attached to a tube through which fluid entering the filter was removed continuously using a peristaltic pump. Rate of ruminal fluid removal using the device was monitored over two 36-h periods (at 6-h intervals) and was not affected (P > .05) by time, indicating that the system was not susceptible to clogging during this period. Two cows having ad libitum access to a totally mixed ration were used in a split-block design to evaluate the utility of the system for obtaining time-integrated samples of ruminal fluid. Ruminal fluid VFA concentration and pattern in samples collected in two replicated 8-h periods by the time-integrated sampler (at 1-h intervals) were compared with composite samples collected using a conventional suction-strainer device (at 30-min intervals). Each 8-h collection period started 2 h before or 6 h after feeding. Results indicated that total VFA concentration was not affected (P > .05) by the sampling method. Volatile fatty acid patterns were likewise unaffected (P > .05) except that acetate was 2.5% higher (P < .05) in samples collected 2 h before feeding and valerate was 5% higher (P < .05) in samples collected 6 h after feeding by the suction-strainer device. Although significant, these differences were not considered physiologically important. We concluded that use of the ceramic filter improved the sampling of ruminal fluid by simplifying the technique and allowing time-integrated samples to be obtained.

  5. Population pharmacokinetic analysis of blood and joint synovial fluid concentrations of robenacoxib from healthy dogs and dogs with osteoarthritis.

    PubMed

    Silber, Hanna E; Burgener, Claudia; Letellier, Ingrid M; Peyrou, Mathieu; Jung, Martin; King, Jonathan N; Gruet, Philippe; Giraudel, Jerome M

    2010-12-01

    The purpose of this population analysis was to characterize the pharmacokinetic properties of robenacoxib in blood and stifle joint synovial fluid of dogs. Data were obtained from two studies: 1) 8 healthy Beagle dogs in which an acute inflammation was induced by injection of urate crystals into one joint; 2) 95 dogs from various breeds diagnosed with osteoarthritis (OA). Robenacoxib concentrations in blood and synovial fluid were measured using a validated HPLC-UV and LC-MS method. Non-linear mixed effects modeling was performed using NONMEM6. A two-compartment pharmacokinetic model with linear elimination was developed to describe blood concentrations of robenacoxib. Blood clearance in healthy animals was found to be 75% higher than in OA dogs. Synovial fluid concentrations were modeled using an effect-compartment-type model predicting longer residence times in OA dogs compared to healthy Beagles (e.g. concentrations above the IC(50) for COX-2, respectively, 16 h vs. 10 h at 1.5 mg/kg). Robenacoxib was found to reside longer at the effect site (inflamed joint) compared to blood in both healthy and OA dogs. These results may explain the good efficacy observed with once-daily dosing in clinical trials and the high safety index of robenacoxib in dogs.

  6. Effect of repeated arthrocentesis on cytologic analysis of synovial fluid in dogs.

    PubMed

    Berg, R I M; Sykes, J E; Kass, P H; Vernau, W

    2009-01-01

    Serial arthrocentesis and synovial fluid examination can be used to monitor treatment efficacy in immune-mediated polyarthritis (IMPA), but whether this procedure induces inflammation that interferes with test result interpretation is unknown. The aim of this study was to determine the effect of repeated arthrocentesis on synovial fluid cytology in healthy dogs. Nine healthy client-owned dogs. Prospective study. Arthrocentesis was performed under sedation on 4 joints (both carpi, 1 tarsus, 1 stifle) on each dog every 3 weeks, a total of 4 times. Automated cell counts were done on stifle fluid, smears were made, and differential cell counts done on smears from all joints. Slides were evaluated microscopically for erythrocyte numbers, total nucleated cell count, differential cell count, and cell morphology. Data were analyzed by 2-way analysis of variance. A total of 144 synovial fluid samples were examined. Repeated arthrocentesis was not associated with increases in synovial fluid neutrophil numbers. Mild mononuclear inflammation was detected in 13 samples from 6 dogs. Serial arthrocentesis at 3-week intervals can rarely be associated with mild mononuclear joint inflammation, but does not appear to induce neutrophilic inflammation, at least in healthy dogs, and can be useful to monitor treatment response in canine IMPA.

  7. Early, asymptomatic stage of degenerative joint disease in canine hip joints.

    PubMed

    Lust, G; Summers, B A

    1981-11-01

    The early stages of degenerative joint disease were investigated in coxofemoral joints from dogs with a hereditary predisposition to hip dysplasia. Alterations observed included mild nonsuppurative synovitis, increased volume of both synovial fluid and the ligamentum teres, and focal degenerative articular cartilage lesions. On radiologic examination, subluxation of the femoral head was seen, but only in the most severely affected joints. Synovial inflammation with increased synovial fluid and ligament volumes were indicators of early degenerative joint disease in dogs. These changes seemed to coincide with, or perhaps to precede, microscopic evidence for articular cartilage degeneration and occurred before radiologic abnormalities were detected.

  8. Distribution of lactate dehydrogenase in healthy and degenerative canine stifle joint cartilage.

    PubMed

    Walter, Eveline L C; Spreng, David; Schmöckel, Hugo; Schawalder, Peter; Tschudi, Peter; Friess, Armin E; Stoffel, Michael H

    2007-07-01

    In dogs, degenerative joint diseases (DJD) have been shown to be associated with increased lactate dehydrogenase (LDH) activity in the synovial fluid. The goal of this study was to examine healthy and degenerative stifle joints in order to clarify the origin of LDH in synovial fluid. In order to assess the distribution of LDH, cartilage samples from healthy and degenerative knee joints were investigated by means of light and transmission electron microscopy in conjunction with immunolabeling and enzyme cytochemistry. Morphological analysis confirmed DJD. All techniques used corroborated the presence of LDH in chondrocytes and in the interterritorial matrix of healthy and degenerative stifle joints. Although enzymatic activity of LDH was clearly demonstrated in the territorial matrix by means of the tetrazolium-formazan reaction, immunolabeling for LDH was missing in this region. With respect to the distribution of LDH in the interterritorial matrix, a striking decrease from superficial to deeper layers was present in healthy dogs but was missing in affected joints. These results support the contention that LDH in synovial fluid of degenerative joints originates from cartilage. Therefore, we suggest that (1) LDH is transferred from chondrocytes to ECM in both healthy dogs and dogs with degenerative joint disease and that (2) in degenerative joints, LDH is released from chondrocytes and the ECM into synovial fluid through abrasion of cartilage as well as through enhanced diffusion as a result of increased water content and degradation of collagen.

  9. Co-isolation of Bartonella henselae and Bartonella vinsonii subsp. berkhoffii from blood, joint and subcutaneous seroma fluids from two naturally infected dogs.

    PubMed

    Diniz, Pedro Paulo Vissotto de Paiva; Wood, Michael; Maggi, Ricardo G; Sontakke, Sushama; Stepnik, Matt; Breitschwerdt, Edward B

    2009-09-18

    This report describes the clinical presentation, isolation and treatment of two dogs naturally infected with Bartonella henselae and Bartonella vinsonii subsp. berkhoffii. Chronic and progressive polyarthritis was the primary complaint for dog #1, from which B. henselae and B. vinsonii subsp. berkhoffii were cultured on three independent occasions from blood and joint fluid samples, despite administration of nearly 4 months of non-consecutive antibiotic therapy. A clinically atypical and progressively severe trauma-associated seroma was the primary complaint for dog #2, from which B. henselae and B. vinsonii subsp. berkhoffii were isolated from serum, blood and seroma fluid. Dogs can be co-infected with two Bartonella spp. and infection with these organisms should not be ruled out if specific antibodies are not detected. Specialized culture techniques should be used for isolation and to assess antibiotic efficacy.

  10. Fluid flow analysis of E-glass fiber reinforced pipe joints in oil and gas industry

    NASA Astrophysics Data System (ADS)

    Bobba, Sujith; Leman, Z.; Zainuddin, E. S.; Sapuan, S. M.

    2018-04-01

    Glass Fiber reinforced composites have become increasingly important over the past few years and now they are the first choice materials for fabricating pipes with low weight in combination with high strength and stiffness. In Oil And Gas Industry, The Pipelines transporting heavy crude oil are subjected to variable pressure waves causing fluctuating stress levels in the pipes. Computational Fluid Dynamics (CFD) analysis was performed using solid works flow stimulation software to study the effects of these pressure waves on some specified joints in the pipes. Depending on the type of heavy crude oil being used, the flow behavior indicated a considerable degree of stress levels in certain connecting joints, causing the joints to become weak over a prolonged period of use. This research proposes a new perspective that is still required to be developed regarding the change of the pipe material, fiber winding angle in those specified joints and finally implementing cad wind technology to check the output result of the stress levels so that the life of the pipes can be optimized.

  11. Investigation of particle lateral migration in sample-sheath flow of viscoelastic fluid and Newtonian fluid.

    PubMed

    Yuan, Dan; Zhang, Jun; Yan, Sheng; Peng, Gangrou; Zhao, Qianbin; Alici, Gursel; Du, Hejun; Li, Weihua

    2016-08-01

    In this work, particle lateral migration in sample-sheath flow of viscoelastic fluid and Newtonian fluid was experimentally investigated. The 4.8-μm micro-particles were dispersed in a polyethylene oxide (PEO) viscoelastic solution, and then the solution was injected into a straight rectangular channel with a deionised (DI) water Newtonian sheath flow. Micro-particles suspended in PEO solution migrated laterally to a DI water stream, but migration in the opposite direction from a DI water stream to a PEO solution stream or from one DI water stream to another DI water stream could not be achieved. The lateral migration of particles depends on the viscoelastic properties of the sample fluids. Furthermore, the effects of channel length, flow rate, and PEO concentration were studied. By using viscoelastic sample flow and Newtonian sheath flow, a selective particle lateral migration can be achieved in a simple straight channel, without any external force fields. This particle lateral migration technique could be potentially used in solution exchange fields such as automated cell staining and washing in microfluidic platforms, and holds numerous biomedical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Improving the accuracy of synovial fluid analysis in the diagnosis of prosthetic joint infection with simple and inexpensive biomarkers: C-reactive protein and adenosine deaminase.

    PubMed

    Sousa, R; Serrano, P; Gomes Dias, J; Oliveira, J C; Oliveira, A

    2017-03-01

    The aims of this study were to increase the diagnostic accuracy of the analysis of synovial fluid in the differentiation of prosthetic joint infection (PJI) by the addition of inexpensive biomarkers such as the levels of C-reactive protein (CRP), adenosine deaminase (ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Between January 2013 and December 2015, synovial fluid and removed implants were requested from 143 revision total joint arthroplasties. A total of 55 patients met inclusion criteria of the receipt of sufficient synovial fluid, tissue samples and removed implants for analysis. The diagnosis of PJI followed the definition from a recent International Consensus Meeting to create two groups of patients; septic and aseptic. Using receiver operating characteristic curves we determined the cutoff values and diagnostic accuracy for each marker. There were 23 PJIs and 32 patients with aseptic loosening. The levels of total leucocyte count, proportion of polymorphonuclear leucocytes (PMNs), CRP, ADA and α2M in the synovial fluid were all significantly higher in those with a PJI than in those with aseptic loosening. The levels of procalcitonin were comparable in the two groups. Cutoff values for the optimal performance in the diagnosis of infection were: total leucocyte count > 1463 cells/μL (sensitivity (Sens) 100%, specificity (Spec) 71.9%, positive predictive value (PPV) 71.9%, negative predictive value (NPV) 100%); proportion of PMNs > 81% (Sens 78.3%, Spec 75.0%, PPV 69.2%, NPV 82.8%); CRP > 6.7mg/L (Sens 78.3%, Spec 93.8%, PPV 90.0%, NPV 85.7%); ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%) and α2M > 958 mg/L (Sens 47.8%, Spec 96.9%, PPV 91.7%, NPV 72.1%). The addition of a raised level of CRP or ADA to the total leukocyte count increased the specificity: total leukocyte count > 1463 cells/μL and CRP > 6.7mg/L (Sens 78.3%, Spec 100%, PPV 100%, NPV 86.5%) or with ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%). The total

  13. Fluid leak indicator

    NASA Technical Reports Server (NTRS)

    Anderson, G. E.; Loo, S. (Inventor)

    1985-01-01

    A fluid leak indicator for detecting and indicating leaks in visually inaccessible fluid tubing joints, such as those obstructed by insulation includes a bag system and a wicking system surrounding or wrapping the joints under the visual obstructing material. Leaking fluid is collected in the bag or on the wicking material where it is conducted along the wicking material to a visily accessible capturing transparent indicator bulb for providing a visual indication of the leak without requiring a chemical change in the capturing indicator bulb.

  14. Diagnosis of retrodiscal tissue in painful temporomandibular joint (TMJ) by fluid-attenuated inversion recovery (FLAIR) signal intensity.

    PubMed

    Kuroda, Migiwa; Otonari-Yamamoto, Mika; Sano, Tsukasa; Fujikura, Mamiko; Wakoh, Mamoru

    2014-09-09

    Aims: The purpose of the present study is to analyze the fluid-attenuated inversion recovery (FLAIR) signal intensity of the retrodiscal tissue in a painful temporomandibular joint (TMJ), and to develop a diagnostic system based on FLAIR data. Methodology: The study was based on 33 joints of 17 patients referred for MR imaging of the TMJ. Regions of interest were placed over retrodiscal tissue and gray matter (GM) on FLAIR images. Using signal intensities of GM as reference points, signal intensity ratios (SIR) of retrodiscal tissue were calculated. SIRs in painful TMJ were compared with those in painless TMJ. Wilcoxon's Rank Sum Test was used to analyze the difference in SIRs between the painful and painless groups (P<0·05). Results: The SIRs of retrodiscal tissue were significantly higher in painful joints than in painless joints. Conclusion: FLAIR sequences provide a high signal in patients having painful TMJ, and it suggests that retrodiscal tissue in painful TMJ contains elements such as protein.

  15. Diagnosis of retrodiscal tissue in painful temporomandibular joint (TMJ) by fluid-attenuated inversion recovery (FLAIR) signal intensity.

    PubMed

    Kuroda, Migiwa; Otonari-Yamamoto, Mika; Sano, Tsukasa; Fujikura, Mamiko; Wakoh, Mamoru

    2015-10-01

    The purpose of the present study is to analyze the fluid-attenuated inversion recovery (FLAIR) signal intensity of the retrodiscal tissue in a painful temporomandibular joint (TMJ), and to develop a diagnostic system based on FLAIR data. The study was based on 33 joints of 17 patients referred for MR imaging of the TMJ. Regions of interest were placed over retrodiscal tissue and gray matter (GM) on FLAIR images. Using signal intensities of GM as reference points, signal intensity ratios (SIR) of retrodiscal tissue were calculated. SIRs in painful TMJ were compared with those in painless TMJ. Wilcoxon's Rank Sum Test was used to analyze the difference in SIRs between the painful and painless groups (P<0·05). The SIRs of retrodiscal tissue were significantly higher in painful joints than in painless joints. FLAIR sequences provide a high signal in patients having painful TMJ, and it suggests that retrodiscal tissue in painful TMJ contains elements such as protein.

  16. Supercritical fluid extraction and direct fluid injection mass spectrometry for the determination of trichothecene mycotoxins in wheat samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalinoski, H.T.; Udseth, H.R.; Wright, B.W.

    1986-10-01

    The application of on-line supercritical fluid extraction with chemical ionization mass spectrometry and collision induced dissociation tandem mass spectrometry for the rapid identification of parts-per-million levels of several trichothecene mycotoxins is demonstrated. Supercritical carbon dioxide is shown to allow identification of mycotoxins with minimum sample handling in complex natural matrices (e.g., wheat). Tandem mass spectrometry techniques are employed for unambiguous identification of compounds of varying polarity, and false positives from isobaric compounds are avoided. Capillary column supercritical fluid chromatography-mass spectrometry of a supercritical fluid extract of the same sample was also performed and detection limits in the parts-per-billion range appearmore » feasible.« less

  17. Effects of glucosamine-chondroitin combination on synovial fluid IL-1β, IL-6, TNF-α and PGE2 levels in internal derangements of temporomandibular joint

    PubMed Central

    Esen, Emin; Tatli, Ufuk

    2015-01-01

    Background The aim of the present study was to evaluate the effects of glucosamine-chondroitin sulphate combination on internal derangements of temporomandibular joint in clinical and biochemical manners. Material and Methods This randomized clinical study included 31 cases reporting joint tenderness, in which disc displacement was detected on MR imaging. In all patients, synovial fluid sampling was performed under local anesthesia. In the study group, the patients were prescribed a combination of 1500 mg glucosamine and 1200 mg chondroitin sulphate, while patients in the control group were only prescribed 50 mg tramadol HCl (twice daily) for pain control. After 8 weeks, synovial fluid sampling was repeated in the same manner. The levels of pain, maximum mouth opening (MMO), synovial fluid IL-1ß, IL-6, TNF-α and PGE2 measured before and after pharmacological intervention were compared. Results The reduction in pain levels was significant in both groups. There was no significant difference between two groups in terms of pain reduction. The improvement in MMO was significant in the study group but it was not in the control group. The MMO improvement was significantly higher in the study group compared to the control group. In the study group, significant decrease was observed in PGE2 level, while the decreases in IL-1β, IL-6 and TNF-α levels were not significant. In the control group, no significant decrease was observed in any of the inflammatory cytokines after 8 weeks, moreover IL-1ß and IL-6 levels were increased. Alterations of IL-1ß and IL-6 levels were significant in study group while TNF-α and PGE2 levels were not, compared to control group. Conclusions In conclusion, these results might suggest that glucosamine-chondroitin combination significantly increases the MMO and decreases the synovial fluid IL1β and IL6 levels in internal derangements of TMJ compared to tramadol. The modifications of synovial fluid TNF-α and PGE2 levels do not reach

  18. The influence of the acetabular labrum seal, intact articular superficial zone and synovial fluid thixotropy on squeeze-film lubrication of a spherical synovial joint.

    PubMed

    Hlavácek, M

    2002-10-01

    A model of synovial fluid (SF) filtration by articular cartilage (AC) in a step-loaded spherical synovial joint at rest is presented. The effects of joint pathology (such as a depleted acetabular labrum, a depleted cartilage superficial zone consistent with early osteoarthritis and an inflammatory SF) on the squeezed synovial film are also investigated. Biphasic mixture models for AC (ideal fluid and elastic porous transversely isotropic two-layer matrix) and for SF (ideal and thixotropic fluids) are applied and the following results are obtained. If the acetabular labrum is able to seal the pressurised SF between the articular surfaces (as in the normal hip joint), the fluid in the synovial film and in the cartilage within the labral ring is homogeneously pressurised. The articular surfaces remain separated by a fluid film for minutes. If the labrum is destroyed or absent and the SF can escape across the contact edge, the fluid pressure is non-homogeneous and with a small jump at the articular surface at the very moment of load application. The ensuing synovial film filtration by porous cartilage is lower for the normal cartilage (with the intact superficial zone) than if this zone is already depleted or rubbed off as in the early stage of primary osteoarthritis. Compared with the inflammatory (Newtonian) SF, the normal (thixotropic) fluid applies favourably in the squeezed film near the contact centre only, yielding a thicker SF film there, but not affecting the minimum thickness in the fluid film profile at a fixed time. For all that, in the unsealed case for both the normal and pathological joint, the macromolecular concentration of the hyaluronic acid-protein complex in the synovial film quickly increases due to the filtration in the greater part of the contact. A stable synovial gel film, thick on the order of 10(-7)m, protecting the articular surfaces from the intimate contact, is formed within a couple of seconds. Boundary lubrication by the synovial gel is

  19. Helium isotopes in matrix pore fluids from SAFOD drill core samples suggest mantle fluids cannot be responsible for fault weakening

    NASA Astrophysics Data System (ADS)

    Ali, S.; Stute, M.; Torgersen, T.; Winckler, G.

    2008-12-01

    To quantify fluid flow in the San Andreas Fault (SAF) (and since direct fracture fluid sampling of the fault zone was not available), we have adapted a method to extract rare gases from matrix fluids of whole rocks by diffusion. Helium was measured on drill core samples obtained from 3054 m (Pacific Plate) to 3990 m (North American Plate) through the San Andreas Fault Zone (SAFZ) ~3300 m during SAFOD Phases I (2004), II (2005), III (2007). Samples were typically collected as 2.54 cm diameter subcores drilled into the ends of the cores, or from the core catcher and drillcore fragments within <2hr after core recovery. The samples were placed into ultra high vacuum stainless steel containers, flushed with ultra high purity nitrogen and immediately evacuated. Helium isotopes of the extracted matrix pore fluids and the solid matrix were determined by mass spectrometery at LDEO. Matrix porefluid 3He/4He ratios are ~0.4 - 0.5xRa (Ra: atmospheric 3He/4He = 1.384 x 10-6) in the Pacific Plate, increasing toward the SAFZ, while pore fluids in the North American Plate have a 3He/4He range of 0.7-0.9Ra, increasing away from the SAFZ (consistent with results from mud gas samples (Wiersberg and Erzinger, 2007) and direct fluid samples (Kennedy et al., 2007)). Helium isotope ratios of the solid matrix are less than 0.06Ra across the SAF in samples from both the North American and the Pacific plates, thereby excluding the host matrix as source for the enhanced isotopic signature. If the system is assumed to be in steady state, then the flux of mantle helium must be from the North American Plate to the Pacific plate. The steeper gradient in the Pacific Plate relative to the North American plate is consistent with a porosity corrected effective diffusivity. The source for this mantle helium in the North American Plate is likely related to a low crustal conductivity zone identified by magnetotelluric signals (Becken et al., 2008) that provides a channel for transport of mantle helium

  20. Fluid leak indicator

    NASA Technical Reports Server (NTRS)

    Anderson, George E. (Inventor); Loo, Shu (Inventor)

    1989-01-01

    A fluid leak indicator (30) for detecting and indicating leaks in visually inaccessible fluid tubing joints (20, 21), such as those obstructed by insulation (24), includes a bag system (25) and a wicking system (30) surrounding or wrapping the joints (20, 21) under the visual obstructing material (24). Leaking fluid is collected in the bag (25) or on the wicking material (34) where it is conducted along the wicking material (34) to a visibly accessible capturing transparent indicator bulb (35) for providing a visual indication of the leak without requiring a chemical change in the capturing indicator bulb (35).

  1. Fluid sample collection and distribution system. [qualitative analysis of aqueous samples from several points

    NASA Technical Reports Server (NTRS)

    Brooks, R. L. (Inventor)

    1979-01-01

    A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.

  2. Synovial Fluid α-Defensin as a Biomarker for Peri-Prosthetic Joint Infection: A Systematic Review and Meta-Analysis.

    PubMed

    Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang

    Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.

  3. Comparison of synovial fluid culture and 16S rRNA PCR in dogs with suspected septic arthritis.

    PubMed

    Scharf, V F; Lewis, D D; Wellehan, J F; Wamsley, H L; Richardson, R

    2015-06-01

    To prospectively compare the sensitivity and specificity of 16S rRNA PCR with culture for identifying the causative organism in synovial fluid obtained from dogs with suspected septic arthritis. Synovial fluid cytology, PCR analysis and aerobic, anaerobic and Mycoplasma culture of samples from the affected joints of 18 dogs presenting with suspected septic arthritis were performed. Synovial fluid samples from the corresponding contralateral joints of 7 dogs were also analysed as negative controls. There was no significant difference between the sensitivity of bacterial detection via culture (63.2%) versus PCR (73.7%) of synovial fluid (P=0.728) or between culture and combined PCR and culture (89.5%) of synovial fluid (P=0.124). The specificity of PCR (42.9%) was significantly lower than culture specificity (100%) (P=0.07). Although 16S PCR may hold potential as an ancillary diagnostic test for identifying the causative organism in dogs with septic arthritis, our study failed to demonstrate improved accuracy compared with traditional synovial fluid culture. © 2015 Australian Veterinary Association.

  4. Nociceptive role of substance-P in the knee joint of a patient with congenital insensitivity to pain.

    PubMed

    Derwin, K A; Glover, R A; Wojtys, E M

    1994-01-01

    This case report describes the immunocytochemical examination of tissue from a 9-year-old black child diagnosed with congenital insensitivity to pain at age 5. A recent fall and resulting patella fracture required surgical treatment. Biopsies of the distal pole and surrounding soft tissue, as well as a sample of his patellofemoral joint fluid, were taken at the time of partial patellectomy and analyzed for substance-P (SP). Morphologic staining of the patella showed a grossly degenerated patellofemoral articular surface. Examination of tissue sections stained either immunocytochemically with diaminobenzidine DAB or by a rhodamine fluorescent labeling technique showed no evidence of SP-positive nerve fibers. Furthermore, only a trace amount of SP (7.29 pg/ml) was detected in a sample of the patient's knee joint synovial fluid. This patient's absence of pain sensation in conjunction with the absence of SP nerve fibers in stained patella sections and identification of only trace levels of SP in his synovial fluid, further implicates this neuropeptide in nociceptive innervation of diarthrodial joints.

  5. The search for and analysis of direct samples of early Solar System aqueous fluids.

    PubMed

    Zolensky, Michael E; Bodnar, Robert J; Yurimoto, Hisayoshi; Itoh, Shoichi; Fries, Marc; Steele, Andrew; Chan, Queenie H-S; Tsuchiyama, Akira; Kebukawa, Yoko; Ito, Motoo

    2017-05-28

    We describe the current state of the search for direct, surviving samples of early, inner Solar System fluids-fluid inclusions in meteorites. Meteoritic aqueous fluid inclusions are not rare, but they are very tiny and their characterization is at the state of the art for most analytical techniques. Meteoritic fluid inclusions offer us a unique opportunity to study early Solar System brines in the laboratory. Inclusion-by-inclusion analyses of the trapped fluids in carefully selected samples will, in the immediate future, provide us detailed information on the evolution of fluids as they interacted with anhydrous solid materials. Thus, real data can replace calculated fluid compositions in thermochemical calculations of the evolution of water and aqueous reactions in comets, asteroids, moons and the terrestrial planets.This article is part of the themed issue 'The origin, history and role of water in the evolution of the inner Solar System'. © 2017 The Author(s).

  6. Influence of Sampling on the Determination of Warfarin and Warfarin Alcohols in Oral Fluid

    PubMed Central

    Lomonaco, Tommaso; Ghimenti, Silvia; Piga, Isabella; Biagini, Denise; Onor, Massimo; Fuoco, Roger; Di Francesco, Fabio

    2014-01-01

    Background and Objective The determination of warfarin, RS/SR- and RR/SS-warfarin alcohols in oral fluid may offer additional information to the INR assay. This study aimed to establish an optimized sampling technique providing the best correlation between the oral fluid and the unbound plasma concentrations of these compounds. Materials and Methods Samples of non-stimulated and stimulated oral fluid, and blood were collected from 14 patients undergoing warfarin therapy. After acidification, analytes were extracted with a dichloromethane/hexane mixture and determined by HPLC with fluorescence detection. Plasma samples were also ultrafiltered for the determination of the unbound fraction. The chromatographic separation was carried out in isocratic conditions with a phosphate buffer/methanol mobile phase on a C-18 reversed-phase column. The absence of interfering compounds was verified by HPLC-ESI-Q-TOF. Results Stimulation generally increased the oral fluid pH to values close to blood pH in about 6 minutes. The concentration of warfarin and RS/SR-warfarin alcohols in oral fluid followed the same trend, whereas the concentration of RR/SS-warfarin alcohols was not affected. Six minute stimulation with chewing gum followed by collection with a polyester swab was the best sampling procedure, with a good repeatability (RSD <10%) and relatively low inter-subject variability (RSD  = 30%) of the oral fluid to plasma ratio. This procedure provided strong correlations between the measured oral fluid and unbound plasma concentration of warfarin (r  =  0.92, p <0.001) and RS/SR-warfarin alcohols (r  =  0.84, p <0.001), as well as between stimulated oral fluid and total plasma concentration of warfarin (r  =  0.78, p <0.001) and RS/SR-warfarin alcohols (r  =  0.81, p <0.001). Conclusion The very good correlation between oral fluid and unbound plasma concentration of warfarin and RS/SR-warfarin alcohols suggests that oral fluid analysis could provide

  7. Analysis of Direct Samples of Early Solar System Aqueous Fluids

    NASA Technical Reports Server (NTRS)

    Zolensky, Michael E.; Bodnar, R J.; Fedele, L.; Yurimoto,H.; Itoh, S.; Fries, M.; Steele, A.

    2012-01-01

    Over the past three decades we have become increasingly aware of the fundamental importance of water, and aqueous alteration, on primitive solar-system bodies. Some carbonaceous and ordinary chondrites have been altered by interactions with liquid water within the first 10 million years after formation of their parent asteroids. Millimeter to centimeter-sized aggregates of purple halite containing aqueous fluid inclusions were found in the matrix of two freshly-fallen brecciated H chondrite falls, Monahans (1998, hereafter simply "Monahans") (H5) and Zag (H3-6) (Zolensky et al., 1999; Whitby et al., 2000; Bogard et al., 2001) In order to understand origin and evolution of the aqueous fluids inside these inclusions we much measure the actual fluid composition, and also learn the O and H isotopic composition of the water. It has taken a decade for laboratory analytical techniques to catch up to these particular nanomole-sized aqueous samples. We have recently been successful in (1) measuring the isotopic composition of H and O in the water in a few fluid inclusions from the Zag and Monahans halite, (2) mineralogical characterization of the solid mineral phases associated with the aqueous fluids within the halite, and (3) the first minor element analyses of the fluid itself. A Cameca ims-1270 equipped with a cryo-sample-stage of Hokkaido University was specially prepared for the O and H isotopic measurements. The cryo-sample-stage (Techno. I. S. Corp.) was cooled down to c.a. -190 C using liquid nitrogen at which the aqueous fluid in inclusions was frozen. We excavated the salt crystal surfaces to expose the frozen fluids using a 15 keV Cs+ beam and measured negative secondary ions. The secondary ions from deep craters of approximately 10 m in depth emitted stably but the intensities changed gradually during measurement cycles because of shifting states of charge compensation, resulting in rather poor reproducibility of multiple measurements of standard fluid

  8. The effect of brazing parameters on corrosion behavior of brazed aluminum joints

    NASA Astrophysics Data System (ADS)

    Ghasimakbari, Farzam; Hadian, Ali Mohammad; Ershadrad, Soheil; Omidazad, Amir Mansour

    2018-01-01

    Fluid transmission pipes made of aluminum are widely used in petrochemical industries. For many applications, they have to be brazed to each other. The brazed joints, in many cases, are encountered with corrosive medias. This paper reports a part of a work to investigate the corrosion behavior of brazed AA6061 using AA4047 as filler metal with and without the use of flux under different brazing atmospheres. The samples brazed under air, vacuum, argon, and hydrogen atmospheres. The interfacial area of the joints was examined to ensure being free of any defects. The sides of each test piece were covered with an insulator and the surface of the joint was encountered to polarization test. The results revealed a significant difference of corrosion resistance. The samples that brazed under argon and hydrogen atmospheres had better corrosion resistance than other samples. The microstructure of the corroded joints revealed that the presence of defects, impurities due to use of flux and depth of filter metal penetration in base metal are crucial variables on the corrosion resistance of the joints.

  9. Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

    PubMed

    Anthony, T Renée; Sleeth, Darrah; Volckens, John

    2016-01-01

    In the U.S., most industrial hygiene practitioners continue to rely on the closed-face cassette (CFC) to assess worker exposures to hazardous dusts, primarily because ease of use, cost, and familiarity. However, mass concentrations measured with this classic sampler underestimate exposures to larger particles throughout the inhalable particulate mass (IPM) size range (up to aerodynamic diameters of 100 μm). To investigate whether the current 37-mm inlet cap can be redesigned to better meet the IPM sampling criterion, computational fluid dynamics (CFD) models were developed, and particle sampling efficiencies associated with various modifications to the CFC inlet cap were determined. Simulations of fluid flow (standard k-epsilon turbulent model) and particle transport (laminar trajectories, 1-116 μm) were conducted using sampling flow rates of 10 L min(-1) in slow moving air (0.2 m s(-1)) in the facing-the-wind orientation. Combinations of seven inlet shapes and three inlet diameters were evaluated as candidates to replace the current 37-mm inlet cap. For a given inlet geometry, differences in sampler efficiency between inlet diameters averaged less than 1% for particles through 100 μm, but the largest opening was found to increase the efficiency for the 116 μm particles by 14% for the flat inlet cap. A substantial reduction in sampler efficiency was identified for sampler inlets with side walls extending beyond the dimension of the external lip of the current 37-mm CFC. The inlet cap based on the 37-mm CFC dimensions with an expanded 15-mm entry provided the best agreement with facing-the-wind human aspiration efficiency. The sampler efficiency was increased with a flat entry or with a thin central lip adjacent to the new enlarged entry. This work provides a substantial body of sampling efficiency estimates as a function of particle size and inlet geometry for personal aerosol samplers.

  10. Microbial diversity within Juan de Fuca ridge basement fluids sampled from oceanic borehole observatories

    NASA Astrophysics Data System (ADS)

    Jungbluth, S.; Bowers, R.; Lin, H.; Hsieh, C.; Cowen, J. P.; Rappé, M.

    2012-12-01

    Three generations of sampling and instrumentation platforms known as Circulation Obviation Retrofit Kit (CORK) observatories affixed to Ocean Drilling Program (ODP) and Integrated Ocean Drilling Program (IODP) boreholes are providing unrivaled access to fluids originating from 1.2-3.5 million-years (Myr) old basaltic crust of the eastern flank of the Juan de Fuca ridge. Borehole fluid samples obtained via a custom seafloor fluid pumping and sampling system coupled to CORK continuous fluid delivery lines are yielding critical insights into the biogeochemistry and nature of microbial life inhabiting the sediment-covered basement environment. Direct microscopic enumeration revealed microbial cell abundances that are 2-41% of overlying bottom seawater. Snapshots of basement fluid microbial diversity and community structure have been obtained through small subunit ribosomal RNA (SSU rRNA) gene cloning and sequencing from five boreholes that access a range of basement ages and temperatures at the sediment-basement interface. SSU rRNA gene clones were derived from four different CORK installations (1026B, 1301A, 1362A, and 1362B) accessing relatively warmer (65°C) and older (3.5 Myr) ridge flank, and one location (1025C) accessing relatively cooler (39°C) and younger (1.2 Myr) ridge flank, revealing that warmer basement fluids had higher microbial diversity. A sampling time-series collected from borehole 1301A has revealed a microbial community that is temporally variable, with the dominant lineages changing between years. Each of the five boreholes sampled contained a unique microbial assemblage, however, common members are found from both cultivated and uncultivated lineages within the archaeal and bacterial domains, including meso- and thermophilic microbial lineages involved with sulfur cycling (e.g Thiomicrospira, Sulfurimonas, Desulfocapsa, Desulfobulbus). In addition, borehole fluid environmental gene clones were also closely related to uncultivated lineages

  11. Potential artifacts associated with historical preparation of joint compound samples and reported airborne asbestos concentrations.

    PubMed

    Brorby, G P; Sheehan, P J; Berman, D W; Bogen, K T; Holm, S E

    2011-05-01

    Airborne samples collected in the 1970s for drywall workers using asbestos-containing joint compounds were likely prepared and analyzed according to National Institute of Occupational Safety and Health Method P&CAM 239, the historical precursor to current Method 7400. Experimentation with a re-created, chrysotile-containing, carbonate-based joint compound suggested that analysis following sample preparation by the historical vs. current method produces different fiber counts, likely because of an interaction between the different clearing and mounting chemicals used and the carbonate-based joint compound matrix. Differences were also observed during analysis using Method 7402, depending on whether acetic acid/dimethylformamide or acetone was used during preparation to collapse the filter. Specifically, air samples of sanded chrysotile-containing joint compound prepared by the historical method yielded fiber counts significantly greater (average of 1.7-fold, 95% confidence interval: 1.5- to 2.0-fold) than those obtained by the current method. In addition, air samples prepared by Method 7402 using acetic acid/dimethylformamide yielded fiber counts that were greater (2.8-fold, 95% confidence interval: 2.5- to 3.2-fold) than those prepared by this method using acetone. These results indicated (1) there is an interaction between Method P&CAM 239 preparation chemicals and the carbonate-based joint compound matrix that reveals fibers that were previously bound in the matrix, and (2) the same appeared to be true for Method 7402 preparation chemicals acetic acid/dimethylformamide. This difference in fiber counts is the opposite of what has been reported historically for samples of relatively pure chrysotile dusts prepared using the same chemicals. This preparation artifact should be considered when interpreting historical air samples for drywall workers prepared by Method P&CAM 239. Copyright © 2011 JOEH, LLC

  12. Disclosing the temperature of columnar jointing in lavas.

    PubMed

    Lamur, Anthony; Lavallée, Yan; Iddon, Fiona E; Hornby, Adrian J; Kendrick, Jackie E; von Aulock, Felix W; Wadsworth, Fabian B

    2018-04-12

    Columnar joints form by cracking during cooling-induced contraction of lava, allowing hydrothermal fluid circulation. A lack of direct observations of their formation has led to ambiguity about the temperature window of jointing and its impact on fluid flow. Here we develop a novel thermo-mechanical experiment to disclose the temperature of columnar jointing in lavas. Using basalts from Eyjafjallajökull volcano (Iceland) we show that contraction during cooling induces stress build-up below the solidus temperature (980 °C), resulting in localised macroscopic failure between 890 and 840 °C. This temperature window for incipient columnar jointing is supported by modelling informed by mechanical testing and thermal expansivity measurements. We demonstrate that columnar jointing takes place well within the solid state of volcanic rocks, and is followed by a nonlinear increase in system permeability of <9 orders of magnitude during cooling. Columnar jointing may promote advective cooling in magmatic-hydrothermal environments and fluid loss during geothermal drilling and thermal stimulation.

  13. Efficient computation of the joint sample frequency spectra for multiple populations.

    PubMed

    Kamm, John A; Terhorst, Jonathan; Song, Yun S

    2017-01-01

    A wide range of studies in population genetics have employed the sample frequency spectrum (SFS), a summary statistic which describes the distribution of mutant alleles at a polymorphic site in a sample of DNA sequences and provides a highly efficient dimensional reduction of large-scale population genomic variation data. Recently, there has been much interest in analyzing the joint SFS data from multiple populations to infer parameters of complex demographic histories, including variable population sizes, population split times, migration rates, admixture proportions, and so on. SFS-based inference methods require accurate computation of the expected SFS under a given demographic model. Although much methodological progress has been made, existing methods suffer from numerical instability and high computational complexity when multiple populations are involved and the sample size is large. In this paper, we present new analytic formulas and algorithms that enable accurate, efficient computation of the expected joint SFS for thousands of individuals sampled from hundreds of populations related by a complex demographic model with arbitrary population size histories (including piecewise-exponential growth). Our results are implemented in a new software package called momi (MOran Models for Inference). Through an empirical study we demonstrate our improvements to numerical stability and computational complexity.

  14. Efficient computation of the joint sample frequency spectra for multiple populations

    PubMed Central

    Kamm, John A.; Terhorst, Jonathan; Song, Yun S.

    2016-01-01

    A wide range of studies in population genetics have employed the sample frequency spectrum (SFS), a summary statistic which describes the distribution of mutant alleles at a polymorphic site in a sample of DNA sequences and provides a highly efficient dimensional reduction of large-scale population genomic variation data. Recently, there has been much interest in analyzing the joint SFS data from multiple populations to infer parameters of complex demographic histories, including variable population sizes, population split times, migration rates, admixture proportions, and so on. SFS-based inference methods require accurate computation of the expected SFS under a given demographic model. Although much methodological progress has been made, existing methods suffer from numerical instability and high computational complexity when multiple populations are involved and the sample size is large. In this paper, we present new analytic formulas and algorithms that enable accurate, efficient computation of the expected joint SFS for thousands of individuals sampled from hundreds of populations related by a complex demographic model with arbitrary population size histories (including piecewise-exponential growth). Our results are implemented in a new software package called momi (MOran Models for Inference). Through an empirical study we demonstrate our improvements to numerical stability and computational complexity. PMID:28239248

  15. Analysis of lactate concentrations in canine synovial fluid.

    PubMed

    Proot, J L J; de Vicente, F; Sheahan, D E

    2015-01-01

    To report synovial fluid lactate concentrations in normal and pathological canine joints. Controlled, prospective study. Lactate was measured in synovial fluid using a hand-held meter and the rest of the fluid was sent to a commercial laboratory for analysis. Samples were divided into four groups; group 1: control, group 2: osteoarthritis, group 3: immune-mediated inflammatory arthritis, and group 4: septic arthritis. Statistical analysis was performed to compare lactate concentrations between the four groups and to examine the predictive value of lactate in the diagnosis of septic arthritis. A correlation was sought between synovial fluid lactate and synovial fluid total nucleated cell count and total protein. Seventy-four samples were investigated from 55 dogs. Statistical analysis found that lactate concentrations were significantly higher in the septic arthritis group than in each of the other three groups. No significant correlation could be found between synovial fluid lactate concentrations and synovial fluid total nucleated cell count or synovial fluid total protein. Lactate concentration was found to be a useful predictor of septic arthritis, with a low concentration pointing towards exclusion rather than a high concentration to the diagnosis of septic arthritis. Synovial fluid lactate concentration is not a good marker for osteoarthritis or immune-mediated inflammatory arthritis, but it is significantly increased in septic arthritis and could help the clinician in ruling out this condition in a quick and cost-effective way.

  16. Novel on-demand droplet generation for selective fluid sample extraction

    PubMed Central

    Lin, Robert; Fisher, Jeffery S.; Simon, Melinda G.; Lee, Abraham P.

    2012-01-01

    A novel microfluidic device enabling selective generation of droplets and encapsulation of targets is presented. Unlike conventional methods, the presented mechanism generates droplets with unique selectivity by utilizing a K-junction design. The K-junction is a modified version of the classic T-junction with an added leg that serves as the exit channel for waste. The dispersed phase fluid enters from one diagonal of the K and exits the other diagonal while the continuous phase travels in the straight leg of the K. The intersection forms an interface that allows the dispersed phase to be controllably injected through actuation of an elastomer membrane located above the inlet channel near the interface. We have characterized two critical components in controlling the droplet size—membrane actuation pressure and timing as well as identified the region of fluid in which the droplet will be formed. This scheme will have applications in fluid sampling processes and selective encapsulation of materials. Selective encapsulation of a single cell from the dispersed phase fluid is demonstrated as an example of functionality of this design. PMID:22655015

  17. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.

    PubMed

    Jin, Z M; Dowson, D; Fisher, J

    1997-01-01

    Lubrication mechanisms and contact mechanics have been analysed for total hip joint replacements made from hard bearing surfaces such as metal-on-metal and ceramic-on-ceramic. A similar analysis for ultra-high molecular weight polyethylene (UHMWPE) against a hard bearing surface has also been carried out and used as a reference. The most important factor influencing the predicted lubrication film thickness has been found to be the radial clearance between the ball and the socket. Full fluid film lubrication may be achieved in these hard/hard bearings provided that the surface finish of the bearing surface and the radial clearance are chosen correctly and maintained. Furthermore, there is a close relation between the predicted contact half width and the predicted lubrication film thickness. Therefore, it is important to analyse the contact mechanics in artificial hip joint replacements. Practical considerations of manufacturing these bearing surfaces have also been discussed.

  18. Oral fluid samples used for PRRSV acclimatization program and sow performance monitoring in endemic PRRS-positive farms.

    PubMed

    Woonwong, Yonlayong; Kedkovid, Roongtham; Arunorat, Jirapat; Sirisereewan, Chaitawat; Nedumpun, Teerawut; Poonsuk, Korakrit; Panyasing, Yaowalak; Poolperm, Pariwat; Boonsoongnern, Alongkot; Thanawongnuwech, Roongroje

    2018-02-01

    An effective gilt acclimatization program is one of the most important management strategies for controlling porcine reproductive and respiratory syndrome virus (PRRSV) infection. Recently, oral fluid samples have been used as alternative diagnostic samples for various swine diseases. This study utilized oral fluids for PRRSV monitoring during the gilt acclimatization period in PRRSV endemic farms. The study was performed in two selected commercial breeding herds (farm A and farm B). PRRSV RNA and PRRSV-specific antibodies were monitored using oral fluid and serum samples. Sow performance parameters related to PRRSV infection were recorded and assessed. After PRRSV exposure during acclimatization, viral RNA was demonstrated in oral fluids from 1 to 10 weeks post-exposure (WPE). PRRSV RNA was detected in serum at 1 and 4 WPE in farm A and at 1, 4, 8, and 12 WPE in farm B. Prolonged viremia of gilts from farm B was possibly due to re-infection (within the herd) and later, reproductive problems were found in the breeding herd. The correlation of PRRSV RNA concentration in oral fluids and serum was evident. The S/P ratio values of PRRSV antibodies in oral fluid samples were higher and had similar patterns of antibody responses to the serum samples. The results suggest that the use of oral fluid samples for PRRSV monitoring during gilt acclimatization in endemic farms is effective, convenient, practical, and economical and would be most beneficial when used with other parameters.

  19. Hyaluronic acid synthase-2 gene transfer into the joints of Beagles by use of recombinant adeno-associated viral vectors.

    PubMed

    Kyostio-Moore, Sirkka; Berthelette, Patricia; Cornell, Cathleen Sookdeo; Nambiar, Bindu; Figueiredo, Monica Dias

    2018-05-01

    OBJECTIVE To evaluate gene transfer of recombinant adeno-associated viral (rAAV) vectors with AAV2 or AAV5 capsid and encoding hyaluronic acid (HA) synthase-2 (HAS2) into joints of healthy dogs. ANIMALS 22 purpose-bred Beagles. PROCEDURES Plasmid expression cassettes encoding canine HAS2 (cHAS2) were assessed in vitro for concentration and molecular size of secreted HA. Thereafter, rAAV2-cHAS2 vectors at 3 concentrations and rAAV5-cHAS2 vectors at 1 concentration were each administered intra-articularly into the left stifle joint of 5 dogs; 2 dogs received PBS solution instead. Synovial fluid HA concentration and serum and synovial fluid titers of neutralizing antibodies against AAV capsids were measured at various points. Dogs were euthanized 28 days after treatment, and cartilage and synovium samples were collected for vector DNA and mRNA quantification and histologic examination. RESULTS Cell transfection with plasmids encoding cHAS2 resulted in an increase in production and secretion of HA in vitro. In vivo, the rAAV5-cHAS2 vector yielded uniform genome transfer and cHAS2 expression in collected synovium and cartilage samples. In contrast, rAAV2-cHAS2 vectors were detected inconsistently in synovium and cartilage samples and failed to produce clear dose-related responses. Histologic examination revealed minimal synovial inflammation in joints injected with rAAV vectors. Neutralizing antibodies against AAV capsids were detected in serum and synovial fluid samples from all vector-treated dogs. CONCLUSIONS AND CLINICAL RELEVANCE rAAV5-mediated transfer of the gene for cHAS2 into healthy joints of dogs by intra-articular injection appeared safe and resulted in vector-derived cHAS2 production by synoviocytes and chondrocytes. Whether this treatment may increase HA production by synoviocytes and chondrocytes in osteoarthritic joints remains to be determined.

  20. Comparison of microdialysis sampling perfusion fluid components on the foreign body reaction in rat subcutaneous tissue.

    PubMed

    Keeler, Geoffrey D; Durdik, Jeannine M; Stenken, Julie A

    2014-06-16

    Microdialysis sampling is a commonly used technique for collecting solutes from the extracellular space of tissues in laboratory animals and humans. Large molecular weight solutes can be collected using high molecular weight cutoff (MWCO) membranes (100kDa or greater). High MWCO membranes require addition of high molecular weight dextrans or albumin to the perfusion fluid to prevent fluid loss via ultrafiltration. While these perfusion fluid additives are commonly used during microdialysis sampling, the tissue response to the loss of these compounds across the membrane is poorly understood. Tissue reactions to implanted microdialysis sampling probes containing different microdialysis perfusion fluids were compared over a 7-day time period in rats. The base perfusion fluid was Ringer's solution supplemented with either bovine serum albumin (BSA), rat serum albumin (RSA), Dextran-70, or Dextran-500. A significant inflammatory response to Dextran-70 was observed. No differences in the tissue response between BSA and RSA were observed. Among these agents, the BSA, RSA, and Dextran-500 produced a significantly reduced inflammatory response compared to the Dextran-70. This work demonstrates that use of Dextran-70 in microdialysis sampling perfusion fluids should be eliminated and replaced with Dextran-500 or other alternatives. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Fluid inclusions in Martian samples: Clues to early crustal development and the hydrosphere

    NASA Technical Reports Server (NTRS)

    Brown, Philip E.

    1988-01-01

    Major questions about Mars that could be illuminated by examining fluid inclusions in Martian samples include: (1) the nature, extent and timing of development (and decline) of the hydrosphere that existed on the planet; and (2) the evolution of the crust. Fluid inclusion analyses of appropriate samples could provide critical data to use in comparison with data derived from analogous terrestrial studies. For this study, sample handling and return restrictions are unlikely to be as restrictive as the needs of other investigators. The main constraint is that the samples not be subjected to excessively high temperatures. An aqueous fluid inclusion trapped at elevated pressure and temperature will commonly consist of liquid water and water vapor at room temperature. Heating (such as is done in the laboratory to fix P-V-T data for the inclusion) results in moderate pressure increases up to the liquid-vapor homogenization temperature followed by a sharp increase in pressure with continued heating because the inclusion is effectively a fixed volume system. This increased pressure can rupture the inclusion; precise limits are dependent on size, shape, and composition as well as the host material.

  2. Laboratory evaluation and interpretation of synovial fluid.

    PubMed

    MacWilliams, Peter S; Friedrichs, Kristen R

    2003-01-01

    Canine and feline joint disease can be a primary disorder limited to joints or a manifestation of multisystemic disease. Collection and analysis of joint fluid provides valuable information for the diagnosis, prognosis, and treatment of diseases that affect the joint space. The cytologic recognition of the cellular components and infectious agents in synovial fluid categorizes the cell response and differentiates inflammatory and noninflammatory joint disorders. This information is supported by the cell counts, protein content, mucin clot test, bacterial culture, and serologic tests for infectious or immune-mediated disease. These results are integrated with the clinical history, physical examination, radiographic findings, and ancillary test results to arrive at a diagnosis and treatment plan.

  3. Presumed lupus erythematosus cells identified in bronchoalveolar lavage fluid from a Mexican Hairless dog.

    PubMed

    Black, Laura J; Hechler, Ashley C; Duffy, Maura E; Beatty, Sarah S K

    2017-06-01

    A neutered male Mexican Hairless dog was presented for generalized weight loss and weakness. Initial laboratory testing and diagnostic imaging revealed thrombocytopenia and an interstitial to miliary lung pattern affecting all lung fields. Mild joint effusion was found on physical examination affecting the stifle, tarsal, carpal, and elbow joints. Examination of synovial fluid demonstrated an inflammatory polyarthropathy in 3 joints. Cytocentrifuged and direct preparations of the bronchoalveolar lavage (BAL) fluid sample were made and cells consistent with lupus erythematosus (LE) cells and ragocytes were found. Based on these findings, the anti-nuclear antibody (ANA) titer was determined as 1:640. A clinical diagnosis of systemic LE was made based on the satisfaction of 2 major criteria (thrombocytopenia and inflammatory polyarthritis), 4 minor criteria (central nervous system signs, lymphadenopathy, fever of unknown origin, and pleuritis), positive ANA titer, and the identification of presumed LE cells in BAL fluid. This case report highlights a novel finding of LE cells in respiratory secretions and provides a review of diagnostic criteria of systemic LE. © 2017 American Society for Veterinary Clinical Pathology.

  4. Liquid Microjunction Surface Sampling Probe Fluid Dynamics: Computational and Experimental Analysis of Coaxial Intercapillary Positioning Effects on Sample Manipulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElNaggar, Mariam S; Barbier, Charlotte N; Van Berkel, Gary J

    A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means formore » visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formationmode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.« less

  5. Joint analysis of binary and quantitative traits with data sharing and outcome-dependent sampling.

    PubMed

    Zheng, Gang; Wu, Colin O; Kwak, Minjung; Jiang, Wenhua; Joo, Jungnam; Lima, Joao A C

    2012-04-01

    We study the analysis of a joint association between a genetic marker with both binary (case-control) and quantitative (continuous) traits, where the quantitative trait values are only available for the cases due to data sharing and outcome-dependent sampling. Data sharing becomes common in genetic association studies, and the outcome-dependent sampling is the consequence of data sharing, under which a phenotype of interest is not measured for some subgroup. The trend test (or Pearson's test) and F-test are often, respectively, used to analyze the binary and quantitative traits. Because of the outcome-dependent sampling, the usual F-test can be applied using the subgroup with the observed quantitative traits. We propose a modified F-test by also incorporating the genotype frequencies of the subgroup whose traits are not observed. Further, a combination of this modified F-test and Pearson's test is proposed by Fisher's combination of their P-values as a joint analysis. Because of the correlation of the two analyses, we propose to use a Gamma (scaled chi-squared) distribution to fit the asymptotic null distribution for the joint analysis. The proposed modified F-test and the joint analysis can also be applied to test single trait association (either binary or quantitative trait). Through simulations, we identify the situations under which the proposed tests are more powerful than the existing ones. Application to a real dataset of rheumatoid arthritis is presented. © 2012 Wiley Periodicals, Inc.

  6. Novel joint selection methods can reduce sample size for rheumatoid arthritis clinical trials with ultrasound endpoints.

    PubMed

    Allen, John C; Thumboo, Julian; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Tan, York Kiat

    2018-03-01

    To determine whether novel methods of selecting joints through (i) ultrasonography (individualized-ultrasound [IUS] method), or (ii) ultrasonography and clinical examination (individualized-composite-ultrasound [ICUS] method) translate into smaller rheumatoid arthritis (RA) clinical trial sample sizes when compared to existing methods utilizing predetermined joint sites for ultrasonography. Cohen's effect size (ES) was estimated (ES^) and a 95% CI (ES^L, ES^U) calculated on a mean change in 3-month total inflammatory score for each method. Corresponding 95% CIs [nL(ES^U), nU(ES^L)] were obtained on a post hoc sample size reflecting the uncertainty in ES^. Sample size calculations were based on a one-sample t-test as the patient numbers needed to provide 80% power at α = 0.05 to reject a null hypothesis H 0 : ES = 0 versus alternative hypotheses H 1 : ES = ES^, ES = ES^L and ES = ES^U. We aimed to provide point and interval estimates on projected sample sizes for future studies reflecting the uncertainty in our study ES^S. Twenty-four treated RA patients were followed up for 3 months. Utilizing the 12-joint approach and existing methods, the post hoc sample size (95% CI) was 22 (10-245). Corresponding sample sizes using ICUS and IUS were 11 (7-40) and 11 (6-38), respectively. Utilizing a seven-joint approach, the corresponding sample sizes using ICUS and IUS methods were nine (6-24) and 11 (6-35), respectively. Our pilot study suggests that sample size for RA clinical trials with ultrasound endpoints may be reduced using the novel methods, providing justification for larger studies to confirm these observations. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  7. Measurement of Clozapine, Norclozapine, and Amisulpride in Plasma and in Oral Fluid Obtained Using 2 Different Sampling Systems.

    PubMed

    Fisher, Danielle S; Beyer, Chad; van Schalkwyk, Gerrit; Seedat, Soraya; Flanagan, Robert J

    2017-04-01

    There is a poor correlation between total concentrations of proton-accepting compounds (most basic drugs) in unstimulated oral fluid and in plasma. The aim of this study was to compare clozapine, norclozapine, and amisulpride concentrations in plasma and in oral fluid collected using commercially available collection devices [Thermo Fisher Scientific Oral-Eze and Greiner Bio-One (GBO)]. Oral-Eze and GBO samples and plasma were collected in that order from patients prescribed clozapine. Analyte concentrations were measured by liquid chromatography-tandem mass spectrometry. There were 112 participants [96 men, aged (median, range) 47 (21-65) years and 16 women, aged 44 (21-65) years]: 74 participants provided 2 sets of samples and 7 provided 3 sets (overall 2 GBO samples not collected). Twenty-three patients were co-prescribed amisulpride, of whom 17 provided 2 sets of samples and 1 provided 3 sets. The median (range) oral fluid within the GBO samples was 52 (13%-86%). Nonadherence to clozapine was identified in all 3 samples in one instance. After correction for oral fluid content, analyte concentrations in the GBO and Oral-Eze samples were poorly correlated with plasma clozapine and norclozapine (R = 0.57-0.63) and plasma amisulpride (R = 0.65-0.72). Analyte concentrations in the 2 sets of oral fluid samples were likewise poorly correlated (R = 0.68-0.84). Mean (SD) plasma clozapine and norclozapine were 0.60 (0.46) and 0.25 (0.21) mg/L, respectively. Mean clozapine and norclozapine concentrations in the 2 sets of oral fluid samples were similar to those in plasma (0.9-1.8 times higher), that is, approximately 2- to 3-fold higher than those in unstimulated oral fluid. The mean (±SD) amisulpride concentrations (microgram per liter) in plasma (446 ± 297) and in the Oral-Eze samples (501 ± 461) were comparable and much higher than those in the GBO samples (233 ± 318). Oral fluid collected using either the GBO system or the Oral-Eze system cannot be used for

  8. The effect of intra-articular botulinum toxin A on substance P, prostaglandin E2, and tumor necrosis factor alpha in the canine osteoarthritic joint.

    PubMed

    Heikkilä, Helka M; Hielm-Björkman, Anna K; Innes, John F; Laitinen-Vapaavuori, Outi M

    2017-03-21

    Recently, intra-articular botulinum toxin A (IA BoNT A) has been shown to reduce joint pain in osteoarthritic dogs. Similar results have been reported in human patients with arthritis. However, the mechanism of the antinociceptive action of IA BoNT A is currently not known. The aim of this study was to explore this mechanism of action by investigating the effect of IA BoNT A on synovial fluid (SF) and serum substance P (SP), prostaglandin E 2 (PGE 2 ), and tumor necrosis factor alpha (TNF-α) in osteoarthritic dogs. Additionally, the aim was to compare SF SP and PGE 2 between osteoarthritic and non-osteoarthritic joints, and investigate associations between SP, PGE 2 , osteoarthritic pain, and the signalment of dogs. Thirty-five dogs with chronic naturally occurring osteoarthritis and 13 non-osteoarthritic control dogs were included in the study. Osteoarthritic dogs received either IA BoNT A (n = 19) or IA placebo (n = 16). Serum and SF samples were collected and osteoarthritic pain was evaluated before (baseline) and 2 and 8 weeks after treatment. Osteoarthritic pain was assessed with force platform, Helsinki Chronic Pain Index, and joint palpation. Synovial fluid samples were obtained from control dogs after euthanasia. The change from baseline in SP and PGE 2 concentration was compared between the IA BoNT A and placebo groups. The synovial fluid SP and PGE 2 concentration was compared between osteoarthritic and control joints. Associations between SP, PGE 2 , osteoarthritic pain, and the signalment of dogs were evaluated. There was no significant change from baseline in SP or PGE 2 after IA BoNT A. Synovial fluid PGE 2 was significantly higher in osteoarthritic compared to control joints. Synovial fluid PGE 2 correlated with osteoarthritic pain. No associations were found between SP or PGE 2 and the signalment of dogs. The concentration of TNF-α remained under the detection limit of the assay in all samples. The results suggest that the antinociceptive

  9. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  10. Tribological and Rheological Properties of a Synovial Fluid Model

    NASA Astrophysics Data System (ADS)

    Klossner, Rebecca; Liang, Jing; Krause, Wendy

    2010-03-01

    Hyaluronic acid (HA) and the plasma proteins, albumin and globulins, are the most abundant macromolecules in synovial fluid, the fluid that lubricates freely moving joints. In previous studies, bovine synovial fluid, a synovial fluid model (SFM) and albumin in phosphate buffered saline (PBS) were observed to be rheopectic---viscosity increases over time under constant shear. Additionally, steady shear experiments have a strong shear history dependence in protein-containing solutions, whereas samples of HA in PBS behaved as a ``typical'' polyelectrolyte. The observed rheopexy and shear history dependence are indicative of structure building in solution, which is most likely caused by protein aggregation. The tribology of the SFM was also investigated using nanoindenter-based scratch tests. The coefficient of frictions (μ) between the diamond nanoindenter tip and a polyethylene surface was measured in the presence of the SFM and solutions with varied protein and HA concentrations. The lowest μ is observed in the SFM, which most closely mimics a healthy joint. Finally, an anti-inflammatory drug, hydroxychloroquine, was shown to inhibit protein interactions in the SFM in rheological studies, and thus the tribological response was examined. We hypothesize that the rheopectic behavior is important in lubrication regimes and therefore, the rheological and tribological properties of these solutions will be correlated.

  11. Fluid intelligence and psychiatric disorders in a population representative sample of US adolescents

    PubMed Central

    Keyes, Katherine M.; Platt, Jonathan; Kaufman, Alan S.; McLaughlin, Katie A.

    2017-01-01

    Importance Despite long-standing interest in the association of psychiatric disorders with intelligence, few population-based studies of psychiatric disorders have assessed intelligence. Objectives To investigate the association of fluid intelligence with past-year and lifetime psychiatric disorders, disorder age-of-onset, and disorder severity in a nationally-representative sample of U.S. adolescents. Design Dual-frame national sample of adolescents ascertained from schools and households from the National Comorbidity Survey Replication-Adolescent Supplement, collected 2001–2004. Setting Face-to-face household interviews with adolescents and questionnaires from parents. Participants The sample included 10,073 adolescents with valid data on fluid intelligence. Exposures DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview, and included a broad range of fear, distress, behavior, substance use and other disorders. Disorder severity was measured with the Sheehan Disability Scale. Main Outcomes Fluid intelligence quotient (IQ) measured with Kaufman Brief Intelligence Test, normed within the sample by six-month age groups. Results Lower mean IQ was observed among adolescents with past-year bipolar disorder (predicted Mean [M]=94.2, p<0.01), attention-deficit/hyperactivity disorder (M=96.3, p<0.01), oppositional defiant disorder (M=97.3, p<0.01), conduct disorder (M=97.1, p=0.02) substance disorders (M=96.5–97.6, p=0.02 to <0.01) and specific phobia (M=97.1, p<0.01) after adjustment for a wide range of potential confounders. Intelligence was not associated with post-traumatic stress disorder, eating disorders, and anxiety disorders other than specific phobia, and was positively associated with major depression. Associations of fluid intelligence with lifetime disorders that had remitted were attenuated compared to past-year disorders, with the exception of separation anxiety disorder. Across disorders

  12. Raman spectroscopy of synovial fluid as a tool for diagnosing osteoarthritis

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Raaii, Farhang; Jacobson, Jon A.; Miller, Bruce S.; Urquhart, Andrew G.; Roessler, Blake J.; Morris, Michael D.

    2009-05-01

    For many years, viscosity has been the primary method used by researchers in rheumatology to assess the physiochemical properties of synovial fluid in both normal and osteoarthritic patients. However, progress has been limited by the lack of methods that provide multiple layers of information, use small sample volumes, and are rapid. Raman spectroscopy was used to assess the biochemical composition of synovial fluid collected from 40 patients with clinical evidence of knee osteoarthritis (OA) at the time of elective surgical treatment. Severity of knee osteoarthritis was assessed by a radiologist using Kellgren/Lawrence (K/L) scores from knee joint x rays, while light microscopy and Raman spectroscopy were used to examine synovial fluid (SF) aspirates (2 to 10 μL), deposited on fused silica slides. We show that Raman bands used to describe protein secondary structure and content can be used to detect changes in synovial fluid from osteoarthritic patients. Several Raman band intensity ratios increased significantly in spectra collected from synovial fluid in patients with radiological evidence of moderate-to-severe osteoarthritis damage. These ratios can be used to provide a ``yes/no'' damage assessment. These studies provide evidence that Raman spectroscopy would be a suitable candidate in the evaluation of joint damage in knee osteoarthritis patients.

  13. Total nucleated cell and leukocyte differential counts in canine pleural and peritoneal fluid and equine synovial fluid samples: comparison of automated and manual methods.

    PubMed

    Brudvig, Jean M; Swenson, Cheryl L

    2015-12-01

    Rapid and precise measurement of total and differential nucleated cell counts is a crucial diagnostic component of cavitary and synovial fluid analyses. The objectives of this study included (1) evaluation of reliability and precision of canine and equine fluid total nucleated cell count (TNCC) determined by the benchtop Abaxis VetScan HM5, in comparison with the automated reference instruments ADVIA 120 and the scil Vet abc, respectively, and (2) comparison of automated with manual canine differential nucleated cell counts. The TNCC and differential counts in canine pleural and peritoneal, and equine synovial fluids were determined on the Abaxis VetScan HM5 and compared with the ADVIA 120 and Vet abc analyzer, respectively. Statistical analyses included correlation, least squares fit linear regression, Passing-Bablok regression, and Bland-Altman difference plots. In addition, precision of the total cell count generated by the VetScan HM5 was determined. Agreement was excellent without significant constant or proportional bias for canine cavitary fluid TNCC. Automated and manual differential counts had R(2)  < .5 for individual cell types (least squares fit linear regression). Equine synovial fluid TNCC agreed but with some bias due to the VetScan HM5 overestimating TNCC compared to the Vet abc. Intra-assay precision of the VetScan HM5 in 3 fluid samples was 2-31%. The Abaxis VetScan HM5 provided rapid, reliable TNCC for canine and equine fluid samples. The differential nucleated cell count should be verified microscopically as counts from the VetScan HM5 and also from the ADVIA 120 were often incorrect in canine fluid samples. © 2015 American Society for Veterinary Clinical Pathology.

  14. Ureaplasma parvum prosthetic joint infection detected by PCR.

    PubMed

    Farrell, John J; Larson, Joshua A; Akeson, Jeffrey W; Lowery, Kristin S; Rounds, Megan A; Sampath, Rangarajan; Bonomo, Robert A; Patel, Robin

    2014-06-01

    We describe the first reported case of Ureaplasma parvum prosthetic joint infection (PJI) detected by PCR. Ureaplasma species do not possess a cell wall and are usually associated with colonization and infection of mucosal surfaces (not prosthetic material). U. parvum is a relatively new species name for certain serovars of Ureaplasma urealyticum, and PCR is useful for species determination. Our patient presented with late infection of his right total knee arthroplasty. Intraoperative fluid and tissue cultures and pre- and postoperative synovial fluid cultures were all negative. To discern the pathogen, we employed PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS). Our patient's failure to respond to empirical antimicrobial treatment and our previous experience with PCR/ESI-MS in culture-negative cases of infection prompted us to use this approach over other diagnostic modalities. PCR/ESI-MS detected U. parvum in all samples. U. parvum-specific PCR testing was performed on all synovial fluid samples to confirm the U. parvum detection. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  15. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    PubMed

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Emergence of Complex Conditional Discriminations by Joint Control of Compound Samples

    ERIC Educational Resources Information Center

    Alonso-Alvarez, Benigno; Perez-Gonzalez, Luis Antonio

    2006-01-01

    The goal of the present study was to explore the emergence of verbal behavior resulting from the joint control of two antecedent stimuli that are presented together for the first time. Conditional discriminations were used for teaching and for probing. Four stimuli PI, P2, 0 1 , and 02 were samples and four stimuli Al, A2, BI, and B2 were the…

  17. Randomised prospective study compares efficacy of five different stomach tubes for rumen fluid sampling in dairy cows.

    PubMed

    Steiner, S; Neidl, A; Linhart, N; Tichy, A; Gasteiner, J; Gallob, K; Baumgartner, W; Wittek, T

    2015-01-10

    The objective of the study was to compare the performance of five types of stomach tubes for rumen fluid sampling. Rumen fluid was sampled in rumen fistulated cows assigned to a 5×5 Latin square study design. The pH values of samples taken by stomach tubes and via fistulas were measured; the results were compared with indwelling sensor measurements. The practicability of the stomach tubes for regular use was tested in the field. Rumen fluid samples were obtained rapidly. Volumes for transfaunation could be obtained. The pH-values of samples taken with the four out of the five tubes (Dirksen, Geishauser, tube 4 and a simple water hose used with a gag) did not show significant differences to samples taken via rumen fistulas. Mean differences ranged between -0.02 and +0.09. Samples taken with tube 4 and the water hose showed also no significant differences to pH-sensor measurements. This study demonstrates that stomach tubes are suitable for rumen fluid sampling. Tube 4 seems to be the best probe for work in the field. It was well tolerated by the animals, saliva contamination is negligible. We, therefore, conclude that the evaluation of rumen acid base status in the field is possible. British Veterinary Association.

  18. Validation and Comparison of Two Sampling Methods to Assess Dermal Exposure to Drilling Fluids and Crude Oil

    PubMed Central

    Galea, Karen S.; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez

    2014-01-01

    Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs’ trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods’ comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. PMID:24598941

  19. Serum and synovial fluid C-reactive protein level variations in dogs with degenerative joint disease and their relationships with physiological parameters.

    PubMed

    Boal, S; Miguel Carreira, L

    2015-09-01

    Degenerative joint disease (DJD) is a progressive, chronic joint disease with an inflammatory component promoting an acute phase protein (APP) response. C-reactive protein (CRP) is one of the most important APPs, used as an inflammation marker in human, but not veterinary medicine. The study was developed in a sample of 48 dogs (n = 48) with DJD and aimed to: 1) identify and quantify the synovial fluid CRP (SFCRP) in these specimens using a validated ELISA test for serum CRP (SCRP) detection and quantification; and 2) to study the possible relationship between SCRP and SFCRP levels variations in DJD patients evaluating the influence of some physical parameters such as gender, body weight, pain level, DJD grade, and the physical activity (PA) of the patients. Statistical analysis considered the results significant for p values <0.05. Our study showed that it is possible to detect and quantify SFCRP levels in DJD patients using a previously validated canine SCRP ELISA test, allowing us to point out a preliminary reference value for SFCRP in patients with DJD. Although, individuals with DJD presents SCRP values within the normal reference range and the SFCRP levels were always lower. Obesity, pain, and the DJD grade presented by the patients are conditions which seem to influence the SCRP levels but not the SFCRP.

  20. Comparison of 2 fluid ingress/egress systems for canine stifle arthroscopy using computed tomography.

    PubMed

    Warnock, Jennifer J; Nemanic, Sarah; O'Donnell, Matthew D; Wiest, Jason E

    2014-11-01

    To evaluate volume of extra-articular fluid egress and complications associated with 2 fluid ingress/egress techniques for stifle arthroscopy. Ex vivo study. Canine cadavers (n = 14). Four cadavers (8 stifles) were used to validate 3D computed tomographic (CT) methods to quantify stifle joint intra- and extra-articular volumes of iodinated contrast medium. Ten canine cadavers (20 stifles) had preoperative CT, followed by stifle arthroscopy using a 10% solution of iodinated contrast enhanced ingress fluid delivered by pressure bag (2PB) or by arthroscopic peristaltic pump (3FP). All 3FP limbs had an additional fluid egress portal placed by cannula and obturator. Arthroscopy was limited to 20 minutes/joint. The volume of the contrast medium egress into the soft tissues was measured on postoperative 3D CT reconstructed images. Mean percentage of total ingress fluids administered that remained in the joint and extra-articular tissues postoperatively was 8.8 ± 1.2% in 3FP and 33.2 ± 8% in 2PB (P = .014). Two 3FP joints had 4-5 mm egress obturator tracks on the proximal medial trochlear ridge. Two 2PB joints had severe joint collapse from extracapsular fluid precluding further examination. Intermittent visual blurring by joint fluid mixing or fat pad fragmentation/dissolution was noted in 2PB joints. A superior technique was not identified: 2PB had greater egress fluid tissue accumulation, whereas 3FP had better viewing of intra-articular structures with less tissue egress fluid accumulation; however, cartilage damage was induced with the egress obturator. © Copyright 2014 by The American College of Veterinary Surgeons.

  1. Trans-dimensional joint inversion of seabed scattering and reflection data.

    PubMed

    Steininger, Gavin; Dettmer, Jan; Dosso, Stan E; Holland, Charles W

    2013-03-01

    This paper examines joint inversion of acoustic scattering and reflection data to resolve seabed interface roughness parameters (spectral strength, exponent, and cutoff) and geoacoustic profiles. Trans-dimensional (trans-D) Bayesian sampling is applied with both the number of sediment layers and the order (zeroth or first) of auto-regressive parameters in the error model treated as unknowns. A prior distribution that allows fluid sediment layers over an elastic basement in a trans-D inversion is derived and implemented. Three cases are considered: Scattering-only inversion, joint scattering and reflection inversion, and joint inversion with the trans-D auto-regressive error model. Including reflection data improves the resolution of scattering and geoacoustic parameters. The trans-D auto-regressive model further improves scattering resolution and correctly differentiates between strongly and weakly correlated residual errors.

  2. Dynamic properties of human incudostapedial joint-Experimental measurement and finite element modeling.

    PubMed

    Jiang, Shangyuan; Gan, Rong Z

    2018-04-01

    The incudostapedial joint (ISJ) is a synovial joint connecting the incus and stapes in the middle ear. Mechanical properties of the ISJ directly affect sound transmission from the tympanic membrane to the cochlea. However, how ISJ properties change with frequency has not been investigated. In this paper, we report the dynamic properties of the human ISJ measured in eight samples using a dynamic mechanical analyzer (DMA) for frequencies from 1 to 80 Hz at three temperatures of 5, 25 and 37 °C. The frequency-temperature superposition (FTS) principle was used to extrapolate the results to 8 kHz. The complex modulus of ISJ was measured with a mean storage modulus of 1.14 MPa at 1 Hz that increased to 3.01 MPa at 8 kHz, and a loss modulus that increased from 0.07 to 0.47 MPa. A 3-dimensional finite element (FE) model consisting of the articular cartilage, joint capsule and synovial fluid was then constructed to derive mechanical properties of ISJ components by matching the model results to experimental data. Modeling results showed that mechanical properties of the joint capsule and synovial fluid affected the dynamic behavior of the joint. This study contributes to a better understanding of the structure-function relationship of the ISJ for sound transmission. Copyright © 2018. Published by Elsevier Ltd.

  3. Statistical inferences with jointly type-II censored samples from two Pareto distributions

    NASA Astrophysics Data System (ADS)

    Abu-Zinadah, Hanaa H.

    2017-08-01

    In the several fields of industries the product comes from more than one production line, which is required to work the comparative life tests. This problem requires sampling of the different production lines, then the joint censoring scheme is appeared. In this article we consider the life time Pareto distribution with jointly type-II censoring scheme. The maximum likelihood estimators (MLE) and the corresponding approximate confidence intervals as well as the bootstrap confidence intervals of the model parameters are obtained. Also Bayesian point and credible intervals of the model parameters are presented. The life time data set is analyzed for illustrative purposes. Monte Carlo results from simulation studies are presented to assess the performance of our proposed method.

  4. Validation and comparison of two sampling methods to assess dermal exposure to drilling fluids and crude oil.

    PubMed

    Galea, Karen S; McGonagle, Carolyn; Sleeuwenhoek, Anne; Todd, David; Jiménez, Araceli Sánchez

    2014-06-01

    Dermal exposure to drilling fluids and crude oil is an exposure route of concern. However, there have been no published studies describing sampling methods or reporting dermal exposure measurements. We describe a study that aimed to evaluate a wipe sampling method to assess dermal exposure to an oil-based drilling fluid and crude oil, as well as to investigate the feasibility of using an interception cotton glove sampler for exposure on the hands/wrists. A direct comparison of the wipe and interception methods was also completed using pigs' trotters as a surrogate for human skin and a direct surface contact exposure scenario. Overall, acceptable recovery and sampling efficiencies were reported for both methods, and both methods had satisfactory storage stability at 1 and 7 days, although there appeared to be some loss over 14 days. The methods' comparison study revealed significantly higher removal of both fluids from the metal surface with the glove samples compared with the wipe samples (on average 2.5 times higher). Both evaluated sampling methods were found to be suitable for assessing dermal exposure to oil-based drilling fluids and crude oil; however, the comparison study clearly illustrates that glove samplers may overestimate the amount of fluid transferred to the skin. Further comparison of the two dermal sampling methods using additional exposure situations such as immersion or deposition, as well as a field evaluation, is warranted to confirm their appropriateness and suitability in the working environment. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Size selectivity of hyaluronan molecular sieving by extracellular matrix in rabbit synovial joints

    PubMed Central

    Sabaratnam, S; Arunan, V; Coleman, PJ; Mason, RM; Levick, JR

    2005-01-01

    In joint fluid the polymer hyaluronan (HA) confers viscous lubrication and greatly attenuates trans-synovial fluid loss (outflow buffering). Outflow buffering arises from the molecular sieving (reflection) and concentration polarization of HA at the synovial membrane surface. Outflow buffering declines if HA chain length is reduced, as in arthritis, and this has been attributed to reduced HA reflection. This was tested directly in the present study. Infused solutions of HA of ∼2200 kDa (HA2000, 0.2 mg ml−1) or ∼500 kDa (HA500, 0.2 mg ml−1) or ∼140 kDa (HA140, 0.2–4.0 mg ml−1) were filtered across the synovial lining of the knee joint cavity of anaesthetized rabbits at a constant rate, along with a freely permeating reference solute, 20 kDa fluorescein–dextran (FD20). After a priming period the femoral lymph was sampled over 3 h. Mixed intra-articular (i.a.) fluid and subsynovial fluid were sampled at the end. Fluids were analysed by gel exclusion chromatography. The trans-synovial concentration profile was found to depend on polymer size. The i.a. concentration of HA2000 increased substantially relative to infusate and the subsynovial and lymph concentrations fell substantially. For HA500 and HA140 the trans-synovial concentration gradients were less pronounced, and absent for FD. The reflected fractions for HA2000, HA500 and HA140 across the cavity-to-lymph barrier were 0.65 ± 0.05 (n = 10), 0.43 ± 0.09 (n = 3) and 0.19 ± 0.05 (n = 7), respectively, at matched filtration rates (P < 0.0001, analysis of variance). Reflected fractions calculated from HA i.a. accumulation or subsynovial dilution showed the same trend. The results demonstrate size-selective molecular sieving by the synovial extracellular matrix, equivalent to steric exclusion from cylindrical pores of radius 33–59 nm. The findings underpin the concentration polarization-outflow buffering theory and indicate that reduced HA chain length in arthritis exacerbates lubricant loss from a

  6. Molecular Diagnosis of Orthopedic-Device-Related Infection Directly from Sonication Fluid by Metagenomic Sequencing

    PubMed Central

    Sanderson, Nicholas D.; Atkins, Bridget L.; Brent, Andrew J.; Cole, Kevin; Foster, Dona; McNally, Martin A.; Oakley, Sarah; Peto, Leon; Taylor, Adrian; Peto, Tim E. A.; Crook, Derrick W.; Eyre, David W.

    2017-01-01

    ABSTRACT Culture of multiple periprosthetic tissue samples is the current gold standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through culture of sonication fluid from explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of total DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI. We compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 derivation samples, we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and confirmed our findings in 47 independent validation samples. Compared to results from sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69 (88%; 95% confidence interval [CI], 77 to 94%; for derivation samples 35/38 [92%; 95% CI, 79 to 98%]; for validation samples, 26/31 [84%; 95% CI, 66 to 95%]), and genus-level sensitivity was 64/69 (93%; 95% CI, 84 to 98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97 (88%; 95% CI, 79 to 93%; for derivation samples, 43/50 [86%; 95% CI, 73 to 94%]; for validation samples, 42/47 [89%; 95% CI, 77 to 96%]). High levels of human DNA contamination were seen despite the use of laboratory methods to remove it. Rigorous laboratory good practice was required to minimize bacterial DNA contamination. We demonstrate that metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings

  7. Antioxidant capacity of synovial fluid in the temporomandibular joint correlated with radiological morphology of temporomandibular disorders.

    PubMed

    Ishimaru, Kyoko; Ohba, Seigo; Yoshimura, Hitoshi; Matsuda, Shinpei; Ishimaru, Jun-Ichi; Sano, Kazuo

    2015-02-01

    We investigated the correlation between the antioxidant capacity of synovial fluid and radiological findings of intra-articular structures in patients with disorders of the temporomandibular joint (TMJ). We recruited 21 patients (9 men and 12 women, aged 18-84 years of age) with such disorders, excluding myofascial pain and dysfunction syndrome, or other muscular disorders. The clinical variables recorded included age, sex, interincisal distance, and visual analogue pain scores (VAS). Radiological findings were obtained from diagnostic arthrogram and cone-beam computed tomography (CT). The antioxidant capacity of the synovial fluid was measured by chemiluminescence. Eleven patients were radiologically diagnosed with closed lock, and the remaining 10 with no closed lock. An anchored intra-articular disc was most often seen on cone-beam CT (n=19) followed by perforated disc (n=7), osteoarthrosis (n=7), and anterior disc displacement without reduction (n=5). Although there were no significant differences between antioxidant capacity and age, sex, VAS, or any findings on cone-beam CT, antioxidant capacity was significantly decreased in the patients with closed lock compared with those who did not have closed lock (p=0.02). The results suggest an association between the oxidative stress of the synovial fluid and closed-lock in disorders of the TMJ. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Performance of Xpert MTB/RIF on Ascitic Fluid Samples for Detection of Abdominal Tuberculosis.

    PubMed

    Rufai, Syed Beenish; Singh, Sarman; Singh, Amit; Kumar, Parveen; Singh, Jitendra; Vishal, Anand

    2017-01-01

    Diagnosis of abdominal tuberculosis (TB) from ascitic fluid samples using routinely available diagnostic methods is challenging due to its paucibacillary nature. Although performance of Xpert MTB/RIF assay has been evaluated extensively on pulmonary samples, its performance on extrapulmonary samples is still under evaluation. The objective of this study was to find out the performance of Xpert MTB/RIF on ascitic fluid samples obtained from suspected cases of abdominal TB. Performance was compared with Mycobacterium growth indicator tube-960 (MGIT-960) culture and in-house multiplex polymerase chain reaction (PCR). The latter detects and differentiates Mycobacterium tuberculosis and nontuberculous mycobacteria simultaneously. Sixty-seven patients suspected of probable/possible abdominal TB were included in this observational, prospective study. All samples were tested by Ziehl-Neelsen staining, MGIT-960 culture, in-house multiplex PCR, and Xpert MTB/RIF assay. All 67 samples were smear negative. Seventeen (25.4%) were MGIT-960 culture positive while 12 (17.9%) were detected positive by the Xpert MTB/RIF assay and 9 (13.4%) by in-house multiplex PCR. Sensitivity and specificity of the Xpert MTB/RIF assay compared with the MGIT-960 culture were 70.6% (95%, confidence interval [CI]: 44.1-89.7) and 100% (95%, CI: 92.8-100) and that of in-house multiplex PCR were 52.9% (95%, CI: 30.9-73.8) and 100% (95%, CI: 92.8-100), respectively. Diagnostic yield of Xpert MTB/RIF assay on ascitic fluid samples was lower than MGIT-960 culture. We thus emphasize on the need for urgent discovery of new biomarkers for paucibacillary TB.

  9. Joint properties of a tool machining process to guarantee fluid-proof abilities

    NASA Astrophysics Data System (ADS)

    Bataille, C.; Deltombe, R.; Jourani, A.; Bigerelle, M.

    2017-12-01

    This study addressed the impact of rod surface topography in contact with reciprocating seals. Rods were tooled with and without centreless grinding. All rods tooled with centreless grinding were fluid-proof, in contrast to rods tooled without centreless grinding that either had leaks or were fluid-proof. A method was developed to analyse the machining signature, and the software Mesrug™ was used in order to discriminate roughness parameters that can be used to characterize the sealing functionality. According to this surface roughness analysis, a fluid-proof rod tooled without centreless grinding presents aperiodic large plateaus, and the relevant roughness parameter for characterizing the sealing functionality is the density of summits S DS. Increasing the density of summits counteracts leakage, which may be because motif decomposition integrates three topographical components: circularity (perpendicular long-wave roughness), longitudinal waviness, and roughness thanks to the Wolf pruning algorithm. A 3D analytical contact model was applied to analyse the contact area of each type of sample with the seal surface. This model provides a leakage probability, and the results were consistent with the interpretation of the topographical analysis.

  10. Porcine reproductive and respiratory syndrome virus (PRRSV) surveillance using pre-weaning oral fluid samples detects circulation of wild-type PRRSV.

    PubMed

    Kittawornrat, Apisit; Panyasing, Yaowalak; Goodell, Christa; Wang, Chong; Gauger, Phillip; Harmon, Karen; Rauh, Rolf; Desfresne, Luc; Levis, Ian; Zimmerman, Jeffrey

    2014-01-31

    Oral fluid samples collected from litters of piglets (n=600) one day prior to weaning were evaluated as a method to surveil for porcine reproductive and respiratory syndrome virus (PRRSV) infections in four sow herds of approximately 12,500 sow each. Serum samples from the litters' dam (n=600) were included for comparison. All four herds were endemically infected with PRRSV and all sows had been vaccinated ≥ 2 times with PRRSV modified-live virus vaccines. After all specimens had been collected, samples were randomized and assayed by PRRSV real-time reverse transcription polymerase chain reaction (RT-qPCR) and four PRRSV antibody ELISA assays (IgM, IgA, IgG, and Commercial Kit). All sow serum samples were negative by PRRSV RT-qPCR, but 9 of 600 oral fluid samples tested positive at two laboratories. Open reading frame 5 (ORF5) sequencing of 2 of the 9 positive oral fluid samples identified wild-type viruses as the source of the infection. A comparison of antibody responses in RT-qPCR positive vs. negative oral fluid samples showed significantly higher IgG S/P ratios in RT-qPCR-positive oral fluid samples (mean S/P 3.46 vs. 2.36; p=0.02). Likewise, sow serum samples from RT-qPCR-positive litter oral fluid samples showed significantly higher serum IgG (mean S/P 1.73 vs. 0.98; p<0.001) and Commercial Kit (mean S/P 1.97 vs. 0.98; p<0.001) S/P ratios. Overall, the study showed that pre-weaning litter oral fluid samples could provide an efficient and sensitive approach to surveil for PRRSV in infected, vaccinated, or presumed-negative pig breeding herds. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Occurrence of viral DNA in paired samples of corneal rim and cornea preservation fluid.

    PubMed

    Broniek, G; Langwińska-Wośko, E; Sybilska, M; Szaflik, J P; Przybylski, M; Wróblewska, M

    2017-04-01

    Corneal transplants have one of the highest success rates among all transplantological procedures. Corneas intended for transplantation are stored in a preservation fluid, which is then tested for bacterial and fungal infections. Among all analyses of infectious complications following corneal transplants, infections caused by bacteria or fungi are the most prominent. Surprisingly, however, apart from a few publications, there is a lack of data regarding the occurrence of viruses in donor corneas and the risk of transmitting these to their recipients. The intention of this research was therefore to determine the frequency with which human herpesvirus 1 (HHV-1), human herpesvirus 2 (HHV-2), and human adenovirus (HAdV) occur in transplanted corneal tissue, as well as in samples of preservation fluid. The study comprised 57 paired samples, with each pair consisting of a fragment of the corneal tissue remaining after its trepanation for transplantation surgery and a sample of corneal preservation fluid. Sample pairs were all tested for the presence of the DNA of three viruses (HHV-1, HHV-2, and HAdV) using real time PCR technique. Viral DNA was found in three of the tested corneas-HHV-1 DNA in one paired sample (1.8%) and adenovirus DNA in two single samples (3.5%). We postulate that virological testing of corneas for transplantation should be considered, particularly in the case of donors with increased risk factors for herpesvirus and adenovirus reactivation. J. Med. Virol. 89:732-736, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. No bacterial growth found in spiked intravenous fluids over an 8-hour period.

    PubMed

    Haas, Richard E; Beitz, Edwin; Reed, Amy; Burtnett, Howard; Lowe, Jason; Crist, Arthur E; Stierer, Kevin A; Birenberg, Allan M

    2017-04-01

    Protocol changes prompted by the Joint Commission mandating intravenous (IV) fluid bags to be used within 1 hour of spiking because of possible bacterial contamination have sparked clinical and economic concerns. This study investigated the degree of bacterial growth in which samples were obtained from spiked IV fluid bags at the time of spiking and 1, 2, 4, and 8 hours after spiking. No bacterial growth occurred in any of the 80 bags of Lactated Ringer's (LR) IV solutions sampled. This study demonstrated that LR IV bags do not support any bacterial growth for up to 8 hours after spiking. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Inflammation is more distinct in temporomandibular joint osteoarthritis compared to the knee joint.

    PubMed

    Vos, Lukas M; Kuijer, Roel; Huddleston Slater, James J R; Bulstra, Sjoerd K; Stegenga, Boudewijn

    2014-01-01

    Most of the current understanding of articular cartilage maintenance and degradation is derived from large load-bearing synovial joints, in particular the knee joint. The aim of this study was to identify valuable degradation markers for cartilage degradation in the temporomandibular joint (TMJ) by comparing the relative concentrations of carboxyterminal telopeptides of collagen types I and II (CTX-I and CTX-II), cartilage oligomeric matrix protein (COMP), and prostaglandin E2 (PGE2) in synovial fluid (SF) of TMJ and knee joints with cartilage degradation. In this cross-sectional comparative study, participants were recruited from the University Medical Center Groningen, The Netherlands. Patients with TMJ osteoarthritis were compared with patients with knee osteoarthritis. The outcome variables were the relative SF concentrations of CTX-I, CTX-II, COMP, and PGE2. An independent samples Mann-Whitney U test was used to compare the relative concentrations. Thirty consecutive patients (9 male, 21 female; mean age, 40.1 yr; standard deviation, 15.3 yr) with TMJ osteoarthritis and 31 consecutive patients (20 male, 11 female; mean age, 37.4 yr; standard deviation, 13.7 yr) who were scheduled for arthroscopy of the knee joint participated in this study. Significant differences were found between relative concentrations of COMP (P = .000) and PGE2 (P = .005), and no significant differences were found between relative concentrations of CTX-I (P = .720) and CTX-II (P = .242). Relative SF concentrations of COMP and PGE2 showed significant differences between the TMJ and the knee joint, suggesting that there are differences in pathophysiology and that the inflammatory component may be more distinct in the TMJ. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Mud Volcanoes in the Martian Lowlands: Potential Windows to Fluid-Rich Samples from Depth

    NASA Technical Reports Server (NTRS)

    Oehler, Dorothy Z.; Allen, Carlton C.

    2009-01-01

    The regional setting of the Chryse-Acidalia area augurs well for a fluid-rich subsurface, accumulation of diverse rock types reflecting the wide catchment area, astrobiological prospectivity, and mud volcanism. This latter provides a mechanism for transporting samples from relatively great depth to the surface. Since mud volcanoes are not associated with extreme heat or shock pressures, materials they transport to the surface are likely to be relatively unaltered; thus such materials could contain interpretable remnants of potential martian life (e.g., organic chemical biomarkers, mineral biosignatures, or structural remains) as well as unmetamorphosed rock samples. None of the previous landings on Mars was located in an area with features identified as potential mud volcanoes (Fig. 3), but some of these features may offer targets for future missions aimed at sampling deep fluid-rich strata with potential habitable zones.

  15. Signaling networks in joint development

    PubMed Central

    Salva, Joanna E.; Merrill, Amy E.

    2016-01-01

    Here we review studies identifying regulatory networks responsible for synovial, cartilaginous, and fibrous joint development. Synovial joints, characterized by the fluid-filled synovial space between the bones, are found in high-mobility regions and are the most common type of joint. Cartilaginous joints unite adjacent bones through either a hyaline cartilage or fibrocartilage intermediate. Fibrous joints, which include the cranial sutures, form a direct union between bones through fibrous connective tissue. We describe how the distinct morphologic and histogenic characteristics of these joint classes are established during embryonic development. Collectively, these studies reveal that despite the heterogeneity of joint strength and mobility, joint development throughout the skeleton utilizes common signaling networks via long-range morphogen gradients and direct cell-cell contact. This suggests that different joint types represent specialized variants of homologous developmental modules. Identifying the unifying aspects of the signaling networks between joint classes allows a more complete understanding of the signaling code for joint formation, which is critical to improving strategies for joint regeneration and repair. PMID:27859991

  16. Impact of mechanical heterogeneity on joint density in a welded ignimbrite

    NASA Astrophysics Data System (ADS)

    Soden, A. M.; Lunn, R. J.; Shipton, Z. K.

    2016-08-01

    Joints are conduits for groundwater, hydrocarbons and hydrothermal fluids. Robust fluid flow models rely on accurate characterisation of joint networks, in particular joint density. It is generally assumed that the predominant factor controlling joint density in layered stratigraphy is the thickness of the mechanical layer where the joints occur. Mechanical heterogeneity within the layer is considered a lesser influence on joint formation. We analysed the frequency and distribution of joints within a single 12-m thick ignimbrite layer to identify the controls on joint geometry and distribution. The observed joint distribution is not related to the thickness of the ignimbrite layer. Rather, joint initiation, propagation and termination are controlled by the shape, spatial distribution and mechanical properties of fiamme, which are present within the ignimbrite. The observations and analysis presented here demonstrate that models of joint distribution, particularly in thicker layers, that do not fully account for mechanical heterogeneity are likely to underestimate joint density, the spatial variability of joint distribution and the complex joint geometries that result. Consequently, we recommend that characterisation of a layer's compositional and material properties improves predictions of subsurface joint density in rock layers that are mechanically heterogeneous.

  17. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  18. Fluid transport container

    DOEpatents

    DeRoos, Bradley G.; Downing, Jr., John P.; Neal, Michael P.

    1995-01-01

    An improved fluid container for the transport, collection, and dispensing of a sample fluid that maintains the fluid integrity relative to the conditions of the location at which it is taken. More specifically, the invention is a fluid sample transport container that utilizes a fitment for both penetrating and sealing a storage container under controlled conditions. Additionally, the invention allows for the periodic withdrawal of portions of the sample fluid without contamination or intermixing from the environment surrounding the sample container.

  19. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery.

    PubMed

    Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li

    2018-08-01

    Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.

  20. Biofluid lubrication for artificial joints

    NASA Astrophysics Data System (ADS)

    Pendleton, Alice Mae

    This research investigated biofluid lubrication related to artificial joints using tribological and rheological approaches. Biofluids studied here represent two categories of fluids, base fluids and nanostructured biofluids. Base fluids were studied through comparison of synthetic fluids (simulated body fluid and hyaluronic acid) as well as natural biofluids (from dogs, horses, and humans) in terms of viscosity and fluid shear stress. The nano-structured biofluids were formed using molecules having well-defined shapes. Understanding nano-structured biofluids leads to new ways of design and synthesis of biofluids that are beneficial for artificial joint performance. Experimental approaches were utilized in the present research. This includes basic analysis of biofluids' property, such as viscosity, fluid shear stress, and shear rate using rheological experiments. Tribological investigation and surface characterization were conducted in order to understand effects of molecular and nanostructures on fluid lubrication. Workpiece surface structure and wear mechanisms were investigated using a scanning electron microscope and a transmission electron microscope. The surface topography was examined using a profilometer. The results demonstrated that with the adding of solid additives, such as crown ether or fullerene acted as rough as the other solids in the 3-body wear systems. In addition, the fullerene supplied low friction and low wear, which designates the lubrication purpose of this particular particle system. This dissertation is constructed of six chapters. The first chapter is an introduction to body fluids, as mentioned earlier. After Chapter II, it examines the motivation and approach of the present research, Chapter III discusses the experimental approaches, including materials, experimental setup, and conditions. In Chapter IV, lubrication properties of various fluids are discussed. The tribological properties and performance nanostructured biofluids are

  1. Osteoarthritis screening using Raman spectroscopy of dried human synovial fluid drops

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Karen A.; Mandair, Gurjit S.; Esmonde-White, Francis W. L.; Raaii, Farhang; Roessler, Blake J.; Morris, Michael D.

    2009-02-01

    We describe the use of Raman spectroscopy to investigate synovial fluid drops deposited onto fused silica microscope slides. This spectral information can be used to identify chemical changes in synovial fluid associated with osteoarthritis (OA) damage to knee joints. The chemical composition of synovial fluid is predominately proteins (enzymes, cytokines, or collagen fragments), glycosaminoglycans, and a mixture of minor components such as inorganic phosphate crystals. During osteoarthritis, the chemical, viscoelastic and biological properties of synovial fluid are altered. A pilot study was conducted to determine if Raman spectra of synovial fluid correlated with radiological scoring of knee joint damage. After informed consent, synovial fluid was drawn and x-rays were collected from the knee joints of 40 patients. Raman spectra and microscope images were obtained from the dried synovial fluid drops using a Raman microprobe and indicate a coarse separation of synovial fluid components. Individual protein signatures could not be identified; Raman spectra were useful as a general marker of overall protein content and secondary structure. Band intensity ratios used to describe protein and glycosaminoglycan structure were used in synovial fluid spectra. Band intensity ratios of Raman spectra indicate that there is less ordered protein secondary structure in synovial fluid from the damage group. Combination of drop deposition with Raman spectroscopy is a powerful approach to examining synovial fluid for the purposes of assessing osteoarthritis damage.

  2. Diagnosing periprosthetic joint infection: has the era of the biomarker arrived?

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-11-01

    The diagnosis of periprosthetic joint infection (PJI) remains a serious clinical challenge. There is a pressing need for improved diagnostic testing methods; biomarkers offer one potentially promising approach. We evaluated the diagnostic characteristics of 16 promising synovial fluid biomarkers for the diagnosis of PJI. Synovial fluid was collected from 95 patients meeting the inclusion criteria of this prospective diagnostic study. All patients were being evaluated for a revision hip or knee arthroplasty, including patients with systemic inflammatory disease and those already receiving antibiotic treatment. The Musculoskeletal Infection Society (MSIS) definition was used to classify 29 PJIs and 66 aseptic joints. Synovial fluid samples were tested by immunoassay for 16 biomarkers optimized for use in synovial fluid. Sensitivity, specificity, and receiver operating characteristic curve analysis were performed to assess for diagnostic performance. Five biomarkers, including human α-defensin 1-3, neutrophil elastase 2, bactericidal/permeability-increasing protein, neutrophil gelatinase-associated lipocalin, and lactoferrin, correctly predicted the MSIS classification of all patients in this study, with 100% sensitivity and specificity for the diagnosis of PJI. An additional eight biomarkers demonstrated excellent diagnostic strength, with an area under the curve of greater than 0.9. Synovial fluid biomarkers exhibit a high accuracy in diagnosing PJI, even when including patients with systemic inflammatory disease and those receiving antibiotic treatment. Considering that these biomarkers match the results of the more complex MSIS definition of PJI, we believe that synovial fluid biomarkers can be a valuable addition to the methods utilized for the diagnosis of infection. Level II, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  3. Effects of CO2-rich fluids on a redbed reservoir: outcrop analogue study from the Buntsandstein (Germany)

    NASA Astrophysics Data System (ADS)

    Kasch, N.; Kley, J.; Koester, J.; van Geldern, R.; Wehrer, M.; Wendler, J.

    2010-12-01

    Carbon capture and storage (CCS) in saline aquifers will induce fluid-rock interactions, with effects on the mineralogy and physical properties of the reservoir. These effects are difficult to study in real reservoirs. Outcrop analogues provide access to relatively large rock volumes, but it may be difficult to prove that CO2 was involved in the mineral reactions observed. We present circumstantial evidence for the presence of CO2-rich fluids during the alteration of Triassic Buntsandstein redbeds from Germany. Fluid-rock interaction there is evidenced by localized bleaching of the red sandstones in fringes of a few mm to a few cm width along joints and fine cracks. The fringes can be traced along individual joints for a few dm to m. 3D geometric analysis on a cm scale shows that the bleached cracks form a complex interconnected network. On the outcrop scale, bleaching is essentially restricted to one north-trending joint set which is parallel to Miocene basalt dikes in the area. In underground salt mines, the dikes have caused bleaching of potassium salt minerals along their contacts. In the same mines CO2 is found trapped within rock salt along north-trending fractures, sometimes causing violent gas eruptions during mining operations. Together, these observations suggest that bleaching along north-trending joints in the Buntsandstein is causally related to the migration of CO2-rich fluids associated with the basalt volcanism. Today, CO2 ascends in CO2-enriched waters. We analyzed 12 samples of such waters. Their δ18O values correspond to meteoric waters. The δ13C (DIC) values of four water samples show signatures typical of volcanogenic CO2. Five samples contain mixed signals of volcanogenic and carbonatic CO2 or biogenic CO2 from soil. Volcanogenic and carbonatic CO2 are restricted to waters interpreted to rise along NW-SE striking basement faults. The switch of preferential fluid channeling from N-trending fractures in Tertiary time to NW-trending fractures

  4. Synovial fluid bupivacaine concentrations following single intra-articular injection in normal and osteoarthritic canine stifles.

    PubMed

    Barry, S L; Martinez, S A; Davies, N M; Remsberg, C M; Sayre, C L; Bachelez, A

    2015-02-01

    Intra-articular bupivacaine helps alleviate pain in animals receiving joint surgery, but its use has become controversial as ex vivo studies have illuminated the potential for chondrotoxicity. Such studies typically involve cell cultures incubated in solutions containing high bupivacaine concentrations for long durations. The aim of this study was to measure the actual synovial fluid bupivacaine concentrations after intra-articular injection. Eight healthy beagles with normal stifles and 22 large and giant-breed dogs with stifle osteoarthritis (OA) were treated with a single intra-articular injection of bupivacaine (1 mg/kg) into a stifle. Joint fluid samples were taken from the treated stifle immediately after injection and 30 min after injection and analyzed for bupivacaine concentrations. Immediately after injection, the median bupivacaine concentrations in normal and OA stifles were 3.6 and 2.5 mg/mL, respectively. Thirty minutes after injection, bupivacaine concentrations in normal and OA stifles were 0.4 and 0.6 mg/mL, respectively. These results provide insight into the pharmacokinetics of bupivacaine after injection into a joint. Given its immediate dilution and rapid drop in synovial fluid concentration, bupivacaine is unlikely to damage chondrocytes when administered as a single intra-articular injection. © 2014 John Wiley & Sons Ltd.

  5. Clumped isotopes reveal the influence of deformation style on fluid flow and cementation along the Moab Fault, Paradox Basin, Utah

    NASA Astrophysics Data System (ADS)

    Huntington, K. W.; Bergman, S.; Crider, J. G.

    2012-12-01

    distribution of low-temperature cements argues for rapid penetration of surface waters flowing down intensely-jointed fault intersections and suggests that deformation-band faults served as low-permeability baffles, preventing lateral migration of cold fluids. This interpretation is consistent with the cathodoluminescence patterns and δ18O and δ13C values of the samples, and confirms the important role of structures in transmission and compartmentalization of fluids in porous rocks. Our study illustrates how clumped isotope thermometry can aid in understanding interactions of mechanical, chemical, and transport processes associated with fractures and faults.

  6. A Systems Biology Approach to Synovial Joint Lubrication in Health, Injury, and Disease

    PubMed Central

    Hui, Alexander Y.; McCarty, William J.; Masuda, Koichi; Firestein, Gary S.; Sah, Robert L.

    2013-01-01

    The synovial joint contains synovial fluid (SF) within a cavity bounded by articular cartilage and synovium. SF is a viscous fluid that has lubrication, metabolic, and regulatory functions within synovial joints. SF contains lubricant molecules, including proteoglycan-4 and hyaluronan. SF is an ultrafiltrate of plasma with secreted contributions from cell populations lining and within the synovial joint space, including chondrocytes and synoviocytes. Maintenance of normal SF lubricant composition and function are important for joint homeostasis. In osteoarthritis, rheumatoid arthritis, and joint injury, changes in lubricant composition and function accompany alterations in the cytokine and growth factor environment and increased fluid and molecular transport through joint tissues. Thus, understanding the synovial joint lubrication system requires a multi-faceted study of the various parts of the synovial joint and their interactions. Systems biology approaches at multiple scales are being used to describe the molecular, cellular, and tissue components and their interactions that comprise the functioning synovial joint. Analyses of the transcriptome and proteome of SF, cartilage, and synovium suggest that particular molecules and pathways play important roles in joint homeostasis and disease. Such information may be integrated with physicochemical tissue descriptions to construct integrative models of the synovial joint that ultimately may explain maintenance of health, recovery from injury, or development and progression of arthritis. PMID:21826801

  7. Two‐phase designs for joint quantitative‐trait‐dependent and genotype‐dependent sampling in post‐GWAS regional sequencing

    PubMed Central

    Espin‐Garcia, Osvaldo; Craiu, Radu V.

    2017-01-01

    ABSTRACT We evaluate two‐phase designs to follow‐up findings from genome‐wide association study (GWAS) when the cost of regional sequencing in the entire cohort is prohibitive. We develop novel expectation‐maximization‐based inference under a semiparametric maximum likelihood formulation tailored for post‐GWAS inference. A GWAS‐SNP (where SNP is single nucleotide polymorphism) serves as a surrogate covariate in inferring association between a sequence variant and a normally distributed quantitative trait (QT). We assess test validity and quantify efficiency and power of joint QT‐SNP‐dependent sampling and analysis under alternative sample allocations by simulations. Joint allocation balanced on SNP genotype and extreme‐QT strata yields significant power improvements compared to marginal QT‐ or SNP‐based allocations. We illustrate the proposed method and evaluate the sensitivity of sample allocation to sampling variation using data from a sequencing study of systolic blood pressure. PMID:29239496

  8. One Sample, One Shot - Evaluation of sample preparation protocols for the mass spectrometric proteome analysis of human bile fluid without extensive fractionation.

    PubMed

    Megger, Dominik A; Padden, Juliet; Rosowski, Kristin; Uszkoreit, Julian; Bracht, Thilo; Eisenacher, Martin; Gerges, Christian; Neuhaus, Horst; Schumacher, Brigitte; Schlaak, Jörg F; Sitek, Barbara

    2017-02-10

    The proteome analysis of bile fluid represents a promising strategy to identify biomarker candidates for various diseases of the hepatobiliary system. However, to obtain substantive results in biomarker discovery studies large patient cohorts necessarily need to be analyzed. Consequently, this would lead to an unmanageable number of samples to be analyzed if sample preparation protocols with extensive fractionation methods are applied. Hence, the performance of simple workflows allowing for "one sample, one shot" experiments have been evaluated in this study. In detail, sixteen different protocols implying modifications at the stages of desalting, delipidation, deglycosylation and tryptic digestion have been examined. Each method has been individually evaluated regarding various performance criteria and comparative analyses have been conducted to uncover possible complementarities. Here, the best performance in terms of proteome coverage has been assessed for a combination of acetone precipitation with in-gel digestion. Finally, a mapping of all obtained protein identifications with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) revealed several proteins easily detectable in bile fluid. These results can build the basis for future studies with large and well-defined patient cohorts in a more disease-related context. Human bile fluid is a proximal body fluid and supposed to be a potential source of disease markers. However, due to its biochemical composition, the proteome analysis of bile fluid still represents a challenging task and is therefore mostly conducted using extensive fractionation procedures. This in turn leads to a high number of mass spectrometric measurements for one biological sample. Considering the fact that in order to overcome the biological variability a high number of biological samples needs to be analyzed in biomarker discovery studies, this leads to the dilemma of an unmanageable number of

  9. Biodynamic Performance of Hyaluronic Acid versus Synovial fluid of the Knee for Osteoarthritic Therapy

    PubMed Central

    Corvelli, Michael; Che, Bernadette; Saeui, Christopher; Singh, Anirudha; Elisseeff, Jennifer

    2015-01-01

    Hyaluronic acid (HA), a natural biomaterial present in healthy joints but depleted in osteoarthritis (OA), has been employed clinically to provide symptomatic relief of joint pain. Joint movement combined with a reduced joint lubrication in osteoarthritic knees can result in increased wear and tear, chondrocyte apoptosis, and inflammation, leading to cascading cartilage deterioration. Therefore, development of an appropriate cartilage model and evaluation for its friction properties with potential lubricants in different conditions is necessary, which can closely resemble a mechanically induced OA cartilage. Additionally, the comparison of different models with and without endogenous lubricating surface zone proteins, such as PRG4 promotes a well-rounded understanding of cartilage lubrication. In this study, we present our findings on the lubricating effects of HA on different articular cartilage model surfaces in comparison to synovial fluid, a physiological lubricating biomaterial. The mechanical testings data demonstrated that HA reduced average static and kinetic friction coefficient values of the cartilage samples by 75% and 70%, respectively. Furthermore, HA mimicked the friction characteristics of freshly harvested natural synovial fluid throughout all tested and modeled OA conditions with no statistically significant difference. These characteristics led us to exclusively identify HA as an effective boundary layer lubricant in the technology that we develop to treat OA [Singh et al. 2104]. PMID:25858258

  10. Synovial fluid hyaluronan mediates MSC attachment to cartilage, a potential novel mechanism contributing to cartilage repair in osteoarthritis using knee joint distraction

    PubMed Central

    Mastbergen, Simon C; Jones, Elena; Calder, Stuart J; Lafeber, Floris P J G; McGonagle, Dennis

    2016-01-01

    Objectives Knee joint distraction (KJD) is a novel, but poorly understood, treatment for osteoarthritis (OA) associated with remarkable ‘spontaneous’ cartilage repair in which resident synovial fluid (SF) multipotential mesenchymal stromal cells (MSCs) may play a role. We hypothesised that SF hyaluronic acid (HA) inhibited the initial interaction between MSCs and cartilage, a key first step to integration, and postulate that KJD environment favoured MSC/cartilage interactions. Methods Attachment of dual-labelled SF-MSCs were assessed in a novel in vitro human cartilage model using OA and rheumatoid arthritic (RA) SF. SF was digested with hyaluronidase (hyase) and its effect on adhesion was observed using confocal microscopy. MRI and microscopy were used to image autologous dual-labelled MSCs in an in vivo canine model of KJD. SF-HA was investigated using gel electrophoresis and densitometry. Results Osteoarthritic-synovial fluid (OA-SF) and purified high molecular weight (MW) HA inhibited SF-MSC adhesion to plastic, while hyase treatment of OA-SF but not RA-SF significantly increased MSC adhesion to cartilage (3.7-fold, p<0.05) These differences were linked to the SF mediated HA-coat which was larger in OA-SF than in RA-SF. OA-SF contained >9 MDa HA and this correlated with increases in adhesion (r=0.880). In the canine KJD model, MSC adhesion to cartilage was evident and also dependent on HA MW. Conclusions These findings highlight an unappreciated role of SF-HA on MSC interactions and provide proof of concept that endogenous SF-MSCs are capable of adhering to cartilage in a favourable biochemical and biomechanical environment in OA distracted joints, offering novel one-stage strategies towards joint repair. PMID:25948596

  11. Simulation Of The Synovial Fluid In A Deformable Cavity

    NASA Astrophysics Data System (ADS)

    Martinez-Gutierrez, Nancy; Ibarra-Bracamontes, Laura A.

    2016-11-01

    The main components of a synovial joint are a cartilage and a biofluid known as the synovial fluid. The results were obtained using the FLUENT software to simulate the behavior of the synovial fluid within a deformable cavity with a simple geometry. The cartilage is represented as a porous region. By reducing the available region for the fluid, a fluid displacement into the cartilage is induced. The total pressure reached in the interface of the deformable cavity and the porous region is presented. The geometry and properties of the system are scaled to values found in a knee joint. The effect of deformation rate, fluid viscosity and properties of the porous medium on the total pressure reached are analyzed. The higher pressures are reached either for high deformation rate or when the fluid viscosity increases. This study was supported by the Mexican Council of Science and Technology (CONACyT) and by the Scientific Research Coordination of the University of Michoacan in Mexico.

  12. An evaluation of analytical methods, air sampling techniques, and airborne occupational exposure of metalworking fluids.

    PubMed

    Verma, Dave K; Shaw, Don S; Shaw, M Lorraine; Julian, Jim A; McCollin, Shari-Ann; des Tombe, Karen

    2006-02-01

    This article summarizes an assessment of air sampling and analytical methods for both oil and water-based metalworking fluids (MWFs). Three hundred and seventy-four long-term area and personal airborne samples were collected at four plants using total (closed-face) aerosol samplers and thoracic samplers. A direct-reading device (DustTrak) was also used. The processes sampled include steel tube making, automotive component manufacturing, and small part manufacturing in a machine shop. The American Society for Testing and Materials (ASTM) Method PS42-97 of analysis was evaluated in the laboratory. This evaluation included sample recovery, determination of detection limits, and stability of samples during storage. Results of the laboratory validation showed (a) the sample recovery to be about 87%, (b) the detection limit to be 35 microg, and (c) sample stability during storage at room temperature to decline rapidly within a few days. To minimize sample loss, the samples should be stored in a freezer and analyzed within a week. The ASTM method should be the preferred method for assessing metalworking fluids (MWFs). The ratio of thoracic aerosol to total aerosol ranged from 0.6 to 0.7. A similar relationship was found between the thoracic extractable aerosol and total extractable aerosol. The DustTrak, with 10-microm sampling head, was useful in pinpointing the areas of potential exposure. MWF exposure at the four plants ranged from 0.04 to 3.84 mg/m3 with the geometric mean ranging between 0.22 to 0.59 mg/m3. Based on this data and the assumption of log normality, MWF exposures are expected to exceed the National Institute for Occupational Safety and Health recommended exposure limit of 0.5 mg/m3 as total mass and 0.4 mg/m3 as thoracic mass about 38% of the time. In addition to controlling airborne MWF exposure, full protection of workers would require the institution of programs for fluid management and dermal exposure prevention.

  13. Microscopical analysis of synovial fluid wear debris from failing CoCr hip prostheses

    NASA Astrophysics Data System (ADS)

    Ward, M. B.; Brown, A. P.; Cox, A.; Curry, A.; Denton, J.

    2010-07-01

    Metal on metal hip joint prostheses are now commonly implanted in patients with hip problems. Although hip replacements largely go ahead problem free, some complications can arise such as infection immediately after surgery and aseptic necrosis caused by vascular complications due to surgery. A recent observation that has been made at Manchester is that some Cobalt Chromium (CoCr) implants are causing chronic pain, with the source being as yet unidentified. This form of replacement failure is independent of surgeon or hospital and so some underlying body/implant interface process is thought to be the problem. When the synovial fluid from a failed joint is examined particles of metal (wear debris) can be found. Transmission Electron Microscopy (TEM) has been used to look at fixed and sectioned samples of the synovial fluid and this has identified fine (< 100 nm) metal and metal oxide particles within the fluid. TEM EDX and Electron Energy Loss Spectroscopy (EELS) have been employed to examine the composition of the particles, showing them to be chromium rich. This gives rise to concern that the failure mechanism may be associated with the debris.

  14. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples

    PubMed Central

    Chaya, DR; Parija, Subhash Chandra

    2014-01-01

    Introduction: Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. Materials and Methods: An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Results: Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Conclusions: Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis. PMID:24754027

  15. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    PubMed

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  16. [Pre-analytical quality in fluid samples cytopathology: Results of a survey from the French Society of Clinical Cytology].

    PubMed

    Courtade-Saïdi, Monique; Fleury Feith, Jocelyne

    2015-10-01

    The pre-analytical step includes sample collection, preparation, transportation and storage in the pathology unit where the diagnosis is performed. The pathologist ensures that pre-analytical conditions are in line with expectations. The lack of standardization for handling cytological samples makes this pre-analytical step difficult to harmonize. Moreover, this step depends on the nature of the sample: fresh liquid or fixed material, air-dried smears, liquid-based cytology. The aim of the study was to review the different practices in French structures of pathology on the pre-analytical phase concerning cytological fluids such as broncho-alveolar lavage (BALF), serous fluids and urine. A survey was conducted on the basis of the pre-analytical chapter of the ISO 15189 and sent to 191 French pathological structures (105 public and 86 private). Fifty-six laboratories replied to the survey. Ninety-five per cent have a computerized management system and 70% a manual on sample handling. The general instructions requested for the patients and sample identification were highly correctly filled with a short time routing and additional tests prescription. By contrast, information are variable concerning the clinical information requested and the type of tubes for collecting fluids and the volumes required as well as the actions taken in case of non-conformity. For the specific items concerning BALF, serous fluids and urine, this survey has shown a great heterogeneity according to sample collection, fixation and of clinical information. This survey demonstrates that the pre-analytical quality for BALF, serous fluids and urine is not optimal and that some corrections of the practices are recommended with a standardization of numerous steps in order to increase the reproducibility of additional tests such as immunocytochemistry, cytogenetic and molecular biology. Some recommendations have been written. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Rope-based oral fluid sampling for early detection of classical swine fever in domestic pigs at group level.

    PubMed

    Dietze, Klaas; Tucakov, Anna; Engel, Tatjana; Wirtz, Sabine; Depner, Klaus; Globig, Anja; Kammerer, Robert; Mouchantat, Susan

    2017-01-05

    Non-invasive sampling techniques based on the analysis of oral fluid specimen have gained substantial importance in the field of swine herd management. Methodological advances have a focus on endemic viral diseases in commercial pig production. More recently, these approaches have been adapted to non-invasive sampling of wild boar for transboundary animal disease detection for which these effective population level sampling methods have not been available. In this study, a rope-in-a-bait based oral fluid sampling technique was tested to detect classical swine fever virus nucleic acid shedding from experimentally infected domestic pigs. Separated in two groups treated identically, the course of the infection was slightly differing in terms of onset of the clinical signs and levels of viral ribonucleic acid detection in the blood and oral fluid. The technique was capable of detecting classical swine fever virus nucleic acid as of day 7 post infection coinciding with the first detection in conventional oropharyngeal swab samples from some individual animals. Except for day 7 post infection in the "slower onset group", the chances of classical swine fever virus nucleic acid detection in ropes were identical or higher as compared to the individual sampling. With the provided evidence, non-invasive oral fluid sampling at group level can be considered as additional cost-effective detection tool in classical swine fever prevention and control strategies. The proposed methodology is of particular use in production systems with reduced access to veterinary services such as backyard or scavenging pig production where it can be integrated in feeding or baiting practices.

  18. Two-phase designs for joint quantitative-trait-dependent and genotype-dependent sampling in post-GWAS regional sequencing.

    PubMed

    Espin-Garcia, Osvaldo; Craiu, Radu V; Bull, Shelley B

    2018-02-01

    We evaluate two-phase designs to follow-up findings from genome-wide association study (GWAS) when the cost of regional sequencing in the entire cohort is prohibitive. We develop novel expectation-maximization-based inference under a semiparametric maximum likelihood formulation tailored for post-GWAS inference. A GWAS-SNP (where SNP is single nucleotide polymorphism) serves as a surrogate covariate in inferring association between a sequence variant and a normally distributed quantitative trait (QT). We assess test validity and quantify efficiency and power of joint QT-SNP-dependent sampling and analysis under alternative sample allocations by simulations. Joint allocation balanced on SNP genotype and extreme-QT strata yields significant power improvements compared to marginal QT- or SNP-based allocations. We illustrate the proposed method and evaluate the sensitivity of sample allocation to sampling variation using data from a sequencing study of systolic blood pressure. © 2017 The Authors. Genetic Epidemiology Published by Wiley Periodicals, Inc.

  19. Major- and minor-metal composition of three distinct solid material fractions associated with Juan de Fuca hydrothermal fluids (northeast Pacific), and calculation of dilution fluid samples

    USGS Publications Warehouse

    Hinkley, T.K.; Seeley, J.L.; Tatsumoto, M.

    1988-01-01

    Three distinct types of solid material are associated with each sample of the hydrothermal fluid that was collected from the vents of the Southern Juan de Fuca Ridge. The solid materials appear to be representative of deposits on ocean floors near mid-ocean ridges, and interpretation of the chemistry of the hydrothermal solutions requires understanding of them. Sr isotopic evidence indicates that at least two and probably all three of these solid materials were removed from the solution with which they are associated, by precipitation or adsorption. This occurred after the "pure" hydrothermal fluid was diluted and thoroughly mixed with ambient seawater. The three types of solid materials, are, respectively, a coarse Zn- and Fe-rich material with small amounts of Na and Ca; a finer material also rich in Zn and Fe, but with alkali and alkaline-earth metals; and a scum composed of Ba or Zn, with either considerable Fe or Si, and Sr. Mineral identification is uncertain because of uncertain anion composition. Only in the cases of Ba and Zn were metal masses greater in solid materials than in the associated fluids. For all other metals measured, masses in fluids dwarf those in solids. The fluids themselves contain greater concentrations of all metals measured, except Mg, than seawater. We discuss in detail the relative merits of two methods of determining the mixing proportions of "pure" hydrothermal solution and seawater in the fluids, one based on Sr isotopes, and another previously used method based on Mg concentrations. Comparison of solute concentrations in the several samples shows that degree of dilution of "pure" hydrothermal solutions by seawater, and amounts of original solutes that were removed from it as solid materials, are not related. There is no clear evidence that appreciable amounts of solid materials were not conserved (lost) either during or prior to sample collection. ?? 1988.

  20. Fluid accumulation during acute kidney injury in the intensive care unit.

    PubMed

    Berthelsen, R E; Perner, A; Jensen, A K; Jensen, J-U; Bestle, M H

    2018-07-01

    Fluid therapy is a ubiquitous intervention in patients admitted to the intensive care unit, but positive fluid balance may be associated with poor outcomes and particular in patients with acute kidney injury. Studies describing this have defined fluid overload either at specific time points or considered patients with a positive mean daily fluid balance as fluid overloaded. We wished to detail this further and performed joint model analyses of the association between daily fluid balance and outcome represented by mortality and renal recovery in patients admitted with acute kidney injury. We did a retrospective cohort study of patients admitted to the intensive care unit with acute kidney injury during a 2-year observation period. We used serum creatinine measurements to identify patients with acute kidney injury and collected sequential daily fluid balance during the first 5 days of admission to the intensive care unit. We used joint modelling techniques to correlate the development of fluid overload with survival and renal recovery adjusted for age, gender and disease severity. The cohort contained 863 patients with acute kidney injury of whom 460 (53%) and 254 (29%) developed 5% and 10% fluid overload, respectively. We found that both 5% and 10% fluid overload was correlated with reduced survival and renal recovery. Joint model analyses of fluid accumulation in patients admitted to the intensive care unit with acute kidney injury confirm that even a modest degree of fluid overload (5%) may be negatively associated with both survival and renal recovery. © 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Multiple joint metastasis of a transitional cell carcinoma in a dog.

    PubMed

    Colledge, Sarah L; Raskin, Rose E; Messick, Joanne B; Tiffany Reed, L; Wigle, William L; Balog, Kelley A

    2013-06-01

    An 8-year-old castrated male hound mix was referred to the Purdue University Veterinary Teaching Hospital for severe lameness, pollakiuria, and dyschezia. On presentation, the dog was nonweight bearing on the right rear limb and the right carpus was diffusely swollen. Synovial fluid analysis from the right carpus revealed a population of epithelial cells displaying marked anisocytosis, anisokaryosis, multinucleation, and prominent, variably sized nucleoli. A metastatic carcinoma with presumed prostatic or urothelial origin was diagnosed based on cytomorphology. Subsequent cytologic evaluation of peripheral lymph nodes revealed the presence of a similar neoplastic population. The dog was euthanized and synovial fluid from both stifle joints, as well as impression smears of the prostate gland, were collected. Carcinoma cells were identified in each stifle joint and in the prostate gland. Immunocytochemistry was performed on synovial fluid smears from 2 of the joints (right stifle and right carpus) and on impression smears of the prostate gland. The neoplastic population in the joints and prostate gland showed strong immunoreactivity to uroplakin III, a urothelial marker, indicating metastasis of a transitional cell carcinoma to multiple joints. In addition, evidence for epithelial to mesenchymal transition was identified using cytokeratin, an epithelial marker, and vimentin, a mesenchymal marker. A necropsy was performed and histopathology confirmed the presence of metastatic transitional cell carcinoma in various tissues. This case illustrates the importance of considering metastatic disease when a patient is presented with severe lameness and joint pain, and the clinical utility of synovial fluid cytology for diagnosis of metastasis in these cases. © 2013 American Society for Veterinary Clinical Pathology.

  2. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  3. Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping

    PubMed Central

    Liu, Jixiao; Fu, Hai; Yang, Tianhang; Li, Songjing

    2015-01-01

    To sequentially handle fluids is of great significance in quantitative biology, analytical chemistry, and bioassays. However, the technological options are limited when building such microfluidic sequential processing systems, and one of the encountered challenges is the need for reliable, efficient, and mass-production available microfluidic pumping methods. Herein, we present a bubble-free and pumping-control unified liquid handling method that is compatible with large-scale manufacture, termed multilayer microfluidic sample isolated pumping (mμSIP). The core part of the mμSIP is the selective permeable membrane that isolates the fluidic layer from the pneumatic layer. The air diffusion from the fluidic channel network into the degassing pneumatic channel network leads to fluidic channel pressure variation, which further results in consistent bubble-free liquid pumping into the channels and the dead-end chambers. We characterize the mμSIP by comparing the fluidic actuation processes with different parameters and a flow rate range of 0.013 μl/s to 0.097 μl/s is observed in the experiments. As the proof of concept, we demonstrate an automatic sequential fluid handling system aiming at digital assays and immunoassays, which further proves the unified pumping-control and suggests that the mμSIP is suitable for functional microfluidic assays with minimal operations. We believe that the mμSIP technology and demonstrated automatic sequential fluid handling system would enrich the microfluidic toolbox and benefit further inventions. PMID:26487904

  4. FLUID SELECTING APPARATUS

    DOEpatents

    Stinson, W.J.

    1958-09-16

    A valve designed to selectively sample fluids from a number of sources is described. The valve comprises a rotatable operating lever connected through a bellows seal to a rotatable assembly containing a needle valve, bearings, and a rotational lock. The needle valve is connected through a flexible tube to the sample fluid outlet. By rotating the lever the needle valve is placed over . one of several fluid sources and locked in position so that the fluid is traasferred through the flexible tubing and outlet to a remote sampling system. The fluids from the nonselected sources are exhausted to a waste line. This valve constitutes a simple, dependable means of selecting a sample from one of several scurces.

  5. Filtration rate dependence of hyaluronan reflection by joint-to-lymph barrier: evidence for concentration polarisation

    PubMed Central

    Sabaratnam, S; Mason, RM; Levick, JR

    2004-01-01

    Hyaluronan (HA), a component of synovial fluid, buffers fluid loss from joints. To explain this, a quantitative theory for HA concentration polarisation at a partially sieving synovial lining was developed. The theory predicts a fall in HA reflected fraction R with increased filtration rate. To test this, knees of anaesthetised rabbits were infused with HA and fluorescein–dextran (FD) at constant trans-synovial filtration rates of 6–89 μl min−1. Samples of femoral lymph, mixed intra-articular fluid and subsynovial fluid after ≥ 3 h were analysed by high-performance liquid chromatography. R was calculated as (1 – downstream/upstream concentration), using [FD] to adjust for joint lymph dilution in femoral lymph. Intra-articular HA concentration after ≥ 3 h, 0.47 ± 0.02 mg ml−1 (mean ±s.e.m., n = 31), exceeded the infusate concentration, 0.20 mg ml−1, while subsynovial and lymph [HA] were reduced relative to [FD]. The changes in [HA] demonstrated synovial molecular sieving of HA. R from cavity to lymph (Rlymph) fell monotonically from 0.93 at 6 μl min−1 to 0.14 at 89 μl min−1 (P < 0.0001, regression analysis, n = 33). R values calculated from the intra-articular HA accumulation (Rasp) or the low subsynovial concentrations (Rsyn) were similar negative functions of filtration rate. R for lymphatic capillary endothelium (Rendo), calculated from lymph/subsynovial concentration ratios, was effectively zero (−0.03 ± 0.18, n = 21), confirming that synovium, not initial lymphatic endothelium, is the reflection site. Logarithmic linearisation of the results evaluated the synovial HA reflection coefficient as 0.91. In conclusion, the existence of concentration polarisation during joint fluid drainage was supported by the demonstration of a negative relation between filtration rate and Rlymph, Rasp and Rsyn. PMID:15073278

  6. 46 CFR 56.30-3 - Piping joints (reproduces 110).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Piping joints (reproduces 110). 56.30-3 Section 56.30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... joint tightness, mechanical strength and the nature of the fluid handled. ...

  7. 46 CFR 56.30-3 - Piping joints (reproduces 110).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Piping joints (reproduces 110). 56.30-3 Section 56.30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... joint tightness, mechanical strength and the nature of the fluid handled. ...

  8. 46 CFR 56.30-3 - Piping joints (reproduces 110).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Piping joints (reproduces 110). 56.30-3 Section 56.30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... joint tightness, mechanical strength and the nature of the fluid handled. ...

  9. 46 CFR 56.30-3 - Piping joints (reproduces 110).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Piping joints (reproduces 110). 56.30-3 Section 56.30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... joint tightness, mechanical strength and the nature of the fluid handled. ...

  10. 46 CFR 56.30-3 - Piping joints (reproduces 110).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Piping joints (reproduces 110). 56.30-3 Section 56.30-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... joint tightness, mechanical strength and the nature of the fluid handled. ...

  11. Synovial fluid hyaluronan mediates MSC attachment to cartilage, a potential novel mechanism contributing to cartilage repair in osteoarthritis using knee joint distraction.

    PubMed

    Baboolal, Thomas G; Mastbergen, Simon C; Jones, Elena; Calder, Stuart J; Lafeber, Floris P J G; McGonagle, Dennis

    2016-05-01

    Knee joint distraction (KJD) is a novel, but poorly understood, treatment for osteoarthritis (OA) associated with remarkable 'spontaneous' cartilage repair in which resident synovial fluid (SF) multipotential mesenchymal stromal cells (MSCs) may play a role. We hypothesised that SF hyaluronic acid (HA) inhibited the initial interaction between MSCs and cartilage, a key first step to integration, and postulate that KJD environment favoured MSC/cartilage interactions. Attachment of dual-labelled SF-MSCs were assessed in a novel in vitro human cartilage model using OA and rheumatoid arthritic (RA) SF. SF was digested with hyaluronidase (hyase) and its effect on adhesion was observed using confocal microscopy. MRI and microscopy were used to image autologous dual-labelled MSCs in an in vivo canine model of KJD. SF-HA was investigated using gel electrophoresis and densitometry. Osteoarthritic-synovial fluid (OA-SF) and purified high molecular weight (MW) HA inhibited SF-MSC adhesion to plastic, while hyase treatment of OA-SF but not RA-SF significantly increased MSC adhesion to cartilage (3.7-fold, p<0.05) These differences were linked to the SF mediated HA-coat which was larger in OA-SF than in RA-SF. OA-SF contained >9 MDa HA and this correlated with increases in adhesion (r=0.880). In the canine KJD model, MSC adhesion to cartilage was evident and also dependent on HA MW. These findings highlight an unappreciated role of SF-HA on MSC interactions and provide proof of concept that endogenous SF-MSCs are capable of adhering to cartilage in a favourable biochemical and biomechanical environment in OA distracted joints, offering novel one-stage strategies towards joint repair. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Magneto-therapy of human joint cartilage.

    PubMed

    Wierzcholski, Krzysztof; Miszczak, Andrzej

    2017-01-01

    The topic of the present paper concerns the human joint cartilage therapy performed by the magnetic induction field. There is proved the thesis that the applied magnetic field for concrete cartilage illness should depend on the proper relative and concrete values of applied magnetic induction, intensity as well the time of treatment duration. Additionally, very important are frequencies and amplitudes of magnetic field as well as magnetic permeability of the synovial fluid. The research methods used in this paper include: magnetic induction field produced by a new Polish and German magneto electronic devices for the therapy of human joint cartilage diseases, stationary and movable magnetic applicators, magnetic bandage, ferrofluid injections, author's experience gained in Germany research institutes and practical results after measurements and information from patients. The results of this paper concern concrete parameters of time dependent electro-magnetic field administration during the joint cartilage therapy duration and additionally concern the corollaries which are implied from reading values gained on the magnetic induction devices. The main conclusions obtained in this paper are as follows: Time dependent magnetic induction field increases the dynamic viscosity of movable synovial fluid and decreases symptoms of cartilage illness for concrete intensity of magnetic field and concrete field line architecture. The ferrofluid therapy and phospholipids bilayer simultaneously with the administrated external electromagnetic field, increases the dynamic viscosity of movable synovial fluid.

  13. Diagnostic test accuracy and prevalence inferences based on joint and sequential testing with finite population sampling.

    PubMed

    Su, Chun-Lung; Gardner, Ian A; Johnson, Wesley O

    2004-07-30

    The two-test two-population model, originally formulated by Hui and Walter, for estimation of test accuracy and prevalence estimation assumes conditionally independent tests, constant accuracy across populations and binomial sampling. The binomial assumption is incorrect if all individuals in a population e.g. child-care centre, village in Africa, or a cattle herd are sampled or if the sample size is large relative to population size. In this paper, we develop statistical methods for evaluating diagnostic test accuracy and prevalence estimation based on finite sample data in the absence of a gold standard. Moreover, two tests are often applied simultaneously for the purpose of obtaining a 'joint' testing strategy that has either higher overall sensitivity or specificity than either of the two tests considered singly. Sequential versions of such strategies are often applied in order to reduce the cost of testing. We thus discuss joint (simultaneous and sequential) testing strategies and inference for them. Using the developed methods, we analyse two real and one simulated data sets, and we compare 'hypergeometric' and 'binomial-based' inferences. Our findings indicate that the posterior standard deviations for prevalence (but not sensitivity and specificity) based on finite population sampling tend to be smaller than their counterparts for infinite population sampling. Finally, we make recommendations about how small the sample size should be relative to the population size to warrant use of the binomial model for prevalence estimation. Copyright 2004 John Wiley & Sons, Ltd.

  14. Extracting metalworking fluid aerosol samples in cassettes by provisional ASTM and NIOSH methods.

    PubMed

    Harper, Martin

    2002-01-01

    Recent provisional methods for the determination of metalworking fluid aerosol in workplace air involve a solvent extraction procedure to separate the nonvolatile fraction of the fluid from insoluble material such as metal turnings and dirt. The procedure calls for preweighing a filter (W1) and assembling it into a cassette and taking a sample. In the laboratory the filter is removed from the cassette, desiccated to remove any collected water or other volatile substances, and weighed again (W2). The filter is then extracted in an organic solvent blend, allowed to dry, and weighed a final time (W3). The total weight collected by the filter is given by (W2-W1), and the weight of (nonvolatile) metalworking fluid collected is given by (W2-W3). The extraction step can take place within a cassette housing if it is relatively inert to the solvent blend used. The extraction of four metalworking fluids (straight oil, soluble oil, synthetic and semisynthetic) within disposable polypropylene cassettes was investigated using the same protocol used to evaluate the original method. For all fluids the extraction efficiency was greater than 95% with a precision better than 5%. The mean blank contribution to the extraction step was 16 micrograms. Blanks were also evaluated after storage, and after transport and storage. A small additional blank contribution could be removed by desiccation. The limits of detection and quantitation of the extraction step were calculated to be 28 and 94 micrograms, respectively.

  15. [Effects of exercise on joints.

    PubMed

    Moriyama, Hideki

    Joints are composed of several different tissues(cartilage, capsule, meniscus, and ligament), and articular cartilage plays an important role in maintaining mechanical competence during exercise. Weight-bearing exercise has several benefit, including improved blood and synovial fluid circulation in a given joint. Consistent moderate activities facilitate cycles of anabolism and catabolism. Mechanical stresses are crucial for the maintenance of the morphologic and functional integrity of articular cartilage. Healthy cartilage is exposed by hydrostatic pressure and tensile strain, when cartilage degeneration develops, abnormal cartilage is exposed by shear stress. Moderate(physiological)exercise is characterized by a range of equilibrium between matrix anabolic and catabolic processes, or anabolism beyond catabolism. Joints are susceptible to insufficient or excessive activities, leading to joint degeneration. Lack of exercise is known to induce joint contracture seen clinically as a consequence of disuse changes, and excess mechanical stresses induce joint destruction such as osteoarthritis. Joint diseases resulting from insufficient or excessive activities are new and major challenging issues with our aging population. Thus, it is highly desirable to have an effective and efficient treatment to improve and protect against these joint diseases, and thereby to solve these clearly unanswered issues.

  16. Correlation of dickkopf-1 concentrations in plasma and synovial fluid to the severity of radiographic signs of equine osteoarthritis.

    PubMed

    Mills, Jillian S; Kinsley, Marc A; Peters, Duncan F; Weber, Patty S D; Shearer, Tara R; Pease, Anthony P

    2017-09-12

    The purpose of this study was to determine whether there was a correlation between circulating and intra-synovial Dkk-1 and radiographic signs of equine osteoarthritis. Circulating and intra-synovial Dkk-1 levels were measured in clinical cases using a commercially available human Dkk-1 ELISA. Radiographs were performed of the joints from which fluid was collected and these were assessed and scored by a boarded radiologist for joint narrowing, subchondral bone sclerosis, subchondral bone lysis, and periarticular modelling. Comparisons were made between radiographic scores and the concentrations of Dkk-1 using a Kruskal-Wallis one-way ANOVA. Correlations were calculated using Kendall's statistic. A total of 42 synovial fluid samples from 21 horses were collected and used in the analysis. No significant correlation was identified between Dkk-1 concentrations and radiographic signs of osteoarthritis. Intra-synovial Dkk-1 concentrations were significantly greater (p <0.001) in low motion joints (mean concentration, 232.68 pg/mL; range, 109.07-317.17) when compared to high-motion joints (28.78 pg/mL; 0.05-186.44 pg/mL) (p <0.001). Low motion joints have significantly higher concentrations of Dkk-1 compared to high motion joints. Further research is needed to establish the importance of this finding and whether potential diagnostic or therapeutic applications of Dkk-1 exist in the horse.

  17. Solid-Phase Extraction Strategies to Surmount Body Fluid Sample Complexity in High-Throughput Mass Spectrometry-Based Proteomics

    PubMed Central

    Bladergroen, Marco R.; van der Burgt, Yuri E. M.

    2015-01-01

    For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations. PMID:25692071

  18. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, Robert E.

    2015-12-08

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  19. Highly simplified lateral flow-based nucleic acid sample preparation and passive fluid flow control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, Robert B.

    Highly simplified lateral flow chromatographic nucleic acid sample preparation methods, devices, and integrated systems are provided for the efficient concentration of trace samples and the removal of nucleic acid amplification inhibitors. Methods for capturing and reducing inhibitors of nucleic acid amplification reactions, such as humic acid, using polyvinylpyrrolidone treated elements of the lateral flow device are also provided. Further provided are passive fluid control methods and systems for use in lateral flow assays.

  20. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  1. Retrospective evaluation of the efficacy of isolating bacteria from synovial fluid in dogs with suspected septic arthritis.

    PubMed

    Scharf, V F; Lewis, S T; Wellehan, J F; Wamsley, H L; Richardson, R; Sundstrom, D A; Lewis, D D

    2015-06-01

    To evaluate the efficacy of synovial fluid culture in obtaining the causative organism from dogs with suspected septic arthritis. In this retrospective evaluation, synovial fluid cytology and microbiology submissions from dogs with suspected septic arthritis from March 2007 to August 2011 were reviewed. Synovial fluid cytology consistent with joint sepsis was identified. Cultures of synovial fluid from dogs with clinical histories and abnormalities consistent with septic arthritis were used to evaluate the efficacy of bacterial isolation. In total, 36 dogs met the inclusion criteria. Initial aerobic cultures of joint fluid yielded bacterial growth in 44% of these dogs. All anaerobic cultures were negative. In 19% of the dogs with positive cultures, antibiotics had been administered prior to arthrocentesis compared with 10% of dogs with negative cultures. There was no association between culture efficacy and the administration of antimicrobial treatment prior to synovial fluid culture or recent surgery involving the affected joint (P=0.637 and P=0.106, respectively). Culture of synovial fluid from dogs with suspected septic arthritis has a low yield, necessitating a more effective means of identifying bacteria from suspected septic joints in dogs. © 2015 Australian Veterinary Association.

  2. Comparison of the nonionic contrast agents, iopromide and iotrolan, for positive-contrast arthrography of the scapulohumeral joint in dogs.

    PubMed

    van Bree, H; Van Rijssen, B; Tshamala, M; Maenhout, T

    1992-09-01

    Arthrographic quality and synovial inflammatory response were examined to compare the use of iopromide with that of iotrolan for arthrography of the scapulohumeral joint in 6 dogs. Radiographs obtained 1 and 3 minutes after injection of either nonionic compound were of similar quality, but radiographs obtained 5 minutes after injection of iotrolan were significantly (P less than 0.05) better than those obtained after injection of iopromide. Results of analysis of synovial fluid samples obtained at 1, 3, 7, and 14 days after injection of contrast media were not significantly different between the 2 groups. Histologic examination of synovium and articular cartilage 2 weeks after injection of iopromide or iotrolan revealed minimal inflammatory response for both contrast agents. Injection of iopromide and iotrolan into the scapulohumeral joints of dogs had less effect on synovial fluid than that reported after injection of ionic compounds.

  3. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  4. Synovitis induced by joint lavage with hypertonic saline solutions in healthy dairy calves

    PubMed Central

    Achard, Damien; Francoz, David; Desrochers, André; Girard, Christiane; Piché, Caroline

    2012-01-01

    The objective of this study was to evaluate the effect of a single joint lavage with 7.2% or 15% hypertonic saline solutions (HSS) on the tarsocrural joints of healthy calves. The tarsi of 10 calves were randomly lavaged with 7.2% HSS, 15% HSS, or isotonic saline. Synovial fluid samples were collected aseptically on days 1 (before joint lavage), 2, 3, 4, and 8 for complete cytological analysis. Lameness, joint swelling, and pain were recorded daily. Calves were euthanized on day 8 for gross and histological analyses of synovial membranes and articular cartilage. Synovitis was evaluated using a scoring system reflecting inflammatory changes in synovial membranes. Joints irrigated with HSS were more distended and painful compared with isotonic control joints. Swelling decreased consistently in the joints lavaged with 7.2% HSS, whereas it remained unchanged in joints lavaged with 15% HSS. Slight to moderate lameness was observed in the joints lavaged with 15% HSS. In comparison to isotonic saline joints, total protein concentration was significantly increased on day 2 and 3 for the joints lavaged with 7.2% HSS (P ≤ 0.01) and on days 2, 3, and 4 in the joints lavaged with 15% HSS (P ≤ 0.0006). Gross and histological findings revealed that synovitis was more severe in the joints lavaged with 15% HSS but variable in the joints lavaged with 7.2% HSS. No significant differences were observed for the articular cartilage. Fifteen percent HSS is not recommended for joint lavage. Although irrigation with 7.2% HSS may induce a variable synovitis, it was found appropriate for joint lavage. Its effects on septic joints remain undetermined. PMID:23024450

  5. Effects of fluid-rock interactions on faulting within active fault zones - evidence from fault rock samples retrieved from international drilling projects

    NASA Astrophysics Data System (ADS)

    Janssen, C.; Wirth, R.; Kienast, M.; Yabe, Y.; Sulem, J.; Dresen, G. H.

    2015-12-01

    Chemical and mechanical effects of fluids influence the fault mechanical behavior. We analyzed fresh fault rocks from several scientific drilling projects to study the effects of fluids on fault strength. For example, in drill core samples on a rupture plane of an Mw 2.2 earthquake in a deep gold mine in South Africa the main shock occurred on a preexisting plane of weakness that was formed by fluid-rock interaction (magnesiohornblende was intensively altered to chlinochlore). The plane acted as conduit for hydrothermal fluids at some time in the past. The chemical influence of fluids on mineralogical alteration and geomechanical processes in fault core samples from SAFOD (San Andreas Fault Observatory at Depth) is visible in pronounced dissolution-precipitation processes (stylolites, solution seams) as well as in the formation of new phases. Detrital quartz and feldspar grains are partially dissolved and replaced by authigenic illite-smectite (I-S) mixed-layer clay minerals. Transmission Electron Microscopy (TEM) imaging of these grains reveals that the alteration processes and healing were initiated within pores and small intra-grain fissures. Newly formed phyllosilicates growing into open pore spaces likely reduced the fluid permeability. The mechanical influence of fluids is indicated by TEM observations, which document open pores that formed in-situ in the gouge material during or after deformation. Pores were possibly filled with formation water and/or hydrothermal fluids suggesting elevated fluid pressure preventing pore collapse. Fluid-driven healing of fractures in samples from SAFOD and the DGLab Gulf of Corinth project is visible in cementation. Cathodoluminescence microscopy (CL) reveals different generations of calcite veins. Differences in CL-colors suggest repeated infiltration of fluids with different chemical composition from varying sources (formation and meteoric water).

  6. Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

    NASA Technical Reports Server (NTRS)

    Tsuchiyama, A.; Miyake, A.; Zolensky, M. E.; Uesugi, K.; Nakano, T.; Takeuchi, A.; Suzuki, Y.; Yoshida, K.

    2014-01-01

    Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron

  7. Concentration polarization of hyaluronan on the surface of the synovial lining of infused joints

    PubMed Central

    Lu, Y; Levick, JR; Wang, W

    2004-01-01

    Hyaluronan (HA) in joints conserves the lubricating synovial fluid by making trans-synovial fluid escape almost insensitive to pressure elevation (e.g. effusions, joint flexion). This phenomenon, ‘outflow buffering’, was discovered during HA infusion into the rabbit knee joint cavity. It was also found that HA is partially reflected by the joint lining (molecular sieving), and that the reflected fraction R decreases as trans-synovial filtration rate Q is increased. It was postulated therefore that outflow buffering is mediated by HA reflection. Reflection creates a HA concentration polarization layer, the osmotic pressure of which opposes fluid loss. A steady-state, cross-flow ultrafiltration model was previously used to explain the outflow buffering and negative R-vs.-Q relation. However, the steady-state, cross-perfusion assumptions restricted the model's applicability for an infused, dead-end cavity or a non-infused joint during cyclical motion. We therefore developed a new, non-steady-state model which describes the time course of dead-end, partial HA ultrafiltration. The model describes the progressive build-up of a HA concentration polarization layer at the synovial surface over time. Using experimental parameter values, the model successfully accounts for the observed negative R-vs.-Q relation and shows that the HA reflected fraction (R) also depends on HA diffusivity, membrane area expansion and the synovial HA reflection coefficient. The non-steady-state model thus explains existing experimental work, and it is a key stage in understanding synovial fluid turnover in intact, moving, human joints or osteoarthritic joints treated by HA injections. PMID:15579541

  8. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.

    PubMed

    Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A

    2011-11-01

    Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should

  9. The Iceland Deep Drilling Project (IDDP): Deep Fluid Sampling in Fractured Quartz, Reykjanes Geothermal System, Iceland

    NASA Astrophysics Data System (ADS)

    Seward, R. J.; Reed, M. H.; Grist, H. R.; Fridriksson, T.; Danielsen, P.; Thorhallsson, S.; Elders, W. A.; Fridleifsson, G. O.

    2011-12-01

    In July of 2011 a fluid inclusion tool (FIT) was deployed in well RN-17b of the Reykjanes geothermal system, Iceland, with the goal of sampling fluids in situ at the deepest feed point in the well. The tool consists of a perforated stainless steel pipe containing eight stainless steel mesh canisters, each loaded with 10mm-scale blocks of thermally fractured quartz. Except for one control canister, in each canister the fractured quartz blocks were surrounded by a different grain size of SiO¬2 glass that ranged in size from 10μm-scale glass wool to cm-scale glass shards. The FIT was left in the well on a wireline at a depth of 2768m and retrieved after three weeks. The fluid at 2768m depth is known from November 2010 well logs to have a temperature of about 330°C and pressure of 170 bars, a pressure ~40 bar too high for boiling at that temperature. After retrieval, quartz in all of the canisters contained liquid-dominated fluid inclusions, but their quantity and size differed by canister. Groups of inclusions occur in healed fractures and both healed and open fracture surfaces are visible within single quartz blocks. Measurements on a heating and cooling stage yield approximant inclusion homogenization temperatures of 332°C and freezing points of -2.0°C. These measurements and a pressure of 170 bars yield trapping temperatures of 335°C and a NaCl weight percent of 3.4, both of which match known values, thus verifying that the device trapped fluids as intended. In upcoming studies, these fluids will be analyzed using bulk methods and LA-ICP-MS on individual inclusions. The glass added to the quartz blocks in the canisters allowed the Reykjanes fluids to precipitate enough quartz to heal fractures and trap fluids despite the fluid undersaturation in quartz. Almost all of the glass that was added to the canisters, 27 to 66 grams in each (except glass wool), was consumed in the experiment. Remaining glass was in the non-mesh bottom caps of the canisters where fluid

  10. Association of Fluid Intelligence and Psychiatric Disorders in a Population-Representative Sample of US Adolescents.

    PubMed

    Keyes, Katherine M; Platt, Jonathan; Kaufman, Alan S; McLaughlin, Katie A

    2017-02-01

    Despite long-standing interest in the association of psychiatric disorders with intelligence, few population-based studies of psychiatric disorders have assessed intelligence. To investigate the association of fluid intelligence with past-year and lifetime psychiatric disorders, disorder age at onset, and disorder severity in a nationally representative sample of US adolescents. National sample of adolescents ascertained from schools and households from the National Comorbidity Survey Replication-Adolescent Supplement, collected 2001 through 2004. Face-to-face household interviews with adolescents and questionnaires from parents were obtained. The data were analyzed from February to December 2016. DSM-IV mental disorders were assessed with the World Health Organization Composite International Diagnostic Interview, and included a broad range of fear, distress, behavior, substance use, and other disorders. Disorder severity was measured with the Sheehan Disability Scale. Fluid IQ measured with the Kaufman Brief Intelligence Test, normed within the sample by 6-month age groups. The sample included 10 073 adolescents (mean [SD] age, 15.2 [1.50] years; 49.0% female) with valid data on fluid intelligence. Lower mean (SE) IQ was observed among adolescents with past-year bipolar disorder (94.2 [1.69]; P = .004), attention-deficit/hyperactivity disorder (96.3 [0.91]; P = .002), oppositional defiant disorder (97.3 [0.66]; P = .007), conduct disorder (97.1 [0.82]; P = .02), substance use disorders (alcohol abuse, 96.5 [0.67]; P < .001; drug abuse, 97.6 [0.64]; P = .02), and specific phobia (97.1 [0.39]; P = .001) after adjustment for a wide range of potential confounders. Intelligence was not associated with posttraumatic stress disorder, eating disorders, and anxiety disorders other than specific phobia, and was positively associated with past-year major depression (mean [SE], 100 [0.5]; P = .01). Associations of fluid intelligence with

  11. Evaluation of clinical, radiographical and cytological findings compared to arthroscopic findings in shoulder joint lameness in the dog.

    PubMed

    Akerblom, S; Sjöström, L

    2007-01-01

    Forty-two dogs with lameness emanating from the shoulder joint were studied by clinical examination, radiographic examination, joint fluid analysis, and arthroscopic examination, following a set protocol. Dogs with mild clinical signs, absent or mild radiographic signs of osteoarthrosis, and without or with very mild changes in the synovial fluid, may still have moderate to severe degenerative pathological changes in the shoulder joint.

  12. A mixed-penalty biphasic finite element formulation incorporating viscous fluids and material interfaces.

    PubMed

    Chan, B; Donzelli, P S; Spilker, R L

    2000-06-01

    The fluid viscosity term of the fluid phase constitutive equation and the interface boundary conditions between biphasic, solid and fluid domains have been incorporated into a mixed-penalty finite element formulation of the linear biphasic theory for hydrated soft tissue. The finite element code can now model a single-phase viscous incompressible fluid, or a single-phase elastic solid, as limiting cases of a biphasic material. Interface boundary conditions allow the solution of problems involving combinations of biphasic, fluid and solid regions. To incorporate these conditions, the volume-weighted mixture velocity is introduced as a degree of freedom at interface nodes so that the kinematic continuity conditions are satisfied by conventional finite element assembly techniques. Results comparing our numerical method with an independent, analytic solution for the problem of Couette flow over rigid and deformable porous biphasic layers show that the finite element code accurately predicts the viscous fluid flows and deformation in the porous biphasic region. Thus, the analysis can be used to model the interface between synovial fluid and articular cartilage in diarthrodial joints. This is an important step toward modeling and understanding the mechanisms of joint lubrication and another step toward fully modeling the in vivo behavior of a diarthrodial joint.

  13. Th1/Th17/Th22 immune response and their association with joint pain, imagenological bone loss, RANKL expression and osteoclast activity in temporomandibular joint osteoarthritis: A preliminary report.

    PubMed

    Monasterio, G; Castillo, F; Rojas, L; Cafferata, E A; Alvarez, C; Carvajal, P; Núñez, C; Flores, G; Díaz, W; Vernal, R

    2018-05-15

    It is well accepted that the presence of cytokines belonging to the Th1/Th17/Th22 axis of immuno-inflammatory response in the joint environment, such as IL-1β, IL-17 and IL-22, respectively, are associated with pathogenesis of several synovial joint degenerative disorders. During temporomandibular joint osteoarthritis (TMJ-OA), IL-1β and IL-17 have been implicated in the inflammation and resorption of sub-chondral bone; however, the role of Th22 response in the TMJ-OA pathophysiology has not been established. This study aimed to compare the expression of Th1/Th17/Th22-type cytokines, chemokines and chemokine receptors in synovial fluid samples obtained from TMJ-OA or disk displacement with reduction (DDWR) patients. In addition, it aimed to associate these levels with joint pain, imagenological signs of bone degeneration, RANKL production, osteoclastogenesis and osteoclast-induced bone resorption. Higher levels of IL-1β, IL-17 and IL-22 were expressed in TMJ-OA compared with DDWR subjects, and these increased levels significantly correlated with RANKL expression, joint pain and articular bone degeneration. Higher levels of CCR5, CCR6 and CCR7, as well as their respective ligands CCL5 and CCL20, responsible for recruitment of IL-1β, IL-17 and IL-22-producing cells, were over-expressed in TMJ-OA compared with DDWR subjects. Osteoclastogenesis and osteoclast-induced bone resorption were significantly greater in presence of synovial fluid from TMJ-OA compared with DDWR subjects. These data demonstrate that cytokines, CCLs and CCRs associated with the Th1/Th17/Th22 axis of immuno-inflammatory response are involved in TMJ-OA pathogenesis. These findings suggest that IL-22 is involved in the RANKL expression in TMJ-OA, which in turn induces differentiation of osteoclasts and subsequent resorption of sub-chondral bone. © 2018 John Wiley & Sons Ltd.

  14. Factors determining the level and changes in intra-articular pressure in the knee joint of the dog.

    PubMed Central

    Nade, S; Newbold, P J

    1983-01-01

    Intra-articular pressure levels were determined for joint positions throughout the normal physiological range of movement of dogs' knee joints. Change in joint position resulted in change in intra-articular pressure. It was demonstrated that intra-articular pressure is highest with the joint in the fully flexed position. Minimum pressure was recorded at a position between 80 degrees and 120 degrees. Minimum pressures were usually subatmospheric. The rate of change of joint position affected intra-articular pressure. The relationship of intra-articular pressure and joint position before and after full flexion demonstrated a hysteresis effect; the pressures were lower than for the same joint position before flexion. Maintenance of the joint in the fully flexed position for increasing periods of time between repeated movement cycles resulted in a similar reduction, of constant magnitude, in pressure between joint positions before and after each period of flexion. However, there was also a progressive decrease in pressure for all joint angles over the total number of movement cycles. There is a contribution to intra-articular pressure of joint capsular compliance and fluid movement into and out of the joint (both of which are time-dependent). The recording of intra-articular pressure in conscious, upright dogs revealed similar pressure levels to those measured in anaesthetized supine dogs. The major determinants of intra-articular pressure in normal dog knee joints include joint size, synovial fluid volume, position of joint, peri-articular tissue and joint anatomy, membrane permeability, capsular compliance, and movement of fluid into and out of the joint. Images Fig. 1 PMID:6875957

  15. Increased levels of the 14-3-3 η and γ proteins in the synovial fluid of dogs with unilateral cranial cruciate ligament rupture.

    PubMed

    Sardari, Kamran; Chavez-Muñoz, Claudia; Kilani, Ruhangiz T; Schiller, Terri; Ghahary, Aziz

    2011-10-01

    The present study investigated whether the 14-3-3 η and γ proteins, which are potent matrix metalloprotease (MMP) stimulators, are detectable in the synovial fluid of dogs with cranial cruciate ligament rupture (CCLR). Synovial fluid samples from 7 dogs with unilateral CCLR and control samples from 4 dogs without a history of any joint inflammation or any other abnormalities underwent Western blot analysis for the 14-3-3 η, γ, and σ proteins as well as MMP-1 and MMP-3. Craniocaudal and lateral radiographic projections of the stifle joint were evaluated for the presence and severity of 13 specific radiographic markers of osteoarthritis and graded numerically. The Spearman method was used to detect any correlation between the 14-3-3-η level in the synovial fluid and the radiograph-based grade. The η isoform was present only in the samples from the dogs with CCLR. The levels of 14-3-3-γ, MMP-1, and MMP-3 were significantly higher in the samples from the dogs with CCLR than in the control samples (P < 0.05). However, there was no significant difference between the CCLR and control samples in the level of the σ isoform. The Spearman method showed a significant correlation between the 14-3-3-η level in the synovial fluid and the presence of either patellar osteophytes or lateral or medial (or both) condylar periarticular osteophytes (P < 0.05). The MMP stimulatory effect of the 14-3-3 η and γ isoforms may be the reason for the high levels of MMP-1 and MMP-3 observed. Thus, 14-3-3 proteins, especially the η isoform, may be important markers of osteoarthritis caused by CCLR.

  16. Increased levels of the 14-3-3 η and γ proteins in the synovial fluid of dogs with unilateral cranial cruciate ligament rupture

    PubMed Central

    Sardari, Kamran; Chavez-Muñoz, Claudia; Kilani, Ruhangiz T.; Schiller, Terri; Ghahary, Aziz

    2011-01-01

    The present study investigated whether the 14-3-3 η and γ proteins, which are potent matrix metalloprotease (MMP) stimulators, are detectable in the synovial fluid of dogs with cranial cruciate ligament rupture (CCLR). Synovial fluid samples from 7 dogs with unilateral CCLR and control samples from 4 dogs without a history of any joint inflammation or any other abnormalities underwent Western blot analysis for the 14-3-3 η, γ, and σ proteins as well as MMP-1 and MMP-3. Craniocaudal and lateral radiographic projections of the stifle joint were evaluated for the presence and severity of 13 specific radiographic markers of osteoarthritis and graded numerically. The Spearman method was used to detect any correlation between the 14-3-3-η level in the synovial fluid and the radiograph-based grade. The η isoform was present only in the samples from the dogs with CCLR. The levels of 14-3-3-γ, MMP-1, and MMP-3 were significantly higher in the samples from the dogs with CCLR than in the control samples (P < 0.05). However, there was no significant difference between the CCLR and control samples in the level of the σ isoform. The Spearman method showed a significant correlation between the 14-3-3-η level in the synovial fluid and the presence of either patellar osteophytes or lateral or medial (or both) condylar periarticular osteophytes (P < 0.05). The MMP stimulatory effect of the 14-3-3 η and γ isoforms may be the reason for the high levels of MMP-1 and MMP-3 observed. Thus, 14-3-3 proteins, especially the η isoform, may be important markers of osteoarthritis caused by CCLR. PMID:22468024

  17. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study.

    PubMed

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda

    2018-01-01

    Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.

  18. Clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis: 13 cases (2004-2012).

    PubMed

    Shaughnessy, Magen L; Sample, Susannah J; Abicht, Carter; Heaton, Caitlin; Muir, Peter

    2016-11-15

    OBJECTIVE To evaluate the clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis (IMPA). DESIGN Retrospective case series. ANIMALS 13 dogs with erosive IMPA and 66 dogs with nonerosive IMPA. PROCEDURES The medical record database of a veterinary teaching hospital was reviewed to identify dogs with IMPA that were examined between October 2004 and December 2012. For each IMPA-affected dog, information extracted from the medical record included signalment, diagnostic test results, radiographic findings, and treatments administered. Dogs were classified as having erosive IMPA if review of radiographs revealed the presence of bone lysis in multiple joints, and descriptive data were generated for those dogs. All available direct smears of synovial fluid samples underwent cytologic evaluation. The synovial fluid total nucleated cell count and WBC differential count were estimated and compared between dogs with erosive IMPA and dogs with nonerosive IMPA. RESULTS 13 of 79 (16%) dogs had erosive IMPA. Dogs with erosive IMPA had a mean ± SD age of 7.1 ± 2.4 years and body weight of 8.3 ± 3.4 kg (18.3 ± 7.5 lb). All 13 dogs had erosive lesions in their carpal joints. The estimated median synovial fluid lymphocyte count for dogs with erosive IMPA was significantly greater than that for dogs with nonerosive IMPA. All dogs received immunosuppressive therapy with leflunomide (n = 9), prednisone (3), or prednisone-azathioprine (1). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated erosive IMPA most commonly affected the carpal joints of middle-aged small-breed dogs. Further genetic analyses and analysis of lymphocyte-subsets are warranted for dogs with erosive IMPA.

  19. Comparison of fluid-fluid interfacial areas measured with X-ray microtomography and interfacial partitioning tracer tests for the same samples: COMPARISON OF FLUID-FLUID INTERFACIAL AREAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, Kieran; Carroll, Kenneth C.; Brusseau, Mark L.

    2016-07-01

    Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure nonwetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of themore » tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.« less

  20. Comparison of sample preparation techniques and data analysis for the LC-MS/MS-based identification of proteins in human follicular fluid.

    PubMed

    Lehmann, Roland; Schmidt, André; Pastuschek, Jana; Müller, Mario M; Fritzsche, Andreas; Dieterle, Stefan; Greb, Robert R; Markert, Udo R; Slevogt, Hortense

    2018-06-25

    The proteomic analysis of complex body fluids by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis requires the selection of suitable sample preparation techniques and optimal parameter settings in data analysis software packages to obtain reliable results. Proteomic analysis of follicular fluid, as a representative of a complex body fluid similar to serum or plasma, is difficult as it contains a vast amount of high abundant proteins and a variety of proteins with different concentrations. However, the accessibility of this complex body fluid for LC-MS/MS analysis is an opportunity to gain insights into the status, the composition of fertility-relevant proteins including immunological factors or for the discovery of new diagnostic and prognostic markers for, for example, the treatment of infertility. In this study, we compared different sample preparation methods (FASP, eFASP and in-solution digestion) and three different data analysis software packages (Proteome Discoverer with SEQUEST, Mascot and MaxQuant with Andromeda) combined with semi- and full-tryptic databank search options to obtain a maximum coverage of the follicular fluid proteome. We found that the most comprehensive proteome coverage is achieved by the eFASP sample preparation method using SDS in the initial denaturing step and the SEQUEST-based semi-tryptic data analysis. In conclusion, we have developed a fractionation-free methodical workflow for in depth LC-MS/MS-based analysis for the standardized investigation of human follicle fluid as an important representative of a complex body fluid. Taken together, we were able to identify a total of 1392 proteins in follicular fluid. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  2. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    USGS Publications Warehouse

    Freifeild, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-01-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  3. The U-tube: A novel system for acquiring borehole fluid samples from a deep geologic CO2 sequestration experiment

    NASA Astrophysics Data System (ADS)

    Freifeld, Barry M.; Trautz, Robert C.; Kharaka, Yousif K.; Phelps, Tommy J.; Myer, Larry R.; Hovorka, Susan D.; Collins, Daniel J.

    2005-10-01

    A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase fluid (supercritical CO2 and brine) fluid from 1.5 km depth. The data sets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydrogeochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas analysis for perfluorocarbon and noble gas tracers that were injected along with the CO2. The U-tube successfully acquired frequent samples, facilitating accurate delineation of the arrival of the CO2 plume, and on-site analysis revealed rapid changes in geochemical conditions.

  4. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  5. Prosthetic joint infection caused by Trueperella bernardiae.

    PubMed

    Gilarranz, Raul; Chamizo, Francisco; Horcajada, Iballa; Bordes-Benítez, Ana

    2016-09-01

    Trueperella bernardiae is a Gram-positive coryneform bacilli which role as human pathogen is unknown because it has been usually considered a contaminant. Furthermore its identification by biochemical test was difficult. We describe a prosthetic joint infection in a women who years ago underwent a total knee replacement with superinfection and necrosis of the patellar tendon as major complications. In the sample of synovial fluid collected grew a gram-positive bacilli which was identified by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) as T. bernardiae. The patient was treated with ciprofloxacin and currently preserves the prosthesis without signs of infection. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  6. Utility of Cytospin and Cell block Technology in Evaluation of Body Fluids and Urine Samples: A Comparative Study

    PubMed Central

    Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda

    2018-01-01

    Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653

  7. Clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis: 13 cases (2004–2012)

    PubMed Central

    Shaughnessy, Magen L.; Sample, Susannah J.; Abicht, Carter; Heaton, Caitlin; Muir, Peter

    2017-01-01

    OBJECTIVE To evaluate the clinical features and pathological joint changes in dogs with erosive immune-mediated polyarthritis (IMPA). DESIGN Retrospective case series. ANIMALS 13 dogs with erosive IMPA and 66 dogs with nonerosive IMPA. PROCEDURES The medical record database of a veterinary teaching hospital was reviewed to identify dogs with IMPA that were examined between October 2004 and December 2012. For each IMPA-affected dog, information extracted from the medical record included signalment, diagnostic test results, radiographic findings, and treatments administered. Dogs were classified as having erosive IMPA if review of radiographs revealed the presence of bone lysis in multiple joints, and descriptive data were generated for those dogs. All available direct smears of synovial fluid samples underwent cytologic evaluation. The synovial fluid total nucleated cell count and WBC differential were estimated and compared between dogs with erosive IMPA and dogs with nonerosive IMPA. RESULTS 13 of 79 (16%) dogs had erosive IMPA. Dogs with erosive IMPA had a mean ± SD age of 7.1 ± 2.4 years and bodyweight of 8.3 ± 3.4 kg (18.3 ± 7.5 lb). All 13 dogs had erosive lesions in their carpal joints. The estimated median synovial fluid lymphocyte count for dogs with erosive IMPA was significantly greater than that for dogs with nonerosive IMPA. All dogs received immunosuppressive therapy with leflunomide (n = 9), prednisone (3), or prednisone-azathioprine (1). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated erosive IMPA most commonly affected the carpal joints of middle-aged small-breed dogs. Further genetic analyses and analysis of lymphocyte-subsets is warranted for dogs with erosive IMPA. Word count = 256 PMID:27823373

  8. Predictive value of synovial fluid analysis in estimating the efficacy of intra-articular corticosteroid injections in patients with rheumatoid arthritis.

    PubMed Central

    Luukkainen, R; Hakala, M; Sajanti, E; Huhtala, H; Yli-Kerttula, U; Hämeenkorpi, R

    1992-01-01

    The predictive relevance of synovial fluid analysis and some other variables for the efficacy of intra-articular corticosteroid injections in 30 patients with rheumatoid arthritis and hydropsy in a knee joint was evaluated in a prospective study. At the onset of the study, the knee joints were aspirated and 30 mg triamcinolone hexacetonide injected intra-articularly. The circumferences and the tenderness scores of the knee joints were measured at onset, after two months, and at the end of the six months' follow up. Of the variables studied, synovial fluid C4, percentage of synovial fluid polymorphonuclear leucocytes, blood haemoglobin, and serum C3 correlated significantly with the decrease in knee joint circumference after two months, whereas only the percentage of synovial fluid polymorphonuclear leucocytes correlated significantly after six months. Between the patients with and without improvement in the tenderness scores of the knee joints, only serum IgM differed at the examination after two months; this was higher in patients whose scores showed no improvement. PMID:1632661

  9. Supercritical fluid chromatography with photodiode array detection for pesticide analysis in papaya and avocado samples.

    PubMed

    Pano-Farias, Norma S; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Jurado, José M; Muñiz-Valencia, Roberto

    2015-04-01

    To improve the analysis of pesticides in complex food matrices with economic importance, alternative chromatographic techniques, such as supercritical fluid chromatography, can be used. Supercritical fluid chromatography has barely been applied for pesticide analysis in food matrices. In this paper, an analytical method using supercritical fluid chromatography coupled to a photodiode array detection has been established for the first time for the quantification of pesticides in papaya and avocado. The extraction of methyl parathion, atrazine, ametryn, carbofuran, and carbaryl was performed through the quick, easy, cheap, effective, rugged, and safe methodology. The method was validated using papaya and avocado samples. For papaya, the correlation coefficient values were higher than 0.99; limits of detection and quantification ranged from 130-380 and 220-640 μg/kg, respectively; recovery values ranged from 72.8-94.6%; precision was lower than 3%. For avocado, limit of detection values were ˂450 μg/kg; precision was lower than 11%; recoveries ranged from 50.0-94.2%. Method feasibility was tested for lime, banana, mango, and melon samples. Our results demonstrate that the proposed method is applicable to methyl parathion, atrazine, ametryn, and carbaryl, toxics pesticides used worldwide. The methodology presented in this work could be applicable to other fruits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Weld joint concepts for on-orbit repair of Space Station Freedom fluid system tube assemblies

    NASA Technical Reports Server (NTRS)

    Jolly, Steven D.

    1993-01-01

    Because Space Station Freedom (SSF) is an independent satellite, not depending upon another spacecraft for power, attitude control, or thermal regulation, it has a variety of tubular, fluid-carrying assemblies on-board. The systems of interest in this analysis provide breathing air (oxygen and nitrogen), a working fluid (two-phase anhydrous ammonia) for thermal control, and a monopropellant (hydrazine) for station reboost. The tube assemblies run both internally and externally with respect to the habitats. They are found in up to 50 ft. continuous lengths constructed of mostly AISI 316L stainless steel tubing, but also including some Inconel 625 nickel-iron and Monel 400 nickel-copper alloy tubing. The outer diameters (OD) of the tubes range from 0.25-1.25 inches, and the wall thickness between 0.028-.095 inches. The system operational pressures range from 377 psi (for the thermal control system) to 3400 psi (for the high pressure oxygen and nitrogen supply lines in the ECLSS). SSF is designed for a fifteen to thirty year mission. It is likely that the tubular assemblies (TA's) will sustain damage or fail during this lifetime such that they require repair or replacement. The nature of the damage will be combinations of punctures, chips, scratches, and creases and may be cosmetic or actually leaking. The causes of these hypothetical problems are postulated to be: (1) faulty or fatigued fluid joints--both QD's and butt-welds; (2) micro-meteoroid impacts; (3) collison with another man-made object; and (4) over-pressure strain or burst (system origin). While the current NASA baseline may be to temporarily patch the lines by clamping metal c-sections over the defect, and then perform high pressure injection of a sealing compound, it is clear that permanent repair of the line(s) is necessary. This permanent repair could be to replace the entire TA in the segment, or perhaps the segment itself, both alternatives being extremely expensive and risky. The former would likely

  11. Examination of body fluids.

    PubMed

    Feldman, B F; Ruehl, W W

    1984-04-01

    In dogs, the pericardial sac contains about 0.3 ml, and the pleural and peritoneal cavities 0-15 ml of clear, straw-colored fluid of pH 7.4, specific gravity 1.016, protein content less than 3.0 g/dl and cell count less than 3000/microliter. Fat can be cleared from chylous fluid with NaOH and ether. Inflammation is indicated by a cell count greater than 3000/microliter. Amylase levels in peritoneal fluid are elevated in necrotizing pancreatitis. The percentage of polymorphonuclear WBC exceeds 50% in bacterial inflammations. Normal joints contain less than 1 ml highly viscid, clear or straw-colored synovial fluid with less than 1000 nucleated cells/microliter. Synovial fluid becomes flocculent and less viscid in septic and occasionally in immune-mediated arthritis, often with cell counts greater than 75,000/microliter, with 75-90% polymorphonuclear WBC. Cerebrospinal fluid is normally acellular, clear and colorless but may be red, yellow or brown with intracranial hematomas. Viral or aseptic meningitis is characterized by mononuclear cell counts of less than 500/microliter. In acute bacterial meningitis, nucleated cell counts are greater than 1000/microliter, with most being polymorphonuclear WBC. Gram staining of cerebrospinal fluid is not useful.

  12. Evaluation of Serum Cytokines in Cats with and without Degenerative Joint Disease and Associated Pain

    PubMed Central

    Gruen, Margaret E.; Messenger, Kristen M.; Thomson, Andrea E.; Griffith, Emily H.; Aldrich, Lauren A.; Vaden, Shelly; Lascelles, BDX

    2017-01-01

    Degenerative joint disease is common in cats, with signs of pain frequently found on orthopedic examination and radiographs often showing evidence of disease. However, understanding of the pathophysiology of degenerative joint disease and associated pain remains limited. Several cytokines have been identified as having a role in pain in humans, but this has not been investigated in cats. The present study was performed to use a multiplex platform to evaluate the concentration of 19 cytokines and chemokines in serum samples obtained from cats with and without degenerative joint disease and associated pain. Samples from a total of 186 cats were analyzed, with cats representing a range of severity on radiographic and orthopedic evaluations and categorized by degenerative joint disease scores and pain scores. Results showed that cats with higher radiographic degenerative joint disease scores have higher serum concentrations of IL-4 and IL-8, while cats with higher orthopedic exam pain scores have higher concentrations of IL-8, IL-2, and TNF-α increased concentration of IL-8 in degenerative joint disease and pain may be confounded by the association with age. Discriminant analysis was unable to identify one or more cytokines that distinguish between groups of cats classified based on degenerative joint disease score category or pain score category. Finally, cluster analysis driven by analyte concentrations show separation of groups of cats, but features defining the groups remain unknown. Further studies are warranted to investigate any changes in cytokine concentrations in response to analgesic therapies, and further evaluate the elevations in cytokine concentrations found here, particularly focused on studies of local cytokines present in synovial fluid. PMID:28063477

  13. A Case Report of an Acromioclavicular Joint Ganglion Associated with a Rotator Cuff Tear.

    PubMed

    Tanaka, Suguru; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2017-04-13

    We report a case of subcutaneous ganglion adjacent to the acromioclavicular joint with massive rotator cuff tear [1-7]. An 81-year-old woman presented with a ganglion adjacent to the acromioclavicular joint that had first been identified 9 months earlier. The ganglion had recurred after having been aspirated by her local physician, so she was referred to our hospital. The puncture fluid was yellowish, clear and viscous. Magnetic resonance imaging identified a massive rotator cuff tear with multi- lobular cystic lesions continuous to the acromioclavicular joint, presenting the "geyser sign". During arthroscopy, distal clavicular resection and excision of the ganglion were performed together with joint debridement. At present, the ganglion has not recurred and the patient has returned to normal daily activity. In this case, the ganglion may have developed subsequent to the concomitant massive cuff tear, due to subcutaneous fluid flow through the damaged acromioclavicular joint.

  14. Disposition of isoflupredone acetate in plasma, urine and synovial fluid following intra-articular administration to exercised Thoroughbred horses.

    PubMed

    Knych, Heather K; Harrison, Linda M; White, Alexandria; McKemie, Daniel S

    2016-01-01

    The use of isoflupredone acetate in performance horses and the scarcity of published pharmacokinetic data necessitate further study. The objective of the current study was to describe the plasma pharmacokinetics of isoflupredone acetate as well as time-related urine and synovial fluid concentrations following intra-articular administration to horses. Twelve racing-fit adult Thoroughbred horses received a single intra-articular administration (8 mg) of isoflupredone acetate into the right antebrachiocarpal joint. Blood, urine and synovial fluid samples were collected prior to and at various times up to 28 days post drug administration. All samples were analyzed using liquid chromatography-Mass Spectrometry. Plasma data were analyzed using a population pharmacokinetic compartmental model. Maximum measured plasma isoflupredone concentrations were 1.76 ± 0.526 ng/mL at 4.0 ± 1.31 h and 1.63 ± 0.243 ng/mL at 4.75 ± 0.5 h, respectively, for horses that had synovial fluid collected and for those that did not. The plasma beta half-life was 24.2 h. Isoflupredone concentrations were below the limit of detection in all horses by 48 h and 7 days in plasma and urine, respectively. Isoflupredone was detected in the right antebrachiocarpal and middle carpal joints for 8.38 ± 5.21 and 2.38 ± 0.52 days, respectively. Results of this study provide information that can be used to regulate the use of intra-articular isoflupredone in the horse. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Evaluation of a collagenase generated osteoarthritis biomarker in the synovial fluid from elbow joints of dogs with medial coronoid disease and unaffected dogs.

    PubMed

    Prink, Adam; Hayashi, Kei; Kim, Sun-Young; Kim, James; Kapatkin, Amy

    2010-01-01

    To evaluate whether synovial fluid concentrations of an osteoarthritis biomarker in dysplastic canine elbows with medial coronoid disease (MCD) are elevated compared with unaffected elbows and to determine if these concentrations correlate to the degree of articular cartilage damage. Cross sectional clinical study. Dogs (n=19; 35 elbows) with MCD and dogs (8; 16 elbows) with unaffected elbows. Concentrations of a collagenase-generated cleavage neoepitope of type II collagen (Col2-3/4C(long mono), or C2C) in joint fluid from elbows were analyzed and compared between dogs with MCD and unaffected dogs. Correlation of C2C concentration with subjective grading of articular cartilage surface damage was also evaluated. Mean (+/-SD) C2C concentration from MCD dogs was significantly higher (112.3+/-24.8 ng/mL) than in unaffected dogs (76.1+/-16.9 ng/mL; P<.05). There was a moderate correlation between cartilage damage grade and increasing C2C concentrations (P<.05, r=0.62) C2C concentrations are elevated in the synovial fluid of dogs with MCD compared with unaffected elbows, and a moderate, significant correlation was identified between these concentrations and subjective grading of articular cartilage damage. This preliminary data suggest that C2C concentrations in synovial fluid may have potential as a biomarker for diagnosis of articular cartilage damage associated with MCD and as a means of objectively determining the degree of articular cartilage damage.

  16. Fluid-inclusion data on samples from Creede, Colorado, in relation to mineral paragenesis

    USGS Publications Warehouse

    Woods, T.L.; Roedder, Edwin; Bethke, P.M.

    1982-01-01

    of Th for some quartz samples (mostly D-stage) are believed to be a result of the trapping of both gas and liquid from a boiling fluid in the upper levels of the vein system. Boiling of fluids depositing D-stage quartz is indicated by the presence of steam inclusions in quartz and the extreme variability of Th values measured on quartz. The pressure was low (< 125 kg/cm 2) throughout ore deposition. Three major growth zones in D-stage sphalerite are recognized throughout the OH vein. Deposition of the first major zone began from fluids having intermediate salinities and temperatures (7.8-9.2 wt. % eq., 240?C) but the characteristics of the fluids oscillated after that, ranging from 7.2 to 10.1 wt. % eq. and from 225?C to 270?C. Deposition of the second major, most Fe-rich zone began with the hottest, most saline fluids present during D-stage mineralization (. 270?C, 10.5-12.5 wt. % eq., 3 mole % FeS in sphalerite). The fluid then oscillated with respect to Th and salinity (213-274?C, 5.2-12.5 wt. % eq.) but showed a general decrease in both with time. Deposition of the youngest major zone began with a very Fe-poor sphalerite (0.25-0.75 mole % FeS), from the least saline, coolest fluids (5-6.5 wt. % eq., 200-212?C) and ended with a trend of increasing temperature at approximately constant salinity. The fluid-inclusion data can best be explained by a mixing model involving at least two fluids--one hot and saline, the other cool and fresher. Sudden changes in the mixing ratio, presumably from changes in the plumbing, punctuated long periods of remarkably uniform conditions of ore fluid flow and deposition. The effects of other processes such as convection and heat exchange with wall rocks must have been superimposed on this simple mixing model, however. In contrast to an earlier interpretation, several aspects of the inclusion data may be interpreted to suggest exceedingly slow ore deposition. Work in progress may resolve some of these ambiguities and refine

  17. Sampling device for withdrawing a representative sample from single and multi-phase flows

    DOEpatents

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  18. Oral splint for temporomandibular joint disorders with revolutionary fluid system

    PubMed Central

    Srivastava, Rahul; Jyoti, Bhuvan; Devi, Parvathi

    2013-01-01

    Temporomandibular joint (TMJ) diseases and disorders refer to a complex and poorly understood set of conditions, manifested by pain in the area of the jaw and associated muscles and limitations in the ability to make the normal movements of speech, facial expression, eating, chewing, and swallowing. The conventional soft occlusal splint therapy is a much safer and effective mode of a conservative line of therapy in comparison to the surgical therapy for temporomandibular joint disorders (TMD). The purpose of this article is to review the Aqualizer™, an hydrostatic oral splint, as accurate, effective treatment and differential diagnostic tool in TMD that allow treating the patient's pain quickly and accurately saving valuable treatment time. The review article has been prepared doing a literature review from the world-wide web and pubmed/medline. PMID:24019797

  19. Comparative Proteomic Analysis of Whole-Gut Lavage Fluid and Pancreatic Juice Reveals a Less Invasive Method of Sampling Pancreatic Secretions

    PubMed Central

    Rocker, Jana M; Tan, Marcus C; Thompson, Lee W; Contreras, Carlo M; DiPalma, Jack A; Pannell, Lewis K

    2016-01-01

    OBJECTIVES: There are currently no reliable, non-invasive screening tests for pancreatic ductal adenocarcinoma. The fluid secreted from the pancreatic ductal system (“pancreatic juice”) has been well-studied as a potential source of cancer biomarkers. However, it is invasive to collect. We recently observed that the proteomic profile of intestinal effluent from the bowel in response to administration of an oral bowel preparation solution (also known as whole-gut lavage fluid, WGLF) contains large amounts of pancreas-derived proteins. We therefore hypothesized that the proteomic profile is similar to that of pancreatic juice. In this study, we compared the proteomic profiles of 77 patients undergoing routine colonoscopy with the profiles of 19 samples of pure pancreatic juice collected during surgery. METHODS: WGLF was collected from patients undergoing routine colonoscopy, and pancreatic juice was collected from patients undergoing pancreatic surgery. Protein was isolated from both samples using an optimized method and analyzed by LC-MS/MS. Identified proteins were compared between samples and groups to determine similarity of the two fluids. We then compared our results with literature reports of pancreatic juice-based studies to determine similarity. RESULTS: We found 104 proteins in our pancreatic juice samples, of which 90% were also found in our WGLF samples. The majority (67%) of the total proteins found in the WGLF were common to pancreatic juice, with intestine-specific proteins making up a smaller proportion. CONCLUSIONS: WGLF and pancreatic juice appear to have similar proteomic profiles. This supports the notion that WGLF is a non-invasive, surrogate bio-fluid for pancreatic juice. Further studies are required to further elucidate its role in the diagnosis of pancreatic cancer. PMID:27228405

  20. Characterization and modeling of the stress and pore-fluid dependent acoustic properties of fractured porous rocks

    NASA Astrophysics Data System (ADS)

    Almrabat, Abdulhadi M.

    injection of supercritical CO 2 in Berea sandstone was modeled using a re-derived Biot-Gassmann substitution theory. In using the Biot-Gassmann substitution theory, it was found necessary to account for the changes in the pore-fluid compressibility in terms of the volumetric proportion and distribution of saline water and supercritical CO 2 in the sample pore space. This was done by using the empirical model of Brie et al. to account for the compressibility of mixtures of two-phase immiscible fluids. The combined Biot-Gassman and Brie et al. models were found to represent adequately the changes in P-wave velocity of Berea sandstone during displacement of saline water by supercritical CO2. The third experimental and modeling study addressed shear-wave splitting due to the presence of fractures in a rock mass. Tests were conducted using the high temperature and high pressure (HPHT) triaxial device on samples of Berea sandstone, containing a single induced tensile fracture running along the height of the sample. The fracture was created via a modified Brazilian Split Test loading where the edges of cylindrical samples were loaded on diametrically opposite two points by sharp guillotines. The Joint Roughness Coefficient (JRC) values of the fractured core samples were determined by profilometry and tilt test. The effect of mismatching of the fracture surfaces on shear wave splitting was investigated by applying different amounts of shear displacements to three core samples. The degree of mismatching of the fracture surfaces in the core samples was evaluated using the Joint Matching Coefficient (JMC). Shear-wave splitting, as measured by the difference in magnitudes of shear-wave velocities parallel and perpendicular to the fracture, Vs1 and Vs2 respectively, increases with increasing mismatch of the fracture surfaces and decreases with increasing effective stress, and approaches zero in the effective stress range tested. A model for the stress and JMC dependent shear

  1. A guided tour of current research in synovial joints with reference to wavelet methodology

    NASA Astrophysics Data System (ADS)

    Agarwal, Ruchi; Salimath, C. S.; Alam, Khursheed

    2017-10-01

    Main aim of this article is to provide a comprehensive overview of biomechanical aspects of synovial joints of human body. This can be considered as a part of continued research work carried out by various authors over a period of time. Almost every person once in life time has suffered from joint disease; this has triggered intensive investigation into various biomechanical aspects of synovial joints. This has also resulted into an increase of arthroplasty with introduction to various clinical trials. From last few decades new improvements and ideas for new technologies have been introduced to decrease the incidence of joint problem. In this paper a literature survey of recent advances, developments and recognition of wear and tear of human joint is presented. Wavelet method in Computational fluid dynamics (CFD) is relatively a new research field. This review aims to provide a glimpse of wavelet methodology in CFD. Wavelets methodology has played a vital role in the solution of governing equation of synovial fluid flow in the synovial joints represented by Reynolds equation and its modified version.

  2. Shape of wear particles found in human knee joints and their relationship to osteoarthritis.

    PubMed

    Kuster, M S; Podsiadlo, P; Stachowiak, G W

    1998-09-01

    To analyse and compare the shape of wear particles found in healthy and osteoarthritic human knee joints for monitoring the progress of osteoarthritis, the long-term prognosis and to evaluate therapeutic regimens. Joint particles from seven patients with normal cartilage in all compartments of the knee joint, 12 patients with fibrillation of less than half the cartilage thickness (grade 1), seven patients with fibrillation of more than half the cartilage thickness (grade 2) and four patients with erosions down to bone (grade 3) were analysed. A total of 565 particles were extracted from synovial fluid samples by ferrography and analysed in a scanning electron microscope. A number of numerical descriptors, i.e. boundary fractal dimension, shape factor, convexity and elongation, were calculated for each particle image and correlated to the degree of osteoarthritis using non-parametric tests. Experiments demonstrated that there were significant differences between the numerical descriptors calculated for wear particles from healthy and osteoarthritic knee joints (P < 0.01), suggesting that the particle shape can be used as an indicator of the joint condition. In particular, the fractal dimension of the particle boundary was shown to correlate directly with the degree of osteoarthritis. Numerical analysis of the shape of wear particles found in human knee joints may provide a reliable means for the assessment of cartilage repair after surgical or conservative treatment of osteoarthritis.

  3. Evaluation of a commercial rubella IgM assay for use on oral fluid samples for diagnosis and surveillance of congenital rubella syndrome and postnatal rubella.

    PubMed

    Vijaylakshmi, P; Muthukkaruppan, V R; Rajasundari, A; Korukluoglu, G; Nigatu, W; L A Warrener; Samuel, D; Brown, D W G

    2006-12-01

    Clinical diagnosis (surveillance) of rubella is unreliable and laboratory confirmation is essential. Detection of virus specific IgM in serum is the most commonly used method. However, the use of serum necessitates the drawing of blood, either through venipuncture or finger/heel prick, which can be difficult in young babies. Oral fluid samples have proved useful as an alternative, less invasive sample for virus specific IgM detection however until recently no commercial rubella IgM tests were available, restricting the usefulness of this approach. To evaluate the performance of the Microimmune Rubella IgM capture EIA using oral fluid samples from outbreaks as well as in cases of suspected congenital rubella syndrome (CRS). Paired serum and oral fluids were collected from cases during a rubella outbreak in three provinces in Turkey. Matched serum and oral fluid samples were collected from children with suspected CRS in an active surveillance programme at the Aravind Eye Hospital in South India. Serum samples were collected as part of the measles surveillance programme in Ethiopia. On serum samples the sensitivity and specificity of the Microimmune Rubella IgM capture EIA compared to Behring Enzygnost rubella IgM test was 96.9% (62/64; 95% CI 94.2-100%) and 100% (53/53; 95% CI 93.2-100%). On oral fluids compared to matched Behring results on serum the sensitivity was 95.5% (42/44; 95% CI 84.5-99.4%). The sensitivity and specificity of Microimmune Rubella IgM capture EIA on oral fluids from suspected CRS cases compared to serum results using Behring Enzygnost IgM assay was 100% (95% CI 84.5-100%) and 100% (95% CI 95.8-100.0%) respectively. Microimmune Rubella IgM capture EIA has adequate performance for diagnosis and surveillance of rubella in outbreak using either serum or oral fluid specimens.

  4. Relationship between automated total nucleated cell count and enumeration of cells on direct smears of canine synovial fluid.

    PubMed

    Dusick, Allison; Young, Karen M; Muir, Peter

    2014-12-01

    Canine osteoarthritis is a common disorder seen in veterinary clinical practice and causes considerable morbidity in dogs as they age. Synovial fluid analysis is an important tool for diagnosis and treatment of canine joint disease and obtaining a total nucleated cell count (TNCC) is particularly important. However, the low sample volumes obtained during arthrocentesis are often insufficient for performing an automated TNCC, thereby limiting diagnostic interpretation. The aim of the present study was to investigate whether estimation of TNCC in canine synovial fluid could be achieved by performing manual cell counts on direct smears of fluid. Fifty-eight synovial fluid samples, taken by arthrocentesis from 48 dogs, were included in the study. Direct smears of synovial fluid were prepared, and hyaluronidase added before cell counts were obtained using a commercial laser-based instrument. A protocol was established to count nucleated cells in a specific region of the smear, using a serpentine counting pattern; the mean number of nucleated cells per 400 × field was then calculated. There was a positive correlation between the automated TNCC and mean manual cell count, with more variability at higher TNCC. Regression analysis was performed to estimate TNCC from manual counts. By this method, 78% of the samples were correctly predicted to fall into one of three categories (within the reference interval, mildly to moderately increased, or markedly increased) relative to the automated TNCC. Intra-observer and inter-observer agreement was good to excellent. The results of the study suggest that interpretation of canine synovial fluid samples of low volume can be aided by methodical manual counting of cells on direct smears. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Clinical and radiographic study of bone and joint lesions in 26 dogs with leishmaniasis.

    PubMed

    Agut, A; Corzo, N; Murciano, J; Laredo, F G; Soler, M

    2003-11-22

    Twenty-six dogs with parasitologically confirmed leishmaniasis and abnormalities of gait were studied to determine the most common radiological patterns of bone and joint lesions. The clinical findings included either lameness, joint pain and crepitation, soft tissue swelling and/or muscle atrophy. Bone lesions were observed radiographically in 12 of the 26 dogs; the radius and ulna were affected in seven, the tibia in six and the femur in six. Joint lesions were observed radiographically in 15 of the 26 dogs; the carpus and stifle were affected in all 15, and the tarsus in nine. There was a tendency for the bones and joints to be affected bilaterally. The radiographic patterns observed were different in the long bones and the joints. In the long bones, the most common pattern was periosteal and intramedullary proliferation, involving the diaphyses and related to the nutrient foramen; in the joints, two patterns, either non-erosive or erosive polyarthritis with soft-tissue swelling, were observed. The changes observed in the synovial fluid were associated in most cases with osteolytic lesions. However, Leishmania organisms were identified in the synovial fluid from joints without bony radiographic changes.

  6. A Simple Joint Estimation Method of Residual Frequency Offset and Sampling Frequency Offset for DVB Systems

    NASA Astrophysics Data System (ADS)

    Kwon, Ki-Won; Cho, Yongsoo

    This letter presents a simple joint estimation method for residual frequency offset (RFO) and sampling frequency offset (STO) in OFDM-based digital video broadcasting (DVB) systems. The proposed method selects a continual pilot (CP) subset from an unsymmetrically and non-uniformly distributed CP set to obtain an unbiased estimator. Simulation results show that the proposed method using a properly selected CP subset is unbiased and performs robustly.

  7. Management of Candida guilliermondii joint infection in a dog.

    PubMed

    Bufalari, Antonello; Maggio, Chiara; Moretti, Giulia; Crovace, Alberto; Stefanetti, Valentina; Straubinger, Reinhard Konrad; Passamonti, Fabrizio

    2016-07-08

    Candida spp. are dimorphic fungi in the family Cryptococcaceae. Infections with Candida spp. are usually rare conditions in dogs, but immunocompromised patients have a higher risk for developing invasive candidal infections. A 5-year-old male Boxer, positive to Leishmania infantum, was referred to the Veterinary Teaching Hospital of the Department of Veterinary Medicine, University of Perugia, Italy for examination of a non-weight bearing left hind limb lameness of a duration of at least 3 months. During this period, treatment involved systemic anti-inflammatory medications and intra-articular corticosteroid administration. On presentation, clinical examination and radiographic findings were suggestive of cranial cruciate ligament deficiency. To support this diagnosis a stifle arthroscopy was performed: it confirmed a partial rupture of cranial cruciate ligament. Samples culture of synovial fluid and membrane was routinely collected as well, and revealed Candida guilliermondii joint infection. Treatment for the C. guilliermondii joint infection involved systemic anti-fungal therapy, joint lavage and intra-articular administration of antifungal drugs. Lameness improved markedly during this treatment, but lameness did not resolve completely, probably due to cranial cruciate ligament deficiency. Tibial tuberosity advancement (TTA) was chosen in order to treat stifle instability and was performed 4 weeks following cessation of treatment of the C. guilliermondii joint infection. Six month after TTA the dog showed a completely recovery with no lameness. To the authors' knowledge, this is the first case of Candida spp. joint infection reported in dogs. The cause of the progression of the joint C. guilliermondii infection remains unclear but it may be associated with leishmaniasis or intra-articular corticosteroid injections. Treatment with systemic and intra-articular anti-fungal therapies was successful. In the evaluation of hind limb lameness in a chronically

  8. Serum and synovial fluid cytokine profiling in hip osteoarthritis: distinct from knee osteoarthritis and correlated with pain.

    PubMed

    Ren, Guomin; Lutz, Ian; Railton, Pamela; Wiley, J Preston; McAllister, Jenelle; Powell, James; Krawetz, Roman J

    2018-02-05

    Inflammation is associated with the onset and progression of osteoarthritis in multiple joints. It is well known that mechanical properties differ between different joints, however, it remains unknown if the inflammatory process is similar/distinct in patients with hip vs. knee OA. Without complete understanding of the role of any specific cytokine in the inflammatory process, understanding the 'profile' of inflammation in a given patient population is an essential starting point. The aim of this study was to identify serum cytokine profiles in hip Osteoarthritis (OA), and investigate the association between cytokine concentrations and clinical measurements within this patient population and compare these findings to knee OA and healthy control cohorts. In total, 250 serum samples (100 knee OA, 50 hip OA and 100 control) and 37 synovial fluid samples (8 knee OA, 14 hip OA and 15 control) were analyzed using a multiplex ELISA based approach. Synovial biopsies were also obtained and examined for specific cytokines. Pain, physical function and activity within the hip OA cohort were examined using the HOOS, SF-36, HHS and UCLA outcome measures. The three cohorts showed distinct serum cytokine profiles. EGF, FGF2, MCP3, MIP1α, and IL8 were differentially expressed between hip and knee OA cohorts; while FGF2, GRO, IL8, MCP1, and VEGF were differentially expressed between hip OA and control cohorts. Eotaxin, GRO, MCP1, MIP1β, VEGF were differentially expressed between knee OA and control cohorts. EGF, IL8, MCP1, MIP1β were differentially expressed in synovial fluid from a sub-set of patients from each cohort. Specifically within the hip OA cohort, IL-6, MDC and IP10 were associated with pain and were also found to be present in synovial fluid and synovial membrane (except IL-6) of patients with hip OA. OA may include different inflammatory subtypes according to affected joints and distinct inflammatory processes may drive OA in these joints. IL6, MDC and IP10 are

  9. Fluid permeability measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2008-02-05

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  10. Liquid-Based Medium Used to Prepare Cytological Breast Nipple Fluid Improves the Quality of Cellular Samples Automatic Collection

    PubMed Central

    Zonta, Marco Antonio; Velame, Fernanda; Gema, Samara; Filassi, Jose Roberto; Longatto-Filho, Adhemar

    2014-01-01

    Background Breast cancer is the second cause of death in women worldwide. The spontaneous breast nipple discharge may contain cells that can be analyzed for malignancy. Halo® Mamo Cyto Test (HMCT) was recently developed as an automated system indicated to aspirate cells from the breast ducts. The objective of this study was to standardize the methodology of sampling and sample preparation of nipple discharge obtained by the automated method Halo breast test and perform cytological evaluation in samples preserved in liquid medium (SurePath™). Methods We analyzed 564 nipple fluid samples, from women between 20 and 85 years old, without history of breast disease and neoplasia, no pregnancy, and without gynecologic medical history, collected by HMCT method and preserved in two different vials with solutions for transport. Results From 306 nipple fluid samples from method 1, 199 (65%) were classified as unsatisfactory (class 0), 104 (34%) samples were classified as benign findings (class II), and three (1%) were classified as undetermined to neoplastic cells (class III). From 258 samples analyzed in method 2, 127 (49%) were classified as class 0, 124 (48%) were classified as class II, and seven (2%) were classified as class III. Conclusion Our study suggests an improvement in the quality and quantity of cellular samples when the association of the two methodologies is performed, Halo breast test and the method in liquid medium. PMID:29147397

  11. Physical therapy applications of MR fluids and intelligent control

    NASA Astrophysics Data System (ADS)

    Dong, Shufang; Lu, Ke-Qian; Sun, J. Q.; Rudolph, Katherine

    2005-05-01

    Resistance exercise has been widely reported to have positive rehabilitation effects for patients with neuromuscular and orthopaedic conditions. This paper presents an optimal design of magneto-rheological fluid dampers for variable resistance exercise devices. Adaptive controls for regulating the resistive force or torque of the device as well as the joint motion are presented. The device provides both isometric and isokinetic strength training for various human joints.

  12. Expression of immune response genes in the stifle joint of dogs with oligoarthritis and degenerative cranial cruciate ligament rupture.

    PubMed

    Muir, P; Schaefer, S L; Manley, P A; Svaren, J P; Oldenhoff, W E; Hao, Z

    2007-10-15

    Dysregulation of immune responses within joints plays an important role in development of inflammatory arthritis. We determined expression of a panel of immune response and matrix turnover genes in synovial fluid collected from a group of dogs with stifle oligoarthritis and associated degenerative cranial cruciate ligament (CCL) rupture (n=27). We also studied synovial fluid gene expression in dogs affected with other forms of degenerative arthritis (n=9) and in the stifle joint of healthy dogs with intact CCL (n=14). After collection, synovial cells were pelleted and RNA was isolated. Relative expression of cathepsin K, cathepsin S, tartrate-resistant acid phosphatase (TRAP), matrix metalloproteinase-9 (MMP-9), invariant chain (li), toll-like receptor-2 (TLR-2), and TLR-9 was determined using real-time quantitative RT-PCR. Data were normalized to peripheral blood mononuclear cells (PBMC) as an internal control. Relative expression of cathepsin K, MMP-9, TRAP, and li was increased in the stifle synovial fluid of dogs with oligoarthritis, when compared with the stifles of healthy dogs (P<0.05). In contrast, relative expression of all of the genes-of-interest in synovial fluid from joints affected with other forms of arthritis was not significantly different from the stifles of healthy dogs. TRAP expression was also significantly increased in the stifle joints of dogs with oligoarthritis, when compared to joint expression of TRAP in dogs with other forms of degenerative arthritis (P<0.05). In the dogs with stifle oligoarthritis, expression of both matrix turnover and immune response genes was increased in stifle synovial fluid, when compared with the internal PBMC control, whereas in healthy dogs and dogs with other forms of arthritis, only expression of matrix turnover genes was increased in synovial fluid, when compared with the internal PBMC control (P<0.05). Taken together, these findings suggest that antigen-specific immune responses within the stifle joint may

  13. Soluble Flt-1 improves the repair of ankle joint injury in rats

    PubMed Central

    Tian, Jing; Xie, Bing; Xiang, Liangbi; Zhao, Yong; Zhou, Dapeng

    2016-01-01

    The ankle injuries create great pain to a great number of patients worldwide. Past studies have focused on the development of practical treatments to relieve pain and improve recovery, but the molecular mechanisms underlying the ankle injuries, especially the local inflammation in the damaged ankle joint, have been rarely studied. Moreover, although reduction of production and secretion of pro-inflammatory cytokines may reduce the pain and promote the recovery, a practical approach is currently lacking. Here, we detected significantly higher levels of placental growth factor (PLGF) and pro-inflammatory cytokines in the joint fluid from the patients of acute ankle joint injury (AAJI). Interestingly, the levels of PLGF and pro-inflammatory cytokines in the joint fluid strongly correlated. In order to examine whether PLGF may regulate the production and secretion of pro-inflammatory cytokines in the injured joint, we used a rat carrageenan-induced ankle injury model for AAJI in humans. We injected soluble Flt-1 (sFlt-1) into the articular cavity of the injured ankle joint to block PLGF signaling and found that injection of sFlt-1 significantly improved the rat behavior in activity wheels test, which appeared to result from reduced secretion of the pro-inflammatory cytokines in the ankle joint. Thus, our study suggests that blocking PLGF signaling may be a novel therapeutic approach for treating AAJI in humans. PMID:27904694

  14. Intra-articular pressures and joint mechanics: should we pay attention to effusion in knee osteoarthritis?

    PubMed

    Rutherford, Derek James

    2014-09-01

    What factors play a role to ensure a knee joint does what it should given the demands of moving through the physical environment? This paper aims to probe the hypothesis that intra-articular joint pressures, once a topic of interest, have been left aside in contemporary frameworks in which we now view knee joint function. The focus on ligamentous deficiencies and the chondrocentric view of osteoarthritis, while important, have left little attention to the consideration of other factors that can impair joint function across the lifespan. Dynamic knee stability is required during every step we take. While there is much known about the role that passive structures and muscular activation play in maintaining a healthy knee joint, this framework does not account for the role that intra-articular joint pressures may have in providing joint stability during motion and how these factors interact. Joint injuries invariably result in some form of intra-articular fluid accumulation. Ultimately, it may be how the knee mechanically responds to this fluid, of which pressure plays a significant role that provides the mechanisms for continued function. Do joint pressures provide an important foundation for maintaining knee function? This hypothesis is unique and argues that we are missing an important piece of the puzzle when attempting to understand implications that joint injury and disease have for joint function. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Ball assisted device for analytical surface sampling

    DOEpatents

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  16. Effect of traction on wrist joint space and cartilage visibility with and without MR arthrography

    PubMed Central

    Griffith, James F; Tang, W K; Ng, Alex W H; Yeung, David K W

    2017-01-01

    Objective: To compare the effect of traction during non-arthrographic and arthrographic MR examination of the wrist with regard to joint space width, joint fluid dispersion and cartilage surface visibility. Methods: Prospective 3-T MRI study of 100 wrists in 96 patients. The first 50 wrists underwent MR arthrography first without traction and then with traction. The following 50 wrists underwent standard MR first without traction and then with traction. On these examinations, two radiologists independently measured (i) joint space width, semi-quantitatively graded (ii) joint fluid dispersion between opposing cartilage surfaces and (iii) articular cartilage surface visibility. The three parameters were compared between the two groups. Results: Traction led to an increase in joint space width at nearly all joints in all patients (p < 0.05), although more so in the arthrography (∆ = 0.08–0.79 mm, all p < 0.05) than in the non-arthrography (∆ = 0.001–0.61 mm, all p < 0.05) group. Joint fluid dispersion and cartilage surface visibility improved after traction in nearly all joints (p < 0.05) in all patients and more so in the arthographic than in the non-arthrography group. Conclusion: Traction did significantly improve cartilage surface visibility for standard MRI of the wrist although the effect was not as great as that seen with MR arthography or MR arthrography with traction. Advances in knowledge: This is the first study to show the beneficial effect of traction during standard non-arthrography MRI of the wrist and compare the effect of traction between non-arthrographic and arthrographic MRI of the wrist. PMID:28181830

  17. Experimental cryo-irrigation of the knee joint.

    PubMed

    Chen, S C; Helal, B; Revell, P A; Brocklehurst, R; Currey, H L

    1986-10-01

    Experiments have been carried out to test the feasibility of using cryo-irrigation as a means of ablating the synovium in the rheumatoid knee joint. Cryo-irrigation was performed by a cooling machine and pump, which circulated cold 200/10 centistoke (cSt) silicone through the knee joint of rabbits anaesthetised with intravenous (IV) 'Saffan'. Fluid left the joint at -5 to -10 degrees C. Sixteen normal New Zealand rabbits received cryo-irrigation of one knee joint for 10-20 minutes and were killed at one day, and one, two, and 12 weeks thereafter. Judged by radioactive sulphate incorporation there was no impairment of chondrocyte function in the articular cartilage of irrigated joints. Histological examination showed mild synovitis and some loss of staining of superficial cartilage in 6/16 irrigated joints (v 1/16 control joints). Similar treatment of rabbit joints in which the Glynn model of synovitis had been induced showed marked reduction of synovitis 14-45 days after silicone treatment. Nine of 26 animals in which synovitis was induced in both knees and cryo-irrigation performed in one knee died either immediately postoperatively or during the next week. These deaths remain unexplained. A single dog received cryo-irrigation of one knee (-6 to -9 degrees C for 22 min) and remained perfectly well up to sacrifice at six months, when the joint appeared histologically completely normal.

  18. Fluid Inclusion Gas Analysis

    DOE Data Explorer

    Dilley, Lorie

    2013-01-01

    Fluid inclusion gas analysis for wells in various geothermal areas. Analyses used in developing fluid inclusion stratigraphy for wells and defining fluids across the geothermal fields. Each sample has mass spectrum counts for 180 chemical species.

  19. Pressure-volume relationships and elastance in the knee joint of the dog.

    PubMed

    Nade, S; Newbold, P J

    1984-12-01

    This study has investigated changes in intra-articular hydrostatic pressure in the knee joints of normal dogs in response to continuous and stepwise infusions of fluids. The relationship between pressure and volume in the joint was examined over the pressure range of -8 to +50 mmHg, and also at much higher pressures often associated with joint disease or injury. The effects of joint angle and dog weight on the pressure-volume relationship and on elastance of the dogs' knees were also examined. With liquid paraffin B.P. the pressure was found to increase more with each unit volume infused at subatmospheric pressures than at pressures around atmospheric, and increased more again at higher pressures. The pressure-volume curve with saline infusions was affected by egress of fluid from the joint at supra-atmospheric pressure. Above +5 mmHg the rise in pressure per unit volume infused was less than that for paraffin at the same volume. Elastance and compliance of the normal joint capsule were calculated from the pressure-volume data. Elastance was high at subatmospheric pressures, decreased rapidly as atmospheric pressure was approached and rose as a linear function of pressure above 12 mmHg. The biphasic shape of the elastance-pressure curve is discussed, and explanations for the shape are suggested. After intra-articular pressure in the knee was raised by infusion of paraffin oil the joint was moved through the range of positions from 125 deg extension to 50 deg flexion. Intra-articular pressure did not change across the range 125-110 deg. However, increasing the angle of flexion from 110 to 50 deg resulted in a rise in pressure which became steeper for each volume increment. Increasing intra-articular fluid volume caused a decrease in the total range of movement of the joint. The pressure-volume curves measured at extended angles of 110, 125 and 140 deg, where the starting pressures were subatmospheric, were the same. At flexed joint positions of 80 and 50 deg, where

  20. A study of fluid intake from beverages in a sample of healthy French children, adolescents and adults

    PubMed Central

    Bellisle, F; Thornton, S N; Hébel, P; Denizeau, M; Tahiri, M

    2010-01-01

    Background/Objectives: To assess the intake of fluid in healthy French children, adolescents, adults and seniors, considering amounts, types of beverages, time and place of consumption. Subjects/Methods: Data regarding fluid intake were extracted and analyzed from the National Intake Survey, which was conducted in quota samples of the French population (Comportement et Consommations Alimentaires en France study). Seven-day questionnaires were administered to free-living individuals in 2002–2003. A total of 566 children (aged 6–11 years), 333 adolescents (aged 12–19 years), 831 adults (aged 20–54 years) and 443 seniors (aged ⩾55 years) were included in this study. Results: The average total intake of fluid was 1–1.3 l per day depending on age groups. Water accounted for about one-half of daily fluid intake. The contribution of other types of beverages varied with age (for example, dairy drinks in children and adolescents; alcoholic drinks in adults and seniors). Intake of sodas (including regular and light) was highest in adolescents (169 ml a day). Beverages were mainly consumed at home during meals. Conclusions: This is the first description of fluid intake in French children, adolescents, adults and seniors, considering amounts, types of beverages, time and place of intake. It shows that water is the main source of fluid in all age groups. Selection of various types of beverages is different according to age. PMID:20160751

  1. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    PubMed

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  2. Comparison of Fluid-Fluid Interfacial Areas Measured with X-ray Microtomography and Interfacial Partitioning Tracer Tests for the same Samples.

    PubMed

    McDonald, Kieran; Carroll, Kenneth C; Brusseau, Mark L

    2016-07-01

    Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure non-wetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of the tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.

  3. Some new evidence on human joint lubrication.

    PubMed Central

    Unsworth, A; Dowson, D; Wright, V

    1975-01-01

    Theoretical consideration has been given to the use of pendulum machines which are used to examine the frictional properties of human joints by incorporating them as fulcra. As a result, a new type of pendulum machine has been built which incorporates the facility to apply sudden loads to the joint on starting the swinging motion, and also the ability to measure directly the frictional torque experienced by the joint. The results obtained from natural hip joints indicate the presence of squeeze film lubrication under conditions of sudden loading of a joint. In addition, a self-generated fluid film process was observed at low loads while at higher loads boundary lubrication appeared to be important. These results have been used to describe the lubrication regimens occurring in a normal activity such as walking. A single experiment carried out on a hip from a patient suffering from severe rheumatoid arthritis has also been reported and the frictional resistance was seen to be increased fifteenfold compared to a normal hip. Images PMID:1190847

  4. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, David R.

    1998-01-01

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis.

  5. Wide-field synovial fluid imaging using polarized lens-free on-chip microscopy for point-of-care diagnostics of gout (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Yibo; Lee, Seung Yoon; Zhang, Yun; Furst, Daniel; Fitzgerald, John; Ozcan, Aydogan

    2016-03-01

    Gout and pseudogout are forms of crystal arthropathy caused by monosodium urate (MSU) and calcium pyrophosphate dehydrate (CPPD) crystals in the joint, respectively, that can result in painful joints. Detecting the unique-shaped, birefringent MSU/CPPD crystals in a synovial fluid sample using a compensated polarizing microscope has been the gold-standard for diagnosis since the 1960's. However, this can be time-consuming and inaccurate, especially if there are only few crystals in the fluid. The high-cost and bulkiness of conventional microscopes can also be limiting for point-of-care diagnosis. Lens-free on-chip microscopy based on digital holography routinely achieves high-throughput and high-resolution imaging in a cost-effective and field-portable design. Here we demonstrate, for the first time, polarized lens-free on-chip imaging of MSU and CPPD crystals over a wide field-of-view (FOV ~ 20.5 mm2, i.e., <20-fold larger compared a typical 20X objective-lens FOV) for point-of-care diagnostics of gout and pseudogout. Circularly polarizer partially-coherent light is used to illuminate the synovial fluid sample on a glass slide, after which a quarter-wave-plate and an angle-mismatched linear polarizer are used to analyze the transmitted light. Two lens-free holograms of the MSU/CPPD sample are taken, with the sample rotated by 90°, to rule out any non-birefringent objects within the specimen. A phase-recovery algorithm is also used to improve the reconstruction quality, and digital pseudo-coloring is utilized to match the color and contrast of the lens-free image to that of a gold-standard microscope image to ease the examination by a rheumatologist or a laboratory technician, and to facilitate computerized analysis.

  6. Demonstrate a Low Biochemical Oxygen Demand Aircraft Deicing Fluid

    DTIC Science & Technology

    2013-03-01

    Technologies International, LTD for collection and recycling of fluids. Spent fluid, diluted with any water, slush or snow removed from the aircraft or...Resistance Unmated only – some failures Voltage Withstand Testing Unmated only – some failures Plastic Windows Crazing Effect Pass The testing did result...At Joint Base McGuire-Dix-Lakehurst, however, waste PG is currently collected with a vacuum truck and recycled . Factors such as the market demand

  7. Demonstrate a Low Biochemical Oxygen Demand Aircraft Deicing Fluid

    DTIC Science & Technology

    2013-03-04

    Technologies International, LTD for collection and recycling of fluids. Spent fluid, diluted with any water, slush or snow removed from the aircraft or...Resistance Unmated only – some failures Voltage Withstand Testing Unmated only – some failures Plastic Windows Crazing Effect Pass The testing did result...At Joint Base McGuire-Dix-Lakehurst, however, waste PG is currently collected with a vacuum truck and recycled . Factors such as the market demand

  8. Fluid sampling apparatus and method

    DOEpatents

    Yeamans, D.R.

    1998-02-03

    Incorporation of a bellows in a sampling syringe eliminates ingress of contaminants, permits replication of amounts and compression of multiple sample injections, and enables remote sampling for off-site analysis. 3 figs.

  9. Forensic interlaboratory evaluation of the ForFLUID kit for vaginal fluids identification.

    PubMed

    Giampaoli, Saverio; Alessandrini, Federica; Berti, Andrea; Ripani, Luigi; Choi, Ajin; Crab, Roselien; De Vittori, Elisabetta; Egyed, Balazs; Haas, Cordula; Lee, Hwan Young; Korabecná, Marie; Noel, Fabrice; Podini, Daniele; Tagliabracci, Adriano; Valentini, Alessio; Romano Spica, Vincenzo

    2014-01-01

    Identification of vaginal fluids is an important step in the process of sexual assaults confirmation. Advances in both microbiology and molecular biology defined technical approaches allowing the discrimination of body fluids. These protocols are based on the identification of specific bacterial communities by microfloraDNA (mfDNA) amplification. A multiplex real time-PCR assay (ForFLUID kit) has been developed for identifying biological fluids and for discrimination among vaginal, oral and fecal samples. In order to test its efficacy and reliability of the assay in the identification of vaginal fluids, an interlaboratory evaluation has been performed on homogeneous vaginal swabs. All the involved laboratories were able to correctly recognize all the vaginal swabs, and no false positives were identified when the assay was applied on non-vaginal samples. The assay represents an useful molecular tool that can be easily adopted by forensic geneticists involved in vaginal fluid identification. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  10. Individual differences in fluid intelligence predicts inattentional blindness in a sample of older adults: a preliminary study.

    PubMed

    O'Shea, Deirdre M; Fieo, Robert A

    2015-07-01

    Previous research has shown that aging increases susceptibility to inattentional blindness (Graham and Burke, Psychol Aging 26:162, 2011) as well as individual differences in cognitive ability related to working memory and executive functions in separate studies. Therefore, the present study was conducted in an attempt to bridge a gap that involved investigating 'age-sensitive' cognitive abilities that may predict inattentional blindness in a sample of older adults. We investigated whether individual differences in general fluid intelligence and speed of processing would predict inattentional blindness in our sample of older adults. Thirty-six healthy older adults took part in the study. Using the inattentional blindness paradigm developed by Most et al. (Psychol Rev 112:217, 2005), we investigated whether rates of inattentional blindness could be predicted by participant's performance on the Raven's Advanced Progressive Matrices and a choice-reaction time task. A Mann-Whitney U test revealed that a higher score on the Raven's Advanced Progressive Matrices was significantly associated with lower incidences of inattentional blindness. However, a t test revealed that choice-reaction times were not significantly associated with inattentional blindness. Preliminary results from the present study suggest that individual differences in general fluid intelligence are predictive of inattentional blindness in older adults but not speed of processing. Moreover, our findings are consistent with previous studies that have suggested executive attention control may be the source of these individual differences. These findings also highlight the association between attention and general fluid intelligence and how it may impact environmental awareness. Future research would benefit from repeating these analyses in a larger sample and also including a younger comparison group.

  11. Mechanisms of sampling interstitial fluid from skin using a microneedle patch.

    PubMed

    Samant, Pradnya P; Prausnitz, Mark R

    2018-05-01

    Although interstitial fluid (ISF) contains biomarkers of physiological significance and medical interest, sampling of ISF for clinical applications has made limited impact due to a lack of simple, clinically useful techniques that collect more than nanoliter volumes of ISF. This study describes experimental and theoretical analysis of ISF transport from skin using microneedle (MN) patches and demonstrates collection of >1 µL of ISF within 20 min in pig cadaver skin and living human subjects using an optimized system. MN patches containing arrays of submillimeter solid, porous, or hollow needles were used to penetrate superficial skin layers and access ISF through micropores (µpores) formed upon insertion. Experimental studies in pig skin found that ISF collection depended on transport mechanism according to the rank order diffusion < capillary action < osmosis < pressure-driven convection, under the conditions studied. These findings were in agreement with independent theoretical modeling that considered transport within skin, across the interface between skin and µpores, and within µpores to the skin surface. This analysis indicated that the rate-limiting step for ISF sampling is transport through the dermis. Based on these studies and other considerations like safety and convenience for future clinical use, we designed an MN patch prototype to sample ISF using suction as the driving force. Using this approach, we collected ISF from human volunteers and identified the presence of biomarkers in the collected ISF. In this way, sampling ISF from skin using an MN patch could enable collection of ISF for use in research and medicine.

  12. Effect of synovial fluid, phosphate-buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implants.

    PubMed

    Lewis, A C; Kilburn, M R; Papageorgiou, I; Allen, G C; Case, C P

    2005-06-15

    The corrosion and dissolution of high- and low-carbon CoCrMo alloys, as used in orthopedic joint replacements, were studied by immersing samples in phosphate-buffered saline (PBS), water, and synovial fluid at 37 degrees C for up to 35 days. Bulk properties were analyzed with a fine ion beam microscope. Surface analyses by X-ray photoelectron spectroscopy and Auger electron spectroscopy showed surprisingly that synovial fluid produced a thin oxide/hydroxide layer. Release of ions into solution from the alloy also followed an unexpected pattern where synovial fluid, of all the samples, had the highest Cr concentration but the lowest Co concentration. The presence of carbide inclusions in the alloy did not affect the corrosion or the dissolution mechanisms, although the carbides were a significant feature on the metal surface. Only one mechanism was recognized as controlling the thickness of the oxide/hydroxide interface. The analysis of the dissolved metal showed two mechanisms at work: (1) a protein film caused ligand-induced dissolution, increasing the Cr concentration in synovial fluid, and was explained by the equilibrium constants; (2) corrosion at the interface increased the Co in PBS. The effect of prepassivating the samples (ASTM F-86-01) did not always have the desired effect of reducing dissolution. The release of Cr into PBS increased after prepassivation. The metal-synovial fluid interface did not contain calcium phosphate as a deposit, typically found where samples are exposed to calcium rich bodily fluids. (c) 2005 Wiley Periodicals, Inc.

  13. Demonstration of the ExoMars sample preparation and distribution system jointly with an optical instrument head

    NASA Astrophysics Data System (ADS)

    Schulte, Wolfgang; Thiele, Hans; Hofmann, Peter; Baglioni, Pietro

    . Availability of both, the SPDS mechanisms and the Raman Spectrometer optical head at Kayser-Threde facilities allowed to demonstrate for the first time a sample preparation chain with a joint operation of the optical head. Mineral samples were crushed, dosed into sample containers on the carousel, flattened and then inspected by the Raman optical head. The samples were provided by the University of Jena, a member of the ExoMars Raman science team. This paper will give an overview of the breadboards developed so far for the ExoMars SPDS and the Raman optical head and illustrate the joint demonstration test setup of the SPDS with the instrument. The different behavior of different sample materials will be highlighted and first conclusions will be drawn on what could be learned from test setups combining the ExoMars SPDS and analytical instruments.

  14. Differentiation of five body fluids from forensic samples by expression analysis of four microRNAs using quantitative PCR.

    PubMed

    Sauer, Eva; Reinke, Ann-Kathrin; Courts, Cornelius

    2016-05-01

    Applying molecular genetic approaches for the identification of forensically relevant body fluids, which often yield crucial information for the reconstruction of a potential crime, is a current topic of forensic research. Due to their body fluid specific expression patterns and stability against degradation, microRNAs (miRNA) emerged as a promising molecular species, with a range of candidate markers published. The analysis of miRNA via quantitative Real-Time PCR, however, should be based on a relevant strategy of normalization of non-biological variances to deliver reliable and biologically meaningful results. The herein presented work is the as yet most comprehensive study of forensic body fluid identification via miRNA expression analysis based on a thoroughly validated qPCR procedure and unbiased statistical decision making to identify single source samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Offline solid phase microextraction sampling system

    DOEpatents

    Harvey, Chris A.

    2008-12-16

    An offline solid phase microextraction (SPME) sampling apparatus for enabling SPME samples to be taken a number of times from a previously collected fluid sample (e.g. sample atmosphere) stored in a fused silica lined bottle which keeps volatile organics in the fluid sample stable for weeks at a time. The offline SPME sampling apparatus has a hollow body surrounding a sampling chamber, with multiple ports through which a portion of a previously collected fluid sample may be (a) released into the sampling chamber, (b) SPME sampled to collect analytes for subsequent GC analysis, and (c) flushed/purged using a fluidically connected vacuum source and purging fluid source to prepare the sampling chamber for additional SPME samplings of the same original fluid sample, such as may have been collected in situ from a headspace.

  16. Sonication contribution to identifying prosthetic joint infection with Ralstonia pickettii: a case report and review of the literature.

    PubMed

    Birlutiu, Rares Mircea; Roman, Mihai Dan; Cismasiu, Razvan Silviu; Fleaca, Sorin Radu; Popa, Crina Maria; Mihalache, Manuela; Birlutiu, Victoria

    2017-07-19

    In the context of an increase number of primary and revision total hip and total knee arthroplasty performed yearly, an increased risk of complication is expected. Prosthetic joint infection (PJI) remains the most common and feared arthroplasty complication. Ralstonia pickettii is a Gram-negative bacterium, that has also been identified in biofilms. It remains an extremely rare cause of PJI. There is no report of an identification of R. pickettii on an extracted spacer loaded with antibiotic. We present the case of an 83-years-old Caucasian male patient, that underwent a right cemented total hip replacement surgery. The patient is diagnosed with an early PJI with no isolated microorganism. A debridement and change of mobile parts is performed. At the beginning of 2016, the patient in readmitted into the Orthopedic Department for sever, right abdominal and groin pain and elevated serum erythrocyte sedimentation rate and C-reactive protein. A joint aspiration is performed with a negative microbiological examination. A two-stage exchange with long interval management is adopted, and a preformed spacer loaded with gentamicin was implanted. In July 2016, based on the proinflammatory markers evolution, a shift a three-stage exchange strategy is decided. In September 2016, a debridement, and changing of the preformed spacer loaded with gentamicin with another was carried out. Bacteriological examination of the tissues sampled intraoperatively was positive for Pseudomonas aeruginosa. From the sonication fluid, no bacteria were isolated on culture or identified using the bbFISH assay. During the hospitalization period, the patient received i.v. ceftazidime 3x2g/day and p.o. ciprofloxacin 2x750mg/day, antibiotic therapy that was continued after discharge with p.o. ciprofloxacin 2x750mg/day for 6 weeks. In February 2017, a reimplantation of a revision prosthesis is performed. The retrieved spacer is sonicated, and after 4 days of incubation of the sonication fluid, R

  17. Peritoneal fluid analysis

    MedlinePlus

    ... at fluid that has built up in the space in the abdomen around the internal organs. This area is called the peritoneal space. ... sample of fluid is removed from the peritoneal space using a needle and syringe. Ultrasound is often ...

  18. Peritoneal fluid culture

    MedlinePlus

    Culture - peritoneal fluid ... sent to the laboratory for Gram stain and culture. The sample is checked to see if bacteria ... The peritoneal fluid culture may be negative, even if you have ... diagnosis of peritonitis is based on other factors, in addition ...

  19. Characteristics of Hemorrhagic Stroke following Spine and Joint Surgeries.

    PubMed

    Yang, Fei; Zhao, Jianning; Xu, Haidong

    2017-01-01

    Hemorrhagic stroke can occur after spine and joint surgeries such as laminectomy, lumbar spinal fusion, tumor resection, and total joint arthroplasty. Although this kind of stroke rarely happens, it may cause severe consequences and high mortality rates. Typical clinical symptoms of hemorrhagic stroke after spine and joint surgeries include headache, vomiting, consciousness disturbance, and mental disorders. It can happen several hours after surgeries. Most bleeding sites are located in cerebellar hemisphere and temporal lobe. A cerebrospinal fluid (CSF) leakage caused by surgeries may be the key to intracranial hemorrhages happening. Early diagnosis and treatments are very important for patients to prevent the further progression of intracranial hemorrhages. Several patients need a hematoma evacuation and their prognosis is not optimistic.

  20. Assessment of the Utility of Cytology and Flow Cytometry of Cerebrospinal Fluid Samples in Clinical Practice.

    PubMed

    Nam, Anna S; Giorgadze, Tamara; Tam, Wayne; Chadburn, Amy

    2018-01-01

    We sought to assess the utility and limitations of both flow cytometry (FC) and cytology for the analysis of cerebrospinal fluid (CSF) in a practical clinical setting. A total of 393 consecutive CSF samples from 171 patients submitted for both cytomorphologic and FC assessments were analyzed. Both FC and cytology findings were negative for malignancy in 315/393 samples (80%), and either positive (POS) or suspicious/atypical (SUSP/AT) in 7% of samples. This resulted in high agreement between FC and cytology (87%). Minor discrepancies were present in 4% of the cases. In 28 samples, an abnormal population was detected by FC but not by cytology. FC and cytology are important complementary methods for analyzing CSF samples. In cases where cytology is SUSP/AT and FC is inconclusive or negative, additional specimens should be submitted for immunostaining, cytogenetics, and/or molecular studies. © 2018 S. Karger AG, Basel.

  1. Facilitation of bone resorption activities in synovial lavage fluid patients with mandibular condyle fractures.

    PubMed

    Takano, H; Takahashi, T; Nakata, A; Nogami, S; Yusa, K; Kuwajima, S; Yamazaki, M; Fukuda, M

    2016-05-01

    The aim of this study was to investigate the bone resorption effect of the mediators delivered in joint cavity of patients with mandibular condyle fractures by detecting osteoclast markers using cellular biochemistry methods, and by analysing bone resorption activities via inducing osteoclast differentiation of the infiltrated cells from arthrocentesis. Sixteen joints in 10 patients with mandibular condyle fractures were evaluated. The control group consisted of synovial fluid (SF) samples from seven joints of four volunteers who had no clinical signs or symptoms involving the temporomandibular joint (TMJ) or disc displacement. We collected SF cells from all patients during therapeutic arthrocentesis. The infiltrating cells from TMJ SF were cultured, differentiated into tartrate-resistant acid phosphatase (TRAP)-positive osteoclast-like cells and examined bone resorption activities. We also investigated factors related to osteoclast induction of SF, using ELISA procedures. Osteoclast-like cells were induced from the SF cells obtained from all patients with condylar fractures. These multinucleated giant cells were positive for TRAP and actin, and had the ability to absorb dentin slices. The levels of macrophage colony-stimulating factor (M-CSF), prostaglandin E2 (PGE2), soluble form of receptor activator of nuclear factor kappa-B ligand (sRANKL) and osteoprotegerin (OPG), in SF samples from the patients, were significantly higher than in the controls. These findings indicate that bone resorption activities in SF from patients with mandibular condyle fractures were upregulated and may participate in the pathogenesis and wound healing. © 2016 The Authors. Journal of Oral Rehabilitation Published by John Wiley & Sons Ltd.

  2. A systematic investigation of sample diluents in modern supercritical fluid chromatography.

    PubMed

    Desfontaine, Vincent; Tarafder, Abhijit; Hill, Jason; Fairchild, Jacob; Grand-Guillaume Perrenoud, Alexandre; Veuthey, Jean-Luc; Guillarme, Davy

    2017-08-18

    This paper focuses on the possibility to inject large volumes (up to 10μL) in ultra-high performance supercritical fluid chromatography (UHPSFC) under generic gradient conditions. Several injection and method parameters have been individually evaluated (i.e. analyte concentration, injection volume, initial percentage of co-solvent in the gradient, nature of the weak needle wash solvent, nature of the sample diluent, nature of the column and of the analyte). The most critical parameters were further investigated using in a multivariate approach. The overall results suggested that several aprotic solvents including methyl tert-butyl ether (MTBE), dichloromethane, acetonitrile or cyclopentyl methyl ether (CPME) were well adapted for the injection of large volume in UHPSFC, while MeOH was generally the worst alternative. However, the nature of the stationary phase also had a strong impact and some of these diluents did not perform equally on each column. This was due to the existence of a competition in the adsorption of the analyte and the diluent on the stationary phase. This observation introduced the idea that the sample diluent should not only be chosen according to the analyte but also to the column chemistry to limit the interactions between the diluent and the ligands. Other important characteristics of the "ideal" SFC sample diluent were finally highlighted. Aprotic solvents with low viscosity are preferable to avoid strong solvent effects and viscous fingering, respectively. In the end, the authors suggest that the choice of the sample diluent should be part of the method development, as a function of the analyte and the selected stationary phase. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Surface sampling concentration and reaction probe with controller to adjust sampling position

    DOEpatents

    Van Berkel, Gary J.; ElNaggar, Mariam S.

    2016-07-19

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  4. Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

    USGS Publications Warehouse

    Simon, N.S.

    1997-01-01

    Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

  5. Total antioxidant capacity and total oxidant status of synovial fluids in patients with temporomandibular joint pain and dysfunction.

    PubMed

    Etöz, Osman A; Akçay, Hüseyin; Neşelioğlu, Salim; Erel, Özcan; Alkan, Alper

    2012-12-01

    The objective of this study was to investigate whether a relationship exists between total antioxidant capacity (TAC) and total oxidant status (TOS) of synovial fluids (SFs) of temporomandibular joint (TMJ) pain patients with pain and dysfunction. Forty-two patients with TMJ pain were included in this study. TAC and TOS values of SFs were measured with a novel colorimetric method. Independent t test and correlations were used to analyze the data. TAC of SFs in patients with TMJ pain and limited mouth opening (LMO; n = 21) were significantly lower (P = 0.03) than patients without LMO (n = 21). TOS of SF was negatively correlated with duration of the disease. There was no correlation between TAC, TOS, and VAS scores of the patients as well as age and maximum mouth opening values. Antioxidant response to oxidative changes (TAC and TOS) in SF decreased as the stage of dysfunction increased. Local administration of antioxidant agents might be considered in management of TMJ pain and dysfunction to prevent possible increased oxidative stress.

  6. Comparison of direct sampling and brochoalveolar lavage for determining active drug concentrations in the pulmonary epithelial lining fluid of calves injected with enrofloxacin or tilmicosin.

    PubMed

    Foster, D M; Sylvester, H J; Papich, M G

    2017-12-01

    Antibiotic distribution to interstitial fluid (ISF) and pulmonary epithelial fluid (PELF) was measured and compared to plasma drug concentrations in eight healthy calves. Enrofloxacin (Baytril ® 100) was administered at a dose of 12.5 mg/kg subcutaneously (SC), and tilmicosin (Micotil ® 300) was administered at a dose of 20 mg/kg SC. PELF, sampled by two different methods-bronchoalveolar lavage (BAL) and direct sampling (DS)-plasma, and ISF were collected from each calf and measured for tilmicosin, enrofloxacin and its metabolite ciprofloxacin by HPLC. Pharmacokinetic analysis was performed on the concentrations in each fluid, for each drug. The enrofloxacin/ciprofloxacin concentration as measured by AUC in DS samples was 137 ± 72% higher than in plasma, but in BAL samples, this value was 535 ± 403% (p < .05). The concentrations of tilmicosin in DS and BAL samples exceeded plasma drug concentrations by 567 ± 189% and 776 ± 1138%, respectively. The enrofloxacin/ciprofloxacin concentrations collected by DS were significantly different than those collected by BAL, but the tilmicosin concentrations were not significantly different between the two methods. Concentrations of enrofloxacin/ciprofloxacin exceeded the MIC values for bovine respiratory disease pathogens but tilmicosin did not reach MIC levels for these pathogens in any fluids. © 2017 John Wiley & Sons Ltd.

  7. An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation.

    PubMed

    Royhman, Dmitry; Radhakrishnan, Rashmi; Yuan, Judy Chia-Chun; Mathew, Mathew T; Mercuri, Louis G; Sukotjo, Cortino

    2014-10-01

    To investigate the corrosion behaviour of commonly used TMJ implants alloys (CoCrMo and Ti6Al4V) under simulated physiological conditions. Corrosion behaviour was evaluated using standard electrochemical corrosion techniques and galvanic corrosion techniques as per ASTM standards. Standard electrochemical tests (E(corr), I(corr), R(p) and C(f)) were conducted in bovine calf serum (BCS), as a function of alloys type and different pHs. Galvanic corrosion tests were conducted in BCS at a pH of 7.6. Alloy surfaces were characterized using white-light interferometry (WLI) and scanning electron microscopy (SEM). The potentiodynamic test results exhibited the enhanced passive layer growth and a better corrosion resistance of Ti6Al4V compared to CoCrMo. Electrochemical impedance spectroscopy measurements demonstrated the influence of protein as a function of pH on corrosion mechanisms/kinetics. Galvanic coupling was not a major contributor to corrosion. SEM and WLI images demonstrated a significantly higher in surface roughness in CoCrMo after corrosion. The results of this study suggest that Ti6Al4V shows superior corrosion behaviour to CoCrMo due to its strong passive layer, simulated joint fluid components can affect the electrochemical nature of the metal/electrolyte interface as a function of pH, and the galvanic effect of coupling CoCrMo and Ti6Al4V in a single joint is weak. Published by Elsevier Ltd.

  8. Instability in Immiscible Fluids Displacement from Cracks and Porous Samples

    NASA Astrophysics Data System (ADS)

    Smirnov, N. N.; Nikitin, V. F.; Ivashnyov, O. E.

    2002-01-01

    problems of terrestrial engineering and technology. Surface tension affected flows in porous media could be much better understood in microgravity studies eliminating the masking effects of gravity. Saffman-Taylor instability of the interface could bring to formation and growth of "fingers" of gas penetrating the bulk fluid. The growth of fingers and their further coalescence could not be described by the linear analysis. Growth of fingers causes irregularity of the mixing zone. The tangential velocity difference on the interface separating fluids of different densities and viscousities could bring to a Kelvin-Helmholtz instability resulting in "diffusion of fingers" partial regularization of the displacement mixing zone. Thus combination of the two effects would govern the flow in the displacement process. fracture under a pressure differential displacing the high viscosity residual fracturing fluid. There are inherent instability and scalability problems associated with viscous fingering that play a key role in the cleanup procedure. Entrapment of residual fracturing fluid by the gas flow lowers down the quality of a fracture treatment leaving most of fluid in the hydraulic fracture thus decreasing the production rate. The gravity effects could play essential role in vertical hydraulic fractures as the problem is scale dependent. displacement of viscous fluid by a less viscous one in a two-dimensional channel with vertical breaks, and to determine characteristic size of entrapment zones. Extensive direct numerical simulations allow to investigate the sensitivity of the displacement process to variation of values of the main governing parameters. were found for the two limiting cases: infinitely wide cell, and narrow cell with an infinitely small gap between the finger and the side walls. governing parameters. The obtained solutions allowed to explain the physical meaning of the exiting empirical criteria for the beginning of viscous fingering and the growth of a

  9. An investigation of the optical properties of cholesterol crystals in human synovial fluid

    NASA Astrophysics Data System (ADS)

    Zakharova, M. M.; Nasonova, V. A.; Konstantinova, A. F.; Chudakov, V. S.; Gaĭnutdinov, R. V.

    2009-05-01

    The synovial fluid of patients with rheumatoid diseases has been investigated. The presence of cholesterol crystals in the synovial fluid is revealed by polarization microscopy. A comparative analysis of the composition and properties of synovial fluid and the optical properties of cholesterol crystals is performed. It is established that the size, number, and growth of cholesterol crystals are interrelated to the synovial fluid composition. It is shown that rheumatoid diseases can be accompanied by the formation of cholesterol crystals in the synovial fluid from different joints and in rheumatic nodules. It is shown that all investigated crystals have a significant birefringence.

  10. Effect of a single intra-articular injection of bupivacaine on synovial fluid prostaglandin E2 concentrations in normal canine stifles.

    PubMed

    Giangarra, Jenna E; Barry, Sabrina L; Dahlgren, Linda A; Lanz, Otto I; Benitez, Marian E; Werre, Stephen R

    2018-04-25

    To identify if synovial fluid prostaglandin E 2 increases in response to a single intra-articular dose of bupivacaine in the normal canine stifle. There were no significant differences in synovial fluid prostaglandin E 2 (PGE 2 ) concentrations between treatment groups or over time within bupivacaine or saline groups. Samples requiring ≥ 3 arthrocentesis attempts had significantly higher PGE 2 concentrations compared to samples requiring 1 or 2 attempts. Following correction for number of arthrocentesis attempts, PGE 2 concentrations were significantly higher than baseline at 24 and 48 h in the bupivacaine group; however there were no significant differences between the bupivacaine and saline groups. In normal dogs, a single bupivacaine injection did not cause significant synovial inflammation, as measured by PGE 2 concentrations, compared to saline controls. Future research should minimize aspiration attempts and include evaluation of the synovial response to bupivacaine in clinical cases with joint disease.

  11. [Intra-articular injections of hyaluronic acid for anterior disc displacement of temporomandibular joint].

    PubMed

    Long, X

    2017-03-09

    Anterior disc displacement (ADD) of temporomandibular joint (TMJ) is regarded as one of the major findings in temporomandibular disorders (TMD). It is related to joint noise, pain, mandibular dysfunction, degenerative change and osteoarthritis. In the mean time, the pathological changes were found in synovial membrane and synovial fluid. Hyaluronic acid is a principal component of the synovial fluid which plays an important role in nutrition, lubrication, anti-inflammation and cartilage repair. The synthesis, molecule weight, and concentration of hyaluronic acid are decreased during TMD and cause TMJ degenerative changes. The clinical conditions, pathological changes, the mechanism of action for hyaluronic acid and the treatment of anterior disc displacement of TMJ are discussed in this article.

  12. Adhesive Bonding Characterization of Composite Joints for Cryogenic Usage

    NASA Technical Reports Server (NTRS)

    Graf, Neil A.; Schieleit, Gregory F.; Biggs, Robert

    2000-01-01

    The development of polymer composite cryogenic tanks is a critical step in creating the next generation of launch vehicles. Future reusable launch vehicles need to minimize the gross liftoff weight (GLOW). This weight reduction is possible due to the large reduction in weight that composite materials can provide over current aluminum technology. In addition to composite technology, adhesively bonded joints potentially have several benefits over mechanically fastened joints, such as weight savings and cryogenic fluid containment. Adhesively bonded joints may be used in several areas of these cryogenic tanks, such as in lobe-to-lobe joints (in a multi-lobe concept), skirt-to-tank joint, strut-to-tank joint, and for attaching stringers and ring frames. The bonds, and the tanks themselves, must be able to withstand liquid cryogenic fuel temperatures that they contain. However, the use of adhesively bonded composite joints at liquid oxygen and hydrogen temperatures is largely unknown and must be characterized. Lockheed Martin Space Systems Company, Michoud Operations performed coupon-level tests to determine effects of material selection, cure process parameters, substrate surface preparation, and other factors on the strength of these composite joints at cryogenic temperatures. This led to the selection of a material and process that would be suitable for a cryogenic tank. KEY WORDS: Composites, Adhesive Bonding, Cryogenics

  13. Identification of Synovial Fluid Biomarkers for Knee Osteoarthritis and Correlation with Radiographic Assessment.

    PubMed

    Monibi, Farrah; Roller, Brandon L; Stoker, Aaron; Garner, Bridget; Bal, Sonny; Cook, James L

    2016-04-01

    Osteoarthritis (OA) is a costly and debilitating condition that is typically not diagnosed early enough to prevent progression of disease. The purpose of this study was to evaluate synovial fluid from knees with and without OA for potential markers of joint inflammation and degradation and to correlate these findings with radiographic severity of disease. With Institutional Review Board approval, synovial fluid samples were collected before the patient undergoing total knee arthroplasty. Control knees (n = 3) were patients younger than 30 years of age with no history of anterior cruciate ligament, posterior cruciate ligament, or meniscal injury, and no surgical history for either knee. Weight-bearing, anterior-posterior radiographic views were used to determine radiographic OA severity using the modified Kellgren and Lawrence scale. Synovial fluid samples from 18 patients (21 knees) were analyzed using a multiplex assay. Matrix metalloproteinase (MMP)-1 (p < 0.001), interleukin (IL)-6 (p < 0.013), IL-8 (p < 0.024), and Chemokine (C-C motif) ligand 5 (CCL5) (p < 0.006) were significantly higher in the synovial fluid of OA patients compared with normal patients. The radiographic score was significantly higher in patients with OA compared with normal knees (p < 0.002). MMP-1 had a moderate positive correlation with MMP-2, IL-6, IL-8, and CCL5. IL-6 had a strong positive correlation with IL-8 and a moderate positive correlation with MMP-2. Monocyte chemotactic protein 1 had a moderate positive correlation with IL-6 and a strong positive correlation with IL-8. Radiographic scores had a strong positive correlation with IL-6 and IL-8 and a moderate positive correlation with MCP-1. These data provide novel and clinically relevant information for the investigation of synovial fluid biomarkers for knee OA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Sliding enhances fluid and solute transport into buried articular cartilage contacts.

    PubMed

    Graham, B T; Moore, A C; Burris, D L; Price, C

    2017-12-01

    Solutes and interstitial water are naturally transported from cartilage by load-induced interstitial fluid pressures. Fluid and solute recovery during joint articulation have been primarily attributed to passive diffusion and mechanical 'pumping' from dynamic loading. This paper tests if the sliding action of articulation is a significant and independent driver of fluid and solute transport in cartilage. The large osteochondral samples utilized in the present study preserve the convergent wedges necessary for physiological hydrodynamics. Following static load-induced fluid exudation and prior to sliding, a fluorescent solute (AlexaFluor 633) was added to the lubricant bath. In situ confocal microscopy was used to quantify the transport of solute from the bath into the buried stationary contact area (SCA) during sliding. Following static exudation, significant reductions in friction and strain during sliding at 60 mm/s were accompanied by significant solute transport into the inaccessible center of the buried contact; no such transport was detected for the 0- or 1 mm/s sliding conditions. The results suggest that external hydrodynamic pressures from sliding induced advective flows that carried solutes from the bath toward the center of contact. These results provide the first direct evidence that the action of sliding is a significant contributor to fluid and solute recovery by cartilage. Furthermore, they indicate that the sliding-induced transport of solutes into the buried interface was orders of magnitude greater than that attributable to diffusion alone, a result with critical implications for disease prevention and tissue engineering. Copyright © 2017 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Sodium inversion recovery MRI of the knee joint in vivo at 7T.

    PubMed

    Madelin, Guillaume; Lee, Jae-Seung; Inati, Souheil; Jerschow, Alexej; Regatte, Ravinder R

    2010-11-01

    The loss of proteoglycans (PG) in the articular cartilage is an early signature of osteoarthritis (OA). The ensuing changes in the fixed charge density in the cartilage can be directly linked to sodium concentration via charge balance. Sodium ions in the knee joint appear in two pools: in the synovial fluids or joint effusion where the ions are in free motion and bound within the cartilage tissue where the Na(+) ions have a restricted motion. The ions in these two compartments have therefore different T₁ and T₂ relaxation times. The purpose of this study is to demonstrate the feasibility of a fluid-suppressed 3D ultrashort TE radial sodium sequence by implementing an inversion recovery (IR) preparation of the magnetization at 7T. This method could allow a more accurate and more sensitive quantification of loss of PG in patients with OA. It is shown that adiabatic pulses offer significantly improved performance in terms of robustness to B₁ and B₀ inhomogeneities when compared to the hard pulse sequence. Power deposition considerations further pose a limit to the RF inversion power, and we demonstrate in simulations and experiments how a practical compromise can be struck between clean suppression of fluid signals and power deposition levels. Two IR sequences with different types of inversion pulses (a rectangular pulse and an adiabatic pulse) were tested on a liquid phantom, ex vivo on a human knee cadaver and then in vivo on five healthy volunteers, with a (Nyquist) resolution of ∼3.6 mm and a signal-to-noise ratio of ∼30 in cartilage without IR and ∼20 with IR. Due to specific absorption rate limitations, the total acquisition time was ∼17 min for the 3D radial sequence without inversion or with the rectangular IR, and 24:30 min for the adiabatic IR sequence. It is shown that the adiabatic IR sequence generates a more uniform fluid suppression over the whole sample than the rectangular IR sequence. Copyright © 2010 Elsevier Inc. All rights

  16. Sodium inversion recovery MRI of the knee joint in vivo at 7T

    NASA Astrophysics Data System (ADS)

    Madelin, Guillaume; Lee, Jae-Seung; Inati, Souheil; Jerschow, Alexej; Regatte, Ravinder R.

    2010-11-01

    The loss of proteoglycans (PG) in the articular cartilage is an early signature of osteoarthritis (OA). The ensuing changes in the fixed charge density in the cartilage can be directly linked to sodium concentration via charge balance. Sodium ions in the knee joint appear in two pools: in the synovial fluids or joint effusion where the ions are in free motion and bound within the cartilage tissue where the Na+ ions have a restricted motion. The ions in these two compartments have therefore different T1 and T2 relaxation times. The purpose of this study is to demonstrate the feasibility of a fluid-suppressed 3D ultrashort TE radial sodium sequence by implementing an inversion recovery (IR) preparation of the magnetization at 7T. This method could allow a more accurate and more sensitive quantification of loss of PG in patients with OA. It is shown that adiabatic pulses offer significantly improved performance in terms of robustness to B1 and B0 inhomogeneities when compared to the hard pulse sequence. Power deposition considerations further pose a limit to the RF inversion power, and we demonstrate in simulations and experiments how a practical compromise can be struck between clean suppression of fluid signals and power deposition levels. Two IR sequences with different types of inversion pulses (a rectangular pulse and an adiabatic pulse) were tested on a liquid phantom, ex vivo on a human knee cadaver and then in vivo on five healthy volunteers, with a (Nyquist) resolution of ∼3.6 mm and a signal-to-noise ratio of ∼30 in cartilage without IR and ∼20 with IR. Due to specific absorption rate limitations, the total acquisition time was ∼17 min for the 3D radial sequence without inversion or with the rectangular IR, and 24:30 min for the adiabatic IR sequence. It is shown that the adiabatic IR sequence generates a more uniform fluid suppression over the whole sample than the rectangular IR sequence.

  17. Pericardial fluid Gram stain

    MedlinePlus

    ... stain To use the sharing features on this page, please enable JavaScript. Pericardial fluid Gram stain is a method of staining a sample of fluid taken from the pericardium. This is the sac surrounding ...

  18. A new framework of statistical inferences based on the valid joint sampling distribution of the observed counts in an incomplete contingency table.

    PubMed

    Tian, Guo-Liang; Li, Hui-Qiong

    2017-08-01

    Some existing confidence interval methods and hypothesis testing methods in the analysis of a contingency table with incomplete observations in both margins entirely depend on an underlying assumption that the sampling distribution of the observed counts is a product of independent multinomial/binomial distributions for complete and incomplete counts. However, it can be shown that this independency assumption is incorrect and can result in unreliable conclusions because of the under-estimation of the uncertainty. Therefore, the first objective of this paper is to derive the valid joint sampling distribution of the observed counts in a contingency table with incomplete observations in both margins. The second objective is to provide a new framework for analyzing incomplete contingency tables based on the derived joint sampling distribution of the observed counts by developing a Fisher scoring algorithm to calculate maximum likelihood estimates of parameters of interest, the bootstrap confidence interval methods, and the bootstrap testing hypothesis methods. We compare the differences between the valid sampling distribution and the sampling distribution under the independency assumption. Simulation studies showed that average/expected confidence-interval widths of parameters based on the sampling distribution under the independency assumption are shorter than those based on the new sampling distribution, yielding unrealistic results. A real data set is analyzed to illustrate the application of the new sampling distribution for incomplete contingency tables and the analysis results again confirm the conclusions obtained from the simulation studies.

  19. Constraints On Fluid Evolution During Mid-Ocean Ridge Hydrothermal Circulation From Anhydrite Sampled by ODP Hole 1256D

    NASA Astrophysics Data System (ADS)

    Smith-Duque, C.; Teagle, D. A.; Alt, J. C.; Cooper, M. J.

    2008-12-01

    Sr/Ca ratios reduce greatly during recharge before there is significant Sr exchange with the host basalts. δ18O measurements display an irregular trend with depth from +17‰ in the lower volcanics to +10‰ in the sheeted dikes suggesting an increase in precipitation temperatures from 105 to 211°C. One sample, from a chalcopyrite mineralized dike margin has a very light δ18O of +2.2‰ suggesting a temperature of ~408°, perhaps indicating that fluid was superheated following direct contact with the hot intrusive body. This sample also records low 87Sr/86Sr and high total REE.

  20. Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation.

    PubMed

    Jahan, M S; Wang, C; Schwartz, G; Davidson, J A

    1991-08-01

    An electron spin resonance (ESR) technique is employed to determine the free radical distribution in the articulating surfaces of retrieved acetabular cups and knee-joint plateaus (retrieved after more than 6 years of implantation). Similar measurements made on samples prepared from cyclically stressed and unstressed cups, and on samples following oxidations in nitric acid and intralipid solutions provided sufficient data to gain more knowledge about the combined chemical and mechanical effects on PE free radicals during implantation. In UHMWPE free radicals are primarily initiated by gamma-ray sterilization; however, during implantation, peroxy (scission type) free radicals are formed and reach a maximum concentration level (equilibrium state) due to oxidation by chemical (hemoglobin and/or synovial fluids) environment of the joints. Subsequently, due to frictional heating and stress in the loading zones, free radical reaction is accelerated and their number is reduced only in those areas. This is consistent with the observations of a temperature rise in acetabular cups during in vitro frictional wear stress tests and in vivo telemetry observations, as reported by others. Compared with the previously reported SEM micrographs the low-free-radical regions are correlated with high-wear areas and the high-free-radical regions with the low-wear areas.

  1. Muscle contributions to elbow joint rotational stiffness in preparation for sudden external arm perturbations.

    PubMed

    Holmes, Michael W R; Keir, Peter J

    2014-04-01

    Understanding joint stiffness and stability is beneficial for assessing injury risk. The purpose of this study was to examine joint rotational stiffness for individual muscles contributing to elbow joint stability. Fifteen male participants maintained combinations of three body orientations (standing, supine, sitting) and three hand preloads (no load, solid tube, fluid filled tube) while a device imposed a sudden elbow extension. Elbow angle and activity from nine muscles were inputs to a biomechanical model to determine relative contributions to elbow joint rotational stiffness, reported as percent of total stiffness. A body orientation by preload interaction was evident for most muscles (P<.001). Brachioradialis had the largest change in contribution while standing (no load, 18.5%; solid, 23.8%; fluid, 26.3%). Across trials, the greatest contributions were brachialis (30.4±1.9%) and brachioradialis (21.7±2.2%). Contributions from the forearm muscles and triceps were 5.5±0.6% and 9.2±1.9%, respectively. Contributions increased at time points closer to the perturbation (baseline to anticipatory), indicating increased neuromuscular response to resist rotation. This study quantified muscle contributions that resist elbow perturbations, found that forearm muscles contribute marginally and showed that orientation and preload should be considered when evaluating elbow joint stiffness and safety.

  2. Disappearance kinetics of solutes from synovial fluid after intra-articular injection.

    PubMed Central

    Owen, S G; Francis, H W; Roberts, M S

    1994-01-01

    1. Five rheumatoid patients with a knee joint effusion participated in the study. An aqueous solution (0.1 to 0.2 ml) containing paracetamol, salicylate, diclofenac and [125I]-albumin was injected into a given joint to yield target concentrations of approximately 20 micrograms ml-1 for diclofenac, salicylate and paracetamol and 10(8) counts ml-1 for [125I]-albumin. 2. Paracetamol, salicylate and diclofenac were analysed in synovial fluid by h.p.l.c. [125I]-albumin was analysed using gamma counting. 3. The clearances (+/- s.d.) obtained for the solutes were [125I]-albumin (0.0053 +/- 0.0019 l h-1), diclofenac (0.0096 +/- 0.0061 l h-1), salicylate (0.024 +/- 0.022 l h-1) and paracetamol (0.055 +/- 0.041 l h-1). The corresponding fractions unbound of these solutes in synovial fluid were 0.0, < or = 0.01, 0.34 +/- 0.09 and 0.85 +/- 0.10, respectively. 4. Diffusion of unbound solute through the synovium is estimated to account for (+/- s.d.) 0.52 +/- 0.08, 0.87 +/- 0.06 and 0.99 +/- 0.01 of the total clearance of diclofenac, salicylate and paracetamol from the joint space, respectively. The remaining proportion of clearance is accounted for by efflux of solute bound to albumin. 5. An expression for the ratio of synovial fluid to total plasma concentrations after systemic administration was developed to include both diffusion of unbound solute and albumin flux. Most solutes appear to satisfy the conditions in which this expression reduces to the limiting case where the unbound concentration of the solute is identical in the synovial fluid and plasma under steady state conditions. PMID:7833225

  3. The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers.

    PubMed

    Li, Junyan; Stewart, Todd D; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John

    2013-06-21

    Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layers☆

    PubMed Central

    Li, Junyan; Stewart, Todd D.; Jin, Zhongmin; Wilcox, Ruth K.; Fisher, John

    2013-01-01

    Computational models of the natural hip joint are needed to examine and optimise tissue sparing interventions where the natural cartilage remains part of the bearing surfaces. Although the importance of interstitial fluid pressurisation in the performance of cartilage has long been recognized, few studies have investigated the time dependent interstitial fluid pressurisation in a three dimensional natural hip joint model. The primary aim of this study was to develop a finite element model of the natural hip incorporating the biphasic cartilage layers that was capable of simulating the joint response over a prolonged physiological loading period. An initial set of sensitivity studies were also undertaken to investigate the influence of hip size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the joint. The contact stress, contact area, fluid pressure and fluid support ratio were calculated and cross-compared between models with different parameters to evaluate their influence. It was found that the model predictions for the period soon after loading were sensitive to the hip size, clearance, cartilage aggregate modulus, thickness and hemiarthroplasty, while the time dependent behaviour over 3000 s was influenced by the hip clearance and cartilage aggregate modulus, permeability, thickness and hemiarthroplasty. The modelling methods developed in this study provide a basic platform for biphasic simulation of the whole hip joint onto which more sophisticated material models or other input parameters could be added in the future. PMID:23664238

  5. Direct and indirect markers of cartilage metabolism in synovial fluid obtained from dogs with hip dysplasia and correlation with clinical and radiographic variables.

    PubMed

    Fujita, Yukihiro; Hara, Yasushi; Nezu, Yoshinori; Yamaguchi, Shinya; Schulz, Kurt S; Tagawa, Masahiro

    2005-12-01

    To compare activities of interleukin (IL)-1beta, IL-6, tumor necrosis factor (TNF)-alpha, and matrix metalloproteinase (MMP)-3 and contents of sulfated glycosaminoglycan (S-GAG) in joint fluid obtained from dogs with hip dysplasia (HD) and clinically normal dogs, evaluate correlations among these markers in joint fluid obtained from dogs with HD, and evaluate correlations between each marker and clinical and radiographic variables. Animals-26 dogs with HD (clinical group) and 43 clinically normal Beagles (control group). Joint fluid was aseptically collected from the hip joints of all dogs. For each dog in the clinical group, age, duration of lameness, radiographic osteoarthritis (OA) score, and Norberg angle in each affected joint were recorded. Activities of IL-1beta, IL-6, TNF-alpha, and MMP-3 and S-GAG contents were measured. Values were compared between groups by use of Mann-Whitney U tests, and the Spearman rank correlation test was used to evaluate correlations among markers and between each marker and clinical or radiographic variables. Values of all markers were significantly higher for the clinical group, compared with values for the control group. There was a moderate positive correlation between lameness duration and IL-6 activity and a strong negative correlation between the Norberg angle and IL-1beta activity. Analysis of our results indicated that there was a significant increase in markers of OA in dogs with HD. Activities of IL-1beta and IL-6 in joint fluid of dogs with HD may be influenced by the severity of laxity in the hip joint and lameness duration, respectively.

  6. Supercritical fluid chromatography coupled with tandem mass spectrometry: A high-efficiency detection technique to quantify Taxane drugs in whole-blood samples.

    PubMed

    Jin, Chan; Guan, Jibin; Zhang, Dong; Li, Bing; Liu, Hongzhuo; He, Zhonggui

    2017-10-01

    We present a technique to rapid determine taxane in blood samples by supercritical fluid chromatography together with mass spectrometry. The aim of this study was to develop a supercritical fluid chromatography with mass spectrometry method for the analysis of paclitaxel, cabazitaxel, and docetaxel in whole-blood samples of rats. Liquid-dry matrix spot extraction was selected in sample preparation procedure. Supercritical fluid chromatography separation of paclitaxel, cabazitaxel, docetaxel, and glyburide (internal standard) was accomplished within 3 min by using the gradient mobile phase consisted of methanol as the compensation solvent and carbon dioxide at a flow rate of 1.0 mL/min. The method was validated regarding specificity, the lower limit of quantification, repeatability, and reproducibility of quantification, extraction recovery, and matrix effects. The lower limit of quantification was found to be 10 ng/mL since it exhibited acceptable precision and accuracy at the corresponding level. All interday accuracies and precisions were within the accepted criteria of ±15% of the nominal value and within ±20% at the lower limit of quantification, implying that the method was reliable and reproducible. In conclusion, this method is a promising tool to support and improve preclinical or clinical pharmacokinetic studies with the taxanes anticancer drugs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Acoustic waveform of continuous bubbling in a non-Newtonian fluid.

    PubMed

    Vidal, Valérie; Ichihara, Mie; Ripepe, Maurizio; Kurita, Kei

    2009-12-01

    We study experimentally the acoustic signal associated with a continuous bubble bursting at the free surface of a non-Newtonian fluid. Due to the fluid rheological properties, the bubble shape is elongated, and, when bursting at the free surface, acts as a resonator. For a given fluid concentration, at constant flow rate, repetitive bubble bursting occurs at the surface. We report a modulation pattern of the acoustic waveform through time. Moreover, we point out the existence of a precursor acoustic signal, recorded on the microphone array, previous to each bursting. The time delay between this precursor and the bursting signal is well correlated with the bursting signal frequency content. Their joint modulation through time is driven by the fluid rheology, which strongly depends on the presence of small satellite bubbles trapped in the fluid due to the yield stress.

  8. Nerve growth factor concentrations in the synovial fluid from healthy dogs and dogs with secondary osteoarthritis.

    PubMed

    Isola, M; Ferrari, V; Miolo, A; Stabile, F; Bernardini, D; Carnier, P; Busetto, R

    2011-01-01

    To measure the concentrations of nerve growth factor (NGF) in the synovial fluid from normal dogs and dogs with osteoarthritis (OA) secondary to common joint disorders. Nerve growth factor synovial concentrations were measured by ELISA assay in 50 dogs divided into three groups: 12 healthy, 16 affected by acute lameness within seven days before enrolment, and 22 with chronic lameness persisting by more than one month before enrolment and accompanied by radiological signs of OA. Both acute and chronic lameness were secondary to orthopaedic diseases involving the shoulder, elbow and stifle joints. Nerve growth factor synovial concentrations were compared between means for healthy and acute groups and between the three groups using an F-test. Significance level was set at p <0.05. Nerve growth factor was detected in all canine synovial fluid samples. However, the mean synovial NGF concentration of healthy dogs (3.65 ± 2.18 pg/ml) was not significantly different from the mean value in dogs with acute lameness (6.45 ± 2.45 pg/ml) (p = 0.79). Conversely, the mean synovial NGF concentration in dogs with chronic lameness (20.19 ± 17.51 pg/ml) was found to be significantly higher than that found in healthy dogs (p <0.01). This study demonstrates for the first time the presence of NGF in canine synovial fluid and its increased concentrations in dogs with chronic lameness compared to healthy dogs and dogs with acute lameness. The association between chronic lameness and raised synovial concentrations may suggest an involvement of NGF in OA inflammation and chronic pain.

  9. Seismic intensity monitoring: from mature basins in the North Sea to sample-scale porosity measurements.

    NASA Astrophysics Data System (ADS)

    De Siena, Luca; Sketsiou, Panayiota

    2017-04-01

    We plan the application of a joint velocity, attenuation, and scattering tomography to the North Sea basins. By using seismic phases and intensities from previous passive and active surveys our aim is to image and monitor fluids under the subsurface. Seismic intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the volcanoes and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island), continental calderas (Campi Flegrei) and Quaternary Volcanoes (Mount. St. Helens) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability, with as key output a novel computational code with strong commercial potential. Data are readily available in the framework of the NERC CDT Oil & Gas project.

  10. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species

    PubMed Central

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2017-01-01

    Objective Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain in the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. Materials and Methods The study population consisted of 100 singleton pregnant women who delivered preterm neonates (<35weeks) within 7 days of amniocentesis. Gastric fluid of newborns was obtained by nasogastric intubation on the day of birth. Amniotic fluid and gastric fluid were cultured for genital Mycoplasmas and polymerase chain reaction (PCR) for Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (> 23ng/mL). Results 1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; 2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; 3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; 4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and 5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic

  11. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species.

    PubMed

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2016-01-01

    Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain of the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. The study population consisted of 100 singleton pregnant women who delivered preterm neonates (<35 weeks) within 7 days of amniocentesis. Gastric fluid of newborns was obtained by nasogastric intubation on the day of birth. Amniotic fluid and gastric fluid were cultured for genital Mycoplasmas, and polymerase chain reaction (PCR) for Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (>23 ng/mL). (1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; (2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; (3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; (4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and (5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death

  12. The effect of robenacoxib on the concentration of C-reactive protein in synovial fluid from dogs with osteoarthritis.

    PubMed

    Bennett, David; Eckersall, Peter David; Waterston, Mary; Marchetti, Veronica; Rota, Alessandra; McCulloch, Eilidh; Sbrana, Silvia

    2013-03-01

    Robenacoxib is a novel and highly selective inhibitor of COX-2 in dogs and cats and because of its acidic nature is regarded as being tissue-selective. Thirty four dogs with stifle osteoarthritis secondary to failure of the cranial cruciate ligament were recruited into this study. Lameness, radiographic features, synovial cytology and C-reactive protein concentrations in serum and synovial fluid were assessed before and 28 days after commencing a course of Robenacoxib at a dose of 1 mg/kg SID. There was a significant reduction in the lameness score (P < 0.01) and an increase in the radiographic score (P < 0.05) between pre- and post-treatment assessments. There was no difference between pre- (median 1.49 mg/l; Q1-Q3 0.56-4.24 mg/L) and post - (1.10 mg/L; 0.31-1.78 mg/L) treatment serum C-reactive protein levels although synovial fluid levels were significantly reduced (pre- : 0.44 mg/L; 0.23-1.62 mg/L; post- : 0.17 mg/L; 0.05-0.49 mg/L) (P < 0.05). There was no correlation between C-reactive protein concentrations in serum and matched synovial fluid samples. Robenacoxib proved effective in reducing lameness in dogs with failure of the cranial cruciate ligament and osteoarthritis of the stifle joint. The drug also reduced levels of C-reactive protein in the synovial fluid taken from the affected stifle joint. Robenacoxib appears to reduce articular inflammation as assessed by C-reactive protein which supports the concept that Robenacoxib is a tissue-selective non-steroidal anti-inflammatory drug.

  13. Mineral oil metal working fluids (MWFs)-development of practical criteria for mist sampling.

    PubMed

    Simpson, A T; Groves, J A; Unwin, J; Piney, M

    2000-05-01

    Not all mineral oil metalworking fluids (MWFs) in common use form stable airborne mists which can be sampled quantitatively onto a filter. This much has been known for some time but no simple method of identifying oils too volatile for customary filter sampling has been developed. Past work was reviewed and experiments were done to select simple criteria which would enable such oils to be identified. The sampling efficiency for a range of commercial mineral oil MWF were assessed by drawing clean air through spiked filters at 2 l. min(-1) for periods up to 6 h before analysis. The physical properties of MWF are governed by their composition and kinematic viscosity was found to be the most practical and easily available index of the potential for sample loss from the filter. Oils with viscosities greater that 18 cSt (at 40 degrees C) lost less than 5% of their weight, whereas those with viscosities less than 18 cSt gave losses up to 71%. The losses from the MWF were mostly aliphatic hydrocarbons (C(10)-C(18)), but additives such as alkyl benzenes, esters, phenols and terpene odorants were also lost. The main recommendation to arise from the work is that filter sampling can be performed on mineral oils with viscosities of 18 cSt (at 40 degrees C) or more with little evaporative losses from the filter. However, sampling oils with viscosities less than 18 cSt will produce results which may significantly underestimate the true value. Over a quarter of UK mineral oil MWFs are formulated from mineral oils with viscosities less than 18 cSt (at 40 degrees C). The problem of exposure under-estimation and inappropriate exposure sampling could be widespread. Further work is being done on measurement of mixed phase mineral oil mist exposure.

  14. Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    PubMed

    Lundberg, Hannah J; Pedersen, Douglas R; Baer, Thomas E; Muste, Marian; Callaghan, John J; Brown, Thomas D

    2007-01-01

    Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.

  15. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    PubMed

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  16. Efficacy of the FilmArray blood culture identification panel for direct molecular diagnosis of infectious diseases from samples other than blood.

    PubMed

    Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere

    2015-12-01

    Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.

  17. Containment of fluid samples in the hydrothermal diamond-anvil cell without the use of metal gaskets: Performance and advantages for in situ analysis

    NASA Astrophysics Data System (ADS)

    Chou, I.-Ming; Bassett, William A.; Anderson, Alan J.; Mayanovic, Robert A.; Shang, Linbo

    2008-11-01

    Metal gaskets (Re, Ir, Inconel, or stainless steel) normally used to contain fluid samples in the hydrothermal diamond-anvil cell (HDAC) are sometimes undesirable due to possible contamination and to gasket deformation at high pressures and temperatures resulting in nonisochoric behavior. Furthermore, in x-ray spectroscopic experiments, metal gaskets may attenuate the incident x-ray beam and emitted fluorescence x-rays, and the interaction of scattered radiation with the gasket may produce fluorescence that interferes with the x-ray spectrum of the sample. New arrangements and procedures were tested for the operation of the HDAC without using the metal gaskets. Distilled, de-ionized water was loaded into the sample chamber, a laser-milled recess 300 μm in diameter and ˜50 μm deep centered in the 1.0 mm face of the lower diamond anvil, and sealed by pressing the top diamond anvil face directly against the lower one without a metal gasket in between. A maximum sample pressure of 202 MPa at 617 °C was maintained for a duration of 10 min without evidence of leakage. A small change in fluid density was observed in one experiment where the sample was held at 266 MPa at 708 °C for 10 min. The gasketless HDAC was also employed in x-ray absorption spectroscopy experiments, where, in addition to the sample chamber in the lower diamond, two grooves were milled at a 90° angle to each other around the sample chamber to minimize the attenuation of incident and fluorescent x rays. With a minimum distance between the sample chamber and the grooves of 80 μm, a pressure of 76 MPa at 500 °C was maintained for 2 h with no change in the original fluid density.

  18. Containment of fluid samples in the hydrothermal diamond-anvil cell without the use of metal gaskets: Performance and advantages for in situ analysis

    USGS Publications Warehouse

    Chou, I.-Ming; Bassett, William A.; Anderson, Alan J.; Mayanovic, Robert A.; Shang, L.

    2008-01-01

    Metal gaskets (Re, Ir, Inconel, or stainless steel) normally used to contain fluid samples in the hydrothermal diamond-anvil cell (HDAC) are sometimes undesirable due to possible contamination and to gasket deformation at high pressures and temperatures resulting in nonisochoric behavior. Furthermore, in x-ray spectroscopic experiments, metal gaskets may attenuate the incident x-ray beam and emitted fluorescence x-rays, and the interaction of scattered radiation with the gasket may produce fluorescence that interferes with the x-ray spectrum of the sample. New arrangements and procedures were tested for the operation of the HDAC without using the metal gaskets. Distilled, de-ionized water was loaded into the sample chamber, a laser-milled recess 300 ??m in diameter and ???50 ??m deep centered in the 1.0 mm face of the lower diamond anvil, and sealed by pressing the top diamond anvil face directly against the lower one without a metal gasket in between. A maximum sample pressure of 202 MPa at 617 ??C was maintained for a duration of 10 min without evidence of leakage. A small change in fluid density was observed in one experiment where the sample was held at 266 MPa at 708 ??C for 10 min. The gasketless HDAC was also employed in x-ray absorption spectroscopy experiments, where, in addition to the sample chamber in the lower diamond, two grooves were milled at a 90?? angle to each other around the sample chamber to minimize the attenuation of incident and fluorescent x rays. With a minimum distance between the sample chamber and the grooves of 80 ??m, a pressure of 76 MPa at 500 ??C was maintained for 2 h with no change in the original fluid density. ?? 2008 American Institute of Physics.

  19. Containment of fluid samples in the hydrothermal diamond-anvil cell without the use of metal gaskets: performance and advantages for in situ analysis.

    PubMed

    Chou, I-Ming; Bassett, William A; Anderson, Alan J; Mayanovic, Robert A; Shang, Linbo

    2008-11-01

    Metal gaskets (Re, Ir, Inconel, or stainless steel) normally used to contain fluid samples in the hydrothermal diamond-anvil cell (HDAC) are sometimes undesirable due to possible contamination and to gasket deformation at high pressures and temperatures resulting in nonisochoric behavior. Furthermore, in x-ray spectroscopic experiments, metal gaskets may attenuate the incident x-ray beam and emitted fluorescence x-rays, and the interaction of scattered radiation with the gasket may produce fluorescence that interferes with the x-ray spectrum of the sample. New arrangements and procedures were tested for the operation of the HDAC without using the metal gaskets. Distilled, de-ionized water was loaded into the sample chamber, a laser-milled recess 300 microm in diameter and approximately 50 microm deep centered in the 1.0 mm face of the lower diamond anvil, and sealed by pressing the top diamond anvil face directly against the lower one without a metal gasket in between. A maximum sample pressure of 202 MPa at 617 degrees C was maintained for a duration of 10 min without evidence of leakage. A small change in fluid density was observed in one experiment where the sample was held at 266 MPa at 708 degrees C for 10 min. The gasketless HDAC was also employed in x-ray absorption spectroscopy experiments, where, in addition to the sample chamber in the lower diamond, two grooves were milled at a 90 degrees angle to each other around the sample chamber to minimize the attenuation of incident and fluorescent x rays. With a minimum distance between the sample chamber and the grooves of 80 microm, a pressure of 76 MPa at 500 degrees C was maintained for 2 h with no change in the original fluid density.

  20. Fluid pressure waves trigger earthquakes

    NASA Astrophysics Data System (ADS)

    Mulargia, Francesco; Bizzarri, Andrea

    2015-03-01

    Fluids-essentially meteoric water-are present everywhere in the Earth's crust, occasionally also with pressures higher than hydrostatic due to the tectonic strain imposed on impermeable undrained layers, to the impoundment of artificial lakes or to the forced injections required by oil and gas exploration and production. Experimental evidence suggests that such fluids flow along preferred paths of high diffusivity, provided by rock joints and faults. Studying the coupled poroelastic problem, we find that such flow is ruled by a nonlinear partial differential equation amenable to a Barenblatt-type solution, implying that it takes place in form of solitary pressure waves propagating at a velocity which decreases with time as v ∝ t [1/(n - 1) - 1] with n ≳ 7. According to Tresca-Von Mises criterion, these waves appear to play a major role in earthquake triggering, being also capable to account for aftershock delay without any further assumption. The measure of stress and fluid pressure inside active faults may therefore provide direct information about fault potential instability.

  1. Analysis of Direct Samples of Extraterrestrial, Organic-Bearing, Aqueous Fluids

    NASA Technical Reports Server (NTRS)

    Zolensky, Michael

    2016-01-01

    I will describe water we have found in 4.5 billion year old extraterrestrial salt, and the organics that are also present. We hypothesize that organics being carried through the parent body of the halite have been deposited adjacent to the fluid inclusions, where they have been preserved against any thermal metamorphism. We are making bulk compositional, carbon and hydrogen isotopic measurements of solid organic phases associated with the aqueous fluid inclusions in the meteorites. We will compare these organics with those found in chondrites and Wild-2 comet coma particles to determine whether these classes of organics had an origin within aqueous solutions.

  2. Collagenases in human synovial fluid

    PubMed Central

    Harris, Edward D.; DiBona, Donald R.; Krane, Stephen M.

    1969-01-01

    An enzyme which degrades native collagen at neutral pH has been isolated from cultures of rheumatoid synovium in vitro, but little or no collagenolytic activity has been found in homogenates of fresh rheumatoid synovium. Similar to most other mammalian collagenases this synovial enzyme is readily inhibited by serum proteins. Proteins of synovial fluid are derived largely from serum and synovial fluid from noninflamed joints was found to inhibit synovial collagenase; the inhibitor was destroyed by trypsin, but not by hyaluronidase. Inhibitory activity was reduced in approximately one-half of the fluids from patients with rheumatoid arthritis. In a total of nine synovial fluids, collagenolytic activity was detectable. This activity was not present in constant amounts in synovial fluids aspirated at different times from the same patient and tended to vary inversely with the titer of inhibitory proteins. The collagenolytic activity in the synovial fluids from different patients was variably inhibited by serum proteins. Two distinct collagenases were detected in some rheumatoid synovial fluids and separated by gel filtration. One, labeled “B” enzyme, with an estimated molecular weight 20,000-25,000 resembled the collagenase obtained from synovial cultures. The other, labeled “A” enzyme degraded collagen fibrils as well as collagen in solution. Disc electrophoresis on acrylamide gels and electron microscopy of segment long spacing (SLS) aggregates of reaction products of the enzymes at 27°C demonstrated that both “A” and “B” enzymes cleaved collagen molecules at a point three-quarters from the amino terminal end of the molecule. Thus collagen degradation in rheumatoid arthritis could result from the operation of these two collagenases. Images PMID:4309955

  3. Using oral fluids samples for indirect influenza A virus surveillance in farmed UK pigs.

    PubMed

    Gerber, Priscilla F; Dawson, Lorna; Strugnell, Ben; Burgess, Robert; Brown, Helen; Opriessnig, Tanja

    2017-02-01

    Influenza A virus (IAV) is economically important in pig production and has broad public health implications. In Europe, active IAV surveillance includes demonstration of antigen in nasal swabs and/or demonstration of antibodies in serum (SER) samples; however, collecting appropriate numbers of individual pig samples can be costly and labour-intensive. The objective of this study was to compare the probability of detecting IAV antibody positive populations using SER versus oral fluid (OF) samples. Paired pen samples, one OF and 5-14 SER samples, were collected cross-sectional or longitudinally. A commercial nucleoprotein (NP)-based blocking ELISA was used to test 244 OF and 1004 SER samples from 123 pens each containing 20-540 pigs located in 27 UK herds. Overall, the IAV antibody detection rate was higher in SER samples compared to OFs under the study conditions. Pig age had a significant effect on the probability of detecting positive pens. For 3-9-week-old pigs the probability of detecting IAV antibody positive samples in a pen with 95% confidence intervals was 40% (23-60) for OF and 61% (0.37-0.80) for SER ( P  =   0.04), for 10-14-week-old pigs it was 19% (8-40) for OF and 93% (0.71-0.99) for SER ( P  <   0.01), and for 18-20-week-old pigs it was 67% (41-85) for OF and 81% (0.63-0.91) for SER ( P  =   0.05). Collecting more than one OF sample in pens with more than 25 less than 18-week-old pigs should be further investigated in the future to elucidate the suitability of OF for IAV surveillance in herds with large pen sizes.

  4. Descriptions of therapeutic arthrocenthesis and of synovial fluid in a Nahuatl text from prehispanic Mexico.

    PubMed Central

    Alarcon-Segovia, D

    1980-01-01

    Paracelsus is considered to have been the first to record the viscid quality of the synovial fluid. However, his contemporary Bernardino de Sahagún, a Franciscan friar who came to Mexico shortly after the Spanish conquest, obtained from elderly Aztec Indians who spoke only Nahuatl the descriptions of therapeutic arthrocentesis and of the viscid nature of the synovial fluid. They compared the fluid from the knee joint to the viscid fluid from the leaves of the nopal cactus (Opuntia sp.). We here record their description and confirm the accuracy of their comparison. Images PMID:7416821

  5. Descriptions of therapeutic arthrocenthesis and of synovial fluid in a Nahuatl text from prehispanic Mexico.

    PubMed

    Alarcon-Segovia, D

    1980-06-01

    Paracelsus is considered to have been the first to record the viscid quality of the synovial fluid. However, his contemporary Bernardino de Sahagún, a Franciscan friar who came to Mexico shortly after the Spanish conquest, obtained from elderly Aztec Indians who spoke only Nahuatl the descriptions of therapeutic arthrocentesis and of the viscid nature of the synovial fluid. They compared the fluid from the knee joint to the viscid fluid from the leaves of the nopal cactus (Opuntia sp.). We here record their description and confirm the accuracy of their comparison.

  6. Measurements of C-reactive protein in serum and lactate dehydrogenase in serum and synovial fluid of patients with osteoarthritis.

    PubMed

    Hurter, K; Spreng, D; Rytz, U; Schawalder, P; Ott-Knüsel, F; Schmökel, H

    2005-03-01

    Diagnosis of osteoarthritis (OA) is based upon the clinical orthopaedic examination and the radiographic assessment, both of which can be non-specific and insensitive in early joint disease. The aim of our study was to investigate if there is an increase in serum levels of C-reactive protein (CRP) in degenerative joint disease (DJD) and if CRP could be used to help diagnose OA. We also wished to investigate whether it was possible to distinguish a joint with clinically and radiographically confirmed OA from a healthy joint by comparing lactate dehydrogenase (LDH) levels within the synovial fluid and the serum. We have shown a difference in synovial LDH levels between diseased and healthy joints (P<0.0001). There was also a significant difference between LDH in arthritic synovial fluid and serum, with no correlation between the values. Despite the fact that the values of our clinical patients tended to be higher than the values of our control group (P=0.05) all measured values were within the normal limits of previous publications. From these data, we conclude that single measurements of serum CRP do not permit detection of OA in clinical patients and that serum LDH is not a reliable marker for osteoarthritis. LDH levels in the synovial fluid could be of diagnostic value for identifying osteoarthritis.

  7. MRI features of cervical articular process degenerative joint disease in Great Dane dogs with cervical spondylomyelopathy.

    PubMed

    Gutierrez-Quintana, Rodrigo; Penderis, Jacques

    2012-01-01

    Cervical spondylomyelopathy or Wobbler syndrome commonly affects the cervical vertebral column of Great Dane dogs. Degenerative changes affecting the articular process joints are a frequent finding in these patients; however, the correlation between these changes and other features of cervical spondylomyelopathy are uncertain. We described and graded the degenerative changes evident in the cervical articular process joints from 13 Great Danes dogs with cervical spondylomyelopathy using MR imaging, and evaluated the relationship between individual features of cervical articular process joint degeneration and the presence of spinal cord compression, vertebral foraminal stenosis, intramedullary spinal cord changes, and intervertebral disc degenerative changes. Degenerative changes affecting the articular process joints were common, with only 13 of 94 (14%) having no degenerative changes. The most severe changes were evident between C4-C5 and C7-T1 intervertebral spaces. Reduction or loss of the hyperintense synovial fluid signal on T2-weighted MR images was the most frequent feature associated with articular process joint degenerative changes. Degenerative changes of the articular process joints affecting the synovial fluid or articular surface, or causing lateral hypertrophic tissue, were positively correlated with lateral spinal cord compression and vertebral foraminal stenosis. Dorsal hypertrophic tissue was positively correlated with dorsal spinal cord compression. Disc-associated spinal cord compression was recognized less frequently. © 2011 Veterinary Radiology & Ultrasound.

  8. Proinflammatory cytokine activities, matrix metalloproteinase-3 activity, and sulfated glycosaminoglycan content in synovial fluid of dogs with naturally acquired cranial cruciate ligament rupture.

    PubMed

    Fujita, Yukihiro; Hara, Yasushi; Nezu, Yoshinori; Schulz, Kurt S; Tagawa, Masahiro

    2006-06-01

    To measure and compare activities of interleukin-1beta (IL-1beta), interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha), and matrix metalloproteinase-3 (MMP-3); as well as sulfated glycosaminoglycan (S-GAG) content in synovial fluid from dogs with cranial cruciate ligament rupture (CCLR) and dogs with clinically normal stifles. To determine whether correlations exist between demographic and disease-related variables and these synovial markers. Prospective clinical study. Dogs with CCLR (n=23) and Beagles with normal stifle joints (n=21). Synovial fluid activities of proinflammatory cytokines (IL-1beta, IL-6, and TNF-alpha) were determined by bioassay. MMP-3 activity was measured using fluorogenic substrate. S-GAG contents were determined by dimethylmethylene blue dye-binding assay. Mann-Whitney U-test was used to compare results from CCLR joints with normal controls. Spearman's rank correlation test was used to evaluate associations between demographic and disease-related markers and synovial markers. Mean values for synovial markers were significantly higher in CCLR joints compared with controls. IL-1beta and MMP-3 were positively correlated with lameness duration. Activities of proinflammatory cytokines, MMP-3 activity and S-GAG contents were significantly elevated in synovial fluid from canine stifle joints with naturally acquired CCLR. These results indicate that there is joint inflammation and increased release of GAGs into synovial fluid, suggesting that these inflammatory changes are associated with depletion of proteoglycan from articular cartilage. Medical and surgical treatments designed to decrease joint inflammation and breakdown of proteoglycans may be of value in the management of CCLR in the dog.

  9. On the matter of synovial fluid lubrication: implications for Metal-on-Metal hip tribology.

    PubMed

    Myant, Connor; Cann, Philippa

    2014-06-01

    Artificial articular joints present an interesting, and difficult, tribological problem. These bearing contacts undergo complex transient loading and multi axes kinematic cycles, over extremely long periods of time (>10 years). Despite extensive research, wear of the bearing surfaces, particularly metal-metal hips, remains a major problem. Comparatively little is known about the prevailing lubrication mechanism in artificial joints which is a serious gap in our knowledge as this determines film formation and hence wear. In this paper we review the accepted lubrication models for artificial hips and present a new concept to explain film formation with synovial fluid. This model, recently proposed by the authors, suggests that interfacial film formation is determined by rheological changes local to the contact and is driven by aggregation of synovial fluid proteins. The implications of this new mechanism for the tribological performance of new implant designs and the effect of patient synovial fluid properties are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Signal intensity on fluid-attenuated inversion recovery images of condylar marrow changes correspond with slight pain in patients with temporomandibular joint disorders.

    PubMed

    Kodama, Sayaka; Otonari-Yamamoto, Mika; Sano, Tsukasa; Sakamoto, Junichirou; Imoto, Kenichi; Wakoh, Mamoru

    2014-01-01

    Edema and necrosis of the temporomandibular joint (TMJ) have been described in terms of bone marrow signal abnormalities in magnetic resonance imaging (MRI). However, painful joints often show no such signaling abnormalities, making the diagnosis of TMJ disorders difficult in the clinical setting. An association has been suggested between TMJ bone marrow change and TMJ pain, but even when such change results in slight pain, it may be too slight to be visually apparent on MR images. We hypothesized that fluid-attenuated inversion recovery (FLAIR) can be used to detect such minimal changes. The purpose of this study was to determine whether there is an association between signal intensity on FLAIR images and pain in the TMJ. The study included 85 TMJs in 45 patients referred to our department for MRI. The signal intensity on FLAIR images was measured. Pain was evaluated based on the visual analog scale. An unpaired t test and Pearson's product-moment correlation coefficient were used for the statistical analysis. A p value of <0.05 was considered statistically significant. Signal intensity on the FLAIR images was significantly higher in painful than in nonpainful TMJs, although a significant correlation was not observed between the signal intensity and the pain score. The results of this study suggest an association between abnormalities in the marrow of the mandibular condyle and pain. They also indicate that FLAIR imaging is a useful tool in the clinical diagnosis of painful TMJs.

  11. Design of a welded joint for robotic, on-orbit assembly of space trusses

    NASA Technical Reports Server (NTRS)

    Rule, W. K.; Thomas, F. P.

    1992-01-01

    A preliminary design for a weldable truss joint for on-orbit assembly of large space structures is described. The joint was designed for ease of assembly, for structural efficiency, and to allow passage of fluid (for active cooling or other purposes) along the member through the joint. The truss members were assumed to consist of graphite/epoxy tubes to which were bonded 2219-T87 aluminum alloy end fittings for welding on-orbit to truss nodes of the same alloy. A modified form of gas tungsten arc welding was assumed to be the welding process. The joint was designed to withstand the thermal and structural loading associated with a 120-ft diameter tetrahedral truss intended as an aerobrake for a mission to Mars.

  12. Design of a welded joint for robotic, on-orbit assembly of space trusses

    NASA Astrophysics Data System (ADS)

    Rule, W. K.; Thomas, F. P.

    1992-10-01

    A preliminary design for a weldable truss joint for on-orbit assembly of large space structures is described. The joint was designed for ease of assembly, for structural efficiency, and to allow passage of fluid (for active cooling or other purposes) along the member through the joint. The truss members were assumed to consist of graphite/epoxy tubes to which were bonded 2219-T87 aluminum alloy end fittings for welding on-orbit to truss nodes of the same alloy. A modified form of gas tungsten arc welding was assumed to be the welding process. The joint was designed to withstand the thermal and structural loading associated with a 120-ft diameter tetrahedral truss intended as an aerobrake for a mission to Mars.

  13. Temporomandibular joint and muscle disorder-type pain and comorbid pains in a national US sample.

    PubMed

    Plesh, Octavia; Adams, Sally H; Gansky, Stuart A

    2011-01-01

    To compare prevalences of self-reported comorbid headache, neck, back, and joint pains in respondents with temporomandibular joint and muscle disorder (TMJMD)-type pain in the 2000-2005 US National Health Interview Survey (NHIS), and to analyze these self-reported pains by gender and age for Non-Hispanic (NH) Whites (Caucasians), Hispanics, and NH Blacks (African Americans). Data from the 2000-2005 NHIS included information on gender, age, race, ethnicity, education, different common types of pain (specifically TMJMD-type, severe headache/migraine, neck, and low back pains), changes in health status, and health care utilization. Estimates and test statistics (ie, Pearson correlations, regressions, and logistic models) were conducted using SAS survey analysis and SUDAAN software that take into account the complex sample design. A total of 189,977 people (52% female and 48% males, 73% NH Whites, 12% Hispanic, 11% NH Blacks, and 4% "Other") were included. A total of 4.6% reported TMJMD-type pain, and only 0.77% overall reported it without any comorbid headache/migraine, neck, or low back pains; also 59% of the TMJMD-type pain (n = 8,964) reported ⋝ two comorbid pains. Females reported more comorbid pain than males (odds ratio [OR] = 1.41, P < .001); Hispanic and NH Blacks reported more than NH Whites (OR = 1.56, P <.001; OR= 1.38, P <.001, respectively). In addition, 53% of those with TMJMD-type pain had severe headache/migraines, 54% had neck pain, 64% low back pain, and 62% joint pain. Differences in gender and race by age patterns were detected. For females, headache/migraine pain with TMJMD-type pain peaked around age 40 and decreased thereafter regardless of race/ethnicity. Neck pain continued to increase up to about age 60, with a higher prevalence for Hispanic women at younger ages, and more pronounced in males, being the highest in the non-Whites. Low back pain was higher in Black and Hispanic females across the age span, and higher among non-White males

  14. The effect of robenacoxib on the concentration of C-reactive protein in synovial fluid from dogs with osteoarthritis

    PubMed Central

    2013-01-01

    Background Robenacoxib is a novel and highly selective inhibitor of COX-2 in dogs and cats and because of its acidic nature is regarded as being tissue-selective. Thirty four dogs with stifle osteoarthritis secondary to failure of the cranial cruciate ligament were recruited into this study. Lameness, radiographic features, synovial cytology and C-reactive protein concentrations in serum and synovial fluid were assessed before and 28 days after commencing a course of Robenacoxib at a dose of 1 mg/kg SID. Results There was a significant reduction in the lameness score (P < 0.01) and an increase in the radiographic score (P < 0.05) between pre- and post-treatment assessments. There was no difference between pre- (median 1.49 mg/l; Q1-Q3 0.56-4.24 mg/L) and post – (1.10 mg/L; 0.31-1.78 mg/L) treatment serum C-reactive protein levels although synovial fluid levels were significantly reduced (pre- : 0.44 mg/L; 0.23-1.62 mg/L; post- : 0.17 mg/L; 0.05-0.49 mg/L) (P < 0.05). There was no correlation between C-reactive protein concentrations in serum and matched synovial fluid samples. Conclusions Robenacoxib proved effective in reducing lameness in dogs with failure of the cranial cruciate ligament and osteoarthritis of the stifle joint. The drug also reduced levels of C-reactive protein in the synovial fluid taken from the affected stifle joint. Robenacoxib appears to reduce articular inflammation as assessed by C-reactive protein which supports the concept that Robenacoxib is a tissue-selective non-steroidal anti-inflammatory drug. PMID:23452411

  15. Fluorescence and UV-vis Spectroscopy of Synovial Fluids

    NASA Astrophysics Data System (ADS)

    Pinti, Marie J.; Stojilovic, Nenad; Kovacik, Mark W.

    2009-10-01

    Total joint arthroplasty involves replacing the worn cartilaginous surfaces of the joint with man-made materials that are designed to be biocompatible and to withstand mechanical stresses. Commonly these bearing materials consist of metallic alloys (TiAlV or CoCrMo) and UHMWPE. Following joint arthroplasty, the normal generation of micro-metallic wear debris particles that dislodge from the prosthesis has been shown to cause inflammatory aseptic osteolysis (bone loss) that ultimately results in the failure of the implant. Here we report our results on the novel use of Fluorescence and UV-vis spectroscopy to investigate the metallic content of synovial fluid specimens taken from postoperative total knee arthroplasties. Preliminary finding showed presence of alumina and chromium is some specimens. The ability to detect and monitor the wear rate of these implants could have far reaching implications in the prevention of metallic wear-debris induced osteolysis and impending implant failure.

  16. Collection of Oral Fluids Using Cotton Ropes as a Sampling Method to Detect Foot-and-Mouth Disease Virus Infection in Pigs.

    PubMed

    Vosloo, W; Morris, J; Davis, A; Giles, M; Wang, J; Nguyen, H T T; Kim, P V; Quach, N V; Le, P T T; Nguyen, P H N; Dang, H; Tran, H X; Vu, P P; Hung, V V; Le, Q T; Tran, T M; Mai, T M T; Le, Q T V; Singanallur, N B

    2015-10-01

    In high-density farming practices, it is important to constantly monitor for infectious diseases, especially diseases that have the potential to spread rapidly between holdings. Pigs are known to amplify foot-and-mouth disease (FMD) by excreting large amounts of virus, and it is therefore important to detect the virus quickly and accurately to minimize the spread of disease. Ropes were used to collect oral fluid samples from pigs, and each sample was compared to saliva samples collected from individual animals by detecting FMD virus RNA using real-time PCR. Two different experiments are described where groups of pigs were infected with different serotypes of FMD virus, either with or without vaccination, and unvaccinated pigs were kept in aerosol contact. The sensitivity of the rope sampling varied between 0.67 and 0.92, and the statistical agreement between this method and individual sampling ranged from substantial to moderate for the two different serotypes. The ease of collecting oral fluids using ropes together with the high sensitivity of subsequent FMD detection through PCR indicates that this could be a useful method to monitor pig populations for FMD virus infection. With further validation of the sensitivity of detection of FMD virus RNA, this can be a cost-effective, non-invasive diagnostic tool. © 2013 Blackwell Verlag GmbH.

  17. Corrosion resistance of a laser spot-welded joint of NiTi wire in simulated human body fluids.

    PubMed

    Yan, Xiao-Jun; Yang, Da-Zhi

    2006-04-01

    The purpose of this study was to investigate corrosion resistance of a laser spot-welded joint of NiTi alloy wires using potentiodynamic tests in Hank's solution at different PH values and the PH 7.4 NaCl solution for different Cl- concentrations. Scanning electron microscope observations were carried out before and after potentiodynamic tests. The composition of a laser spot-welded joint and base metal were characterized by using an electron probe microanalyzer. The results of potentiodynamic tests showed that corrosion resistance of a laser spot-welded joint of NiTi alloy wire was better than that of base metal, which exhibited a little higher breakdown potential and passive range, and a little lower passive current density. Corrosion resistances of a laser spot-welded joint and base metal decreased with increasing of the Cl- concentration and PH value. The improvement of corrosion resistance of the laser spot-welded joint was due to the decrease of the surface defects and the increase of the Ti/Ni ratio. (c) 2005 Wiley Periodicals, Inc.

  18. Periprosthetic joint infections: a clinical practice algorithm.

    PubMed

    Volpe, Luigi; Indelli, Pier Francesco; Latella, Leonardo; Poli, Paolo; Yakupoglu, Jale; Marcucci, Massimiliano

    2014-01-01

    periprosthetic joint infection (PJI) accounts for 25% of failed total knee arthroplasties (TKAs) and 15% of failed total hip arthroplasties (THAs). The purpose of the present study was to design a multidisciplinary diagnostic algorithm to detect a PJI as cause of a painful TKA or THA. from April 2010 to October 2012, 111 patients with suspected PJI were evaluated. The study group comprised 75 females and 36 males with an average age of 71 years (range, 48 to 94 years). Eighty-four patients had a painful THA, while 27 reported a painful TKA. The stepwise diagnostic algorithm, applied in all the patients, included: measurement of serum C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) levels; imaging studies, including standard radiological examination, standard technetium-99m-methylene diphosphonate (MDP) bone scan (if positive, confirmation by LeukoScan was obtained); and joint aspiration with analysis of synovial fluid. following application of the stepwise diagnostic algorithm, 24 out of our 111 screened patients were classified as having a suspected PJI (21.7%). CRP and ESR levels were negative in 84 and positive in 17 cases; 93.7% of the patients had a positive technetium-labeled bone scan, and 23% a positive LeukoScan. Preoperative synovial fluid analysis was positive in 13.5%; analysis of synovial fluid obtained by preoperative aspiration showed a leucocyte count of > 3000 cells μ/l in 52% of the patients. the present study showed that the diagnosis of PJI requires the application of a multimodal diagnostic protocol in order to avoid complications related to surgical revision of a misdiagnosed "silent" PJI. Level IV, therapeutic case series.

  19. Biochemical composition of fluids for amnioinfusion during fetoscopy.

    PubMed

    Adama van Scheltema, P N; In't Anker, P S; Vereecken, A; Vandenbussche, F P H A; Deprest, J A; Devlieger, R

    2008-01-01

    To evaluate which of the commercially available solutions is best suited for amnioinfusion during fetoscopy, based on resemblance with the biochemical properties of amniotic fluid. Amniotic fluid samples from 10 pregnancies were studied. Specimens were obtained from 5 pathologic pregnancies (of which 3 were complicated by polyhydramnios) and 5 uncomplicated pregnancies. The concentrations of sodium, potassium, chloride, bicarbonate, calcium, glucose, osmolality, pH, total protein content and albumin were determined in each sample. A literature search (PubMed, Embase) was performed to identify commercially available fluids used for amnioinfusion in clinical practice. The composition of these infusion solutions was compared to the amniotic fluid samples mentioned above. We identified two different electrolyte solutions used in clinical practice for amnioinfusion. We identified four additional commercially available solutions that could potentially be used for amnioinfusion. Most of these infusion solutions differ considerably from midtrimester amniotic fluid samples both in electrolyte composition and pH, with the most striking difference in the latter. Lactated Ringer's solution approximates amniotic fluid the closest for both electrolyte composition and pH. This infusion solution seems to be the most suitable choice for amnioinfusion during fetoscopy. (c) 2008 S. Karger AG, Basel.

  20. Recent advances in computational mechanics of the human knee joint.

    PubMed

    Kazemi, M; Dabiri, Y; Li, L P

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.

  1. MALDI-TOF MS performance compared to direct examination, culture, and 16S rDNA PCR for the rapid diagnosis of bone and joint infections.

    PubMed

    Lallemand, E; Coiffier, G; Arvieux, C; Brillet, E; Guggenbuhl, P; Jolivet-Gougeon, A

    2016-05-01

    The rapid identification of bacterial species involved in bone and joint infections (BJI) is an important element to optimize the diagnosis and care of patients. The aim of this study was to evaluate the usefulness of matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF MS) for the rapid diagnosis of bone infections, directly on synovial fluid (SF) or on crushed osteoarticular samples (CS). From January to October 2013, we prospectively analyzed 111 osteoarticular samples (bone and joint samples, BJS) from 78 patients in care at the University Hospital of Rennes, France. The diagnosis procedure leading to the sample collection was linked to a suspicion of infection, inflammatory disease, arthritis, or for any bone or joint abnormalities. Standard bacteriological diagnosis and molecular biology analysis [16S rRNA polymerase chain reaction (PCR) and sequencing] were conducted. In addition, analysis by MALDI-TOF MS was performed directly on the osteoarticular samples, as soon as the amount allowed. Culture, which remains the gold standard for the diagnosis of BJI, has the highest sensitivity (85.9 %) and remains necessary to test antimicrobial susceptibility. The 16S rDNA PCR results were positive in the group with positive BJI (28.6 %) and negative in the group without infection. Direct examination remains insensitive (31.7 %) but more effective than MALDI-TOF MS directly on the sample (6.3 %). The specificity was 100 % in all cases, except for culture (74.5 %). Bacterial culture remains the gold standard, especially enrichment in blood bottles. Direct analysis of bone samples with MALDI-TOF MS is not useful, possibly due to the low inoculum of BJS.

  2. MEASUREMENT OF PYRETHROID RESIDUES IN ENVIRONMENTAL AND FOOD SAMPLES BY ENHANCED SOLVENT EXTRACTION/SUPERCRITICAL FLUID EXTRACTION COUPLED WITH GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    The abstract summarizes pyrethorid methods development research. It provides a summary of sample preparation and analytical techniques such as supercritical fluid extraction, enhance solvent extraction, gas chromatography and tandem mass spectrometry.

  3. Surface sampling concentration and reaction probe

    DOEpatents

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  4. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    PubMed

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic

  5. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage.

    PubMed

    Mononen, Mika E; Jurvelin, Jukka S; Korhonen, Rami K

    2015-01-01

    Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.

  6. Insights on fluid-rock interaction evolution during deformation from fracture network geochemistry at reservoir-scale

    NASA Astrophysics Data System (ADS)

    Beaudoin, Nicolas; Koehn, Daniel; Lacombe, Olivier; Bellahsen, Nicolas; Emmanuel, Laurent

    2015-04-01

    Fluid migration and fluid-rock interactions during deformation is a challenging problematic to picture. Numerous interplays, as between porosity-permeability creation and clogging, or evolution of the mechanical properties of rock, are key features when it comes to monitor reservoir evolution, or to better understand seismic cycle n the shallow crust. These phenomenoms are especially important in foreland basins, where various fluids can invade strata and efficiently react with limestones, altering their physical properties. Stable isotopes (O, C, Sr) measurements and fluid inclusion microthermometry of faults cement and veins cement lead to efficient reconstruction of the origin, temperature and migration pathways for fluids (i.e. fluid system) that precipitated during joints opening or faults activation. Such a toolbox can be used on a diffuse fracture network that testifies the local and/or regional deformation history experienced by the rock at reservoir-scale. This contribution underlines the advantages and limits of geochemical studies of diffuse fracture network at reservoir-scale by presenting results of fluid system reconstruction during deformation in folded structures from various thrust-belts, tectonic context and deformation history. We compare reconstructions of fluid-rock interaction evolution during post-deposition, post-burial growth of basement-involved folds in the Sevier-Laramide American Rocky Mountains foreland, a reconstruction of fluid-rock interaction evolution during syn-depostion shallow detachment folding in the Southern Pyrenean foreland, and a preliminary reconstruction of fluid-rock interactions in a post-deposition, post-burial development of a detachment fold in the Appenines. Beyond regional specification for the nature of fluids, a common behavior appears during deformation as in every fold, curvature-related joints (related either to folding or to foreland flexure) connected vertically the pre-existing stratified fluid system

  7. Multielemental analysis of 18 essential and toxic elements in amniotic fluid samples by ICP-MS: Full procedure validation and estimation of measurement uncertainty.

    PubMed

    Markiewicz, B; Sajnóg, A; Lorenc, W; Hanć, A; Komorowicz, I; Suliburska, J; Kocyłowski, R; Barałkiewicz, D

    2017-11-01

    Amniotic fluid is the substantial factor in the development of an embryo and fetus due to the fact that water and solutes contained in it penetrate the fetal membranes in an hydrostatic and osmotic way as well as being swallowed by the fetus. Elemental composition of amniotic fluid influences the growth and health of the fetus, therefore, an analysis of amniotic fluid is important because the results would indicate abnormal levels of minerals or toxic elements. Inductively coupled plasma mass spectroscopy (ICP-MS) is often used for determination of trace and ultra-trace level elements in a wide range of matrices including biological samples because of its unique analytical capabilities. In the case of trace and ultra-trace level analysis detailed characteristics of analytical procedure as well as properties of the analytical result are particularly important. The purpose of this study was to develop a new analytical procedure for multielemental analysis of 18 elements (Al, As, Ba, Ca, Cd, Co, Cr, Cu, Mg, Mn, Ni, Pb, Sb, Se, Sr, U, V and Zn) in amniotic fluid samples using ICP-MS. Dynamic reaction cell (DRC) with two reaction gases, ammonia and oxygen, was involved in the experiment to eliminate spectral interferences. Detailed validation was conducted using 3 certified reference mterials (CRMs) and real amniotic fluid samples collected from patients. Repeatability for all analyzed analytes was found to range from 0.70% to 8.0% and for intermediate precision results varied from 1.3% to 15%. Trueness expressed as recovery ranged from 80% to 125%. Traceability was assured through the analyses of CRMs. Uncertainty of the results was also evaluated using single-laboratory validation approach. The obtained expanded uncertainty (U) results for CRMs, expressed as a percentage of the concentration of an analyte, were found to be between 8.3% for V and 45% for Cd. Standard uncertainty of the precision was found to have a greater influence on the combined standard uncertainty

  8. Impact of frequent cerebrospinal fluid sampling on Aβ levels: systematic approach to elucidate influencing factors.

    PubMed

    Van Broeck, Bianca; Timmers, Maarten; Ramael, Steven; Bogert, Jennifer; Shaw, Leslie M; Mercken, Marc; Slemmon, John; Van Nueten, Luc; Engelborghs, Sebastiaan; Streffer, Johannes Rolf

    2016-05-19

    Cerebrospinal fluid (CSF) amyloid-beta (Aβ) peptides are predictive biomarkers for Alzheimer's disease and are proposed as pharmacodynamic markers for amyloid-lowering therapies. However, frequent sampling results in fluctuating CSF Aβ levels that have a tendency to increase compared with baseline. The impact of sampling frequency, volume, catheterization procedure, and ibuprofen pretreatment on CSF Aβ levels using continuous sampling over 36 h was assessed. In this open-label biomarker study, healthy participants (n = 18; either sex, age 55-85 years) were randomized into one of three cohorts (n = 6/cohort; high-frequency sampling). In all cohorts except cohort 2 (sampling started 6 h post catheterization), sampling through lumbar catheterization started immediately post catheterization. Cohort 3 received ibuprofen (800 mg) before catheterization. Following interim data review, an additional cohort 4 (n = 6) with an optimized sampling scheme (low-frequency and lower volume) was included. CSF Aβ(1-37), Aβ(1-38), Aβ(1-40), and Aβ(1-42) levels were analyzed. Increases and fluctuations in mean CSF Aβ levels occurred in cohorts 1-3 at times of high-frequency sampling. Some outliers were observed (cohorts 2 and 3) with an extreme pronunciation of this effect. Cohort 4 demonstrated minimal fluctuation of CSF Aβ both on a group and an individual level. Intersubject variability in CSF Aβ profiles over time was observed in all cohorts. CSF Aβ level fluctuation upon catheterization primarily depends on the sampling frequency and volume, but not on the catheterization procedure or inflammatory reaction. An optimized low-frequency sampling protocol minimizes or eliminates fluctuation of CSF Aβ levels, which will improve the capability of accurately measuring the pharmacodynamic read-out for amyloid-lowering therapies. ClinicalTrials.gov NCT01436188 . Registered 15 September 2011.

  9. Action of polysaccharides of similar average mass but differing molecular volume and charge on fluid drainage through synovial interstitium in rabbit knees

    PubMed Central

    Scott, D; Coleman, P J; Mason, R M; Levick, J R

    2000-01-01

    Hyaluronan (HA), an anionic polysaccharide of synovial fluid, attenuates fluid loss from joints as joint pressure is raised (‘outflow buffering’). The buffering is thought to depend on the expanded molecular domain of the polymer, which causes reflection by synovial extracellular matrix, leading to flow-dependent concentration polarization. We therefore assessed the effects of polysaccharides of differing average molecular volume and charge. Trans-synovial fluid drainage(Q̇s) was measured at controlled joint fluid pressure (Pj) in knees of anaesthetized rabbits. The joints were infused with polydisperse HA of weight-average mass 2100 kDa (4 mg ml−1, n = 17), with polydisperse neutral dextran of similar average mass (2000 kDa; n = 7) or with Ringer solution vehicle (n = 2). The role of polymer charge was assessed by infusions of neutral or sulphated dextran of average molecular mass 500 kDa (n = 6). When HA was present, Q̇s increased little with pressure, forming a virtual plateau of ∼4 μl min−1 from 10 to 25 cmH2O. Neutral dextran 2000 failed to replicate this effect. Instead, Q̇s increased steeply with Pj, reaching eight times the HA value by 20 cmH2O (P = 0.0001, ANOVA). Dextran 2000 reduced flows in comparison with Ringer solution. Analysis of the aspirated joint fluid showed that 31 ± 0.07 % (s.e.m.) of dextran 2000 in the filtrand was reflected by synovium, compared with ≥ 79 % for HA. The viscometric molecular radius of the dextran, ∼31 nm, was smaller than that of HA (101–181 nm), as was its osmotic pressure. Anionic dextran 500 failed to buffer fluid drainage, but it reduced fluid escape and synovial conductance dQ̇s/dPj more than neutral dextran 500 (P < 0.0001, ANOVA). The anionic charge increased the molecular volume and viscosity of dextran 500. The results support the hypothesis that polymer molecular volume influences its reflection by interstitial matrix and outflow buffering. Polymer charge influences flow through an effect on

  10. Joint density-functional theory for energetics and spectroscopy in complex aqueous and nonaqueous solvents

    NASA Astrophysics Data System (ADS)

    Gunceler, Deniz

    Solvents are of great importance in many technological applications, but are difficult to study using standard, off-the-shelf ab initio electronic structure methods. This is because a single configuration of molecular positions in the solvent (a "snapshot" of the fluid) is not necessarily representative of the thermodynamic average. To obtain any thermodynamic averages (e.g. free energies), the phase space of the solvent must be sampled, typically using molecular dynamics. This greatly increases the computational cost involved in studying solvated systems. Joint density-functional theory has made its mark by being a computationally efficient yet rigorous theory by which to study solvation. It replaces the need for thermodynamic sampling with an effective continuum description of the solvent environment that is in-principle exact, computationally efficient and intuitive (easier to interpret). It has been very successful in aqueous systems, with potential applications in (among others) energy materials discovery, catalysis and surface science. In this dissertation, we develop accurate and fast joint density functional theories for complex, non-aqueous solvent enviroments, including organic solvents and room temperature ionic liquids, as well as new methods for calculating electron excitation spectra in such systems. These theories are then applied to a range of physical problems, from dendrite formation in lithium-metal batteries to the optical spectra of solvated ions.

  11. Spatially Detailed Porosity Prediction From Airborne Electromagnetics and Sparse Borehole Fluid Sampling

    NASA Astrophysics Data System (ADS)

    Macnae, J.; Ley-Cooper, Y.

    2009-05-01

    Sub-surface porosity is of importance in estimating fluid contant and salt-load parameters for hydrological modelling. While sparse boreholes may adequately sample the depth to a sub-horizontal water-table and usually also adequately sample ground-water salinity, they do not provide adequate sampling of the spatial variations in porosity or hydraulic permeability caused by spatial variations in sedimentary and other geological processes.. We show in this presentation that spatially detailed porosity can be estimated by applying Archie's law to conductivity estimates from airborne electromagnetic surveys with interpolated ground-water conductivity values. The prediction was tested on data from the Chowilla flood plain in the Murray-Darling Basin of South Australia. A frequency domain, helicopter-borne electromagnetic system collected data at 6 frequencies and 3 to 4 m spacings on lines spaced 100 m apart. This data was transformed into conductivity-depth sections, from which a 3D bulk-conductivity map could be created with about 30 m spatial resolution and 2 to 5 m vertical depth resolution. For that portion of the volume below the interpolated water-table, we predicted porosity in each cell using Archie's law. Generally, predicted porosities were in the 30 to 50 % range, consistent with expectations for the partially consolidated sediments in the floodplain. Porosities were directly measured on core from eight boreholes in the area, and compared quite well with the predictions. The predicted porosity map was spatially consistent, and when combined with measured salinities in the ground water, was able to provide a detailed 3D map of salt-loads in the saturated zone, and as such contribute to a hazard assessment of the saline threat to the river.

  12. Axisymmetric wave propagation in buried, fluid-filled pipes: effects of wall discontinuities

    NASA Astrophysics Data System (ADS)

    Muggleton, J. M.; Brennan, M. J.

    2005-03-01

    Water leakage from buried pipes is a subject of great concern in Britain and across the world because of decreasing water supplies due to changing rainfall patterns, deterioration of antiquated distribution systems, and an increasing population. Correlation techniques are widely used to locate the leaks, however, difficulties are encountered when repairs have been made to a pipe by inserting a new length of pipe to replace a damaged section. Although this practice is now discouraged, the new sections might be of a different material or possibly different cross-section or wall thickness. The wave propagation behaviour at such joints is poorly understood at present. In earlier work, simple expressions for the wavenumbers of the s=1 (fluid-dominated) and s=2 (shell dominated) axisymmetric wave types were derived for a fluid-filled elastic pipe, both in vacuo and surrounded by an elastic medium of infinite extent. In this paper, the wave transmission and reflection characteristics of these waves at an axisymmetric pipe wall discontinuity in a fluid-filled piping system are investigated theoretically. For changes in wall thickness or wall elasticity, simple expressions may be used to characterise the joint. The reason for this is that negligible energy conversion between the wavetypes occurs, so the wavetypes can be considered separately. For changes in the fluid cross-section, significant mode conversion occurs and the wavetypes must be considered together.

  13. Hyaluronan supplementation as a mechanical regulator of cartilage tissue development under joint-kinematic-mimicking loading.

    PubMed

    Wu, Yabin; Stoddart, Martin J; Wuertz-Kozak, Karin; Grad, Sibylle; Alini, Mauro; Ferguson, Stephen J

    2017-08-01

    Articular cartilage plays an essential role in joint lubrication and impact absorption. Through this, the mechanical signals are coupled to the tissue's physiological response. Healthy synovial fluid has been shown to reduce and homogenize the shear stress acting on the cartilage surfaces due to its unique shear-thinning viscosity. As cartilage tissues are sensitive to mechanical changes in articulation, it was hypothesized that replacing the traditional culture medium with a healthy non-Newtonian lubricant could enhance tissue development in a cartilage engineering model, where joint-kinematic-mimicking mechanical loading is applied. Different amounts of hyaluronic acid were added to the culture medium to replicate the viscosities of synovial fluid at different health states. Hyaluronic acid supplementation, especially at a physiologically healthy concentration (2.0 mg ml -1 ), promoted a better preservation of chondrocyte phenotype. The ratio of collagen II to collagen I mRNA was 4.5 times that of the control group, implying better tissue development (however, with no significant difference of measured collagen II content), with a good retention of collagen II and proteoglycan in the mechanically active region. Simulating synovial fluid properties by hyaluronic acid supplementation created a favourable mechanical environment for mechanically loaded constructs. These findings may help in understanding the influence of joint articulation on tissue homeostasis, and moreover, improve methods for functional cartilage tissue engineering. © 2017 The Author(s).

  14. Apparatus and Method for Time-integrated, Active Sampling of Contaminants in Fluids Demonstrated by Monitoring of Hexavalent Chromium in Groundwater

    PubMed Central

    Roll, Isaac B.; Driver, Erin M.; Halden, Rolf U.

    2016-01-01

    Annual U.S. expenditures of $2B for site characterization invite the development of new technologies to improve data quality while reducing costs and minimizing uncertainty in groundwater monitoring. This work presents a new instrument for time-integrated sampling of environmental fluids using in situ solid-phase extraction (SPE). The In Situ Sampler (IS2) is an automated submersible device capable of extracting dissolved contaminants from water (100s – 1000s mL) over extended periods (hours to weeks), retaining the analytes, and rejecting the processed fluid. A field demonstration of the IS2 revealed 28-day average concentration of hexavalent chromium in a shallow aquifer affected by tidal stresses via sampling of groundwater as both liquid and sorbed composite samples, each obtained in triplicate. In situ SPE exhibited 75 ± 6% recovery and an 8-fold improvement in reporting limit. Relative to use of conventional methods (100%), beneficial characteristics of the device and method included minimal hazardous material generation (2%), transportation cost (10%), and associated carbon footprint (2%). The IS2 is compatible with commercial SPE resins and standard extraction methods, and has been certified for more general use (i.e., inorganics and organics) by the Environmental Security Technology Certification Program (ESTCP) of the U.S. Department of Defense. PMID:26971208

  15. Comparison of supercritical fluid extraction and Soxhlet extraction for the determination of PCBs in seaweed samples.

    PubMed

    Punín Crespo, M O; Lage Yusty, M A

    2005-06-01

    The efficiency of supercritical fluid extraction for the determination of 12 polychlorinated biphenyls from algae samples is compared to Soxhlet extraction. Analytical detection limits for the individual congeners ranged from 0.62 microgl(-1) to 19 microgl(-1). Recovery was tested for both methods using standard addition procedure. At maximum spike level of concentration, the mean recoveries were not significantly different (P>0.05) of all PCBs studied, with the exception of PCBs 28, 52, 77 and 169. Method precision for Soxhlet extraction (< or =3.9%) was slightly better than for SFE (< or =9.2%). Although both methods yield comparable results, SFE offers the advantage of detecting all PCBs studied at lower concentrations, reducing extraction time, and reducing the amount of solvents needed. The optimized methods were applied to the analysis of three real seaweed samples, except for PCB101 the concentrations of all PCBs were low or below the detection limits. The levels of PCB101 found in sample 1 were 6.6+/-0.54 ng g(-1) d.w., in sample 2 the levels were 8.2+/-0.86 ng g(-1) d.w. and in sample 3 they were 7.7+/-0.08 ng g(-1) d.w.

  16. High-performance liquid chromatographic determination of histamine in biological samples: the cerebrospinal fluid challenge--a review.

    PubMed

    Wang, Zhaopin; Wu, Juanli; Wu, Shihua; Bao, Aimin

    2013-04-24

    Histamine, a neurotransmitter crucially involved in a number of basic physiological functions, undergoes changes in neuropsychiatric disorders. Detection of histamine in biological samples such as cerebrospinal fluid (CSF) is thus of clinical importance. The most commonly used method for measuring histamine levels is high performance liquid chromatography (HPLC). However, factors such as very low levels of histamine, the even lower CSF-histamine and CSF-histamine metabolite levels, especially in certain neuropsychiatric diseases, rapid formation of histamine metabolites, and other confounding elements during sample collection, make analysis of CSF-histamine and CSF-histamine metabolites a challenging task. Nonetheless, this challenge can be met, not only with respect to HPLC separation column, derivative reagent, and detector, but also in terms of optimizing the CSF sample collection. This review aims to provide a general insight into the quantitative analyses of histamine in biological samples, with an emphasis on HPLC instruments, methods, and hyphenated techniques, with the aim of promoting the development of an optimal and practical protocol for the determination of CSF-histamine and/or CSF-histamine metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Fault fluid evolution at the outermost edges of the southern Apennines fold-and-thrust belt, Italy

    NASA Astrophysics Data System (ADS)

    Agosta, Fabrizio; Belviso, Claudia; Cavalcante, Francesco; Vita Petrullo, Angela

    2017-04-01

    This work focuses on the structural architecture and mineralization of a high-angle, extensional fault zone that crosscuts the Middle Pleistocene tuffs and pyroclastites of the Vulture Volcano, southern Italy. This fault zone is topped by a few m-thick travertine deposit formed by precipitation, in a typical lacustrine depositional environment, from a fault fluid that included a mixed, biogenic- and mantle-derived CO2. The detailed analysis of its different mineralization can shed new lights into the shallow crustal fluid flow that took place during deformation of the outer edge of the southern Apennines fold-and-thrust belt. In fact, the study fault zone is interpreted as a shallow-seated, tear fault associated with a shallow thrust fault displacing the most inner portion of the Bradano foredeep basin infill, and was thus active during the latest stages of contractional deformation. Far from the fault zone, the fracture network is made up of three high-angle joint sets striking N-S, E-W and NW-SE, respectively. The former two sets can be interpreted as the older structural elements that pre-dated the latter one, which is likely due to the current stress state that affects the whole Italian peninsula. In the vicinity of the fault zone, a fourth joint high-angle set striking NE-SW is also present, which becomes the most dominant fracture set within the study footwall fault damage zone. Detailed X-ray diffraction analysis of the powder obtained from hand specimens representative of the multiple mineralization present within the fault zone, and in the surrounding volcanites, are consistent with circulation of a fault fluid that modified its composition with time during the latest stages of volcanic activity and contractional deformation. Specifically, veins infilled with and slickenside coated by jarosite, Opal A and/or goethite are found in the footwall fault damage zone. Based upon the relative timing of formation of the aforementioned joint sets, deciphered after

  18. Acute phase protein haptoglobin as inflammatory marker in serum and synovial fluid in an equine model of arthritis.

    PubMed

    Barrachina, Laura; Remacha, Ana Rosa; Soler, Lourdes; García, Natalia; Romero, Antonio; Vázquez, Francisco José; Vitoria, Arantza; Álava, María Ángeles; Lamprave, Fermín; Rodellar, Clementina

    2016-12-01

    Acute phase proteins are useful inflammatory markers in horses. Haptoglobin (Hp) serum level is increased in horses undergoing different inflammatory processes, including arthritis. However, Hp concentration has not been assessed in inflammatory synovial fluid (SF). The aim of the present study was to investigate the Hp response in serum and SF in horses undergoing experimentally induced arthritis. For this purpose, serum and SF samples were collected from 12 animals before amphotericin B-induced arthritis was created (T0, healthy) and 15days after the lesion induction (T1, joint inflammation) and Hp was determined by single radial immunodiffusion. The Hp increase between T0 and T1 was significant in both serum and SF, and serum Hp concentration at T0 was significantly higher than in SF, but significant differences were not found at T1, indicating a higher Hp increase in SF. A significant positive correlation for Hp concentration between serum and SF samples was found. These results highlight the potential usefulness of Hp as inflammatory marker in horses, showing for the first time the increase of Hp in SF from joint inflammation in the horse. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Diagnosis at a glance of biological non-Newtonian fluids with Film Interference Flow Imaging (FIFI)

    NASA Astrophysics Data System (ADS)

    Hidema, R.; Yamada, N.; Furukawa, H.

    2012-04-01

    In the human body, full of biological non-Newtonian fluids exist. For example, synovial fluids exist in our joints, which contain full of biopolymers, such as hyaluronan and mucin. It is thought that these polymers play critical roles on the smooth motion of the joint. Indeed, luck of biopolymers in synovial fluid cause joint pain. Here we study the effects of polymer in thin liquid layer by using an original experimental method called Film Interference Flow Imaging (FIFI). A vertically flowing soap film containing polymers is made as two-dimensional flow to observe turbulence. The thickness of water layer is about 4 μm sandwiched between surfactant mono-layers. The interference pattern of the soap film is linearly related to the flow velocity in the water layer through the change in the thickness of the film. Thus the flow velocity is possibly analyzed by the single image analysis of the interference pattern, that is, FIFI. The grid turbulence was made in the flowing soap films containing the long flexible polymer polyethyleneoxide (PEO, Mw=3.5x106), and rigid polymer hydroxypropyl cellulose (HPC, Mw > 1.0 x106). The decaying process of the turbulence is affected by PEO and HPC at several concentrations. The effects of PEO are sharply seen even at low concentrations, while the effects of HPC are gradually occurred at much higher concentration compared to the PEO. It is assumed that such a difference between PEO and HPC is due to the polymer stretching or polymer orientation under turbulence, which is observed and analyzed by FIFI. We believe the FIFI will be applied in the future to examine biological fluids such as synovial fluids quickly and quantitatively.

  20. Temporo mandibular joint ankylosis.

    PubMed

    Vasconcelos, Belmiro Cavalcanti do Egito; Porto, Gabriela Granja; Bessa-Nogueira, Ricardo Viana

    2008-01-01

    Ankylosis may be defined as joint surfaces fusion. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high recurrence rate. The aim of this study is to report six cases treated by joint reconstruction, evaluate the results of these surgeries and review the literature. The sample in this retrospective study was obtained from the records of the university hospital, patients who had to undergo ankylosis treatment by alloplastic or autogenous graft between March 2001 and October 2005. Pre - and post-operative assessment included a throughout history and physical examination to determine the cause of ankylosis, the Maximum mouth opening (MMO), etiology and type of ankylosis, recurrence rate and presence of facial nerve paralysis. The mean MMO in the pre-operative period was 9.6 mm (0 mm to 17 mm) and in the post-operative period it was of 31.33 mm (14 mm to 41 mm), there was no facial nerve paralysis and there was recurrence in just one case. The joint reconstruction with alloplastic or autogenous grafts for the ankylosis treatment proved to be efficient in relation to the post-operative MMO, recurrence and joint function.

  1. Comparison of the effects of caudal pole hemi-meniscectomy and complete medial meniscectomy in the canine stifle joint.

    PubMed

    Johnson, K A; Francis, D J; Manley, P A; Chu, Q; Caterson, B

    2004-08-01

    To compare the effects of caudal pole hemi-meniscectomy (CPHM) and complete medial meniscectomy (MM), specifically with respect to development of secondary osteoarthritis, in the stifle joints of clinically normal dogs. 14 large-breed dogs. Unilateral CPHM (7 dogs) or MM (7) was performed, and the left stifle joints served as untreated control joints. Gait was assessed in all dogs before surgery and at 4, 8, 12, and 16 weeks postoperatively. After euthanasia, joints were evaluated grossly; Mankin cartilage scores, subchondral bone density assessment, and articular cartilage proteoglycan extraction and western blot analyses of 3B3(-) and 7D4 epitopes were performed. Weight distribution on control limbs exceeded that of treated limbs at 4 and 16 weeks after surgery in the CPHM group and at 4 and 8 weeks after surgery in the MM group; weight distribution was not significantly different between the 2 groups. After 16 weeks, incomplete meniscal regeneration and cartilage fibrillation on the medial aspect of the tibial plateau and medial femoral condyle were detected in treated joints in both groups. Mankin cartilage scores, subchondral bone density, and immunoexpression of 3B3(-) or 7D4 in articular cartilage in CPHM- or MM-treated joints were similar; 7D4 epitope concentration in synovial fluid was significantly greater in the MM-treated joints than in CPHM-treated joints. Overall severity of secondary osteoarthritis induced by CPHM and MM was similar. Investigation of 7D4 epitope concentration in synovial fluid suggested that CPHM was associated with less disruption of chondrocyte metabolism.

  2. Determination of the Landau Lifshitz damping parameter of composite magnetic fluids

    NASA Astrophysics Data System (ADS)

    Fannin, P. C.; Malaescu, I.; Marin, C. N.

    2007-01-01

    Measurements of the frequency dependent, complex magnetic susceptibility, χ(ω)= χ‧( ω)- iχ″( ω), in the GHz range, are used to investigate the effect which the mixing of two different magnetic fluids has on the value of the damping parameter, α, of the Landau-Lifshitz equation. The magnetic fluid samples investigated in this study were three kerosene-based magnetic fluids, stabilised with oleic acid, denoted as MF1, MF2 and MF3. Sample MF1 was a magnetic fluid with Mn 0.6Fe 0.4Fe 2O 4 particles, sample MF2 was a magnetic fluid with Ni 0.4Zn 0.6Fe 2O 4 particles and sample MF3 was a composite magnetic fluid obtained by mixing a part of sample MF1 with a part of sample MF2, in proportion of 1:1. The experimental results revealed that the value of the damping parameter of the composite sample (sample MF3) is between the α values obtained for its constituents (samples MF1 and MF2). Based on the superposition principle, which states that the susceptibility of a magnetic fluid sample is a superposition of individual contributions of the magnetic particles, a theoretical model is proposed. The experimental results are shown to be in close agreement with the theoretical results. This result is potentially useful in the design of microwave-operating materials, in that it enables one to determine a particular value of damping parameter.

  3. Changes of synovial fluid protein concentrations in supra-patellar bursitis patients after the injection of different molecular weights of hyaluronic acid.

    PubMed

    Chen, Carl P C; Hsu, Chih Chin; Pei, Yu-Cheng; Chen, Ruo Li; Zhou, Shaobo; Shen, Hsuan-Chen; Lin, Shih-Cherng; Tsai, Wen Chung

    2014-04-01

    Knee pain is commonly seen in orthopedic and rehabilitation outpatient clinical settings, and in the aging population. Bursitis of the knee joint, especially when the volume of the synovial fluid is large enough, can compress and distend the nearby soft tissues, causing pain in the knee joint. Out of all the bursae surrounding the knee joint, supra-patellar bursitis is most often associated with knee pain. Treatment strategies in managing supra-patellar bursitis include the aspiration of joint synovial fluid and then followed by steroid injection into the bursa. When supra-patellar bursitis is caused by degenerative disorders, the concept of viscosupplementation treatment may be effective by injecting hyaluronic acid into the bursa. However, the rheology or the changes in the concentrations of proteins (biomarkers) that are related to the development of bursitis in the synovial fluid is virtually unexplored. Therefore, this study aimed to identify the concentration changes in the synovial fluid total protein amount and individual proteins associated with supra-patellar bursitis using the Bradford protein assay and western immunoglobulin methods. A total of 20 patients were divided into two groups with 10 patients in each group. One group received the high molecular weight hyaluronic acid product of Synvisc Hylan G-F 20 and the other group received the low molecular weight hyaluronic acid product of Hya-Joint Synovial Fluid Supplement once per week injection into the bursa for a total of 3 weeks. Significant decreases in the synovial fluid total protein concentrations were observed after the second dosage of high molecular weight hyaluronic acid injections. Apolipoprotein A-I, interleukin 1 beta, alpha 1 antitrypsin, and matrix metalloproteinase 1 proteins revealed a trend of decreasing western immunoblotting band densities after hyaluronic acid injections. The decreases in apolipoprotein A-I and interleukin 1 beta protein band densities were significant in the high

  4. Is Xpert MTB/RIF appropriate for diagnosing tuberculous pleurisy with pleural fluid samples? A systematic review.

    PubMed

    Huo, Zhen-Yu; Peng, Li

    2018-06-25

    Tuberculous pleurisy (TP) presents a diagnostic problem due to the limitations of traditional diagnostic methods. Different studies with the Xpert MTB/RIF assay have drawn variable conclusions about its values in TP diagnosis. We conducted a meta-analysis to assess whether the Xpert MTB/RIF assay is appropriate for the diagnosis of TP using pleural fluid samples. A systematic search of four literature databases in English and Chinese language was performed to identify studies involving the use of Xpert MTB/RIF in patients with TP confirmed by plural biopsy and/or mycobacterial culture. Pooled sensitivity, specificity and accordance proportion were calculated, and the forest plots were generated to assess the accuracy of Xpert MTB/RIF for TP diagnosis. We identified 23 studies meeting our inclusion criteria. The pooled sensitivity and specificity of Xpert MTB/RIF were 30% (95% CI: 21-42%, I 2  = 87.93%) and 99% (95% CI: 97-100%, I 2  = 96.20%), respectively, and the area under the SROC curve (AUC) of Xpert MTB/RIF was 0.86 (95% CI: 0.83-0.89). Compared with drug susceptibility testing (DST), the pooled accordance rate of Xpert MTB/RIF in detecting rifampicin-susceptible cases and rifampicin-resistant cases was 99% (95% CI: 95-104%, I 2  = 8.7%) and 94% (95% CI: 86-102%), respectively. Our analysis suggests that the Xpert MTB/RIF assay is of limited value as a screening test for TP but has a high potential for confirming TP diagnosis and differentiating TP from non-TB diseases using pleural fluid samples.

  5. MicroRNA Expression Profile in the Prenatal Amniotic Fluid Samples of Pregnant Women with Down Syndrome.

    PubMed

    Karaca, Emin; Aykut, Ayça; Ertürk, Biray; Durmaz, Burak; Güler, Ahmet; Büke, Barış; Yeniel, Ahmet Özgür; Ergenoğlu, Ahmet Mete; Özkınay, Ferda; Özeren, Mehmet; Kazandı, Mert; Akercan, Fuat; Sağol, Sermet; Gündüz, Cumhur; Çoğulu, Özgür

    2018-03-15

    Down syndrome, which is the most common human chromosomal anomaly that can affect people of any race and age, can be diagnosed prenatally in most cases. Prenatal diagnosis via culture method is time-consuming; thus, genetic analysis has thus been introduced and is continually being developed for rapid prenatal diagnosis. For this reason, the effective use of microRNA profiling for the rapid analysis of prenatal amniotic fluid samples for the diagnosis of Down syndrome was investigated. To evaluate the expression levels of 14 microRNAs encoded by chromosome 21 in amniotic fluid samples and their utility for prenatal diagnosis of Down syndrome. Case-control study. We performed invasive prenatal testing for 56 pregnant women; 23 carried fetuses with Down syndrome, and 33 carried fetuses with a normal karyotype. Advanced maternal age and increased risk for Down syndrome in the screening tests were indications for invasive prenatal testing. The age of gestation in the study and control groups ranged between 17 and 18 weeks. The expression levels of microRNA were measured by real-time polymerase chain reaction. The expression levels of microRNA-125b-2, microRNA-155 , and microRNA-3156 were significantly higher in the study group than in the control group. The presence of significantly dysregulated microRNAs may be associated with either the phenotype or the result of abnormal development. Further large-scale comparative studies conducted in a variety of conditions may bring novel insights in the field of abnormal prenatal conditions.

  6. The effects of transcutaneous electrical nerve stimulation on joint position sense in patients with knee joint osteoarthritis.

    PubMed

    Shirazi, Zahra Rojhani; Shafaee, Razieh; Abbasi, Leila

    2014-10-01

    To study the effects of transcutaneous electrical nerve stimulation (TENS) on joint position sense (JPS) in knee osteoarthritis (OA) subjects. Thirty subjects with knee OA (40-60 years old) using non-random sampling participated in this study. In order to evaluate the absolute error of repositioning of the knee joint, Qualysis Track Manager system was used and sensory electrical stimulation was applied through the TENS device. The mean errors in repositioning of the joint, in two position of the knee joint with 20 and 60 degree angle, after applying the TENS was significantly decreased (p < 0.05). Application of TENS in subjects with knee OA could improve JPS in these subjects.

  7. Magnetic Capture of a Molecular Biomarker from Synovial Fluid in a Rat Model of Knee Osteoarthritis

    PubMed Central

    Yarmola, Elena G.; Shah, Yash; Arnold, David P.; Dobson, Jon; Allen, Kyle D.

    2015-01-01

    Biomarker development for osteoarthritis (OA) often begins in rodent models, but can be limited by an inability to aspirate synovial fluid from a rodent stifle (similar to the human knee). To address this limitation, we have developed a magnetic nanoparticle-based technology to collect biomarkers from a rodent stifle, termed magnetic capture. Using a common OA biomarker - the c-terminus telopeptide of type II collagen (CTXII) - magnetic capture was optimized in vitro using bovine synovial fluid and then tested in a rat model of knee OA. Anti-CTXII antibodies were conjugated to the surface of superparamagnetic iron oxide-containing polymeric particles. Using these anti-CTXII particles, magnetic capture was able to estimate the level of CTXII in 25 µL aliquots of bovine synovial fluid; and under controlled conditions, this estimate was unaffected by synovial fluid viscosity. Following in vitro testing, anti-CTXII particles were tested in a rat monoiodoacetate model of knee OA. CTXII could be magnetically captured from a rodent stifle without the need to aspirate fluid and showed 10 fold changes in CTXII levels from OA-affected joints relative to contralateral control joints. Combined, these data demonstrate the ability and sensitivity of magnetic capture for post-mortem analysis of OA biomarkers in the rat. PMID:26136062

  8. Magnetic Capture of a Molecular Biomarker from Synovial Fluid in a Rat Model of Knee Osteoarthritis.

    PubMed

    Yarmola, Elena G; Shah, Yash; Arnold, David P; Dobson, Jon; Allen, Kyle D

    2016-04-01

    Biomarker development for osteoarthritis (OA) often begins in rodent models, but can be limited by an inability to aspirate synovial fluid from a rodent stifle (similar to the human knee). To address this limitation, we have developed a magnetic nanoparticle-based technology to collect biomarkers from a rodent stifle, termed magnetic capture. Using a common OA biomarker--the c-terminus telopeptide of type II collagen (CTXII)--magnetic capture was optimized in vitro using bovine synovial fluid and then tested in a rat model of knee OA. Anti-CTXII antibodies were conjugated to the surface of superparamagnetic iron oxide-containing polymeric particles. Using these anti-CTXII particles, magnetic capture was able to estimate the level of CTXII in 25 μL aliquots of bovine synovial fluid; and under controlled conditions, this estimate was unaffected by synovial fluid viscosity. Following in vitro testing, anti-CTXII particles were tested in a rat monoiodoacetate model of knee OA. CTXII could be magnetically captured from a rodent stifle without the need to aspirate fluid and showed tenfold changes in CTXII levels from OA-affected joints relative to contralateral control joints. Combined, these data demonstrate the ability and sensitivity of magnetic capture for post-mortem analysis of OA biomarkers in the rat.

  9. Experimental Evidence of Volcanic Earthquakes Induced by Different Fluid Types

    NASA Astrophysics Data System (ADS)

    Clarke, J. A.; Adam, L.; Sarout, J.; van Wijk, K.; Dautriat, J. D.; Kennedy, B.

    2017-12-01

    Low Frequency volcanic seismicity has long been associated with resonance in fluid-filled cracks or conduits driven by pressure perturbations at depth. In volcano monitoring, fluid movement, fracturing and the conduit geometry are interpreted based on field observations, laboratory experiments, and numerical models. Fluids in a volcanic environment include gasses, brine and magmas with different viscosities. Magma viscosity is a key influence on eruptive behaviour. For example, increasing magma viscosity is known to favour explosive eruptions. How different fluids affect volcano seismicity is not well understood. Here, we explore the effects of fluid type on volcano seismic signals. Frequency content in the signal, frequency of the events, source mechanism and quality factor are studied. We simulate volcano tectonic (fracturing) and volcano seismic (fluid movement) signatures in a controlled laboratory environment using a range of rock samples, fluid types and pressure conditions. The viscosity of the fluids spans six orders of magnitude, representing realistic volcanic fluids. Microseismicity is generated by venting pressurised fluids through pre-generated fracture networks in cylindrical rock core samples and detected by an array of 18 ultrasonic transducers. We fracture samples of two lithologies: 1) low porosity impermeable granite samples and 2) a permeable volcanic ash tuff sample. Permeability and porosity in the granites are due to a fracture network, while in the tuff a high porosity matrix ( 40 %) and a fracture network interact. The fluids used are nitrogen gas, water, and mixtures of water and glycerol. We generate and detect a myriad of seismic event types, some of which resemble well-known families of volcano-tectonic, low-frequency, hybrid and tremor-type seismicity. Samples with fluids of lower density and viscosity generate a higher number of seismic events. We will present an integrated analysis of the event types, frequency content, source

  10. Development of a split-flow system for high precision variable sample introduction in supercritical fluid chromatography.

    PubMed

    Sakai, Miho; Hayakawa, Yoshihiro; Funada, Yasuhiro; Ando, Takashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2017-09-15

    In this study, we propose a novel variable sample injection system based on full-loop injection, named the split-flow sample introduction system, for application in supercritical fluid chromatography (SFC). In this system, the mobile phase is split by the differential pressure between two back pressure regulators (BPRs) after full-loop injection suitable for SFC, and this differential pressure determines the introduction rate. Nine compounds with a wide range of characteristics were introduced with high reproducibility and universality, confirming that a robust variable sample injection system was achieved. We also investigated the control factors of our proposed system. Sample introduction was controlled by the ratio between the column-side pressure drops in splitless and split flow, ΔP columnsideinsplitless and ΔP columnsideinsplit , respectively, where ΔP columnsideinsplitless is related to the mobile phase flow rate and composition and the column resistance. When all other conditions are kept constant, increasing the make-up flow induces an additional pressure drop on the column side of the system, which leads to a reduced column-side flow rate, and hence decreased the amount of sample injected, even when the net pressure drop on the column side remains the same. Thus, sample introduction could be highly controlled at low sample introduction rate, regardless of the introduction conditions. This feature is advantageous because, as a control factor, the solvent in the make-up pump is independent of the column-side pressure drop. Copyright © 2017. Published by Elsevier B.V.

  11. The spring ligament recess of the talocalcaneonavicular joint: depiction on MR images with cadaveric and histologic correlation.

    PubMed

    Desai, Kapil R; Beltran, Luis S; Bencardino, Jenny T; Rosenberg, Zehava S; Petchprapa, Catherine; Steiner, German

    2011-05-01

    The objective of this study was to describe the anatomy and MR appearance of the spring ligament recess of the talocalcaneonavicular joint. Forty-nine MR examinations of the ankle with a spring ligament recess were prospectively collected. The size of the recess was measured. The presence of the following variables was recorded: talocalcaneonavicular joint effusion, ankle joint effusion, talar head impaction, acute lateral ankle sprain, chronic lateral ankle sprain, spring ligament tear, sinus tarsi ligament tear, talar dome osteochondral injury, and talonavicular osteoarthrosis. The Fisher exact test was performed to quantify the association of the talocalcaneonavicular effusion with the other variables. MR arthrography and dissection with histologic analysis were performed in two cadaveric ankles. Twenty-four men and 25 women (average age, 39 years; range, 21-77 years) were included in the study. The average size of the fluid collection was 0.4 × 0.8 cm (range, 0.2-0.9 × 0.4-1.5 cm). The prevalence of the measured variables was talocalcaneonavicular joint effusion, 67.3%; ankle joint effusion, 61.2%; talar head impaction, 32.7%; acute lateral ankle sprain, 28.6%; chronic lateral ankle sprain, 59.2%; spring ligament tear, 14.3%; sinus tarsi ligament tear, 12.2%; talar dome osteochondral lesion, 20.4%; and talonavicular osteoarthrosis, 18.4%. There was a higher prevalence of talar head impaction among individuals with talocalcaneonavicular joint effusion (p = 0.0522). Cadaveric study revealed communication between the talocalcaneonavicular joint and the spring ligament recess. The spring ligament recess is a synovium-lined, fluid-filled space that communicates with the talocalcaneonavicular joint. The recess should be distinguished from a tear of the plantar components of the spring ligament.

  12. Recent Advances in Computational Mechanics of the Human Knee Joint

    PubMed Central

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  13. Leukocyte Esterase as a Biomarker in the Diagnosis of Periprosthetic Joint Infection.

    PubMed

    Wang, Chi; Li, Rui; Wang, Qi; Duan, Jinyan; Wang, Chengbin

    2017-01-21

    BACKGROUND Total joint arthroplasty (TJA) has been one of the most rewarding interventions for treating patients suffering from joint disorders. However, periprosthetic joint infection (PJI) is a serious complication that frequently accompanies TJA. Our study aimed to investigate the application of the leukocyte esterase (LE) strip in the diagnosis of PJI. MATERIAL AND METHODS From October 2014 to July 2015, 72 patients who had undergone joint puncture after arthroplasty in our hospital were enrolled in this trial. One drop of synovial fluid from each available patient was applied to the LE strip, and the results were observed after 1-3 min. If the color turned to dark purple, we recognized this as a positive result, while other colors were regarded as negative results. Centrifugation was used when the synovial fluid was mixed with blood. The Musculoskeletal Infection Society (MSIS) definition was used as the standard reference to identify whether PJI was found in patients or not. The results of diagnosis and LE strips test were compared, and indicators reflecting diagnostic value were calculated. Correlation of the LE data with erythrocyte sedimentation rate (ESR), elevated C-reactive protein (CRP), synovial white blood cell (WBC) counts, and polymorphonuclear neutrophil (PMN) percentage was calculated. RESULTS By MSIS criteria, 38 patients were diagnosed with PJI and 34 patients were not infected. Two types of LE strip presented the same results with sensitivity of 84.21% (95% confidence interval [CI]: 68.75~93.98%), specificity of 97.06% (95% CI: 84.67~99.93%), positive predictive value (PPV) of 96.97% (95% CI: 84.24~99.92%), and negative predictive value (NPV) of 84.62% (95% CI: 69.47~94.14%). There were one false-positive case and six false-negative cases in this trial. There is a strong correlation between LE strip and synovial fluid PMN percentage. CONCLUSIONS The sensitivity and specificity of the LE strip in the diagnosis of PJI are quite high, which means

  14. Age-related changes in the articular cartilage of the stifle joint in non-working and working German Shepherd dogs.

    PubMed

    Francuski, J V; Radovanović, A; Andrić, N; Krstić, V; Bogdanović, D; Hadzić, V; Todorović, V; Lazarević Macanović, M; Sourice Petit, S; Beck-Cormier, S; Guicheux, J; Gauthier, O; Kovacević Filipović, M

    2014-11-01

    The aims of this study were to define age-related histological changes in the articular cartilage of the stifle joint in non-chondrodystrophic dogs and to determine whether physical activity has a positive impact on preservation of cartilage structure during ageing. Twenty-eight German shepherd dogs were included in the study. These dogs had no evidence of joint inflammation as defined by clinical assessment, radiology and synovial fluid analysis (specifically absence of synovial fluid serum amyloid A). The dogs were grouped as young working (n ¼ 4), young non-working (n ¼ 5), aged working (n ¼ 13) and aged non-working (n ¼ 6) animals. Gross changes in the stifle joints were recorded and biopsy samples of femoral and tibial articular cartilage were evaluated for thickness; chondrocyte number, density, surface area and morphology; isogenous group morphology; tidemark integrity; subchondral bone structure; presence of proteoglycans/ glycosaminoglycans; and expression of type I, II and X collagens. The major age-related changes, not related to type of physical activity, included elevated chondrocyte density and thinning of tibial cartilage and increased chondrocyte surface area in the superficial and intermediate zone of the femoral cartilage. There was also expression of type X collagen in the femoral and tibial calcified and non-calcified cartilage; however, type X collagen was not detected in the superficial zone of old working dogs. Therefore, ageing, with or without physical activity, leads to slight cartilage degeneration, while physical activity modulates the synthesis of type X collagen in the superficial cartilage zone, partially preserving the structure of hyaline cartilage. 2014 Elsevier Ltd. All rights reserved.

  15. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  16. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  17. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  18. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  19. 32 CFR Attachment 4 to Part 855 - Sample Joint-Use Agreement

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... facilities for training. f. Air Force-owned airfield pavements made available for use under this Agreement... jointly used by Air Force aircraft will be designed to support the type of military aircraft assigned to... Transportation Safety Board, remove crashed civil aircraft from Air Force-owned pavements or property and shall...

  20. Correlation between osteoarthritic changes in the stifle joint in dogs and the results of orthopedic, radiographic, ultrasonographic and arthroscopic examinations.

    PubMed

    Ramírez-Flores, Gabriel Ignacio; Del Angel-Caraza, Javier; Quijano-Hernández, Israel Alejandro; Hulse, Don A; Beale, Brian S; Victoria-Mora, José Mauro

    2017-06-01

    Osteoarthritis (OA) is a chronic, degenerative disease affecting the articular cartilage and subchondral bone that causes pain and inhibits movement. The stifle's joint fibrous capsule contains the synovial membrane, which produces cartilage nutrients. A ruptured cranial cruciate ligament injures the joint and produces OA. Osteoarthritis diagnosis starts with clinical radiographic and ultrasonographic tests, although the latter is not used very much in dog and cat clinics for this purpose. The objective of this study was to establish the correlation among the results of orthopedic, radiographic, ultrasonographic examinations and structural anatomical changes revealed by arthroscopic evaluation to diagnose stifle joint OA and determine risk factors in the dogs affected. Of 44 clinical cases of OA included in the study, 88.64% had ruptured of cranial cruciate ligaments. The correlation between synovial fluid effusion and osteophytosis was of 0.84. It was concluded that there is good diagnostic agreement between synovial fluid effusion and osteophytosis when dealing with stifle joint OA. Risk factors for dogs regarding the development of stifle joint OA included: ruptured cranial cruciate ligaments or patella luxation, female dogs and weight over 10 kg.

  1. Optimum design of Geodesic dome’s jointing system

    NASA Astrophysics Data System (ADS)

    Tran, Huy. T.

    2018-04-01

    This study attempts to create a new design for joint connector of Geodesic dome. A new type of joint connector design is proposed for flexible rotating connection; comparing it to another, this design is cheaper and workable. After calculating the bearing capacity of the sample according to EC3 and Vietnam standard TCVN 5575-2012, FEM model of the design sample is carried out in many specific situation to consider the stress distribution, the deformation, the local destruction… in the connector. The analytical results and the FE data are consistent. The FE analysis also points out the behavior of some details that simple calculation cannot show. Hence, we can choose the optimum design of joint connector.

  2. Prescription and illicit psychoactive drugs in oral fluid--LC-MS/MS method development and analysis of samples from Brazilian drivers.

    PubMed

    Zancanaro, Ivomar; Limberger, Renata Pereira; Bohel, Paula O; dos Santos, Maíra Kerpel; De Boni, Raquel B; Pechansky, Flavio; Caldas, Eloisa Dutra

    2012-11-30

    This study is part of a larger project designed to investigate the prevalence of psychoactive drug (PAD) use among Brazilian drivers. In this paper we describe the development and validation of an analytical method to analyze 32 prescription and illicit PADs (amphetamines, benzodiazepines, cocaine, cannabis, opioids, ketamine and m-CPP) and metabolites in oral fluid samples collected with a Quantisal™ device. Samples were extracted with ethyl acetate:hexane and analyzed by LC-MS/MS. Instrumental LOD ranged from 0.26 to 0.65 ng/mL. Mean procedural recoveries at 1.3 ng/mL (LLOQ) ranged from 50% to 120% for 24 compounds. Recoveries were concentration independent, with the exception of femproporex, heroin and ecgonine methyl-ester (EME) for which the recovery decreased significantly at higher levels (13 and 52 ng/mL). RSD was <20% for all compounds at all spiking levels. Ion suppression due to the matrix was <20% for most compounds, and higher than 60% for EME and diethylpropion. Analysis was performed against a in-matrix standard curve. About 10% of the 2235 oral fluid samples collected from drivers on Brazilian Federal highways were positive (≥LOD) for at least one analyte investigated. Alone or in combination with other drugs, cocaine/metabolites were the analytes most detected in the samples (129; 5.8%), followed by amphetamines/metabolite (69; 3.1%), benzodiazepines (28; 1.2%), cannabinoids (23; 1.1%) and opioids (8; 0.4%). Detection of at least two PADs from different classes accounted for 9.3% of the 236 positive samples. Cocaine was found at higher levels in the samples (up to 1165 ng/mL). Preventive measures aimed at reducing the use of PADs by drivers in Brazil will certainly contribute to decrease the country's highway death rates. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Use of self-actuating and self-sensing cantilevers for imaging biological samples in fluid

    PubMed Central

    Barbero, R J; Deutschinger, A; Todorov, V; Gray, D S; Belcher, A M; Rangelow, I W; Youcef-Toumi, K

    2014-01-01

    In this paper, we present a detailed investigation into the suitability of atomic force microscopy (AFM) cantilevers with integrated deflection sensor and micro-actuator for imaging of soft biological samples in fluid. The Si cantilevers are actuated using a micro-heater at the bottom end of the cantilever. Sensing is achieved through p-doped resistors connected in a Wheatstone bridge. We investigated the influence of the water on the cantilever dynamics, the actuation and the sensing mechanisms, as well as the crosstalk between sensing and actuation. Successful imaging of yeast cells in water using the integrated sensor and actuator shows the potential of the combination of this actuation and sensing method. This constitutes a major step towards the automation and miniaturization required to establish AFM in routine biomedical diagnostics and in vivo applications. PMID:19801750

  4. Elevated synovial fluid concentration of adenosine triphosphate in dogs with osteoarthritis or sodium urate-induced synovitis of the stifle.

    PubMed

    Torres, Bryan T; Jimenez, David A; Budsberg, Steven C

    2016-07-19

    Adenosine triphosphate has been shown to stimulate nociceptive nerve terminals in joints. Elevated synovial fluid adenosine triphosphate concentrations as well as a correlation between synovial fluid adenosine triphosphate concentrations and osteoarthritic knee pain has been demonstrated in humans, but not yet in dogs. This study documented elevated synovial fluid adenosine triphosphate concentrations in the stifles of dogs with secondary osteoarthritis and urate-induced synovitis, as compared to normal stifles.

  5. Raman spectroscopic signature of vaginal fluid and its potential application in forensic body fluid identification.

    PubMed

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K

    2012-03-10

    Traces of human body fluids, such as blood, saliva, sweat, semen and vaginal fluid, play an increasingly important role in forensic investigations. However, a nondestructive, easy and rapid identification of body fluid traces at the scene of a crime has not yet been developed. The obstacles have recently been addressed in our studies, which demonstrated the considerable potential of Raman spectroscopy. In this study, we continued to build a full library of body fluid spectroscopic signatures. The problems concerning vaginal fluid stain identification were addressed using Raman spectroscopy coupled with advanced statistical analysis. Calculated characteristic Raman and fluorescent spectral components were used to build a multidimensional spectroscopic signature of vaginal fluid, which demonstrated good specificity and was able to handle heterogeneous samples from different donors. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Bacterial infective arthritis of the coxofemoral joint in dogs with hip dysplasia.

    PubMed

    Benzioni, H; Shahar, R; Yudelevitch, S; Milgram, J

    2008-01-01

    The objective of this study was to describe seven cases of unilateral bacterial infective coxarthritis from a total of 19 cases of bacterial infective arthritis (BIA), presenting over a two year period. We recorded the history, clinical signs, diagnostic process, treatment and clinical outcome in these cases. The data were obtained from medical records, review of the radiographs, and telephone follow-up with the owners. All of the dogs in this study had severe chronic osteoarthritis secondary to hip dysplasia, which caused periodic hind limb lameness. They were all admitted with severe acute hind-limb lameness. Pelvic radiographs were performed under general anaesthesia shortly after presentation, followed immediately by arthrocentesis of the affected joint. The synovial fluid was evaluated microscopically by direct smear and a sample was sent for culture and sensitivity. An attempt was not made to drain or lavage the affected joint during the course of treatment. The initial choice of antibiotics was empiric and subsequently modified, as required, based on the sensitivity results. Four of the dogs showed a rapid return to weight-bearing after the initiation of antibiotic treatment, and all of the patients returned to their pre-BIA level of function. Neither recurrent infections nor any adverse sequela requiring further intervention were reported by the owners on telephone follow-up.

  7. Flexible Inhibitor Fluid-Structure Interaction Simulation in RSRM.

    NASA Astrophysics Data System (ADS)

    Wasistho, Bono

    2005-11-01

    We employ our tightly coupled fluid/structure/combustion simulation code 'Rocstar-3' for solid propellant rocket motors to study 3D flows past rigid and flexible inhibitors in the Reusable Solid Rocket Motor (RSRM). We perform high resolution simulations of a section of the rocket near the center joint slot at 100 seconds after ignition, using inflow conditions based on less detailed 3D simulations of the full RSRM. Our simulations include both inviscid and turbulent flows (using LES dynamic subgrid-scale model), and explore the interaction between the inhibitor and the resulting fluid flow. The response of the solid components is computed by an implicit finite element solver. The internal mesh motion scheme in our block-structured fluid solver enables our code to handle significant changes in geometry. We compute turbulent statistics and determine the compound instabilities originated from the natural hydrodynamic instabilities and the inhibitor motion. The ultimate goal is to studdy the effect of inhibitor flexing on the turbulent field.

  8. Flutter instability of freely hanging articulated pipes conveying fluid

    NASA Astrophysics Data System (ADS)

    Schouveiler, Lionel; Chermette, Félix

    2018-03-01

    We experimentally investigate the stability of freely hanging articulated pipes made of rigid segments connected by flexible joints and with their displacements constrained in a vertical plane. When the velocity of the fluid conveyed by the pipe is increased, flutter-type instability occurs above a critical value. The critical velocity and the characteristics of the flutter modes (frequency, amplitude, and shape) are determined as a function of the number n of segments into the pipe which is varied from 2 to 5. Experimental results are compared to predictions from linear stability analysis extending previous studies by taking into account damping due to the dissipation in the joints. Qualitative agreement is found and the limits of the analysis are discussed.

  9. Review of Prospects of Biological Fluid Biomarkers in Osteoarthritis

    PubMed Central

    Nguyen, Lich Thi; Sharma, Ashish Ranjan; Chakraborty, Chiranjib; Saibaba, Balaji; Ahn, Moo-Eob; Lee, Sang-Soo

    2017-01-01

    Osteoarthritis (OA) is a degenerative disease of the joints and is one of the leading causes of disability in adults. However, there are no key therapeutics for OA and medical treatment is based on managing the symptoms and slowing down progression of the disease. Diagnostics based on clinical examination and radiography have provided little information about metabolic changes in joint tissues, disease onset and progression. Due to lack of effective methods for early detection and evaluation of treatment outcome, the measurement of biochemical markers (biomarkers) shows promise as a prospective method aiding in disease monitoring. OA biomarkers that are present in biological fluids such as blood, urine and synovial fluid, sources that are easily isolated from body, are of particular interest. Moreover, there are increasingly more studies identifying and developing new biomarkers for OA. In this review, efforts have been made to summarize the biomarkers that have been reported in recent studies on patients. We also tried to classify biomarkers according to tissue metabolism (bone, cartilage and synovial metabolism markers), pathological pathways (inflammatory and genetic markers) and biological function (chemokines, growth factors, acute phase proteins, etc.). PMID:28287489

  10. Apparatus and method for time-integrated, active sampling of contaminants in fluids demonstrated by monitoring of hexavalent chromium in groundwater.

    PubMed

    Roll, Isaac B; Driver, Erin M; Halden, Rolf U

    2016-06-15

    Annual U.S. expenditures of $2B for site characterization invite the development of new technologies to improve data quality while reducing costs and minimizing uncertainty in groundwater monitoring. This work presents a new instrument for time-integrated sampling of environmental fluids using in situ solid-phase extraction (SPE). The In Situ Sampler (IS2) is an automated submersible device capable of extracting dissolved contaminants from water (100s-1000smL) over extended periods (hours to weeks), retaining the analytes, and rejecting the processed fluid. A field demonstration of the IS2 revealed 28-day average concentration of hexavalent chromium in a shallow aquifer affected by tidal stresses via sampling of groundwater as both liquid and sorbed composite samples, each obtained in triplicate. In situ SPE exhibited 75±6% recovery and an 8-fold improvement in reporting limit. Relative to use of conventional methods (100%), beneficial characteristics of the device and method included minimal hazardous material generation (2%), transportation cost (10%), and associated carbon footprint (2%). The IS2 is compatible with commercial SPE resins and standard extraction methods, and has been certified for more general use (i.e., inorganics and organics) by the Environmental Security Technology Certification Program (ESTCP) of the U.S. Department of Defense. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Oral fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure

    PubMed Central

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2018-01-01

    Background Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. Objective To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Methods Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multiplied-immunoassay-technique and in oral fluid by liquid chromatography tandem mass spectrometry (LC-MSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Results Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). Conclusion/Discussion These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. PMID:29173162

  12. Oral Fluid vs. Urine Analysis to Monitor Synthetic Cannabinoids and Classic Drugs Recent Exposure.

    PubMed

    Blandino, Vincent; Wetzel, Jillian; Kim, Jiyoung; Haxhi, Petrit; Curtis, Richard; Concheiro, Marta

    2017-01-01

    Urine is a common biological sample to monitor recent drug exposure, and oral fluid is an alternative matrix of increasing interest in clinical and forensic toxicology. Limited data are available about oral fluid vs. urine drug disposition, especially for synthetic cannabinoids. To compare urine and oral fluid as biological matrices to monitor recent drug exposure among HIV-infected homeless individuals. Seventy matched urine and oral fluid samples were collected from 13 participants. Cannabis, amphetamines, benzodiazepines, cocaine and opiates were analyzed in urine by the enzyme-multipliedimmunoassay- technique and in oral fluid by liquid chromatography tandem mass spectrometry (LCMSMS). Eleven synthetic cannabinoids were analyzed in urine and in oral fluid by LC-MSMS. Five oral fluid samples were positive for AB-FUBINACA. In urine, 4 samples tested positive for synthetic cannabinoids PB-22, 5-Fluoro-PB-22, AB-FUBINACA, and metabolites UR-144 5-pentanoic acid and UR-144 4-hydroxypentyl. In only one case, oral fluid and urine results matched, both specimens being AB-FUBINACA positive. For cannabis, 40 samples tested positive in urine and 30 in oral fluid (85.7% match). For cocaine, 37 urine and 52 oral fluid samples were positive (75.7% match). Twenty-four urine samples were positive for opiates, and 25 in oral fluid (81.4% match). For benzodiazepines, 23 samples were positive in urine and 25 in oral fluid (85.7% match). These results offer new information about drugs disposition between urine and oral fluid. Oral fluid is a good alternative matrix to urine for monitoring cannabis, cocaine, opiates and benzodiazepines recent use; however, synthetic cannabinoids showed mixed results. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. Quantitation of pilsicainide in microscale samples of human biological fluids using liquid chromatography-tandem mass spectrometry.

    PubMed

    Shimizu, Mikiko; Hashiguchi, Masayuki; Shiga, Tsuyoshi; Nakamura, Koichi; Tamura, Hiro-omi; Mochizuki, Mayumi

    2015-03-15

    This paper describes a sensitive, reliable method to determine pilsicainide (PLC) levels in microscale sample volumes of human biological fluids using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). PLC and quinidine as an internal standard were extracted with diethylether from 0.1mL of alkalinized biological fluids. The extract was injected into an analytical column (l-column 2 ODS, 75mm×2.1mm i.d.). The mobile phase for separation consisted of 5mM ammonium acetate (pH 4.5)/methanol (4:1, v/v) and was delivered at a flow rate of 0.2mL/min. The drift voltage was 100V. The sampling aperture was heated at 120°C and the shield temperature was 260°C. The ion transitions used to monitor analytes were m/z 273→m/z 110 for PLC and m/z 325→m/z 79 for quinidine. The total time for chromatographic separation was less than 8min. The validated concentration ranges of this method for PLC were 5-2000ng/mL in plasma, 5-500ng/mL in ultrafiltered plasma solution, and 25-2000ng/mL in urine. Mean recoveries of PLC in plasma, ultrafiltered plasma solution, and urine were 93.2-99.7%, 91.4-100.6%, and 93.9-104.7%, respectively. Intra- and interday coefficients of variation for PLC were less than 6.0% and 4.3% in plasma, 6.1% and 3.7% in ultrafiltered plasma solution, and 5.4% and 2.5% in urine at the above concentration ranges, respectively. The lower limit of quantification for PLC in plasma, ultrafiltered plasma solution, and urine were 5ng/mL, 5ng/mL, and 25ng/mL, respectively. This method can be applied to pharmacokinetic study and therapeutic drug monitoring in special populations such as neonates, infants, and the elderly by making effective use of residual samples used for general clinical laboratory testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Fluid control structures in microfluidic devices

    DOEpatents

    Mathies, Richard A.; Grover, William H.; Skelley, Alison; Lagally, Eric; Liu, Chung N.

    2008-11-04

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  15. Fluid control structures in microfluidic devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathies, Richard A.; Grover, William H.; Skelley, Alison

    2017-05-09

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  16. Fluid control structures in microfluidic devices

    NASA Technical Reports Server (NTRS)

    Skelley, Alison (Inventor); Mathies, Richard A. (Inventor); Lagally, Eric (Inventor); Grover, William H. (Inventor); Liu, Chung N. (Inventor)

    2008-01-01

    Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

  17. Cross-bedding Related Anisotropy and its Role in the Orientation of Joints in an Aeolian Sandstone

    NASA Astrophysics Data System (ADS)

    Deng, S.; Cilona, A.; Mapeli, C.; Panfilau, A.; Aydin, A.; Prasad, M.

    2014-12-01

    Previous research revealed that the cross-bedding related anisotropy in aeolian sandstones affects the orientation of compaction bands, also known as anticracks. We hypothesize that cross-bedding should a have similar influence on the orientation of the joints within the same rock at the same location. To test this hypothesis, we investigated the relationship between the cross-beds and the cross-bed package confined joints in the Jurassic aeolian Aztec Sandstone cropping out in the Valley of Fire State Park, Nevada. The field data demonstrates that the cross-bed package confined joints occur at high-angle to bedding and trend roughly parallel to the dip direction of the cross-beds. This shows that the cross-bed orientation and the associated anisotropy also exert a strong control on the formation and orientation of the joints. In order to characterize the anisotropy due to cross-bedding in the Aztec Sandstone, we measured the P-wave velocities parallel and perpendicular to bedding from 11 samples in the laboratory using a bench-top ultrasonic assembly. The measured P-wave anisotropy is about 13% on average. Based on these results, a numerical model based on the generalized Hooke's law for anisotropic materials is analyzed assuming the cross-bedded sandstone to be transversely isotropic. Using this model, we tested various cross-bed orientations as well as different strain boundary conditions (uniaxial, axisymmetric and triaxial). It is possible to define a boundary condition under which the modeled results roughly match with the observed relationship between cross-bed package confined joints and cross-beds. These results have important implications for fluid flow through aeolian sandstones in reservoirs and aquifers.

  18. Delineating the joint hierarchical structure of clinical and personality disorders in an outpatient psychiatric sample.

    PubMed

    Forbes, Miriam K; Kotov, Roman; Ruggero, Camilo J; Watson, David; Zimmerman, Mark; Krueger, Robert F

    2017-11-01

    A large body of research has focused on identifying the optimal number of dimensions - or spectra - to model individual differences in psychopathology. Recently, it has become increasingly clear that ostensibly competing models with varying numbers of spectra can be synthesized in empirically derived hierarchical structures. We examined the convergence between top-down (bass-ackwards or sequential principal components analysis) and bottom-up (hierarchical agglomerative cluster analysis) statistical methods for elucidating hierarchies to explicate the joint hierarchical structure of clinical and personality disorders. Analyses examined 24 clinical and personality disorders based on semi-structured clinical interviews in an outpatient psychiatric sample (n=2900). The two methods of hierarchical analysis converged on a three-tier joint hierarchy of psychopathology. At the lowest tier, there were seven spectra - disinhibition, antagonism, core thought disorder, detachment, core internalizing, somatoform, and compulsivity - that emerged in both methods. These spectra were nested under the same three higher-order superspectra in both methods: externalizing, broad thought dysfunction, and broad internalizing. In turn, these three superspectra were nested under a single general psychopathology spectrum, which represented the top tier of the hierarchical structure. The hierarchical structure mirrors and extends upon past research, with the inclusion of a novel compulsivity spectrum, and the finding that psychopathology is organized in three superordinate domains. This hierarchy can thus be used as a flexible and integrative framework to facilitate psychopathology research with varying levels of specificity (i.e., focusing on the optimal level of detailed information, rather than the optimal number of factors). Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Torque Control of a Rehabilitation Teaching Robot Using Magneto-Rheological Fluid Clutches

    NASA Astrophysics Data System (ADS)

    Hakogi, Hokuto; Ohaba, Motoyoshi; Kuramochi, Naimu; Yano, Hidenori

    A new robot that makes use of MR-fluid clutches for simulating torque is proposed to provide an appropriate device for training physical therapy students in knee-joint rehabilitation. The feeling of torque provided by the robot is expected to correspond to the torque performance obtained by physical therapy experts in a clinical setting. The torque required for knee-joint rehabilitation, which is a function of the rotational angle and the rotational angular velocity of a knee movement, is modeled using a mechanical system composed of typical spring-mass-damper elements. The robot consists of two MR-fluid clutches, two induction motors, and a feedback control system. In the torque experiments, output torque is controlled using the spring and damper coefficients separately. The values of these coefficients are determined experimentally. The experimental results show that the robot would be suitable for training physical therapy students to experience similar torque feelings as needed in a clinical situation.

  20. Season of Sampling and Season of Birth Influence Serotonin Metabolite Levels in Human Cerebrospinal Fluid

    PubMed Central

    Luykx, Jurjen J.; Bakker, Steven C.; Lentjes, Eef; Boks, Marco P. M.; van Geloven, Nan; Eijkemans, Marinus J. C.; Janson, Esther; Strengman, Eric; de Lepper, Anne M.; Westenberg, Herman; Klopper, Kai E.; Hoorn, Hendrik J.; Gelissen, Harry P. M. M.; Jordan, Julian; Tolenaar, Noortje M.; van Dongen, Eric P. A.; Michel, Bregt; Abramovic, Lucija; Horvath, Steve; Kappen, Teus; Bruins, Peter; Keijzers, Peter; Borgdorff, Paul; Ophoff, Roel A.; Kahn, René S.

    2012-01-01

    Background Animal studies have revealed seasonal patterns in cerebrospinal fluid (CSF) monoamine (MA) turnover. In humans, no study had systematically assessed seasonal patterns in CSF MA turnover in a large set of healthy adults. Methodology/Principal Findings Standardized amounts of CSF were prospectively collected from 223 healthy individuals undergoing spinal anesthesia for minor surgical procedures. The metabolites of serotonin (5-hydroxyindoleacetic acid, 5-HIAA), dopamine (homovanillic acid, HVA) and norepinephrine (3-methoxy-4-hydroxyphenylglycol, MPHG) were measured using high performance liquid chromatography (HPLC). Concentration measurements by sampling and birth dates were modeled using a non-linear quantile cosine function and locally weighted scatterplot smoothing (LOESS, span = 0.75). The cosine model showed a unimodal season of sampling 5-HIAA zenith in April and a nadir in October (p-value of the amplitude of the cosine = 0.00050), with predicted maximum (PCmax) and minimum (PCmin) concentrations of 173 and 108 nmol/L, respectively, implying a 60% increase from trough to peak. Season of birth showed a unimodal 5-HIAA zenith in May and a nadir in November (p = 0.00339; PCmax = 172 and PCmin = 126). The non-parametric LOESS showed a similar pattern to the cosine in both season of sampling and season of birth models, validating the cosine model. A final model including both sampling and birth months demonstrated that both sampling and birth seasons were independent predictors of 5-HIAA concentrations. Conclusion In subjects without mental illness, 5-HT turnover shows circannual variation by season of sampling as well as season of birth, with peaks in spring and troughs in fall. PMID:22312427

  1. Fluid-deposited graphitic inclusions in quartz: Comparison between KTB (German Continental Deep-Drilling) core samples and artificially reequilibrated natural inclusions

    USGS Publications Warehouse

    Pasteris, J.D.; Chou, I.-Ming

    1998-01-01

    We used Raman microsampling spectroscopy (RMS) to determine the degree of crystallinity of minute (2-15 ??m) graphite inclusions in quartz in two sets of samples: experimentally reequilibrated fluid inclusions in a natural quartz grain and biotite-bearing paragneisses from the KTB deep drillhole in SE Germany. Our sequential reequilibration experiments at 725??C on initially pure CO2 inclusions in a quartz wafer and the J. Krautheim (1993) experiments at 900-1100??C on organic compounds heated in gold or platinum capsules suggest that, at a given temperature, (1) fluid-deposited graphite will have a lower crystallinity than metamorphosed organic matter and (2) that the crystallinity of fluid-deposited graphite is affected by the composition of the fluid from which it was deposited. We determined that the precipitation of more-crystalline graphite is favored by lower fH2 (higher fO2), and that the crystallinity of graphite is established by the conditions (including gas fugacities) that pertain as the fluid first reaches graphite saturation. Graphite inclusions within quartz grains in the KTB rocks show a wide range in crystallinity index, reflecting three episodes of carbon entrapment under different metamorphic conditions. Isolated graphite inclusions have the spectral properties of totally ordered, completely crystalline graphite. Such crystallinity suggests that the graphite was incorporated from the surrounding metasedimentary rocks, which underwent metamorphism at upper amphibolite-facies conditions. Much of the fluid-deposited graphite in fluid inclusions, however, shows some spectral disorder. The properties of that graphite resemble those of experimental precipitates at temperatures in excess of 700??C and at elevated pressures, suggesting that the inclusions represent precipitates from C-O-H fluids trapped under conditions near those of peak metamorphism at the KTB site. In contrast, graphite that is intimately associated with chlorite and other

  2. Recrystallization Behavior in Mixed Solder Joints of BGA Components during Thermal Shock

    NASA Astrophysics Data System (ADS)

    Tan, Shihai; Han, Jing; Guo, Fu

    2018-03-01

    Sn-37Pb and Sn-3.0Ag-0.5Cu solder pastes printed onto a board were attached to ball grid array (BGA) samples using Sn-3.0Ag-0.5Cu solder balls. Before thermal shock, the initial grain orientations on the cross-section were obtained by scanning electron microscopy equipped with an electron backscattered diffraction system. Three mixed solder joints (two from the corner and another from the middle of the BGA component) and three lead-free solder joints (at the same positions) were selected to investigate the recrystallization behavior under thermal shock (TS) cycling conditions. All of the mixed and lead-free solder joints were initially single crystal. The results showed that recrystallization occurred in both the mixed and lead-free solder joints after 200 TS. For the mixed solder joints, more recrystallization was observed and the location of samples had a significant influence on their recrystallization behavior, while location was not as important for the lead-free samples after 200 TS in this study. Both the mixed and lead-free solder joints at the corner of BGA components showed the poorest reliability. According to misorientation distribution maps and subgrain rotation behaviors, the reliability of mixed solder joints was much poorer than that of lead-free solder joints.

  3. Inverse supercritical fluid extraction as a sample preparation method for the analysis of the nanoparticle content in sunscreen agents.

    PubMed

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; de Vries, Tjerk; Portugal-Cohen, Meital; Antonio, Diana C; Cascio, Claudia; Calzolai, Luigi; Gilliland, Douglas; de Mello, Andrew

    2016-04-01

    We demonstrate the use of inverse supercritical carbon dioxide (scCO2) extraction as a novel method of sample preparation for the analysis of complex nanoparticle-containing samples, in our case a model sunscreen agent with titanium dioxide nanoparticles. The sample was prepared for analysis in a simplified process using a lab scale supercritical fluid extraction system. The residual material was easily dispersed in an aqueous solution and analyzed by Asymmetrical Flow Field-Flow Fractionation (AF4) hyphenated with UV- and Multi-Angle Light Scattering detection. The obtained results allowed an unambiguous determination of the presence of nanoparticles within the sample, with almost no background from the matrix itself, and showed that the size distribution of the nanoparticles is essentially maintained. These results are especially relevant in view of recently introduced regulatory requirements concerning the labeling of nanoparticle-containing products. The novel sample preparation method is potentially applicable to commercial sunscreens or other emulsion-based cosmetic products and has important ecological advantages over currently used sample preparation techniques involving organic solvents. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Fish oil decreases matrix metalloproteinases in knee synovia of dogs with inflammatory joint disease.

    PubMed

    Hansen, Rodney A; Harris, Mary A; Pluhar, G Elizabeth; Motta, Tatiana; Brevard, Sean; Ogilvie, Gregory K; Fettman, Martin J; Allen, Kenneth G D

    2008-02-01

    This study was designed to determine whether dietary fish oil affects the expression and activity of matrix metalloproteinases (MMP), tissue inhibitors of MMP-2 (TIMP-2) and urokinase plasminogen activator (uPA) in synovial fluid from dogs with spontaneously occurring stifle (knee) instability in a single hind limb resulting from acute cranial cruciate ligament (CCL) injury. Two groups of 12 dogs were fed diets from 1 week prior to surgery on the affected knee to 56 days post-surgery. The fish oil and control diets provided 90 and 4.5 mg, respectively, of combined eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA)/kg body weight per day. Plasma and synovial fluid, from both surgical and nonsurgical knee joints, were obtained at start of the diet (-7), surgery day (0) and 7, 14, 28 and 56 days post-surgery. Plasma total EPA and DHA were significantly increased, and plasma total arachidonic acid (AA) was significantly decreased by the fish oil diet. In synovial fluid from the nonsurgical knee, fish oil treatment significantly decreased proMMP-2 expression at Days 7 and 14, and proMMP-9 expression at Day 56, and uPA activity at 28 days and significantly increased TIMP-2 expression at Days 7 and 28. There were no differences in MMP expression or activity, TIMP-2 expression and uPA activity in the surgical joint synovial fluid at any time throughout the study. These results suggest that dietary fish oil may exert beneficial effects on synovial fluid MMP and TIMP-2 equilibrium in the uninjured stifle of dogs with unilateral CCL injury.

  5. An in vitro simulation method for the tribological assessment of complete natural hip joints

    PubMed Central

    Fisher, John; Williams, Sophie

    2017-01-01

    The use of hip joint simulators to evaluate the tribological performance of total hip replacements is widely reported in the literature, however, in vitro simulation studies investigating the tribology of the natural hip joint are limited with heterogeneous methodologies reported. An in vitro simulation system for the complete natural hip joint, enabling the acetabulum and femoral head to be positioned with different orientations whilst maintaining the correct joint centre of rotation, was successfully developed for this study. The efficacy of the simulation system was assessed by testing complete, matched natural porcine hip joints and porcine hip hemiarthroplasty joints in a pendulum friction simulator. The results showed evidence of biphasic lubrication, with a non-linear increase in friction being observed in both groups. Lower overall mean friction factor values in the complete natural joint group that increased at a lower rate over time, suggest that the exudation of fluid and transition to solid phase lubrication occurred more slowly in the complete natural hip joint compared to the hip hemiarthroplasty joint. It is envisaged that this methodology will be used to investigate morphological risk factors for developing hip osteoarthritis, as well as the effectiveness of early interventional treatments for degenerative hip disease. PMID:28886084

  6. Microscope-Based Fluid Physics Experiments in the Fluids and Combustion Facility on ISS

    NASA Technical Reports Server (NTRS)

    Doherty, Michael P.; Motil, Susan M.; Snead, John H.; Malarik, Diane C.

    2000-01-01

    At the NASA Glenn Research Center, the Microgravity Science Program is planning to conduct a large number of experiments on the International Space Station in both the Fluid Physics and Combustion Science disciplines, and is developing flight experiment hardware for use within the International Space Station's Fluids and Combustion Facility. Four fluids physics experiments that require an optical microscope will be sequentially conducted within a subrack payload to the Fluids Integrated Rack of the Fluids and Combustion Facility called the Light Microscopy Module, which will provide the containment, changeout, and diagnostic capabilities to perform the experiments. The Light Microscopy Module is planned as a fully remotely controllable on-orbit microscope facility, allowing flexible scheduling and control of experiments within International Space Station resources. This paper will focus on the four microscope-based experiments, specifically, their objectives and the sample cell and instrument hardware to accommodate their requirements.

  7. Fabrication of a micro-fluid gathering tool for the gastrointestinal juice sampling function of a versatile capsular endoscope.

    PubMed

    Koo, Kyo-In; Lee, Sangmin; Cho, Dong-il Dan

    2011-01-01

    This paper presents a micro-fluid gathering tool for a versatile capsular endoscope that employs a solid chemical propellant, azobisisobutyronitrile (AIBN). The proposed tool consists of a micro-heater, an AIBN matrix, a Venturi tube, a reservoir, an inlet, and an outlet. The micro-heater heats the AIBN matrix to be decomposed into by-products and nitrogen gas. This nitrogen gas generates negative pressure passing through the Venturi tube. The generated negative pressure inhales a target fluid from around the inlet into the reservoir. All the parts are designed to be embedded inside a cylindrical shape with a diameter of 17 mm and a height of 2.3 mm in order to integrate it into a versatile developmental capsular endoscope without any scaledown. Two sets of the proposed tools are fabricated and tested: one is made of polydimethylsiloxane (PDMS) and the other is made of polymethylmethacrylate (PMMA). In performance comparisons, the PDMS gathering tool can withstand a stronger pulling force, and the PMMA gathering tool requires a less negative pressure for inhaling the same target fluid. Due to the instant and full activation of the thin AIBN matrix, both types of gathering tool show analogous performance in the sample gathering evaluation. The gathered volume is approximately 1.57 μL using approximately 25.4 μL of AIBN compound.

  8. Fabrication of a Micro-Fluid Gathering Tool for the Gastrointestinal Juice Sampling Function of a Versatile Capsular Endoscope

    PubMed Central

    Koo, Kyo-in; Lee, Sangmin; Cho, Dong-il Dan

    2011-01-01

    This paper presents a micro-fluid gathering tool for a versatile capsular endoscope that employs a solid chemical propellant, azobisisobutyronitrile (AIBN). The proposed tool consists of a micro-heater, an AIBN matrix, a Venturi tube, a reservoir, an inlet, and an outlet. The micro-heater heats the AIBN matrix to be decomposed into by-products and nitrogen gas. This nitrogen gas generates negative pressure passing through the Venturi tube. The generated negative pressure inhales a target fluid from around the inlet into the reservoir. All the parts are designed to be embedded inside a cylindrical shape with a diameter of 17 mm and a height of 2.3 mm in order to integrate it into a versatile developmental capsular endoscope without any scaledown. Two sets of the proposed tools are fabricated and tested: one is made of polydimethylsiloxane (PDMS) and the other is made of polymethylmethacrylate (PMMA). In performance comparisons, the PDMS gathering tool can withstand a stronger pulling force, and the PMMA gathering tool requires a less negative pressure for inhaling the same target fluid. Due to the instant and full activation of the thin AIBN matrix, both types of gathering tool show analogous performance in the sample gathering evaluation. The gathered volume is approximately 1.57 μL using approximately 25.4 μL of AIBN compound. PMID:22163997

  9. Consistency argued students of fluid

    NASA Astrophysics Data System (ADS)

    Viyanti; Cari; Suparmi; Winarti; Slamet Budiarti, Indah; Handika, Jeffry; Widyastuti, Fatma

    2017-01-01

    Problem solving for physics concepts through consistency arguments can improve thinking skills of students and it is an important thing in science. The study aims to assess the consistency of the material Fluid student argmentation. The population of this study are College students PGRI Madiun, UIN Sunan Kalijaga Yogyakarta and Lampung University. Samples using cluster random sampling, 145 samples obtained by the number of students. The study used a descriptive survey method. Data obtained through multiple-choice test and interview reasoned. Problem fluid modified from [9] and [1]. The results of the study gained an average consistency argmentation for the right consistency, consistency is wrong, and inconsistent respectively 4.85%; 29.93%; and 65.23%. Data from the study have an impact on the lack of understanding of the fluid material which is ideally in full consistency argued affect the expansion of understanding of the concept. The results of the study as a reference in making improvements in future studies is to obtain a positive change in the consistency of argumentations.

  10. Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.

    PubMed

    Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil

    2016-11-01

    Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Nanopipettes: probes for local sample analysis.

    PubMed

    Saha-Shah, Anumita; Weber, Anna E; Karty, Jonathan A; Ray, Steven J; Hieftje, Gary M; Baker, Lane A

    2015-06-01

    Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

  12. Hot wire anemometer measurements in the unheated air flow tests of the SRB nozzle-to-case joint

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.

    1988-01-01

    Hot-Wire Anemometer measurements made in the Solid Rocket Booster (SRB) nozzle-to-case joint are discussed. The study was undertaken to glean additional information on the circumferential flow induced in the SRB nozzle joint and the effect of this flow on the insulation bonding flaws. The tests were conducted on a full-scale, 2-D representation of a 65-in long segment of the SRB nozzle joint, with unheated air as the working fluid. Both the flight Mach number and Reynolds number were matched simultaneously and different pressure gradients imposed along the joint face were investigated. Hot-wire anemometers were used to obtain velocity data for different joint gaps and debond configurations. The procedure adopted for hot-wire calibration and use is outlined and the results from the tests summarized.

  13. Detecting low levels of radionuclides in fluids

    DOEpatents

    Patch, Keith D.; Morgan, Dean T.

    2000-01-01

    An apparatus and method for detecting low levels of one or more radionuclides in a fluid sample uses a substrate that includes an ion exchange resin or other sorbent material to collect the radionuclides. A collecting apparatus includes a collecting chamber that exposes the substrate to a measured amount of the fluid sample such that radionuclides in the fluid sample are collected by the ion exchange resin. A drying apparatus, which can include a drying chamber, then dries the substrate. A measuring apparatus measures emissions from radionuclides collected on the substrate. The substrate is positioned in a measuring chamber proximate to a detector, which provides a signal in response to emissions from the radionuclides. Other analysis methods can be used to detect non-radioactive analytes, which can be collected with other types of sorbent materials.

  14. Seabed roughness parameters from joint backscatter and reflection inversion at the Malta Plateau.

    PubMed

    Steininger, Gavin; Holland, Charles W; Dosso, Stan E; Dettmer, Jan

    2013-09-01

    This paper presents estimates of seabed roughness and geoacoustic parameters and uncertainties on the Malta Plateau, Mediterranean Sea, by joint Bayesian inversion of mono-static backscatter and spherical wave reflection-coefficient data. The data are modeled using homogeneous fluid sediment layers overlying an elastic basement. The scattering model assumes a randomly rough water-sediment interface with a von Karman roughness power spectrum. Scattering and reflection data are inverted simultaneously using a population of interacting Markov chains to sample roughness and geoacoustic parameters as well as residual error parameters. Trans-dimensional sampling is applied to treat the number of sediment layers and the order (zeroth or first) of an autoregressive error model (to represent potential residual correlation) as unknowns. Results are considered in terms of marginal posterior probability profiles and distributions, which quantify the effective data information content to resolve scattering/geoacoustic structure. Results indicate well-defined scattering (roughness) parameters in good agreement with existing measurements, and a multi-layer sediment profile over a high-speed (elastic) basement, consistent with independent knowledge of sand layers over limestone.

  15. Sample processor for chemical analysis

    NASA Technical Reports Server (NTRS)

    Boettger, Heinz G. (Inventor)

    1980-01-01

    An apparatus is provided which can process numerous samples that must be chemically analyzed by the application of fluids such as liquid reagents, solvents and purge gases, as well as the application of dumps for receiving the applied fluid after they pass across the sample, in a manner that permits numerous samples to be processed in a relatively short time and with minimal manpower. The processor includes a rotor which can hold numerous cartridges containing inert or adsorbent material for holding samples, and a pair of stators on opposite sides of the rotor. The stators form stations spaced along the path of the cartridges which lie in the rotor, and each station can include an aperture in one stator through which a fluid can be applied to a cartridge resting at that station, and an aperture in the other stator which can receive the fluid which has passed through the cartridge. The stators are sealed to the ends of the cartridges lying on the rotor, to thereby isolate the stations from one another.

  16. Synovial fluid proteomics in the pursuit of arthritis mediators: An evolving field of novel biomarker discovery.

    PubMed

    Mahendran, Shalini M; Oikonomopoulou, Katerina; Diamandis, Eleftherios P; Chandran, Vinod

    Synovial fluid (SF) is a protein-rich fluid produced into the joint cavity by cells of the synovial membrane. Due to its direct contact with articular cartilage, surfaces of the bone, and the synoviocytes of the inner membrane, it provides a promising reflection of the biochemical state of the joint under varying physiological and pathophysiological conditions. This property of SF has been exploited within numerous studies in search of unique biomarkers of joint pathologies with the ultimate goal of developing minimally invasive clinical assays to detect and/or monitor disease states. Several proteomic methodologies have been employed to mine the SF proteome. From elementary immunoassays to high-throughput analyses using mass spectrometry-based techniques, each has demonstrated distinct advantages and disadvantages in the identification and quantification of SF proteins. This review will explore the role of SF in the elucidation of the arthritis proteome and the extent to which high-throughput techniques have facilitated the discovery and validation of protein biomarkers from osteoarthritis (OA), rheumatoid arthritis (RA), psoriatic arthritis (PsA), and juvenile idiopathic arthritis (JIA) patients.

  17. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    PubMed

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  18. Perilymph Sampling from the Cochlear Apex: A Reliable Method to Obtain Higher Purity Perilymph Samples from Scala Tympani

    PubMed Central

    Salt, Alec N.; Hale, Shane A.; Plontke, Stefan K. R.

    2006-01-01

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2 μL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  19. Growth and Morphology of Supercritical Fluids, a Fluid Physics Experiment Conducted on Mir, Complete

    NASA Technical Reports Server (NTRS)

    Wilkinson, R. Allen

    2001-01-01

    The Growth and Morphology of Supercritical Fluids (GMSF) is an international experiment facilitated by the NASA Glenn Research Center and under the guidance of U.S. principal investor Professor Hegseth of the University of New Orleans and three French coinvestigators: Daniel Beysens, Yves Garrabos, and Carole Chabot. The GMSF experiments were concluded in early 1999 on the Russian space station Mir. The experiments spanned the three science themes of near-critical phase separation rates, interface dynamics in near-critical boiling, and measurement of the spectrum of density fluctuation length scales very close to the critical point. The fluids used were pure CO2 or SF6. Three of the five thermostats used could adjust the sample volume with the scheduled crew time. Such a volume adjustment enabled variable sample densities around the critical density as well as pressure steps (as distinct from the usual temperature steps) applied to the sample. The French-built ALICE II facility was used for these experiments. It allows tightly thermostated (left photograph) samples (right photograph) to be controlled and viewed/measured. Its diagnostics include interferometry, shadowgraph, high-speed pressure measurements, and microscopy. Data were logged on DAT tapes, and PCMCIA cards and were returned to Earth only after the mission was over. The ground-breaking near critical boiling experiment has yielded the most results with a paper published in Physical Review Letters (ref. 1). The boiling work also received press in Science Magazine (ref. 2). This work showed that, in very compressible near-critical two-phase pure fluids, a vapor bubble was induced to temporarily overheat during a rapid heating of the sample wall. The temperature rise in the vapor was 23-percent higher than the rise in the driving container wall. The effect is due to adiabatic compression of the vapor bubble by the rapid expansion of fluid near the boundary during heatup. Thermal diffusivity is low near the

  20. Heparin-like activity in uterine fluid.

    PubMed Central

    Foley, M E; Griffin, B D; Zuzel, M; Aparicio, S R; Bradbury, K; Bird, C C; Clayton, J K; Jenkins, D M; Scott, J S; Rajah, S M; McNichol, G P

    1978-01-01

    Uterine fluid was collected from a group of normal patients and a group of patients with menorrhagia. Heparin-like activity was detected in 34 out of 38 samples using an anti-Xa heparin assay. The heparin-like activity in uterine fluid was inhibited by adding the heparin antagonist hexadimethrine bromide to the assay. Concentrations of fibrinogen-fibrin degradation products (FDPs) were measured in five samples of uterine fluid. FDPs in the concentration detected had no effect on the anti-Xa assay. Heparin-like activity was higher in the group with menorrhagia, although the differences were not significant. Heparin-like activity increased throughout the menstrual cycle and decreased during menstruation, suggesting a possible cyclical variation in activity. There was no correlation between mast cell numbers in the endometrium and myometrium and heparin-like activity in uterine fluid and no correlation between the numbers and the stage in the menstrual cycle. In a few patients with intrauterine contraceptive devices (IUCDs) heparin-like activity was increased. PMID:687899

  1. Active tactile sampling by an insect in a step-climbing paradigm

    PubMed Central

    Krause, André F.; Dürr, Volker

    2012-01-01

    Many insects actively explore their near-range environment with their antennae. Stick insects (Carausius morosus) rhythmically move their antennae during walking and respond to antennal touch by repetitive tactile sampling of the object. Despite its relevance for spatial orientation, neither the spatial sampling patterns nor the kinematics of antennation behavior in insects are understood. Here we investigate unrestrained bilateral sampling movements during climbing of steps. The main objectives are: (1) How does the antennal contact pattern relate to particular object features? (2) How are the antennal joints coordinated during bilateral tactile sampling? We conducted motion capture experiments on freely climbing insects, using steps of different height. Tactile sampling was analyzed at the level of antennal joint angles. Moreover, we analyzed contact patterns on the surfaces of both the obstacle and the antenna itself. Before the first contact, both antennae move in a broad, mostly elliptical exploratory pattern. After touching the obstacle, the pattern switches to a narrower and faster movement, caused by higher cycle frequencies and lower cycle amplitudes in all joints. Contact events were divided into wall- and edge-contacts. Wall contacts occurred mostly with the distal third of the flagellum, which is flexible, whereas edge contacts often occurred proximally, where the flagellum is stiff. The movement of both antennae was found to be coordinated, exhibiting bilateral coupling of functionally analogous joints [e.g., left head-scape (HS) joint with right scape-pedicel (SP) joint] throughout tactile sampling. In comparison, bilateral coupling between homologous joints (e.g., both HS joints) was significantly weaker. Moreover, inter-joint coupling was significantly weaker during the contact episode than before. In summary, stick insects show contact-induced changes in frequency, amplitude and inter-joint coordination during tactile sampling of climbed obstacles

  2. [The development of a finger joint phantom for the optical simulation of early inflammatory rheumatic changes].

    PubMed

    Prapavat, V; Runge, W; Mans, J; Krause, A; Beuthan, J; Müller, G

    1997-11-01

    In the field of rheumatology, conventional diagnostic methods permit the detection only of advanced stages of the disease, which is at odds with the current clinical demand for the early diagnosis of inflammatory rheumatic diseases. Prompted by current needs, we developed a finger joint phantom that enables the optical and geometrical simulation of an early stage of rheumatoid arthritis (RA). The results presented here form the experimental basis for an evaluation of new RA diagnostic systems based on near infrared light. The early stage of RA is characterised mainly by a vigorous proliferation of the synovial membrane and clouding of the synovial fluid. Using a double-integrating-sphere technique, the absorption and scattering coefficients (mua, mus') are experimentally determined for healthy and pathologically altered synovial fluid and capsule tissue. Using a variable mixture of Intralipid Indian ink and water as a scattering/absorption medium, the optical properties of skin, synovial fluid or capsule can be selected individually. Since the optical and geometrical properties of bone tissue remain constant in early-stage RA, a solid material is used for its simulation. Using the finger joint phantom described herein, the optical properties of joint regions can be adjusted specifically, enabling an evaluation of their effects on an optical signal--for example, during fluorography--and the investigation of these effects for diagnostically useful information. The experimental foundation for the development of a new optical system for the early diagnosis of RA has now been laid.

  3. Improving stability and curving passing performance for railway vehicles with a variable stiffness MRF rubber joint

    NASA Astrophysics Data System (ADS)

    Harris, B. J.; Sun, S. S.; Li, W. H.

    2017-03-01

    With the growing need for effective intercity transport, the need for more advanced rail vehicle technology has never been greater. The conflicting primary longitudinal suspension requirements of high speed stability and curving performance limit the development of rail vehicle technology. This paper presents a novel magnetorheological fluid based joint with variable stiffness characteristics for the purpose of overcoming this parameter conflict. Firstly, the joint design and working principle is developed. Following this, a prototype is tested by MTS to characterize its variable stiffness properties under a range of conditions. Lastly, the performance of the proposed MRF rubber joint with regard to improving train stability and curving performance is numerically evaluated.

  4. Hydraulic Fracturing Fluid Analysis for Regulatory Parameters - A Progress Report

    EPA Pesticide Factsheets

    This presentation is a progress report on the analysis of Hydraulic Fracturing Fluids for regulatory compounds outlined in the various US EPA methodologies. Fracturing fluids vary significantly in consistency and viscosity prior to fracturing. Due to the nature of the fluids the analytical challenges will have to be addressed. This presentation also outlines the sampling issues associated with the collection of dissolved gas samples.

  5. Temporomandibular Joint and Muscle Disorder (TMJMD) - type pain and Co-morbid Pains in a National US Sample

    PubMed Central

    Plesh, O; Adams, SH; Gansky, SA

    2013-01-01

    Aims To compare prevalences of self-reported comorbid headaches, neck, back, and joint pains in respondents with temporomandibular joint and muscle disorder (TMJMD)-type pain in the 2000–2005 US National Health Interview Survey (NHIS), and to analyze these self-reported pains by gender and age for Non-Hispanic (NH) Whites (Caucasians), Hispanics and NH Blacks (African Americans). Methods Data from the 2000–2005 NHIS included information on gender, age, race, ethnicity, education, different common types of pain (specifically: TMJMD-type, severe headache/migraine, neck, and low back pains), changes in health status; and health care utilization. Estimates and test statistics (i.e. Pearson correlations, regressions and logistic models) were conducted using SAS survey analysis and SUDAAN software that take into account the complex sample design. Results A total of 189,977 people: 52% female and 48% males; 73% NH Whites, 12% Hispanic, 11% NH Blacks and 4% “Other” were included. A total of 4.6% reported TMJMD-type pain and only 0.77% overall reported it without any comorbid headache/migraine, neck, or low back pains; also 59% of the TMJMD-type pain (N = 8,964) reported ≥two comorbid pain. Females reported more comorbid pain than males (odds ratio (OR) = 1.41, p <0.001), Hispanic and NH Blacks reported more than NH Whites (OR = 1.56, p <0.001; OR = 1.38, p <0.001, respectively). In addition, 53% of those with TMJMD-type pain had severe headache/migraines; 54% had neck pain, 64% low back pain and 62% joint pain. Differences in gender, race by age patterns were detected. For females, headache/migraine pain with TMJMD-type pain peaked around age 40 and decreased thereafter regardless of race/ethnicity. Neck pain continued to increase up to about age 60, with higher prevalence for Hispanic women at younger ages, and more pronounced in males, being the highest in the non-Whites. Low back pain was higher in Black and Hispanic females across the age span and higher

  6. Intra-slab COH fluid fluxes evidenced by fluid-mediated decarbonation of lawsonite eclogite-facies altered oceanic metabasalts

    NASA Astrophysics Data System (ADS)

    Vitale Brovarone, Alberto; Chu, Xu; Martin, Laure; Ague, Jay J.; Monié, Patrick; Groppo, Chiara; Martinez, Isabelle; Chaduteau, Carine

    2018-04-01

    The interplay between the processes controlling the mobility of H2O and C-bearing species during subduction zone metamorphism exerts a critical control on plate tectonics and global volatile recycling. Here we present the first study on fresh, carbonate-bearing, lawsonite eclogite-facies metabasalts from Alpine Corsica, France, which reached the critical depths at which important devolatilization reactions occur in subducting slabs. The studied samples indicate that the evolution of oceanic crustal sequences subducted under present-day thermal regimes is dominated by localized fluid-rock interactions that are strongly controlled by the nature and extent of inherited (sub)seafloor hydrothermal processes, and by the possibility of deep fluids to be channelized along inherited or newly-formed discontinuities. Fluid channelization along inherited discontinuities controlled local rehydration and dehydration/decarbonation reactions and the stability of carbonate and silicate minerals at the blueschist-eclogite transition. Fluid-mediated decarbonation was driven by upward, up-temperature fluid flow in the inverted geothermal gradient of a subducting oceanic slab, a process that has not been documented in natural samples to date. We estimate that the observed fluid-rock reactions released 20-60 kg CO2 per m3 of rock (i.e. 0.7-2.1 wt% CO2), which is in line with the values predicted from decarbonation of metabasalts in open systems at these depths. Conversely, the estimated time-integrated fluid fluxes (20-50 t/m2) indicate that the amount of carbon transported by channelized fluid flow within the volcanic part of subducting oceanic plates is potentially much higher than previous numerical estimates, testifying to the percolation of C-bearing fluids resulting from devolatilization/dissolution processes operative in large reservoirs.

  7. Remote Visualization and Remote Collaboration On Computational Fluid Dynamics

    NASA Technical Reports Server (NTRS)

    Watson, Val; Lasinski, T. A. (Technical Monitor)

    1995-01-01

    A new technology has been developed for remote visualization that provides remote, 3D, high resolution, dynamic, interactive viewing of scientific data (such as fluid dynamics simulations or measurements). Based on this technology, some World Wide Web sites on the Internet are providing fluid dynamics data for educational or testing purposes. This technology is also being used for remote collaboration in joint university, industry, and NASA projects in computational fluid dynamics and wind tunnel testing. Previously, remote visualization of dynamic data was done using video format (transmitting pixel information) such as video conferencing or MPEG movies on the Internet. The concept for this new technology is to send the raw data (e.g., grids, vectors, and scalars) along with viewing scripts over the Internet and have the pixels generated by a visualization tool running on the viewer's local workstation. The visualization tool that is currently used is FAST (Flow Analysis Software Toolkit).

  8. Extended Detection of Amphetamine and Methamphetamine in Oral Fluid.

    PubMed

    Andås, Hilde T; Enger, Asle; Øiestad, Åse Marit L; Vindenes, Vigdis; Christophersen, Asbjørg S; Huestis, Marilyn A; Øiestad, Elisabeth L

    2016-02-01

    Amphetamine and methamphetamine are popular drugs of abuse worldwide and are important components of drug monitoring programs. Windows of detection for amphetamine and methamphetamine in oral fluid after high doses have not been investigated. Repeated high-dose ingestions are likely to cause positive samples for extended periods. Common routes of administration of amphetamine/methamphetamine in Norway are oral intake or injection. The aim of this study was to investigate windows of detection for amphetamine and methamphetamine in oral fluid from drug addicts under sustained abstinence during detoxification. Twenty-five patients admitted to a closed detoxification unit were included in this study. Oral fluid samples were collected daily in the morning and evening, and urine every morning for 10 days. A blood sample was drawn during the first 5 days after admission if the patient consented. Oral fluid results were compared with urine results to determine whether a new ingestion occurred. Oral fluid was collected with the Intercept oral fluid collection device. In-house cutoff concentrations for amphetamine and methamphetamine were 6.8 and 7.5 mcg/L, respectively, in oral fluid, and 135 and 149 mcg/L, respectively, in urine. Amphetamines were detected in 11 oral fluid, 5 urine, and 2 blood specimens from 25 patients. Patients self-reported amphetamines intake of up to 0.5-2 g daily. Windows of detection for amphetamine and methamphetamine in oral fluid were up to 8 days, longer than in urine at the applied cutoff values. These data confirm that oral fluid is a viable alternative to urine for monitoring amphetamine abuse, and that these substances might be detected in oral fluid for at least 1 week after ingestion of high doses. Such long detection times were, as far as we are aware, never reported previously for oral fluid amphetamines.

  9. Shock Re-equilibration of Fluid Inclusions

    NASA Technical Reports Server (NTRS)

    Madden, M. E. Elwood; Horz, F.; Bodnar, R. J.

    2004-01-01

    Fluid inclusions (microscopic volumes of fluid trapped within minerals as they precipitate) are extremely common in terrestrial minerals formed under a wide range of geological conditions from surface evaporite deposits to kimberlite pipes. While fluid inclusions in terrestrial rocks are nearly ubiquitous, only a few fluid inclusion-bearing meteorites have been documented. The scarcity of fluid inclusions in meteoritic materials may be a result of (a) the absence of fluids when the mineral was formed on the meteorite parent body or (b) the destruction of fluid inclusions originally contained in meteoritic materials by subsequent shock metamorphism. However, the effects of impact events on pre-existing fluid inclusions trapped in target and projectile rocks has received little study. Fluid inclusions trapped prior to the shock event may be altered (re-equilibrated) or destroyed due to the high pressures, temperatures, and strain rates associated with impact events. By examining the effects of shock deformation on fluid inclusion properties and textures we may be able to better constrain the pressure-temperature path experienced by terrestrial and meteoritic shocked materials and also gain a clearer understanding of why fluid inclusions are rarely found in meteorite samples.

  10. Regenerative Medicine and Restoration of Joint Function

    DTIC Science & Technology

    2014-12-01

    to resist fracture and excessive deformation under antici- pated mechanical loading conditions both during the early healing process and for longer...per sample type), the results sug- gest a correlation between percent fractured sinter neck area and mechanical properties with the lowest bending...joint replacement are used to treat a joint with an intra-articular fracture or destroyed by a combat injury. Generation of personalized, anatomically

  11. Fallon, Nevada FORGE Fluid Geochemistry

    DOE Data Explorer

    Blankenship, Doug; Ayling, Bridget

    2018-03-13

    Fluid geochemistry analysis for wells supporting the Fallon FORGE project. Samples were collected from geothermal wells using standard geothermal water sampling techniques, including filtration and acidification of the cation sample to pH < 2 prior to geochemical analysis. Analyses after 2005 were done in reputable commercial laboratories that follow standard protocols for aqueous chemistry analysis.

  12. Dialysis of the rectum for sampling drug concentrations in the luminal extracellular fluid of the gut: technique and precision.

    PubMed

    Egan, L J; Sandborn, W J; Mays, D C; Tremaine, W J; Lipsky, J J

    1998-07-01

    It is useful to measure the luminal concentration of drugs which act in the gut. Dialysis of the rectum has not previously been used or validated for this purpose. To determine the precision of rectal dialysis for measuring rectal drug concentrations. To establish the duration of dialysis required to approach equilibrium, the rate of methotrexate diffusion into dialysis bags was first determined in vitro. The precision of rectal dialysis for sampling the methotrexate concentration of colonic lumen extracellular fluid was determined in seven subjects who underwent two consecutive dialysis procedures. Subjects treated with subcutaneous methotrexate for refractory inflammatory bowel disease were studied. Methotrexate crossed the dialysis membrane by a first-order process, and after a 2 h in vitro dialysis, equilibration was 74 +/- 2% (mean +/- s.d.) complete. Rectal dialysis was well tolerated by all subjects. The mean +/- s.e. methotrexate concentration of 3.6 +/- 1.1 nmol/L in the first dialysate was not significantly different from 3.6 +/- 0.9 nmol/L in the second dialysate. P = 0.99 (paired two-tailed t-test). Similar precision was obtained for an endogenous molecule, potassium, secreted by the rectal mucosa. Dialysis of the rectum is a well tolerated and precise technique for sampling the colonic lumen extracellular fluid for quantitative analyses of exogenous and endogenous substances.

  13. Candida-induced prosthetic joint infection. A literature review including 72 cases and a case report.

    PubMed

    Cobo, Fernando; Rodríguez-Granger, Javier; López, Enrique M; Jiménez, Gemma; Sampedro, Antonio; Aliaga-Martínez, Luis; Navarro-Marí, José María

    2017-02-01

    The clinical and microbiological characteristics of prosthetic joint infection (PJI) caused by Candida species is described, including 72 cases in the literature and a case of Candida glabrata infection handled at the present centre. We describe one patient and using the key words 'fungal prosthetic joint infection' and 'candida prosthetic joint infection' we searched MEDLINE (National Library of Medicine, Bethesda, MD), Web of Science, CINAHL and Cochrane systematic review databases for case reports of this condition. Out of the 73 patients, 38 were female; mean age at diagnosis was 65.7 (± SD 18) yrs; 50 had risk factors for candidal infection such as systemic disease (e.g. rheumatoid arthritis, Sjogren's syndrome, systemic lupus erythematosus) and/or immunosuppressive therapy in 18 (24.6%) cases, diabetes mellitus in 14 (19.1%), immunosuppression due to malignant or chronic disease in 24 (32.8%) and long-term antibiotic use in four (5.4%) patients. Infection site was the knee in 36 patients and hip in 35; pain was present in 43 patients and swelling in 23 and the mean surgery-diagnosis interval was 32 months. The most frequent species was C. albicans, followed by C. parapsilosis. The diagnosis was obtained from joint fluid aspirate in 33 cases and intra-operative samples in 16. Susceptibility to antifungals was tested in only 21 isolates. The most frequently used antifungals were fluconazole and amphotericin B. Two-stage exchange arthroplasty was performed in 30 patients and resection arthroplasty in 31; 56 patients were cured with a combination of medical and surgical treatment; one patient died from the infection. PJI caused by Candida requires a high index of suspicion; surgery with long-term antifungal therapy is recommended.

  14. The Standard Joint Unit.

    PubMed

    Casajuana Kögel, Cristina; Balcells-Olivero, María Mercedes; López-Pelayo, Hugo; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Nutt, David John; Rehm, Jürgen; Gual, Antoni

    2017-07-01

    Reliable data on cannabis quantities is required to improve assessment of cannabis consumption for epidemiological analysis and clinical assessment, consequently a Standard Joint Unit (SJU) based on quantity of 9-Tetrahydrocannabinol (9-THC) has been established. Naturalistic study of a convenience sample recruited from February 2015-June 2016 in universities, leisure spaces, mental health services and cannabis clubs in Barcelona. Adults, reporting cannabis use in the last 60 days, without cognitive impairment or language barriers, answered a questionnaire on cannabis use and were asked to donate a joint to further determine their 9-THC and Cannabidiol (CBD) content. 492 participants donated 315 valid joints. Donators were on average 29 years old, mostly men (77%), single (75%), with at least secondary studies (73%) and in active employment (63%). Marijuana joints (N=232) contained a median of 6.56mg of 9-THC (Interquartile range-IQR=10,22) and 0.02mg of CBD (IQR=0.02); hashish joints (N=83) a median of 7.94mg of 9-THC (IQR=10,61) and 3.24mg of CBD (IQR=3.21). Participants rolled 4 joints per gram of cannabis and paid 5€ per gram (median values). Consistent 9-THC-content in joints lead to a SJU of 7mg of 9-THC, the integer number closest to the median values shared by both cannabis types. Independently if marijuana or hashish, 1 SJU = 1 joint = 0.25 g of cannabis = 7 mg of 9-THC. For CBD, only hashish SJU contained relevant levels. Similarly to the Standard Drink Unit for alcohol, the SJU is useful for clinical, epidemiological and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Cyclic movement stimulates hyaluronan secretion into the synovial cavity of rabbit joints

    PubMed Central

    Ingram, K R; Wann, A K T; Angel, C K; Coleman, P J; Levick, J R

    2008-01-01

    The novel hypothesis that the secretion of the joint lubricant hyaluronan (HA) is coupled to movement has implications for normal function and osteoarthritis, and was tested in the knee joints of anaesthetized rabbits. After washing out the endogenous synovial fluid HA (miscibility coefficient 0.4), secretion into the joint cavity was measured over 5 h in static joints and in passively cycled joints. The net static secretion rate (11.2 ± 0.7 μg h−1, mean ± s.e.m., n = 90) correlated with the variable endogenous HA mass (mean 367 ± 8 μg), with a normalized value of 3.4 ± 0.2 μg h−1 (100 μg)−1 . Cyclic joint movement approximately doubled the net HA secretion rate to 22.6 ± 1.2 μg h−1 (n = 77) and raised the normalized percentage to 5.9 ± 0.3 μg h−1 (100 μg)−1. Secretion was inhibited by 2-deoxyglucose and iodoacetate, confirming active secretion. The net accumulation rate underestimated true secretion rate due to some trans-synovial loss. HA turnover time (endogenous mass/secretion rate) was 17–30 h (static) to 8–15 h (moved) The results demonstrate for the first time that the active secretion of HA is coupled to joint usage. Movement–secretion coupling may protect joints against the damaging effects of repetitive joint use, replace HA lost during periods of immobility (overnight), and contribute to the clinical benefit of exercise therapy in moderate osteoarthritis. PMID:18202097

  16. The Probable Explanation for the Low Friction of Natural Joints.

    PubMed

    Pawlak, Zenon; Urbaniak, Wieslaw; Hagner-Derengowska, Magdalena; Hagner, Wojciech

    2015-04-01

    The surface of an articular cartilage, coated with phospholipid (PL) bilayers, plays an important role in its lubrication and movement. Intact (normal) and depleted surfaces of the joint were modelled and the pH influence on the surface interfacial energy, wettability and friction were investigated. In the experiments, the deterioration of the PL bilayer was controlled by its wettability and the applied friction. The surrounding fluid of an undamaged articular cartilage, the synovial fluid, has a pH value of approximately 7.4. Buffer solutions were formulated to represent the synovial fluid with various pH values. It was found that the surface interfacial energy was stabilised at its lowest values when the pH varied between 6.5 and 9.5. These results suggested that as the PL bilayers deteriorated, the hydration repulsion mechanism became less effective as friction increased. The decreased number of bilayers changed the wettability and lowered PL lubricant properties.

  17. Preparation and electrical properties of oil-based magnetic fluids

    NASA Astrophysics Data System (ADS)

    Sartoratto, P. P. C.; Neto, A. V. S.; Lima, E. C. D.; Rodrigues de Sá, A. L. C.; Morais, P. C.

    2005-05-01

    This paper describes an improvement in the preparation of magnetic fluids for electrical transformers. The samples are based on surface-coated maghemite nanoparticles dispersed in transformer insulating oil. Colloidal stability at 90°C was higher for oleate-grafted maghemite-based magnetic fluid, whereas decanoate and dodecanoate-grafted samples were very unstable. Electrical properties were evaluated for samples containing 0.80%-0.0040% maghemite volume fractions. Relative permittivity varied from 8.8 to 2.1 and the minimum value of the loss factor was 12% for the most diluted sample. The resistivity falls in the range of 0.7-2.5×1010Ωm, whereas the ac dielectric strength varied from 70to79kV. These physical characteristics reveal remarkable step forward in the properties of the magnetic fluid samples and may result in better operation of electrical transformers.

  18. Metastatic carcinoma presenting as hind-limb lameness: diagnosis by synovial fluid cytology.

    PubMed

    Meinkoth, J H; Rochat, M C; Cowell, R L

    1997-01-01

    A dog presented for evaluation of left hind-limb lameness and pain associated with manipulation of the tail. Synovial metastasis of a carcinoma was diagnosed by joint fluid examination. A primary bronchiolar-alveolar carcinoma with widespread (including synovial and skeletal) metastases was diagnosed on postmortem examination. Metastasis to synovial surfaces is uncommon, but when it occurs, the metastasis-induced arthritis may be the initial presenting complaint for which medical attention is sought. Although rarely reported, cytological examination of synovial fluid may be diagnostic. This paper presents an interesting clinical case and reviews the literature concerning metastatic disease of the synovium.

  19. Microbial life in cold, hydrologically active oceanic crustal fluids

    NASA Astrophysics Data System (ADS)

    Meyer, J. L.; Jaekel, U.; Girguis, P. R.; Glazer, B. T.; Huber, J. A.

    2012-12-01

    It is estimated that at least half of Earth's microbial biomass is found in the deep subsurface, yet very little is known about the diversity and functional roles of these microbial communities due to the limited accessibility of subseafloor samples. Ocean crustal fluids, which may have a profound impact on global nutrient cycles given the large volumes of water moving through the crustal aquifer, are particularly difficult to sample. Access to uncontaminated ocean crustal fluids is possible with CORK (Circulation Obviation Retrofit Kit) observatories, installed through the Integrated Ocean Drilling Program (IODP). Here we present the first microbiological characterization of the formation fluids from cold, oxygenated igneous crust at North Pond on the western flank of the Mid Atlantic Ridge. Fluids were collected from two CORKs installed at IODP boreholes 1382A and 1383C and include fluids from three different depth horizons within oceanic crust. Collection of borehole fluids was monitored in situ using an oxygen optode and solid-state voltammetric electrodes. In addition, discrete samples were analyzed on deck using a comparable lab-based system as well as a membrane-inlet mass spectrometer to quantify all dissolved volatiles up to 200 daltons. The instruments were operated in parallel and both in situ and shipboard geochemical measurements point to a highly oxidized fluid, revealing an apparent slight depletion of oxygen in subsurface fluids (~215μM) relative to bottom seawater (~245μM). We were unable to detect reduced hydrocarbons, e.g. methane. Cell counts indicated the presence of roughly 2 x 10^4 cells per ml in all fluid samples, and DNA was extracted and amplified for the identification of both bacterial and archaeal community members. The utilization of ammonia, nitrate, dissolved inorganic carbon, and acetate was measured using stable isotopes, and oxygen consumption was monitored to provide an estimate of the rate of respiration per cell per day

  20. Optical analysis of suspended particles in the cerebrospinal fluid obtained by puncture from patients diagnosed with the disorders of cerebrospinal fluid (CSF) circulation

    NASA Astrophysics Data System (ADS)

    Staroń, Waldemar; Herbowski, Leszek; Gurgul, Henryk

    2007-04-01

    The goal of the work was to determine the values of cumulative parameters of the cerebrospinal fluid. Values of the parameters characterise statistical cerebrospinal fluid obtained by puncture from the patients diagnosed due to suspicion of normotensive hydrocephalus. The cerebrospinal fluid taken by puncture for the routine examinations carried out at the patients suspected of normotensive hydrocephalus was analysed. In the paper there are presented results of examinations of several dozens of puncture samples of the cerebrospinal fluid coming from various patients. Each sample was examined under the microscope and photographed in 20 randomly chosen places. On the basis of analysis of the pictures showing the area of 100 x 100μm, the selected cumulative parameters such as count, numerical density, field area and field perimeter were determined for each sample. Then the average value of the parameters was determined as well.

  1. Detection of Nitrobenzodiazepines and Their 7-Amino Metabolites in Oral Fluid.

    PubMed

    Vindenes, Vigdis; Strand, Dag Helge; Koksæter, Paul; Gjerde, Hallvard

    2016-05-01

    Clonazepam, nitrazepam and flunitrazepam are frequently used benzodiazepines, both as prescribed medication and as drugs of abuse. Little is, however, known about how these drugs are excreted in oral fluid. It has been claimed that the parent drugs are more likely to be detected in oral fluid than the 7-amino metabolites. The aim of this study was to investigate whether the parent drugs or the 7-amino metabolites of the nitrobenzodiazepines were most frequently detected in authentic oral fluid samples. Oral fluid samples were collected from patients undergoing opioid maintenance treatment. Cases where clonazepam, nitrazepam, flunitrazepam and/or their metabolites were detected were included. The samples were collected using the Intercept Oral Specimen Collection Device. A cutoff concentration of 1 nM (∼0.3 ng/mL) in oral fluid-buffer mixture was applied for all the substances. A total of 1,001 oral fluid samples were positive for clonazepam and/or 7-aminoclonazepam; both substances were detected in 707 samples, only the parent drug in 64 cases and only the metabolite in 230 cases. For nitrazepam, both substances were detected in 139 samples; only the parent drug in 16 cases and only the metabolite in 56 cases. Flunitrazepam only was not detected in any sample; both substances were detected in one of these cases, and only the metabolite in three cases. This study revealed that 7-amino metabolites were more likely to be detected in oral fluid than the parent drugs. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Torque Measurement of 3-DOF Haptic Master Operated by Controllable Electrorheological Fluid

    NASA Astrophysics Data System (ADS)

    Oh, Jong-Seok; Choi, Seung-Bok; Lee, Yang-Sub

    2015-02-01

    This work presents a torque measurement method of 3-degree-of-freedom (3-DOF) haptic master featuring controllable electrorheological (ER) fluid. In order to reflect the sense of an organ for a surgeon, the ER haptic master which can generate the repulsive torque of an organ is utilized as a remote controller for a surgery robot. Since accurate representation of organ feeling is essential for the success of the robot-assisted surgery, it is indispensable to develop a proper torque measurement method of 3-DOF ER haptic master. After describing the structural configuration of the haptic master, the torque models of ER spherical joint are mathematically derived based on the Bingham model of ER fluid. A new type of haptic device which has pitching, rolling, and yawing motions is then designed and manufactured using a spherical joint mechanism. Subsequently, the field-dependent parameters of the Bingham model are identified and generating repulsive torque according to applied electric field is measured. In addition, in order to verify the effectiveness of the proposed torque model, a comparative work between simulated and measured torques is undertaken.

  3. Sub-seafloor Processes and the Composition of Diffuse Hydrothermal Fluids

    NASA Astrophysics Data System (ADS)

    Butterfield, D. A.; Lilley, M. D.; Huber, J. A.; Baross, J. A.

    2002-12-01

    High-temperature water/rock reactions create the primary hydrothermal fluids that are diluted with cool, "crustal seawater" to produce low-temperature, diffuse hydrothermal vent fluids. By knowing the composition of each of the components that combine to produce diffuse fluids, one can compare the composition of calculated mixtures with the composition of sampled fluids, and thereby infer what chemical constituents have been affected by processes other than simple conservative mixing. Although there is always uncertainty in the composition of fluids from the sub-seafloor, some processes are significant enough to alter diffuse fluid compositions from the expected conservative mixtures of hot,primary fluid and "crustal seawater." When hydrothermal vents with a wide range of temperature are sampled, processes occurring in different thermal and chemical environments potentially can be discerned. At Axial Volcano (AV) on the Juan de Fuca ridge, methane clearly is produced in warm sub-seafloor environments at temperatures of ~ 100° or less. Based on culturing and phylogenetic analysis from the same water samples at AV, hyperthermophilic methanogens are present in water samples taken from vents ranging in temperature from 15 to 78° C. Ratios of hydrogen sulfide to pseudo-conservative tracers (dissolved silica or heat) at AV decrease when primary fluids are highly diluted with oxygenated seawater. Phylogenetic signatures of microbes closely related to sulfide-oxidizers are present in these same fluids. Hydrogen sulfide oxidation represents the dominant source of energy for chemosynthesis at AV, as in most hydrothermal systems, but a relatively small proportion of the total hydrogen sulfide available is actually oxidized, except at the very lowest temperatures.

  4. Boiling-induced formation of colloidal gold in black smoker hydrothermal fluids

    USGS Publications Warehouse

    Gartman, Amy; Hannington, Mark; Jamieson, John W.; Peterkin, Ben; Garbe-Schönberg, Dieter; Findlay, Alyssa J; Fuchs, Sebastian; Kwasnitschka, Tom

    2017-01-01

    Gold colloids occur in black smoker fluids from the Niua South hydrothermal vent field, Lau Basin (South Pacific Ocean), confirming the long-standing hypothesis that gold may undergo colloidal transport in hydrothermal fluids. Six black smoker vents, varying in temperature from 250 °C to 325 °C, were sampled; the 325 °C vent was boiling at the time of sampling and the 250 °C fluids were diffusely venting. Native gold particles ranging from <50 nm to 2 µm were identified in 4 of the fluid samples and were also observed to precipitate on the sampler during collection from the boiling vent. Total gold concentrations (dissolved and particulate) in the fluid samples range from 1.6 to 5.4 nM in the high-temperature, focused flow vents. Although the gold concentrations in the focused flow fluids are relatively high, they are lower than potential solubilities prior to boiling and indicate that precipitation was boiling induced, with sulfide lost upon boiling to exsolution and metal sulfide formation. Gold concentrations reach 26.7 nM in the 250 °C diffuse flow sample, and abundant native gold particles were also found in the fluids and associated sulfide chimney and are interpreted to be a product of colloid accumulation and growth following initial precipitation upon boiling. These results indicate that colloid-driven precipitation as a result of boiling, the persistence of colloids after boiling, and the accumulation of colloids in diffuse flow fluids are important mechanisms for the enrichment of gold in seafloor hydrothermal systems.

  5. Chromium content in the human hip joint tissues.

    PubMed

    Brodziak-Dopierała, Barbara; Kwapuliński, Jerzy; Sobczyk, Krzysztof; Wiechuła, Danuta

    2015-02-01

    Chromium has many important functions in the human body. For the osseous tissue, its role has not been clearly defined. This study was aimed at determining chromium content in hip joint tissues. A total of 91 hip joint samples were taken in this study, including 66 from females and 25 from males. The sample tissues were separated according to their anatomical parts. The chromium content was determined by the AAS method. The statistical analysis was performed with U Mann-Whitney's non-parametric test, P≤0.05. The overall chromium content in tissues of the hip joint in the study subjects was as follows: 5.73 µg/g in the articular cartilage, 5.33 µg/g in the cortical bone, 17.86 µg/g in the cancellous bone, 5.95 µg/g in the fragment of the cancellous bone from the intertrochanteric region, and 1.28 µg/g in the joint capsule. The chromium contents were observed in 2 group patients, it was 7.04 µg/g in people with osteoarthritis and 12.59 µg/g in people with fractures. The observed chromium content was highest in the cancellous bone and the lowest in the joint capsule. Chromium content was significantly different between the people with hip joint osteoarthritis and the people with femoral neck fractures. Copyright © 2015 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  6. Subsurface images of the Eastern Rift, Africa, from the joint inversion of body waves, surface waves and gravity: investigating the role of fluids in early-stage continental rifting

    NASA Astrophysics Data System (ADS)

    Roecker, S.; Ebinger, C.; Tiberi, C.; Mulibo, G.; Ferdinand-Wambura, R.; Mtelela, K.; Kianji, G.; Muzuka, A.; Gautier, S.; Albaric, J.; Peyrat, S.

    2017-08-01

    The Eastern Rift System (ERS) of northern Tanzania and southern Kenya, where a cratonic lithosphere is in the early stages of rifting, offers an ideal venue for investigating the roles of magma and other fluids in such an environment. To illuminate these roles, we jointly invert arrival times of locally recorded P and S body waves, phase delays of ambient noise generated Rayleigh waves and Bouguer anomalies from gravity observations to generate a 3-D image of P and S wave speeds in the upper 25 km of the crust. While joint inversion of gravity and arrival times requires a relationship between density and wave speeds, the improvement in resolution obtained by the combination of these disparate data sets serves to further constrain models, and reduce uncertainties. The most significant features in the 3-D model are (1) P and S wave speeds that are 10-15 per cent lower beneath the rift zone than in the surrounding regions, (2) a relatively high wave speed tabular feature located along the western edge of the Natron and Manyara rifts, and (3) low (∼1.71) values of Vp/Vs throughout the upper crust, with the lowest ratios along the boundaries of the rift zones. The low P and S wave speeds at mid-crustal levels beneath the rift valley are an expected consequence of active volcanism, and the tabular, high-wave speed feature is interpreted to be an uplifted footwall at the western edge of the rift. Given the high levels of CO2 outgassing observed at the surface along border fault zones, and the sensitivity of Vp/Vs to pore-fluid compressibility, we infer that the low Vp/Vs values in and around the rift zone are caused by the volcanic plumbing in the upper crust being suffused by a gaseous CO2 froth on top of a deeper, crystalline mush. The repository for molten rock is likely located in the lower crust and upper mantle, where the Vp/Vs ratios are significantly higher.

  7. Effects of Arg-Gly-Asp sequence peptide and hyperosmolarity on the permeability of interstitial matrix and fenestrated endothelium in joints.

    PubMed

    Poli, A; Mason, R M; Levick, J R

    2004-09-01

    The aims were to assess the contribution of arg-gly-asp (RGD) mediated cell integrin-matrix bonds to interstitial hydraulic resistance and to fenestrated endothelial permeability in joints. Joint fluid is generated by filtration from fenestrated capillaries and drains through a fibronectin-rich synovial intercellular matrix. The role of parenchymal cell-matrix bonding in determining tissue hydraulic resistance is unknown. The knee cavity of anesthetized rabbits was infused with saline or the competitive hexapeptide blocker GRGDTP, with or without added osmotic stress (600 mosm saline). Intra-articular pressure Pj, net trans-synovial drainage rate s, and the permeation of Evans blue-labeled albumin (EVA) from plasma into the joint cavity were measured. GRGDTP increased the hydraulic conductance of the synovial drainage pathway, ds/dPj, by 71% (p =.02, paired t test, n = 6 animals). Synovial plasma EVA clearance (control 7.1 +/- 0.8 microL h-1, mean +/- SEM, n = 15) was unaffected by GRGDTP (7.0 +/- 2.3 microL h(-1), n = 6) or hyperosmolarity (4.9 +/- 1.5 microL h(-1), n = 8) but was increased by GRGDTP and hyperosmolarity together (15.9 +/- 4.8 microL h(-1), n = 5) (p =.01, ANOVA). Changes in dPj/dt evoked by GRGDTP plus hyperosmolarity, but neither alone, demonstrated increased microvascular filtration into the joint cavity (p <.001, ANOVA), as did changes in fluid absorption from the infusion system at fixed Pj. RGD-mediated bonds between the parenchymal cells and interstitial polymers reduce the interstitial hydraulic conductance by 42%. This helps to retain the lubricating fluid inside a joint cavity. RGD-mediated bonds also support the macromolecular barrier function of fenestrated endothelium, but in vivo this is evident only in stressed endothelium (cf. in vitro).

  8. Detecting alcohol and illicit drugs in oral fluid samples collected from truck drivers in the state of São Paulo, Brazil.

    PubMed

    Yonamine, Mauricio; Sanches, Livia Rentas; Paranhos, Beatriz Aparecida Passos Bismara; de Almeida, Rafael Menck; Andreuccetti, Gabriel; Leyton, Vilma

    2013-01-01

    Alcohol and drug use by truck drivers is a current problem in Brazil. Though there is evidence that alcohol consumption is occurring in higher proportions, the use of stimulant drugs to avoid fatigue and to maintain the work schedule has also been reported. The purpose of this study was to estimate the incidence of alcohol and illicit drug use among truck drivers on São Paulo state roads. São Paulo is the most populous state in Brazil and has the largest industrial park and economic production in the country. Data were assessed not only using a questionnaire but also, and more reliably, through toxicological analysis of oral fluid samples. Between the years 2002 and 2008, 1250 oral fluid samples were collected from truck drivers on the roads during morning hours. The samples were tested for the presence of alcohol, cocaine, tetrahydrocannabinol (THC), and amphetamine/methamphetamine. A previously published, validated gas chromatographic (gas chromatography-flame ionization detection and gas chromatography-mass spectrometry) method was applied to the samples for alcohol and drug detection. Of the total analyzed samples, 3.1 percent (n = 39) were positive: 1.44 percent (n = 18) were positive for alcohol, 0.64 percent (n = 8) for amphetamines, 0.56 percent (n = 7) for cocaine, and 0.40 percent (n = 5) for THC. In one case, cocaine and THC were detected. The results are indicative of the extent of alcohol and drug use by truck drivers in the state of São Paulo, Brazil. This research provides evidence that not only alcohol but also illicit drug use is a real problem among professional drivers. The use of these substances should be controlled to better promote safe driving conditions on Brazilian roads.

  9. Invasion of Hydrous Fluids Predates Kimberlite Formation

    NASA Astrophysics Data System (ADS)

    Kopylova, M. G.; Wang, Q.; Smith, E. M.

    2017-12-01

    Petrological observations on diamonds and peridotite xenoliths in kimberlites point towards an influx of hydrous metasomatic fluids shortly predating kimberlite formation. Diamonds may grow at different times within the same segment of the cratonic mantle, and diamonds that form shortly before (<5-7 My) the kimberlite entrainment host the more hydrous fluid inclusions. Younger fibrous diamonds typically contain 10-25 wt.% water in fluid inclusions, while older octahedrally-grown diamonds host "dry" N2-CO2 fluids. Our recent studies of fluids in diamond now show that many different kinds of diamonds can contain fluid inclusions. Specifically, we found a new way to observe and analyze fluids in octahedrally-grown, non-fibrous diamonds by examining healed fractures. This is a new textural context for fluid inclusions that reveals a valuable physical record of infiltrating mantle fluids, that postdate diamond growth, but equilibrate within the diamond stability field at depths beyond 150 km. Another sign of the aqueous fluids influx is the formation of distinct peridotite textures shortly predating the kimberlite. Kimberlites entrain peridotite xenoliths with several types of textures: older coarse metamorphic textures and younger, sheared textures. The preserved contrast in grain sizes between porphyroclasts and neoblasts in sheared peridotites constrain the maximum duration of annealing. Experimental estimates of the annealing time vary from 7x107 sec (2 years) to 106 years (1 My) depending on olivine hydration, strain rate, pressure, temperature and, ultimately, the annealing mechanism. Kimberlite sampling of sheared peridotites from the lithosphere- asthenosphere boundary (LAB) implies their formation no earlier than 1 My prior to the kimberlite ascent. Water contents of olivine measured by FTIR spectrometry using polarized light demonstrated contrasting hydration of coarse and sheared samples. Olivine from sheared peridotite samples has the average water content

  10. Geomechanical Response of Jointed Caprock During CO2 Geological Sequestration

    NASA Astrophysics Data System (ADS)

    Newell, P.; Martinez, M. J.; Bishop, J. E.

    2014-12-01

    Geological sequestration of CO2 refers to the injection of supercritical CO2 into deep reservoirs trapped beneath a low-permeability caprock formation. Maintaining caprock integrity during the injection process is the most important factor for a successful injection. In this work we evaluate the potential for jointed caprock during injection scenarios using coupled three-dimensional multiphase flow and geomechanics modeling. Evaluation of jointed/fractured caprock systems is of particular concern to CO2 sequestration because creation or reactivation of joints (mechanical damage) can lead to enhanced pathways for leakage. In this work, we use an equivalent continuum approach to account for the joints within the caprock. Joint's aperture and non-linear stiffness of the caprock will be updated dynamically based on the effective normal stress. Effective permeability field will be updated based on the joints' aperture creating an anisotropic permeability field throughout the caprock. This feature would add another coupling between the solid and fluid in addition to basic Terzaghi's effective stress concept. In this study, we evaluate the impact of the joint's orientation and geometry of caprock and reservoir layers on geomechanical response of the CO2 geological systems. This work is supported as part of the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Award Number DE-SC0001114. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  11. Cytology exam of pleural fluid

    MedlinePlus

    ... the lungs. This area is called the pleural space. Cytology means the study of cells. ... A sample of fluid from the pleural space is needed. The sample is taken using a procedure called thoracentesis . The procedure is done in the following way: You sit on a ...

  12. Brucella melitensis prosthetic joint infection in a traveller returning to the UK from Thailand: Case report and review of the literature.

    PubMed

    Lewis, Joseph M; Folb, Jonathan; Kalra, Sanjay; Squire, S Bertel; Taegtmeyer, Miriam; Beeching, Nick J

    Brucella spp. prosthetic joint infections are infrequently reported in the literature, particularly in returning travellers, and optimal treatment is unknown. We describe a prosthetic joint infection (PJI) caused by Brucella melitensis in a traveller returning to the UK from Thailand, which we believe to be the first detailed report of brucellosis in a traveller returning from this area. The 23 patients with Brucella-related PJI reported in the literature are summarised, together with our case. The diagnosis of Brucella-related PJI is difficult to make; only 30% of blood cultures and 75% of joint aspiration cultures were positive in the reported cases. Culture of intraoperative samples provides the best diagnostic yield. In the absence of radiological evidence of joint loosening, combination antimicrobial therapy alone may be appropriate treatment in the first instance; this was successful in 6/7 [86%] of patients, though small numbers of patients and the likelihood of reporting bias warrant caution in drawing any firm conclusions about optimal treatment. Aerosolisation of synovial fluid during joint aspiration procedures and nosocomial infection has been described. Brucella-related PJI should be considered in the differential of travellers returning from endemic areas with PJI, including Thailand. Personal protective equipment including fit tested filtering face piece-3 (FFP3) mask or equivalent is recommended for personnel carrying out joint aspiration when brucellosis is suspected. Travellers can reduce the risk of brucellosis by avoiding unpasteurised dairy products and animal contact (particularly on farms and abattoirs) in endemic areas and should be counselled regarding these risks as part of their pre-travel assessment. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. Conjugate Compressible Fluid Flow and Heat Transfer in Ducts

    NASA Technical Reports Server (NTRS)

    Cross, M. F.

    2011-01-01

    A computational approach to modeling transient, compressible fluid flow with heat transfer in long, narrow ducts is presented. The primary application of the model is for analyzing fluid flow and heat transfer in solid propellant rocket motor nozzle joints during motor start-up, but the approach is relevant to a wide range of analyses involving rapid pressurization and filling of ducts. Fluid flow is modeled through solution of the spatially one-dimensional, transient Euler equations. Source terms are included in the governing equations to account for the effects of wall friction and heat transfer. The equation solver is fully-implicit, thus providing greater flexibility than an explicit solver. This approach allows for resolution of pressure wave effects on the flow as well as for fast calculation of the steady-state solution when a quasi-steady approach is sufficient. Solution of the one-dimensional Euler equations with source terms significantly reduces computational run times compared to general purpose computational fluid dynamics packages solving the Navier-Stokes equations with resolved boundary layers. In addition, conjugate heat transfer is more readily implemented using the approach described in this paper than with most general purpose computational fluid dynamics packages. The compressible flow code has been integrated with a transient heat transfer solver to analyze heat transfer between the fluid and surrounding structure. Conjugate fluid flow and heat transfer solutions are presented. The author is unaware of any previous work available in the open literature which uses the same approach described in this paper.

  14. Analysis of cannabis in oral fluid specimens by GC-MS with automatic SPE.

    PubMed

    Choi, Hyeyoung; Baeck, Seungkyung; Kim, Eunmi; Lee, Sooyeun; Jang, Moonhee; Lee, Juseon; Choi, Hwakyung; Chung, Heesun

    2009-12-01

    Methamphetamine (MA) is the most commonly abused drug in Korea, followed by cannabis. Traditionally, MA analysis is carried out on both urine and hair samples and cannabis analysis in urine samples only. Despite the fact that oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing, its application has not been expanded to drug analysis in Korea. Oral fluid is easy to collect and handle and can provide an indication of recent drug abuse. In this study, we present an analytical method using GC-MS to determine tetrahydrocannabinol (THC) and its main metabolite 11-nor-delta9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in oral fluid. The validated method was applied to oral fluid samples collected from drug abuse suspects and the results were compared with those in urine. The stability of THC and THC-COOH in oral fluid stored in different containers was also investigated. Oral fluid specimens from 12 drug abuse suspects, submitted by the police, were collected by direct expectoration. The samples were screened with microplate ELISA. For confirmation they were extracted using automated SPE with mixed-mode cation exchange cartridge, derivatized and analyzed by GC-MS using selective ion monitoring (SIM). The concentrations ofTHC and THC-COOH in oral fluid showed a large variation and the results from oral fluid and urine samples from cannabis abusers did not show any correlation. Thus, detailed information about time interval between drug use and sample collection is needed to interpret the oral fluid results properly. In addition, further investigation about the detection time window ofTHC and THC-COOH in oral fluid is required to substitute oral fluid for urine in drug testing.

  15. Laser textured Co-Cr-Mo alloy stored chitosan/poly(ethylene glycol) composite applied on artificial joints lubrication.

    PubMed

    Lu, Hailin; Ren, Shanshan; Guo, Junde; Li, Yue; Li, Jianhui; Dong, Guangneng

    2017-09-01

    Arthroplasty brings the wear problems because of body fluid has poor performance as lubricant. Lubricant which is used in artificial joints will rapidly degrade and be absorbed by human body after injecting. To prolong the lubricant's effectiveness, this study prepared chitosan/poly(ethylene glycol) (CS/PEG) and textures to play a role in joint lubrication and wear protection. Chitosan (CS) and poly(ethylene glycol) which have biocompatibility and biodegradability properties can be used in human body. The tribological results shown that CS/PEG sol has excellent performance when this sol was composed by 2wt% CS and 30wt% PEG, the average friction coefficient below 0.016 under the condition of 30-90N load (pressure 4.2-12.6MPa). In this study, CS/PEG was added in the texture of artificial joints, then the surfaces of the CS/PEG formed gel via NaOH solidification effect. The CS/PEG gel film could prevent the CS/PEG sol from diluting in body fluid. Meanwhile, FT-IR, XRD, UV/vis and Raman spectra revealed that CS associated with PEG via hydrogen bond effect may form a particular structure, which leaded the good tribological performance. This study provides a new, simple and green approach to enhance tribological performances of artificial joints. Copyright © 2017. Published by Elsevier B.V.

  16. [Discrimination of varieties of brake fluid using visual-near infrared spectra].

    PubMed

    Jiang, Lu-lu; Tan, Li-hong; Qiu, Zheng-jun; Lu, Jiang-feng; He, Yong

    2008-06-01

    A new method was developed to fast discriminate brands of brake fluid by means of visual-near infrared spectroscopy. Five different brands of brake fluid were analyzed using a handheld near infrared spectrograph, manufactured by ASD Company, and 60 samples were gotten from each brand of brake fluid. The samples data were pretreated using average smoothing and standard normal variable method, and then analyzed using principal component analysis (PCA). A 2-dimensional plot was drawn based on the first and the second principal components, and the plot indicated that the clustering characteristic of different brake fluid is distinct. The foregoing 6 principal components were taken as input variable, and the band of brake fluid as output variable to build the discriminate model by stepwise discriminant analysis method. Two hundred twenty five samples selected randomly were used to create the model, and the rest 75 samples to verify the model. The result showed that the distinguishing rate was 94.67%, indicating that the method proposed in this paper has good performance in classification and discrimination. It provides a new way to fast discriminate different brands of brake fluid.

  17. Brachygnathia superior and degenerative joint disease: a new lethal syndrome in Angus calves.

    PubMed

    Jayo, M; Leipold, H W; Dennis, S M; Eldridge, F E

    1987-03-01

    Brachygnathia superior and generalized diarthrodial degenerative joint disease were seen in 17 related, purebred Angus calves ranging in age from 2 days to 4 months. Craniometrical studies revealed decreased maxillary and palatine bone lengths and increased cranial, skull, and facial indices. Radiological evaluation of major appendicular joints demonstrated lipping of the joint margins with osteophyte formation, sclerosis of subchondral bone, and narrowing of joint spaces. Synovial fluid evaluation indicated joint degeneration but no etiologic agent. Rheumatoid factor analysis of plasma was negative. Grossly, all major appendicular joints were defective including the atlanto-occipital articulation. Lesions ranged from loss of surface luster to erosions and deep ulcers with eburnation of the subchondral bone and secondary proliferative synovitis. Histological changes were degeneration of the articular cartilage matrix, chondrocyte necrosis, flaking and fibrillation, chondrone formation, erosions and ulcers of the articular cartilage with subchondral bone sclerosis, vascular invasion with fibrosis, and chronic, nonsuppurative, proliferative synovitis. Growth plates had defective chondrocyte proliferation and hypertrophy with aberrant ossification of calcified cartilaginous matrix. Histochemical analysis of cartilage and bone failed to incriminate which component was defective, glycosaminoglycan or collagen, but indicated different distribution or absence of one or the other. Genealogic studies revealed a genetic basis for the new defect.

  18. Thermally Conductive Metal-Tube/Carbon-Composite Joints

    NASA Technical Reports Server (NTRS)

    Copeland, Robert J.

    2004-01-01

    An improved method of fabricating joints between metal and carbon-fiber-based composite materials in lightweight radiators and heat sinks has been devised. Carbon-fiber-based composite materials have been used in such heat-transfer devices because they offer a combination of high thermal conductivity and low mass density. Metal tubes are typically used to carry heat-transfer fluids to and from such heat-transfer devices. The present fabrication method helps to ensure that the joints between the metal tubes and the composite-material parts in such heat-transfer devices have both (1) the relatively high thermal conductances needed for efficient transfer of heat and (2) the flexibility needed to accommodate differences among thermal expansions of dissimilar materials in operation over wide temperature ranges. Techniques used previously to join metal tubes with carbon-fiber-based composite parts have included press fitting and bonding with epoxy. Both of these prior techniques have been found to yield joints characterized by relatively high thermal resistances. The present method involves the use of a solder (63 percent Sn, 37 percent Pb) to form a highly thermally conductive joint between a metal tube and a carbon-fiber-based composite structure. Ordinarily, the large differences among the coefficients of thermal expansion of the metal tube, solder, and carbon-fiber-based composite would cause the solder to pull away from the composite upon post-fabrication cooldown from the molten state. In the present method, the structure of the solder is modified (see figure) to enable it to deform readily to accommodate the differential thermal expansion.

  19. A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints

    PubMed Central

    Chyr, Anthony; Qiu, Mingfeng; Speltz, Jared; Jacobsen, Ronald L.; Sanders, Anthony P.; Raeymaekers, Bart

    2014-01-01

    More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily as a result of polyethylene wear and wear debris incited disease. The current engineering paradigm to increase the longevity of prosthetic hip joints is to improve the mechanical properties of the polyethylene component, and to manufacture ultra-smooth articulating surfaces. In contrast, we show that adding a patterned microtexture to the ultra-smooth CoCr femoral head reduces friction when articulating with the polyethylene acetabular liner. The microtexture increases the load-carrying capacity and the thickness of the joint lubricant film, which reduces contact between the articulating surfaces. As a result, friction and wear is reduced. We have used a lubrication model to design the geometry of the patterned microtexture, and experimentally demonstrate reduced friction for the microtextured compared to conventional smooth surrogate prosthetic hip joints. PMID:25013240

  20. Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers.

    PubMed

    Boelch, Sebastian Philipp; Weissenberger, Manuel; Spohn, Frederik; Rudert, Maximilian; Luedemann, Martin

    2018-01-10

    Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip.

  1. Metabolic profiling of body fluids and multivariate data analysis.

    PubMed

    Trezzi, Jean-Pierre; Jäger, Christian; Galozzi, Sara; Barkovits, Katalin; Marcus, Katrin; Mollenhauer, Brit; Hiller, Karsten

    2017-01-01

    Metabolome analyses of body fluids are challenging due pre-analytical variations, such as pre-processing delay and temperature, and constant dynamical changes of biochemical processes within the samples. Therefore, proper sample handling starting from the time of collection up to the analysis is crucial to obtain high quality samples and reproducible results. A metabolomics analysis is divided into 4 main steps: 1) Sample collection, 2) Metabolite extraction, 3) Data acquisition and 4) Data analysis. Here, we describe a protocol for gas chromatography coupled to mass spectrometry (GC-MS) based metabolic analysis for biological matrices, especially body fluids. This protocol can be applied on blood serum/plasma, saliva and cerebrospinal fluid (CSF) samples of humans and other vertebrates. It covers sample collection, sample pre-processing, metabolite extraction, GC-MS measurement and guidelines for the subsequent data analysis. Advantages of this protocol include: •Robust and reproducible metabolomics results, taking into account pre-analytical variations that may occur during the sampling process•Small sample volume required•Rapid and cost-effective processing of biological samples•Logistic regression based determination of biomarker signatures for in-depth data analysis.

  2. Large-deviation joint statistics of the finite-time Lyapunov spectrum in isotropic turbulence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Perry L., E-mail: pjohns86@jhu.edu; Meneveau, Charles

    2015-08-15

    One of the hallmarks of turbulent flows is the chaotic behavior of fluid particle paths with exponentially growing separation among them while their distance does not exceed the viscous range. The maximal (positive) Lyapunov exponent represents the average strength of the exponential growth rate, while fluctuations in the rate of growth are characterized by the finite-time Lyapunov exponents (FTLEs). In the last decade or so, the notion of Lagrangian coherent structures (which are often computed using FTLEs) has gained attention as a tool for visualizing coherent trajectory patterns in a flow and distinguishing regions of the flow with different mixingmore » properties. A quantitative statistical characterization of FTLEs can be accomplished using the statistical theory of large deviations, based on the so-called Cramér function. To obtain the Cramér function from data, we use both the method based on measuring moments and measuring histograms and introduce a finite-size correction to the histogram-based method. We generalize the existing univariate formalism to the joint distributions of the two FTLEs needed to fully specify the Lyapunov spectrum in 3D flows. The joint Cramér function of turbulence is measured from two direct numerical simulation datasets of isotropic turbulence. Results are compared with joint statistics of FTLEs computed using only the symmetric part of the velocity gradient tensor, as well as with joint statistics of instantaneous strain-rate eigenvalues. When using only the strain contribution of the velocity gradient, the maximal FTLE nearly doubles in magnitude, highlighting the role of rotation in de-correlating the fluid deformations along particle paths. We also extend the large-deviation theory to study the statistics of the ratio of FTLEs. The most likely ratio of the FTLEs λ{sub 1} : λ{sub 2} : λ{sub 3} is shown to be about 4:1:−5, compared to about 8:3:−11 when using only the strain-rate tensor for calculating fluid volume

  3. Demonstration of antibodies to collagen and of collagen-anticollagen immune complexes in rheumatoid arthritis synovial fluids

    PubMed Central

    Menzel, J.; Steffen, C.; Kolarz, G.; Eberl, R.; Frank, O.; Thumb, N.

    1976-01-01

    Menzel, J., Steffen, C., Kolarz, G., Eberl, R., Frank, O., and Thumb, N. (1976).Annals of the Rheumatic Diseases, 35, 446-450. Demonstration of antibodies to collagen and of collagen-anticollagen immune complexes in rheumatoid arthritis synovial fluids. Twenty-nine synovial fluids from patients with rheumatoid arthritis (RA) and 10 synovial fluids from patients with other joint diseases were investigated with regard to the presence of antibodies to denatured human collagen and of collagen-anticollagen immune complexes. 12 of the 29 RA synovial fluids showed anticollagen titres from 1: 16 to 1: 512 in passive haemagglutination. Only one patient in the group with no arthritis had a significant anticollagen titre of 1: 32. Digestion of the synovial fluids with bacterial collagenase resulted in an anticollagen titre increase from two to four dilution steps in 9 of the RA fluids, while 6 previously negative RA synovial fluids showed anticollagen titres from 1: 32 to 1: 128 after digestion with collagenase. These results indicate the existence of collagen-anticollagen immune complexes in 15 of the 29 RA synovial fluids investigated. PMID:185972

  4. Experimental studies of glued Aluminum-glass joints

    NASA Astrophysics Data System (ADS)

    Ligaj, B.; Wirwicki, M.; Karolewska, K.; Jasińska, A.

    2018-04-01

    Glued steel-glass or aluminum-glass joints are to be found, among other things, in vehicles (cars, buses, trains, trams) as windscreen assembly pieces for the supporting structure. For the purposes of the experiments, samples were made in which the top beam was made of the AW-2017A aluminum alloy and the bottom beam was made of thermally reinforced soda-lime glass whereas the glued joints were made of one-component polyurethane glue Körapur 175. The tests were performed under four-point bending conditions at monotonic incremental bending moment values on the Instron 5965 durability machine. The experimental study of the durability of glued joints under four-point bending conditions with the monotonic incremental bending moment allows to determine the values of stresses, whose value is related to initiation of damage of the tested joint.

  5. Utility of percutaneous joint aspiration and synovial biopsy in identifying culture-positive infected hip arthroplasty.

    PubMed

    Cross, M Connor; Kransdorf, Mark J; Chivers, F Spencer; Lorans, Roxanne; Roberts, Catherine C; Schwartz, Adam J; Beauchamp, Christopher P

    2014-02-01

    Percutaneous synovial biopsy has recently been reported to have a high diagnostic value in the preoperative identification of periprosthetic infection of the hip. We report our experience with this technique in the evaluation of patients undergoing revision hip arthroplasty, comparing results of preoperative synovial biopsy with joint aspiration in identifying an infected hip arthroplasty by bacteriological analysis. We retrospectively reviewed the results of the 110 most recent revision hip arthroplasties in which preoperative synovial biopsy and joint aspiration were both performed. Revision surgery for these patients occurred during the period from September 2005 to March 2012. Using this study group, results from preoperative cultures were compared with preoperative laboratory studies and the results of intraoperative cultures. Synovial aspiration was done using an 18- or 20-gauge spinal needle. Synovial biopsy was done coaxially following aspiration using a 22-gauge Chiba needle or 21-gauge Sure-Cut needle. Standard microbiological analysis was performed on preoperative synovial fluid aspirate and synovial biopsy. Intraoperative tissue biopsy bacteriological analysis results at surgical revision were accepted as the "gold standard" for the presence or absence of infection. Seventeen of 110 (15 %) of patients had intraoperative culture-positive periprosthetic infection. Of these 17 cases, there were ten cases where either the synovial fluid aspiration and/or the synovial biopsy were true positive (sensitivity of 59 %, specificity of 100 %, positive predictive value of 100 % and accuracy of 94 %). There were seven cases where aspiration and biopsy results were both falsely negative, but no false-positive results. Similar results were found for synovial fluid aspiration alone. The results of synovial biopsy alone resulted in the identification of seven infected joints with no false-positive result (sensitivity of 41 %, specificity of 100 %, positive

  6. Characterization of endocannabinoids and related acylethanolamides in the synovial fluid of dogs with osteoarthritis: a pilot study.

    PubMed

    Valastro, Carmela; Campanile, Debora; Marinaro, Mariarosaria; Franchini, Delia; Piscitelli, Fabiana; Verde, Roberta; Di Marzo, Vincenzo; Di Bello, Antonio

    2017-11-06

    Cannabis-based drugs have been shown to be effective in inflammatory diseases. A number of endocannabinoids including N- arachidonoylethanolamide (anandamide, AEA) and 2-arachidonyl glycerol (2-AG) with activity at the cannabinoid receptors (CBR) CBR1 and CBR2, have been identified. Other structurally related endogenous fatty acid compounds such as oleoylethanolamide (OEA) and palmitoyl ethanolamide (PEA) have been identified in biological tissues. These compounds do not bind to CBR but might be involved in facilitating the actions of directly acting endocannabinoids and thus are commonly termed "entourage" compounds due to their ability to modulate the endocannabinoid system. The aim of this study was to evaluate the presence of endocannabinoids and entourage compounds in the synovial fluid of dogs with osteoarthritis subjected to arthrotomy of the knee joint. Cytokines and cytology were studied as well. AEA, 2-AG, OEA and PEA were all present in the synovial fluid of arthritic knees and in the contralateral joints; in addition, a significant increase of OEA and 2AG levels were noted in SF from OA knees when compared to the contralateral joints. The identification and quantification of endocannabinoids and entourage compounds levels in synovial fluids from dogs with OA of the knee is reported for the first time. Our data are instrumental for future studies involving a greater number of dogs. Cannabinoids represent an emerging and innovative pharmacological tool for the treatment of OA and further studies are warranted to evaluate the effectiveness of cannabinoids in veterinary medicine.

  7. Performance Analysis of a Self-Propelling Flat Plate Fin with Joint Compliance

    NASA Astrophysics Data System (ADS)

    Reddy, N. Srinivasa; Sen, Soumen; Pal, Sumit; Shome, Sankar Nath

    2017-12-01

    Fish fin muscles are compliant and they regulate the stiffness to suit different swimming conditions. This article attempts to understand the significance of presence of compliance in fin muscle with help of a flexible joint flat plate fin model. Blade element method is employed to model hydrodynamics and to compute the forces of interaction during motion of the plate within fluid. The dynamic model of self-propelling fin is developed through multi-body dynamics approach considering the hydrodynamic forces as external forces acting on the fin. The derived hydrodynamic model is validated with experiments on rigid flat plate fin. The effect of the joint stiffness and flapping frequency on the propulsion speed and efficiency is investigated through simulations using the derived and validated model. The propulsion efficiency is found to be highly influenced by the joint stiffness at a given flapping frequency. The fin attained maximum propulsion efficiency when the joint stiffness is tuned to a value at which flapping frequency matches near natural frequency of the fin. At this tuned joint stiffness and flapping frequency, the resulted Strouhal numbers are observed to fall within the optimum range (0.2 to 0.4) for maximized propulsion efficiency of flying birds and swimming aquatic animals reported in literature.

  8. Detection time for THC in oral fluid after frequent cannabis smoking.

    PubMed

    Andås, Hilde T; Krabseth, Hege-Merete; Enger, Asle; Marcussen, Bjarne N; Haneborg, An-Magritt; Christophersen, Asbjørg S; Vindenes, Vigdis; Øiestad, Elisabeth L

    2014-12-01

    The use of oral fluid for detecting drugs of abuse has become increasingly more frequent. Few studies have, however, investigated the detection times for drugs of abuse in oral fluid, compared with that of in urine or in blood. Cannabis is the world's most widely used drug of abuse, and the detection times for cannabis, in different types of matrixes, are therefore important information to the laboratories or institutions performing and evaluating drugs of abuse analyses. It is well known that frequent use of high dosages of cannabis, for longer periods of time, might lead to prolonged detection times for THC-COOH in urine. Cannabis intake is detected in oral fluid as THC, and a positive finding is considered to be a result of recent smoking, although some studies have already reported longer detection times. The aim of this study was to investigate the detection time for THC in oral fluid, collected from drug addicts admitted for detoxification. Findings in oral fluid were compared with findings in urine, among 26 patients admitted to a closed detoxification unit. The study, being the first in doing so, describes the concentration-time profiles for THC in oral fluid among chronic cannabis users, during monitored abstinence, using the Intercept collection kit. The study also includes the concentration-time profiles for creatinine-corrected THC-COOH ratios in urine samples, included to monitor for the possibility of new intakes. THC was detected in oral fluid collected from 11 of the 26 patients in the study. The elimination curves for THC in oral fluid revealed that negative samples could be interspersed among positive samples several days after cessation, whereas the THC-COOH concentrations in urine were decreasing. THC was, in this study, detected in oral fluid for up to 8 days after admission. The study shows that frequent use of high dosages of cannabis may lead to prolonged detection times, and that positive samples can be interspersed among negative samples

  9. Hydraulic Properties of Fractured Rock Samples at In-Situ Conditions - Insights from Lab Experiments Using X-Ray Tomography

    NASA Astrophysics Data System (ADS)

    Nehler, Mathias; Stöckhert, Ferdinand; Duda, Mandy; Renner, Jörg; Bracke, Rolf

    2017-04-01

    The hydraulic properties of low-porosity rock formations are controlled by the geometry of open fractures, joints and faults. Aperture, surface roughness, accessible length, and thus, the volume available for fluids associated of such interfaces are strongly affected by their state of stress. Moreover, these properties may evolve with time in particular due to processes involving chemically active fluids. Understanding the physico-chemical interactions of rocks with fluids at reservoir conditions will help to predict the long-term reservoir development and to increase the efficiency of geothermal power plants. We designed an x-ray transparent flow-through cell. Confining pressure can be up to 50 MPa and pore fluid can currently be circulated through the sample with pressures of up to 25 MPa. All wetted parts are made of PEEK to avoid corrosion when using highly saline fluids. Laboratory experiments were performed to investigate hydraulic properties of fractured low-porosity samples under reservoir conditions while x-rays transmit the sample. The cell is placed inside a µCT scanner with a 225 kV multifocal x-ray tube for high resolution x-ray tomography. Samples measure 10 mm in diameter and 25 mm in length resulting in a voxel resolution of approximately 10 µm. Samples with single natural as well as artificial fractures were subjected to various confining pressures ranging from 2.5 MPa to 25 MPa. At each pressure level, effective permeability was determined from steady-state flow relying on Darcy's law. In addition, a full 3D image was recorded by the µCT scanner to gain information on the fracture aperture and geometry. Subvolumes (400x400x400 voxels) of the images were analyzed to reduce computational cost. The subvolumes were filtered in 3D with an edge preserving non-local means filter. Further quantification algorithms were implemented in Matlab. Segmentation into pore space and minerals was done automatically for all datasets by a peak finder algorithm

  10. Accelerated Comparative Fatigue Strength Testing of Belt Adhesive Joints

    NASA Astrophysics Data System (ADS)

    Bajda, Miroslaw; Blazej, Ryszard; Jurdziak, Leszek

    2017-12-01

    Belt joints are the weakest link in the serial structure that creates an endless loop of spliced belt segments. This affects not only the lower strength of adhesive joints of textile belts in comparison to vulcanized splices, but also the replacement of traditional glues to more ecological but with other strength parameters. This is reflected in the lowered durability of adhesive joints, which in underground coal mines is nearly twice shorter than the operating time of belts. Vulcanized splices require high precision in performance, they need long time to achieve cross-linking of the friction mixture and, above all, they require specialized equipment (vulcanization press) which is not readily available and often takes much time to be delivered down, which means reduced mining output or even downtime. All this reduces the reliability and durability of adhesive joints. In addition, due to the consolidation on the Polish coal market, mines are joined into large economic units serviced by a smaller number of processing plants. The consequence is to extend the transport routes downstream and increase reliability requirements. The greater number of conveyors in the chain reduces reliability of supply and increases production losses. With high fixed costs of underground mines, the reduction in mining output is reflected in the increase in unit costs, and this at low coal prices on the market can mean substantial losses for mines. The paper describes the comparative study of fatigue strength of shortened samples of adhesive joints conducted to compare many different variants of joints (various adhesives and materials). Shortened samples were exposed to accelerated fatigue in the usually long-lasting dynamic studies, allowing more variants to be tested at the same time. High correlation between the results obtained for shortened (100 mm) and traditional full-length (3×250 mm) samples renders accelerated tests possible.

  11. Joint Ventures: The Promise, Power and Performance of Partnering.

    ERIC Educational Resources Information Center

    Francisco, Grace; Hannah, Kathryn Covier; Keller, Shelly G.; Waters, Joan; Wong, Patricia M. Y.

    This document provides case studies that represent a sampling of successful public library joint ventures in California and other U.S. cities and counties. Chapter 1 defines what a partnership is and how a joint venture differs from a partnership. It also describes the benefits of partnering, the knowledge, attitude, and skills required, and how…

  12. Enantioselective simultaneous analysis of selected pharmaceuticals in environmental samples by ultrahigh performance supercritical fluid based chromatography tandem mass spectrometry.

    PubMed

    Camacho-Muñoz, Dolores; Kasprzyk-Hordern, Barbara; Thomas, Kevin V

    2016-08-31

    In order to assess the true impact of each single enantiomer of pharmacologically active compounds (PACs) in the environment, highly efficient, fast and sensitive analytical methods are needed. For the first time this paper focuses on the use of ultrahigh performance supercritical fluid based chromatography coupled to a triple quadrupole mass spectrometer to develop multi-residue enantioselective methods for chiral PACs in environmental matrices. This technique exploits the advantages of supercritical fluid chromatography, ultrahigh performance liquid chromatography and mass spectrometry. Two coated modified 2.5 μm-polysaccharide-based chiral stationary phases were investigated: an amylose tris-3,5-dimethylphenylcarbamate column and a cellulose tris-3-chloro-4-methylphenylcarbamate column. The effect of different chromatographic variables on chiral recognition is highlighted. This novel approach resulted in the baseline resolution of 13 enantiomers PACs (aminorex, carprofen, chloramphenicol, 3-N-dechloroethylifosfamide, flurbiprofen, 2-hydroxyibuprofen, ifosfamide, imazalil, naproxen, ofloxacin, omeprazole, praziquantel and tetramisole) and partial resolution of 2 enantiomers PACs (ibuprofen and indoprofen) under fast-gradient conditions (<10 min analysis time). The overall performance of the methods was satisfactory. The applicability of the methods was tested on influent and effluent wastewater samples. To the best of our knowledge, this is the first feasibility study on the simultaneous separation of chemically diverse chiral PACs in environmental matrices using ultrahigh performance supercritical fluid based chromatography coupled with tandem mass spectrometry. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Development and field application of a 6-bottle serial gas-tight fluid sampler for collecting seafloor cold seep and hydrothermal vent fluids with autonomous operation capability

    NASA Astrophysics Data System (ADS)

    Wu, S.; Ding, K.; Yang, C.; Seyfried, W. E., Jr.; Tan, C.; Schaen, A. T.; Luhmann, A. J.

    2014-12-01

    A 6-bottle serial gas-tight sampler (so-called "six-shooter") was developed for application with deep-sea vent fluids. The new device is composed of a custom-made 6-channel valve manifold and six sampling bottles which are circularly distributed around the valve manifold. Each valve channel consists of a high-pressure titanium cartridge valve and a motor-driven actuator. A sampling snorkel is connected to the inlet of the manifold that delivers the incoming fluid to different bottles. Each sampling bottle has a 160 ml-volume chamber and an accumulator chamber inside where compressed nitrogen is used to maintain the sample at near in-situ pressure. An electronics chamber that is located at the center of the sampler is used to carry out all sampling operations, autonomously, if desired. The sampler is of a compact circular configuration with a diameter of 26 cm and a length of 54 cm. During the SVC cruise AT 26-12, the sampler was deployed by DSV2 Alvin at a cold seep site MC036 with a depth of 1090 m in the Gulf of Mexico. The sampler collected fluid samples automatically following the tidal cycle to monitor the potential impact of the tide cycle on the fluid chemistry of cold seep in a period of two day. During the cruise AT 26-17, the sampler was used with newly upgraded DSV2 Alvin three times at the hydrothermal vent sites along Axial Seamount and Main Endeavor Field on Juan de Fuca Ridge. During a 4-day deployment at Anemone diffuse site (Axial Caldera), the sampler was set to work in an autonomous mode to collect fluid samples according to the preset interval. During other dives, the sampler was manually controlled via ICL (Inductively Coupled Link) communication through the hull. Gas-tight fluid samples were collected from different hydrothermal vents with temperatures between 267 ℃ and 335 ℃ at the depth up to 2200 m. The field results indicate unique advantages of the design. It can be deployed in extended time period with remote operation or working

  14. CT and MR findings in synovial chondromatosis of the temporo-mandibular joint: our experience and review of literature.

    PubMed

    Testaverde, Lorenzo; Perrone, Anna; Caporali, Laura; Ermini, Antonella; Izzo, Luciano; D'Angeli, Ilaria; Impara, Luca; Mazza, Dario; Izzo, Paolo; Marini, Mario

    2011-06-01

    To compare Computed Tomography (CT) and Magnetic Resonance (MR) features and their diagnostic potential in the assessment of Synovial Chondromatosis (SC) of the Temporo-Mandibular Joint (TMJ). Eight patients with symptoms and signs compatible with dysfunctional disorders of the TMJ underwent CT and MR scan. We considered the following parameters: soft tissue involvement (disk included), osteostructural alterations of the joints, loose bodies and intra-articular fluid. These parameters were evaluated separately by two radiologists with a "double blinded method" and then, after agreement, definitive assessment of the parameters was given. CT and MR findings were compared. Histopathological results showed metaplastic synovia in all patients and therefore confirmed diagnosis of SC. MR resulted better than CT in the evaluation of all parameters except the osteostructural alterations of the joints, estimated with more accuracy by CT scan. CT scan is excellent to define bony surfaces of the articular joints and flogistic tissue but it fails in the detection of loose bodies when these are not yet calcified. MR scan therefore is the gold standard when SC is suspected since it can visualize loose bodies at early stage and also evaluate disk condition and eventual extra-articular tissues involvement. The use of T2-weighted images and contrast medium allows identifying intra-articular fluid, estimating its entity and discriminating from sinovial tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Ultrasound-guided approach to the cervical articular process joints in horses: a validation of the technique in cadavers.

    PubMed

    Purefoy Johnson, Jessica; Stack, John David; Rowan, Conor; Handel, Ian; O'Leary, John Mark

    2017-05-22

    To compare accuracy of the ultrasound-guided craniodorsal (CrD) approach with the dorsal (D) approach to the cervical articular process joints, and to evaluate the effect of the transducer, needle gauge, and operator experience. Cervical articular process joints from 14 cadaveric neck specimens were injected using either a D or CrD approach, a linear (13 MHx) or microconvex transducer (10 MHz), and an 18 or 20 gauge needle, by an experienced or inexperienced operator. Injectate consisted of an iodinated contrast material solution. Time taken for injection, number of redirects, and retrieval of synovial fluid were recorded. Accuracy was assessed using a scoring system for contrast seen on computed tomography (CT). The successful performance of intra-articular injections of contrast detected by CT using the D (61/68) and CrD (57/64) approaches was comparable. No significant effect of approach, transducer or needle gauge was observed on injection accuracy, time taken to perform injection, or number of redirects. The 18 gauge needle had a positive correlation with retrieval of synovial fluid. A positive learning curve was observed for the inexperienced operator. Both approaches to the cervical articular process joints were highly accurate. Ultrasound-guided injection of the cervical articular process joints is an easily-learnt technique for an inexperienced veterinarian. Either approach may be employed in the field with a high level of accuracy, using widely available equipment.

  16. High hydrostatic pressures in traumatic joints require elevated synovial capillary pressure probably associated with arteriolar vasodilatation.

    PubMed

    Ahlqvist, J; Harilainen, A; Aalto, K; Sarna, S; Lalla, M; Osterlund, K

    1994-11-01

    Three out of the four Starling pressures were determined at arthroscopy of traumatic effusions of the knee. The range of the joint fluid hydrostatic pressure Pjoint was 5-83 cmH2O (0.5-8.1 kPa, 4-61 mmHg), that of the colloid osmotic pressure difference COPplasma-COPjoint 0-21.7 cmH2O. In 11 of 15 cases the sum Pjoint+COP difference exceeded 32.6 cmH2O (3.19 kPa, 24 mmHg), a high estimate of average capillary pressure at the level of the heart. The number of 'exceeding' cases was 8/15 if only 80% of the COP difference was considered effective. Pjoint and the COP difference oppose filtration of fluid from plasma into joints, indicating that mean capillary pressure, the only Starling pressure not determined, was elevated unless the effusions were being resorbed back into the blood. The findings can be explained by tamponade compensated by arteriolar vasodilatation, suspected to be metabolically mediated.

  17. Identification of dendritic cells in the blood and synovial fluid of children with Juvenile Idiopathic Arthritis.

    PubMed

    Tabarkiewicz, Jacek; Postępski, Jacek; Olesińska, Edyta; Roliński, Jacek; Tuszkiewicz-Misztal, Ewa

    2011-01-01

    Childhood chronic arthritis of unknown etiology is known collectively as juvenile idiopathic arthritis (JIA) and consists of heterogeneous subtypes with unique clinical patterns of disease. JIA is the commonest rheumatic disease in children and may still result in significant disability, with joint deformity, growth impairment, and persistence of active arthritis into adulthood. Basic research is rather focused on rheumatoid arthritis, and this lead to small number of publications considering JIA. In this study we examine, by flow cytometry, the expression of dendritic cells (DCs) in the peripheral blood and synovial fluid of children with active JIA in a group of 220 patients. We reveal a significant decrease in the percentage of immature DCs in the blood of patients compared to control children. Surprisingly, we found higher percentages of mature circulating dendritic cells. Both populations of DCs, immature and mature, were accumulated in patients' synovial fluid. We also confirmed the presence of CD206+/CD209+ in JIA samples, which can represent a population of macrophages with dendritic cells morphology. Our results support the thesis that dendritic cells are crucial in the induction and maintenance of autoimmune response and local inflammation during juvenile idiopathic arthritis.

  18. Substitute fluid examinations for liquid manure

    NASA Astrophysics Data System (ADS)

    Schrader, Kevin; Riedel, Marco; Eichert, Helmut

    For the farming industry it is essential to use liquid manure as natural fertilizer. Through new agricultural regulation 2015 in Germany the industry must develop new liquid manure spreader systems because the ammonia and methane emission are limited. In a research project the University of Applied Sciences Zwickau and some other industry partners will develop such a new innovative liquid manure spreader. The new liquid manure spreader should use pulsating air to distribute the liquid manure exactly. The pulsating air, which flows through the pipelines, should be analysed at a test station. For examinations at this test station it is important to find another substitute fluid because liquid manure smells strong, is not transparent and is also not homogeneous enough for scientific investigations. Furthermore it is important to ensure that the substitute fluid is, like liquid manure, a non-Newtonian fluid. The substitute fluid must be a shear-thinning substance - this means the viscosity decrease at higher shear rate. Many different samples like soap-water-farragoes, jelly-water-farragoes, agar-water-farragoes, soap-ethanol-farragoes and more are, for the project, examined in regard of their physical properties to find the best substitute fluid. The samples are examined at the rotational viscometer for viscosity at various shear rates and then compared with the viscosity values of liquid manure.

  19. MEPAG Recommendations for a 2018 Mars Sample Return Caching Lander - Sample Types, Number, and Sizes

    NASA Technical Reports Server (NTRS)

    Allen, Carlton C.

    2011-01-01

    The return to Earth of geological and atmospheric samples from the surface of Mars is among the highest priority objectives of planetary science. The MEPAG Mars Sample Return (MSR) End-to-End International Science Analysis Group (MEPAG E2E-iSAG) was chartered to propose scientific objectives and priorities for returned sample science, and to map out the implications of these priorities, including for the proposed joint ESA-NASA 2018 mission that would be tasked with the crucial job of collecting and caching the samples. The E2E-iSAG identified four overarching scientific aims that relate to understanding: (A) the potential for life and its pre-biotic context, (B) the geologic processes that have affected the martian surface, (C) planetary evolution of Mars and its atmosphere, (D) potential for future human exploration. The types of samples deemed most likely to achieve the science objectives are, in priority order: (1A). Subaqueous or hydrothermal sediments (1B). Hydrothermally altered rocks or low temperature fluid-altered rocks (equal priority) (2). Unaltered igneous rocks (3). Regolith, including airfall dust (4). Present-day atmosphere and samples of sedimentary-igneous rocks containing ancient trapped atmosphere Collection of geologically well-characterized sample suites would add considerable value to interpretations of all collected rocks. To achieve this, the total number of rock samples should be about 30-40. In order to evaluate the size of individual samples required to meet the science objectives, the E2E-iSAG reviewed the analytical methods that would likely be applied to the returned samples by preliminary examination teams, for planetary protection (i.e., life detection, biohazard assessment) and, after distribution, by individual investigators. It was concluded that sample size should be sufficient to perform all high-priority analyses in triplicate. In keeping with long-established curatorial practice of extraterrestrial material, at least 40% by

  20. Correlation of prostaglandin E2 concentrations in synovial fluid with ground reaction forces and clinical variables for pain or inflammation in dogs with osteoarthritis induced by transection of the cranial cruciate ligament.

    PubMed

    Trumble, Troy N; Billinghurst, R Clark; McIlwraith, C Wayne

    2004-09-01

    To evaluate the temporal pattern of prostaglandin (PG) E2 concentrations in synovial fluid after transection of the cranial cruciate ligament (CCL) in dogs and to correlate PGE2 concentrations with ground reaction forces and subjective clinical variables for lameness or pain. 19 purpose-bred adult male Walker Hounds. Force plate measurements, subjective clinical analysis of pain or lameness, and samples of synovial fluid were obtained before (baseline) and at various time points after arthroscopic transection of the right CCL. Concentrations of PGE2 were measured in synovial fluid samples, and the PGE2 concentrations were correlated with ground reaction forces and clinical variables. The PGE2 concentration increased significantly above the baseline value throughout the entire study, peaking 14 days after transection. Peak vertical force and vertical impulse significantly decreased by day 14 after transection, followed by an increase over time without returning to baseline values. All clinical variables (eg, lameness, degree of weight bearing, joint extension, cumulative pain score, effusion score, and total protein content of synovial fluid, except for WBC count in synovial fluid) increased significantly above baseline values. Significant negative correlations were detected between PGE2 concentrations and peak vertical force (r, -0.5720) and vertical impulse (r, -0.4618), and significant positive correlations were detected between PGE2 concentrations and the subjective lameness score (r, 0.5016) and effusion score (r, 0.6817). Assessment of the acute inflammatory process by measurement of PGE2 concentrations in synovial fluid may be correlated with the amount of pain or lameness in dogs.

  1. Rapid diagnosis of cryptococcal meningitis by use of lateral flow assay on cerebrospinal fluid samples: influence of the high-dose "hook" effect.

    PubMed

    Lourens, Adré; Jarvis, Joseph N; Meintjes, Graeme; Samuel, Catherine M

    2014-12-01

    Cryptococcal meningitis is the most frequent cause of meningitis and a major cause of mortality in HIV-infected adults in Africa. This study evaluated the performance of the lateral flow assay (LFA) on cerebrospinal fluid (CSF) samples for the diagnosis of cryptococcal meningitis against that of existing diagnostic tests. LFA performed on 465 undiluted CSF samples had a sensitivity of 91%. When the LFA was paired with Gram staining, a sensitivity of 100% was achieved after implementation of a dilution step for samples with negative LFA results and the presence of yeasts on microscopy. Microscopy is essential for preventing the reporting of false-negative results due to the high-dose "hook" effect. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. An investigation on mechanical properties of steel fibre reinforced for underwater welded joint

    NASA Astrophysics Data System (ADS)

    Navin, K.; Zakaria, M. S.; Zairi, S.

    2017-09-01

    Underwater pipelines are always exposed to water and have a high tendency to have corrosion especially on the welded joint. This research is about using fiber glass as steel fiber to coat the welded joint to determine the effectiveness in corrosion prevention of the welded joint. Number of coating is varied to determine the better number coating to coat the pipeline. Few samples were left without immersion in salt water and few samples are immersed into salt water with same salinity as sea water. The material sample is prepared in dog bone shape to enable to be used in Universal Tensile Machine (UTM). The material prepared is left immersed for recommended time and tested in Universal Tensile Machine. Upon analyzing the result, the result is used to determine the breakage point whether broken on the welded joint or different place and also the suitable number of coating to be used.

  3. A nondestructive, reproducible method of measuring joint reaction force at the distal radioulnar joint.

    PubMed

    Canham, Colin D; Schreck, Michael J; Maqsoodi, Noorullah; Doolittle, Madison; Olles, Mark; Elfar, John C

    2015-06-01

    To develop a nondestructive method of measuring distal radioulnar joint (DRUJ) joint reaction force (JRF) that preserves all periarticular soft tissues and more accurately reflects in vivo conditions. Eight fresh-frozen human cadaveric limbs were obtained. A threaded Steinmann pin was placed in the middle of the lateral side of the distal radius transverse to the DRUJ. A second pin was placed into the middle of the medial side of the distal ulna colinear to the distal radial pin. Specimens were mounted onto a tensile testing machine using a custom fixture. A uniaxial distracting force was applied across the DRUJ while force and displacement were simultaneously measured. Force-displacement curves were generated and a best-fit polynomial was solved to determine JRF. All force-displacement curves demonstrated an initial high slope where relatively large forces were required to distract the joint. This ended with an inflection point followed by a linear area with a low slope, where small increases in force generated larger amounts of distraction. Each sample was measured 3 times and there was high reproducibility between repeated measurements. The average baseline DRUJ JRF was 7.5 N (n = 8). This study describes a reproducible method of measuring DRUJ reaction forces that preserves all periarticular stabilizing structures. This technique of JRF measurement may also be suited for applications in the small joints of the wrist and hand. Changes in JRF can alter native joint mechanics and lead to pathology. Reliable methods of measuring these forces are important for determining how pathology and surgical interventions affect joint biomechanics. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Sodium inversion recovery MRI on the knee joint at 7 T with an optimal control pulse.

    PubMed

    Lee, Jae-Seung; Xia, Ding; Madelin, Guillaume; Regatte, Ravinder R

    2016-01-01

    In the field of sodium magnetic resonance imaging (MRI), inversion recovery (IR) is a convenient and popular method to select sodium in different environments. For the knee joint, IR has been used to suppress the signal from synovial fluids, which improves the correlation between the sodium signal and the concentration of glycosaminoglycans (GAGs) in cartilage tissues. For the better inversion of the magnetization vector under the spatial variations of the B0 and B1 fields, the IR sequence usually employ adiabatic pulses as the inversion pulse. On the other hand, it has been shown that RF shapes robust against the variations of the B0 and B1 fields can be generated by numerical optimization based on optimal control theory. In this work, we compare the performance of fluid-suppressed sodium MRI on the knee joint in vivo, between one implemented with an adiabatic pulse in the IR sequence and the other with the adiabatic pulse replaced by an optimal-control shaped pulse. While the optimal-control pulse reduces the RF power deposited to the body by 58%, the quality of fluid suppression and the signal level of sodium within cartilage are similar between two implementations. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Data-driven sensor placement from coherent fluid structures

    NASA Astrophysics Data System (ADS)

    Manohar, Krithika; Kaiser, Eurika; Brunton, Bingni W.; Kutz, J. Nathan; Brunton, Steven L.

    2017-11-01

    Optimal sensor placement is a central challenge in the prediction, estimation and control of fluid flows. We reinterpret sensor placement as optimizing discrete samples of coherent fluid structures for full state reconstruction. This permits a drastic reduction in the number of sensors required for faithful reconstruction, since complex fluid interactions can often be described by a small number of coherent structures. Our work optimizes point sensors using the pivoted matrix QR factorization to sample coherent structures directly computed from flow data. We apply this sampling technique in conjunction with various data-driven modal identification methods, including the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD). In contrast to POD-based sensors, DMD demonstrably enables the optimization of sensors for prediction in systems exhibiting multiple scales of dynamics. Finally, reconstruction accuracy from pivot sensors is shown to be competitive with sensors obtained using traditional computationally prohibitive optimization methods.

  6. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    PubMed

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  7. Soluble Megalin is Reduced in Cerebrospinal Fluid Samples of Alzheimer's Disease Patients.

    PubMed

    Spuch, Carlos; Antequera, Desireé; Pascual, Consuelo; Abilleira, Soledad; Blanco, María; Moreno-Carretero, María José; Romero-López, Jesús; Ishida, Tetsuya; Molina, Jose Antonio; Villarejo, Alberto; Bermejo-Pareja, Felix; Carro, Eva

    2015-01-01

    Megalin or low-density lipoprotein receptor-related protein-2 is a member of the low-density lipoprotein receptor family, which has been linked to Alzheimer's disease (AD) by clearing brain amyloid β-peptide (Aβ) across the blood-cerebrospinal fluid barrier at the choroid plexus. Here, we found a soluble form of megalin secreted from choroid plexus epithelial cells. Soluble megalin levels were also localized in the human cerebrospinal fluid (CSF), being reduced in AD patients. We have also shown that soluble megalin binding to Aβ is decreased in the CSF of AD patients, suggesting that decreased sequestration of Aβ in the CSF could be associated with defective clearance of Aβ and an increase of brain Aβ levels. Thus, therapies, which increase megalin expression, at the choroid plexus and/or enhance circulating soluble megalin hold potential to control brain Aβ-related pathologies in AD.

  8. Selenium speciation in paired serum and cerebrospinal fluid samples of sheep.

    PubMed

    Humann-Ziehank, Esther; Ganter, Martin; Michalke, Bernhard

    2016-01-01

    This study was performed to characterise selenium (Se) and Se species in cerebrospinal fluid (CSF) of sheep and its relation to the respective Se concentrations in serum. Paired samples from 10 adult sheep were used for the study. Five sheep were fed a diet with a marginal Se concentration of <0.05mg Se/kg diet dry weight (dw, Se(-)), and five animals were fed the same diet supplemented with sodium selenite revealing a concentration of 0.2mg Se/kg diet dw (Se(+)). The feeding strategy was conducted for two years; The results on metabolic effects were published previously. At the end of the feeding period, paired samples of serum and CSF were collected and analysed using ion exchange chromatography inductively coupled plasma-dynamic reaction cell-mass spectrometry (IEC-ICP-DRC-MS) technique for total Se concentration and concentrations of Se species. Albumin concentrations were analysed additionally. The feeding strategy caused significant differences (p<0.01) in serum Se concentrations with 33.1±5.11μg Se/l in the Se(-) group and 96.5±18.3μg Se/l in the Se(+) group, respectively. The corresponding total Se concentrations in CSF were 4.38±1.02μg Se/l and 6.13±1.64μg Se/l in the Se(-) and the Se(+) group, respectively, missing statistical significance (p=0.077). IEC-ICP-DRC-MS technique was able to differentiate the Se species selenoprotein P-bound Se (SePP), selenomethionine, glutathione peroxidase-bound Se (Se-GPx), selenocystine, thioredoxin reductase-bound Se, ovine serum albumin-bound Se (Se-OSA), SeIV and SeVI in ovine serum and CSF. Quantitatively, SePP is the main selenoprotein in ovine serum followed by Se-GPx. The CSF/blood ratio of albumin (QAlbumin) reflected a physiological function of the blood-CSF barrier in all sheep. QSe-species were higher than QAlbumin both feeding groups, supporting the hypothesis of local production of Se species in the brain. Significant positive regression lines for CSF vs. serum were found for albumin and Se-OSA only

  9. CTP (Cochlin-tomoprotein) detection in the profuse fluid leakage (gusher) from cochleostomy.

    PubMed

    Ikezono, Tetsuo; Sugizaki, Kazuki; Shindo, Susumu; Sekiguchi, Satomi; Pawankar, Ruby; Baba, Shunkichi; Yagi, Toshiaki

    2010-08-01

    By testing 125 samples, we confirmed that Cochlin-tomoprotein (CTP) is present in the perilymph, not in cerebrospinal fluid (CSF). Perilymph and CSF exist in two distinct compartments, even in the case of a malformed inner ear with a bony defect in the lamina cribrosa, as described here. Cochleostomy might have suddenly decreased the perilymph pressure, allowing the influx of CSF into the inner ear resulting in profuse fluid leakage, first perilymph then CSF. The first purpose of this study was to further confirm the specificity of the perilymph-specific protein CTP that we reported recently. Secondly, we assessed the nature of the fluid leakage from the cochleostomy using the CTP detection test. A standardized CTP detection test was performed on 65 perilymph and 60 CSF samples. Samples of profuse fluid leakage collected from cochleostomy during cochlear implantation surgery of one patient with branchio-oto-renal (BOR) syndrome were also tested by the CTP detection test. CTP was detected in 60 of 65 perilymph samples but not in any of the CSF samples. The leaked fluid was shown to contain CTP, i.e. perilymph, at the outset, and then the CTP detection signals gradually disappeared as time elapsed.

  10. Monitoring Fluid Flow in Fractured Carbonate Rocks Using Seismic Measurements

    NASA Astrophysics Data System (ADS)

    Li, W.; Pyrak-Nolte, L. J.

    2008-12-01

    The physical properties of carbonate rock are strongly influenced by the rock fabric which depends on the depositional environment, diagenetic and tectonic processes. The most common form of heterogeneity is layering caused by a variation in porosity among layers and within layers. The variation in porosity among layers leads to anisotropic behavior in the hydraulic, mechanical and seismic properties of carbonate rocks. We present the results of a laboratory study to examine the effect of fabric-controlled layering on fluid flow and seismic wave propagation through intact and fractured carbonate rock. Experiments were performed on cubic samples of Austin Chalk Cordova Cream. Samples AC1, AC5 and AC6 are cubic samples that measure 100 mm on edge. The samples were sealed and contained three inlet and three outlet ports for fluid invasion experiments. Two orthogonal seismic arrays were used to record both compressional and shear wave transmission through intact and fractured samples. The arrays used piezoelectric contact transducers with a central frequency 1.0 MHz. Between the two arrays, sixteen sources and sixteen receivers were used. Seismic measurements were made on the samples as a function of stress and during fluid saturation. The location of the invading fluid front as a function of time was monitored by using the peak-to-peak amplitude of the transmitted signals. The front was assumed to be between a source-receiver pair when the signal amplitude decreased by 50% over the initial value. The hydraulic gradient was parallel and perpendicular to the layers for AC5 and AC6, respectively. Sample AC1 was fractured and flow ports were established on the edges of the fracture plane. The weakly directed fabric controlled the rate at which fluid flowed through the samples. From the seismic data on AC6, the fluid first spread vertically along a layer before flowing across the layers. For AC6, it took the fluid two and half hours to flow between the inlet and the outlet

  11. Hyperacid volcano-hydrothermal fluids from Copahue volcano, Argentina: Analogs for "subduction zone fluids"?

    NASA Astrophysics Data System (ADS)

    Varekamp, J. C.

    2007-12-01

    Hyperacid concentrated Chlorine-Sulfate brines occur in many young arc volcanoes, with pH values <1, high concentrations of volcanogenic elements (S, Cl, F, As, B) and the main rock forming elements (Ca, Al, Mg, K, Na, P). Sulfur isotope data and Silica thermometry from such fluids sampled over a ten year period from the Copahue volcanic system (Argentina) suggest reservoir temperatures of 175-300 oC, whereas the surface fluids do not exceed local boiling temperatures. These fluids are generated at much lower P-T conditions than fluids associated with a dehydrating subducted sediment complex below arc volcanoes, but their fundamental chemical compositions may have similarities. Incompatible trace element, major element concentrations and Pb isotope compositions of the fluids were used to determine the most likely rock protoliths for these fluids. Mean rock- normalized trace element diagrams then indicate which elements are quantitatively extracted from the rocks and which are left behind or precipitated in secondary phases. Most LILE show flat rock-normalized patterns, indicating close to congruent dissolution, whereas Ta-Nb-Ti show strong depletions in the rock-normalized diagrams. These HFSE are either left behind in the altered rock protolith or were precipitated along the way up. The behavior of U and Th is almost identical, suggesting that in these low pH fluids with abundant ligands Th is just as easily transported as U, which is not the case in more dilute, neutral fluids. Most analyzed fluids have steeper LREE patterns than the rocks and have negative Eu anomalies similar to the rocks. Fluids that interacted with newly intruded magma e.g., during the 2000 eruption, have much less pronounced Eu anomalies, which was most likely caused by the preferential dissolution of plagioclase when newly intruded magma interacted with the acid fluids. The fluids show a strong positive correlation between Y and Cd (similar to MORB basalts, Yi et al., JGR, 2000), suggesting

  12. Pathological Knee Joint Motion Analysis By High Speed Cinephotography

    NASA Astrophysics Data System (ADS)

    Baumann, Jurg U.

    1985-02-01

    The use of cinephotography for evaluation of disturbed knee joint function was compared in three groups of patients. While a sampling rate of 50 images per second was adequate for patients with neuromuscular disorders, a higher frequency of around 300 i.p.s. is necessary in osteoarthritis and ligamentous knee joint injuries, but the task of digitizing is prohibitive unless automated.

  13. Well purge and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.; Gustafson, Gregg S.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly with a packer, pump and exhaust, that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. The packer is positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  14. Well purge and sample apparatus and method

    DOEpatents

    Schalla, R.; Smith, R.M.; Hall, S.H.; Smart, J.E.; Gustafson, G.S.

    1995-10-24

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly with a packer, pump and exhaust, that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. The packer is positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion. 8 figs.

  15. Fluid overpressures and strength of the sedimentary upper crust

    NASA Astrophysics Data System (ADS)

    Suppe, John

    2014-12-01

    The classic crustal strength-depth profile based on rock mechanics predicts a brittle strength σ1 -σ3 = κ(ρbar gz -Pf) that increases linearly with depth as a consequence of [1] the intrinsic brittle pressure dependence κ plus [2] an assumption of hydrostatic pore-fluid pressure, Pf = ρwgz. Many deep borehole stress data agree with a critical state of failure of this form. In contrast, fluid pressures greater than hydrostatic ρbar gz >Pf >ρw gz are normally observed in clastic continental margins and shale-rich mountain belts. Therefore we explore the predicted shapes of strength-depth profiles using data from overpressured regions, especially those dominated by the widespread disequilibrium-compaction mechanism, in which fluid pressures are hydrostatic above the fluid-retention depth zFRD and overpressured below, increasing parallel to the lithostatic gradient ρbar gz . Both brittle crustal strength and frictional fault strength below the zFRD must be constant with depth because effective stress (ρbar gz -Pf) is constant, in contrast with the classic linearly increasing profile. Borehole stress and fluid-pressure measurements in several overpressured deforming continental margins agree with this constant-strength prediction, with the same pressure-dependence κ as the overlying hydrostatic strata. The role of zFRD in critical-taper wedge mechanics and jointing is illustrated. The constant-strength approximation is more appropriate for overpressured crust than classic linearly increasing models.

  16. Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

    NASA Technical Reports Server (NTRS)

    Miller, Jennifer R.; Birur, Gajanana; Bame, David; Mastropietro, A. J.; Bhandari, Pradeep; Lee, Darlene; Karlmann, Paul; Liu, Yuanming

    2013-01-01

    Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

  17. Lensless, ultra-wideband fiber optic rotary joint for biomedical applications.

    PubMed

    Kim, Wihan; Chen, Xi; Jo, Javier A; Applegate, Brian E

    2016-05-01

    The demands of optical fiber-based biomedical applications can, in many cases, outstrip the capabilities of lens-based commercially available fiber optic rotary joints. In some circumstances, it is necessary to use very broad spectral bandwidths (near UV to short-wave IR) and specialized optical fibers, such as double-clad fiber, and have the capacity to accommodate high rotational velocities. The broad spectrum, stretching down into the UV, presents two problems: (1) adequate chromatic correction in the lenses across the entire bandwidth and (2) strong UV absorption by the fluids used to lubricate the rotary joint. To accommodate these types of applications, we have developed an ultra-wideband lensless fiber optic rotary joint based on the principle that when two optical fibers are coaligned and placed in contact (or very close), the optical losses at the junction are very low. The advances demonstrated here enable excellent performance (<0.2  dB insertion loss), even down into the UV and spanning a wavelength range of at least 355-1360 nm with single-mode, multimode, and double-clad fibers. We also demonstrate excellent performance, ∼0.38  dB insertion loss, at rotational velocities up to 8800 rpm (146 Hz). To the best of our knowledge, this is the first demonstration of this type of rotary joint capable of such a wide bandwidth and high rotational velocities.

  18. Upper limb joint forces and moments during underwater cyclical movements.

    PubMed

    Lauer, Jessy; Rouard, Annie Hélène; Vilas-Boas, João Paulo

    2016-10-03

    Sound inverse dynamics modeling is lacking in aquatic locomotion research because of the difficulty in measuring hydrodynamic forces in dynamic conditions. Here we report the successful implementation and validation of an innovative methodology crossing new computational fluid dynamics and inverse dynamics techniques to quantify upper limb joint forces and moments while moving in water. Upper limb kinematics of seven male swimmers sculling while ballasted with 4kg was recorded through underwater motion capture. Together with body scans, segment inertial properties, and hydrodynamic resistances computed from a unique dynamic mesh algorithm capable to handle large body deformations, these data were fed into an inverse dynamics model to solve for joint kinetics. Simulation validity was assessed by comparing the impulse produced by the arms, calculated by integrating vertical forces over a stroke period, to the net theoretical impulse of buoyancy and ballast forces. A resulting gap of 1.2±3.5% provided confidence in the results. Upper limb joint load was within 5% of swimmer׳s body weight, which tends to supports the use of low-load aquatic exercises to reduce joint stress. We expect this significant methodological improvement to pave the way towards deeper insights into the mechanics of aquatic movement and the establishment of practice guidelines in rehabilitation, fitness or swimming performance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Joint inversion of NMR and SIP data to estimate pore size distribution of geomaterials

    NASA Astrophysics Data System (ADS)

    Niu, Qifei; Zhang, Chi

    2018-03-01

    There are growing interests in using geophysical tools to characterize the microstructure of geomaterials because of the non-invasive nature and the applicability in field. In these applications, multiple types of geophysical data sets are usually processed separately, which may be inadequate to constrain the key feature of target variables. Therefore, simultaneous processing of multiple data sets could potentially improve the resolution. In this study, we propose a method to estimate pore size distribution by joint inversion of nuclear magnetic resonance (NMR) T2 relaxation and spectral induced polarization (SIP) spectra. The petrophysical relation between NMR T2 relaxation time and SIP relaxation time is incorporated in a nonlinear least squares problem formulation, which is solved using Gauss-Newton method. The joint inversion scheme is applied to a synthetic sample and a Berea sandstone sample. The jointly estimated pore size distributions are very close to the true model and results from other experimental method. Even when the knowledge of the petrophysical models of the sample is incomplete, the joint inversion can still capture the main features of the pore size distribution of the samples, including the general shape and relative peak positions of the distribution curves. It is also found from the numerical example that the surface relaxivity of the sample could be extracted with the joint inversion of NMR and SIP data if the diffusion coefficient of the ions in the electrical double layer is known. Comparing to individual inversions, the joint inversion could improve the resolution of the estimated pore size distribution because of the addition of extra data sets. The proposed approach might constitute a first step towards a comprehensive joint inversion that can extract the full pore geometry information of a geomaterial from NMR and SIP data.

  20. 21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...