Sample records for joint iapr international

  1. 77 FR 39560 - International Joint Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... DEPARTMENT OF STATE [Public Notice 7945] International Joint Commission International Joint Commission Invites Public Comment on Upper Great Lakes Report The International Joint Commission (IJC) announced today that it is inviting public comment on the final report of its International Upper Great...

  2. Predicting the Functional Roles of Knee Joint Muscles from Internal Joint Moments.

    PubMed

    Flaxman, Teresa E; Alkjær, Tine; Simonsen, Erik B; Krogsgaard, Michael R; Benoit, Daniel L

    2017-03-01

    Knee muscles are commonly labeled as flexors or extensors and aptly stabilize the knee against sagittal plane loads. However, how these muscles stabilize the knee against adduction-abduction and rotational loads remains unclear. Our study sought 1) to classify muscle roles as they relate to joint stability by quantifying the relationship between individual muscle activation patterns and internal net joint moments in all three loading planes and 2) to determine whether these roles change with increasing force levels. A standing isometric force matching protocol required subjects to modulate ground reaction forces to elicit various combinations and magnitudes of sagittal, frontal, and transverse internal joint moments. Surface EMG measured activities of 10 lower limb muscles. Partial least squares regressions determined which internal moment(s) were significantly related to the activation of individual muscles. Rectus femoris and tensor fasciae latae were classified as moment actuators for knee extension and hip flexion. Hamstrings were classified as moment actuators for hip extension and knee flexion. Gastrocnemius and hamstring muscles were classified as specific joint stabilizers for knee rotation. Vastii were classified as general joint stabilizers because activation was independent of moment generation. Muscle roles did not change with increasing effort levels. Our findings indicate muscle activation is not dependent on anatomical orientation but perhaps on its role in maintaining knee joint stability in the frontal and transverse loading planes. This is useful for delineating the roles of biarticular knee joint muscles and could have implications in robotics, musculoskeletal modeling, sports sciences, and rehabilitation.

  3. Designing an International Joint Venture Negotiation Game.

    ERIC Educational Resources Information Center

    Kenkel, Phil; And Others

    1996-01-01

    Evaluates a simulation game that models management problems encountered in negotiating and managing international joint ventures. Designed to instruct executives of state-owned agribusinesses in Indonesia in abstract concepts such as partner rapport, transfer price conflicts, and marketing disagreements, its success suggests that simulation games…

  4. Functional disorders of the temporomandibular joints: Internal derangement of the temporomandibular joint.

    PubMed

    Chang, Chih-Ling; Wang, Ding-Han; Yang, Mu-Chen; Hsu, Wun-Eng; Hsu, Ming-Lun

    2018-04-01

    Temporomandibular joint (TMJ) is one of the most complex joints of the human body. Due to its unique movement, in terms of combination of rotation and translator movement, disc of the joint plays an important role to maintain its normal function. In order to sustain the normal function of the TMJ, disc must be kept in proper position as well as maintain normal shape in all circumstances. Once the disc is not any more in its normal position during function of the joint, disturbance of the joint can be occurred which will lead to subsequent distortion of the disc. Shape of the disc can be influenced by many factors i.e.: abnormal function or composition of the disc itself. Etiology of the internal derangement of the disc remains controversial. Multifactorial theory has been postulated in most of previous manuscripts. Disc is composed of mainly extracellular matrix. Abnormal proportion of collagen type I & III may also leads to joint hypermobility which may be also a predisposing factor of this disorder. Thus it can be recognized as local manifestation of a systemic disorder. Different treatment modalities with from conservative treatment to surgical intervention distinct success rate have been reported. Recently treatment with extracellular matrix injection becomes more and more popular to strengthen the joint itself. Since multifactorial in character, the best solution of the treatment modalities should be aimed to resolve possible etiology from different aspects. Team work may be indication to reach satisfied results. Copyright © 2018. Published by Elsevier Taiwan.

  5. Strategies of Supporting Chinese Students in an International Joint Degree Program

    ERIC Educational Resources Information Center

    Arshakian, Arakssi; Wang, Vivian

    2017-01-01

    The international joint degree program is one of the recent ways of international collaborations in Higher Education. Those programs involve intensive academic collaborations as well as institutional alliance.?Such programs could provide a supportive environment for international students through international partnerships. The article provides a…

  6. The effects of Navy ship ladder descent on the knee internal joint reaction forces

    NASA Astrophysics Data System (ADS)

    Coulter, Jonathan D.; Weinhandl, Joshua T.; Bawab, Sebastian Y.; Ringleb, Stacie I.

    2017-02-01

    Military populations may be at risk for developing knee osteoarthritis and other knee problems when descending a Navy ship ladder, which differs from traditional stairs due to non-overlapping treads, a larger rise and a steeper inclination angle. The purpose of this study was to develop a forward dynamic model of the descent of a Navy ship ladder to determine how this motion affects the internal knee reaction forces and how altering the hamstring/quadriceps ratio affects the internal joint reaction forces in the knee. Kinematic and kinetic data were collected from three male sailors descending a replica of a Navy ship ladder and were used as input into a model constructed in OpenSim. The peak resultant joint reaction force was 6.6 × BW, which was greater than values reported in the literature in traditional stairs. Peak compressive and anterior joint reaction forces, 4.05 × BW and 5.46 × BW, respectively, were greater than reported values for a squat, a motion similar to descending a ship ladder. The average peak vertical and anterior internal joint reaction force at the knee were 4.05 × BW and 5.46 × BW, respectively. The resultant joint reaction forces calculated from the ladder descent were greater than stair descent and squatting. Little effects were found in the joint reaction forces after adjusting the quadriceps to hamstring muscle strength ratios, possibly because these ratios might change the distribution of the contact forces across the joint, not the resultant forces.

  7. Towards an Analytical Framework for Understanding the Development of a Quality Assurance System in an International Joint Programme

    ERIC Educational Resources Information Center

    Zheng, Gaoming; Cai, Yuzhuo; Ma, Shaozhuang

    2017-01-01

    This paper intends to construct an analytical framework for understanding quality assurance in international joint programmes and to test it in a case analysis of a European--Chinese joint doctoral degree programme. The development of a quality assurance system for an international joint programme is understood as an institutionalization process…

  8. Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

    NASA Technical Reports Server (NTRS)

    McWhorter, Bruce B.; Bolton, Doug E.; Hicken, Steve V.; Allred, Larry D.; Cook, Dave J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) uses an internal insulation J-joint design for the mated insulation interface between two assembled RSRM segments. In this assembled (mated) segment configuration, this J-joint design serves as a thermal barrier to prevent hot gases from affecting the case field joint metal surfaces and O-rings. A pressure sensitive adhesive (PSA) provides some adhesion between the two mated insulation surfaces. In 1995, after extensive testing, a new ODC-free PSA (free of ozone depleting chemicals) was selected for flight on RSRM-55 (STS-78). Post-flight inspection revealed that the J-joint, equipped with the new ODC-free PSA, did not perform well. Hot gas seeped inside the J-joint interface. Although not a flight safety threat, the J-joint hot gas intrusion on RSRM-55 was a mystery to the investigators since the PSA had previously worked well on a full-scale static test. A team was assembled to study the J-joint and PSA further. All J-joint design parameters, measured data, and historical performance data were re-reviewed and evaluated by subscale testing and analysis. Although both the ODC-free and old PSA were weakened by humidity, the ODC-free PSA strength was lower to start with. Another RSRM full-scale static test was conducted in 1998 and intentionally duplicated the gas intrusion. This test, along with many concurring tests, showed that if a J-joint was 1) mated with the new ODC-free PSA, 2) exposed to a history of high humidity (Kennedy Space Center levels), and 3) also a joint which experienced significant but normal joint motion (J-joint deformation resulting from motor pressurization dynamics) then that J-joint would open (allow gas intrusion) during motor operation. When all of the data from the analyses, subscale tests, and full-scale tests were considered together, a theory emerged. Most of the joint motion on the RSRM occurs early in motor operation at which point the J-joints are pulled into tension. If the new

  9. Implementing a Successful Faculty, Data Driven Model for Program Review.

    ERIC Educational Resources Information Center

    Beal, Suzanne; Davis, Shirley

    Frederick Community College (Maryland) utilizes both the Instructional Accountability Program Review (IAPR) and the Career Program Review (CPR) to assess program outcomes and determine progress in meeting goals and objectives. The IAPR is a comprehensive review procedure conducted by faculty and associate deans to evaluate all transfer, career,…

  10. Temporomandibular joint arthrocentesis for internal derangement with disc displacement without reduction.

    PubMed

    Bhargava, Darpan; Jain, Megha; Deshpande, Ashwini; Singh, Ajita; Jaiswal, Jagdish

    2015-06-01

    Temporomandibular joint (TMJ) disc derangement is defined as a malpositioning of the articular disc relative to the condyle and eminence. Arthrocentesis of the TMJ is a minimally invasive chair side procedure for the patients with TMJ internal derangement. This case report presents convincing results to keep arthrocentesis as an imperative procedure to relieve such patients of their acute symptoms. TMJ dynamics has also been discussed for an in-depth understanding of the pathology in cases with internal derangement.

  11. Internally supported flexible duct joint. [device for conducting fluids in high pressure systems

    NASA Technical Reports Server (NTRS)

    Kuhn, R. F., Jr. (Inventor)

    1975-01-01

    An internally supported, flexible duct joint for use in conducting fluids under relatively high pressures in systems where relatively large deflection angles must be accommodated is presented. The joint includes a flexible tubular bellows and an elongated base disposed within the bellows. The base is connected through radiating struts to the bellows near mid-portion and to each of the opposite end portions of the bellows through a pivotal connecting body. A motion-controlling linkage is provided for linking the connecting bodies, whereby angular displacement of the joint is controlled and uniformity in the instantaneous bend radius of the duct is achieved as deflection is imposed.

  12. Joint International Physics Summer School: Optics

    NASA Astrophysics Data System (ADS)

    Bondani, Maria; Allevi, Alessia; Soubusta, Jan; Haderka, Ondřej

    2015-10-01

    We report on the organization and realization of the Joint International Physics Summer School - Optics" devoted to High-School students. The idea of the School is to teach Physics through high-level experimental activities, suitably supported by introductory lectures and complemented by data analysis. The School is also open to the participation of a number of teachers, as an opportunity of refreshing their knowledge and increasing their experimental skills. Students and teachers are directly involved in the experimental activities. The aim of the activity is to stimulate students curiosity and interest and help them decide whether a future job career in Science could be suited for them. The School is organized in two weeks: the first in June-July in Como (Italy) at the Department of Science and High Technology and the second at the end of August in Olomouc (Czech Republic) at the Joint Laboratory of Optics. Two editions of the Summer School took place in 2013 and 2014 (overall 40 students and 3 teachers from Italy, 9 students from Czech Republic) and the third one will be in 2015. The first week of the School is devoted to introductory lectures (theoretical and experimental) to consolidate students' and teachers' knowledge of basic optics. The second week is devoted to several advanced experiments in linear, nonlinear, classical and quantum optics, performed in research laboratories. During the last day of the School, students are required to give a presentation of the results obtained during the experimental sessions.

  13. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for

  14. The International Space Station Solar Alpha Rotary Joint Anomaly Investigation

    NASA Technical Reports Server (NTRS)

    Harik, Elliot P.; McFatter, Justin; Sweeney, Daniel J.; Enriquez, Carlos F.; Taylor, Deneen M.; McCann, David S.

    2010-01-01

    The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high drive motor current draw. Increased structural vibrations near the joint were also observed. Subsequent inspections via Extravehicular Activity (EVA) discovered that the nitrided case-hardened steel bearing race on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A farreaching investigation of the anomaly was undertaken. The investigation included metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The results of the investigation showed that the anomaly had most probably been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors. To mitigate the impact of the damage, astronauts cleaned and lubricated the race ring surface with grease. This corrective action led to significantly improved performance of the mechanism both in terms of drive motor current and induced structural vibration.

  15. The International Space Station Solar Alpha Rotary Joint Anomaly Investigation

    NASA Technical Reports Server (NTRS)

    Harik, Elliot P.; McFatter, Justin; Sweeney, Daniel J.; Enriquez, Carlos F.; Taylor, Deneen M.; McCann, David S.

    2010-01-01

    The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high drive motor current draw. Increased structural vibrations near the joint were also observed. Subsequent inspections via Extravehicular Activity (EVA) discovered that the nitrided case hardened steel bearing race on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A far-reaching investigation of the anomaly was undertaken. The investigation included metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The results of the investigation showed that anomaly had most probably been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors. To mitigate the impact of the damage astronauts cleaned and lubricated the race ring surface with grease. This corrective action led to significantly improved performance of the mechanism both in terms of drive motor current and induced structural vibration.

  16. Applying the Joint Committee's 1994 Standards in International Contexts: A Case Study of Education Evaluations in Bangladesh

    ERIC Educational Resources Information Center

    Chatterji, Madhabi

    2005-01-01

    This case study examines the applicability of 1994 standards, offered by the Joint Committee on Standards for Educational Evaluation, to evaluations conducted in international contexts. The work is undertaken in response to an open invitation from the Joint Committee in its 1994 publication. The article addresses two purposes. First, it asks…

  17. Effects of Lateral and Medial Wedged Insoles on Knee and Ankle Internal Joint Moments During Walking in Healthy Men.

    PubMed

    Fukuchi, Claudiane A; Lewinson, Ryan T; Worobets, Jay T; Stefanyshyn, Darren J

    2016-11-01

    Wedged insoles have been used to treat knee pathologies and to prevent injuries. Although they have received much attention for the study of knee injury, the effects of wedges on ankle joint biomechanics are not well understood. This study sought to evaluate the immediate effects of lateral and medial wedges on knee and ankle internal joint loading and center of pressure (CoP) in men during walking. Twenty-one healthy men walked at 1.4 m/sec in five footwear conditions: neutral, 6° (LW6) and 9° (LW9) lateral wedges, and 6° (MW6) and 9° (MW9) medial wedges. Peak internal knee abduction moments and angular impulses, internal ankle inversion moments and angular impulses, and mediolateral CoP were analyzed. Analysis of variance with post hoc analysis and Pearson correlations were performed to detect differences between conditions. No differences in internal knee joint loading were found between neutral and any of the wedge conditions. However, as the wedge angle increased from medial to lateral, the internal ankle inversion moment (LW6: P = .020; LW9: P < .001; MW6: P = .046; MW9: P < .001) and angular impulse (LW9: P = .012) increased, and the CoP shifted laterally (LW9: P < .001) and medially (MW9: P < .001) compared with the neutral condition. Neither lateral nor medial wedges were effective in altering internal knee joint loading during walking. However, the greater internal ankle inversion moment and angular impulse observed with lateral wedges could lead to a higher risk of ankle injury. Thus, caution should be taken when lateral wedges need to be prescribed.

  18. Student perspectives on the development and evaluation of a joint international education to promote employability in Europe.

    PubMed

    Craig, Claire; Piškur, Barbara

    2012-01-01

    This article presents a student evaluation of a joint international education developed as part of a European project which sought to equip health care practitioners with the skills to support employability of individuals furthest removed from the labour market, disadvantaged on account of age, gender, migration or ethnicity. Thirty eight students out of the forty one students that participated in the pilot of four modules (NL, UK, SE, DE) returned completed digital questionnaires (92.6% response rate). The study is descriptive by nature. A questionnaire was used to collect the data from students. Additionally students attending the module in the UK also took part in a series of qualitative interviews which sought to explore their experiences in more detail. These were recorded, transcribed and analyzed. Students reported that joint education facilitates competence development. The competencies they identified (Information Communications Technology) were recognised as being key to enhancing employability of disadvantaged groups. The joint international education exemplified by EEE4all offers one model of how to build a responsive international curriculum to ensure that the workforce of the future is well placed to meet the needs of this changing world.

  19. Association of bone marrow edema with temporomandibular joint (TMJ) osteoarthritis and internal derangements.

    PubMed

    Wahaj, Aiyesha; Hafeez, Kashif; Zafar, Muhammad Sohail

    2017-01-01

    This study reviewed the dental literature in order to determine the association of bone marrow edema with osteoarthritis and temporomandibular joint (TMJ) internal derangement disorders. A literature search was performed using electronic databases PubMed/Medline (National Library of Medicine, Bethesda, Maryland) and Cochrane for articles published during the last 15 years (January 2000-December 2014). A predetermined inclusion and exclusion criteria were used for filtering the scientific papers. Research articles fulfilling the basic inclusion criteria were included in the review. The reviewed studies showed that bone marrow edema is found in painful joints with osteoarthritis in a majority of cases. A few cases with no pain or significant degenerative changes are reported to have a bone marrow edema pattern as well. Bone marrow edema, increased fluid level, and pain are associated with osteoarthritis in the majority of patients reporting TMJ arthritis. Degenerative and disc displacement conditions are multifactorial and require further investigations. Magnetic resonance imaging can be employed to detect bone marrow edema even in the absence of pain and clinical symptoms in the patients of internal derangements.

  20. The value of arthrography in the decision-making process regarding surgery for internal derangement of the temporomandibular joint.

    PubMed

    Nitzan, D W; Dolwick, F M; Marmary, Y

    1991-04-01

    In this study, the clinical and arthrographic findings from 43 internally deranged temporomandibular joints (TMJs) were compared with the intra-surgical observations. In 40 of 43 joints, arthrography did not provide any additional information useful for diagnosis or treatment. In six joints, the problem was misdiagnosed. Only in three joints did arthrography demonstrate the existence of perforation in the posterior attachment that had not been suspected during the clinical examination. Because of the doubtful importance of arthrographic information for the decision-making process, it is suggested that the method be applied only in cases in which clinical examination and plain radiographs have failed to uncover the signs and symptoms indicative of a TMJ disorder.

  1. Reliability Modeling Methodology for Independent Approaches on Parallel Runways Safety Analysis

    NASA Technical Reports Server (NTRS)

    Babcock, P.; Schor, A.; Rosch, G.

    1998-01-01

    This document is an adjunct to the final report An Integrated Safety Analysis Methodology for Emerging Air Transport Technologies. That report presents the results of our analysis of the problem of simultaneous but independent, approaches of two aircraft on parallel runways (independent approaches on parallel runways, or IAPR). This introductory chapter presents a brief overview and perspective of approaches and methodologies for performing safety analyses for complex systems. Ensuing chapter provide the technical details that underlie the approach that we have taken in performing the safety analysis for the IAPR concept.

  2. [Hyaluronate sodium treatment for internal derangement of temporomandibular joint: a systematic review based on randomized controlled trials].

    PubMed

    Li, Chunjie; Zhang, Yifan; Jia, Yuanyuan; Lü, Jun; Li, Longjiang; Shi, Zong-Dao

    2011-10-01

    To assess the efficacy and safety of hyaluronate sodium (HS) for internal derangement of temporomandibular joint by means of systematic review on relevant randomized controlled trials. After identifing the study question of the efficacy and safety of HS for internal derangement of temporomandibular joint, Medline, Cochrane Controlled Trials Register, EMBASE, OPEN SIGLE and CBM were searched electronically till October 3rd 2010. Hand-searching covering 19 dental journals in Chinese were also performed. Risk of bias assessment, with Cochrane Collaboration's tool, and data extraction of included studies were conducted by two reviewers in duplicate. Meta analysis was done with Revman 5.0.23 and the quality of evidence was evaluated by GRADE. 10 randomized controlled trials met the eligibility criteria and were included. All these studies had unclear risk of bias. When compared with negative control, HS showed a significant advantage on maximal mouth opening in short and long-term (P < 0.05), and clinical overall assessment in short-term (P < 0.05), but its effect on pain control and long-term effect on clinical overall assessment had no extra benefit (P > 0.05). Additionally, when compared with glucocorticoids, the participants who received HS injection would get a better clinical overall assessment in short-term and less adverse drug reactions (P < 0.05), but presented a similar temporomandibular joint pain relief and maximal mouth opening (P > 0.05). To a certain extent, HS had good efficacy and better safety than controls when treating internal derangement of temporomandibular joint. However, as the quality of some included studies were limited, more randomized controlled trials are needed to reinforce the conclusion.

  3. The role of molecular pain biomarkers in temporomandibular joint internal derangement.

    PubMed

    Ernberg, M

    2017-06-01

    There is evidence that low-grade inflammation may be responsible for pain and development of degenerative changes in temporomandibular joint internal derangement. This article reviews the current knowledge of the molecular mechanisms behind TMJ internal derangements. A non-systematic search was carried out in PubMed, Embase and the Cochrane library for studies regarding pathophysiological mechanisms behind internal derangements focusing on pain-mediating inflammatory and cartilage-degrading molecules. Recent data suggest that release of cytokines may be the key event for pain and cartilage destruction in TMJ internal derangements. Cytokines promote the release of matrix metalloproteinases (MMPs), and due to hypoxia, vascular endothelial growth factor (VEGF) is released. This activates chondrocytes to produce MMPs and reduce their tissue inhibitors (TIMPs) as well as the recruitment of osteoclasts, ultimately leading to cartilage and bone resorption. Also, proteoglycans have an important role in this process. Several cytokines, MMPs, TIMPs and VEGF have been identified in higher concentrations in the TMJ synovial fluid of patients with painful internal derangements and shown to be associated with the degree of degeneration. Other molecules that show elevated levels include hyaluronic acid synthase, disintegrin and metalloproteinase with thrombospondin motifs (ADAMTs), aggrecan, fibromodulin, biglycan and lumican. Taken together, more or less pronounced inflammation of TMJ structures with release of cytokines, MMPs and other molecular markers that interact in a complex manner may be responsible for tissue degeneration in internal derangements. As internal derangements may be symptom-free, the degree of inflammation, but also other mechanisms, may be important for pain development. © 2017 John Wiley & Sons Ltd.

  4. Cold forging and chemical heat treatment of the casing of the internal joint for VAZ cars

    NASA Astrophysics Data System (ADS)

    Arzamastsev, V. A.; Sardaev, N. L.; Kochergin, A. S.

    1996-11-01

    The technological process of cold forging applied for the first time in the production of the casing of the internal joint with races is described. The process operations of cold forging and the annealing and carburizing regimes for this part me described.

  5. FRAX® International Task Force of the 2010 Joint International Society for Clinical Densitometry & International Osteoporosis Foundation Position Development Conference.

    PubMed

    Cauley, Jane A; El-Hajj Fuleihan, Ghada; Luckey, Marjorie M

    2011-01-01

    Osteoporosis is a serious worldwide epidemic. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors and femoral neck BMD and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. The International Society for Clinical Densitometry (ISCD) in conjunction with the International Osteoporosis Foundation (IOF) assembled an international panel of experts that ultimately developed joint Official Positions of the ISCD and IOF advising clinicians regarding FRAX® usage. As part of the process, the charge of the FRAX® International Task Force was to review and synthesize data regarding geographic and race/ethnic variability in hip fractures, non-hip osteoporotic fractures, and make recommendations about the use of FRAX® in ethnic groups and countries without a FRAX® calculator. This synthesis was presented to the expert panel and constitutes the data on which the subsequent Official Positions are predicated. A summary of the International Task Force composition and charge is presented here. Copyright © 2011 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  6. Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis.

    PubMed

    Wu, Tao; Ren, Xuejiao; Cui, Yunwei; Cheng, Xiaodong; Peng, Shuo; Hou, Zhiyong; Han, Yongtai

    2018-06-19

    To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.

  7. [Surgery of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws].

    PubMed

    Zhang, P; Dong, Q R; Wang, Z Y; Chen, B; Wan, J H; Wang, L

    2016-11-08

    Objective: To explore the manual operation skills of operative treatment of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws, and to study the clinical results. Method: From Jan 2009 to Dec 2014, the clinical data of 13 patients with ipsilateral Hawkins Ⅲ talus neck and ankle joint fractres via internal and lateral approaches with Herbert screws were retrospectively analyzed in our department.There were 10 males and 3 female, ranging in age from 20 to 60 years with an average age of 31.5 years.The fractures occurred on the right side in 9 patients and on the left side in 4 patients.Three cases had the complication of medial malleolar fracture.Ten cases had the complication of medial and lateral malleolar fracture. Totally 11 cases were made calcaneal skeletal traction, and all the were made CT with three-dimensional image reconstruction.Two cases were treated with emergency operation.Eleven cases were treated with selective operation.The operation time was 5 hours-10 days after injury. The functional results were evaluated by American Orthopaedic Foot and Ankle Society (AOFAS). Result: The average duration of follow-up was 22.6 months (range, 14-65 months). There was skin necrosis in one cases, no incision infection, malunion and nonunion of the fractures and loss of reduction. At final follow-up, AOFAS ankle score was 75.2 (range, 42 to 93), higher than preoperative 39.2 (range, 23 to 60), the difference was statistically significant ( P =0.023). The result was excellent in 4 cases, good in 5 cases, fair in 3 cases and 1 cases in poor, and the overall excellent or good rate was 69.2%. Avascular necrosis occurred in 3 cases (23.1%, 3/13). Traumatic arthritis was found in 5 cases (38.5%, 5/13), involved tibial astragaloid joint in 2 cases, involved subtalar joint in 1 case, involved tibial astragaloid joint and subtalar joint in 2 cases. Conclusion: The effect of surgical treatment for ipsilateral

  8. Evaluation of body posture in individuals with internal temporomandibular joint derangement.

    PubMed

    Munhoz, Wagner Cesar; Marques, Amélia Pasqual; de Siqueira, José Tadeu Tesseroli

    2005-10-01

    Temporomandibular dysfunctions (TMD) comprise a great number of disruptions that may affect the temporomandibular joint (TMJ), the masticatory muscles, or both. TMJ internal derangement is a specific type of TMD, of which the etiology and physiopathology are broadly unknown, but have been suggested to be linked to head, neck, and body posture factors. This study aimed at verifying possible relationships between body posture and TMJ internal derangements (TMJ-id), by comparing 30 subjects presenting typical TMJ-id signs to 20 healthy subjects. Subjects' clinical evaluations included anamnesis, stomatognatic system evaluation, and plotting analysis on body posture photographs. No statistically significant differences were found between the groups. Results do not support the assertion that body posture plays a role in causing or enhancing TMD; however, these results should be cautiously considered because of the small number of subjects evaluated and the many posture variables submitted to statistical procedures that lead to high standard deviations.

  9. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    PubMed

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  10. Pierre Auger Observatory and Telescope Array: Joint Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abu-Zayyad, T.; et al.

    2013-10-02

    Joint contributions of the Pierre Auger and Telescope Array Collaborations to the 33rd International Cosmic Ray Conference, Rio de Janeiro, Brazil, July 2013: cross-calibration of the fluorescence telescopes, large scale anisotropies and mass composition.

  11. Adaptive Shape Functions and Internal Mesh Adaptation for Modelling Progressive Failure in Adhesively Bonded Joints

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott; Gries, Thomas; Waas, Anthony M.; Pineda, Evan J.

    2014-01-01

    Enhanced finite elements are elements with an embedded analytical solution that can capture detailed local fields, enabling more efficient, mesh independent finite element analysis. The shape functions are determined based on the analytical model rather than prescribed. This method was applied to adhesively bonded joints to model joint behavior with one element through the thickness. This study demonstrates two methods of maintaining the fidelity of such elements during adhesive non-linearity and cracking without increasing the mesh needed for an accurate solution. The first method uses adaptive shape functions, where the shape functions are recalculated at each load step based on the softening of the adhesive. The second method is internal mesh adaption, where cracking of the adhesive within an element is captured by further discretizing the element internally to represent the partially cracked geometry. By keeping mesh adaptations within an element, a finer mesh can be used during the analysis without affecting the global finite element model mesh. Examples are shown which highlight when each method is most effective in reducing the number of elements needed to capture adhesive nonlinearity and cracking. These methods are validated against analogous finite element models utilizing cohesive zone elements.

  12. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female anorectal dysfunction.

    PubMed

    Sultan, Abdul H; Monga, Ash; Lee, Joseph; Emmanuel, Anton; Norton, Christine; Santoro, Giulio; Hull, Tracy; Berghmans, Bary; Brody, Stuart; Haylen, Bernard T

    2017-01-01

    The terminology for anorectal dysfunction in women has long been in need of a specific clinically-based Consensus Report. This Report combines the input of members of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted on Committee by experts in their fields to form a Joint IUGA/ICS Working Group on Female Anorectal Terminology. Appropriate core clinical categories and sub classifications were developed to give an alphanumeric coding to each definition. An extensive process of twenty rounds of internal and external review was developed to exhaustively examine each definition, with decision-making by collective opinion (consensus). A Terminology Report for anorectal dysfunction, encompassing over 130 separate definitions, has been developed. It is clinically based with the most common diagnoses defined. Clarity and user-friendliness have been key aims to make it interpretable by practitioners and trainees in all the different specialty groups involved in female pelvic floor dysfunction. Female-specific anorectal investigations and imaging (ultrasound, radiology and MRI) has been included whilst appropriate figures have been included to supplement and help clarify the text. Interval review (5-10 years) is anticipated to keep the document updated and as widely acceptable as possible. A consensus-based Terminology Report for female anorectal dysfunction terminology has been produced aimed at being a significant aid to clinical practice and a stimulus for research. Neurourol. Urodynam. 36:10-34, 2017. © 2016 Wiley Periodicals, Inc., and The International Urogynecological Association. © 2016 Wiley Periodicals, Inc., and The International Urogynecological Association.

  13. PREFACE: Joint Varenna-Lausanne International Workshop 2014

    NASA Astrophysics Data System (ADS)

    2014-11-01

    The 2014 joint Varenna-Lausanne international workshop on the theory of fusion plasmas was once more a great meeting. The programme covers a wide variety of topics, namely turbulence, MHD, edge physics and RF wave heating. The broad spectrum of skills involved in this meeting, from fundamental to applied physics, is striking. The works published in this special issue combine mathematics, numerics and physics at various levels - confirming the increasing integration of expertise in our community. As an incentive to read this cluster, let us mention a few outstanding results. Several papers address fundamental issues in turbulent transport, in particular the dynamics of structures. It is quite remarkable that this subject is now mature enough to propose signatures that can be tested by measurements. Linear and non linear MHD was also at the forefront. Several works illustrate the increasing level of realistic description of a fusion device, in particular by implementing complicated wall geometries. Moreover some noticeable progress has been made in the understanding of reconnection processes in collisionless regimes. The activity on radio-frequency heating and current drive is well represented, driven by the future operation of W7-X, ITER, and DEMO on a longer time scale. Finally the development of innovative numerical techniques, an old tradition of the conference, has driven several nice articles. The programme committee is traditionally keen in promoting young scientists. A number of senior scientists also attend the meeting on a regular basis, so that the attendance was nicely balanced. We believe that these efforts have been particularly fruitful this year. The number of young (and less young) faces was particularly impressive and this special issue illustrates this feature. The success of the 2014 edition brings evidence that the joint Varenna-Lausanne is the right place for presenting th The quality and size of the scientific production is illustrated by the

  14. Examining Functioning and Contextual Factors in Individuals with Joint Contractures from the Health Professional Perspective Using the ICF: An International Internet-Based Qualitative Expert Survey.

    PubMed

    Fischer, Uli; Müller, Martin; Strobl, Ralf; Bartoszek, Gabriele; Meyer, Gabriele; Grill, Eva

    2016-01-01

    The aim of this study was to identify disease-related aspects of functioning and disability in people with joint contractures from a health professionals' perspective and to describe the findings, using categories of the International Classification of Functioning, Disability, and Health (ICF). An Internet-based expert survey. We asked international health professionals for typical problems in functioning and important contextual factors of individuals with joint contractures using an Internet-based open-ended questionnaire. All answers were linked to the ICF according to established rules. Absolute and relative frequencies of the linked ICF categories were reported. Eighty experts named 1785 meaning units which could be linked to 256 ICF categories. Among the categories, 24.2% belonged to the component Body Functions, 20.7% to Body Structures, 36.3% to Activities and Participation, and 18.8% to Environmental Factors. Health professionals addressed a large variety of functional problems and multifaceted aspects due to the symptom joint contractures. International health professionals reported a large variety of aspects of functioning and health, which are related to joint contractures. © 2014 Association of Rehabilitation Nurses.

  15. 26 CFR 1.6015-1 - Relief from joint and several liability on a joint return.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... they claim losses attributable to H's limited partnership interest in Partnership A. In January 2006... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Relief from joint and several liability on a... joint and several liability on a joint return. (a) In general. (1) An individual who qualifies and...

  16. The Cultural Context of Learning in International Joint Ventures.

    ERIC Educational Resources Information Center

    Liu, Shimin; Vince, Russ

    1999-01-01

    A study of Chinese-Western joint business ventures showed that cultural context and different modes of managing and organizing must be considered. Successful joint ventures involve a process of collective, two-way learning. (SK)

  17. Making an International Impact: A Joint International Astronomy Project

    ERIC Educational Resources Information Center

    Scott, Robert; Shen, Xinrong; Mulley, Ian

    2012-01-01

    Early in 2010, a group of year 11 students (age 15-16) studying GCSE (General Certificate of Secondary Education) Astronomy at The Radclyffe School, Oldham, in the UK, teamed up with a similar age group from Tianyi High School, Wuxi City, in China, to undertake a joint astronomy investigation. This article outlines the outcome of the first stage…

  18. 78 FR 40260 - International Joint Commission: Public Comment on a Proposal for Lake Ontario and St. Lawrence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... DEPARTMENT OF STATE [Public Notice 8369] International Joint Commission: Public Comment on a... inviting the public to comment on a proposal for managing the water levels and flows in Lake Ontario and.... Lawrence River. Since 1960, the IJC has managed the flow of water at the Moses- Saunders hydropower dam...

  19. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or its...

  20. In Vivo Talocrural Joint Contact Mechanics With Functional Ankle Instability.

    PubMed

    Kobayashi, Takumi; Suzuki, Eiichi; Yamazaki, Naohito; Suzukawa, Makoto; Akaike, Atsushi; Shimizu, Kuniaki; Gamada, Kazuyoshi

    2015-12-01

    Functional ankle instability (FAI) may involve abnormal kinematics and contact mechanics during ankle internal rotation. Understanding of these abnormalities is important to prevent secondary problems in patients with FAI. However, there are no in vivo studies that have investigated talocrural joint contact mechanics during weightbearing ankle internal rotation. The objective of this study to determine talocrural contact mechanics during weightbearing ankle internal rotation in patients with FAI. Twelve male subjects with unilateral FAI (age range, 18-26 years) were enrolled. Computed tomography and fluoroscopic imaging of both lower extremities were obtained during weightbearing passive ankle joint complex rotation. Three-dimensional bone models created from the computed tomographic images were matched to the fluoroscopic images to compute 6 degrees of freedom for talocrural joint kinematics. The closest contact area in the talocrural joint in ankle neutral rotation and maximum internal rotation during either dorsiflexion or plantar flexion was determined using geometric bone models and talocrural joint kinematics data. The closest contact area in the talus shifted anteromedially during ankle dorsiflexion-internal rotation, whereas it shifted posteromedially during ankle plantar flexion-internal rotation. The closest contact area in FAI joints was significantly more medial than that in healthy joints during maximum ankle internal rotation and was associated with excessive talocrural internal rotation or inversion. This study demonstrated abnormal talocrural kinematics and contact mechanics in FAI subjects. Such abnormal kinematics may contribute to abnormal contact mechanics and may increase cartilage stress in FAI joints. Therapeutic, Level IV: cross-sectional case-control study. © 2015 The Author(s).

  1. 78 FR 49242 - Relief From Joint and Several Liability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-13

    ... Relief From Joint and Several Liability AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice... joint and several tax liability under section 6015 of the Internal Revenue Code (Code) and relief from... are husband and wife to file a joint Federal income tax return. Married individuals who choose to file...

  2. FRAX(®) Clinical Task Force of the 2010 Joint International Society for Clinical Densitometry & International Osteoporosis Foundation Position Development Conference.

    PubMed

    McCloskey, Eugene V; Binkley, Neil

    2011-01-01

    The World Health Organization fracture risk assessment tool, FRAX(®), is an advance in clinical care that can assist in clinical decision-making. However, with increasing clinical utilization, numerous questions have arisen regarding how to best estimate fracture risk in an individual patient. Recognizing the need to assist clinicians in optimal use of FRAX(®), the International Osteoporosis Foundation (IOF) in conjunction with the International Society for Clinical Densitometry (ISCD) assembled an international panel of experts that ultimately developed joint Official Positions of the ISCD and IOF advising clinicians regarding FRAX(®) usage. As part of the process, the charge of the FRAX(®) Clinical Task Force was to review and synthesize data surrounding a number of recognized clinical risk factors including rheumatoid arthritis, smoking, alcohol, prior fracture, falls, bone turnover markers and glucocorticoid use. This synthesis was presented to the expert panel and constitutes the data on which the subsequent Official Positions are predicated. A summary of the Clinical Task Force composition and charge is presented here. Copyright © 2011. Published by Elsevier Inc.

  3. Phase 1 Program Joint Report

    NASA Technical Reports Server (NTRS)

    Nield, George C. (Editor); Vorobiev, Pavel Mikhailovich (Editor)

    1999-01-01

    This report consists of inputs from each of the Phase I Program Joint Working Groups. The Working Groups were tasked to describe the organizational structure and work processes that they used during the program, joint accomplishments, lessons learned, and applications to the International Space Station Program. This report is a top-level joint reference document that contains information of interest to both countries.

  4. Internal derangements of the temporomandibular joint: A review of the anatomy, diagnosis, and management

    PubMed Central

    Young, Andrew L.

    2015-01-01

    Internal derangements of the temporomandibular joint are conditions in which the articular disc has become displaced from its original position the condylar head. Relevant anatomic structures and their functional relationships are briefly discussed. The displacement of the disc can result in numerous presentations, with the most common being disc displacement with reduction (with or without intermittent locking), and disc displacement without reduction (with or without limited opening). These are described in this article according to the standardized Diagnostic Criteria for Temporomandibular Disorders, as well as the less common posterior disc displacement. Appropriate management usually ranges from patient education and monitoring to splints, physical therapy, and medications. In rare and select cases, surgery may be necessary. However, in for the majority of internal derangements, the prognosis is good, particularly with conservative care. PMID:26929478

  5. Internal derangements of the temporomandibular joint: A review of the anatomy, diagnosis, and management.

    PubMed

    Young, Andrew L

    2015-01-01

    Internal derangements of the temporomandibular joint are conditions in which the articular disc has become displaced from its original position the condylar head. Relevant anatomic structures and their functional relationships are briefly discussed. The displacement of the disc can result in numerous presentations, with the most common being disc displacement with reduction (with or without intermittent locking), and disc displacement without reduction (with or without limited opening). These are described in this article according to the standardized Diagnostic Criteria for Temporomandibular Disorders, as well as the less common posterior disc displacement. Appropriate management usually ranges from patient education and monitoring to splints, physical therapy, and medications. In rare and select cases, surgery may be necessary. However, in for the majority of internal derangements, the prognosis is good, particularly with conservative care.

  6. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female anorectal dysfunction.

    PubMed

    Sultan, Abdul H; Monga, Ash; Lee, Joseph; Emmanuel, Anton; Norton, Christine; Santoro, Giulio; Hull, Tracy; Berghmans, Bary; Brody, Stuart; Haylen, Bernard T

    2017-01-01

    The terminology for anorectal dysfunction in women has long been in need of a specific clinically-based Consensus Report. This Report combines the input of members of the Standardization and Terminology Committees of two International Organizations, the International Urogynecological Association (IUGA) and the International Continence Society (ICS), assisted on Committee by experts in their fields to form a Joint IUGA/ICS Working Group on Female Anorectal Terminology. Appropriate core clinical categories and sub classifications were developed to give an alphanumeric coding to each definition. An extensive process of twenty rounds of internal and external review was developed to exhaustively examine each definition, with decision-making by collective opinion (consensus). A Terminology Report for anorectal dysfunction, encompassing over 130 separate definitions, has been developed. It is clinically based with the most common diagnoses defined. Clarity and user-friendliness have been key aims to make it interpretable by practitioners and trainees in all the different specialty groups involved in female pelvic floor dysfunction. Female-specific anorectal investigations and imaging (ultrasound, radiology and MRI) has been included whilst appropriate figures have been included to supplement and help clarify the text. Interval review (5-10 years) is anticipated to keep the document updated and as widely acceptable as possible. A consensus-based Terminology Report for female anorectal dysfunction terminology has been produced aimed at being a significant aid to clinical practice and a stimulus for research.

  7. Comorbidity of internal derangement of the temporomandibular joint and silent dysfunction of the cervical spine.

    PubMed

    Stiesch-Scholz, M; Fink, M; Tschernitschek, H

    2003-04-01

    The aim of this evaluation was to examine correlations between internal derangement of the temporomandibular joint (TMJ) and cervical spine disorder (CSD). A prospective controlled clinical study was carried out. Thirty patients with signs and symptoms of internal derangement but without any subjective neck problems and 30 age- and gender-matched control subjects without signs and symptoms of internal derangement were examined. The investigation of the temporomandibular system was carried out using a 'Craniomandibular Index'. Afterwards an examiner-blinded manual medical investigation of the craniocervical system was performed. This included muscle palpation of the cervical spine and shoulder girdle as well as passive movement tests of the cervical spine, to detect restrictions in the range of movement as well as segmental intervertebral dysfunction. The internal derangement of the TMJ was significantly associated with 'silent' CSD (t-test, P < 0.05). Patients with raised muscle tenderness of the temporomandibular system exhibited significantly more often pain on pressure of the neck muscles than patients without muscle tenderness of the temporomandibular system (t-test, P < 0.05). As a result of the present study, for patients with internal derangement of the TMJ an additional examination of the craniocervical system should be recommended.

  8. Development Requirements for Spacesuit Elbow Joint

    NASA Technical Reports Server (NTRS)

    Peters, Benjamin

    2017-01-01

    Functional Requirements for spacesuit elbow joint:1) The system is a conformal, single-axis spacesuit pressurized joint that encloses the elbow joint of the suited user and uses a defined interface to connect to the suit systems on either side of the joint.2) The system shall be designed to bear the loads incurred from the internal pressure of the system, as well as the expected loads induced by the user while enabling the user move the joint through the required range of motion. The joint torque of the system experienced by the user shall remain at or below the required specification for the entire range of motion.3) The design shall be constructed, at a minimum, as a two-layer system. The internal, air-tight layer shall be referred to as the bladder, and the layer on the unpressurized side of the bladder shall be referred to as the restraint. The design of the system may include additional features or layers, such as axial webbing, to meet the overall requirements of the design.

  9. Radiographic evaluation of cervical spine of subjects with temporomandibular joint internal disorder.

    PubMed

    Munhoz, Wagner Cesar; Marques, Amélia Pasqual; Siqueira, José Tadeu Tesseroli de

    2004-01-01

    Although the etiopathophysiology of internal temporomandibular joint internal disorders (TMJ ID) is still unknown, it has been suggested that head and body posture could be related to its initial onset, development and perpetuation. The purpose of the present study was to observe the relationship between cervical spine X-ray abnormalities and TMJ ID. This investigation evaluated 30 subjects with internal TMJ disorder symptoms (test group) and 20 healthy subjects (control group). Subjects were submitted to clinical and radiographic evaluation. Clinical evaluation comprised anamnesis and stomatognathic system physical examination. Radiographic evaluation comprised analysis of lateral cervical spine X-rays by three physical therapists and tracing on the same images. The test group presented twice as much cervical spine hyperlordosis as the control group (20.7% versus 10.5%), but almost half of rectification prevalence (41.4 versus 79.0%, p = 0.03). After that, the test group was divided into three subgroups according to TMJ dysfunction severity, evaluated by Helkimo's index. These subgroups were not significantly different, but the subgroup with more severe TMD showed a tendency to cervical spine hyperlordosis prevalence. Results showed a tendency for subjects with more severe TMD to exhibit cervical spine hyperlordosis. Nevertheless, studies with a larger number of subjects suffering from severe TMD are encouraged in order to corroborate the present findings.

  10. Joint Commission

    MedlinePlus

    ... Progress, June 2016 issue, explores The Joint Commission’s internal Robust Process Improvement ® program. Read the ... cry for improving our services. It has provided a pulpit from which we structure quality and safety activities and get buy-in from ...

  11. Chewing movements altered in the presence of temporomandibular joint internal derangements.

    PubMed

    Radke, John C; Kull, Robert S; Sethi, Manminder S

    2014-07-01

    The objectives were to find specific factors that are mathematically distinct between the chewing timings, movement pattern shapes, variability, and movement velocities of: (1) normal asymptomatic subjects and (2) a group of subjects with verified temporomandibular joint (TMJ) internal derangements. Left- and right-sided chewing movement recordings of 28 subjects (34.5 ± 14.0 years) were randomly selected from a large database of patients exhibiting verified unilateral or bilateral TMJ internal derangements. The chewing movements of an age- and gender-matched control group of 20 asymptomatic subjects (32.5 ± 11.6 years, P>0.60) with verified normal TMJ function were also recorded. Means and standard deviations of the opening, closing, turning point, terminal chewing position, and velocity patterns were calculated. A two-tailed Student's t-test with unequal variances was used to compare the parameters between the two groups (alpha = 0.05). The dysfunctional group functioned significantly slower and with greater variability than the control group. The vertical dimension was consistently smaller in the dysfunctional group (P<0.00001). The terminal chewing position was significantly less precise in the dysfunctional group (vertical: P<0.002 and lateral: P<0.037). The maximum lateral width was significantly less (P<0.0071), and the peak and the average velocities were significantly lower (P<0.00001 for both) in the dysfunctional group. This group of dysfunctional subjects exhibited significantly slower, smaller, and more variable chewing patterns than the control group. The functional pattern of mastication appears to be significantly altered in the presence of an internal derangement of the TMJ.

  12. Vascular risk reduction during anterior surgical approach sacroiliac joint plating.

    PubMed

    Alla, Sreenivasa R; Roberts, Craig S; Ojike, Nwakile I

    2013-02-01

    Open reduction and internal fixation of sacroiliac (SI) joint is often performed through an anterior approach. However, there were no studies to our knowledge which described the "at risk area" for injury to the nutrient artery as it relates to open reduction and internal fixation of the SI joint. The purpose of this study was to determine the "at risk area" for the nutrient artery during anterior surgical approaches to the SI joint and to define the safe location of the plate for SI joint fixation. Six right and five left hemipelvises (three male and three female cadavers) were dissected with a mean age of 72 years (range, 51-90 years). Three bony landmarks including the pelvic brim, anterior SI joint line, and the anterior superior iliac spine (ASIS) were identified to quantify the measurements. Three different measurements were taken: from the nutrient foramen to the anterior SI joint line; from the nutrient foramen to the nearest point on the pelvic brim; from the nutrient foramen to ASIS using a flexible ruler with a 1mm base. The nutrient artery courses across the SI joint to enter into the nutrient foramen. Whilst exposing the internal surface of the SI joint, the nutrient foramen was identified at a mean distance of 88.1mm medial to ASIS, 20.1mm above the pelvic brim, and 20.1mm lateral to SI joint. The variability of the location of the nutrient foramen was identified and was located from 80mm to 95mm medial to the ASIS, 12mm to 25mm lateral to the SI joint, and 16mm to 30mm above the pelvic brim. Familiarity of the vasculature of the internal pelvis is of utmost importance for the surgeon when considering operative fixation of the anterior SI joint. We were able to identify the relation of the nutrient artery to the anatomic landmarks of the internal pelvis and to define the "at risk area" for the nutrient artery. We believe increased understanding of the anatomy of the nutrient artery will aid in the avoidance of vascular complications during internal

  13. The Zeitgeist of Challenging the Evidence. A Perspective on the International Consensus Meeting on Periprosthetic Joint Infection.

    PubMed

    Fayaz, Hangama C; Jupiter, Jesse B

    2017-01-01

    The economic burden of the treatment of periprosthetic joint infection (PJI) is high and the treatment of PJI has a high degree of international controversy. Several papers have declared the International Consensus Meeting on Periprosthetic Joint Infection (ICMPJI) to be the "flawless pledge of international academics" to overcome the challenges of musculoskeletal infections. The purpose of this paper is to highlight for the first time some essential insights into the key dilemmas that are associated with this international consensus process. The proceedings of the ICMPJI was reviewed, and the critical consensus agreements that were reached were communicated via e-mail to 48 leading orthopaedic surgeons, microbiologists and statisticians around the world. Of these, 30 responded, 8 did not, and 10 of respondents were not aware of the ICMPJI. A thorough review of the ICMPJI proceedings identified a clear need to resolve some of the dilemmas that we highlight in this paper. The Delphi procedure has been described as a survey technique that enables a group dynamic-based practice. Although there have been several published reports on this procedure, its scientific merit is still being debated. Several challenges and questions have been raised regarding the application of the Delphi technique, but there is no doubt that it is a vital approach for achieving consensus on subjects where none currently exists. Performing prospective clinical studies in this area is currently the best and only option to overcome this challenge. In the long term, this approach will not only incorporate the standard of clinical evidence but also adopt regional mores for treating infection, which include patient values, cultural differences and local financial resources.

  14. The Zeitgeist of Challenging the Evidence. A Perspective on the International Consensus Meeting on Periprosthetic Joint Infection

    PubMed Central

    Fayaz, Hangama C.; Jupiter, Jesse B.

    2017-01-01

    Background: The economic burden of the treatment of periprosthetic joint infection (PJI) is high and the treatment of PJI has a high degree of international controversy. Several papers have declared the International Consensus Meeting on Periprosthetic Joint Infection (ICMPJI) to be the “flawless pledge of international academics” to overcome the challenges of musculoskeletal infections. The purpose of this paper is to highlight for the first time some essential insights into the key dilemmas that are associated with this international consensus process. Methods: The proceedings of the ICMPJI was reviewed, and the critical consensus agreements that were reached were communicated via e-mail to 48 leading orthopaedic surgeons, microbiologists and statisticians around the world. Of these, 30 responded, 8 did not, and 10 of respondents were not aware of the ICMPJI. Results: A thorough review of the ICMPJI proceedings identified a clear need to resolve some of the dilemmas that we highlight in this paper. The Delphi procedure has been described as a survey technique that enables a group dynamic-based practice. Although there have been several published reports on this procedure, its scientific merit is still being debated. Several challenges and questions have been raised regarding the application of the Delphi technique, but there is no doubt that it is a vital approach for achieving consensus on subjects where none currently exists. Conclusion: Performing prospective clinical studies in this area is currently the best and only option to overcome this challenge. In the long term, this approach will not only incorporate the standard of clinical evidence but also adopt regional mores for treating infection, which include patient values, cultural differences and local financial resources. PMID:28271085

  15. 26 CFR 20.2040-1 - Joint interests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 14 2011-04-01 2010-04-01 true Joint interests. 20.2040-1 Section 20.2040-1... ESTATE TAX; ESTATES OF DECEDENTS DYING AFTER AUGUST 16, 1954 Gross Estate § 20.2040-1 Joint interests. (a... personal, and regardless of when the joint interests were created. Furthermore, it makes no difference that...

  16. Epilepsy and driving: an international perspective. Joint Commission on Drivers' Licensing of the International Bureau for Epilepsy and the International League Against Epilepsy.

    PubMed

    Fisher, R S; Parsonage, M; Beaussart, M; Bladin, P; Masland, R; Sonnen, A E; Rémillard, G

    1994-01-01

    Individuals with a history of seizures may be granted driving privileges if the risks of future seizure while driving are relatively low. Different nations have defined these risks in a wide variety of ways. Some countries, e.g., Japan, Greece, Brazil, India, and Russia, preclude driving after a single seizure. Other countries, such as Canada and the United States, allow driving < or = 3 months after certain types of seizures. A Joint Commission of the International Bureau for Epilepsy/International League Against Epilepsy has summarized regulations in several countries. From a consideration of medical literature and existing practices, a series of proposed guidelines for driving and epilepsy is recommended. In general, these guidelines suggest use of a seizure-free interval, generally 1-2 years but less in particular instances, to determine fitness to drive. Required physician reporting is discouraged, but physicians should report patients whom they believe pose a danger to themselves and to public safety. Individualized consideration should be given to special circumstances that may modify a general driving prohibition. Education and information programs are necessary for medical and regulatory authorities to develop a rational approach to driving and epilepsy worldwide.

  17. Effect of Joint Commission International Accreditation on the Nursing Work Environment in a Tertiary Medical Center.

    PubMed

    Kagan, Ilya; Farkash-Fink, Naomi; Fish, Miri

    2016-01-01

    How might a tertiary hospital's nursing staff respond to the huge improvement effort required for external accreditation if they are encouraged to lead the change process themselves? This article reports the results of a concurrent evaluation of the nursing work climate at ward level, before and after accreditation by the Joint Commission International. Physician-nurse relations improved; the involvement of social workers, dieticians, and physiotherapists increased; support services responded more quickly to requests; and management-line staff relations became closer.

  18. Influence of the implant-abutment connection design and diameter on the screw joint stability.

    PubMed

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo

    2014-04-01

    This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.

  19. Influence of the implant-abutment connection design and diameter on the screw joint stability

    PubMed Central

    Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung

    2014-01-01

    PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398

  20. Root Cause Investigation of the Starboard Solar Alpha Rotary Joint Anomaly on the International Space Station

    NASA Technical Reports Server (NTRS)

    Taylor, Deneen; Enriquez, Carlos; McCann, David; McFatter, Justin

    2010-01-01

    The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high current draw. Later inspections via Extravehicular Activity (EVA) discovered that the case hardened steel race ring on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A far-reaching investigation of the anomaly was undertaken, comprising metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The investigation found that the race ring damage had been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors.

  1. Using routine Haemophilia Joint Health Score for international comparisons of haemophilia outcome: standardization is needed.

    PubMed

    Nijdam, A; Bladen, M; Hubert, N; Pettersson, M; Bartels, B; van der Net, J; Liesner, R; Petrini, P; Kurnik, K; Fischer, K

    2016-01-01

    Haemophilia Joint Health Score (HJHS) is the most sensitive validated score for physical examination of joint health in haemophilia. HJHS performed at regular intervals can be used for clinical monitoring as well as for comparative outcomes research. To determine whether routinely collected HJHS could be used to compare outcome of three different prophylactic regimens in children with severe haemophilia A (primary) and which parameters caused variability in HJHS (secondary). International retrospective observational multi-centre study comparing routine HJHS in 127 children with severe haemophilia A born from 1995 to 2009, from London, Stockholm and Utrecht centres. Patient and treatment data were collected from the European Paediatric Network for Haemophilia Management registry and patient files. The independent effects of regimens, physiotherapists, age and inhibitor status on HJHS were explored, using multivariable regression analysis. Prophylaxis varied across participating centres, with differences in initial frequency of infusions (1× per week vs. 3× per week), age at reaching infusions ≥3× per week, and dose kg(-1) week(-1) at HJHS assessment. Evaluation at median age of 11 years showed an illogical association of HJHS with treatment regimen: the least intensive regimen had the lowest HJHS. The HJHS increased with age and history of inhibitor, as expected (internal validity). But the comparison of prophylactic regimens was obscured by systematic differences in assessment between physiotherapists, both within and between centres. Inter-physiotherapist discrepancies in routine HJHS hamper comparison of scores between treatment regimens. For multi-centre research, additional inter-observer standardization for HJHS scoring is needed. © 2015 John Wiley & Sons Ltd.

  2. SWANEA (Southwest Asia-Northeast Africa) A Climatological Study. Volume 3. The Near East Mountains

    DTIC Science & Technology

    1991-04-01

    SHIRAZ TlRA M LAT/LON: 2f 32 N 52 35 E ELEV: 4920 FT ILIHINTS JAN jFEB J MAR IAPR [MAY IJUN JJU, JAUG ISEP JOCT I NOV j DEC IAkNNJ EXT MAX 61 i75 81...M1AR APR I MAY I JUN jJUL JAUG ISEP I OCT I NOV IDE C IANN xX 5MA1 58 69 75 " ao 921 1001 98 191 j 841 67j 57’ 100 AIVG MAX .... 13 42 5 6 76 83 1 483...o t S•TATON : ESKISEHI[R T URM-’ LAT/LOI.: 39 47 N 30 34 E ELEV: 2579 FT ELEMI.-L TS !JAN FEB IMAR IAPR iHAY JUN JUL JAUG .SEP OCT NOV IDEC I NNI EXT

  3. [Internal fixation with one-hole microplate for the treatment of collateral ligament injuries of the metacarpophalangeal joint of the thumb combined with fracture].

    PubMed

    Wang, Xi-Xun; Sun, De-Tao; Chen, Xu-Hui; Li, Jun; Cui, Yan; Hu, Ji-Chao; Shu, Zheng-Hua; He, Jian; Ding, Chao-Qi; Chen, Bo

    2015-03-01

    To study clinical effects of one-hole microplate internal fixation for the treatment of collateral ligament injuries of the metacarpophalangeal joint of the thumb combined with fracture. Twenty-two patients (16 males, 6 females) with collateral ligament injuries of the metacarpophalangeal joint of the thumb combined fracture were treated with one-hole microplate internal fixation. The age of the patients ranged from 18 to 53 years old with a mean age of 28.5 years old. The duration from injury to surgery ranged from 2 hours to 2 months, and the mean time was 6 days. All the patients had collateral ligament injuries combined with fracture of the metacarpophalangeal joint of the thumb. Thirteen patients had injuries in the right hand and 9 patients had injuries in the left hand. There were 18 cases of closed wound and 4 cases of open wound. Eighteen patients had fresh injuries (< 2 weeks) and 4 had old injuries (> 2 weeks). Sixteen patients had injuries in the ulnar collateral ligament of the thumb combined with fracture, 6 patients had radial collateral ligament injuries of the thumb combined with fracture, 4 cases of which were complicated with injuries of abductor pollicis brevis and the end of the flexor pollicis brevis tender. The size of the avulsed fragment was about 3.0 mm x 4.0 mm to 6.0 mm x 7.0 mm. The incisions of 22 patients healed by first intention. The follow-up periods ranged from 6 months to 5 years old,with an average of 2.5 years old. The thumb function was evaluated by Saetta and other evaluation criteria, and 20 patients got an excellent result and 2 good. The application of one-hole microplate internal fixation in treating collateral ligament injuries with fracture of the metacarpophalangeal joint of the thumb is an effective method.

  4. 26 CFR 25.2523(d)-1 - Joint interests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 14 2011-04-01 2010-04-01 true Joint interests. 25.2523(d)-1 Section 25.2523(d... TAXES GIFT TAX; GIFTS MADE AFTER DECEMBER 31, 1954 Deductions § 25.2523(d)-1 Joint interests. Section 2523(d) provides that if a property interest is transferred to the donee spouse as sole joint tenant...

  5. [Hospital Doctors Should Receive Lecture for Sedation According to Joint Commission International].

    PubMed

    Ueshima, Hironobu; Komasawa, Nobuyasu; Kitamura, Akira

    2015-08-01

    At our hospital, intending to obtaining an approval from the Joint Commission International (JCI), we conducted a workshop on sedation for all staff physicians. A sedation instructor authorized by the Japanese Association for Medical Simulation gave a lecture using the "practice guidelines for sedation and administration of analgesics for non-anesthesiologists", revised in 2002 by the American Society of Anesthesiologists, following which, a test using 10 true-false questions was conducted, while before and after the lecture a questionnaire survey on the sedation lecture was carried out Among 191 physicians attending the lecture, except for one person, 7 or more questions were answered correctly. From the questionnaires, the sedation lectures were also generally accepted favourably. In the test of understanding, the mistakes were mostly in the sections on "sedation evaluation" "intraoperative monitoring" "pharmaceutical knowledge" and "airway management methods". The sedation lecture in the hospital was effective.

  6. IRS memorandum limits joint ventures.

    PubMed

    Herman, A W

    1992-08-01

    Based on a new memorandum, the Internal Revenue Service (IRS) will be looking at joint hospital/physician activities with greater attention to the nuances of public versus private benefit. As a result, hospitals face greater risk of losing their tax-exempt status in the maze of joint ventures, physician recruitment, and practice acquisition. To be successful, ventures will have to be backed by sound reasoning and thorough documentation.

  7. What It Takes. Air Force Command of Joint Operations

    DTIC Science & Technology

    2009-01-01

    Iraq Assistance Group IDE intermediate developmental education IO international organization ISAF International Security and Assistance Force ISR...Operations Table A.1—Continued Joint Task Force Mission/Operation Start End Service Command Rank JTF–Joint Area Support Group (JASG) Iraqi Freedom...be of interest to a wide group of Air Force personnel involved in the development and func- tion of the service’s command organizations, including

  8. Comparison of reaction forces on the anterior cruciate and anterolateral ligaments during internal rotation and anterior drawer forces at different flexion angles of the knee joint.

    PubMed

    Uğur, Levent

    2017-12-01

    Having a complicated anatomy, the knee joint has been further detailed and a new formation defined, the anterolateral ligament (ALL), in recent studies. While the importance of this ligament, which previously was associated with Segond fractures, was explained via clinical, radiologic and biomechanical studies, and basically, is thought to be a fixator structures for the tibia against internal rotation stress. Although in recent studies efficient surgical treatment was applied to patients who underwent anterior cruciate ligament (ACL) operation, some patients having a positive pivot test highlights the clinical importance of the ALL. The aim of this study is to evaluate reaction forces of different flexion angles on the tibia during internal rotation and anterior drawer tests on both the ALL and ACL, and to examine theimportance of this ligament in knee biomechanics by a finite element analysis method. In this study, normal anatomy knee joint was modelled using Computed Tomography images from lower extremity length in DICOM format. 0°, 15°,30°,45°,60°,75° and 90° angles of flexion were applied, respectively, to these models and reaction force vectors formed on both ligaments were examined separately and as total vector and size by applying internal rotation and anterior drawer forces on each model. Non-linear analysis was conducted using ANSYS (version 17) with the same limit conditions applied to all models. After all models were examined, in general when comparing reaction forces, those on the ACL were found to be higher. However, when vectoral directions were examined, forces on ALL increased with increased flexion ratio and internal rotation momentum. Beyond 30° flexion, the tensile force on the ALL is increased and compressive overload on the ACL occurs. The ALL plays an important role in stability, especially against internal rotation forces, and an increased knee joint flexion ratio increases the stability contribution ratio. In particular, at 30

  9. International consensus on the definition and classification of fibrosis of the knee joint.

    PubMed

    Kalson, N S; Borthwick, L A; Mann, D A; Deehan, D J; Lewis, P; Mann, C; Mont, M A; Morgan-Jones, R; Oussedik, S; Williams, F M K; Toms, A; Argenson, J N; Bellemans, J; Bhave, A; Furnes, O; Gollwitzer, H; Haddad, F S; Hofmann, S; Krenn, V

    2016-11-01

    The aim of this consensus was to develop a definition of post-operative fibrosis of the knee. An international panel of experts took part in a formal consensus process composed of a discussion phase and three Delphi rounds. Post-operative fibrosis of the knee was defined as a limited range of movement (ROM) in flexion and/or extension, that is not attributable to an osseous or prosthetic block to movement from malaligned, malpositioned or incorrectly sized components, metal hardware, ligament reconstruction, infection (septic arthritis), pain, chronic regional pain syndrome (CRPS) or other specific causes, but due to soft-tissue fibrosis that was not present pre-operatively. Limitation of movement was graded as mild, moderate or severe according to the range of flexion (90° to 100°, 70° to 89°, < 70°) or extension deficit (5° to 10°, 11° to 20°, > 20°). Recommended investigations to support the diagnosis and a strategy for its management were also agreed. The development of standardised, accepted criteria for the diagnosis, classification and grading of the severity of post-operative fibrosis of the knee will facilitate the identification of patients for inclusion in clinical trials, the development of clinical guidelines, and eventually help to inform the management of this difficult condition. Cite this article: Bone Joint J 2016;98-B:1479-88. ©2016 The British Editorial Society of Bone & Joint Surgery.

  10. Paired organs--Should they be treated jointly or separately in internal dosimetry?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parach, Ali-Asghar; Rajabi, Hossein; Askari, Mohammad-Ali

    2011-10-15

    Purpose: Size, shape, and the position of paired organs are different in abdomen. However, the counterpart organs are conventionally treated jointly together in internal dosimetry. This study was performed to quantify the difference of specific absorbed fraction of organs in considering paired organs jointly like single organs or as two separate organs. Methods: Zubal phantom and GATE Monte Carlo package were used to calculate the SAF for the self-absorption and cross-irradiation of the lungs, kidneys, adrenal glands (paired organs), liver, spleen, stomach, and pancreas (single organs). The activity was assumed uniformly distributed in the organs, and simulation was performed formore » monoenergetic photons of 10, 50, 100, 500, 1000 keV and mono-energetic electrons of 350, 500, 690, 935, 1200 keV. Results: The results demonstrated that self-absorption of left and right counterpart organs may be different depending upon the differences in their masses. The cross-irradiations between left-to-right and right-to-left counterpart organs are always equal irrespective of difference in their masses. Cross-irradiation from the left and right counterpart organs to other organs are different (4-24 times in Zubal phantom) depending on the photon energy and organs. The irradiation from a single source organ to the left and right counterpart paired organs is always different irrespective of activity concentration. Conclusions: Left and right counterpart organs always receive different absorbed doses from target organs and deliver different absorbed doses to target organs. Therefore, in application of radiopharmaceuticals in which the dose to the organs plays a role, counterpart organs should be treated separately as two separate organs.« less

  11. The IceCube Neutrino Observatory, the Pierre Auger Observatory and the Telescope Array: Joint Contribution to the 35th International Cosmic Ray Conference (ICRC 2017)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aartsen, M. G.; et al.

    Joint contributions of the IceCube Collaboration, the Telescope Array Collaboration, and the Pierre Auger Collaboration to the 35th International Cosmic Ray Conference (ICRC 2017), 12-20 July 2017, Bexco, Busan, Korea.

  12. Analysis of continuous beams with joint slip

    Treesearch

    L. A. Soltis

    1981-01-01

    A computer analysis with user guidelines to analyze partially continuous multi-span beams is presented. Partial continuity is due to rotational slip which occurs at spliced joints at the supports of continuous beams such as floor joists. Beam properties, loads, and joint slip are input; internal forces, reactions, and deflections are output.

  13. Official Positions for FRAX® Bone Mineral Density and FRAX® simplification from Joint Official Positions Development Conference of the International Society for Clinical Densitometry and International Osteoporosis Foundation on FRAX®.

    PubMed

    Lewiecki, E Michael; Compston, Juliet E; Miller, Paul D; Adachi, Jonathan D; Adams, Judith E; Leslie, William D; Kanis, John A; Moayyeri, Alireza; Adler, Robert A; Hans, Didier B; Kendler, David L; Diez-Perez, Adolfo; Krieg, Marc-Antoine; Masri, Basel K; Lorenc, Roman R; Bauer, Douglas C; Blake, Glen M; Josse, Robert G; Clark, Patricia; Khan, Aliya A

    2011-01-01

    Tools to predict fracture risk are useful for selecting patients for pharmacological therapy in order to reduce fracture risk and redirect limited healthcare resources to those who are most likely to benefit. FRAX® is a World Health Organization fracture risk assessment algorithm for estimating the 10-year probability of hip fracture and major osteoporotic fracture. Effective application of FRAX® in clinical practice requires a thorough understanding of its limitations as well as its utility. For some patients, FRAX® may underestimate or overestimate fracture risk. In order to address some of the common issues encountered with the use of FRAX® for individual patients, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundation (IOF) assigned task forces to review the medical evidence and make recommendations for optimal use of FRAX® in clinical practice. Among the issues addressed were the use of bone mineral density (BMD) measurements at skeletal sites other than the femoral neck, the use of technologies other than dual-energy X-ray absorptiometry, the use of FRAX® without BMD input, the use of FRAX® to monitor treatment, and the addition of the rate of bone loss as a clinical risk factor for FRAX®. The evidence and recommendations were presented to a panel of experts at the Joint ISCD-IOF FRAX® Position Development Conference, resulting in the development of Joint ISCD-IOF Official Positions addressing FRAX®-related issues. Copyright © 2011 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  14. Introduction to the special issue on the 2011 Joint IEEE International Frequency Control Symposium and European Frequency and Time Forum.

    PubMed

    Burt, Eric; Gill, Patrick

    2012-03-01

    The 8 invited and 17 contributed papers in this special issue focus on the following topical areas covered at the 2011 Joint IEEE International Frequency Control Symposium and European Frequency and Time Forum, held in San Francisco, California: 1) Materials and Resonators; 2) Oscillators, Synthesizers, and Noise; 3) Microwave Frequency Standards; 4) Sensors and Transducers; 5) Timekeeping and Time and Frequency Transfer; and 6) Optical Frequency Standards.

  15. Discrete and continuous joint coupling relationships in uninjured recreational runners.

    PubMed

    Dierks, Tracy A; Davis, Irene

    2007-06-01

    Abnormal joint coupling is thought to be related to overuse injuries in runners. However, researchers do not yet know what constitutes normal joint coupling during running, which makes abnormal coupling difficult to define. Lower extremity kinematics were collected from 40 recreational runners during stance. Joint coupling methods were applied and, for each method, means and both within- and between-subject variability were calculated. The 95% confidence interval was used to compare differences across coupling relationships and periods of stance. Timing between rearfoot eversion, tibial internal rotation, and knee flexion were relatively synchronous while relationships involving knee internal rotation were more asynchronous. The excursion ratios showed that every 2 degrees of rearfoot eversion was coupled with 1 degrees of both tibial internal rotation and knee internal rotation. Vector coding results showed that just beyond maximum loading, all joint coupling relationships resulted in relatively equal amounts of motion, while the within-subject variability was similar throughout stance. The continuous relative phase results showed that the most out-of-phase coupling occurred in the periods around heel-strike and toe-off while the most in-phase coupling occurred in the period just beyond maximum loading of the leg. The continuous relative phase within-subject variability was greatest at the periods around heel-strike and toe-off and smallest just beyond maximum loading. With a better understanding of joint coupling in uninjured runners, these data will help to serve as a reference for future studies investigating the relationship between running injuries and abnormal joint coupling.

  16. Mechanical end joint system for connecting structural column elements

    NASA Technical Reports Server (NTRS)

    Bush, Harold G. (Inventor); Mikulas, Martin M., Jr. (Inventor); Wallsom, Richard E. (Inventor)

    1990-01-01

    A mechanical end joint system is presented that eliminates the possibility of free movements between the joint halves during loading or vibration. Both node joint body (NJB) and column end joint body (CEJB) have cylindrical engaging ends. Each of these ends has an integral semicircular tongue and groove. The two joint halves are engaged transversely - the tongue of the NJB mating with the groove of the CEJB and vice versa. The joint system employs a spring loaded internal latch mechanism housed in the CEJB. During mating, this mechanism is pushed away from the NJB and enters the NJB when mating is completed. In order to lock the joint and add a preload across the tongue and groove faces, an operating ring collar is rotated through 45 deg causing an internal mechanism to compress a Belleville washer preload mechanism. This causes an equal and opposite force to be exerted on the latch bolt and the latch plunger. This force presses the two joint halves tightly together. In order to prevent inadvertent disassembly, a secondary lock is also engaged when the joint is closed. Plungers are carried in the operating ring collar. When the joint is closed, the plungers fall into tracks on the CEJB, which allows the joint to be opened only when the operating ring collar and plungers are pushed directly away from the joining end. One application of this invention is the rapid assembly and disassembly of diverse skeletal framework structures which is extremely important in many projects involving the exploration of space.

  17. Results and Analysis from Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  18. Joint contact loading in forefoot and rearfoot strike patterns during running.

    PubMed

    Rooney, Brandon D; Derrick, Timothy R

    2013-09-03

    Research concerning forefoot strike pattern (FFS) versus rearfoot strike pattern (RFS) running has focused on the ground reaction force even though internal joint contact forces are a more direct measure of the loads responsible for injury. The main purpose of this study was to determine the internal loading of the joints for each strike pattern. A secondary purpose was to determine if converted FFS and RFS runners can adequately represent habitual runners with regards to the internal joint loading. Using inverse dynamics to calculate the net joint moments and reaction forces and optimization techniques to estimate muscle forces, we determined the axial compressive loading at the ankle, knee, and hip. Subjects consisted of 15 habitual FFS and 15 habitual RFS competitive runners. Each subject ran at a preferred running velocity with their habitual strike pattern and then converted to the opposite strike pattern. Plantar flexor muscle forces and net ankle joint moments were greater in the FFS running compared to the RFS running during the first half of the stance phase. The average contact forces during this period increased by 41.7% at the ankle and 14.4% at the knee joint during FFS running. Peak ankle joint contact force was 1.5 body weights greater during FFS running (p<0.05). There was no evidence to support a difference between habitual and converted running for joint contact forces. The increased loading at the ankle joint for FFS is an area of concern for individuals considering altering their foot strike pattern. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Impact of online education on intern behaviour around joint commission national patient safety goals: a randomised trial.

    PubMed

    Shaw, Tim J; Pernar, Luise I; Peyre, Sarah E; Helfrick, John F; Vogelgesang, Kaitlin R; Graydon-Baker, Erin; Chretien, Yves; Brown, Elizabeth J; Nicholson, James C; Heit, Jeremy J; Co, John Patrick T; Gandhi, Tejal

    2012-10-01

    To compare the effectiveness of two types of online learning methodologies for improving the patient-safety behaviours mandated in the Joint Commission National Patient Safety Goals (NPSG). This randomised controlled trial was conducted in 2010 at Massachusetts General Hospital and Brigham and Women's Hospital (BWH) in Boston USA. Incoming interns were randomised to either receive an online Spaced Education (SE) programme consisting of cases and questions that reinforce over time, or a programme consisting of an online slide show followed by a quiz (SQ). The outcome measures included NPSG-knowledge improvement, NPSG-compliant behaviours in a simulation scenario, self-reported confidence in safety and quality, programme acceptability and programme relevance. Both online learning programmes improved knowledge retention. On four out of seven survey items measuring satisfaction and self-reported confidence, the proportion of SE interns responding positively was significantly higher (p<0.05) than the fraction of SQ interns. SE interns demonstrated a mean 4.79 (36.6%) NPSG-compliant behaviours (out of 13 total), while SQ interns completed a mean 4.17 (32.0%) (p=0.09). Among those in surgical fields, SE interns demonstrated a mean 5.67 (43.6%) NPSG-compliant behaviours, while SQ interns completed a mean 2.33 (17.9%) (p=0.015). Focus group data indicates that SE was more contextually relevant than SQ, and significantly more engaging. While both online methodologies improved knowledge surrounding the NPSG, SE was more contextually relevant to trainees and was engaging. SE impacted more significantly on both self-reported confidence and the behaviour of surgical residents in a simulated scenario.

  20. In vivo axial humero-ulnar rotation in normal and dysplastic canine elbow joints.

    PubMed

    Rohwedder, Thomas; Fischer, Martin; Böttcher, Peter

    2018-04-01

    To prospectively compare relative axial (internal-external) humero-ulnar rotation in normal and dysplastic canine elbow joints. Six normal elbows (five dogs) and seven joints (six dogs) with coronoid disease were examined. After implantation of 0.8 mm tantalum beads into humerus and ulna, biplanar x-ray movies of the implanted elbows were taken while dogs were walking on a treadmill. Based on the 2D bead coordinates of the synchronized x-ray movies virtual 3D humero-ulnar animations were calculated. Based on these, relative internal-external humero-ulnar rotation was measured over the first third of stance phase and expressed as maximal rotational amplitude. Amplitudes from three consecutive steps were averaged and groupwise compared using an unpaired t-test. In normal elbow joints mean axial relative humero-ulnar rotation was 2.9° (SD 1.1). Dysplastic joints showed a significantly greater rotational amplitude (5.3°, SD 2.0; p = 0.0229, 95% confidence interval 0.4-4.4). Dysplastic elbow joints show greater relative internal-external humero-ulnar rotation compared to normal elbows, which might reflect rotational joint instability. Increased relative internal-external humero-ulnar rotation might alter physiological joint contact and pressure patterns. Future studies are needed to verify if this plays a role in the pathogenesis of medial coronoid disease. Schattauer GmbH.

  1. QUANTITATIVE TOXICOLOGIC PATHOLOGY-METHODS AND INTERPRETATION' SESSION AT THE JOINT MEETING OF SOCIETY OF TOXICOLOGIC PATHOLOGISTS AND THE INTERNATIONAL FEDERATION OF SOCIETIES OF TOXICOLOGIC PATHOLOGISTS

    EPA Science Inventory

    Report of the 'Quantitative Toxicologic Pathology - Methods and Interpretation' session at the Joint meeting of Society of Toxicologic Pathologists and the International Federation of Societies of Toxicologic Pathologists, Orlando, Florida, USA, June 24-28, 2001. Douglas C. Wolf,...

  2. Prosthetic elbow joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  3. Biomechanical analysis of the influence of friction in jaw joint disorders.

    PubMed

    Koolstra, J H

    2012-01-01

    Increased friction due to impaired lubrication in the jaw joint has been considered as one of the possible causes for internal joint disorders. A very common internal disorder in the jaw joint is an anteriorly dislocated articular disc. This is generally considered to contribute to the onset of arthritic injuries. Increase of friction as caused by impairment of lubrication is suspected to be a possible cause for such a disorder. The influence of friction was addressed by analysis of its effects on tensions and deformations of the cartilaginous structures in the jaw joint using computational biomechanical analysis. Jaw open-close movements were simulated while in one or two compartments of the right joint friction was applied in the articular contact. The left joint was treated as the healthy control. The simulations predicted that friction primarily causes increased shear stress in the articular cartilage layers, but hardly in the articular disc. This suggests that impaired lubrication may facilitate deterioration of the cartilage-subchondral bone unit of the articular surfaces. The results further suggest that increased friction is not a plausible cause for turning a normally functioning articular disc into an anteriorly dislocated one. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  4. How to establish and sustain a joint venture in China.

    PubMed

    Lee, Paul

    2008-01-01

    Joint ventures with Chinese companies provide one of the most effective ways for international companies to establish a foothold in the booming Chinese economy. The benefits, opportunities and challenges of establishing a joint venture are explored here. Current partnering trends and successful Sino-foreign joint ventures in the fast-growing medical device industry in China are also highlighted.

  5. 26 CFR 20.2040-1 - Joint interests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES... owner or owners by gift, devise, bequest, or inheritance, the decedent's fractional share of the... decedent and the other joint owner or owners by gift, bequest, devise, or inheritance. (b) Meaning of...

  6. Symposium introduction: the first joint American Chemical Society Agricultural and Food Chemistry Division and the American Chemical Society International Chemical Sciences Chapter in Thailand

    USDA-ARS?s Scientific Manuscript database

    The American Chemical Society (ACS) Agricultural and Food Chemistry Division (AGFD) and the ACS International Chemical Sciences Chapter in Thailand (ICSCT) worked together to stage the “1st Joint ACS AGFD - ACS ICSCT Symposium on Agricultural and Food Chemistry,” which was held in Bangkok, Thailand ...

  7. Multilateral Biomedical Data Sharing in the One-year Joint US-Russian Mission on the International Space Station

    NASA Technical Reports Server (NTRS)

    Charles, John B.; Haven, C.; Johnson-Throop, K.; Van Baalen, M.; McFather, J.

    2014-01-01

    The One Year Mission (1YM) by two astronauts on the International Space Station (ISS), starting in March 2015, offers a unique opportunity to expand multilateral collaboration by sharing data and resources among the partner agencies in preparation for planned space exploration missions beyond low Earth orbit. Agreements and protocols will be established for the collection, distribution, analysis and reporting of both research and clinical data. Data will be shared between the agencies sponsoring the investigators, and between the research and clinical medicine communities where common interests are identified. The assignment of only two astronauts, one Russian and the other American, to the 1YM necessitated creativity in bilateral efforts to maximize the biomedical return from the opportunity. Addition of Canadian, European and Japanese investigations make the effort even more integrative. There will be three types of investigations: joint, cross-participation and data-exchange. The joint investigations have US and Russian coprincipal investigators, and the data acquired will be their common responsibility. The other two types must develop data sharing agreements and processes specific to their needs. A multilateral panel of ISS partner space agencies will develop policies for international exchange of scientific information to meet their science objectives and priorities. They will promote archiving of space flight data and will inform each other and the scientific community at large about the results obtained from space life sciences studies. Integration tasks for the 1YM are based on current experience from the ISS and previous efforts on the Russian space station Mir. Closer coordination between international partners requires more common approaches to remove barriers to multilateral resource utilization on the ISS. Greater integration in implementation should increase utilization efficiency to benefit all participants in spaceflight human research. This

  8. Quantification of disc displacement in internal derangement of the temporomandibular joint using magnetic resonance imaging.

    PubMed

    Arayasantiparb, Raweewan; Tsuchimochi, Makoto

    2010-02-01

    Many measures have been developed to determine the extent of disc displacement in internal derangements of the temporomandibular joint (TMJ) using magnetic resonance imaging. The purpose of this study was to develop a quantitative method of analyzing disc position and to evaluate the positions of the disc in internal derangements of the TMJ (group 1, with reduction; group 2, without reduction). Magnetic resonance images of 150 TMJs in 20 healthy volunteers and 55 patients with internal derangements were evaluated. The anatomical points of interest of the TMJ, including the anterior (DA) and posterior (DP) points of the disc, were marked on parasagittal magnetic resonance images of the TMJ disc taken in both the closed- and the open-mouth positions. All points were recorded using an x-y coordinate system, with reference to a referral line. In the closed-mouth position, the DP in patients in group 1 was situated in a more-anterior direction than the DP in volunteers. The DP in group 2 was located further anterior and inferior than the DP in group 1. However, the position of the DA did not differ between group 1 and group 2. In the open-mouth position, the DP was displaced anteroinferiorly to a greater extent in group 2 than in group 1 (one-way ANOVA, followed by Scheffe's test; P < 0.0001). The distance between the disc points in the closed- and open-mouth positions was also evaluated. Comparison of the disc point position in the closed- and open-mouth positions in symptomatic and asymptomatic displaced TMJ discs revealed no significant difference. In conclusion, most of our results quantitatively support previously reported findings in imaging, surgical, and histopathological studies of TMJ internal derangement. We suggest that our measure of disc position of the TMJ would be useful to assess the status and response to treatment of internal derangements of the TMJ.

  9. Impact of online education on intern behaviour around Joint Commission National Patient Safety Goals: A randomised trial

    PubMed Central

    TJ, Shaw; LIM, Pernar; SE, Peyre; JF, Helfrick; K, Vogelgesang; E, Graydon-Baker; Y, Chretien; EJ, Brown; J, Nicholson; JJ, Heit; JP, Co; TK, Gandhi

    2014-01-01

    Purpose To compare the effectiveness of 2 types of online learning methodologies for improving the patient-safety behaviours mandated in the Joint Commission National Patient Safety Goals (NPSG). Methods This randomized controlled trial was conducted in 2010 at Massachusetts General Hospital (MGH) and Brigham & Women’s Hospital (BWH) in Boston USA. Incoming interns were randomised to either receive an online Spaced Education program (SE) consisting of cases and questions that reinforce over time, or a program consisting of an online slide show followed by a quiz (SQ). The outcome measures included NPSG-knowledge improvement, NPSG-compliant behaviors in a simulation scenario, self reported confidence in safety and quality, program acceptability and program relevance. Results Both online learning programs improved knowledge retention. On four out of seven survey items measuring satisfaction and self reported confidence, the proportion of SE interns responding positively was significantly higher (p<0.05) than the fraction of SQ interns. SE interns demonstrated a mean 4.79 (36.6%) NPSG-compliant behaviors (out of 13 total), while SQ interns completed a mean 4.17 (32.0%) (p=0.09). Among those in surgical fields, SE interns demonstrated a mean 5.67 (43.6%) NPSG-compliant behaviors, while SQ interns completed a mean 2.33 (17.9%) (p=0.015). Focus group data indicates that SE was more contextually relevant than SQ and significantly more engaging. Conclusion While both online methodologies improved knowledge surrounding the NPSG, SE was more contextually relevant to trainees and engaging. SE impacted more significantly on both self reported confidence and the behaviour of surgical residents in a simulated scenario. PMID:22706930

  10. Adaptive plasticity in mammalian masticatory joints

    NASA Astrophysics Data System (ADS)

    Ravosa, Matthew J.; Kunwar, Ravinder; Nicholson, Elisabeth K.; Klopp, Emily B.; Pinchoff, Jessie; Stock, Stuart R.; Stack, M. Sharon; Hamrick, Mark W.

    2006-08-01

    Genetically similar white rabbits raised on diets of different mechanical properties, as well as wild-type and myostatin-deficient mice raised on similar diets, were compared to assess the postweaning effects of elevated masticatory loads due to increased jaw-adductor muscle and bite forces on the proportions and properties of the mandibular symphysis and temporomandibular joint (TMJ). Microcomputed tomography (microCT) was used to quantify bone structure at a series of equidistant external and internal sites in coronal sections for a series of joint locations. Discriminant function analyses and non-parametric ANOVAs were used to characterize variation in biomineralization within and between loading cohorts. In both species, long-term excessive loading results in larger joint proportions, thicker articular and cortical bone, and increased biomineralization of hard tissues. Such adaptive plasticity appears designed to maintain the postnatal integrity of masticatory joint systems for a primary loading environment(s). This behavioral signal may be increasingly mitigated in older organisms by the interplay between adaptive and degradative joint tissue responses.

  11. Knee joint mobilization reduces secondary mechanical hyperalgesia induced by capsaicin injection into the ankle joint.

    PubMed

    Sluka, K A; Wright, A

    2001-01-01

    Joint mobilization is a treatment approach commonly used by physical therapists for the management of a variety of painful conditions. However, the clinical effectiveness when compared to placebo and the neurophysiological mechanism of action are not known. The purpose of this study was to establish that application of a manual therapy technique will produce antihyperalgesia in an animal model of joint inflammation and that the antihyperalgesia produced by joint mobilization depends on the time of treatment application. Capsaicin (0.2%, 50 microl) was injected into the lateral aspect of the left ankle joint and mechanical withdrawal threshold assessed before and after capsaicin injection in Sprague-Dawley rats. Joint mobilization of the ipsilateral knee joint was performed 2 h after capsaicin injection for a total of 3 min, 9 min or 15 min under halothane anaesthesia. Control groups included animals that received halothane for the same time as the group that received joint mobilization and those whose limbs were held for the same duration as the mobilization (no halothane). Capsaicin resulted in a decreased mechanical withdrawal threshold by 2 h after injection that was maintained through 4 h. Both 9 and 15 min of mobilization, but not 3 min of mobilization, increased the withdrawal threshold to mechanical stimuli to baseline values when compared with control groups. The antihyperalgesic effect of joint mobilization lasted 30 min. Thus, joint mobilization (9 or 15 min duration) produces a significant reversal of secondary mechanical hyperalgesia induced by intra-articular injection of capsaicin. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  12. 26 CFR 1.6013-2 - Joint return after filing separate return.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the case of a joint return made under section 6013(b), the period of limitations provided in sections... (c)(1) of this section, relating to the application of sections 6501 and 6651 with respect to a joint... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Joint return after filing separate return. 1...

  13. Joint Operating Environment: The Joint Force in a Contested and Disordered World

    DTIC Science & Technology

    2016-07-14

    spilling over borders, and creating wide-ranging international problems. The future of Science, Technology, and Engineering will see others reaching...10 Science, Technology, and Engineering and the Future Joint Force ..........................................15 Summary... Engineering – may lead to new and challenging conditions that will redefine the security environment of 2035.  Section 2: Contexts of Future Conflict

  14. Internal Friction And Instabilities Of Rotors

    NASA Technical Reports Server (NTRS)

    Walton, J.; Artiles, A.; Lund, J.; Dill, J.; Zorzi, E.

    1992-01-01

    Report describes study of effects of internal friction on dynamics of rotors prompted by concern over instabilities in rotors of turbomachines. Theoretical and experimental studies described. Theoretical involved development of nonlinear mathematical models of internal friction in three joints found in turbomachinery - axial splines, Curvic(TM) splines, and interference fits between smooth cylindrical surfaces. Experimental included traction tests to determine the coefficients of friction of rotor alloys at various temperatures, bending-mode-vibration tests of shafts equipped with various joints and rotordynamic tests of shafts with axial-spline and interference-fit joints.

  15. 26 CFR 1.172-7 - Joint return by husband and wife.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... taxable year is deemed to be, in a case in which such taxable income was reported in a joint return, the... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Joint return by husband and wife. 1.172-7...-7 Joint return by husband and wife. (a) In general. This section prescribes additional rules for...

  16. Running in ostriches (Struthio camelus): three-dimensional joint axes alignment and joint kinematics.

    PubMed

    Rubenson, Jonas; Lloyd, David G; Besier, Thor F; Heliams, Denham B; Fournier, Paul A

    2007-07-01

    Although locomotor kinematics in walking and running birds have been examined in studies exploring many biological aspects of bipedalism, these studies have been largely limited to two-dimensional analyses. Incorporating a five-segment, 17 degree-of-freedom (d.f.) kinematic model of the ostrich hind limb developed from anatomical specimens, we quantified the three-dimensional (3-D) joint axis alignment and joint kinematics during running (at approximately 3.3 m s(-1)) in the largest avian biped, the ostrich. Our analysis revealed that the majority of the segment motion during running in the ostrich occurs in flexion/extension. Importantly, however, the alignment of the average flexion/extension helical axes of the knee and ankle are rotated externally to the direction of travel (37 degrees and 21 degrees , respectively) so that pure flexion and extension at the knee will act to adduct and adbuct the tibiotarsus relative to the plane of movement, and pure flexion and extension at the ankle will act to abduct and adduct the tarsometatarsus relative to the plane of movement. This feature of the limb anatomy appears to provide the major lateral (non-sagittal) displacement of the lower limb necessary for steering the swinging limb clear of the stance limb and replaces what would otherwise require greater adduction/abduction and/or internal/external rotation, allowing for less complex joints, musculoskeletal geometry and neuromuscular control. Significant rotation about the joints' non-flexion/extension axes nevertheless occurs over the running stride. In particular, hip abduction and knee internal/external and varus/valgus motion may further facilitate limb clearance during the swing phase, and substantial non-flexion/extension movement at the knee is also observed during stance. Measurement of 3-D segment and joint motion in birds will be aided by the use of functionally determined axes of rotation rather than assumed axes, proving important when interpreting the

  17. Fatigue properties of dissimilar metal laser welded lap joints

    NASA Astrophysics Data System (ADS)

    Dinsley, Christopher Paul

    This work involves laser welding austenitic and duplex stainless steel to zinc-coated mild steel, more specifically 1.2mm V1437, which is a Volvo Truck Coiporation rephosphorised mild steel. The work investigates both tensile and lap shear properties of similar and dissimilar metal laser welded butt and lap joints, with the majority of the investigation concentrating on the fatigue properties of dissimilar metal laser welded lap joints. The problems encountered when laser welding zinc-coated steel are addressed and overcome with regard to dissimilar metal lap joints with stainless steel. The result being the production of a set of guidelines for laser welding stainless steel to zinc-coated mild steel. The stages of laser welded lap joint fatigue life are defined and the factors affecting dissimilar metal laser welded lap joint fatigue properties are analysed and determined; the findings suggesting that dissimilar metal lap joint fatigue properties are primarily controlled by the local stress at the internal lap face and the early crack growth rate of the material at the internal lap face. The lap joint rotation, in turn, is controlled by sheet thickness, weld width and interfacial gap. Laser welded lap joint fatigue properties are found to be independent of base material properties, allowing dissimilar metal lap joints to be produced without fatigue failure occurring preferentially in the weaker parent material, irrespective of large base material property differences. The effects of Marangoni flow on the compositions of the laser weld beads are experimentally characterised. The results providing definite proof of the stirring mechanism within the weld pool through the use of speeds maps for chromium and nickel. Keywords: Laser welding, dissimilar metal, Zinc-coated mild steel, Austenitic stainless steel, Duplex stainless steel, Fatigue, Lap joint rotation, Automotive.

  18. [Case-control study on measurement of coracoclavicular and acromioclavicular ligament injuries during internal fixation operation for the treatment of fresh acromioclavicular joint dislocation of Tossy type III].

    PubMed

    Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang

    2014-01-01

    To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged

  19. PREFACE: International Conference on High Pressure Science and Technology, Joint AIRAPT-22 & HPCJ-50

    NASA Astrophysics Data System (ADS)

    Viña, Luis; Tejedor, Carlos; Calleja, José M.

    2010-01-01

    The International Joint AIRAPT-22 & HPCJ-50 Conference was held in Odaiba, Tokyo, on 26-31 July 2009. About 480 scientists from 24 countries attended the conference and 464 papers, including 3 plenary lectures, 39 invited talks, and 156 oral presentations, were presented. It is my great pleasure to present this proceedings volume, which is based on the high quality scientific works presented at the conference. The International AIRAPT conference has been held every two years in various countries around the world since 1965, while High Pressure Conference of Japan (HPCJ) has been held annually since 1959 in various Japanese cities. Pressure is a fundamental parameter to control the property of matter. As a result, both AIRAPT and HPCJ have become highly multidisciplinary, and cover Physics, Chemistry, Materials Science, Earth and Planetary Sciences, Biosciences, Food Science, and Technology. Although each discipline has a unique target, they all have high-pressure research in common. This proceedings volume includes about 200 papers of state-of-the-art studies from numerous fields. I hope this proceedings volume provides excellent pieces of information in various fields to further advance high-pressure research. Conference logo Takehiko Yagi Conference Chairman Institute for Solid State Physics The University of Tokyo 7 December 2009 Conference photograph Participants at the conference venue, Tokyo International Exchange Center, Odaiba, Tokyo, Japan. Editor in Chief TAKEMURA Kenichi National Institute for Materials Science, Japan Editorial board Tadashi KONDO Osaka University, Japan Hitoshi MATSUKI The University of Tokushima, Japan Nobuyuki MATUBAYASI Kyoto University, Japan Yoshihisa MORI Okayama University of Science, Japan Osamu OHTAKA Osaka University, Japan Chihiro SEKINE Muroran Institute of Technology, Japan

  20. Infant joint attention, neural networks and social cognition.

    PubMed

    Mundy, Peter; Jarrold, William

    2010-01-01

    Neural network models of attention can provide a unifying approach to the study of human cognitive and emotional development (Posner & Rothbart, 2007). In this paper we argue that a neural network approach to the infant development of joint attention can inform our understanding of the nature of human social learning, symbolic thought process and social cognition. At its most basic, joint attention involves the capacity to coordinate one's own visual attention with that of another person. We propose that joint attention development involves increments in the capacity to engage in simultaneous or parallel processing of information about one's own attention and the attention of other people. Infant practice with joint attention is both a consequence and an organizer of the development of a distributed and integrated brain network involving frontal and parietal cortical systems. This executive distributed network first serves to regulate the capacity of infants to respond to and direct the overt behavior of other people in order to share experience with others through the social coordination of visual attention. In this paper we describe this parallel and distributed neural network model of joint attention development and discuss two hypotheses that stem from this model. One is that activation of this distributed network during coordinated attention enhances the depth of information processing and encoding beginning in the first year of life. We also propose that with development, joint attention becomes internalized as the capacity to socially coordinate mental attention to internal representations. As this occurs the executive joint attention network makes vital contributions to the development of human symbolic thinking and social cognition. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Infant Joint Attention, Neural Networks and Social Cognition

    PubMed Central

    Mundy, Peter; Jarrold, William

    2010-01-01

    Neural network models of attention can provide a unifying approach to the study of human cognitive and emotional development (Posner & Rothbart, 2007). This paper we argue that a neural networks approach to the infant development of joint attention can inform our understanding of the nature of human social learning, symbolic thought process and social cognition. At its most basic, joint attention involves the capacity to coordinate one’s own visual attention with that of another person. We propose that joint attention development involves increments in the capacity to engage in simultaneous or parallel processing of information about one’s own attention and the attention of other people. Infant practice with joint attention is both a consequence and organizer of the development of a distributed and integrated brain network involving frontal and parietal cortical systems. This executive distributed network first serves to regulate the capacity of infants to respond to and direct the overt behavior of other people in order to share experience with others through the social coordination of visual attention. In this paper we describe this parallel and distributed neural network model of joint attention development and discuss two hypotheses that stem from this model. One is that activation of this distributed network during coordinated attention enhances to depth of information processing and encoding beginning in the first year of life. We also propose that with development joint attention becomes internalized as the capacity to socially coordinate mental attention to internal representations. As this occurs the executive joint attention network makes vital contributions to the development of human symbolic thinking and social cognition. PMID:20884172

  2. Gonococcal Prosthetic Joint Infection.

    PubMed

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  3. Identification of Nonlinear Micron-Level Mechanics for a Precision Deployable Joint

    NASA Technical Reports Server (NTRS)

    Bullock, S. J.; Peterson, L. D.

    1994-01-01

    The experimental identification of micron-level nonlinear joint mechanics and dynamics for a pin-clevis joint used in a precision, adaptive, deployable space structure are investigated. The force-state mapping method is used to identify the behavior of the joint under a preload. The results of applying a single tension-compression cycle to the joint under a tensile preload are presented. The observed micron-level behavior is highly nonlinear and involves all six rigid body motion degrees-of-freedom of the joint. it is also suggests that at micron levels of motion modelling of the joint mechanics and dynamics must include the interactions between all internal components, such as the pin, bushings, and the joint node.

  4. [Fetal bone and joint disorders].

    PubMed

    Jakobovits, Akos

    2008-12-21

    The article discusses the physiology and pathology of fetal bone and joint development and functions. The bones provide static support for the body. The skull and the bones of spinal column encase the central and part of the peripheral nervous system. The ribs and the sternum shield the heart and the lungs, while the bones of the pelvis protect the intraabdominal organs. Pathological changes of these bony structures may impair the functions of the respective systems or internal organs. Movements of the bones are brought about by muscles. The deriving motions are facilitated by joints. Bony anomalies of the extremities limit their effective functions. Apart from skeletal and joint abnormalities, akinesia may also be caused by neurological, muscular and skin diseases that secondarily affect the functions of bones and joints. Such pathological changes may lead to various degrees of physical disability and even to death. Some of the mentioned anomalies are recognizable in utero by ultrasound. The diagnosis may serve as medical indication for abortion in those instances when the identified abnormality is incompatible with independent life.

  5. Application of numerical method in calculating the internal rate of return of joint venture investment using diminishing musyarakah model

    NASA Astrophysics Data System (ADS)

    Ruslan, Siti Zaharah Mohd; Jaffar, Maheran Mohd

    2017-05-01

    Islamic banking in Malaysia offers variety of products based on Islamic principles. One of the concepts is a diminishing musyarakah. The concept of diminishing musyarakah helps Muslims to avoid transaction which are based on riba. The diminishing musyarakah can be defined as an agreement between capital provider and entrepreneurs that enable entrepreneurs to buy equity in instalments where profits and losses are shared based on agreed ratio. The objective of this paper is to determine the internal rate of return (IRR) for a diminishing musyarakah model by applying a numerical method. There are several numerical methods in calculating the IRR such as by using an interpolation method and a trial and error method by using Microsoft Office Excel. In this paper we use a bisection method and secant method as an alternative way in calculating the IRR. It was found that the diminishing musyarakah model can be adapted in managing the performance of joint venture investments. Therefore, this paper will encourage more companies to use the concept of joint venture in managing their investments performance.

  6. 26 CFR 25.2523(d)-1 - Joint interests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) ESTATE AND GIFT TAXES GIFT TAX; GIFTS MADE AFTER DECEMBER 31, 1954 Deductions § 25.2523(d)-1 Joint interests. Section..., if the donor purchased real property in the name of the donor and the donor's spouse as tenants by...

  7. 76 FR 5224 - Joint Industry Plan; Notice of Filing of Amendment No. 25 to the Joint Self-Regulatory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    ... Collection, Consolidation and Dissemination of Quotation and Transaction Information for Nasdaq-Listed... Exchange, Inc., EDGX Exchange, Inc., Financial Industry Regulatory Authority, Inc., International... Joint Self-Regulatory Organization Plan Governing the Collection, Consolidation, and Dissemination of...

  8. Radiological evaluation of ankle arthrodesis with Ilizarov fixation compared to internal fixation.

    PubMed

    Morasiewicz, Piotr; Dejnek, Maciej; Urbański, Wiktor; Dragan, Szymon Łukasz; Kulej, Mirosław; Dragan, Szymon Feliks

    2017-07-01

    We asked whether the type of ankle joint arthrodesis stabilization will affect: (1) rate of union, (2) rate of adjacted-joint arthritis, (3) malalignment of the ankle joint. We retrospectively radiological studied 62 patients who underwent ankle arthrodesis with Ilizarov external fixator stabilization (group 1,n=29) or internal stabilization (group 2,n=33) from 2006 to 2015. Radiologic outcomes were mesure by: (1) rate of union, (2) rate of adjacent-joint arthritis, (3) malalignment of the ankle joint. The Levene's test,Mann-Whitney U test and Students t-test were used to the statistical analyses. Ankle fusion was achieved in 100% of patients treated with external fixation and in 88% with internal stabilization. Desired frontal plane alignment was achieved in 100% of patients with external fixation and 76% with internal stabilization. Desired sagittal plane alignment was achieved in 100% of external fixation and 85% of internal stabilization. A total of 14 (48.3%) patients from group 1 showed a radiographic evidence of pre-existing adjacent-joint OA. The radiographic evidence of pre-existing adjacent-joint OA was also found in 27(81.8%) subjects from group 2. Alterations of adjacent joints were also found on postoperative radiograms of 19 (65.5%) patients subjected to Ilizarov fixation and in all 33 patients from group 2. Ilizarov fixation of ankle arthrodesis is associated with lower prevalence of adjacent-joint OA and ankle joint misalignment,and with higher fusion rates than after internal fixation.Although achieving a complex ankle fusion is generally challenging,radiological outcomes after fixation with the Ilizarov apparatus are better than after internal stabilization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Arthroscopically Assisted Reconstruction of Acute Acromioclavicular Joint Dislocations: Anatomic AC Ligament Reconstruction With Protective Internal Bracing—The “AC-RecoBridge” Technique

    PubMed Central

    Izadpanah, Kaywan; Jaeger, Martin; Ogon, Peter; Südkamp, Norbert P.; Maier, Dirk

    2015-01-01

    An arthroscopically assisted technique for the treatment of acute acromioclavicular joint dislocations is presented. This pathology-based procedure aims to achieve anatomic healing of both the acromioclavicular ligament complex (ACLC) and the coracoclavicular ligaments. First, the acromioclavicular joint is reduced anatomically under macroscopic and radiologic control and temporarily transfixed with a K-wire. A single-channel technique using 2 suture tapes provides secure coracoclavicular stabilization. The key step of the procedure consists of the anatomic repair of the ACLC (“AC-Reco”). Basically, we have observed 4 patterns of injury: clavicular-sided, acromial-sided, oblique, and midportion tears. Direct and/or transosseous ACLC repair is performed accordingly. Then, an X-configured acromioclavicular suture tape cerclage (“AC-Bridge”) is applied under arthroscopic assistance to limit horizontal clavicular translation to a physiological extent. The AC-Bridge follows the principle of internal bracing and protects healing of the ACLC repair. The AC-Bridge is tightened on top of the repair, creating an additional suture-bridge effect and promoting anatomic ACLC healing. We refer to this combined technique of anatomic ACLC repair and protective internal bracing as the “AC-RecoBridge.” A detailed stepwise description of the surgical technique, including indications, technical pearls and pitfalls, and potential complications, is given. PMID:26052493

  10. U.S. Perspectives on the Joint Convention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strosnider, J.; Federline, M.; Camper, L.

    The Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management (Joint Convention) is an international convention, under the auspices of the International Atomic Energy Agency (IAEA). It is a companion to a suite of international conventions on nuclear safety and physical security, which serve to promote a global culture for the safe use of radioactive materials. Although the U.S. was the first nation to sign the Joint Convention on September 29, 1997, the ratification process was a challenging experience for the U.S., in the face of legislative priorities dominated by concerns formore » national security and threats from terrorism after September 11, 2001. Notwithstanding these prevailing circumstances, the U.S. ratified the Joint Convention in 2003, just prior to the First Review Meeting of the Contracting Parties, and participated fully therein. For the United States, participation as a Contracting Party provides many benefits. These range from working with other Parties to harmonize international approaches to achieve strong and effective nuclear safety programs on a global scale, to stimulating initiatives to improve safety systems within our own domestic programs, to learning about technical innovations by other Parties that can be useful to U.S. licensees, utilities, and industry in managing safety and its associated costs in our waste management activities. The Joint Convention process also provides opportunities to identify future areas of bilateral and multilateral technical and regulatory cooperation with other Parties, as well as an opportunity for U.S. vendors and suppliers to broaden their market to include foreign clients for safety improvement equipment and services. The Joint Convention is consistent with U.S. foreign policy considerations to support, as a priority, the strengthening of the worldwide safety culture in the use of nuclear energy. Because of its many benefits, we believe it is important

  11. 78 FR 66788 - Joint Industry Plan; Order Approving Amendment No. 30 to the Joint Self-Regulatory Organization...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-06

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-70793; File No. S7-24-89] Joint Industry Plan..., Consolidation and Dissemination of Quotation and Transaction Information for Nasdaq-Listed Securities Traded on... Exchange, Inc., Financial Industry Regulatory Authority, Inc., International Securities Exchange LLC...

  12. Alloplastic total temporomandibular joint replacements: do they perform like natural joints? Prospective cohort study with a historical control.

    PubMed

    Wojczyńska, A; Leiggener, C S; Bredell, M; Ettlin, D A; Erni, S; Gallo, L M; Colombo, V

    2016-10-01

    The aim of this study was to qualitatively and quantitatively describe the biomechanics of existing total alloplastic reconstructions of temporomandibular joints (TMJ). Fifteen patients with unilateral or bilateral TMJ total joint replacements and 15 healthy controls were evaluated via dynamic stereometry technology. This non-invasive method combines three-dimensional imaging of the subject's anatomy with jaw tracking. It provides an insight into the patient's jaw joint movements in real time and provides a quantitative evaluation. The patients were also evaluated clinically for jaw opening, protrusive and laterotrusive movements, pain, interference with eating, and satisfaction with the joint replacements. The qualitative assessment revealed that condyles of bilateral total joint replacements displayed similar basic motion patterns to those of unilateral prostheses. Quantitatively, mandibular movements of artificial joints during opening, protrusion, and laterotrusion were all significantly shorter than those of controls. A significantly restricted mandibular range of motion in replaced joints was also observed clinically. Fifty-three percent of patients suffered from chronic pain at rest and 67% reported reduced chewing function. Nonetheless, patients declared a high level of satisfaction with the replacement. This study shows that in order to gain a comprehensive understanding of complex therapeutic measures, a multidisciplinary approach is needed. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. 22 CFR 228.34 - Joint ventures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Joint ventures. 228.34 Section 228.34 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT RULES ON SOURCE, ORIGIN AND NATIONALITY FOR COMMODITIES AND SERVICES FINANCED BY USAID Conditions Governing the Nationality of Suppliers of Services for USAID...

  14. Imaging of the temporomandibular joint: An update

    PubMed Central

    Bag, Asim K; Gaddikeri, Santhosh; Singhal, Aparna; Hardin, Simms; Tran, Benson D; Medina, Josue A; Curé, Joel K

    2014-01-01

    Imaging of the temporomandibular joint (TMJ) is continuously evolving with advancement of imaging technologies. Many different imaging modalities are currently used to evaluate the TMJ. Magnetic resonance imaging is commonly used for evaluation of the TMJ due to its superior contrast resolution and its ability to acquire dynamic imaging for demonstration of the functionality of the joint. Computed tomography and ultrasound imaging have specific indication in imaging of the TMJ. This article focuses on state of the art imaging of the temporomandibular joint. Relevant normal anatomy and biomechanics of movement of the TMJ are discussed for better understanding of many TMJ pathologies. Imaging of internal derangements is discussed in detail. Different arthropathies and common tumors are also discussed in this article. PMID:25170394

  15. 75 FR 11999 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-12

    ... Panel is soliciting public comment, ideas, and suggestions on improving customer service at the Internal... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS) Treasury. ACTION: Notice of Meeting. SUMMARY: An...

  16. Functional range of motion of the hand joints in activities of the International Classification of Functioning, Disability and Health.

    PubMed

    Gracia-Ibáñez, Verónica; Vergara, Margarita; Sancho-Bru, Joaquín L; Mora, Marta C; Piqueras, Catalina

    Cross-sectional research design. Active range of motion (AROM) is used as indicator of hand function. However, functional range of motion (FROM) data are limited, and fail to represent activities of daily living (ADL). To estimate dominant hand FROM in flexion, abduction and palmar arching in people under 50 years of age performing ADL. AROMs and hand postures in 24 representative ADL of the International Classification of Functioning, Disability and Health (ICF) were recorded in 12 men and 12 women. FROM data were reported by activity and ICF area, and compared with AROMs. The relationship between ROM measures to gender and hand size was analyzed by correlation. FROM was 5° to 28° less than available AROM depending on the joint and movement performed. Joints do not necessarily move through full AROM while performing ADL which has benefits in retaining function despite loss of motion. This may also suggest that ADL alone are insufficient to retain or restore full AROM. Therapists should consider FROM requirements and normal AROM when defining hand therapy goals, interventions and evaluating the success of treatment. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  17. Proceedings of the frst joint american chemical society agricultural and food chemistry division – american chemical society international chemical sciences chapter in Thailand symposium on agricultural and food chemistry

    USDA-ARS?s Scientific Manuscript database

    This Proceedings is a compilation of papers from contributed oral and poster presentations presented at the first joint symposium organized by the American Chemical Society Agricultural and Food Chemistry Division and the American Chemical Society International Chemical Sciences Chapter in Thailand ...

  18. Hip and knee joint loading during vertical jumping and push jerking

    PubMed Central

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony MJ

    2014-01-01

    Background The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. Methods In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. Findings The knee experienced mean peak loadings of 2.4-4.6 × body weight at the patellofemoral joint, 6.9-9.0 × body weight at the tibiofemoral joint, 0.3-1.4 × body weight anterior tibial shear and 1.0-3.1 × body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4 × body weight and the ankle 8.9-10.0 × body weight. Interpretation The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. PMID:23146164

  19. 78 FR 48231 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-07

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel... open meeting of the Taxpayer Advocacy Panel Joint Committee will be conducted. The Taxpayer Advocacy...) that an open meeting of the Taxpayer Advocacy Panel Joint Committee will be held Wednesday, September...

  20. The sacroiliac joint: anatomy, physiology and clinical significance.

    PubMed

    Forst, Stacy L; Wheeler, Michael T; Fortin, Joseph D; Vilensky, Joel A

    2006-01-01

    The sacroiliac joint (SIJ) is a putative source of low back pain. The objective of this article is to provide clinicians with a concise review of SIJ structure and function, diagnostic indicators of SIJ-mediated pain, and therapeutic considerations. The SIJ is a true diarthrodial joint with unique characteristics not typically found in other diarthrodial joints. The joint differs with others in that it has fibrocartilage in addition to hyaline cartilage, there is discontinuity of the posterior capsule, and articular surfaces have many ridges and depressions. The sacroiliac joint is well innervated. Histological analysis of the sacroiliac joint has verified the presence of nerve fibers within the joint capsule and adjoining ligaments. It has been variously described that the sacroiliac joint receives its innervation from the ventral rami of L4 and L5, the superior gluteal nerve, and the dorsal rami of L5, S1, and S2, or that it is almost exclusively derived from the sacral dorsal rami. Even though the sacroiliac joint is a known putative source of low back and lower extremity pain, there are few findings that are pathognomonic of sacroiliac joint pain. The controlled diagnostic blocks utilizing the International Association for the Study of Pain (IASP) criteria demonstrated the prevalence of pain of sacroiliac joint origin in 19% to 30% of the patients suspected to have sacroiliac joint pain. Conservative management includes manual medicine techniques, pelvic stabilization exercises to allow dynamic postural control, and muscle balancing of the trunk and lower extremities. Interventional treatments include sacroiliac joint, intra-articular joint injections, radiofrequency neurotomy, prolotherapy, cryotherapy, and surgical treatment. The evidence for intra-articular injections and radiofrequency neurotomy has been shown to be limited in managing sacroiliac joint pain.

  1. Use of Joint Commission International Standards to Evaluate and Improve Pediatric Oncology Nursing Care in Guatemala

    PubMed Central

    Day, Sara W.; McKeon, Leslie M.; Garcia, Jose; Wilimas, Judith A.; Carty, Rita M.; de Alarcon, Pedro; Antillon, Federico; Howard, Scott C.

    2017-01-01

    Background Inadequate nursing care is a major impediment to development of effective programs for treatment of childhood cancer in low-income countries. When the International Outreach Program at St. Jude Children’s Research Hospital established partner sites in low-income countries, few nurses had pediatric oncology skills or experience. A comprehensive nursing program was developed to promote the provision of quality nursing care, and in this manuscript we describe the program’s impact on 20 selected Joint Commission International (JCI) quality standards at the National Pediatric Oncology Unit in Guatemala. We utilized JCI standards to focus the nursing evaluation and implementation of improvements. These standards were developed to assess public hospitals in low-income countries and are recognized as the gold standard of international quality evaluation. Methods We compared the number of JCI standards met before and after the nursing program was implemented using direct observation of nursing care; review of medical records, policies, procedures, and job descriptions; and interviews with staff. Results In 2006, only 1 of the 20 standards was met fully, 2 partially, and 17 not met. In 2009, 16 were met fully, 1 partially, and 3 not met. Several factors contributed to the improvement. The pre-program quality evaluation provided objective and credible findings and an organizational framework for implementing change. The medical, administrative, and nursing staff worked together to improve nursing standards. Conclusion A systematic approach and involvement of all hospital disciplines led to significant improvement in nursing care that was reflected by fully meeting 16 of 20 standards. PMID:23015363

  2. Joint Discussion 14 Modeling dense stellar systems

    NASA Astrophysics Data System (ADS)

    Sills, Alison I.; Subr, Ladislav; Portegies Zwart, Simon F.

    2007-08-01

    Joint Discussion 14 was held at the General Assembly of the International Astronomical Union from August 17 until 23 in the beautiful Bohemian capital, Prague. The blueprints for this meeting were laid out during the MODEST-5 workshop, held in the Canadian city of Hamilton, Ontario in August 2004. We were sitting in a nice cafe with local brew and food, discussing the future of the MODEST community when we posed the idea for this Joint Discussion at the General Assembly. The meeting was then coined MODEST-7.

  3. Surgical Approaches to the Proximal Interphalangeal Joint.

    PubMed

    Cheah, Andre Eu-Jin; Yao, Jeffrey

    2016-02-01

    The proximal interphalangeal (PIP) joint may be affected by many conditions such as arthropathy, fractures, dislocations, and malunions. Whereas some of these conditions may be treated nonsurgically, many require open surgical intervention. Open interventions include implant arthroplasty or arthrodesis for arthropathy, open reduction internal fixation, or hemi-hamate arthroplasty for dorsal fracture-dislocations. Volar plate arthroplasty and corrective osteotomy for malunion about the PIP joint are also surgeries that may be required. The traditional approach to the PIP joint has been dorsal, which damages the delicate extensor apparatus with subsequent development of an extensor lag. This has led surgeons to explore volar and lateral approaches to the PIP joint. In this article, we describe each of these surgical approaches, discuss their advantages and disadvantages, and provide some guidance on which approach to choose based on the surgery that is to be performed. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. New International School Library Guidelines

    ERIC Educational Resources Information Center

    Oberg, Dianne

    2018-01-01

    The publication in 2015 of new international school library guidelines was the culmination of a two-year process involving a wide network of contributors. The process was guided by the Joint Committee of the International Federation of Library Associations (IFLA) School Libraries Section and the International Association of School Librarianship…

  5. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a

  6. 78 FR 36303 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel... open meeting of the Taxpayer Advocacy Panel Joint Committee will be conducted. The Taxpayer Advocacy... open meeting of the Taxpayer Advocacy Panel Joint Committee will be held Wednesday, July 24, 2013 at 2...

  7. 77 FR 40410 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel... open meeting of the Taxpayer Advocacy Panel Joint Committee will be conducted. The Taxpayer Advocacy...) that an open meeting of the Taxpayer Advocacy Panel Joint Committee will be held Wednesday, August 22...

  8. [Displacement and tissue remodeling of temporomandibular joint disc].

    PubMed

    Wang, M Q

    2017-03-09

    Sounding takes the highest prevalence of the signs of temporomandibular disorders (TMD). The well accepted theory of the mechanism for temporomandibular joint (TMJ) sounding is the internal derangement typically characterized by disc displacement. However, according to literature, there are approximately one third of asymptomatic joints in population had disc displacement, and, on the other hand, there are one fourth of TMJ sounding patients had not signs or very limited signs of disc displacement. Replacing the displaced disc to the normal position via methods like surgical operation did not achieve satisfactory long-term outcomes. In this review, we discuss and analyze the possible remodeling of the joint disc displacement diagnosed with imaging based on the anatomy and pathophysiology.

  9. 26 CFR 1.6013-3 - Treatment of joint return after death of either spouse.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... joint return after death of either spouse. For purposes of section 21 (relating to change in rates... 26 Internal Revenue 13 2012-04-01 2012-04-01 false Treatment of joint return after death of either... because of death of either spouse, the joint return shall be treated as if the taxable years of both ended...

  10. 26 CFR 1.6013-3 - Treatment of joint return after death of either spouse.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... joint return after death of either spouse. For purposes of section 21 (relating to change in rates... 26 Internal Revenue 13 2011-04-01 2011-04-01 false Treatment of joint return after death of either... because of death of either spouse, the joint return shall be treated as if the taxable years of both ended...

  11. 26 CFR 1.6013-3 - Treatment of joint return after death of either spouse.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... joint return after death of either spouse. For purposes of section 21 (relating to change in rates... 26 Internal Revenue 13 2014-04-01 2014-04-01 false Treatment of joint return after death of either... because of death of either spouse, the joint return shall be treated as if the taxable years of both ended...

  12. 26 CFR 1.6013-3 - Treatment of joint return after death of either spouse.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... joint return after death of either spouse. For purposes of section 21 (relating to change in rates... 26 Internal Revenue 13 2013-04-01 2013-04-01 false Treatment of joint return after death of either... because of death of either spouse, the joint return shall be treated as if the taxable years of both ended...

  13. The Joint Convention - Its Structure, the Articles and its Administration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metcalf, P.; Louvat, D.

    The objective of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management (The Joint Convention) is to achieve a high level of safety worldwide in the management of spent nuclear and fuel and radioactive waste. [1] It is an incentive convention designed to encourage and assist countries to achieve the objective. Contracting Parties to the Joint Convention are required to compile and submit a national report on how they meet the articles of the Joint Convention. The reports are peer reviewed by other Contracting Parties to the Joint Convention and thenmore » countries have to defend the report at a review meeting of all the Contracting Parties. The process entails both a self appraisal in compiling the report and independent international peer review. Summaries are compiled of the various reviews and these are presented in plenary, with a view to identifying generic issues and areas in which countries are improving safety or have identified for further development. The process also presents an opportunity for countries involved to benchmark their national spent fuel and radioactive waste safety programmes against prevailing international practice. The paper elaborates the detailed elements involved and discusses the experience from the first review meeting of Contracting Parties, and issues envisaged for consideration at the second review meeting scheduled for May 2006. (authors)« less

  14. Hip and knee joint loading during vertical jumping and push jerking.

    PubMed

    Cleather, Daniel J; Goodwin, Jon E; Bull, Anthony M J

    2013-01-01

    The internal joint contact forces experienced at the lower limb have been frequently studied in activities of daily living and rehabilitation activities. In contrast, the forces experienced during more dynamic activities are not well understood, and those studies that do exist suggest very high degrees of joint loading. In this study a biomechanical model of the right lower limb was used to calculate the internal joint forces experienced by the lower limb during vertical jumping, landing and push jerking (an explosive exercise derived from the sport of Olympic weightlifting), with a particular emphasis on the forces experienced by the knee. The knee experienced mean peak loadings of 2.4-4.6×body weight at the patellofemoral joint, 6.9-9.0×body weight at the tibiofemoral joint, 0.3-1.4×body weight anterior tibial shear and 1.0-3.1×body weight posterior tibial shear. The hip experienced a mean peak loading of 5.5-8.4×body weight and the ankle 8.9-10.0×body weight. The magnitudes of the total (resultant) joint contact forces at the patellofemoral joint, tibiofemoral joint and hip are greater than those reported in activities of daily living and less dynamic rehabilitation exercises. The information in this study is of importance for medical professionals, coaches and biomedical researchers in improving the understanding of acute and chronic injuries, understanding the performance of prosthetic implants and materials, evaluating the appropriateness of jumping and weightlifting for patient populations and informing the training programmes of healthy populations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Design of a knee joint mechanism that adapts to individual physiology.

    PubMed

    Jiun-Yih Kuan; Pasch, Kenneth A; Herr, Hugh M

    2014-01-01

    This paper describes the design of a new knee joint mechanism, called the Adaptive Coupling Joint (ACJ). The new mechanism has an adaptive trajectory of the center of rotations (COR) that automatically matches those of the attached biological joint. The detailed design is presented as well as characterization results of the ACJ. Conventional exoskeleton and assistive devices usually consider limb joints as a one to three degrees of freedom (DOFs) joint synthesized by multiple one-DOF hinge joints in a single plane. However, the biological joints are complex and usually rotate with respect to a changing COR. As a result, the mismatch between limb joint motion and mechanical interface motion can lead to forces that cause undesired ligament and muscle length changes and internal mechanical changes. These undesired changes contribute to discomfort, as well as to the slippage and sluggish interaction between humans and devices. It is shown that the ACJ can transmit planetary torques from either active or passive devices to the limbs without altering the normal biological joint motion.

  16. Gender differences exist in the hip joint moments of healthy older walkers.

    PubMed

    Boyer, Katherine A; Beaupre, Gary S; Andriacchi, Thomas P

    2008-12-05

    Gender differences in the incidence of symptomatic hip osteoarthritis (OA), changes in hip cartilage volume and hip joint space and rates hip arthroplasty of older people are reported in the literature. As the rate of progression of OA is in part mechanically modulated it is possible that this gender bias may be related to inherent differences (if they exist) in walking mechanics between older males and females. The purpose of this study was to examine potential mechanisms for gender differences in hip joint mechanics during walking by testing the hypotheses that females would exhibit higher hip flexion, adduction and internal rotation moments but not significantly greater normalized ground reaction forces (GRFs). Forty-two healthy subjects (21 male, 21 female), ages 50-79yr were recruited for gait analysis. In support of the hypotheses, greater external hip adduction and internal rotation along with hip extension moments were found for females compared to males after normalizing for body size for all self-selected walking speeds. Differences in walking style (kinematics) were the main determinants in the joint kinetic differences as no differences in the normalized GRFs were found. As external joint moments are surrogate measures of the joint contact forces, the results of this study suggest the hip joint stress for the female population is higher compared to male population. This is in favor of a hypothesis that the increased joint contact stress in a female population could contribute to a greater joint degeneration at the hip in females as compared with males.

  17. A Method for and Issues Associated with the Determination of Space Suit Joint Requirements

    NASA Technical Reports Server (NTRS)

    Matty, Jennifer E.; Aitchison, Lindsay

    2010-01-01

    This joint mobility KC lecture included information from two papers, "A Method for and Issues Associated with the Determination of Space Suit Joint Requirements" and "Results and Analysis from Space Suit Joint Torque Testing," as presented for the International Conference on Environmental Systems in 2009 and 2010, respectively. The first paper discusses historical joint torque testing methodologies and approaches that were tested in 2008 and 2009. The second paper discusses the testing that was completed in 2009 and 2010.

  18. Planning and implementing forest operations to achieve sustainable forests: Proceedings of papers presented at the joint meeting of the Council on Forest Engineering and International Union of Forest Research Organizations.

    Treesearch

    Charles R. Blinn; Michael A. Thompson

    1996-01-01

    Contains a variety of papers presented at the joint meeting of the Council on Forest Engineering and International Union of Forest Research Organizations Subject Group S3.04 and that support the meeting theme "Planning and Implementing Forest Operations to Achieve Sustainable Forests."

  19. International Intelligence Forum 2002

    DTIC Science & Technology

    2002-01-01

    International Intelligence Forum 2002 PCN 46737 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection...Intelligence Forum 2002 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f...Std Z39-18 INTERNATIONAL INTELLIGENCE FORUM -3 The Joint Military Intelligence College created the International Intelligence Fellows Program

  20. An empirical investigation of for-profit and tax-exempt nonprofit hospitals engaged in joint ventures.

    PubMed

    Smith, Pamela C

    2004-01-01

    Joint ventures between nonprofit and for-profit hospitals offer opportunities for collaboration to increase efficiency. These transactions have attracted the attention of the Internal Revenue Service, which may threaten tax-exempt status. This article analyzes inherent financial characteristics of nonprofit hospitals that joint venture with for-profit hospitals and those that choose not to joint venture.

  1. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

    PubMed

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo

    2014-12-01

    This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

  2. Decentralized control of large flexible structures by joint decoupling

    NASA Technical Reports Server (NTRS)

    Su, Tzu-Jeng; Juang, Jer-Nan

    1994-01-01

    This paper presents a novel method to design decentralized controllers for large complex flexible structures by using the idea of joint decoupling. Decoupling of joint degrees of freedom from the interior degrees of freedom is achieved by setting the joint actuator commands to cancel the internal forces exerting on the joint degrees of freedom. By doing so, the interactions between substructures are eliminated. The global structure control design problem is then decomposed into several substructure control design problems. Control commands for interior actuators are set to be localized state feedback using decentralized observers for state estimation. The proposed decentralized controllers can operate successfully at the individual substructure level as well as at the global structure level. Not only control design but also control implementation is decentralized. A two-component mass-spring-damper system is used as an example to demonstrate the proposed method.

  3. Overview of Carbon Dioxide Control Issues During International Space Station/Space Shuttle Joint Docked Operations

    NASA Technical Reports Server (NTRS)

    Matty, Christopher M.

    2010-01-01

    Crewed space vehicles have a common requirement to remove the carbon dioxide (CO2) created by the metabolic processes of the crew. The space shuttle [Space Transportation System (STS)] and International Space Station (ISS) each have systems in place that allow control and removal of CO2 from the habitable cabin environment. During periods in which the space shuttle is docked to the ISS, known as "joint docked operations," the space shuttle and ISS share a common atmosphere environment. During this period, an elevated amount of CO2 is produced through the combined metabolic activity of the STS and ISS crews. This elevated CO2 production, together with the large effective atmosphere created by collective volumes of the docked vehicles, creates a unique set of requirements for CO2 removal. This paper will describe individual CO2 control plans implemented by STS and ISS engineering teams, as well as the integrated plans used when both vehicles are docked. The paper will also discuss some of the issues and anomalies experienced by both engineering teams.

  4. Overview of Carbon Dioxide Control Issues During International Space Station/Space Shuttle Joint Docked Operations

    NASA Technical Reports Server (NTRS)

    Matty, Christopher M.; Hayley, Elizabeth P.

    2009-01-01

    Manned space vehicles have a common requirement to remove the Carbon Dioxide (CO2) created by the metabolic processes of the crew. The Space Shuttle and International Space Station (ISS) each have systems in place to allow control and removal of CO2 from the habitable cabin environment. During periods where the Space Shuttle is docked to ISS, known as joint docked operations, the Space Shuttle and ISS share a common atmosphere environment. During this period there is an elevated production of CO2 caused by the combined metabolic activity of the Space Shuttle and ISS crew. This elevated CO2 production, combined with the large effective atmosphere created by the collective volumes of the docked vehicles, creates a unique set of requirements for CO2 removal. This paper will describe the individual CO2 control plans implemented by the Space Shuttle and ISS engineering teams, as well as the integrated plans used when both vehicles are docked. In addition, the paper will discuss some of the issues and anomalies experienced by both engineering teams.

  5. 76 FR 37197 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  6. 78 FR 15126 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-08

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  7. 77 FR 61054 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  8. 77 FR 21156 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  9. 77 FR 8327 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS) Treasury. ACTION: Notice of meeting. SUMMARY: An...

  10. 77 FR 5313 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-02

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  11. 78 FR 11277 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-15

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of Meeting. SUMMARY: An...

  12. 77 FR 20488 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS) Treasury. ACTION: Notice of meeting. SUMMARY: An...

  13. 76 FR 6190 - Open Meeting of the Taxpayer Advocacy Panel Joint Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-03

    ... Panel is soliciting public comments, ideas, and suggestions on improving customer service at the... DEPARTMENT OF THE TREASURY Internal Revenue Service Open Meeting of the Taxpayer Advocacy Panel Joint Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Notice of meeting. SUMMARY: An...

  14. Flaw Tolerance in Lap Shear Brazed Joints. Part 1

    NASA Technical Reports Server (NTRS)

    Flom, Yury; Wang, Li-Qin

    2003-01-01

    Furnace brazing is a joining process used in the aerospace and other industries to produce strong permanent and hermetic structural joints. As in any joining process, brazed joints have various imperfections and defects. At the present time, our understanding of the influence of the internal defects on the strength of the brazed joints is not adequate. The goal of this 3-part investigation is to better understand the properties and failure mechanisms of the brazed joints containing defects. This study focuses on the behavior of the brazed lap shear joints because of their importance in manufacturing aerospace structures. In Part 1, an average shear strength capability and failure modes of the single lap joints are explored. Stainless steel specimens brazed with pure silver are tested in accordance with the AWS C3.2 standard. Comparison of the failure loads and the ultimate shear strength with the Finite Element Analysis (FEA) of the same specimens as a function of the overlap widths shows excellent correlation between the experimental and calculated values for the defect-free lap joints. A damage zone criterion is shown to work quite well in understanding the failure of the braze joints. In Part 2, the findings of the Part 1 will be verified on the larger test specimens. Also, various flaws will be introduced in the test specimens to simulate lack of braze coverage in the lap joints. Mechanical testing and FEA will be performed on these joints to verify that behavior of the flawed ductile lap joints is similar to joints with a reduced braze area. Finally, in Part 3, the results obtained in Parts 1 and 2 will be applied to the actual brazed structure to evaluate the load-carrying capability of a structural lap joint containing discontinuities. In addition, a simplified engineering procedure will be offered for the laboratory testing of the lap shear specimens.

  15. Aft segment dome-to-stiffener factory joint insulation void elimination

    NASA Technical Reports Server (NTRS)

    Jensen, S. K.

    1991-01-01

    Since the detection of voids in the internal insulation of the dome-to-stiffener factory joint of the 15B aft segment, all aft segment dome-to-stiffener factory joints were x-rated and all were found to contain voids. Using a full-scale process simulation article (PSA), the objective was to demonstrate that the proposed changes in the insulation layup and vacuum bagging processes will greatly reduce or eliminate voids without adversely affecting the configuration of performance of the insulation which serves as a primary seal over the factory joint. The PSA-8 aft segment was insulated and cured using standard production processes.

  16. Comparative evaluation between anatomic and non-anatomic lateral ligament reconstruction techniques in the ankle joint: A computational study.

    PubMed

    Purevsuren, Tserenchimed; Batbaatar, Myagmarbayar; Khuyagbaatar, Batbayar; Kim, Kyungsoo; Kim, Yoon Hyuk

    2018-03-12

    Biomechanical studies have indicated that the conventional non-anatomic reconstruction techniques for lateral ankle sprain (LAS) tend to restrict subtalar joint motion compared to intact ankle joints. Excessive restriction in subtalar motion may lead to chronic pain, functional difficulties, and development of osteoarthritis. Therefore, various anatomic surgical techniques to reconstruct both the anterior talofibular and calcaneofibular ligaments have been introduced. In this study, ankle joint stability was evaluated using multibody computational ankle joint model to assess two new anatomic reconstruction and three popular non-anatomic reconstruction techniques. An LAS injury, three popular non-anatomic reconstruction models (Watson-Jones, Evans, and Chrisman-Snook), and two common types of anatomic reconstruction models were developed based on the intact ankle model. The stability of ankle in both talocrural and subtalar joint were evaluated under anterior drawer test (150 N anterior force), inversion test (3 Nm inversion moment), internal rotational test (3 Nm internal rotation moment), and the combined loading test (9 Nm inversion and internal moment as well as 1800 N compressive force). Our overall results show that the two anatomic reconstruction techniques were superior to the non-anatomic reconstruction techniques in stabilizing both talocrural and subtalar joints. Restricted subtalar joint motion, which mainly observed in Watson-Jones and Chrisman-Snook techniques, was not shown in the anatomical reconstructions. Evans technique was beneficial for subtalar joint as it does not restrict subtalar motion, though Evans technique was insufficient for restoring talocrural joint inversion. The anatomical reconstruction techniques best recovered ankle stability.

  17. Axisymmetric shell analysis of the Space Shuttle solid rocket booster field joint

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.; Anderson, Melvin S.

    1989-01-01

    The Space Shuttle Challenger (STS 51-L) accident led to an intense investigation of the structural behavior of the solid rocket booster (SRB) tang and clevis field joints. The presence of structural deformations between the clevis inner leg and the tang, substantial enough to prevent the O-ring seals from eliminating hot gas flow through the joints, has emerged as a likely cause of the vehicle failure. This paper presents results of axisymmetric shell analyses that parametrically assess the structural behavior of SRB field joints subjected to quasi-steady-state internal pressure loading for both the original joint flown on mission STS 51-L and the redesigned joint recently flown on the Space Shuttle Discovery. Discussion of axisymmetric shell modeling issues and details is presented and a generic method for simulating contact between adjacent shells of revolution is described. Results are presented that identify the performance trends of the joints for a wide range of joint parameters.

  18. Wormhole Formation in RSRM Nozzle Joint Backfill

    NASA Technical Reports Server (NTRS)

    Stevens, J.

    2000-01-01

    The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and

  19. Expressing the joint moments of drop jumps and sidestep cutting in different reference frames--does it matter?

    PubMed

    Kristianslund, Eirik; Krosshaug, Tron; Mok, Kam-Ming; McLean, Scott; van den Bogert, Antonie J

    2014-01-03

    Joint moments help us understand joint loading and muscle function during movement. However, the interpretation depends on the choice of reference frame, but the different reference frames have not been compared in dynamic, high-impact sporting movements. We have compared the magnitude and the resulting ranking of hip and knee joint moments expressed in the laboratory coordinate system, the local system of the distal segment and projected or decomposed to the Joint Coordinate System (JCS) axes. Hip and knee joint moments of drop jumps and sidestep cutting in 70 elite female handball players were calculated based on recordings from an eight-camera 240 Hz system and two force platforms and expressed with the four methods. The greatest variations in magnitude between conditions were seen for drop jump hip internal rotation (range: 0.31-0.71 Nm/kg) and sidestep cutting knee flexion (2.87-3.39 Nm/kg) and hip internal rotation (0.87-2.36 Nm/kg) and knee internal rotation (0.10-0.40 Nm/kg) moments. The rank correlations were highest between conditions for flexion moments (0.88-1.00) and sidestep cutting abduction moments (0.71-0.98). The rank correlations ranged from 0.64 to 0.73 for drop jump knee abduction moments and between -0.17 and 0.67 for hip and knee internal rotation moments. Expression of joint moments in different reference systems affects the magnitude and ranking of athletes. This lack of consistency may complicate the comparison and combination of results. Projection to the JCS is the only method where joint moments correspond to muscle and ligament loading. More widespread adoption of this convention could facilitate comparison of studies and ease the interpretation of results. © 2013 Elsevier Ltd. All rights reserved.

  20. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

    PubMed Central

    Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung

    2014-01-01

    PURPOSE This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material. PMID:25551010

  1. Risk management in international manned space program operations.

    PubMed

    Seastrom, J W; Peercy, R L; Johnson, G W; Sotnikov, B J; Brukhanov, N

    2004-02-01

    New, innovative joint safety policies and requirements were developed in support of the Shuttle/Mir program, which is the first phase of the International Space Station program. This work has resulted in a joint multinational analysis culminating in joint certification for mission readiness. For these planning and development efforts, each nation's risk programs and individual safety practices had to be integrated into a comprehensive and compatible system that reflects the joint nature of the endeavor. This paper highlights the major incremental steps involved in planning and program integration during development of the Shuttle/Mir program. It traces the transition from early development to operational status and highlights the valuable lessons learned that apply to the International Space Station program (Phase 2). Also examined are external and extraneous factors that affected mission operations and the corresponding solutions to ensure safe and effective Shuttle/Mir missions. c2003 Published by Elsevier Ltd.

  2. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation.

    PubMed

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate.

  3. Management of acute unstable acromioclavicular joint injuries.

    PubMed

    Cisneros, Luis Natera; Reiriz, Juan Sarasquete

    2016-12-01

    Surgical management of acute unstable acromioclavicular joint injuries should be focused on realigning the torn ends of the ligaments to allow for healing potential. The most widely utilized treatment methods incorporate the use of metal hardware, which can alter the biomechanics of the acromioclavicular joint. This leads to a second surgical procedure for hardware removal once the ligaments have healed. Patients with unstable acromioclavicular joint injuries managed with arthroscopy-assisted procedures have shown good and excellent clinical outcomes, without the need for a second operation. These procedures incorporate a coracoclavicular suspension device aimed to function as an internal brace, narrowing the coracoclavicular space thus allowing for healing of the torn coracoclavicular ligaments. The lesser morbidity of a minimally invasive approach and the possibility to diagnose and treat concomitant intraarticular injuries; no obligatory implant removal, and the possibility of having a straight visualization of the inferior aspect of the base of the coracoid (convenient when placing coracoclavicular fixation systems) are the main advantages of the arthroscopic approach over classic open procedures. This article consists on a narrative review of the literature in regard to the management of acute acromioclavicular joint instability.

  4. Development and Implementation of Joint Programs in Laser Ranging and Other Space Geodetic Techniques

    NASA Technical Reports Server (NTRS)

    Pearlman, Michael R.; Carter, David (Technical Monitor)

    2004-01-01

    This progress report discusses the status and progress made in joint international programs including: 1) WEGENER; 2) Arabian Peninsula program; 3) Asia-Pacific Space Geodynamics (APSG) program; 4) the Fourteenth International Workshop on Laser Ranging; 5) the International Laser Ranging Service; and 6) current support for the NASA network.

  5. Time-lapse joint inversion of geophysical data with automatic joint constraints and dynamic attributes

    NASA Astrophysics Data System (ADS)

    Rittgers, J. B.; Revil, A.; Mooney, M. A.; Karaoulis, M.; Wodajo, L.; Hickey, C. J.

    2016-12-01

    Joint inversion and time-lapse inversion techniques of geophysical data are often implemented in an attempt to improve imaging of complex subsurface structures and dynamic processes by minimizing negative effects of random and uncorrelated spatial and temporal noise in the data. We focus on the structural cross-gradient (SCG) approach (enforcing recovered models to exhibit similar spatial structures) in combination with time-lapse inversion constraints applied to surface-based electrical resistivity and seismic traveltime refraction data. The combination of both techniques is justified by the underlying petrophysical models. We investigate the benefits and trade-offs of SCG and time-lapse constraints. Using a synthetic case study, we show that a combined joint time-lapse inversion approach provides an overall improvement in final recovered models. Additionally, we introduce a new approach to reweighting SCG constraints based on an iteratively updated normalized ratio of model sensitivity distributions at each time-step. We refer to the new technique as the Automatic Joint Constraints (AJC) approach. The relevance of the new joint time-lapse inversion process is demonstrated on the synthetic example. Then, these approaches are applied to real time-lapse monitoring field data collected during a quarter-scale earthen embankment induced-piping failure test. The use of time-lapse joint inversion is justified by the fact that a change of porosity drives concomitant changes in seismic velocities (through its effect on the bulk and shear moduli) and resistivities (through its influence upon the formation factor). Combined with the definition of attributes (i.e. specific characteristics) of the evolving target associated with piping, our approach allows localizing the position of the preferential flow path associated with internal erosion. This is not the case using other approaches.

  6. Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method

    NASA Astrophysics Data System (ADS)

    Doaei, Marjan; Tavallali, M. Sadegh

    2018-05-01

    The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.

  7. [A new type sternoclavicular hook plate for unstable sternoclavicular joint dislocation and fracture].

    PubMed

    Zhang, Chuan-Yi; Lin, Lie; Liang, Jun-Bo; Wang, Bin; Chen, Guo-Fu; Chen, Hai-Xiao

    2016-11-25

    To evaluate the therapeutic effect of a new type sternoclavicular hook plate fixation in treating unstable sternoclavicular joint dislocation and fracture. From June 2011 to December 2013, 32 patients with sternoclavicular joint dislocation and fracture were treated with a new type sternoclavicular hook plate fixation, including 24 males and 8 females with an average age of 42 years ranging from 25 to 76 years;12 patients were anterior dislocation, 5 pations were posterior dislocation, 10 patients were internal extremity of clavicle fracture and 5 patients were sternoclavicular joint dislocation combined with fracture. The anterior fracture dislocation of the sternoclavicular joint adopted standard sternoclavicular joint hook plate, and the posterior dislocation was at the distal end of the hook of the steel plate, that is, the front part of the handle of the breast was added with a nut and a gasket to prevent the re-dislocation after operation. The results were evaluated according to Rockwood score. No complication happened in all patients. X-ray and CT showed that the dislocation and fracture of the sternoclavicular joint was well reduced and the plate was on right position. All patients were followed up for 6 to 24 months with an average of 10 months. At 6 to 3 months after operation, the fracture was healing without re-dislocation of the sternoclavicular joint, the medial end of the clavicle anatomical structure were restored, functional satisfaction, in which 9 patients with the swelling around sternoclavicular joint, but no pain and other symptoms. The total Rockwood score was 12.78±1.43; the results were excellent in 24 cases, good in 8 cases. The use of the new type of locking hook plate for the treatment of unstable fracture of the sternoclavicular joint, internal fixation is reliable, high security, easy to operate, to provide a reliable method for the treatment of such trauma.

  8. Joint Technical Coordinating Group on Aircraft Survivability (JTCG/AS). Bibliography of Joint Aircraft Survivability Reports

    DTIC Science & Technology

    2000-07-01

    PMSG ). Report No.: JTCG/AS-99-D-003 Report Classification: UNCLASSIFIED Title: JTCG/AS Bibliography of Joint Aircraft Survivability Reports and...indicates those approved and not approved for funding by the Principal Members Steering Group ( PMSG ). Report No.: Report Classification: JTCG/AS-97-V-010...demonstrated by additional tests conducted at NWSC/Crane (up to Mach 0.8) and Rockwell International wind tunnel (up to Mach 1/9 and 30,000 feet altitude

  9. Influence of a Full-Body Compression Suit on Trunk Positioning and Knee Joint Mechanics During Lateral Movements.

    PubMed

    Mornieux, Guillaume; Weltin, Elmar; Pauls, Monika; Rott, Franz; Gollhofer, Albert

    2017-08-01

    Trunk positioning has been shown to be associated with knee joint loading during athletic tasks, especially changes of direction. The purpose of the present study was to test whether a full-body compression suit (FBCS) would improve trunk positioning and knee joint control during lateral movements. Twelve female athletes performed lateral reactive jumps (LRJ) and unanticipated cuttings with and without the customized FBCS, while 3D kinematics and kinetics were measured. FBCS did not influence trunk positioning during LRJ and led to increased trunk lateral lean during cuttings (P < .001). However, while wearing FBCS, knee joint abduction and internal rotation angles were reduced during LRJ (P < .001 and P = .013, respectively), whereas knee joint moments were comparable during cuttings. FBCS cannot support the trunk segment during unanticipated dynamic movements. But, increased trunk lateral lean during cutting maneuvers was not high enough to elicit increased knee joint moments. On the contrary, knee joint abduction and internal rotation were reduced during LRJ, speaking for a better knee joint alignment with FBCS. Athletes seeking to improve trunk positioning may not benefit from a FBCS.

  10. Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players

    PubMed Central

    Fu, Lin

    2017-01-01

    The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p < 0.05, r = 0.89) and inversion joint moment (p < 0.05, r = 0.54) in the frontal plane as well as greater internal joint rotation moment (p < 0.05, r = 0.28) in the horizontal plane. In contrast, professional badminton players presented a greater knee joint moment in the sagittal (p < 0.05, r = 0.59) and frontal (p < 0.05, r = 0.37) planes, which may be associated with increased knee ligamentous injury risk. To avoid injury, the players need to forcefully extend the knee with internal rotation, strengthen the muscles around the ankle ligament, and maximise joint coordination during training. The injuries recorded and the forces responsible for the injuries seem to have developed during training activity. Training programmes and injury prevention strategies for badminton players should account for these findings to reduce potential injury to the ankle and knee. PMID:28694684

  11. Increasing Running Step Rate Reduces Patellofemoral Joint Forces

    PubMed Central

    Lenhart, Rachel L.; Thelen, Darryl G.; Wille, Christa M.; Chumanov, Elizabeth S.; Heiderscheit, Bryan C.

    2013-01-01

    Purpose Increasing step rate has been shown to elicit changes in joint kinematics and kinetics during running, and has been suggested as a possible rehabilitation strategy for runners with patellofemoral pain. The purpose of this study was to determine how altering step rate affects internal muscle forces and patellofemoral joint loads, and then to determine what kinematic and kinetic factors best predict changes in joint loading. Methods We recorded whole body kinematics of 30 healthy adults running on an instrumented treadmill at three step rate conditions (90%, 100%, and 110% of preferred step rate). We then used a 3D lower extremity musculoskeletal model to estimate muscle, patellar tendon, and patellofemoral joint forces throughout the running gait cycles. Additionally, linear regression analysis allowed us to ascertain the relative influence of limb posture and external loads on patellofemoral joint force. Results Increasing step rate to 110% of preferred reduced peak patellofemoral joint force by 14%. Peak muscle forces were also altered as a result of the increased step rate with hip, knee and ankle extensor forces, and hip abductor forces all reduced in mid-stance. Compared to the 90% step rate condition, there was a concomitant increase in peak rectus femoris and hamstring loads during early and late swing, respectively, at higher step rates. Peak stance phase knee flexion decreased with increasing step rate, and was found to be the most important predictor of the reduction in patellofemoral joint loading. Conclusion Increasing step rate is an effective strategy to reduce patellofemoral joint forces and could be effective in modulating biomechanical factors that can contribute to patellofemoral pain. PMID:23917470

  12. Modification of the Grood and Suntay Joint Coordinate System equations for knee joint flexion.

    PubMed

    Dabirrahmani, Danè; Hogg, Michael

    2017-01-01

    Since its introduction, the Grood and Suntay Joint Coordinate System (JCS) has been embraced by the International Society of Biomechanics (ISB) and been widely used for biomechanical reporting. There is, however, a limitation in its ability to provide correct flexion values over a wide range of clinically relevant flexion angles. This technical note addresses the limitation of the JCS equations and introduces a new set of equations to overcome this problem. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Tibiotalocalcaneal Arthrodesis Nails: A Comparison of Nails With and Without Internal Compression.

    PubMed

    Taylor, James; Lucas, Douglas E; Riley, Aimee; Simpson, G Alex; Philbin, Terrence M

    2016-03-01

    Hindfoot arthrodesis with tibiotalocalcaneal (TTC) intramedullary nails is used commonly when treating ankle and subtalar arthritis and other hindfoot pathology. Adequate compression is paramount to avoid nonunion and fatigue fracture of the hardware. Arthrodesis systems with internal compression have demonstrated superior compression to systems relying on external methods. This study examined the speed of union with TTC fusion nails with internal compression over nails without internal compression. A retrospective review was performed identifying nail type and time to union of the subtalar joint (STJ) and tibiotalar joint (TTJ). A total of 198 patients were included from 2003 to 2011. The median time to STJ fusion without internal compression was 104 days compared to 92 days with internal compression (P = .044). The median time to TTJ fusion without internal compression was 111 days compared to 93 days with internal compression (P = .010). Adjusting for diabetes, there was no significant difference in fusion speed with or without internal compression for the STJ (P = .561) or TTJ (P = .358). Nonunion rates were 24.5% for the STJ and 17.0% for the TTJ with internal compression, and 43.4% for the STJ and 42.1% for the TTJ without internal compression. This difference remained statistically significant after adjusting for diabetes for the TTJ (P = .001) but not for the STJ (P = .194). The intramedullary hindfoot arthrodesis nail was a viable treatment option in degenerative joint disease of the TTC joint. There appeared to be an advantage using systems with internal compression; however, there was no statistically significant difference after controlling for diabetes. Level III, retrospective comparative series. © The Author(s) 2015.

  14. High resolution three-dimensional photoacoustic imaging of human finger joints in vivo

    NASA Astrophysics Data System (ADS)

    Xi, Lei; Jiang, Huabei

    2015-08-01

    We present a method for noninvasively imaging the hand joints using a three-dimensional (3D) photoacoustic imaging (PAI) system. This 3D PAI system utilizes cylindrical scanning in data collection and virtual-detector concept in image reconstruction. The maximum lateral and axial resolutions of the PAI system are 70 μm and 240 μm. The cross-sectional photoacoustic images of a healthy joint clearly exhibited major internal structures including phalanx and tendons, which are not available from the current photoacoustic imaging methods. The in vivo PAI results obtained are comparable with the corresponding 3.0 T MRI images of the finger joint. This study suggests that the proposed method has the potential to be used in early detection of joint diseases such as osteoarthritis.

  15. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    PubMed

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  16. Outcome measures in older persons with acquired joint contractures: a systematic review and content analysis using the ICF (International Classification of Functioning, Disability and Health) as a reference.

    PubMed

    Bartoszek, Gabriele; Fischer, Uli; Müller, Martin; Strobl, Ralf; Grill, Eva; Nadolny, Stephan; Meyer, Gabriele

    2016-02-09

    Joint contractures are a common health problem in older persons with significant impact on activities of daily living. We aimed to retrieve outcome measures applied in studies on older persons with joint contractures and to identify and categorise the concepts contained in these outcome measures using the ICF (International Classification of Functioning, Disability and Health) as a reference. Electronic searches of Medline, EMBASE, CINAHL, Pedro and the Cochrane Library were conducted (1/2002-8/2012). We included studies in the geriatric rehabilitation and nursing home settings with participants aged ≥ 65 years and with acquired joint contractures. Two independent reviewers extracted the outcome measures and transferred them to concepts using predefined conceptual frameworks. Concepts were subsequently linked to the ICF categories. From the 1057 abstracts retrieved, 60 studies met the inclusion criteria. We identified 52 single outcome measures and 24 standardised assessment instruments. A total of 1353 concepts were revealed from the outcome measures; 96.2% could be linked to 50 ICF categories in the 2nd level; 3.8% were not categorised. Fourteen of the 50 categories (28%) belonged to the component Body Functions, 4 (8%) to the component Body Structures, 26 (52%) to the component Activities and Participation, and 6 (12%) to the component Environmental Factors. The ICF is a valuable reference for identifying and quantifying the concepts of outcome measures on joint contractures in older people. The revealed ICF categories remain to be validated in populations with joint contractures in terms of clinical relevance and personal impact.

  17. Behavior of an epoxy-polysulfide adhesive in wood joints exposed to moisture content changes

    Treesearch

    Gordon P. Krueger

    1965-01-01

    The mechanical behavior of a flexible epoxy-resin adhesive system was observed in joints of plywood to lumber. The joints were subjected to internal swelling stresses caused by an increase in moisture content. Previous experimental work at the U.S. Forest Products Laboratory has shown that this adhesive system acts as a strain-absorbing cushion and thus has a...

  18. 26 CFR 1.6013-3 - Treatment of joint return after death of either spouse.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... return after death of either spouse. For purposes of section 21 (relating to change in rates during a... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Treatment of joint return after death of either... death of either spouse, the joint return shall be treated as if the taxable years of both ended on the...

  19. Joint Antarctic School Expedition - An International Collaboration for High School Students and Teachers on Antarctic Science

    NASA Astrophysics Data System (ADS)

    Botella, J.; Warburton, J.; Bartholow, S.; Reed, L. F.

    2014-12-01

    The Joint Antarctic School Expedition (JASE) is an international collaboration program between high school students and teachers from the United States and Chile aimed at providing the skills required for establishing the scientific international collaborations that our globalized world demands, and to develop a new approach for science education. The National Antarctic Programs of Chile and the United States worked together on a pilot program that brought high school students and teachers from both countries to Punta Arenas, Chile, in February 2014. The goals of this project included strengthening the partnership between the two countries, and building relationships between future generations of scientists, while developing the students' awareness of global scientific issues and expanding their knowledge and interest in Antarctica and polar science. A big component of the project involved the sharing by students of the acquired knowledge and experiences with the general public. JASE is based on the successful Chilean Antarctic Science Fair developed by Chile´s Antarctic Research Institute. For 10 years, small groups of Chilean students, each mentored by a teacher, perform experimental or bibliographical Antarctic research. Winning teams are awarded an expedition to the Chilean research station on King George Island. In 2014, the Chileans invited US participation in this program in order to strengthen science ties for upcoming generations. On King George Island, students have hands-on experiences conducting experiments and learning about field research. While the total number of students directly involved in the program is relatively small, the sharing of the experience by students with the general public is a novel approach to science education. Research experiences for students, like JASE, are important as they influence new direction for students in science learning, science interest, and help increase science knowledge. We will share experiences with the

  20. Degenerative joint disease: multiple joint involvement in young and mature dogs.

    PubMed

    Olsewski, J M; Lust, G; Rendano, V T; Summers, B A

    1983-07-01

    Radiologic, pathologic, and ancillary methods were used to determine the occurrence of degenerative joint disease involving multiple joints of immature and adult dogs. Animals were selected for the development of hip joint dysplasia and chronic degenerative joint disease. Of disease-prone dogs, 82% (45 of 55 dogs) had radiologic changes, indicative of hip dysplasia, by 1 year of age. At necropsy, more abnormal joints were identified than by radiographic examination. Among 92 dogs between 3 to 11 months of age that had joint abnormalities, 71% had hip joint involvement; 38%, shoulder joint involvement; 22%, stifle joint involvement; and 40% had multiple joint involvement. Polyarthritis was asymptomatic and unexpected. Radiographic examination of older dogs also revealed evidence of degenerative joint disease in many joints. Multiple joint involvement was substantiated at necropsy of young and mature dogs. A similar pattern of polyarticular osteoarthritis was revealed in a survey (computer search) of necropsy reports from medical case records of 100 adult and elderly dogs. Usually, the joint disease was an incidental observation, unrelated to the clinical disease or to the cause of death. The frequent occurrence of degenerative changes in several joints of dogs aged 6 months to 17 years indicated that osteoarthritis may be progressive in these joints and raises the possibility that systemic factors are involved in the disease process.

  1. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    PubMed

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  2. Reactive arthritis in relation to internal derangements of the temporomandibular joint: a case control study.

    PubMed

    Lund, Bodil; Holmlund, Anders; Wretlind, Bengt; Jalal, Shah; Rosén, Annika

    2015-09-01

    The aim of this study was to find out if reactive arthritis was involved in the aetiology of chronic closed lock of the temporomandibular joint (TMJ) by looking for bacterial antigens in the synovial membrane of the TMJ, and by studying the antibody serology and carriage of human leucocyte antigen (HLA) B27 in patients with chronic closed lock. Patients with reciprocal clicking and healthy subjects acted as controls. We studied a total of 43 consecutive patients, 15 with chronic closed lock, 13 with reciprocal clicking, and 15 healthy controls with no internal derangements of the TMJ. Venous blood samples were collected from all subjects for measurement of concentrations of HLA tissue antigen and serology against Chlamydia trachomatis, Yersinia enterocolitica, Salmonella spp., Campylobacter jejuni, and Mycoplasma pneumoniae. Samples of synovial tissue from patients with closed lock and reciprocal clicking were obtained during discectomy and divided into two pieces, the first of which was tested by strand displacement amplification for the presence of C trachomatis, and the second of which was analysed for the presence of species-specific bacterial DNA using 16s rRNA pan-polymerase chain reaction (PCR). There were no significant differences between the groups in the incidence of antibodies against M pneumoniae, Salmonella spp. or Y enterocolitica. No patient had antibodies towards C trachomatis or C jejuni. We found no bacterial DNA in the synovial fluid from any patient. The HLA B27 antigen was present in 2/15 subjects in both the closed lock and control groups, and none in the reciprocal clicking group. In conclusion, reactive arthritis does not seem to be the mechanism of internal derangement of the TMJ. Copyright © 2015. Published by Elsevier Ltd.

  3. Measurement of varus-valgus and internal-external rotational knee laxities in vivo--Part II: relationship with anterior-posterior and general joint laxity in males and females.

    PubMed

    Shultz, Sandra J; Shimokochi, Yohei; Nguyen, Anh-Dung; Schmitz, Randy J; Beynnon, Bruce D; Perrin, David H

    2007-08-01

    We examined sex differences in general joint laxity (GJL), and anterior-posterior displacement (ANT-POST), varus-valgus rotation (VR-VL), and internal-external rotation (INT-EXT) knee laxities, and determined whether greater ANT and GJL predicted greater VR-VL and INT-EXT. Twenty subjects were measured for GJL, and scored on a scale of 0-9. ANT and POST were measured using a standard knee arthrometer at 133 N. VR-VL and INT-EXT were measured using a custom joint laxity testing device, defined as the angular displacements (deg) of the tibia relative to the femur produced by 0-10 Nm of varus-valgus torques, and 0-5 Nm of internal-external torques, respectively. INT-EXT were measured during both non-weight-bearing (NWB) and weight-bearing (WB = 40% body weight) conditions while VR-VL were measured NWB. All laxity measures were greater for females compared to males except for POST. ANT and GJL positively predicted 62.5% of the variance in VR-VL and 41.8% of the variance in WB INT-EXT. ANT was the sole predictor of INT-EXT in NWB, explaining 42.3% of the variance. These findings suggest that subjects who score higher on clinical measures of GJL and ANT are also likely to have greater VR-VL and INT-EXT knee laxities.

  4. Increase in Total Joint Arthroplasty Projected from 2014 to 2046 in Australia: A Conservative Local Model With International Implications.

    PubMed

    Inacio, Maria C S; Graves, Stephen E; Pratt, Nicole L; Roughead, Elizabeth E; Nemes, Szilard

    2017-08-01

    The incidence of joint arthroplasty is increasing worldwide. International estimates of future demand for joint arthroplasty have used models that propose either an exponential future increase, despite obvious system constraints, or static increases, which do not account for past trends. Country-specific projection estimates that address limitations of past projections are necessary. In Australia, a high-income country with the 7th highest incidence of TKA and 15th highest incidence of THA of the Organization for Economic Cooperation and Development (OECD) countries, the volume of TKAs and THAs increased 198% between 1994 and 2014. To determine the projected incidence and volume of primary TKAs and THAs from 2014 to 2046 in the Australian population older than 40 years. Australian State and Territory Health Department data were used to identify TKAs and THAs performed between 1994 and 1995 and 2013 and 2014. The Australian Bureau of Statistics was the source of the population estimates for the same periods and population-projected estimates until 2046. The incidence rate (IR), 95% CI, and prediction interval (PI) of TKAs and THAs per 100,000 Australian citizens older than 40 years were calculated. Future IRs were estimated using a logistic model, and volume was calculated from projected IR and population. The logistic growth model assumes the existence of an upper limit of the TKA and THA incidences and a growth rate directly related to this incidence. At the beginning, when the observed incidence is much lower than the asymptote, the increase is exponential, but it decreases as it approaches the upper limit. A 66% increase in the IR of primary THAs between 2013 and 2046 is projected for Australia (2013: IR = 307 per 100,000, [95% CI, 262-329 per 100,000] compared with 2046: IR= 510 per 100,000, [95% PI, 98-567 per 100,000]), which translates to a 219% increase in the volume during this period. For TKAs the IR is expected to increase by 26% by 2046 (IR = 575 per

  5. [Staple fixation for the treatment of hamate metacarpal joint injury].

    PubMed

    Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da

    2014-03-01

    To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.

  6. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  7. Effects of hook plate on shoulder function after treatment of acromioclavicular joint dislocation

    PubMed Central

    Chen, Chang-Hong; Dong, Qi-Rong; Zhou, Rong-Kui; Zhen, Hua-Qing; Jiao, Ya-Jun

    2014-01-01

    Introduction: Internal fixation with hook plate has been used to treat acromioclavicular joint dislocation. This study aims to evaluate the effect of its use on shoulder function, to further analyze the contributing factors, and provide a basis for selection and design of improved internal fixation treatment of the acromioclavicular joint dislocation in the future. Methods: A retrospective analysis was performed on patients treated with a hook plate for acromioclavicular joint dislocation in our hospital from January 2010 to February 2013. There were 33 cases in total, including 25 males and 8 females, with mean age of 48.27 ± 8.7 years. There were 29 cases of Rockwood type III acromioclavicular dislocation, 4 cases of type V. The Constant-Murley shoulder function scoring system was used to evaluate the shoulder function recovery status after surgery. Anteroposterior shoulder X-ray was used to assess the position of the hook plate, status of acromioclavicular joint reduction and the occurrence of postoperative complications. Results: According to the Constant-Murley shoulder function scoring system, the average scores were 78 ± 6 points 8 to 12 months after the surgery and before the removal of the hook plate, the average scores were 89 ± 5 minutes two months after the removal of hook plate. Postoperative X-ray imaging showed osteolysis in 10 cases (30.3%), osteoarthritis in six cases (18.1%), osteolysis associated with osteoarthritis in four cases(12.1%), and steel hook broken in one case (3%). Conclusion: The use of hook plate on open reduction and internal fixation of the acromioclavicular joint dislocation had little adverse effect on shoulder function and is an effective method for the treatment of acromioclavicular joint dislocation. Osteoarthritis and osteolysis are the two common complications after hook plate use, which are associated with the impairment of shoulder function. Shoulder function will be improved after removal of the hook plate. PMID

  8. Spacesuit mobility joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1978-01-01

    Joints for use in interconnecting adjacent segments of an hermetically sealed spacesuit which have low torques, low leakage and a high degree of reliability are described. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics. Linkages which restrain the joint from longitudinal distension and a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli are featured. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  9. Space Station Solar Array Joint Repair

    NASA Technical Reports Server (NTRS)

    Loewenthal, Stuart; Allmon, Curtis; Reznik, Carter; McFatter, Justin; Davis, Robert E.

    2015-01-01

    In Oct 2007 the International Space Station (ISS) crew noticed a vibrating camera in the vicinity of Starboard Solar Alpha Rotary Joint (SARJ). It had less than 5 months of run time when the anomaly was observed. This approximately 3.2 meter diameter bearing joint supports solar arrays that power the station critical to its operation. The crew performed an EVA to identify what was causing the vibration. It was discovered that one of the 3 bearing tracks of this unconventional bearing had significant spalling damage. This paper discusses the SARJ's unique bearing design and the vulnerability in its design leading to the observed anomaly. The design of a SARJ vacuum test rig is also described along with the results of a life test that validated the proposed repair should extend the life of the SARJ a minimum of 18 years on-orbit.

  10. From Interactions to Conversations: The Development of Joint Engagement during Early Childhood

    PubMed Central

    Adamson, Lauren B.; Bakeman, Roger; Deckner, Deborah F.; Nelson, P. Brooke

    2013-01-01

    This research traces the development of symbol-infused joint engagement during mother-child interactions into the preschool years. Forty-nine children, who had been previously observed as toddlers (Adamson, Bakeman, & Deckner, 2004), were systematically observed during interactions with their mothers at ages 3½, 4½, and 5½ during activities related to the past and future, internal states, and graphic systems. Although the amount of symbol-infused joint engagement reached a ceiling by 3½, its focus continued to became more complex and its form more balanced. Individual differences in children’s symbol-infused joint engagement were stable across four years. These findings highlight both how joint engagement is transformed as conversational skills develop and how it remains rooted in earlier interactions and supported by caregiver’s actions. PMID:24266591

  11. Joint trajectories for social and physical aggression as predictors of adolescent maladjustment: internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features.

    PubMed

    Underwood, Marion K; Beron, Kurt J; Rosen, Lisa H

    2011-05-01

    This investigation examined the relation between developmental trajectories jointly estimated for social and physical aggression and adjustment problems at age 14. Teachers provided ratings of children's social and physical aggression in Grades 3, 4, 5, 6, and 7 for a sample of 255 children (131 girls, 21% African American, 52% European American, 21% Mexican American). Participants, parents, and teachers completed measures of the adolescent's adjustment to assess internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features. Results showed that membership in a high and rising trajectory group predicted rule-breaking behaviors and borderline personality features. Membership in a high desister group predicted internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features. The findings suggest that although low levels of social and physical aggression may not bode poorly for adjustment, individuals engaging in high levels of social and physical aggression in middle childhood may be at greatest risk for adolescent psychopathology, whether they increase or desist in their aggression through early adolescence.

  12. Joint trajectories for social and physical aggression as predictors of adolescent maladjustment: Internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features

    PubMed Central

    UNDERWOOD, MARION K.; BERON, KURT J.; ROSEN, LISA H.

    2011-01-01

    This investigation examined the relation between developmental trajectories jointly estimated for social and physical aggression and adjustment problems at age 14. Teachers provided ratings of children's social and physical aggression in Grades 3, 4, 5, 6, and 7 for a sample of 255 children (131 girls, 21% African American, 52% European American, 21% Mexican American). Participants, parents, and teachers completed measures of the adolescent's adjustment to assess internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features. Results showed that membership in a high and rising trajectory group predicted rule-breaking behaviors and borderline personality features. Membership in a high desister group predicted internalizing symptoms, rule-breaking behaviors, and borderline and narcissistic personality features. The findings suggest that although low levels of social and physical aggression may not bode poorly for adjustment, individuals engaging in high levels of social and physical aggression in middle childhood may be at greatest risk for adolescent psychopathology, whether they increase or desist in their aggression through early adolescence. PMID:21532919

  13. An evaluation of charity care for tax-exempt hospitals engaging in joint ventures.

    PubMed

    Smith, Pamela C

    2006-01-01

    The study examines whether the level of charity care and financial stability contribute to a nonprofit hospital's motivation for partnering with a for-profit hospital through a joint venture. The Internal Revenue Service (IRS) has heightened its scrutiny of joint ventures within the health care sector. Considering recent calls to investigate the merit of the tax-exempt status of hospitals engaged in joint ventures, this research will assist policy makers in the evaluation of nonprofit hospitals. Constituents will continue to question whether joint ventures contribute to a reduced focus on charitable activities. Results indicate that the propensity to engage in a joint venture significantly increases with increased levels of charity care. Furthermore, nonprofit hospitals with lower profitability are more likely to engage in joint ventures. These results are useful to policy makers when evaluating the level of charity care provided by hospitals seeking alternative strategic alliances. Considering many critics allege hospitals are reducing the provision of charity care to the community, it is imperative for management to be conscious of the impact of joint ventures on the provision of charity care.

  14. Lower extremity joint moments of collegiate soccer players differ between genders during a forward jump.

    PubMed

    Hart, Joseph M; Garrison, J Craig; Palmieri-Smith, Riann; Kerrigan, D Casey; Ingersoll, Christopher D

    2008-05-01

    Lower extremity kinetics while performing a single-leg forward jump landing may help explain gender biased risk for noncontact anterior cruciate ligament injury. Gender comparison of lower extremity joint angles and moments. Static groups comparison. Motion analysis laboratory. 8 male and 8 female varsity, collegiate soccer athletes. 5 single-leg landings from a 100cm forward jump. Peak and initial contact external joint moments and joint angles of the ankle, knee, and hip. At initial heel contact, males exhibited a adduction moment whereas females exhibited a abduction moment at the hip. Females also had significantly less peak hip extension moment and significantly less peak hip internal rotation moment than males had. Females exhibited greater knee adduction and hip internal rotation angles than men did. When decelerating from a forward jump, gender differences exist in forces acting at the hip.

  15. [Clinical applications of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation].

    PubMed

    Chen, Fang-Hu; Zhao, Xiao-Ping; Zheng, Wen-Biao; Zeng, Han-Bing; Ran, Bo; Huang, Hui; Wang, Hai-Bao

    2013-05-01

    To observe the clinical therapeutic effects of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation. From June 2010 to June 2012, 7 patients with sternoclavicular joint dislocation were treated with sternoclavicular hook plate fixation. Among the 7 patients, 5 patients were male and 2 patients were female, and the average age was 42.3 years, ranging from 38 to 54 years. The course of the disease ranged from 1 to 4 weeks. All the patients had trauma history. The clinical manifestations included: obvious swelling and pain of sternoclavicular joint, restricted shoulder joint activity. The sternoclavicular joint dislocation was proved by preoperative X-ray and CT. The postoperative curative effect was evaluated according to Rockwood scoring method. According to Rockwood scoring method, the excellent results obtained in 6 cases, good in 1. There were no complications such as internal fixation loosening or broken, second dislocation, pain in the sternoclavicular joint, and deformity. The function of shoulder joint was good, and the limb activity was free and no pain appeared. The sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation has follow advantages: simple procedure, stable fixation, definite therapeutic effects.

  16. Comparison of structural performance of one- and two-bay rotary joints for truss applications

    NASA Technical Reports Server (NTRS)

    Vail, J. Douglas; Lake, Mark S.

    1991-01-01

    The structural performance of one- and two-bay large-diameter discrete-bearing rotary joints was addressed for application to truss-beam structures such as the Space Station Freedom. Finite element analyses are performed to determine values for rotary joint parameters that give the same bending vibration frequency as the parent truss beam. The structural masses and maximum internal loads of these joints are compared to determine their relative structural efficiency. Results indicate that no significant difference exists in the masse of one- and two-bay rotary joints. This conclusion is reinforced with closed-form calculations of rotary joint structural efficiency in extension. Also, transition truss-member loads are higher in the one-bay rotary joint. However, because of the increased buckling strength of these members, the external load-carrying capability of the one-bay concept is higher than that of the two-bay concept.

  17. Building a Better Trojan Horse: Emerging Army Roles in Joint Urban Operations

    DTIC Science & Technology

    2001-01-01

    Building a Better Trojan Horse : Emerging Army Roles in Joint Urban Operations A Monograph by MAJ Christopher H. Beckert Infantry, U.S. Army School...xx-xx-2000 to xx-xx-2000 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Building a Better Trojan Horse : Emerging Army Roles in Joint...TELEPHONE NUMBER International Area Code Area Code Telephone Number 703 767-9007 DSN 427-9007 2 Abstract BUILDING A BETTER TROJAN HORSE : EMERGING ARMY

  18. Hip rotation angle is associated with frontal plane knee joint mechanics during running.

    PubMed

    Sakaguchi, Masanori; Shimizu, Norifumi; Yanai, Toshimasa; Stefanyshyn, Darren J; Kawakami, Yasuo

    2015-02-01

    Inability to control lower extremity segments in the frontal and transverse planes resulting in large knee abduction angle and increased internal knee abduction impulse has been associated with patellofemoral pain (PFP). However, the influence of hip rotation angles on frontal plane knee joint kinematics and kinetics remains unclear. The purpose of this study was to explore how hip rotation angles are related to frontal plane knee joint kinematics and kinetics during running. Seventy runners participated in this study. Three-dimensional marker positions and ground reaction forces were recorded with an 8-camera motion analysis system and a force plate while subjects ran along a 25-m runway at a speed of 4m/s. Knee abduction, hip rotation and toe-out angles, frontal plane lever arm at the knee, internal knee abduction moment and impulse, ground reaction forces and the medio-lateral distance from the ankle joint center to the center of pressure (AJC-CoP) were quantified. The findings of this study indicate that greater hip external rotation angles were associated with greater toe-out angles, longer AJC-CoP distances, smaller internal knee abduction impulses with shorter frontal plane lever arms and greater knee abduction angles. Thus, there appears to exist a conflict between kinematic and kinetic risk factors of PFP, and hip external rotation angle may be a key factor to control frontal plane knee joint kinematics and kinetics. These results may help provide an appropriate manipulation and/or intervention on running style to reduce the risk of PFP. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. The International Space Station (ISS) Solar Alpha Rotary Joint (SARJ): Materials & Processes (M&P) Lessons Learned for a Large, Rotating Spacecraft Mechanism

    NASA Technical Reports Server (NTRS)

    Golden, Johnny L.

    2016-01-01

    The International Space Station (ISS) utilizes two large rotating mechanisms, the solar alpha rotary joints (SARJs), as part of the solar arrays' alignment system for more efficient power generation. Each SARJ is a 10.3m circumference, nitrided 15-5PH steel race ring of triangular cross-section, with 12 sets of trundle bearing assemblies transferring load across the rolling joint. The SARJ mechanism rotates continuously and slowly - once every orbit, or every 90 minutes. In 2007, the starboard SARJ suffered a lubrication failure, resulting in severe damage (spalling) to one of the race ring surfaces. Extensive effort was conducted to prevent the port SARJ from suffering the same failure, and fortunately that effort was ultimately successful in also recovering the functionality of the starboard SARJ. The M&P engineering function was key in determining the cause of failure and the means for mechanism recovery. From a M&P lessons-learned perspective, observations are made concerning the original SARJ design parameters (boundary conditions), the perceived need for nitriding the race ring, the test conditions employed during qualification, the environmental controls used for the hardware preflight, and the lubrication robustness necessary for complex kinematic mechanisms expecting high-reliability and long-life.

  20. Joint Official Positions of the International Society for Clinical Densitometry and International Osteoporosis Foundation on FRAX(®). Executive Summary of the 2010 Position Development Conference on Interpretation and use of FRAX® in clinical practice.

    PubMed

    Hans, Didier B; Kanis, John A; Baim, Sanford; Bilezikian, John P; Binkley, Neil; Cauley, Jane A; Compston, Juliet E; Cooper, Cyrus; Dawson-Hughes, Bess; El-Hajj Fuleihan, Ghada; Leslie, William D; Lewiecki, E Michael; Luckey, Marjorie M; McCloskey, Eugene V; Papapoulos, Socrates E; Poiana, Catalina; Rizzoli, René

    2011-01-01

    The International Society for Clinical Densitometry (ISCD) and the International Osteoporosis Foundation (IOF) convened the FRAX(®) Position Development Conference (PDC) in Bucharest, Romania, on November 14, 2010, following a two-day joint meeting of the ISCD and IOF on the "Interpretation and Use of FRAX(®) in Clinical Practice." These three days of critical discussion and debate, led by a panel of international experts from the ISCD, IOF and dedicated task forces, have clarified a number of important issues pertaining to the interpretation and implementation of FRAX(®) in clinical practice. The Official Positions resulting from the PDC are intended to enhance the quality and clinical utility of fracture risk assessment worldwide. Since the field of skeletal assessment is still evolving rapidly, some clinically important issues addressed at the PDCs are not associated with robust medical evidence. Accordingly, some Official Positions are based largely on expert opinion. Despite limitations inherent in such a process, the ISCD and IOF believe it is important to provide clinicians and technologists with the best distillation of current knowledge in the discipline of bone densitometry and provide an important focus for the scientific community to consider. This report describes the methodology and results of the ISCD-IOF PDC dedicated to FRAX(®). Copyright © 2011 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  1. Elbow joint fatigue and bench-press training.

    PubMed

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Controlled laboratory study. Motion research laboratory. A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Participants performed bench-press training until fatigued. Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions.

  2. Ambulatory surgery center joint ventures involving tax-exempt entities.

    PubMed

    Becker, S; Pristave, R J; McConnell, W

    1999-01-01

    This article provides an overview of the tax-exempt related issues for ambulatory surgery center joint ventures involving tax-exempt entities. The article analyzes the key points of analysis of the guidance released by the IRS, in particular General Counsel Memorandum 39862, Revenue Ruling 98-15, and Redlands Surgical Services v. Commissioner of the Internal Revenue Service. These key points include whether the venture results in private inurement to insiders and whether the venture furthers the charitable purposes of the tax-exempt entity. The article also provides practical guidance to analyze the documents and structure of the joint venture to ensure compliance with the IRS guidance. These practical considerations include, among other things, whether the charitable purposes of the tax-exempt entity are clearly expressed in the documents and whether the tax-exempt entity has sufficient control over the joint venture to ensure the charitable purposes are being adhered to.

  3. Brief communication: Hip joint mobility in free-ranging rhesus macaques

    PubMed Central

    Hammond, Ashley S.; Johnson, Victoria P.; Higham, James P.

    2016-01-01

    Objectives We aimed to test for differences in hip joint range of motion (ROM) between captive and free-ranging rhesus macaques (Macaca mulatta), particularly for hip joint abduction, which previous studies of captive macaques have found to be lower than predicted. Materials and Methods Hip ROM was assessed following standard joint measurement methodology in anesthetized adult free-ranging rhesus macaques (n=39) from Cayo Santiago, and compared to published ROM data from captive rhesus macaques (n=16) (Hammond 2014a, American Journal of Physical Anthropology). Significant differences between populations were detected using one-way analysis of variance (p<0.05). Results In a sample of pooled sexes and ages, free-ranging macaques are capable of increased hip abduction, flexion, and internal rotation compared to captive individuals. These differences in joint excursion resulted in free-ranging individuals having significantly increased ROM for hip adduction-abduction, rotation, flexion-extension, and the distance spanned by the knee during hip abduction. When looking at data for a smaller sample of age-matched males, fewer ROM differences are significant, but free-ranging males have significantly increased hip abduction, internal rotation, range of flexion-extension, and distance spanned by the knee during hip abduction compared to captive males of similar age. Discussion Our results suggest that a spatially restrictive environment results in decreased hip mobility in cage-confined animals and ultimately limits the potential limb postures in captive macaques. These results have implications for selection of animal samples in model validation studies, as well as laboratory animal husbandry practices. PMID:27731892

  4. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    PubMed

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures

    NASA Technical Reports Server (NTRS)

    Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini,Benjamin; Young, Daniel

    1990-01-01

    A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

  6. [A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].

    PubMed

    Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi

    2012-06-01

    To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.

  7. Height-Error Analysis for the FAA-Air Force Replacement Radar Program (FARR)

    DTIC Science & Technology

    1991-08-01

    7719 Figure 1-7 CLIMATOLOGY ERRORS BY MONWTH PERCENT FREQUENCY TABLE OF ERROR BY MONTH ERROR MONTH Col Pc IJAl IFEB )MA IA R IAY JJ’N IJUL JAUG (SEP...MONTH Col Pct IJAN IFEB IMPJ JAPR 1 MM IJUN IJUL JAUG ISEP J--T IN~ IDEC I Total ----- -- - - --------------------------.. . -.. 4...MONTH ERROR MONTH Col Pct IJAN IFEB IM4AR IAPR IMAY jJum IJU JAUG ISEP JOCT IN JDEC I Total . .- 4

  8. Playing Detective: Reconstructing Software Architecture from Available Evidence

    DTIC Science & Technology

    1997-10-01

    information • PostgreSQL (based on POSTGRES [Stonebraker 90]) for model storage • IAPR [Kazman 96c], RMTool [Murphy 95], and Perl for analysis and...720-741. Stonebraker, M.; Rowe, L; & Hirohama, M. ’The Implementation of POSTGRES ." IEEE Transactions on Knowledge and Data Engineering 2,1 (March...Engineering 19,7 (July 1993): 720-741. Stonebraker, M.; Rowe, L; & Hirohama, M. "The Implementation of POSTGRES ." IEEE Transactions on Knowledge and

  9. International Space Station (ISS)

    NASA Image and Video Library

    2001-03-01

    Backdropped against water and clouds, the International Space Station was separated from the Space Shuttle Discovery after several days of joint activities and an important crew exchange. This photograph was taken by one of the crew of this mission from the aft flight deck of Discovery.

  10. A review of NASA international programs

    NASA Technical Reports Server (NTRS)

    1979-01-01

    A synoptic overview of NASA's international activities to January 1979 is presented. The cooperating countries and international organizations are identified. Topics covered include (1) cooperative arrangements for ground-based, spaceborne, airborne, rocket-borne, and balloon-borne ventures, joint development, and aeronautical R & D; (2) reimbursable launchings; (3) tracking and data acquisition; and (4) personnel exchanges. International participation in NASA's Earth resources investigations is summarized in the appendix. A list of automatic picture transmission stations is included.

  11. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Towards Scalable Strain Gauge-Based Joint Torque Sensors

    PubMed Central

    D’Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G.; Cuschieri, Alfred

    2017-01-01

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR). PMID:28820446

  13. Towards Scalable Strain Gauge-Based Joint Torque Sensors.

    PubMed

    Khan, Hamza; D'Imperio, Mariapaola; Cannella, Ferdinando; Caldwell, Darwin G; Cuschieri, Alfred; Semini, Claudio

    2017-08-18

    During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS) , the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot- MiniHyQ . This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR).

  14. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  15. [Research progress of three-dimensional printing technique in joint surgery].

    PubMed

    Wang, Fuyou; Ren, Xiang; Yang, Liu

    2014-03-01

    To summarize the application status of three-dimensional (3-D) printing technique in joint surgery and look forward to the future research directions. The recent original articles about the application and research of 3-D printing technique in joint surgery were extensively reviewed and analyzed. In clinical applications, 3-D printing technique can provide "tailored" treatment and custom implants for patients, which helps doctors to perform the complex operations easier and more safely; in fundamental research, tissue engineered scaffolds with desirable external shape and internal organization are easily fabricated with 3-D printing technique, which can meet the demand of cell adherence and proliferation. Even more, cells may be deposited with the biomaterials during the printing. With the development of medical imaging, digital medicine and new materials, 3-D printing technique will have a wider range of applications in joint surgery.

  16. Understanding the Other through International Professional Teaching Experiences

    ERIC Educational Resources Information Center

    Buchanan, John

    2017-01-01

    Universities encourage students to undertake international professional experiences so they can add international and intercultural dimensions to their development. This paper adopts a theoretical backdrop of neocolonialism to investigate the experiences of four Australian pre-service teachers who jointly undertook an IPE in Bandung, Indonesia.…

  17. Shoulder joint luxation in large animals: 14 cases (1976-1997).

    PubMed

    Semevolos, S A; Nixon, A J; Goodrich, L R; Ducharme, N G

    1998-12-01

    To determine clinical and radiographic findings in and treatment and outcome of large animals with shoulder joint luxations. Retrospective study. 5 horses, 3 goats, 1 calf, 1 sheep, 1 Himalayan tahr, 1 pot-bellied pig, 1 reindeer, and 1 white-tailed deer. Medical records and radiographs were reviewed to determine signalment, history, physical examination findings, type of luxation, treatment, and outcome. Owners and referring veterinarians were contracted for follow-up information. Goats, sexually intact males, and animals < 1 year old were overrepresented, compared with the general hospital population during the study period. Closed reduction was attempted in 3 animals and was successful in 1. Open reduction and internal stabilization was attempted in 4 animals, including 1 in which closed reduction was unsuccessful. Long-term stabilization of the joint was achieved in 3 animals, but overall results were poor because of osteoarthritis and chronic lameness. Three animals were not treated, and 5 were euthanatized because of a poor prognosis. Large animals with shoulder joint luxation and concurrent fractures had a poorer prognosis than did those with shoulder joint luxation alone.

  18. [Arthroscopic therapy of ankle joint impingement syndrome after operation of ankle joint fracture dislocation].

    PubMed

    Feng, Zhibin; Mi, Kun; Wei, Renzhi; Liu, Wu; Wang, Bin

    2011-07-01

    To study the operative procedure and the effectiveness of arthroscopic therapy for ankle joint impingement syndrome after operation of ankle joint fracture dislocation. Between March 2008 and April 2010, 38 patients with ankle joint impingement syndrome after operation of ankle joint fracture dislocation were treated. Among them, there were 28 males and 10 females with an average age of 28 years (range, 18 to 42 years). The time from internal fixation to admission was 12-16 months (mean, 13.8 months). There were pressing pain in anterolateral and anterior ankle. The dorsal extension ranged from -20 to -5 degrees (mean, -10.6 degrees), and the palmar flexion was 30-40 degrees (mean, 35.5 degrees). The total score was 48.32 +/- 9.24 and the pain score was 7.26 +/- 1.22 before operation according to American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score system. The X-ray films showed osteophyte formation in anterior tibia and talus; MRI showed cartilage injury in 22 cases. Arthroscopic intervention included removing osteophytes, debriding fabric scars and synovial membrane tissues, and removing osteochondral fragments. Arthroscopic microfracture technique was used in 22 patients with cartilage injury. All incisions healed primarily. Thirty-eight cases were followed up 10-26 months (mean, 16 months). At last follow-up, 26 patients had normal range of motion (ROM); the dorsal extension was 15-25 degrees (mean, 19.6 degrees) and the palmar flexion was 35-45 degrees (mean, 40.7 degrees). Eight patients had mild limited ROM; the dorsal extension was 5-15 degrees (mean, 7.2 degrees) and the palmar flexion was 35-45 degrees (mean, 39.5 degrees). Four patients had mild limited ROM and pain in posterior portion of the ankle after a long walking (3-4 hours); the dorsal extension was 0-5 degrees (mean, 2.6 degrees) and the palmar flexion was 35-40 degrees (mean, 37.5 degrees). The total score was 89.45 +/- 9.55 and the pain score was 1.42 +/- 1.26 after

  19. Are the Kinematics of the Knee Joint Altered during the Loading Response Phase of Gait in Individuals with Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-ray Study

    PubMed Central

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B.; Klatt, Brian A.; Fitzgerald, G. Kelley

    2011-01-01

    Background Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional declines in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Methods Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Findings Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P < 0.01), while the total abduction/adduction range of motion was increased (P < 0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P < 0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. Interpretations The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. PMID:22071429

  20. [Repair and reconstruction for severe fracture and dislocation of ankle joint].

    PubMed

    Yin, Qingwei; Jiang, Yi; Xiao, Lianping; Li, Xiaodong; Fu, Jiaxin; Tian, Yonggang; Han, Liqiang; Liu, Zhi

    2008-06-01

    To summarize the technique and effect of the therapy for severe fracture and dislocation of ankle joint by operation. From March 2003 to February 2006, 76 cases were treated with primary open restoration and internal fixation for dislocated ankle joint fracture, with 47 males and 29 females, with the average age of 36.4 years (ranging from 18 years to 65 years). According to AO criterion, these fresh fractures were classified into 13 cases for type C3-1, 45 cases for type C3-2 and 18 cases for type C3-3. Based on the Gustilo-Anderson standard, 23 open fractures were classified into 17 cases for type II and 6 cases for type III A. The operation was delayed from 1 hours to 24 hours after the injury. All incisions healed at the first stage except 4 cases which delayed union because of simple infection by revision with ointment. A total of 72 cases were followed up, with the average time of 18.5 months (from 12 months to 35 months). The time of bone union was from 12 weeks to 24 weeks. The screws of fixation for lower tibia-fibula joint were found to be ruptured in 2 cases when further consultation was performed in the 16th and 20th week after the operation, respectively, and were broken within 1 year after the operation. These screws were taken out 12 weeks postoperative in 28 cases, while the whole internal fixations of the rest cases were taken out 1 year after the operation. The postoperative function of malleolus extended from 21.7 degrees to 26.8 degrees and flection from 38.5 degrees to 44.7 degrees. Assessed by the American Orthopaedic Foot and Ankle Society Clinical Rating Scales, 23 cases were excellent, 36 good, 13 fair, and the choiceness rate reached 81.94%. These procedures, together with reduction by twist after hospital, open and internal fixation in time, and parenchyma managed with internal fixation, are important to attain satisfactory effect for the treatment of severe fracture and dislocation of ankle joint.

  1. Joint Instability and Osteoarthritis

    PubMed Central

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA. PMID:25741184

  2. Joint instability and osteoarthritis.

    PubMed

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA.

  3. Effects of footwear on three-dimensional tibiotalar and subtalar joint motion during running.

    PubMed

    Peltz, Cathryn D; Haladik, Jeffrey A; Hoffman, Scott E; McDonald, Michael; Ramo, Nicole L; Divine, George; Nurse, Matthew; Bey, Michael J

    2014-08-22

    Running is a popular form of recreation, but injuries are common and may be associated with abnormal joint motion. The objective of this study was to determine the effect of three footwear conditions - barefoot (BF), an ultraflexible training shoe (FREE), and a motion control shoe (MC) - on 3D foot and ankle motion. Dynamic, biplane radiographic images were acquired from 12 runners during overground running. 3D rotations of the tibiotalar and subtalar joints were quantified in terms of plantarflexion/dorsiflexion (PF/DF), inversion/eversion (IN/EV) and internal/external rotation (IR/ER). Across the early stance phase (defined as footstrike to heel-off), BF running demonstrated greater tibiotalar joint range of motion for PF/DF (28.2 ± 8.3°) and IR/ER (7.0 ± 1.4°) than the shod conditions (FREE: PF/DF=15.1 ± 5.9°, IR/ER=4.8 ± 2.1°; MC: PF/DF=15.0 ± 6.2°, IR/ER=4.3 ± 0.7°). Also at the tibiotalar joint, BF running resulted in a position significantly more plantarflexed (BF: 2.0 ± 12.5°, FREE: 15.7 ± 12.2°, MC: 16.5 ± 9.3°) and internally rotated (BF: 12.9 ± 4.5°, FREE: 10.7 ± 4.3°, MC: 10.6 ± 3.9°) at footstrike compared to both shod conditions. No differences were detected between the shod conditions at any point in the early stance phase at the tibiotalar joint. The MC condition demonstrated significant differences compared to FREE at several points throughout the early stance phase at the subtalar joint, with the greatest differences seen at 30% in PF/DF (MC -1.4 ± 8.8°: FREE: -0.5 ± 9.0°), IN/EV (MC -8.1 ± 5.7°: FREE -6.3 ± 5.5°) and IR/ER (MC -9.5 ± 5.3°: FREE: -8.7 ± 5.2°). These findings indicate that footwear has subtle effects on joint motion mainly between BF and shod conditions at the tibiotalar joint and between shod conditions at the subtalar joint. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Structural Performance of Inconel 625 Superalloy Brazed Joints

    NASA Astrophysics Data System (ADS)

    Chen, Jianqiang; Demers, Vincent; Cadotte, Eve-Line; Turner, Daniel; Bocher, Philippe

    2017-02-01

    The purpose of this work was to investigate tensile and fatigue behaviors of Inconel 625 superalloy brazed joints after transient liquid-phase bonding process. Brazing was performed in a vacuum furnace using a nickel-based filler metal in a form of paste to join wrought Inconel 625 plates. Mechanical tests were carried out on single-lap joints under various lap distance-to-thickness ratios. The fatigue crack initiation and crack growth modes were examined via metallographic analysis, and the effect of local stress on fatigue life was assessed by finite element simulations. The fatigue results show that fatigue strength and endurance limit increase with overlap distance, leading to a relatively large scatter of results. Fatigue cracks nucleated in the high-stressed region of the weld fillets from brittle eutectic phases or from internal brazing cavities. The present work proposes to rationalize the results by using the local stress at the brazing fillet. When using this local stress, all fatigue-obtained results find themselves on a single S- N curve, providing a design curve for any joint configuration in fatigue solicitation.

  5. Third International Satellite Direct Broadcast Services User's Conference

    NASA Technical Reports Server (NTRS)

    Kamowski, J.; Vermillion, C.

    1988-01-01

    A workshop titled, The Third International Satellite Direct Broadcast Services User's Conference, jointly sponsored by NASA and NOAA/NESDIS was scheduled to be held June 20 to 24, 1988, at the International Hotel located at the Baltimore-Washington Airport. Details concerning the organizing of the conference are given.

  6. Interpretation and use of FRAX in clinical practice - position paper of the International Osteoporosis Foundation and the International Society for Clinical Densitometry

    USDA-ARS?s Scientific Manuscript database

    The International Osteoporosis Foundation (IOF) and the International Society for Clinical Densitometry (ISCD) appointed a joint Task Force to develop resource documents in order to make recommendations on how to improve FRAX and better inform clinicians who use FRAX. The Task Force met in November...

  7. International Workshop on Linear Colliders 2010

    ScienceCinema

    Lebrun, Ph.

    2018-06-20

    IWLC2010 International Workshop on Linear Colliders 2010ECFA-CLIC-ILC joint meeting: Monday 18 October - Friday 22 October 2010Venue: CERN and CICG (International Conference Centre Geneva, Switzerland). This year, the International Workshop on Linear Colliders organized by the European Committee for Future Accelerators (ECFA) will study the physics, detectors and accelerator complex of a linear collider covering both CLIC and ILC options. Contact Workshop Secretariat  IWLC2010 is hosted by CERN.

  8. International Workshop on Linear Colliders 2010

    ScienceCinema

    Yamada, Sakue

    2018-05-24

    IWLC2010 International Workshop on Linear Colliders 2010ECFA-CLIC-ILC joint meeting: Monday 18 October - Friday 22 October 2010Venue: CERN and CICG (International Conference Centre Geneva, Switzerland) This year, the International Workshop on Linear Colliders organized by the European Committee for Future Accelerators (ECFA) will study the physics, detectors and accelerator complex of a linear collider covering both CLIC and ILC options. Contact Workshop Secretariat  IWLC2010 is hosted by CERN

  9. The payload canister leaves the O&C with the Joint Airlock Module inside

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The payload canister, with the Joint Airlock Module inside, backs out of the Operations and Checkout Building for a short trip to the Space Station Processing Facility. There the module will undergo more preflight processing for the STS-104 mission scheduled for launch aboard Space Shuttle Atlantis May 17, 2001. The Joint Airlock Module is the gateway from which crew members aboard the International Space Station will enter and exit the 470-ton orbiting research facility.

  10. Joint water-fat separation and deblurring for spiral imaging.

    PubMed

    Wang, Dinghui; Zwart, Nicholas R; Pipe, James G

    2018-06-01

    Most previous approaches to spiral Dixon water-fat imaging perform the water-fat separation and deblurring sequentially based on the assumption that the phase accumulation and blurring as a result of off-resonance are separable. This condition can easily be violated in regions where the B 0 inhomogeneity varies rapidly. The goal of this work is to present a novel joint water-fat separation and deblurring method for spiral imaging. The proposed approach is based on a more accurate signal model that takes into account the phase accumulation and blurring simultaneously. A conjugate gradient method is used in the image domain to reconstruct the deblurred water and fat iteratively. Spatially varying convolutions with a local convergence criterion are used to reduce the computational demand. Both simulation and high-resolution brain imaging have demonstrated that the proposed joint method consistently improves the quality of reconstructed water and fat images compared with the sequential approach, especially in regions where the field inhomogeneity changes rapidly in space. The loss of signal-to-noise-ratio as a result of deblurring is minor at optimal echo times. High-quality water-fat spiral imaging can be achieved with the proposed joint approach, provided that an accurate field map of B 0 inhomogeneity is available. Magn Reson Med 79:3218-3228, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Design/analysis of the JWST ISIM bonded joints for survivability at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini, Benjamin; Young, Daniel

    2005-08-01

    A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite adhesively bonded joints at the cryogenic temperature of 30K (-405°F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to hybrid composite tubes (75mm square) made with M55J/954-6 and T300/954-6 prepregs. Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently, the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

  12. The hindlimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L; Colborne, G R

    2001-01-01

    The objective of the study was to describe net joint moments and joint powers in the equine hindlimb during walking. The subjects were 5 sound horses. Kinematic and force data were collected synchronously and combined with morphometric information to determine net joint moments at each hindlimb joint throughout stance and swing. The results showed that the net joint moment was on the caudal/plantar side of all hindlimb joints at the start of stance when the limb was being actively retracted. It moved to the cranial/dorsal side around 24% stride at the hip and stifle and in terminal stance at the more distal joints. It remained on the cranial/dorsal side of all joints during the first half of swing to provide active limb protraction, then moved to the caudal/plantar aspect to reverse the direction of limb motion prior to ground contact. The hip joint was the main source of energy generation throughout the stride. It was assisted by the tarsal joint in both stance and swing phases and by the fetlock joint during the stance phase. The coffin joint acted as an energy damper during stance, whereas the stifle joint absorbed almost equal amounts of energy in the stance and swing phases. The coffin and fetlock joints absorbed energy as the limb was protracted and retracted during the swing phase, suggesting that their movements were driven by inertial forces. Future studies will apply these findings to detect changes in the energy profiles due to specific soft tissue injuries.

  13. Curricular Joint Ventures: A New Chapter in US Cross-Border Education?

    ERIC Educational Resources Information Center

    Eckel, Peter D.; Green, Madeleine F.; Affolter-Caine, Britany

    2004-01-01

    For universities in industrialized nations such as the United States, globalization poses relatively little threat and offers many benefits. This article identifies and describes one trend emerging from globalization--how American colleges and universities are leveraging their curricula internationally through joint ventures between universities…

  14. International Space Station (ISS)

    NASA Image and Video Library

    2006-09-17

    This view of the International Space Station, back dropped against the blackness of space, was taken shortly after the Space Shuttle Atlantis undocked from the orbital outpost at 7:50 a.m. CDT during the STS-115 mission. The unlinking completed after six days, two hours and two minutes of joint operations of the installation of the P3/P4 truss. The new 17 ton truss included batteries, electronics, a giant rotating joint, and sported a second pair of 240-foot solar wings. The new solar arrays will eventually double the onboard power of the Station when their electrical systems are brought online during the next shuttle flight, STS-116.

  15. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  16. Spacesuit mobility knee joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1979-01-01

    Pressure suit mobility joints are for use in interconnecting adjacent segments of an hermetically sealed spacesuit in which low torques, low leakage and a high degree of reliability are required. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics and includes linkages which restrain the joint from longitudinal distension and includes a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  17. Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

    PubMed

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B; Klatt, Brian A; Fitzgerald, G Kelley

    2012-05-01

    Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional decline in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P<0.01), while the total abduction/adduction range of motion was increased (P<0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P<0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Joint Enabling Capabilities Command

    Science.gov Websites

    Executive Director Chief of Staff Joint Planning Support Element Joint Communications Support Element mission Joint Enabling Capabilities Command provides decisive joint communications, planning and public and responsive support for joint communications, planning and public affairs. Priorities * Deliver

  19. International Space Station (ISS)

    NASA Image and Video Library

    2001-03-01

    One of the astronauts aboard the Space Shuttle Discovery took this photograph, from the aft flight deck of the Discovery, of the International Space Station (ISS) in orbit. The photo was taken after separation of the orbiter Discovery from the ISS after several days of joint activities and an important crew exchange.

  20. Mechanical stability of the subtalar joint after lateral ligament sectioning and ankle brace application: a biomechanical experimental study.

    PubMed

    Kamiya, Tomoaki; Kura, Hideji; Suzuki, Daisuke; Uchiyama, Eiichi; Fujimiya, Mineko; Yamashita, Toshihiko

    2009-12-01

    The roles of each ligament supporting the subtalar joint have not been clarified despite several biomechanical studies. The effects of ankle braces on subtalar instability have not been shown. The ankle brace has a partial effect on restricting excessive motion of the subtalar joint. Controlled laboratory study. Ten normal fresh-frozen cadaveric specimens were used. The angular motions of the talus were measured via a magnetic tracking system. The specimens were tested while inversion and eversion forces, as well as internal and external rotation torques, were applied. The calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament were sectioned sequentially, and the roles of each ligament, as well as the stabilizing effects of the ankle brace, were examined. Complete sectioning of the ligaments increased the angle between the talus and calcaneus in the frontal plane to 51.7 degrees + or - 11.8 degrees compared with 35.7 degrees + or - 6.0 degrees in the intact state when inversion force was applied. There was a statistically significant difference in the angles between complete sectioning of the ligaments and after application of the brace (34.1 degrees + or - 7.3 degrees ) when inversion force was applied. On the other hand, significant differences in subtalar rotation were not found between complete sectioning of the ligaments and application of the brace when internal and external rotational torques were applied. The ankle brace limited inversion of the subtalar joint, but it did not restrict motion after application of internal or external rotational torques. In cases of severe ankle sprains involving the calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament injuries, application of an ankle brace might be less effective in limiting internal-external rotational instabilities than in cases of inversion instabilities in the subtalar joint. An improvement in the design of the brace is needed to restore

  1. Determination of a safe INR for joint injections in patients taking warfarin.

    PubMed

    Bashir, M A; Ray, R; Sarda, P; Li, S; Corbett, S

    2015-11-01

    With an increase in life expectancy in 'developed' countries, the number of elderly patients receiving joint injections for arthritis is increasing. There are legitimate concerns about an increased risk of thromboembolism if anticoagulation is stopped or reversed for such an injection. Despite being a common dilemma, the literature on this issue is scarce. We undertook 2,084 joint injections of the knee and shoulder in 1,714 patients between August 2008 and December 2013. Within this cohort, we noted 41 patients who were taking warfarin and followed them immediately after joint injection in the clinic or radiology department, looking carefully for complications. Then, we sought clinical follow-up, correspondence, and imaging evidence for 4 weeks, looking for complications from these joint injections. We recorded International Normalised Ratio (INR) values before injection. No complications were associated with the procedure after any joint injection. The radiologists who undertook ultrasound-guided injections to shoulders re-scanned the joints looking for haemarthroses: they found none. A similar outcome was noted clinically after injections in the outpatient setting. With a mean INR of 2.77 (range, 1.7-5.5) and a maximum INR within this group of 5.5, joint injections to the shoulder and knee can be undertaken safely in primary or secondary care settings despite the patient taking warfarin.

  2. Elbow Joint Fatigue and Bench-Press Training

    PubMed Central

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Context: Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. Objective: To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Design: Controlled laboratory study. Setting: Motion research laboratory. Patients or Other Participants: A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Intervention(s): Participants performed bench-press training until fatigued. Main Outcome Measure(s): Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. Results: We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. Conclusions: The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should

  3. MP Joint Arthritis

    MedlinePlus

    ... is extensive and severe, joint replacement or joint fusion are effective surgical options. Learn more about joint ... the tabs at the top (Video, Articles/WEB, Images, JHS, Products/Vendors), or the filters on the ...

  4. Expanding NASA and Roscosmos Scientific Collaboration on the International Space Station

    NASA Technical Reports Server (NTRS)

    Hasbrook, Pete

    2016-01-01

    The International Space Station (ISS) is a world-class laboratory orbiting in space. NASA and Roscosmos have developed a strong relationship through the ISS Program Partnership, working together and with the other ISS Partners for more than twenty years. Since 2013, based on a framework agreement between the Program Managers, NASA and Roscosmos are building a joint program of collaborative research on ISS. This international collaboration is developed and implemented in phases. Initially, members of the ISS Program Science Forum from NASA and TsNIIMash (representing Roscosmos) identified the first set of NASA experiments that could be implemented in the "near term". The experiments represented the research categories of Technology Demonstration, Microbiology, and Education. Through these experiments, the teams from the "program" and "operations" communities learned to work together to identify collaboration opportunities, establish agreements, and jointly plan and execute the experiments. The first joint scientific activity on ISS occurred in January 2014, and implementation of these joint experiments continues through present ISS operations. NASA and TsNIIMash have proceeded to develop "medium term" collaborations, where scientists join together to improve already-proposed experiments. A major success is the joint One-Year Mission on ISS, with astronaut Scott Kelly and cosmonaut Mikhail Kornienko, who returned from ISS in March, 2016. The teams from the NASA Human Research Program and the RAS Institute for Biomedical Problems built on their considerable experience to design joint experiments, learn to work with each other's protocols and processes, and share medical and research data. New collaborations are being developed between American and Russian scientists in complex fluids, robotics, rodent research and space biology, and additional human research. Collaborations are also being developed in Earth Remote Sensing, where scientists will share data from imaging

  5. PREFACE: Theory of Fusion Plasmas, 13th Joint Varenna-Lausanne International Workshop (2012)

    NASA Astrophysics Data System (ADS)

    Garbet, Xavier; Sauter, Olivier

    2012-12-01

    The 2012 joint Varenna-Lausanne international workshop on the theory of fusion plasmas has been very fruitful. A broad variety of topics were addressed, as usual covering turbulence, MHD, edge physic, RF wave heating and a taste of astrophysics. Moreover the scope of the meeting was extended this year to include the physics of materials and diagnostics for burning plasmas. This evolution reflects the complexity of problems at hand in fusion, in particular in the context of ITER construction. Long-standing problems without immediate consequences have sometimes become an urgent matter in that context. One may quote for instance the choice of plasma facing components or the design of control systems. Another characteristic of the meeting is the interplay between various domains of plasma physics. For instance MHD modes are now currently investigated with gyrokinetic codes, kinetic effects are more and more included in MHD stability analysis, and turbulence is now accounted for in wave propagation problems. This is the proof of cross-fertilization and it is certainly a healthy sign in our community. Finally introducing some novelty in the programme does not prevent us from respecting the traditions of the meeting. As usual a good deal of the presentations were dedicated to numerical simulations. Combining advanced numerical techniques with elaborated analytical theory is certainly a trademark of the Varenna-Lausanne conference, which was respected again this year. The quality and size of the scientific production is illustrated by the 26 papers which appear in the present volume of Journal of Physics: Conference Series, all refereed. We would also like to mention another set of 20 papers to be published in Plasma Physics and Controlled Fusion. We hope the readers will enjoy this special issue of JPCS and the one to come in PPCF. Xavier Garbet and Olivier Sauter October 26, 2012

  6. Associations between joint attention and language in autism spectrum disorder and typical development: A systematic review and meta-regression analysis.

    PubMed

    Bottema-Beutel, Kristen

    2016-10-01

    Using a structured literature search and meta-regression procedures, this study sought to determine whether associations between joint attention and language are moderated by group (autism spectrum disorder [ASD] vs. typical development [TD]), joint attention type (responding to joint attention [RJA] vs. other), and other study design features and participant characteristics. Studies were located using database searches, hand searches, and electronic requests for data from experts in the field. This resulted in 71 reports or datasets and 605 effect sizes, representing 1,859 participants with ASD and 1,835 TD participants. Meta-regression was used to answer research questions regarding potential moderators of the effect sizes of interest, which were Pearson's r values quantifying the association between joint attention and language variables. In the final models, conducted separately for each language variable, effect sizes were significantly higher for the ASD group as compared to the TD group, and for RJA as compared to non-RJA joint attention types. Approximate mental age trended toward significance for the expressive language model. Joint attention may be more tightly tied to language in children with ASD as compared to TD children because TD children exhibit joint attention at sufficient thresholds so that language development becomes untethered to variations in joint attention. Conversely, children with ASD who exhibit deficits in joint attention develop language contingent upon their joint attention abilities. Because RJA was more strongly related to language than other types of joint attention, future research should involve careful consideration of the operationalization and measurement of joint attention constructs. Autism Res 2016, 9: 1021-1035. © 2016 International Society for Autism Research, Wiley Periodicals, Inc. © 2016 International Society for Autism Research, Wiley Periodicals, Inc.

  7. Effect of Direct Ligament Repair and Tenodesis Reconstruction on Simulated Subtalar Joint Instability.

    PubMed

    Choisne, Julie; Hoch, Matthew C; Alexander, Ian; Ringleb, Stacie I

    2017-03-01

    Subtalar instability is associated with up to 80% of patients presenting with chronic ankle instability but is often not considered in the diagnosis or treatment. Operative procedures to repair ankle instability have shown good clinical results, but the effects of these reconstruction procedures on isolated subtalar instability are not well understood. The goal of this study was to investigate the effect of the Gould modification of the Broström procedure and a new tenodesis reconstruction procedure on ankle and subtalar joint kinematics after simulating a subtalar injury. Kinematic data were collected on 7 cadaveric ankles during inversion through the range of ankle flexion and during internal rotation. Testing was performed on the intact foot; after sectioning the calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament; after the Gould modification of the Broström procedure was performed; and after tenodesis was performed and sutures from the Gould modification removed. The Gould modification of the Broström procedure significantly decreased subtalar and ankle inversion motion and subtalar internal rotation compared to the unstable condition. The tenodesis method restricted internal rotation at the subtalar joint and ankle inversion compared to the intact state. Both operative procedures improved stability of the ankle complex, but tenodesis was unable to restore subtalar inversion and restricted ankle inversion in maximum plantarflexion. The Gould modification of Broström ligament repair may be a favorable operative procedure for the restoration of subtalar and ankle joint kinematics.

  8. Joint experiments using ETS-5

    NASA Astrophysics Data System (ADS)

    Nakata, Mutsumi

    1993-03-01

    An overview of the PARTNERS (Pan-Pacific Regional Telecommunications Network Research Satellite) project, which is the post-mission utilization of the ETS-5 (Engineering Test Satellite-5) is presented. The project was registered at SAFISY (Space Agency Forum for International Space Year) and includes the following experiments: (1) research on radio propagation characteristics in satellite links in Pan-Pacific region; (2) joint study on development of rural satellite network using simple mobile station; (3) experiments on telecommunication using personal computers for academic network; (4) experiments on remote education and training through satellite networks; (5) experiments on remote medicine; (6) experiments on the operation of medical information data base; (7) experiments on transmission of the earth observation data; and (8) demonstration of real time transmission of Asia-Pacific ISY (International Space Year) Conference. The experiment systems consisting of space segment (ETS-5) and simple and low cost ground system composed of 1.2 m aperture parabolic antenna, TV (Television) conference system, and terminal equipment are outlined.

  9. Three-dimensional reconstruction of rat knee joint using episcopic fluorescence image capture.

    PubMed

    Takaishi, R; Aoyama, T; Zhang, X; Higuchi, S; Yamada, S; Takakuwa, T

    2014-10-01

    Development of the knee joint was morphologically investigated, and the process of cavitation was analyzed by using episcopic fluorescence image capture (EFIC) to create spatial and temporal three-dimensional (3D) reconstructions. Knee joints of Wister rat embryos between embryonic day (E)14 and E20 were investigated. Samples were sectioned and visualized using an EFIC. Then, two-dimensional image stacks were reconstructed using OsiriX software, and 3D reconstructions were generated using Amira software. Cavitations of the knee joint were constructed from five divided portions. Cavity formation initiated at multiple sites at E17; among them, the femoropatellar cavity (FPC) was the first. Cavitations of the medial side preceded those of the lateral side. Each cavity connected at E20 when cavitations around the anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were completed. Cavity formation initiated from six portions. In each portion, development proceeded asymmetrically. These results concerning anatomical development of the knee joint using EFIC contribute to a better understanding of the structural feature of the knee joint. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric

    2005-11-01

    To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.

  11. International Space Station (ISS)

    NASA Image and Video Library

    2006-09-17

    This view of the International Space Station, back dropped against the blackness of space and Earth, was taken shortly after the Space Shuttle Atlantis undocked from the orbital outpost at 7:50 a.m. CDT during the STS-115 mission. The unlinking completed after six days, two hours and two minutes of joint operations of the installation of the P3/P4 truss. The new 17 ton truss included batteries, electronics, a giant rotating joint, and sported a second pair of 240-foot solar wings. The new solar arrays will eventually double the onboard power of the Station when their electrical systems are brought online during the next shuttle flight, STS-116.

  12. Joint sealant study

    DOT National Transportation Integrated Search

    1987-09-01

    ADOT has approximately 550 lane miles of jointed portland cement pavement under its jurisdiction. The current practice is to saw and seal the joints at the time of construction and reseal the joints under a rehabilitation project. ADOT does not speci...

  13. A reduced Iwan model that includes pinning for bolted joint mechanics

    DOE PAGES

    Brake, M. R. W.

    2016-10-28

    Bolted joints are prevalent in most assembled structures; however, predictive models for their behavior do not exist. Calibrated models, such as the Iwan model, are able to predict the response of a jointed structure over a range of excitations once calibrated at a nominal load. The Iwan model, though, is not widely adopted due to the high computational expense of implementation. To address this, an analytical solution of the Iwan model is derived under the hypothesis that for an arbitrary load reversal, there is a new distribution of dry friction elements, which are now stuck, that approximately resemble a scaledmore » version of the original distribution of dry friction elements. The dry friction elements internal to the Iwan model do not have a uniform set of parameters and are described by a distribution of parameters, i.e., which internal dry friction elements are stuck or slipping at a given load, that ultimately governs the behavior of the joint as it transitions from microslip to macroslip. This hypothesis allows the model to require no information from previous loading cycles. Additionally, the model is extended to include the pinning behavior inherent in a bolted joint. Modifications of the resulting framework are discussed to highlight how the constitutive model for friction can be changed (in the case of an Iwan–Stribeck formulation) or how the distribution of dry friction elements can be changed (as is the case for the Iwan plasticity model). Finally, the reduced Iwan plus pinning model is then applied to the Brake–Reuß beam in order to discuss methods to deduce model parameters from experimental data.« less

  14. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion.

    PubMed

    Langohr, G Daniel G; Giles, Joshua W; Athwal, George S; Johnson, James A

    2015-06-01

    Little is known about the effects of glenosphere diameter on shoulder joint loads. The purpose of this biomechanical study was to investigate the effects of glenosphere diameter on joint load, load angle, and total deltoid force required for active abduction and range of motion in internal/external rotation and abduction. A custom, instrumented reverse shoulder arthroplasty implant system capable of measuring joint load and varying glenosphere diameter (38 and 42 mm) and glenoid offset (neutral and lateral) was implanted in 6 cadaveric shoulders to provide at least 80% power for all variables. A shoulder motion simulator was used to produce active glenohumeral and scapulothoracic motion. All implant configurations were tested with active and passive motion with joint kinematics, loads, and moments recorded. At neutral and lateralized glenosphere positions, increasing diameter significantly increased joint load (+12 ± 21 N and +6 ± 9 N; P < .01) and deltoid load required for active abduction (+9 ± 22 N and +11 ± 15 N; P < .02), whereas joint load angle was unaffected (P > .8). Passive internal rotation was reduced with increased diameter at both neutral and lateralized glenosphere positions (-6° ± 6° and -12° ± 6°; P < .002); however, external rotation was not affected (P > .05). At neutral glenosphere position, increasing diameter increased the maximum angles of both adduction (+1° ± 1°; P = .03) and abduction (+8° ± 9°; P < .05). Lateralization also increased abduction range of motion compared with neutral (P < .01). Although increasing glenosphere diameter significantly increased joint load and deltoid force, the clinical impact of these changes is presently unclear. Internal rotation, however, was reduced, which contradicts previous bone modeling studies, which we postulate is due to increased posterior capsular tension as it is forced to wrap around a larger 42 mm implant assembly. Copyright © 2015 Journal of

  15. Internal rotor friction instability

    NASA Technical Reports Server (NTRS)

    Walton, J.; Artiles, A.; Lund, J.; Dill, J.; Zorzi, E.

    1990-01-01

    The analytical developments and experimental investigations performed in assessing the effect of internal friction on rotor systems dynamic performance are documented. Analytical component models for axial splines, Curvic splines, and interference fit joints commonly found in modern high speed turbomachinery were developed. Rotor systems operating above a bending critical speed were shown to exhibit unstable subsynchronous vibrations at the first natural frequency. The effect of speed, bearing stiffness, joint stiffness, external damping, torque, and coefficient of friction, was evaluated. Testing included material coefficient of friction evaluations, component joint quantity and form of damping determinations, and rotordynamic stability assessments. Under conditions similar to those in the SSME turbopumps, material interfaces experienced a coefficient of friction of approx. 0.2 for lubricated and 0.8 for unlubricated conditions. The damping observed in the component joints displayed nearly linear behavior with increasing amplitude. Thus, the measured damping, as a function of amplitude, is not represented by either linear or Coulomb friction damper models. Rotordynamic testing of an axial spline joint under 5000 in.-lb of static torque, demonstrated the presence of an extremely severe instability when the rotor was operated above its first flexible natural frequency. The presence of this instability was predicted by nonlinear rotordynamic time-transient analysis using the nonlinear component model developed under this program. Corresponding rotordynamic testing of a shaft with an interference fit joint demonstrated the presence of subsynchronous vibrations at the first natural frequency. While subsynchronous vibrations were observed, they were bounded and significantly lower in amplitude than the synchronous vibrations.

  16. Temporomandibular Joint Disorders: A Review of Etiology, Clinical Management, and Tissue Engineering Strategies

    PubMed Central

    Murphy, Meghan K.; MacBarb, Regina F.; Wong, Mark E.; Athanasiou, Kyriacos A.

    2015-01-01

    Epidemiology reports state temporomandibular joint disorders (TMD) affect up to 25% of the population, yet their etiology and progression are poorly understood. As a result, treatment options are limited and fail to meet the long-term demands of the relatively young patient population. TMD are a class of degenerative musculoskeletal conditions associated with morphological and functional deformities. In up to 70% of cases, TMD are accompanied by malpositioning of the TMJ disc, termed “internal derangement.” Though onset is not well characterized, correlations between internal derangement and osteoarthritic change have been identified. Due to the complex and unique nature of each TMD case, diagnosis requires patient-specific analysis accompanied by various diagnostic modalities. Likewise, treatment requires customized plans to address the specific characteristics of each patient’s disease. In the mechanically demanding and biochemically active environment of the TMJ, therapeutic approaches capable of restoring joint functionality while responding to changes in the joint have become a necessity. Capable of integration and adaptation in the TMJ, one such approach, tissue engineering, carries significant potential in the development of repair and replacement tissues. The following review presents a synopsis of etiology, current treatment methods, and the future of tissue engineering for repairing and/or replacing diseased joint components, specifically the mandibular condyle and TMJ disc. Preceding the current trends in tissue engineering is an analysis of native tissue characterization, toward identifying tissue engineering objectives and validation metrics for restoring healthy and functional structures of the TMJ. PMID:24278954

  17. 26 CFR 1.2-1 - Tax in case of joint return of husband and wife or the return of a surviving spouse.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Tax in case of joint return of husband and wife..., DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Normal Taxes and Surtaxes § 1.2-1 Tax in case of joint..., 1971. (1) For taxable years ending before January 1, 1971, in the case of a joint return of husband and...

  18. The Joint Airlock Module is moved to a payload canister in the O&C

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Joint Airlock Module is suspended by an overhead crane in the Operations and Checkout Building before being moved and placed into the payload canister for transfer to the Space Station Processing Facility. There the module will undergo more preflight processing for the STS-104 mission scheduled for launch aboard Space Shuttle Atlantis May 17, 2001. The Joint Airlock Module is the gateway from which crew members aboard the International Space Station will enter and exit the 470-ton orbiting research facility.

  19. Joint swelling

    MedlinePlus

    ... of arthritis caused by buildup of uric acid crystals in a joint ( gout ) Arthritis caused by wear ... osteoarthritis ) Arthritis caused by buildup of calcium-type crystals in joints ( pseudogout ) Disorder that involves arthritis and ...

  20. A Parallel and Distributed Processing Model of Joint Attention, Social-Cognition and Autism

    PubMed Central

    Mundy, Peter; Sullivan, Lisa; Mastergeorge, Ann M.

    2009-01-01

    Scientific Abstract The impaired development of joint attention is a cardinal feature of autism. Therefore, understanding the nature of joint attention is a central to research on this disorder. Joint attention may be best defined in terms of an information processing system that begins to develop by 4–6 months of age. This system integrates the parallel processing of internal information about one’s own visual attention with external information about the visual attention of other people. This type of joint encoding of information about self and other attention requires the activation of a distributed anterior and posterior cortical attention network. Genetic regulation, in conjunction with self-organizing behavioral activity guides the development of functional connectivity in this network. With practice in infancy the joint processing of self-other attention becomes automatically engaged as an executive function. It can be argued that this executive joint-attention is fundamental to human learning, as well as the development of symbolic thought, social-cognition and social-competence throughout the life span. One advantage of this parallel and distributed processing model of joint attention (PDPM) is that it directly connects theory on social pathology to a range of phenomenon in autism associated with neural connectivity, constructivist and connectionist models of cognitive development, early intervention, activity-dependent gene expression, and atypical ocular motor control. PMID:19358304

  1. The joint flanker effect and the joint Simon effect: On the comparability of processes underlying joint compatibility effects.

    PubMed

    Dittrich, Kerstin; Bossert, Marie-Luise; Rothe-Wulf, Annelie; Klauer, Karl Christoph

    2017-09-01

    Previous studies observed compatibility effects in different interference paradigms such as the Simon and flanker task even when the task was distributed across two co-actors. In both Simon and flanker tasks, performance is improved in compatible trials relative to incompatible trials if one actor works on the task alone as well as if two co-actors share the task. These findings have been taken to indicate that actors automatically co-represent their co-actor's task. However, recent research on the joint Simon and joint flanker effect suggests alternative non-social interpretations. To which degree both joint effects are driven by the same underlying processes is the question of the present study, and it was scrutinized by manipulating the visibility of the co-actor. While the joint Simon effect was not affected by the visibility of the co-actor, the joint flanker effect was reduced when participants did not see their co-actors but knew where the co-actors were seated. These findings provide further evidence for a spatial interpretation of the joint Simon effect. In contrast to recent claims, however, we propose a new explanation of the joint flanker effect that attributes the effect to an impairment in the focusing of spatial attention contingent on the visibility of the co-actor.

  2. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  3. Altered Tibiofemoral Joint Contact Mechanics and Kinematics in Patients with Knee Osteoarthritis and Episodic Complaints of Joint Instability

    PubMed Central

    Farrokhi, Shawn; Voycheck, Carrie A.; Klatt, Brian A.; Gustafson, Jonathan A.; Tashman, Scott; Fitzgerald, G. Kelley

    2014-01-01

    Background To evaluate knee joint contact mechanics and kinematics during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. Methods Forty-three subjects, 11 with medial compartment knee osteoarthritis and self-reported instability (unstable), 7 with medial compartment knee osteoarthritis but no reports of instability (stable), and 25 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a downhill gait task on a treadmill. Findings The medial compartment contact point excursions were longer in the unstable group compared to the stable (p=0.046) and the control groups (p=0.016). The peak medial compartment contact point velocity was also greater for the unstable group compared to the stable (p=0.047) and control groups (p=0.022). Additionally, the unstable group demonstrated a coupled movement pattern of knee extension and external rotation after heel contact which was different than the coupled motion of knee flexion and internal rotation demonstrated by stable and control groups. Interpretation Our findings suggest that knee joint contact mechanics and kinematics are altered during the loading response phase of downhill gait in knee osteoarthritis patients with self-reported instability. The observed longer medial compartment contact point excursions and higher velocities represent objective signs of mechanical instability that may place the arthritic knee joint at increased risk for disease progression. Further research is indicated to explore the clinical relevance of altered contact mechanics and kinematics during other common daily activities and to assess the efficacy of rehabilitation programs to improve altered joint biomechanics in knee osteoarthritis patients with self-reported instability. PMID:24856791

  4. The Waist Width of Skis Influences the Kinematics of the Knee Joint in Alpine Skiing

    PubMed Central

    Zorko, Martin; Nemec, Bojan; Babič, Jan; Lešnik, Blaz; Supej, Matej

    2015-01-01

    Recently alpine skis with a wider waist width, which medially shifts the contact between the ski edge and the snow while turning, have appeared on the market. The aim of this study was to determine the knee joint kinematics during turning while using skis of different waist widths (65mm, 88mm, 110mm). Six highly skilled skiers performed ten turns on a predefined course (similar to a giant slalom course). The relation of femur and tibia in the sagital, frontal and coronal planes was captured by using an inertial motion capture suit, and Global Navigation Satellite System was used to determine the skiers’ trajectories. With respect of the outer ski the knee joint flexion, internal rotation and abduction significantly decreased with the increase of the ski waist width for the greatest part of the ski turn. The greatest abduction with the narrow ski and the greatest external rotation (lowest internal rotation) with the wide ski are probably the reflection of two different strategies of coping the biomechanical requirements in the ski turn. These changes in knee kinematics were most probably due to an active adaptation of the skier to the changed biomechanical conditions using wider skis. The results indicated that using skis with large waist widths on hard, frozen surfaces could bring the knee joint unfavorably closer to the end of the range of motion in transversal and frontal planes as well as potentially increasing the risk of degenerative knee injuries. Key points The change in the skis’ waist width caused a change in the knee joint movement strategies, which had a tendency to adapt the skier to different biomechanical conditions. The use of wider skis or, in particular, skis with a large waist width, on a hard or frozen surface, could unfavourably bring the knee joint closer to the end of range of motion in transversal and frontal planes as well as may potentially increase the risk of degenerative knee injuries. The overall results of the abduction and

  5. Joint forces and torques when walking in shallow water.

    PubMed

    Orselli, Maria Isabel Veras; Duarte, Marcos

    2011-04-07

    This study reports for the first time an estimation of the internal net joint forces and torques on adults' lower limbs and pelvis when walking in shallow water, taking into account the drag forces generated by the movement of their bodies in the water and the equivalent data when they walk on land. A force plate and a video camera were used to perform a two-dimensional gait analysis at the sagittal plane of 10 healthy young adults walking at comfortable speeds on land and in water at a chest-high level. We estimated the drag force on each body segment and the joint forces and torques at the ankle, knee, and hip of the right side of their bodies using inverse dynamics. The observed subjects' apparent weight in water was about 35% of their weight on land and they were about 2.7 times slower when walking in water. When the subjects walked in water compared with walking on land, there were no differences in the angular displacements but there was a significant reduction in the joint torques which was related to the water's depth. The greatest reduction was observed for the ankle and then the knee and no reduction was observed for the hip. All joint powers were significantly reduced in water. The compressive and shear joint forces were on average about three times lower during walking in water than on land. These quantitative results substantiate the use of water as a safe environment for practicing low-impact exercises, particularly walking. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Joint-Attention and the Social Phenotype of School-Aged Children with ASD.

    PubMed

    Mundy, Peter; Novotny, Stephanie; Swain-Lerro, Lindsey; McIntyre, Nancy; Zajic, Matt; Oswald, Tasha

    2017-05-01

    The validity of joint attention assessment in school-aged children with ASD is unclear (Lord, Jones, Journal of Child Psychology and Psychiatry 53(5):490-509, 2012). This study examined the feasibility and validity of a parent-report measure of joint attention related behaviors in verbal children and adolescents with ASD. Fifty-two children with ASD and 34 controls were assessed with the Childhood Joint Attention Rating Scale (C-JARS). The C-JARS exhibited internally consistency, α = 0.88, and one factor explained 49% of the scale variance. Factor scores correctly identified between 88 and 94% of the children with ASD and 62-82% of controls. These scores were correlated with the ADOS-2, but not other parent-report symptom measures. The C-JARS appears to assess a unique dimension of the social-phenotype of children with ASD.

  7. Mutual coordination strengthens the sense of joint agency in cooperative joint action.

    PubMed

    Bolt, Nicole K; Poncelet, Evan M; Schultz, Benjamin G; Loehr, Janeen D

    2016-11-01

    Philosophers have proposed that when people coordinate their actions with others they may experience a sense of joint agency, or shared control over actions and their effects. However, little empirical work has investigated the sense of joint agency. In the current study, pairs coordinated their actions to produce tone sequences and then rated their sense of joint agency on a scale ranging from shared to independent control. People felt more shared than independent control overall, confirming that people experience joint agency during joint action. Furthermore, people felt stronger joint agency when they (a) produced sequences that required mutual coordination compared to sequences in which only one partner had to coordinate with the other, (b) held the role of follower compared to leader, and (c) were better coordinated with their partner. Thus, the strength of joint agency is influenced by the degree to which people mutually coordinate with each other's actions. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. International Space Station (ISS)

    NASA Image and Video Library

    2000-10-29

    The Soyuz TM-31 launch vehicle is shown in the vertical position for its launch from Baikonur, carrying the first resident crew to the International Space Station. The Russian Soyuz launch vehicle is an expendable spacecraft that evolved out of the original Class A (Sputnik). From the early 1960s until today, the Soyuz launch vehicle has been the backbone of Russia's marned and unmanned space launch fleet. Today, the Soyuz launch vehicle is marketed internationally by a joint Russian/French consortium called STARSEM. As of August 2001, there have been ten Soyuz missions under the STARSEM banner.

  9. International Space Station (ISS)

    NASA Image and Video Library

    2000-10-29

    The Soyuz TM-31 launch vehicle, which carried the first resident crew to the International Space Station, moves toward the launch pad at the Baikonur complex in Kazakhstan. The Russian Soyuz launch vehicle is an expendable spacecraft that evolved out of the original Class A (Sputnik). From the early 1960' until today, the Soyuz launch vehicle has been the backbone of Russia's marned and unmanned space launch fleet. Today, the Soyuz launch vehicle is marketed internationally by a joint Russian/French consortium called STARSEM. As of August 2001, there have been ten Soyuz missions under the STARSEM banner.

  10. Joint Chiefs of Staff > Leadership

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Joint Staff Organizational Chart Joint Chiefs of Staff Links Home Today in DOD About DOD Top Issues News Photos/Videos

  11. Chondromalacia as pathological finding in arthroscopy of the temporomandibular joint: A retrospective study.

    PubMed

    Martin-Granizo, Rafael; Correa-Muñoz, Diana Carolina

    2018-01-01

    The objective of this study was to describe the arthroscopic findings of chondromalacia and its relation with the internal derangement of the temporomandibular joint (TMJ). A total of 161 patients (299 TMJs) who underwent arthroscopy were included in the study. The TMJs were evaluated objectively under arthroscopic vision, and 4 groups of patients were established according to the degree of involvement, degree I, II, III and IV. Statistical analyses were conducted using logistic regression models (P < 0.05). It was observed that 95 patients (59%) had no sign of chondromalacia and 66 (41%) in 88 joints exhibited some degree of chondromalacia (44 patients unilaterally and 22 bilaterally). Of the 88 joints with chondromalacia, 14 (15.9%) had chondromalacia degree I, 12 (13.6%) chondromalacia degree II, 20 (22.7%) chondromalacia degree III and 42 (47.7%) chondromalacia degree IV. The chondromalacia was more significantly found in patients with ADDwR and discal perforation (P < 0.05), even as a common finding in patients without any internal deragement. Chondromalacia degree IV was a significant finding in cases of ADDwoR (P = 0.000619). Chondromalacia of the TMJ is a common finding in patients with internal derangement even at the early stages. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Maternal and paternal physical abuse: Unique and joint associations with child behavioral problems.

    PubMed

    Cui, Naixue; Deatrick, Janet A; Liu, Jianghong

    2018-02-01

    Although there is a substantial amount of literature documenting the relationship between child abuse and behavioral problems in China, there is, on the other hand, a limited number of studies on the joint and unique associations of maternal and paternal physical abuse with child behaviors within the Chinese context. The present study, using the family systems theory as the theoretical framework, aims to examine these joint and the unique associations of maternal and paternal physical abuse with externalizing and internalizing behaviors among a community sample of Chinese children. A total of 296 children (54.7% boys, mean age 12.31±0.56years) from two-parent families participated in the study, and they reported their physical abuse experience by their mother and father in the previous year using the Chinese version of the Parent-Child Conflict Tactics Scale. Participants, using the Youth Self Report, reported personal externalizing and internalizing behaviors, and, similarly, their mothers, using the Child Behavior Checklist, assessed children's externalizing and internalizing behaviors. Linear mixed effect models with random intercept and slope were used to examine the joint and unique associations of maternal and paternal physical abuse with child externalizing and internalizing behaviors. Results revealed that physically abused children were more likely to be simultaneously abused by both mothers and fathers. Furthermore, when compared with their non-abused counterparts, children with physical abuse that was carried out solely by mothers (externalizing behaviors: β=6.71, 95% CI=2.45-10.98, p<0.01; internalizing behaviors: β=4.52, 95% CI=0.37-8.66, p<0.05) or by both mothers and fathers (externalizing behaviors: β=4.52, 95% CI=1.80-7.24, p<0.001; internalizing behaviors: β=2.98, 95% CI=0.34-5.61, p<0.05) reported more externalizing and internalizing behaviors. Externalizing and internalizing behaviors of children who were physically abused solely by fathers

  13. Signaling networks in joint development

    PubMed Central

    Salva, Joanna E.; Merrill, Amy E.

    2016-01-01

    Here we review studies identifying regulatory networks responsible for synovial, cartilaginous, and fibrous joint development. Synovial joints, characterized by the fluid-filled synovial space between the bones, are found in high-mobility regions and are the most common type of joint. Cartilaginous joints unite adjacent bones through either a hyaline cartilage or fibrocartilage intermediate. Fibrous joints, which include the cranial sutures, form a direct union between bones through fibrous connective tissue. We describe how the distinct morphologic and histogenic characteristics of these joint classes are established during embryonic development. Collectively, these studies reveal that despite the heterogeneity of joint strength and mobility, joint development throughout the skeleton utilizes common signaling networks via long-range morphogen gradients and direct cell-cell contact. This suggests that different joint types represent specialized variants of homologous developmental modules. Identifying the unifying aspects of the signaling networks between joint classes allows a more complete understanding of the signaling code for joint formation, which is critical to improving strategies for joint regeneration and repair. PMID:27859991

  14. Expression of immune response genes in the stifle joint of dogs with oligoarthritis and degenerative cranial cruciate ligament rupture.

    PubMed

    Muir, P; Schaefer, S L; Manley, P A; Svaren, J P; Oldenhoff, W E; Hao, Z

    2007-10-15

    Dysregulation of immune responses within joints plays an important role in development of inflammatory arthritis. We determined expression of a panel of immune response and matrix turnover genes in synovial fluid collected from a group of dogs with stifle oligoarthritis and associated degenerative cranial cruciate ligament (CCL) rupture (n=27). We also studied synovial fluid gene expression in dogs affected with other forms of degenerative arthritis (n=9) and in the stifle joint of healthy dogs with intact CCL (n=14). After collection, synovial cells were pelleted and RNA was isolated. Relative expression of cathepsin K, cathepsin S, tartrate-resistant acid phosphatase (TRAP), matrix metalloproteinase-9 (MMP-9), invariant chain (li), toll-like receptor-2 (TLR-2), and TLR-9 was determined using real-time quantitative RT-PCR. Data were normalized to peripheral blood mononuclear cells (PBMC) as an internal control. Relative expression of cathepsin K, MMP-9, TRAP, and li was increased in the stifle synovial fluid of dogs with oligoarthritis, when compared with the stifles of healthy dogs (P<0.05). In contrast, relative expression of all of the genes-of-interest in synovial fluid from joints affected with other forms of arthritis was not significantly different from the stifles of healthy dogs. TRAP expression was also significantly increased in the stifle joints of dogs with oligoarthritis, when compared to joint expression of TRAP in dogs with other forms of degenerative arthritis (P<0.05). In the dogs with stifle oligoarthritis, expression of both matrix turnover and immune response genes was increased in stifle synovial fluid, when compared with the internal PBMC control, whereas in healthy dogs and dogs with other forms of arthritis, only expression of matrix turnover genes was increased in synovial fluid, when compared with the internal PBMC control (P<0.05). Taken together, these findings suggest that antigen-specific immune responses within the stifle joint may

  15. Effects of glucosamine-chondroitin combination on synovial fluid IL-1β, IL-6, TNF-α and PGE2 levels in internal derangements of temporomandibular joint

    PubMed Central

    Esen, Emin; Tatli, Ufuk

    2015-01-01

    Background The aim of the present study was to evaluate the effects of glucosamine-chondroitin sulphate combination on internal derangements of temporomandibular joint in clinical and biochemical manners. Material and Methods This randomized clinical study included 31 cases reporting joint tenderness, in which disc displacement was detected on MR imaging. In all patients, synovial fluid sampling was performed under local anesthesia. In the study group, the patients were prescribed a combination of 1500 mg glucosamine and 1200 mg chondroitin sulphate, while patients in the control group were only prescribed 50 mg tramadol HCl (twice daily) for pain control. After 8 weeks, synovial fluid sampling was repeated in the same manner. The levels of pain, maximum mouth opening (MMO), synovial fluid IL-1ß, IL-6, TNF-α and PGE2 measured before and after pharmacological intervention were compared. Results The reduction in pain levels was significant in both groups. There was no significant difference between two groups in terms of pain reduction. The improvement in MMO was significant in the study group but it was not in the control group. The MMO improvement was significantly higher in the study group compared to the control group. In the study group, significant decrease was observed in PGE2 level, while the decreases in IL-1β, IL-6 and TNF-α levels were not significant. In the control group, no significant decrease was observed in any of the inflammatory cytokines after 8 weeks, moreover IL-1ß and IL-6 levels were increased. Alterations of IL-1ß and IL-6 levels were significant in study group while TNF-α and PGE2 levels were not, compared to control group. Conclusions In conclusion, these results might suggest that glucosamine-chondroitin combination significantly increases the MMO and decreases the synovial fluid IL1β and IL6 levels in internal derangements of TMJ compared to tramadol. The modifications of synovial fluid TNF-α and PGE2 levels do not reach

  16. Knee joint position sense ability in elite athletes who have returned to international level play following ACL reconstruction: A cross-sectional study.

    PubMed

    Relph, Nicola; Herrington, Lee

    2016-12-01

    Following an ACL injury, reconstruction (ACL-R) and rehabilitation, athletes may return to play with a proprioceptive deficit. However, literature is lacking to support this hypothesis in elite athletic groups who have returned to international levels of performance. It is possible the potentially heightened proprioceptive ability evidenced in athletes may negate a deficit following injury. The purpose of this study was to consider the effects of ACL injury, reconstruction and rehabilitation on knee joint position sense (JPS) on a group of elite athletes who had returned to international performance. Using a cross-sectional design ten elite athletes with ACL-R and ten controls were evaluated. JPS was tested into knee extension and flexion using absolute error scores. Average data with 95% confidence intervals between the reconstructed, contralateral and uninjured control knees were analyzed using t-tests and effect sizes. The reconstructed knee of the injured group demonstrated significantly greater angle of error scores when compared to the contralateral and uninjured control into knee flexion (p=0.0001, r=0.98) and knee extension (p=0.0001, r=0.91). There were no significant differences between the contralateral uninjured knee of the injured group and the uninjured control group. Elite athletes who have had an ACL injury, reconstruction, rehabilitation and returned to international play demonstrate lower JPS ability compared to control groups. It is unclear if this deficiency affects long-term performance or secondary injury and re-injury problems. In the future physical therapists should monitor athletes longitudinally when they return to play. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Assessment of articular disc displacement of temporomandibular joint with ultrasound.

    PubMed

    Razek, Ahmed Abdel Khalek Abdel; Al Mahdy Al Belasy, Fouad; Ahmed, Wael Mohamed Said; Haggag, Mai Ahmed

    2015-06-01

    To assess pattern of articular disc displacement in patients with internal derangement (ID) of temporomandibular joint (TMJ) with ultrasound. Prospective study was conducted upon 40 TMJ of 20 patients (3 male, 17 female with mean age of 26.1 years) with ID of TMJ. They underwent high-resolution ultrasound and MR imaging of TMJ. The MR images were used as the gold standard for calculating sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) of ultrasound for diagnosis of anterior or sideway displacement of the disc. The anterior displaced disc was seen in 26 joints at MR and 22 joints at ultrasound. The diagnostic efficacy of ultrasound for anterior displacement has sensitivity of 79.3 %, specificity of 72.7 %, accuracy of 77.5 %, PPV of 88.5 %, NPV of 57.1 %, PLR of 2.9 and NLR of 0.34. The sideway displacement of disc was seen in four joints at MR and three joints at ultrasound. The diagnostic efficacy of ultrasound for sideway displacement has a sensitivity of 75 %, specificity of 63.6 %, accuracy of 66.7 %, PPV of 42.8, NPV of 87.5 %, PLR of 2.06, and NLR of 0.39. We concluded that ultrasound is a non-invasive imaging modality used for assessment of anterior and sideway displacement of the articular disc in patients with ID of TMJ.

  18. Biomechanical study of tarsometatarsal joint fusion using finite element analysis.

    PubMed

    Wang, Yan; Li, Zengyong; Zhang, Ming

    2014-11-01

    Complications of surgeries in foot and ankle bring patients with severe sufferings. Sufficient understanding of the internal biomechanical information such as stress distribution, contact pressure, and deformation is critical to estimate the effectiveness of surgical treatments and avoid complications. Foot and ankle is an intricate and synergetic system, and localized intervention may alter the functions to the adjacent components. The aim of this study was to estimate biomechanical effects of the TMT joint fusion using comprehensive finite element (FE) analysis. A foot and ankle model consists of 28 bones, 72 ligaments, and plantar fascia with soft tissues embracing all the segments. Kinematic information and ground reaction force during gait were obtained from motion analysis. Three gait instants namely the first peak, second peak and mid-stance were simulated in a normal foot and a foot with TMT joint fusion. It was found that contact pressure on plantar foot increased by 0.42%, 19% and 37%, respectively after TMT fusion compared with normal foot walking. Navico-cuneiform and fifth meta-cuboid joints sustained 27% and 40% increase in contact pressure at second peak, implying potential risk of joint problems such as arthritis. Von Mises stress in the second metatarsal bone increased by 22% at midstance, making it susceptible to stress fracture. This study provides biomechanical information for understanding the possible consequences of TMT joint fusion. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Scoping medical tourism and international hospital accreditation growth.

    PubMed

    Woodhead, Anthony

    2013-01-01

    Uwe Reinhardt stated that medical tourism can do to the US healthcare system what the Japanese automotive industry did to American carmakers after Japanese products developed a value for money and reliability reputation. Unlike cars, however, healthcare can seldom be test-driven. Quality is difficult to assess after an intervention (posteriori), therefore, it is frequently evaluated via accreditation before an intervention (a priori). This article aims to scope the growth in international accreditation and its relationship to medical tourism markets. Using self-reported data from Accreditation Canada, Joint Commission International (JCI) and Australian Council on Healthcare Standards (ACHS), this article examines how quickly international accreditation is increasing, where it is occurring and what providers have been accredited. Since January 2000, over 350 international hospitals have been accredited; the JCI's total nearly tripling between 2007-2011. Joint Commission International staff have conducted most international accreditation (over 90 per cent). Analysing which countries and regions where the most international accreditation has occurred indicates where the most active medical tourism markets are. However, providers will not solely be providing care for medical tourists. Accreditation will not mean that mistakes will never happen, but that accredited providers are more willing to learn from them, to varying degrees. If a provider has been accredited by a large international accreditor then patients should gain some reassurance that the care they receive is likely to be a good standard. The author questions whether commercializing international accreditation will improve quality, arguing that research is necessary to assess the accreditation of these growing markets.

  20. [Operative treatment and curative effects of the deltoid ligament injuries of the ankle joint].

    PubMed

    Cong, Pei-Jun; Liu, Bai-Hong; Wang, Ji-Ping; Qiao, Yong-Ping

    2009-12-01

    To explore the operative methods and curative effects of the deltoid ligament injuries. From 2002 to 2008, all 61 patients with ankle fractures complicated with deltoid ligament injuries were treated with open reduction and firm internal fixation. Among the patients, 39 patients were male and 22 patients were female, ranging in age from 14 to 71 years, with an average of 41 years. During the operation, the deltoid ligament was reconstructed to restore the medial and lateral stability of ankle joint. All the patients were followed up ranged from 5 to 30 months, with an average of 17 months. Fifty-nine patients had incision healed at the first stage; 2 patients had superficial infections at lateral malleolus, and healed at the 3rd week after changing dressings. The incisions at the internal medial malleolus were all healed at the first stage. According to Qi evaluation criteria, 35 patients got an excellent result, 13 good and 13 fair. The deltoid ligament should be treated properly in the treatment of ankle joint fractures when open reduction and firm internal fixation were emphasized.

  1. On Teaching International Courses on Health Information Systems

    PubMed Central

    Bauer, Axel W.; Bott, Oliver J.; Gietzelt, Matthias; Haarbrandt, Birger; Hackl, Werner O.; Hellrung, Nils; Hübner-Bloder, Gudrun; Jahn, Franziska; Jaspers, Monique W.; Kutscha, Ulrike; Machan, Christoph; Oppermann, Bianca; Pilz, Jochen; Schwartze, Jonas; Seidel, Christoph; Slot, Jan-Eric; Smers, Stefan; Spitalewsky, Katharina; Steckel, Nathalie; Strübing, Alexander; van der Haak, Minne

    2017-01-01

    Summary Background Health information systems (HIS) are one of the most important areas for biomedical and health informatics. In order to professionally deal with HIS well-educated informaticians are needed. Because of these reasons, in 2001 an international course has been established: The Frank – van Swieten Lectures on Strategic Information Management of Health Information Systems. Objectives Reporting about the Frank – van Swieten Lectures and about our students‘ feedback on this course during the last 16 years. Summarizing our lessons learned and making recommendations for such international courses on HIS. Methods The basic concept of the Frank – van Swieten lectures is to teach the theoretical background in local lectures, to organize practical exercises on modelling sub-information systems of the respective local HIS and finally to conduct Joint Three Days as an international meeting were the resulting models are introduced and compared. Results During the last 16 years, the Universities of Amsterdam, Braunschweig, Heidelberg/Heilbronn, Leipzig as well as UMIT were involved in running this course. Overall, 517 students from these universities participated. Our students‘ feedback was clearly positive. The Joint Three Days of the Frank – van Swieten Lectures, where at the end of the course all students can meet, turned out to be an important component of this course. Based on the last 16 years, we recommend common teaching materials, agreement on equivalent clinical areas for the exercises, support of group building of international student groups, motivation of using a collaboration platform, ensuring quality management of the course, addressing different levels of knowledge of the students, and ensuring sufficient funding for joint activities. Conclusions Although associated with considerable additional efforts, we can clearly recommend establishing such international courses on HIS, such as the Frank – van Swieten Lectures. PMID:28272648

  2. The Joint Airlock Module is moved to the payload canister

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- In the Space Station Processing Facility, the Joint Airlock Module is moved closer to the payload canister. The airlock will be installed in the payload bay of Atlantis for mission STS-104 to the International Space Station. The airlock is a pressurized flight element consisting of two cylindrical chambers attached end-to-end by a connecting bulkhead and hatch. Once installed and activated, the Airlock becomes the primary path for spacewalk entry to and departure from the Space Station for U.S. spacesuits, which are known as Extravehicular Mobility Units, or EMUs. In addition, the Joint Airlock is designed to support the Russian Orlan spacesuit for EVA activity. STS-104 is scheduled for launch June 14 from Launch Pad 39B.

  3. Combined acromioclavicular joint dislocation and coracoid avulsion in an adult.

    PubMed

    Naik, Monappa; Tripathy, Sujit Kumar; Goyal, Saumitra; Rao, Sarath K

    2015-05-20

    Avulsion fracture of coracoid process with acromioclavicular joint dislocation is extremely rare. We report a case of coracoid avulsion with acromioclavicular disruption in a 24-year-old man who sustained injuries in a road traffic accident. Although acromioclavicular (AC) dislocation was obvious from an initial radiograph, coracoid avulsion was picked up in a CT scan. Open reduction and internal fixations of the coracoid with a 4 mm cannulated screw, an AC joint with two K-wires and an anchor suture, resulted in rapid recovery. The patient had complete range of shoulder movements at the end of 3 months and he resumed his professional activities. After 1 year, he had normal shoulder movement without any functional limitations. 2015 BMJ Publishing Group Ltd.

  4. Combined acromioclavicular joint dislocation and coracoid avulsion in an adult

    PubMed Central

    Naik, Monappa; Tripathy, Sujit Kumar; Goyal, Saumitra; Rao, Sarath K

    2015-01-01

    Avulsion fracture of coracoid process with acromioclavicular joint dislocation is extremely rare. We report a case of coracoid avulsion with acromioclavicular disruption in a 24-year-old man who sustained injuries in a road traffic accident. Although acromioclavicular (AC) dislocation was obvious from an initial radiograph, coracoid avulsion was picked up in a CT scan. Open reduction and internal fixations of the coracoid with a 4 mm cannulated screw, an AC joint with two K-wires and an anchor suture, resulted in rapid recovery. The patient had complete range of shoulder movements at the end of 3 months and he resumed his professional activities. After 1 year, he had normal shoulder movement without any functional limitations. PMID:25994429

  5. Functional aspects of cross-legged sitting with special attention to piriformis muscles and sacroiliac joints.

    PubMed

    Snijders, Chris J; Hermans, Paul F G; Kleinrensink, Gerrit Jan

    2006-02-01

    Transversely oriented pelvic muscles such as the internal abdominal oblique, transversus abdominis, piriformis and pelvic floor muscles may contribute to sacroiliac joint stability by pressing the sacrum between the hipbones. Surface electromyographic measurements showed that leg crossing lowers the activity of the internal oblique abdominal muscle significantly. This suggests that leg crossing is a substitute for abdominal muscle activity. No previous studies addressed piriformis muscle and related pelvic structures in cross-legged sitting. Angles of pelvis and femur were measured in healthy subjects in standing, normal sitting and cross-legged sitting, and were used to simulate these postures on embalmed pelvises and measure piriformis muscle elongation. Deformations of pelvic ring and iliolumbar ligament caused by piriformis muscle force were measured on embalmed pelvises. Cross-legged sitting resulted in a relative elongation of the piriformis muscle of 11.7% compared to normal sitting and even 21.4% compared to standing. Application of piriformis muscle force resulted in inward deformation of the pelvic ring and compression of the sacroiliac joints and the dorsal side of the pubic symphysis. Cross-legged sitting is common. We believe that it contributes to sacroiliac joint stability. This study demonstrates the influence of the piriformis muscle on sacroiliac joint compression. The elongation of the piriformis muscle bilaterally by crossing the legs may be functional in the build-up of active or passive tension between sacrum and femur.

  6. Joint implementation: Biodiversity and greenhouse gas offsets

    NASA Astrophysics Data System (ADS)

    Cutright, Noel J.

    1996-11-01

    One of the most pressing environmental issues today is the possibility that projected increases in global emissions of greenhouse gases from increased deforestation, development, and fossil-fuel combustion could significantly alter global climate patterns. Under the terms of the United Nations Framework Convention on Climate Change, signed in Rio de Janeiro during the June 1992 Earth Summit, the United States and other industrialized countries committed to balancing greenhouse gas emissions at 1990 levels in the year 2000. Included in the treaty is a provision titled “Joint Implementation,” whereby industrialized countries assist developing countries in jointly modifying long-term emission trends, either through emission reductions or by protecting and enhancing greenhouse gas sinks (carbon sequestration). The US Climate Action Plan, signed by President Clinton in 1993, calls for voluntary climate change mitigation measures by various sectors, and the action plan included a new program, the US Initiative on Joint Implementation. Wisconsin Electric decided to invest in a Jl project because its concept encourages creative, cost-effective solutions to environmental problems through partnering, international cooperation, and innovation. The project chosen, a forest preservation and management effort in Belize, will sequester more than five million tons of carbon dioxide over a 40-year period, will become economically selfsustaining after ten years, and will have substantial biodiversity benefits.

  7. Rubber Hand Illusion Affects Joint Angle Perception

    PubMed Central

    Butz, Martin V.; Kutter, Esther F.; Lorenz, Corinna

    2014-01-01

    The Rubber Hand Illusion (RHI) is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model. PMID:24671172

  8. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  9. Shear fracture of jointed steel plates of bolted joints under impact load

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.; Kobayashi, H.; Shin, H.-S.

    2013-07-01

    The present study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of bolted joints used in a car body, which contributes to crash simulations by CAE. We focus our attention on the shear fracture of the jointed steel plates of lap-bolted joints in the suspension of a car under impact load. Members of lap-bolted joints are modelled as a pair of steel plates connected by a bolt. One of the plates is a specimen subjected to plastic deformation and fracture and the other is a jig subjected to elastic deformation only. Three kinds of steel plate specimens are examined, i.e., a common steel plate with a tensile strength of 270 MPa and high tensile strength steel plates of 440 and 590 MPa used for cars. The impact shear test was performed using the split Hopkinson bar technique for tension impact, together with the static test using a universal testing machine INSTRON 5586. The behaviour of the shear stress and deformation up to rupture taking place in the joint was discussed. The obtained results suggest that a stress-based fracture criterion may be developed for the impact fracture of jointed steel plates of a lap-bolted joint.

  10. Lower-Limb Joint Coordination Pattern in Obese Subjects

    PubMed Central

    Ranavolo, Alberto; Donini, Lorenzo M.; Mari, Silvia; Serrao, Mariano; Silvetti, Alessio; Iavicoli, Sergio; Cava, Edda; Asprino, Rosa; Pinto, Alessandro; Draicchio, Francesco

    2013-01-01

    The coordinative pattern is an important feature of locomotion that has been studied in a number of pathologies. It has been observed that adaptive changes in coordination patterns are due to both external and internal constraints. Obesity is characterized by the presence of excess mass at pelvis and lower-limb areas, causing mechanical constraints that central nervous system could manage modifying the physiological interjoint coupling relationships. Since an altered coordination pattern may induce joint diseases and falls risk, the aim of this study was to analyze whether and how coordination during walking is affected by obesity. We evaluated interjoint coordination during walking in 25 obese subjects as well as in a control group. The time-distance parameters and joint kinematics were also measured. When compared with the control group, obese people displayed a substantial similarity in joint kinematic parameters and some differences in the time-distance and in the coupling parameters. Obese subjects revealed higher values in stride-to-stride intrasubjects variability in interjoint coupling parameters, whereas the coordinative mean pattern was unaltered. The increased variability in the coupling parameters is associated with an increased risk of falls and thus should be taken into account when designing treatments aimed at restoring a normal locomotion pattern. PMID:23484078

  11. Early, asymptomatic stage of degenerative joint disease in canine hip joints.

    PubMed

    Lust, G; Summers, B A

    1981-11-01

    The early stages of degenerative joint disease were investigated in coxofemoral joints from dogs with a hereditary predisposition to hip dysplasia. Alterations observed included mild nonsuppurative synovitis, increased volume of both synovial fluid and the ligamentum teres, and focal degenerative articular cartilage lesions. On radiologic examination, subluxation of the femoral head was seen, but only in the most severely affected joints. Synovial inflammation with increased synovial fluid and ligament volumes were indicators of early degenerative joint disease in dogs. These changes seemed to coincide with, or perhaps to precede, microscopic evidence for articular cartilage degeneration and occurred before radiologic abnormalities were detected.

  12. Joint Contact Stress

    PubMed Central

    Brand, Richard A

    2005-01-01

    A joint's normal mechanical history contributes to the maintenance of articular cartilage and underlying bone. Loading facilitates the flow of nutrients into cartilage and waste products away, and additionally provides the mechanical signals essential for normal cell and tissue maintenance. Deleteriously low or high contact stresses have been presumed to result in joint deterioration, and particular aspects of the mechanical environment may facilitate repair of damaged cartilage. For decades, investigators have explored static joint contact stresses (under some more or less arbitrary condition) as a surrogate of the relevant mechanical history. Contact stresses have been estimated in vitro in many joints and in a number of species, although only rarely in vivo. Despite a number of widely varying techniques (and spatial resolutions) to measure these contact stresses, reported ranges of static peak normal stresses are relatively similar from joint to joint across species, and in the range of 0.5 to 5.0 MPa. This suggests vertebrate diarthrodial joints have evolved to achieve similar mechanical design criteria. Available evidence also suggests some disorders of cartilage deterioration are associated with somewhat higher peak pressures ranging from 1-20 MPa, but overlapping the range of normal pressures. Some evidence and considerable logic suggests static contact stresses per se do not predict cartilage responses, but rather temporal aspects of the contact stress history. Static contact stresses may therefore not be a reasonable surrogate for biomechanical studies. Rather, temporal and spatial aspects of the loading history undoubtedly induce beneficial and deleterious biological responses. Finally, since all articular cartilage experiences similar stresses, the concept of a "weight-bearing" versus a "non-weight-bearing" joint seems flawed, and should be abandoned. PMID:16089079

  13. Introduction to the IEEE International Symposium on Applications of Ferroelectrics and International Symposium on Piezoresponse Force Microscopy and Nanoscale Phenomena in Polar Materials.

    PubMed

    Ye, Zuo-Guang; Tan, Xiaoli; Bokov, Alexei A

    2012-09-01

    The 20th IEEE International Symposium on Applications of Ferroelectrics (ISAF) was held on July 24-27, 2011, in Vancouver, British Columbia, Canada, jointly with the International Symposium on Piezoresponse Force Microscopy and Nanoscale Phenomena in Polar Materials (PFM). Over a period of four days, approximately 400 scientists, engineers, and students from around the world presented their work and discussed the latest developments in the field of ferroelectrics, related materials, and their applications. It is particularly encouraging to see that a large number of students (115) were attracted to the joint conference and presented high-quality research works. This trend is not only important to this conference series, but more importantly, it is vital to the future of the ferroelectrics field.

  14. Personal and Contextual Factors Related to Internalizing Problems during Adolescence

    ERIC Educational Resources Information Center

    Oliva, Alfredo; Parra, Águeda; Reina, M. Carmen

    2014-01-01

    Background: Over the past decades, ample empirical evidence has been collected about the factors linked to internalizing problems during adolescence. However, there is a lack of research that use holistic approaches to study the joint analysis of a series of contextual and personal variables considered to be related to internalizing problems.…

  15. Haemophilia Joint Health Score in healthy adults playing sports.

    PubMed

    Sluiter, D; Foppen, W; de Kleijn, P; Fischer, K

    2014-03-01

    To evaluate outcome of prophylactic clotting factor replacement in children with haemophilia, the Haemophilia Joint Health Score (HJHS) was developed aiming at scoring early joint changes in children aged 4-18. The HJHS has been used for adults on long-term prophylaxis but interpretation of small changes remains difficult. Some changes in these patients may be due to sports-related injuries. Evaluation of HJHS score in healthy adults playing sports could improve the interpretation of this score in haemophilic patients. The aim of this study was to evaluate the HJHS scores in a cohort of young, healthy men participating in sports. Concomitant with a project collecting MRI images of ankles and knees in normal young adults, HJHS scores were assessed in 30 healthy men aged 18-26, participating in sports one to three times per week. One physiotherapist assessed their clinical function using the HJHS 2.1. History of joint injuries was documented. MRI images were scored by a single radiologist, using the International Prophylaxis Study Group additive MRI score. Median age of the study group was 24.3 years (range 19.0-26.4) and median frequency of sports activities was three times per week (range 1-4). Six joints (five knees, one ankle) had a history of sports-related injury. The median overall HJHS score was 0 out of 124 (range 0-3), with 60% of subjects showing no abnormalities on HJHS. All joints were normal on MRI. These results suggest that frequent sports participation and related injuries are not related with abnormalities in HJHS scores. © 2013 John Wiley & Sons Ltd.

  16. An Audit of Emergency Department Accreditation Based on Joint Commission International Standards (JCI).

    PubMed

    Hashemi, Behrooz; Motamedi, Maryam; Etemad, Mania; Rahmati, Farhad; Forouzanfar, Mohammad Mehdi; Kaghazchi, Fatemeh

    2014-01-01

    Despite thousands of years from creation of medical knowledge, it not much passes from founding the health care systems. Accreditation is an effective mechanism for performance evaluation, quality enhancement, and the safety of health care systems. This study was conducted to assess the results of emergency department (ED) accreditation in Shohadaye Tajrish Hospital, Tehran, Iran, 2013 in terms of domesticated standards of joint commission international (JCI) standards. This cohort study with a four-month follow up was conducted in the ED of Shohadaye Tajrish Hospital in 2013. The standard evaluation checklist of Iran hospitals (based on JCI standards) included 24 heading and 337 subheading was used for this purpose. The effective possible causes of weak spots were found and their solutions considered. After correction, assessment of accreditation were repeated again. Finally, the achieved results of two periods were analyzed using SPSS version 20. Quality improvement, admission in department and patient assessment, competency and capability test for staffs, collection and analysis of data, training of patients, and facilities had the score of below 50%. The mean of total score for accreditation in ED in the first period was 60.4±30.15 percent and in the second period 68.9±22.9 (p=0.005). Strategic plans, head of department, head nurse, resident physician, responsible nurse for the shift, and personnel file achieved the score of 100%. Of total headings below 50% in the first period just in two cases, collection and analysis of data with growth of 40% as well as competency and capability test for staffs with growth of 17%, were reached to more than 50%. Based on findings of the present study, the ED of Shohadaye Tajrish hospital reached the score of below 50% in six heading of quality improvement, admission in department and patient assessment, competency and capability test for staffs, collection and analysis of data, training of patients, and facilities. While

  17. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  18. Modeling of Human Joint Structures.

    DTIC Science & Technology

    1982-09-01

    Acromioclavicular Joint .... ............. ... 20 Glenohumeral Joint .... ................ . 20 HIP JOINT .................. ...... 21 Iliofemoral Ligament...clavicle articulates with the manubrium of the sternum, and the acromioclavicular joint, where the clavicle articulates with the acromion process of the...the interclavicular ligament. Acromioclavicular Joint This articulation between the distal end of the clavicle and the acromion of the scapula is

  19. Joint Chiefs of Staff > Media

    Science.gov Websites

    Senior Enlisted Advisor Joint Staff History Joint Staff Inspector General Joint Staff Structure Origin of J8 | Force Structure, Resources & Assessment Contact Joint Staff Media News Videos Chairman's

  20. Kinetics of throwing arm joints and the trunk motion during an overarm distance throw by skilled Japanese elementary school boys.

    PubMed

    Kobayashi, Yasuto; Ae, Michiyoshi; Miyazaki, Akiyo; Fujii, Norihisa; Iiboshi, Akira; Nakatani, Hideki

    2016-09-01

    The purpose of this study was to investigate joint kinetics of the throwing arms and role of trunk motion in skilled elementary school boys during an overarm distance throw. Throwing motions of 42 boys from second, fourth, and sixth grade were videotaped with three high-speed cameras operating at 300 fps. Seven skilled boys from each grade were selected on the basis of throwing distance for three-dimensional kinetic analysis. Joint forces, torques, and torque powers of the throwing arm joints were calculated from reconstructed three-dimensional coordinate data smoothed at cut-off frequencies of 10.5-15 Hz and by the inverse dynamics method. Throwing distance and ball velocity significantly increased with school grade. The angular velocity of elbow extension before ball release increased with school grade, although no significant increase between the grades was observed in peak extension torque of elbow joint. The joint torque power of shoulder internal/external rotation tended to increase with school grade. When teaching the overarm throw, elementary school teachers should observe large backward twisting of trunk during the striding phase and should keep in mind that young children, such as second graders (age 8 years), will be unable to effectively utilise shoulder external/internal rotation during the throwing phase.

  1. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    NASA Technical Reports Server (NTRS)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  2. Butt Welding Joint of Aluminum Alloy by Space GHTA Welding Process in Vacuum

    NASA Astrophysics Data System (ADS)

    Suita, Yoshikazu; Shinike, Shuhei; Ekuni, Tomohide; Terajima, Noboru; Tsukuda, Yoshiyuki; Imagawa, Kichiro

    Aluminum alloys have been used widely in constructing various space structures including the International Space Station (ISS) and launch vehicles. For space applications, welding experiments on aluminum alloy were performed using the GHTA (Gas Hollow Tungsten Arc) welding process using a filler wire feeder in a vacuum. We investigated the melting phenomenon of the base metal and filler wire, bead formation, and the effects of wire feed speed on melting characteristics. The melting mechanism in the base metal during the bead on a plate with wire feed was similar to that for the melt run without wire feed. We clarified the effects of wire feed speed on bead sizes and configurations. Furthermore, the butt welded joint welded using the optimum wire feed speed, and the joint tensile strengths were evaluated. The tensile strength of the square butt joint welded by the pulsed DC GHTA welding with wire feed in a vacuum is nearly equal to that of the same joint welded by conventional GTA (Gas Tungsten Arc) welding in air.

  3. Water and fat separation in real-time MRI of joint movement with phase-sensitive bSSFP.

    PubMed

    Mazzoli, Valentina; Nederveen, Aart J; Oudeman, Jos; Sprengers, Andre; Nicolay, Klaas; Strijkers, Gustav J; Verdonschot, Nico

    2017-07-01

    To introduce a method for obtaining fat-suppressed images in real-time MRI of moving joints at 3 Tesla (T) using a bSSFP sequence with phase detection to enhance visualization of soft tissue structures during motion. The wrist and knee of nine volunteers were imaged with a real-time bSSFP sequence while performing dynamic tasks. For appropriate choice of sequence timing parameters, water and fat pixels showed an out-of-phase behavior, which was exploited to reconstruct water and fat images. Additionally, a 2-point Dixon sequence was used for dynamic imaging of the joints, and resulting water and fat images were compared with our proposed method. The joints could be visualized with good water-fat separation and signal-to-noise ratio (SNR), while maintaining a relatively high temporal resolution (5 fps in knee imaging and 10 fps in wrist imaging). The proposed method produced images of moving joints with higher SNR and higher image quality when compared with the Dixon method. Water-fat separation is feasible in real-time MRI of moving knee and wrist at 3 T. PS-bSSFP offers movies with higher SNR and higher diagnostic quality when compared with Dixon scans. Magn Reson Med 78:58-68, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  4. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints

    PubMed Central

    Avgoulas, Evangelos I.; Sutcliffe, Michael P. F.

    2016-01-01

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints. PMID:28773688

  5. A Review of Natural Joint Systems and Numerical Investigation of Bio-Inspired GFRP-to-Steel Joints.

    PubMed

    Avgoulas, Evangelos I; Sutcliffe, Michael P F

    2016-07-12

    There are a great variety of joint types used in nature which can inspire engineering joints. In order to design such biomimetic joints, it is at first important to understand how biological joints work. A comprehensive literature review, considering natural joints from a mechanical point of view, was undertaken. This was used to develop a taxonomy based on the different methods/functions that nature successfully uses to attach dissimilar tissues. One of the key methods that nature uses to join dissimilar materials is a transitional zone of stiffness at the insertion site. This method was used to propose bio-inspired solutions with a transitional zone of stiffness at the joint site for several glass fibre reinforced plastic (GFRP) to steel adhesively bonded joint configurations. The transition zone was used to reduce the material stiffness mismatch of the joint parts. A numerical finite element model was used to identify the optimum variation in material stiffness that minimises potential failure of the joint. The best bio-inspired joints showed a 118% increase of joint strength compared to the standard joints.

  6. A cross-sectional study of the relationship between serum sexual hormone levels and internal derangement of temporomandibular joint.

    PubMed

    Madani, A S; Shamsian, A A; Hedayati-Moghaddam, M R; Fathi-Moghadam, F; Sabooni, M R; Mirmortazavi, A; Golmohamadi, M

    2013-08-01

    Temporomandibular disorders (TMD) are defined as clinical conditions that involve the masticatory muscles, temporomandibular joint (TMJ) or both. The aim of this study was to evaluate serum 17β-oestradiol and progesterone levels in menstruating women affected by internal derangement of the TMJ. A total of 142 women (mean age 30·2 ± 6·7) who referred to medical diagnostic laboratory of Iranian Academic Centre for Education, Culture and Research (ACECR), Mashhad Branch, were enrolled during 2007 and 2008. Forty-seven individuals had disc displacement with reduction (Group IIa) according to Research Diagnostic Criteria (RDC)/TMD Axis I diagnosis. Radioimmunoassay was used for the detection of serum 17β-oestradiol and progesterone levels in all 142 subjects. The mean progesterone level was significantly higher in control group (11·6 ± 10·4 ng mL(-1) ) compared to women with TMD (8·4 ± 6·8 ng mL(-1) , P = 0·03). No significant difference was found in two groups regarding 17β-oestradiol level. Lower progesterone level in women with TMD can suggest the more important role of this hormone in the development of the disorder. © 2013 John Wiley & Sons Ltd.

  7. The Joint Airlock Module is moved to the payload canister

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- In the Space Station Processing Facility, workers standing inside the payload canister help guide the Joint Airlock Module into place. The airlock will be installed in the payload bay of Atlantis for mission STS-104 to the International Space Station. The airlock is a pressurized flight element consisting of two cylindrical chambers attached end-to-end by a connecting bulkhead and hatch. Once installed and activated, the Airlock becomes the primary path for spacewalk entry to and departure from the Space Station for U.S. spacesuits, which are known as Extravehicular Mobility Units, or EMUs. In addition, the Joint Airlock is designed to support the Russian Orlan spacesuit for EVA activity. STS-104 is scheduled for launch June 14 from Launch Pad 39B.

  8. The Joint Airlock Module is moved to the payload canister

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- In the Space Station Processing Facility, the Joint Airlock Module is lifted from its workstand for a transfer to the payload canister. The airlock will be installed in the payload bay of Atlantis for mission STS-104 to the International Space Station. The airlock is a pressurized flight element consisting of two cylindrical chambers attached end-to-end by a connecting bulkhead and hatch. Once installed and activated, the airlock becomes the primary path for spacewalk entry to and departure from the Space Station for U.S. spacesuits, which are known as Extravehicular Mobility Units, or EMUs. In addition, the Joint Airlock is designed to support the Russian Orlan spacesuit for EVA activity. STS-104 is scheduled for launch June 14 from Launch Pad 39B.

  9. Development of Joint Climate and Discharge Projections for the International Rhine River Basin - the CHR RheinBlick2050 Project

    NASA Astrophysics Data System (ADS)

    Görgen, K.; Pfister, L.

    2008-12-01

    The anticipated climate change will lead to modified hydro-meteorological regimes that influence discharge behaviour and hydraulics of rivers. This has variable impacts on managed (anthropogenic) and unmanaged (natural) systems, depending on their sensitivity and vulnerability (ecology, economy, infrastructure, transport, energy production, water management, etc.). Decision makers in these contexts need adequate adaptation strategies to minimize adverse effects of climate change, i.e. an improved knowledge on the potential impacts including uncertainties means an extension of the informed options open to users. The goal of the highly applied study presented here is the development of joint, consistent climate and discharge projections for the international Rhine River catchments (Switzerland, France, Germany, Netherlands) in order to assess future changes of hydro-meteorological regimes in the meso- and macroscale Rhine River catchments and to derive and improve the understanding of such impacts on hydrologic and hydraulic processes. The RheinBlick2050 project is an international effort initiated by the International Commission for the Hydrology of the Rhine Basin (CHR) in close cooperation with the International Commission for the Protection of the Rhine. The core experiment design foresees a data-synthesis, multi-model approach where (transient) (bias- corrected) regional climate change projections are used as forcing data for existing calibrated hydrological (and hydraulic) models at a daily temporal resolution over mesoscale catchments of the Rhine River. Mainly for validation purposes, hydro-meteorological observations from national weather services are compiled into a new consistent 5 km x 5 km reference dataset from 1961 to 2005. RCM data are mainly used from the ENSEMBLES project and other existing dynamical downscaling model runs to derive probabilistic ensembles and thereby also access uncertainties on a regional scale. A benchmarking is helping to

  10. The Envelope of Physiological Motion of the First Carpometacarpal Joint

    PubMed Central

    Crisco, Joseph J.; Patel, Tarpit; Halilaj, Eni; Moore, Douglas C.

    2015-01-01

    Much of the hand's functional capacity is due to the versatility of the motions at the thumb carpometacarpal (CMC) joint, which are presently incompletely defined. The aim of this study was to develop a mathematical model to completely describe the envelope of physiological motion of the thumb CMC joint and then to examine if there were differences in the kinematic envelope between women and men. In vivo kinematics of the first metacarpal with respect to the trapezium were computed from computed tomography (CT) volume images of 44 subjects (20M, 24F, 40.3 ± 17.7 yr) with no signs of CMC joint pathology. Kinematics of the first metacarpal were described with respect to the trapezium using helical axis of motion (HAM) variables and then modeled with discrete Fourier analysis. Each HAM variable was fit in a cyclic domain as a function of screw axis orientation in the trapezial articular plane; the RMSE of the fits was 14.5 deg, 1.4 mm, and 0.8 mm for the elevation, location, and translation, respectively. After normalizing for the larger bone size in men, no differences in the kinematic variables between sexes could be identified. Analysis of the kinematic data also revealed notable coupling of the primary rotations of the thumb with translation and internal and external rotations. This study advances our basic understanding of thumb CMC joint function and provides a complete description of the CMC joint for incorporation into future models of hand function. From a clinical perspective, our findings provide a basis for evaluating CMC pathology, especially the mechanically mediated aspects of osteoarthritis (OA), and should be used to inform artificial joint design, where accurate replication of kinematics is essential for long-term success. PMID:26201612

  11. In Vivo Kinematics of the Tibiotalar and Subtalar Joints in Asymptomatic Subjects: A High-Speed Dual Fluoroscopy Study.

    PubMed

    Roach, Koren E; Wang, Bibo; Kapron, Ashley L; Fiorentino, Niccolo M; Saltzman, Charles L; Bo Foreman, K; Anderson, Andrew E

    2016-09-01

    Measurements of joint kinematics are essential to understand the pathomechanics of ankle disease and the effects of treatment. Traditional motion capture techniques do not provide measurements of independent tibiotalar and subtalar joint motion. In this study, high-speed dual fluoroscopy images of ten asymptomatic adults were acquired during treadmill walking at 0.5 m/s and 1.0 m/s and a single-leg, balanced heel-rise. Three-dimensional (3D) CT models of each bone and dual fluoroscopy images were used to quantify in vivo kinematics for the tibiotalar and subtalar joints. Dynamic tibiotalar and subtalar mean joint angles often exhibited opposing trends during captured stance. During both speeds of walking, the tibiotalar joint had significantly greater dorsi/plantarflexion (D/P) angular ROM than the subtalar joint while the subtalar joint demonstrated greater inversion/eversion (In/Ev) and internal/external rotation (IR/ER) than the tibiotalar joint. During balanced heel-rise, only D/P and In/Ev were significantly different between the tibiotalar and subtalar joints. Translational ROM in the anterior/posterior (AP) direction was significantly greater in the subtalar than the tibiotalar joint during walking at 0.5 m/s. Overall, our results support the long-held belief that the tibiotalar joint is primarily responsible for D/P, while the subtalar joint facilitates In/Ev and IR/ER. However, the subtalar joint provided considerable D/P rotation, and the tibiotalar joint rotated about all three axes, which, along with translational motion, suggests that each joint undergoes complex, 3D motion.

  12. Cooperative Adaptive Output Regulation for Second-Order Nonlinear Multiagent Systems With Jointly Connected Switching Networks.

    PubMed

    Liu, Wei; Huang, Jie

    2018-03-01

    This paper studies the cooperative global robust output regulation problem for a class of heterogeneous second-order nonlinear uncertain multiagent systems with jointly connected switching networks. The main contributions consist of the following three aspects. First, we generalize the result of the adaptive distributed observer from undirected jointly connected switching networks to directed jointly connected switching networks. Second, by performing a new coordinate and input transformation, we convert our problem into the cooperative global robust stabilization problem of a more complex augmented system via the distributed internal model principle. Third, we solve the stabilization problem by a distributed state feedback control law. Our result is illustrated by the leader-following consensus problem for a group of Van der Pol oscillators.

  13. Non-terminal animal model of post-traumatic osteoarthritis induced by acute joint injury.

    PubMed

    Boyce, M K; Trumble, T N; Carlson, C S; Groschen, D M; Merritt, K A; Brown, M P

    2013-05-01

    Develop a non-terminal animal model of acute joint injury that demonstrates clinical and morphological evidence of early post-traumatic osteoarthritis (PTOA). An osteochondral (OC) fragment was created arthroscopically in one metacarpophalangeal (MCP) joint of 11 horses and the contralateral joint was sham operated. Eleven additional horses served as unoperated controls. Every 2 weeks, force plate analysis, flexion response, joint circumference, and synovial effusion scores were recorded. At weeks 0 and 16, radiographs (all horses) and arthroscopic videos (OC injured and sham joints) were graded. At week 16, synovium and cartilage biopsies were taken arthroscopically from OC injured and sham joints for histologic evaluation and the OC fragment was removed. OC fragments were successfully created and horses were free of clinical lameness after fragment removal. Forelimb gait asymmetry was observed at week 2 (P = 0.0012), while joint circumference (P < 0.0001) and effusion scores (P < 0.0001) were increased in injured limbs compared to baseline from weeks 2 to 16. Positive flexion response of injured limbs was noted at multiple time points. Capsular enthesophytes were seen radiographically in injured limbs. Articular cartilage damage was demonstrated arthroscopically as mild wear-lines and histologically as superficial zone chondrocyte death accompanied by mild proliferation. Synovial hyperemia and fibrosis were present at the site of OC injury. Acute OC injury to the MCP joint resulted in clinical, imaging, and histologic changes in cartilage and synovium characteristic of early PTOA. This model will be useful for defining biomarkers of early osteoarthritis and for monitoring response to therapy and surgery. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  14. Effect of Strain Rate on Joint Strength and Failure Mode of Lead-Free Solder Joints

    NASA Astrophysics Data System (ADS)

    Lin, Jian; Lei, Yongping; Fu, Hanguang; Guo, Fu

    2018-03-01

    In surface mount technology, the Sn-3.0Ag-0.5Cu solder joint has a shorter impact lifetime than a traditional lead-tin solder joint. In order to improve the impact property of SnAgCu lead-free solder joints and identify the effect of silver content on tensile strength and impact property, impact experiments were conducted at various strain rates on three selected SnAgCu based solder joints. It was found that joint failure mainly occurred in the solder material with large plastic deformation under low strain rate, while joint failure occurred at the brittle intermetallic compound layer without any plastic deformation at a high strain rate. Joint strength increased with the silver content in SnAgCu alloys in static tensile tests, while the impact property of the solder joint decreased with increasing silver content. When the strain rate was low, plastic deformation occurred with failure and the tensile strength of the Sn-3.0Ag-0.5Cu solder joint was higher than that of Sn-0.3Ag-0.7Cu; when the strain rate was high, joint failure mainly occurred at the brittle interface layer and the Sn-0.3Ag-0.7Cu solder joint had a better impact resistance with a thinner intermetallic compound layer.

  15. The Joint Master Operational Planner

    DTIC Science & Technology

    2016-04-04

    Daniel H. Hibner, United States Army Joint Forces Staff College Joint Advanced Warfighting School 7800 Hampton Blvd. Norfolk, VA 23511-1702 Approved...Operational Art. Unclass Unclass Unclass Unclassified Unlimited 66 757-443-6301 NATIONAL DEFENSE UNIVERSITY JOINT FORCES STAFF COLLEGE JOINT ADVANCED...of this paper reflect my own personal views and are not necessarily endorsed by the Joint Forces Staff College or the department of Defense. Thesis

  16. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

    PubMed

    Bellmann, Malte; Schmalz, Thomas; Blumentritt, Siegmar

    2010-04-01

    To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic camera system combined with 2 forceplates as well as a mobile spiroergometric system. The study was conducted in a gait laboratory. Subjects with unilateral transfemoral amputations (N=9; mobility grade, 3-4; age, 22-49y) were tested. Participants were fitted and tested with 4 different microprocessor-controlled knee joints. Static prosthetic alignment, time distance parameters, kinematic and kinetic data and metabolic energy consumption. Compared with the Hybrid Knee and the Adaptive 2, the C-Leg offers clear advantages in the provision of adequate swing phase flexion resistances and terminal extension damping during level walking at various speeds, especially at higher walking speeds. The Rheo Knee provides sufficient terminal extension; however, swing phase flexion resistances seem to be too low. The values for metabolic energy consumption show only slight differences during level walking. The joint resistances generated for descending stairs and ramps relieve the contralateral side to varying degrees. When walking on stairs, safety-relevant technical differences between the investigated joint types can be observed. Designs with adequate internal resistances offer stability advantages when the foot is positioned on the step. Stumble recovery tests reveal that the different knee joint designs vary in their effectiveness in preventing the patient from falling. The patient benefits provided by the investigated electronic prosthetic knee joints differ considerably. The C-Leg appears to offer the amputee greater functional and safety-related advantages than the other tested knee joints. Reduced

  17. Cellular Pressure-Actuated Joint

    NASA Technical Reports Server (NTRS)

    McGuire, John R.

    2003-01-01

    A modification of a pressure-actuated joint has been proposed to improve its pressure actuation in such a manner as to reduce the potential for leakage of the pressurizing fluid. The specific joint for which the modification is proposed is a field joint in a reusable solid-fuel rocket motor (RSRM), in which the pressurizing fluid is a mixture of hot combustion gases. The proposed modification could also be applicable to other pressure-actuated joints of similar configuration.

  18. Mechanics of Suture Joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team

    2011-03-01

    Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.

  19. Health care joint ventures between tax-exempt organizations and for-profit entities.

    PubMed

    Sanders, Michael I

    2005-01-01

    Health care exempt organizations have many options regarding their structure and affiliations with for-profit entities. As long as any joint ventures are carefully structured and the nonprofit retains control over the exempt health care activities, the Internal Revenue Service should not question the structure. However, as outlined above, if the for-profit entity effectively gains control over the activities of the venture, the structure is not likely to be upheld by the IRS or the courts, and either the exempt status of the nonprofit will be denied or revoked, or health care income will be subject to the unrelated business income tax. In summary, the health care industry has been severely impacted by many economic forces, including uncertainty in the area of joint ventures between nonprofits and for-profit health care systems. The uncertainty as to whether the joint venture would negatively impact the nonprofit's tax-exempt status undoubtedly caused many nonprofits to form for-profit subsidiaries and otherwise expanded operations in a for-profit marketplace. Fortunately, with the guidance that is currently available in the form of Revenue Ruling 98-15, Redlands, St. David's, and now Revenue Ruling 2004-51, health care institutions can move forward with properly structured joint ventures with greater confidence that the joint venture will not endanger the tax-exempt status of the nonprofit.

  20. Generalised joint hypermobility and knee joint hypermobility: prevalence, knee joint symptoms and health-related quality of life in a Danish adult population.

    PubMed

    Junge, Tina; Henriksen, Peter; Hansen, Sebrina; Østengaard, Lasse; Golightly, Yvonne M; Juul-Kristensen, Birgit

    2017-10-27

    Several biomechanical factors, such as knee joint hypermobility (KJH), are suggested to play a role in the etiology of knee joint symptoms and knee osteoarthritis. Nevertheless, the prevalence or consequences of KJH solely or included in the classification of generalized joint hypermobility (GJHk) is unknown for a general population. Therefore, the objectives were to report the prevalence of self-reported GJHk and KJH, as well as the association of these conditions to knee joint symptoms, severity and duration of symptoms, and health-related quality of life (HRQoL) in a Danish adult population. This study is a cross-sectional population-based survey of 2056 Danish adults. Respondents received online questionnaires of GJHk and KJH, knee joint symptoms, the severity and duration of these, as well as HRQoL. Total response rate was 49% (n = 1006). The prevalence of self-reported GJHk and KJH was 13% and 23%, mostly representing women. More than half of the respondents with GJHk and KJH had knee joint symptoms. The odds for reporting knee joint symptoms, severity of knee joint symptoms and duration of knee joint symptoms were twice as high for respondents with GJHk and KJH. Respondents with GJHk and KJH reported lower HRQoL. GJHk and KJH were frequently reported in the Danish adult population, mostly in women. Respondents with GJHk and KJH were two times more likely to report knee joint-related symptoms such as pain, reduced performance of usual activity and lower HRQoL. The impact of these conditions on HRQoL is comparable with knee osteoarthritis. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  1. Influence of ankle joint plantarflexion and dorsiflexion on lateral ankle sprain: A computational study.

    PubMed

    Purevsuren, Tserenchimed; Kim, Kyungsoo; Batbaatar, Myagmarbayar; Lee, SuKyoung; Kim, Yoon Hyuk

    2018-05-01

    Understanding the mechanism of injury involved in lateral ankle sprain is essential to prevent injury, to establish surgical repair and reconstruction, and to plan reliable rehabilitation protocols. Most studies for lateral ankle sprain posit that ankle inversion, internal rotation, and plantarflexion are involved in the mechanism of injury. However, recent studies indicated that ankle dorsiflexion also plays an important role in the lateral ankle sprain mechanism. In this study, the contributions of ankle plantarflexion and dorsiflexion on the ankle joint were evaluated under complex combinations of internal and inversion moments. A multibody ankle joint model including 24 ligaments was developed and validated against two experimental cadaveric studies. The effects of ankle plantarflexion (up to 60°) and dorsiflexion (up to 30°) on the lateral ankle sprain mechanism under ankle inversion moment coupled with internal rotational moment were investigated using the validated model. Lateral ankle sprain injuries can occur during ankle dorsiflexion, in which the calcaneofibular ligament and anterior talofibular ligament tears may occur associated with excessive inversion and internal rotational moment, respectively. Various combinations of inversion and internal moment may lead to anterior talofibular ligament injuries at early ankle plantarflexion, while the inversion moment acts as a primary factor to tear the anterior talofibular ligament in early plantarflexion. It is better to consider inversion and internal rotation as primary factors of the lateral ankle sprain mechanism, while plantarflexion or dorsiflexion can be secondary factor. This information will help to clarify the lateral ankle sprain mechanism of injury.

  2. Ipsilateral Closed Clavicle and Scapular spine Fracture with Acromioclavicular Joint Disruption.

    PubMed

    Kembhavi, Raghavendra S; James, Boblee

    2015-01-01

    Injuries around shoulder and clavicle are quite common. Injuries involving lateral end of clavicle involving acromioclavicular joints are commoner injuries. In this rare injury, we report about a case involving clavicle and scapular spine fracture with acromioclavicular disruption which has never been described in English literature as per our knowledge. A patient with closed clavicle and scapular spine fracture with acromioclavicular joint disruption was treated with open reduction and internal fixation of clavicle and scapular spine as a staged procedures. Six months post operatively, patient had excellent functional recovery with near full range of movements. Though rare complex injury, clavicle fracture with scapular spine fracture with acromioclavicular disruption, when managed properly with good physiotherapy protocol post operatively will result in good clinical and functional outcome.

  3. Padalka and Polansky in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007430 (21 July 2009) --- Astronaut Mark Polansky (right) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  4. Polansky and Padalka in the Node 1 during Joint Operations

    NASA Image and Video Library

    2009-07-21

    S127-E-007453 (21 July 2009) --- Astronaut Mark Polansky (left) and Russian Federal Space Agency cosmonaut Gennady Padalka take a break from a busy agenda onboard the International Space Station on the eve of the third of five spacewalks scheduled as part of more than a week's worth of joint activities for Endeavour and ISS crewmembers. Polansky is STS-127 commander, and Padalka is the station commander.

  5. Joint Force Quarterly. Issue 74, 3rd Quarter, July 2014

    DTIC Science & Technology

    2014-07-01

    staging base USS Ponce during International Mine Countermeasures Exercise 13 (DOD/T. Scot Cregan) 16 Forum / Contexts of Future Conflict and War JFQ 74...perspective. Evolution According to David L. Woods in A History of Tactical Communication Techniques, “Since wars began, com- manders have sought...coalition personnel to meet the dynamic joint interoperability challenges within the MTN after nearly four decades. JFQ Notes 1 David L. Woods , A

  6. International Criminal Court Cases in Africa: Status and Policy Issues

    DTIC Science & Technology

    2009-07-14

    court, such as the one established for Sierra Leone.31 These courts and tribunals are distinct from the ICC. International Court of Justice The...African International Courts and Tribunals” website, at http://www.aict-cita.org. 31 The Special Court for Sierra Leone (SCSL), a hybrid international...domestic court based in Sierra Leone’s capital, Freetown, was set up jointly by the Government of Sierra Leone and the United Nations under Security

  7. Joint sparse reconstruction of multi-contrast MRI images with graph based redundant wavelet transform.

    PubMed

    Lai, Zongying; Zhang, Xinlin; Guo, Di; Du, Xiaofeng; Yang, Yonggui; Guo, Gang; Chen, Zhong; Qu, Xiaobo

    2018-05-03

    Multi-contrast images in magnetic resonance imaging (MRI) provide abundant contrast information reflecting the characteristics of the internal tissues of human bodies, and thus have been widely utilized in clinical diagnosis. However, long acquisition time limits the application of multi-contrast MRI. One efficient way to accelerate data acquisition is to under-sample the k-space data and then reconstruct images with sparsity constraint. However, images are compromised at high acceleration factor if images are reconstructed individually. We aim to improve the images with a jointly sparse reconstruction and Graph-based redundant wavelet transform (GBRWT). First, a sparsifying transform, GBRWT, is trained to reflect the similarity of tissue structures in multi-contrast images. Second, joint multi-contrast image reconstruction is formulated as a ℓ 2, 1 norm optimization problem under GBRWT representations. Third, the optimization problem is numerically solved using a derived alternating direction method. Experimental results in synthetic and in vivo MRI data demonstrate that the proposed joint reconstruction method can achieve lower reconstruction errors and better preserve image structures than the compared joint reconstruction methods. Besides, the proposed method outperforms single image reconstruction with joint sparsity constraint of multi-contrast images. The proposed method explores the joint sparsity of multi-contrast MRI images under graph-based redundant wavelet transform and realizes joint sparse reconstruction of multi-contrast images. Experiment demonstrate that the proposed method outperforms the compared joint reconstruction methods as well as individual reconstructions. With this high quality image reconstruction method, it is possible to achieve the high acceleration factors by exploring the complementary information provided by multi-contrast MRI.

  8. The Interface of Mechanics and Nociception in Joint Pathophysiology: Insights From the Facet and Temporomandibular Joints

    PubMed Central

    Sperry, Megan M.; Ita, Meagan E.; Kartha, Sonia; Zhang, Sijia; Yu, Ya-Hsin; Winkelstein, Beth

    2017-01-01

    Chronic joint pain is a widespread problem that frequently occurs with aging and trauma. Pain occurs most often in synovial joints, the body's load bearing joints. The mechanical and molecular mechanisms contributing to synovial joint pain are reviewed using two examples, the cervical spinal facet joints and the temporomandibular joint (TMJ). Although much work has focused on the macroscale mechanics of joints in health and disease, the combined influence of tissue mechanics, molecular processes, and nociception in joint pain has only recently become a focus. Trauma and repeated loading can induce structural and biochemical changes in joints, altering their microenvironment and modifying the biomechanics of their constitutive tissues, which themselves are innervated. Peripheral pain sensors can become activated in response to changes in the joint microenvironment and relay pain signals to the spinal cord and brain where pain is processed and perceived. In some cases, pain circuitry is permanently changed, which may be a potential mechanism for sustained joint pain. However, it is most likely that alterations in both the joint microenvironment and the central nervous system (CNS) contribute to chronic pain. As such, the challenge of treating joint pain and degeneration is temporally and spatially complicated. This review summarizes anatomy, physiology, and pathophysiology of these joints and the sensory pain relays. Pain pathways are postulated to be sensitized by many factors, including degeneration and biochemical priming, with effects on thresholds for mechanical injury and/or dysfunction. Initiators of joint pain are discussed in the context of clinical challenges including the diagnosis and treatment of pain. PMID:28056123

  9. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis

    PubMed Central

    Kim, Ha Yong; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-01-01

    Background The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Methods Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (Pf) and tibial coronal plane (Pt), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (Pf and Pt) during normal gait. Results With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Conclusions Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints. PMID:26330951

  10. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis.

    PubMed

    Kim, Ha Yong; Kim, Kap Jung; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-09-01

    The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (P f ) and tibial coronal plane (P t ), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (P f and P t ) during normal gait. With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints.

  11. 76 FR 5227 - Joint Industry Plan; Notice of Filing and Immediate Effectiveness of Amendment No. 24 to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    ... Organization Plan Governing the Collection, Consolidation and Dissemination of Quotation and Transaction...., EDGA Exchange, Inc., EDGX Exchange, Inc., Financial Industry Regulatory Authority, Inc., International... Joint Self- [[Page 5228

  12. Strength Variation of Parachute Joints

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    A parachute joint is defined as a location where a component is sewn or connected to another component. During the design and developmental phase of a parachute system, the joints for each structural component are isolated and tested through a process called seam and joint testing. The objective of seam and joint testing is to determine the degradation on a single component due to interaction with other components; this data is then used when calculating the margin of safety for that component. During the engineering developmental phase of CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, testing was completed for every joint of the six subsystems: the four parachutes (main, drogue, pilot, and FBCP [forward bay cover parachute]), the retention release bridle, and the retention panels. The number of joint tests for these subsystems totaled 92, which provides a plethora of data and results for further analysis. In this paper, the data and results of these seam and joint tests are examined to determine the effects, if any, of different operators and sewing machines on the strength of parachute joints. Other variables are also studied to determine their effect on joint strength, such as joint complexity, joint strength magnitude, material type, and material construction. Findings reveal that an optimally-run seam and joint test program could result in an increased understanding of the structure of the parachute; this should lead to a parachute built with optimal components, potentially saving system weight and volume.

  13. Official Positions for FRAX® clinical regarding international differences from Joint Official Positions Development Conference of the International Society for Clinical Densitometry and International Osteoporosis Foundation on FRAX®.

    PubMed

    Cauley, Jane A; El-Hajj Fuleihan, Ghada; Arabi, Asma; Fujiwara, Saeko; Ragi-Eis, Sergio; Calderon, Andrew; Chionh, Siok Bee; Chen, Zhao; Curtis, Jeffrey R; Danielson, Michelle E; Hanley, David A; Kroger, Heikki; Kung, Annie W C; Lesnyak, Olga; Nieves, Jeri; Pluskiewicz, Wojciech; El Rassi, Rola; Silverman, Stuart; Schott, Anne-Marie; Rizzoli, Rene; Luckey, Marjorie

    2011-01-01

    Osteoporosis is a serious worldwide epidemic. Increased risk of fractures is the hallmark of the disease and is associated with increased morbidity, mortality and economic burden. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors, femoral neck BMD, country specific mortality and fracture data and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator at the time paper was accepted for publication. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. In order to provide additional guidance to clinicians, a FRAX® International Task Force was formed to address specific questions raised by physicians in countries without FRAX® calculators and seeking to integrate FRAX® into their clinical practice. The main questions that the task force tried to answer were the following: The Task Force members conducted appropriate literature reviews and developed preliminary statements that were discussed and graded by a panel of experts at the ISCD-IOF joint conference. The statements approved by the panel of experts are discussed in the current paper. Copyright © 2011. Published by Elsevier Inc.

  14. Exploring the relationships between International Classification of Functioning, Disability and Health (ICF) constructs of Impairment, Activity Limitation and Participation Restriction in people with osteoarthritis prior to joint replacement.

    PubMed

    Pollard, Beth; Johnston, Marie; Dieppe, Paul

    2011-05-16

    The International Classification of Functioning, Disability and Health (ICF) proposes three main constructs, impairment (I), activity limitation (A) and participation restriction (P). The ICF model allows for all paths between the constructs to be explored, with significant paths likely to vary for different conditions. The relationships between I, A and P have been explored in some conditions but not previously in people with osteoarthritis prior to joint replacement. The aim of this paper is to examine these relationships using separate measures of each construct and structural equation modelling. A geographical cohort of 413 patients with osteoarthritis about to undergo hip and knee joint replacement completed the Aberdeen measures of Impairment, Activity Limitation and Participation Restriction (Ab-IAP). Confirmatory factor analysis was used to test the three factor (I, A, P) measurement model. Structural equation modelling was used to explore the I, A and P pathways in the ICF model. There was support from confirmatory factor analysis for the three factor I, A, P measurement model. The structural equation model had good fit [S-B Chi-square = 439.45, df = 149, CFI robust = 0.91, RMSEA robust = 0.07] and indicated significant pathways between I and A (standardised coefficient = 0.76 p < 0.0001) and between A and P (standardised coefficient = 0.75 p < 0.0001). However, the path between I and P was not significant (standardised coefficient = 0.01). The significant pathways suggest that treatments and interventions aimed at reducing impairment, such as joint replacement, may only affect P indirectly, through A, however, longitudinal data would be needed to establish this.

  15. Joint Enrollment Report, 2014

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2014

    2014-01-01

    The Iowa Department of Education collects information on joint enrollment in Iowa's 15 community colleges. Jointly enrolled students are high school students enrolled in community college credit coursework. Most jointly enrolled students enroll through Senior Year Plus (SYP) programs such as Postsecondary Enrollment Options (PSEO) and concurrent…

  16. Joint Enrollment Report, 2015

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2015

    2015-01-01

    The Iowa Department of Education collects information on joint enrollment from Iowa's 15 community colleges. Jointly enrolled students are high school students enrolled in community college credit coursework. Most jointly enrolled students enroll through Senior Year Plus programs such as Postsecondary Enrollment Options (PSEO) and concurrent…

  17. Migrating lumbar facet joint cysts.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-04-01

    The majority of lumbar facet joint cysts (LFJCs) are located in the spinal canal, on the medial aspect of the facet joint with characteristic diagnostic features. When they migrate away from the joint of origin, they cause diagnostic problems. In a 7-year period we examined by computed tomography (CT) and magnetic resonance (MR) imaging five unusual cases of facet joint cysts which migrated from the facet joint of origin. Three LFJCs were identified in the right S1 foramen, one in the right L5-S1 neural foramen and one in the left erector spinae and multifidus muscles between the levels of L2-L4 spinous process. Awareness that spinal lesions identified at MRI and CT could be due to migrating facet joint cyst requires a high level of suspicion. The identification of the appositional contact of the cyst and the facet joint needs to be actively sought in the presence of degenerative facet joints.

  18. Joint Chiefs of Staff > Directorates > J7 | Joint Force Development

    Science.gov Websites

    development: Doctrine, Education, Concept Development & Experimentation, Training, Exercises and Lessons Coalition Partners. Joint Education Develop policies governing officer and enlisted Joint Professional Military Education (JPME), and the National Defense University. Direct JPME educational advisory group and

  19. 3-D Analysis of Flanged Joints Through Various Preload Methods Using ANSYS

    NASA Astrophysics Data System (ADS)

    Murugan, Jeyaraj Paul; Kurian, Thomas; Jayaprakash, Janardhan; Sreedharapanickar, Somanath

    2015-10-01

    Flanged joints are being employed in aerospace solid rocket motor hardware for the integration of various systems or subsystems. Hence, the design of flanged joints is very important in ensuring the integrity of motor while functioning. As these joints are subjected to higher loads due to internal pressure acting inside the motor chamber, an appropriate preload is required to be applied in this joint before subjecting it to the external load. Preload, also known as clamp load, is applied on the fastener and helps to hold the mating flanges together. Generally preload is simulated as a thermal load and the exact preload is obtained through number of iterations. Infact, more iterations are required when considering the material nonlinearity of the bolt. This way of simulation will take more computational time for generating the required preload. Now a days most commercial software packages use pretension elements for simulating the preload. This element does not require iterations for inducing the preload and it can be solved with single iteration. This approach takes less computational time and thus one can study the characteristics of the joint easily by varying the preload. When the structure contains more number of joints with different sizes of fasteners, pretension elements can be used compared to thermal load approach for simulating each size of fastener. This paper covers the details of analyses carried out simulating the preload through various options viz., preload through thermal, initial state command and pretension element etc. using ANSYS finite element package.

  20. Effects of joints in truss structures

    NASA Technical Reports Server (NTRS)

    Ikegami, R.

    1988-01-01

    The response of truss-type structures for future space applications, such as Large Deployable Reflector (LDR), will be directly affected by joint performance. Some of the objectives of research at BAC were to characterize structural joints, establish analytical approaches that incorporate joint characteristics, and experimentally establish the validity of the analytical approaches. The test approach to characterize joints for both erectable and deployable-type structures was based upon a Force State Mapping Technique. The approach pictorially shows how the nonlinear joint results can be used for equivalent linear analysis. Testing of the Space Station joints developed at LaRC (a hinged joint at 2 Hz and a clevis joint at 2 Hz) successfully revealed the nonlinear characteristics of the joints. The Space Station joints were effectively linear when loaded to plus or minus 500 pounds with a corresponding displacement of about plus or minus 0.0015 inch. It was indicated that good linear joints exist which are compatible with errected structures, but that difficulty may be encountered if nonlinear-type joints are incorporated in the structure.

  1. Culture - joint fluid

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003742.htm Culture - joint fluid To use the sharing features on this page, please enable JavaScript. Joint fluid culture is a laboratory test to detect infection-causing ...

  2. Joint Chiefs of Staff > About > Joint Staff Inspector General

    Science.gov Websites

    DD Form 2949, Joint Inspector General Action Request (available at the link below). However, if you action if you intentionally make false statements. When you sign a DD Form 2949, you are signing a . DD Form 2949, Joint Inspector General Action Request Click here to expand content Click here to

  3. Ceramic joints

    DOEpatents

    Miller, Bradley J.; Patten, Jr., Donald O.

    1991-01-01

    Butt joints between materials having different coefficients of thermal expansion are prepared having a reduced probability of failure of stress facture. This is accomplished by narrowing/tapering the material having the lower coefficient of thermal expansion in a direction away from the joint interface and not joining the narrow-tapered surface to the material having the higher coefficient of thermal expansion.

  4. Sacroiliac joint dysfunction.

    PubMed

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  5. Cytokine mRNA expression in synovial fluid of affected and contralateral stifle joints and the left shoulder joint in dogs with unilateral disease of the stifle joint.

    PubMed

    de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Duchateau, Luc; Cox, Eric

    2007-09-01

    To examine mRNA expression of cytokines in synovial fluid (SF) cells from dogs with cranial cruciate ligament (CrCL) rupture and medial patellar luxation (MPL) and determine mRNA expression for 3 joints (affected stifle, unaffected contralateral stifle, and left shoulder joints) in dogs with unilateral CrCL rupture. 29 stifle joints with CrCL rupture (29 dogs), 8 stifle joints with MPL (7 dogs), and 24 normal stifle joints (16 clinically normal dogs). Immediately before reconstructive surgery, SF was aspirated from the cruciate-deficient stifle joint or stifle joint with MPL. Fourteen of 29 dogs had unilateral CrCL rupture; SF was also aspirated from the unaffected contralateral stifle joint and left shoulder joint. Those 14 dogs were examined 6 and 12 months after reconstructive surgery. Total RNA was extracted from SF cells and reverse transcription-PCR assay was performed to obtain cDNA. Canine-specific cytokine mRNA expression was determined by use of a real-time PCR assay. Interleukin (IL)-8 and -10 and interferon-gamma expression differed significantly between dogs with arthropathies and dogs with normal stifle joints. For the 14 dogs with unilateral CrCL rupture, a significant difference was found for IL-8 expression. Before reconstructive surgery, IL-8 expression differed significantly between the affected stifle joint and left shoulder joint or contralateral stifle joint. Six months after surgery, IL-8 expression was significantly increased in the unaffected contralateral stifle joint, compared with the shoulder joint. No conclusions can be made regarding the role of the examined cytokines in initiation of CrCL disease.

  6. Hip joint injection

    MedlinePlus

    ... medicine into the joint. The provider uses a real-time x-ray (fluoroscopy) to see where to place ... Wakefield RJ. Arthrocentesis and injection of joints and soft tissue. In: Firestein GS, Budd RC, Gabriel SE, ...

  7. Coherence between harvest and habitat management -- Joint venture perspectives

    USGS Publications Warehouse

    Baxter, C.K.; Nelson, J.W.; Reinecke, K.J.; Stephens, S.E.

    2006-01-01

    Introduction: In recent months, an ad hoc group of waterfowl scientists, representing the International Association of Fish and Wildlife Agencies (IAFWA) Adaptive Harvest Management (ARM) Task Force and the North American Waterfowl Management Plan (NAWMP) Committee, have collaborated as a Joint Task Group (JTG) to assess options for unifying the population goals guiding waterfowl harvest management and habitat management. The JTG has been charged with bringing coherence to the population goals of the two programs. Characterizing the problem as one of coherence indicates value judgments exist regarding its significance or perhaps existence. For purposes of this paper, we characterize the lack of coherence as the absence of consistent population goals in the two related components of waterfowl conservation habitat and harvest management. Our purpose is to support continued dialogue on the respective goals of these programs and the possible implications of discordant goals to habitat joint ventures. Our objectives are two-fold: (1) illustrate how NAWMP habitat management goals and strategies have been interpreted and pursued in both breeding and wintering areas, and (2) provide perspectives on the linkages between regional habitat management programs and harvest management. The Lower Mississippi Valley and the Prairie Pothole joint ventures (LMVJV and PPJV, respectively) will be used as examples.

  8. Sex Differences in Proximal Control of the Knee Joint

    PubMed Central

    Mendiguchia, Jurdan; Ford, Kevin R.; Quatman, Carmen E.; Alentorn-Geli, Eduard; Hewett, Timothy E.

    2014-01-01

    Following the onset of maturation, female athletes have a significantly higher risk for anterior cruciate ligament (ACL) injury compared with male athletes. While multiple sex differences in lower-extremity neuromuscular control and biomechanics have been identified as potential risk factors for ACL injury in females, the majority of these studies have focused specifically on the knee joint. However, increasing evidence in the literature indicates that lumbopelvic (core) control may have a large effect on knee-joint control and injury risk. This review examines the published evidence on the contributions of the trunk and hip to knee-joint control. Specifically, the sex differences in potential proximal controllers of the knee as risk factors for ACL injury are identified and discussed. Sex differences in trunk and hip biomechanics have been identified in all planes of motion (sagittal, coronal and transverse). Essentially, female athletes show greater lateral trunk displacement, altered trunk and hip flexion angles, greater ranges of trunk motion, and increased hip adduction and internal rotation during sport manoeuvres, compared with their male counterparts. These differences may increase the risk of ACL injury among female athletes. Prevention programmes targeted towards trunk and hip neuromuscular control may decrease the risk for ACL injuries. PMID:21688868

  9. Building an International Geosciences Network (i-GEON) for cyberinfrastructure-based Research and Education

    NASA Astrophysics Data System (ADS)

    Seber, D.; Baru, C.

    2007-05-01

    The Geosciences Network (GEON) project is a collaboration among multiple institutions to develop a cyberinfrastructure (CI) platform in support of integrative geoscience research activities. Taking advantage of the state-of-the-art information technology resources GEON researchers are building a cyberinfrastructure designed to enable data sharing, resource discovery, semantic data integration, high-end computations and 4D visualization in an easy-to-use web-based environment. The cyberinfrastructure in GEON is required to support an inherently distributed system, since the scientists, who are users as well as providers of resources, are themselves distributed. International collaborations are a natural extension of GEON; the geoscience research requires strong international collaborations. The goals of the i-GEON activities are to collaborate with international partners and jointly build a cyberinfrastructure for the geosciences to enable collaborative work environments. International partners can participate in GEON efforts, establish GEON nodes at their universities, institutes, or agencies and also contribute data and tools to the network. Via jointly run cyberinfrastructure workshops, the GEON team also introduces students, scientists, and research professionals to the concepts of IT-based geoscience research and education. Currently, joint activities are underway with the Chinese Academy of Sciences in China, the GEO Grid project at AIST in Japan, and the University of Hyderabad in India (where the activity is funded by the Indo-US Science and Technology Forum). Several other potential international partnerships are under consideration. iGEON is open to all international partners who are interested in working towards the goal of data sharing, managing and integration via IT-based platforms. Information about GEON and its international activities can be found at http:www.geongrid.org/

  10. Joint Aspiration (Arthrocentesis)

    MedlinePlus

    ... arthritis, or JRA), systemic lupus erythematosus (SLE), and Lyme disease. Joint aspiration is diagnostic but it also can ... topic for: Parents Kids Teens Evaluate Your Child's Lyme Disease Risk Living With Lupus Bones, Muscles, and Joints ...

  11. Longitudinal joint study.

    DOT National Transportation Integrated Search

    2001-09-01

    In previous years there has been a problem with longitudinal joint : deterioration, due in part to poor construction techniques. : The degradation of the longitudinal joints has increased the cost of : maintaining these projects and caused unnecessar...

  12. Joint Control for Dummies: An Elaboration of Lowenkron's Model of Joint (Stimulus) Control

    ERIC Educational Resources Information Center

    Sidener, David W.

    2006-01-01

    The following paper describes Lowenkron's model of joint (stimulus) control. Joint control is described as a means of accounting for performances, especially generalized performances, for which a history of contingency control does not provide an adequate account. Examples are provided to illustrate instances in which joint control may facilitate…

  13. Sacroiliac joint involvement in systemic sclerosis.

    PubMed

    Arslan Tas, Didem; Yıldız, Fatih; Sakallı, Hakan; Kelle, Bayram; Ballı, Tuğsan; Erken, Eren

    2015-01-01

    One of the major problems for systemic sclerosis (SSc) patients is suggested to be articular involvement. Mostly involved joints in SSc were reported as wrist, carpometacarpal-interphalangeal, foot, knee, hip and shoulder; however, there has been little knowledge on the sacroiliac joint. Our aim was to evaluate sacroiliac joint involvement in SSc. Fifty-seven SSc patients, 54 rheumatoid arthritis patients and 64 healthy subjects were included. Anteroposterior pelvic radiographs were obtained and graded twice by three blinded rheumatologists. One competent radiologist has re-evaluated the X-ray results. The ASAS (Assessment of Spondylo Arthritis International Society) scoring method was applied for grading sacroiliac involvement. Inflammatory back pain was also evaluated. Other clinical and laboratory data were collected as proposed by the European Study Group. In the SSc group sacroiliitis was found in 13 patients (23%) and was significantly different from RA patients (two patients, 4%), P = 0.003; and the healthy control group (one participant, 2%), P < 0.001. The frequency of inflammatory back pain in SSc patients with sacroiliitis (8/13 patients, 62%) was significantly higher in SSc patients without sacroiliitis (4/44 patients, 9%), P < 0.001. The SSc patients with sacroiliitis and with inflammatory back pain (8/57 patients, 14%) were regarded as axial spondyloarthritis overlap. Male gender, diffuse subtype, inflammatory back pain and high C-reactive protein levels (odds ratio: 1.069, 1.059, 1.059 and 3.698, respectively) were found to be the significant risk factors for sacroiliitis. We suggest that, sacroiliitis may be a concern to be considered in SSc practice. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  14. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  15. International Space Station Research for the Next Decade: International Coordination and Research Accomplishments

    NASA Technical Reports Server (NTRS)

    Thumm, Tracy L.; Robinson, Julie A.; Johnson-Green, Perry; Buckley, Nicole; Karabadzhak, George; Nakamura, Tai; Sorokin, Igor V.; Zell, Martin; Sabbagh, Jean

    2011-01-01

    During 2011, the International Space Station reached an important milestone in the completion of assembly and the shift to the focus on a full and continuous utilization mission in space. The ISS partnership itself has also met a milestone in the coordination and cooperation of utilization activities including research, technology development and education. We plan and track all ISS utilization activities jointly and have structures in place to cooperate on common goals by sharing ISS assets and resources, and extend the impacts and efficiency of utilization activities. The basic utilization areas on the ISS include research, technology development and testing, and education/outreach. Research can be categorized as applied research for future exploration, basic research taking advantage of the microgravity and open space environment, and Industrial R&D / commercial research focused at industrial product development and improvement. Technology development activities range from testing of new spacecraft systems and materials to the use of ISS as an analogue for future exploration missions to destinations beyond Earth orbit. This presentation, made jointly by all ISS international partners, will highlight the ways that international cooperation in all of these areas is achieved, and the overall accomplishments that have come as well as future perspectives from the cooperation. Recently, the partnership has made special efforts to increase the coordination and impact of ISS utilization that has humanitarian benefits. In this context the paper will highlight tentative ISS utilization developments in the areas of Earth remote sensing, medical technology transfer, and education/outreach.

  16. Inferior or double joint spaces injection versus superior joint space injection for temporomandibular disorders: a systematic review and meta-analysis.

    PubMed

    Li, Chunjie; Zhang, Yifan; Lv, Jun; Shi, Zongdao

    2012-01-01

    To compare the effect and safety of inferior or double temporomandibular joint spaces drug injection versus superior temporomandibular joint space injection in the treatment of temporomandibular disorders. MEDLINE (via Ovid, 1948 to March 2011), CENTRAL (Issue 1, 2011), Embase (1984 to March 2011), CBM (1978 to March 2011), and World Health Organization International Clinical Trials Registry Platform were searched electronically; relevant journals as well as references of included studies were hand-searched for randomized controlled trials comparing effect or safety of inferior or double joint spaces drug injection technique with those of superior space injection technique. Risk of bias assessment with the tool recommended by Cochrane Collaboration, reporting quality assessment with CONSORT and data extraction, were carried out independently by 2 reviewers. Meta-analysis was delivered with RevMan 5.0.23. Four trials with 349 participants were included. All the included studies had moderate risk of bias. Meta-analysis showed that inferior or double spaces injection technique could significantly increase 2.88 mm more maximal mouth opening (P = .0001) and alleviate pain intensity in the temporomandibular area on average by 9.01 mm visual analog scale scores (P = .0001) compared with superior space injection technique, but could not markedly change synthesized clinical index (P = .05) in the short term; nevertheless, they showed more beneficial maximal mouth opening (P = .002), pain relief (P < .0001), and synthesized clinical variable (P < .0001) in the long term than superior space injection. No serious adverse events were reported. Inferior or double temporomandibular joint spaces drug injection technique shows better effect than superior space injection technique, and their safety is affirmative. However, more high-quality studies are still needed to test and verify the evidence. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  17. Joint Implications for Contracted Logistics

    DTIC Science & Technology

    2007-03-30

    authority with the host nation country and policy on using UCMJ for contracted personnel. As tailored theater policies are developed and contracting...responsibility, this paper recommends better joint training, leader development and joint enablers for contracting operations. JOINT...U.S. Joint Forces Command (JFCOM) are analyzing Congressional and DOD policy to develop procedures and force structure to support contractor

  18. Comparison of the use of notched wedge joints vs. traditional butt joints in Connecticut

    DOT National Transportation Integrated Search

    2008-11-07

    Performance of Hot Mix Asphalt (HMA) longitudinal joints have been an item of increasing scrutiny in : Connecticut. The traditional butt joint has typically been the method used in Connecticut. These joints : have been reportedly opening up, creating...

  19. Evaluation of narrow transverse contraction joints in jointed plain concrete pavements.

    DOT National Transportation Integrated Search

    2006-03-01

    This report presents the results of a research project conducted at the Louisiana Transportation Research Center (LTRC) to evaluate the performance of narrow transverse contraction joints to control cracking in jointed plain concrete pavements. In ad...

  20. Predicting tibiotalar and subtalar joint angles from skin-marker data with dual-fluoroscopy as a reference standard.

    PubMed

    Nichols, Jennifer A; Roach, Koren E; Fiorentino, Niccolo M; Anderson, Andrew E

    2016-09-01

    Evidence suggests that the tibiotalar and subtalar joints provide near six degree-of-freedom (DOF) motion. Yet, kinematic models frequently assume one DOF at each of these joints. In this study, we quantified the accuracy of kinematic models to predict joint angles at the tibiotalar and subtalar joints from skin-marker data. Models included 1 or 3 DOF at each joint. Ten asymptomatic subjects, screened for deformities, performed 1.0m/s treadmill walking and a balanced, single-leg heel-rise. Tibiotalar and subtalar joint angles calculated by inverse kinematics for the 1 and 3 DOF models were compared to those measured directly in vivo using dual-fluoroscopy. Results demonstrated that, for each activity, the average error in tibiotalar joint angles predicted by the 1 DOF model were significantly smaller than those predicted by the 3 DOF model for inversion/eversion and internal/external rotation. In contrast, neither model consistently demonstrated smaller errors when predicting subtalar joint angles. Additionally, neither model could accurately predict discrete angles for the tibiotalar and subtalar joints on a per-subject basis. Differences between model predictions and dual-fluoroscopy measurements were highly variable across subjects, with joint angle errors in at least one rotation direction surpassing 10° for 9 out of 10 subjects. Our results suggest that both the 1 and 3 DOF models can predict trends in tibiotalar joint angles on a limited basis. However, as currently implemented, neither model can predict discrete tibiotalar or subtalar joint angles for individual subjects. Inclusion of subject-specific attributes may improve the accuracy of these models. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. International Collaboration on Genomics of Economically Relevant Traits

    USDA-ARS?s Scientific Manuscript database

    An international collaboration is attempting to make better use of high density SNP information by combining each contributor’s results. The initial group of collaborators are from Australia (CRC for Beef Genetic Technologies), Canada (a joint contribution from the Universities of Alberta and Guelp...

  2. Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

    NASA Technical Reports Server (NTRS)

    Verhage, Joseph M.; Bower, Mark V.; Gilbert, Paul A. (Technical Monitor)

    2001-01-01

    The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

  3. Longitudinal joint treatment.

    DOT National Transportation Integrated Search

    2006-03-01

    Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...

  4. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  5. Effect of occlusal appliances and clenching on the internally deranged TMJ space.

    PubMed

    Kuboki, T; Takenami, Y; Orsini, M G; Maekawa, K; Yamashita, A; Azuma, Y; Clark, G T

    1999-01-01

    Stabilization appliances and mandibular anterior repositioning appliances have been used to treat patients with internal derangement of the temporomandibular joint (TMJ) based on the assumption that these appliances work by decompressing the TMJ. The purpose of this study was to indirectly test this assumption. Bilateral TMJ tomograms of 7 subjects with unilateral anterior disc displacement without reduction (ADDwor) were taken during comfortable closure and during maximum clenching in maximum intercuspation; tomograms were also taken with the 2 types of occlusal appliances in use. Outlines of the condyle and the temporal fossa were automatically determined by an edge-detection protocol, and the minimum joint space dimension of the joints with and without ADDwor was automatically measured for each experimental condition as the outcome variable. Upon comfortable closure and maximum clenching, the minimum joint space dimensions of the ipsilateral and contralateral joints with the use of stabilization appliances and mandibular anterior repositioning appliances were not significantly different from those seen in maximum intercuspation. These findings do not indicate that these appliances induce an increase in joint space during closing and clenching in joints with ADDwor.

  6. Novel Ultrasound Joint Selection Methods Using a Reduced Joint Number Demonstrate Inflammatory Improvement when Compared to Existing Methods and Disease Activity Score at 28 Joints.

    PubMed

    Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; D'Agostino, Maria Antonietta; Chew, Li-Ching; Thumboo, Julian

    2016-01-01

    A pilot study testing novel ultrasound (US) joint-selection methods in rheumatoid arthritis. Responsiveness of novel [individualized US (IUS) and individualized composite US (ICUS)] methods were compared with existing US methods and the Disease Activity Score at 28 joints (DAS28) for 12 patients followed for 3 months. IUS selected up to 7 and 12 most ultrasonographically inflamed joints, while ICUS additionally incorporated clinically symptomatic joints. The existing, IUS, and ICUS methods' standardized response means were -0.39, -1.08, and -1.11, respectively, for 7 joints; -0.49, -1.00, and -1.16, respectively, for 12 joints; and -0.94 for DAS28. Novel methods effectively demonstrate inflammatory improvement when compared with existing methods and DAS28.

  7. Accuracy of acromioclavicular joint injections.

    PubMed

    Wasserman, Bradley R; Pettrone, Sarah; Jazrawi, Laith M; Zuckerman, Joseph D; Rokito, Andrew S

    2013-01-01

    Injection to the acromioclavicular (AC) joint can be both diagnostic and therapeutic. The purpose of this study was to evaluate the accuracy of in vivo AC joint injections. Case series; Level of evidence, 4. Thirty patients with pain localized to the AC joint were injected with 1 mL of 1% lidocaine and 0.5 mL of radiographic contrast material (Isovue). Radiographs of the AC joint were taken after the injection. Each radiograph was reviewed by a musculoskeletal radiologist and graded as intra-articular, extra-articular, or partially intra-articular. Of the 30 injections performed, 13 (43.3%) were intra-articular, 7 (23.3%) were partially articular, and 10 (33.3%) were extra-articular. When the intra-articular and the partially articular groups were combined, 20 patients (66.7%) had some contrast dye in the AC joint. This study demonstrates that despite the relatively superficial location of the AC joint, the clinical accuracy of AC joint injections remains relatively low.

  8. Can symptomatic acromioclavicular joints be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging?

    PubMed

    Choo, Hye Jung; Lee, Sun Joo; Kim, Jung Han; Cha, Seong Sook; Park, Young Mi; Park, Ji Sung; Lee, Jun Woo; Oh, Minkyung

    2013-04-01

    To evaluate retrospectively whether symptomatic acromioclavicular joints can be differentiated from asymptomatic acromioclavicular joints on 3-T MR imaging. This study included 146 patients who underwent physical examination of acromioclavicular joints and 3-T MR imaging of the shoulder. Among them, 67 patients showing positive results on physical examination were assigned to the symptomatic group, whereas 79 showing negative results were assigned to the asymptomatic group. The following MR findings were compared between the symptomatic and asymptomatic groups: presence of osteophytes, articular surface irregularity, subchondral cysts, acromioclavicular joint fluid, subacromial fluid, subacromial bony spurs, joint capsular distension, bone edema, intraarticular enhancement, periarticular enhancement, superior and inferior joint capsular distension degree, and joint capsular thickness. The patients were subsequently divided into groups based on age (younger, older) and the method of MR arthrography (direct MR arthrography, indirect MR arthrography), and all the MR findings in each subgroup were reanalyzed. The meaningful cutoff value of each significant continuous variable was calculated using receiver operating characteristic analysis. The degree of superior capsular distension was the only significant MR finding of symptomatic acromioclavicular joints and its meaningful cutoff value was 2.1mm. After subgroup analyses, this variable was significant in the older age group and indirect MR arthrography group. On 3-T MR imaging, the degree of superior joint capsular distension might be a predictable MR finding in the diagnosis of symptomatic acromioclavicular joints. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Joint project of the international network of agencies for health technology assessment--Part 1: Survey results on diffusion, assessment, and clinical use of positron emission tomography.

    PubMed

    Hastings, John; Adams, Elizabeth J

    2006-01-01

    The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.

  10. [Effects of exercise on joints.

    PubMed

    Moriyama, Hideki

    Joints are composed of several different tissues(cartilage, capsule, meniscus, and ligament), and articular cartilage plays an important role in maintaining mechanical competence during exercise. Weight-bearing exercise has several benefit, including improved blood and synovial fluid circulation in a given joint. Consistent moderate activities facilitate cycles of anabolism and catabolism. Mechanical stresses are crucial for the maintenance of the morphologic and functional integrity of articular cartilage. Healthy cartilage is exposed by hydrostatic pressure and tensile strain, when cartilage degeneration develops, abnormal cartilage is exposed by shear stress. Moderate(physiological)exercise is characterized by a range of equilibrium between matrix anabolic and catabolic processes, or anabolism beyond catabolism. Joints are susceptible to insufficient or excessive activities, leading to joint degeneration. Lack of exercise is known to induce joint contracture seen clinically as a consequence of disuse changes, and excess mechanical stresses induce joint destruction such as osteoarthritis. Joint diseases resulting from insufficient or excessive activities are new and major challenging issues with our aging population. Thus, it is highly desirable to have an effective and efficient treatment to improve and protect against these joint diseases, and thereby to solve these clearly unanswered issues.

  11. A Practical Strategy for sEMG-Based Knee Joint Moment Estimation During Gait and Its Validation in Individuals With Cerebral Palsy

    PubMed Central

    Kwon, Suncheol; Stanley, Christopher J.; Kim, Jung; Kim, Jonghyun; Damiano, Diane L.

    2013-01-01

    Individuals with cerebral palsy have neurological deficits that may interfere with motor function and lead to abnormal walking patterns. It is important to know the joint moment generated by the patient’s muscles during walking in order to assist the suboptimal gait patterns. In this paper, we describe a practical strategy for estimating the internal moment of a knee joint from surface electromyography (sEMG) and knee joint angle measurements. This strategy requires only isokinetic knee flexion and extension tests to obtain a relationship between the sEMG and the knee internal moment, and it does not necessitate comprehensive laboratory calibration, which typically requires a 3-D motion capture system and ground reaction force plates. Four estimation models were considered based on different assumptions about the functions of the relevant muscles during the isokinetic tests and the stance phase of walking. The performance of the four models was evaluated by comparing the estimated moments with the gold standard internal moment calculated from inverse dynamics. The results indicate that an optimal estimation model can be chosen based on the degree of cocontraction. The estimation error of the chosen model is acceptable (normalized root-mean-squared error: 0.15–0.29, R: 0.71–0.93) compared to previous studies (Doorenbosch and Harlaar, 2003; Doorenbosch and Harlaar, 2004; Doorenbosch, Joosten, and Harlaar, 2005), and this strategy provides a simple and effective solution for estimating knee joint moment from sEMG. PMID:22410952

  12. Protection for the U.S. Automobile Industry: A Joint Class Simulation in Trade Policy.

    ERIC Educational Resources Information Center

    Hess, Peter N.; Ortmayer, Louis M.

    A description of a joint class simulation in trade policy undertaken by an international economics class and a political science class at Davidson College (Pennsylvania) is presented in three sections. Section I describes the structure of the simulation. Students were divided into groups of United States auto manufacturers, the United Auto…

  13. Gender-related differences in lower limb alignment, range of joint motion, and the incidence of sports injuries in Japanese university athletes.

    PubMed

    Mitani, Yasuhiro

    2017-01-01

    [Purpose] To investigate the gender-related differences in lower limb alignment, range of joint motion, and history of lower limb sports injuries in Japanese university athletes. [Subjects and Methods] The subjects were 224 Japanese university athletes (154 males and 70 females). The quadriceps angle (Q-angle), arch height index, and ranges of internal and external rotation of the hip joints were measured. History of lower limb sports injury was surveyed using a questionnaire. [Results] Females had a significantly higher Q-angle and hip joint internal rotation angle and a significantly lower arch height index than males. The survey revealed that a significantly higher proportion of females had a history of lower limb sports injuries, and that the proportion of those with a history of foot/ankle injuries was particularly high. [Conclusion] These results suggested that females experience more lower limb sports injuries than males, and that a large proportion of these injuries involve the foot/ankle. Reduced lower limb alignment and increased range of joint motion in females may be risk factors for injury because they lead to increased physical stress being exerted on the lower legs during sporting activities.

  14. [SOMATOTYPE JOINT MOBILITY AND RANGES OF HIP AND KNEE OF COLLEGE STUDENTS].

    PubMed

    Godoy-Cumillaf, Andrés; Valdés-Badilla, Pablo; García Sandoval, Alan; Grandón Fuentes, Monica; Lagos Del Canto, Loreto; Aravena Turra, Raúl; Herrera-Valenzuela, Tomás; Bruneau Chavez, José; Durán Agüero, Samuel

    2015-12-01

    several studies indicate a consistency between the physical inactivity and low levels of mobility in hip and knee joint. to determine the differences in the motion range of the hip and knee joint between the different classifications of somatotype in students of Pedagogy in Physical Education of the Universidad Autónoma de Chile, campus Temuco. the sample included 102 physical education students (31.3% female), somatotype was obtained through the protocol of the International Society for the Advancement of Kinanthropometry (ISAK) and the motion range of the hip and knee joint (ROM) using a universal goniometer. the mean somatotype was endo-mesomorphic (4.8 - 3.4 - 2) for the women and meso-endomorphic (3.5 - 5.7 - 2) for the males, while the ROM evaluation indicated that the 50% of the students presented mobility values of joint lower than the normal ones. Furthermore, the endo-mesomorphic women showed lower ROM values of medial rotation of the right hip (45.5 ° ± 10.2 °; P = 0.0125, t = 2.732) and left hip side rotation (41.7 ° ± 10.3 °; P = 0.0256; p = 2.402) than the women meso-endomorphic. the results shows a relationship between the somatotype and hip ROM in the women, showing that in the women the most favorable results of joint mobility are related with a greater muscle mass. In contrasts, no significant differences were observed in men. It is important to encourage the development of joint mobility exercises according to the specific needs of each sex. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  15. Load transfer in the stiffener-to-skin joints of a pressurized fuselage

    NASA Technical Reports Server (NTRS)

    Johnson, Eric R.; Rastogi, Naveen

    1995-01-01

    Structural analyses are developed to determine the linear elastic and the geometrically nonlinear elastic response of an internally pressurized, orthogonally stiffened, composite material cylindrical shell. The configuration is a long circular cylindrical shell stiffened on the inside by a regular arrangement of identical stringers and identical rings. Periodicity permits the analysis of a unit cell model consisting of a portion of the shell wall centered over one stringer-ring joint. The stringer-ring-shell joint is modeled in an idealized manner; the stiffeners are mathematically permitted to pass through one another without contact, but do interact indirectly through their mutual contact with the shell at the joint. Discrete beams models of the stiffeners include a stringer with a symmetrical cross section and a ring with either a symmetrical or an asymmetrical open section. Mathematical formulations presented for the linear response include the effect of transverse shear deformations and the effect of warping of the ring's cross section due to torsion. These effects are important when the ring has an asymmetrical cross section because the loss of symmetry in the problem results in torsion and out-of-plane bending of the ring, and a concomitant rotation of the joint at the stiffener intersection about the circumferential axis. Data from a composite material crown panel typical of a large transport fuselage structure are used for two numerical examples. Although the inclusion of geometric nonlinearity reduces the 'pillowing' of the shell, it is found that bending is localized to a narrow region near the stiffener. Including warping deformation of the ring into the analysis changes the sense of the joint rotation. Transverse shear deformation models result in increased joint flexibility.

  16. New Joint Sealants. Criteria, Design and Materials.

    ERIC Educational Resources Information Center

    Building Research Inst., Inc., Washington, DC.

    Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…

  17. Steroid injections - tendon, bursa, joint

    MedlinePlus

    ... a small amount of corticosteroid and a local anesthetic into the bursa. JOINT Any joint problem, such ... A small amount of corticosteroid and a local anesthetic will be injected into the joint. TENDON A ...

  18. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  19. [Classification and Treatment of Sacroiliac Joint Dislocation].

    PubMed

    Tan, Zhen; Huang, Zhong; Li, Liang; Meng, Wei-Kun; Liu, Lei; Zhang, Hui; Wang, Guang-Lin; Huang, Fu-Guo

    2017-09-01

    To develop a renewed classification and treatment regimen for sacroiliac joint dislocation. According to the direction of dislocation of sacroiliac joint,combined iliac,sacral fractures,and fracture morphology,sacroiliac joint dislocation was classified into 4 types. Type Ⅰ (sacroiliac anterior dislocation): main fracture fragments of posterior iliac wing dislocated in front of sacroiliac joint. Type Ⅱ (sacroiliac posterior dislocation): main fracture fragments of posterior iliac wing dislocated in posterior of sacroiliac joint. Type Ⅲ (Crescent fracturedislocation of the sacroiliac joint): upward dislocation of posterior iliac wing with oblique fracture through posterior iliac wing. Type ⅢA: a large crescent fragment and dislocation comprises no more than onethird of sacroiliac joint,which is typically inferior. Type ⅢB: intermediatesize crescent fragment and dislocation comprises between one and twothirds of joint. Type ⅢC: a small crescent fragment where dislocation comprises most,but not the entire joint. Different treatment regimens were selected for different types of fractures. Treatment for type Ⅰ sacroiliac joint dislocation: anterior iliac fossa approach pry stripping reset; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅱ sacroiliac joint dislocation: posterior sacroiliac joint posterior approach; sacroiliac joint fixed with sacroiliac screw under computer guidance. Treatment for type ⅢA and ⅢB sacroiliac joint dislocation: posterior sacroiliac joint approach; sacroiliac joint fixed with reconstruction plate. Treatment for type ⅢC sacroiliac joint dislocation: sacroiliac joint closed reduction; sacroiliac joint fixed with sacroiliac screw through percutaneous. Treatment for type Ⅳ sacroiliac joint dislocation: posterior approach; sacroiliac joint fixed with spinal pelvic fixation. Results of 24 to 72 months patient follow-up (mean 34.5 months): 100% survival,100% wound healing,and 100

  20. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, J.V.; Novak, R.F.; McBride, J.R.

    1991-08-27

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system. 11 figures.

  1. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, John V.; Novak, Robert F.; McBride, James R.

    1991-01-01

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system.

  2. International Space Station (ISS)

    NASA Image and Video Library

    2007-06-13

    STS-117 astronauts and mission specialists Patrick Forrester and Steven Swanson (out of frame), participated in the second Extra Vehicular Activity (EVA) as construction resumed on the International Space Station (ISS). Among other tasks, the two removed all of the launch locks holding the 10 foot wide solar alpha rotary joint in place and began the solar array retraction. The primary mission objective was the installment of the second and third starboard truss segments (S3 and S4).

  3. Sacroiliac joint tuberculosis

    PubMed Central

    Govender, S.

    2006-01-01

    Infections of the sacroiliac joint are uncommon and the diagnosis is usually delayed. In a retrospective study, 17 patients who had been treated for tuberculosis sacroiliitis between 1994 and 2004 were reviewed. Two patients were excluded due to a short follow-up (less than 2 years). Low back pain and difficulty in walking were the most common presenting features. Two patients presented with a buttock abscess and spondylitis of the lumbar spine was noted in two patients. The Gaenslen’s and FABER (flexion, abduction and external rotation) tests were positive in all patients. Radiological changes included loss of cortical margins with erosion of the joints. An open biopsy and curettage was performed in all patients; histology revealed chronic infection and acid-fast bacilli were isolated in nine patients. Antituberculous (TB) medication was administered for 18 months and the follow-up ranged from 3 to 10 years (mean: 5 years). The sacroiliac joint fused spontaneously within 2 years. Although all patients had mild discomfort in the lower back following treatment they had no difficulty in walking. Sacroiliac joint infection must be included in the differential diagnosis of lower back pain and meticulous history and clinical evaluation of the joint are essential. PMID:16673102

  4. Lower limb joint work and joint work contribution during downhill and uphill walking at different inclinations.

    PubMed

    Alexander, Nathalie; Strutzenberger, Gerda; Ameshofer, Lisa Maria; Schwameder, Hermann

    2017-08-16

    Work performance and individual joint contribution to total work are important information for creating training protocols, but were not assessed so far for sloped walking. Therefore, the purpose of this study was to analyze lower limb joint work and joint contribution of the hip, knee and ankle to total lower limb work during sloped walking in a healthy population. Eighteen male participants (27.0±4.7yrs, 1.80±0.05m, 74.5±8.2kg) walked on an instrumented ramp at inclination angles of 0°, ±6°, ±12° and ±18° at 1.1m/s. Kinematic and kinetic data were captured using a motion-capture system (Vicon) and two force plates (AMTI). Joint power curves, joint work (positive, negative, absolute) and each joint's contribution to total lower limb work were analyzed throughout the stance phase using an ANOVA with repeated measures. With increasing inclination positive joint work increased for the ankle and hip joint and in total during uphill walking. Negative joint work increased for each joint and in total work during downhill walking. Absolute work was increased during both uphill (all joints) and downhill (ankle & knee) walking. Knee joint contribution to total negative and absolute work increased during downhill walking while hip and ankle contributions decreased. This study identified, that, when switching from level to a 6° and from 6° to a 12° inclination the gain of individual joint work is more pronounced compared to switching from 12° to an 18° inclination. The results might be used for training recommendations and specific training intervention with respect to sloped walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. [Temporo-mandibular joint. Morpho-functional considerations].

    PubMed

    Scutariu, M D; Indrei, Anca

    2004-01-01

    The temporo-mandibular joint is distinguished from most other synovial joints of the body by two features: 1. the two jointed components carry teeth whose position and occlusion introduce a very strong influence on the movements of the temporo-mandibular joint and 2. its articular surfaces are not covered by hyaline cartilage, but by a dense, fibrous tissue. This paper describes the parts of the temporo-mandibular joint: the articular surfaces (the condylar process of the mandible and the glenoid part of the temporal bone), the fibrocartilaginous disc which is interposed between the mandibular and the temporal surface, the fibrous capsule of the temporo-mandibular joint and the ligaments of this joint. All these parts present a very strong adaptation at the important functions of the temporo-mandibular joint.

  6. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  7. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  8. Synovial chondromatosis of the temporomandibular joint: a case report and literature review.

    PubMed

    Reed, Lucas S; Foster, Michael D; Hudson, John W

    2013-10-01

    Synovial chondromatosis (SC) is a pathologic condition in which mesenchymal tissue rests in a given synovial membrane undergo a metaplastic process, ultimately producing and secreting cartilaginous bodies into the joint space. It is more commonly discussed in the orthopedic literature, since the axial skeleton is the most frequently affected. Although rare, it does occur within the temporomandibular joint (TMJ), with approximately 100 cases previously being described. Within the TMJ, its presentation can be variable, though most cases will show it to be unilateral with fixed and/or loose cartilaginous bodies confined to the superior joint space. Clinically, patients may present with symptoms similar to that of an internal derangement disorder, including pain, clicking, tenderness, functional limitations, and swelling. A thorough history and physical examination, along with proper radiographic examination, are paramount in properly diagnosing SC. Treatment options consist of arthroscopy, arthrotomy with synovectomy, excision of cartilaginous bodies, and possible discectomy. In the current paper, the authors describe the presentation, diagnosis, and surgical management of a SC case involving the right TMJ in a 31-year-old Caucasian female.

  9. Load Variation Influences on Joint Work During Squat Exercise in Reduced Gravity

    NASA Technical Reports Server (NTRS)

    DeWitt, John K.; Fincke, Renita S.; Logan, Rachel L.; Guilliams, Mark E.; Ploutz-Snyder, Lori L.

    2011-01-01

    Resistance exercises that load the axial skeleton, such as the parallel squat, are incorporated as a critical component of a space exercise program designed to maximize the stimuli for bone remodeling and muscle loading. Astronauts on the International Space Station perform regular resistance exercise using the Advanced Resistive Exercise Device (ARED). Squat exercises on Earth entail moving a portion of the body weight plus the added bar load, whereas in microgravity the body weight is 0, so all load must be applied via the bar. Crewmembers exercising in microgravity currently add approx.70% of their body weight to the bar load as compensation for the absence of the body weight. This level of body weight replacement (BWR) was determined by crewmember feedback and personal experience without any quantitative data. The purpose of this evaluation was to utilize computational simulation to determine the appropriate level of BWR in microgravity necessary to replicate lower extremity joint work during squat exercise in normal gravity based on joint work. We hypothesized that joint work would be positively related to BWR load.

  10. Design of foundations with sliding joint at areas affected with underground mining

    NASA Astrophysics Data System (ADS)

    Matečková, P.; Šmiřáková, M.; Maňásek, P.

    2018-04-01

    Underground mining always influences also landscape on surface. If there are buildings on the surface they are affected with terrain deformation which comprises terrain inclination, curvature, shift and horizontal deformation. Ostrava – Karvina region is specific with underground mining very close to densely inhabited area. About 25 years ago there were mines even in the city of Ostrava. Recommendations and rules for design of building structures at areas affected with underground mining have been therefore analysed in long term. This paper is focused on deformation action caused by terrain horizontal deformation - expansion or compression. Through the friction between foundation structure and subsoil in footing bottom the foundation structure has to resist significant normal forces. The idea of sliding joint which eliminates the friction and decreases internal forces comes from the last century. Sliding joint made of asphalt belt has been analysed at Faculty of Civil Engineering, VSB – Technical University of Ostrava in long term. The influence of vertical and horizontal load and the effect of temperature in temperature controlled room have been examined. Testing, design and utilization of sliding joint is presented.

  11. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  12. Improved TIG weld joint strength in aluminum alloy 2219-T87 by filler metal substitution

    NASA Technical Reports Server (NTRS)

    Poorman, R. M.; Lovoy, C. V.

    1972-01-01

    The results of an investigation on weld joint characteristics of aluminum alloy 2219-T87 are given. Five different alloys were utilized as filler material. The mechanical properties of the joints were determined at ambient and cryogenic temperatures for weldments in the as-welded condition and also, for weldments after elevated temperature exposures. Other evaluations included hardness surveys, stress corrosion susceptibility, and to a limited extent, the internal metallurgical weld structures. The overall results indicate that M-943 filler weldments are superior in strength to weldments containing either the standard 2319 filler or fillers 2014, 2020, and a dual wire feed consisting of three parts 2319 and one part 5652. In addition, no deficiencies were evident in M-934 filler weldments with regard to ductility, joint strength after elevated temperature exposure, weld hardness, metallographic structures, or stress corrosion susceptibility.

  13. Wrist joint assembly

    NASA Technical Reports Server (NTRS)

    Kersten, L.; Johnson, J. D. (Inventor)

    1978-01-01

    A wrist joint assembly is provided for use with a mechanical manipulator arm for finely positioning an end-effector carried by the wrist joint on the terminal end of the manipulator arm. The wrist joint assembly is pivotable about a first axis to produce a yaw motion, a second axis is to produce a pitch motion, and a third axis to produce a roll motion. The wrist joint assembly includes a disk segment affixed to the terminal end of the manipulator arm and a first housing member, a second housing member, and a third housing member. The third housing member and the mechanical end-effector are moved in the yaw, pitch, and roll motion. Drive means are provided for rotating each of the housings about their respective axis which includes a cluster of miniature motors having spur gears carried on the output drive shaft which mesh with a center drive gear affixed on the housing to be rotated.

  14. Value of tomosynthesis for lesion evaluation of small joints in osteoarthritic hands using the OARSI score.

    PubMed

    Martini, K; Becker, A S; Guggenberger, R; Andreisek, G; Frauenfelder, T

    2016-07-01

    To determine the diagnostic performance of tomosynthesis in depicting osteoarthritic lesions in comparison to conventional radiographs, with use of computed tomography (CT) as standard-of-reference. Imaging of 12 cadaveric hands was performed with tomosynthesis in dorso-palmar (dp) projection, conventional radiographs (dp) and multi-detector CT. Distal interphalangeal joint (DIP)II, DIPIII, proximal interphalangeal joint (PIP)II, PIPIII, first carpometacarpal (CMC) and scaphotrapezotrapezoidal joint (STT) were graded by two independent readers using the Osteoarthritis Research Society International (OARSI) score. The mean score for each feature was calculated for all modalities. Additional wrists were evaluated for presence of calcium pyrophosphate disease (CPPD). CT served as reference-standard. Inter-reader agreement (ICC) was calculated. Comparing tomosynthesis and conventional radiographs to CT, the sensitivity for the presence of osteophytes was 95,7% vs 65,2%; for joint space narrowing 95,8% vs 52,1%; for subchondral sclerosis 61,5% vs 51,3%; for lateral deformity 83.3% vs 83,3%; and for subchondral cysts 45,8% vs 29,2%. Erosions were not present. While tomosynthesis showed no significant difference in OARSI score grading to CT (mean OARSI-score CT: 16.8, SD = 10.6; mean OARSI-score Tomosynthesis: 16.3, SD = 9.6; P = 0.84), conventional radiographs had significant lower mean OARSI scores (mean OARSI-score X-ray: 11.1, SD = 8.3; P = 0.04). Inter-reader agreement for OARSI scoring was excellent (ICC = 0.99). CPPD calcifications present in CT, were also visible with tomosynthesis, but not with conventional radiography. In conclusion, tomosynthesis depicts more osteoarthritic changes in the small joints of the hand than conventional radiography using the OARSI scoring system and CT as the standard of reference. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Effects of prophylactic knee bracing on knee joint kinetics and kinematics during netball specific movements.

    PubMed

    Sinclair, Jonathan K; Vincent, Hayley; Richards, Jim D

    2017-01-01

    To investigate the effects of a prophylactic knee brace on knee joint kinetics and kinematics during netball specific movements. Repeated measures. Laboratory. Twenty university first team level female netball players. Participants performed three movements, run, cut and vertical jump under two conditions (brace and no-brace). 3-D knee joint kinetics and kinematics were measured using an eight-camera motion analysis system. Knee joint kinetics and kinematics were examined using 2 × 3 repeated measures ANOVA whilst the subjective ratings of comfort and stability were investigated using chi-squared tests. The results showed no differences (p > 0.05) in knee joint kinetics. However the internal/external rotation range of motion was significantly (p < 0.05) reduced when wearing the brace in all movements. The subjective ratings of stability revealed that netballers felt that the knee brace improved knee stability in all movements. Further study is required to determine whether reductions in transverse plane knee range of motion serve to attenuate the risk from injury in netballers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks.

    PubMed

    Bates, Nathaniel A; Nesbitt, Rebecca J; Shearn, Jason T; Myer, Gregory D; Hewett, Timothy E

    2016-07-01

    Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Descriptive laboratory study. A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, -7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. The mean (±SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60-0.65), flexion (r = 0.64-0.66), lateral (r = 0.57-0.69), and external rotation torques (r = 0.47-0.72) as well as inverse correlations with peak abduction (r = -0.42 to -0.61) and internal rotation torques (r = -0.39 to -0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64-0.69) and lateral knee force (r = 0.55-0.74) as well as inverse correlations with peak external torque (r = -0.34 to -0.67) and medial knee force (r = -0.58 to -0.59). These moderate correlations were also present during simulated sidestep cutting. The investigation supported the theory that increased posterior tibial slope would lead to greater magnitude knee joint moments, specifically

  17. The steps to forming a joint venture IPP in Poland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Z.; Colligan, M.J.

    Poland represents the largest market in Central Europe with 38 million people and an installed electrical generating capacity of about 32 gigawatts. Since 1989, when the process of governmental restructuring along free market principals began, the allure to IPP developers has been evident, but is of yet unrealized. The natural model for IPP development in Poland would seem to be joint ventures with Polish generating companies. These enterprises already have sites, franchises, and a going business to contribute to a joint company. There are a number of reasons why so few deals have been concluded in Poland to date, andmore » a number of barriers still exist that tend to hamper the realization of project finance funded power joint ventures. But, these barriers are not insurmountable. Overcoming them in the context of a joint venture relationship with a domestic partner requires patience, work, and an ability to bridge the gaps between the realities of working in a post-Communist environment and the practicalities of structuring projects that can be financed in the international capital markets. The new Energy Law in Poland establishes a framework for a viable private sector power generation business. But the enabling regulations are yet to be published or approved. There is still effective political risk on account of the uncertainty this creates. Pressure is mounting on the Polish Government, especially due to its expressed interest in joining the EU, to get the power sector to operate on private sector terms, if not in private hands. The trends are pointing in the direction of increased market driven policies and practices. The conclusion is that, despite the delays of the past, independent power projects will start to happen in Poland on a joint venture basis, with increasing frequency in the next years.« less

  18. In vivo kinematic study of the tarsal joints complex based on fluoroscopic 3D-2D registration technique.

    PubMed

    Chen Wang, M D; Geng, Xiang; Wang, Shaobai; Xin Ma, M D; Xu Wang, M D; Jiazhang Huang, M D; Chao Zhang, M D; Li Chen, M S; Yang, Junsheng; Wang, Kan

    2016-09-01

    The tarsal bones articulate with each other and demonstrate complicated kinematic characteristics. The in vivo motions of these tarsal joints during normal gait are still unclear. Seven healthy subjects were recruited and fourteen feet in total were tested in the current study. Three dimensional models of the tarsal bones were first created using CT scanning. Corresponding local 3D coordinate systems of each tarsal bone was subsequently established for 6DOF motion decompositions. The fluoroscopy system captured the lateral fluoroscopic images of the targeted tarsal region whilst the subject was walking. Seven key pose images during the stance phase were selected and 3D to 2D bone model registrations were performed on each image to determine joint positions. The 6DOF motions of each tarsal joint during gait were then obtained by connecting these positions together. The TNJ (talo-navicular joint) exhibited the largest ROMs (range of motion) on all rotational directions with 7.39±2.75°of dorsi/plantarflexion, 21.12±4.68°of inversion/eversion, and 16.11±4.44°of internal/external rotation. From heel strike to midstance, the TNJ, STJ (subtalar joint), and CCJ (calcaneao-cuboid joint) were associated with 5.97°, 5.04°, and 3.93°of dorsiflexion; 15.46°, 8.21°, and 5.82°of eversion; and 9.75°, 7.6°, and 4.99°of external rotation, respectively. Likewise, from midstance to heel off, the TNJ, STJ, and CCJ were associated with 6.39, 6.19°, and 4.47°of plantarflexion; 18.57°, 11.86°, and 6.32°of inversion and 13.95°, 9.66°, and 7.58°of internal rotation, respectively. In conclusion, among the tarsal joints, the TNJ exhibited the greatest rotational mobility. Synchronous and homodromous rotational motions were detected for TNJ, STJ, and CCJ during the stance phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Product evaluation : Ruscoe 983 joint sealant

    DOT National Transportation Integrated Search

    1986-07-10

    This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...

  20. Development of Displacement Gages Exposed to Solid Rocket Motor Internal Environments

    NASA Technical Reports Server (NTRS)

    Bolton, D. E.; Cook, D. J.

    2003-01-01

    The Space Shuttle Reusable Solid Rocket Motor (RSRM) has three non-vented segment-to-segment case field joints. These joints use an interference fit J-joint that is bonded at assembly with a Pressure Sensitive Adhesive (PSA) inboard of redundant O-ring seals. Full-scale motor and sub-scale test article experience has shown that the ability to preclude gas leakage past the J-joint is a function of PSA type, joint moisture from pre-assembly humidity exposure, and the magnitude of joint displacement during motor operation. To more accurately determine the axial displacements at the J-joints, two thermally durable displacement gages (one mechanical and one electrical) were designed and developed. The mechanical displacement gage concept was generated first as a non-electrical, self-contained gage to capture the maximum magnitude of the J-joint motion. When it became feasible, the electrical displacement gage concept was generated second as a real-time linear displacement gage. Both of these gages were refined in development testing that included hot internal solid rocket motor environments and simulated vibration environments. As a result of this gage development effort, joint motions have been measured in static fired RSRM J-joints where intentional venting was produced (Flight Support Motor #8, FSM-8) and nominal non-vented behavior occurred (FSM-9 and FSM-10). This data gives new insight into the nominal characteristics of the three case J-joint positions (forward, center and aft) and characteristics of some case J-joints that became vented during motor operation. The data supports previous structural model predictions. These gages will also be useful in evaluating J-joint motion differences in a five-segment Space Shuttle solid rocket motor.

  1. Gene-expression changes in knee-joint tissues with aging and menopause: implications for the joint as an organ

    PubMed Central

    Rollick, Natalie C; Lemmex, Devin B; Ono, Yohei; Reno, Carol R; Hart, David A; Lo, Ian KY; Thornton, Gail M

    2018-01-01

    Background When considering the “joint as an organ”, the tissues in a joint act as complementary components of an organ, and the “set point” is the cellular activity for homeostasis of the joint tissues. Even in the absence of injury, joint tissues have adaptive responses to processes, like aging and menopause, which result in changes to the set point. Purpose The purpose of this study in a preclinical model was to investigate age-related and menopause-related changes in knee-joint tissues with the hypothesis that tissues will change in unique ways that reflect their differing contributions to maintaining joint function (as measured by joint laxity) and the differing processes of aging and menopause. Methods Rabbit knee-joint tissues from three groups were evaluated: young adult (gene expression, n=8; joint laxity, n=7; water content, n=8), aging adult (gene expression, n=6; joint laxity, n=7; water content, n=5), and menopausal adult (gene expression, n=8; joint laxity, n=7; water content, n=8). Surgical menopause was induced with ovariohysterectomy surgery and gene expression was assessed using reverse-transcription quantitative polymerase chain reaction. Results Aging resulted in changes to 37 of the 150 gene–tissue combinations evaluated, and menopause resulted in changes to 39 of the 150. Despite the similar number of changes, only eleven changes were the same in both aging and menopause. No differences in joint laxity were detected comparing young adult rabbits with aging adult rabbits or with menopausal adult rabbits. Conclusion Aging and menopause affected the gene-expression patterns of the tissues of the knee joint differently, suggesting unique changes to the set point of the knee. Interestingly, aging and menopause did not affect knee-joint laxity, suggesting that joint function was maintained, despite changes in gene expression. Taken together, these findings support the theory of the joint as an organ where the tissues of the joint adapt to

  2. An Incidental Finding of a Talonavicular and Talocalcaneal Joint Coalition After a Tibial Pilon Fracture: A Case Report.

    PubMed

    Godoy, Heidi M; Micciche, Mark J

    It has been proposed that patients with talocalcaneal and talonavicular coalitions have decreased ankle joint range of motion. It has also been reported that rotational forces regularly absorbed by the talocalcaneal joint are transferred to the ankle joint in patients with coalitions, increasing the stress on the ankle joint after trauma. To the best of our knowledge, only 1 reported study has detailed the increased stress placed on the ankle joint secondary to a coalition. We present a case study of a 53-year-old female who experienced a traumatic fall and subsequent right ankle fracture. Advanced imaging studies revealed a comminuted tibial pilon fracture and talocalcaneal and talonavicular joint coalitions. She underwent open reduction and internal fixation for treatment of the fracture, and the coalitions were not treated because they were asymptomatic. She was kept non-weightbearing for 6 weeks postoperatively and was returned to a regular sneaker at 10 weeks postoperatively. The postoperative films revealed stable intact fixation and pain-free gait with no increased restriction in her ankle joint range of motion. The hardware was removed at 13 months postoperatively. She had not experienced increased pain or arthritic changes at 15 months postoperatively. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Anatomical frame identification and reconstruction for repeatable lower limb joint kinematics estimates.

    PubMed

    Donati, Marco; Camomilla, Valentina; Vannozzi, Giuseppe; Cappozzo, Aurelio

    2008-07-19

    The quantitative description of joint mechanics during movement requires the reconstruction of the position and orientation of selected anatomical axes with respect to a laboratory reference frame. These anatomical axes are identified through an ad hoc anatomical calibration procedure and their position and orientation are reconstructed relative to bone-embedded frames normally derived from photogrammetric marker positions and used to describe movement. The repeatability of anatomical calibration, both within and between subjects, is crucial for kinematic and kinetic end results. This paper illustrates an anatomical calibration approach, which does not require anatomical landmark manual palpation, described in the literature to be prone to great indeterminacy. This approach allows for the estimate of subject-specific bone morphology and automatic anatomical frame identification. The experimental procedure consists of digitization through photogrammetry of superficial points selected over the areas of the bone covered with a thin layer of soft tissue. Information concerning the location of internal anatomical landmarks, such as a joint center obtained using a functional approach, may also be added. The data thus acquired are matched with the digital model of a deformable template bone. Consequently, the repeatability of pelvis, knee and hip joint angles is determined. Five volunteers, each of whom performed five walking trials, and six operators, with no specific knowledge of anatomy, participated in the study. Descriptive statistics analysis was performed during upright posture, showing a limited dispersion of all angles (less than 3 deg) except for hip and knee internal-external rotation (6 deg and 9 deg, respectively). During level walking, the ratio of inter-operator and inter-trial error and an absolute subject-specific repeatability were assessed. For pelvic and hip angles, and knee flexion-extension the inter-operator error was equal to the inter-trial error

  4. Failure Analysis in Space: International Space Station (ISS) Starboard Solar Alpha Rotary Joint (SARJ) Debris Analysis

    NASA Technical Reports Server (NTRS)

    Long, V. S.; Wright, M. C.; McDanels, S. J.; Lubas, D.; Tucker, B.; Marciniak, P. J.

    2010-01-01

    This slide presentation reviews the debris analysis of the Starboard Solar Alpha Rotary Joint (SARJ), a mechanism that is designed to keep the solar arrays facing the sun. The goal of this was to identify the failure mechanism based on surface morphology and to determine the source of debris through elemental and particle analysis.

  5. International Trade Curriculum. A Joint Vocational Education Curriculum Project of Alaska, Oregon & Washington.

    ERIC Educational Resources Information Center

    Oregon State Dept. of Education, Salem. Div. of Vocational Technical Education.

    This document is intended to help instructors and administrators develop secondary and postsecondary instructional programs on international trade that are based on competencies identified as those needed in international business by companies in Alaska, Oregon, and Washington. The first section introduces competency-based curriculum and includes…

  6. Estimation of ligament strains and joint moments in the ankle during a supination sprain injury.

    PubMed

    Wei, Feng; Fong, Daniel Tik-Pui; Chan, Kai-Ming; Haut, Roger C

    2015-01-01

    This study presents the ankle ligament strains and ankle joint moments during an accidental injury event diagnosed as a grade I anterior talofibular ligament (ATaFL) sprain. A male athlete accidentally sprained his ankle while performing a cutting motion in a laboratory setting. The kinematic data were input to a three-dimensional rigid-body foot model for simulation analyses. Maximum strains in 20 ligaments were evaluated in simulations that investigated various combinations of the reported ankle joint motions. Temporal strains in the ATaFL and the calcaneofibular ligament (CaFL) were then compared and the three-dimensional ankle joint moments were evaluated from the model. The ATaFL and CaFL were highly strained when the inversion motion was simulated (10% for ATaFL and 12% for CaFL). These ligament strains were increased significantly when either or both plantarflexion and internal rotation motions were added in a temporal fashion (up to 20% for ATaFL and 16% for CaFL). Interestingly, at the time strain peaked in the ATaFL, the plantarflexion angle was not large but apparently important. This computational simulation study suggested that an inversion moment of approximately 23 N m plus an internal rotation moment of approximately 11 N m and a small plantarflexion moment may have generated a strain of 15-20% in the ATaFL to produce a grade I ligament injury in the athlete's ankle. This injury simulation study exhibited the potentially important roles of plantarflexion and internal rotation, when combined with a large inversion motion, to produce a grade I ATaFL injury in the ankle of this athlete.

  7. 76 FR 5231 - Joint Industry Plan; Notice of Filing and Immediate Effectiveness of Amendment No. 23 to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-28

    ... Organization Plan Governing the Collection, Consolidation and Dissemination of Quotation and Transaction...., EDGA Exchange, Inc., EDGX Exchange, Inc., Financial Industry Regulatory Authority, Inc., International... Joint Self-Regulatory Organization Plan Governing the Collection, Consolidation, and Dissemination of...

  8. Local effects and global impact in neurotoxicity and neurodegeneration: The Xi’an International Neurotoxicology Conference

    EPA Science Inventory

    “Neurotoxicity and Neurodegeneration: Local Effect and Global Impact” was the theme of the Xi’an International Neurotoxicology Conference (XINC), held in Xi’an, June 2011. The Conference was a joint event of the 13th Biennal Meeting of the International Neurotoxicology Associatio...

  9. Counterinsurgency and Operational Art: Is the Joint Campaign Planning Model Adequate?

    DTIC Science & Technology

    2003-01-01

    ART: IS THE JOINT CAMAPIGN PLANNING MODEL ADEQUATE? by MAJ Thomas Erik Miller, USA, 90 pages. The United States has conducted or supported more than a...increase. Some of the effects of the fall of the Soviet Union were a loosening of internal and external political and social controls in formerly Soviet...order” in the social , economic and political arena through rapid growth in population and urbanization in the underdeveloped world, globalization and

  10. Psychometric properties including reliability, validity and responsiveness of the Majeed pelvic score in patients with chronic sacroiliac joint pain.

    PubMed

    Bajada, Stefan; Mohanty, Khitish

    2016-06-01

    The Majeed scoring system is a disease-specific outcome measure that was originally designed to assess pelvic injuries. The aim of this study was to determine the psychometric properties of the Majeed scoring system for chronic sacroiliac joint pain. Internal consistency, content validity, criterion validity, construct validity and responsiveness to change was assessed prospectively for the Majeed scoring system in a cohort of 60 patients diagnosed with sacroiliac joint pain. This diagnosis was confirmed with CT-guided sacroiliac joint anaesthetic block. The overall Majeed score showed acceptable internal consistency (Cronbach alpha = 0.63). Similarly, it showed acceptable floor (0 %) and ceiling (0 %) effects. On the other hand, the domains of pain, work, sitting and sexual intercourse had high (>30 %) floor effects. Significant correlation with the physical component of the Short Form-36 (p = 0.005) and Oswestry disability index (p ≤ 0.001) was found indicating acceptable criterion validity. The overall Majeed score showed acceptable construct validity with all five developed hypotheses showing significance (p ≤ 0.05). The overall Majeed score showed acceptable responsiveness to change with a large (≥0.80) effect size and standardized response mean. Overall the Majeed scoring system demonstrated acceptable psychometric properties for outcome assessment in chronic sacroiliac joint pain. Thus, its use in this condition is adequate. However, some domains demonstrated suboptimal performance indicating that improvement might be achieved with the development of an outcome measure specific for sacroiliac joint dysfunction and degeneration.

  11. Biomechanical consequences of subtalar joint arthroereisis in treating posterior tibial tendon dysfunction: a theoretical analysis using finite element analysis.

    PubMed

    Wong, Duo Wai-Chi; Wang, Yan; Chen, Tony Lin-Wei; Leung, Aaron Kam-Lun; Zhang, Ming

    2017-11-01

    Subtalar joint arthroereisis (SJA) has been introduced to control the hyperpronation in cases of flatfoot. The objective of this study is to evaluate the biomechanical consequence of SJA to restore the internal stress and load transfer to the intact state from the attenuated biomechanical condition induced by posterior tibial tendon dysfunction (PTTD). A three-dimensional finite element model of the foot and ankle complex was constructed based on clinical images of a healthy female (age 28 years, height 165 cm, body mass 54 kg). The boundary and loading condition during walking was acquired from the gait experiment of the model subject. Five sets of simulations (conditions) were completed: intact condition, mild PTTD, severe PTTD, mild PTTD with SJA, severe PTTD with SJA. The maximum von Mises stress of the metatarsal shafts and the load transfer along the midfoot during stance were analyzed. Generally, SJA deteriorated the joint force of the medial cuneonavicular and calcaneocuboid joints during late stance, while that of the metatarsocuneiform joints during early stance were over-corrected. Only the calcaneocuboid joint force at 45% stance demonstrated a trend of improvement. Besides, SJA exaggerated the increased stress of the metatarsals compared to the PTTD conditions, except that of the first metatarsal. Our study did not support the hypothesis that SJA can restore the internal load transfer and midfoot stress. SJA cannot compensate the salvage of midfoot stability attributed by PTTD and could be biomechanically insufficient to restore the biomechanical environment. Additional procedures such as orthotic intervention may be necessary.

  12. Effects of step rate manipulation on joint mechanics during running.

    PubMed

    Heiderscheit, Bryan C; Chumanov, Elizabeth S; Michalski, Max P; Wille, Christa M; Ryan, Michael B

    2011-02-01

    the objective of this study was to characterize the biomechanical effects of step rate modification during running on the hip, knee, and ankle joints so as to evaluate a potential strategy to reduce lower extremity loading and risk for injury. three-dimensional kinematics and kinetics were recorded from 45 healthy recreational runners during treadmill running at constant speed under various step rate conditions (preferred, ± 5%, and ± 10%). We tested our primary hypothesis that a reduction in energy absorption by the lower extremity joints during the loading response would occur, primarily at the knee, when step rate was increased. less mechanical energy was absorbed at the knee (P < 0.01) during the +5% and +10% step rate conditions, whereas the hip (P < 0.01) absorbed less energy during the +10% condition only. All joints displayed substantially (P < 0.01) more energy absorption when preferred step rate was reduced by 10%. Step length (P < 0.01), center of mass vertical excursion (P < 0.01), braking impulse (P < 0.01), and peak knee flexion angle (P < 0.01) were observed to decrease with increasing step rate. When step rate was increased 10% above preferred, peak hip adduction angle (P < 0.01) and peak hip adduction (P < 0.01) and internal rotation (P < 0.01) moments were found to decrease. we conclude that subtle increases in step rate can substantially reduce the loading to the hip and knee joints during running and may prove beneficial in the prevention and treatment of common running-related injuries.

  13. Effects of Step Rate Manipulation on Joint Mechanics during Running

    PubMed Central

    Heiderscheit, Bryan C.; Chumanov, Elizabeth S.; Michalski, Max P.; Wille, Christa M.; Ryan, Michael B.

    2010-01-01

    Purpose The objective of this study was to characterize the biomechanical effects of step rate modification during running on the hip, knee and ankle joints, so as to evaluate a potential strategy to reduce lower extremity loading and risk for injury. Methods Three-dimensional kinematics and kinetics were recorded from 45 healthy recreational runners during treadmill running at constant speed under various step rate conditions (preferred, ± 5% and ± 10%). We tested our primary hypothesis that a reduction in energy absorption by the lower extremity joints during the loading response would occur, primarily at the knee, when step rate was increased. Results Less mechanical energy was absorbed at the knee (p<0.01) during the +5% and +10% step rate conditions, while the hip (p<0.01) absorbed less energy during the +10% condition only. All joints displayed substantially (p<0.01) more energy absorption when preferred step rate was reduced by 10. Step length (p<0.01), center of mass vertical excursion (p<0.01), breaking impulse (p<0.01) and peak knee flexion angle (p<0.01) were observed to decrease with increasing step rate. When step rate was increased 10% above preferred, peak hip adduction angle (p<0.01), as well as peak hip adduction (p<0.01) and internal rotation (p<0.01) moments, were found to decrease. Conclusion We conclude that subtle increases in step rate can substantially reduce the loading to the hip and knee joints during running and may prove beneficial in the prevention and treatment of common running-related injuries. PMID:20581720

  14. Knee joint distraction compared with total knee arthroplasty: a randomised controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; Emans, P J; Mastbergen, S C; Lafeber, F P J G

    2017-01-01

    Knee joint distraction (KJD) is a relatively new, knee-joint preserving procedure with the goal of delaying total knee arthroplasty (TKA) in young and middle-aged patients. We present a randomised controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes were assessed at baseline, three, six, nine, and 12 months. In the KJD group, the joint space width (JSW) was radiologically assessed, representing a surrogate marker of cartilage thickness. In total 56 patients completed their allocated treatment (TKA = 36, KJD = 20). All patient reported outcome measures improved significantly over one year (p < 0.02) in both groups. At one year, the TKA group showed a greater improvement in only one of the 16 patient-related outcome measures assessed (p = 0.034). Outcome Measures in Rheumatology-Osteoarthritis Research Society International clinical response was 83% after TKA and 80% after KJD. A total of 12 patients (60%) in the KJD group sustained pin track infections. In the KJD group both mean minimum (0.9 mm, standard deviation (sd) 1.1) and mean JSW (1.2 mm, sd 1.1) increased significantly (p = 0.004 and p = 0.0003). In relatively young patients with end-stage knee osteoarthritis, KJD did not demonstrate inferiority of outcomes at one year when compared with TKA. However, there is a high incidence of pin track infection associated with KJD. Cite this article: Bone Joint J 2017;99-B:51-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  15. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    PubMed Central

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  16. APEX-CAMBIUM: A Case Study in Advantages and Challenges of International Cooperation for the International Space Station

    NASA Technical Reports Server (NTRS)

    Cox, David; Buckley, Nicole

    2008-01-01

    It is generally agreed that space science benefits from an international collaboration. There are different mechanisms to make this happen but to recognize opportunities requires a keen awareness of the activities, people and respective strengths. Apex- Cambium is a joint Canadian Space Agency (CSA)-National Aeronautics and Space Administration (NASA) initiative. It was made possible in large part through the good relations and shared willingness to meet a common objective, that of doing exciting science in space. The actual mechanics of bringing an international project together can be divided into two perspectives: programmatic and implementation. The programmatic component includes recognizing complementarities, bringing science together, and the need to have Agencies approve and accept joint responsibility for the mission. The implementation component involves working to define science requirements, available resources and assigning individual responsibilities while keeping the overall success criteria as a collective objective. The APEX-CAMB11.JM mission will be described from the point of view of both CSA and NASA. Suggestions on how to facilitate these types of initiatives will be provided and highlights of the APEX-Cambium collaboration will be provided.

  17. Internal Maxillary Artery Preoperative Embolization Using n-Butyl Cyanoacrylate and Pushable Coils for Temporomandibular Joint Ankylosis Surgery.

    PubMed

    Alderazi, Yazan J; Shastri, Darshan; Wessel, John; Mathew, Melvin; Kass-Hout, Tareq; Aziz, Shahid R; Prestigiacomo, Charles J; Gandhi, Chirag D

    2017-05-01

    Temporomandibular joint (TMJ) ankylosis causes disability through impaired digestion, mastication, speech, and appearance. Surgical treatment increases range of motion with resultant functional improvement. However, substantial perioperative blood loss can occur (up to 3 L) if the internal maxillary artery (IMAX) is injured as it traverses the ankylotic mass. Achieving hemostasis is difficult because of limited proximal IMAX access and poor visualization. Our aim is to investigate the technical feasibility and preliminary safety of preoperative IMAX embolization in patients undergoing TMJ ankylosis surgery. Case series using chart reviews of 2 patients who underwent preoperative embolization before TMJ ankylosis surgery. Both patients were women (28 and 51 years old) who had severely restricted mouth opening. Embolization was performed using general anesthesia with nasal intubation on the same day of TMJ surgery. Both patients underwent bilateral IMAX embolization using pushable coils (Vortex, Boston Scientific) of distal IMAX followed by n-butyl-cyanoacrylate (Trufill, Cordis) embolization from coil mass up to proximal IMAX. There were no complications from the embolization procedures. Both patients had normal neurologic examination results. TMJ surgery occurred with minimal operative blood loss (≤300 mL for each surgery). Maximum postoperative mouth opening was 35 mm and 34 mm, respectively. One patient had a postoperative TMJ wound infection that was managed with antibiotics. Preoperative IMAX embolization before TMJ ankylosis surgery is technically feasible with encouraging preliminary safety. There were no complications from the embolization procedures and surgeries occurred with low volumes of blood loss. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Introduction to the special issue on the joint meeting of the 19th IEEE International Symposium on the Applications of Ferroelectrics and the 10th European Conference on the Applications of Polar Dielectrics.

    PubMed

    Tsurumi, Takaaki

    2011-09-01

    The joint meeting of the 19th IEEE International Symposium on the Applications of Ferroelectrics and the 10th European Conference on the Applications of Polar Dielectrics took place in Edinburgh from August 9-12, 2010. The conference was attended by 390 delegates from more than 40 different countries. There were 4 plenary speakers, 56 invited speakers, and a further 222 contributed oral presentations in 7 parallel session. In addition there were 215 poster presentations. Key topics addressed at the conference included piezoelectric materials, leadfree piezoelectrics, and multiferroics.

  19. Adjustable bias column end joint assembly

    NASA Technical Reports Server (NTRS)

    Wallsom, Richard E. (Inventor); Bush, Harold G. (Inventor)

    1994-01-01

    An adjustable mechanical end joint system for connecting structural column elements and eliminating the possibility of free movement between joint halves during loading or vibration has a node joint body having a cylindrical engaging end and a column end body having a cylindrical engaging end. The column end joint body has a compressible preload mechanism and plunger means housed therein. The compressible preload mechanism may be adjusted from the exterior of the column end joint body through a port.

  20. Arch structure is associated with unique joint work, relative joint contributions and stiffness during landing.

    PubMed

    Powell, Douglas W; Queen, Robin M; Williams, D S Blaise

    2016-10-01

    To examine lower extremity joint contributions to a landing task in high-(HA) and low-arched (LA) female athletes by quantifying vertical stiffness, joint work and relative joint contributions to landing. Twenty healthy female recreational athletes (10 HA and 10 LA) performed five barefoot drop landings from a height of 30cm. Three-dimensional kinematics (240Hz) and ground reaction forces (960Hz) were recorded simultaneously. Vertical stiffness, joint work values and relative joint work values were calculated using Visual 3D and MatLab. HA athletes had significantly greater vertical stiffness compared to LA athletes (p=0.013). Though no differences in ankle joint work were observed (p=0.252), HA athletes had smaller magnitudes of knee (p=0.046), hip (p=0.019) and total lower extremity joint work values (p=0.016) compared to LA athletes. HA athletes had greater relative contributions of the ankle (p=0.032) and smaller relative contributions of the hip (p=0.049) compared to LA athletes. No differences in relative contributions of the knee were observed (p=0.255). These findings demonstrate that aberrant foot structure is associated with unique contributions of lower extremity joints to load attenuation during landing. These data may provide insight into the unique injury mechanisms associated with arch height in female athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  2. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  3. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  4. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  5. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings, the...

  6. Quick-connect threaded attachment joint

    NASA Technical Reports Server (NTRS)

    Lucy, M. H.; Messick, W. R.; Vasquez, P.

    1979-01-01

    Joint is self-aligning and tightens with only sixty-five degrees of rotation for quick connects and disconnects. Made of injection-molded plastics or cast or machined aluminum, joint can carry wires, tubes, liquids, or gases. When two parts of joint are brought together, their shapes align them. Small projections on male section and slots on female section further aid alignment; slight rotation of male form engages projections in slots. At this point, threads engage and male section is rotated until joint is fully engaged.

  7. 78 FR 45187 - Notice of a Joint Technical Assistance Workshop for Preparing Fiscal Year (FY) 2014 Grant...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-26

    ... for programs authorized by Title VI of the Higher Education Act (HEA) that the Department expects to... DEPARTMENT OF EDUCATION Notice of a Joint Technical Assistance Workshop for Preparing Fiscal Year (FY) 2014 Grant Applications AGENCY: International and Foreign Language Education, Office of...

  8. Response of knee fibrocartilage to joint destabilization.

    PubMed

    Dyment, N A; Hagiwara, Y; Jiang, X; Huang, J; Adams, D J; Rowe, D W

    2015-06-01

    A major challenge to understanding osteoarthritis (OA) pathology is identifying the cellular events that precede the onset of cartilage damage. The objective of this study is to determine the effect of joint destabilization on early changes to fibrocartilage in the joint. The anterior cruciate ligament was transected in collagen reporter mice (Col1CFP and ColXRFP). Mineralization labels were given every 2 weeks to measure new mineralized cartilage apposition. Novel fluorescent histology of mineralized tissue was used to characterize the changes in fibrocartilage at 2 and 4 weeks post-injury. Changes in fibrocartilaginous structures of the joint occur as early as 2 weeks after injury and are well developed by 4 weeks. The alterations are seen in multiple entheses and in the medial surface of the femoral and tibial condyles. In the responding entheses, mineral apposition towards the ligament midsubstance results in thickening of the mineralize fibrocartilage. These changes are associated with increases in ColX-RFP, Col1-CFP reporter activity and alkaline phosphatase enzyme activity. Mineral apposition also occurs in the fibrocartilage of the non-articular regions of the medial condyles by 2 weeks and develops into osteophytes by 4 weeks post-injury. An unexpected observation is punctate expression of tartrate resistant acid phosphatase activity in unmineralized fibrochondrocytes adjacent to active appositional mineralization. These observations suggest that fibrocartilage activates prior to degradation of the articular cartilage. Thus clinical and histological imaging of fibrocartilage may be an earlier indicator of disease initiation and may indicate a more appropriate time to start preventative treatment. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  9. The contribution of quasi-joint stiffness of the ankle joint to gait in patients with hemiparesis.

    PubMed

    Sekiguchi, Yusuke; Muraki, Takayuki; Kuramatsu, Yuko; Furusawa, Yoshihito; Izumi, Shin-Ichi

    2012-06-01

    The role of ankle joint stiffness during gait in patients with hemiparesis has not been clarified. The purpose of this study was to determine the contribution of quasi-joint stiffness of the ankle joint to spatiotemporal and kinetic parameters regarding gait in patients with hemiparesis due to brain tumor or stroke and healthy individuals. Spatiotemporal and kinetic parameters regarding gait in twelve patients with hemiparesis due to brain tumor or stroke and nine healthy individuals were measured with a 3-dimensional motion analysis system. Quasi-joint stiffness was calculated from the slope of the linear regression of the moment-angle curve of the ankle joint during the second rocker. There was no significant difference in quasi-joint stiffness among both sides of patients and the right side of controls. Quasi-joint stiffness on the paretic side of patients with hemiparesis positively correlated with maximal ankle power (r=0.73, P<0.01) and gait speed (r=0.66, P<0.05). In contrast, quasi-joint stiffness in controls negatively correlated with maximal ankle power (r=-0.73, P<0.05) and gait speed (r=-0.76, P<0.05). Our findings suggested that ankle power during gait might be generated by increasing quasi-joint stiffness in patients with hemiparesis. In contrast, healthy individuals might decrease quasi-joint stiffness to avoid deceleration of forward tilt of the tibia. Our findings might be useful for selecting treatment for increased ankle stiffness due to contracture and spasticity in patients with hemiparesis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Broadband rotary joint for high speed ultrahigh resolution endoscopic OCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alemohammad, Milad; Yuan, Wu; Mavadia-Shukla, Jessica; Liang, Wenxuan; Yu, Xiaoyun; Yu, Shaoyong; Li, Xingde

    2016-03-01

    Endoscopic OCT is a promising technology enabling noninvasive in vivo imaging of internal organs, such as the gastrointestinal tract and airways. The past few years have witnessed continued efforts to achieve ultrahigh resolution and speed. It is well-known that the axial resolution in OCT imaging has a quadratic dependence on the central wavelength. While conventional OCT endoscopes operate in 1300 nm wavelength, the second-generation endoscopes are designed for operation around 800 nm where turn-key, broadband sources are becoming readily available. Traditionally 1300 nm OCT endoscopes are scanned at the proximal end, and a broadband fiber-optic rotary joint as a key component in scanning endoscopic OCT is commercially available. Bandwidths in commercial 800 nm rotary joints are unfortunately compromised due to severe chromatic aberration, which limits the resolution afforded by the broadband light source. In the past we remedied this limitation by using a home-made capillary-tube-based rotary joint where the maximum reliable speed is ~10 revolutions/second. In this submission we report our second-generation, home-built high-speed and broadband rotary joint for 800 nm wavelength, which uses achromatic doublets in order achieve broadband achromatic operation. The measured one-way throughput of the rotary joint is >67 % while the fluctuation of the double-pass coupling efficiency during 360° rotation is less than +/-5 % at a speed of 70 revolutions/second. We demonstrate the operation of this rotary joint in conjunction with our ultrahigh-resolution (2.4 µm in air) diffractive catheter by three-dimensional full-circumferential endoscopic imaging of guinea pig esophagus at 70 frames per second in vivo.

  11. Fatal hemorrhage following sacroiliac joint fusion surgery: A case report.

    PubMed

    Palmiere, Cristian; Augsburger, Marc; Del Mar Lesta, Maria; Grabherr, Silke; Borens, Olivier

    2017-05-01

    Threaded pins and wires are commonly used in orthopedic practice and their migration intra- or post-operatively may be responsible for potentially serious complications. Vascular and visceral injury from intra-pelvic pin or guide-wire migration during or following hip surgery has been reported frequently in the literature and may result in progression through soft tissues with subsequent perforation of organs and vessels. In this report, we describe an autopsy case involving a 40-year old man suffering from chronic low back pain due to sacroiliac joint disruption. The patient underwent minimally invasive sacroiliac joint arthrodesis. Some intra-operative bleeding was noticed when a drill was retrieved, though the patient died postoperatively. Postmortem investigations allowed the source of bleeding to be identified (a perforation of a branch of the right internal iliac artery) and a potentially toxic tramadol concentration in peripheral blood to be measured. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Double slotted socket spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2001-05-22

    A new class of spherical joints is disclosed. These spherical joints are capable of extremely large angular displacements (full cone angles in excess of 270.degree.), while exhibiting no singularities or dead spots in their range of motion. These joints can improve or simplify a wide range of mechanical devices.

  13. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation

    PubMed Central

    Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.

    2016-01-01

    Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763

  14. Clinical synovitis in a particular joint is associated with progression of erosions and joint space narrowing in that same joint, but not in patients initially treated with infliximab.

    PubMed

    Klarenbeek, N B; Güler-Yüksel, M; van der Heijde, D M F M; Hulsmans, H M J; Kerstens, P J S M; Molenaar, T H E; de Sonnaville, P B J; Huizinga, T W J; Dijkmans, B A C; Allaart, C F

    2010-12-01

    To assess the relationship between joint tenderness, swelling and joint damage progression in individual joints and to evaluate the influence of treatment on these relationships. First-year data of the Behandel Strategieën (BeSt) study were used, in which patients recently diagnosed as having rheumatoid arthritis (RA) were randomly assigned into four different treatment strategies. Baseline and 1-year x-rays of the hands and feet were assessed using the Sharp-van der Heijde score (SHS). With generalised estimating equations, 3-monthly assessments of tender and swollen joints of year 1 were related to erosion progression, joint space narrowing (JSN) progression and total SHS progression at the individual joint level (definition > 0.5 SHS units) in year 1, corrected for potential confounders and within-patient correlation for multiple joints per patient. During year 1, 59% of all 13 959 joints analysed were ever tender and 45% ever swollen, 2.1% showed erosion progression, 1.9% JSN progression and 3.6% SHS progression. Swelling and tenderness were both independently associated with erosion and JSN progression with comparable OR, although with higher OR in the hands than in the feet. Local swelling and tenderness were not associated with local damage progression in patients initially treated with infliximab. Clinical signs of synovitis are associated with erosion and JSN progression in individual joints after 1 year in RA. A disconnect between synovitis and joint damage progression was observed at joint level in patients who were treated with methotrexate and infliximab as initial treatment, confirming the disconnect between synovitis and the development of joint damage in tumour necrosis factor blockers seen at patient level.

  15. Hip joint replacement - slideshow

    MedlinePlus

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  16. Sacroiliac joint pain - aftercare

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000610.htm Sacroiliac joint pain - aftercare To use the sharing features on this page, please enable JavaScript. The sacroiliac joint (SIJ) is a term used to describe ...

  17. Metacarpophalangeal joint arthroscopy: indications revisited.

    PubMed

    Choi, Alexander K Y; Chow, Esther C S; Ho, P C; Chow, Y Y

    2011-08-01

    Arthroscopic surgery has become the gold standard for the diagnosis and treatment of major joint disorders. With advancement in arthroscopic technique, arthroscopy has become feasible in most human joints, even those as small as the finger joints. The metacarpophalangeal joint (MCPJ) can become spacious with simple traction, the intra-articular anatomy is simple, and its major structures can be easily visualized and identified. However, MCPJ arthroscopy has never been popular. This article describes our experience with MCPJ arthroscopy and seeks to establish its role in clinical practice. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Intra-articular nerve growth factor regulates development, but not maintenance, of injury-induced facet joint pain & spinal neuronal hypersensitivity.

    PubMed

    Kras, J V; Kartha, S; Winkelstein, B A

    2015-11-01

    The objective of the current study is to define whether intra-articular nerve growth factor (NGF), an inflammatory mediator that contributes to osteoarthritic pain, is necessary and sufficient for the development or maintenance of injury-induced facet joint pain and its concomitant spinal neuronal hyperexcitability. Male Holtzman rats underwent painful cervical facet joint distraction (FJD) or sham procedures. Mechanical hyperalgesia was assessed in the forepaws, and NGF expression was quantified in the C6/C7 facet joint. An anti-NGF antibody was administered intra-articularly in additional rats immediately or 1 day following facet distraction or sham procedures to block intra-articular NGF and test its contribution to initiation and/or maintenance of facet joint pain and spinal neuronal hyperexcitability. NGF was injected into the bilateral C6/C7 facet joints in separate rats to determine if NGF alone is sufficient to induce these behavioral and neuronal responses. NGF expression increases in the cervical facet joint in association with behavioral sensitivity after that joint's mechanical injury. Intra-articular application of anti-NGF immediately after a joint distraction prevents the development of both injury-induced pain and hyperexcitability of spinal neurons. Yet, intra-articular anti-NGF applied after pain has developed does not attenuate either behavioral or neuronal hyperexcitability. Intra-articular NGF administered to the facet in naïve rats also induces behavioral hypersensitivity and spinal neuronal hyperexcitability. Findings demonstrate that NGF in the facet joint contributes to the development of injury-induced joint pain. Localized blocking of NGF signaling in the joint may provide potential treatment for joint pain. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  19. Joint Attention in Autism: Teaching Smiling Coordinated with Gaze to Respond to Joint Attention Bids

    ERIC Educational Resources Information Center

    Krstovska-Guerrero, Ivana; Jones, Emily A.

    2013-01-01

    Children with autism demonstrate early deficits in joint attention and expressions of affect. Interventions to teach joint attention have addressed gaze behavior, gestures, and vocalizations, but have not specifically taught an expression of positive affect such as smiling that tends to occur during joint attention interactions. Intervention was…

  20. Sacroiliac joint tuberculosis: surgical management by posterior open-window focal debridement and joint fusion.

    PubMed

    Zhu, Guo; Jiang, Li-Yuan; Yi, Zhang; Ping, Li; Duan, Chun-Yue; Yong, Cao; Liu, Jin-Yang; Hu, Jian-Zhong

    2017-11-29

    Sacroiliac joint tuberculosis(SJT) is relatively uncommon, but it may cause severe sacroiliac joint destruction and functional disorder. Few studies in the literature have been presented on SJT, reports of surgical treatment for SJT are even fewer. In this study, we retrospectively reviewed surgical management of patients with severe SJT of 3 different types and proposed to reveal the clinical manifestations and features and aim to determine the efficiency and security of such surgical treatment. We reviewed 17 patients with severe SJT of 3 different types who underwent posterior open-window focal debridement and bone graft for joint fusion. Among them,five patients with anterior sacral abscess had anterior abscess curettage before debridement. Two patients with lumbar vertebral tuberculosis received one-stage posterior tuberculous debridement, interbody fusion and instrumentation. Follow-up was performed 36 months (26 to 45 months) using the following parameters: erythrocyte sedimentation rate(ESR), status of joint bony fusion on CT scan, visual analogue scale (VAS) and the Oswestry Disability Index (ODI). Buttock pain and low back pain were progressively relieved with time. 6 months later, pain was not obvious, and ESR resumed to normal levels within 3 months. Solid fusion of the sacroiliac joint occurred within 12 months in all cases. No complications or recurrence occurred. At final follow-up, all patients had no pain or only minimal discomfort over the affected joint and almost complete functional recovery. Posterior open-window focal debridement and joint fusion is an efficient and secure surgical method to treat severe SJT. If there is an abscess in the front of the sacroiliac joint, anterior abscess curettage should be performed as a supplement.

  1. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    PubMed

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  2. Jointness for the Rest of Us: Reforming Joint Professional Development

    DTIC Science & Technology

    2016-06-10

    where service capabilities are combined to maximize effectiveness while minimizing vulnerabilities. However, despite the passage of thirty years ...staff of the Joint Advance Warfighting School and the Joint Forces Staff College for their support during the academic year . Special thanks to my...seminar faculty Colonel Chris Rogers, Dr. Mike Pavlec, and Captain Miguel “Boo” Peko for the lessons and laughs that have made this year so enjoyable

  3. PREFACE: 2013 Joint IMEKO (International Measurement Confederation) TC1-TC7-TC13 Symposium: Measurement Across Physical and Behavioural Sciences

    NASA Astrophysics Data System (ADS)

    Battista Rossi, Giovanni; Crenna, Francesco; Belotti, Vittorio

    2013-09-01

    The 2013 Joint IMEKO (International Measurement Confederation) TC1-C7-TC13 was organised by the University of Genova - DIME/MEC, Measurement Laboratory, Italy, on 4-6 September 2013. The work of this symposium is reported in this volume. The scope of the symposium includes the main topics covered by the above Technical Committees: TC1 Education and Training in Measurement and Instrumentation TC7 Measurement Science TC13 Measurements in Biology and Medicine This is in keeping with the tradition set by the previous events of this well established series. There has been a special focus on measurement across physical and behavioural sciences, with the aim of highlighting the interdisciplinary character of measurement science and of promoting constructive interactions with scientists in other disciplines. The discussion was introduced by keynote lectures on measurement challenges in psychophysics, psychometrics and quantum physics. The symposium was attended by experts working in these areas from 18 countries, including USA, Australia and Japan, and provided a useful forum for them to share and exchange their work and ideas. In total over sixty papers are included in the volume, organised according to the presentation sessions. Each paper was independently peer-reviewed by two reviewers from a distinguished international panel. The Symposium was held in Genova, which was the European Capital of Culture in 2004, and took place in Palazzo Ducale, an important historical building whose construction started in the 13th century, and that has been the house of the Duke of Genova from the 14th century. Genova, whose name comes from the Latin word 'Janua' (meaning 'door', as January is the door month of the year), has been regarded over the centuries as a door connecting Europe with the different countries and cultures of the Mediterranean basin and thus was an appropriate site for an international symposium involving different and new scientific visions and approaches to

  4. TOPEX/POSEIDON joint verification plan

    NASA Technical Reports Server (NTRS)

    1992-01-01

    TOPEX/POSEIDON is a satellite mission that will use altimetry to make precise measurements of sea level with the primary goal of studying global ocean circulation. The mission is jointly conducted by the United States' National Aeronautics and Space Administration (NASA) and the French space agency, Centre National d'Etudes Spatiales (CNES). The current plans call for a launch of the satellite in August 1992. The primary mission will last 3 years, and provisions were made to extend the mission for an additional 2 years. The mission was coordinated with a number of international oceanographic and meteorological programs, including the World Ocean Circulation Experiment and the Tropical Ocean and Global Atmosphere Program, both of which are sponsored by the World Climate Research Program. The observations of TOPEX/POSEIDON are timed to provide a global perspective for interpreting the in situ measurements collected by these programs and in turn will be combined with observations of other satellites to achieve a global, four-dimensional description of the circulation of the world's oceans. In the autumn of 1987, an international team of 38 Principal Investigators was selected to participate in the mission. These scientists have been working closely with the TOPEX/POSEIDON Project to refine the mission design and science plans. During the first 6 months after launch, a number of these investigators will join with the project to conduct a wide range of oceanographic and geophysical investigations using the TOPEX/POSEIDON data. The purpose of these investigations is to demonstrate the scientific utility of the mission to the international scientific community.

  5. About the Joint Chiefs of Staff

    Science.gov Websites

    JCS: Search Home Media News Photos Videos Publications About The Joint Staff Chairman Vice Chairman J8 | Force Structure, Resources & Assessment Contact Joint Staff Structure Home : About About the Joint Chiefs of Staff Download the CJCS Historic Guide The Joint Chiefs of Staff consist of the Chairman

  6. Surface Observation Climatic Summaries (SOCS) for Fresno Air Terminal, California

    DTIC Science & Technology

    1989-09-01

    119 42 331 337 124 2 Same IUSO ISep 61 Jun 66 N 36 46 U 119 43 Same 330 24 3 Same IUSO IJun 66 Dec 85 Same Same 332 Same 24 4 Same uSO IJan 86 Jan 89...MONTH JAN I FEB IMAR I APR I MAY I JUN IJUL I AUG ISEP I OCT I NOV I DEC I ANN I YOR I MEAN MAX...VISIBILITY MONTH IJAN I FEB IMAR IAPR IMAY JUN IJUL IAUG ISEP jOCT INOV IDEC ANN IYOR 1 . o. ee. . lST I . I................I......... I...... I Io

  7. First and Second Order Stokes Generation by SRS in Methane: Influence of Rep-Rate, Beam Quality and Astigmatism (Opwekking van Eerste en Tweede Orde Stokes d.m.v. SRS in Methaan: Invloed van de Pulsfrequentie, de Bundelkwaliteit en Astigmatisme)

    DTIC Science & Technology

    1992-09-01

    omzettings rendementen van circa 75% gehaad bij een ingangs- energie van 280 mJ. De mogelijkheden tot bet halen van een hoger rendement lijken...of rep-rate, beam quality and astigmatism DImi-Thu-B~mO ITA1EiM-tT-h lF I~~ ~~’ IAPR2 8 1993~ I ~Xtbai Uiitdw FJ.M. van Putten J.C. van den Heuvel RJ.L...Influence of rep-rate. beam quality and astigmatism author(s) : F.J.M. van Putten, I.C. van den Heuvel, R.J.L. Lerou institute : TNO Physics and

  8. International Cooperation in Acquisition, Technology and Logistics (IC in AT&L) Handbook

    DTIC Science & Technology

    2012-05-01

    Information exchanges, for instance, may lead to a cooperative RD&A project . Figure 1-1 illustrates this “ building block” concept of international...support the National Security Strategy, including the need to strengthen alliances and build partnerships. CWP projects are selected for their... projects : prime contractor (with international teaming of subcontractors), consortium and joint venture. The selection of the best industrial

  9. Large displacement spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2002-01-01

    A new class of spherical joints has a very large accessible full cone angle, a property which is beneficial for a wide range of applications. Despite the large cone angles, these joints move freely without singularities.

  10. Joint inversion of apparent resistivity and seismic surface and body wave data

    NASA Astrophysics Data System (ADS)

    Garofalo, Flora; Sauvin, Guillaume; Valentina Socco, Laura; Lecomte, Isabelle

    2013-04-01

    A novel inversion algorithm has been implemented to jointly invert apparent resistivity curves from vertical electric soundings, surface wave dispersion curves, and P-wave travel times. The algorithm works in the case of laterally varying layered sites. Surface wave dispersion curves and P-wave travel times can be extracted from the same seismic dataset and apparent resistivity curves can be obtained from continuous vertical electric sounding acquisition. The inversion scheme is based on a series of local 1D layered models whose unknown parameters are thickness h, S-wave velocity Vs, P-wave velocity Vp, and Resistivity R of each layer. 1D models are linked to surface-wave dispersion curves and apparent resistivity curves through classical 1D forward modelling, while a 2D model is created by interpolating the 1D models and is linked to refracted P-wave hodograms. A priori information can be included in the inversion and a spatial regularization is introduced as a set of constraints between model parameters of adjacent models and layers. Both a priori information and regularization are weighted by covariance matrixes. We show the comparison of individual inversions and joint inversion for a synthetic dataset that presents smooth lateral variations. Performing individual inversions, the poor sensitivity to some model parameters leads to estimation errors up to 62.5 %, whereas for joint inversion the cooperation of different techniques reduces most of the model estimation errors below 5% with few exceptions up to 39 %, with an overall improvement. Even though the final model retrieved by joint inversion is internally consistent and more reliable, the analysis of the results evidences unacceptable values of Vp/Vs ratio for some layers, thus providing negative Poisson's ratio values. To further improve the inversion performances, an additional constraint is added imposing Poisson's ratio in the range 0-0.5. The final results are globally improved by the introduction of

  11. Does Success Of Arthroscopic Laser Surgery In The Knee Joint Warrant Its Extension To "Non-Knee" Joints?

    NASA Astrophysics Data System (ADS)

    Smith, Chadwick F.; Johansen, W. Edward; Vangness, C. Thomas; Yamaguchi, Ken; McEleney, Emmett T.; Bales, Peter

    1987-03-01

    One of the authors has performed 162 arthroscopic laser surgeries in the knee joint without any major complication. Other investigators have recently proposed diagnostic arthroscopy and arthroscopic surgery for "non-knee" joints. The authors have proposed that arthroscopic laser surgery he extended to "non-knee" joints. The authors have performed arthroscopic laser surgery on "non-knee" joints of twelve cadavers. One of the authors have performed one successful arthroscopic surgery on a shoulder joint with only a minor, transient complication of subcutaneous emphysema. Is laser arthroscopic surgery safe and effective in "non-knee" joints? The evolving answer appears to be a qualified "Yes," which needs to be verified by a multicenter trial.

  12. Estimation of Time-Varying, Intrinsic and Reflex Dynamic Joint Stiffness during Movement. Application to the Ankle Joint

    PubMed Central

    Guarín, Diego L.; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness determines the relation between joint position and torque, and plays a vital role in the control of posture and movement. Dynamic joint stiffness can be quantified during quasi-stationary conditions using disturbance experiments, where small position perturbations are applied to the joint and the torque response is recorded. Dynamic joint stiffness is composed of intrinsic and reflex mechanisms that act and change together, so that nonlinear, mathematical models and specialized system identification techniques are necessary to estimate their relative contributions to overall joint stiffness. Quasi-stationary experiments have demonstrated that dynamic joint stiffness is heavily modulated by joint position and voluntary torque. Consequently, during movement, when joint position and torque change rapidly, dynamic joint stiffness will be Time-Varying (TV). This paper introduces a new method to quantify the TV intrinsic and reflex components of dynamic joint stiffness during movement. The algorithm combines ensemble and deterministic approaches for estimation of TV systems; and uses a TV, parallel-cascade, nonlinear system identification technique to separate overall dynamic joint stiffness into intrinsic and reflex components from position and torque records. Simulation studies of a stiffness model, whose parameters varied with time as is expected during walking, demonstrated that the new algorithm accurately tracked the changes in dynamic joint stiffness using as little as 40 gait cycles. The method was also used to estimate the intrinsic and reflex dynamic ankle stiffness from an experiment with a healthy subject during which ankle movements were imposed while the subject maintained a constant muscle contraction. The method identified TV stiffness model parameters that predicted the measured torque very well, accounting for more than 95% of its variance. Moreover, both intrinsic and reflex dynamic stiffness were heavily modulated through the

  13. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  14. Swivel Joint For Liquid Nitrogen

    NASA Technical Reports Server (NTRS)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  15. The Standard Joint Unit.

    PubMed

    Casajuana Kögel, Cristina; Balcells-Olivero, María Mercedes; López-Pelayo, Hugo; Miquel, Laia; Teixidó, Lídia; Colom, Joan; Nutt, David John; Rehm, Jürgen; Gual, Antoni

    2017-07-01

    Reliable data on cannabis quantities is required to improve assessment of cannabis consumption for epidemiological analysis and clinical assessment, consequently a Standard Joint Unit (SJU) based on quantity of 9-Tetrahydrocannabinol (9-THC) has been established. Naturalistic study of a convenience sample recruited from February 2015-June 2016 in universities, leisure spaces, mental health services and cannabis clubs in Barcelona. Adults, reporting cannabis use in the last 60 days, without cognitive impairment or language barriers, answered a questionnaire on cannabis use and were asked to donate a joint to further determine their 9-THC and Cannabidiol (CBD) content. 492 participants donated 315 valid joints. Donators were on average 29 years old, mostly men (77%), single (75%), with at least secondary studies (73%) and in active employment (63%). Marijuana joints (N=232) contained a median of 6.56mg of 9-THC (Interquartile range-IQR=10,22) and 0.02mg of CBD (IQR=0.02); hashish joints (N=83) a median of 7.94mg of 9-THC (IQR=10,61) and 3.24mg of CBD (IQR=3.21). Participants rolled 4 joints per gram of cannabis and paid 5€ per gram (median values). Consistent 9-THC-content in joints lead to a SJU of 7mg of 9-THC, the integer number closest to the median values shared by both cannabis types. Independently if marijuana or hashish, 1 SJU = 1 joint = 0.25 g of cannabis = 7 mg of 9-THC. For CBD, only hashish SJU contained relevant levels. Similarly to the Standard Drink Unit for alcohol, the SJU is useful for clinical, epidemiological and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    PubMed

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  17. Torso and Bowing Arm Three-Dimensional Joint Kinematics of Elite Cellists: Clinical and Pedagogical Implications for Practice.

    PubMed

    Hopper, Luke; Chan, Cliffton; Wijsman, Suzanne; Ackland, Timothy; Visentin, Peter; Alderson, Jacqueline

    2017-06-01

    Elite cello playing requires complex and refined motor control. Cellists are prone to right shoulder and thoracolumbar injuries. Research informing injury management of cellists and cello pedagogy is limited. The aims of this study were to quantify the torso, right shoulder, and elbow joint movement used by elite cellists while performing a fundamental playing task, a C major scale, under two volume conditions. An eight degrees of freedom upper limb biomechanical model was applied to 3D motion capture data of the torso, upper arm, and forearm for 31 cellists with a mean experience of 19.4 yrs (SD 9.1). Two-factor ANOVA compared the joint positions between the four cello strings and two volume conditions. Significant (p<0.05) effects were found for either the string and/or volume conditions across all torso, shoulder, and elbow joint degrees of freedom. The torso was consistently positioned in left rotation from 5.0° (SD 5.6) at the beginning of the scale, increasing to 16.3° (5.5) at its apogee. The greatest mean shoulder flexion, internal rotation, and abduction joint angles were observed when playing at the tip of the bow on the top string (A): 107.2° (11.6), 59.1° (7.1), and -76.9° (15.7), respectively, during loud playing. Elite cellists use specific movement patterns to achieve string crossings and volume regulation during fundamental playing tasks. Implications of the static left-rotated torso posture and high degrees of combined shoulder flexion and internal rotation can be used to inform clinical and pedagogical practices.

  18. Temporo mandibular joint ankylosis.

    PubMed

    Vasconcelos, Belmiro Cavalcanti do Egito; Porto, Gabriela Granja; Bessa-Nogueira, Ricardo Viana

    2008-01-01

    Ankylosis may be defined as joint surfaces fusion. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high recurrence rate. The aim of this study is to report six cases treated by joint reconstruction, evaluate the results of these surgeries and review the literature. The sample in this retrospective study was obtained from the records of the university hospital, patients who had to undergo ankylosis treatment by alloplastic or autogenous graft between March 2001 and October 2005. Pre - and post-operative assessment included a throughout history and physical examination to determine the cause of ankylosis, the Maximum mouth opening (MMO), etiology and type of ankylosis, recurrence rate and presence of facial nerve paralysis. The mean MMO in the pre-operative period was 9.6 mm (0 mm to 17 mm) and in the post-operative period it was of 31.33 mm (14 mm to 41 mm), there was no facial nerve paralysis and there was recurrence in just one case. The joint reconstruction with alloplastic or autogenous grafts for the ankylosis treatment proved to be efficient in relation to the post-operative MMO, recurrence and joint function.

  19. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system.

    PubMed

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry(®) SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed.

  20. Unloading joints to treat osteoarthritis, including joint distraction.

    PubMed

    Lafeber, Floris P J G; Intema, Femke; Van Roermund, Peter M; Marijnissen, Anne C A

    2006-09-01

    Patients are increasingly becoming interested in nonpharmacologic approaches to manage their osteoarthritis. This review examines the recent literature on the potential beneficial effects of unloading joints in the treatment of osteoarthritis, with a focus on joint distraction. Mechanical factors are involved in the development and progression of osteoarthritis. If "loading" is a major cause in development and progression of osteoarthritis, then "unloading" may be able to prevent progression. There is evidence that unloading may be effective in reducing pain and slowing down structural damage. This review describes unloading by footwear and bracing (nonsurgical), unloading by osteotomy (surgical), and has a focus on unloading by joint distraction. Excellent reviews in all these three fields have been published over the past few years. Recent studies argue for the usefulness of a biomechanical approach to improve function and possibly reduce disease progression in osteoarthritis. To improve patient function and possibly reduce disease progression, a biomechanical approach should be considered in treating patients with osteoarthritis. Further research (appropriate high-quality clinical trials) and analysis (clinical as well as preclinical and fundamental) are still necessary, however, to understand, validate, and refine the different approaches of unloading to treat osteoarthritis.

  1. Joint design of QC-LDPC codes for coded cooperation system with joint iterative decoding

    NASA Astrophysics Data System (ADS)

    Zhang, Shunwai; Yang, Fengfan; Tang, Lei; Ejaz, Saqib; Luo, Lin; Maharaj, B. T.

    2016-03-01

    In this paper, we investigate joint design of quasi-cyclic low-density-parity-check (QC-LDPC) codes for coded cooperation system with joint iterative decoding in the destination. First, QC-LDPC codes based on the base matrix and exponent matrix are introduced, and then we describe two types of girth-4 cycles in QC-LDPC codes employed by the source and relay. In the equivalent parity-check matrix corresponding to the jointly designed QC-LDPC codes employed by the source and relay, all girth-4 cycles including both type I and type II are cancelled. Theoretical analysis and numerical simulations show that the jointly designed QC-LDPC coded cooperation well combines cooperation gain and channel coding gain, and outperforms the coded non-cooperation under the same conditions. Furthermore, the bit error rate performance of the coded cooperation employing jointly designed QC-LDPC codes is better than those of random LDPC codes and separately designed QC-LDPC codes over AWGN channels.

  2. The joint venture alternative to mergers.

    PubMed

    Enders, R J

    1995-02-01

    However, while a joint venture may be "safe" from antitrust challenge, it is not without some practical difficulties, especially with respect to consolidating services at one location or jointly offering services provided at multiple facilities. These practical concerns include: 1. Who will exercise operational management of the joint venture? 2. How will the joint venture deal with different pricing for services that will be provided at multiple locations? 3. What criteria will be used to decide the location at which consolidated tertiary services will be offered? 4. In what circumstances can the joint venture be unwound, either in its entirety or as to discrete functions? When clinical services have been consolidated at one location, there is an appropriate concern by the other hospital that it will be unable to provide or re-enter the market for those services if the joint venture dissolves. These operational concerns, of course, are not addressed in the Consent Decree. Thus, even if a joint venture relationship survives antitrust scrutiny, the parties must still negotiate and resolve these operational issues in order for the joint venture to be viable.

  3. Innervation of the Anterior Sacroiliac Joint.

    PubMed

    Cox, Marcus; Ng, Garrett; Mashriqi, Faizullah; Iwanaga, Joe; Alonso, Fernando; Tubbs, Kevin; Loukas, Marios; Oskouian, Rod J; Tubbs, R Shane

    2017-11-01

    Sacroiliac joint pain can be disabling and recalcitrant to medical therapy. The innervation of this joint is poorly understood, especially its anterior aspect. Therefore, the present cadaveric study was performed to better elucidate this anatomy. Twenty-four cadaveric sides underwent dissection of the anterior sacroiliac joint, with special attention given to any branches from regional nerves to this joint. No femoral, obturator, or lumbosacral trunk branches destined to the anterior sacroiliac joint were identified in the 24 sides. In 20 sides, one or two small branches (less than 0.5 mm in diameter) were found to arise from the L4 ventral ramus (10%), the L5 ventral ramus (80%), or simultaneously from both the L4 and L5 ventral rami (10%). The length of the branches ranged from 5 to 31 mm (mean, 14 mm). All these branches arose from the posterior part of the nerves and traveled to the anterior surface of the sacroiliac joint. No statistical significance was found between sides or sexes. An improved knowledge of the innervation of the anterior sacroiliac joint might decrease suffering in patients with chronic sacroiliac joint pain. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Bolted joints in graphite-epoxy composites

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1976-01-01

    All-graphite/epoxy laminates and hybrid graphite-glass/epoxy laminates were tested. The tests encompassed a range of geometries for each laminate pattern to cover the three basic failure modes - net section tension failure through the bolt hole, bearing and shearout. Static tensile and compressive loads were applied. A constant bolt diameter of 6.35 mm (0.25 in.) was used in the tests. The interaction of stress concentrations associated with multi-row bolted joints was investigated by testing single- and double-row bolted joints and open-hole specimens in tension. For tension loading, linear interaction was found to exist between the bearing stress reacted at a given bolt hole and the remaining tension stress running by that hole to be reacted elsewhere. The interaction under compressive loading was found to be non-linear. Comparative tests were run using single-lap bolted joints and double-lap joints with pin connection. Both of these joint types exhibited lower strengths than were demonstrated by the corresponding double-lap joints. The analysis methods developed here for single bolt joints are shown to be capable of predicting the behavior of multi-row joints.

  5. Space Station alpha joint bearing

    NASA Technical Reports Server (NTRS)

    Everman, Michael R.; Jones, P. Alan; Spencer, Porter A.

    1987-01-01

    Perhaps the most critical structural system aboard the Space Station is the Solar Alpha Rotary Joint which helps align the power generation system with the sun. The joint must provide structural support and controlled rotation to the outboard transverse booms as well as power and data transfer across the joint. The Solar Alpha Rotary Joint is composed of two transition sections and an integral, large diameter bearing. Alpha joint bearing design presents a particularly interesting problem because of its large size and need for high reliability, stiffness, and on orbit maintability. The discrete roller bearing developed is a novel refinement to cam follower technology. It offers thermal compensation and ease of on-orbit maintenance that are not found in conventional rolling element bearings. How the bearing design evolved is summarized. Driving requirements are reviewed, alternative concepts assessed, and the selected design is described.

  6. A Lossless Multichannel Bio-Signal Compression Based on Low-Complexity Joint Coding Scheme for Portable Medical Devices

    PubMed Central

    Kim, Dong-Sun; Kwon, Jin-San

    2014-01-01

    Research on real-time health systems have received great attention during recent years and the needs of high-quality personal multichannel medical signal compression for personal medical product applications are increasing. The international MPEG-4 audio lossless coding (ALS) standard supports a joint channel-coding scheme for improving compression performance of multichannel signals and it is very efficient compression method for multi-channel biosignals. However, the computational complexity of such a multichannel coding scheme is significantly greater than that of other lossless audio encoders. In this paper, we present a multichannel hardware encoder based on a low-complexity joint-coding technique and shared multiplier scheme for portable devices. A joint-coding decision method and a reference channel selection scheme are modified for a low-complexity joint coder. The proposed joint coding decision method determines the optimized joint-coding operation based on the relationship between the cross correlation of residual signals and the compression ratio. The reference channel selection is designed to select a channel for the entropy coding of the joint coding. The hardware encoder operates at a 40 MHz clock frequency and supports two-channel parallel encoding for the multichannel monitoring system. Experimental results show that the compression ratio increases by 0.06%, whereas the computational complexity decreases by 20.72% compared to the MPEG-4 ALS reference software encoder. In addition, the compression ratio increases by about 11.92%, compared to the single channel based bio-signal lossless data compressor. PMID:25237900

  7. Correlations between Angular Velocities in Selected Joints and Velocity of Table Tennis Racket during Topspin Forehand and Backhand

    PubMed Central

    Bańkosz, Ziemowit; Winiarski, Sławomir

    2018-01-01

    The aim of this study was to determine the correlations between angular velocities in individual joints and racket velocity for different topspin forehand and backhand strokes in table tennis. Ten elite female table tennis players participated, presenting different kinds of topspin forehands and backhands – after a no-spin ball (FH1, BH1), after a backspin ball (FH2, BH2) and “heavy” topspin (FH3, BH3). Range of motion was measured with the BTS Smart-E (BTS Bioengineering, Milan, Italy) motion analysis system with a specially developed marker placement protocol for the upper body parts and an acoustic sensor attached to the racket to identify ball-racket contact. In forehand strokes angular velocities of internal arm rotation and adduction in shoulder joint correlated with racket velocity. Racket velocity was correlated with angular velocities (hip extension on the playing side; hip flexion on the opposite side; ankle flexion) in the case of a topspin forehand performed with maximal force –”heavy” topspin (FH3). In backhand strokes the velocities of arm abduction and shoulder girdle rotation towards the playing side correlated with racket velocity. The angular velocity of internal arm rotation and adduction in shoulder joint may be important components of a coordinated stroke, whilst angular velocity can substantially affect the racket speed when one is changing the type of stroke. Key points The aim of this study was to calculate correlations between racket velocity and the angular velocities of individual joints and for variants of topspin forehand and backhand strokes in table tennis. A novel model was used to estimate range of motion (specially developed placement protocol for upper body markers and identification of a ball-racket contact using an acoustic sensor attached to the racket). In forehand strokes angular velocities of internal arm rotation and adduction in shoulder joint were correlated with racket velocity. Correlations between racket

  8. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    PubMed

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  9. Joint distraction attenuates osteoarthritis by reducing secondary inflammation, cartilage degeneration and subchondral bone aberrant change.

    PubMed

    Chen, Y; Sun, Y; Pan, X; Ho, K; Li, G

    2015-10-01

    Osteoarthritis (OA) is a progressive joint disorder. To date, there is not effective medical therapy. Joint distraction has given us hope for slowing down the OA progression. In this study, we investigated the benefits of joint distraction in OA rat model and the probable underlying mechanisms. OA was induced in the right knee joint of rats through anterior cruciate ligament transaction (ACLT) plus medial meniscus resection. The animals were randomized into three groups: two groups were treated with an external fixator for a subsequent 3 weeks, one with and one without joint distraction; and one group without external fixator as OA control. Serum interleukin-1β level was evaluated by ELISA; cartilage quality was assessed by histology examinations (gross appearance, Safranin-O/Fast green stain) and immunohistochemistry examinations (MMP13, Col X); subchondral bone aberrant changes was analyzed by micro-CT and immunohistochemistry (Nestin, Osterix) examinations. Characters of OA were present in the OA group, contrary to in general less severe damage after distraction treatment: firstly, IL-1β level was significantly decreased; secondly, cartilage degeneration was attenuated with lower histologic damage scores and the lower percentage of MMP13 or Col X positive chondrocytes; finally, subchondral bone abnormal change was attenuated, with reduced bone mineral density (BMD) and bone volume/total tissue volume (BV/TV) and the number of Nestin or Osterix positive cells in the subchondral bone. In the present study, we demonstrated that joint distraction reduced the level of secondary inflammation, cartilage degeneration and subchondral bone aberrant change, joint distraction may be a strategy for slowing OA progression. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  10. Biomechanics of an orthosis-managed cranial cruciate ligament-deficient canine stifle joint predicted by use of a computer model.

    PubMed

    Bertocci, Gina E; Brown, Nathan P; Mich, Patrice M

    2017-01-01

    OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.

  11. Self-Alining Quick-Connect Joint

    NASA Technical Reports Server (NTRS)

    Lucy, M. H.

    1983-01-01

    Quick connect tapered joint used with minimum manipulation and force. Split ring retainer holds locking ring in place. Minimal force required to position male in female joint, at which time split-ring retainers are triggered to release split locking rings. Originally developed to assemble large space structures, joint is simple, compact, strong, lightweight, self alining, and has no loose parts.

  12. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  13. Human arm stiffness and equilibrium-point trajectory during multi-joint movement.

    PubMed

    Gomi, H; Kawato, M

    1997-03-01

    By using a newly designed high-performance manipulandum and a new estimation algorithm, we measured human multi-joint arm stiffness parameters during multi-joint point-to-point movements on a horizontal plane. This manipulandum allows us to apply a sufficient perturbation to subject's arm within a brief period during movement. Arm stiffness parameters were reliably estimated using a new algorithm, in which all unknown structural parameters could be estimated independent of arm posture (i.e., constant values under any arm posture). Arm stiffness during transverse movement was considerably greater than that during corresponding posture, but not during a longitudinal movement. Although the ratios of elbow, shoulder, and double-joint stiffness were varied in time, the orientation of stiffness ellipses during the movement did not change much. Equilibrium-point trajectories that were predicted from measured stiffness parameters and actual trajectories were slightly sinusoidally curved in Cartesian space and their velocity profiles were quite different from the velocity profiles of actual hand trajectories. This result contradicts the hypothesis that the brain does not take the dynamics into account in movement control depending on the neuromuscular servo mechanism; rather, it implies that the brain needs to acquire some internal models of controlled objects.

  14. Data Management Considerations for the International Polar Year

    NASA Astrophysics Data System (ADS)

    Parsons, M. A.; Weaver, R. L.; Duerr, R.; Barry, R. G.

    2004-12-01

    The legacy of the International Geophysical Year and past International Polar Years is in the scientific data collected. The upcoming IPY will result in an unprecedented collection of geophysical and social science data from the polar regions. To realize the full scientific and interdisciplinary utility of these data it is essential to consider the design of data management systems early in the expirimental planning process. This paper will present an array of high level data management considerations for the IPY including cross-disciplinary data access, essential documentation, system guidance, and long-term data archiving. Specific recommendations from relevant international organizations such as the Joint Committee on Antarctic Data Management and the WCRP Climate and Cryosphere Programme will be considered. The potential role of the Electronic Geophysical Year and other International Years will also be discussed.

  15. Joint Kinetics to Assess the Influence of the Racket on a Tennis Player’s Shoulder

    PubMed Central

    Creveaux, Thomas; Dumas, Raphaël; Hautier, Christophe; Macé, Pierre; Chèze, Laurence; Rogowski, Isabelle

    2013-01-01

    This study aimed at investigating the influence of three rackets on shoulder net joint moments, power and muscle activity during the flat tennis serve under field- conditions. A 6-camera Eagle® motion analysis system, operating at 256 Hz, captured racket and dominant upper limb kinematics of the serve in five tennis players under three racket conditions (A: low mass, high balance and polar moment, B: low three moments of inertia, and C: high mass, swingweight and twistweight). The electromyographic activity of six trunk and arm muscles was simultaneously recorded. Shoulder net joint moments and power were computed by 3D inverse dynamics. The results showed that greater shoulder joint power and internal/external rotation peak moments were found to accelerate and decelerate racket A in comparison with the racket C. Moreover, serving with the racket A resulted in less activity in latissimus dorsi muscle during the acceleration phase, and biceps brachii muscle during the follow-through phase when compared with racket C. These initial findings encourage studying the biomechanical measurements to quantify the loads on the body during play in order to reduce them, and then prevent shoulder injuries. Racket specifications may be a critical point for coaches who train players suffering from shoulder pain and chronic upper limb injuries should be considered in relation to the racket specifications of the players. Key Points Light racket required more joint power than heavy one to achieve similar post impact ball velocity. Serving with a light racket resulted in higher shoulder internal and external rotation moments than using a heavy one for similar performance. Chronic shoulder pain should encourage coaches to check for potentially inappropriate racket specifications of their players. PMID:24149804

  16. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    PubMed

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  17. Focus on China. Joint Force Quarterly, Issue 47, 4th Quarter 2007

    DTIC Science & Technology

    2007-01-01

    and the informa- tion age —is creating a paper dragon. This issue of Joint Force Quarterly takes a look at China and Sino-U.S. engagement, as well...Golden Age because “forthwith, multitudes would resort to his dominions.”26 Confucius likened this dynamic almost to an irresistible force of...China’s support from an international perspective. China only recently became comfortable in its “liberal internationalist skin ,” but it has since

  18. JointMMCC: Joint Maximum-Margin Classification and Clustering of Imaging Data

    PubMed Central

    Filipovych, Roman; Resnick, Susan M.; Davatzikos, Christos

    2012-01-01

    A number of conditions are characterized by pathologies that form continuous or nearly-continuous spectra spanning from the absence of pathology to very pronounced pathological changes (e.g., normal aging, Mild Cognitive Impairment, Alzheimer's). Moreover, diseases are often highly heterogeneous with a number of diagnostic subcategories or subconditions lying within the spectra (e.g., Autism Spectrum Disorder, schizophrenia). Discovering coherent subpopulations of subjects within the spectrum of pathological changes may further our understanding of diseases, and potentially identify subconditions that require alternative or modified treatment options. In this paper, we propose an approach that aims at identifying coherent subpopulations with respect to the underlying MRI in the scenario where the condition is heterogeneous and pathological changes form a continuous spectrum. We describe a Joint Maximum-Margin Classification and Clustering (JointMMCC) approach that jointly detects the pathologic population via semi-supervised classification, as well as disentangles heterogeneity of the pathological cohort by solving a clustering subproblem. We propose an efficient solution to the non-convex optimization problem associated with JointMMCC. We apply our proposed approach to an MRI study of aging, and identify coherent subpopulations (i.e., clusters) of cognitively less stable adults. PMID:22328179

  19. Minimally invasive arthrodesis for chronic sacroiliac joint dysfunction using the SImmetry SI Joint Fusion system

    PubMed Central

    Miller, Larry E; Block, Jon E

    2014-01-01

    Chronic sacroiliac (SI) joint-related low back pain (LBP) is a common, yet under-diagnosed and undertreated condition due to difficulties in accurate diagnosis and highly variable treatment practices. In patients with debilitating SI-related LBP for at least 6 months duration who have failed conservative management, arthrodesis is a viable option. The SImmetry® SI Joint Fusion System is a novel therapy for SI joint fusion, not just fixation, which utilizes a minimally invasive surgical approach, instrumented fixation for immediate stability, and joint preparation with bone grafting for a secure construct in the long term. The purpose of this report is to describe the minimally invasive SI Joint Fusion System, including patient selection criteria, implant characteristics, surgical technique, postoperative recovery, and biomechanical testing results. Advantages and limitations of this system will be discussed. PMID:24851059

  20. HMA Longitudinal Joint Evaluation and Construction

    DOT National Transportation Integrated Search

    2011-02-01

    Longitudinal joint quality is essential to the successful performance of asphalt pavements. A number of states have begun to implement longitudinal joint specifications, and most are based on determinations of density. However, distress at the joint ...

  1. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  2. Chaperonin containing T-complex polypeptide subunit eta is a potential marker of joint contracture: an experimental study in the rat.

    PubMed

    He, Ronghan; Wang, Zhe; Lu, Yunxiang; Huang, Junqi; Ren, Jianhua; Wang, Kun

    2015-11-01

    Joint contracture is a fibroproliferative disorder that restricts joint mobility, resulting in tissue degeneration and deformity. However, the etiology of joint contracture is still unknown. Chaperonin containing T-complex polypeptide subunit eta (CCT-eta) is reported to increase in fibrotic diseases. The purpose of this study was to investigate whether CCT-eta is implicated in joint contracture and to determine the role of CCT-eta in the progression of joint contracture by analyzing a rat model. We immobilized the left knee joint of rat by internal fixation for 8 weeks. The non-immobilized right leg served as a control. The range of motion (ROM) of the knee was investigated. Fibroblasts were obtained from the posterior joint capsule of the joints. The outcome was followed by quantitative real-time polymerase chain reaction (qRT-PCR), Western blot, fibroblast migration assay, and collagen assay. The effect of CCT-eta on the functions of fibroblasts was observed by utilizing a short inhibitory RNA (siRNA) targeting CCT-eta. The ROM of the immobilized joints was significantly limited compared to the contralateral joints (p < 0.05). Fibroblasts derived from the contractive joints showed higher mRNA and protein expressions of CCT-eta in parallel with alpha-smooth muscle actin (α-SMA) compared to the cells from the contralateral knees (p < 0.05). siRNA-mediated downregulation of CCT-eta inhibited the expressions of both CCT-eta and α-SMA. Moreover, the reduction of CCT-eta also significantly decreased fibroblast functions such as cell mobility and collagen synthesis (all p < 0.05). Our findings indicate that CCT-eta appears to be a potential marker of joint contracture disease.

  3. Joint principal trend analysis for longitudinal high-dimensional data.

    PubMed

    Zhang, Yuping; Ouyang, Zhengqing

    2018-06-01

    We consider a research scenario motivated by integrating multiple sources of information for better knowledge discovery in diverse dynamic biological processes. Given two longitudinal high-dimensional datasets for a group of subjects, we want to extract shared latent trends and identify relevant features. To solve this problem, we present a new statistical method named as joint principal trend analysis (JPTA). We demonstrate the utility of JPTA through simulations and applications to gene expression data of the mammalian cell cycle and longitudinal transcriptional profiling data in response to influenza viral infections. © 2017, The International Biometric Society.

  4. Method of forming a joint

    DOEpatents

    Butt, Darryl Paul; Cutler, Raymond Ashton; Rynders, Steven Walton; Carolan, Michael Francis

    2006-08-22

    A method of joining at least two sintered bodies to form a composite structure, including providing a first multicomponent metallic oxide having a perovskitic or fluorite crystal structure; providing a second sintered body including a second multicomponent metallic oxide having a crystal structure of the same type as the first; and providing at an interface a joint material containing at least one metal oxide containing at least one metal identically contained in at least one of the first and second multicomponent metallic oxides. The joint material is free of cations of Si, Ge, Sn, Pb, P and Te and has a melting point below the sintering temperatures of both sintered bodies. The joint material is heated to a temperature above the melting point of the metal oxide(s) and below the sintering temperatures of the sintered bodies to form the joint. Structures containing such joints are also disclosed.

  5. RSRM Nozzle-to-Case Joint J-leg Development

    NASA Technical Reports Server (NTRS)

    Albrechtsen, Kevin U.; Eddy, Norman F.; Ewing, Mark E.; McGuire, John R.

    2003-01-01

    Since the beginning of the Space Shuttle Reusable Solid Rocket Motor (RSRM) program, nozzle-to-case joint polysulfide adhesive gas paths have occurred on several flight motors. These gas paths have allowed hot motor gases to reach the wiper O-ring. Even though these motors continue to fly safely with this condition, a desire was to reduce such occurrences. The RSRM currently uses a J-leg joint configuration on case field joints and igniter inner and outer joints. The J-leg joint configuration has been successfully demonstrated on numerous RSRM flight and static test motors, eliminating hot gas intrusion to the critical O-ring seals on these joints. Using the proven technology demonstrated on the case field joints and igniter joints, a nozzle-to-case joint J-leg design was developed for implementation on RSRM flight motors. This configuration provides an interference fit with nozzle fixed housing phenolics at assembly, with a series of pressurization gaps incorporated outboard of the joint mating surface to aid in joint pressurization and to eliminate any circumferential flow in this region. The joint insulation is bonded to the nozzle phenolics using the same pressure sensitive adhesive used in the case field joints and igniter joints. An enhancement to the nozzle-to-case joint J-leg configuration is the implementation of a carbon rope thermal barrier. The thermal barrier is located downstream of the joint bondline and is positioned within the joint in a manner where any hot gas intrusion into the joint passes through the thermal barrier, reducing gas temperatures to a level that would not affect O-rings downstream of the thermal barrier. This paper discusses the processes used in reaching a final nozzle-to-case joint J-leg design, provides structural and thermal results in support of the design, and identifies fabrication techniques and demonstrations used in arriving at the final configuration.

  6. Opportunities for international collaboration in industrial pollution prevention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, J.K.; Fowler, K.M.

    1993-08-01

    The goal of this paper is to describe international research opportunities for in-process reduction of wastes from industrial processes. Written responses from 52 researchers were obtained from 15 different countries in mid-1992. Each researcher provided information about products to reduce waste in industrial processes and recommended joint activities and mechanisms for working collaboratively with the United States.

  7. Rotary Joints With Electrical Connections

    NASA Technical Reports Server (NTRS)

    Osborn, F. W.

    1986-01-01

    Power and data transmitted on many channels. Two different rotary joints equipped with electrical connections between rotating and stationary parts. One joint transmits axial thrust and serves as interface between spinning and nonspinning parts of Galileo spacecraft. Other is scanning (limitedrotation) joint that aims scientific instruments from nonspinning part. Selected features of both useful to designers of robots, advanced production equipment, and remotely controlled instruments.

  8. Simplified Chinese version of the Forgotten Joint Score (FJS) for patients who underwent joint arthroplasty: cross-cultural adaptation and validation.

    PubMed

    Cao, Shiqi; Liu, Ning; Han, Wuxiang; Zi, Yunpeng; Peng, Fan; Li, Lexiang; Fu, Qiwei; Chen, Yi; Zheng, Weijie; Qian, Qirong

    2017-01-14

    The Forgotten Joint Score (FJS) is a newly developed health-related quality of life (HRQoL) questionnaire designed to evaluate the awareness after total knee arthroplasty (TKA). This study cross-culturally adapted and psychometrically validated a simplified Chinese version of the FJS (SC-FJS). Cross-cultural adaptation was performed according to the internationally recognized guidelines. One-hundred and fifty participants who underwent primary TKA were recruited in this study. Cronbach's α and intra-class correlations were used to determine reliability. Construct validity was analyzed by evaluating the correlations between SC-FJS and the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the short form (36) health survey (SF-36). Each of the 12 items was properly responded and correlated with the total items. SC-FJS had excellent reliability [Cronbach's α = 0.907, intra-class correlation coefficient (ICC) = 0.970, 95% CI 0.959-0.978). Elimination of any one item in all did not result in a value of Cronbach's α of <0.80. SC-FJS had a high correlation with symptoms (0.67, p < 0.001) and pain (0.60, p < 0.001) domains of KOOS and social functioning (0.66, p < 0.001) domain of SF-36, and it also moderately correlated with function in daily living (0.53, p < 0.001) and function in sport and recreation (0.40, p < 0.001) domains of KOOS, and physical subscale of SF-36 (0.49-0.53, p < 0.001) but had a low (r = 0.20) or not significant (p > 0.05) correlation with mental subscale of SF-36. SC-FJS demonstrated excellent acceptability, internal consistency, reliability, and construct validity, which can be recommended for patients who underwent joint arthroplasty in Mainland China.

  9. Prosthetic Joint Infections

    PubMed Central

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  10. Shea Nut Oil Triterpene Concentrate Attenuates Knee Osteoarthritis Development in Rats: Evidence from Knee Joint Histology.

    PubMed

    Kao, Jen-Hsin; Lin, Sheng-Hsiung; Lai, Chun-Fu; Lin, Yu-Chieh; Kong, Zwe-Ling; Wong, Chih-Shung

    2016-01-01

    Shea nut oil triterpene concentrate is considered to have anti-inflammatory and antioxidant properties. Traditionally, it has been used to treat arthritic conditions in humans. This study aimed to investigate the effect of attenuating osteoarthritis (OA)-induced pain and joint destruction in rats by administering shea nut oil triterpene concentrate (SheaFlex75, which is more than 50% triterpenes). An anterior cruciate ligament transaction (ACLT) with medial meniscectomy (MMx) was used to induce OA in male Wistar rats. Different doses of SheaFlex75 (111.6 mg/kg, 223.2 mg/kg, and 446.4 mg/kg) were then intragastrically administered daily for 12 weeks after surgery. Body weight and the width of the knee joint were measured weekly. Additionally, incapacitance tests were performed at weeks 2, 4, 6, 8, 10 and 12 to measure the weight bearing of the hind limbs, and the morphology and histopathology of the medial femoral condyles were examined and were evaluated using the Osteoarthritis Research Society International (OARSI) scoring system. This study showed that SheaFlex75 reduced the swelling of the knee joint with OA and rectified its weight bearing after ACLT plus MMx surgery in rats. Treatment with SheaFlex75 also decreased ACLT plus MMx surgery-induced knee joint matrix loss and cartilage degeneration. SheaFlex75 relieves the symptoms of OA and protects cartilage from degeneration. SheaFlex75 thus has the potential to be an ideal nutraceutical supplement for joint protection, particularly for injured knee joints.

  11. Induction of osteoarthritis by injecting monosodium iodoacetate into the patellofemoral joint of an experimental rat model.

    PubMed

    Takahashi, Ikufumi; Matsuzaki, Taro; Kuroki, Hiroshi; Hoso, Masahiro

    2018-01-01

    This study aimed to investigate the histopathological changes in the patellofemoral joint using a rat model of osteoarthritis that was induced using monosodium iodoacetate, and to establish a novel model of patellofemoral osteoarthritis in a rat model using histopathological analysis. Sixty male rats were used. Osteoarthritis was induced through a single intra-articular injection of monosodium iodoacetate in both knee joints. Animals were equally divided into two experimental groups based on the monosodium iodoacetate dose: 0.2 mg and 1.0 mg. Histopathological changes in the articular cartilage of the patellofemoral joint and the infrapatellar fat pad were examined at 3 days, 1 week, 2 weeks, 4 weeks, 8 weeks, and 12 weeks after the monosodium iodoacetate injection. In the 1.0-mg group, the representative histopathological findings of osteoarthritis were observed in the articular cartilage of the patellofemoral joint over time. Additionally, the Osteoarthritis Research Society International scores of the patellofemoral joint increased over time. The synovitis scores of the infrapatellar fat pad in both groups were highest at 3 days, and then the values decreased over time. The fibrosis score of the infrapatellar fat pad in the 1.0-mg group increased with time, whereas the fibrosis score in the 0.2-mg group remained low. Representative histopathological findings of osteoarthritis were observed in the articular cartilage of the patellofemoral joint in a rat model of osteoarthritis induced using monosodium iodoacetate. With appropriate selection, this model may be regarded as an ideal patellofemoral osteoarthritis model.

  12. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  13. Adhesive-bonded scarf and stepped-lap joints

    NASA Technical Reports Server (NTRS)

    Hart-Smith, L. J.

    1973-01-01

    Continuum mechanics solutions are derived for the static load-carrying capacity of scarf and stepped-lap adhesive-bonded joints. The analyses account for adhesive plasticity and adherend stiffness imbalance and thermal mismatch. The scarf joint solutions include a simple algebraic formula which serves as a close lower bound, within a small fraction of a per cent of the true answer for most practical geometries and materials. Digital computer programs were developed and, for the stepped-lap joints, the critical adherend and adhesive stresses are computed for each step. The scarf joint solutions exhibit grossly different behavior from that for double-lap joints for long overlaps inasmuch as that the potential bond shear strength continues to increase with indefinitely long overlaps on the scarf joints. The stepped-lap joint solutions exhibit some characteristics of both the scarf and double-lap joints. The stepped-lap computer program handles arbitrary (different) step lengths and thickness and the solutions obtained have clarified potentially weak design details and the remedies. The program has been used effectively to optimize the joint proportions.

  14. Treatment of Early Post-Op Wound Infection after Internal Fixation

    DTIC Science & Technology

    2017-10-01

    the fracture stable while the bone heals. Approximately 10%-40% of severe fractures fixed with internal fixation develop a deep wound infection during...effect of treatment of post-op wound infection in bones after fracture fixation or joint fusion and either: (Group 1) operative debridement and PO

  15. Telework 96: An International Collaborative Learning Package for Information Entrepreneurs.

    ERIC Educational Resources Information Center

    Davenport, Elisabeth; Wormell, Irene

    1997-01-01

    Describes the implementation of an international joint course developed by Queen Margaret College in Scotland and the Royal School of Librarianship in Denmark introducing undergraduate students to tools and issues relevant to teleworking, or working at home. Discusses course objectives, class assignments, student assessment, and program…

  16. INTERNATIONAL ENVIRONMENTAL TECHNOLOGY IDENTIFICATION, DEVELOPMENT, DEMONSTRATION, DEPLOYMENT AND EXCHANGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roy C. Herndon

    2001-02-28

    Cooperative Agreement (DE-FC21-95EW55101) between the U.S. Department of Energy (DOE) and the Florida State University's Institute for International Cooperative Environmental Research (IICER) was designed to facilitate a number of joint programmatic goals of both the DOE and the IICER related to international technology identification, development, demonstration and deployment using a variety of mechanisms to accomplish these goals. These mechanisms included: laboratory and field research; technology demonstrations; international training and technical exchanges; data collection, synthesis and evaluation; the conduct of conferences, symposia and high-level meetings; and other appropriate and effective approaches. The DOE utilized the expertise and facilities of the IICERmore » at Florida State University to accomplish its goals related to this cooperative agreement. The IICER has unique and demonstrated capabilities that have been utilized to conduct the tasks for this cooperative agreement. The IICER conducted activities related to technology identification, development, evaluation, demonstration and deployment through its joint centers which link the capabilities at Florida State University with collaborating academic and leading research institutions in the major countries of Central and Eastern Europe (e.g., Czech Republic, Hungary, Poland) and Russia. The activities and accomplishments for this five-year cooperative agreement are summarized in this Final Technical Report.« less

  17. Dynamic Analyses Including Joints Of Truss Structures

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith

    1991-01-01

    Method for mathematically modeling joints to assess influences of joints on dynamic response of truss structures developed in study. Only structures with low-frequency oscillations considered; only Coulomb friction and viscous damping included in analysis. Focus of effort to obtain finite-element mathematical models of joints exhibiting load-vs.-deflection behavior similar to measured load-vs.-deflection behavior of real joints. Experiments performed to determine stiffness and damping nonlinearities typical of joint hardware. Algorithm for computing coefficients of analytical joint models based on test data developed to enable study of linear and nonlinear effects of joints on global structural response. Besides intended application to large space structures, applications in nonaerospace community include ground-based antennas and earthquake-resistant steel-framed buildings.

  18. Joint contact forces can be reduced by improving joint moment symmetry in below-knee amputee gait simulations.

    PubMed

    Koelewijn, Anne D; van den Bogert, Antonie J

    2016-09-01

    Despite having a fully functional knee and hip in both legs, asymmetries in joint moments of the knee and hip are often seen in gait of persons with a unilateral transtibial amputation (TTA), possibly resulting in excessive joint loading. We hypothesize that persons with a TTA can walk with more symmetric joint moments at the cost of increased effort or abnormal kinematics. The hypothesis was tested using predictive simulations of gait. Open loop controls of one gait cycle were found by solving an optimization problem that minimizes a combination of walking effort and tracking error in joint angles, ground reaction force and gait cycle duration. A second objective was added to penalize joint moment asymmetry, creating a multi-objective optimization problem. A Pareto front was constructed by changing the weights of the objectives and three solutions were analyzed to study the effect of increasing joint moment symmetry. When the optimization placed more weight on moment symmetry, walking effort increased and kinematics became less normal, confirming the hypothesis. TTA gait improved with a moderate increase in joint moment symmetry. At a small cost of effort and abnormal kinematics, the peak hip extension moment in the intact leg was decreased significantly, and so was the joint contact force in the knee and hip. Additional symmetry required a significant increase in walking effort and the joint contact forces in both hips became significantly higher than in able-bodied gait. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Paradoxical effects of the cannabinoid CB2 receptor agonist GW405833 on rat osteoarthritic knee joint pain.

    PubMed

    Schuelert, N; Zhang, C; Mogg, A J; Broad, L M; Hepburn, D L; Nisenbaum, E S; Johnson, M P; McDougall, J J

    2010-11-01

    The present study examined whether local administration of the cannabinoid-2 (CB(2)) receptor agonist GW405833 could modulate joint nociception in control rat knee joints and in an animal model of osteoarthritis (OA). OA was induced in male Wistar rats by intra-articular injection of sodium monoiodo-acetate with a recovery period of 14 days. Immunohistochemistry was used to evaluate the expression of CB(2) and transient receptor potential vanilloid channel-1 (TRPV1) receptors in the dorsal root ganglion (DRG) and synovial membrane of sham- and sodium mono-iodoacetate (MIA)-treated animals. Electrophysiological recordings were made from knee joint primary afferents in response to rotation of the joint both before and following close intra-arterial injection of different doses of GW405833. The effect of intra-articular GW405833 on joint pain perception was determined by hindlimb incapacitance. An in vitro neuronal release assay was used to see if GW405833 caused release of an inflammatory neuropeptide (calcitonin gene-related peptide - CGRP). CB(2) and TRPV1 receptors were co-localized in DRG neurons and synoviocytes in both sham- and MIA-treated animals. Local application of the GW405833 significantly reduced joint afferent firing rate by up to 31% in control knees. In OA knee joints, however, GW405833 had a pronounced sensitising effect on joint mechanoreceptors. Co-administration of GW405833 with the CB(2) receptor antagonist AM630 or pre-administration of the TRPV1 ion channel antagonist SB366791 attenuated the sensitising effect of GW405833. In the pain studies, intra-articular injection of GW405833 into OA knees augmented hindlimb incapacitance, but had no effect on pain behaviour in saline-injected control joints. GW405833 evoked increased CGRP release via a TRPV1 channel-dependent mechanism. These data indicate that GW405833 reduces the mechanosensitivity of afferent nerve fibres in control joints but causes nociceptive responses in OA joints. The observed

  20. Single stage treatment of ankylosis of the temporomandibular joint using patient-specific total joint replacement and virtual surgical planning.

    PubMed

    Haq, Jahrad; Patel, Nishma; Weimer, Katherine; Matthews, N Shaun

    2014-04-01

    Ankylosis of the temporomandibular joint (TMJ) is a debilitating condition that can result in pain, trismus, and a poor quality of life. It can be caused by injury, infection, and rheumatoid disease. Current management includes gap arthroplasty, interpositional arthroplasty, and reconstruction. Traditionally, joints are reconstructed using stock implants, or the procedure is done in two stages with an additional computed tomography (CT) scan between the resective and reconstructive procedures and use of stereolithographic models to aid the design of the definitive prostheses. We describe a technique for the resection of ankylosis and reconstruction of the joint in a single operation using virtually designed custom-made implants. Five patients with ankylosis of the TMJ had a single stage operation with reconstruction between 2010 and 2012. All had preoperative high-resolution CT with contrast angiography. During an international web-based teleconference between the surgeon and the engineer a virtual resection of the ankylosis was done using the reconstructed CT images. The bespoke cutting guides and implants were designed virtually at the same time and were then manufactured precisely using computer-aided design and manufacture (CAD-CAM) over 6 weeks. After release of the ankylosis and reconstruction, the patients underwent an exercise regimen to improve mouth opening. Follow-up was for a minimum of 6 months. Four patients had one operation, and one patient had two. Median/Mean maximum incisal opening increased from 0.6mm before operation to 25 mm afterwards (range 23-27), and there was minimal surgical morbidity. This new method effectively treats ankylosis of the TMJ in a single stage procedure. Fewer operations and hospital stays, and the maintenance of overall clinical outcome are obvious advantages. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.