Sample records for joint modeling techniques

  1. Comparative evaluation between anatomic and non-anatomic lateral ligament reconstruction techniques in the ankle joint: A computational study.

    PubMed

    Purevsuren, Tserenchimed; Batbaatar, Myagmarbayar; Khuyagbaatar, Batbayar; Kim, Kyungsoo; Kim, Yoon Hyuk

    2018-03-12

    Biomechanical studies have indicated that the conventional non-anatomic reconstruction techniques for lateral ankle sprain (LAS) tend to restrict subtalar joint motion compared to intact ankle joints. Excessive restriction in subtalar motion may lead to chronic pain, functional difficulties, and development of osteoarthritis. Therefore, various anatomic surgical techniques to reconstruct both the anterior talofibular and calcaneofibular ligaments have been introduced. In this study, ankle joint stability was evaluated using multibody computational ankle joint model to assess two new anatomic reconstruction and three popular non-anatomic reconstruction techniques. An LAS injury, three popular non-anatomic reconstruction models (Watson-Jones, Evans, and Chrisman-Snook), and two common types of anatomic reconstruction models were developed based on the intact ankle model. The stability of ankle in both talocrural and subtalar joint were evaluated under anterior drawer test (150 N anterior force), inversion test (3 Nm inversion moment), internal rotational test (3 Nm internal rotation moment), and the combined loading test (9 Nm inversion and internal moment as well as 1800 N compressive force). Our overall results show that the two anatomic reconstruction techniques were superior to the non-anatomic reconstruction techniques in stabilizing both talocrural and subtalar joints. Restricted subtalar joint motion, which mainly observed in Watson-Jones and Chrisman-Snook techniques, was not shown in the anatomical reconstructions. Evans technique was beneficial for subtalar joint as it does not restrict subtalar motion, though Evans technique was insufficient for restoring talocrural joint inversion. The anatomical reconstruction techniques best recovered ankle stability.

  2. Modelling Technique for Demonstrating Gravity Collapse Structures in Jointed Rock.

    ERIC Educational Resources Information Center

    Stimpson, B.

    1979-01-01

    Described is a base-friction modeling technique for studying the development of collapse structures in jointed rocks. A moving belt beneath weak material is designed to simulate gravity. A description is given of the model frame construction. (Author/SA)

  3. In Vivo Measurement of Glenohumeral Joint Contact Patterns

    NASA Astrophysics Data System (ADS)

    Bey, Michael J.; Kline, Stephanie K.; Zauel, Roger; Kolowich, Patricia A.; Lock, Terrence R.

    2009-12-01

    The objectives of this study were to describe a technique for measuring in-vivo glenohumeral joint contact patterns during dynamic activities and to demonstrate application of this technique. The experimental technique calculated joint contact patterns by combining CT-based 3D bone models with joint motion data that were accurately measured from biplane x-ray images. Joint contact patterns were calculated for the repaired and contralateral shoulders of 20 patients who had undergone rotator cuff repair. Significant differences in joint contact patterns were detected due to abduction angle and shoulder condition (i.e., repaired versus contralateral). Abduction angle had a significant effect on the superior/inferior contact center position, with the average joint contact center of the repaired shoulder 12.1% higher on the glenoid than the contralateral shoulder. This technique provides clinically relevant information by calculating in-vivo joint contact patterns during dynamic conditions and overcomes many limitations associated with conventional techniques for quantifying joint mechanics.

  4. Nonlinear Modeling of Joint Dominated Structures

    NASA Technical Reports Server (NTRS)

    Chapman, J. M.

    1990-01-01

    The development and verification of an accurate structural model of the nonlinear joint-dominated NASA Langley Mini-Mast truss are described. The approach is to characterize the structural behavior of the Mini-Mast joints and struts using a test configuration that can directly measure the struts' overall stiffness and damping properties, incorporate this data into the structural model using the residual force technique, and then compare the predicted response with empirical data taken by NASA/LaRC during the modal survey tests of the Mini-Mast. A new testing technique, referred to as 'link' testing, was developed and used to test prototype struts of the Mini-Masts. Appreciable nonlinearities including the free-play and hysteresis were demonstrated. Since static and dynamic tests performed on the Mini-Mast also exhibited behavior consistent with joints having free-play and hysteresis, nonlinear models of the Mini-Mast were constructed and analyzed. The Residual Force Technique was used to analyze the nonlinear model of the Mini-Mast having joint free-play and hysteresis.

  5. Joint Manipulation: Toward a General Theory of High-Velocity, Low-Amplitude Thrust Techniques.

    PubMed

    Harwich, Andrew S

    2017-12-01

    The objective of this study was to describe the initial stage of a generalized theory of high-velocity, low-amplitude thrust (HVLAT) techniques for joint manipulation. This study examined the movements described by authors from the fields of osteopathy, chiropractic, and physical therapy to produce joint cavitation in both the metacarpophalangeal (MCP) joint and the cervical spine apophysial joint. This study qualitatively compared the kinetics, the similarities, and the differences between MCP cavitation and cervical facet joint cavitation. A qualitative vector analysis of forces and movements was undertaken by constructing computer-generated, simplified graphical models of the MCP joint and a typical cervical apophysial joint and imposing the motions dictated by the clinical technique. Comparing the path to cavitation of 2 modes of HVLAT for the MCP joint, namely, distraction and hyperflexion, it was found that the hyperflexion method requires an axis of rotation, the hinge axis, which is also required for cervical HVLAT. These results show that there is an analogue of cervical HVLAT in one of the MCP joint HVLATs. The study demonstrated that in a theoretical model, the path to joint cavitation is the same for asymmetric separation of the joint surfaces in the cervical spine and the MCP joints.

  6. An assessment of finite-element modeling techniques for thick-solid/thin-shell joints analysis

    NASA Technical Reports Server (NTRS)

    Min, J. B.; Androlake, S. G.

    1993-01-01

    The subject of finite-element modeling has long been of critical importance to the practicing designer/analyst who is often faced with obtaining an accurate and cost-effective structural analysis of a particular design. Typically, these two goals are in conflict. The purpose is to discuss the topic of finite-element modeling for solid/shell connections (joints) which are significant for the practicing modeler. Several approaches are currently in use, but frequently various assumptions restrict their use. Such techniques currently used in practical applications were tested, especially to see which technique is the most ideally suited for the computer aided design (CAD) environment. Some basic thoughts regarding each technique are also discussed. As a consequence, some suggestions based on the results are given to lead reliable results in geometrically complex joints where the deformation and stress behavior are complicated.

  7. Scalable Joint Models for Reliable Uncertainty-Aware Event Prediction.

    PubMed

    Soleimani, Hossein; Hensman, James; Saria, Suchi

    2017-08-21

    Missing data and noisy observations pose significant challenges for reliably predicting events from irregularly sampled multivariate time series (longitudinal) data. Imputation methods, which are typically used for completing the data prior to event prediction, lack a principled mechanism to account for the uncertainty due to missingness. Alternatively, state-of-the-art joint modeling techniques can be used for jointly modeling the longitudinal and event data and compute event probabilities conditioned on the longitudinal observations. These approaches, however, make strong parametric assumptions and do not easily scale to multivariate signals with many observations. Our proposed approach consists of several key innovations. First, we develop a flexible and scalable joint model based upon sparse multiple-output Gaussian processes. Unlike state-of-the-art joint models, the proposed model can explain highly challenging structure including non-Gaussian noise while scaling to large data. Second, we derive an optimal policy for predicting events using the distribution of the event occurrence estimated by the joint model. The derived policy trades-off the cost of a delayed detection versus incorrect assessments and abstains from making decisions when the estimated event probability does not satisfy the derived confidence criteria. Experiments on a large dataset show that the proposed framework significantly outperforms state-of-the-art techniques in event prediction.

  8. Joint Optimization of Vertical Component Gravity and Seismic P-wave First Arrivals by Simulated Annealing

    NASA Astrophysics Data System (ADS)

    Louie, J. N.; Basler-Reeder, K.; Kent, G. M.; Pullammanappallil, S. K.

    2015-12-01

    Simultaneous joint seismic-gravity optimization improves P-wave velocity models in areas with sharp lateral velocity contrasts. Optimization is achieved using simulated annealing, a metaheuristic global optimization algorithm that does not require an accurate initial model. Balancing the seismic-gravity objective function is accomplished by a novel approach based on analysis of Pareto charts. Gravity modeling uses a newly developed convolution algorithm, while seismic modeling utilizes the highly efficient Vidale eikonal equation traveltime generation technique. Synthetic tests show that joint optimization improves velocity model accuracy and provides velocity control below the deepest headwave raypath. Detailed first arrival picking followed by trial velocity modeling remediates inconsistent data. We use a set of highly refined first arrival picks to compare results of a convergent joint seismic-gravity optimization to the Plotrefa™ and SeisOpt® Pro™ velocity modeling packages. Plotrefa™ uses a nonlinear least squares approach that is initial model dependent and produces shallow velocity artifacts. SeisOpt® Pro™ utilizes the simulated annealing algorithm and is limited to depths above the deepest raypath. Joint optimization increases the depth of constrained velocities, improving reflector coherency at depth. Kirchoff prestack depth migrations reveal that joint optimization ameliorates shallow velocity artifacts caused by limitations in refraction ray coverage. Seismic and gravity data from the San Emidio Geothermal field of the northwest Basin and Range province demonstrate that joint optimization changes interpretation outcomes. The prior shallow-valley interpretation gives way to a deep valley model, while shallow antiformal reflectors that could have been interpreted as antiformal folds are flattened. Furthermore, joint optimization provides a clearer image of the rangefront fault. This technique can readily be applied to existing datasets and could replace the existing strategy of forward modeling to match gravity data.

  9. Adaptive torque estimation of robot joint with harmonic drive transmission

    NASA Astrophysics Data System (ADS)

    Shi, Zhiguo; Li, Yuankai; Liu, Guangjun

    2017-11-01

    Robot joint torque estimation using input and output position measurements is a promising technique, but the result may be affected by the load variation of the joint. In this paper, a torque estimation method with adaptive robustness and optimality adjustment according to load variation is proposed for robot joint with harmonic drive transmission. Based on a harmonic drive model and a redundant adaptive robust Kalman filter (RARKF), the proposed approach can adapt torque estimation filtering optimality and robustness to the load variation by self-tuning the filtering gain and self-switching the filtering mode between optimal and robust. The redundant factor of RARKF is designed as a function of the motor current for tolerating the modeling error and load-dependent filtering mode switching. The proposed joint torque estimation method has been experimentally studied in comparison with a commercial torque sensor and two representative filtering methods. The results have demonstrated the effectiveness of the proposed torque estimation technique.

  10. Quantification of joint inflammation in rheumatoid arthritis by time-resolved diffuse optical spectroscopy and tracer kinetic modeling

    NASA Astrophysics Data System (ADS)

    Ioussoufovitch, Seva; Morrison, Laura B.; Lee, Ting-Yim; St. Lawrence, Keith; Diop, Mamadou

    2015-03-01

    Rheumatoid arthritis (RA) is characterized by chronic synovial inflammation, which can cause progressive joint damage and disability. Diffuse optical spectroscopy (DOS) and imaging have the potential to become potent monitoring tools for RA. We devised a method that combined time-resolved DOS and tracer kinetics modeling to rapidly and reliably quantify blood flow in the joint. Preliminary results obtained from two animals show that the technique can detect joint inflammation as early as 5 days after onset.

  11. Dual resin bonded joints in polyetheretherketone (PEEK) matrix composites

    NASA Astrophysics Data System (ADS)

    Zelenak, Steve; Radford, Donald W.; Dean, Michael W.

    1993-04-01

    The paper describes applications of the dual resin (miscible polymer) bonding technique (Smiley, 1989) developed as an alternative to traditional bonding approaches to joining thermoplastic matrix composite subassemblies into structures. In the experiments, the performance of joint geometries, such as those that could be used to assemble large truss structures in space, are investigated using truss joint models consisting of woven carbon fiber/PEEK tubes of about 1 mm wall thickness. Specific process conditions and hand-held hardware used to apply heat and pressure were chosen to simulate a field asembly technique. Results are presented on tube/cruciform double lap shear tests, pinned-pinned tube compression tests, and single lap shear bond tests of joints obtained using the dual resin bonding technique.

  12. Time-lapse joint inversion of geophysical data with automatic joint constraints and dynamic attributes

    NASA Astrophysics Data System (ADS)

    Rittgers, J. B.; Revil, A.; Mooney, M. A.; Karaoulis, M.; Wodajo, L.; Hickey, C. J.

    2016-12-01

    Joint inversion and time-lapse inversion techniques of geophysical data are often implemented in an attempt to improve imaging of complex subsurface structures and dynamic processes by minimizing negative effects of random and uncorrelated spatial and temporal noise in the data. We focus on the structural cross-gradient (SCG) approach (enforcing recovered models to exhibit similar spatial structures) in combination with time-lapse inversion constraints applied to surface-based electrical resistivity and seismic traveltime refraction data. The combination of both techniques is justified by the underlying petrophysical models. We investigate the benefits and trade-offs of SCG and time-lapse constraints. Using a synthetic case study, we show that a combined joint time-lapse inversion approach provides an overall improvement in final recovered models. Additionally, we introduce a new approach to reweighting SCG constraints based on an iteratively updated normalized ratio of model sensitivity distributions at each time-step. We refer to the new technique as the Automatic Joint Constraints (AJC) approach. The relevance of the new joint time-lapse inversion process is demonstrated on the synthetic example. Then, these approaches are applied to real time-lapse monitoring field data collected during a quarter-scale earthen embankment induced-piping failure test. The use of time-lapse joint inversion is justified by the fact that a change of porosity drives concomitant changes in seismic velocities (through its effect on the bulk and shear moduli) and resistivities (through its influence upon the formation factor). Combined with the definition of attributes (i.e. specific characteristics) of the evolving target associated with piping, our approach allows localizing the position of the preferential flow path associated with internal erosion. This is not the case using other approaches.

  13. Comparison of Quadrapolar™ radiofrequency lesions produced by standard versus modified technique: an experimental model.

    PubMed

    Safakish, Ramin

    2017-01-01

    Lower back pain (LBP) is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI) joint pain is responsible for LBP in 18%-30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques.

  14. A novel ultrasound technique for detection of osteochondral defects in the ankle joint: a parametric and feasibility study.

    PubMed

    Sarkalkan, Nazli; Loeve, Arjo J; van Dongen, Koen W A; Tuijthof, Gabrielle J M; Zadpoor, Amir A

    2014-12-24

    (Osteo)chondral defects (OCDs) in the ankle are currently diagnosed with modalities that are not convenient to use in long-term follow-ups. Ultrasound (US) imaging, which is a cost-effective and non-invasive alternative, has limited ability to discriminate OCDs. We aim to develop a new diagnostic technique based on US wave propagation through the ankle joint. The presence of OCDs is identified when a US signal deviates from a reference signal associated with the healthy joint. The feasibility of the proposed technique is studied using experimentally-validated 2D finite-difference time-domain models of the ankle joint. The normalized maximum cross correlation of experiments and simulation was 0.97. Effects of variables relevant to the ankle joint, US transducers and OCDs were evaluated. Variations in joint space width and transducer orientation made noticeable alterations to the reference signal: normalized root mean square error ranged from 6.29% to 65.25% and from 19.59% to 8064.2%, respectively. The results suggest that the new technique could be used for detection of OCDs, if the effects of other parameters (i.e., parameters related to the ankle joint and US transducers) can be reduced.

  15. Using a Polytope to Estimate Efficient Production Functions of Joint Product Processes.

    ERIC Educational Resources Information Center

    Simpson, William A.

    In the last decade, a modeling technique has been developed to handle complex input/output analyses where outputs involve joint products and there are no known mathematical relationships linking the outputs or inputs. The technique uses the geometrical concept of a six-dimensional shape called a polytope to analyze the efficiency of each…

  16. A Digital Image-Based Discrete Fracture Network Model and Its Numerical Investigation of Direct Shear Tests

    NASA Astrophysics Data System (ADS)

    Wang, Peitao; Cai, Meifeng; Ren, Fenhua; Li, Changhong; Yang, Tianhong

    2017-07-01

    This paper develops a numerical approach to determine the mechanical behavior of discrete fractures network (DFN) models based on digital image processing technique and particle flow code (PFC2D). A series of direct shear tests of jointed rocks were numerically performed to study the effect of normal stress, friction coefficient and joint bond strength on the mechanical behavior of joint rock and evaluate the influence of micro-parameters on the shear properties of jointed rocks using the proposed approach. The complete shear stress-displacement curve of the DFN model under direct shear tests was presented to evaluate the failure processes of jointed rock. The results show that the peak and residual strength are sensitive to normal stress. A higher normal stress has a greater effect on the initiation and propagation of cracks. Additionally, an increase in the bond strength ratio results in an increase in the number of both shear and normal cracks. The friction coefficient was also found to have a significant influence on the shear strength and shear cracks. Increasing in the friction coefficient resulted in the decreasing in the initiation of normal cracks. The unique contribution of this paper is the proposed modeling technique to simulate the mechanical behavior of jointed rock mass based on particle mechanics approaches.

  17. Seal Analysis for the Ares-I Upper Stage Fuel Tank Manhole Cover

    NASA Technical Reports Server (NTRS)

    Phillips, Dawn R.; Wingate, Robert J.

    2010-01-01

    Techniques for studying the performance of Naflex pressure-assisted seals in the Ares-I Upper Stage liquid hydrogen tank manhole cover seal joint are explored. To assess the feasibility of using the identical seal design for the Upper Stage as was used for the Space Shuttle External Tank manhole covers, a preliminary seal deflection analysis using the ABAQUS commercial finite element software is employed. The ABAQUS analyses are performed using three-dimensional symmetric wedge finite element models. This analysis technique is validated by first modeling a heritage External Tank liquid hydrogen tank manhole cover joint and correlating the results to heritage test data. Once the technique is validated, the Upper Stage configuration is modeled. The Upper Stage analyses are performed at 1.4 times the expected pressure to comply with the Constellation Program factor of safety requirement on joint separation. Results from the analyses performed with the External Tank and Upper Stage models demonstrate the effects of several modeling assumptions on the seal deflection. The analyses for Upper Stage show that the integrity of the seal is successfully maintained.

  18. Getting in shape: Reconstructing three-dimensional long-track speed skating kinematics by comparing several body pose reconstruction techniques.

    PubMed

    van der Kruk, E; Schwab, A L; van der Helm, F C T; Veeger, H E J

    2018-03-01

    In gait studies body pose reconstruction (BPR) techniques have been widely explored, but no previous protocols have been developed for speed skating, while the peculiarities of the skating posture and technique do not automatically allow for the transfer of the results of those explorations to kinematic skating data. The aim of this paper is to determine the best procedure for body pose reconstruction and inverse dynamics of speed skating, and to what extend this choice influences the estimation of joint power. The results show that an eight body segment model together with a global optimization method with revolute joint in the knee and in the lumbosacral joint, while keeping the other joints spherical, would be the most realistic model to use for the inverse kinematics in speed skating. To determine joint power, this method should be combined with a least-square error method for the inverse dynamics. Reporting on the BPR technique and the inverse dynamic method is crucial to enable comparison between studies. Our data showed an underestimation of up to 74% in mean joint power when no optimization procedure was applied for BPR and an underestimation of up to 31% in mean joint power when a bottom-up inverse dynamics method was chosen instead of a least square error approach. Although these results are aimed at speed skating, reporting on the BPR procedure and the inverse dynamics method, together with setting a golden standard should be common practice in all human movement research to allow comparison between studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Strength analysis and design of adhesive joints between circular elements made of metal and reinforced polymer materials

    NASA Astrophysics Data System (ADS)

    Pelekh, B. L.; Marchuk, M. V.; Kogut, I. S.

    1992-06-01

    The stress-strain state of an adhesive joint between cylindrical components made of a metal (steel) and a cross-reinforced filament-wound composite (glass/polymer or basalt/polymer) was investigated under static axial loading using newly proposed experimental techniques and a refined mathematical model. Analytical expressions are obtained for contact stresses in the adhesive joint. The maximum permissible load and the ultimate shear strength of the joint are determined. The experimental results are found to be in satisfactory agreement with model predictions.

  20. Biomechanical testing simulation of a cadaver spine specimen: development and evaluation study.

    PubMed

    Ahn, Hyung Soo; DiAngelo, Denis J

    2007-05-15

    This article describes a computer model of the cadaver cervical spine specimen and virtual biomechanical testing. To develop a graphics-oriented, multibody model of a cadaver cervical spine and to build a virtual laboratory simulator for the biomechanical testing using physics-based dynamic simulation techniques. Physics-based computer simulations apply the laws of physics to solid bodies with defined material properties. This technique can be used to create a virtual simulator for the biomechanical testing of a human cadaver spine. An accurate virtual model and simulation would complement tissue-based in vitro studies by providing a consistent test bed with minimal variability and by reducing cost. The geometry of cervical vertebrae was created from computed tomography images. Joints linking adjacent vertebrae were modeled as a triple-joint complex, comprised of intervertebral disc joints in the anterior region, 2 facet joints in the posterior region, and the surrounding ligament structure. A virtual laboratory simulation of an in vitro testing protocol was performed to evaluate the model responses during flexion, extension, and lateral bending. For kinematic evaluation, the rotation of motion segment unit, coupling behaviors, and 3-dimensional helical axes of motion were analyzed. The simulation results were in correlation with the findings of in vitro tests and published data. For kinetic evaluation, the forces of the intervertebral discs and facet joints of each segment were determined and visually animated. This methodology produced a realistic visualization of in vitro experiment, and allowed for the analyses of the kinematics and kinetics of the cadaver cervical spine. With graphical illustrations and animation features, this modeling technique has provided vivid and intuitive information.

  1. An algorithm for continuum modeling of rocks with multiple embedded nonlinearly-compliant joints [Continuum modeling of elasto-plastic media with multiple embedded nonlinearly-compliant joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurley, R. C.; Vorobiev, O. Y.; Ezzedine, S. M.

    Here, we present a numerical method for modeling the mechanical effects of nonlinearly-compliant joints in elasto-plastic media. The method uses a series of strain-rate and stress update algorithms to determine joint closure, slip, and solid stress within computational cells containing multiple “embedded” joints. This work facilitates efficient modeling of nonlinear wave propagation in large spatial domains containing a large number of joints that affect bulk mechanical properties. We implement the method within the massively parallel Lagrangian code GEODYN-L and provide verification and examples. We highlight the ability of our algorithms to capture joint interactions and multiple weakness planes within individualmore » computational cells, as well as its computational efficiency. We also discuss the motivation for developing the proposed technique: to simulate large-scale wave propagation during the Source Physics Experiments (SPE), a series of underground explosions conducted at the Nevada National Security Site (NNSS).« less

  2. An algorithm for continuum modeling of rocks with multiple embedded nonlinearly-compliant joints [Continuum modeling of elasto-plastic media with multiple embedded nonlinearly-compliant joints

    DOE PAGES

    Hurley, R. C.; Vorobiev, O. Y.; Ezzedine, S. M.

    2017-04-06

    Here, we present a numerical method for modeling the mechanical effects of nonlinearly-compliant joints in elasto-plastic media. The method uses a series of strain-rate and stress update algorithms to determine joint closure, slip, and solid stress within computational cells containing multiple “embedded” joints. This work facilitates efficient modeling of nonlinear wave propagation in large spatial domains containing a large number of joints that affect bulk mechanical properties. We implement the method within the massively parallel Lagrangian code GEODYN-L and provide verification and examples. We highlight the ability of our algorithms to capture joint interactions and multiple weakness planes within individualmore » computational cells, as well as its computational efficiency. We also discuss the motivation for developing the proposed technique: to simulate large-scale wave propagation during the Source Physics Experiments (SPE), a series of underground explosions conducted at the Nevada National Security Site (NNSS).« less

  3. Estimation of Time-Varying, Intrinsic and Reflex Dynamic Joint Stiffness during Movement. Application to the Ankle Joint

    PubMed Central

    Guarín, Diego L.; Kearney, Robert E.

    2017-01-01

    Dynamic joint stiffness determines the relation between joint position and torque, and plays a vital role in the control of posture and movement. Dynamic joint stiffness can be quantified during quasi-stationary conditions using disturbance experiments, where small position perturbations are applied to the joint and the torque response is recorded. Dynamic joint stiffness is composed of intrinsic and reflex mechanisms that act and change together, so that nonlinear, mathematical models and specialized system identification techniques are necessary to estimate their relative contributions to overall joint stiffness. Quasi-stationary experiments have demonstrated that dynamic joint stiffness is heavily modulated by joint position and voluntary torque. Consequently, during movement, when joint position and torque change rapidly, dynamic joint stiffness will be Time-Varying (TV). This paper introduces a new method to quantify the TV intrinsic and reflex components of dynamic joint stiffness during movement. The algorithm combines ensemble and deterministic approaches for estimation of TV systems; and uses a TV, parallel-cascade, nonlinear system identification technique to separate overall dynamic joint stiffness into intrinsic and reflex components from position and torque records. Simulation studies of a stiffness model, whose parameters varied with time as is expected during walking, demonstrated that the new algorithm accurately tracked the changes in dynamic joint stiffness using as little as 40 gait cycles. The method was also used to estimate the intrinsic and reflex dynamic ankle stiffness from an experiment with a healthy subject during which ankle movements were imposed while the subject maintained a constant muscle contraction. The method identified TV stiffness model parameters that predicted the measured torque very well, accounting for more than 95% of its variance. Moreover, both intrinsic and reflex dynamic stiffness were heavily modulated through the movement in a manner that could not be predicted from quasi-stationary experiments. The new method provides the tool needed to explore the role of dynamic stiffness in the control of movement. PMID:28649196

  4. Progressive Damage Analysis of Bonded Composite Joints

    NASA Technical Reports Server (NTRS)

    Leone, Frank A., Jr.; Girolamo, Donato; Davila, Carlos G.

    2012-01-01

    The present work is related to the development and application of progressive damage modeling techniques to bonded joint technology. The joint designs studied in this work include a conventional composite splice joint and a NASA-patented durable redundant joint. Both designs involve honeycomb sandwich structures with carbon/epoxy facesheets joined using adhesively bonded doublers.Progressive damage modeling allows for the prediction of the initiation and evolution of damage within a structure. For structures that include multiple material systems, such as the joint designs under consideration, the number of potential failure mechanisms that must be accounted for drastically increases the complexity of the analyses. Potential failure mechanisms include fiber fracture, intraply matrix cracking, delamination, core crushing, adhesive failure, and their interactions. The bonded joints were modeled using highly parametric, explicitly solved finite element models, with damage modeling implemented via custom user-written subroutines. Each ply was discretely meshed using three-dimensional solid elements. Layers of cohesive elements were included between each ply to account for the possibility of delaminations and were used to model the adhesive layers forming the joint. Good correlation with experimental results was achieved both in terms of load-displacement history and the predicted failure mechanism(s).

  5. Review on failure prediction techniques of composite single lap joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ab Ghani, A.F., E-mail: ahmadfuad@utem.edu.my; Rivai, Ahmad, E-mail: ahmadrivai@utem.edu.my

    2016-03-29

    Adhesive bonding is the most appropriate joining method in construction of composite structures. The use of reliable design and prediction technique will produce better performance of bonded joints. Several papers from recent papers and journals have been reviewed and synthesized to understand the current state of the art in this area. It is done by studying the most relevant analytical solutions for composite adherends with start of reviewing the most fundamental ones involving beam/plate theory. It is then extended to review single lap joint non linearity and failure prediction and finally on the failure prediction on composite single lap joint.more » The review also encompasses the finite element modelling part as tool to predict the elastic response of composite single lap joint and failure prediction numerically.« less

  6. Progressive Damage Modeling of Durable Bonded Joint Technology

    NASA Technical Reports Server (NTRS)

    Leone, Frank A.; Davila, Carlos G.; Lin, Shih-Yung; Smeltzer, Stan; Girolamo, Donato; Ghose, Sayata; Guzman, Juan C.; McCarville, Duglas A.

    2013-01-01

    The development of durable bonded joint technology for assembling composite structures for launch vehicles is being pursued for the U.S. Space Launch System. The present work is related to the development and application of progressive damage modeling techniques to bonded joint technology applicable to a wide range of sandwich structures for a Heavy Lift Launch Vehicle. The joint designs studied in this work include a conventional composite splice joint and a NASA-patented Durable Redundant Joint. Both designs involve a honeycomb sandwich with carbon/epoxy facesheets joined with adhesively bonded doublers. Progressive damage modeling allows for the prediction of the initiation and evolution of damage. For structures that include multiple materials, the number of potential failure mechanisms that must be considered increases the complexity of the analyses. Potential failure mechanisms include fiber fracture, matrix cracking, delamination, core crushing, adhesive failure, and their interactions. The joints were modeled using Abaqus parametric finite element models, in which damage was modeled with user-written subroutines. Each ply was meshed discretely, and layers of cohesive elements were used to account for delaminations and to model the adhesive layers. Good correlation with experimental results was achieved both in terms of load-displacement history and predicted failure mechanisms.

  7. Lithostratigraphic interpretation from joint analysis of seismic tomography and magnetotelluric resistivity models using self-organizing map techniques

    NASA Astrophysics Data System (ADS)

    Bauer, K.; Muñoz, G.; Moeck, I.

    2012-12-01

    The combined interpretation of different models as derived from seismic tomography and magnetotelluric (MT) inversion represents a more efficient approach to determine the lithology of the subsurface compared with the separate treatment of each discipline. Such models can be developed independently or by application of joint inversion strategies. After the step of model generation using different geophysical methodologies, a joint interpretation work flow includes the following steps: (1) adjustment of a joint earth model based on the adapted, identical model geometry for the different methods, (2) classification of the model components (e.g. model blocks described by a set of geophysical parameters), and (3) re-mapping of the classified rock types to visualise their distribution within the earth model, and petrophysical characterization and interpretation. One possible approach for the classification of multi-parameter models is based on statistical pattern recognition, where different models are combined and translated into probability density functions. Classes of rock types are identified in these methods as isolated clusters with high probability density function values. Such techniques are well-established for the analysis of two-parameter models. Alternatively we apply self-organizing map (SOM) techniques, which have no limitations in the number of parameters to be analysed in the joint interpretation. Our SOM work flow includes (1) generation of a joint earth model described by so-called data vectors, (2) unsupervised learning or training, (3) analysis of the feature map by adopting image processing techniques, and (4) application of the knowledge to derive a lithological model which is based on the different geophysical parameters. We show the usage of the SOM work flow for a synthetic and a real data case study. Both tests rely on three geophysical properties: P velocity and vertical velocity gradient from seismic tomography, and electrical resistivity from MT inversion. The synthetic data are used as a benchmark test to demonstrate the performance of the SOM method. The real data were collected along a 40 km profile across parts of the NE German basin. The lithostratigraphic model from the joint SOM interpretation consists of eight litho-types and covers Cenozoic, Mesozoic and Paleozoic sediments down to 5 km depth. There is a remarkable agreement between the SOM based model and regional marker horizons interpolated from surrounding 2D industrial seismic data. The most interesting results include (1) distinct properties of the Jurassic (low P velocity gradients, low resistivities) interpreted as the signature of shaly clastics, and (2) a pattern within the Upper Permian Zechstein with decreased resistivities and increased P velocities within the salt depressions on the one hand, and increased resistivities and decreased P velocities in the salt pillows on the other hand. In our interpretation this pattern is related with flow of less dense salt matrix components into the pillows and remaining brittle evaporites within the depressions.

  8. Comparison of System Identification Techniques for the Hydraulic Manipulator Test Bed (HMTB)

    NASA Technical Reports Server (NTRS)

    Morris, A. Terry

    1996-01-01

    In this thesis linear, dynamic, multivariable state-space models for three joints of the ground-based Hydraulic Manipulator Test Bed (HMTB) are identified. HMTB, housed at the NASA Langley Research Center, is a ground-based version of the Dexterous Orbital Servicing System (DOSS), a representative space station manipulator. The dynamic models of the HMTB manipulator will first be estimated by applying nonparametric identification methods to determine each joint's response characteristics using various input excitations. These excitations include sum of sinusoids, pseudorandom binary sequences (PRBS), bipolar ramping pulses, and chirp input signals. Next, two different parametric system identification techniques will be applied to identify the best dynamical description of the joints. The manipulator is localized about a representative space station orbital replacement unit (ORU) task allowing the use of linear system identification methods. Comparisons, observations, and results of both parametric system identification techniques are discussed. The thesis concludes by proposing a model reference control system to aid in astronaut ground tests. This approach would allow the identified models to mimic on-orbit dynamic characteristics of the actual flight manipulator thus providing astronauts with realistic on-orbit responses to perform space station tasks in a ground-based environment.

  9. Joint inversion of multiple geophysical and petrophysical data using generalized fuzzy clustering algorithms

    NASA Astrophysics Data System (ADS)

    Sun, Jiajia; Li, Yaoguo

    2017-02-01

    Joint inversion that simultaneously inverts multiple geophysical data sets to recover a common Earth model is increasingly being applied to exploration problems. Petrophysical data can serve as an effective constraint to link different physical property models in such inversions. There are two challenges, among others, associated with the petrophysical approach to joint inversion. One is related to the multimodality of petrophysical data because there often exist more than one relationship between different physical properties in a region of study. The other challenge arises from the fact that petrophysical relationships have different characteristics and can exhibit point, linear, quadratic, or exponential forms in a crossplot. The fuzzy c-means (FCM) clustering technique is effective in tackling the first challenge and has been applied successfully. We focus on the second challenge in this paper and develop a joint inversion method based on variations of the FCM clustering technique. To account for the specific shapes of petrophysical relationships, we introduce several different fuzzy clustering algorithms that are capable of handling different shapes of petrophysical relationships. We present two synthetic and one field data examples and demonstrate that, by choosing appropriate distance measures for the clustering component in the joint inversion algorithm, the proposed joint inversion method provides an effective means of handling common petrophysical situations we encounter in practice. The jointly inverted models have both enhanced structural similarity and increased petrophysical correlation, and better represent the subsurface in the spatial domain and the parameter domain of physical properties.

  10. Prediction of In Vivo Knee Joint Kinematics Using a Combined Dual Fluoroscopy Imaging and Statistical Shape Modeling Technique

    PubMed Central

    Li, Jing-Sheng; Tsai, Tsung-Yuan; Wang, Shaobai; Li, Pingyue; Kwon, Young-Min; Freiberg, Andrew; Rubash, Harry E.; Li, Guoan

    2014-01-01

    Using computed tomography (CT) or magnetic resonance (MR) images to construct 3D knee models has been widely used in biomedical engineering research. Statistical shape modeling (SSM) method is an alternative way to provide a fast, cost-efficient, and subject-specific knee modeling technique. This study was aimed to evaluate the feasibility of using a combined dual-fluoroscopic imaging system (DFIS) and SSM method to investigate in vivo knee kinematics. Three subjects were studied during a treadmill walking. The data were compared with the kinematics obtained using a CT-based modeling technique. Geometric root-mean-square (RMS) errors between the knee models constructed using the SSM and CT-based modeling techniques were 1.16 mm and 1.40 mm for the femur and tibia, respectively. For the kinematics of the knee during the treadmill gait, the SSM model can predict the knee kinematics with RMS errors within 3.3 deg for rotation and within 2.4 mm for translation throughout the stance phase of the gait cycle compared with those obtained using the CT-based knee models. The data indicated that the combined DFIS and SSM technique could be used for quick evaluation of knee joint kinematics. PMID:25320846

  11. Repositioning the knee joint in human body FE models using a graphics-based technique.

    PubMed

    Jani, Dhaval; Chawla, Anoop; Mukherjee, Sudipto; Goyal, Rahul; Vusirikala, Nataraju; Jayaraman, Suresh

    2012-01-01

    Human body finite element models (FE-HBMs) are available in standard occupant or pedestrian postures. There is a need to have FE-HBMs in the same posture as a crash victim or to be configured in varying postures. Developing FE models for all possible positions is not practically viable. The current work aims at obtaining a posture-specific human lower extremity model by reconfiguring an existing one. A graphics-based technique was developed to reposition the lower extremity of an FE-HBM by specifying the flexion-extension angle. Elements of the model were segregated into rigid (bones) and deformable components (soft tissues). The bones were rotated about the flexion-extension axis followed by rotation about the longitudinal axis to capture the twisting of the tibia. The desired knee joint movement was thus achieved. Geometric heuristics were then used to reposition the skin. A mapping defined over the space between bones and the skin was used to regenerate the soft tissues. Mesh smoothing was then done to augment mesh quality. The developed method permits control over the kinematics of the joint and maintains the initial mesh quality of the model. For some critical areas (in the joint vicinity) where element distortion is large, mesh smoothing is done to improve mesh quality. A method to reposition the knee joint of a human body FE model was developed. Repositions of a model from 9 degrees of flexion to 90 degrees of flexion in just a few seconds without subjective interventions was demonstrated. Because the mesh quality of the repositioned model was maintained to a predefined level (typically to the level of a well-made model in the initial configuration), the model was suitable for subsequent simulations.

  12. Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment.

    PubMed

    Mahato, Niladri K; Montuelle, Stephane; Cotton, John; Williams, Susan; Thomas, James; Clark, Brian

    2016-05-18

    Single or biplanar video radiography and Roentgen stereophotogrammetry (RSA) techniques used for the assessment of in-vivo joint kinematics involves application of ionizing radiation, which is a limitation for clinical research involving human subjects. To overcome this limitation, our long-term goal is to develop a magnetic resonance imaging (MRI)-only, three dimensional (3-D) modeling technique that permits dynamic imaging of joint motion in humans. Here, we present our initial findings, as well as reliability data, for an MRI-only protocol and modeling technique. We developed a morphology-based motion-analysis technique that uses MRI of custom-built solid-body objects to animate and quantify experimental displacements between them. The technique involved four major steps. First, the imaging volume was calibrated using a custom-built grid. Second, 3-D models were segmented from axial scans of two custom-built solid-body cubes. Third, these cubes were positioned at pre-determined relative displacements (translation and rotation) in the magnetic resonance coil and scanned with a T1 and a fast contrast-enhanced pulse sequences. The digital imaging and communications in medicine (DICOM) images were then processed for animation. The fourth step involved importing these processed images into an animation software, where they were displayed as background scenes. In the same step, 3-D models of the cubes were imported into the animation software, where the user manipulated the models to match their outlines in the scene (rotoscoping) and registered the models into an anatomical joint system. Measurements of displacements obtained from two different rotoscoping sessions were tested for reliability using coefficient of variations (CV), intraclass correlation coefficients (ICC), Bland-Altman plots, and Limits of Agreement analyses. Between-session reliability was high for both the T1 and the contrast-enhanced sequences. Specifically, the average CVs for translation were 4.31 % and 5.26 % for the two pulse sequences, respectively, while the ICCs were 0.99 for both. For rotation measures, the CVs were 3.19 % and 2.44 % for the two pulse sequences with the ICCs being 0.98 and 0.97, respectively. A novel biplanar imaging approach also yielded high reliability with mean CVs of 2.66 % and 3.39 % for translation in the x- and z-planes, respectively, and ICCs of 0.97 in both planes. This work provides basic proof-of-concept for a reliable marker-less non-ionizing-radiation-based quasi-dynamic motion quantification technique that can potentially be developed into a tool for real-time joint kinematics analysis.

  13. A comparison of force sensing techniques for planetary manipulation

    NASA Technical Reports Server (NTRS)

    Helmick, Daniel; Okon, Avi; DiCicco, Matt

    2006-01-01

    Five techniques for sensing forces with a manipulator are compared analytically and experimentally. The techniques compared are: a six-axis wrist force/torque sensor, joint torque sensors, link strain gauges, motor current sensors, and flexibility modeling. The accuracy and repeatability fo each technique is quantified and compared.

  14. Development of a computational technique to measure cartilage contact area.

    PubMed

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Molecular dynamics modeling of bonding two materials by atomic scale friction stir welding

    NASA Astrophysics Data System (ADS)

    Konovalenko S., Iv.; Konovalenko, Ig. S.; Psakhie, S. G.

    2017-12-01

    Molecular dynamics model of atomic scale friction stir welding has been developed. Formation of a butt joint between two crystallites was modeled by means of rotating rigid conical tool traveling along the butt joint line. The formed joint had an intermixed atomic structure composed of atoms initially belonged to the opposite mated piece of metal. Heat removal was modeled by adding the extra viscous force to peripheral atomic layers. This technique provides the temperature control in the tool-affected zone during welding. Auxiliary vibration action was added to the rotating tool. The model provides the variation of the tool's angular velocity, amplitude, frequency and direction of the auxiliary vibration action to provide modeling different welding modes.

  16. Movement coordination patterns between the foot joints during walking.

    PubMed

    Arnold, John B; Caravaggi, Paolo; Fraysse, François; Thewlis, Dominic; Leardini, Alberto

    2017-01-01

    In 3D gait analysis, kinematics of the foot joints are usually reported via isolated time histories of joint rotations and no information is provided on the relationship between rotations at different joints. The aim of this study was to identify movement coordination patterns in the foot during walking by expanding an existing vector coding technique according to an established multi-segment foot and ankle model. A graphical representation is also described to summarise the coordination patterns of joint rotations across multiple patients. Three-dimensional multi-segment foot kinematics were recorded in 13 adults during walking. A modified vector coding technique was used to identify coordination patterns between foot joints involving calcaneus, midfoot, metatarsus and hallux segments. According to the type and direction of joints rotations, these were classified as in-phase (same direction), anti-phase (opposite directions), proximal or distal joint dominant. In early stance, 51 to 75% of walking trials showed proximal-phase coordination between foot joints comprising the calcaneus, midfoot and metatarsus. In-phase coordination was more prominent in late stance, reflecting synergy in the simultaneous inversion occurring at multiple foot joints. Conversely, a distal-phase coordination pattern was identified for sagittal plane motion of the ankle relative to the midtarsal joint, highlighting the critical role of arch shortening to locomotor function in push-off. This study has identified coordination patterns between movement of the calcaneus, midfoot, metatarsus and hallux by expanding an existing vector cording technique for assessing and classifying coordination patterns of foot joints rotations during walking. This approach provides a different perspective in the analysis of multi-segment foot kinematics, and may be used for the objective quantification of the alterations in foot joint coordination patterns due to lower limb pathologies or following injuries.

  17. Simulation of light transport in arthritic- and non-arthritic human fingers

    NASA Astrophysics Data System (ADS)

    Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.

    2014-03-01

    Rheumatoid arthritis is a disease that frequently leads to joint destruction. It has high incidence rates worldwide, and the disease significantly reduces patient's quality of life due to pain, swelling and stiffness of the affected joints. Early diagnosis is necessary to improve course of the disease, therefore sensitive and accurate diagnostic tools are required. Optical imaging techniques have capability for early diagnosis and monitoring of arthritis. As compared to conventional diagnostic techniques optical technique is a noninvasive, noncontact and fast way of collecting diagnostic information. However, a realistic model of light transport in human joints is needed for understanding and developing of such optical diagnostic tools. The aim of this study is to develop a 3D numerical model of light transport in a human finger. The model will guide development of a hyperspectral imaging (HSI) diagnostic modality for arthritis in human fingers. The implemented human finger geometry is based on anatomical data. Optical data of finger tissues are adjusted to represent either an arthritic or an unaffected finger. The geometry and optical data serve as input into a 3D Monte Carlo method, which calculate diffuse reflectance, transmittance and absorbed energy distributions. The parameters of the model are optimized based on HIS-measurements of human fingers. The presented model serves as an important tool for understanding and development of HSI as an arthritis diagnostic modality. Yet, it can be applied to other optical techniques and finger diseases.

  18. A Fast EM Algorithm for Fitting Joint Models of a Binary Response and Multiple Longitudinal Covariates Subject to Detection Limits

    PubMed Central

    Bernhardt, Paul W.; Zhang, Daowen; Wang, Huixia Judy

    2014-01-01

    Joint modeling techniques have become a popular strategy for studying the association between a response and one or more longitudinal covariates. Motivated by the GenIMS study, where it is of interest to model the event of survival using censored longitudinal biomarkers, a joint model is proposed for describing the relationship between a binary outcome and multiple longitudinal covariates subject to detection limits. A fast, approximate EM algorithm is developed that reduces the dimension of integration in the E-step of the algorithm to one, regardless of the number of random effects in the joint model. Numerical studies demonstrate that the proposed approximate EM algorithm leads to satisfactory parameter and variance estimates in situations with and without censoring on the longitudinal covariates. The approximate EM algorithm is applied to analyze the GenIMS data set. PMID:25598564

  19. MRI-based stereolithographic models of the temporomandibular joint: technical innovation.

    PubMed

    Undt, G; Wild, K; Reuther, G; Ewers, R

    2000-10-01

    A new technique of manufacturing dual-colour stereolithographic models of hard and soft tissues of the temporomandibular joint (TMJ) is presented. Sagittal T1/PD weighted magnetic resonance (MR) images of joints with and without disc displacement were obtained in the closed and open mouth positions. Individual interactive contour identification of bony structures and the articular disc followed by binary interpolation provided the data for the generation of acrylic TMJ models. Three dimensional in vivo visualization of the articular disc in relation to bony structures in the closed and open mouth positions allows a new perception of normal and pathological TMJ anatomy.

  20. Joint min-max distribution and Edwards-Anderson's order parameter of the circular 1/f-noise model

    NASA Astrophysics Data System (ADS)

    Cao, Xiangyu; Le Doussal, Pierre

    2016-05-01

    We calculate the joint min-max distribution and the Edwards-Anderson's order parameter for the circular model of 1/f-noise. Both quantities, as well as generalisations, are obtained exactly by combining the freezing-duality conjecture and Jack-polynomial techniques. Numerical checks come with significantly improved control of finite-size effects in the glassy phase, and the results convincingly validate the freezing-duality conjecture. Application to diffusive dynamics is discussed. We also provide a formula for the pre-factor ratio of the joint/marginal Carpentier-Le Doussal tail for minimum/maximum which applies to any logarithmic random energy model.

  1. Dynamic analysis of I cross beam section dissimilar plate joined by TIG welding

    NASA Astrophysics Data System (ADS)

    Sani, M. S. M.; Nazri, N. A.; Rani, M. N. Abdul; Yunus, M. A.

    2018-04-01

    In this paper, finite element (FE) joint modelling technique for prediction of dynamic properties of sheet metal jointed by tungsten inert gas (TTG) will be presented. I cross section dissimilar flat plate with different series of aluminium alloy; AA7075 and AA6061 joined by TTG are used. In order to find the most optimum set of TTG welding dissimilar plate, the finite element model with three types of joint modelling were engaged in this study; bar element (CBAR), beam element and spot weld element connector (CWELD). Experimental modal analysis (EMA) was carried out by impact hammer excitation on the dissimilar plates that welding by TTG method. Modal properties of FE model with joints were compared and validated with model testing. CWELD element was chosen to represent weld model for TTG joints due to its accurate prediction of mode shapes and contains an updating parameter for weld modelling compare to other weld modelling. Model updating was performed to improve correlation between EMA and FEA and before proceeds to updating, sensitivity analysis was done to select the most sensitive updating parameter. After perform model updating, average percentage of error of the natural frequencies for CWELD model is improved significantly.

  2. Effect of Complete Syndesmotic Disruption and Deltoid Injuries and Different Reduction Methods on Ankle Joint Contact Mechanics.

    PubMed

    LaMothe, Jeremy; Baxter, Josh R; Gilbert, Susannah; Murphy, Conor I; Karnovsky, Sydney C; Drakos, Mark C

    2017-06-01

    Syndesmotic injuries can be associated with poor patient outcomes and posttraumatic ankle arthritis, particularly in the case of malreduction. However, ankle joint contact mechanics following a syndesmotic injury and reduction remains poorly understood. The purpose of this study was to characterize the effects of a syndesmotic injury and reduction techniques on ankle joint contact mechanics in a biomechanical model. Ten cadaveric whole lower leg specimens with undisturbed proximal tibiofibular joints were prepared and tested in this study. Contact area, contact force, and peak contact pressure were measured in the ankle joint during simulated standing in the intact, injured, and 3 reduction conditions: screw fixation with a clamp, screw fixation without a clamp (thumb technique), and a suture-button construct. Differences in these ankle contact parameters were detected between conditions using repeated-measures analysis of variance. Syndesmotic disruption decreased tibial plafond contact area and force. Syndesmotic reduction did not restore ankle loading mechanics to values measured in the intact condition. Reduction with the thumb technique was able to restore significantly more joint contact area and force than the reduction clamp or suture-button construct. Syndesmotic disruption decreased joint contact area and force. Although the thumb technique performed significantly better than the reduction clamp and suture-button construct, syndesmotic reduction did not restore contact mechanics to intact levels. Decreased contact area and force with disruption imply that other structures are likely receiving more loads (eg, medial and lateral gutters), which may have clinical implications such as the development of posttraumatic arthritis.

  3. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study

    PubMed Central

    Eisenstein, Emmanuel D.; Rodriguez, Mario

    2016-01-01

    Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice. PMID:27818800

  4. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study.

    PubMed

    Eisenstein, Emmanuel D; Rodriguez, Mario; Abdelgawad, Amr A

    2016-01-01

    Introduction . Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods . We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results . Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion . Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.

  5. The validation of a human force model to predict dynamic forces resulting from multi-joint motions

    NASA Technical Reports Server (NTRS)

    Pandya, Abhilash K.; Maida, James C.; Aldridge, Ann M.; Hasson, Scott M.; Woolford, Barbara J.

    1992-01-01

    The development and validation is examined of a dynamic strength model for humans. This model is based on empirical data. The shoulder, elbow, and wrist joints were characterized in terms of maximum isolated torque, or position and velocity, in all rotational planes. This data was reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining torque as a function of position and velocity. The isolated joint torque equations were then used to compute forces resulting from a composite motion, in this case, a ratchet wrench push and pull operation. A comparison of the predicted results of the model with the actual measured values for the composite motion indicates that forces derived from a composite motion of joints (ratcheting) can be predicted from isolated joint measures. Calculated T values comparing model versus measured values for 14 subjects were well within the statistically acceptable limits and regression analysis revealed coefficient of variation between actual and measured to be within 0.72 and 0.80.

  6. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.

  7. Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.

    PubMed

    Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.

  8. Modified fluoroscopy-guided sacroiliac joint injection: a technical report.

    PubMed

    Liliang, Po-Chou; Liang, Cheng-Loong; Lu, Kang; Weng, Hui-Ching; Syu, Fei-Kai

    2014-09-01

    Sacroiliac joint (SIJ) injection can occasionally be challenging. We describe our experience in using conventional technique, and we developed an adjustment to overcome difficulties incurred. Conventional technique required superimposition of the posterior and anterior SIJ lines. If this technique failed to provide entry into the joint, fluoroscopy was slightly adjusted to obtain an oblique view. Of 50 SIJ injections, 29 (58%; 44-72%) were successfully performed using conventional technique. In another 21 procedures, 18 (85.7%; 64-99%) were subsequently completed using oblique view technique. The medial joint line, viewed from this angle, corresponded to the posterior joint line in 17 cases. The lateral joint line corresponded to the posterior joint line in one case. Oblique view technique can improve the success rate of SIJ injection. Wiley Periodicals, Inc.

  9. Joint inversion of regional and teleseismic earthquake waveforms

    NASA Astrophysics Data System (ADS)

    Baker, Mark R.; Doser, Diane I.

    1988-03-01

    A least squares joint inversion technique for regional and teleseismic waveforms is presented. The mean square error between seismograms and synthetics is minimized using true amplitudes. Matching true amplitudes in modeling requires meaningful estimates of modeling uncertainties and of seismogram signal-to-noise ratios. This also permits calculating linearized uncertainties on the solution based on accuracy and resolution. We use a priori estimates of earthquake parameters to stabilize unresolved parameters, and for comparison with a posteriori uncertainties. We verify the technique on synthetic data, and on the 1983 Borah Peak, Idaho (M = 7.3), earthquake. We demonstrate the inversion on the August 1954 Rainbow Mountain, Nevada (M = 6.8), earthquake and find parameters consistent with previous studies.

  10. A non-contact measurement technique at the micro scale

    NASA Astrophysics Data System (ADS)

    Ghosh, Santaneel

    During their production and normal use, electronic packages experience large temperature excursions, leading to high thermo-mechanical stress gradients that cause fatigue failure of the solder joints. In order to prevent premature failure and prolong the fatigue life of solder joints, there is a pressing need for the characterization of the solder, especially lead-free solder, at the micro-level (joint size). The characterization and modeling of solder behavior at the appropriate scale is a major issue. However, direct measurement techniques are not applicable to characterize the deformation response of solder joints because of their micro scale dimensions. Therefore, a non-contact measurement technique utilizing a Scanning Electron Microscope (SEM) in conjunction with Digital Image Correlation (DIC) has been developed. Validation was achieved by performing a four-point bending test in both an in-house optical system with DIC and inside the SEM. This non-contact measurement technique was then used to extract the stress-strain response of the solder. Mechanical tests were performed on solder joints that were created using the same type of solder balls used in the electronic industry and were representative of normal joint scales. The SEM-DIC technique has been proven to be applicable for the determining the stress-strain response of solder material at the micro-scale. This study resulted in a validated material characterization technique specifically designed for micro-scale material response. One of the main contributions of this study is that the method is a lot simpler and cheaper, yet highly effective, compared to the previous methods. This technique is also readily applicable to the measurement of the stress-strain response of any micro-scale specimen, such as other metals, polymers, etc. Also, the measured displacement field by obtained by DIC can be used as the base for calculating the strain field on the surface of a specimen.

  11. Computational problems in autoregressive moving average (ARMA) models

    NASA Technical Reports Server (NTRS)

    Agarwal, G. C.; Goodarzi, S. M.; Oneill, W. D.; Gottlieb, G. L.

    1981-01-01

    The choice of the sampling interval and the selection of the order of the model in time series analysis are considered. Band limited (up to 15 Hz) random torque perturbations are applied to the human ankle joint. The applied torque input, the angular rotation output, and the electromyographic activity using surface electrodes from the extensor and flexor muscles of the ankle joint are recorded. Autoregressive moving average models are developed. A parameter constraining technique is applied to develop more reliable models. The asymptotic behavior of the system must be taken into account during parameter optimization to develop predictive models.

  12. Hyperspectral imaging for detection of arthritis: feasibility and prospects

    NASA Astrophysics Data System (ADS)

    Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.

    2015-09-01

    Rheumatoid arthritis (RA) is a disease that frequently leads to joint destruction. It has a high incidence rate worldwide, and the disease significantly reduces patients' quality of life. Detecting and treating inflammatory arthritis before structural damage to the joint has occurred is known to be essential for preventing patient disability and pain. Existing diagnostic technologies are expensive, time consuming, and require trained personnel to collect and interpret data. Optical techniques might be a fast, noninvasive alternative. Hyperspectral imaging (HSI) is a noncontact optical technique which provides both spectral and spatial information in one measurement. In this study, the feasibility of HSI in arthritis diagnostics was explored by numerical simulations and optimal imaging parameters were identified. Hyperspectral reflectance and transmission images of RA and normal human joint models were simulated using the Monte Carlo method. The spectral range was 600 to 1100 nm. Characteristic spatial patterns for RA joints and two spectral windows with transmission were identified. The study demonstrated that transmittance images of human joints could be used as one parameter for discrimination between arthritic and unaffected joints. The presented work shows that HSI is a promising imaging modality for the diagnostics and follow-up monitoring of arthritis in small joints.

  13. Analysis of the Lenticular Jointed MARSIS Antenna Deployment

    NASA Technical Reports Server (NTRS)

    Mobrem, Mehran; Adams, Douglas S.

    2006-01-01

    This paper summarizes important milestones in a yearlong comprehensive effort which culminated in successful deployments of the MARSIS antenna booms in May and June of 2005. Experimentally measured straight section and hinge properties are incorporated into specialized modeling techniques that are used to simulate the boom lenticular joints. System level models are exercised to understand the boom deployment dynamics and spacecraft level implications. Discussion includes a comparison of ADAMS simulation results to measured flight data taken during the three boom deployments. Important parameters that govern lenticular joint behavior are outlined and a short summary of lessons learned and recommendations is included to better understand future applications of this technology.

  14. Quantifying in vivo laxity in the anterior cruciate ligament and individual knee joint structures.

    PubMed

    Westover, L M; Sinaei, N; Küpper, J C; Ronsky, J L

    2016-11-01

    A custom knee loading apparatus (KLA), when used in conjunction with magnetic resonance imaging, enables in vivo measurement of the gross anterior laxity of the knee joint. A numerical model was applied to the KLA to understand the contribution of the individual joint structures and to estimate the stiffness of the anterior-cruciate ligament (ACL). The model was evaluated with a cadaveric study using an in situ knee loading apparatus and an ElectroForce test system. A constrained optimization solution technique was able to predict the restraining forces within the soft-tissue structures and joint contact. The numerical model presented here allowed in vivo prediction of the material stiffness parameters of the ACL in response to applied anterior loading. Promising results were obtained for in vivo load sharing within the structures. The numerical model overestimated the ACL forces by 27.61-92.71%. This study presents a novel approach to estimate ligament stiffness and provides the basis to develop a robust and accurate measure of in vivo knee joint laxity.

  15. Correlative analysis of hard and soft x ray observations of solar flares

    NASA Technical Reports Server (NTRS)

    Zarro, Dominic M.

    1994-01-01

    We have developed a promising new technique for jointly analyzing BATSE hard X-ray observations of solar flares with simultaneous soft X-ray observations. The technique is based upon a model in which electric currents and associated electric fields are responsible for the respective heating and particle acceleration that occur in solar flares. A useful by-product of this technique is the strength and evolution of the coronal electric field. The latter permits one to derive important flare parameters such as the current density, the number of current filaments composing the loop, and ultimately the hard X-ray spectrum produced by the runaway electrons. We are continuing to explore the technique by applying it to additional flares for which we have joint BATSE/Yohkoh observations. A central assumption of our analysis is the constant of proportionality alpha relating the hard X-ray flux above 50 keV and the rate of electron acceleration. For a thick-target model of hard X-ray production, it can be shown that cv is in fact related to the spectral index and low-energy cutoff of precipitating electrons. The next step in our analysis is to place observational constraints on the latter parameters using the joint BATSE/Yohkoh data.

  16. A Three Dimensional Model of the Feline Hindlimb

    PubMed Central

    Burkholder, Thomas J.; Richard Nichols, T.

    2007-01-01

    This paper describes a three dimensional musculoskeletal model of the feline hindlimb based on digitized musculoskeletal anatomy. The model consists of seven degrees of freedom: three at the hip and two each at the knee and ankle. Lines of action and via points for 32 major muscles of the limb are described. Interspecimen variability of muscle paths was surprisingly low: most via points displayed a scatter of only a few millimeters. Joint axes identified by mechanical techniques as non-coincident and non-orthogonal were further honed to yield moment arms consistent with previous reports. Interspecimen variability in joint axes was greater than that of muscle paths and highlights the importance of joint axes in kinematic models. The contribution of specific muscles to the direction of endpoint force generation is discussed. PMID:15164372

  17. Modeling the Influence of Stitching on Delamination Growth in Stitched Warp-Knit Composite Lap Joints

    NASA Technical Reports Server (NTRS)

    Glaessgen, E. H.; Raju, I. S.; Poe, C. C., Jr.

    1999-01-01

    The effect of stitches on the failure of a single lap joint configuration was determined in a combined experimental and analytical study. The experimental study was conducted to determine debond growth under static monotonic loading. The stitches were shown to delay the initiation of the debond and provide load transfer beyond the load necessary to completely debond the stitched lap joint. The strain energy release rates at the debond front were calculated using a finite element-based technique. Models of the unstitched configuration showed significant values of modes I and II across the width of the joint and showed that mode III is zero at the centerline but increases near the free edge. Models of the stitched configuration showed that the stitches effectively reduced mode I to zero, but had less of an effect on modes II and III.

  18. Exploring novel objective functions for simulating muscle coactivation in the neck.

    PubMed

    Mortensen, J; Trkov, M; Merryweather, A

    2018-04-11

    Musculoskeletal modeling allows for analysis of individual muscles in various situations. However, current techniques to realistically simulate muscle response when significant amounts of intentional coactivation is required are inadequate. This would include stiffening the neck or spine through muscle coactivation in preparation for perturbations or impacts. Muscle coactivation has been modeled previously in the neck and spine using optimization techniques that seek to maximize the joint stiffness by maximizing total muscle activation or muscle force. These approaches have not sought to replicate human response, but rather to explore the possible effects of active muscle. Coactivation remains a challenging feature to include in musculoskeletal models, and may be improved by extracting optimization objective functions from experimental data. However, the components of such an objective function must be known before fitting to experimental data. This study explores the effect of components in several objective functions, in order to recommend components to be used for fitting to experimental data. Four novel approaches to modeling coactivation through optimization techniques are presented, two of which produce greater levels of stiffness than previous techniques. Simulations were performed using OpenSim and MATLAB cooperatively. Results show that maximizing the moment generated by a particular muscle appears analogous to maximizing joint stiffness. The approach of optimizing for maximum moment generated by individual muscles may be a good candidate for developing objective functions that accurately simulate muscle coactivation in complex joints. This new approach will be the focus of future studies with human subjects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Animal models of cartilage repair

    PubMed Central

    Cook, J. L.; Hung, C. T.; Kuroki, K.; Stoker, A. M.; Cook, C. R.; Pfeiffer, F. M.; Sherman, S. L.; Stannard, J. P.

    2014-01-01

    Cartilage repair in terms of replacement, or regeneration of damaged or diseased articular cartilage with functional tissue, is the ‘holy grail’ of joint surgery. A wide spectrum of strategies for cartilage repair currently exists and several of these techniques have been reported to be associated with successful clinical outcomes for appropriately selected indications. However, based on respective advantages, disadvantages, and limitations, no single strategy, or even combination of strategies, provides surgeons with viable options for attaining successful long-term outcomes in the majority of patients. As such, development of novel techniques and optimisation of current techniques need to be, and are, the focus of a great deal of research from the basic science level to clinical trials. Translational research that bridges scientific discoveries to clinical application involves the use of animal models in order to assess safety and efficacy for regulatory approval for human use. This review article provides an overview of animal models for cartilage repair. Cite this article: Bone Joint Res 2014;4:89–94. PMID:24695750

  20. Large animal models in experimental knee sports surgery: focus on clinical translation.

    PubMed

    Madry, Henning; Ochi, Mitsuo; Cucchiarini, Magali; Pape, Dietrich; Seil, Romain

    2015-12-01

    Large animal models play a crucial role in sports surgery of the knee, as they are critical for the exploration of new experimental strategies and the clinical translation of novel techniques. The purpose of this contribution is to provide critical aspects of relevant animal models in this field, with a focus on paediatric anterior cruciate ligament (ACL) reconstruction, high tibial osteotomy, and articular cartilage repair. Although there is no single large animal model strictly replicating the human knee joint, the sheep stifle joint shares strong similarities. Studies in large animal models of paediatric ACL reconstruction identified specific risk factors associated with the different surgical techniques. The sheep model of high tibial osteotomy is a powerful new tool to advance the understanding of the effect of axial alignment on the lower extremity on specific issues of the knee joint. Large animal models of both focal chondral and osteochondral defects and of osteoarthritis have brought new findings about the mechanisms of cartilage repair and treatment options. The clinical application of a magnetic device for targeted cell delivery serves as a suitable example of how data from such animal models are directly translated into in clinical cartilage repair. As novel insights from studies in these translational models will advance the basic science, close cooperation in this important field of clinical translation will improve current reconstructive surgical options and open novel avenues for regenerative therapies of musculoskeletal disorders.

  1. Climate Change Impact Assessment in Pacific North West Using Copula based Coupling of Temperature and Precipitation variables

    NASA Astrophysics Data System (ADS)

    Qin, Y.; Rana, A.; Moradkhani, H.

    2014-12-01

    The multi downscaled-scenario products allow us to better assess the uncertainty of the changes/variations of precipitation and temperature in the current and future periods. Joint Probability distribution functions (PDFs), of both the climatic variables, might help better understand the interdependence of the two, and thus in-turn help in accessing the future with confidence. Using the joint distribution of temperature and precipitation is also of significant importance in hydrological applications and climate change studies. In the present study, we have used multi-modelled statistically downscaled-scenario ensemble of precipitation and temperature variables using 2 different statistically downscaled climate dataset. The datasets used are, 10 Global Climate Models (GCMs) downscaled products from CMIP5 daily dataset, namely, those from the Bias Correction and Spatial Downscaling (BCSD) technique generated at Portland State University and from the Multivariate Adaptive Constructed Analogs (MACA) technique, generated at University of Idaho, leading to 2 ensemble time series from 20 GCM products. Thereafter the ensemble PDFs of both precipitation and temperature is evaluated for summer, winter, and yearly periods for all the 10 sub-basins across Columbia River Basin (CRB). Eventually, Copula is applied to establish the joint distribution of two variables enabling users to model the joint behavior of the variables with any level of correlation and dependency. Moreover, the probabilistic distribution helps remove the limitations on marginal distributions of variables in question. The joint distribution is then used to estimate the change trends of the joint precipitation and temperature in the current and future, along with estimation of the probabilities of the given change. Results have indicated towards varied change trends of the joint distribution of, summer, winter, and yearly time scale, respectively in all 10 sub-basins. Probabilities of changes, as estimated by the joint precipitation and temperature, will provide useful information/insights for hydrological and climate change predictions.

  2. Modal analysis and control of flexible manipulator arms. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Neto, O. M.

    1974-01-01

    The possibility of modeling and controlling flexible manipulator arms was examined. A modal approach was used for obtaining the mathematical model and control techniques. The arm model was represented mathematically by a state space description defined in terms of joint angles and mode amplitudes obtained from truncation on the distributed systems, and included the motion of a two link two joint arm. Three basic techniques were used for controlling the system: pole allocation with gains obtained from the rigid system with interjoint feedbacks, Simon-Mitter algorithm for pole allocation, and sensitivity analysis with respect to parameter variations. An improvement in arm bandwidth was obtained. Optimization of some geometric parameters was undertaken to maximize bandwidth for various payload sizes and programmed tasks. The controlled system is examined under constant gains and using the nonlinear model for simulations following a time varying state trajectory.

  3. Modelling tendon excursions and moment arms of the finger flexors: anatomic fidelity versus function.

    PubMed

    Kociolek, Aaron M; Keir, Peter J

    2011-07-07

    A detailed musculoskeletal model of the human hand is needed to investigate the pathomechanics of tendon disorders and carpal tunnel syndrome. The purpose of this study was to develop a biomechanical model with realistic flexor tendon excursions and moment arms. An existing upper extremity model served as a starting point, which included programmed movement of the index finger. Movement capabilities were added for the other fingers. Metacarpophalangeal articulations were modelled as universal joints to simulate flexion/extension and abduction/adduction while interphalangeal articulations used hinges to represent flexion. Flexor tendon paths were modelled using two approaches. The first method constrained tendons with control points, representing annular pulleys. The second technique used wrap objects at the joints as tendon constraints. Both control point and joint wrap models were iteratively adjusted to coincide with tendon excursions and moment arms from a anthropometric regression model using inputs for a 50th percentile male. Tendon excursions from the joint wrap method best matched the regression model even though anatomic features of the tendon paths were not preserved (absolute differences: mean<0.33 mm, peak<0.74 mm). The joint wrap model also produced similar moment arms to the regression (absolute differences: mean<0.63 mm, peak<1.58 mm). When a scaling algorithm was used to test anthropometrics, the scaled joint wrap models better matched the regression than the scaled control point models. Detailed patient-specific anatomical data will improve model outcomes for clinical use; however, population studies may benefit from simplified geometry, especially with anthropometric scaling. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Joint Utility of Event-Dependent and Environmental Crime Analysis Techniques for Violent Crime Forecasting

    ERIC Educational Resources Information Center

    Caplan, Joel M.; Kennedy, Leslie W.; Piza, Eric L.

    2013-01-01

    Violent crime incidents occurring in Irvington, New Jersey, in 2007 and 2008 are used to assess the joint analytical capabilities of point pattern analysis, hotspot mapping, near-repeat analysis, and risk terrain modeling. One approach to crime analysis suggests that the best way to predict future crime occurrence is to use past behavior, such as…

  5. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network.

    PubMed

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Facchini, Francesco; Mummolo, Giovanni; Ludovico, Antonio Domenico

    2016-11-10

    A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW) process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable) and the mechanical properties (output responses) of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls). The simulation model was based on the adoption of the Artificial Neural Networks (ANNs) characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration.

  6. Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model

    PubMed Central

    Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672

  7. The Gaussian atmospheric transport model and its sensitivity to the joint frequency distribution and parametric variability.

    PubMed

    Hamby, D M

    2002-01-01

    Reconstructed meteorological data are often used in some form of long-term wind trajectory models for estimating the historical impacts of atmospheric emissions. Meteorological data for the straight-line Gaussian plume model are put into a joint frequency distribution, a three-dimensional array describing atmospheric wind direction, speed, and stability. Methods using the Gaussian model and joint frequency distribution inputs provide reasonable estimates of downwind concentration and have been shown to be accurate to within a factor of four. We have used multiple joint frequency distributions and probabilistic techniques to assess the Gaussian plume model and determine concentration-estimate uncertainty and model sensitivity. We examine the straight-line Gaussian model while calculating both sector-averaged and annual-averaged relative concentrations at various downwind distances. The sector-average concentration model was found to be most sensitive to wind speed, followed by horizontal dispersion (sigmaZ), the importance of which increases as stability increases. The Gaussian model is not sensitive to stack height uncertainty. Precision of the frequency data appears to be most important to meteorological inputs when calculations are made for near-field receptors, increasing as stack height increases.

  8. Structural health management of aerospace hotspots under fatigue loading

    NASA Astrophysics Data System (ADS)

    Soni, Sunilkumar

    Sustainability and life-cycle assessments of aerospace systems, such as aircraft structures and propulsion systems, represent growing challenges in engineering. Hence, there has been an increasing demand in using structural health monitoring (SHM) techniques for continuous monitoring of these systems in an effort to improve safety and reduce maintenance costs. The current research is part of an ongoing multidisciplinary effort to develop a robust SHM framework resulting in improved models for damage-state awareness and life prediction, and enhancing capability of future aircraft systems. Lug joints, a typical structural hotspot, were chosen as the test article for the current study. The thesis focuses on integrated SHM techniques for damage detection and characterization in lug joints. Piezoelectric wafer sensors (PZTs) are used to generate guided Lamb waves as they can be easily used for onboard applications. Sensor placement in certain regions of a structural component is not feasible due to the inaccessibility of the area to be monitored. Therefore, a virtual sensing concept is introduced to acquire sensor data from finite element (FE) models. A full three dimensional FE analysis of lug joints with piezoelectric transducers, accounting for piezoelectrical-mechanical coupling, was performed in Abaqus and the sensor signals were simulated. These modeled sensors are called virtual sensors. A combination of real data from PZTs and virtual sensing data from FE analysis is used to monitor and detect fatigue damage in aluminum lug joints. Experiments were conducted on lug joints under fatigue loads and sensor signals collected were used to validate the simulated sensor response. An optimal sensor placement methodology for lug joints is developed based on a detection theory framework to maximize the detection rate and minimize the false alarm rate. The placement technique is such that the sensor features can be directly correlated to damage. The technique accounts for a number of factors, such as actuation frequency and strength, minimum damage size, damage detection scheme, material damping, signal to noise ratio and sensing radius. Advanced information processing methodologies are discussed for damage diagnosis. A new, instantaneous approach for damage detection, localization and quantification is proposed for applications to practical problems associated with changes in reference states under different environmental and operational conditions. Such an approach improves feature extraction for state awareness, resulting in robust life prediction capabilities.

  9. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    PubMed

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  10. Pressure application measurement (PAM): a novel behavioural technique for measuring hypersensitivity in a rat model of joint pain.

    PubMed

    Barton, Nicola J; Strickland, Iain T; Bond, Susan M; Brash, Harry M; Bate, Simon T; Wilson, Alex W; Chessell, Iain P; Reeve, Alison J; McQueen, Daniel S

    2007-06-15

    Chronic joint pain affects physical well being and can lead to severe psychological and social problems, therefore successful long-term management is highly sought-after. No current behavioural measures of pain used in pre-clinical models mimic the clinical dolorimeter, which provides an objective measure of joint hypersensitivity. In this study we aim to use a novel behavioural readout alongside an established measure to mimic the multifactorial measurements taken in the clinic. Using the pressure application measurement (PAM) device a gradually increasing squeeze was applied across the knee joint of rats until the animal gave an indication of pain or discomfort. PAM and the incapacitance tester were used to detect joint hypersensitivity in a well-established rodent model of adjuvant-induced arthritis. Subsequently, the analgesic effects of prednisolone (1, 3 or 10 mg kg(-1)), morphine (3 mg kg(-1)) and celecoxib (15 mg kg(-1)) were assessed. Both PAM and the incapacitance tester detected a reversal of hypersensitivity 1h post-drug administration. Furthermore, the two readouts were highly correlated, and power analysis indicated that PAM was highly reproducible. In conclusion, PAM provides a novel, accurate behavioural tool for detecting a primary mechanical hypersensitivity in a rat model of chronic inflammatory joint pain.

  11. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    NASA Astrophysics Data System (ADS)

    Frear, D. R.; Burchett, S. N.; Rashid, M. M.

    The thermomechanical fatigue failure of solder joints is increasingly becoming an important reliability issue. We present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. The single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.

  12. Global-Local Finite Element Analysis of Bonded Single-Lap Joints

    NASA Technical Reports Server (NTRS)

    Kilic, Bahattin; Madenci, Erdogan; Ambur, Damodar R.

    2004-01-01

    Adhesively bonded lap joints involve dissimilar material junctions and sharp changes in geometry, possibly leading to premature failure. Although the finite element method is well suited to model the bonded lap joints, traditional finite elements are incapable of correctly resolving the stress state at junctions of dissimilar materials because of the unbounded nature of the stresses. In order to facilitate the use of bonded lap joints in future structures, this study presents a finite element technique utilizing a global (special) element coupled with traditional elements. The global element includes the singular behavior at the junction of dissimilar materials with or without traction-free surfaces.

  13. Debonding of Stitched Composite Joints: Testing and Analysis

    NASA Technical Reports Server (NTRS)

    Glaessgen, E. H.; Raju, I. S.; Poe, C. C., Jr.

    1999-01-01

    The effect of stitches on the failure of a single lap joint configuration was determined in a combined experimental and analytical study. The experimental study was conducted to determine debond growth under static monotonic loading. The stitches were shown to delay the initiation ofthe debond and provide load transfer beyond the load necessary to completely debond the stitched lap joint. The strain energy release rates at the debond front were calculated using a finite element-based technique. Models of the unstitched configuration showed significant values of modes I and II across the width of the joint and showed that mode III is zero at the centerline but increases near the free edge. Models of the stitched configuration showed that the stitches effectively reduced mode I to zero, but had less of an effect on modes II and III.

  14. Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography.

    PubMed

    Kang, Kyoung-Tak; Kim, Sung-Hwan; Son, Juhyun; Lee, Young Han; Koh, Yong-Gon

    2017-01-01

    Computational models have been identified as efficient techniques in the clinical decision-making process. However, computational model was validated using published data in most previous studies, and the kinematic validation of such models still remains a challenge. Recently, studies using medical imaging have provided a more accurate visualization of knee joint kinematics. The purpose of the present study was to perform kinematic validation for the subject-specific computational knee joint model by comparison with subject's medical imaging under identical laxity condition. The laxity test was applied to the anterior-posterior drawer under 90° flexion and the varus-valgus under 20° flexion with a series of stress radiographs, a Telos device, and computed tomography. The loading condition in the computational subject-specific knee joint model was identical to the laxity test condition in the medical image. Our computational model showed knee laxity kinematic trends that were consistent with the computed tomography images, except for negligible differences because of the indirect application of the subject's in vivo material properties. Medical imaging based on computed tomography with the laxity test allowed us to measure not only the precise translation but also the rotation of the knee joint. This methodology will be beneficial in the validation of laxity tests for subject- or patient-specific computational models.

  15. [Example of product development by industry and research solidarity].

    PubMed

    Seki, Masayoshi

    2014-01-01

    When the industrial firms develop the product, the research result from research institutions is used or to reflect the ideas from users on the developed product would be significant in order to improve the product. To state the software product which developed jointly as an example to describe the adopted development technique and its result, and to consider the modality of the industry solidarity seen from the company side and joint development. The software development methods have the merit and demerit and necessary to choose the optimal development technique by the system which develops. We have been jointly developed the dose distribution browsing software. As the software development method, we adopted the prototype model. In order to display the dose distribution information, it is necessary to load four objects which are CT-Image, Structure Set, RT-Plan, and RT-Dose, are displayed in a composite manner. The prototype model which is the development technique was adopted by this joint development was optimal especially to develop the dose distribution browsing software. In a prototype model, since the detail design was created based on the program source code after the program was finally completed, there was merit on the period shortening of document written and consist in design and implementation. This software eventually opened to the public as an open source. Based on this developed prototype software, the release version of the dose distribution browsing software was developed. Developing this type of novelty software, it normally takes two to three years, but since the joint development was adopted, it shortens the development period to one year. Shortening the development period was able to hold down to the minimum development cost for a company and thus, this will be reflected to the product price. The specialists make requests on the product from user's point of view are important, but increase in specialists as professionals for product development will increase the expectations to develop a product to meet the users demand.

  16. Pressure relief and other joint rehabilitation techniques

    DOT National Transportation Integrated Search

    1987-02-01

    A study of four major concrete pavement joint rehabilitation techniques has been conducted, including: pressure relief joints, full-depth repairs, partial-depth repairs and joint resealing. The products of this research include the following for each...

  17. Pressure relief and other joint rehabilitation techniques : appendices

    DOT National Transportation Integrated Search

    1987-02-01

    Appendices of a study of four major concrete pavement joint rehabilitation techniques has been conducted, including: pressure relief joints, full-depth repairs, partial-depth repairs and joint resealing. The products of this research include the foll...

  18. Feature-extracted joint transform correlation.

    PubMed

    Alam, M S

    1995-12-10

    A new technique for real-time optical character recognition that uses a joint transform correlator is proposed. This technique employs feature-extracted patterns for the reference image to detect a wide range of characters in one step. The proposed technique significantly enhances the processing speed when compared with the presently available joint transform correlator architectures and shows feasibility for multichannel joint transform correlation.

  19. Multi-Scale Computational Modeling of Ni-Base Superalloy Brazed Joints for Gas Turbine Applications

    NASA Astrophysics Data System (ADS)

    Riggs, Bryan

    Brazed joints are commonly used in the manufacture and repair of aerospace components including high temperature gas turbine components made of Ni-base superalloys. For such critical applications, it is becoming increasingly important to account for the mechanical strength and reliability of the brazed joint. However, material properties of brazed joints are not readily available and methods for evaluating joint strength such as those listed in AWS C3.2 have inherent challenges compared with testing bulk materials. In addition, joint strength can be strongly influenced by the degree of interaction between the filler metal (FM) and the base metal (BM), the joint design, and presence of flaws or defects. As a result, there is interest in the development of a multi-scale computational model to predict the overall mechanical behavior and fitness-for-service of brazed joints. Therefore, the aim of this investigation was to generate data and methodology to support such a model for Ni-base superalloy brazed joints with conventional Ni-Cr-B based FMs. Based on a review of the technical literature a multi-scale modeling approach was proposed to predict the overall performance of brazed joints by relating mechanical properties to the brazed joint microstructure. This approach incorporates metallurgical characterization, thermodynamic/kinetic simulations, mechanical testing, fracture mechanics and finite element analysis (FEA) modeling to estimate joint properties based on the initial BM/FM composition and brazing process parameters. Experimental work was carried out in each of these areas to validate the multi-scale approach and develop improved techniques for quantifying brazed joint properties. Two Ni-base superalloys often used in gas turbine applications, Inconel 718 and CMSX-4, were selected for study and vacuum furnace brazed using two common FMs, BNi-2 and BNi-9. Metallurgical characterization of these brazed joints showed two primary microstructural regions; a soft, ductile a-Ni phase that formed at the joint interface and a hard, brittle multi-phase centerline eutectic. CrB and Ni3B type borides were identified in the eutectic region via electron probe micro-analysis, and a boron diffusion gradient was observed in the BM adjacent to the joint. The volume fraction of centerline eutectic was found to be highly dependent on the extent of the boron diffusion that occurred during brazing and therefore a function of the primary process parameters; hold time, temperature, FM/BM composition, and joint gap. Thermo-Calc(TM) and DICTRA(TM) simulations were used to model the BM dissolution, isothermal solidification and phase transformations that occurred during brazing to predict the final joint microstructure based on these process parameters. Good agreement was found between experimental and simulated joint microstructures at various joint gaps demonstrating the application of these simulations for brazed joints. However, thermodynamic/kinetic databases available for brazing FMs were limited. A variety of mechanical testing was performed to determine the mechanical properties of CMSX-4/BNi-2 and IN718/BNi-2 brazed joints including small-scale tensile tests, standard-size butt joints and lap shear tests. Small-scale tensile testing provided a novel method for studying microstructure-property relationships in brazed joints and indicated that both joint strength and ductility decrease significantly with an increase in the volume fraction of centerline eutectic. In-situ observations during small-scale testing also showed strain localization and crack initiation occurs around the hard, eutectic phases in the joint microstructure during loading. The average tensile strength for standard-size IN718/BNi-2 butt joints containing a low volume fraction of centerline eutectic was found to be 152.8 ksi approximately 90% of the BM yield strength (˜170 ksi). The average lap shear FM stress was found to decrease from 70 to 20 ksi for IN718/BNi-2 joints and from 50 to 15 ksi for CMSX-4/BNi-2 as the overlap was increased from 1T to 5T due to non-uniform stress/strain distribution across the joint. Digital image correlation techniques and FEA models of the lap shear brazed joints were developed to assess the strain distributions across the overlap. Results were used to validate the use of damage zone models for predicting the load carrying capacity of lap shear brazed joints and suggest that the damage zone is independent of the overlap length. To account for the presence of flaws and defects in fitness-for-service assessments of brazed joints determination of the average fracture toughness (KIC) is necessary. Currently no standard exists to measure the KIC for brazed joints, so three test methods were evaluated in this investigation on IN718/BNi-2 brazed joints. The compact tension and double cantilever beam test methods were found to give the most conservative KIC values of 16.42 and 14.42 ksivin respectively. Linear-elastic FEA models of the test specimens were used to validate the calculated KIC values. Similar to joint strength the fracture toughness appeared to be strongly influenced by the volume fraction of centerline eutectic phases. (Abstract shortened by ProQuest.).

  20. A simple approach to the joint inversion of seismic body and surface waves applied to the southwest U.S.

    NASA Astrophysics Data System (ADS)

    West, Michael; Gao, Wei; Grand, Stephen

    2004-08-01

    Body and surface wave tomography have complementary strengths when applied to regional-scale studies of the upper mantle. We present a straight-forward technique for their joint inversion which hinges on treating surface waves as horizontally-propagating rays with deep sensitivity kernels. This formulation allows surface wave phase or group measurements to be integrated directly into existing body wave tomography inversions with modest effort. We apply the joint inversion to a synthetic case and to data from the RISTRA project in the southwest U.S. The data variance reductions demonstrate that the joint inversion produces a better fit to the combined dataset, not merely a compromise. For large arrays, this method offers an improvement over augmenting body wave tomography with a one-dimensional model. The joint inversion combines the absolute velocity of a surface wave model with the high resolution afforded by body waves-both qualities that are required to understand regional-scale mantle phenomena.

  1. Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests.

    PubMed

    Lee, Chian-Her; Hsu, Ching-Chi; Huang, Po-Yuang

    2017-08-01

    The pelvis is one of the most stressed areas of the human musculoskeletal system due to the transfer of truncal loads to the lower extremities. Sacroiliac joint injury may lead to abnormal joint mechanics and an unstable pelvis. Various fixation techniques have been evaluated and discussed. However, it may be difficult to investigate each technique due to variations in bone quality, bone anatomy, fracture pattern, and fixation location. Additionally, the finite element method is one useful technology that avoids these variations. Unfortunately, most previous studies neglected the effects of the lumbar spine and femurs when they investigated the biomechanics of pelvises. Thus, the aim of this study was to investigate the biomechanical performance of intact, injured, and treated pelvises using numerical and experimental approaches. Three-dimensional finite element models of the spine-pelvis-femur complex with and without muscles and ligaments were developed. The intact pelvis, the pelvis with sacroiliac joint injury, and three types of pelvic fixation techniques were analyzed. Concurrently, biomechanical tests were conducted to validate the numerical outcomes using artificial pelvises. Posterior iliosacral screw fixation showed relatively better fixation stability and lower risks of implant failure and pelvic breakage than sacral bar fixation and a locking compression plate fixation. The present study can help surgeons and engineers understand the biomechanics of intact, injured, and treated pelvises. Both the simulation technique and the experimental setup can be applied to investigate different pelvic injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Why do spinal manipulation techniques take the form they do? Towards a general model of spinal manipulation.

    PubMed

    Evans, David W

    2010-06-01

    For centuries, techniques used to manipulate joints in the spine have been passed down from one generation of manipulators to the next. Today, spinal manipulation is in the curious position that positive clinical effects have now been demonstrated, yet the theoretical base underpinning every aspect of its use is still underdeveloped. An important question is posed in this masterclass: why do spinal manipulation techniques take the form they do? From the available literature, two factors appear to provide an answer: 1. Action of a force upon vertebrae. Any 'direct' spinal manipulation technique requires that the patient be orientated in such a way that force is applied perpendicular to the overlying skin surface so as to act upon the vertebrae beneath. If the vertebral motion produced by 'directly' applied force is insufficient to produce the desired effect (e.g. cavitation), then force must be applied 'indirectly', often through remote body segments such as the head, thorax, abdomen, pelvis, and extremities. 2. Spinal segment morphology. A new hypothesis is presented. Spinal manipulation techniques exploit the morphology of vertebrae by inducing rotation at a spinal segment, about an axis that is always parallel to the articular surfaces of the constituent zygapophysial joints. In doing so, the articular surfaces of one zygapophysial joint appose to the point of contact, resulting in migration of the axis of rotation towards these contacting surfaces, and in turn this facilitates gapping of the other (target) zygapophysial joint. Other variations in the form of spinal manipulation techniques are likely to depend upon the personal style and individual choices of the practitioner.

  3. Joint inversion of apparent resistivity and seismic surface and body wave data

    NASA Astrophysics Data System (ADS)

    Garofalo, Flora; Sauvin, Guillaume; Valentina Socco, Laura; Lecomte, Isabelle

    2013-04-01

    A novel inversion algorithm has been implemented to jointly invert apparent resistivity curves from vertical electric soundings, surface wave dispersion curves, and P-wave travel times. The algorithm works in the case of laterally varying layered sites. Surface wave dispersion curves and P-wave travel times can be extracted from the same seismic dataset and apparent resistivity curves can be obtained from continuous vertical electric sounding acquisition. The inversion scheme is based on a series of local 1D layered models whose unknown parameters are thickness h, S-wave velocity Vs, P-wave velocity Vp, and Resistivity R of each layer. 1D models are linked to surface-wave dispersion curves and apparent resistivity curves through classical 1D forward modelling, while a 2D model is created by interpolating the 1D models and is linked to refracted P-wave hodograms. A priori information can be included in the inversion and a spatial regularization is introduced as a set of constraints between model parameters of adjacent models and layers. Both a priori information and regularization are weighted by covariance matrixes. We show the comparison of individual inversions and joint inversion for a synthetic dataset that presents smooth lateral variations. Performing individual inversions, the poor sensitivity to some model parameters leads to estimation errors up to 62.5 %, whereas for joint inversion the cooperation of different techniques reduces most of the model estimation errors below 5% with few exceptions up to 39 %, with an overall improvement. Even though the final model retrieved by joint inversion is internally consistent and more reliable, the analysis of the results evidences unacceptable values of Vp/Vs ratio for some layers, thus providing negative Poisson's ratio values. To further improve the inversion performances, an additional constraint is added imposing Poisson's ratio in the range 0-0.5. The final results are globally improved by the introduction of this constraint further reducing the maximum error to 30 %. The same test was performed on field data acquired in a landslide-prone area close by the town of Hvittingfoss, Norway. Seismic data were recorded on two 160-m long profiles in roll-along mode using a 5-kg sledgehammer as source and 24 4.5-Hz vertical geophones with 4-m separation. First-arrival travel times were picked at every shot locations and surface wave dispersion curves extracted at 8 locations for each profile. 2D resistivity measurements were carried out on the same profiles using Gradient and Dipole-Dipole arrays with 2-m electrode spacing. The apparent resistivity curves were extracted at the same location as for the dispersion curves. The data were subsequently jointly inverted and the resulting model compared to individual inversions. Although models from both, individual and joint inversions are consistent, the estimation error is smaller for joint inversion, and more especially for first-arrival travel times. The joint inversion exploits different sensitivities of the methods to model parameters and therefore mitigates solution nonuniqueness and the effects of intrinsic limitations of the different techniques. Moreover, it produces an internally consistent multi-parametric final model that can be profitably interpreted to provide a better understanding of subsurface properties.

  4. Robust tuning of robot control systems

    NASA Technical Reports Server (NTRS)

    Minis, I.; Uebel, M.

    1992-01-01

    The computed torque control problem is examined for a robot arm with flexible, geared, joint drive systems which are typical in many industrial robots. The standard computed torque algorithm is not directly applicable to this class of manipulators because of the dynamics introduced by the joint drive system. The proposed approach to computed torque control combines a computed torque algorithm with torque controller at each joint. Three such control schemes are proposed. The first scheme uses the joint torque control system currently implemented on the robot arm and a novel form of the computed torque algorithm. The other two use the standard computed torque algorithm and a novel model following torque control system based on model following techniques. Standard tasks and performance indices are used to evaluate the performance of the controllers. Both numerical simulations and experiments are used in evaluation. The study shows that all three proposed systems lead to improved tracking performance over a conventional PD controller.

  5. Prediction of the Vickers Microhardness and Ultimate Tensile Strength of AA5754 H111 Friction Stir Welding Butt Joints Using Artificial Neural Network

    PubMed Central

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Facchini, Francesco; Mummolo, Giovanni; Ludovico, Antonio Domenico

    2016-01-01

    A simulation model was developed for the monitoring, controlling and optimization of the Friction Stir Welding (FSW) process. This approach, using the FSW technique, allows identifying the correlation between the process parameters (input variable) and the mechanical properties (output responses) of the welded AA5754 H111 aluminum plates. The optimization of technological parameters is a basic requirement for increasing the seam quality, since it promotes a stable and defect-free process. Both the tool rotation and the travel speed, the position of the samples extracted from the weld bead and the thermal data, detected with thermographic techniques for on-line control of the joints, were varied to build the experimental plans. The quality of joints was evaluated through destructive and non-destructive tests (visual tests, macro graphic analysis, tensile tests, indentation Vickers hardness tests and t thermographic controls). The simulation model was based on the adoption of the Artificial Neural Networks (ANNs) characterized by back-propagation learning algorithm with different types of architecture, which were able to predict with good reliability the FSW process parameters for the welding of the AA5754 H111 aluminum plates in Butt-Joint configuration. PMID:28774035

  6. Some bivariate distributions for modeling the strength properties of lumber

    Treesearch

    Richard A. Johnson; James W. Evans; David W. Green

    Accurate modeling of the joint stochastic nature of the strength properties of dimension lumber is essential to the determination of reliability-based design safety factors. This report reviews the major techniques for obtaining bivariate distributions and then discusses bivariate distributions whose marginal distributions suggest they might be useful for modeling the...

  7. A maximum entropy fracture model for low and high strain-rate fracture in TinSilverCopper alloys

    NASA Astrophysics Data System (ADS)

    Chan, Dennis K.

    SnAgCu solder alloys exhibit significant rate-dependent constitutive behavior. Solder joints made of these alloys exhibit failure modes that are also rate-dependent. Solder joints are an integral part of microelectronic packages and are subjected to a wide variety of loading conditions which range from thermo-mechanical fatigue to impact loading. Consequently, there is a need for non-empirical rate-dependent failure theory that is able to accurately predict fracture in these solder joints. In the present thesis, various failure models are first reviewed. But, these models are typically empirical or are not valid for solder joints due to limiting assumptions such as elastic behavior. Here, the development and validation of a maximum entropy fracture model (MEFM) valid for low strain-rate fracture in SnAgCu solders is presented. To this end, work on characterizing SnAgCu solder behavior at low strain-rates using a specially designed tester to estimate parameters for constitutive models is presented. Next, the maximum entropy fracture model is reviewed. This failure model uses a single damage accumulation parameter and relates the risk of fracture to accumulated inelastic dissipation. A methodology is presented to extract this model parameter through a custom-built microscale mechanical tester for Sn3.8Ag0.7Cu solder. This single parameter is used to numerically simulate fracture in two solder joints with entirely different geometries. The simulations are compared to experimentally observed fracture in these same packages. Following the simulations of fracture at low strain rate, the constitutive behavior of solder alloys across nine decades of strain rates through MTS compression tests and split-Hopkinson bar are presented. Preliminary work on using orthogonal machining as novel technique of material characterization at high strain rates is also presented. The resultant data from the MTS compression and split-Hopkinson bar tester is used to demonstrate the localization of stress to the interface of solder joints at high strain rates. The MEFM is further extended to predict failure in brittle materials. Such an extension allows for fracture prediction within intermetallic compounds (IMCs) in solder joints. It has been experimentally observed that the failure mode shifts from bulk solder to the IMC layer with increasing loading rates. The extension of the MEFM would allow for prediction of the fracture mode within the solder joint under different loading conditions. A fracture model capable of predicting failure modes at higher strain rates is necessary, as mobile electronics are becoming ubiquitous. Mobile devices are prone to being dropped which can induce loading rates within solder joints that are much larger than experienced under thermo-mechanical fatigue. A range of possible damage accumulation parameters for Cu6Sn 5 is determined for the MEFM. A value within the aforementioned range is used to demonstrate the increasing likelihood of IMC fracture in solder joints with larger loading rates. The thesis is concluded with remarks about ongoing work that include determining a more accurate damage accumulation parameter for Cu6Sn 5 IMC, and on using machining as a technique for extracting failure parameters for the MEFM.

  8. A microstructurally based model of solder joints under conditions of thermomechanical fatigue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frear, D.R.; Burchett, S.N.; Rashid, M.M.

    The thermomechanical fatigue failure of solder joints in increasingly becoming an important reliability issue. In this paper we present two computational methodologies that have been developed to predict the behavior of near eutectic Sn-Pb solder joints under fatigue conditions that are based on metallurgical tests as fundamental input for constitutive relations. The two-phase model mathematically predicts the heterogeneous coarsening behavior of near eutectic Sn-Pb solder. The finite element simulations from this model agree well with experimental thermomechanical fatigue tests. The simulations show that the presence of an initial heterogeneity in the solder microstructure could significantly degrade the fatigue lifetime. Themore » single phase model is a computational technique that was developed to predict solder joint behavior using materials data for constitutive relation constants that could be determined through straightforward metallurgical experiments. A shear/torsion test sample was developed to impose strain in two different orientations. Materials constants were derived from these tests and the results showed an adequate fit to experimental results. The single-phase model could be very useful for conditions where microstructural evolution is not a dominant factor in fatigue.« less

  9. From Weakly Chaotic Dynamics to Deterministic Subdiffusion via Copula Modeling

    NASA Astrophysics Data System (ADS)

    Nazé, Pierre

    2018-03-01

    Copula modeling consists in finding a probabilistic distribution, called copula, whereby its coupling with the marginal distributions of a set of random variables produces their joint distribution. The present work aims to use this technique to connect the statistical distributions of weakly chaotic dynamics and deterministic subdiffusion. More precisely, we decompose the jumps distribution of Geisel-Thomae map into a bivariate one and determine the marginal and copula distributions respectively by infinite ergodic theory and statistical inference techniques. We verify therefore that the characteristic tail distribution of subdiffusion is an extreme value copula coupling Mittag-Leffler distributions. We also present a method to calculate the exact copula and joint distributions in the case where weakly chaotic dynamics and deterministic subdiffusion statistical distributions are already known. Numerical simulations and consistency with the dynamical aspects of the map support our results.

  10. An Approximation Solution to Refinery Crude Oil Scheduling Problem with Demand Uncertainty Using Joint Constrained Programming

    PubMed Central

    Duan, Qianqian; Yang, Genke; Xu, Guanglin; Pan, Changchun

    2014-01-01

    This paper is devoted to develop an approximation method for scheduling refinery crude oil operations by taking into consideration the demand uncertainty. In the stochastic model the demand uncertainty is modeled as random variables which follow a joint multivariate distribution with a specific correlation structure. Compared to deterministic models in existing works, the stochastic model can be more practical for optimizing crude oil operations. Using joint chance constraints, the demand uncertainty is treated by specifying proximity level on the satisfaction of product demands. However, the joint chance constraints usually hold strong nonlinearity and consequently, it is still hard to handle it directly. In this paper, an approximation method combines a relax-and-tight technique to approximately transform the joint chance constraints to a serial of parameterized linear constraints so that the complicated problem can be attacked iteratively. The basic idea behind this approach is to approximate, as much as possible, nonlinear constraints by a lot of easily handled linear constraints which will lead to a well balance between the problem complexity and tractability. Case studies are conducted to demonstrate the proposed methods. Results show that the operation cost can be reduced effectively compared with the case without considering the demand correlation. PMID:24757433

  11. An approximation solution to refinery crude oil scheduling problem with demand uncertainty using joint constrained programming.

    PubMed

    Duan, Qianqian; Yang, Genke; Xu, Guanglin; Pan, Changchun

    2014-01-01

    This paper is devoted to develop an approximation method for scheduling refinery crude oil operations by taking into consideration the demand uncertainty. In the stochastic model the demand uncertainty is modeled as random variables which follow a joint multivariate distribution with a specific correlation structure. Compared to deterministic models in existing works, the stochastic model can be more practical for optimizing crude oil operations. Using joint chance constraints, the demand uncertainty is treated by specifying proximity level on the satisfaction of product demands. However, the joint chance constraints usually hold strong nonlinearity and consequently, it is still hard to handle it directly. In this paper, an approximation method combines a relax-and-tight technique to approximately transform the joint chance constraints to a serial of parameterized linear constraints so that the complicated problem can be attacked iteratively. The basic idea behind this approach is to approximate, as much as possible, nonlinear constraints by a lot of easily handled linear constraints which will lead to a well balance between the problem complexity and tractability. Case studies are conducted to demonstrate the proposed methods. Results show that the operation cost can be reduced effectively compared with the case without considering the demand correlation.

  12. A Study of Longitudinal Joint Construction Techniques in HMA Pavements (Interim Report - Colorado Project)

    DOT National Transportation Integrated Search

    1996-02-01

    There is a need to identify suitable longitudinal joint construction techniques for multilane hot mix asphalt (HMA) pavements, which can minimize or eliminate cracking at the joint and/or ravelling adjacent to the joint. It is believed that the longi...

  13. Shoulder model validation and joint contact forces during wheelchair activities.

    PubMed

    Morrow, Melissa M B; Kaufman, Kenton R; An, Kai-Nan

    2010-09-17

    Chronic shoulder impingement is a common problem for manual wheelchair users. The loading associated with performing manual wheelchair activities of daily living is substantial and often at a high frequency. Musculoskeletal modeling and optimization techniques can be used to estimate the joint contact forces occurring at the shoulder to assess the soft tissue loading during an activity and to possibly identify activities and strategies that place manual wheelchair users at risk for shoulder injuries. The purpose of this study was to validate an upper extremity musculoskeletal model and apply the model to wheelchair activities for analysis of the estimated joint contact forces. Upper extremity kinematics and handrim wheelchair kinetics were measured over three conditions: level propulsion, ramp propulsion, and a weight relief lift. The experimental data were used as input to a subject-specific musculoskeletal model utilizing optimization to predict joint contact forces of the shoulder during all conditions. The model was validated using a mean absolute error calculation. Model results confirmed that ramp propulsion and weight relief lifts place the shoulder under significantly higher joint contact loading than level propulsion. In addition, they exhibit large superior contact forces that could contribute to impingement. This study highlights the potential impingement risk associated with both the ramp and weight relief lift activities. Level propulsion was shown to have a low relative risk of causing injury, but with consideration of the frequency with which propulsion is performed, this observation is not conclusive.

  14. Slant path rain attenuation and path diversity statistics obtained through radar modeling of rain structure

    NASA Technical Reports Server (NTRS)

    Goldhirsh, J.

    1984-01-01

    Single and joint terminal slant path attenuation statistics at frequencies of 28.56 and 19.04 GHz have been derived, employing a radar data base obtained over a three-year period at Wallops Island, VA. Statistics were independently obtained for path elevation angles of 20, 45, and 90 deg for purposes of examining how elevation angles influences both single-terminal and joint probability distributions. Both diversity gains and autocorrelation function dependence on site spacing and elevation angles were determined employing the radar modeling results. Comparisons with other investigators are presented. An independent path elevation angle prediction technique was developed and demonstrated to fit well with the radar-derived single and joint terminal radar-derived cumulative fade distributions at various elevation angles.

  15. Evaluation of traction stirrup distraction technique to increase the joint space of the shoulder joint in the dog: A cadaveric study.

    PubMed

    Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J

    2015-06-01

    The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Numerical Modeling of Earthquake-Induced Landslide Using an Improved Discontinuous Deformation Analysis Considering Dynamic Friction Degradation of Joints

    NASA Astrophysics Data System (ADS)

    Huang, Da; Song, Yixiang; Cen, Duofeng; Fu, Guoyang

    2016-12-01

    Discontinuous deformation analysis (DDA) as an efficient technique has been extensively applied in the dynamic simulation of discontinuous rock mass. In the original DDA (ODDA), the Mohr-Coulomb failure criterion is employed as the judgment principle of failure between contact blocks, and the friction coefficient is assumed to be constant in the whole calculation process. However, it has been confirmed by a host of shear tests that the dynamic friction of rock joints degrades. Therefore, the friction coefficient should be gradually reduced during the numerical simulation of an earthquake-induced rockslide. In this paper, based on the experimental results of cyclic shear tests on limestone joints, exponential regression formulas are fitted for dynamic friction degradation, which is a function of the relative velocity, the amplitude of cyclic shear displacement and the number of its cycles between blocks with an edge-to-edge contact. Then, an improved DDA (IDDA) is developed by implementing the fitting regression formulas and a modified removing technique of joint cohesion, in which the cohesion is removed once the `sliding' or `open' state between blocks appears for the first time, into the ODDA. The IDDA is first validated by comparing with the theoretical solutions of the kinematic behaviors of a sliding block on an inclined plane under dynamic loading. Then, the program is applied to model the Donghekou landslide triggered by the 2008 Wenchuan earthquake in China. The simulation results demonstrate that the dynamic friction degradation of joints has great influences on the runout and velocity of sliding mass. Moreover, the friction coefficient possesses higher impact than the cohesion of joints on the kinematic behaviors of the sliding mass.

  17. Note: Progress on the use of MgB2 superconducting joint technique for the development of MgB2 magnets for magnetic resonance imaging (MRI).

    PubMed

    Kim, Y G; Song, J B; Kim, J C; Kim, J M; Yoo, B H; Yun, S B; Hwang, D Y; Lee, H G

    2017-08-01

    This note presents a superconducting joint technique for the development of MgB 2 magnetic resonance imaging (MRI) magnets. The MgB 2 superconducting joint was fabricated by a powder processing method using Mg and B powders to establish a wire-bulk-wire connection. The joint resistance measured using a field-decay method was <10 -14 Ω, demonstrating that the proposed joint technique could be employed for developing "next-generation" MgB 2 MRI magnets operating in the persistent current mode.

  18. Experimental Characterization of Hysteresis in a Revolute Joint for Precision Deployable Structures

    NASA Technical Reports Server (NTRS)

    Lake, Mark S.; Fung, Jimmy; Gloss, Kevin; Liechty, Derek S.

    1997-01-01

    Recent studies of the micro-dynamic behavior of a deployable telescope metering truss have identified instabilities in the equilibrium shape of the truss in response to low-energy dynamic loading. Analyses indicate that these micro-dynamic instabilities arise from stick-slip friction within the truss joints (e.g., hinges and latches). The present study characterizes the low-magnitude quasi-static load cycle response of the precision revolute joints incorporated in the deployable telescope metering truss, and specifically, the hysteretic response of these joints caused by stick-slip friction within the joint. Detailed descriptions are presented of the test setup and data reduction algorithms, including discussions of data-error sources and data-filtering techniques. Test results are presented from thirteen specimens, and the effects of joint preload and manufacturing tolerances are investigated. Using a simplified model of stick-slip friction, a relationship is made between joint load-cycle behavior and micro-dynamic dimensional instabilities in the deployable telescope metering truss.

  19. Ultrasonic guided wave inspection of Inconel 625 brazed lap joints

    NASA Astrophysics Data System (ADS)

    Comot, Pierre; Bocher, Philippe; Belanger, Pierre

    2016-04-01

    The aerospace industry has been investigating the use of brazing for structural joints, as a mean of reducing cost and weight. There therefore is a need for a rapid, robust, and cost-effective non-destructive testing method for evaluating the structural integrity of the joints. The mechanical strength of brazed joints depends mainly on the amount of brittle phases in their microstructure. Ultrasonic guided waves offer the possibility of detecting brittle phases in joints using spatio-temporal measurements. Moreover, they offer the opportunity to inspect complex shape joints. This study focused on the development of a technique based on ultrasonic guided waves for the inspection of Inconel 625 lap joints brazed with BNi-2 filler metal. A finite element model of a lap joint was used to optimize the inspection parameters and assess the feasibility of detecting the amount of brittle phases in the joint. A finite element parametric study simulating the input signal shape, the center frequency, and the excitation direction was performed. The simulations showed that the ultrasonic guided wave energy transmitted through, and reflected from, the joints was proportional to the amount of brittle phases in the joint.

  20. Analysis of the stress-strain state in single overlap joints using piezo-ceramic actuators

    NASA Astrophysics Data System (ADS)

    Pǎltânea, Veronica; Pǎltânea, Gheorghe; Popovici, Dorina; Jiga, Gabriel; Papanicolaou, George

    2014-05-01

    In this paper is presented a 2D approach to finite element modeling and an analytical calculus of a single lap bonded joint. As adherent material were selected a sheet of wood, aluminum and titanium. For adhesive part were selected Bison Super Wood D3 in case of the wood single lap joint and an epoxy resin type DGEBA-TETA for gluing together aluminum and titanium parts. In the article is described a combined method, which consists in the placement of the piezoelectric actuator inside of the adhesive part, in order to determine the tensile stress in the overlap joint. A comparison between the analytical and numerical results has been achieved through a multiphysics modeling - electrical and mechanical coupled problem. The technique used to calculate the mechanical parameters (First Principal Stress, displacements) was the three-point bending test, where different forces were applied in the mid-span of the structure, in order to maintain a constant displacement rate. The length of the overlap joint was modified from 20 to 50 mm.

  1. Wavelet packets for multi- and hyper-spectral imagery

    NASA Astrophysics Data System (ADS)

    Benedetto, J. J.; Czaja, W.; Ehler, M.; Flake, C.; Hirn, M.

    2010-01-01

    State of the art dimension reduction and classification schemes in multi- and hyper-spectral imaging rely primarily on the information contained in the spectral component. To better capture the joint spatial and spectral data distribution we combine the Wavelet Packet Transform with the linear dimension reduction method of Principal Component Analysis. Each spectral band is decomposed by means of the Wavelet Packet Transform and we consider a joint entropy across all the spectral bands as a tool to exploit the spatial information. Dimension reduction is then applied to the Wavelet Packets coefficients. We present examples of this technique for hyper-spectral satellite imaging. We also investigate the role of various shrinkage techniques to model non-linearity in our approach.

  2. Cranial cruciate ligament injury in the dog: pathophysiology, diagnosis and treatment.

    PubMed

    Jerram, R M; Walker, A M

    2003-08-01

    Cranial cruciate ligament (CCL) disease in the dog is a multifactorial complex problem that requires a thorough understanding of the biomechanics of the stifle joint to be understood. Successful treatment of rupture of the CCL should be based on managing underlying anatomical and conformational abnormalities rather than attempting to eliminate the tibial cranial drawer sign. The cranial and caudal cruciate ligaments, the patella ligament and quadriceps mechanism, the medial and lateral collateral ligaments, the medial and lateral menisci and the joint capsule provide stability of the joint and load-sharing. The function of the stifle is also significantly influenced by the musculature of the pelvic limb. An active model of biomechanics of the stifle has been described that incorporates not only the ligamentous structures of the stifle but also the forces created by weight-bearing and the musculature of the pelvic limb. This model recognises a force called cranial tibial thrust, which occurs during weight-bearing, and causes compression of the femoral condyles against the tibial plateau. In middle-aged, large-breed dogs, forces acting on the CCL together with conformation-related mild hyperextension of the stifle and slightly increased tibial plateau slopes are suspected to cause progressive degeneration of the ligament. Palpation of craniolateral stifle laxity has become pathognomonic for CCL rupture; however, chronic periarticular fibrosis, a partial CCL rupture, and a tense patient, may make evaluation of instability of the stifle difficult. Surgical treatment is broadly separated into three groups: intracapsular, extracapsular, and tibial osteotomy techniques. Tibial osteotomy techniques do not serve to provide stability of the stifle but rather alter the geometry of the joint to eliminate cranial tibial thrust such that functional joint stability is achieved during weight-bearing. Visualisation of both menisci is a critical aspect of CCL surgery, irrespective of the technique being performed. Regardless of the surgical technique employed, approximately 85% of dogs show clinical improvement. However, many of these dogs will demonstrate intermittent pain or lameness. Post-operative management is an integral part of the treatment of CCL rupture, and significant benefits in limb function occur when formalised post-operative physiotherapy is performed.

  3. A new noninvasive controlled intra-articular ankle distraction technique on a cadaver model.

    PubMed

    Aydin, Ahmet T; Ozcanli, Haluk; Soyuncu, Yetkin; Dabak, Tayyar K

    2006-08-01

    Effective joint distraction is crucial in arthroscopic ankle surgery. We describe an effective and controlled intra-articular ankle distraction technique that we have studied by means of a fresh-frozen cadaver model. Using a kyphoplasty balloon, which is currently used in spine surgery, we tried to achieve a controlled distraction. After the fixation of the cadaver model, standard anteromedial and anterolateral portals were used for ankle arthroscopy. From the same portals, the kyphoplasty balloon was inserted and placed in an appropriate position intra-articularly. The necessary amount of distraction was achieved by inflating the kyphoplasty balloon with a pressure regulation pump. All anatomic sites of the ankle joint were easily visualized with the arthroscope during surgery by changing the pressure and the intra-articular position of the kyphoplasty balloon. Ankle distraction was clearly seen on the arthroscopic and image intensifier view. The kyphoplasty balloon is simple to place through the standard portals and the advantage is that it allows easy manipulation of the arthroscopic instruments from the same portal.

  4. Thermal Analysis of a Carbon Fiber Rope Barrier for Use in the Reusable Solid Rocket Motor Nozzle Joint-2

    NASA Technical Reports Server (NTRS)

    Clayton, J. Louie

    2002-01-01

    This study provides development and verification of analysis methods used to assess performance of a carbon fiber rope (CFR) thermal barrier system that is currently being qualified for use in Reusable Solid Rocket Motor (RSRM) nozzle joint-2. Modeled geometry for flow calculations considers the joint to be vented with the porous CFR barriers placed in the 'open' assembly gap. Model development is based on a 1-D volume filling approach where flow resistances (assembly gap and CFRs) are defined by serially connected internal flow and the porous media 'Darcy' relationships. Combustion gas flow rates are computed using the volume filling code by assuming a lumped distribution total joint fill volume on a per linear circumferential inch basis. Gas compressibility, friction and heat transfer are included in the modeling. Gas-to-wall heat transfer is simulated by concurrent solution of the compressible flow equations and a large thermal 2-D finite element (FE) conduction grid. The derived numerical technique loosely couples the FE conduction matrix with the compressible gas flow equations. Free constants that appear in the governing equations are calibrated by parametric model comparison to hot fire subscale test results. The calibrated model is then used to make full-scale motor predictions using RSRM aft dome environments. Model results indicate that CFR thermal barrier systems will provide a thermally benign and controlled pressurization environment for the RSRM nozzle joint-2 primary seal activation.

  5. Thermal Analysis of a Carbon Fiber Rope Barrier for Use in the Reusable Solid Rocket Motor Nozzle Joint-2

    NASA Technical Reports Server (NTRS)

    Clayton, J. Louie; Phelps, Lisa (Technical Monitor)

    2001-01-01

    This study provides for development and verification of analysis methods used to assess performance of a carbon fiber rope (CFR) thermal barrier system that is currently being qualified for use in Reusable Solid Rocket Motor (RSRM) nozzle joint-2. Modeled geometry for flow calculations considers the joint to be vented with the porous CFR barriers placed in the "open' assembly gap. Model development is based on a 1-D volume filling approach where flow resistances (assembly gap and CFRs) are defined by serially connected internal flow and the porous media "Darcy" relationships. Combustion gas flow rates are computed using the volume filling code by assuming a lumped distribution total joint fill volume on a per linear circumferential inch basis. Gas compressibility, friction and heat transfer are included in the modeling. Gas-to-wall heat transfer is simulated by concurrent solution of the compressible flow equations and a large thermal 2-D finite element (FE) conduction grid. The derived numerical technique loosely couples the FE conduction matrix with the compressible gas flow equations, Free constants that appear in the governing equations are calibrated by parametric model comparison to hot fire subscale test results. The calibrated model is then used to make full-scale motor predictions using RSRM aft dome environments. Model results indicate that CFR thermal barrier systems will provide a thermally benign and controlled pressurization environment for the RSRM nozzle joint-2 primary seal activation.

  6. A probabilistic multi-criteria decision making technique for conceptual and preliminary aerospace systems design

    NASA Astrophysics Data System (ADS)

    Bandte, Oliver

    It has always been the intention of systems engineering to invent or produce the best product possible. Many design techniques have been introduced over the course of decades that try to fulfill this intention. Unfortunately, no technique has succeeded in combining multi-criteria decision making with probabilistic design. The design technique developed in this thesis, the Joint Probabilistic Decision Making (JPDM) technique, successfully overcomes this deficiency by generating a multivariate probability distribution that serves in conjunction with a criterion value range of interest as a universally applicable objective function for multi-criteria optimization and product selection. This new objective function constitutes a meaningful Xnetric, called Probability of Success (POS), that allows the customer or designer to make a decision based on the chance of satisfying the customer's goals. In order to incorporate a joint probabilistic formulation into the systems design process, two algorithms are created that allow for an easy implementation into a numerical design framework: the (multivariate) Empirical Distribution Function and the Joint Probability Model. The Empirical Distribution Function estimates the probability that an event occurred by counting how many times it occurred in a given sample. The Joint Probability Model on the other hand is an analytical parametric model for the multivariate joint probability. It is comprised of the product of the univariate criterion distributions, generated by the traditional probabilistic design process, multiplied with a correlation function that is based on available correlation information between pairs of random variables. JPDM is an excellent tool for multi-objective optimization and product selection, because of its ability to transform disparate objectives into a single figure of merit, the likelihood of successfully meeting all goals or POS. The advantage of JPDM over other multi-criteria decision making techniques is that POS constitutes a single optimizable function or metric that enables a comparison of all alternative solutions on an equal basis. Hence, POS allows for the use of any standard single-objective optimization technique available and simplifies a complex multi-criteria selection problem into a simple ordering problem, where the solution with the highest POS is best. By distinguishing between controllable and uncontrollable variables in the design process, JPDM can account for the uncertain values of the uncontrollable variables that are inherent to the design problem, while facilitating an easy adjustment of the controllable ones to achieve the highest possible POS. Finally, JPDM's superiority over current multi-criteria decision making techniques is demonstrated with an optimization of a supersonic transport concept and ten contrived equations as well as a product selection example, determining an airline's best choice among Boeing's B-747, B-777, Airbus' A340, and a Supersonic Transport. The optimization examples demonstrate JPDM's ability to produce a better solution with a higher POS than an Overall Evaluation Criterion or Goal Programming approach. Similarly, the product selection example demonstrates JPDM's ability to produce a better solution with a higher POS and different ranking than the Overall Evaluation Criterion or Technique for Order Preferences by Similarity to the Ideal Solution (TOPSIS) approach.

  7. [Research progress of three-dimensional digital model for repair and reconstruction of knee joint].

    PubMed

    Tong, Lu; Li, Yanlin; Hu, Meng

    2013-01-01

    To review recent advance in the application and research of three-dimensional digital knee model. The recent original articles about three-dimensional digital knee model were extensively reviewed and analyzed. The digital three-dimensional knee model can simulate the knee complex anatomical structure very well. Based on this, there are some developments of new software and techniques, and good clinical results are achieved. With the development of computer techniques and software, the knee repair and reconstruction procedure has been improved, the operation will be more simple and its accuracy will be further improved.

  8. Development of an empirically based dynamic biomechanical strength model

    NASA Technical Reports Server (NTRS)

    Pandya, A.; Maida, J.; Aldridge, A.; Hasson, S.; Woolford, B.

    1992-01-01

    The focus here is on the development of a dynamic strength model for humans. Our model is based on empirical data. The shoulder, elbow, and wrist joints are characterized in terms of maximum isolated torque, position, and velocity in all rotational planes. This information is reduced by a least squares regression technique into a table of single variable second degree polynomial equations determining the torque as a function of position and velocity. The isolated joint torque equations are then used to compute forces resulting from a composite motion, which in this case is a ratchet wrench push and pull operation. What is presented here is a comparison of the computed or predicted results of the model with the actual measured values for the composite motion.

  9. Anisotropic modeling and joint-MAP stitching for improved ultrasound model-based iterative reconstruction of large and thick specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almansouri, Hani; Venkatakrishnan, Singanallur V.; Clayton, Dwight A.

    One-sided non-destructive evaluation (NDE) is widely used to inspect materials, such as concrete structures in nuclear power plants (NPP). A widely used method for one-sided NDE is the synthetic aperture focusing technique (SAFT). The SAFT algorithm produces reasonable results when inspecting simple structures. However, for complex structures, such as heavily reinforced thick concrete structures, SAFT results in artifacts and hence there is a need for a more sophisticated inversion technique. Model-based iterative reconstruction (MBIR) algorithms, which are typically equivalent to regularized inversion techniques, offer a powerful framework to incorporate complex models for the physics, detector miscalibrations and the materials beingmore » imaged to obtain high quality reconstructions. Previously, we have proposed an ultrasonic MBIR method that signifcantly improves reconstruction quality compared to SAFT. However, the method made some simplifying assumptions on the propagation model and did not disucss ways to handle data that is obtained by raster scanning a system over a surface to inspect large regions. In this paper, we propose a novel MBIR algorithm that incorporates an anisotropic forward model and allows for the joint processing of data obtained from a system that raster scans a large surface. We demonstrate that the new MBIR method can produce dramatic improvements in reconstruction quality compared to SAFT and suppresses articfacts compared to the perviously presented MBIR approach.« less

  10. Anisotropic modeling and joint-MAP stitching for improved ultrasound model-based iterative reconstruction of large and thick specimens

    NASA Astrophysics Data System (ADS)

    Almansouri, Hani; Venkatakrishnan, Singanallur; Clayton, Dwight; Polsky, Yarom; Bouman, Charles; Santos-Villalobos, Hector

    2018-04-01

    One-sided non-destructive evaluation (NDE) is widely used to inspect materials, such as concrete structures in nuclear power plants (NPP). A widely used method for one-sided NDE is the synthetic aperture focusing technique (SAFT). The SAFT algorithm produces reasonable results when inspecting simple structures. However, for complex structures, such as heavily reinforced thick concrete structures, SAFT results in artifacts and hence there is a need for a more sophisticated inversion technique. Model-based iterative reconstruction (MBIR) algorithms, which are typically equivalent to regularized inversion techniques, offer a powerful framework to incorporate complex models for the physics, detector miscalibrations and the materials being imaged to obtain high quality reconstructions. Previously, we have proposed an ultrasonic MBIR method that signifcantly improves reconstruction quality compared to SAFT. However, the method made some simplifying assumptions on the propagation model and did not disucss ways to handle data that is obtained by raster scanning a system over a surface to inspect large regions. In this paper, we propose a novel MBIR algorithm that incorporates an anisotropic forward model and allows for the joint processing of data obtained from a system that raster scans a large surface. We demonstrate that the new MBIR method can produce dramatic improvements in reconstruction quality compared to SAFT and suppresses articfacts compared to the perviously presented MBIR approach.

  11. Using detailed inter-network simulation and model abstraction to investigate and evaluate joint battlespace infosphere (JBI) support technologies

    NASA Astrophysics Data System (ADS)

    Green, David M.; Dallaire, Joel D.; Reaper, Jerome H.

    2004-08-01

    The Joint Battlespace Infosphere (JBI) program is performing a technology investigation into global communications, data mining and warehousing, and data fusion technologies by focusing on techniques and methodologies that support twenty first century military distributed collaboration. Advancement of these technologies is vitally important if military decision makers are to have the right data, in the right format, at the right time and place to support making the right decisions within available timelines. A quantitative understanding of individual and combinational effects arising from the application of technologies within a framework is presently far too complex to evaluate at more than a cursory depth. In order to facilitate quantitative analysis under these circumstances, the Distributed Information Enterprise Modeling and Simulation (DIEMS) team was formed to apply modeling and simulation (M&S) techniques to help in addressing JBI analysis challenges. The DIEMS team has been tasked utilizing collaborative distributed M&S architectures to quantitatively evaluate JBI technologies and tradeoffs. This paper first presents a high level view of the DIEMS project. Once this approach has been established, a more concentrated view of the detailed communications simulation techniques used in generating the underlying support data sets is presented.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseren, M.A.

    A rigid body model for the entire system which accounts for the load distribution scheme proposed in Part 1 as well as for the dynamics of the manipulators and the kinematic constraints is derived in the joint space. A technique is presented for expressing the object dynamics in terms of the joint variables of both manipulators which leads to a positive definite and symmetric inertia matrix. The model is then transformed to obtain reduced order equations of motion and a separate set of equations which govern the behavior of the internal contact forces. The control architecture is applied to themore » model which results in the explicit decoupling of the position and internal contact force-controlled degrees of freedom (DOF).« less

  13. Adaptive dynamic surface control of flexible-joint robots using self-recurrent wavelet neural networks.

    PubMed

    Yoo, Sung Jin; Park, Jin Bae; Choi, Yoon Ho

    2006-12-01

    A new method for the robust control of flexible-joint (FJ) robots with model uncertainties in both robot dynamics and actuator dynamics is proposed. The proposed control system is a combination of the adaptive dynamic surface control (DSC) technique and the self-recurrent wavelet neural network (SRWNN). The adaptive DSC technique provides the ability to overcome the "explosion of complexity" problem in backstepping controllers. The SRWNNs are used to observe the arbitrary model uncertainties of FJ robots, and all their weights are trained online. From the Lyapunov stability analysis, their adaptation laws are induced, and the uniformly ultimately boundedness of all signals in a closed-loop adaptive system is proved. Finally, simulation results for a three-link FJ robot are utilized to validate the good position tracking performance and robustness against payload uncertainties and external disturbances of the proposed control system.

  14. Foot positioning instruction, initial vertical load position and lifting technique: effects on low back loading.

    PubMed

    Kingma, Idsart; Bosch, Tim; Bruins, Louis; van Dieën, Jaap H

    2004-10-22

    This study investigated the effects of initial load height and foot placement instruction in four lifting techniques: free, stoop (bending the back), squat (bending the knees) and a modified squat technique (bending the knees and rotating them outward). A 2D dynamic linked segment model was combined with an EMG assisted trunk muscle model to quantify kinematics and low back loading in 10 subjects performing 19 different lifting movements, using 10.5 kg boxes without handles. When lifting from a 0.05 m height with the feet behind the box, squat lifting resulted in 19.9% (SD 8.7%) higher net moments (p < 0.001) and 17.0% (SD 13.2%) higher compression forces (p < 0.01) than stoop lifting. This effect was reduced to 12.8% (SD 10.7%) for moments and a non-significant 7.4% (SD 16.0%) for compression forces when lifting with the feet beside the box and it disappeared when lifting from 0.5 m height. Differences between squat and stoop lifts, as well as the interaction with lifting height, could to a large extent be explained by changes in the horizontal L5/S1 intervertebral joint position relative to the load, the upper body acceleration, and lumbar flexion. Rotating the knees outward during squat lifts resulted in moments and compression forces that were smaller than in squat lifting but larger than in stoop lifting. Shear forces were small ( < 300 N) at the L4/L5 joint and substantial (1100 - 1400 N) but unaffected by lifting technique at the L5/S1 joint. The present results show that the effects of lifting technique on low back loading depend on the task context.

  15. ICG-enhanced imaging of arthritis with an integrated Optical Imaging/X-ray System

    PubMed Central

    Meier, Reinhard; Krug, Christian; Golovko, Daniel; Boddington, Sophie; Piontek, Guido; Rudelius, Martina; Sutton, Elizabeth J.; Baur-Melnyk, Andrea; Jones, Ella F.; Daldrup-Link, Heike E.

    2010-01-01

    Background Optical Imaging (OI) is a promising technique that is quick, inexpensive and, in combination with Indocyanine Green (ICG), an FDA-approved fluorescent dye, could provide early detection of rheumatoid arthritis. Objective The purpose of this study was to evaluate a combined X-ray/OI imaging system for ICG-enhanced detection of arthritic joints in a rat model of antigen induced arthritis. Methods Arthritis of the knee and ankle joints was induced in six Harlan rats with peptidoglycan polysaccharide polymers (PGPS). Three rats served as non-treated controls. Optical imaging of the knee and ankle joints was done with an integrated OI/X-ray system before and up to 24h post intravenous injection (p.i.) of 10mg/kg ICG. The fluorescence signal intensities of arthritic and normal joints were compared for significant differences using generalized estimation equation models. Specimen of knee and ankle joints were further processed and evaluated by histology. Results ICG provided a significant increase in fluorescence signal of arthritic joints compared to baseline values immediately after administration (p<0.05). The fluorescence signal of arthritic joints was significantly higher compared to the non-arthritic control joints at 1 - 720 min p.i. (p<0.05). Fusion of ICG-enhanced OI and X-rays allowed for anatomical co-registration of the inflamed tissue with the associated joint. H&E stains confirmed marked synovial inflammation of arthritic joints and absence of inflammation in control joints. Conclusion ICG-enhanced OI is a clinically applicable tool for detection of arthritic tissue. Using relatively high doses of ICG, a long term fluorescence enhancement of arthritic joints can be achieved. This may facilitate simultaneous evaluations of multiple joints in a clinical setting. Fusion of ICG-OI scans with X-ray imaging increases anatomical resolution. PMID:20506388

  16. A Kinematic Calibration Process for Flight Robotic Arms

    NASA Technical Reports Server (NTRS)

    Collins, Curtis L.; Robinson, Matthew L.

    2013-01-01

    The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.

  17. Slope stability and rockfall assessment of volcanic tuffs using RPAS with 2-D FEM slope modelling

    NASA Astrophysics Data System (ADS)

    Török, Ákos; Barsi, Árpád; Bögöly, Gyula; Lovas, Tamás; Somogyi, Árpád; Görög, Péter

    2018-02-01

    Steep, hardly accessible cliffs of rhyolite tuff in NE Hungary are prone to rockfalls, endangering visitors of a castle. Remote sensing techniques were employed to obtain data on terrain morphology and to provide slope geometry for assessing the stability of these rock walls. A RPAS (Remotely Piloted Aircraft System) was used to collect images which were processed by Pix4D mapper (structure from motion technology) to generate a point cloud and mesh. The georeferencing was made by Global Navigation Satellite System (GNSS) with the use of seven ground control points. The obtained digital surface model (DSM) was processed (vegetation removal) and the derived digital terrain model (DTM) allowed cross sections to be drawn and a joint system to be detected. Joint and discontinuity system was also verified by field measurements. On-site tests as well as laboratory tests provided additional engineering geological data for slope modelling. Stability of cliffs was assessed by 2-D FEM (finite element method). Global analyses of cross sections show that weak intercalating tuff layers may serve as potential slip surfaces. However, at present the greatest hazard is related to planar failure along ENE-WSW joints and to wedge failure. The paper demonstrates that RPAS is a rapid and useful tool for generating a reliable terrain model of hardly accessible cliff faces. It also emphasizes the efficiency of RPAS in rockfall hazard assessment in comparison with other remote sensing techniques such as terrestrial laser scanning (TLS).

  18. Order reduction, identification and localization studies of dynamical systems

    NASA Astrophysics Data System (ADS)

    Ma, Xianghong

    In this thesis methods are developed for performing order reduction, system identification and induction of nonlinear localization in complex mechanical dynamic systems. General techniques are proposed for constructing low-order models of linear and nonlinear mechanical systems; in addition, novel mechanical designs are considered for inducing nonlinear localization phenomena for the purpose of enhancing their dynamical performance. The thesis is in three major parts. In the first part, the transient dynamics of an impulsively loaded multi-bay truss is numerically computed by employing the Direct Global Matrix (DGM) approach. The approach is applicable to large-scale flexible structures with periodicity. Karhunen-Loeve (K-L) decomposition is used to discretize the dynamics of the truss and to create the low-order models of the truss. The leading order K-L modes are recovered by an experiment, which shows the feasibility of K-L based order reduction technique. In the second part of the thesis, nonlinear localization in dynamical systems is studied through two applications. In the seismic base isolation study, it is shown that the dynamics are sensitive to the presence of nonlinear elements and that passive motion confinement can be induced under proper design. In the coupled rod system, numerical simulation of the transient dynamics shows that a nonlinear backlash spring can induce either nonlinear localization or delocalization in the form of beat phenomena. K-L decomposition and poincare maps are utilized to study the nonlinear effects. The study shows that nonlinear localization can be induced in complex structures through backlash. In the third and final part of the thesis, a new technique based on Green!s function method is proposed to identify the dynamics of practical bolted joints. By modeling the difference between the dynamics of the bolted structure and the corresponding unbolted one, one constructs a nonparametric model for the joint dynamics. Two applications are given with a bolted beam and a truss joint in order to show the applicability of the technique.

  19. Joining of Silicon Carbide-Based Ceramics by Reaction Forming Method

    NASA Technical Reports Server (NTRS)

    Singh, M.; Kiser, J. D.

    1997-01-01

    Recently, there has been a surge of interest in the development and testing of silicon-based ceramics and composite components for a number of aerospace and ground based systems. The designs often require fabrication of complex shaped parts which can be quite expensive. One attractive way of achieving this goal is to build up complex shapes by joining together geometrically simple shapes. However, the joints should have good mechanical strength and environmental stability comparable to the bulk materials. These joints should also be able to maintain their structural integrity at high temperatures. In addition, the joining technique should be practical, reliable, and affordable. Thus, joining has been recognized as one of the enabling technologies for the successful utilization of silicon carbide based ceramic components in high temperature applications. Overviews of various joining techniques, i.e., mechanical fastening, adhesive bonding, welding, brazing, and soldering have been provided in recent publications. The majority of the techniques used today are based on the joining of monolithic ceramics with metals either by diffusion bonding, metal brazing, brazing with oxides and oxynitrides, or diffusion welding. These techniques need either very high temperatures for processing or hot pressing (high pressures). The joints produced by these techniques have different thermal expansion coefficients than the ceramic materials, which creates a stress concentration in the joint area. The use temperatures for these joints are around 700 C. Ceramic joint interlayers have been developed as a means of obtaining high temperature joints. These joint interlayers have been produced via pre-ceramic polymers, in-situ displacement reactions, and reaction bonding techniques. Joints produced by the pre-ceramic polymer approach exhibit a large amounts of porosity and poor mechanical properties. On the other hand, hot pressing or high pressures are needed for in-situ displacement reactions and reaction bonding techniques. Due to the equipment required, these techniques are impractical for joining large or complex shaped components.

  20. Investigation into discretization methods of the six-parameter Iwan model

    NASA Astrophysics Data System (ADS)

    Li, Yikun; Hao, Zhiming; Feng, Jiaquan; Zhang, Dingguo

    2017-02-01

    Iwan model is widely applied for the purpose of describing nonlinear mechanisms of jointed structures. In this paper, parameter identification procedures of the six-parameter Iwan model based on joint experiments with different preload techniques are performed. Four kinds of discretization methods deduced from stiffness equation of the six-parameter Iwan model are provided, which can be used to discretize the integral-form Iwan model into a sum of finite Jenkins elements. In finite element simulation, the influences of discretization methods and numbers of Jenkins elements on computing accuracy are discussed. Simulation results indicate that a higher accuracy can be obtained with larger numbers of Jenkins elements. It is also shown that compared with other three kinds of discretization methods, the geometric series discretization based on stiffness provides the highest computing accuracy.

  1. A New Technique for Compensating Joint Limits in a Robot Manipulator

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan; Hickman, Andre; Guo, Ten-Huei

    1996-01-01

    A new robust, optimal, adaptive technique for compensating rate and position limits in the joints of a six degree-of-freedom elbow manipulator is presented. In this new algorithm, the unmet demand as a result of actuator saturation is redistributed among the remaining unsaturated joints. The scheme is used to compensate for inadequate path planning, problems such as joint limiting, joint freezing, or even obstacle avoidance, where a desired position and orientation are not attainable due to an unrealizable joint command. Once a joint encounters a limit, supplemental commands are sent to other joints to best track, according to a selected criterion, the desired trajectory.

  2. Decoupling Identification for Serial Two-Link Two-Inertia System

    NASA Astrophysics Data System (ADS)

    Oaki, Junji; Adachi, Shuichi

    The purpose of our study is to develop a precise model by applying the technique of system identification for the model-based control of a nonlinear robot arm, under taking joint-elasticity into consideration. We previously proposed a systematic identification method, called “decoupling identification,” for a “SCARA-type” planar two-link robot arm with elastic joints caused by the Harmonic-drive® reduction gears. The proposed method serves as an extension of the conventional rigid-joint-model-based identification. The robot arm is treated as a serial two-link two-inertia system with nonlinearity. The decoupling identification method using link-accelerometer signals enables the serial two-link two-inertia system to be divided into two linear one-link two-inertia systems. The MATLAB®'s commands for state-space model estimation are utilized in the proposed method. Physical parameters such as motor inertias, link inertias, joint-friction coefficients, and joint-spring coefficients are estimated through the identified one-link two-inertia systems using a gray-box approach. This paper describes accuracy evaluations using the two-link arm for the decoupling identification method under introducing closed-loop-controlled elements and varying amplitude-setup of identification-input. Experimental results show that the identification method also works with closed-loop-controlled elements. Therefore, the identification method is applicable to a “PUMA-type” vertical robot arm under gravity.

  3. Inverts permittivity and conductivity with structural constraint in GPR FWI based on truncated Newton method

    NASA Astrophysics Data System (ADS)

    Ren, Qianci

    2018-04-01

    Full waveform inversion (FWI) of ground penetrating radar (GPR) is a promising technique to quantitatively evaluate the permittivity and conductivity of near subsurface. However, these two parameters are simultaneously inverted in the GPR FWI, increasing the difficulty to obtain accurate inversion results for both parameters. In this study, I present a structural constrained GPR FWI procedure to jointly invert the two parameters, aiming to force a structural relationship between permittivity and conductivity in the process of model reconstruction. The structural constraint is enforced by a cross-gradient function. In this procedure, the permittivity and conductivity models are inverted alternately at each iteration and updated with hierarchical frequency components in the frequency domain. The joint inverse problem is solved by the truncated Newton method which considering the effect of Hessian operator and using the approximated solution of Newton equation to be the perturbation model in the updating process. The joint inversion procedure is tested by three synthetic examples. The results show that jointly inverting permittivity and conductivity in GPR FWI effectively increases the structural similarities between the two parameters, corrects the structures of parameter models, and significantly improves the accuracy of conductivity model, resulting in a better inversion result than the individual inversion.

  4. Flight motor set 360L001 (STS-26R). (Reconstructed dynamic loads analysis)

    NASA Technical Reports Server (NTRS)

    Call, V. B.

    1989-01-01

    A transient analysis was performed to correlate the predicted versus measured behavior of the Redesigned Solid Rocket Booster (RSRB) during Flight 360L001 (STS-26R) liftoff. Approximately 9 accelerometers, 152 strain gages, and 104 girth gages were bonded to the motors during this event. Prior to Flight 360L001, a finite element model of the RSRB was analyzed to predict the accelerations, strains, and displacements measured by this developmental flight instrumentation (DFI) within an order of magnitude. Subsequently, an analysis has been performed which uses actual Flight 360L001 liftoff loading conditions, and makes more precise predictions for the RSRB structural behavior. Essential information describing the analytical model, analytical techniques used, correlation of the predicted versus measured RSRB behavior, and conclusions, are presented. A detailed model of the RSRB was developed and correlated for use in analyzing the motor behavior during liftoff loading conditions. This finite element model, referred to as the RSRB global model, uses super-element techniques to model all components of the RSRB. The objective of the RSRB global model is to accurately predict deflections and gap openings in the field joints to an accuracy of approximately 0.001 inch. The model of the field joint component was correlated to Referee and Joint Environment Simulation (JES) tests. The accuracy of the assembled RSRB global model was validated by correlation to static-fire tests such DM-8, DM-9, QM-7, and QM-8. This validated RSRB global model was used to predict RSRB structural behavior and joint gap opening during Flight 360L001 liftoff. The results of a transient analysis of the RSRB global model with imposed liftoff loading conditions are presented. Rockwell used many gage measurements to reconstruct the load parameters which were imposed on the RSRB during the Flight 360L001 liftoff. Each load parameter, and its application, is described. Also presented are conclusions and recommendations based on the analysis of this load case and the resulting correlation between predicted and measured RSRB structural behavior.

  5. Techniques d'inspection par ondes guidees ultrasonores d'assemblages brases dans des reacteurs aeronautiques =

    NASA Astrophysics Data System (ADS)

    Comot, Pierre

    L'industrie aeronautique, cherche a etudier la possibilite d'utiliser de maniere structurelle des joints brases, dans une optique de reduction de poids et de cout. Le developpement d'une methode d'evaluation rapide, fiable et peu couteuse pour evaluer l'integrite structurelle des joints apparait donc indispensable. La resistance mecanique d'un joint brase dependant principalement de la quantite de phase fragile dans sa microstructure. Les ondes guidees ultrasonores permettent de detecter ce type de phase lorsqu'elles sont couplees a une mesure spatio-temporelle. De plus la nature de ce type d'ondes permet l'inspection de joints ayant des formes complexes. Ce memoire se concentre donc sur le developpement d'une technique basee sur l'utilisation d'ondes guidees ultrasonores pour l'inspection de joints brases a recouvrement d'Inconel 625 avec comme metal d'apport du BNi-2. Dans un premiers temps un modele elements finis du joint a ete utilise pour simuler la propagation des ultrasons et optimiser les parametres d'inspection, la simulation a permis egalement de demontrer la faisabilite de la technique pour la detection de la quantite de phase fragile dans ce type de joints. Les parametres optimises sont la forme de signal d'excitation, sa frequence centrale et la direction d'excitation. Les simulations ont montre que l'energie de l'onde ultrasonore transmise a travers le joint aussi bien que celle reflechie, toutes deux extraites des courbes de dispersion, etaient proportionnelles a la quantite de phase fragile presente dans le joint et donc cette methode permet d'identifier la presence ou non d'une phase fragile dans ce type de joint. Ensuite des experimentations ont ete menees sur trois echantillons typiques presentant differentes quantites de phase fragile dans le joint, pour obtenir ce type d'echantillons differents temps de brasage ont ete utilises (1, 60 et 180 min). Pour cela un banc d'essai automatise a ete developpe permettant d'effectuer une analyse similaire a celle utilisee en simulation. Les parametres experimentaux ayant ete choisis en accord avec l'optimisation effectuee lors des simulations et apres une premiere optimisation du procede experimental. Finalement les resultats experimentaux confirment les resultats obtenus en simulation, et demontrent le potentiel de la methode developpee.

  6. Prediction of medial and lateral contact force of the knee joint during normal and turning gait after total knee replacement.

    PubMed

    Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk

    2016-04-01

    The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.

  7. Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies.

    PubMed

    Liacouras, Peter C; Wayne, Jennifer S

    2007-12-01

    Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.

  8. [Research progress of three-dimensional printing technique in joint surgery].

    PubMed

    Wang, Fuyou; Ren, Xiang; Yang, Liu

    2014-03-01

    To summarize the application status of three-dimensional (3-D) printing technique in joint surgery and look forward to the future research directions. The recent original articles about the application and research of 3-D printing technique in joint surgery were extensively reviewed and analyzed. In clinical applications, 3-D printing technique can provide "tailored" treatment and custom implants for patients, which helps doctors to perform the complex operations easier and more safely; in fundamental research, tissue engineered scaffolds with desirable external shape and internal organization are easily fabricated with 3-D printing technique, which can meet the demand of cell adherence and proliferation. Even more, cells may be deposited with the biomaterials during the printing. With the development of medical imaging, digital medicine and new materials, 3-D printing technique will have a wider range of applications in joint surgery.

  9. The stock-flow model of spatial data infrastructure development refined by fuzzy logic.

    PubMed

    Abdolmajidi, Ehsan; Harrie, Lars; Mansourian, Ali

    2016-01-01

    The system dynamics technique has been demonstrated to be a proper method by which to model and simulate the development of spatial data infrastructures (SDI). An SDI is a collaborative effort to manage and share spatial data at different political and administrative levels. It is comprised of various dynamically interacting quantitative and qualitative (linguistic) variables. To incorporate linguistic variables and their joint effects in an SDI-development model more effectively, we suggest employing fuzzy logic. Not all fuzzy models are able to model the dynamic behavior of SDIs properly. Therefore, this paper aims to investigate different fuzzy models and their suitability for modeling SDIs. To that end, two inference and two defuzzification methods were used for the fuzzification of the joint effect of two variables in an existing SDI model. The results show that the Average-Average inference and Center of Area defuzzification can better model the dynamics of SDI development.

  10. Understanding the joint behavior of temperature and precipitation for climate change impact studies

    NASA Astrophysics Data System (ADS)

    Rana, Arun; Moradkhani, Hamid; Qin, Yueyue

    2017-07-01

    The multiple downscaled scenario products allow us to assess the uncertainty of the variations of precipitation and temperature in the current and future periods. Probabilistic assessments of both climatic variables help better understand the interdependence of the two and thus, in turn, help in assessing the future with confidence. In the present study, we use ensemble of statistically downscaled precipitation and temperature from various models. The dataset used is multi-model ensemble of 10 global climate models (GCMs) downscaled product from CMIP5 daily dataset using the Bias Correction and Spatial Downscaling (BCSD) technique, generated at Portland State University. The multi-model ensemble of both precipitation and temperature is evaluated for dry and wet periods for 10 sub-basins across Columbia River Basin (CRB). Thereafter, copula is applied to establish the joint distribution of two variables on multi-model ensemble data. The joint distribution is then used to estimate the change in trends of said variables in future, along with estimation of the probabilities of the given change. The joint distribution trends vary, but certainly positive, for dry and wet periods in sub-basins of CRB. Dry season, generally, is indicating a higher positive change in precipitation than temperature (as compared to historical) across sub-basins with wet season inferring otherwise. Probabilities of changes in future, as estimated from the joint distribution, indicate varied degrees and forms during dry season whereas the wet season is rather constant across all the sub-basins.

  11. Modeling the finger joint moments in a hand at the maximal isometric grip: the effects of friction.

    PubMed

    Wu, John Z; Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E

    2009-12-01

    The interaction between the handle and operator's hand affects the comfort and safety of tool and machine operations. In most of the previous studies, the investigators considered only the normal contact forces. The effect of friction on the joint moments in fingers has not been analyzed. Furthermore, the observed contact forces have not been linked to the internal musculoskeletal loading in the previous experimental studies. In the current study, we proposed a universal model of a hand to evaluate the joint moments in the fingers during grasping tasks. The hand model was developed on the platform of the commercial software package AnyBody. Only four fingers (index, long, ring, and little finger) were included in the model. The anatomical structure of each finger is comprised of four phalanges (distal, middle, proximal, and metacarpal phalange). The simulations were performed using an inverse dynamics technique. The joint angles and the normal contact forces on each finger section reported by previous researchers were used as inputs, while the joint moments of each finger were predicted. The predicted trends of the dependence of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joint moments on the cylinder diameter agree with those of the contact forces on the fingers observed in the previous experimental study. Our results show that the DIP and PIP joint moments reach their maximums at a cylinder diameter of about 31mm, which is consistent with the trend of the finger contact forces measured in the experiments. The proposed approach will be useful for simulating musculoskeletal loading in the hand for occupational activities, thereby optimizing tool-handle design.

  12. Size effects in tin-based lead-free solder joints: Kinetics of bond formation and mechanical characteristics

    NASA Astrophysics Data System (ADS)

    Abdelhadi, Ousama Mohamed Omer

    Continuous miniaturization of microelectronic interconnects demands smaller joints with comparable microstructural and structural sizes. As the size of joints become smaller, the volume of intermetallics (IMCs) becomes comparable with the joint size. As a result, the kinetics of bond formation changes and the types and thicknesses of IMC phases that form within the constrained region of the bond varies. This dissertation focuses on investigating combination effects of process parameters and size on kinetics of bond formation, resulting microstructure and the mechanical properties of joints that are formed under structurally constrained conditions. An experiment is designed where several process parameters such as time of bonding, temperature, and pressure, and bond thickness as structural chracteristic, are varied at multiple levels. The experiment is then implemented on the process. Scanning electron microscope (SEM) is then utilized to determine the bond thickness, IMC phases and their thicknesses, and morphology of the bonds. Electron backscatter diffraction (EBSD) is used to determine the grain size in different regions, including the bulk solder, and different IMC phases. Physics-based analytical models have been developed for growth kinetics of IMC compounds and are verified using the experimental results. Nanoindentation is used to determine the mechanical behavior of IMC phases in joints in different scales. Four-point bending notched multilayer specimen and four-point bending technique were used to determine fracture toughness of the bonds containing IMCs. Analytical modeling of peeling and shear stresses and fracture toughness in tri-layer four-point bend specimen containing intermetallic layer was developed and was verified and validated using finite element simulation and experimental results. The experiment is used in conjunction with the model to calculate and verify the fracture toughness of Cu6Sn5 IMC materials. As expected two different IMC phases, η-phase (Cu6Sn 5) and epsilon-phase (Cu3Sn), were found in almost all the cases regardless of the process parameters and size levels. The physics-based analytical model was successfully able to capture the governing mechanisms of IMC growth: chemical reaction controlled and diffusion-controlled. Examination of microstructures of solder joints of different sizes revealed the size of the solder joint has no effect on the type of IMCs formed during the process. Joint size, however, affected the thickness of IMC layers significantly. IMC layers formed in the solder joints of smaller sizes were found to be thicker than those in the solder joints of larger sizes. The growth rate constants and activation energies of Cu3Sn IMC layer were also reported and related to joint thickness. In an effort to optimize the EBSD imaging in the multi-layer configuration, an improved specimen preparation technique and optimum software parameters were determined. Nanoindentation results show that size effects play a major role on the mechanical properties of micro-scale solder joints. Smaller joints show higher Young's modulus, hardness, and yield strength and lower work hardening exponents comparing to thicker joints. To obtain the stress concentration factors in a multilayer specimen with IMC layer as bonding material, a four-point bending notched configuration was used. The analytical solutions developed for peeling and shear stresses in notched structure were used to evaluate the stresses at IMC interface layers. Results were in good agreement with the finite-element simulation. The values of interfacial stresses were utilized in obtaining fracture toughness of the IMC material. (Abstract shortened by UMI.)

  13. A general model for estimating lower extremity inertial properties of individuals with transtibial amputation.

    PubMed

    Ferris, Abbie E; Smith, Jeremy D; Heise, Gary D; Hinrichs, Richard N; Martin, Philip E

    2017-03-21

    Lower extremity joint moment magnitudes during swing are dependent on the inertial properties of the prosthesis and residual limb of individuals with transtibial amputation (TTA). Often, intact limb inertial properties (INTACT) are used for prosthetic limb values in an inverse dynamics model even though these values overestimate the amputated limb's inertial properties. The purpose of this study was to use subject-specific (SPECIFIC) measures of prosthesis inertial properties to generate a general model (GENERAL) for estimating TTA prosthesis inertial properties. Subject-specific mass, center of mass, and moment of inertia were determined for the shank and foot segments of the prosthesis (n=11) using an oscillation technique and reaction board. The GENERAL model was derived from the means of the SPECIFIC model. Mass and segment lengths are required GENERAL model inputs. Comparisons of segment inertial properties and joint moments during walking were made using three inertial models (unique sample; n=9): (1) SPECIFIC, (2) GENERAL, and (3) INTACT. Prosthetic shank inertial properties were significantly smaller with the SPECIFIC and GENERAL model than the INTACT model, but the SPECIFIC and GENERAL model did not statistically differ. Peak knee and hip joint moments during swing were significantly smaller for the SPECIFIC and GENERAL model compared with the INTACT model and were not significantly different between SPECIFIC and GENERAL models. When subject-specific measures are unavailable, using the GENERAL model produces a better estimate of prosthetic side inertial properties resulting in more accurate joint moment measurements for individuals with TTA than the INTACT model. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Imaging and Analysis of Void-defects in Solder Joints Formed in Reduced Gravity using High-Resolution Computed Tomography

    NASA Technical Reports Server (NTRS)

    Easton, John W.; Struk, Peter M.; Rotella, Anthony

    2008-01-01

    As a part of efforts to develop an electronics repair capability for long duration space missions, techniques and materials for soldering components on a circuit board in reduced gravity must be developed. This paper presents results from testing solder joint formation in low gravity on a NASA Reduced Gravity Research Aircraft. The results presented include joints formed using eutectic tin-lead solder and one of the following fluxes: (1) a no-clean flux core, (2) a rosin flux core, and (3) a solid solder wire with external liquid no-clean flux. The solder joints are analyzed with a computed tomography (CT) technique which imaged the interior of the entire solder joint. This replaced an earlier technique that required the solder joint to be destructively ground down revealing a single plane which was subsequently analyzed. The CT analysis technique is described and results presented with implications for future testing as well as implications for the overall electronics repair effort discussed.

  15. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  16. Preliminayr Study on Diffraction Enhanced Radiographic Imaging for a Canine Model of Cartilage Damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muehleman,C.; Li, J.; Zhong, Z.

    2006-01-01

    Objective: To demonstrate the ability of a novel radiographic technique, Diffraction Enhanced Radiographic Imaging (DEI), to render high contrast images of canine knee joints for identification of cartilage lesions in situ. Methods: DEI was carried out at the X-15A beamline at Brookhaven National Laboratory on intact canine knee joints with varying levels of cartilage damage. Two independent observers graded the DE images for lesions and these grades were correlated to the gross morphological grade. Results: The correlation of gross visual grades with DEI grades for the 18 canine knee joints as determined by observer 1 (r2=0.8856, P=0.001) and observer 2more » (r2=0.8818, P=0.001) was high. The overall weighted ? value for inter-observer agreement was 0.93, thus considered high agreement. Conclusion: The present study is the first study for the efficacy of DEI for cartilage lesions in an animal joint, from very early signs through erosion down to subchondral bone, representing the spectrum of cartilage changes occurring in human osteoarthritis (OA). Here we show that DEI allows the visualization of cartilage lesions in intact canine knee joints with good accuracy. Hence, DEI may be applicable for following joint degeneration in animal models of OA.« less

  17. Joint use of over- and under-sampling techniques and cross-validation for the development and assessment of prediction models.

    PubMed

    Blagus, Rok; Lusa, Lara

    2015-11-04

    Prediction models are used in clinical research to develop rules that can be used to accurately predict the outcome of the patients based on some of their characteristics. They represent a valuable tool in the decision making process of clinicians and health policy makers, as they enable them to estimate the probability that patients have or will develop a disease, will respond to a treatment, or that their disease will recur. The interest devoted to prediction models in the biomedical community has been growing in the last few years. Often the data used to develop the prediction models are class-imbalanced as only few patients experience the event (and therefore belong to minority class). Prediction models developed using class-imbalanced data tend to achieve sub-optimal predictive accuracy in the minority class. This problem can be diminished by using sampling techniques aimed at balancing the class distribution. These techniques include under- and oversampling, where a fraction of the majority class samples are retained in the analysis or new samples from the minority class are generated. The correct assessment of how the prediction model is likely to perform on independent data is of crucial importance; in the absence of an independent data set, cross-validation is normally used. While the importance of correct cross-validation is well documented in the biomedical literature, the challenges posed by the joint use of sampling techniques and cross-validation have not been addressed. We show that care must be taken to ensure that cross-validation is performed correctly on sampled data, and that the risk of overestimating the predictive accuracy is greater when oversampling techniques are used. Examples based on the re-analysis of real datasets and simulation studies are provided. We identify some results from the biomedical literature where the incorrect cross-validation was performed, where we expect that the performance of oversampling techniques was heavily overestimated.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseren, M.A.

    The report reviews a method for modeling and controlling two serial link manipulators which mutually lift and transport a rigid body object in a three dimensional workspace. A new vector variable is introduced which parameterizes the internal contact force controlled degrees of freedom. A technique for dynamically distributing the payload between the manipulators is suggested which yields a family of solutions for the contact forces and torques the manipulators impart to the object. A set of rigid body kinematic constraints which restricts the values of the joint velocities of both manipulators is derived. A rigid body dynamical model for themore » closed chain system is first developed in the joint space. The model is obtained by generalizing the previous methods for deriving the model. The joint velocity and acceleration variables in the model are expressed in terms of independent pseudovariables. The pseudospace model is transformed to obtain reduced order equations of motion and a separate set of equations governing the internal components of the contact forces and torques. A theoretic control architecture is suggested which explicitly decouples the two sets of equations comprising the model. The controller enables the designer to develop independent, non-interacting control laws for the position control and internal force control of the system.« less

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unseren, M.A.

    The paper reviews a method for modeling and controlling two serial link manipulators which mutually lift and transport a rigid body object in a three dimensional workspace. A new vector variable is introduced which parameterizes the internal contact force controlled degrees of freedom. A technique for dynamically distributing the payload between the manipulators is suggested which yields a family of solutions for the contact forces and torques the manipulators impart to the object. A set of rigid body kinematic constraints which restrict the values of the joint velocities of both manipulators is derived. A rigid body dynamical model for themore » closed chain system is first developed in the joint space. The model is obtained by generalizing the previous methods for deriving the model. The joint velocity and acceleration variables in the model are expressed in terms of independent pseudovariables. The pseudospace model is transformed to obtain reduced order equations of motion and a separate set of equations governing the internal components of the contact forces and torques. A theoretic control architecture is suggested which explicitly decouples the two sets of equations comprising the model. The controller enables the designer to develop independent, non-interacting control laws for the position control and internal force control of the system.« less

  20. The Influence of Joint Distraction Force on the Soft-Tissue Balance Using Modified Gap-Balancing Technique in Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Takeoka, Yoshiki; Tsubosaka, Masanori; Kuroda, Ryosuke; Matsumoto, Tomoyuki

    2017-10-01

    During modified gap-balancing technique, there is no consensus on the best method for obtaining appropriate soft-tissue balance and determining the femoral component rotation. Sixty-five varus osteoarthritic patients underwent primary posterior-stabilized total knee arthroplasty using modified gap-balancing technique. The influence of joint distraction force on the soft-tissue balance measurement during the modified gap-balancing technique was evaluated with Offset Repo-Tensor between the osteotomized surfaces at extension, and between femoral posterior condyles and tibial osteotomized surface at flexion of the knee before the resection of femoral posterior condyles. The joint center gap (millimeters) and varus ligament balance (°) were measured under 20, 40, and 60 pounds of joint distraction forces, and the differences in these values at extension and flexion (the value at flexion minus the value at extension) were also calculated. The differences in joint center gap (-6.7, -6.8, and -6.9 mm for 20, 40, and 60 pounds, respectively) and varus ligament balance (3.5°, 3.8°, and 3.8°) at extension and flexion were not significantly different among different joint distraction forces, although the joint center gap and varus ligament balance significantly increased stepwise at extension and flexion as the joint distraction force increased. The difference in joint center gap and varus ligament balance at extension and flexion were consistent even among the different joint distraction forces. This novel index would be useful for the determination of femoral component rotation during the modified gap-balancing technique. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.

    PubMed

    Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk

    2015-06-01

    Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.

  2. Data assimilation of ground GPG total electron content into a physics-based ionosheric model by use of the Kalman filter

    NASA Technical Reports Server (NTRS)

    Hajj, G. A.; Wilson, B. D.; Wang, C.; Pi, X.; Rosen, I. G.

    2004-01-01

    A three-dimensional (3-D) Global Assimilative Ionospheric Model (GAIM) is currently being developed by a joint University of Southern California and Jet Propulsion Laboratory (JPL) team. To estimate the electron density on a global grid, GAIM uses a first-principles ionospheric physics model and the Kalman filter as one of its possible estimation techniques.

  3. A crossover trial evaluating an educational-behavioural joint protection programme for people with rheumatoid arthritis.

    PubMed

    Hammond, A; Lincoln, N; Sutcliffe, L

    1999-05-01

    Joint protection (JP) is a self-management technique widely taught to people with rheumatoid arthritis (RA). JP education aims to enable people with RA to reduce pain, inflammation, joint stress and reduce risks of deformity through using assistive devices and alternative movement patterns of affected joints to perform everyday activities. Previous studies evaluating JP education methods common in the UK have identified JP adherence is poor. A group education programme was developed using the Health Belief Model and Self-efficacy Theory. Strategies used to maximise JP adherence included goal-setting, contracting, modelling, homework programmes, motor learning theory, recall enhancing methods and mental practice. A crossover trial (n = 35) was conducted. Adherence with JP was measured using an objective observational test (the Joint Protection Behaviour Assessment). Significant improvements in use of JP were recorded at 12 and 24 weeks post-education (P < 0.01). No significant changes in measures of pain, functional disability, grip strength, self-efficacy or helplessness occurred post-education, although this may have been due to the small sample size recruited. In conclusion, JP adherence can be facilitated through the use of educational-behavioural strategies, suggesting this approach should be more widely adopted in clinical practice.

  4. Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection.

    PubMed

    Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon

    2015-01-01

    Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success rate of sacroiliac intraarticular injections with the upper one-third joint technique was 90% (18/20). This was an observational study and lacked a control group. Sacroiliac intraarticular injections with the upper one-third joint technique are advisable when it is hard to perform them with the lower one-third joint technique.

  5. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. MRI-based modeling for radiocarpal joint mechanics: validation criteria and results for four specimen-specific models.

    PubMed

    Fischer, Kenneth J; Johnson, Joshua E; Waller, Alexander J; McIff, Terence E; Toby, E Bruce; Bilgen, Mehmet

    2011-10-01

    The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations. Only the model for one specimen met the validation criteria for average and peak pressure of both articulations; however the experimental measures for peak pressure also exhibited high variability. MRI-based modeling can reliably be used for evaluating the contact area and contact force with similar confidence as in currently available experimental techniques. Average contact pressure, and peak contact pressure were more variable from all measurement techniques, and these measures from MRI-based modeling should be used with some caution.

  7. Methode d'identification parametrique pour la surveillance in situ des joints a recouvrement par propagation d'ondes vibratoires

    NASA Astrophysics Data System (ADS)

    Francoeur, Dany

    Cette these de doctorat s'inscrit dans le cadre de projets CRIAQ (Consortium de recherche et d'innovation en aerospatiale du Quebec) orientes vers le developpement d'approches embarquees pour la detection de defauts dans des structures aeronautiques. L'originalite de cette these repose sur le developpement et la validation d'une nouvelle methode de detection, quantification et localisation d'une entaille dans une structure de joint a recouvrement par la propagation d'ondes vibratoires. La premiere partie expose l'etat des connaissances sur l'identification d'un defaut dans le contexte du Structural Health Monitoring (SHM), ainsi que la modelisation de joint a recouvrements. Le chapitre 3 developpe le modele de propagation d'onde d'un joint a recouvrement endommage par une entaille pour une onde de flexion dans la plage des moyennes frequences (10-50 kHz). A cette fin, un modele de transmission de ligne (TLM) est realise pour representer un joint unidimensionnel (1D). Ce modele 1D est ensuite adapte a un joint bi-dimensionnel (2D) en faisant l'hypothese d'un front d'onde plan incident et perpendiculaire au joint. Une methode d'identification parametrique est ensuite developpee pour permettre a la fois la calibration du modele du joint a recouvrement sain, la detection puis la caracterisation de l'entaille situee sur le joint. Cette methode est couplee a un algorithme qui permet une recherche exhaustive de tout l'espace parametrique. Cette technique permet d'extraire une zone d'incertitude reliee aux parametres du modele optimal. Une etude de sensibilite est egalement realisee sur l'identification. Plusieurs resultats de mesure sur des joints a recouvrements 1D et 2D sont realisees permettant ainsi l'etude de la repetabilite des resultats et la variabilite de differents cas d'endommagement. Les resultats de cette etude demontrent d'abord que la methode de detection proposee est tres efficace et permet de suivre la progression d'endommagement. De tres bons resultats de quantification et de localisation d'entailles ont ete obtenus dans les divers joints testes (1D et 2D). Il est prevu que l'utilisation d'ondes de Lamb permettraient d'etendre la plage de validite de la methode pour de plus petits dommages. Ces travaux visent d'abord la surveillance in-situ des structures de joint a recouvrements, mais d'autres types de defauts. (comme les disbond) et. de structures complexes sont egalement envisageables. Mots cles : joint a recouvrement, surveillance in situ, localisation et caracterisation de dommages

  8. Advanced Multivariate Inversion Techniques for High Resolution 3D Geophysical Modeling (Invited)

    NASA Astrophysics Data System (ADS)

    Maceira, M.; Zhang, H.; Rowe, C. A.

    2009-12-01

    We focus on the development and application of advanced multivariate inversion techniques to generate a realistic, comprehensive, and high-resolution 3D model of the seismic structure of the crust and upper mantle that satisfies several independent geophysical datasets. Building on previous efforts of joint invesion using surface wave dispersion measurements, gravity data, and receiver functions, we have added a fourth dataset, seismic body wave P and S travel times, to the simultaneous joint inversion method. We present a 3D seismic velocity model of the crust and upper mantle of northwest China resulting from the simultaneous, joint inversion of these four data types. Surface wave dispersion measurements are primarily sensitive to seismic shear-wave velocities, but at shallow depths it is difficult to obtain high-resolution velocities and to constrain the structure due to the depth-averaging of the more easily-modeled, longer-period surface waves. Gravity inversions have the greatest resolving power at shallow depths, and they provide constraints on rock density variations. Moreover, while surface wave dispersion measurements are primarily sensitive to vertical shear-wave velocity averages, body wave receiver functions are sensitive to shear-wave velocity contrasts and vertical travel-times. Addition of the fourth dataset, consisting of seismic travel-time data, helps to constrain the shear wave velocities both vertically and horizontally in the model cells crossed by the ray paths. Incorporation of both P and S body wave travel times allows us to invert for both P and S velocity structure, capitalizing on empirical relationships between both wave types’ seismic velocities with rock densities, thus eliminating the need for ad hoc assumptions regarding the Poisson ratios. Our new tomography algorithm is a modification of the Maceira and Ammon joint inversion code, in combination with the Zhang and Thurber TomoDD (double-difference tomography) program.

  9. [Comparative ultrasound visualization of clinically relevant structures for evaluating the infant hip joint utilizing trapezoidal vs. parallel transducers].

    PubMed

    Wunsch, R; Wegener-Panzer, A; Reinehr, T; Aurisch, E; Cleaveland, B; Wunsch, C; Dudwiesus, H

    2011-01-01

    Sonographic evaluation of the infant hip joint according to the method of Graf has proven to be an important pediatric investigative instrument. Our goal was to investigate quantitatively whether (and in what ways) the clinically relevant infant hip joint structures visualize differently when utilizing trapezoidal as opposed to linear transducers. Our approach was both theoretical via a mathematical model and practical with in-vivo measurements in neonates. In a prospective study: 1. theoretical and computed analyses were performed for both linear and trapezoidal transducers regarding their respective accuracy for demonstrating the anatomic geometry of the infant hip, assuming not only correctly centered transducer positioning but also cases with off-centered displacement in the cranial or caudal direction; 2. both hip joints in 97 infants were examined by experienced investigators with comparison of the results for parallel vs. trapezoidal transducers. Theoretical mathematical error analysis reveals no intrinsic systemic deviations between trapezoidal vs. parallel transducers in US scanning of the infant hip and furthermore no inherent disadvantages in the trapezoidal technique. Even when off-center transducer alignments of 1.5 cm are employed in the mathematical models, there is no significant relative distortion of the required anatomic structures when comparing the characteristics of both transducers. The practical in-vivo data from our 97 neonates confirmed the theoretical considerations. No loss of accuracy or other negative factors are evident when trapezoidal transducers are used to visualize the infant hip joint in comparison with the customary parallel technique. There are no significantly measurable differences between the two approaches. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Shear fracture of jointed steel plates of bolted joints under impact load

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.; Kobayashi, H.; Shin, H.-S.

    2013-07-01

    The present study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of bolted joints used in a car body, which contributes to crash simulations by CAE. We focus our attention on the shear fracture of the jointed steel plates of lap-bolted joints in the suspension of a car under impact load. Members of lap-bolted joints are modelled as a pair of steel plates connected by a bolt. One of the plates is a specimen subjected to plastic deformation and fracture and the other is a jig subjected to elastic deformation only. Three kinds of steel plate specimens are examined, i.e., a common steel plate with a tensile strength of 270 MPa and high tensile strength steel plates of 440 and 590 MPa used for cars. The impact shear test was performed using the split Hopkinson bar technique for tension impact, together with the static test using a universal testing machine INSTRON 5586. The behaviour of the shear stress and deformation up to rupture taking place in the joint was discussed. The obtained results suggest that a stress-based fracture criterion may be developed for the impact fracture of jointed steel plates of a lap-bolted joint.

  11. Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.

    PubMed

    Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A

    2011-11-01

    Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.

  12. Superior Recess Access of the Lumbar Facet Joint.

    PubMed

    Demir-Deviren, Sibel; Singh, Sukhminder; Hanelin, Joshua

    2017-04-01

    Descriptive approach to accessing the lumbar facet joint by superior recess. This study is aimed to describe an approach to accessing the lumbar facet joint through targeting the superior recess during lumbar facet joint injections. Lumbar facet joint injections are routinely performed for both the diagnosis and treatment of chronic low back pain. Previous studies either did not specify which part of the joint to target, or recommended targeting the inferior aspect of the joint to access the inferior recess. One study did mention the superior recess as an alternative to injecting the inferior recess, but none has focused on description of the technique. This is the first time this technique has been described. The records and fluoroscopic images were reviewed for all patients over a period of 9 months (January-September 2012) using the proposed technique. This resulted in a total of 48 patients; 15 men, 29 women, and a total of 117 facet joint intra-articular injections. Among these 48 patients, injections were repeated in total of 4 cases. The average time of injections among 4 repeat cases was 121 days. The success of the procedure was confirmed with an arthrogram demonstrating contrast flowing from the superior recess inferiorly through the joint space. Successful access of the lumbar facet joint through puncture of the superior recess was seen in 114 cases, with 3 unsuccessful attempts to enter facet joints due to osteophytes at involved levels. There were no complications observed during the procedure. We find this approach to be highly successful, safe, and well tolerated by the patient and recommend it as a technique for access of the lumbar facet joint in those patients in whom direct puncture of the inferior recess is difficult.

  13. Characterization of the bending stiffness of large space structure joints

    NASA Technical Reports Server (NTRS)

    Wu, K. Chauncey

    1989-01-01

    A technique for estimating the bending stiffness of large space structure joints is developed and demonstrated for an erectable joint concept. Experimental load-deflection data from a three-point bending test was used as input to solve a closed-form expression for the joint bending stiffness which was derived from linear beam theory. Potential error sources in both the experimental and analytical procedures are identified and discussed. The bending stiffness of a mechanically preloaded erectable joint is studied at three applied moments and seven joint orientations. Using this technique, the joint bending stiffness was bounded between 6 and 17 percent of the bending stiffness of the graphite/epoxy strut member.

  14. Modeling Anisotropic Elastic Wave Propagation in Jointed Rock Masses

    NASA Astrophysics Data System (ADS)

    Hurley, R.; Vorobiev, O.; Ezzedine, S. M.; Antoun, T.

    2016-12-01

    We present a numerical approach for determining the anisotropic stiffness of materials with nonlinearly-compliant joints capable of sliding. The proposed method extends existing ones for upscaling the behavior of a medium with open cracks and inclusions to cases relevant to natural fractured and jointed rocks, where nonlinearly-compliant joints can undergo plastic slip. The method deviates from existing techniques by incorporating the friction and closure states of the joints, and recovers an anisotropic elastic form in the small-strain limit when joints are not sliding. We present the mathematical formulation of our method and use Representative Volume Element (RVE) simulations to evaluate its accuracy for joint sets with varying complexity. We then apply the formulation to determine anisotropic elastic constants of jointed granite found at the Nevada Nuclear Security Site (NNSS) where the Source Physics Experiments (SPE), a campaign of underground chemical explosions, are performed. Finally, we discuss the implementation of our numerical approach in a massively parallel Lagrangian code Geodyn-L and its use for studying wave propagation from underground explosions. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  15. Forward and Inverse Predictive Model for the Trajectory Tracking Control of a Lower Limb Exoskeleton for Gait Rehabilitation: Simulation modelling analysis

    NASA Astrophysics Data System (ADS)

    Zakaria, M. A.; Majeed, A. P. P. A.; Taha, Z.; Alim, M. M.; Baarath, K.

    2018-03-01

    The movement of a lower limb exoskeleton requires a reasonably accurate control method to allow for an effective gait therapy session to transpire. Trajectory tracking is a nontrivial means of passive rehabilitation technique to correct the motion of the patients’ impaired limb. This paper proposes an inverse predictive model that is coupled together with the forward kinematics of the exoskeleton to estimate the behaviour of the system. A conventional PID control system is used to converge the required joint angles based on the desired input from the inverse predictive model. It was demonstrated through the present study, that the inverse predictive model is capable of meeting the trajectory demand with acceptable error tolerance. The findings further suggest the ability of the predictive model of the exoskeleton to predict a correct joint angle command to the system.

  16. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    PubMed

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  17. Biomechanical Evaluation of Knee Joint Laxities and Graft Forces After Anterior Cruciate Ligament Reconstruction by Anteromedial Portal, Outside-In, and Transtibial Techniques

    PubMed Central

    Sim, Jae Ang; Gadikota, Hemanth R.; Li, Jing-Sheng; Li, Guoan; Gill, Thomas J.

    2013-01-01

    Background Recently, anatomic anterior cruciate ligament (ACL) reconstruction is emphasized to improve joint laxity and to potentially avert initiation of cartilage degeneration. There is a paucity of information on the efficacy of ACL reconstructions by currently practiced tunnel creation techniques in restoring normal joint laxity. Study Design Controlled laboratory study. Hypothesis Anterior cruciate ligament reconstruction by the anteromedial (AM) portal technique, outside-in (OI) technique, and modified transtibial (TT) technique can equally restore the normal knee joint laxity and ACL forces. Methods Eight fresh-frozen human cadaveric knee specimens were tested using a robotic testing system under an anterior tibial load (134 N) at 0°, 30°, 60°, and 90° of flexion and combined torques (10-N·m valgus and 5-N·m internal tibial torques) at 0° and 30° of flexion. Knee joint kinematics, ACL, and ACL graft forces were measured in each knee specimen under 5 different conditions (ACL-intact knee, ACL-deficient knee, ACL-reconstructed knee by AM portal technique, ACL-reconstructed knee by OI technique, and ACL-reconstructed knee by TT technique). Results Under anterior tibial load, no significant difference was observed between the 3 reconstructions in terms of restoring anterior tibial translation (P > .05). However, none of the 3 ACL reconstruction techniques could completely restore the normal anterior tibial translations (P <.05). Under combined tibial torques, both AM portal and OI techniques closely restored the normal knee anterior tibial translation (P > .05) at 0° of flexion but could not do so at 30° of flexion (P <.05). The ACL reconstruction by the TT technique was unable to restore normal anterior tibial translations at both 0° and 30° of flexion under combined tibial torques (P <.05). Forces experienced by the ACL grafts in the 3 reconstruction techniques were lower than those experienced by normal ACL under both the loading conditions. Conclusion Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques are biomechanically comparable with each other in restoring normal knee joint laxity and in situ ACL forces. Clinical Relevance Anterior cruciate ligament reconstructions by AM portal, OI, and modified TT techniques result in similar knee joint laxities. Technical perils and pearls should be carefully considered before choosing a tunnel creating technique. PMID:21908717

  18. The effect of variation in interpretation of the La Trobe radiographic foot atlas on the prevalence of foot osteoarthritis in older women: the Chingford general population cohort.

    PubMed

    McQueen, Peter; Gates, Lucy; Marshall, Michelle; Doherty, Michael; Arden, Nigel; Bowen, Catherine

    2017-01-01

    The prevalence of foot osteoarthritis (OA) is much less understood than hip, knee and hand OA. The foot is anatomically complex and different researchers have investigated different joints with lack of methodological standardisation across studies. The La Trobe Foot Atlas (LFA) is the first to address these issues in providing quantitative assessment of radiographic foot OA, but has not been tested externally. The aim of this study was to evaluate three different interpretive approaches to using the LFA for grading OA when scoring is difficult due to indistinct views of interosseous space and joint contour. Foot radiographs of all remaining participants ( n  = 218) assessed in the Chingford Women Study 23 year visit (mean (SD) for age: 75.5 years (5.1)) were scored using the LFA defined protocol (Technique 1). Two revised scoring strategies were applied to the radiographs in addition to the standard LFA analyses. Technique 2 categorised joints that were difficult to grade as 'missing'. Technique 3 included joints that were difficult to grade as an over estimated score. Radiographic OA prevalence was defined for the foot both collectively and separately for individual joints. When radiographs were scored using the LFA (Technique 1), radiographic foot OA was present in 89.9%. For Technique 2 the presence of radiographic foot OA was 83.5% and for Technique 3 it was 97.2%. At the individual joint level, using Technique 1, the presence of radiographic foot OA was higher with a wider range (18.3-74.3%) than Technique 2 (17.9-46.3%) and lower with a wider range (18.3-74.3%) than Technique 3 (39.9-79.4%). The three different ways of interpreting the LFA scoring system when grading of individual joints is technically difficult and result in very different estimates of foot OA prevalence at both the individual joint and global foot level. Agreement on the best strategy is required to improve comparability between studies.

  19. Development and validation of a periarticular injection technique of the sacroiliac joint in horses.

    PubMed

    Engeli, E; Haussler, K K; Erb, H N

    2004-05-01

    Sacroiliac joint osteoarthritis has been recognised as a significant cause of poor performance in competition and racehorses. Reliable diagnostic tools are currently lacking. The diagnosis has been based typically on exclusion of other possible causes of poor performance, back pain and hindlimb lameness. To develop a safe, reliable and minimally invasive periarticular or intra-articular injection technique of potential use for diagnosis and therapy of sacroiliac joint disease in horses. Twenty-six horses were used to develop and assess a medial approach to the sacroiliac joint with a 15 gauge, 25 cm long spinal needle. In Part I, the cadaveric study, the spinal needle was introduced cranial to the contralateral tuber sacrale and advanced along the medial aspect of the ipsilateral iliac wing until the dorsal surface of the sacrum was encountered. One ml methylene blue (MB) was injected in both sacroiliac joint regions of the sacropelvic specimens. The location of MB-stained tissues relative to the sacroiliac joints was recorded after dissection and disarticulation of the sacroiliac joint. In Part II, the in vivo study, 18 horses were used to validate the in vivo application of the sacroiliac joint injection technique. Horses were restrained in stocks and sedated in preparation for needle placement. One ml MB was injected bilaterally prior to euthanasia. Stained tissues were identified and recorded at necropsy. Successful joint injections were characterised as having MB located intra-articularly or < or = 2 cm periarticularly from the sacroiliac joint margin and localised to the middle or caudal third of the sacroiliac joint. Intra-articular MB was not observed in any specimen. However, MB-stained tissue was identified periarticularly in all injection sites (n = 48). Based on the predetermined success criteria, 96% of the methylene blue depots were located at the middle or caudal third of the sacroiliac joint. Dye-stained tissue was located < or = 2 cm from the sacroiliac joint margins in 88% of the specimens. Median distance of the MB from the sacroiliac joint margins was 1.0 cm (range 0.2-3.8 cm). The overall success rate considering both location and distance of the MB-stained tissue relative to sacroiliac joint margins was 83% (40 of 48 joints). The injection technique provides a reliable, easy to perform and consistent access to the medial periarticular aspect of the sacroiliac joint. The described injection technique has the potential for both diagnostic and therapeutic applications in the medical management of equine sacroiliac joint disease. Further investigation is necessary to evaluate clinical efficacy and potential adverse effects.

  20. Multilayer Joint Gait-Pose Manifolds for Human Gait Motion Modeling.

    PubMed

    Ding, Meng; Fan, Guolian

    2015-11-01

    We present new multilayer joint gait-pose manifolds (multilayer JGPMs) for complex human gait motion modeling, where three latent variables are defined jointly in a low-dimensional manifold to represent a variety of body configurations. Specifically, the pose variable (along the pose manifold) denotes a specific stage in a walking cycle; the gait variable (along the gait manifold) represents different walking styles; and the linear scale variable characterizes the maximum stride in a walking cycle. We discuss two kinds of topological priors for coupling the pose and gait manifolds, i.e., cylindrical and toroidal, to examine their effectiveness and suitability for motion modeling. We resort to a topologically-constrained Gaussian process (GP) latent variable model to learn the multilayer JGPMs where two new techniques are introduced to facilitate model learning under limited training data. First is training data diversification that creates a set of simulated motion data with different strides. Second is the topology-aware local learning to speed up model learning by taking advantage of the local topological structure. The experimental results on the Carnegie Mellon University motion capture data demonstrate the advantages of our proposed multilayer models over several existing GP-based motion models in terms of the overall performance of human gait motion modeling.

  1. Surrogate modeling of deformable joint contact using artificial neural networks.

    PubMed

    Eskinazi, Ilan; Fregly, Benjamin J

    2015-09-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Surrogate Modeling of Deformable Joint Contact using Artificial Neural Networks

    PubMed Central

    Eskinazi, Ilan; Fregly, Benjamin J.

    2016-01-01

    Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. PMID:26220591

  3. Joint inversion of high-frequency surface waves with fundamental and higher modes

    USGS Publications Warehouse

    Luo, Y.; Xia, J.; Liu, J.; Liu, Q.; Xu, S.

    2007-01-01

    Joint inversion of multimode surface waves for estimating the shear (S)-wave velocity has received much attention in recent years. In this paper, we first analyze sensitivity of phase velocities of multimodes of surface waves for a six-layer earth model, and then we invert surface-wave dispersion curves of the theoretical model and a real-world example. Sensitivity analysis shows that fundamental mode data are more sensitive to the S-wave velocities of shallow layers and are concentrated on a very narrow frequency band, while higher mode data are more sensitive to the parameters of relatively deeper layers and are distributed over a wider frequency band. These properties provide a foundation of using a multimode joint inversion to define S-wave velocities. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least-square method and the singular-value decomposition technique to invert high-frequency surface waves with fundamental and higher mode data simultaneously can effectively reduce the ambiguity and improve the accuracy of S-wave velocities. ?? 2007.

  4. The influence of hand positions on biomechanical injury risk factors at the wrist joint during the round-off skills in female gymnastics.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2017-01-01

    The aim of this study was to examine the biomechanical injury risk factors at the wrist, including joint kinetics, kinematics and stiffness in the first and second contact limb for parallel and T-shape round-off (RO) techniques. Seven international-level female gymnasts performed 10 trials of the RO to back handspring with parallel and T-shape hand positions. Synchronised kinematic (3D motion analysis system; 247 Hz) and kinetic (two force plates; 1235 Hz) data were collected for each trial. A two-way repeated measure analysis of variance (ANOVA) assessed differences in the kinematic and kinetic parameters between the techniques for each contact limb. The main findings highlighted that in both the RO techniques, the second contact limb wrist joint is exposed to higher mechanical loads than the first contact limb demonstrated by increased axial compression force and loading rate. In the parallel technique, the second contact limb wrist joint is exposed to higher axial compression load. Differences between wrist joint kinetics highlight that the T-shape technique may potentially lead to reducing these bio-physical loads and consequently protect the second contact limb wrist joint from overload and biological failure. Highlighting the biomechanical risk factors facilitates the process of technique selection making more objective and safe.

  5. Variability of Plyometric and Ballistic Exercise Technique Maintains Jump Performance.

    PubMed

    Chandler, Phillip T; Greig, Matthew; Comfort, Paul; McMahon, John J

    2018-06-01

    Chandler, PT, Greig, M, Comfort, P, and McMahon, JJ. Variability of plyometric and ballistic exercise technique maintains jump performance. J Strength Cond Res 32(6): 1571-1582, 2018-The aim of this study was to investigate changes in vertical jump technique over the course of a training session. Twelve plyometric and ballistic exercise-trained male athletes (age = 23.4 ± 4.6 years, body mass = 78.7 ± 18.8 kg, height = 177.1 ± 9.0 cm) performed 3 sets of 10 repetitions of drop jump (DJ), rebound jump (RJ) and squat jump (SJ). Each exercise was analyzed from touchdown to peak joint flexion and peak joint flexion to take-off. Squat jump was analyzed from peak joint flexion to take-off only. Jump height, flexion and extension time and range of motion, and instantaneous angles of the ankle, knee, and hip joints were measured. Separate 1-way repeated analyses of variance compared vertical jump technique across exercise sets and repetitions. Exercise set analysis found that SJ had lower results than DJ and RJ for the angle at peak joint flexion for the hip, knee, and ankle joints and take-off angle of the hip joint. Exercise repetition analysis found that the ankle joint had variable differences for the angle at take-off, flexion, and extension time for RJ. The knee joint had variable differences for flexion time for DJ and angle at take-off and touchdown for RJ. There was no difference in jump height. Variation in measured parameters across repetitions highlights variable technique across plyometric and ballistic exercises. This did not affect jump performance, but likely maintained jump performance by overcoming constraints (e.g., level of rate coding).

  6. Long memory and multifractality: A joint test

    NASA Astrophysics Data System (ADS)

    Goddard, John; Onali, Enrico

    2016-06-01

    The properties of statistical tests for hypotheses concerning the parameters of the multifractal model of asset returns (MMAR) are investigated, using Monte Carlo techniques. We show that, in the presence of multifractality, conventional tests of long memory tend to over-reject the null hypothesis of no long memory. Our test addresses this issue by jointly estimating long memory and multifractality. The estimation and test procedures are applied to exchange rate data for 12 currencies. Among the nested model specifications that are investigated, in 11 out of 12 cases, daily returns are most appropriately characterized by a variant of the MMAR that applies a multifractal time-deformation process to NIID returns. There is no evidence of long memory.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mensah, P.F.; Stubblefield, M.A.; Pang, S.S.

    Thermal characterization of a prepreg fabric used as the bonding material to join composite pipes has been modeled and solved using finite difference modeling (FDM) numerical analysis technique for one dimensional heat transfer through the material. Temperature distributions within the composite pipe joint are predicted. The prepreg material has temperature dependent thermal properties. Thus the resulting boundary value equations are non linear and analytical solutions cannot be obtained. This characterization is pertinent in determining the temperature profile in the prepreg layer during the manufacturing process for optimization purposes. In addition, in order to assess the effects of induced thermal stressmore » in the joint, the temperature profile is needed. The methodology employed in this analysis compares favorably with data from experimentation.« less

  8. A 3D joint interpretation of magnetotelluric and seismic tomographic models: The case of the volcanic island of Tenerife

    NASA Astrophysics Data System (ADS)

    García-Yeguas, Araceli; Ledo, Juanjo; Piña-Varas, Perla; Prudencio, Janire; Queralt, Pilar; Marcuello, Alex; Ibañez, Jesús M.; Benjumea, Beatriz; Sánchez-Alzola, Alberto; Pérez, Nemesio

    2017-12-01

    In this work we have done a 3D joint interpretation of magnetotelluric and seismic tomography models. Previously we have described different techniques to infer the inner structure of the Earth. We have focused on volcanic regions, specifically on Tenerife Island volcano (Canary Islands, Spain). In this area, magnetotelluric and seismic tomography studies have been done separately. The novelty of the present work is the combination of both techniques in Tenerife Island. For this aim we have applied Fuzzy Clusters Method at different depths obtaining several clusters or classes. From the results, a geothermal system has been inferred below Teide volcano, in the center of Tenerife Island. An edifice hydrothermally altered and full of fluids is situated below Teide, ending at 600 m below sea level. From this depth the resistivity and VP values increase downwards. We also observe a clay cap structure, a typical feature in geothermal systems related with low resistivity and low VP values.

  9. [Clinical evaluation and psychological aspects of temporomandibular joint disorders].

    PubMed

    Coessens, P; De Boever, J A

    1997-01-01

    Establishing the patient's clinical diagnosis depends on gathering as much information of the patient and his or her signs and symptoms as possible. This information can be gathered from history, physical and psychological examination, diagnostic analysis. It is also important to look upon pain as a disorder and to consider the relationship between pain and psychological factors. The differential diagnosis is constructed through a biopsychological model of illness rather than through a more traditional biomedical model of disease. To arrive at a consistently accurate clinical diagnosis in patients with TMJ and craniofacial pain, the technique of clinical diagnosis must be well defined, reliable and include examination of the head and the neck, cranial nerves and the stomatognathic system. The craniomandibular index provides a standardized examination of the stomatognathic system that has been tested on validity and reliability. This chapter focuses on the techniques of history taking clinical and psychological examination and diagnostic criteria for temporomandibular joint disorders and muscle pain.

  10. Finite element based simulation on friction stud welding of metal matrix composites to steel

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Tharmaraj, R.; Velu, P. Shenbaga; Kumar, R.

    2016-05-01

    Friction welding is a solid state joining technique used for joining similar and dissimilar materials with high integrity. This new technique is being successfully applied to the aerospace, automobile, and ship building industries, and is attracting more and more research interest. The quality of Friction Stud Welded joints depends on the frictional heat generated at the interface. Hence, thermal analysis on friction stud welding of stainless steel (AISI 304) and aluminium silicon carbide (AlSiC) combination is carried out in the present work. In this study, numerical simulation is carried out using ANSYS software and the temperature profiles are predicted at various increments of time. The developed numerical model is found to be adequate to predict temperature distribution of friction stud weld aluminium silicon carbide/stainless steel joints.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    GLASS, S. JILL; LOEHMAN, RONALD E.; HOSKING, F. MICHAEL

    The main objective of this project was to develop reliable, low-cost techniques for joining silicon nitride (Si{sub 3}N{sub 4}) to itself and to metals. For Si{sub 3}N{sub 4} to be widely used in advanced turbomachinery applications, joining techniques must be developed that are reliable, cost-effective, and manufacturable. This project addressed those needs by developing and testing two Si{sub 3}N{sub 4} joining systems; oxynitride glass joining materials and high temperature braze alloys. Extensive measurements were also made of the mechanical properties and oxidation resistance of the braze materials. Finite element models were used to predict the magnitudes and positions of themore » stresses in the ceramic regions of ceramic-to-metal joints sleeve and butt joints, similar to the geometries used for stator assemblies.« less

  12. Consistent Alignment of World Embedding Models

    DTIC Science & Technology

    2017-03-02

    propose a solution that aligns variations of the same model (or different models) in a joint low-dimensional la- tent space leveraging carefully...representations of linguistic enti- ties, most often referred to as embeddings. This includes techniques that rely on matrix factoriza- tion (Levy & Goldberg ...higher, the variation is much higher as well. As we increase the size of the neighborhood, or improve the quality of our sample by only picking the most

  13. Label-free characterization of degenerative changes in articular cartilage by Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Oshima, Yusuke; Akehi, Mayu; Kiyomatsu, Hiroshi; Miura, Hiromasa

    2017-04-01

    Osteoarthritis (OA) is very common joint disease in the aging population. Main symptom of OA is accompanied by degenerative changes of articular cartilage. Raman spectroscopy is a label-free technique which enables to analyze molecular composition in degenerative cartilage. We generated an animal OA model surgically induced by knee joint instability and performed Raman spectroscopic analysis for the articular cartilage. In the result, Raman spectral data of the articular cartilage showed drastic changes in comparison between OA and control side. The relative intensity of phosphate band increases in the degenerative cartilage.

  14. Use of AMMI and linear regression models to analyze genotype-environment interaction in durum wheat.

    PubMed

    Nachit, M M; Nachit, G; Ketata, H; Gauch, H G; Zobel, R W

    1992-03-01

    The joint durum wheat (Triticum turgidum L var 'durum') breeding program of the International Maize and Wheat Improvement Center (CIMMYT) and the International Center for Agricultural Research in the Dry Areas (ICARDA) for the Mediterranean region employs extensive multilocation testing. Multilocation testing produces significant genotype-environment (GE) interaction that reduces the accuracy for estimating yield and selecting appropriate germ plasm. The sum of squares (SS) of GE interaction was partitioned by linear regression techniques into joint, genotypic, and environmental regressions, and by Additive Main effects and the Multiplicative Interactions (AMMI) model into five significant Interaction Principal Component Axes (IPCA). The AMMI model was more effective in partitioning the interaction SS than the linear regression technique. The SS contained in the AMMI model was 6 times higher than the SS for all three regressions. Postdictive assessment recommended the use of the first five IPCA axes, while predictive assessment AMMI1 (main effects plus IPCA1). After elimination of random variation, AMMI1 estimates for genotypic yields within sites were more precise than unadjusted means. This increased precision was equivalent to increasing the number of replications by a factor of 3.7.

  15. Fluoroscopy-Guided Sacroiliac Intraarticular Injection via the Middle Portion of the Joint.

    PubMed

    Kurosawa, Daisuke; Murakami, Eiichi; Aizawa, Toshimi

    2017-09-01

    Sacroiliac intraarticular injection is necessary to confirm sacroiliac joint (SIJ) pain and is usually performed via the caudal one-third portion of the joint. However, this is occasionally impossible for anatomical reasons, and the success rate is low in clinical settings. We describe a technique via the middle portion of the joint. Observational study. Enrolled were 69 consecutive patients (27 men and 42 women, with an average age of 53 years) in whom the middle portion of 100 joints was targeted. With the patient lying prone-oblique with the painful side down, a spinal needle was inserted into the middle portion of the joint. Subsequently, the fluoroscopy tube was angled at a caudal tilt of 25-30° to clearly detect the recess between the ilium and sacrum and the needle depth and direction. When the needle reached the posterior joint line, 2% lidocaine was injected after the contrast medium outlined the joint. The success rate of the injection method was 80% (80/100). Among 80 successful cases, four were previously unsuccessful when the conventional method was used. Intraarticular injection using the new technique was unsuccessful in 20 joints; in three of these cases, the conventional method proved successful, and no techniques were successful in the other 17 cases. The injection technique via the middle portion of the joint can overcome some of the difficulties of the conventional injection method and can improve the chances of successful intraarticular injection. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Long-Wavelength Elastic Wave Propagation Across Naturally Fractured Rock Masses

    NASA Astrophysics Data System (ADS)

    Mohd-Nordin, Mohd Mustaqim; Song, Ki-Il; Cho, Gye-Chun; Mohamed, Zainab

    2014-03-01

    Geophysical site investigation techniques based on elastic waves have been widely used to characterize rock masses. However, characterizing jointed rock masses by using such techniques remains challenging because of a lack of knowledge about elastic wave propagation in multi-jointed rock masses. In this paper, the roughness of naturally fractured rock joint surfaces is estimated by using a three-dimensional (3D) image-processing technique. The classification of the joint roughness coefficient (JRC) is enhanced by introducing the scan line technique. The peak-to-valley height is selected as a key indicator for JRC classification. Long-wavelength P-wave and torsional S-wave propagation across rock masses containing naturally fractured joints are simulated through the quasi-static resonant column (QSRC) test. In general, as the JRC increases, the S-wave velocity increases within the range of stress levels considered in this paper, whereas the P-wave velocity and the damping ratio of the shear wave decrease. In particular, the two-dimensional joint specimen underestimates the S-wave velocity while overestimating the P-wave velocity. This suggests that 3D joint surfaces should be implicated to obtain the reliable elastic wave velocity in jointed rock masses. The contact characteristic and degree of roughness and waviness of the joint surface are identified as a factor influencing P-wave and S-wave propagation in multi-jointed rock masses. The results indicate a need for a better understanding of the sensitivity of contact area alterations to the elastic wave velocity induced by changes in normal stress. This paper's framework can be a reference for future research on elastic wave propagation in naturally multi-jointed rock masses.

  17. Interrater and intrarater reliability in the measurement of ankle joint dorsiflexion is independent of examiner experience and technique used.

    PubMed

    Kim, Paul Jeong; Peace, Ruth; Mieras, Jamie; Thoms, Tanya; Freeman, Denise; Page, Jeffrey

    2011-01-01

    Goniometric measurement is currently being used as a diagnostic and outcomes assessment tool for ankle joint dorsiflexion. Despite its common use, its interrater and intrarater reliability has been questioned. This is a prospective study examining whether the experience of the examiner or the technique used affects the interrater and intrarater reliability for measuring ankle joint dorsiflexion. Fourteen asymptomatic individuals (8 male and 6 female) with a mean age of 28.2 years (range, 23-52) were enrolled into this study. The years of clinical experience of the five examiners averaged 10.4 years (range, 0-26). Four examiners used a modified Root, Weed and Orien method of measuring ankle joint dorsiflexion. The fifth examiner utilized a nonstandardized technique. A standard goniometer was used for bilateral measurements of ankle joint dorsiflexion with the knee extended and flexed. All five examiners repeated each measurement three times during each of the three sessions, with each session spaced at least 1 week apart. The interclass correlation coefficient reveals a moderate intrarater and poor interrater reliability in ankle joint dorsiflexion measurements using a standard goniometer. More importantly, further analysis indicates that the use of a standardized technique for measurement of ankle joint dorsiflexion or years of clinical experience does not increase the intrarater or interrater reliability. The utility of the goniometric measurement of ankle joint dorsiflexion may be limited.

  18. In Vivo Kinematics of the Tibiotalar and Subtalar Joints in Asymptomatic Subjects: A High-Speed Dual Fluoroscopy Study.

    PubMed

    Roach, Koren E; Wang, Bibo; Kapron, Ashley L; Fiorentino, Niccolo M; Saltzman, Charles L; Bo Foreman, K; Anderson, Andrew E

    2016-09-01

    Measurements of joint kinematics are essential to understand the pathomechanics of ankle disease and the effects of treatment. Traditional motion capture techniques do not provide measurements of independent tibiotalar and subtalar joint motion. In this study, high-speed dual fluoroscopy images of ten asymptomatic adults were acquired during treadmill walking at 0.5 m/s and 1.0 m/s and a single-leg, balanced heel-rise. Three-dimensional (3D) CT models of each bone and dual fluoroscopy images were used to quantify in vivo kinematics for the tibiotalar and subtalar joints. Dynamic tibiotalar and subtalar mean joint angles often exhibited opposing trends during captured stance. During both speeds of walking, the tibiotalar joint had significantly greater dorsi/plantarflexion (D/P) angular ROM than the subtalar joint while the subtalar joint demonstrated greater inversion/eversion (In/Ev) and internal/external rotation (IR/ER) than the tibiotalar joint. During balanced heel-rise, only D/P and In/Ev were significantly different between the tibiotalar and subtalar joints. Translational ROM in the anterior/posterior (AP) direction was significantly greater in the subtalar than the tibiotalar joint during walking at 0.5 m/s. Overall, our results support the long-held belief that the tibiotalar joint is primarily responsible for D/P, while the subtalar joint facilitates In/Ev and IR/ER. However, the subtalar joint provided considerable D/P rotation, and the tibiotalar joint rotated about all three axes, which, along with translational motion, suggests that each joint undergoes complex, 3D motion.

  19. Kartogenin treatment prevented joint degeneration in a rodent model of osteoarthritis: A pilot study.

    PubMed

    Mohan, Geetha; Magnitsky, Sergey; Melkus, Gerd; Subburaj, Karupppasamy; Kazakia, Galateia; Burghardt, Andrew J; Dang, Alexis; Lane, Nancy E; Majumdar, Sharmila

    2016-10-01

    Osteoarthritis (OA) is a major degenerative joint disease characterized by progressive loss of articular cartilage, synovitis, subchondral bone changes, and osteophyte formation. Currently there is no treatment for OA except temporary pain relief and end-stage joint replacement surgery. We performed a pilot study to determine the effect of kartogenin (KGN, a small molecule) on both cartilage and subchondral bone in a rat model of OA using multimodal imaging techniques. OA was induced in rats (OA and KGN treatment group) by anterior cruciate ligament transection (ACLT) surgery in the right knee joint. Sham surgery was performed on the right knee joint of control group rats. KGN group rats received weekly intra-articular injection of 125 μM KGN 1 week after surgery until week 12. All rats underwent in vivo magnetic resonance imaging (MRI) at 3, 6, and 12 weeks after surgery. Quantitative MR relaxation measures (T 1ρ and T 2 ) were determined to evaluate changes in articular cartilage. Cartilage and bone turnover markers (COMP and CTX-I) were determined at baseline, 3, 6, and 12 weeks. Animals were sacrificed at week 12 and the knee joints were removed for micro-computed tomography (micro-CT) and histology. KGN treatment significantly lowered the T 1ρ and T 2 relaxation times indicating decreased cartilage degradation. KGN treatment significantly decreased COMP and CTX-I levels indicating decreased cartilage and bone turnover rate. KGN treatment also prevented subchondral bone changes in the ACLT rat model of OA. Thus, kartogenin is a potential drug to prevent joint deterioration in post-traumatic OA. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1780-1789, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. Application of multivariate Gaussian detection theory to known non-Gaussian probability density functions

    NASA Astrophysics Data System (ADS)

    Schwartz, Craig R.; Thelen, Brian J.; Kenton, Arthur C.

    1995-06-01

    A statistical parametric multispectral sensor performance model was developed by ERIM to support mine field detection studies, multispectral sensor design/performance trade-off studies, and target detection algorithm development. The model assumes target detection algorithms and their performance models which are based on data assumed to obey multivariate Gaussian probability distribution functions (PDFs). The applicability of these algorithms and performance models can be generalized to data having non-Gaussian PDFs through the use of transforms which convert non-Gaussian data to Gaussian (or near-Gaussian) data. An example of one such transform is the Box-Cox power law transform. In practice, such a transform can be applied to non-Gaussian data prior to the introduction of a detection algorithm that is formally based on the assumption of multivariate Gaussian data. This paper presents an extension of these techniques to the case where the joint multivariate probability density function of the non-Gaussian input data is known, and where the joint estimate of the multivariate Gaussian statistics, under the Box-Cox transform, is desired. The jointly estimated multivariate Gaussian statistics can then be used to predict the performance of a target detection algorithm which has an associated Gaussian performance model.

  1. New technique of skin embedded wire double-sided laser beam welding

    NASA Astrophysics Data System (ADS)

    Han, Bing; Tao, Wang; Chen, Yanbin

    2017-06-01

    In the aircraft industry, double-sided laser beam welding is an approved method for producing skin-stringer T-joints on aircraft fuselage panels. As for the welding of new generation aluminum-lithium alloys, however, this technique is limited because of high hot cracking susceptibility and strengthening elements' uneven distributions within weld. In the present study, a new technique of skin embedded wire double-sided laser beam welding (LBW) has been developed to fabricate T-joints consisting of 2.0 mm thick 2060-T8/2099-T83 aluminum-lithium alloys using eutectic alloy AA4047 filler wire. Necessary dimension parameters of the novel groove were reasonably designed for achieving crack-free welds. Comparisons were made between the new technique welded T-joint and conventional T-joint mainly on microstructure, hot crack, elements distribution features and mechanical properties within weld. Excellent crack-free microstructure, uniform distribution of silicon and superior tensile properties within weld were found in the new skin embedded wire double-sided LBW T-joints.

  2. Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review

    PubMed Central

    Akhtar, Riaz; Comerford, Eithne J.; Bates, Karl T.

    2018-01-01

    Understanding how structural and functional alterations of individual tissues impact on whole-joint function is challenging, particularly in humans where direct invasive experimentation is difficult. Finite element (FE) computational models produce quantitative predictions of the mechanical and physiological behaviour of multiple tissues simultaneously, thereby providing a means to study changes that occur through healthy ageing and disease such as osteoarthritis (OA). As a result, significant research investment has been placed in developing such models of the human knee. Previous work has highlighted that model predictions are highly sensitive to the various inputs used to build them, particularly the mathematical definition of material properties of biological tissues. The goal of this systematic review is two-fold. First, we provide a comprehensive summation and evaluation of existing linear elastic material property data for human tibiofemoral joint tissues, tabulating numerical values as a reference resource for future studies. Second, we review efforts to model tibiofemoral joint mechanical behaviour through FE modelling with particular focus on how studies have sourced tissue material properties. The last decade has seen a renaissance in material testing fuelled by development of a variety of new engineering techniques that allow the mechanical behaviour of both soft and hard tissues to be characterised at a spectrum of scales from nano- to bulk tissue level. As a result, there now exists an extremely broad range of published values for human tibiofemoral joint tissues. However, our systematic review highlights gaps and ambiguities that mean quantitative understanding of how tissue material properties alter with age and OA is limited. It is therefore currently challenging to construct FE models of the knee that are truly representative of a specific age or disease-state. Consequently, recent tibiofemoral joint FE models have been highly generic in terms of material properties even relying on non-human data from multiple species. We highlight this by critically evaluating current ability to quantitatively compare and model (1) young and old and (2) healthy and OA human tibiofemoral joints. We suggest that future research into both healthy and diseased knee function will benefit greatly from a subject- or cohort-specific approach in which FE models are constructed using material properties, medical imagery and loading data from cohorts with consistent demographics and/or disease states. PMID:29379690

  3. Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review.

    PubMed

    Peters, Abby E; Akhtar, Riaz; Comerford, Eithne J; Bates, Karl T

    2018-01-01

    Understanding how structural and functional alterations of individual tissues impact on whole-joint function is challenging, particularly in humans where direct invasive experimentation is difficult. Finite element (FE) computational models produce quantitative predictions of the mechanical and physiological behaviour of multiple tissues simultaneously, thereby providing a means to study changes that occur through healthy ageing and disease such as osteoarthritis (OA). As a result, significant research investment has been placed in developing such models of the human knee. Previous work has highlighted that model predictions are highly sensitive to the various inputs used to build them, particularly the mathematical definition of material properties of biological tissues. The goal of this systematic review is two-fold. First, we provide a comprehensive summation and evaluation of existing linear elastic material property data for human tibiofemoral joint tissues, tabulating numerical values as a reference resource for future studies. Second, we review efforts to model tibiofemoral joint mechanical behaviour through FE modelling with particular focus on how studies have sourced tissue material properties. The last decade has seen a renaissance in material testing fuelled by development of a variety of new engineering techniques that allow the mechanical behaviour of both soft and hard tissues to be characterised at a spectrum of scales from nano- to bulk tissue level. As a result, there now exists an extremely broad range of published values for human tibiofemoral joint tissues. However, our systematic review highlights gaps and ambiguities that mean quantitative understanding of how tissue material properties alter with age and OA is limited. It is therefore currently challenging to construct FE models of the knee that are truly representative of a specific age or disease-state. Consequently, recent tibiofemoral joint FE models have been highly generic in terms of material properties even relying on non-human data from multiple species. We highlight this by critically evaluating current ability to quantitatively compare and model (1) young and old and (2) healthy and OA human tibiofemoral joints. We suggest that future research into both healthy and diseased knee function will benefit greatly from a subject- or cohort-specific approach in which FE models are constructed using material properties, medical imagery and loading data from cohorts with consistent demographics and/or disease states.

  4. An EMAT-based shear horizontal (SH) wave technique for adhesive bond inspection

    NASA Astrophysics Data System (ADS)

    Arun, K.; Dhayalan, R.; Balasubramaniam, Krishnan; Maxfield, Bruce; Peres, Patrick; Barnoncel, David

    2012-05-01

    The evaluation of adhesively bonded structures has been a challenge over the several decades that these structures have been used. Applications within the aerospace industry often call for particularly high performance adhesive bonds. Several techniques have been proposed for the detection of disbonds and cohesive weakness but a reliable NDE method for detecting interfacial weakness (also sometimes called a kissing bond) has been elusive. Different techniques, including ultrasonic, thermal imaging and shearographic methods, have been proposed; all have had some degree of success. In particular, ultrasonic methods, including those based upon shear and guided waves, have been explored for the assessment of interfacial bond quality. Since 3-D guided shear horizontal (SH) waves in plates have predominantly shear displacement at the plate surfaces, we conjectured that SH guided waves should be influenced by interfacial conditions when they propagate between adhesively bonded plates of comparable thickness. This paper describes a new technique based on SH guided waves that propagate within and through a lap joint. Through mechanisms we have yet to fully understand, the propagation of an SH wave through a lap joint gives rise to a reverberation signal that is due to one or more reflections of an SH guided wave mode within that lap joint. Based upon a combination of numerical simulations and measurements, this method shows promise for detecting and classifying interfacial bonds. It is also apparent from our measurements that the SH wave modes can discriminate between adhesive and cohesive bond weakness in both Aluminum-Epoxy-Aluminum and Composite-Epoxy-Composite lap joints. All measurements reported here used periodic permanent magnet (PPM) Electro-Magnetic Acoustic Transducers (EMATs) to generate either or both of the two lowest order SH modes in the plates that comprise the lap joint. This exact configuration has been simulated using finite element (FE) models to describe the SH mode generation, propagation and reception. Of particular interest is that one SH guided wave mode (probably SH0) reverberates within the lap joint. Moreover, in both simulations and measurements, features of this so-called reverberation signal appear to be related to interfacial weakness between the plate (substrate) and the epoxy bond. The results of a hybrid numerical (FE) approach based on using COMSOL to calculate the driving forces within an elastic solid and ABAQUS to propagate the resulting elastic disturbances (waves) within the plates and lap joint are compared with measurements of SH wave generation and reception in lap joint specimens having different interfacial and cohesive bonding conditions.

  5. Rheumatoid Arthritis Pain: Tips for Protecting Your Joints

    MedlinePlus

    Rheumatoid arthritis pain: Tips for protecting your joints Use these joint protection techniques to help you stay in control of your rheumatoid arthritis pain. By Mayo Clinic Staff Joint protection is ...

  6. A new technique for repair of a dislocated sternoclavicular joint using a sternal tension cable system.

    PubMed

    Janson, Jacques T; Rossouw, Gawie J

    2013-02-01

    An unstable anterior or posterior sternoclavicular joint dislocation can cause severe morbidity with poor shoulder movement and strength. These dislocations need to be repaired, which can be challenging. Many different procedures have been described to obtain a stable joint fixation with varying results. We report a new technique for repairing a sternoclavicular joint dislocation by using a figure-of-eight sternal cable system. This procedure is relatively simple and reproducible to create a stable and functional sternoclavicular joint. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Wilder, Michael C.

    2013-01-01

    For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

  8. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  9. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  10. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  11. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  12. 21 CFR 888.5 - Resurfacing technique.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... techniques, certain joint prostheses require far less bone resection than other devices intended to repair or replace the same joint. The amount of bone resection may or may not affect the safety and effectiveness of...

  13. Longitudinal Joint Construction Techniques for Asphalt Pavements

    DOT National Transportation Integrated Search

    1997-08-01

    Thirty hot mix asphalt (HMA) test sections were constructed in Michigan (1992), Wisconsin (1992), Colorado (1994), and Pennsylvania (1995) to evaluate the effectiveness of twelve different longitudinal joint construction techniques. The performance o...

  14. An evaluation of the lap-shear test for Sn-rich solder/Cu couples: Experiments and simulation

    NASA Astrophysics Data System (ADS)

    Chawla, N.; Shen, Y.-L.; Deng, X.; Ege, E. S.

    2004-12-01

    The lap-shear technique is commonly used to evaluate the shear, creep, and thermal fatigue behavior of solder joints. We have conducted a parametric experimental and modeling study, on the effect of testing and geometrical parameters on solder/copper joint response in lap-shear. It was shown that the farfield applied strain is quite different from the actual solder strain (measured optically). Subtraction of the deformation of the Cu substrate provides a reasonable approximation of the solder strain in the elastic regime, but not in the plastic regime. Solder joint thickness has a profound effect on joint response. The solder response moves progressively closer to “true” shear response with increasing joint thickness. Numerical modeling using finite-element analyses were performed to rationalize the experimental findings. The same lap-shear configuration was used in the simulation. The input response for solder was based on the experimental tensile test result on bulk specimens. The calculated shear response, using both the commonly adopted far-field measure and the actual shear strain in solder, was found to be consistent with the trends observed in the lap-shear experiments. The geometric features were further explored to provide physical insight into the problem. Deformation of the substrate was found to greatly influence the shear behavior of the solder.

  15. Upper limb joint forces and moments during underwater cyclical movements.

    PubMed

    Lauer, Jessy; Rouard, Annie Hélène; Vilas-Boas, João Paulo

    2016-10-03

    Sound inverse dynamics modeling is lacking in aquatic locomotion research because of the difficulty in measuring hydrodynamic forces in dynamic conditions. Here we report the successful implementation and validation of an innovative methodology crossing new computational fluid dynamics and inverse dynamics techniques to quantify upper limb joint forces and moments while moving in water. Upper limb kinematics of seven male swimmers sculling while ballasted with 4kg was recorded through underwater motion capture. Together with body scans, segment inertial properties, and hydrodynamic resistances computed from a unique dynamic mesh algorithm capable to handle large body deformations, these data were fed into an inverse dynamics model to solve for joint kinetics. Simulation validity was assessed by comparing the impulse produced by the arms, calculated by integrating vertical forces over a stroke period, to the net theoretical impulse of buoyancy and ballast forces. A resulting gap of 1.2±3.5% provided confidence in the results. Upper limb joint load was within 5% of swimmer׳s body weight, which tends to supports the use of low-load aquatic exercises to reduce joint stress. We expect this significant methodological improvement to pave the way towards deeper insights into the mechanics of aquatic movement and the establishment of practice guidelines in rehabilitation, fitness or swimming performance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Joint two dimensional inversion of gravity and magnetotelluric data using correspondence maps

    NASA Astrophysics Data System (ADS)

    Carrillo Lopez, J.; Gallardo, L. A.

    2016-12-01

    Inverse problems in Earth sciences are inherently non-unique. To improve models and reduce the number of solutions we need to provide extra information. In geological context, this information could be a priori information, for example, geological information, well log data, smoothness, or actually, information of measures of different kind of data. Joint inversion provides an approach to improve the solution and reduce the errors due to suppositions of each method. To do that, we need a link between two or more models. Some approaches have been explored successfully in recent years. For example, Gallardo and Meju (2003), Gallardo and Meju (2004, 2011), and Gallardo et. al. (2012) used the directions of properties to measure the similarity between models minimizing their cross gradients. In this work, we proposed a joint iterative inversion method that use spatial distribution of properties as a link. Correspondence maps could be better characterizing specific Earth systems due they consider the relation between properties. We implemented a code in Fortran to do a two dimensional inversion of magnetotelluric and gravity data, which are two of the standard methods in geophysical exploration. Synthetic tests show the advantages of joint inversion using correspondence maps against separate inversion. Finally, we applied this technique to magnetotelluric and gravity data in the geothermal zone located in Cerro Prieto, México.

  17. A joint source-channel distortion model for JPEG compressed images.

    PubMed

    Sabir, Muhammad F; Sheikh, Hamid Rahim; Heath, Robert W; Bovik, Alan C

    2006-06-01

    The need for efficient joint source-channel coding (JSCC) is growing as new multimedia services are introduced in commercial wireless communication systems. An important component of practical JSCC schemes is a distortion model that can predict the quality of compressed digital multimedia such as images and videos. The usual approach in the JSCC literature for quantifying the distortion due to quantization and channel errors is to estimate it for each image using the statistics of the image for a given signal-to-noise ratio (SNR). This is not an efficient approach in the design of real-time systems because of the computational complexity. A more useful and practical approach would be to design JSCC techniques that minimize average distortion for a large set of images based on some distortion model rather than carrying out per-image optimizations. However, models for estimating average distortion due to quantization and channel bit errors in a combined fashion for a large set of images are not available for practical image or video coding standards employing entropy coding and differential coding. This paper presents a statistical model for estimating the distortion introduced in progressive JPEG compressed images due to quantization and channel bit errors in a joint manner. Statistical modeling of important compression techniques such as Huffman coding, differential pulse-coding modulation, and run-length coding are included in the model. Examples show that the distortion in terms of peak signal-to-noise ratio (PSNR) can be predicted within a 2-dB maximum error over a variety of compression ratios and bit-error rates. To illustrate the utility of the proposed model, we present an unequal power allocation scheme as a simple application of our model. Results show that it gives a PSNR gain of around 6.5 dB at low SNRs, as compared to equal power allocation.

  18. The Dorsal 4-finger Technique: A Novel Method to Examine Metacarpophalangeal Joints in Patients with Rheumatoid Arthritis.

    PubMed

    Omair, Mohammed A; Akhavan, Pooneh; Naraghi, Ali; Mittoo, Shikha; Xiong, Juan; Weber, Deborah; Lin, Daming; Weber, Melissa; Keystone, Edward C

    2018-03-01

    To describe the dorsal 4-finger technique (DFFT) in examining metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA) and compare it to the traditional 2-finger technique (TFT) using ultrasound (US) as a gold standard. Four rheumatologists evaluated 180 MCP joints of 18 patients with RA. All patients underwent US for greyscale (GSUS) and power Doppler US (PDUS). Agreements between rheumatologists, the 2 techniques, and US were evaluated using Cohen κ and the first-order agreement coefficient (AC1) κ methods. The population comprised 17 females (94.4%) with a mean (SD) age and disease duration of 56.8 (14.4) and 21.8 (12.9) years, respectively. Eight patients (44.4%) were taking methotrexate monotherapy, while 10 patients (55.6%) were receiving biologics. US evaluation revealed 69 (38.3%) and 30 (16.7%) joints exhibited synovitis grade 2-3 by GSUS and PDUS, respectively. Effusion was documented in 30 joints (16.7%). The mean intraobserver agreement using the DFFT and TFT were 80.5% and 86%, respectively. The mean interobserver agreements using the DFFT and TFT were 84% and 74%, respectively. κ agreement with US findings was similar for both techniques in tender joints but was higher for the DFFT in nontender joints (0.33 vs 0.07, p = 0.015 for GSUS) and (0.48 vs 0.11, p = 0.002 for PDUS). The DFFT had a higher sensitivity in detecting ballottement by GSUS (0.47 vs 0.2, p < 0.001) and PDUS (0.60 vs 0.27, p < 0.001). The DFFT is a novel, reproducible, and reliable method to examine MCP joints, and it has a better correlation with US than the traditional TFT.

  19. Procedures and Compliance of a Video Modeling Applied Behavior Analysis Intervention for Brazilian Parents of Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Bagaiolo, Leila F.; Mari, Jair de J.; Bordini, Daniela; Ribeiro, Tatiane C.; Martone, Maria Carolina C.; Caetano, Sheila C.; Brunoni, Decio; Brentani, Helena; Paula, Cristiane S.

    2017-01-01

    Video modeling using applied behavior analysis techniques is one of the most promising and cost-effective ways to improve social skills for parents with autism spectrum disorder children. The main objectives were: (1) To elaborate/describe videos to improve eye contact and joint attention, and to decrease disruptive behaviors of autism spectrum…

  20. The use of joint mobilization to improve clinical outcomes in hand therapy: a systematic review of the literature.

    PubMed

    Heiser, Rick; O'Brien, Virginia H; Schwartz, Deborah A

    2013-01-01

    Systematic review. Joint mobilizations are used as an intervention for improving range of motion, decreasing pain and ultimately improving function in patients with a wide variety of upper extremity diagnoses. However, there are only a limited number of studies describing this treatment for conditions affecting the elbow, wrist, and hand. Furthermore, it is unclear as to the most effective joint mobilization technique utilized and the most beneficial functional outcomes gained. Examine the current evidence describing joint mobilizations for treatment of conditions of the elbow, wrist and hand, and offer informative practical clinical guidance. Twenty-two studies dated between 1980 and 2011 were included in the systematic review for analysis. The current evidence provides moderate support for the inclusion of joint mobilizations in the treatment of lateral epicondylalgia (LE). In particular, mobilization with movement as described by Mulligan is supported with evidence from nine randomized clinical trials as an effective technique for the treatment of pain. Other described techniques include those known as Kaltenborn, Cyriax physical therapy, and Maitland, but the evidence for these techniques is limited. There is also limited evidence for the joint mobilizations in the treatment of wrist and hand conditions. The current literature offers limited support for joint mobilizations of the wrist and hand, and moderate support for joint mobilizations of the elbow for LE. There is moderate support for mobilization with movement. . Copyright © 2013 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  1. Novel joint cupping clinical maneuver for ultrasonographic detection of knee joint effusions.

    PubMed

    Uryasev, Oleg; Joseph, Oliver C; McNamara, John P; Dallas, Apostolos P

    2013-11-01

    Knee effusions occur due to traumatic and atraumatic causes. Clinical diagnosis currently relies on several provocative techniques to demonstrate knee joint effusions. Portable bedside ultrasonography (US) is becoming an adjunct to diagnosis of effusions. We hypothesized that a US approach with a clinical joint cupping maneuver increases sensitivity in identifying effusions as compared to US alone. Using unembalmed cadaver knees, we injected fluid to create effusions up to 10 mL. Each effusion volume was measured in a lateral transverse location with respect to the patella. For each effusion we applied a joint cupping maneuver from an inferior approach, and re-measured the effusion. With increased volume of saline infusion, the mean depth of effusion on ultrasound imaging increased as well. Using a 2-mm cutoff, we visualized an effusion without the joint cupping maneuver at 2.5 mL and with the joint cupping technique at 1 mL. Mean effusion diameter increased on average 0.26 cm for the joint cupping maneuver as compared to without the maneuver. The effusion depth was statistically different at 2.5 and 7.5 mL (P < .05). Utilizing a joint cupping technique in combination with US is a valuable tool in assessing knee effusions, especially those of subclinical levels. Effusion measurements are complicated by uneven distribution of effusion fluid. A clinical joint cupping maneuver concentrates the fluid in one recess of the joint, increasing the likelihood of fluid detection using US. © 2013 Elsevier Inc. All rights reserved.

  2. Non-destructive testing techniques based on nonlinear methods for assessment of debonding in single lap joints

    NASA Astrophysics Data System (ADS)

    Scarselli, G.; Ciampa, F.; Ginzburg, D.; Meo, M.

    2015-04-01

    Nonlinear ultrasonic non-destructive evaluation (NDE) methods can be used for the identification of defects within adhesive bonds as they rely on the detection of nonlinear elastic features for the evaluation of the bond strength. In this paper the nonlinear content of the structural response of a single lap joint subjected to ultrasonic harmonic excitation is both numerically and experimentally evaluated to identify and characterize the defects within the bonded region. Different metallic samples with the same geometry were experimentally tested in order to characterize the debonding between two plates by using two surface bonded piezoelectric transducers in pitch-catch mode. The dynamic response of the damaged samples acquired by the single receiver sensor showed the presence of higher harmonics (2nd and 3rd) and subharmonics of the fundamental frequencies. These nonlinear elastic phenomena are clearly due to nonlinear effects induced by the poor adhesion between the two plates. A new constitutive model aimed at representing the nonlinear material response generated by the interaction of the ultrasonic waves with the adhesive joint is also presented. Such a model is implemented in an explicit FE software and uses a nonlinear user defined traction-displacement relationship implemented by means of a cohesive material user model interface. The developed model is verified for the different geometrical and material configurations. Good agreement between the experimental and numerical nonlinear response showed that this model can be used as a simple and useful tool for understanding the quality of the adhesive joint.

  3. JANNAF 35th Combustion Subcommittee Meeting. Volume 1

    NASA Technical Reports Server (NTRS)

    Fry, Ronald S. (Editor); Gannaway, Mary T. (Editor); Rognan, Melanie (Editor)

    1998-01-01

    Volume 1, the first of two volumes is a compilation of 63 unclassified/unlimited distribution technical papers presented at the 35th meeting of the Joint Army-Navy-NASA-Air Force (JANNAF) Combustion Subcommittee (CS) held jointly with the 17th Propulsion Systems Hazards Subcommittee (PSHS) and Airbreathing Propulsion Subcommittee (APS). The meeting was held on 7-11 December 1998 at Raytheon Systems Company and the Marriott Hotel, Tucson, AZ. Topics covered include solid gun propellant processing, ignition and combustion, charge concepts, barrel erosion and flash, gun interior ballistics, kinetics and molecular modeling, ETC gun modeling, simulation and diagnostics, and liquid gun propellant combustion; solid rocket motor propellant combustion, combustion instability fundamentals, motor instability, and measurement techniques; and liquid and hybrid rocket combustion.

  4. Identification of the contribution of the ankle and hip joints to multi-segmental balance control

    PubMed Central

    2013-01-01

    Background Human stance involves multiple segments, including the legs and trunk, and requires coordinated actions of both. A novel method was developed that reliably estimates the contribution of the left and right leg (i.e., the ankle and hip joints) to the balance control of individual subjects. Methods The method was evaluated using simulations of a double-inverted pendulum model and the applicability was demonstrated with an experiment with seven healthy and one Parkinsonian participant. Model simulations indicated that two perturbations are required to reliably estimate the dynamics of a double-inverted pendulum balance control system. In the experiment, two multisine perturbation signals were applied simultaneously. The balance control system dynamic behaviour of the participants was estimated by Frequency Response Functions (FRFs), which relate ankle and hip joint angles to joint torques, using a multivariate closed-loop system identification technique. Results In the model simulations, the FRFs were reliably estimated, also in the presence of realistic levels of noise. In the experiment, the participants responded consistently to the perturbations, indicated by low noise-to-signal ratios of the ankle angle (0.24), hip angle (0.28), ankle torque (0.07), and hip torque (0.33). The developed method could detect that the Parkinson patient controlled his balance asymmetrically, that is, the right ankle and hip joints produced more corrective torque. Conclusion The method allows for a reliable estimate of the multisegmental feedback mechanism that stabilizes stance, of individual participants and of separate legs. PMID:23433148

  5. Leakproof Swaged Joints in Thin-Wall Tubing

    NASA Technical Reports Server (NTRS)

    Stuckenberg, F. H.; Crockett, L. K.; Snyder, W. E.

    1986-01-01

    Tubular inserts reinforce joints, reducing incidence of leaks. In new swaging technique, tubular inserts placed inside ends of both tubes to be joined. Made from thicker-wall tubing with outside diameter that matches inside diameter of thin tubing swaged, inserts support tube ends at joint. They ensure more uniform contact between swage fitting and tubing. New swaging technique developed for Al/Ti/V-alloy hydraulic supply lines.

  6. The joint US/UK 1990 epoch world magnetic model

    NASA Technical Reports Server (NTRS)

    Quinn, John M.; Coleman, Rachel J.; Peck, Michael R.; Lauber, Stephen E.

    1991-01-01

    A detailed summary of the data used, analyses performed, modeling techniques employed, and results obtained in the course of the 1990 Epoch World Magnetic Modeling effort are given. Also, use and limitations of the GEOMAG algorithm are presented. Charts and tables related to the 1990 World Magnetic Model (WMM-90) for the Earth's main field and secular variation in Mercator and polar stereographic projections are presented along with useful tables of several magnetic field components and their secular variation on a 5-degree worldwide grid.

  7. Digital tomosynthesis rendering of joint margins for arthritis assessment

    NASA Astrophysics Data System (ADS)

    Duryea, Jeffrey W.; Neumann, Gesa; Yoshioka, Hiroshi; Dobbins, James T., III

    2004-05-01

    PURPOSE: Rheumatoid arthritis (RA) of the hand is a significant healthcare problem. Techniques to accurately quantity the structural changes from RA are crucial for the development and prescription of therapies. Analysis of radiographic joint space width (JSW) is widely used and has demonstrated promise. However, radiography presents a 2D view of the joint. In this study we performed tomosynthesis reconstructions of proximal interphalangeal (PIP), and metacarpophalangeal (MCP) joints to measure the 3D joint structure. METHODS: We performed a reader study using simulated radiographs of 12 MCP and 12 PIP joints from skeletal specimens imaged with micro-CT. The tomosynthesis technique provided images of reconstructed planes with 0.75 mm spacing, which were presented to 2 readers with a computer tool. The readers were instructed to delineate the joint surfaces on tomosynthetic slices where they could visualize the margins. We performed a quantitative analysis of 5 slices surrounding the central portion of each joint. Reader-determined JSW was compared to a gold standard. As a figure of merit we calculated the average root-mean square deviation (RMSD). RESULTS: RMSD was 0.22 mm for both joints. For the individual joints, RMSD was 0.18 mm (MCP), and 0.26 mm (PIP). The reduced performance for the smaller PIP joints suggests that a slice spacing less than 0.75 mm may be more appropriate. CONCLUSIONS: We have demonstrated the capability of limited 3D rendering of joint surfaces using digital tomosynthesis. This technique promises to provide an improved method to visualize the structural changes of RA.

  8. Assistive-as-needed strategy for upper-limb robotic systems: A preliminary evaluation of the impedance control architecture

    NASA Astrophysics Data System (ADS)

    Khairuddin, I. M.; Sidek, S. N.; Yusof, H. Md; Majeed, A. P. P. Abdul; Puzi, A. Ahmad; Mat Rosly, H.

    2018-04-01

    Rehabilitation is a necessary restoration process of recovering impaired joint motion and muscle strength. Recent trends of rehabilitation have also moved towards providing more participation of the patient in therapy rather than simple passive treatments as it has been demonstrated to be non-trivial in promoting neural plasticity meant to promote motor recovery process. This paper presents an assistive control strategy based on impedance control technique. Dynamic modelling of upper arm is obtained by utilising the Euler-Lagrange formulation. The proportional-derivative (PD), computed torque control (CTC) impedance based framework is applied to examine its effectiveness in performing joint-space control with objectives specified in rehabilitating the elbow joint along the sagittal plane. A feasibility study through simulation was carried out to investigate the efficacy of the proposed controller on acceleration-based impedance model. The results show that impedance controller is more suitable as it allows the cooperative effort of the patient.

  9. Optimization and analysis of large chemical kinetic mechanisms using the solution mapping method - Combustion of methane

    NASA Technical Reports Server (NTRS)

    Frenklach, Michael; Wang, Hai; Rabinowitz, Martin J.

    1992-01-01

    A method of systematic optimization, solution mapping, as applied to a large-scale dynamic model is presented. The basis of the technique is parameterization of model responses in terms of model parameters by simple algebraic expressions. These expressions are obtained by computer experiments arranged in a factorial design. The developed parameterized responses are then used in a joint multiparameter multidata-set optimization. A brief review of the mathematical background of the technique is given. The concept of active parameters is discussed. The technique is applied to determine an optimum set of parameters for a methane combustion mechanism. Five independent responses - comprising ignition delay times, pre-ignition methyl radical concentration profiles, and laminar premixed flame velocities - were optimized with respect to thirteen reaction rate parameters. The numerical predictions of the optimized model are compared to those computed with several recent literature mechanisms. The utility of the solution mapping technique in situations where the optimum is not unique is also demonstrated.

  10. Muscle optimization techniques impact the magnitude of calculated hip joint contact forces.

    PubMed

    Wesseling, Mariska; Derikx, Loes C; de Groote, Friedl; Bartels, Ward; Meyer, Christophe; Verdonschot, Nico; Jonkers, Ilse

    2015-03-01

    In musculoskeletal modelling, several optimization techniques are used to calculate muscle forces, which strongly influence resultant hip contact forces (HCF). The goal of this study was to calculate muscle forces using four different optimization techniques, i.e., two different static optimization techniques, computed muscle control (CMC) and the physiological inverse approach (PIA). We investigated their subsequent effects on HCFs during gait and sit to stand and found that at the first peak in gait at 15-20% of the gait cycle, CMC calculated the highest HCFs (median 3.9 times peak GRF (pGRF)). When comparing calculated HCFs to experimental HCFs reported in literature, the former were up to 238% larger. Both static optimization techniques produced lower HCFs (median 3.0 and 3.1 pGRF), while PIA included muscle dynamics without an excessive increase in HCF (median 3.2 pGRF). The increased HCFs in CMC were potentially caused by higher muscle forces resulting from co-contraction of agonists and antagonists around the hip. Alternatively, these higher HCFs may be caused by the slightly poorer tracking of the net joint moment by the muscle moments calculated by CMC. We conclude that the use of different optimization techniques affects calculated HCFs, and static optimization approached experimental values best. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Lower extremity joint kinetics and lumbar curvature during squat and stoop lifting

    PubMed Central

    Hwang, Seonhong; Kim, Youngeun; Kim, Youngho

    2009-01-01

    Background In this study, kinematics and kinetics of the lower extremity joint and the lumbar lordosis during two different symmetrical lifting techniques(squat and stoop) were examined using the three-dimensional motion analysis. Methods Twenty-six young male volunteers were selected for the subjects in this study. While they lifted boxes weighing 5, 10 and 15 kg by both squat and stoop lifting techniques, their motions were captured and analyzed using the 3D motion analysis system which was synchronized with two forceplates and the electromyographic system. Joint kinematics was determined by the forty-three reflective markers which were attached on the anatomical locations based on the VICON Plug-in-Gait marker placement protocol. Joint kinetics was analyzed by using the inverse dynamics. Paired t-test and Kruskal-Wallis test was used to compare the differences of variables between two techniques, and among three different weights. Correlation coefficient was calculated to explain the role of lower limb joint motion in relation to the lumbar lordosis. Results There were not significant differences in maximum lumbar joint moments between two techniques. The hip and ankle contributed the most part of the support moment during squat lifting, and the knee flexion moment played an important role in stoop lifting. The hip, ankle and lumbar joints generated power and only the knee joint absorbed power in the squat lifting. The knee and ankle joints absorbed power, the hip and lumbar joints generated power in the stoop lifting. The bi-articular antagonist muscles' co-contraction around the knee joint during the squat lifting and the eccentric co-contraction of the gastrocnemius and the biceps femoris were found important for maintaining the straight leg during the stoop lifting. At the time of lordotic curvature appearance in the squat lifting, there were significant correlations in all three lower extremity joint moments with the lumbar joint. Differently, only the hip moment had significant correlation with the lumbar joint in the stoop lifting. Conclusion In conclusion, the knee extension which is prominent kinematics during the squat lifting was produced by the contributions of the kinetic factors from the hip and ankle joints(extensor moment and power generation) and the lumbar extension which is prominent kinematics during the stoop lifting could be produced by the contributions of the knee joint kinetic factors(flexor moment, power absorption, bi-articular muscle function). PMID:19183507

  12. Lower extremity joint kinetics and lumbar curvature during squat and stoop lifting.

    PubMed

    Hwang, Seonhong; Kim, Youngeun; Kim, Youngho

    2009-02-02

    In this study, kinematics and kinetics of the lower extremity joint and the lumbar lordosis during two different symmetrical lifting techniques(squat and stoop) were examined using the three-dimensional motion analysis. Twenty-six young male volunteers were selected for the subjects in this study. While they lifted boxes weighing 5, 10 and 15 kg by both squat and stoop lifting techniques, their motions were captured and analyzed using the 3D motion analysis system which was synchronized with two forceplates and the electromyographic system. Joint kinematics was determined by the forty-three reflective markers which were attached on the anatomical locations based on the VICON Plug-in-Gait marker placement protocol. Joint kinetics was analyzed by using the inverse dynamics. Paired t-test and Kruskal-Wallis test was used to compare the differences of variables between two techniques, and among three different weights. Correlation coefficient was calculated to explain the role of lower limb joint motion in relation to the lumbar lordosis. There were not significant differences in maximum lumbar joint moments between two techniques. The hip and ankle contributed the most part of the support moment during squat lifting, and the knee flexion moment played an important role in stoop lifting. The hip, ankle and lumbar joints generated power and only the knee joint absorbed power in the squat lifting. The knee and ankle joints absorbed power, the hip and lumbar joints generated power in the stoop lifting. The bi-articular antagonist muscles' co-contraction around the knee joint during the squat lifting and the eccentric co-contraction of the gastrocnemius and the biceps femoris were found important for maintaining the straight leg during the stoop lifting. At the time of lordotic curvature appearance in the squat lifting, there were significant correlations in all three lower extremity joint moments with the lumbar joint. Differently, only the hip moment had significant correlation with the lumbar joint in the stoop lifting. In conclusion, the knee extension which is prominent kinematics during the squat lifting was produced by the contributions of the kinetic factors from the hip and ankle joints(extensor moment and power generation) and the lumbar extension which is prominent kinematics during the stoop lifting could be produced by the contributions of the knee joint kinetic factors(flexor moment, power absorption, bi-articular muscle function).

  13. A multivariate quadrature based moment method for LES based modeling of supersonic combustion

    NASA Astrophysics Data System (ADS)

    Donde, Pratik; Koo, Heeseok; Raman, Venkat

    2012-07-01

    The transported probability density function (PDF) approach is a powerful technique for large eddy simulation (LES) based modeling of scramjet combustors. In this approach, a high-dimensional transport equation for the joint composition-enthalpy PDF needs to be solved. Quadrature based approaches provide deterministic Eulerian methods for solving the joint-PDF transport equation. In this work, it is first demonstrated that the numerical errors associated with LES require special care in the development of PDF solution algorithms. The direct quadrature method of moments (DQMOM) is one quadrature-based approach developed for supersonic combustion modeling. This approach is shown to generate inconsistent evolution of the scalar moments. Further, gradient-based source terms that appear in the DQMOM transport equations are severely underpredicted in LES leading to artificial mixing of fuel and oxidizer. To overcome these numerical issues, a semi-discrete quadrature method of moments (SeQMOM) is formulated. The performance of the new technique is compared with the DQMOM approach in canonical flow configurations as well as a three-dimensional supersonic cavity stabilized flame configuration. The SeQMOM approach is shown to predict subfilter statistics accurately compared to the DQMOM approach.

  14. Persistence of bacterial DNA in orthopedic infections.

    PubMed

    Kaplan, Heidi B; Miranda, Justin A; Gogola, Gloria R; Gomez, Karen; Ambrose, Catherine G

    2018-06-01

    Polymerase chain reaction (PCR) has been proposed as a method to identify bacteria in clinical samples because it is more sensitive than culture techniques and can produce results rapidly. However, PCR can detect DNA from dead cells and thus cannot distinguish between live and dead cells in a tissue sample. Killed Staphylococcus aureus cells were implanted into the femurs and knee joints of rats to determine the length of time that DNA from dead cells is detectable in a living animal under conditions similar to common orthopedic infections. In the joint infection model studied here, the DNA from the dead planktonic bacteria was detected using PCR immediately after injection or 24 h later, but was undetectable 48 and 72 h after injection. In the biofilm implanted-device model studied, the DNA from these dead biofilm cells was detected by PCR immediately after implantation and at 24 h, but not at 48 or 72 h. Thus, our results indicate that DNA from dead cells does not persist in these animal model systems for more than 2 days, which should reduce concerns about possible false positive results using molecular DNA-based techniques for the detection of pathogens. Copyright © 2018. Published by Elsevier Inc.

  15. Bayesian component separation: The Planck experience

    NASA Astrophysics Data System (ADS)

    Wehus, Ingunn Kathrine; Eriksen, Hans Kristian

    2018-05-01

    Bayesian component separation techniques have played a central role in the data reduction process of Planck. The most important strength of this approach is its global nature, in which a parametric and physical model is fitted to the data. Such physical modeling allows the user to constrain very general data models, and jointly probe cosmological, astrophysical and instrumental parameters. This approach also supports statistically robust goodness-of-fit tests in terms of data-minus-model residual maps, which are essential for identifying residual systematic effects in the data. The main challenges are high code complexity and computational cost. Whether or not these costs are justified for a given experiment depends on its final uncertainty budget. We therefore predict that the importance of Bayesian component separation techniques is likely to increase with time for intensity mapping experiments, similar to what has happened in the CMB field, as observational techniques mature, and their overall sensitivity improves.

  16. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    PubMed

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  17. Design and research on the two-joint mating system of underwater vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, Zhong-lin; Wang, Li-quan

    2013-03-01

    In the 21st century, people have come to the era of ocean science and ocean economy. With the development of ocean science and technology and the thorough research on the ocean, underwater mating technique has been widely used in such fields as sunk ship salvage, deep ocean workstation, submarine lifesaving aid and military affairs. In this paper, researches are made home and abroad on mating technology. Two-joint mating system of underwater vehicle is designed including plane system, three-dimensional assembly system and control system in order to increase the capacity of adapting platform obliquity and adopting rotational skirt scheme. It is clear that the system fits the working space of underwater vehicle passageway and there is no interference phenomenon in assembly design. The finite element model of the system shell and the pressurization of the joint are established. The results of the finite element computing and the pressing test are accordant, and thus it can testify that the shell material meet the need of intension and joint pressurization is reliable. Modeling of the control system is accomplished, and simulation and analysis are made, which can provide directions for the controller design of mating system of underwater vehicles.

  18. Dynamic modeling and optimal joint torque coordination of advanced robotic systems

    NASA Astrophysics Data System (ADS)

    Kang, Hee-Jun

    The development is documented of an efficient dynamic modeling algorithm and the subsequent optimal joint input load coordination of advanced robotic systems for industrial application. A closed-form dynamic modeling algorithm for the general closed-chain robotic linkage systems is presented. The algorithm is based on the transfer of system dependence from a set of open chain Lagrangian coordinates to any desired system generalized coordinate set of the closed-chain. Three different techniques for evaluation of the kinematic closed chain constraints allow the representation of the dynamic modeling parameters in terms of system generalized coordinates and have no restriction with regard to kinematic redundancy. The total computational requirement of the closed-chain system model is largely dependent on the computation required for the dynamic model of an open kinematic chain. In order to improve computational efficiency, modification of an existing open-chain KIC based dynamic formulation is made by the introduction of the generalized augmented body concept. This algorithm allows a 44 pct. computational saving over the current optimized one (O(N4), 5995 when N = 6). As means of resolving redundancies in advanced robotic systems, local joint torque optimization is applied for effectively using actuator power while avoiding joint torque limits. The stability problem in local joint torque optimization schemes is eliminated by using fictitious dissipating forces which act in the necessary null space. The performance index representing the global torque norm is shown to be satisfactory. In addition, the resulting joint motion trajectory becomes conservative, after a transient stage, for repetitive cyclic end-effector trajectories. The effectiveness of the null space damping method is shown. The modular robot, which is built of well defined structural modules from a finite-size inventory and is controlled by one general computer system, is another class of evolving, highly versatile, advanced robotic systems. Therefore, finally, a module based dynamic modeling algorithm is presented for the dynamic coordination of such reconfigurable modular robotic systems. A user interactive module based manipulator analysis program (MBMAP) has been coded in C language running on 4D/70 Silicon Graphics.

  19. Upper limb joint kinetics of three sitting pivot wheelchair transfer techniques in individuals with spinal cord injury.

    PubMed

    Kankipati, Padmaja; Boninger, Michael L; Gagnon, Dany; Cooper, Rory A; Koontz, Alicia M

    2015-07-01

    Repeated measures design. This study compared the upper extremity (UE) joint kinetics between three transfer techniques. Research laboratory. Twenty individuals with spinal cord injury performed three transfer techniques from their wheelchair to a level tub bench. Two of the techniques involved a head-hips method with leading hand position close (HH-I) and far (HH-A) from the body, and the third technique with the trunk upright (TU) and hand far from body. Motion analysis equipment recorded upper body movements and force sensors recorded their hand and feet reaction forces during the transfers. Several significant differences were found between HH-A and HH-I and TU and HH-I transfers indicating that hand placement was a key factor influencing the UE joint kinetics. Peak resultant hand, elbow, and shoulder joint forces were significantly higher for the HH-A and TU techniques at the trailing arm (P < 0.036) and lower at the leading arm (P < 0.021), compared to the HH-I technique. Always trailing with the same arm if using HH-A or TU could predispose that arm to overuse related pain and injuries. Technique training should focus on initial hand placement close to the body followed by the amount of trunk flexion needed to facilitate movement.

  20. A modified surgical technique for reconstruction of an acute acromioclavicular joint dislocation

    PubMed Central

    Marchie, Anthony; Kumar, Arun; Catre, Melanio

    2009-01-01

    We report a modified surgical technique for reconstruction of coracoclavicular and acromioclavicular ligaments after acute dislocation of acromioclavicular joint using suture anchors. We have repaired 3 consecutive type III acromioclavicular dislocations with good results. This technique is simple and safe and allows anatomical reconstruction of the ligaments in acute dislocations. PMID:20671868

  1. Inferior olive mirrors joint dynamics to implement an inverse controller.

    PubMed

    Alvarez-Icaza, Rodrigo; Boahen, Kwabena

    2012-10-01

    To produce smooth and coordinated motion, our nervous systems need to generate precisely timed muscle activation patterns that, due to axonal conduction delay, must be generated in a predictive and feedforward manner. Kawato proposed that the cerebellum accomplishes this by acting as an inverse controller that modulates descending motor commands to predictively drive the spinal cord such that the musculoskeletal dynamics are canceled out. This and other cerebellar theories do not, however, account for the rich biophysical properties expressed by the olivocerebellar complex's various cell types, making these theories difficult to verify experimentally. Here we propose that a multizonal microcomplex's (MZMC) inferior olivary neurons use their subthreshold oscillations to mirror a musculoskeletal joint's underdamped dynamics, thereby achieving inverse control. We used control theory to map a joint's inverse model onto an MZMC's biophysics, and we used biophysical modeling to confirm that inferior olivary neurons can express the dynamics required to mirror biomechanical joints. We then combined both techniques to predict how experimentally injecting current into the inferior olive would affect overall motor output performance. We found that this experimental manipulation unmasked a joint's natural dynamics, as observed by motor output ringing at the joint's natural frequency, with amplitude proportional to the amount of current. These results support the proposal that the cerebellum-in particular an MZMC-is an inverse controller; the results also provide a biophysical implementation for this controller and allow one to make an experimentally testable prediction.

  2. Optimizing Marine Corps Pilot Conversion to the Joint Strike Fighter

    DTIC Science & Technology

    2010-06-01

    Office of Civilian Manpower Management. Included are a summary of modeling efforts and the mathematics behind them, models for aggregate manpower...Vajda for the Admiralty of the Royal Navy. They also mention work by one of the first actuaries , John Rowe, who as early as 1779, conducted studies...idea of using mathematical and statistical techniques to obtain better information on the manpower requirements has its roots in personnel research

  3. Ultrasonic measurement and monitoring of loads in bolts used in structural joints

    NASA Astrophysics Data System (ADS)

    Koshti, Ajay M.

    2015-04-01

    The paper is an overview of work by the author in measuring and monitoring loads in bolts using an ultrasonic extensometer. A number of cases of bolted joints are covered. These include, a clamped joint with clearance fit between the bolt and hole, a clamped joint with bolt in an interference fit with the hole, a flanged joint which allows the flange and bolt to bend; and a shear joint in a clevis and tang configuration. These applications were initially developed for measuring and monitoring preload in National Aeronautics and Space Administration (NASA) Space Shuttle Orbiter critical joints but are also applicable for monitoring loads in other critical bolted joints of structures such as transportation bridges and other aerospace structures. The papers cited here explain how to set-up a model to estimate the ultrasonic load factor and accuracy for the ultrasonic preload application in a clamped joint with clearance fit. The ultrasonic preload application for clamped joint with bolt in an interference fit can also be used to measure diametrical interference between the bolt shank and hole, as well as interference pressure on the bolt shank. Results of simulation and experimental data are given to demonstrate use of ultrasonic measurements in a shear joint. A bolt in a flanged joint experiences both tensile and bending loads. This application involves measurement of bending and tensile preload in a bolt. The ultrasonic beam bends due to bending load on the bolt. Results of a numerical technique to compute the trace of ultrasonic ray are presented.

  4. Probabilistic image modeling with an extended chain graph for human activity recognition and image segmentation.

    PubMed

    Zhang, Lei; Zeng, Zhi; Ji, Qiang

    2011-09-01

    Chain graph (CG) is a hybrid probabilistic graphical model (PGM) capable of modeling heterogeneous relationships among random variables. So far, however, its application in image and video analysis is very limited due to lack of principled learning and inference methods for a CG of general topology. To overcome this limitation, we introduce methods to extend the conventional chain-like CG model to CG model with more general topology and the associated methods for learning and inference in such a general CG model. Specifically, we propose techniques to systematically construct a generally structured CG, to parameterize this model, to derive its joint probability distribution, to perform joint parameter learning, and to perform probabilistic inference in this model. To demonstrate the utility of such an extended CG, we apply it to two challenging image and video analysis problems: human activity recognition and image segmentation. The experimental results show improved performance of the extended CG model over the conventional directed or undirected PGMs. This study demonstrates the promise of the extended CG for effective modeling and inference of complex real-world problems.

  5. Gas Shielding Technology for Welding and Brazing

    NASA Technical Reports Server (NTRS)

    Nunes, Arthur J.; Gradl, Paul R.

    2012-01-01

    Welding is a common method that allows two metallic materials to be joined together with high structural integrity. When joints need to be leak-tight, light-weight, or free of contaminant-trapping seams or surface asperities, welding tends to be specified. There are many welding techniques, each with its own advantages and disadvantages. Some of these techniques include Forge Welding, Gas Tungsten Arc Welding, Friction Stir Welding, and Laser Beam Welding to name a few. Whichever technique is used, the objective is a structural joint that meets the requirements of a particular component or assembly. A key practice in producing quality welds is the use of shielding gas. This article discusses various weld techniques, quality of the welds, and importance of shielding gas in each of those techniques. Metallic bonds, or joints, are produced when metals are put into intimate contact. In the solid-state "blacksmith welding" process, now called Forge Welding (FOW), the site to be joined is pounded into intimate contact. The surfaces to be joined usually need to be heated to make it easier to deform the metal. The surfaces are sprinkled with a flux to melt surface oxides and given a concave shape so that surface contamination can be squeezed out of the joint as the surfaces are pounded together; otherwise the surface contamination would be trapped in the joint and would weaken the weld. In solid-state welding processes surface oxides or other contamination are typically squeezed out of the joint in "flash."

  6. Detection of micro gap weld joint by using magneto-optical imaging and Kalman filtering compensated with RBF neural network

    NASA Astrophysics Data System (ADS)

    Gao, Xiangdong; Chen, Yuquan; You, Deyong; Xiao, Zhenlin; Chen, Xiaohui

    2017-02-01

    An approach for seam tracking of micro gap weld whose width is less than 0.1 mm based on magneto optical (MO) imaging technique during butt-joint laser welding of steel plates is investigated. Kalman filtering(KF) technology with radial basis function(RBF) neural network for weld detection by an MO sensor was applied to track the weld center position. Because the laser welding system process noises and the MO sensor measurement noises were colored noises, the estimation accuracy of traditional KF for seam tracking was degraded by the system model with extreme nonlinearities and could not be solved by the linear state-space model. Also, the statistics characteristics of noises could not be accurately obtained in actual welding. Thus, a RBF neural network was applied to the KF technique to compensate for the weld tracking errors. The neural network can restrain divergence filter and improve the system robustness. In comparison of traditional KF algorithm, the RBF with KF was not only more effectively in improving the weld tracking accuracy but also reduced noise disturbance. Experimental results showed that magneto optical imaging technique could be applied to detect micro gap weld accurately, which provides a novel approach for micro gap seam tracking.

  7. Thermographic Analysis of Stress Distribution in Welded Joints

    NASA Astrophysics Data System (ADS)

    Piršić, T.; Krstulović Opara, L.; Domazet, Ž.

    2010-06-01

    The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural) stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis) in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  8. The efficacy of manual joint mobilisation/manipulation in treatment of lateral ankle sprains: a systematic review.

    PubMed

    Loudon, Janice K; Reiman, Michael P; Sylvain, Jonathan

    2014-03-01

    Lateral ankle sprains are common and can have detrimental consequences to the athlete. Joint mobilisation/manipulation may limit these outcomes. Systematically summarise the effectiveness of manual joint techniques in treatment of lateral ankle sprains. This review employed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A computer-assisted literature search of MEDLINE, CINHAL, EMBASE, OVID and Physiotherapy Evidence Database (PEDro) (January 1966 to March 2013) was used with the following keywords alone and in combination 'ankle', 'sprain', 'injuries', 'lateral', 'manual therapy', and 'joint mobilisation'. The methodological quality of individual studies was assessed using the PEDro scale. After screening of titles, abstracts and full articles, eight articles were kept for examination. Three articles achieved a score of 10 of 11 total points; one achieved a score of 9; two articles scored 8; one article scored a 7 and the remaining article scored a 5. Three articles examined joint techniques for acute sprains and the remainder examined subacute/chronic ankle sprains. Outcome measures included were pain level, ankle range of motion, swelling, functional score, stabilometry and gait parameters. The majority of the articles only assessed these outcome measures immediately after treatment. No detrimental effects from the joint techniques were revealed in any of the studies reviewed. For acute ankle sprains, manual joint mobilisation diminished pain and increased dorsiflexion range of motion. For treatment of subacute/chronic lateral ankle sprains, these techniques improved ankle range-of-motion, decreased pain and improved function.

  9. Weakly supervised automatic segmentation and 3D modeling of the knee joint from MR images

    NASA Astrophysics Data System (ADS)

    Amami, Amal; Ben Azouz, Zouhour

    2013-12-01

    Automatic segmentation and 3D modeling of the knee joint from MR images, is a challenging task. Most of the existing techniques require the tedious manual segmentation of a training set of MRIs. We present an approach that necessitates the manual segmentation of one MR image. It is based on a volumetric active appearance model. First, a dense tetrahedral mesh is automatically created on a reference MR image that is arbitrary selected. Second, a pairwise non-rigid registration between each MRI from a training set and the reference MRI is computed. The non-rigid registration is based on a piece-wise affine deformation using the created tetrahedral mesh. The minimum description length is then used to bring all the MR images into a correspondence. An average image and tetrahedral mesh, as well as a set of main modes of variations, are generated using the established correspondence. Any manual segmentation of the average MRI can be mapped to other MR images using the AAM. The proposed approach has the advantage of simultaneously generating 3D reconstructions of the surface as well as a 3D solid model of the knee joint. The generated surfaces and tetrahedral meshes present the interesting property of fulfilling a correspondence between different MR images. This paper shows preliminary results of the proposed approach. It demonstrates the automatic segmentation and 3D reconstruction of a knee joint obtained by mapping a manual segmentation of a reference image.

  10. Optimum design of bolted composite lap joints under mechanical and thermal loading

    NASA Astrophysics Data System (ADS)

    Kradinov, Vladimir Yurievich

    A new approach is developed for the analysis and design of mechanically fastened composite lap joints under mechanical and thermal loading. Based on the combined complex potential and variational formulation, the solution method satisfies the equilibrium equations exactly while the boundary conditions are satisfied by minimizing the total potential. This approach is capable of modeling finite laminate planform dimensions, uniform and variable laminate thickness, laminate lay-up, interaction among bolts, bolt torque, bolt flexibility, bolt size, bolt-hole clearance and interference, insert dimensions and insert material properties. Comparing to the finite element analysis, the robustness of the method does not decrease when modeling the interaction of many bolts; also, the method is more suitable for parametric study and design optimization. The Genetic Algorithm (GA), a powerful optimization technique for multiple extrema functions in multiple dimensions search spaces, is applied in conjunction with the complex potential and variational formulation to achieve optimum designs of bolted composite lap joints. The objective of the optimization is to acquire such a design that ensures the highest strength of the joint. The fitness function for the GA optimization is based on the average stress failure criterion predicting net-section, shear-out, and bearing failure modes in bolted lap joints. The criterion accounts for the stress distribution in the thickness direction at the bolt location by applying an approach utilizing a beam on an elastic foundation formulation.

  11. Stochastic methods for analysis of power flow in electric networks

    NASA Astrophysics Data System (ADS)

    1982-09-01

    The modeling and effects of probabilistic behavior on steady state power system operation were analyzed. A solution to the steady state network flow equations which adhere both to Kirchoff's Laws and probabilistic laws, using either combinatorial or functional approximation techniques was obtained. The development of sound techniques for producing meaningful data to serve as input is examined. Electric demand modeling, equipment failure analysis, and algorithm development are investigated. Two major development areas are described: a decomposition of stochastic processes which gives stationarity, ergodicity, and even normality; and a powerful surrogate probability approach using proportions of time which allows the calculation of joint events from one dimensional probability spaces.

  12. Dynamic Relaxation: A Technique for Detailed Thermo-Elastic Structural Analysis of Transportation Structures

    NASA Astrophysics Data System (ADS)

    Shoukry, Samir N.; William, Gergis W.; Riad, Mourad Y.; McBride, Kevyn C.

    2006-08-01

    Dynamic relaxation is a technique developed to solve static problems through an explicit integration in finite element. The main advantage of such a technique is the ability to solve a large problem in a relatively short time compared with the traditional implicit techniques, especially when using nonlinear material models. This paper describes the use of such a technique in analyzing large transportation structures as dowel jointed concrete pavements and 306-m-long, reinforced concrete bridge superstructure under the effect of temperature variations. The main feature of the pavement model is the detailed modeling of dowel bars and their interfaces with the surrounding concrete using extremely fine mesh of solid elements, while in the bridge structure it is the detailed modeling of the girder-deck interface as well as the bracing members between the girders. The 3DFE results were found to be in a good agreement with experimentally measured data obtained from an instrumented pavements sections and a highway bridge constructed in West Virginia. Thus, such a technique provides a good tool for analyzing the response of large structures to static loads in a fraction of the time required by traditional, implicit finite element methods.

  13. Energy flow during Olympic weight lifting.

    PubMed

    Garhammer, J

    1982-01-01

    Data obtained from 16-mm film of world caliber Olympic weight lifters performing at major competitions were analyzed to study energy changes during body segment and barbell movements, energy transfer to the barbell, and energy transfer between segments during the lifting movements contested. Determination of barbell and body segment kinematics and use of rigid-link modeling and energy flow techniques permitted the calculation of segment energy content and energy transfer between segments. Energy generation within and transfer to and from segments were determined at 0.04-s intervals by comparing mechanical energy changes of a segment with energy transfer at the joints, calculated from the scalar product of net joint force with absolute joint velocity, and the product of net joint torque due to muscular activity with absolute segment angular velocity. The results provided a detailed understanding of the magnitude and temporal input of energy from dominant muscle groups during a lift. This information also provided a means of quantifying lifting technique. Comparison of segment energy changes determined by the two methods were satisfactory but could likely be improved by employing more sophisticated data smoothing methods. The procedures used in this study could easily be applied to weight training and rehabilitative exercises to help determine their efficacy in producing desired results or to ergonomic situations where a more detailed understanding of the demands made on the body during lifting tasks would be useful.

  14. Shear Behaviour and Acoustic Emission Characteristics of Bolted Rock Joints with Different Roughnesses

    NASA Astrophysics Data System (ADS)

    Wang, Gang; Zhang, Yongzheng; Jiang, Yujing; Liu, Peixun; Guo, Yanshuang; Liu, Jiankang; Ma, Ming; Wang, Ke; Wang, Shugang

    2018-06-01

    To study shear failure, acoustic emission counts and characteristics of bolted jointed rock-like specimens are evaluated under compressive shear loading. Model joint surfaces with different roughnesses are made of rock-like material (i.e. cement). The jointed rock masses are anchored with bolts with different elongation rates. The characteristics of the shear mechanical properties, the failure mechanism, and the acoustic emission parameters of the anchored joints are studied under different surface roughnesses and anchorage conditions. The shear strength and residual strength increase with the roughness of the anchored joint surface. With an increase in bolt elongation, the shear strength of the anchored joint surface gradually decreases. When the anchored structural plane is sheared, the ideal cumulative impact curve can be divided into four stages: initial emission, critical instability, cumulative energy, and failure. With an increase in the roughness of the anchored joint surface, the peak energy rate and the cumulative number of events will also increase during macro-scale shear failure. With an increase in the bolt elongation, the energy rate and the event number increase during the shearing process. Furthermore, the peak energy rate, peak number of events and cumulative energy will all increase with the bolt elongation. The results of this study can provide guidance for the use of the acoustic emission technique in monitoring and predicting the static shear failure of anchored rock masses.

  15. Preshaping command inputs to reduce telerobotic system oscillations

    NASA Technical Reports Server (NTRS)

    Singer, Neil C.; Seering, Warren P.

    1989-01-01

    The results of using a new technique for shaping inputs to a model of the space shuttle Remote Manipulator System (RMS) are presented. The shapes inputs move the system to the same location that was originally commanded, however, the oscillations of the machine are considerably reduced. An overview of the new shaping method is presented. A description of RMS model is provided. The problem of slow joint servo rates on the RMS is accommodated with an extension of the shaping method. The results and sample data are also presented for both joint and three-dimensional cartesian motions. The results demonstrate that the new shaping method performs well on large, telerobotic systems which exhibit significant structural vibration. The new method is shown to also result in considerable energy savings during operations of the RMS manipulator.

  16. Longitudinal joint study.

    DOT National Transportation Integrated Search

    2001-09-01

    In previous years there has been a problem with longitudinal joint : deterioration, due in part to poor construction techniques. : The degradation of the longitudinal joints has increased the cost of : maintaining these projects and caused unnecessar...

  17. Inferior or double joint spaces injection versus superior joint space injection for temporomandibular disorders: a systematic review and meta-analysis.

    PubMed

    Li, Chunjie; Zhang, Yifan; Lv, Jun; Shi, Zongdao

    2012-01-01

    To compare the effect and safety of inferior or double temporomandibular joint spaces drug injection versus superior temporomandibular joint space injection in the treatment of temporomandibular disorders. MEDLINE (via Ovid, 1948 to March 2011), CENTRAL (Issue 1, 2011), Embase (1984 to March 2011), CBM (1978 to March 2011), and World Health Organization International Clinical Trials Registry Platform were searched electronically; relevant journals as well as references of included studies were hand-searched for randomized controlled trials comparing effect or safety of inferior or double joint spaces drug injection technique with those of superior space injection technique. Risk of bias assessment with the tool recommended by Cochrane Collaboration, reporting quality assessment with CONSORT and data extraction, were carried out independently by 2 reviewers. Meta-analysis was delivered with RevMan 5.0.23. Four trials with 349 participants were included. All the included studies had moderate risk of bias. Meta-analysis showed that inferior or double spaces injection technique could significantly increase 2.88 mm more maximal mouth opening (P = .0001) and alleviate pain intensity in the temporomandibular area on average by 9.01 mm visual analog scale scores (P = .0001) compared with superior space injection technique, but could not markedly change synthesized clinical index (P = .05) in the short term; nevertheless, they showed more beneficial maximal mouth opening (P = .002), pain relief (P < .0001), and synthesized clinical variable (P < .0001) in the long term than superior space injection. No serious adverse events were reported. Inferior or double temporomandibular joint spaces drug injection technique shows better effect than superior space injection technique, and their safety is affirmative. However, more high-quality studies are still needed to test and verify the evidence. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  18. Effect of joint mobilization techniques for primary total knee arthroplasty: Study protocol for a randomized controlled trial.

    PubMed

    Xu, Jiao; Zhang, Juan; Wang, Xue-Qiang; Wang, Xuan-Lin; Wu, Ya; Chen, Chan-Cheng; Zhang, Han-Yu; Zhang, Zhi-Wan; Fan, Kai-Yi; Zhu, Qiang; Deng, Zhi-Wei

    2017-12-01

    Total knee arthroplasty (TKA) has become the most preferred procedure by patients for the relief of pain caused by knee osteoarthritis. TKA patients aim a speedy recovery after the surgery. Joint mobilization techniques for rehabilitation have been widely used to relieve pain and improve joint mobility. However, relevant randomized controlled trials showing the curative effect of these techniques remain lacking to date. Accordingly, this study aims to investigate whether joint mobilization techniques are valid for primary TKA. We will manage a single-blind, prospective, randomized, controlled trial of 120 patients with unilateral TKA. Patients will be randomized into an intervention group, a physical modality therapy group, and a usual care group. The intervention group will undergo joint mobilization manipulation treatment once a day and regular training twice a day for a month. The physical modality therapy group will undergo physical therapy once a day and regular training twice a day for a month. The usual care group will perform regular training twice a day for a month. Primary outcome measures will be based on the visual analog scale, the knee joint Hospital for Special Surgery score, range of motion, surrounded degree, and adverse effect. Secondary indicators will include manual muscle testing, 36-Item Short Form Health Survey, Berg Balance Scale function evaluation, Pittsburgh Sleep Quality Index, proprioception, and muscle morphology. We will direct intention-to-treat analysis if a subject withdraws from the trial. The important features of this trial for joint mobilization techniques in primary TKA are randomization procedures, single-blind, large sample size, and standardized protocol. This study aims to investigate whether joint mobilization techniques are effective for early TKA patients. The result of this study may serve as a guide for TKA patients, medical personnel, and healthcare decision makers. It has been registered at http://www.chictr.org.cn/showproj.aspx?proj=15262 (Identifier:ChiCTR-IOR-16009192), Registered 11 September 2016. We also could provide the correct URL of the online registry in the WHO Trial Registration. http://apps.who.int/trialsearch/Trial2.aspx?TrialID=ChiCTR-IOR-16009192.

  19. Knee joint mobilization reduces secondary mechanical hyperalgesia induced by capsaicin injection into the ankle joint.

    PubMed

    Sluka, K A; Wright, A

    2001-01-01

    Joint mobilization is a treatment approach commonly used by physical therapists for the management of a variety of painful conditions. However, the clinical effectiveness when compared to placebo and the neurophysiological mechanism of action are not known. The purpose of this study was to establish that application of a manual therapy technique will produce antihyperalgesia in an animal model of joint inflammation and that the antihyperalgesia produced by joint mobilization depends on the time of treatment application. Capsaicin (0.2%, 50 microl) was injected into the lateral aspect of the left ankle joint and mechanical withdrawal threshold assessed before and after capsaicin injection in Sprague-Dawley rats. Joint mobilization of the ipsilateral knee joint was performed 2 h after capsaicin injection for a total of 3 min, 9 min or 15 min under halothane anaesthesia. Control groups included animals that received halothane for the same time as the group that received joint mobilization and those whose limbs were held for the same duration as the mobilization (no halothane). Capsaicin resulted in a decreased mechanical withdrawal threshold by 2 h after injection that was maintained through 4 h. Both 9 and 15 min of mobilization, but not 3 min of mobilization, increased the withdrawal threshold to mechanical stimuli to baseline values when compared with control groups. The antihyperalgesic effect of joint mobilization lasted 30 min. Thus, joint mobilization (9 or 15 min duration) produces a significant reversal of secondary mechanical hyperalgesia induced by intra-articular injection of capsaicin. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  20. Simulation Based Optimization of Complex Monolithic Composite Structures Using Cellular Core Technology

    NASA Astrophysics Data System (ADS)

    Hickmott, Curtis W.

    Cellular core tooling is a new technology which has the capability to manufacture complex integrated monolithic composite structures. This novel tooling method utilizes thermoplastic cellular cores as inner tooling. The semi-rigid nature of the cellular cores makes them convenient for lay-up, and under autoclave temperature and pressure they soften and expand providing uniform compaction on all surfaces including internal features such as ribs and spar tubes. This process has the capability of developing fully optimized aerospace structures by reducing or eliminating assembly using fasteners or bonded joints. The technology is studied in the context of evaluating its capabilities, advantages, and limitations in developing high quality structures. The complex nature of these parts has led to development of a model using the Finite Element Analysis (FEA) software Abaqus and the plug-in COMPRO Common Component Architecture (CCA) provided by Convergent Manufacturing Technologies. This model utilizes a "virtual autoclave" technique to simulate temperature profiles, resin flow paths, and ultimately deformation from residual stress. A model has been developed simulating the temperature profile during curing of composite parts made with the cellular core technology. While modeling of composites has been performed in the past, this project will look to take this existing knowledge and apply it to this new manufacturing method capable of building more complex parts and develop a model designed specifically for building large, complex components with a high degree of accuracy. The model development has been carried out in conjunction with experimental validation. A double box beam structure was chosen for analysis to determine the effects of the technology on internal ribs and joints. Double box beams were manufactured and sectioned into T-joints for characterization. Mechanical behavior of T-joints was performed using the T-joint pull-off test and compared to traditional tooling methods. Components made with the cellular core tooling method showed an improved strength at the joints. It is expected that this knowledge will help optimize the processing of complex, integrated structures and benefit applications in aerospace where lighter, structurally efficient components would be advantageous.

  1. [The temporomandibular joint in juvenile idiopathic arthritis: what radiologists need to look for on magnetic resonance imaging].

    PubMed

    De La Hoz Polo, M; Navallas, M

    2014-01-01

    The term "juvenile idiopathic arthritis" (JIA) encompasses a group of arthritis of unknown cause with onset before the age of 16 years that last for at least 6 weeks. The prevalence of temporomandibular joint involvement in published series ranges from 17% to 87%. Temporomandibular joint involvement is difficult to detect clinically, so imaging plays a key role in diagnosis and monitoring treatment. MRI is the technique of choice for the study of arthritis of the temporomandibular joint because it is the most sensitive technique for detecting acute synovitis and bone edema. Power Doppler ultrasonography can also detect active synovitis by showing the hypervascularization of the inflamed synovial membrane, but it cannot identify bone edema. This article describes the MRI technique for evaluating the temporomandibular joint in patients with juvenile idiopathic arthritis, defines the parameters to look for, and illustrates the main findings. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.

  2. A New Sacroiliac Joint Injection Technique and Its Short-Term Effect on Chronic Sacroiliac Region Pain.

    PubMed

    Do, Kyung Hee; Ahn, Sang Ho; Jones, Rodney; Jang, Sung Ho; Son, Su Min; Lee, Dong Gyu; Cho, Hee Kyung; Choi, Gyu Sik; Cho, Yun-Woo

    2016-10-01

    Sacroiliac joint (SIJ) injections have been used to provide short-term relief of SIJ pain. In this study, the authors investigated a new technique using a superior approach. Twenty four patients with chronic SI joint paint were recruited. Each patient was treated with a single SIJ intra-articular injection plus a periarticular injection of local anesthetic and corticosteroid in one procedure. Technical accuracy of the intra-articular procedure was determined by having 2 independent observers review and rate the quality of arthrograms obtained. Treatment effects were evaluated using a numerical rating scale, the Oswestry disability index (ODI) and global perceived effect (GPE). Both independent observers agreed that satisfactory arthrograms were obtained in all patients. Pain scores and disability were significantly reduced at 2 weeks and 4 weeks after treatment. Nineteen patients (79%) reported satisfaction with treatment. No serious adverse effects were encountered. The superior approach consistently achieves good access to the SI joint, and achieves outcomes that are compatible with those of other techniques. The superior approach constitutes an alternative to other techniques for injections into the SI joint. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. [An attempt to use ultrasonic technique for confirming the diagnosis, planning and observation of long-term treatment results of painful temporo-mandibular joint dysfunction].

    PubMed

    Ey-Chmielewska, H

    1998-01-01

    The author presents an attempt of using ultrasonographic technique in diagnosis, planning and observation of treatment results of temporo-mandibular joint pain dysfunctions. Temporo-mandibular joint pain dysfunctions are interchangeably also called temporo-mandibular joint functional disorders. The assessment of pain symptoms in temporo-mandibular joint dysfunctions pain symptoms is principally based on a subjective estimation by the examining practitioner. There is no univocal definition of the disease or a simple index evidencing important symptoms in decision making. Additionally X-ray technique examinations, being hitherto used, in early stages of the disorder do not allow to diagnose it, and are also burdensome to a patient. The aim of this study was to confirm visibility of anatomical elements of the temporo-mandibular joint in an ultrasound examination, assess the mobility of the articular disc before, during and after prosthetic treatment with and without the use of ultrasound technique, and to determine the period of time necessary to obtain a therapeutic effect. The study material consisted of 180 patients, 128 women and 52 men, aged 20 to 60 years, treated by applying prostheses because of temporo-mandibular joint pain dysfunction, in the Department of Prosthetic Dentistry of the Pomeranian Medical Academy. The patients were divided into 2 groups, control and study group. The control group consisted of 90 patients, 63 women and 27 men. In this group prosthetic treatment planning and observation of results was based on a subjective estimation of the practitioner. The study group here comprised 90 patients, 65 women and 25 men, aged 26 to 60 years. In this group prosthetic treatment planning and observation of treatment results were carried on with the use of ultrasound technique. Data from both groups concerning history, results of examinations carried out by ultrasound technique, and the assessment of ultrasound examination were noted on standard examination records used in the Department of Prosthetic Dentistry. For the need of this study an own ultrasound technique was elaborated which allowed for analyzing the ultrasound image in a static situation and during functioning. The ultrasound examination was accomplished with the use of Acuson 128 XP apparatus, linear probe 7.5 MHz. In both groups prosthetic treatment was carried out using different prosthetic methods such as: splints, occlusal adjustment on fixed prosthetic restorations in therapeutical occulus et height in abnormal occlusion. In the study group the therapeutical occulus height was determined under the control of ultrasound technique. Statistical analysis of the obtained results was performed with the use of chi-square test and chi-square test with Yates correction. On the basis of the accomplished study it has been determined that the ultrasound technique makes it possible to visualize morphological elements and facilitates functional observation of the temporo-mandibular joint, articular disc, mandibular condyle and lateral pterygoid muscle in a degree which allows for planning the treatment and the observation of results (Tab. 1-6). The use of ultrasound technique in determining spatial position of the mandible in temporo-mandibular joint permitted to objectively estimate examination results in the study group. A small number of publications on the use of ultrasound technique in functional examination of the temporo-mandibular joint accessible in foreign literature and general reference on the subject in Polish literature do not allow for an objective comparison of obtained study results.

  4. Estimating crustal thickness and Vp/Vs ratio with joint constraints of receiver function and gravity data

    NASA Astrophysics Data System (ADS)

    Shi, Lei; Guo, Lianghui; Ma, Yawei; Li, Yonghua; Wang, Weilai

    2018-05-01

    The technique of teleseismic receiver function H-κ stacking is popular for estimating the crustal thickness and Vp/Vs ratio. However, it has large uncertainty or ambiguity when the Moho multiples in receiver function are not easy to be identified. We present an improved technique to estimate the crustal thickness and Vp/Vs ratio by joint constraints of receiver function and gravity data. The complete Bouguer gravity anomalies, composed of the anomalies due to the relief of the Moho interface and the heterogeneous density distribution within the crust, are associated with the crustal thickness, density and Vp/Vs ratio. According to their relationship formulae presented by Lowry and Pérez-Gussinyé, we invert the complete Bouguer gravity anomalies by using a common algorithm of likelihood estimation to obtain the crustal thickness and Vp/Vs ratio, and then utilize them to constrain the receiver function H-κ stacking result. We verified the improved technique on three synthetic crustal models and evaluated the influence of selected parameters, the results of which demonstrated that the novel technique could reduce the ambiguity and enhance the accuracy of estimation. Real data test at two given stations in the NE margin of Tibetan Plateau illustrated that the improved technique provided reliable estimations of crustal thickness and Vp/Vs ratio.

  5. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders.

    PubMed

    Borotikar, Bhushan; Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.

  6. Self-healing bolted joint employing a shape memory actuator

    NASA Astrophysics Data System (ADS)

    Muntges, Daniel E.; Park, Gyuhae; Inman, Daniel J.

    2001-08-01

    This paper is a report of an initial investigation into the active control of preload in the joint using a shape memory actuator around the axis of the bolt shaft. Specifically, the actuator is a cylindrical Nitinol washer that expands axially when heated, according to the shape memory effect. The washer is actuated in response to an artificial decrease in torque. Upon actuation, the stress generated by its axial strain compresses the bolted members and creates a frictional force that has the effect of generating a preload and restoring lost torque. In addition to torque wrenches, the system in question was monitored in all stages of testing using piezoelectric impedance analysis. Impedance analysis drew upon research techniques developed at Center for Intelligent Material Systems and Structures, in which phase changes in the impedance of a self-sensing piezoceramic actuator correspond to changes in joint stiffness. Through experimentation, we have documented a successful actuation of the shape memory element. Due to complexity of constitutive modeling, qualitative analysis by the impedance method is used to illustrate the success. Additional considerations encountered in this initial investigation are made to guide further thorough research required for the successful commercial application of this promising technique.

  7. Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review

    PubMed Central

    Toh, Wei Quan; Liu, Erjia; Tor, Shu Beng

    2017-01-01

    Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human body has brought about the revival of metal-on-metal (MOM) hip joints in recent years. This has also led to a relatively new research area that links tribology and corrosion together. This article aims at reviewing the commonly used tribochemical methods adopted in the analysis of tribocorrosion and putting forward some of the models and environmental factors affecting the tribocorrosive behavior of CoCrMo alloys, a widely-used class of biomaterial for orthopedic implants. PMID:29278375

  8. Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review.

    PubMed

    Toh, Wei Quan; Tan, Xipeng; Bhowmik, Ayan; Liu, Erjia; Tor, Shu Beng

    2017-12-26

    Orthopedic implants first started out as an all-metal hip joint replacement. However, poor design and machinability as well as unsatisfactory surface finish subjected the all-metal joint replacement to being superseded by a polyethylene bearing. Continued improvement in manufacturing techniques together with the reality that polyethylene wear debris can cause hazardous reactions in the human body has brought about the revival of metal-on-metal (MOM) hip joints in recent years. This has also led to a relatively new research area that links tribology and corrosion together. This article aims at reviewing the commonly used tribochemical methods adopted in the analysis of tribocorrosion and putting forward some of the models and environmental factors affecting the tribocorrosive behavior of CoCrMo alloys, a widely-used class of biomaterial for orthopedic implants.

  9. Joint inversion of fundamental and higher mode Rayleigh waves

    USGS Publications Warehouse

    Luo, Y.-H.; Xia, J.-H.; Liu, J.-P.; Liu, Q.-S.

    2008-01-01

    In this paper, we analyze the characteristics of the phase velocity of fundamental and higher mode Rayleigh waves in a six-layer earth model. The results show that fundamental mode is more sensitive to the shear velocities of shallow layers (< 7 m) and concentrated in a very narrow band (around 18 Hz) while higher modes are more sensitive to the parameters of relatively deeper layers and distributed over a wider frequency band. These properties provide a foundation of using a multi-mode joint inversion to define S-wave velocity. Inversion results of both synthetic data and a real-world example demonstrate that joint inversion with the damped least squares method and the SVD (Singular Value Decomposition) technique to invert Rayleigh waves of fundamental and higher modes can effectively reduce the ambiguity and improve the accuracy of inverted S-wave velocities.

  10. Double needle technique: an alternative method for performing difficult sacroiliac joint injections.

    PubMed

    Gupta, Sanjeeva

    2011-01-01

    The sacroiliac joint (SIJ) is a common source of low back pain. The most appropriate method of confirming SIJ pain is to inject local anesthesia into the joint to find out if the pain decreases. Unfortunately, although the SIJ is a large joint, it can be difficult to enter due to the complex nature of the joint and variations in anatomy. In my experience a double needle technique for sacroiliac joint injection can increase the chances of accurate injection into the SIJ in difficult cases. After obtaining appropriate fluoroscopic images, the tip of the needle is advanced into the SIJ. Once the tip of the needle is correctly placed, its position is checked under continuous fluoroscopy while moving the C-arm in the right and left oblique directions (dynamic fluoroscopy). On dynamic fluoroscopy the tip of the needle should remain within the joint line and not appear to be on the bone. If the tip of the needle appears to be on the bone a new joint line will need to be identified (the most translucent area through the joint) by dynamic fluoroscopy and another needle advanced into the newly identified joint line. Dynamic fluoroscopy is repeated again to confirm that the tip of the second needle remains within the joint line. Once both needles are in place contrast dye is injected through the needle that is most likely to be in the SIJ. If the contrast dye spread is not satisfactory then it is injected through the other needle. I have used this technique in 10 patients and found it very helpful in accurately performing SIJ injection which can at times be challenging.

  11. Upper limb joint kinetics of three sitting pivot wheelchair transfer techniques in individuals with spinal cord injury

    PubMed Central

    Kankipati, Padmaja; Boninger, Michael L.; Gagnon, Dany; Cooper, Rory A.; Koontz, Alicia M.

    2015-01-01

    Study design Repeated measures design. Objective This study compared the upper extremity (UE) joint kinetics between three transfer techniques. Setting Research laboratory. Methods Twenty individuals with spinal cord injury performed three transfer techniques from their wheelchair to a level tub bench. Two of the techniques involved a head–hips method with leading hand position close (HH-I) and far (HH-A) from the body, and the third technique with the trunk upright (TU) and hand far from body. Motion analysis equipment recorded upper body movements and force sensors recorded their hand and feet reaction forces during the transfers. Results Several significant differences were found between HH-A and HH-I and TU and HH-I transfers indicating that hand placement was a key factor influencing the UE joint kinetics. Peak resultant hand, elbow, and shoulder joint forces were significantly higher for the HH-A and TU techniques at the trailing arm (P < 0.036) and lower at the leading arm (P < 0.021), compared to the HH-I technique. Conclusion Always trailing with the same arm if using HH-A or TU could predispose that arm to overuse related pain and injuries. Technique training should focus on initial hand placement close to the body followed by the amount of trunk flexion needed to facilitate movement. PMID:25130053

  12. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions.

    PubMed

    Farina, Ana Paula; Spazzin, Aloísio Oro; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz

    2014-06-01

    Screws can loosen through mechanisms that have not been clearly established. The purpose of this study was to evaluate the influence of the tightening technique (the application of torque and retorque on the joint stability of titanium and gold prosthetic screws) in implant-supported dentures under different fit levels after 1 year of simulated masticatory function by means of mechanical cycling. Ten mandibular implant-supported dentures were fabricated, and 20 cast models were prepared by using the dentures to create 2 fit levels: passive fit and created misfit. The tightening protocol was evaluated according to 4 distinct profiles: without retorque plus titanium screws, without retorque plus gold screws, retorque plus titanium screws, and retorque plus gold screws. In the retorque application, the screws were tightened to 10 Ncm and retightened to 10 Ncm after 10 minutes. The screw joint stability after 1 year of simulated clinical function was measured with a digital torque meter. Data were analyzed statistically by 2-way ANOVA and Tukey honestly significant difference (HSD) post hoc tests (α=.05). The factors of fit level and tightening technique as well as the interaction between the factors, were statistically significant. The misfit decreases the loosening torque. The retorque application increased joint stability independent of fit level or screw material, which suggests that this procedure should be performed routinely during the tightening of these devices. All tightening techniques revealed reduced loosening torque values that were significantly lower in misfit dentures than in passive fit dentures. However, the retorque application significantly increased the loosening torque when titanium and gold screws were used. Therefore, this procedure should be performed routinely during screw tightening. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  13. Fuzzy logic based robotic controller

    NASA Technical Reports Server (NTRS)

    Attia, F.; Upadhyaya, M.

    1994-01-01

    Existing Proportional-Integral-Derivative (PID) robotic controllers rely on an inverse kinematic model to convert user-specified cartesian trajectory coordinates to joint variables. These joints experience friction, stiction, and gear backlash effects. Due to lack of proper linearization of these effects, modern control theory based on state space methods cannot provide adequate control for robotic systems. In the presence of loads, the dynamic behavior of robotic systems is complex and nonlinear, especially where mathematical modeling is evaluated for real-time operators. Fuzzy Logic Control is a fast emerging alternative to conventional control systems in situations where it may not be feasible to formulate an analytical model of the complex system. Fuzzy logic techniques track a user-defined trajectory without having the host computer to explicitly solve the nonlinear inverse kinematic equations. The goal is to provide a rule-based approach, which is closer to human reasoning. The approach used expresses end-point error, location of manipulator joints, and proximity to obstacles as fuzzy variables. The resulting decisions are based upon linguistic and non-numerical information. This paper presents a solution to the conventional robot controller which is independent of computationally intensive kinematic equations. Computer simulation results of this approach as obtained from software implementation are also discussed.

  14. Kinematic analysis of total knee prosthesis designed for Asian population.

    PubMed

    Low, F H; Khoo, L P; Chua, C K; Lo, N N

    2000-01-01

    In designing a total knee replacement (TKR) prosthesis catering for the Asian population, 62 sets of femur were harvested and analyzed. The morphometrical data obtained were found to be in good agreement with dimensions typical of the Asian knee and has reaffirmed the fact that Caucasian knees are generally larger than Asian knees. Subsequently, these data when treated using a multivariate statistical technique resulted in the establishment of major design parameters for six different sizes of femoral implants. An extra-small implant size with established dimensions and geometrical shape has surfaced from the study. The differences between the Asian knees and the Caucasian knees are discussed. Employing the established femoral dimensions and motion path of the knee joint, the articulating tibia profile was generated. All the sizes of implants were modeled using a computer-aided software package. Thereupon, these models that accurately fits the local Asian knee were transported into a dynamic and kinematic analysis software package. The tibiofemoral joint was modeled successfully as a slide curve joint to study intuitively the motion of the femur when articulating on the tibia surface. An optimal tibia profile could be synthesized to mimic the natural knee path motion. Details of the analysis are presented and discussed.

  15. The impact of high-heeled shoes on ankle complex during walking in young women-In vivo kinematic study based on 3D to 2D registration technique.

    PubMed

    Wang, Chen; Geng, Xiang; Wang, Shaobai; Ma, Xin; Wang, Xu; Huang, Jiazhang; Zhang, Chao; Chen, Li; Yang, Junsheng; Li, Jiabei; Wang, Kan

    2016-06-01

    To explore the accurate in vivo kinematic changes in the ankle complex when wearing low- and high-heel shoes (LHS and HHS, respectively). Twelve young women were tested unilaterally. Three-dimensional models of the tibia, talus, and calcaneus were first created based on CT scan results. The subjects walked at a self-controlled speed in barefoot, LHS (4cm), and HHS (10cm) conditions. A fluoroscopy system captured the lateral fluoroscopic images of the ankle complex. The images of seven key positions in the stance phase were selected, and 3D to 2D bone model registrations were performed to determine the joint positions. The mean of 6 degree of freedom (DOF) range of motions (ROM), joint positions, and angular displacements of the ankle complex during the gait were then obtained. For the talocrural joint, the rotational ROMs of the subjects either in LHS or HHS condition displayed no significant difference from those in barefoot condition. For the subtalar joint, all the rotational ROMs in the HHS condition and the internal/external rotations in the LHS condition significantly decreased compared with those in the barefoot condition. The talocrural joint was positioned significantly more plantarflexed, inverted, internally rotated, and posteriorly seated in all seven poses in HHS condition, compared with those in barefoot condition. HHS mainly affected the rotational motion of the ankle complex during walking. The talocrural joint position was abnormal, and the subtalar joint ROM decreased during the gait in HHS condition. Only a few kinematic changes occurred in LHS condition relative to the barefoot condition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Sacroiliac Joint Interventions.

    PubMed

    Soto Quijano, David A; Otero Loperena, Eduardo

    2018-02-01

    Sacroiliac joint (SIJ) pain is an important cause of lower back problems. Multiple SIJ injection techniques have been proposed over the years to help in the diagnosis and treatment of this condition. However, the SIJ innervation is complex and variable, and truly intra-articular injections are sometimes difficult to obtain. Different sacroiliac joint injections have shown to provide pain relief in patients suffering this ailment. Various techniques for intraarticular injections, sacral branch blocks and radiofrequency ablation, both fluoroscopy guided and ultrasound guided are discussed in this paper. Less common techniques like prolotherapy, platelet rich plasma injections and botulism toxin injections are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Testing of printed circuit board solder joints by optical correlation

    NASA Technical Reports Server (NTRS)

    Espy, P. N.

    1975-01-01

    An optical correlation technique for the nondestructive evaluation of printed circuit board solder joints was evaluated. Reliable indications of induced stress levels in solder joint lead wires are achievable. Definite relations between the inherent strength of a solder joint, with its associated ability to survive stress, are demonstrable.

  18. Investigation of the feasibility of an analytical method of accounting for the effects of atmospheric drag on satellite motion

    NASA Technical Reports Server (NTRS)

    Bozeman, Robert E.

    1987-01-01

    An analytic technique for accounting for the joint effects of Earth oblateness and atmospheric drag on close-Earth satellites is investigated. The technique is analytic in the sense that explicit solutions to the Lagrange planetary equations are given; consequently, no numerical integrations are required in the solution process. The atmospheric density in the technique described is represented by a rotating spherical exponential model with superposed effects of the oblate atmosphere and the diurnal variations. A computer program implementing the process is discussed and sample output is compared with output from program NSEP (Numerical Satellite Ephemeris Program). NSEP uses a numerical integration technique to account for atmospheric drag effects.

  19. JANNAF 36th Combustion Subcommittee Meeting. Volume 1

    NASA Technical Reports Server (NTRS)

    Fry, Ronald S. (Editor); Gannaway, Mary T. (Editor)

    1999-01-01

    Volume 1, the first of three volumes is a compilation of 47 unclassified/unlimited-distribution technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 36th Combustion Subcommittee held jointly with the 24th Airbreathing Propulsion Subcommittee and 18th Propulsion Systems Hazards Subcommittee. The meeting was held on 18-21 October 1999 at NASA Kennedy Space Center and The DoubleTree Oceanfront Hotel, Cocoa Beach, Florida. Solid phase propellant combustion topics covered in this volume include cookoff phenomena in the pre- and post-ignition phases, solid rocket motor and gun propellant combustion, aluminized composite propellant combustion, combustion modeling and combustion instability and instability measurement techniques.

  20. In-situ sensory technique for in-service quality monitoring: measurement of the complex Young's modulus of polymers

    NASA Astrophysics Data System (ADS)

    Zhou, Shunhua; Liang, Chen; Rogers, Craig A.; Sun, Fanping P.; Vick, L.

    1993-07-01

    Applications of polymeric adhesives in joining different materials have necessitated quantitative health inspection of adhesive joints (coverage, state of cure, adhesive strength, location of voids, etc.). A new in-situ sensory method has been proposed in this paper to inspect the amount and distribution of the critical constituents of polymers and to measure the characteristic parameters (complex Young's modulus and damping). In this technique, ferromagnetic particles have been embedded in a polymeric matrix, similar to a particle- reinforced composite. The dynamic signatures extracted from the tests as a result of magnetic excitation of the embedded ferromagnetic particles are used to evaluate the complex Young's modulus of the host polymers. Moreover, the amplitude of the frequency response is utilized to identify the amount and distribution of embedded particles in polymeric materials or adhesive joints. The results predicted from the theoretical model agree well with the experimental results. The theoretical analyses and the experimental work conducted have demonstrated the utility of the sensory technique presented for in-service health interrogation.

  1. Bioleach: a mathematical model for the joint evaluation of leachate and biogas production in urban solid waste landfills

    NASA Astrophysics Data System (ADS)

    Rodrigo-Clavero, Maria-Elena; Rodrigo-Ilarri, Javier

    2017-04-01

    One of the most serious environmental problems in modern societies is the management and disposal of urban solid waste (MSW). Despite the efforts of the administration to promote recycling and reuse policies and energy recovery technologies, nowadays the majority of MSW still is disposed in sanitary landfills. During the phases of operation and post-closure maintenance of any solid waste disposal site, two of the most relevant problems are the production of leachate and the generation of biogas. The leachate and biogas production formation processes occur simultaneously over time and are coupled together through the consumption and/or production of water. However, no mathematical models have been easily identified that allow to the evaluation of the joint production of leachate and biogas, during the operational and the post-closure phase of an urban waste landfill. This paper introduces BIOLEACH, a new mathematical model programmed on a monthly scale, that evaluates the joint production of leachate and biogas applying water balance techniques and considers the management of the landfill as a bioreactor. The application of such a model on real landfills allows to perform an environmentally sustainable management that minimizes the environmental impacts produced being also economically more profitable.

  2. A Computational Model of Torque Generation: Neural, Contractile, Metabolic and Musculoskeletal Components

    PubMed Central

    Callahan, Damien M.; Umberger, Brian R.; Kent-Braun, Jane A.

    2013-01-01

    The pathway of voluntary joint torque production includes motor neuron recruitment and rate-coding, sarcolemmal depolarization and calcium release by the sarcoplasmic reticulum, force generation by motor proteins within skeletal muscle, and force transmission by tendon across the joint. The direct source of energetic support for this process is ATP hydrolysis. It is possible to examine portions of this physiologic pathway using various in vivo and in vitro techniques, but an integrated view of the multiple processes that ultimately impact joint torque remains elusive. To address this gap, we present a comprehensive computational model of the combined neuromuscular and musculoskeletal systems that includes novel components related to intracellular bioenergetics function. Components representing excitatory drive, muscle activation, force generation, metabolic perturbations, and torque production during voluntary human ankle dorsiflexion were constructed, using a combination of experimentally-derived data and literature values. Simulation results were validated by comparison with torque and metabolic data obtained in vivo. The model successfully predicted peak and submaximal voluntary and electrically-elicited torque output, and accurately simulated the metabolic perturbations associated with voluntary contractions. This novel, comprehensive model could be used to better understand impact of global effectors such as age and disease on various components of the neuromuscular system, and ultimately, voluntary torque output. PMID:23405245

  3. A mixed-penalty biphasic finite element formulation incorporating viscous fluids and material interfaces.

    PubMed

    Chan, B; Donzelli, P S; Spilker, R L

    2000-06-01

    The fluid viscosity term of the fluid phase constitutive equation and the interface boundary conditions between biphasic, solid and fluid domains have been incorporated into a mixed-penalty finite element formulation of the linear biphasic theory for hydrated soft tissue. The finite element code can now model a single-phase viscous incompressible fluid, or a single-phase elastic solid, as limiting cases of a biphasic material. Interface boundary conditions allow the solution of problems involving combinations of biphasic, fluid and solid regions. To incorporate these conditions, the volume-weighted mixture velocity is introduced as a degree of freedom at interface nodes so that the kinematic continuity conditions are satisfied by conventional finite element assembly techniques. Results comparing our numerical method with an independent, analytic solution for the problem of Couette flow over rigid and deformable porous biphasic layers show that the finite element code accurately predicts the viscous fluid flows and deformation in the porous biphasic region. Thus, the analysis can be used to model the interface between synovial fluid and articular cartilage in diarthrodial joints. This is an important step toward modeling and understanding the mechanisms of joint lubrication and another step toward fully modeling the in vivo behavior of a diarthrodial joint.

  4. Optimizing pulsed Nd:YAG laser beam welding process parameters to attain maximum ultimate tensile strength for thin AISI316L sheet using response surface methodology and simulated annealing algorithm

    NASA Astrophysics Data System (ADS)

    Torabi, Amir; Kolahan, Farhad

    2018-07-01

    Pulsed laser welding is a powerful technique especially suitable for joining thin sheet metals. In this study, based on experimental data, pulsed laser welding of thin AISI316L austenitic stainless steel sheet has been modeled and optimized. The experimental data required for modeling are gathered as per Central Composite Design matrix in Response Surface Methodology (RSM) with full replication of 31 runs. Ultimate Tensile Strength (UTS) is considered as the main quality measure in laser welding. Furthermore, the important process parameters including peak power, pulse duration, pulse frequency and welding speed are selected as input process parameters. The relation between input parameters and the output response is established via full quadratic response surface regression with confidence level of 95%. The adequacy of the regression model was verified using Analysis of Variance technique results. The main effects of each factor and the interactions effects with other factors were analyzed graphically in contour and surface plot. Next, to maximum joint UTS, the best combinations of parameters levels were specified using RSM. Moreover, the mathematical model is implanted into a Simulated Annealing (SA) optimization algorithm to determine the optimal values of process parameters. The results obtained by both SA and RSM optimization techniques are in good agreement. The optimal parameters settings for peak power of 1800 W, pulse duration of 4.5 ms, frequency of 4.2 Hz and welding speed of 0.5 mm/s would result in a welded joint with 96% of the base metal UTS. Computational results clearly demonstrate that the proposed modeling and optimization procedures perform quite well for pulsed laser welding process.

  5. Fatigue limits of titanium-bar joints made with the laser and the electric resistance welding techniques: microstructural characterization and hardness properties.

    PubMed

    Degidi, Marco; Nardi, Diego; Morri, Alessandro; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio

    2017-09-01

    Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).

  6. A harmonic analysis approach to joint inversion of P-receiver functions and wave dispersion data in high dense seismic profiles

    NASA Astrophysics Data System (ADS)

    Molina-Aguilera, A.; Mancilla, F. D. L.; Julià, J.; Morales, J.

    2017-12-01

    Joint inversion techniques of P-receiver functions and wave dispersion data implicitly assume an isotropic radial stratified earth. The conventional approach invert stacked radial component receiver functions from different back-azimuths to obtain a laterally homogeneous single-velocity model. However, in the presence of strong lateral heterogeneities as anisotropic layers and/or dipping interfaces, receiver functions are considerably perturbed and both the radial and transverse components exhibit back azimuthal dependences. Harmonic analysis methods exploit these azimuthal periodicities to separate the effects due to the isotropic flat-layered structure from those effects caused by lateral heterogeneities. We implement a harmonic analysis method based on radial and transverse receiver functions components and carry out a synthetic study to illuminate the capabilities of the method in isolating the isotropic flat-layered part of receiver functions and constrain the geometry and strength of lateral heterogeneities. The independent of the baz P receiver function are jointly inverted with phase and group dispersion curves using a linearized inversion procedure. We apply this approach to high dense seismic profiles ( 2 km inter-station distance, see figure) located in the central Betics (western Mediterranean region), a region which has experienced complex geodynamic processes and exhibit strong variations in Moho topography. The technique presented here is robust and can be applied systematically to construct a 3-D model of the crust and uppermost mantle across large networks.

  7. Demonstration of movement in the sacroiliac joint using ultrasound

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Brooks, William J.; Lund, Pamela J.

    1995-05-01

    The goal of this study was to demonstrate quantitatively, using ultrasound (US) recording techniques, the extent of motion of the sacroiliac joint achieved using manual medicine techniques. Initial judgements of perceived (i.e., felt) SI mobility during manual examination were made on 22 subjects. Baseline no movement ultrasound images (static) were obtained of the left and right SI joints at two levels-- posterior-superior-iliac-spine and inferior (PSIS, INF)--and two projections (AP and LAT). Manual medicine spring testing of the SI joint was then performed while ultrasound recordings (on video) were made. The differences between baseline separation of the SI joint and displacement distance during spring testing were measured by six radiologists who typically read US images. Significant movement of at least one SI joint was demonstrated in 91% of the subjects using ultrasound recordings. The extent of movement appeared to corroborate the experience of manual medicine practitioners.

  8. Vascularised knee joint transplantation in man: the first two years experience.

    PubMed

    Kirschner, M H; Brauns, L; Gonschorek, O; Bühren, V; Hofmann, G O

    2000-04-01

    To describe our early experience with a new technique for restoring destroyed knee joints to give reasonable functional results. Observational clinical trial. Level-1-Trauma centre, Germany. 5 patients with large bone defects of the knee and loss of the extensor apparatus caused either by serious injury alone, or infection after serious injury. Transplantation of fresh and perfused knee joints with a vascular pedicle from multiorgan donors under immunosuppression. Ability to walk, need to remove one transplanted joint. Four patients are able to walk, the range of movement being from 50 degrees-120 degrees. The first patient additionally had to be provided with a total knee joint arthroplasty. In the third patient the graft became infected and had to be removed. She finally had an arthrodesis and bone lengthening by the Ilizarov technique. Transplantation of the knee joint may be an alternative to bone lengthening or amputation for patients with total loss of the extensor apparatus.

  9. Wavelet filtered shifted phase-encoded joint transform correlation for face recognition

    NASA Astrophysics Data System (ADS)

    Moniruzzaman, Md.; Alam, Mohammad S.

    2017-05-01

    A new wavelet-filtered-based Shifted- phase-encoded Joint Transform Correlation (WPJTC) technique has been proposed for efficient face recognition. The proposed technique uses discrete wavelet decomposition for preprocessing and can effectively accommodate various 3D facial distortions, effects of noise, and illumination variations. After analyzing different forms of wavelet basis functions, an optimal method has been proposed by considering the discrimination capability and processing speed as performance trade-offs. The proposed technique yields better correlation discrimination compared to alternate pattern recognition techniques such as phase-shifted phase-encoded fringe-adjusted joint transform correlator. The performance of the proposed WPJTC has been tested using the Yale facial database and extended Yale facial database under different environments such as illumination variation, noise, and 3D changes in facial expressions. Test results show that the proposed WPJTC yields better performance compared to alternate JTC based face recognition techniques.

  10. Experimental Investigation of Solder Joint Defect Formation and Mitigation in Reduced-Gravity Environments

    NASA Technical Reports Server (NTRS)

    Watson, J. Kevin; Struk, Peter M.; Pettegrew, RIchard D.; Downs, Robert S.

    2006-01-01

    This paper documents a research effort on reduced gravity soldering of plated through hole joints which was conducted jointly by the National Center for Space Exploration Research, NASA Glenn Research Center, and NASA Johnson Space Center. Significant increases in joint porosity and changes in external geometry were observed in joints produced in reduced gravity as compared to normal gravity. Multiple techniques for mitigating the observed increase in porosity were tried, including several combinations of flux and solder application techniques, and demoisturizing the circuit board prior to soldering. Results were consistent with the hypothesis that the source of the porosity is a combination of both trapped moisture in the circuit board itself, as well as vaporized flux that is trapped in the molten solder. Other topics investigated include correlation of visual inspection results with joint porosity, pore size measurements, limited pressure effects (0.08 MPa - 0.1 MPa) on the size and number of pores, and joint cooling rate.

  11. Nikolaus Rüdinger (1832-1896), His Description of Joint Innervation in 1857, and the History of Surgical Joint Denervation.

    PubMed

    Gohritz, Andreas; Kaiser, Erich; Guggenheim, Merlin; Dellon, Arnold Lee

    2018-01-01

     Selective joint denervation has become a reliable palliative treatment, especially for painful joints in the upper and lower extremity.  This article highlights the life and work of Nikolaus Rüdinger (1832-1896) who first described joint innervation which became the basis of later techniques of surgical joint denervation. The historical evolution of this method is outlined.  Rüdinger made a unique career from apprentice barber to military surgeon and anatomy professor in Munich, Germany. His first description of articular innervation of temporomandibular, shoulder, elbow, wrist, finger, sacroiliac, hip, knee, ankle, foot, and toe joints in 1857 stimulated the subsequent history of surgical joint denervation. Comparing his investigations with modern joint denervation methods, developed by pioneers like Albrecht Wilhelm or A. Lee Dellon, shows his great exactitude and anatomical correspondence despite different current terminology. Clinical series of modern surgical joint denervations reveal success rates of up to 80% with reliable long-term results.  The history of joint denervation with Rüdinger as its important protagonist offers inspiring insights into the evolution of surgical techniques and exemplifies the value of descriptive functional anatomy, even if surgical application may not have been realized until a century later. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Efficient Ensemble State-Parameters Estimation Techniques in Ocean Ecosystem Models: Application to the North Atlantic

    NASA Astrophysics Data System (ADS)

    El Gharamti, M.; Bethke, I.; Tjiputra, J.; Bertino, L.

    2016-02-01

    Given the recent strong international focus on developing new data assimilation systems for biological models, we present in this comparative study the application of newly developed state-parameters estimation tools to an ocean ecosystem model. It is quite known that the available physical models are still too simple compared to the complexity of the ocean biology. Furthermore, various biological parameters remain poorly unknown and hence wrong specifications of such parameters can lead to large model errors. Standard joint state-parameters augmentation technique using the ensemble Kalman filter (Stochastic EnKF) has been extensively tested in many geophysical applications. Some of these assimilation studies reported that jointly updating the state and the parameters might introduce significant inconsistency especially for strongly nonlinear models. This is usually the case for ecosystem models particularly during the period of the spring bloom. A better handling of the estimation problem is often carried out by separating the update of the state and the parameters using the so-called Dual EnKF. The dual filter is computationally more expensive than the Joint EnKF but is expected to perform more accurately. Using a similar separation strategy, we propose a new EnKF estimation algorithm in which we apply a one-step-ahead smoothing to the state. The new state-parameters estimation scheme is derived in a consistent Bayesian filtering framework and results in separate update steps for the state and the parameters. Unlike the classical filtering path, the new scheme starts with an update step and later a model propagation step is performed. We test the performance of the new smoothing-based schemes against the standard EnKF in a one-dimensional configuration of the Norwegian Earth System Model (NorESM) in the North Atlantic. We use nutrients profile (up to 2000 m deep) data and surface partial CO2 measurements from Mike weather station (66o N, 2o E) to estimate different biological parameters of phytoplanktons and zooplanktons. We analyze the performance of the filters in terms of complexity and accuracy of the state and parameters estimates.

  13. Fully probabilistic control for stochastic nonlinear control systems with input dependent noise.

    PubMed

    Herzallah, Randa

    2015-03-01

    Robust controllers for nonlinear stochastic systems with functional uncertainties can be consistently designed using probabilistic control methods. In this paper a generalised probabilistic controller design for the minimisation of the Kullback-Leibler divergence between the actual joint probability density function (pdf) of the closed loop control system, and an ideal joint pdf is presented emphasising how the uncertainty can be systematically incorporated in the absence of reliable systems models. To achieve this objective all probabilistic models of the system are estimated from process data using mixture density networks (MDNs) where all the parameters of the estimated pdfs are taken to be state and control input dependent. Based on this dependency of the density parameters on the input values, explicit formulations to the construction of optimal generalised probabilistic controllers are obtained through the techniques of dynamic programming and adaptive critic methods. Using the proposed generalised probabilistic controller, the conditional joint pdfs can be made to follow the ideal ones. A simulation example is used to demonstrate the implementation of the algorithm and encouraging results are obtained. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. The Effects of Manual Therapy Using Joint Mobilization and Flexion-distraction Techniques on Chronic Low Back Pain and Disc Heights

    PubMed Central

    Choi, Jioun; Hwangbo, Gak; Park, Jungseo; Lee, Sangyong

    2014-01-01

    [Purpose] The purpose of this study was to examine the effects of manual therapy using joint mobilization and flexion-distraction techniques on chronic low back pain and disc heights. [Subjects] This study was conducted with 31 chronic low back pain patients who were divided into a manual therapy group (MTG; n=16) and a spinal decompression therapy group (SDTG; n=15). [Methods] The MTG was treated using joint mobilization techniques and flexion-distraction techniques, and the SDTG was treated using spinal decompression therapeutic apparatuses. Conservative physical therapy was used in both groups, and the therapy was implemented three times per week for 6 weeks. The visual analog scale (VAS) was used to measure patient’s low back pain scores, and a picture archiving and communication system was used to measure disc height by comparing and analyzing the images. [Results] In comparisons of the VAS within each of the two groups, both the MTG and the SDTG showed significant decreases. In comparisons of disc height within each of the two groups, the MTG showed statistically significant increases. [Conclusion] Manual therapy using joint mobilization techniques and flexion-distraction techniques is considered an effective intervention for addressing low back pain and disc heights in patients with chronic low back pain. PMID:25202191

  15. Modified Labial Button Technique for Maintaining Occlusion After Caudal Mandibular Fracture/Temporomandibular Joint Luxation in the Cat.

    PubMed

    Goodman, Alice E; Carmichael, Daniel T

    2016-03-01

    Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.

  16. Establishment of temporomandibular joint puncture technique in rats using in vivo micro-computed tomography (R_mCT®)

    PubMed Central

    Kameoka, S; Matsumoto, K; Kai, Y; Yonehara, Y; Arai, Y; Honda, K

    2010-01-01

    The aim of the report was to establish puncture techniques for the temporomandibular joint (TMJ) cavity in rats. The experimental sample comprised 30 male Sprague–Dawley rats. Under general anaesthesia the superior joint cavity of the rat was punctured either laterally (lateral puncture technique (LPT), n = 11), anteriorly (anterosuperior puncture technique (ASPT), n = 13) or anteroinferior puncture technique (AIPT), n = 6) using a 27-gauge needle. After the tip of the needle was confirmed by micro-CT (R-mCT®, Rigaku, Tokyo, Japan) located on the mandibular fossa, 0.05 ml of contrast media was injected under micro-CT fluoroscopic guidance. After confirmation that the joint cavity was filled with contrast media, micro-CT imaging was carried out. The puncture for LPT was accurate in 5 of the 11 animals. The ASPT was accurate in all 13 animals. The AIPT punctured 3 of the 6 animals. Furthermore, the ASPT and AIPT demonstrated improved preservation of the needle; it was harder to detach the needle, which led to greater stability. These results suggest that ASPT assisted by R-mCT® is useful for basic research, including drug discovery and pathogenesis of TMJ diseases. PMID:20841463

  17. Advanced Multivariate Inversion Techniques for High Resolution 3D Geophysical Modeling

    DTIC Science & Technology

    2011-09-01

    of seismic ambient noise – has been used to image crustal Vs variation with a lateral resolution upward of 100 km either on regional or on sub...to East Africa, we solve for velocity structure in an area with less lateral heterogeneity but great tectonic complexity. To increase the...demonstrate correlation with crustal geology. Figure 1 shows the 3D S-wave velocity model obtained from the joint inversion. The low-velocity anomaly

  18. Parametric representation of weld fillets using shell finite elements—a proposal based on minimum stiffness and inertia errors

    NASA Astrophysics Data System (ADS)

    Echer, L.; Marczak, R. J.

    2018-02-01

    The objective of the present work is to introduce a methodology capable of modelling welded components for structural stress analysis. The modelling technique was based on the recommendations of the International Institute of Welding; however, some geometrical features of the weld fillet were used as design parameters in an optimization problem. Namely, the weld leg length and thickness of the shell elements representing the weld fillet were optimized in such a way that the first natural frequencies were not changed significantly when compared to a reference result. Sequential linear programming was performed for T-joint structures corresponding to two different structural details: with and without full penetration weld fillets. Both structural details were tested in scenarios of various plate thicknesses and depths. Once the optimal parameters were found, a modelling procedure was proposed for T-shaped components. Furthermore, the proposed modelling technique was extended for overlapped welded joints. The results obtained were compared to well-established methodologies presented in standards and in the literature. The comparisons included results for natural frequencies, total mass and structural stress. By these comparisons, it was observed that some established practices produce significant errors in the overall stiffness and inertia. The methodology proposed herein does not share this issue and can be easily extended to other types of structure.

  19. SRB Environment Evaluation and Analysis. Volume 2: RSRB Joint Filling Test/Analysis Improvements

    NASA Technical Reports Server (NTRS)

    Knox, E. C.; Woods, G. Hamilton

    1991-01-01

    Following the Challenger accident a very comprehensive solid rocket booster (SRB) redesign program was initiated. One objective of the program was to develop expertise at NASA/MSFC in the techniques for analyzing the flow of hot gases in the SRB joints. Several test programs were undertaken to provide a data base of joint performance with manufactured defects in the joints to allow hot gases to fill the joints. This data base was used also to develop the analytical techniques. Some of the test programs were Joint Environment Simulator (JES), Nozzle Joint Environment Simulator (NJES), Transient Pressure Test Article (TPTA), and Seventy-Pound Charge (SPC). In 1988 the TPTA test hardware was moved from the Utah site to MSFC and several RSRM tests were scheduled, to be followed by tests for the ASRM program. REMTECH Inc. supported these activities with pretest estimates of the flow conditions in the test joints, and post-test analysis and evaluation of the measurements. During this support REMTECH identified deficiencies in the gas-measurement instrumentation that existed in the TPTA hardware, made recommendations for its replacement, and identified improvements to the analytical tools used in the test support. Only one test was completed under the TPTA RSRM test program, and those scheduled for the ASRM were rescheduled to a time after the expiration of this contract. The attention of this effort was directed toward improvements in the analytical techniques in preparation for when the ASRM program begins.

  20. Preliminary results on the development of vacuum brazed joints for cryogenic wind tunnel aerofoil models

    NASA Technical Reports Server (NTRS)

    Wigley, D. A.; Sandefur, P. G., Jr.; Lawing, P. L.

    1981-01-01

    The results of initial experiments show that high-strength void-free bonds can be formed by vacuum brazing of stainless steels using copper and nickel-based filler metals. In Nitronic 40, brazed joints have been formed with strengths in excess of the yield strength of the parent metal, and even at liquid nitrogen temperatures the excellent mechanical properties of the parent metal are only slightly degraded. The poor toughness of 15-5 P.H. stainless steel at cryogenic temperatures is lowered even further by the presence of the brazed bonds investigated. It is highly unlikely that the technique would be used for any critical areas of aerofoil models intended for low-temperature service. Nevertheless, the potential advantages of this simplified method of construction still have attractions for use at ambient temperatures.

  1. Chains are more flexible under tension

    PubMed Central

    Carrillo, Jan-Michael Y.; Rubinstein, Michael

    2010-01-01

    The mechanical response of networks, gels, and brush layers is a manifestation of the elastic properties of the individual macromolecules. Furthermore, the elastic response of macromolecules to an applied force is the foundation of the single-molecule force spectroscopy techniques. The two main classes of models describing chain elasticity include the worm-like and freely-jointed chain models. The selection between these two classes of models is based on the assumptions about chain flexibility. In many experimental situations the choice is not clear and a model describing the crossover between these two limiting classes is therefore in high demand. We are proposing a unified chain deformation model which describes the force-deformation curve in terms of the chain bending constant K and bond length b. This model demonstrates that the worm-like and freely-jointed chain models correspond to two different regimes of polymer deformation and the crossover between these two regimes depends on the chain bending rigidity and the magnitude of the applied force. Polymer chains with bending constant K>1 behave as a worm-like chain under tension in the interval of the applied forces f ≤ KkBT/b and as a freely-jointed chain for f ≥ KkBT/b (kB is the Boltzmann constant and T is the absolute temperature). The proposed crossover expression for chain deformation is in excellent agreement with the results of the molecular dynamics simulations of chain deformation and single-molecule deformation experiments of biological and synthetic macromolecules. PMID:21415940

  2. Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders

    PubMed Central

    Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain

    2017-01-01

    Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions. PMID:29232401

  3. Closed reduction of a rare type III dislocation of the first metatarsophalangeal joint.

    PubMed

    Tondera, E K; Baker, C C

    1996-09-01

    To discuss a rare Type III dislocation of the first metatarsophalangeal (MP) joint, without fracture, that used a closed reduction technique for correction. A 43-yr-old man suffered from an acute severe dislocation of his great toe as the result of acute forceful motion applied to the toe as his foot was depressed onto a brake pedal to avoid a motor vehicle accident. Physical examination and X-rays revealed the dislocation, muscle spasm, edema and severely restricted range of motion. The dislocation was corrected using a closed reduction technique, in this case a chiropractic manipulation. Fourteen months after reduction, the joint was intact, muscle strength was graded +5 normal, ranges of motion were within normal limits and no crepitation was noted. X-rays revealed normal intact joint congruency. The patient experienced full weight bearing, range of motion and function of the joint. Although a Type III dislocation of the great toe has only once been cited briefly in the literature, this classification carries a recommended surgical treatment protocol for correction. No literature describes a closed reduction of a Type III dislocation as described in this case report. It is apparent that a closed reduction technique using a chiropractic manipulation may be considered a valid alternative correction technique for Type III dislocations of the great toe.

  4. Accurate 3D reconstruction of bony surfaces using ultrasonic synthetic aperture techniques for robotic knee arthroplasty.

    PubMed

    Kerr, William; Rowe, Philip; Pierce, Stephen Gareth

    2017-06-01

    Robotically guided knee arthroplasty systems generally require an individualized, preoperative 3D model of the knee joint. This is typically measured using Computed Tomography (CT) which provides the required accuracy for preoperative surgical intervention planning. Ultrasound imaging presents an attractive alternative to CT, allowing for reductions in cost and the elimination of doses of ionizing radiation, whilst maintaining the accuracy of the 3D model reconstruction of the joint. Traditional phased array ultrasound imaging methods, however, are susceptible to poor resolution and signal to noise ratios (SNR). Alleviating these weaknesses by offering superior focusing power, synthetic aperture methods have been investigated extensively within ultrasonic non-destructive testing. Despite this, they have yet to be fully exploited in medical imaging. In this paper, the ability of a robotic deployed ultrasound imaging system based on synthetic aperture methods to accurately reconstruct bony surfaces is investigated. Employing the Total Focussing Method (TFM) and the Synthetic Aperture Focussing Technique (SAFT), two samples were imaged which were representative of the bones of the knee joint: a human-shaped, composite distal femur and a bovine distal femur. Data were captured using a 5MHz, 128 element 1D phased array, which was manipulated around the samples using a robotic positioning system. Three dimensional surface reconstructions were then produced and compared with reference models measured using a precision laser scanner. Mean errors of 0.82mm and 0.88mm were obtained for the composite and bovine samples, respectively, thus demonstrating the feasibility of the approach to deliver the sub-millimetre accuracy required for the application. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Acute acromioclavicular dislocation: a cheaper, easier and all-arthroscopic system. Is it effective in nowadays economical crisis?

    PubMed

    Sastre, Sergi; Dada, Michelle; Santos, Simon; Lozano, Lluis; Alemany, Xavier; Peidro, Lluis

    2015-03-01

    The objective of this manuscript is to show an effective, easier and cheaper way to reduce acute acromioclavicular (AC) dislocation type III and V (Rockwood classification). Numerous procedures have been described for surgical management of acromioclavicular joint disruption. Newest devices involve an arthroscopic technique that allows nonrigid anatomic fixation of the acromioclavicular joint. Arthroscopically assisted treatment of acute AC joint dislocation is advantageous because it provides good clinical results and few complications. It also allows reviewing glenohumeral associated lesions. This surgical technique requires no specific implants to achieve a correct AC reduction. Actually, economical advantages are very important factors to decide the use of determinate surgical techniques.

  6. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    PubMed

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Analyzer-based imaging technique in tomography of cartilage and metal implants: a study at the ESRF

    PubMed Central

    COAN, Paola; MOLLENHAUER, Juergen; WAGNER, Andreas; Muehleman, Carol; BRAVIN, Alberto

    2009-01-01

    Monitoring the progression of osteoarthritis (OA) and the effects of therapy during clinical trials is still a challenge for present clinical imaging techniques since they present intrinsic limitations and can be sensitive only in case of advanced OA stages. In very severe cases, partial or complete joint replacement surgery is the only solution for reducing pain and restoring the joint functions. Poor imaging quality in practically all medical imaging technologies with respect to joint surfaces and to metal implant imaging calls for the development of new techniques that are sensitive to stages preceding the point of irreversible damage of the cartilage tissue. In this scenario, X-ray phase contrast modalities could play an important role since they can provide improved contrast compared to conventional absorption radiography, with a similar or even reduced tissue radiation dose. In this study, the Analyzer-based imaging (ABI), a technique sensitive to the X-ray refraction and permitting a high scatter rejection, has been successfully applied in-vitro on excised human synovial joints and sheep implants. Pathological and healthy joints as well as metal implants have been imaged in projection and computed tomography ABI mode at high resolution and clinically compatible doses (< 10 mGy). Volume rendering and segmentation permitted visualization of the cartilage from volumetric CT-scans. Results demonstrate that ABI can provide an unequivocal non-invasive diagnosis of the state of disease of the joint and be considered a new tool in orthopaedic research. PMID:18584983

  8. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

    PubMed

    Yoshida, H; Faust, A; Wilckens, J; Kitagawa, M; Fetto, J; Chao, Edmund Y-S

    2006-01-01

    Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.

  9. A Description for Rock Joint Roughness Based on Terrestrial Laser Scanner and Image Analysis

    PubMed Central

    Ge, Yunfeng; Tang, Huiming; Eldin, M. A. M Ez; Chen, Pengyu; Wang, Liangqing; Wang, Jinge

    2015-01-01

    Shear behavior of rock mass greatly depends upon the rock joint roughness which is generally characterized by anisotropy, scale effect and interval effect. A new index enabling to capture all the three features, namely brightness area percentage (BAP), is presented to express the roughness based on synthetic illumination of a digital terrain model derived from terrestrial laser scanner (TLS). Since only tiny planes facing opposite to shear direction make contribution to resistance during shear failure, therefore these planes are recognized through the image processing technique by taking advantage of the fact that they appear brighter than other ones under the same light source. Comparison with existing roughness indexes and two case studies were illustrated to test the performance of BAP description. The results reveal that the rock joint roughness estimated by the presented description has a good match with existing roughness methods and displays a wider applicability. PMID:26585247

  10. Composite SAR imaging using sequential joint sparsity

    NASA Astrophysics Data System (ADS)

    Sanders, Toby; Gelb, Anne; Platte, Rodrigo B.

    2017-06-01

    This paper investigates accurate and efficient ℓ1 regularization methods for generating synthetic aperture radar (SAR) images. Although ℓ1 regularization algorithms are already employed in SAR imaging, practical and efficient implementation in terms of real time imaging remain a challenge. Here we demonstrate that fast numerical operators can be used to robustly implement ℓ1 regularization methods that are as or more efficient than traditional approaches such as back projection, while providing superior image quality. In particular, we develop a sequential joint sparsity model for composite SAR imaging which naturally combines the joint sparsity methodology with composite SAR. Our technique, which can be implemented using standard, fractional, or higher order total variation regularization, is able to reduce the effects of speckle and other noisy artifacts with little additional computational cost. Finally we show that generalizing total variation regularization to non-integer and higher orders provides improved flexibility and robustness for SAR imaging.

  11. Identifying seawater intrusion in coastal areas by means of 1D and quasi-2D joint inversion of TDEM and VES data

    NASA Astrophysics Data System (ADS)

    Martínez-Moreno, F. J.; Monteiro-Santos, F. A.; Bernardo, I.; Farzamian, M.; Nascimento, C.; Fernandes, J.; Casal, B.; Ribeiro, J. A.

    2017-09-01

    Seawater intrusion is an increasingly widespread problem in coastal aquifers caused by climate changes -sea-level rise, extreme phenomena like flooding and droughts- and groundwater depletion near to the coastline. To evaluate and mitigate the environmental risks of this phenomenon it is necessary to characterize the coastal aquifer and the salt intrusion. Geophysical methods are the most appropriate tool to address these researches. Among all geophysical techniques, electrical methods are able to detect seawater intrusions due to the high resistivity contrast between saltwater, freshwater and geological layers. The combination of two or more geophysical methods is recommended and they are more efficient when both data are inverted jointly because the final model encompasses the physical properties measured for each methods. In this investigation, joint inversion of vertical electric and time domain soundings has been performed to examine seawater intrusion in an area within the Ferragudo-Albufeira aquifer system (Algarve, South of Portugal). For this purpose two profiles combining electrical resistivity tomography (ERT) and time domain electromagnetic (TDEM) methods were measured and the results were compared with the information obtained from exploration drilling. Three different inversions have been carried out: single inversion of the ERT and TDEM data, 1D joint inversion and quasi-2D joint inversion. Single inversion results identify seawater intrusion, although the sedimentary layers detected in exploration drilling were not well differentiated. The models obtained with 1D joint inversion improve the previous inversion due to better detection of sedimentary layer and the seawater intrusion appear to be better defined. Finally, the quasi-2D joint inversion reveals a more realistic shape of the seawater intrusion and it is able to distinguish more sedimentary layers recognised in the exploration drilling. This study demonstrates that the quasi-2D joint inversion improves the previous inversions methods making it a powerful tool applicable to different research areas.

  12. A Nonlinear Dynamics-Based Estimator for Functional Electrical Stimulation: Preliminary Results From Lower-Leg Extension Experiments.

    PubMed

    Allen, Marcus; Zhong, Qiang; Kirsch, Nicholas; Dani, Ashwin; Clark, William W; Sharma, Nitin

    2017-12-01

    Miniature inertial measurement units (IMUs) are wearable sensors that measure limb segment or joint angles during dynamic movements. However, IMUs are generally prone to drift, external magnetic interference, and measurement noise. This paper presents a new class of nonlinear state estimation technique called state-dependent coefficient (SDC) estimation to accurately predict joint angles from IMU measurements. The SDC estimation method uses limb dynamics, instead of limb kinematics, to estimate the limb state. Importantly, the nonlinear limb dynamic model is formulated into state-dependent matrices that facilitate the estimator design without performing a Jacobian linearization. The estimation method is experimentally demonstrated to predict knee joint angle measurements during functional electrical stimulation of the quadriceps muscle. The nonlinear knee musculoskeletal model was identified through a series of experiments. The SDC estimator was then compared with an extended kalman filter (EKF), which uses a Jacobian linearization and a rotation matrix method, which uses a kinematic model instead of the dynamic model. Each estimator's performance was evaluated against the true value of the joint angle, which was measured through a rotary encoder. The experimental results showed that the SDC estimator, the rotation matrix method, and EKF had root mean square errors of 2.70°, 2.86°, and 4.42°, respectively. Our preliminary experimental results show the new estimator's advantage over the EKF method but a slight advantage over the rotation matrix method. However, the information from the dynamic model allows the SDC method to use only one IMU to measure the knee angle compared with the rotation matrix method that uses two IMUs to estimate the angle.

  13. Microstructure Evolution and Mechanical Properties of Underwater Dry and Local Dry Cavity Welded Joints of 690 MPa Grade High Strength Steel

    PubMed Central

    Sun, Kun; Cui, Shuwan; Zeng, Min; Yi, Jianglong; Shen, Xiaoqin; Yi, Yaoyong

    2018-01-01

    Q690E high strength low alloy (HSLA) steel plays an important role in offshore structures. In addition, underwater local cavity welding (ULCW) technique was widely used to repair important offshore constructions. However, the high cooling rate of ULCW joints results in bad welding quality compared with underwater dry welding (UDW) joints. Q690E high strength low alloy steels were welded by multi-pass UDW and ULCW techniques, to study the microstructural evolution and mechanical properties of underwater welded joints. The microstructure and fracture morphology of welded joints were observed by scanning electron microscope and optical microscope. The elemental distribution in the microstructure was determined with an Electron Probe Microanalyzer. The results indicated that the microstructure of both two welded joints was similar. However, martensite and martensite-austenite components were significantly different with different underwater welding methods such that the micro-hardness of the HAZ and FZ in the ULCW specimen was higher than that of the corresponding regions in UDW joint. The yield strength and ultimate tensile strength of the ULCW specimen are 109 MPa lower and 77 MPa lower, respectively, than those of the UDW joint. The impact toughness of the UDW joint was superior to those of the ULCW joint. PMID:29361743

  14. Microstructure Evolution and Mechanical Properties of Underwater Dry and Local Dry Cavity Welded Joints of 690 MPa Grade High Strength Steel.

    PubMed

    Shi, Yonghua; Sun, Kun; Cui, Shuwan; Zeng, Min; Yi, Jianglong; Shen, Xiaoqin; Yi, Yaoyong

    2018-01-22

    Q690E high strength low alloy (HSLA) steel plays an important role in offshore structures. In addition, underwater local cavity welding (ULCW) technique was widely used to repair important offshore constructions. However, the high cooling rate of ULCW joints results in bad welding quality compared with underwater dry welding (UDW) joints. Q690E high strength low alloy steels were welded by multi-pass UDW and ULCW techniques, to study the microstructural evolution and mechanical properties of underwater welded joints. The microstructure and fracture morphology of welded joints were observed by scanning electron microscope and optical microscope. The elemental distribution in the microstructure was determined with an Electron Probe Microanalyzer. The results indicated that the microstructure of both two welded joints was similar. However, martensite and martensite-austenite components were significantly different with different underwater welding methods such that the micro-hardness of the HAZ and FZ in the ULCW specimen was higher than that of the corresponding regions in UDW joint. The yield strength and ultimate tensile strength of the ULCW specimen are 109 MPa lower and 77 MPa lower, respectively, than those of the UDW joint. The impact toughness of the UDW joint was superior to those of the ULCW joint.

  15. Determination of three-dimensional joint loading within the lower extremities in snowboarding.

    PubMed

    Krüger, Andreas; McAlpine, Paul; Borrani, Fabio; Edelmann-Nusser, Jürgen

    2012-02-01

    In the biomechanical literature only a few studies are available focusing on the determination of joint loading within the lower extremities in snowboarding. These studies are limited to analysis in a restricted capture volume due to the use of optical video-based systems. To overcome this restriction the aim of the present study was to develop a method to determine net joint moments within the lower extremities in snowboarding for complete measurement runs. An experienced snowboarder performed several runs equipped with two custom-made force plates as well as a full-body inertial measurement system. A rigid, multi-segment model was developed to describe the motion and loads within the lower extremities. This model is based on an existing lower-body model and designed to be run by the OpenSim software package. Measured kinetic and kinematic data were imported into the OpenSim program and inverse dynamic calculations were performed. The results illustrate the potential of the developed method for the determination of joint loadings within the lower extremities for complete measurement runs in a real snowboarding environment. The calculated net joint moments of force are reasonable in comparison to the data presented in the literature. A good reliability of the method seems to be indicated by the low data variation between different turns. Due to the unknown accuracy of this method the application for inter-individual studies as well as studies of injury mechanisms may be limited. For intra-individual studies comparing different snowboarding techniques as well as different snowboard equipment the method seems to be beneficial. The validity of the method needs to be studied further.

  16. First metatarsal-phalangeal joint arthrodesis: a biomechanical assessment of stability.

    PubMed

    Politi, Joel; John, Hayes; Njus, Glen; Bennett, Gordon L; Kay, David B

    2003-04-01

    First metatarsal phalangeal joint (MTP) arthrodesis is a commonly performed procedure for the treatment of hallux rigidus, severe and recurrent bunion deformities, rheumatoid arthritis and other less common disorders of the joint. There are different techniques of fixation of the joint to promote arthrodesis including oblique lag screw fixation, lag screw and dorsal plate fixation, crossed Kirschner wires, dorsal plate fixation alone and various types of external fixation. Ideally the fixation method should be reproducible, lead to a high rate of fusion, and have a low incidence of complications. In the present study, we compared the strength of fixation of five commonly utilized techniques of first MTP joint arthrodesis. These were: 1. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical interfragmentary lag screw. 2. Surface excision with machined conical reaming and fixation with crossed 0.062 Kirschner wires. 3. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical lag screw and a four hole dorsal miniplate secured with 3.5 mm cortical screws. 4. Surface excision with machined conical reaming and fixation with a four hole dorsal miniplate secured with 3.5 mm cortical screws and no lag screw. 5. Planar surface excision and fixation with a single oblique 3.5 mm interfragmentary cortical lag screw. Testing was done on an Instron materials testing device loading the first MTP joint in dorsiflexion. Liquid metal strain gauges were placed over the joint and micromotion was detected with varying loads and cycles. The most stable technique was the combination of machined conical reaming and an oblique interfragmentary lag screw and dorsal plate. This was greater than two times stronger than an oblique lag screw alone. Dorsal plate alone and Kirschner wire fixation were the weakest techniques. First MTP fusion is a commonly performed procedure for the treatment of a variety of disorders of the first MTP joint. The most stable technique for obtaining fusion in this study was the combination of an oblique lag screw and a dorsal plate. This should lead to higher rates of arthrodesis.

  17. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    PubMed

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  18. QUANTITATIVE MAGNETIC RESONANCE IMAGING OF ARTICULAR CARTILAGE AND ITS CLINICAL APPLICATIONS

    PubMed Central

    Li, Xiaojuan; Majumdar, Sharmila

    2013-01-01

    Cartilage is one of the most essential tissues for healthy joint function and is compromised in degenerative and traumatic joint diseases. There have been tremendous advances during the past decade using quantitative MRI techniques as a non-invasive tool for evaluating cartilage, with a focus on assessing cartilage degeneration during osteoarthritis (OA). In this review, after a brief overview of cartilage composition and degeneration, we discuss techniques that grade and quantify morphologic changes as well as the techniques that quantify changes in the extracellular matrix. The basic principles, in vivo applications, advantages and challenges for each technique are discussed. Recent studies using the OA Initiative (OAI) data are also summarized. Quantitative MRI provides non-invasive measures of cartilage degeneration at the earliest stages of joint degeneration, which is essential for efforts towards prevention and early intervention in OA. PMID:24115571

  19. Multilevel Latent Class Analysis for Large-Scale Educational Assessment Data: Exploring the Relation between the Curriculum and Students' Mathematical Strategies

    ERIC Educational Resources Information Center

    Fagginger Auer, Marije F.; Hickendorff, Marian; Van Putten, Cornelis M.; Béguin, Anton A.; Heiser, Willem J.

    2016-01-01

    A first application of multilevel latent class analysis (MLCA) to educational large-scale assessment data is demonstrated. This statistical technique addresses several of the challenges that assessment data offers. Importantly, MLCA allows modeling of the often ignored teacher effects and of the joint influence of teacher and student variables.…

  20. Masonry arches retrofitted with steel reinforced grout materials: In-situ experimental tests and advanced FE simulations

    NASA Astrophysics Data System (ADS)

    Bertolesi, Elisa; Carozzi, Francesca Giulia; Milani, Gabriele; Poggi, Carlo

    2017-11-01

    The paper presents the results of a series of in-situ tests carried out on two masonry arches, one unreinforced and the other reinforced with SRG (Steel Reinforced Grout). The arches are built adopting a peculiar construction technique using common Italian bricks with dimensions 250 × 120 × 55 mm3 and 10 mm thick mortar joints. One of the two arches has been reinforced with an SRG material constituted by an inox grid embedded into a layer of lime mortar, whereas the second one is maintained unreinforced for comparison purposes. The experimental set-up is designed to apply an eccentric vertical load placed at ¼ of the span in a series of loading and unloading cycles up to the failure. The numerical analyses have been performed using a sophisticated heterogeneous micro-modeling technique, where bricks, mortar joints and the strengthening have been modeled separately. Finally, the numerical outcomes have been comparatively assessed with respect to the experimental results and the crack patterns obtained at the end of the tests, showing a satisfactory agreement in terms of the global behavior of the arches and their collapse mechanisms.

  1. Mechanistic Prediction of the Effect of Microstructural Coarsening on Creep Response of SnAgCu Solder Joints

    NASA Astrophysics Data System (ADS)

    Mukherjee, S.; Chauhan, P.; Osterman, M.; Dasgupta, A.; Pecht, M.

    2016-07-01

    Mechanistic microstructural models have been developed to capture the effect of isothermal aging on time dependent viscoplastic response of Sn3.0Ag0.5Cu (SAC305) solders. SnAgCu (SAC) solders undergo continuous microstructural coarsening during both storage and service because of their high homologous temperature. The microstructures of these low melting point alloys continuously evolve during service. This results in evolution of creep properties of the joint over time, thereby influencing the long term reliability of microelectronic packages. It is well documented that isothermal aging degrades the creep resistance of SAC solder. SAC305 alloy is aged for (24-1000) h at (25-100)°C (~0.6-0.8 × T melt). Cross-sectioning and image processing techniques were used to periodically quantify the effect of isothermal aging on phase coarsening and evolution. The parameters monitored during isothermal aging include size, area fraction, and inter-particle spacing of nanoscale Ag3Sn intermetallic compounds (IMCs) and the volume fraction of micronscale Cu6Sn5 IMCs, as well as the area fraction of pure tin dendrites. Effects of microstructural evolution on secondary creep constitutive response of SAC305 solder joints were then modeled using a mechanistic multiscale creep model. The mechanistic phenomena modeled include: (1) dispersion strengthening by coarsened nanoscale Ag3Sn IMCs in the eutectic phase; and (2) load sharing between pro-eutectic Sn dendrites and the surrounding coarsened eutectic Sn-Ag phase and microscale Cu6Sn5 IMCs. The coarse-grained polycrystalline Sn microstructure in SAC305 solder was not captured in the above model because isothermal aging does not cause any significant change in the initial grain size and orientation of SAC305 solder joints. The above mechanistic model can successfully capture the drop in creep resistance due to the influence of isothermal aging on SAC305 single crystals. Contribution of grain boundary sliding to the creep strain of coarse grained joints has not been modeled in this study.

  2. Bayesian demosaicing using Gaussian scale mixture priors with local adaptivity in the dual tree complex wavelet packet transform domain

    NASA Astrophysics Data System (ADS)

    Goossens, Bart; Aelterman, Jan; Luong, Hiep; Pizurica, Aleksandra; Philips, Wilfried

    2013-02-01

    In digital cameras and mobile phones, there is an ongoing trend to increase the image resolution, decrease the sensor size and to use lower exposure times. Because smaller sensors inherently lead to more noise and a worse spatial resolution, digital post-processing techniques are required to resolve many of the artifacts. Color filter arrays (CFAs), which use alternating patterns of color filters, are very popular because of price and power consumption reasons. However, color filter arrays require the use of a post-processing technique such as demosaicing to recover full resolution RGB images. Recently, there has been some interest in techniques that jointly perform the demosaicing and denoising. This has the advantage that the demosaicing and denoising can be performed optimally (e.g. in the MSE sense) for the considered noise model, while avoiding artifacts introduced when using demosaicing and denoising sequentially. In this paper, we will continue the research line of the wavelet-based demosaicing techniques. These approaches are computationally simple and very suited for combination with denoising. Therefore, we will derive Bayesian Minimum Squared Error (MMSE) joint demosaicing and denoising rules in the complex wavelet packet domain, taking local adaptivity into account. As an image model, we will use Gaussian Scale Mixtures, thereby taking advantage of the directionality of the complex wavelets. Our results show that this technique is well capable of reconstructing fine details in the image, while removing all of the noise, at a relatively low computational cost. In particular, the complete reconstruction (including color correction, white balancing etc) of a 12 megapixel RAW image takes 3.5 sec on a recent mid-range GPU.

  3. Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures

    NASA Technical Reports Server (NTRS)

    Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini,Benjamin; Young, Daniel

    1990-01-01

    A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

  4. Calibrationless parallel magnetic resonance imaging: a joint sparsity model.

    PubMed

    Majumdar, Angshul; Chaudhury, Kunal Narayan; Ward, Rabab

    2013-12-05

    State-of-the-art parallel MRI techniques either explicitly or implicitly require certain parameters to be estimated, e.g., the sensitivity map for SENSE, SMASH and interpolation weights for GRAPPA, SPIRiT. Thus all these techniques are sensitive to the calibration (parameter estimation) stage. In this work, we have proposed a parallel MRI technique that does not require any calibration but yields reconstruction results that are at par with (or even better than) state-of-the-art methods in parallel MRI. Our proposed method required solving non-convex analysis and synthesis prior joint-sparsity problems. This work also derives the algorithms for solving them. Experimental validation was carried out on two datasets-eight channel brain and eight channel Shepp-Logan phantom. Two sampling methods were used-Variable Density Random sampling and non-Cartesian Radial sampling. For the brain data, acceleration factor of 4 was used and for the other an acceleration factor of 6 was used. The reconstruction results were quantitatively evaluated based on the Normalised Mean Squared Error between the reconstructed image and the originals. The qualitative evaluation was based on the actual reconstructed images. We compared our work with four state-of-the-art parallel imaging techniques; two calibrated methods-CS SENSE and l1SPIRiT and two calibration free techniques-Distributed CS and SAKE. Our method yields better reconstruction results than all of them.

  5. Soft tissue distraction using pentagonal frame for long-standing traumatic flexion deformity of interphalangeal joints.

    PubMed

    Nazerani, Shaharm; Keramati, Mohammad Reza; Vahedian, Jalal; Fereshtehnejad, Seyed-Mohammad

    2012-01-01

    Interphalangeal joint contracture is a challenging complication of hand trauma, which reduces the functional capacity of the entire hand. In this study we evaluated the results of soft tissue distraction with no collateral ligament transection or volar plate removal in comparison with traditional operation of contracture release and partial ligament transection and volar plate removal. In this prospective study, a total of 40 patients in two equal groups (A and B) were studied. Patients suffering from chronic flexion contracture of abrasive traumatic nature were included. Group A were treated by soft tissue distraction using pentagonal frame technique and in Group B the contracture release was followed by finger splinting. Analyzed data revealed a significant difference between the two groups for range of motion in the proximal interphalangeal joints (P less than 0.05), while it was not meaningful in the distal interphalangeal joints (P larger than 0.05). There was not a significant difference in the degrees of flexion contracture between groups (P larger than 0.05). Regression analysis showed that using pentagonal frame technique significantly increased the mean improvement in range of motion of proximal interphalangeal joints (P less than 0.001), while the higher the preoperative flexion contracture was observed in proximal interphalangeal joints, the lower improvement was achieved in range of motion of proximal interphalangeal joints after intervention (P less than 0.001). Soft tissue distraction using pentagonal frame technique with gradual and continuous collateral ligament and surrounding joint tissues distraction combined with skin Z-plasty significantly improves the range of motion in patients with chronic traumatic flexion deformity of proximal and/or distal interphalangeal joints.

  6. Periodontal Ligament Entheses and their Adaptive Role in the Context of Dentoalveolar Joint Function

    PubMed Central

    Lin, Jeremy D.; Jang, Andrew T.; Kurylo, Michael P.; Hurng, Jonathan; Yang, Feifei; Yang, Lynn; Pal, Arvin; Chen, Ling; Ho, Sunita P.

    2017-01-01

    Objectives The dynamic bone-periodontal ligament (PDL)-tooth fibrous joint consists of two adaptive functionally graded interfaces (FGI), the PDL-bone and PDL-cementum that respond to mechanical strain transmitted during mastication. In general, from a materials and mechanics perspective, FGI prevent catastrophic failure during prolonged cyclic loading. This review is a discourse of results gathered from literature to illustrate the dynamic adaptive nature of the fibrous joint in response to physiologic and pathologic simulated functions, and experimental tooth movement. Methods Historically, studies have investigated soft to hard tissue transitions through analytical techniques that provided insights into structural, biochemical, and mechanical characterization methods. Experimental approaches included two dimensional to three dimensional advanced in situ imaging and analytical techniques. These techniques allowed mapping and correlation of deformations to physicochemical and mechanobiological changes within volumes of the complex subjected to concentric and eccentric loading regimes respectively. Results Tooth movement is facilitated by mechanobiological activity at the interfaces of the fibrous joint and generates elastic discontinuities at these interfaces in response to eccentric loading. Both concentric and eccentric loads mediated cellular responses to strains, and prompted self-regulating mineral forming and resorbing zones that in turn altered the functional space of the joint. Significance A multiscale biomechanics and mechanobiology approach is important for correlating joint function to tissue-level strain-adaptive properties with overall effects on joint form as related to physiologic and pathologic functions. Elucidating the shift in localization of biomolecules specifically at interfaces during development, function, and therapeutic loading of the joint is critical for developing “functional regeneration and adaptation” strategies with an emphasis on restoring physiologic joint function. PMID:28476202

  7. Spent Fuel Test-Climax: core logging for site investigation and instrumentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilder, D.G.; Yow, J.L. Jr.; Thorpe, R.K.

    1982-05-28

    As an integral part of the Spent Fuel Test-Climax 5150 ft (1570 m) of granite core was obtained. This core was diamond drilled in various sizes, mainly 38-mm and 76-mm diameters. The core was teken with single tube core barrels and was unoriented. Techniques used to drill and log this core are discussed, as well as techniques to orient the core. Of the 5150 ft (1570 m) of core more than 3645 ft (1111 m) was retained and logged in some detail. As a result of the core logging, geologic discontinuities were identified, joint frequency and spacing characterized. Discontinuities identifiedmore » included several joint sets, shear zones and faults. Correlations based on coring along were generally found to be impossible, even for the more prominent features. The only feature properly correlated from the exploratory drilling was the fault system at the end of the facility, but it was not identified from the exploratory core as a fault. Identification of discontinuities was later helped by underground mapping that identified several different joint sets with different characteristics. It was found that joint frequency varied from 0.3 to 1.1 joint per foot of core for open fractures and from 0.3 to 3.3/ft for closed or healed fractures. Histograms of fracture spacing indicate that there is likely a random distribution of spacing superimposed upon uniformly spaced fractures. It was found that a low angle joint set had a persistent mean orientation. These joints were healed and had pervasive wall rock alteration which made identification of joints in this set possible. The recognition of a joint set with known attitude allowed orientation of much of the core. This orientation technique was found to be effective. 10 references, 25 figures, 4 tables.« less

  8. Environmental cold exposure increases blood flow and affects pain sensitivity in the knee joints of CFA-induced arthritic mice in a TRPA1-dependent manner.

    PubMed

    Fernandes, Elizabeth S; Russell, Fiona A; Alawi, Khadija M; Sand, Claire; Liang, Lihuan; Salamon, Robin; Bodkin, Jennifer V; Aubdool, Aisah A; Arno, Matthew; Gentry, Clive; Smillie, Sarah-Jane; Bevan, Stuart; Keeble, Julie E; Malcangio, Marzia; Brain, Susan D

    2016-01-11

    The effect of cold temperature on arthritis symptoms is unclear. The aim of this study was to investigate how environmental cold affects pain and blood flow in mono-arthritic mice, and examine a role for transient receptor potential ankyrin 1 (TRPA1), a ligand-gated cation channel that can act as a cold sensor. Mono-arthritis was induced by unilateral intra-articular injection of complete Freund's adjuvant (CFA) in CD1 mice, and in mice either lacking TRPA1 (TRPA1 KO) or respective wildtypes (WT). Two weeks later, nociception and joint blood flow were measured following exposure to 10 °C (1 h) or room temperature (RT). Primary mechanical hyperalgesia in the knee was measured by pressure application apparatus; secondary mechanical hyperalgesia by automated von Frey system; thermal hyperalgesia by Hargreaves technique, and weight bearing by the incapacitance test. Joint blood flow was recorded by full-field laser perfusion imager (FLPI) and using clearance of (99m)Technetium. Blood flow was assessed after pretreatment with antagonists of either TRPA1 (HC-030031), substance P neurokinin 1 (NK1) receptors (SR140333) or calcitonin gene-related peptide (CGRP) (CGRP8-37). TRPA1, TAC-1 and CGRP mRNA levels were examined in dorsal root ganglia, synovial membrane and patellar cartilage samples. Cold exposure caused bilateral primary mechanical hyperalgesia 2 weeks after CFA injection, in a TRPA1-dependent manner. In animals maintained at RT, clearance techniques and FLPI showed that CFA-treated joints exhibited lower blood flow than saline-treated joints. In cold-exposed animals, this reduction in blood flow disappears, and increased blood flow in the CFA-treated joint is observed using FLPI. Cold-induced increased blood flow in CFA-treated joints was blocked by HC-030031 and not observed in TRPA1 KOs. Cold exposure increased TRPA1 mRNA levels in patellar cartilage, whilst reducing it in synovial membranes from CFA-treated joints. We provide evidence that environmental cold exposure enhances pain and increases blood flow in a mono-arthritis model. These changes are dependent on TRPA1. Thus, TRPA1 may act locally within the joint to influence blood flow via sensory nerves, in addition to its established nociceptive actions.

  9. Modeling of the Nonlinear Interface in Reinforced Concrete

    NASA Astrophysics Data System (ADS)

    Curiel Sosa, J. L.

    2010-04-01

    This article presents a novel scheme for modeling of reinforced concrete. The strategy takes into account the nonlinear behavior of the concrete as well as the debonding in the interface. The proposed technique solves the kinematic and kinetic jump in the interface by performing sub-cycles over the constituents-reinforcing bar and concrete-jointly with an innovative interface constitutive law. Application to pull-out problems is performed to show the capabilities of the proposed methodology by means of comparison with available experimental data.

  10. Robust stability of second-order systems

    NASA Technical Reports Server (NTRS)

    Chuang, C.-H.

    1993-01-01

    A feedback linearization technique is used in conjunction with passivity concepts to design robust controllers for space robots. It is assumed that bounded modeling uncertainties exist in the inertia matrix and the vector representing the coriolis, centripetal, and friction forces. Under these assumptions, the controller guarantees asymptotic tracking of the joint variables. A Lagrangian approach is used to develop a dynamic model for space robots. Closed-loop simulation results are illustrated for a simple case of a single link planar manipulator with freely floating base.

  11. Supervised Gamma Process Poisson Factorization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Dylan Zachary

    This thesis develops the supervised gamma process Poisson factorization (S- GPPF) framework, a novel supervised topic model for joint modeling of count matrices and document labels. S-GPPF is fully generative and nonparametric: document labels and count matrices are modeled under a uni ed probabilistic framework and the number of latent topics is controlled automatically via a gamma process prior. The framework provides for multi-class classification of documents using a generative max-margin classifier. Several recent data augmentation techniques are leveraged to provide for exact inference using a Gibbs sampling scheme. The first portion of this thesis reviews supervised topic modeling andmore » several key mathematical devices used in the formulation of S-GPPF. The thesis then introduces the S-GPPF generative model and derives the conditional posterior distributions of the latent variables for posterior inference via Gibbs sampling. The S-GPPF is shown to exhibit state-of-the-art performance for joint topic modeling and document classification on a dataset of conference abstracts, beating out competing supervised topic models. The unique properties of S-GPPF along with its competitive performance make it a novel contribution to supervised topic modeling.« less

  12. Real-time estimation of FES-induced joint torque with evoked EMG : Application to spinal cord injured patients.

    PubMed

    Li, Zhan; Guiraud, David; Andreu, David; Benoussaad, Mourad; Fattal, Charles; Hayashibe, Mitsuhiro

    2016-06-22

    Functional electrical stimulation (FES) is a neuroprosthetic technique for restoring lost motor function of spinal cord injured (SCI) patients and motor-impaired subjects by delivering short electrical pulses to their paralyzed muscles or motor nerves. FES induces action potentials respectively on muscles or nerves so that muscle activity can be characterized by the synchronous recruitment of motor units with its compound electromyography (EMG) signal is called M-wave. The recorded evoked EMG (eEMG) can be employed to predict the resultant joint torque, and modeling of FES-induced joint torque based on eEMG is an essential step to provide necessary prediction of the expected muscle response before achieving accurate joint torque control by FES. Previous works on FES-induced torque tracking issues were mainly based on offline analysis. However, toward personalized clinical rehabilitation applications, real-time FES systems are essentially required considering the subject-specific muscle responses against electrical stimulation. This paper proposes a wireless portable stimulator used for estimating/predicting joint torque based on real time processing of eEMG. Kalman filter and recurrent neural network (RNN) are embedded into the real-time FES system for identification and estimation. Prediction results on 3 able-bodied subjects and 3 SCI patients demonstrate promising performances. As estimators, both Kalman filter and RNN approaches show clinically feasible results on estimation/prediction of joint torque with eEMG signals only, moreover RNN requires less computational requirement. The proposed real-time FES system establishes a platform for estimating and assessing the mechanical output, the electromyographic recordings and associated models. It will contribute to open a new modality for personalized portable neuroprosthetic control toward consolidated personal healthcare for motor-impaired patients.

  13. A Comparative Study of Co-Channel Interference Suppression Techniques

    NASA Technical Reports Server (NTRS)

    Hamkins, Jon; Satorius, Ed; Paparisto, Gent; Polydoros, Andreas

    1997-01-01

    We describe three methods of combatting co-channel interference (CCI): a cross-coupled phase-locked loop (CCPLL); a phase-tracking circuit (PTC), and joint Viterbi estimation based on the maximum likelihood principle. In the case of co-channel FM-modulated voice signals, the CCPLL and PTC methods typically outperform the maximum likelihood estimators when the modulation parameters are dissimilar. However, as the modulation parameters become identical, joint Viterbi estimation provides for a more robust estimate of the co-channel signals and does not suffer as much from "signal switching" which especially plagues the CCPLL approach. Good performance for the PTC requires both dissimilar modulation parameters and a priori knowledge of the co-channel signal amplitudes. The CCPLL and joint Viterbi estimators, on the other hand, incorporate accurate amplitude estimates. In addition, application of the joint Viterbi algorithm to demodulating co-channel digital (BPSK) signals in a multipath environment is also discussed. It is shown in this case that if the interference is sufficiently small, a single trellis model is most effective in demodulating the co-channel signals.

  14. Registration of knee joint surfaces for the in vivo study of joint injuries based on magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Cheng, Rita W. T.; Habib, Ayman F.; Frayne, Richard; Ronsky, Janet L.

    2006-03-01

    In-vivo quantitative assessments of joint conditions and health status can help to increase understanding of the pathology of osteoarthritis, a degenerative joint disease that affects a large population each year. Magnetic resonance imaging (MRI) provides a non-invasive and accurate means to assess and monitor joint properties, and has become widely used for diagnosis and biomechanics studies. Quantitative analyses and comparisons of MR datasets require accurate alignment of anatomical structures, thus image registration becomes a necessary procedure for these applications. This research focuses on developing a registration technique for MR knee joint surfaces to allow quantitative study of joint injuries and health status. It introduces a novel idea of translating techniques originally developed for geographic data in the field of photogrammetry and remote sensing to register 3D MR data. The proposed algorithm works with surfaces that are represented by randomly distributed points with no requirement of known correspondences. The algorithm performs matching locally by identifying corresponding surface elements, and solves for the transformation parameters relating the surfaces by minimizing normal distances between them. This technique was used in three applications to: 1) register temporal MR data to verify the feasibility of the algorithm to help monitor diseases, 2) quantify patellar movement with respect to the femur based on the transformation parameters, and 3) quantify changes in contact area locations between the patellar and femoral cartilage at different knee flexion angles. The results indicate accurate registration and the proposed algorithm can be applied for in-vivo study of joint injuries with MRI.

  15. An automatic 2D–3D image matching method for reproducing spatial knee joint positions using single or dual fluoroscopic images

    PubMed Central

    Zhu, Zhonglin; Li, Guoan

    2013-01-01

    Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D–3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.28 in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions. PMID:21806411

  16. Joint temporal density measurements for two-photon state characterization.

    PubMed

    Kuzucu, Onur; Wong, Franco N C; Kurimura, Sunao; Tovstonog, Sergey

    2008-10-10

    We demonstrate a technique for characterizing two-photon quantum states based on joint temporal correlation measurements using time-resolved single-photon detection by femtosecond up-conversion. We measure for the first time the joint temporal density of a two-photon entangled state, showing clearly the time anticorrelation of the coincident-frequency entangled photon pair generated by ultrafast spontaneous parametric down-conversion under extended phase-matching conditions. The new technique enables us to manipulate the frequency entanglement by varying the down-conversion pump bandwidth to produce a nearly unentangled two-photon state that is expected to yield a heralded single-photon state with a purity of 0.88. The time-domain correlation technique complements existing frequency-domain measurement methods for a more complete characterization of photonic entanglement.

  17. Bone Repair and Military Readiness

    DTIC Science & Technology

    2012-10-25

    formation. Orthopedic surgeons have had to adapt surgical techniques to account for issues with cementing total joint prostheses and subsequent total joint ...the silorane composite has the potential to support osseous integration around the cemented total joint implant and may generate less immunogenic wear...factors, and potential for osseointegration/osseoinduction, this material has potential to be used for screw augmentation, total hip/knee joint

  18. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    PubMed

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as < 50%, 50 - 80%, and > 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially confounded. Compared to the cooled radiofrequency ablation (c-RFA) technique, the new b-RFA technique reduced operating time by more than 50%, decreased x-ray exposure by more than 80%, and cut the cost by more than $1000 per case. The new method was associated with significantly improved clinical outcomes despite the limitations of the study design. Thus this new technique appeared to be safe, efficacious, and cost-effective. Key words: Sacroiliac joint pain, sacroiliac joint, low back pain, radiofrequency ablation (RFA), bipolar radiofrequency ablation (b-RFA), cooled radiofrequency ablation (c-RFA), cost-effectiveness.

  19. Contraction Sensing with Smart Braid McKibben Muscles

    PubMed Central

    Felt, Wyatt; Chin, Khai Yi; Remy, C. David

    2016-01-01

    The inherent compliance of soft fluidic actuators makes them attractive for use in wearable devices and soft robotics. Their flexible nature permits them to be used without traditional rotational or prismatic joints. Without these joints, however, measuring the motion of the actuators is challenging. Actuator-level sensors could improve the performance of continuum robots and robots with compliant or multi-degree-of-freedom joints. We make the reinforcing braid of a pneumatic artificial muscle (PAM or McKibben muscle) “smart” by weaving it from conductive, insulated wires. These wires form a solenoid-like circuit with an inductance that more than doubles over the PAM contraction. The reinforcing and sensing fibers can be used to measure the contraction of a PAM actuator with a simple, linear function of the measured inductance. Whereas other proposed self-sensing techniques rely on the addition of special elastomers or transducers, the technique presented in this work can be implemented without modifications of this kind. We present and experimentally validate two models for Smart Braid sensors based on the long solenoid approximation and the Neumann formula, respectively. We test a McKibben muscle made from a Smart Braid in quasistatic conditions with various end-loads and in dynamic conditions. We also test the performance of the Smart Braid sensor alongside steel. PMID:28503062

  20. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis.

    PubMed

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-09-01

    This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (-0.09 mm, 95% confidence interval [CI]: -0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: -1.01 to -0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on the biomechanics of the knee joint. This suggests that the gap balancing and measured resection techniques are not mutually exclusive.

  1. A Modelling Method of Bolt Joints Based on Basic Characteristic Parameters of Joint Surfaces

    NASA Astrophysics Data System (ADS)

    Yuansheng, Li; Guangpeng, Zhang; Zhen, Zhang; Ping, Wang

    2018-02-01

    Bolt joints are common in machine tools and have a direct impact on the overall performance of the tools. Therefore, the understanding of bolt joint characteristics is essential for improving machine design and assembly. Firstly, According to the experimental data obtained from the experiment, the stiffness curve formula was fitted. Secondly, a finite element model of unit bolt joints such as bolt flange joints, bolt head joints, and thread joints was constructed, and lastly the stiffness parameters of joint surfaces were implemented in the model by the secondary development of ABAQUS. The finite element model of the bolt joint established by this method can simulate the contact state very well.

  2. Inverse dynamics of a 3 degree of freedom spatial flexible manipulator

    NASA Technical Reports Server (NTRS)

    Bayo, Eduardo; Serna, M.

    1989-01-01

    A technique is presented for solving the inverse dynamics and kinematics of 3 degree of freedom spatial flexible manipulator. The proposed method finds the joint torques necessary to produce a specified end effector motion. Since the inverse dynamic problem in elastic manipulators is closely coupled to the inverse kinematic problem, the solution of the first also renders the displacements and rotations at any point of the manipulator, including the joints. Furthermore the formulation is complete in the sense that it includes all the nonlinear terms due to the large rotation of the links. The Timoshenko beam theory is used to model the elastic characteristics, and the resulting equations of motion are discretized using the finite element method. An iterative solution scheme is proposed that relies on local linearization of the problem. The solution of each linearization is carried out in the frequency domain. The performance and capabilities of this technique are tested through simulation analysis. Results show the potential use of this method for the smooth motion control of space telerobots.

  3. Joint spectral characterization of photon-pair sources

    NASA Astrophysics Data System (ADS)

    Zielnicki, Kevin; Garay-Palmett, Karina; Cruz-Delgado, Daniel; Cruz-Ramirez, Hector; O'Boyle, Michael F.; Fang, Bin; Lorenz, Virginia O.; U'Ren, Alfred B.; Kwiat, Paul G.

    2018-06-01

    The ability to determine the joint spectral properties of photon pairs produced by the processes of spontaneous parametric downconversion (SPDC) and spontaneous four-wave mixing (SFWM) is crucial for guaranteeing the usability of heralded single photons and polarization-entangled pairs for multi-photon protocols. In this paper, we compare six different techniques that yield either a characterization of the joint spectral intensity or of the closely related purity of heralded single photons. These six techniques include: (i) scanning monochromator measurements, (ii) a variant of Fourier transform spectroscopy designed to extract the desired information exploiting a resource-optimized technique, (iii) dispersive fibre spectroscopy, (iv) stimulated-emission-based measurement, (v) measurement of the second-order correlation function ? for one of the two photons, and (vi) two-source Hong-Ou-Mandel interferometry. We discuss the relative performance of these techniques for the specific cases of a SPDC source designed to be factorable and SFWM sources of varying purity, and compare the techniques' relative advantages and disadvantages.

  4. Repair and tissue engineering techniques for articular cartilage.

    PubMed

    Makris, Eleftherios A; Gomoll, Andreas H; Malizos, Konstantinos N; Hu, Jerry C; Athanasiou, Kyriacos A

    2015-01-01

    Chondral and osteochondral lesions due to injury or other pathology commonly result in the development of osteoarthritis, eventually leading to progressive total joint destruction. Although current progress suggests that biologic agents can delay the advancement of deterioration, such drugs are incapable of promoting tissue restoration. The limited ability of articular cartilage to regenerate renders joint arthroplasty an unavoidable surgical intervention. This Review describes current, widely used clinical repair techniques for resurfacing articular cartilage defects; short-term and long-term clinical outcomes of these techniques are discussed. Also reviewed is a developmental pipeline of acellular and cellular regenerative products and techniques that could revolutionize joint care over the next decade by promoting the development of functional articular cartilage. Acellular products typically consist of collagen or hyaluronic-acid-based materials, whereas cellular techniques use either primary cells or stem cells, with or without scaffolds. Central to these efforts is the prominent role that tissue engineering has in translating biological technology into clinical products; therefore, concomitant regulatory processes are also discussed.

  5. Dynamic analysis of clamp band joint system subjected to axial vibration

    NASA Astrophysics Data System (ADS)

    Qin, Z. Y.; Yan, S. Z.; Chu, F. L.

    2010-10-01

    Clamp band joints are commonly used for connecting circular components together in industry. Some of the systems jointed by clamp band are subjected to dynamic load. However, very little research on the dynamic characteristics for this kind of joint can be found in the literature. In this paper, a dynamic model for clamp band joint system is developed. Contact and frictional slip between the components are accommodated in this model. Nonlinear finite element analysis is conducted to identify the model parameters. Then static experiments are carried out on a scaled model of the clamp band joint to validate the joint model. Finally, the model is adopted to study the dynamic characteristics of the clamp band joint system subjected to axial harmonic excitation and the effects of the wedge angle of the clamp band joint and the preload on the response. The model proposed in this paper can represent the nonlinearity of the clamp band joint and be used conveniently to investigate the effects of the structural and loading parameters on the dynamic characteristics of this type of joint system.

  6. Coracoid bypass procedure: surgical technique for coracoclavicular reconstruction with coracoid insufficiency.

    PubMed

    Virk, Mandeep S; Lederman, Evan; Stevens, Christopher; Romeo, Anthony A

    2017-04-01

    Failed acromioclavicular (AC) joint reconstruction secondary to a coracoid fracture or insufficiency of the coracoid is an uncommon but challenging clinical situation. We describe a surgical technique of revision coracoclavicular (CC) reconstruction, the coracoid bypass procedure, and report short-term results with this technique in 3 patients. In the coracoid bypass procedure, reconstruction of the CC ligaments is performed by passing a tendon graft through a surgically created bone tunnel in the scapular body (inferior to the base of the coracoid) and then fixing the graft around the clavicle or through bone tunnels in the clavicle. Three patients treated with this technique were retrospectively reviewed. AC joint reconstruction performed for a traumatic AC joint separation failed in the 3 patients reported in this series. The previous procedures were an anatomic CC reconstruction in 2 patients and a modified Weaver-Dunn procedure in 1 patient. The coracoid fractures were detected postoperatively, and the mean interval from the index surgery to the coracoid bypass procedure was 8 months. The patients were a mean age of 44 years, and average follow-up was 21 months. At the last follow-up, all 3 patients were pain free, with full range of shoulder motion, preserved CC distance, and a stable AC joint. The coracoid bypass procedure is a treatment option for CC joint reconstruction during revision AC joint surgery in the setting of a coracoid fracture or coracoid insufficiency. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Relation between hardness and ultrasonic velocity on pipeline steel welded joints

    NASA Astrophysics Data System (ADS)

    Carreón, H.; Barrera, G.; Natividad, C.; Salazar, M.; Contreras, A.

    2016-04-01

    In general, the ultrasonic techniques have been used to determine the mechanical properties of materials based on their relationship with metallurgical characteristics. In this research work, the relationship between ultrasonic wave velocity, hardness and the microstructure of steel pipeline welded joints is investigated. Measurements of ultrasonic wave velocity were made as a function of the location across the weld. Hardness measurements were performed in an attempt to correlate with ultrasonic response. In addition, the coarse and dendritic grain structure of the weld material is extreme and unpredictably anisotropic. Thus, due to the acoustic anisotropy of the crystal, weld material of studied joints is anisotropic too. Such structure is no longer direction-independent to the ultrasonic wave propagation; therefore, the ultrasonic beam deflects and redirects and the wave front becomes distorted. Thus, the use of conventional ultrasonic testing techniques using fixed beam angles is very limited and the application of conventional ultrasonic phased array techniques becomes desirable. This technique is proposed to assist pipeline operators in estimating the hardness through ultrasonic measures to evaluate the susceptibility to stress sulphide cracking and hydrogen-induced cracking due to hard spots in steel pipeline welded joints in service. Sound wave velocity and hardness measurements have been carried out on a steel welded joint. For each section of the welding, weld bead, fusion zone, heat affected zone and base metal were found to correspond particular values of the ultrasound velocity. These results were correlated with electron microscopy observations of the microstructure and sectorial scan view of welded joints by ultrasonic phased array.

  8. Characterization of the surface and interfacial properties of the lamina splendens

    NASA Astrophysics Data System (ADS)

    Rexwinkle, Joe T.; Hunt, Heather K.; Pfeiffer, Ferris M.

    2017-06-01

    Joint disease affects approximately 52.5 million patients in the United States alone, costing 80.8 billion USD in direct healthcare costs. The development of treatment programs for joint disease and trauma requires accurate assessment of articular cartilage degradation. The articular cartilage is the interfacial tissue between articulating surfaces, such as bones, and acts as low-friction interfaces. Damage to the lamina splendens, which is the articular cartilage's topmost layer, is an early indicator of joint degradation caused by injury or disease. By gaining comprehensive knowledge on the lamina splendens, particularly its structure and interfacial properties, researchers could enhance the accuracy of human and animal biomechanical models, as well as develop appropriate biomimetic materials for replacing damaged articular cartilage, thereby leading to rational treatment programs for joint disease and injury. Previous studies that utilize light, electron, and force microscopy techniques have found that the lamina splendens is composed of collagen fibers oriented parallel to the cartilage surface and encased in a proteoglycan matrix. Such orientation maximizes wear resistance and proteoglycan retention while promoting the passage of nutrients and synovial fluid. Although the structure of the lamina splendens has been explored in the literature, the low-friction interface of this tissue remains only partially characterized. Various functional models are currently available for the interface, such as pure boundary lubrication, thin films exuded under pressure, and sheets of trapped proteins. Recent studies suggest that each of these lubrication models has certain advantages over one another. Further research is needed to fully model the interface of this tissue. In this review, we summarize the methods for characterizing the lamina splendens and the results of each method. This paper aims to serve as a resource for existing studies to date and a roadmap of the investigations needed to gain further insight into the lamina splendens and the progression of joint disease.

  9. A practical guide for performing arthrography under fluoroscopic or ultrasound guidance.

    PubMed

    Lungu, Eugen; Moser, Thomas P

    2015-12-01

    We propose a practical approach for performing arthrography with fluoroscopic or ultrasound guidance. Different approaches to the principal joints of the upper limb (shoulder, elbow, wrist and fingers), lower limb (hip, knee, ankle and foot) as well as the facet joints of the spine are discussed and illustrated with numerous drawings. Whenever possible, we emphasise the concept of targeting articular recesses, which offers many advantages over traditional techniques aiming at the joint space. • Arthrography remains a foremost technique in musculoskeletal radiology • Most joints can be successfully accessed by targeting the articular recess • Targeting the recess offers several advantages over traditional approaches • Ultrasound-guidance is now favoured over fluoroscopy and targeting the recess is equally applicable.

  10. Management of Chronic Recurrent Dislocation of Temporomandibular Joint Using 'U' Shaped Graft: A New Restrictive Technique.

    PubMed

    Gadre, Kiran; Singh, Divya; Gadre, Pushkar; Halli, Rajshekhar

    2017-06-01

    Numerous procedures have been described for the treatment of chronic recurrent dislocation of the temporo-mandibular joint (TMJ), either in the form of enhancement or restriction of the condylar movement, with their obvious merits and demerits. We present a new technique of using U shaped iliac bone graft to restrict the condylar movement and its advantages over the conventional techniques.We have used this technique successfully in 8 cases where Dautrey's procedure had failed with follow up period of 2 years. No patient complained of recurrent dislocation postoperatively. This a very simple and effective technique where other procedures have failed.

  11. Treating the Proximal Interphalangeal Joint in Swan Neck and Boutonniere Deformities.

    PubMed

    Fox, Paige M; Chang, James

    2018-05-01

    Swan neck and boutonniere deformities of the proximal interphalangeal (PIP) joint are challenging to treat. In a swan neck deformity, the PIP joint is hyperextended with flexion at the distal interphalangeal (DIP) joint. In a boutonniere deformity, there is flexion the PIP joint with hyperextension of the DIP joint. When the deformities are flexible, treatment begins with splinting. However, when the deformity is fixed, serial casting or surgery is often necessary to restore joint motion before surgical correction. Many surgical techniques have been described to treat both conditions. Unfortunately, incomplete correction and deformity recurrence are common. Published by Elsevier Inc.

  12. Characterization of Nitinol Laser-Weld Joints by Nondestructive Testing

    NASA Astrophysics Data System (ADS)

    Wohlschlögel, Markus; Gläßel, Gunter; Sanchez, Daniela; Schüßler, Andreas; Dillenz, Alexander; Saal, David; Mayr, Peter

    2015-12-01

    Joining technology is an integral part of today's Nitinol medical device manufacturing. Besides crimping and riveting, laser welding is often applied to join components made from Nitinol to Nitinol, as well as Nitinol components to dissimilar materials. Other Nitinol joining techniques include adhesive bonding, soldering, and brazing. Typically, the performance of joints is assessed by destructive mechanical testing, on a process validation base. In this study, a nondestructive testing method—photothermal radiometry—is applied to characterize small Nitinol laser-weld joints used to connect two wire ends via a sleeve. Two different wire diameters are investigated. Effective joint connection cross sections are visualized using metallography techniques. Results of the nondestructive testing are correlated to data from destructive torsion testing, where the maximum torque at fracture is evaluated for the same joints and criteria for the differentiation of good and poor laser-welding quality by nondestructive testing are established.

  13. Arthroscopic fixation of acute acromioclavicular joint disruption with TightRope™: Outcome and complications after minimum 2 (2-5) years follow-up.

    PubMed

    Zhang, Li-Feng; Yin, Bo; Hou, Su; Han, Bing; Huang, De-Fa

    2017-01-01

    To evaluate the midterm results of arthroscopic reconstruction of acute acromioclavicular (AC) joint disruption using TightRope™ system. We retrospectively assess the results of 24 patients of acute AC joint dislocation who were operated using TightRope system. Constant and University of California, Los Angeles (UCLA) scores and coracoclavicular distance were calculated pre- and postoperatively. Data was entered into MS excel and analyzed using the SPSS version 17. The mean follow-up was 39.45 months. Constant and UCLA scores were significantly increased postoperatively. Six patients had partial loss of reduction within 3-6 months and two patients had a failure of construct. Constant score was significantly lower in these patients. TightRope reconstruction of the AC joint is a reproducible and safe alternative to many other techniques of AC joint reconstruction. Early subluxation remains a concern and may reflect the need for technique modification.

  14. Optimization and Characterization of the Friction Stir Welded Sheets of AA 5754-H111: Monitoring of the Quality of Joints with Thermographic Techniques.

    PubMed

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Palumbo, Davide; De Finis, Rosa; Galietti, Umberto

    2017-10-11

    Friction Stir Welding (FSW) is a solid-state welding process, based on frictional and stirring phenomena, that offers many advantages with respect to the traditional welding methods. However, several parameters can affect the quality of the produced joints. In this work, an experimental approach has been used for studying and optimizing the FSW process, applied on 5754-H111 aluminum plates. In particular, the thermal behavior of the material during the process has been investigated and two thermal indexes, the maximum temperature and the heating rate of the material, correlated to the frictional power input, were investigated for different process parameters (the travel and rotation tool speeds) configurations. Moreover, other techniques (micrographs, macrographs and destructive tensile tests) were carried out for supporting in a quantitative way the analysis of the quality of welded joints. The potential of thermographic technique has been demonstrated both for monitoring the FSW process and for predicting the quality of joints in terms of tensile strength.

  15. Apollonius of Citium (first century BC) and his work on the treatment of joint dislocations.

    PubMed

    Markatos, Konstantinos; Korres, Demetrios; Chytas, Demetrios; Karamanou, Marianna; Sourlas, Ioannis; Androutsos, Georgios; Mavrogenis, Andreas

    2018-05-01

    The purpose of this study was to summarise the life and work of the Cypriot physician Apollonius of Citium (first century BC). His overall work on medicine is presented, and special emphasis is given to his work on the treatment of joint dislocations. The most famous work of Apollonius is Treatise On Joints, which was preserved on the whole in a manuscript of the tenth century AD. In that manuscript, Apollonius is obviously influenced by the Hippocratic Corpus of Medicine. His description, diagnostic methods and reduction techniques are all based on those described by Hippocrates in his work "On Joints". Apollonius' contribution to this subject concerns accurate depiction in images of the reduction techniques he proposes. His simplifications describe the techniques of Hippocrates in a way they can be understood and used by athletes and nonphysicians in the Greek gymnasia. Perhaps his treatise is one of the earliest works of popularised medicine and surgery in the history of human civilisation.

  16. Ultrasonic Nondestructive Characterization of Adhesive Bonds

    NASA Technical Reports Server (NTRS)

    Qu, Jianmin

    1999-01-01

    Adhesives and adhesive joints are widely used in various industrial applications to reduce weight and costs, and to increase reliability. For example, advances in aerospace technology have been made possible, in part, through the use of lightweight materials and weight-saving structural designs. Joints, in particular, have been and continue to be areas in which weight can be trimmed from an airframe through the use of novel attachment techniques. In order to save weight over traditional riveted designs, to avoid the introduction of stress concentrations associated with rivet holes, and to take full advantage of advanced composite materials, engineers and designers have been specifying an ever-increasing number of adhesively bonded joints for use on airframes. Nondestructive characterization for quality control and remaining life prediction has been a key enabling technology for the effective use of adhesive joints. Conventional linear ultrasonic techniques generally can only detect flaws (delamination, cracks, voids, etc) in the joint assembly. However, more important to structural reliability is the bond strength. Although strength, in principle, cannot be measured nondestructively, a slight change in material nonlinearity may indicate the onset of failure. Furthermore, microstructural variations due to aging or under-curing may also cause changes in the third order elastic constants, which are related to the ultrasonic nonlinear parameter of the polymer adhesive. It is therefore reasonable to anticipate a correlation between changes in the ultrasonic nonlinear acoustic parameter and the remaining bond strength. It has been observed that higher harmonics of the fundamental frequency are generated when an ultrasonic wave passes through a nonlinear material. It seems that such nonlinearity can be effectively used to characterize bond strength. Several theories have been developed to model this nonlinear effect. Based on a microscopic description of the nonlinear interface binding force, a quantitative method was presented. Recently, a comparison between the experimental and simulated results based on a similar theoretical model was presented. A through-transmission setup for water immersion mode-converted shear waves was used to analyze the ultrasonic nonlinear parameter of an adhesive bond. In addition, ultrasonic guided waves have been used to analyze adhesive or diffusion bonded joints. In this paper, the ultrasonic nonlinear parameter is used to characterize the curing state of a polymer/aluminum adhesive joint. Ultrasonic through-transmission tests were conducted on samples cured under various conditions. The magnitude of the second order harmonic was measured and the corresponding ultrasonic nonlinear parameter was evaluated. A fairly good correlation between the curing condition and the nonlinear parameter is observed. The results show that the nonlinear parameter might be used as a good indicator of the cure state for adhesive joints.

  17. Wave Propagation in Discontinuous Media by the Scattering Matrix Method

    NASA Astrophysics Data System (ADS)

    Perino, A.; Orta, R.; Barla, G.

    2012-09-01

    Propagation of elastic waves in discontinuous media is studied in this paper by the scattering matrix method (SMM). An electromagnetic transmission line analogy is also used to set up the mathematical model. The SMM operates in the frequency domain and allows for all wave polarizations (P, SV and SH). Rock masses are examples of discontinuous media in which the discontinuities (fractures or joints) influence wave propagation. Both elastic and viscoelastic joints are considered and the latter are described by Kelvin-Voigt, Maxwell and Burgers models. Rock joints with Coulomb slip behavior are also analyzed, by applying the averaging principle of Caughy (J Appl Mech 27:640-643, 1960). The evaluation of the effects of periodic discontinuities in a homogeneous medium is presented by introducing the concept of Bloch waves. The dispersion curves of these waves are useful to explain the existence of frequency bands of strong attenuation, also in the case of lossless (perfectly elastic) structures. Simple expressions of transmission and reflection coefficients are obtained. Finally, the SMM results are compared with those computed via the distinct element method (DEM). The comparisons are performed on a medium with joints with Coulomb slip behavior and the agreement is satisfactory, although the SMM must be applied in conjunction with the equivalent linearization technique. Even if the DEM is much more general, the SMM in these simple cases is extremely faster and provides a higher physical insight.

  18. Effects of Design Variants in Lower-Limb Prostheses on Gait Synergy

    PubMed Central

    Pitkin, Mark R.

    2016-01-01

    A lower-limb prosthesis is the mechanical device with which an amputee’s residual limb interacts with the walking surface. The pressure and shear forces that affect the residuum due to prosthesis use are the sources of pain, residual-limb skin problems and gait deviations. Direct approaches to reducing these problems include improving fit, alignment technique and socket design as well as increasing cushioning with socket liners. A summary of typical malalignments and their consequences is presented. The malalignments are considered sources of excessive moments applied to the residuum, which simplifies the analysis of a patient’s gait. A better design of prosthetic joints could improve prosthetic gait. This article addresses the key mechanical parameter of prosthetic joints, namely the dependence “moment of resistance/angle of deflection.” A mathematical model has been developed that links stresses on the residuum in transtibial amputees with the moment of resistance in the prosthetic ankle at the critical gait phases. Analysis of the model yields a substantial decrease in stresses on the residuum during the most demanding, load-bearing phase of stance if the moment of resistance in the ankle is similar to that seen in the biological ankle joint. Gait study shows use of the experimental rolling-joint prosthetic foot more closely simulates normal gait synergy than the SACH foot. PMID:27087763

  19. Application of computer graphics in the design of custom orthopedic implants.

    PubMed

    Bechtold, J E

    1986-10-01

    Implementation of newly developed computer modelling techniques and computer graphics displays and software have greatly aided the orthopedic design engineer and physician in creating a custom implant with good anatomic conformity in a short turnaround time. Further advances in computerized design and manufacturing will continue to simplify the development of custom prostheses and enlarge their niche in the joint replacement market.

  20. Neuromuscular properties of different spastic human joints vary systematically.

    PubMed

    Mirbagheri, M M; Settle, K

    2010-01-01

    We quantified the mechanical abnormalities of the spastic wrist in chronic stroke survivors, and determined whether these findings were representative of those recorded at the elbow and ankle joints. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joints at different joint angles over the range of motion. Age-matched healthy subjects were used as control.

  1. An improved simulation based biomechanical model to estimate static muscle loadings

    NASA Technical Reports Server (NTRS)

    Rajulu, Sudhakar L.; Marras, William S.; Woolford, Barbara

    1991-01-01

    The objectives of this study are to show that the characteristics of an intact muscle are different from those of an isolated muscle and to describe a simulation based model. This model, unlike the optimization based models, accounts for the redundancy in the musculoskeletal system in predicting the amount of forces generated within a muscle. The results of this study show that the loading of the primary muscle is increased by the presence of other muscle activities. Hence, the previous models based on optimization techniques may underestimate the severity of the muscle and joint loadings which occur during manual material handling tasks.

  2. Predicting tibiotalar and subtalar joint angles from skin-marker data with dual-fluoroscopy as a reference standard.

    PubMed

    Nichols, Jennifer A; Roach, Koren E; Fiorentino, Niccolo M; Anderson, Andrew E

    2016-09-01

    Evidence suggests that the tibiotalar and subtalar joints provide near six degree-of-freedom (DOF) motion. Yet, kinematic models frequently assume one DOF at each of these joints. In this study, we quantified the accuracy of kinematic models to predict joint angles at the tibiotalar and subtalar joints from skin-marker data. Models included 1 or 3 DOF at each joint. Ten asymptomatic subjects, screened for deformities, performed 1.0m/s treadmill walking and a balanced, single-leg heel-rise. Tibiotalar and subtalar joint angles calculated by inverse kinematics for the 1 and 3 DOF models were compared to those measured directly in vivo using dual-fluoroscopy. Results demonstrated that, for each activity, the average error in tibiotalar joint angles predicted by the 1 DOF model were significantly smaller than those predicted by the 3 DOF model for inversion/eversion and internal/external rotation. In contrast, neither model consistently demonstrated smaller errors when predicting subtalar joint angles. Additionally, neither model could accurately predict discrete angles for the tibiotalar and subtalar joints on a per-subject basis. Differences between model predictions and dual-fluoroscopy measurements were highly variable across subjects, with joint angle errors in at least one rotation direction surpassing 10° for 9 out of 10 subjects. Our results suggest that both the 1 and 3 DOF models can predict trends in tibiotalar joint angles on a limited basis. However, as currently implemented, neither model can predict discrete tibiotalar or subtalar joint angles for individual subjects. Inclusion of subject-specific attributes may improve the accuracy of these models. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Measurement of damping of graphite epoxy composite materials and structural joints

    NASA Technical Reports Server (NTRS)

    Crocker, Malcolm J.; Rao, Mohan D.; Raju, P. K.; Yan, Xinche

    1989-01-01

    The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.

  4. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint

    PubMed Central

    Zhang, Xiangming

    2011-01-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint. PMID:21061141

  5. Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint.

    PubMed

    Zhang, Xiangming; Gan, Rong Z

    2011-10-01

    The incudostapedial (IS) joint between the incus and stapes is a synovial joint consisting of joint capsule, cartilage, and synovial fluid. The mechanical properties of the IS joint directly affect the middle ear transfer function for sound transmission. However, due to the complexity and small size of the joint, the mechanical properties of the IS joint have not been reported in the literature. In this paper, we report our current study on mechanical properties of human IS joint using both experimental measurement and finite element (FE) modeling analysis. Eight IS joint samples with the incus and stapes attached were harvested from human cadaver temporal bones. Tension, compression, stress relaxation and failure tests were performed on those samples in a micro-material testing system. An analytical approach with the hyperelastic Ogden model and a 3D FE model of the IS joint including the cartilage, joint capsule, and synovial fluid were employed to derive mechanical parameters of the IS joint. The comparison of measurements and modeling results reveals the relationship between the mechanical properties and structure of the IS joint.

  6. Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis.

    PubMed

    Wu, Tao; Ren, Xuejiao; Cui, Yunwei; Cheng, Xiaodong; Peng, Shuo; Hou, Zhiyong; Han, Yongtai

    2018-06-19

    To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.

  7. In vivo facet joint loading of the canine lumbar spine.

    PubMed

    Buttermann, G R; Schendel, M J; Kahmann, R D; Lewis, J L; Bradford, D S

    1992-01-01

    This study describes a technique to measure in vivo loads and the resultant load-contact locations in the facet joint of the canine lumbar spine. The technique is a modification of a previously described in vitro method that used calibrated surface strains of the lateral aspect of the right L3 cranial articular process. In the present study, strains were measured during various in vivo static and dynamic activities 3 days after strain gage implantation. The in vivo recording technique and its errors, which depend on the location of the applied facet loads, is described. The results of applying the technique to five dogs gave the following results. Relative resultant contact load locations on the facet tended to be in the central and caudal portion of the facet in extension activities, central and cranial in standing, and cranial and ventral in flexion or right-turning activities. Right-turning contact locations were ventral and cranial to left-turning locations. Resultant load locations at peak loading during walking were in the central region of the facet, whereas resultant load locations at minimum loading during walking were relatively craniad. This resultant load-contact location during a walk gait cycle typically migrated in an arc with a displacement of 4 mm from minimum to maximum loading. Static tests resulted in a range of facet loads of 0 N in flexion and lying to 185 N for two-legged standing erect, and stand resulted in facet loads of 26 +/- 15 N (mean +/- standard deviation [SD]). Dynamic tests resulted in peak facet loads ranging from 55 N while walking erect to 170 N for climbing up stairs. Maximum walk facet loads were 107 +/- 27 N. The technique is applicable to in vivo studies of a canine facet joint osteoarthritis model and may be useful for establishing an understanding of the biomechanics of low-back pain.

  8. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    NASA Astrophysics Data System (ADS)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.

  9. The Use of Biofeedback to Augment the Acquisition of Skills in Performing Joint Mobilization Techniques among Physical Therapy Students

    ERIC Educational Resources Information Center

    Timmerberg, Jean Fitzpatrick

    2011-01-01

    Despite the frequent use of joint mobilizations and the available evidence of its effectiveness as a treatment for various musculoskeletal disorders, it is a technique that has been shown to have great variability within and between raters. This variability is believed to occur because of differences between therapists' ability to perceive…

  10. Integrated Data Analysis for Fusion: A Bayesian Tutorial for Fusion Diagnosticians

    NASA Astrophysics Data System (ADS)

    Dinklage, Andreas; Dreier, Heiko; Fischer, Rainer; Gori, Silvio; Preuss, Roland; Toussaint, Udo von

    2008-03-01

    Integrated Data Analysis (IDA) offers a unified way of combining information relevant to fusion experiments. Thereby, IDA meets with typical issues arising in fusion data analysis. In IDA, all information is consistently formulated as probability density functions quantifying uncertainties in the analysis within the Bayesian probability theory. For a single diagnostic, IDA allows the identification of faulty measurements and improvements in the setup. For a set of diagnostics, IDA gives joint error distributions allowing the comparison and integration of different diagnostics results. Validation of physics models can be performed by model comparison techniques. Typical data analysis applications benefit from IDA capabilities of nonlinear error propagation, the inclusion of systematic effects and the comparison of different physics models. Applications range from outlier detection, background discrimination, model assessment and design of diagnostics. In order to cope with next step fusion device requirements, appropriate techniques are explored for fast analysis applications.

  11. Recent advances in computational mechanics of the human knee joint.

    PubMed

    Kazemi, M; Dabiri, Y; Li, L P

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling.

  12. Recent Advances in Computational Mechanics of the Human Knee Joint

    PubMed Central

    Kazemi, M.; Dabiri, Y.; Li, L. P.

    2013-01-01

    Computational mechanics has been advanced in every area of orthopedic biomechanics. The objective of this paper is to provide a general review of the computational models used in the analysis of the mechanical function of the knee joint in different loading and pathological conditions. Major review articles published in related areas are summarized first. The constitutive models for soft tissues of the knee are briefly discussed to facilitate understanding the joint modeling. A detailed review of the tibiofemoral joint models is presented thereafter. The geometry reconstruction procedures as well as some critical issues in finite element modeling are also discussed. Computational modeling can be a reliable and effective method for the study of mechanical behavior of the knee joint, if the model is constructed correctly. Single-phase material models have been used to predict the instantaneous load response for the healthy knees and repaired joints, such as total and partial meniscectomies, ACL and PCL reconstructions, and joint replacements. Recently, poromechanical models accounting for fluid pressurization in soft tissues have been proposed to study the viscoelastic response of the healthy and impaired knee joints. While the constitutive modeling has been considerably advanced at the tissue level, many challenges still exist in applying a good material model to three-dimensional joint simulations. A complete model validation at the joint level seems impossible presently, because only simple data can be obtained experimentally. Therefore, model validation may be concentrated on the constitutive laws using multiple mechanical tests of the tissues. Extensive model verifications at the joint level are still crucial for the accuracy of the modeling. PMID:23509602

  13. Design/analysis of the JWST ISIM bonded joints for survivability at cryogenic temperatures

    NASA Astrophysics Data System (ADS)

    Bartoszyk, Andrew; Johnston, John; Kaprielian, Charles; Kuhn, Jonathan; Kunt, Cengiz; Rodini, Benjamin; Young, Daniel

    2005-08-01

    A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite adhesively bonded joints at the cryogenic temperature of 30K (-405°F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to hybrid composite tubes (75mm square) made with M55J/954-6 and T300/954-6 prepregs. Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently, the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

  14. Flight test experience with high-alpha control system techniques on the F-14 airplane

    NASA Technical Reports Server (NTRS)

    Gera, J.; Wilson, R. J.; Enevoldson, E. K.; Nguyen, L. T.

    1981-01-01

    Improved handling qualities of fighter aircraft at high angles of attack can be provided by various stability and control augmentation techniques. NASA and the U.S. Navy are conducting a joint flight demonstration of these techniques on an F-14 airplane. This paper reports on the flight test experience with a newly designed lateral-directional control system which suppresses such high angle of attack handling qualities problems as roll reversal, wing rock, and directional divergence while simultaneously improving departure/spin resistance. The technique of integrating a piloted simulation into the flight program was used extensively in this program. This technique had not been applied previously to high angle of attack testing and required the development of a valid model to simulate the test airplane at extremely high angles of attack.

  15. Silver plating technique seals leaks in thin wall tubing joints

    NASA Technical Reports Server (NTRS)

    Blenderman, W. H.

    1966-01-01

    Leaks in thin wall tubing joints are sealed by cleaning and silver plating the hot gas side of the joint in the leakage area. The pressure differential across the silver during hydrostatic test and subsequent use forces the ductile silver into the leak area and seals it.

  16. Label-free characterization of articular cartilage in osteoarthritis model mice by Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Oshima, Yusuke; Akehi, Mayu; Kiyomatsu, Hiroshi; Miura, Hiromasa

    2017-02-01

    Osteoarthritis (OA) is very common joint disease in the aging population. Main symptom of OA is accompanied by degenerative changes of articular cartilage. Cartilage contains mostly type II collagen and proteoglycans, so it is difficult to access the quality and morphology of cartilage tissue in situ by conventional diagnostic tools (X-ray, MRI and echography) directly or indirectly. Raman spectroscopy is a label-free technique which enables to analyze molecular composition in degenerative cartilage. In this study, we generated an animal OA model surgically induced by knee joint instability, and the femurs were harvested at two weeks after the surgery. We performed Raman spectroscopic analysis for the articular cartilage of distal femurs in OA side and unaffected side in each mouse. In the result, there is no gross findings in the surface of the articular cartilage in OA. On the other hand, Raman spectral data of the articular cartilage showed drastic changes in comparison between OA and control side. The major finding of this study is that the relative intensity of phosphate band (960 cm-1) increases in the degenerative cartilage. This may be the result of exposure of subchondral bone due to thinning of the cartilage layer. In conclusion, Raman spectroscopic technique is sufficient to characterize articular cartilage in OA as a pilot study for Raman application in cartilage degeneration and regeneration using animal models and human subjects.

  17. Extracting joint weak values with local, single-particle measurements.

    PubMed

    Resch, K J; Steinberg, A M

    2004-04-02

    Weak measurement is a new technique which allows one to describe the evolution of postselected quantum systems. It appears to be useful for resolving a variety of thorny quantum paradoxes, particularly when used to study properties of pairs of particles. Unfortunately, such nonlocal or joint observables often prove difficult to measure directly in practice (for instance, in optics-a common testing ground for this technique-strong photon-photon interactions would be needed to implement an appropriate von Neumann interaction). Here we derive a general, experimentally feasible, method for extracting these joint weak values from correlations between single-particle observables.

  18. Evaluation of an Image-Based Tool to Examine the Effect of Fracture Alignment and Joint Congruency on Outcomes after Wrist Fracture.

    PubMed

    Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C

    2015-01-01

    Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.

  19. Biomechanical Comparison of an Intramedullary and Extramedullary Free-Tissue Graft Reconstruction of the Acromioclavicular Joint Complex

    PubMed Central

    Garg, Rishi; Javidan, Pooya; Lee, Thay Q.

    2013-01-01

    Background Several different surgical techniques have been described to address the coracoclavicular (CC) ligaments in acromioclavicular (AC) joint injuries. However, very few techniques focus on reconstructing the AC ligaments, despite its importance in providing stability. The purpose of our study was to compare the biomechanical properties of two free-tissue graft techniques that reconstruct both the AC and CC ligaments in cadaveric shoulders, one with an extramedullary AC reconstruction and the other with an intramedullary AC reconstruction. We hypothesized intramedullary AC reconstruction will provide greater anteroposterior translational stability and improved load to failure characteristics than an extramedullary technique. Methods Six matched cadaveric shoulders underwent translational testing at 10 N and 15 N in the anteroposterior and superoinferior directions, under AC joint compression loads of 10 N, 20 N, and 30 N. After the AC and CC ligaments were transected, one of the specimens was randomly assigned the intramedullary free-tissue graft reconstruction while its matched pair received the extramedullary graft reconstruction. Both reconstructed specimens then underwent repeat translational testing, followed by load to failure testing, via superior clavicle distraction, at a rate of 50 mm/min. Results Intramedullary reconstruction provided significantly greater translational stability in the anteroposterior direction than the extramedullary technique for four of six loading conditions (p < 0.05). There were no significant differences in translational stability in the superoinferior direction for any loading condition. The intramedullary reconstructed specimens demonstrated improved load to failure characteristics with the intramedullary reconstruction having a lower deformation at yield and a higher ultimate load than the extramedullary reconstruction (p < 0.05). Conclusions Intramedullary reconstruction of the AC joint provides greater stability in the anteroposterior direction and improved load to failure characteristics than an extramedullary technique. Reconstruction of the injured AC joint with an intramedullary free tissue graft may provide greater strength and stability than other currently used techniques, allowing patients to have improved clinical outcomes. PMID:24340150

  20. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    NASA Astrophysics Data System (ADS)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  1. Modified signed-digit trinary addition using synthetic wavelet filter

    NASA Astrophysics Data System (ADS)

    Iftekharuddin, K. M.; Razzaque, M. A.

    2000-09-01

    The modified signed-digit (MSD) number system has been a topic of interest as it allows for parallel carry-free addition of two numbers for digital optical computing. In this paper, harmonic wavelet joint transform (HWJT)-based correlation technique is introduced for optical implementation of MSD trinary adder implementation. The realization of the carry-propagation-free addition of MSD trinary numerals is demonstrated using synthetic HWJT correlator model. It is also shown that the proposed synthetic wavelet filter-based correlator shows high performance in logic processing. Simulation results are presented to validate the performance of the proposed technique.

  2. Technique of Dynamic Flexor Digitorum Superficialis Transfer to Lateral Bands for Proximal Interphalangeal Joint Deformity Correction in Severe Dupuytren Disease.

    PubMed

    Schreck, Michael J; Holbrook, Hayden S; Koman, L Andrew

    2018-02-01

    Pseudo-boutonniere deformity is an uncommon complication from long-standing proximal interphalangeal (PIP) joint contracture in Dupuytren disease. Prolonged flexion contracture of the PIP joint can lead to central slip attenuation and resultant imbalances in the extensor mechanism. We present a technique of flexor digitorum superficialis (FDS) tendon transfer to the lateral bands to correct pseudo-boutonniere deformity at the time of palmar fasciectomy for the treatment of Dupuytren disease. The FDS tendon is transferred from volar to dorsal through the lumbrical canal and sutured into the dorsally mobilized lateral bands. This technique presents an approach to the repair of pseudo-boutonniere deformity in Dupuytren disease. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Pseudo and conditional score approach to joint analysis of current count and current status data.

    PubMed

    Wen, Chi-Chung; Chen, Yi-Hau

    2018-04-17

    We develop a joint analysis approach for recurrent and nonrecurrent event processes subject to case I interval censorship, which are also known in literature as current count and current status data, respectively. We use a shared frailty to link the recurrent and nonrecurrent event processes, while leaving the distribution of the frailty fully unspecified. Conditional on the frailty, the recurrent event is assumed to follow a nonhomogeneous Poisson process, and the mean function of the recurrent event and the survival function of the nonrecurrent event are assumed to follow some general form of semiparametric transformation models. Estimation of the models is based on the pseudo-likelihood and the conditional score techniques. The resulting estimators for the regression parameters and the unspecified baseline functions are shown to be consistent with rates of square and cubic roots of the sample size, respectively. Asymptotic normality with closed-form asymptotic variance is derived for the estimator of the regression parameters. We apply the proposed method to a fracture-osteoporosis survey data to identify risk factors jointly for fracture and osteoporosis in elders, while accounting for association between the two events within a subject. © 2018, The International Biometric Society.

  4. Unified anomaly suppression and boundary extraction in laser radar range imagery based on a joint curve-evolution and expectation-maximization algorithm.

    PubMed

    Feng, Haihua; Karl, William Clem; Castañon, David A

    2008-05-01

    In this paper, we develop a new unified approach for laser radar range anomaly suppression, range profiling, and segmentation. This approach combines an object-based hybrid scene model for representing the range distribution of the field and a statistical mixture model for the range data measurement noise. The image segmentation problem is formulated as a minimization problem which jointly estimates the target boundary together with the target region range variation and background range variation directly from the noisy and anomaly-filled range data. This formulation allows direct incorporation of prior information concerning the target boundary, target ranges, and background ranges into an optimal reconstruction process. Curve evolution techniques and a generalized expectation-maximization algorithm are jointly employed as an efficient solver for minimizing the objective energy, resulting in a coupled pair of object and intensity optimization tasks. The method directly and optimally extracts the target boundary, avoiding a suboptimal two-step process involving image smoothing followed by boundary extraction. Experiments are presented demonstrating that the proposed approach is robust to anomalous pixels (missing data) and capable of producing accurate estimation of the target boundary and range values from noisy data.

  5. Model-Based Estimation of Knee Stiffness

    PubMed Central

    Pfeifer, Serge; Vallery, Heike; Hardegger, Michael; Riener, Robert; Perreault, Eric J.

    2013-01-01

    During natural locomotion, the stiffness of the human knee is modulated continuously and subconsciously according to the demands of activity and terrain. Given modern actuator technology, powered transfemoral prostheses could theoretically provide a similar degree of sophistication and function. However, experimentally quantifying knee stiffness modulation during natural gait is challenging. Alternatively, joint stiffness could be estimated in a less disruptive manner using electromyography (EMG) combined with kinetic and kinematic measurements to estimate muscle force, together with models that relate muscle force to stiffness. Here we present the first step in that process, where we develop such an approach and evaluate it in isometric conditions, where experimental measurements are more feasible. Our EMG-guided modeling approach allows us to consider conditions with antagonistic muscle activation, a phenomenon commonly observed in physiological gait. Our validation shows that model-based estimates of knee joint stiffness coincide well with experimental data obtained using conventional perturbation techniques. We conclude that knee stiffness can be accurately estimated in isometric conditions without applying perturbations, which presents an important step towards our ultimate goal of quantifying knee stiffness during gait. PMID:22801482

  6. Seismicity and structure of Akutan and Makushin Volcanoes, Alaska, using joint body and surface wave tomography

    DOE PAGES

    Syracuse, E. M.; Maceira, M.; Zhang, H.; ...

    2015-02-18

    Joint inversions of seismic data recover models that simultaneously fit multiple constraints while playing upon the strengths of each data type. Here, we jointly invert 14 years of local earthquake body wave arrival times from the Alaska Volcano Observatory catalog and Rayleigh wave dispersion curves based upon ambient noise measurements for local V p, V s, and hypocentral locations at Akutan and Makushin Volcanoes using a new joint inversion algorithm.The velocity structure and relocated seismicity of both volcanoes are significantly more complex than many other volcanoes studied using similar techniques. Seismicity is distributed among several areas beneath or beyond themore » flanks of both volcanoes, illuminating a variety of volcanic and tectonic features. The velocity structures of the two volcanoes are exemplified by the presence of narrow high-V p features in the near surface, indicating likely current or remnant pathways of magma to the surface. A single broad low-V p region beneath each volcano is slightly offset from each summit and centered at approximately 7 km depth, indicating a potential magma chamber, where magma is stored over longer time periods. Differing recovery capabilities of the Vp and Vs datasets indicate that the results of these types of joint inversions must be interpreted carefully.« less

  7. Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.

    PubMed

    Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H

    2013-06-01

    One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.

  8. Generation, absorption, and transfer of mechanical energy during walking in children.

    PubMed

    Umberger, Brian R; Augsburger, Sam; Resig, JoAnne; Oeffinger, Donna; Shapiro, Robert; Tylkowski, Chester

    2013-05-01

    The purpose of this study was to characterize the manner in which net joint moments and non-muscular forces generate, absorb, and transfer mechanical energy during walking in able-bodied children. Standard gait data from seven healthy subjects between 6 and 17 years of age were combined with a dynamic model of the whole body to perform a power analysis based on induced acceleration techniques. These data were used to determine how each moment and force generates energy to, absorbs energy from, and transfers energy among the major body segments. The joint moments were found to induce transfers of mechanical energy between body segments that generally exceeded the magnitudes of energy generation and absorption. The amount of energy transferred by gravitational and velocity-dependent forces was considerably less than for the joint moments. The hip and ankle joint moments had relatively simple power patterns that tended to oppose each other, particularly over the stance phase. The knee joint moment had a more complex power pattern that appeared distinct from the hip and ankle moments. The general patterns of mechanical energy flow were similar to previous reports in adults. The approach described in this paper should provide a useful complement to standard clinical gait analysis procedures. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Laser Welding Dissimilar Reflective Alloys

    NASA Technical Reports Server (NTRS)

    Mccay, M. H.; Gopinathan, S.; Kahlen, F.; Speigel, L.

    1993-01-01

    This project, jointly sponsored by Rocketdyne and CSTAR, involves the development of laser joining of materials which have heretofore been impractical to bond. Of particular interest are joints between stainless steel and copper and also aluminum 6061 to aluminum 2219. CSTAR has a unique opportunity in this area since both the process and development and diagnostics are of interest to industry. Initial results using the pulse tailored laser welding technique developed in CLA for joining crack sensitive materials have proven promising for the aluminum joints based upon metallurgical and electronic microprobe analysis. A declaration of success requires additional mechanical testing. A CW technique has been applied to the stainless-copper joining with some preliminary success. These joints are of significant interest for aeronautics and rocket propulsion applications and the project is expected to continue.

  10. Robust solder joint attachment of coaxial cable leads to piezoelectric ceramic electrodes.

    PubMed

    Vianco, P T

    1993-01-01

    A technique was developed for the solder attachment of coaxial cable leads to silver-bearing thick-film electrodes on piezoelectric ceramics. Soldering the cable leads directly to the thick film caused bonds with low mechanical strength due to poor solder joint geometry. A barrier coating of 1.5 mum Cu/1.5 mum Ni/1.0 mum Sn deposited on the thick-film layer improved the strength of the solder joints by eliminating the adsorption of Ag from the thick film, which was responsible for the improper solder joint geometry. The procedure does not require special preparation of the electrode surface and is cost effective due to the use of nonprecious metal films and the batch processing capabilities of the electron beam deposition technique.

  11. Laser welding dissimilar reflective alloys

    NASA Astrophysics Data System (ADS)

    McCay, M. H.; Gopinathan, S.; Kahlen, F.; Speigel, L.

    1993-01-01

    This project, jointly sponsored by Rocketdyne and CSTAR, involves the development of laser joining of materials which have heretofore been impractical to bond. Of particular interest are joints between stainless steel and copper and also aluminum 6061 to aluminum 2219. CSTAR has a unique opportunity in this area since both the process and development and diagnostics are of interest to industry. Initial results using the pulse tailored laser welding technique developed in CLA for joining crack sensitive materials have proven promising for the aluminum joints based upon metallurgical and electronic microprobe analysis. A declaration of success requires additional mechanical testing. A CW technique has been applied to the stainless-copper joining with some preliminary success. These joints are of significant interest for aeronautics and rocket propulsion applications and the project is expected to continue.

  12. Recent advances and future directions in the management of knee osteoarthritis: Can biological joint reconstruction replace joint arthroplasty and when?

    PubMed Central

    Paschos, Nikolaos K

    2015-01-01

    In this article, a concise description of the recent advances in the field of osteoarthritis management is presented. The main focus is to highlight the most promising techniques that emerge in both biological joint replacement and artificial joint arthroplasty. A critical view of high quality evidence regarding outcome and safety profile of these techniques is presented. The potential role of kinematically aligned total knee replacement, navigation, and robotic-assisted surgery is outlined. A critical description of both primary and stem cell-based therapies, the cell homing theory, the use of biologic factors and recent advancements in tissue engineering and regenerative medicine is provided. Based on the current evidence, some thoughts on a realistic approach towards answering these questions are attempted. PMID:26495242

  13. [Inferior hemiarthroplasty of the temporo-mandibular joint with articulated condylar prosthesis type Stryker].

    PubMed

    Bucur, A; Dincă, O; Totan, C; Ghită, V

    2007-01-01

    The optimal reconstruction of the mandible and of the temporo-mandibular joint after mandibular hemi-resection with disarticulation is still controversial in literature. This paperwork presents our experience on four cases in the reconstruction of the mandible together with the inferior arthroplasty of the temporo-mandibular joint, after the resection of extended benign tumors of the mandible, based on fibular free vascularized grafts having attached a Stryker titanium condylar prosthesis reconstructing the inferior segment of the temporo-mandibular joint. Our results for the this technique were excellent, with a functional rehabilitation very close to normal. After reviewing the various techniques and their arguments in literature, with accent on the TMJ reconstruction, we consider this method to be optimal for the reconstruction of mandibular defects in patients with neoplastic conditions.

  14. Combating Terrorism: A Conceptual Framework for Targeting at the Operational Level

    DTIC Science & Technology

    2004-06-17

    for Joint Intelligence Preparation of the Battlespace. The key process is the JIPB which is tried and tested , offering a very logical and clear...Intelligence Preparation of the Battlespace (JIPB) process, as published in Joint Publication 2-01.3, Joint Tactics, Techniques, and Procedures for Joint...Intelligence Preparation of the Battlespace, 24 May 2000, for its application to targeting terrorism at the operational level. The

  15. Pictorial review: MRI of the sternum and sternoclavicular joints.

    PubMed

    Aslam, M; Rajesh, A; Entwisle, J; Jeyapalan, K

    2002-07-01

    The sternum and sternoclavicular joints are difficult to evaluate with plain radiographs. The value of CT in assessing lesions of the sternum and sternoclavicular joints has been well documented, but the potential role of MRI has not been emphasized. We present the MRI techniques, normal appearances and a spectrum of abnormalities, and emphasize the role of MRI as a useful radiological investigation for the sternum and sternoclavicular joints.

  16. Derivation and test of elevated temperature thermal-stress-free fastener concept

    NASA Technical Reports Server (NTRS)

    Sawyer, J. W.; Blosser, M. L.; Mcwithey, R. R.

    1985-01-01

    Future aerospace vehicles must withstand high temperatures and be able to function over a wide temperature range. New composite materials are being developed for use in designing high-temperature lightweight structures. Due to the difference between coefficients of thermal expansion for the new composite materials and conventional high-temperature metallic fasteners, innovative joining techniques are needed to produce tight joints at all temperatures without excessive thermal stresses. A thermal-stress-free fastening technique is presented that can be used to provide structurally tight joints at all temperatures even when the fastener and joined materials have different coefficients of thermal expansion. The derivation of thermal-stress-free fasteners and joint shapes is presented for a wide variety of fastener materials and materials being joined together. Approximations to the thermal-stress-free shapes that result in joints with low-thermal-stresses and that simplify the fastener/joint shape are discussed. The low-thermal-stress fastener concept is verified by thermal and shear tests in joints using oxide-dispersion-strengthened alloy fasteners in carbon-carbon material. The test results show no evidence of thermal stress damage for temperatures up to 2000 F and the resulting joints carried shear loads at room temperature typical of those for conventional joints.

  17. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various joint configurations, including double cantilever beam and single lap joints.

  18. The coupling effects of kinematics and flexibility on the Lagrangian dynamic formulation of open chain deformable links

    NASA Technical Reports Server (NTRS)

    Changizi, Koorosh

    1989-01-01

    A nonlinear Lagrangian formulation for the spatial kinematic and dynamic analysis of open chain deformable links consisting of cylindrical joints that connect pairs of flexible links is developed. The special cases of revolute or prismatic joint can also be obtained from the kinematic equations. The kinematic equations are described using a 4x4 matrix method. The configuration of each deformable link in the open loop kinematic chain is identified using a coupled set of relative joint variables, constant geometric parameters, and elastic coordinates. The elastic coordinates define the link deformation with respect to a selected joint coordinate system that is consistent with the kinematic constraints on the boundary of the deformable link. These coordinates can be introduced using approximation techniques such as Rayleigh-Ritz method, finite element technique or any other desired approach. The large relative motion between two neighboring links are defined by a set of joint coordinates which describes the large relative translational and rotational motion between two neighboring joint coordinate systems. The origin of these coordinate systems are rigidly attached to the neighboring links at the joint definition points along the axis of motion.

  19. High Resolution Velocity Structure in Eastern Turkey

    NASA Astrophysics Data System (ADS)

    Pasyanos, M. E.; Gok, R.; Zor, E.; Walter, W. R.

    2004-12-01

    We investigate the crust and upper mantle structure of eastern Turkey where the Anatolian, Arabian and Eurasian Plates meet, forming a complex tectonic regime. The Bitlis suture is a continental collision zone between the Anatolian plateau and the Arabian plate. Broadband data available through the Eastern Turkey Seismic Experiment (ETSE) provide a unique opportunity for studying the high resolution velocity structure of the region. Zor et al. (2003) found an average 46 km thick crust in the Anatolian plateau using a six-layered grid search inversion of the ETSE receiver functions. Receiver functions are sensitive to the velocity contrast of interfaces and the relative travel time of converted and reverberated waves between those interfaces. The interpretation of receiver functions alone, however, may result in an apparent depth-velocity trade-off [Ammon et al., 1990]. In order to improve upon this velocity model, we have combined the receiver functions with surface wave data using the joint inversion method of Julia et al. (2000). In this technique, the two sets of observations are combined into a single algebraic equation and each data set is weighted by an estimate of the uncertainty in the observations. The receiver functions are calculated using an iterative time-domain deconvolution technique. We also consider azimuthal changes in the receiver functions and have stacked them into different groups accordingly. We are improving our surface wave model by making Love and Rayleigh dispersion measurements at the ETSE stations and incorporating them into a regional group velocity model for periods between 10 and 100 seconds. Preliminary results indicate a strong trend in the long period group velocities toward the northeast, indicating slow upper mantle velocities in the area consistent with Pn, Sn and receiver function results. Starting models used for the joint inversions include both a 1-D model from a 12-ton dam shot recorded by ETSE [Gurbuz et al., 2004] and the models from the original receiver function inversions. We observe that the joint inversion results are independent of the starting model and converge to the same final model, with some differences compared to the original profiles. While we don't observe significant changes in the first order discontinuities of the model, such as Moho depth, we are better able to resolve features in the crust.

  20. Characterisation of PDO olive oil Chianti Classico by non-selective (UV-visible, NIR and MIR spectroscopy) and selective (fatty acid composition) analytical techniques.

    PubMed

    Casale, M; Oliveri, P; Casolino, C; Sinelli, N; Zunin, P; Armanino, C; Forina, M; Lanteri, S

    2012-01-27

    An authentication study of the Italian PDO (protected designation of origin) extra virgin olive oil Chianti Classico was performed; UV-visible (UV-vis), Near-Infrared (NIR) and Mid-Infrared (MIR) spectroscopies were applied to a set of samples representative of the whole Chianti Classico production area. The non-selective signals (fingerprints) provided by the three spectroscopic techniques were utilised both individually and jointly, after fusion of the respective profile vectors, in order to build a model for the Chianti Classico PDO olive oil. Moreover, these results were compared with those obtained by the gas chromatographic determination of the fatty acids composition. In order to characterise the olive oils produced in the Chianti Classico PDO area, UNEQ (unequal class models) and SIMCA (soft independent modelling of class analogy) were employed both on the MIR, NIR and UV-vis spectra, individually and jointly, and on the fatty acid composition. Finally, PLS (partial least square) regression was applied on the UV-vis, NIR and MIR spectra, in order to predict the content of oleic and linoleic acids in the extra virgin olive oils. UNEQ, SIMCA and PLS were performed after selection of the relevant predictors, in order to increase the efficiency of both classification and regression models. The non-selective information obtained from UV-vis, NIR and MIR spectroscopy allowed to build reliable models for checking the authenticity of the Italian PDO extra virgin olive oil Chianti Classico. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Examining Moderation Analyses in Propensity Score Methods: Application to Depression and Substance Use

    PubMed Central

    Green, Kerry M.; Stuart, Elizabeth A.

    2014-01-01

    Objective This study provides guidance on how propensity score methods can be combined with moderation analyses (i.e., effect modification) to examine subgroup differences in potential causal effects in non-experimental studies. As a motivating example, we focus on how depression may affect subsequent substance use differently for men and women. Method Using data from a longitudinal community cohort study (N=952) of urban African Americans with assessments in childhood, adolescence, young adulthood and midlife, we estimate the influence of depression by young adulthood on substance use outcomes in midlife, and whether that influence varies by gender. We illustrate and compare five different techniques for estimating subgroup effects using propensity score methods, including separate propensity score models and matching for men and women, a joint propensity score model for men and women with matching separately and together by gender, and a joint male/female propensity score model that includes theoretically important gender interactions with matching separately and together by gender. Results Analyses showed that estimating separate models for men and women yielded the best balance and, therefore, is a preferred technique when subgroup analyses are of interest, at least in this data. Results also showed substance use consequences of depression but no significant gender differences. Conclusions It is critical to prespecify subgroup effects before the estimation of propensity scores and to check balance within subgroups regardless of the type of propensity score model used. Results also suggest that depression may affect multiple substance use outcomes in midlife for both men and women relatively equally. PMID:24731233

  2. Finite element models of the human shoulder complex: a review of their clinical implications and modelling techniques.

    PubMed

    Zheng, Manxu; Zou, Zhenmin; Bartolo, Paulo Jorge Da Silva; Peach, Chris; Ren, Lei

    2017-02-01

    The human shoulder is a complicated musculoskeletal structure and is a perfect compromise between mobility and stability. The objective of this paper is to provide a thorough review of previous finite element (FE) studies in biomechanics of the human shoulder complex. Those FE studies to investigate shoulder biomechanics have been reviewed according to the physiological and clinical problems addressed: glenohumeral joint stability, rotator cuff tears, joint capsular and labral defects and shoulder arthroplasty. The major findings, limitations, potential clinical applications and modelling techniques of those FE studies are critically discussed. The main challenges faced in order to accurately represent the realistic physiological functions of the shoulder mechanism in FE simulations involve (1) subject-specific representation of the anisotropic nonhomogeneous material properties of the shoulder tissues in both healthy and pathological conditions; (2) definition of boundary and loading conditions based on individualised physiological data; (3) more comprehensive modelling describing the whole shoulder complex including appropriate three-dimensional (3D) representation of all major shoulder hard tissues and soft tissues and their delicate interactions; (4) rigorous in vivo experimental validation of FE simulation results. Fully validated shoulder FE models would greatly enhance our understanding of the aetiology of shoulder disorders, and hence facilitate the development of more efficient clinical diagnoses, non-surgical and surgical treatments, as well as shoulder orthotics and prosthetics. © 2016 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd. © 2016 The Authors. International Journal for Numerical Methods in Biomedical Engineering published by John Wiley & Sons Ltd.

  3. Assessment of medial coronoid disease in 180 canine lame elbow joints: a sensitivity and specificity comparison of radiographic, computed tomographic and arthroscopic findings.

    PubMed

    Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I

    2015-09-25

    Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

  4. Application of three-dimensional rendering in joint-related ganglion cysts.

    PubMed

    Spinner, Robert J; Edwards, Phillip K; Amrami, Kimberly K

    2006-05-01

    The origin of para-articular cysts is poorly understood and controversial. The relatively common, simple (extraneural) cysts are presumed to be derived from joints, although joint connections are not always established. Rarer complex cysts are thought by many to form de novo within nerves (intraneural ganglion cysts) or within vessels (adventitial cysts) (degenerative theory). We believe that these simple and complex ganglion cysts are joint-related (articular theory). Joint connections are often not readily appreciated with routine imaging or at surgery. Not identifying and/or treating joint connections frequently leads to cyst recurrence. More sophisticated imaging may enhance visualization of these joint connections. We created a 3D rendering technique to assess potential joint connections of simple and complex cysts localized to the knee and superior tibiofibular joints in patients with fibular (peroneal) neuropathy. Two- and three-dimensional data sets from MRI examinations were segmented semiautomatically by signal intensity with further refinement based on interaction with the user to identify specific anatomic structures, such as small nerves and vessels on serial images. The bone, cysts, nerves, and vessels were each assigned different color representations, and 3D renderings were created in ANALYZE using the data sets closest to isotropic (voxel with equal length in all dimensions) resolution as the primary background rendering. We selected four cases to illustrate the spectrum of pathology. In all of these cases, we demonstrated joint connections and correlated imaging and operative findings. Surgery addressing the cyst and the joint connection resulted in excellent outcomes; postoperative MRIs done more than 6 months later confirmed that there was no recurrence. In addition to highlighting the important relationship of these cysts to neighboring anatomic structures, this 3D technique allows visualization of "occult" connections not readily appreciated with standard MR imaging. We believe that these joint-related cysts have a common pathogenesis; they dissect through a capsular rent and follow the path of least resistance; they may form simple cysts by dissecting out into the soft tissue, or more complex cysts by dissecting within the epineurium of nerves or adventitia of vessels (along an articular branch), or various combinations of all of these types of cysts. Understanding the pathogenesis for cyst formation will improve surgical management and outcomes. We have adapted this 3D technique to enhance the visualization of cysts occurring at other joints.

  5. An anatomically based protocol for the description of foot segment kinematics during gait.

    PubMed

    Leardini, A; Benedetti, M G; Catani, F; Simoncini, L; Giannini, S

    1999-10-01

    To design a technique for the in vivo description of ankle and other foot joint rotations to be applied in routine functional evaluation using non-invasive stereophotogrammetry. Position and orientation of tibia/fibula, calcaneus, mid-foot, 1st metatarsal and hallux segments were tracked during the stance phase of walking in nine asymptomatic subjects. Rigid clusters of reflective markers were used for foot segment pose estimation. Anatomical landmark calibration was applied for the reconstruction of anatomical landmarks. Previous studies have analysed only a limited number of joints or have proposed invasive techniques. Anatomical landmark trajectories were reconstructed in the laboratory frame using data from the anatomical calibration procedure. Anatomical co-ordinate frames were defined using the obtained landmark trajectories. Joint co-ordinate systems were used to calculate corresponding joint rotations in all three anatomical planes. The patterns of the joint rotations were highly repeatable within subjects. Consistent patterns between subjects were also exhibited at most of the joints. The method proposed enables a detailed description of ankle and other foot joint rotations on an anatomical base. Joint rotations can therefore be expressed in the well-established terminology necessary for their clinical interpretation. Functional evaluation of patients affected by foot diseases has recently called for more detailed and non-invasive protocols for the description of foot joint rotations during gait. The proposed method can help clinicians to distinguish between normal and pathological pattern of foot joint rotations, and to quantitatively assess the restoration of normal function after treatment.

  6. Finite element model updating of riveted joints of simplified model aircraft structure

    NASA Astrophysics Data System (ADS)

    Yunus, M. A.; Rani, M. N. Abdul; Sani, M. S. M.; Shah, M. A. S. Aziz

    2018-04-01

    Thin metal sheets are widely used to fabricate a various type of aerospace structures because of its flexibility and easily to form into any type shapes of structure. The riveted joint has turn out to be one of the popular joint types in jointing the aerospace structures because they can be easily be disassembled, maintained and inspected. In this paper, thin metal sheet components are assembled together via riveted joints to form a simplified model of aerospace structure. However, to model the jointed structure that are attached together via the mechanical joints such as riveted joint are very difficult due to local effects. Understandably that the dynamic characteristic of the joined structure can be significantly affected by these joints due to local effects at the mating areas of the riveted joints such as surface contact, clamping force and slips. A few types of element connectors that available in MSC NATRAN/PATRAN have investigated in order to presented as the rivet joints. Thus, the results obtained in term of natural frequencies and mode shapes are then contrasted with experimental counterpart in order to investigate the acceptance level of accuracy between element connectors that are used in modelling the rivet joints of the riveted joints structure. The reconciliation method via finiteelement model updating is used to minimise the discrepancy of the initial finite element model of the riveted joined structure as close as experimental data and their results are discussed.

  7. Dynamic motion planning of 3D human locomotion using gradient-based optimization.

    PubMed

    Kim, Hyung Joo; Wang, Qian; Rahmatalla, Salam; Swan, Colby C; Arora, Jasbir S; Abdel-Malek, Karim; Assouline, Jose G

    2008-06-01

    Since humans can walk with an infinite variety of postures and limb movements, there is no unique solution to the modeling problem to predict human gait motions. Accordingly, we test herein the hypothesis that the redundancy of human walking mechanisms makes solving for human joint profiles and force time histories an indeterminate problem best solved by inverse dynamics and optimization methods. A new optimization-based human-modeling framework is thus described for predicting three-dimensional human gait motions on level and inclined planes. The basic unknowns in the framework are the joint motion time histories of a 25-degree-of-freedom human model and its six global degrees of freedom. The joint motion histories are calculated by minimizing an objective function such as deviation of the trunk from upright posture that relates to the human model's performance. A variety of important constraints are imposed on the optimization problem, including (1) satisfaction of dynamic equilibrium equations by requiring the model's zero moment point (ZMP) to lie within the instantaneous geometrical base of support, (2) foot collision avoidance, (3) limits on ground-foot friction, and (4) vanishing yawing moment. Analytical forms of objective and constraint functions are presented and discussed for the proposed human-modeling framework in which the resulting optimization problems are solved using gradient-based mathematical programming techniques. When the framework is applied to the modeling of bipedal locomotion on level and inclined planes, acyclic human walking motions that are smooth and realistic as opposed to less natural robotic motions are obtained. The aspects of the modeling framework requiring further investigation and refinement, as well as potential applications of the framework in biomechanics, are discussed.

  8. Open capsular and ligament reconstruction with semitendinosus hamstring autograft successfully controls superior and posterior translation for type V acromioclavicular joint dislocation.

    PubMed

    Garofalo, Raffaele; Ceccarelli, Enrico; Castagna, Alessandro; Calvisi, Vittorio; Flanagin, Brody; Conti, Marco; Krishnan, Sumant G

    2017-07-01

    Appropriate surgical management for type V complete acromioclavicular (AC) joint dislocation remains controversial. The purpose of this paper is to retrospectively report the clinical and radiographic outcomes of an open surgical technique consisting for AC joint ligamentous and capsular reconstruction using autologous hamstring tendon grafts and semi-permanent sutures. Between January 2005 and December 2011, 32 consecutive patients with symptomatic type V complete AC joint dislocation underwent surgical treatment using the same technique. The median time from injury to surgery was 45 days (range 24-90). The average median postoperative clinical and radiographic follow-up time was 30 months (range 24-33). Clinical outcomes measures included the ASES score, the visual analog score (VAS), and subjective patient satisfaction score. Minimum follow-up was 2 years. ASES score increased from a median of 38.2 ± 6.2 preoperative to 92.1 ± 4.7 postoperatively (p ≤ 0.05). The median VAS score improved from 62 mm (range 45-100 mm) preoperatively to 8 mm (range 0-20 mm) at final follow-up (p ≤ 0.05). No patient experienced pain or discomfort with either direct palpation of the AC joint or with cross-body adduction. Final radiographs demonstrated symmetric AC joint contour in 25/32 (78%) patients. Seven patients (22%) radiographically demonstrated superior translation of the distal clavicle relative to the superior margin of the acromion but less than 50% of the clavicular width. 30/32 patients (93%) were able to return to their pre-injury level of work and sports activities. This novel surgical technique using a free graft and braided suture for simultaneous coracoclavicular ligament and AC joint capsular reconstruction successfully controls superior and posterior translations after type V AC joint dislocation and minimizes the incidence of persistent postoperative AC joint subluxation. Retrospective case series, Level IV.

  9. Multivariate Bias Correction Procedures for Improving Water Quality Predictions from the SWAT Model

    NASA Astrophysics Data System (ADS)

    Arumugam, S.; Libera, D.

    2017-12-01

    Water quality observations are usually not available on a continuous basis for longer than 1-2 years at a time over a decadal period given the labor requirements making calibrating and validating mechanistic models difficult. Further, any physical model predictions inherently have bias (i.e., under/over estimation) and require post-simulation techniques to preserve the long-term mean monthly attributes. This study suggests a multivariate bias-correction technique and compares to a common technique in improving the performance of the SWAT model in predicting daily streamflow and TN loads across the southeast based on split-sample validation. The approach is a dimension reduction technique, canonical correlation analysis (CCA) that regresses the observed multivariate attributes with the SWAT model simulated values. The common approach is a regression based technique that uses an ordinary least squares regression to adjust model values. The observed cross-correlation between loadings and streamflow is better preserved when using canonical correlation while simultaneously reducing individual biases. Additionally, canonical correlation analysis does a better job in preserving the observed joint likelihood of observed streamflow and loadings. These procedures were applied to 3 watersheds chosen from the Water Quality Network in the Southeast Region; specifically, watersheds with sufficiently large drainage areas and number of observed data points. The performance of these two approaches are compared for the observed period and over a multi-decadal period using loading estimates from the USGS LOADEST model. Lastly, the CCA technique is applied in a forecasting sense by using 1-month ahead forecasts of P & T from ECHAM4.5 as forcings in the SWAT model. Skill in using the SWAT model for forecasting loadings and streamflow at the monthly and seasonal timescale is also discussed.

  10. Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty

    PubMed Central

    Moon, Young-Wan; Kim, Hyun-Jung; Ahn, Hyeong-Sik; Park, Chan-Deok; Lee, Dae-Hee

    2016-01-01

    Abstract Background: This meta-analysis was designed to compare the accuracy of soft tissue balancing and femoral component rotation as well as change in joint line positions, between the measured resection and gap balancing techniques in primary total knee arthroplasty. Methods: Studies were included in the meta-analysis if they compared soft tissue balancing and/or radiologic outcomes in patients who underwent total knee arthroplasty with the gap balancing and measured resection techniques. Comparisons included differences in flexion/extension, medial/lateral flexion, and medial/lateral extension gaps (LEGs), femoral component rotation, and change in joint line positions. Finally, 8 studies identified via electronic (MEDLINE, EMBASE, and the Cochrane Library) and manual searches were included. All 8 studies showed a low risk of selection bias and provided detailed demographic data. There was some inherent heterogeneity due to uncontrolled bias, because all included studies were observational comparison studies. Results: The pooled mean difference in gap differences between the gap balancing and measured resection techniques did not differ significantly (−0.09 mm, 95% confidence interval [CI]: −0.40 to +0.21 mm; P = 0.55), except that the medial/LEG difference was 0.58 mm greater for measured resection than gap balancing (95% CI: −1.01 to −0.15 mm; P = 0.008). Conversely, the pooled mean difference in femoral component external rotation (0.77°, 95% CI: 0.18° to 1.35°; P = 0.01) and joint line change (1.17 mm, 95% CI: 0.82 to 1.52 mm; P < 0.001) were significantly greater for the gap balancing than the measured resection technique. Conclusion: The gap balancing and measured resection techniques showed similar soft tissue balancing, except for medial/LEG difference. However, the femoral component was more externally rotated and the joint line was more elevated with gap balancing than measured resection. These differences were minimal (around 1 mm or 1°) and therefore may have little effect on the biomechanics of the knee joint. This suggests that the gap balancing and measured resection techniques are not mutually exclusive. PMID:27684862

  11. Validation of the Transient Structural Response of a Threaded Assembly: Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doebling, Scott W.; Hemez, Francois M.; Robertson, Amy N.

    2004-04-01

    This report explores the application of model validation techniques in structural dynamics. The problem of interest is the propagation of an explosive-driven mechanical shock through a complex threaded joint. The study serves the purpose of assessing whether validating a large-size computational model is feasible, which unit experiments are required, and where the main sources of uncertainty reside. The results documented here are preliminary, and the analyses are exploratory in nature. The results obtained to date reveal several deficiencies of the analysis, to be rectified in future work.

  12. Space - A unique environment for process modeling R&D

    NASA Technical Reports Server (NTRS)

    Overfelt, Tony

    1991-01-01

    Process modeling, the application of advanced computational techniques to simulate real processes as they occur in regular use, e.g., welding, casting and semiconductor crystal growth, is discussed. Using the low-gravity environment of space will accelerate the technical validation of the procedures and enable extremely accurate determinations of the many necessary thermophysical properties. Attention is given to NASA's centers for the commercial development of space; joint ventures of universities, industries, and goverment agencies to study the unique attributes of space that offer potential for applied R&D and eventual commercial exploitation.

  13. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    PubMed

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial Society of Bone & Joint Surgery.

  14. A study of the anatomy and injection techniques of the ovine stifle by positive contrast arthrography, computed tomography arthrography and gross anatomical dissection.

    PubMed

    Vandeweerd, Jean-Michel; Kirschvink, Nathalie; Muylkens, Benoit; Depiereux, Eric; Clegg, Peter; Herteman, Nicolas; Lamberts, Matthieu; Bonnet, Pierre; Nisolle, Jean-Francois

    2012-08-01

    Although ovine stifle models are commonly used to study osteoarthritis, meniscal pathology and cruciate ligament injuries and repair, there is little information about the anatomy of the joint or techniques for synovial injections. The objectives of this study were to improve anatomical knowledge of the synovial cavities of the ovine knee and to compare intra-articular injection techniques. Synovial cavities of 24 cadaver hind limbs from 12 adult sheep were investigated by intra-articular resin, positive-contrast arthrography, computed tomography (CT) arthrography and gross anatomical dissection. Communication between femoro-patellar, medial femoro-tibial and lateral femoro-tibial compartments occurred in all cases. The knee joint should be considered as one synovial structure with three communicating compartments. Several unreported features were observed, including a communication between the medial femoro-tibial and lateral femoro-tibial compartments and a latero-caudal recess of the lateral femoro-tibial compartment. No intermeniscal ligament was identified. CT was able to define many anatomical features of the stifle, including the anatomy of the tendinous synovial recess on the lateral aspect of the proximal tibia under the combined tendon of the peroneus tertius, extensor longus digitorum and extensor digiti III proprius. An approach for intra-articular injection into this recess (the subtendinous technique) was assessed and compared with the retropatellar and paraligamentous techniques. All three injection procedures were equally successful, but the subtendinous technique appeared to be most appropriate for synoviocentesis and for injections in therapeutic research protocols with less risk of damaging the articular cartilage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. In vivo kinematic study of the tarsal joints complex based on fluoroscopic 3D-2D registration technique.

    PubMed

    Chen Wang, M D; Geng, Xiang; Wang, Shaobai; Xin Ma, M D; Xu Wang, M D; Jiazhang Huang, M D; Chao Zhang, M D; Li Chen, M S; Yang, Junsheng; Wang, Kan

    2016-09-01

    The tarsal bones articulate with each other and demonstrate complicated kinematic characteristics. The in vivo motions of these tarsal joints during normal gait are still unclear. Seven healthy subjects were recruited and fourteen feet in total were tested in the current study. Three dimensional models of the tarsal bones were first created using CT scanning. Corresponding local 3D coordinate systems of each tarsal bone was subsequently established for 6DOF motion decompositions. The fluoroscopy system captured the lateral fluoroscopic images of the targeted tarsal region whilst the subject was walking. Seven key pose images during the stance phase were selected and 3D to 2D bone model registrations were performed on each image to determine joint positions. The 6DOF motions of each tarsal joint during gait were then obtained by connecting these positions together. The TNJ (talo-navicular joint) exhibited the largest ROMs (range of motion) on all rotational directions with 7.39±2.75°of dorsi/plantarflexion, 21.12±4.68°of inversion/eversion, and 16.11±4.44°of internal/external rotation. From heel strike to midstance, the TNJ, STJ (subtalar joint), and CCJ (calcaneao-cuboid joint) were associated with 5.97°, 5.04°, and 3.93°of dorsiflexion; 15.46°, 8.21°, and 5.82°of eversion; and 9.75°, 7.6°, and 4.99°of external rotation, respectively. Likewise, from midstance to heel off, the TNJ, STJ, and CCJ were associated with 6.39, 6.19°, and 4.47°of plantarflexion; 18.57°, 11.86°, and 6.32°of inversion and 13.95°, 9.66°, and 7.58°of internal rotation, respectively. In conclusion, among the tarsal joints, the TNJ exhibited the greatest rotational mobility. Synchronous and homodromous rotational motions were detected for TNJ, STJ, and CCJ during the stance phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Joint projections of sea level and storm surge using a flood index

    NASA Astrophysics Data System (ADS)

    Little, C. M.; Lin, N.; Horton, R. M.; Kopp, R. E.; Oppenheimer, M.

    2016-02-01

    Capturing the joint influence of sea level rise (SLR) and tropical cyclones (TCs) on future coastal flood risk poses significant challenges. To address these difficulties, Little et al. (2015) use a proxy of tropical cyclone activity and a probabilistic flood index that aggregates flood height and duration over a wide area (the US East and Gulf coasts). This technique illuminates the individual impacts of TCs and SLR and their correlation across different coupled climate models. By 2080-2099, changes in the flood index relative to 1986-2005 are substantial and positively skewed: a 10th-90th percentile range of 35-350x higher for a high-end business-as-usual emissions scenario (see figure). This aggregated flood index: 1) is a means to consistently combine TC-driven storm surges and SLR; 2) provides a more robust description of historical surge-climate relationships than is available at any one location; and 3) allows the incorporation of a larger climate model ensemble - which is critical to uncertainty characterization. It does not provide a local view of the complete spectrum of flood severity (i.e. return curves). However, alternate techniques that provide localized return curves (e.g. Lin et al., 2012) are computationally intensive, limiting the set of large-scale climate models that can be incorporated, and require several linked statistical and dynamical models, each with structural uncertainties that are difficult to quantify. Here, we present the results of Little et al. (2015) along with: 1) alternate formulations of the flood index; 2) strategies to localize the flood index; and 3) a comparison of flood index projections to those provided by model-based return curves. We look to this interdisciplinary audience for feedback on the advantages and disadvantages of each tool for coastal planning and decision-making. Lin, N., K. Emanuel, M. Oppenheimer, and E. Vanmarcke, 2012: Physically based assessment of hurricane surge threat under climate change. Nature Clim. Change, 2(6), 462-467. Little, C. M., R. M. Horton, R. E. Kopp, M. Oppenheimer, G. A. Vecchi, and G. Villarini, 2015: Joint projections of us east coast sea level and storm surge. Nature Clim. Change, advance online publication.

  17. Repair and tissue engineering techniques for articular cartilage

    PubMed Central

    Makris, Eleftherios A.; Gomoll, Andreas H.; Malizos, Konstantinos N.; Hu, Jerry C.; Athanasiou, Kyriacos A.

    2015-01-01

    Chondral and osteochondral lesions due to injury or other pathology commonly result in the development of osteoarthritis, eventually leading to progressive total joint destruction. Although current progress suggests that biologic agents can delay the advancement of deterioration, such drugs are incapable of promoting tissue restoration. The limited ability of articular cartilage to regenerate renders joint arthroplasty an unavoidable surgical intervention. This Review describes current, widely used clinical repair techniques for resurfacing articular cartilage defects; short-term and long-term clinical outcomes of these techniques are discussed. Also reviewed is a developmental pipeline of regenerative biological products that over the next decade could revolutionize joint care by functionally healing articular cartilage. These products include cell-based and cell-free materials such as autologous and allogeneic cell-based approaches and multipotent and pluripotent stem-cell-based techniques. Central to these efforts is the prominent role that tissue engineering has in translating biological technology into clinical products; therefore, concomitant regulatory processes are also discussed. PMID:25247412

  18. Kinematically redundant robot manipulators

    NASA Technical Reports Server (NTRS)

    Baillieul, J.; Hollerbach, J.; Brockett, R.; Martin, D.; Percy, R.; Thomas, R.

    1987-01-01

    Research on control, design and programming of kinematically redundant robot manipulators (KRRM) is discussed. These are devices in which there are more joint space degrees of freedom than are required to achieve every position and orientation of the end-effector necessary for a given task in a given workspace. The technological developments described here deal with: kinematic programming techniques for automatically generating joint-space trajectories to execute prescribed tasks; control of redundant manipulators to optimize dynamic criteria (e.g., applications of forces and moments at the end-effector that optimally distribute the loading of actuators); and design of KRRMs to optimize functionality in congested work environments or to achieve other goals unattainable with non-redundant manipulators. Kinematic programming techniques are discussed, which show that some pseudo-inverse techniques that have been proposed for redundant manipulator control fail to achieve the goals of avoiding kinematic singularities and also generating closed joint-space paths corresponding to close paths of the end effector in the workspace. The extended Jacobian is proposed as an alternative to pseudo-inverse techniques.

  19. Fluoroscopic Sacroiliac Joint Injection: Is Oblique Angulation Really Necessary?

    PubMed

    Khuba, Sandeep; Agarwal, Anil; Gautam, Sujeet; Kumar, Sanjay

    2016-01-01

    The conventional technique for sacroiliac (SI) joint injection involves aligning the anterior and posterior aspects of the SI joint under fluoroscopic guidance and then entering the SI joint in the most caudal aspect. We wish to highlight that there is no added advantage to aligning both the anterior and posterior joint lines of the SI joint as it is time consuming, associated with additional radiation exposure, and may make the entry into the posterior SI joint technically more difficult. Observational study. Pain Clinic, Department of Anesthesiology. With the patient lying prone on fluoroscopy table, SI joint injection is performed with a 22 G, 10 cm spinal needle in a true anteroposterior (AP) view, where anterior and posterior SI joint spaces are seen as separate entities, where the medial joint space represents the posterior SI joint and the lateral joint space represents the anterior SI joint. The distal 1 cm of the medial joint space is entered under AP view. If the SI joint is seen as a straight line rather than 2 joint spaces in the AP view then the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint, thus facilitating entry into this part of the joint which was confirmed by administering 0.3 to 0.5 mL of radiopaque contrast medium. Sixty SI joints of 58 patients were injected under an AP fluoroscopic view. Forty-two (70%) SI joints were seen as 2 separate medial and lateral joint spaces and were entered in distal 1 cm of the medial joint space. In 18 (30%) joints seen as a straight line rather than 2 separate spaces, the image intensifier of the fluoroscope was tilted cranially to elongate the image of the lower part of the posterior SI joint and then the SI joint was entered in its distal 1 cm. Confirmation of entry into the SI joint was confirmed by with 0.3 to 0.5 mL of radiopaque contrast medium. In 4 cases the joints did not show the correct radiopaque contrast spread (3/42 and 1/18) although the needle seemed to be in the joint space. Small sample size. Aligning the anterior and posterior aspects of SI joint for fluoroscopic guided SI joint injection is not necessary for the success of the block.Key words: Sacroiliac joint, injection, anteroposterior view, oblique angulation, fluoroscopic technique.

  20. Dubious space for Artelon joint resurfacing for basal thumb (trapeziometacarpal joint) osteoarthritis. A systematic review.

    PubMed

    Smeraglia, Francesco; Mariconda, Massimo; Balato, Giovanni; Di Donato, Sigismondo Luca; Criscuolo, Giovanni; Maffulli, Nicola

    2018-06-01

    Trapeziometacarpal arthritis is a common and disabling condition. There is no evidence in the literature of superiority of one surgical procedure over others. Several prosthetic implants have been introduced to preserve joint mobility. We searched the on Medline (PubMed), Web of Science and Scopus databases using the combined keywords 'artelon', 'thumb', 'carpometacarpal', 'trapeziometacarpal' and 'rhizoarthrosis'; 11 studies were identified. The use of Artelon implant is not recommended because of its high revision rate and worse outcomes compared to conventional techniques. Inert materials subjected to compressive and shearing forces could produce debris and subsequent inflammatory response. There is debate in the published scientific literature regarding the role of preoperative antibiotic profilaxis and post-surgery inflammatory response. Standard techniques such as trapeziectomy alone or combined with interposition or suspensionplasty offer effective treatment for thumb basal joint arthritis. Several prosthetic implants show promising results in terms of pain relief and functional request, but there is a need of long-term randomized controlled trials to demonstrate their equivalence, and eventually superiority, compared to standard techniques.

  1. On the use of the EMI for the health monitoring of bonded elements

    NASA Astrophysics Data System (ADS)

    Gulizzi, Vincenzo; Rizzo, Piervincenzo; Milazzo, Alberto

    2014-03-01

    The low weight, robustness and fatigue resistance of adhesive joints make them suitable for structural joints. A fully developed nondestructive evaluation technique however is needed to monitor and assess the quality of bonded joints. In the present paper the application of the electromechanical impedance (EMI) technique is proposed. In the EMI method a piezoelectric transducer (PZT) is attached to the structure of interest. The high sensitivity and low power consumption make the EMI method feasible for real time structural health monitoring. In this study we investigated the sensitivity of the electromechanical response of a PZT to the curing and the quality of the adhesive used for bonded joints. A PXI unit running under LabView and an auxiliary circuit were employed to measure the electric impedance of a PZT glued to an aluminum plate. The system aimed at monitoring the bond line between an aluminum strip and the plate. The conductive signature of the PZT was measured and analyzed during the curing. The experimental results show that the electromechanical impedance technique is sensitive to the curing time and variations are observed for adhesives of different quality.

  2. Optimization and Characterization of the Friction Stir Welded Sheets of AA 5754-H111: Monitoring of the Quality of Joints with Thermographic Techniques

    PubMed Central

    De Filippis, Luigi Alberto Ciro; Serio, Livia Maria; Galietti, Umberto

    2017-01-01

    Friction Stir Welding (FSW) is a solid-state welding process, based on frictional and stirring phenomena, that offers many advantages with respect to the traditional welding methods. However, several parameters can affect the quality of the produced joints. In this work, an experimental approach has been used for studying and optimizing the FSW process, applied on 5754-H111 aluminum plates. In particular, the thermal behavior of the material during the process has been investigated and two thermal indexes, the maximum temperature and the heating rate of the material, correlated to the frictional power input, were investigated for different process parameters (the travel and rotation tool speeds) configurations. Moreover, other techniques (micrographs, macrographs and destructive tensile tests) were carried out for supporting in a quantitative way the analysis of the quality of welded joints. The potential of thermographic technique has been demonstrated both for monitoring the FSW process and for predicting the quality of joints in terms of tensile strength. PMID:29019948

  3. How joint characteristics between a piezoelectric beam and the main structure affect the performance of an energy harvester

    NASA Astrophysics Data System (ADS)

    Jahani, K.; Rafiei, M. M.; Aghazadeh, P.

    2017-09-01

    In this paper, the influence of the joint region between a piezoelectric energy harvesting beam and the vibratory main structure is studied. The investigations are conducted in two separate sections, namely numerical and experimental studies. In numerical studies, the effects of nonlinear parameters on generated power are investigated while the joint characteristics the between vibrating base and a piezoelectric energy harvester are taken into consideration. A unimorph beam with a tip mass and a nonlinear piezoelectric layer that undergoes a large-amplitude deflection is considered as an energy harvester. By applying the Euler-Lagrange equation and Gauss’s law the mechanical and electrical equations of motion are obtained, respectively. The excitation frequency is assumed to be close to the first natural frequency. Thus, a unimodal response is considered to be like that of a system with a single degree of freedom (SDOF). The joint between the vibrating main structure and the cantilevered beam is then added to the SDOF model. The joint characteristics are simulated with a light mass, mj , linear spring stiffness, kj , and equivalent viscous damper, cj . In two scenarios, i.e. with a rigid joint and with a flexible one, a numerical approach is followed to investigate the effects of each nonlinear parameter of the harvester (stiffness, damping and piezoelectric coefficient) on the harvested power. In experimental studies, the influence of a bolted joining technique and a flexible adhesive bonding method on the harvested power is investigated. The results achieved experimentally confirm those obtained numerically, i.e. a stiffer joint leads to a greater power produced by the harvester. In other words, neglecting the joint characteristics will cause the performance (maximum output power and the range of excitation frequency) of the harvester to be overestimated in numerical simulations.

  4. An efficient parallel sampling technique for Multivariate Poisson-Lognormal model: Analysis with two crash count datasets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhan, Xianyuan; Aziz, H. M. Abdul; Ukkusuri, Satish V.

    Our study investigates the Multivariate Poisson-lognormal (MVPLN) model that jointly models crash frequency and severity accounting for correlations. The ordinary univariate count models analyze crashes of different severity level separately ignoring the correlations among severity levels. The MVPLN model is capable to incorporate the general correlation structure and takes account of the over dispersion in the data that leads to a superior data fitting. But, the traditional estimation approach for MVPLN model is computationally expensive, which often limits the use of MVPLN model in practice. In this work, a parallel sampling scheme is introduced to improve the original Markov Chainmore » Monte Carlo (MCMC) estimation approach of the MVPLN model, which significantly reduces the model estimation time. Two MVPLN models are developed using the pedestrian vehicle crash data collected in New York City from 2002 to 2006, and the highway-injury data from Washington State (5-year data from 1990 to 1994) The Deviance Information Criteria (DIC) is used to evaluate the model fitting. The estimation results show that the MVPLN models provide a superior fit over univariate Poisson-lognormal (PLN), univariate Poisson, and Negative Binomial models. Moreover, the correlations among the latent effects of different severity levels are found significant in both datasets that justifies the importance of jointly modeling crash frequency and severity accounting for correlations.« less

  5. An efficient parallel sampling technique for Multivariate Poisson-Lognormal model: Analysis with two crash count datasets

    DOE PAGES

    Zhan, Xianyuan; Aziz, H. M. Abdul; Ukkusuri, Satish V.

    2015-11-19

    Our study investigates the Multivariate Poisson-lognormal (MVPLN) model that jointly models crash frequency and severity accounting for correlations. The ordinary univariate count models analyze crashes of different severity level separately ignoring the correlations among severity levels. The MVPLN model is capable to incorporate the general correlation structure and takes account of the over dispersion in the data that leads to a superior data fitting. But, the traditional estimation approach for MVPLN model is computationally expensive, which often limits the use of MVPLN model in practice. In this work, a parallel sampling scheme is introduced to improve the original Markov Chainmore » Monte Carlo (MCMC) estimation approach of the MVPLN model, which significantly reduces the model estimation time. Two MVPLN models are developed using the pedestrian vehicle crash data collected in New York City from 2002 to 2006, and the highway-injury data from Washington State (5-year data from 1990 to 1994) The Deviance Information Criteria (DIC) is used to evaluate the model fitting. The estimation results show that the MVPLN models provide a superior fit over univariate Poisson-lognormal (PLN), univariate Poisson, and Negative Binomial models. Moreover, the correlations among the latent effects of different severity levels are found significant in both datasets that justifies the importance of jointly modeling crash frequency and severity accounting for correlations.« less

  6. Metacarpophalangeal joint arthroscopy: indications revisited.

    PubMed

    Choi, Alexander K Y; Chow, Esther C S; Ho, P C; Chow, Y Y

    2011-08-01

    Arthroscopic surgery has become the gold standard for the diagnosis and treatment of major joint disorders. With advancement in arthroscopic technique, arthroscopy has become feasible in most human joints, even those as small as the finger joints. The metacarpophalangeal joint (MCPJ) can become spacious with simple traction, the intra-articular anatomy is simple, and its major structures can be easily visualized and identified. However, MCPJ arthroscopy has never been popular. This article describes our experience with MCPJ arthroscopy and seeks to establish its role in clinical practice. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Effects of joint mobilization on chronic ankle instability: a randomized controlled trial.

    PubMed

    Cruz-Díaz, David; Lomas Vega, Rafael; Osuna-Pérez, Maria Catalina; Hita-Contreras, Fidel; Martínez-Amat, Antonio

    2015-01-01

    To evaluate the effects of joint mobilization, in which movement is applied to the ankle's dorsiflexion range of motion, on dynamic postural control and on the self-reported instability of patients with chronic ankle instability (CAI). A double-blind, placebo-controlled, randomized trial with repeated measures and a follow-up period. Ninety patients with a history of recurrent ankle sprain, self-reported instability, and a limited dorsiflexion range of motion, were randomly assigned to either the intervention group (Joint Mobilizations, 3 weeks, two sessions per week) the placebo group (Sham Mobilizations, same duration as joint mobilization) or the control group, with a 6 months follow-up. Dorsiflexion Range of Motion (DFROM), Star Excursion Balance Test (SEBT) and CAI Tool (CAIT) were outcome measures. A separate 3 × 4 mixed model analysis of variance was performed to examine the effect of treatment conditions and time, and intention-to-treat (ITT) analysis was applied to evaluate the effect of the independent variable. The application of joint mobilization resulted in better scores of DFROM, CAIT, and SEBTs in the intervention group when compared with the placebo or the control groups (p < 0.001). The effect sizes of group-by-time interaction, measured with eta-squared, oscillated between 0.954 for DFROM and 0.288 for SEBT posteromedial distance. In within-group analysis, the manipulation group showed an improvement at 6 months follow-up in CAIT [mean = 5.23, CI 95% (4.63-5.84)], DFROM [mean = 6.77, CI 95% (6.45-7.08)], anterior SEBT [mean = 7.35, CI 95% (6.59-8.12)], posteromedial SEBT [mean = 3.32, CI 95% (0.95-5.69)], and posterolateral SEBT [mean = 2.55, CI 95% (2.20-2.89)]. Joint mobilization techniques applied to subjects suffering from CAI were able to improve ankle DFROM, postural control, and self-reported instability. These results suggest that joint mobilization could be applied to patients with recurrent ankle sprain to help restore their functional stability. Implications for Rehabilitation Functional instability is a very common sequela in patients with CAI, resulting in reduced quality of living due to the limitations it imposes on daily life activities. The mobilization with movement technique presented by Mulligan, and based on the joint mobilization accompanied by active movement, appears as a valuable tool to be employed by physical therapists to restore ankle function after a recurrent ankle sprain history. ROM restriction, subjective feeling of instability and dynamic postural control are benefiting from the joint mobilization application.

  8. Mechanical Behavior of Steel Fiber-Reinforced Concrete Beams Bonded with External Carbon Fiber Sheets

    PubMed Central

    Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K.; Gudonis, Eugenijus; Misiunaite, Ieva

    2017-01-01

    This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets. PMID:28773024

  9. Mechanical Behavior of Steel Fiber-Reinforced Concrete Beams Bonded with External Carbon Fiber Sheets.

    PubMed

    Gribniak, Viktor; Tamulenas, Vytautas; Ng, Pui-Lam; Arnautov, Aleksandr K; Gudonis, Eugenijus; Misiunaite, Ieva

    2017-06-17

    This study investigates the mechanical behavior of steel fiber-reinforced concrete (SFRC) beams internally reinforced with steel bars and externally bonded with carbon fiber-reinforced polymer (CFRP) sheets fixed by adhesive and hybrid jointing techniques. In particular, attention is paid to the load resistance and failure modes of composite beams. The steel fibers were used to avoiding the rip-off failure of the concrete cover. The CFRP sheets were fixed to the concrete surface by epoxy adhesive as well as combined with various configurations of small-diameter steel pins for mechanical fastening to form a hybrid connection. Such hybrid jointing techniques were found to be particularly advantageous in avoiding brittle debonding failure, by promoting progressive failure within the hybrid joints. The use of CFRP sheets was also effective in suppressing the localization of the discrete cracks. The development of the crack pattern was monitored using the digital image correlation method. As revealed from the image analyses, with an appropriate layout of the steel pins, brittle failure of the concrete-carbon fiber interface could be effectively prevented. Inverse analysis of the moment-curvature diagrams was conducted, and it was found that a simplified tension-stiffening model with a constant residual stress level at 90% of the strength of the SFRC is adequate for numerically simulating the deformation behavior of beams up to the debonding of the CFRP sheets.

  10. Cell therapy in joint disorders.

    PubMed

    Counsel, Peter D; Bates, Daniel; Boyd, Richard; Connell, David A

    2015-01-01

    Articular cartilage possesses poor natural healing mechanisms, and a variety of non-cell-based and cell-based treatments aim to promote regeneration of hyaline cartilage. A review of the literature to December 2013 using PubMed with search criteria including the keywords stem cell, cell therapy, cell transplantation, cartilage, chondral, and chondrogenic. Forty-five articles were identified that employed local mesenchymal stem cell (MSC) therapy for joint disorders in humans. Nine comparative studies were identified, consisting of 3 randomized trials, 5 cohort studies, and 1 case-control study. Clinical review. Level 4. Studies were assessed for stem cell source, method of implantation, comparison groups, and concurrent surgical techniques. Two studies comparing MSC treatment to autologous chondrocyte implantation found similar efficacy. Three studies reported clinical benefits with intra-articular MSC injection over non-MSC controls for cases undergoing debridement with or without marrow stimulation, although a randomized study found no significant clinical difference at 2-year follow-up but reported better 18-month magnetic resonance imaging and histologic scores in the MSC group. No human studies have compared intra-articular MSC therapy to non-MSC techniques for osteoarthritis in the absence of surgery. Mesenchymal stem cell-based therapies appear safe and effective for joint disorders in large animal preclinical models. Evidence for use in humans, particularly, comparison with more established treatments such as autologous chondrocyte implantation and microfracture, is limited.

  11. Function-specific and Enhanced Brain Structural Connectivity Mapping via Joint Modeling of Diffusion and Functional MRI.

    PubMed

    Chu, Shu-Hsien; Parhi, Keshab K; Lenglet, Christophe

    2018-03-16

    A joint structural-functional brain network model is presented, which enables the discovery of function-specific brain circuits, and recovers structural connections that are under-estimated by diffusion MRI (dMRI). Incorporating information from functional MRI (fMRI) into diffusion MRI to estimate brain circuits is a challenging task. Usually, seed regions for tractography are selected from fMRI activation maps to extract the white matter pathways of interest. The proposed method jointly analyzes whole brain dMRI and fMRI data, allowing the estimation of complete function-specific structural networks instead of interactively investigating the connectivity of individual cortical/sub-cortical areas. Additionally, tractography techniques are prone to limitations, which can result in erroneous pathways. The proposed framework explicitly models the interactions between structural and functional connectivity measures thereby improving anatomical circuit estimation. Results on Human Connectome Project (HCP) data demonstrate the benefits of the approach by successfully identifying function-specific anatomical circuits, such as the language and resting-state networks. In contrast to correlation-based or independent component analysis (ICA) functional connectivity mapping, detailed anatomical connectivity patterns are revealed for each functional module. Results on a phantom (Fibercup) also indicate improvements in structural connectivity mapping by rejecting false-positive connections with insufficient support from fMRI, and enhancing under-estimated connectivity with strong functional correlation.

  12. Relative efficiency of joint-model and full-conditional-specification multiple imputation when conditional models are compatible: The general location model.

    PubMed

    Seaman, Shaun R; Hughes, Rachael A

    2018-06-01

    Estimating the parameters of a regression model of interest is complicated by missing data on the variables in that model. Multiple imputation is commonly used to handle these missing data. Joint model multiple imputation and full-conditional specification multiple imputation are known to yield imputed data with the same asymptotic distribution when the conditional models of full-conditional specification are compatible with that joint model. We show that this asymptotic equivalence of imputation distributions does not imply that joint model multiple imputation and full-conditional specification multiple imputation will also yield asymptotically equally efficient inference about the parameters of the model of interest, nor that they will be equally robust to misspecification of the joint model. When the conditional models used by full-conditional specification multiple imputation are linear, logistic and multinomial regressions, these are compatible with a restricted general location joint model. We show that multiple imputation using the restricted general location joint model can be substantially more asymptotically efficient than full-conditional specification multiple imputation, but this typically requires very strong associations between variables. When associations are weaker, the efficiency gain is small. Moreover, full-conditional specification multiple imputation is shown to be potentially much more robust than joint model multiple imputation using the restricted general location model to mispecification of that model when there is substantial missingness in the outcome variable.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syracuse, E. M.; Maceira, M.; Zhang, H.

    Joint inversions of seismic data recover models that simultaneously fit multiple constraints while playing upon the strengths of each data type. Here, we jointly invert 14 years of local earthquake body wave arrival times from the Alaska Volcano Observatory catalog and Rayleigh wave dispersion curves based upon ambient noise measurements for local V p, V s, and hypocentral locations at Akutan and Makushin Volcanoes using a new joint inversion algorithm.The velocity structure and relocated seismicity of both volcanoes are significantly more complex than many other volcanoes studied using similar techniques. Seismicity is distributed among several areas beneath or beyond themore » flanks of both volcanoes, illuminating a variety of volcanic and tectonic features. The velocity structures of the two volcanoes are exemplified by the presence of narrow high-V p features in the near surface, indicating likely current or remnant pathways of magma to the surface. A single broad low-V p region beneath each volcano is slightly offset from each summit and centered at approximately 7 km depth, indicating a potential magma chamber, where magma is stored over longer time periods. Differing recovery capabilities of the Vp and Vs datasets indicate that the results of these types of joint inversions must be interpreted carefully.« less

  14. LOW ACTIVATION JOINING OF SIC/SIC COMPOSITES FOR FUSION APPLICATIONS: MODELING DUAL-PHASE MICROSTRUCTURES AND DISSIMILAR MATERIAL JOINTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henager, Charles H.; Nguyen, Ba Nghiep; Kurtz, Richard J.

    2016-03-31

    Finite element continuum damage models (FE-CDM) have been developed to simulate and model dual-phase joints and cracked joints for improved analysis of SiC materials in nuclear environments. This report extends the analysis from the last reporting cycle by including results from dual-phase models and from cracked joint models.

  15. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  16. A biomechanical comparison between expert and novice manual materials handlers using a multi-joint EMG-assisted optimization musculoskeletal model of the lumbar spine.

    PubMed

    Gagnon, Denis; Plamondon, André; Larivière, Christian

    2016-09-06

    Expertise is a key factor modulating the risk of low back disorders (LBD). Through years of practice in the workplace, the typical expert acquires high level specific skills and maintains a clean record of work-related injuries. Ergonomic observations of manual materials handling (MMH) tasks show that expert techniques differ from those of novices, leading to the idea that expert techniques are safer. Biomechanical studies of MMH tasks performed by experts/novices report mixed results for kinematic/kinetic variables, evoking potential internal effect of expertise. In the context of series of box transfers simulated by actual workers, detailed internal loads predicted by a multiple-joint EMG-assisted optimization lumbar spine model are compared between experts and novices. The results confirmed that the distribution of internal moments are modulated by worker expertise. Experts flexed less their lumbar spine and exerted more active muscle forces while novices relied more on passive resistance of the muscles and ligamentous spine. More specifically for novices, the passive contributions came from global extensor muscles, selected local extensor muscles, and passive structures of the lumbar spine (ligaments and discs). The distinctive distribution of internal forces was not concomitant with a similar effect on joint forces, these forces being dependent on external loading which was equivalent between experts and novices. From a safety standpoint, the present results suggest that experts were more efficient than novices in partitioning internal moment contributions to balance net (external) loading. Thus, safer handling practices might be seen as a result of experts׳ experience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. The Influence of Foot-Strike Technique on the Neuromechanical Function of the Foot.

    PubMed

    Kelly, Luke A; Farris, Dominic J; Lichtwark, Glen A; Cresswell, Andrew G

    2018-01-01

    The aim of this study was to investigate the influence of foot-strike technique on longitudinal arch mechanics and intrinsic foot muscle function during running. Thirteen healthy participants ran barefoot on a force-instrumented treadmill at 2.8 ms with a forefoot (FFS) and rearfoot (RFS; habitual) running technique, whereas kinetic, kinematic, and electromyographic data from the intrinsic foot muscles were collected simultaneously. The longitudinal arch was modeled as a single "midfoot" joint representing motion of the rearfoot (calcaneus) relative to the forefoot (metatarsals). An inverse dynamic analysis was performed to estimate joint moments generated about the midfoot, as well as mechanical work and power. The midfoot was more plantar flexed (higher arch) at foot contact when running with a forefoot running technique (RFS 0.2 ± 1.8 vs FFS 6.9 ± 3.0°, effect size (ES) = 2.7); however, there was no difference in peak midfoot dorsiflexion in stance (RFS -11.6 ± 3.0 vs FFS -11.4 ± 3.4°, ES = 0.63). When running with a forefoot technique, participants generated greater moments about the midfoot (27% increase, ES = 1.1) and performed more negative work (240% increase, ES = 2.2) and positive work (42% increase, ES = 1.1) about the midfoot. Average stance-phase muscle activation was greater for flexor digitorum brevis (20% increase, ES = 0.56) and abductor hallucis (17% increase, ES = 0.63) when running with a forefoot technique. Forefoot running increases loading about the longitudinal arch and also increases the mechanical work performed by the intrinsic foot muscles. These findings have substantial implications in terms of injury prevention and management for runners who transition from a rearfoot to a forefoot running technique.

  18. Modeling Progressive Failure of Bonded Joints Using a Single Joint Finite Element

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Bednarcyk, Brett A.

    2010-01-01

    Enhanced finite elements are elements with an embedded analytical solution which can capture detailed local fields, enabling more efficient, mesh-independent finite element analysis. In the present study, an enhanced finite element is applied to generate a general framework capable of modeling an array of joint types. The joint field equations are derived using the principle of minimum potential energy, and the resulting solutions for the displacement fields are used to generate shape functions and a stiffness matrix for a single joint finite element. This single finite element thus captures the detailed stress and strain fields within the bonded joint, but it can function within a broader structural finite element model. The costs associated with a fine mesh of the joint can thus be avoided while still obtaining a detailed solution for the joint. Additionally, the capability to model non-linear adhesive constitutive behavior has been included within the method, and progressive failure of the adhesive can be modeled by using a strain-based failure criteria and re-sizing the joint as the adhesive fails. Results of the model compare favorably with experimental and finite element results.

  19. Automated muscle wrapping using finite element contact detection.

    PubMed

    Favre, Philippe; Gerber, Christian; Snedeker, Jess G

    2010-07-20

    Realistic muscle path representation is essential to musculoskeletal modeling of joint function. Algorithms predicting these muscle paths typically rely on a labor intensive predefinition of via points or underlying geometries to guide wrapping for given joint positions. While muscle wrapping using anatomically precise three-dimensional (3D) finite element (FE) models of bone and muscle has been achieved, computational expense and pre-processing associated with this approach exclude its use in applications such as subject-specific modeling. With the intention of combining advantageous features of both approaches, an intermediate technique relying on contact detection capabilities of commercial FE packages is presented. We applied the approach to the glenohumeral joint, and validated the method by comparison against existing experimental data. Individual muscles were modeled as a straight series of deformable beam elements and bones as anatomically precise 3D rigid bodies. Only the attachment locations and a default orientation of the undeformed muscle segment were pre-defined. The joint was then oriented in a static position of interest. The muscle segment free end was then moved along the shortest Euclidean path to its origin on the scapula, wrapping the muscle along bone surfaces by relying on software contact detection. After wrapping for a given position, the resulting moment arm was computed as the perpendicular distance from the line of action vector to the humeral head center of rotation. This approach reasonably predicted muscle length and moment arm for 27 muscle segments when compared to experimental measurements over a wide range of shoulder motion. Artificial via points or underlying contact geometries were avoided, contact detection and multiobject wrapping on the bone surfaces were automatic, and low computational cost permitted wrapping of individual muscles within seconds on a standard desktop PC. These advantages may be valuable for both general and subject-specific musculoskeletal modeling. 2010 Elsevier Ltd. All rights reserved.

  20. Preserving transfer independence among individuals with spinal cord injury.

    PubMed

    Nyland, J; Quigley, P; Huang, C; Lloyd, J; Harrow, J; Nelson, A

    2000-11-01

    Literature review. Upper extremity (UE) joint degeneration, particularly at the shoulder, detrimentally influences functional independence, quality of life, cardiovascular disease risk, and life expectancy of individuals following spinal cord injury (SCI). This review (1) describes UE use for transfers among individuals with SCI; (2) describes contributing factors associated with UE joint degeneration and loss of transfer independence; (3) summarizes and identifies gaps in existing research; and (4) provides suggestions for future research. Investigations of wheelchair transfer related UE joint and function preservation among individuals with SCI should consider factors including age and length of time from SCI onset, interface between subject-wheelchair, pain, shoulder joint range of motion (ROM) and muscle strength deficiencies or imbalances, exercise capacity and tolerance for the physical strain of activities of daily living (ADL), body mass and composition, previous UE injury or disease history, and transfer techniques. Existing studies of transfers among individuals with SCI have relied on small groups of either asymptomatic or non-impaired subjects, with minimal integration of kinematic, kinetic and electromyographic data. Descriptions of UE joint ROM, forces, and moments produced during transfers are lacking. Biomechanical measurement and computer modeling have provided increasingly accurate tools for acquiring the data needed to guide intervention planning to prevent UE joint degeneration and preserve function among individuals with SCI. The identification of stressful sub-components during transfers will enable intervening clinicians and engineers who design and modify assistive and adaptive devices to better serve individuals with SCI.

  1. EFFECT OF HEEL LIFTS ON PATELLOFEMORAL JOINT STRESS DURING RUNNING.

    PubMed

    Mestelle, Zachary; Kernozek, Thomas; Adkins, Kelly S; Miller, Jessica; Gheidi, Naghmeh

    2017-10-01

    Patellofemoral pain is a debilitating injury for many recreational runners. Excessive patellofemoral joint stress may be the underlying source of pain and interventions often focus on ways to reduce patellofemoral joint stress. Heel lifts have been used as an intervention within Achilles tendon rehabilitation programs and to address leg length discrepancies. The purpose of this study was to examine the effect of running with heel lifts on patellofemoral joint stress, patellofemoral stress impulse, quadriceps force, step length, cadence, and other related kinematic and spatiotemporal variables. A repeated-measures research design. Sixteen healthy female runners completed five running trials in a controlled laboratory setting with and without 11mm heel lifts inserted in a standard running shoe. Kinetic and kinematic data were used in combination with a static optimization technique to estimate individual muscle forces. These data were inserted into a patellofemoral joint model which was used to estimate patellofemoral joint stress and other variables during running. When running with heel lifts, peak patellofemoral joint stress and patellofemoral stress impulse were reduced by a 4.2% (p=0.049) and 9.3% (p=0.002). Initial center of pressure was shifted anteriorly 9.1% when running with heel lifts (p<0.001) despite all runners utilizing a heel strike pattern. Dorsiflexion at initial contact was reduced 28% (p=0.016) when heel lifts were donned. No differences in step length and cadence (p>0.05) were shown between conditions. Heel lift use resulted in decreased patellofemoral joint stress and impulse without associated changes in step length or frequency, or other variables shown to influence patellofemoral joint stress. The center of pressure at initial contact was also more anterior using heel lifts. The use of heel lifts may have therapeutic benefits for runners with patellofemoral pain if the primary goal is to reduce patellofemoral joint stress. 3b.

  2. Acromioclavicular joint dislocations: coracoclavicular reconstruction with and without additional direct acromioclavicular repair.

    PubMed

    Weiser, Lukas; Nüchtern, Jakob V; Sellenschloh, Kay; Püschel, Klaus; Morlock, Michael M; Rueger, Johannes M; Hoffmann, Michael; Lehmann, Wolfgang; Großterlinden, Lars G

    2017-07-01

    To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.

  3. EFFECT OF HEEL LIFTS ON PATELLOFEMORAL JOINT STRESS DURING RUNNING

    PubMed Central

    Mestelle, Zachary; Kernozek, Thomas; Adkins, Kelly S.; Miller, Jessica; Gheidi, Naghmeh

    2017-01-01

    Background Patellofemoral pain is a debilitating injury for many recreational runners. Excessive patellofemoral joint stress may be the underlying source of pain and interventions often focus on ways to reduce patellofemoral joint stress. Purpose Heel lifts have been used as an intervention within Achilles tendon rehabilitation programs and to address leg length discrepancies. The purpose of this study was to examine the effect of running with heel lifts on patellofemoral joint stress, patellofemoral stress impulse, quadriceps force, step length, cadence, and other related kinematic and spatiotemporal variables. Study Design A repeated-measures research design Methods Sixteen healthy female runners completed five running trials in a controlled laboratory setting with and without 11mm heel lifts inserted in a standard running shoe. Kinetic and kinematic data were used in combination with a static optimization technique to estimate individual muscle forces. These data were inserted into a patellofemoral joint model which was used to estimate patellofemoral joint stress and other variables during running. Results When running with heel lifts, peak patellofemoral joint stress and patellofemoral stress impulse were reduced by a 4.2% (p=0.049) and 9.3% (p=0.002). Initial center of pressure was shifted anteriorly 9.1% when running with heel lifts (p<0.001) despite all runners utilizing a heel strike pattern. Dorsiflexion at initial contact was reduced 28% (p=0.016) when heel lifts were donned. No differences in step length and cadence (p>0.05) were shown between conditions. Conclusions Heel lift use resulted in decreased patellofemoral joint stress and impulse without associated changes in step length or frequency, or other variables shown to influence patellofemoral joint stress. The center of pressure at initial contact was also more anterior using heel lifts. The use of heel lifts may have therapeutic benefits for runners with patellofemoral pain if the primary goal is to reduce patellofemoral joint stress. Level of Evidence 3b PMID:29181248

  4. Advanced Fabrication Techniques for Precisely Controlled Micro and Nano Scale Environments for Complex Tissue Regeneration and Biomedical Applications

    NASA Astrophysics Data System (ADS)

    Holmes, Benjamin

    As modern medicine advances, it is still very challenging to cure joint defects due to their poor inherent regenerative capacity, complex stratified architecture, and disparate biomechanical properties. The current clinical standard for catastrophic or late stage joint degradation is a total joint implant, where the damaged joint is completely excised and replaced with a metallic or artificial joint. However, these procedures still only lasts for 10-15 years, and there are hosts of recovery complications which can occur. Thus, these studies have sought to employ advanced biomaterials and scaffold fabricated techniques to effectively regrow joint tissue, instead of merely replacing it with artificial materials. We can hypothesize here that the inclusion of biomimetic and bioactive nanomaterials with highly functional electrospun and 3D printed scaffold can improve physical characteristics (mechanical strength, surface interactions and nanotexture) enhance cellular growth and direct stem cell differentiation for bone, cartilage and vascular growth as well as cancer metastasis modeling. Nanomaterial inclusion and controlled 3D printed features effectively increased nano surface roughness, Young's Modulus and provided effective flow paths for simulated arterial blood. All of the approaches explored proved highly effective for increasing cell growth, as a result of increasing micro-complexity and nanomaterial incorporation. Additionally, chondrogenic and osteogenic differentiation, cell migration, cell to cell interaction and vascular formation were enhanced. Finally, growth-factor(gf)-loaded polymer nanospheres greatly improved vascular cell behavior, and provided a highly bioactive scaffold for mesenchymal stem cell (MSC) and human umbilical vein endothelial cell (HUVEC) co-culture and bone formation. In conclusion, electrospinning and 3D printing when combined effectively with biomimetic and bioactive nanomaterials (i.e. carbon nanomaterials, collagen, nHA, polymer drug delivery nanospheres) can provide high performance, functional materials that also serve as effective tissue forming 3D environments. Both general science knowledge and the translational potential of tissue engineered constructs were advanced by original contributions to the fields for tissue engineering and orthopedic medicine. The most original advancement of general science comes from a successful combination of advanced nanomaterials and biomaterials with existing 3D printing and CAD design to support multiple types of cells and tissues. Future translation of these technologies was advanced due to the highly functional nature of these constructs (i.e. mechanical and hydrodynamic characteristics). Future work would involve more evaluation of vascular neogenesis, small animal models to evaluate bioactivity and biocompatibility and large clinically relevant animals to measure gross tissue formation and biomechanical performance.

  5. Local fibroblast proliferation but not influx is responsible for synovial hyperplasia in a murine model of rheumatoid arthritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuo, Yusuke; Mizoguchi, Fumitaka; Saito, Tetsuya

    Synovial fibroblasts play crucial roles in inflammation and joint destruction in rheumatoid arthritis (RA). How they accumulate in the RA joints remains unclear. This study was conducted to discern whether cellular influx from the outside of the joints and local proliferation are responsible for synovial fibroblast accumulation in an animal model of RA. We found that synovial fibroblasts were identified as GFP+ cells using collagen type I alpha 2 (Col1a2)-GFP transgenic reporter mice. Then, bone marrow transplantation and parabiosis techniques were utilized to study the cellular influx. Irradiated wild-type mice were transplanted with bone marrow from Col1a2-GFP mice. Col1a2-GFP andmore » wild-type mice were conjoined for parabiosis. The transplanted mice and the parabionts were subjected to collagen antibody-induced arthritis (CAIA). We found no GFP+ cells in the hyperplastic synovial tissues from the transplanted mice with CAIA and from the wild-type parabionts with CAIA. Furthermore, normal and CAIA synovial tissues from Col1a2-GFP mice and from fluorescent ubiquitination-based cell cycle indicator (Fucci) transgenic mice, in which cells in S/G{sub 2}/M phases of the cell cycle express Azami-Green, were studied for Ki67, a cellular proliferation marker, and vimentin, a fibroblast marker, expression. The percentages of Ki67+/GFP+ and Azami-Green+/vimentin+ cells in the CAIA synovial tissues were higher than those in the untreated synovial tissues (34% vs. 0.40% and 19% vs. 0.26%, respectively). These findings indicate that local fibroblast proliferation but not cellular influx is responsible for the synovial hyperplasia in CAIA. Suppression of proliferation of the local synovial fibroblasts should be a promising treatment for RA. - Highlights: • We studied how synovial fibroblasts accumulate in joints in a murine model of RA. • Bone marrow-derived cells did not accumulate in arthritic joints. • Synovial fibroblasts did not accumulate in arthritic joints via circulation. • Local proliferation was responsible for the synovial fibroblast accumulation.« less

  6. Mechanical characterization and validation of poly (methyl methacrylate)/multi walled carbon nanotube composite for the polycentric knee joint.

    PubMed

    Arun, S; Kanagaraj, S

    2015-10-01

    Trans femoral amputation is one of the most uncomfortable surgeries in patient׳s life, where the prosthesis consisting of a socket, knee joint, pylon and foot is used to do the walking activities. The artificial prosthetic knee joint imitates the functions of human knee to achieve the flexion-extension for the above knee amputee. The objective of present work is to develop a light weight composite material for the knee joint to reduce the metabolic cost of an amputee. Hence, an attempt was made to study the mechanical properties of multi walled carbon nanotubes (MWCNT) reinforced Poly (methyl methacrylate) (PMMA) prepared through melt mixing technique and optimize the concentration of reinforcement. The PMMA nanocomposites were prepared by reinforcing 0, 0.1, 0.2, 0.25, 0.3 and 0.4 wt% of MWCNT using injection moulding machine via twin screw extruder. It is observed that the tensile and flexural strength of PMMA, which were studied as per ASTM D638 and D790, respectively, were increased by 32.9% and 26.3% till 0.25 wt% reinforcement of MWCNT. The experimental results of strength and modulus were compared with theoretical prediction, where a good correlation was noted. It is concluded that the mechanical properties of PMMA were found to be increased to maximum at 0.25 wt% reinforcement of MWCNT, where the Pukanszky model and modified Halpin-Tsai model are suggested to predict the strength and modulus, respectively, of the PMMA/MWCNT composite, which can be opted as a suitable materiel for the development of polycentric knee joint. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Practical approach to subject-specific estimation of knee joint contact force.

    PubMed

    Knarr, Brian A; Higginson, Jill S

    2015-08-20

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data; however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models' predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Hallux rigidus: How do I approach it?

    PubMed Central

    Lam, Aaron; Chan, Jimmy J; Surace, Michele F; Vulcano, Ettore

    2017-01-01

    Hallux rigidus is a degenerative disease of the first metatarsalphalangeal (MTP) joint and affects 2.5% of people over age 50. Dorsal osteophytes and narrowed joint space leads to debilitating pain and limited range of motion. Altered gait mechanics often ensued as 119% of the body force transmit through the 1st MTP joint during gait cycle. Precise etiology remains under debate with trauma being often cited in the literature. Hallux valgus interphalangeus, female gender, inflammatory and metabolic conditions have all been identified as associative factors. Clinical symptoms, physical exam and radiographic evidence are important in assessing and grading the disease. Non-operative managements including nonsteroidal antiinflammatory drugs, intra-articular injections, shoe modification, activity modification and physical therapy, should always be attempted for all hallux rigidus patients. The goal of surgery is to relieve pain, maintain stability of the first MTP joint, and improve function and quality of life. Operative treatments can be divided into joint-sparing vs joint-sacrificing. Cheilectomy and moberg osteotomy are examples of joint-sparing techniques that have demonstrated great success in early stages of hallux rigidus. Arthrodesis is a joint-sacrificing procedure that has been the gold standard for advanced hallux rigidus. Other newer procedures such as implant arthroplasty, interpositional arthroplasty and arthroscopy, have demonstrated promising early patient outcomes. However, future studies are still needed to validate its long-term efficacy and safety. The choice of procedure should be based on the condition of the joint, patient’s goal and expectations, and surgeon’s experience with the technique. PMID:28567339

  9. Ultrasound-guided corticosteroid injection of the subtalar joint for treatment of juvenile idiopathic arthritis.

    PubMed

    Young, Cody M; Horst, Deanna M; Murakami, James W; Shiels, William E

    2015-07-01

    The subtalar joint is commonly affected in children with juvenile idiopathic arthritis and is challenging to treat percutaneously. To describe the technique for treating the subtalar joint with US-guided corticosteroid injections in children and young adults with juvenile idiopathic arthritis and to evaluate the safety of the treatment. We retrospectively analyzed 122 patients (age 15 months-29 years) with juvenile idiopathic arthritis who were referred by a pediatric rheumatologist for corticosteroid injection therapy for symptoms related to the hindfoot or ankle. In these patients the diseased subtalar joint was targeted for therapy, often in conjunction with adjacent affected joints or tendon sheaths of the ankle. We used a protocol based on age, weight and joint for triamcinolone hexacetonide or triamcinolone acetonide dose prescription. We describe the technique for successful treatment of the subtalar joint. A total of 241 subtalar joint corticosteroid injections were performed under US guidance, including 68 repeat injections for recurrent symptoms in 26 of the 122 children and young adults. The average time interval between repeat injections was 24.8 months (range 2.2-130.7 months, median 14.2 months). Subcutaneous tissue atrophy and skin hypopigmentation were the primary complications observed. These complications occurred in 3.9% of the injections. With appropriate training and practice, the subtalar joint can be reliably and safely targeted with US-guided corticosteroid injection to treat symptoms related to juvenile idiopathic arthritis.

  10. Temporomandibular joint arthroscopy technique using a single working cannula.

    PubMed

    Srouji, S; Oren, D; Zoabi, A; Ronen, O; Zraik, H

    2016-11-01

    The traditional arthroscopy technique includes the creation of three ports in order to enable visualization, operation, and arthrocentesis. The aim of this study was to assess an advanced temporomandibular joint (TMJ) arthroscopy technique that requires only a single cannula, through which a one-piece instrument containing a visualization canal, irrigation canal, and a working canal is inserted, as an alternative to the traditional double-puncture technique. This retrospective study assessed eight patients (13 TMJs) with pain and/or limited range of movement that was refractory to conservative therapy, who were treated between June 2015 and December 2015. The temporomandibular joint disorder (TMD) was diagnosed by physical examination and mouth opening measurements. The duration of surgery was recorded and compared to that documented for traditional arthroscopies performed by the same surgeon. Operative single-cannula arthroscopy (OSCA) was performed using a holmium YAG (Ho:YAG) 230μm fibre laser for ablation. The OSCA technique proved effective in improving mouth opening in all patients (mean increase 9.12±1.96mm) and in reducing pain (mean visual analogue scale decrease of 3.25±1.28). The operation time was approximately half that of the traditional technique. The OSCA technique is as efficient as the traditional technique, is simple to learn, and is simpler to execute. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner

    PubMed Central

    Muhit, A. A.; Arora, S.; Ogawa, M.; Ding, Y.; Zbijewski, W.; Stayman, J. W.; Thawait, G.; Packard, N.; Senn, R.; Yang, D.; Yorkston, J.; Bingham, C.O.; Means, K.; Carrino, J. A.; Siewerdsen, J. H.

    2014-01-01

    Purpose We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. Methods A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). Results The CBCT extremity scanner yielded BMD measurement within ±2–3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. Conclusion The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from images acquired with each CBCT scan. Future studies will include improved x-ray scatter correction and image reconstruction techniques to further improve accuracy and to correlate pQCT metrics with known pathology. PMID:25076823

  12. Space, time, and the third dimension (model error)

    USGS Publications Warehouse

    Moss, Marshall E.

    1979-01-01

    The space-time tradeoff of hydrologic data collection (the ability to substitute spatial coverage for temporal extension of records or vice versa) is controlled jointly by the statistical properties of the phenomena that are being measured and by the model that is used to meld the information sources. The control exerted on the space-time tradeoff by the model and its accompanying errors has seldom been studied explicitly. The technique, known as Network Analyses for Regional Information (NARI), permits such a study of the regional regression model that is used to relate streamflow parameters to the physical and climatic characteristics of the drainage basin.The NARI technique shows that model improvement is a viable and sometimes necessary means of improving regional data collection systems. Model improvement provides an immediate increase in the accuracy of regional parameter estimation and also increases the information potential of future data collection. Model improvement, which can only be measured in a statistical sense, cannot be quantitatively estimated prior to its achievement; thus an attempt to upgrade a particular model entails a certain degree of risk on the part of the hydrologist.

  13. Effects of joints in truss structures

    NASA Technical Reports Server (NTRS)

    Ikegami, R.

    1988-01-01

    The response of truss-type structures for future space applications, such as Large Deployable Reflector (LDR), will be directly affected by joint performance. Some of the objectives of research at BAC were to characterize structural joints, establish analytical approaches that incorporate joint characteristics, and experimentally establish the validity of the analytical approaches. The test approach to characterize joints for both erectable and deployable-type structures was based upon a Force State Mapping Technique. The approach pictorially shows how the nonlinear joint results can be used for equivalent linear analysis. Testing of the Space Station joints developed at LaRC (a hinged joint at 2 Hz and a clevis joint at 2 Hz) successfully revealed the nonlinear characteristics of the joints. The Space Station joints were effectively linear when loaded to plus or minus 500 pounds with a corresponding displacement of about plus or minus 0.0015 inch. It was indicated that good linear joints exist which are compatible with errected structures, but that difficulty may be encountered if nonlinear-type joints are incorporated in the structure.

  14. Numerical Model for the Study of the Strength and Failure Modes of Rock Containing Non-Persistent Joints

    NASA Astrophysics Data System (ADS)

    Vergara, Maximiliano R.; Van Sint Jan, Michel; Lorig, Loren

    2016-04-01

    The mechanical behavior of rock containing parallel non-persistent joint sets was studied using a numerical model. The numerical analysis was performed using the discrete element software UDEC. The use of fictitious joints allowed the inclusion of non-persistent joints in the model domain and simulating the progressive failure due to propagation of existing fractures. The material and joint mechanical parameters used in the model were obtained from experimental results. The results of the numerical model showed good agreement with the strength and failure modes observed in the laboratory. The results showed the large anisotropy in the strength resulting from variation of the joint orientation. Lower strength of the specimens was caused by the coalescence of fractures belonging to parallel joint sets. A correlation was found between geometrical parameters of the joint sets and the contribution of the joint sets strength in the global strength of the specimen. The results suggest that for the same dip angle with respect to the principal stresses; the uniaxial strength depends primarily on the joint spacing and the angle between joints tips and less on the length of the rock bridges (persistency). A relation between joint geometrical parameters was found from which the resulting failure mode can be predicted.

  15. Biomechanical benefits of anterior offsetting of humeral head component in posteriorly unstable total shoulder arthroplasty: A cadaveric study.

    PubMed

    Kim, Hyun-Min Mike; Chacon, Alexander C; Andrews, Seth H; Roush, Evan P; Cho, Edward; Conaway, William K; Kunselman, Allen R; Lewis, Gregory S

    2016-04-01

    Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders from 7 donors. Complementary shoulders were assigned to either 10° or 20° glenoid retroversion, with retroversion created by eccentric reaming. Two humeral head component offset positions were tested in each specimen: The anatomic (posterior) and anterior (reverse). With loads applied to the rotator cuff and deltoid, joint contact pressures and the force and energy required for posterior humeral head translation were measured. The force and energy required to displace the humeral head posteriorly increased significantly with the anterior offset position compared to the anatomic offset position. The joint contact pressures were significantly shifted anteriorly, and the joint contact area significantly increased with the anterior offset position. Anterior offsetting of the humeral head component increased the resistance to posterior humeral head translation, shifted joint contact pressures anteriorly, and increased joint contact area, thus, potentially increasing the joint stability in total shoulder arthroplasty with simulated glenoid retroversion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Intraarticular Pulsed Radiofrequency to Treat Refractory Lumbar Facet Joint Pain in Patients with Low Back Pain.

    PubMed

    Chang, Min Cheol; Cho, Yun-Woo; Ahn, Da Hyun; Do, Kyung Hee

    2018-04-01

    Many treatment techniques have been used for refractory lumbar facet joint pain; however, their efficacy has been controversial. In this study, we investigated the clinical efficacy and safety of intra-articular pulsed radiofrequency for the treatment of refractory lumbar facet joint pain in patients with low back pain. Twenty patients with refractory lumbar facet joint pain were recruited, and each patient was treated via intra-articular pulsed radiofrequency. The treatment effects were measured with a numerical rating scale, and the technical accuracy of intra-articular pulsed radiofrequency treatment was evaluated independently by 2 radiologists. Any adverse events or complications also were checked. We performed intra-articular pulsed radiofrequency treatment at 48 levels of the lumbar facet joints in 20 patients (5 men and 15 women; mean age, 64.50 ± 10.65 years) with refractory lumbar facet joint pain. Pain scores were significantly reduced at 1 month, 3 months, and 6 months after treatment (P < 0.05). The face validity revealed good intraarticular pulsed radiofrequency results in all 20 patients, without any serious adverse effects. Treatment using intra-articular pulsed radiofrequency is an alternative to other techniques in patients with refractory lumbar facet joint pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Computational Modelling and Movement Analysis of Hip Joint with Muscles

    NASA Astrophysics Data System (ADS)

    Siswanto, W. A.; Yoon, C. C.; Salleh, S. Md.; Ngali, M. Z.; Yusup, Eliza M.

    2017-01-01

    In this study, the model of hip joint and the main muscles are modelled by finite elements. The parts included in the model are hip joint, hemi pelvis, gluteus maximus, quadratus femoris and gamellus inferior. The materials that used in these model are isotropic elastic, Mooney Rivlin and Neo-hookean. The hip resultant force of the normal gait and stair climbing are applied on the model of hip joint. The responses of displacement, stress and strain of the muscles are then recorded. FEBio non-linear solver for biomechanics is employed to conduct the simulation of the model of hip joint with muscles. The contact interfaces that used in this model are sliding contact and tied contact. From the analysis results, the gluteus maximus has the maximum displacement, stress and strain in the stair climbing. Quadratus femoris and gamellus inferior has the maximum displacement and strain in the normal gait however the maximum stress in the stair climbing. Besides that, the computational model of hip joint with muscles is produced for research and investigation platform. The model can be used as a visualization platform of hip joint.

  18. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    NASA Astrophysics Data System (ADS)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  19. Non-linear homogenized and heterogeneous FE models for FRCM reinforced masonry walls in diagonal compression

    NASA Astrophysics Data System (ADS)

    Bertolesi, Elisa; Milani, Gabriele; Poggi, Carlo

    2016-12-01

    Two FE modeling techniques are presented and critically discussed for the non-linear analysis of tuff masonry panels reinforced with FRCM and subjected to standard diagonal compression tests. The specimens, tested at the University of Naples (Italy), are unreinforced and FRCM retrofitted walls. The extensive characterization of the constituent materials allowed adopting here very sophisticated numerical modeling techniques. In particular, here the results obtained by means of a micro-modeling strategy and homogenization approach are compared. The first modeling technique is a tridimensional heterogeneous micro-modeling where constituent materials (bricks, joints, reinforcing mortar and reinforcing grid) are modeled separately. The second approach is based on a two-step homogenization procedure, previously developed by the authors, where the elementary cell is discretized by means of three-noded plane stress elements and non-linear interfaces. The non-linear structural analyses are performed replacing the homogenized orthotropic continuum with a rigid element and non-linear spring assemblage (RBSM). All the simulations here presented are performed using the commercial software Abaqus. Pros and cons of the two approaches are herein discussed with reference to their reliability in reproducing global force-displacement curves and crack patterns, as well as to the rather different computational effort required by the two strategies.

  20. A mathematical model of hiking positions in a sailing dinghy.

    PubMed

    Putnam, C A

    1979-01-01

    A mathematical model of the human body designed to calculate the resultant muscle torques required at the hip and knee joints for specific hiking techniques is presented. Data for the model were obtained from ten male subjects who adopted three basic positions: Position 1 with the knees located at the inside edge of the sidedeck, Position 2 with the knees at the middle of the sidedeck, and Position 3 with the knees at the outside edge of the sidedeck. Each resultant muscle torque was expressed as a percentage of each subject's maximum voluntary hip flexion or knee extension torque. It was found that where Positions 1 and 2 were equally effective in keeping the boat upright, Position 2 was superior to Position 1 in regard to the per cent of maximum muscle torque required. The superiority of Position 2 over Position 3 depended on the individual's relative muscle strength at the hip and knee joints. The stronger the hip flexors with respect to the knee estensors, the more desirable was Position 2 and vice versa.

  1. Dynamic 3D scanning as a markerless method to calculate multi-segment foot kinematics during stance phase: methodology and first application.

    PubMed

    Van den Herrewegen, Inge; Cuppens, Kris; Broeckx, Mario; Barisch-Fritz, Bettina; Vander Sloten, Jos; Leardini, Alberto; Peeraer, Louis

    2014-08-22

    Multi-segmental foot kinematics have been analyzed by means of optical marker-sets or by means of inertial sensors, but never by markerless dynamic 3D scanning (D3DScanning). The use of D3DScans implies a radically different approach for the construction of the multi-segment foot model: the foot anatomy is identified via the surface shape instead of distinct landmark points. We propose a 4-segment foot model consisting of the shank (Sha), calcaneus (Cal), metatarsus (Met) and hallux (Hal). These segments are manually selected on a static scan. To track the segments in the dynamic scan, the segments of the static scan are matched on each frame of the dynamic scan using the iterative closest point (ICP) fitting algorithm. Joint rotations are calculated between Sha-Cal, Cal-Met, and Met-Hal. Due to the lower quality scans at heel strike and toe off, the first and last 10% of the stance phase is excluded. The application of the method to 5 healthy subjects, 6 trials each, shows a good repeatability (intra-subject standard deviations between 1° and 2.5°) for Sha-Cal and Cal-Met joints, and inferior results for the Met-Hal joint (>3°). The repeatability seems to be subject-dependent. For the validation, a qualitative comparison with joint kinematics from a corresponding established marker-based multi-segment foot model is made. This shows very consistent patterns of rotation. The ease of subject preparation and also the effective and easy to interpret visual output, make the present technique very attractive for functional analysis of the foot, enhancing usability in clinical practice. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Damage prognosis of adhesively-bonded joints in laminated composite structural components of unmanned aerial vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, Charles R; Gobbato, Maurizio; Conte, Joel

    2009-01-01

    The extensive use of lightweight advanced composite materials in unmanned aerial vehicles (UAVs) drastically increases the sensitivity to both fatigue- and impact-induced damage of their critical structural components (e.g., wings and tail stabilizers) during service life. The spar-to-skin adhesive joints are considered one of the most fatigue sensitive subcomponents of a lightweight UAV composite wing with damage progressively evolving from the wing root. This paper presents a comprehensive probabilistic methodology for predicting the remaining service life of adhesively-bonded joints in laminated composite structural components of UAVs. Non-destructive evaluation techniques and Bayesian inference are used to (i) assess the current statemore » of damage of the system and, (ii) update the probability distribution of the damage extent at various locations. A probabilistic model for future loads and a mechanics-based damage model are then used to stochastically propagate damage through the joint. Combined local (e.g., exceedance of a critical damage size) and global (e.g.. flutter instability) failure criteria are finally used to compute the probability of component failure at future times. The applicability and the partial validation of the proposed methodology are then briefly discussed by analyzing the debonding propagation, along a pre-defined adhesive interface, in a simply supported laminated composite beam with solid rectangular cross section, subjected to a concentrated load applied at mid-span. A specially developed Eliler-Bernoulli beam finite element with interlaminar slip along the damageable interface is used in combination with a cohesive zone model to study the fatigue-induced degradation in the adhesive material. The preliminary numerical results presented are promising for the future validation of the methodology.« less

  3. The development of pyro shock test requirements for Viking Lander Capsule components

    NASA Technical Reports Server (NTRS)

    Barrett, S.

    1975-01-01

    The procedure used to derive component-level pyro shock specifications for the Viking Lander Capsule (VLC) is described. Effects of shock path distance and mechanical joints between the device and the point at which the environment is to be estimated are accounted for in the method. The validity of the prediction technique was verified by a series of shock tests on a full-scale structural model of the lander body.

  4. Lamb Wave Polarization Techniques for Structural Damage Localization and Quantification

    DTIC Science & Technology

    2011-11-01

    11  Figure 11. Images showing (a) fatigued aluminum dog bone specimen with 53-mm crack and (b) 3-D SLDV test...Abaqus* and a 3-D model of a plate girder. Experimental measurements using piezoelectric ( PZT ) sensors were located on the web in pulse-echo mode, and...analyzed mode conversion of T- joint with collocated PZT sensors before and after the stiffener using a 2-D simulation under plane strain assumptions

  5. A Clinically Realistic Large Animal Model of Intra-Articular Fracture

    DTIC Science & Technology

    2012-10-01

    articular bone intact. The distal impact face is anchored to the talus using three “tripod” pins, for direct (i.e., no soft tissue intervention) delivery of...pilon) fractures. In this technique, the porcine hock joint (human ankle analogue) is subjected to an injurious transarticular compressive force pulse...fracture, to create fractures morphologically similar to human ankle anterior malleolar fractures. This cut was made on the anterior distal tibial cortex

  6. The key kinematic determinants of undulatory underwater swimming at maximal velocity.

    PubMed

    Connaboy, Chris; Naemi, Roozbeh; Brown, Susan; Psycharakis, Stelios; McCabe, Carla; Coleman, Simon; Sanders, Ross

    2016-01-01

    The optimisation of undulatory underwater swimming is highly important in competitive swimming performance. Nineteen kinematic variables were identified from previous research undertaken to assess undulatory underwater swimming performance. The purpose of the present study was to determine which kinematic variables were key to the production of maximal undulatory underwater swimming velocity. Kinematic data at maximal undulatory underwater swimming velocity were collected from 17 skilled swimmers. A series of separate backward-elimination analysis of covariance models was produced with cycle frequency and cycle length as dependent variables (DVs) and participant as a fixed factor, as including cycle frequency and cycle length would explain 100% of the maximal swimming velocity variance. The covariates identified in the cycle-frequency and cycle-length models were used to form the saturated model for maximal swimming velocity. The final parsimonious model identified three covariates (maximal knee joint angular velocity, maximal ankle angular velocity and knee range of movement) as determinants of the variance in maximal swimming velocity (adjusted-r2 = 0.929). However, when participant was removed as a fixed factor there was a large reduction in explained variance (adjusted r2 = 0.397) and only maximal knee joint angular velocity continued to contribute significantly, highlighting its importance to the production of maximal swimming velocity. The reduction in explained variance suggests an emphasis on inter-individual differences in undulatory underwater swimming technique and/or anthropometry. Future research should examine the efficacy of other anthropometric, kinematic and coordination variables to better understand the production of maximal swimming velocity and consider the importance of individual undulatory underwater swimming techniques when interpreting the data.

  7. A Goniometry Paradigm Shift to Measure Burn Scar Contracture in Burn Patients

    DTIC Science & Technology

    2017-10-01

    test more extensively a recently designed Revised Goniometry (RG) method and compare it to Standard Goniometry (SG)used to measure burn scar...joint angle measurements willbe found between SG techniques compared to RG techniques which incorporate CKM and CFU principles. Specific Aim 1: To... compare the average reduction in joint range of motion measured with the standard GM measurements to a newly conceived set of revised GM measurements in

  8. Direct measurement of group delay with joint time-frequency analysis of a white-light spectral interferogram.

    PubMed

    Deng, Yuqiang; Yang, Weijian; Zhou, Chun; Wang, Xi; Tao, Jun; Kong, Weipeng; Zhang, Zhigang

    2008-12-01

    We propose and demonstrate an analysis method to directly extract the group delay rather than the phase from the white-light spectral interferogram. By the joint time-frequency analysis technique, group delay is directly read from the ridge of wavelet transform, and group-delay dispersion is easily obtained by additional differentiation. The technique shows reasonable potential for the characterization of ultra-broadband chirped mirrors.

  9. Ultrasonic velocity testing of steel pipeline welded joints

    NASA Astrophysics Data System (ADS)

    Carreón, Hector

    2017-04-01

    In general the ultrasonic techniques have been used to determine the mechanical properties of materials on based of their relationship with metallurgical characteristics. In this research work, the relationship between ultrasonic velocity and phased array and the microstructure of steel pipeline welded joints is investigated. Measurements of ultrasonic wave velocity were made as a function of the location across the weld. Hardness measurements were performated in an attempt to correlate with ultrasonic response. In addition, the coarse and dendritic grain structure of the weld material is extreme and unpredictably anisotropic. Thus, due to the acoustic anisotropy of the crystal itself weld material of studied joints is anisotropic, too. Such structure is no longer direction-independent to the ultrasonic wave propagation; therefore, the ultrasonic beam deflects and redirects and the wave front becomes distorted. Thus, the use of conventional ultrasonic testing techniques using fixed beam angles is very limited and the application of conventional ultrasonic phased array techniques becomes desirable.

  10. A methodology to accurately quantify patellofemoral cartilage contact kinematics by combining 3D image shape registration and cine-PC MRI velocity data.

    PubMed

    Borotikar, Bhushan S; Sipprell, William H; Wible, Emily E; Sheehan, Frances T

    2012-04-05

    Patellofemoral osteoarthritis and its potential precursor patellofemoral pain syndrome (PFPS) are common, costly, and debilitating diseases. PFPS has been shown to be associated with altered patellofemoral joint mechanics; however, an actual variation in joint contact stresses has not been established due to challenges in accurately quantifying in vivo contact kinematics (area and location). This study developed and validated a method for tracking dynamic, in vivo cartilage contact kinematics by combining three magnetic resonance imaging (MRI) techniques, cine-phase contrast (CPC), multi-plane cine (MPC), and 3D high-resolution static imaging. CPC and MPC data were acquired from 12 healthy volunteers while they actively extended/flexed their knee within the MRI scanner. Since no gold standard exists for the quantification of in vivo dynamic cartilage contact kinematics, the accuracy of tracking a single point (patellar origin relative to the femur) represented the accuracy of tracking the kinematics of an entire surface. The accuracy was determined by the average absolute error between the PF kinematics derived through registration of MPC images to a static model and those derived through integration of the CPC velocity data. The accuracy ranged from 0.47 mm to 0.77 mm for the patella and femur and from 0.68 mm to 0.86 mm for the patellofemoral joint. For purely quantifying joint kinematics, CPC remains an analytically simpler and more accurate (accuracy <0.33 mm) technique. However, for application requiring the tracking of an entire surface, such as quantifying cartilage contact kinematics, this combined imaging approach produces accurate results with minimal operator intervention. Published by Elsevier Ltd.

  11. Differences in joint morphology between the knee and ankle affect the repair of osteochondral defects in a rabbit model.

    PubMed

    Makitsubo, Manami; Adachi, Nobuo; Nakasa, Tomoyuki; Kato, Tomohiro; Shimizu, Ryo; Ochi, Mitsuo

    2016-10-04

    Although differences in the results of the bone marrow stimulation technique between the knee and ankle have been reported, a detailed mechanism for those differences has not been clarified. The purpose of this study was to examine whether morphological differences between the knee and ankle joint affect the results of drilling as treatment for osteochondral defects in a rabbit model. Osteochondral defects were created at the knee and ankle joint in the rabbit. In the knee, osteochondral defects were created at the medial femoral condyle (MFC) and patellar groove (PG). At the ankle, defects were created in the talus at either a covered or uncovered area by the tibial plafond. After creating the osteochondral defect, drilling was performed. At 4, 8, and 12 weeks after surgery, repair of the osteochondral defects were evaluated histologically. The proliferation of rabbit chondrocytes and proteoglycan release of cartilage tissue in response to IL-1β were analyzed in vitro in both joints. At 8 weeks after surgery, hyaline cartilage repair was observed in defects at the covered area of the talus and the MFC. At 12 weeks, hyaline cartilage with a normal thickness was observed for the defect at the covered area of the talus, but not for the defect at the MFC. At 12 weeks, subchondral bone formation progressed and a normal contour of subchondral bone was observed on CT in the defect at the covered area of the talus. No significant differences in chondrocyte proliferation rate and proteoglycan release were detected between the knee and ankle in vitro. Our results demonstrate that the covered areas of the talus show early and sufficient osteochondral repair compared to that of the knee and the uncovered areas of the talus. These results suggest that the congruent joint shows better subchondral repair prior to cartilage repair compared to that of the incongruent joint.

  12. An anatomical study comparing two surgical approaches for isolated talonavicular arthrodesis.

    PubMed

    Higgs, Zoe; Jamal, Bilal; Fogg, Quentin A; Kumar, C Senthil

    2014-10-01

    Two operative approaches are commonly used for isolated talonavicular arthrodesis: the medial and the dorsal approach. It is recognized that access to the lateral aspect of the talonavicular joint can be limited when using the medial approach, and it is our experience that using the dorsal approach addresses this issue. We performed an anatomical study using cadaver specimens, to compare the amount of articular surface that can be accessed by each operative approach. Medial and dorsal approaches to the talonavicular joint were performed on each of 11 cadaveric specimens (10 fresh frozen, 1 embalmed). Distraction of the joint was performed as used intraoperatively and the accessible area of articular surfaces was marked for each of the 2 approaches using a previously reported technique. Disarticulation was performed and the marked surface area was quantified using an immersion digital microscribe, allowing a 3-dimensional virtual model of the articular surfaces to be assessed. The median percentage of total accessible talonavicular articular surface area for the medial and dorsal approaches was 71% and 92%, respectively (Wilcoxon signed-rank test, P < .001). This study provides quantifiable measurements of the articular surface accessible by the medial and dorsal approaches to the talonavicular joint. These data support for the use of the dorsal approach for talonavicular arthrodesis, particularly in cases where access to the lateral half of the joint is necessary. © The Author(s) 2014.

  13. Osteochondral lesions of the ankle joint in professional soccer players: treatment with autologous matrix-induced chondrogenesis.

    PubMed

    Valderrabano, Victor; Barg, Alexej; Alattar, Abdulhameed; Wiewiorski, Martin

    2014-12-01

    Acute and recurrent ankle sprains and other trauma to the ankle joint are common injuries in soccer and can be accompanied by or result in osteochondral lesions of the ankle joint, majorly of the talus. Conservative treatment frequently fails. Several operative treatment techniques exist; however, the choice of the right procedure is difficult due to lack of literature with a high level of evidence. We present our treatment method for acute and chronic ankle osteochondral lesions with cystic formation approached by a new surgical technique combining bone plasty and a collagen matrix (autologous matrix-induced chondrogenesis). Therapeutic, Level IV: Case series. © 2014 The Author(s).

  14. Experimental study of cyclic creep and high-cycle fatigue of welded joints of St3 steel by the DIC technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kibitkin, Vladimir V., E-mail: vvk@ispms.tsc.ru; Solodushkin, Andrey I., E-mail: s.ai@sibmail.com; Pleshanov, Vasily S., E-mail: vsp@ispms.tsc.ru

    In the paper the mechanisms of plastic deformation and fracture of welded joints of steel St3 were investigated at high-cycle fatigue and cyclic creep by the digital image correlation (DIC) technique. The evolution of strain rate is studied for the following regions: base metal, HAZ, and fusion zone. This strain rate evolution can be considered as a mechanical response of material. Three stages of deformation evolution are shown: deformation hardening (I), fatigue crack initiation (II), and the last stage is related to main crack (III). Two criteria are offered to evaluate the current mechanical state of welded joints.

  15. An equivalent viscoelastic model for rock mass with parallel joints

    NASA Astrophysics Data System (ADS)

    Li, Jianchun; Ma, Guowei; Zhao, Jian

    2010-03-01

    An equivalent viscoelastic medium model is proposed for rock mass with parallel joints. A concept of "virtual wave source (VWS)" is proposed to take into account the wave reflections between the joints. The equivalent model can be effectively applied to analyze longitudinal wave propagation through discontinuous media with parallel joints. Parameters in the equivalent viscoelastic model are derived analytically based on longitudinal wave propagation across a single rock joint. The proposed model is then verified by applying identical incident waves to the discontinuous and equivalent viscoelastic media at one end to compare the output waves at the other end. When the wavelength of the incident wave is sufficiently long compared to the joint spacing, the effect of the VWS on wave propagation in rock mass is prominent. The results from the equivalent viscoelastic medium model are very similar to those determined from the displacement discontinuity method. Frequency dependence and joint spacing effect on the equivalent viscoelastic model and the VWS method are discussed.

  16. Investigation of 2‐stage meta‐analysis methods for joint longitudinal and time‐to‐event data through simulation and real data application

    PubMed Central

    Tudur Smith, Catrin; Gueyffier, François; Kolamunnage‐Dona, Ruwanthi

    2017-01-01

    Background Joint modelling of longitudinal and time‐to‐event data is often preferred over separate longitudinal or time‐to‐event analyses as it can account for study dropout, error in longitudinally measured covariates, and correlation between longitudinal and time‐to‐event outcomes. The joint modelling literature focuses mainly on the analysis of single studies with no methods currently available for the meta‐analysis of joint model estimates from multiple studies. Methods We propose a 2‐stage method for meta‐analysis of joint model estimates. These methods are applied to the INDANA dataset to combine joint model estimates of systolic blood pressure with time to death, time to myocardial infarction, and time to stroke. Results are compared to meta‐analyses of separate longitudinal or time‐to‐event models. A simulation study is conducted to contrast separate versus joint analyses over a range of scenarios. Results Using the real dataset, similar results were obtained by using the separate and joint analyses. However, the simulation study indicated a benefit of use of joint rather than separate methods in a meta‐analytic setting where association exists between the longitudinal and time‐to‐event outcomes. Conclusions Where evidence of association between longitudinal and time‐to‐event outcomes exists, results from joint models over standalone analyses should be pooled in 2‐stage meta‐analyses. PMID:29250814

  17. Technique for joining metal tubing

    NASA Technical Reports Server (NTRS)

    Wright, H. W.

    1976-01-01

    Uniform wall thickness and uninterrupted heat transfer is achieved by using shaped metal insert as wall material for joint. Insert acts as support during brazing, after which excess material is ground away to bring joint to original tubing size.

  18. Implementation of a gait cycle loading into healthy and meniscectomised knee joint models with fibril-reinforced articular cartilage.

    PubMed

    Mononen, Mika E; Jurvelin, Jukka S; Korhonen, Rami K

    2015-01-01

    Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.

  19. A complexity science-based framework for global joint operations analysis to support force projection: LDRD Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawton, Craig R.

    2015-01-01

    The military is undergoing a significant transformation as it modernizes for the information age and adapts to address an emerging asymmetric threat beyond traditional cold war era adversaries. Techniques such as traditional large-scale, joint services war gaming analysis are no longer adequate to support program evaluation activities and mission planning analysis at the enterprise level because the operating environment is evolving too quickly. New analytical capabilities are necessary to address modernization of the Department of Defense (DoD) enterprise. This presents significant opportunity to Sandia in supporting the nation at this transformational enterprise scale. Although Sandia has significant experience with engineeringmore » system of systems (SoS) and Complex Adaptive System of Systems (CASoS), significant fundamental research is required to develop modeling, simulation and analysis capabilities at the enterprise scale. This report documents an enterprise modeling framework which will enable senior level decision makers to better understand their enterprise and required future investments.« less

  20. Joint distraction and movement for repair of articular cartilage in a rabbit model with subsequent weight-bearing.

    PubMed

    Nishino, T; Chang, F; Ishii, T; Yanai, T; Mishima, H; Ochiai, N

    2010-07-01

    We have previously shown that joint distraction and movement with a hinged external fixation device for 12 weeks was useful for repairing a large articular cartilage defect in a rabbit model. We have now investigated the results after six months and one year. The device was applied to 16 rabbits who underwent resection of the articular cartilage and subchondral bone from the entire tibial plateau. In group A (nine rabbits) the device was applied for six months. In group B (seven rabbits) it was in place for six months, after which it was removed and the animals were allowed to move freely for an additional six months. The cartilage remained sound in all rabbits. The areas of type II collagen-positive staining and repaired soft tissue were larger in group B than in group A. These findings provide evidence of long-term persistence of repaired cartilage with this technique and that weight-bearing has a positive effect on the quality of the cartilage.

  1. Qualitative and quantitative descriptions of glenohumeral motion.

    PubMed

    Hill, A M; Bull, A M J; Wallace, A L; Johnson, G R

    2008-02-01

    Joint modelling plays an important role in qualitative and quantitative descriptions of both normal and abnormal joints, as well as predicting outcomes of alterations to joints in orthopaedic practice and research. Contemporary efforts in modelling have focussed upon the major articulations of the lower limb. Well-constrained arthrokinematics can form the basis of manageable kinetic and dynamic mathematical predictions. In order to contain computation of shoulder complex modelling, glenohumeral joint representations in both limited and complete shoulder girdle models have undergone a generic simplification. As such, glenohumeral joint models are often based upon kinematic descriptions of inadequate degrees of freedom (DOF) for clinical purposes and applications. Qualitative descriptions of glenohumeral motion range from the parody of a hinge joint to the complex realism of a spatial joint. In developing a model, a clear idea of intention is required in order to achieve a required application. Clinical applicability of a model requires both descriptive and predictive output potentials, and as such, a high level of validation is required. Without sufficient appreciation of the clinical intention of the arthrokinematic foundation to a model, error is all too easily introduced. Mathematical description of joint motion serves to quantify all relevant clinical parameters. Commonly, both the Euler angle and helical (screw) axis methods have been applied to the glenohumeral joint, although concordance between these methods and classical anatomical appreciation of joint motion is limited, resulting in miscommunication between clinician and engineer. Compounding these inconsistencies in motion quantification is gimbal lock and sequence dependency.

  2. Low Activation Joining of SiC/SiC Composites for Fusion Applications: Modeling Miniature Torsion Tests with Elastic and Elastic-Plastic Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henager, Charles H.; Nguyen, Ba Nghiep; Kurtz, Richard J.

    2015-06-30

    The international fusion community designed miniature torsion specimens for joint testing and irradiation in test reactors with limited irradiation volumes since SiC and SiC-composites used in fission or fusion environments require joining methods for assembling systems. Torsion specimens fail out-of-plane when joints are strong and when elastic moduli are comparable to SiC, which causes difficulties in determining shear strengths for many joints or for comparing unirradiated and irradiated joints. A finite element damage model was developed to treat elastic joints such as SiC/Ti3SiC2+SiC and elastic-plastic joints such as SiC/epoxy and steel/epoxy. The model uses constitutive shear data and is validatedmore » using epoxy joint data. The elastic model indicates fracture is likely to occur within the joined pieces to cause out-of-plane failures for miniature torsion specimens when a certain modulus and strength ratio between the joint material and the joined material exists. Lower modulus epoxy joints always fail in plane and provide good model validation.« less

  3. Maximum voluntary joint torque as a function of joint angle and angular velocity: model development and application to the lower limb.

    PubMed

    Anderson, Dennis E; Madigan, Michael L; Nussbaum, Maury A

    2007-01-01

    Measurements of human strength can be important during analyses of physical activities. Such measurements have often taken the form of the maximum voluntary torque at a single joint angle and angular velocity. However, the available strength varies substantially with joint position and velocity. When examining dynamic activities, strength measurements should account for these variations. A model is presented of maximum voluntary joint torque as a function of joint angle and angular velocity. The model is based on well-known physiological relationships between muscle force and length and between muscle force and velocity and was tested by fitting it to maximum voluntary joint torque data from six different exertions in the lower limb. Isometric, concentric and eccentric maximum voluntary contractions were collected during hip extension, hip flexion, knee extension, knee flexion, ankle plantar flexion and dorsiflexion. Model parameters are reported for each of these exertion directions by gender and age group. This model provides an efficient method by which strength variations with joint angle and angular velocity may be incorporated into comparisons between joint torques calculated by inverse dynamics and the maximum available joint torques.

  4. Three dimensional measurement of minimum joint space width in the knee from stereo radiographs using statistical shape models.

    PubMed

    van IJsseldijk, E A; Valstar, E R; Stoel, B C; Nelissen, R G H H; Baka, N; Van't Klooster, R; Kaptein, B L

    2016-08-01

    An important measure for the diagnosis and monitoring of knee osteoarthritis is the minimum joint space width (mJSW). This requires accurate alignment of the x-ray beam with the tibial plateau, which may not be accomplished in practice. We investigate the feasibility of a new mJSW measurement method from stereo radiographs using 3D statistical shape models (SSM) and evaluate its sensitivity to changes in the mJSW and its robustness to variations in patient positioning and bone geometry. A validation study was performed using five cadaver specimens. The actual mJSW was varied and images were acquired with variation in the cadaver positioning. For comparison purposes, the mJSW was also assessed from plain radiographs. To study the influence of SSM model accuracy, the 3D mJSW measurement was repeated with models from the actual bones, obtained from CT scans. The SSM-based measurement method was more robust (consistent output for a wide range of input data/consistent output under varying measurement circumstances) than the conventional 2D method, showing that the 3D reconstruction indeed reduces the influence of patient positioning. However, the SSM-based method showed comparable sensitivity to changes in the mJSW with respect to the conventional method. The CT-based measurement was more accurate than the SSM-based measurement (smallest detectable differences 0.55 mm versus 0. 82 mm, respectively). The proposed measurement method is not a substitute for the conventional 2D measurement due to limitations in the SSM model accuracy. However, further improvement of the model accuracy and optimisation technique can be obtained. Combined with the promising options for applications using quantitative information on bone morphology, SSM based 3D reconstructions of natural knees are attractive for further development.Cite this article: E. A. van IJsseldijk, E. R. Valstar, B. C. Stoel, R. G. H. H. Nelissen, N. Baka, R. van't Klooster, B. L. Kaptein. Three dimensional measurement of minimum joint space width in the knee from stereo radiographs using statistical shape models. Bone Joint Res 2016;320-327. DOI: 10.1302/2046-3758.58.2000626. © 2016 van IJsseldijk et al.

  5. Climatic Models Ensemble-based Mid-21st Century Runoff Projections: A Bayesian Framework

    NASA Astrophysics Data System (ADS)

    Achieng, K. O.; Zhu, J.

    2017-12-01

    There are a number of North American Regional Climate Change Assessment Program (NARCCAP) climatic models that have been used to project surface runoff in the mid-21st century. Statistical model selection techniques are often used to select the model that best fits data. However, model selection techniques often lead to different conclusions. In this study, ten models are averaged in Bayesian paradigm to project runoff. Bayesian Model Averaging (BMA) is used to project and identify effect of model uncertainty on future runoff projections. Baseflow separation - a two-digital filter which is also called Eckhardt filter - is used to separate USGS streamflow (total runoff) into two components: baseflow and surface runoff. We use this surface runoff as the a priori runoff when conducting BMA of runoff simulated from the ten RCM models. The primary objective of this study is to evaluate how well RCM multi-model ensembles simulate surface runoff, in a Bayesian framework. Specifically, we investigate and discuss the following questions: How well do ten RCM models ensemble jointly simulate surface runoff by averaging over all the models using BMA, given a priori surface runoff? What are the effects of model uncertainty on surface runoff simulation?

  6. Studies on Creep Deformation and Rupture Behavior of 316LN SS Multi-Pass Weld Joints Fabricated with Two Different Electrode Sizes

    NASA Astrophysics Data System (ADS)

    Vijayanand, V. D.; Kumar, J. Ganesh; Parida, P. K.; Ganesan, V.; Laha, K.

    2017-02-01

    Effect of electrode size on creep deformation and rupture behavior has been assessed by carrying out creep tests at 923 K (650 °C) over the stress range 140 to 225 MPa on 316LN stainless steel weld joints fabricated employing 2.5 and 4 mm diameter electrodes. The multi-pass welding technique not only changes the morphology of delta ferrite from vermicular to globular in the previous weld bead region near to the weld bead interface, but also subjects the region to thermo-mechanical heat treatment to generate appreciable strength gradient. Electron backscatter diffraction analysis revealed significant localized strain gradients in regions adjoining the weld pass interface for the joint fabricated with large electrode size. Larger electrode diameter joint exhibited higher creep rupture strength than the smaller diameter electrode joint. However, both the joints had lower creep rupture strength than the base metal. Failure in the joints was associated with microstructural instability in the fusion zone, and the vermicular delta ferrite zone was more prone to creep cavitation. Larger electrode diameter joint was found to be more resistant to failure caused by creep cavitation than the smaller diameter electrode joint. This has been attributed to the larger strength gradient between the beads and significant separation between the cavity prone vermicular delta ferrite zones which hindered the cavity growth. Close proximity of cavitated zones in smaller electrode joint facilitated their faster coalescence leading to more reduction in creep rupture strength. Failure location in the joints was found to depend on the electrode size and applied stress. The change in failure location has been assessed on performing finite element analysis of stress distribution across the joint on incorporating tensile and creep strengths of different constituents of joints, estimated by ball indentation and impression creep testing techniques.

  7. A Single-Lap Joint Adhesive Bonding Optimization Method Using Gradient and Genetic Algorithms

    NASA Technical Reports Server (NTRS)

    Smeltzer, Stanley S., III; Finckenor, Jeffrey L.

    1999-01-01

    A natural process for any engineer, scientist, educator, etc. is to seek the most efficient method for accomplishing a given task. In the case of structural design, an area that has a significant impact on the structural efficiency is joint design. Unless the structure is machined from a solid block of material, the individual components which compose the overall structure must be joined together. The method for joining a structure varies depending on the applied loads, material, assembly and disassembly requirements, service life, environment, etc. Using both metallic and fiber reinforced plastic materials limits the user to two methods or a combination of these methods for joining the components into one structure. The first is mechanical fastening and the second is adhesive bonding. Mechanical fastening is by far the most popular joining technique; however, in terms of structural efficiency, adhesive bonding provides a superior joint since the load is distributed uniformly across the joint. The purpose of this paper is to develop a method for optimizing single-lap joint adhesive bonded structures using both gradient and genetic algorithms and comparing the solution process for each method. The goal of the single-lap joint optimization is to find the most efficient structure that meets the imposed requirements while still remaining as lightweight, economical, and reliable as possible. For the single-lap joint, an optimum joint is determined by minimizing the weight of the overall joint based on constraints from adhesive strengths as well as empirically derived rules. The analytical solution of the sin-le-lap joint is determined using the classical Goland-Reissner technique for case 2 type adhesive joints. Joint weight minimization is achieved using a commercially available routine, Design Optimization Tool (DOT), for the gradient solution while an author developed method is used for the genetic algorithm solution. Results illustrate the critical design variables as a function of adhesive properties and convergences of different joints based on the two optimization methods.

  8. Active and passive electrical and seismic time-lapse monitoring of earthen embankments

    NASA Astrophysics Data System (ADS)

    Rittgers, Justin Bradley

    In this dissertation, I present research involving the application of active and passive geophysical data collection, data assimilation, and inverse modeling for the purpose of earthen embankment infrastructure assessment. Throughout the dissertation, I identify several data characteristics, and several challenges intrinsic to characterization and imaging of earthen embankments and anomalous seepage phenomena, from both a static and time-lapse geophysical monitoring perspective. I begin with the presentation of a field study conducted on a seeping earthen dam, involving static and independent inversions of active tomography data sets, and self-potential modeling of fluid flow within a confined aquifer. Additionally, I present results of active and passive time-lapse geophysical monitoring conducted during two meso-scale laboratory experiments involving the failure and self-healing of embankment filter materials via induced vertical cracking. Identified data signatures and trends, as well as 4D inversion results, are discussed as an underlying motivation for conducting subsequent research. Next, I present a new 4D acoustic emissions source localization algorithm that is applied to passive seismic monitoring data collected during a full-scale embankment failure test. Acoustic emissions localization results are then used to help spatially constrain 4D inversion of collocated self-potential monitoring data. I then turn to time-lapse joint inversion of active tomographic data sets applied to the characterization and monitoring of earthen embankments. Here, I develop a new technique for applying spatiotemporally varying structural joint inversion constraints. The new technique, referred to as Automatic Joint Constraints (AJC), is first demonstrated on a synthetic 2D joint model space, and is then applied to real geophysical monitoring data sets collected during a full-scale earthen embankment piping-failure test. Finally, I discuss some non-technical issues related to earthen embankment failures from a Science, Technology, Engineering, and Policy (STEP) perspective. Here, I discuss how the proclaimed scientific expertise and shifting of responsibility (Responsibilization) by governing entities tasked with operating and maintaining water storage and conveyance infrastructure throughout the United States tends to create barriers for 1) public voice and participation in relevant technical activities and outcomes, 2) meaningful discussions with the public and media during crisis communication, and 3) public perception of risk and the associated resilience of downhill communities.

  9. Partially linear mixed-effects joint models for skewed and missing longitudinal competing risks outcomes.

    PubMed

    Lu, Tao; Lu, Minggen; Wang, Min; Zhang, Jun; Dong, Guang-Hui; Xu, Yong

    2017-12-18

    Longitudinal competing risks data frequently arise in clinical studies. Skewness and missingness are commonly observed for these data in practice. However, most joint models do not account for these data features. In this article, we propose partially linear mixed-effects joint models to analyze skew longitudinal competing risks data with missingness. In particular, to account for skewness, we replace the commonly assumed symmetric distributions by asymmetric distribution for model errors. To deal with missingness, we employ an informative missing data model. The joint models that couple the partially linear mixed-effects model for the longitudinal process, the cause-specific proportional hazard model for competing risks process and missing data process are developed. To estimate the parameters in the joint models, we propose a fully Bayesian approach based on the joint likelihood. To illustrate the proposed model and method, we implement them to an AIDS clinical study. Some interesting findings are reported. We also conduct simulation studies to validate the proposed method.

  10. Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods.

    PubMed

    Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J Sunil

    2014-08-01

    We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called "Patient Recursive Survival Peeling" is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called "combined" cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication.

  11. Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods

    PubMed Central

    Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J. Sunil

    2015-01-01

    We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called “Patient Recursive Survival Peeling” is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called “combined” cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication. PMID:26997922

  12. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    PubMed

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  13. Effect of Nd:YAG laser beam welding on weld morphology and mechanical properties of Ti-6Al-4V butt joints and T-joints

    NASA Astrophysics Data System (ADS)

    Kashaev, Nikolai; Ventzke, Volker; Fomichev, Vadim; Fomin, Fedor; Riekehr, Stefan

    2016-11-01

    A Nd:YAG single-sided laser beam welding process study for Ti-6Al-4V butt joints and T-joints was performed to investigate joining techniques with regard to the process-weld morphology relationship. An alloy compatible filler wire was used to avoid underfills and undercuts. The quality of the butt joints and T-joints was characterized in terms of weld morphology, microstructure and mechanical properties. Joints with regular shapes, without visible cracks, pores, and geometrical defects were achieved. Tensile tests revealed high joint integrity in terms of strength and ductility for both the butt joint and T-joint geometries. Both the butt joints and T-joints showed base material levels of strength. The mechanical performance of T-joints was also investigated using pull-out tests. The performance of the T-joints in such tests was sensitive to the shape and morphology of the welds. Fracture always occurred in the weld without any plastic deformation in the base material outside the weld.

  14. Case Report: The casting motion to mobilize stiffness technique for rehabilitation after a crush and degloving injury of the hand.

    PubMed

    Midgley, Robyn

    2016-01-01

    Case report. This case report describes the use of the casting motion to mobilize stiffness (CMMS) technique in the management of a crush and degloving injury of the hand. The patient was unable to attend multiple hand therapy sessions due to geographic constraints. The CMMS technique involved the application of a nonremovable plaster of paris cast that selectively immobilizes proximal joints in an ideal position while constraining distal joints to direct desired motion over a long period. This uses active motion only. Traditional hand therapy techniques or modalities are not used. This treatment approach was beneficial to the patient as a minimum of 2 appointments per month were needed to regain functional hand use. To document the use of the CMMS technique as an effective treatment approach in the management of a crush and degloving injury of the hand. The CMMS technique was applied to the patient's left (nondominant) hand 8 weeks after injury. The technique's aim was to improve the 30° flexion deformity of the left wrist and flexion contractures of the index, middle, and ring fingers with a total active motion of 0°. Orthotic devices and traditional therapy were applied once joint stiffness was resolved, and a normal pattern of motion was reinstated. At 6 months, substantial improvement was noted in wrist as well as metacarpophalangeal and interphalangeal joints. Total active motion exceeded 170° in all fingers excellent functional outcome resulted as measured with the upper limb functional index short form-10. The upper limb functional index increased from 0% to 55% of preinjury status (or capacity) over the 18 months of therapy. Brief immobilization through casting causes certain functional losses, but these are temporary and reversible. Finger stiffness, edema, and tissue fibrosis were successfully managed with the CMMS technique without the need for attendance at multiple hand therapy sessions. Level V. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  15. Development of brazing process for W-EUROFER joints using Cu-based fillers

    NASA Astrophysics Data System (ADS)

    de Prado, J.; Sánchez, M.; Ureña, A.

    2016-02-01

    A successful joint between W and EUROFER using high temperature brazing technique has been achieved for structural application in future fusion power plants. Cu-based powder alloy mixed with a polymeric binder has been used as filler. Microstructural analysis of the joints revealed that the joint consisted mainly of primary phases and acicular structures in a Cu matrix. Interaction between EUROFER and filler took place at the interface giving rise to several Cu-Ti-Fe rich layers. A loss of hardness at the EUROFER substrate close to the joint due to a diffusion phenomenon during brazing cycle was measured; however, the joints had an adequate shear strength value.

  16. Complications with the use of Artelon in thumb CMC joint arthritis.

    PubMed

    Clarke, Sylvan; Hagberg, William; Kaufmann, Robert A; Grand, Aaron; Wollstein, Ronit

    2011-09-01

    Complications with the use of the Artelon spacer in thumb carpometacarpal (CMC) joint arthritis include inflammation, osteolysis, and persistent pain. We evaluated our short-term results and complications. A retrospective review of 29 patients was performed. Pre- and postoperative radiographs, operative techniques, complications, and subsequent surgeries were analyzed. Pearson's and chi-squared testing was used to identify associations between complications and surgical technique or preoperative radiographic criteria. The average age was age 51 ± 7.7 (34-66), average follow-up was 8 months (1-26). Twelve patients sustained complications. Nine patients displayed postoperative osteolysis. Four patients underwent conversion to CMC suspensionplasty due to persistent pain. The rate of revision surgery and radiographic postoperative osteolysis were not significantly associated with preoperative arthritis grade, metacarpal subluxation, or surgical techniques: fixation method, the bony surface(s) involved in the osteotomy, or spacer modifications. Our study found a significant short-term complication rate following Artelon spacer arthroplasty of the CMC joint. This is higher than previously described. We could not identify any factors that were significantly associated with the complications. It is possible that the inherent instability of the joint or the material of the spacer is involved in implant failure. Further study is necessary to better define the indications for use and specific techniques for the use of the implant.

  17. [Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness].

    PubMed

    Ma, Ryewon; Jung, Dukyoo

    2016-02-01

    This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.

  18. Development of non-destructive examination techniques for CFC-metal joints in annular geometry and their application to the manufacturing of plasma-facing components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Pietro, E.; Visca, E.; Orsini, A.

    1995-12-31

    The design of plasma-facing components for ITER, as for any of the envisaged next-step machines, relies heavily on the use of brazed junctions to couple armour materials to the heat sink and cooling tubes. Moreover, the typical number of brazed components and the envisaged effects of local overheating due to failure in a single brazed junction stress the importance of having a set of NDE techniques developed that can ensure the flawless quality of the joint. The qualification and application of two NDE techniques (ultrasonic and thermographic analysis) for inspection of CFC-to-metal joints is described with particular regard to themore » annular geometry typical of macroblock/monoblock solutions for divertor high-heat-flux components. The results of the eddy current inspection are not reported. The development has been focused specifically on the joint between carbon-fiber composite and TZM molybdenum alloy; techniques for the production of reference defect samples have been devised and a set of reference defect samples produced. The comparative results of the NDE inspections are reported and discussed, also on the basis of the destructive examination of the samples. The nature and size of relevant and detectable defects are discussed together with hints for a possible NDE strategy for divertor high-heat-flux components.« less

  19. Efficient finite element modelling for the investigation of the dynamic behaviour of a structure with bolted joints

    NASA Astrophysics Data System (ADS)

    Omar, R.; Rani, M. N. Abdul; Yunus, M. A.; Mirza, W. I. I. Wan Iskandar; Zin, M. S. Mohd

    2018-04-01

    A simple structure with bolted joints consists of the structural components, bolts and nuts. There are several methods to model the structures with bolted joints, however there is no reliable, efficient and economic modelling methods that can accurately predict its dynamics behaviour. Explained in this paper is an investigation that was conducted to obtain an appropriate modelling method for bolted joints. This was carried out by evaluating four different finite element (FE) models of the assembled plates and bolts namely the solid plates-bolts model, plates without bolt model, hybrid plates-bolts model and simplified plates-bolts model. FE modal analysis was conducted for all four initial FE models of the bolted joints. Results of the FE modal analysis were compared with the experimental modal analysis (EMA) results. EMA was performed to extract the natural frequencies and mode shapes of the test physical structure with bolted joints. Evaluation was made by comparing the number of nodes, number of elements, elapsed computer processing unit (CPU) time, and the total percentage of errors of each initial FE model when compared with EMA result. The evaluation showed that the simplified plates-bolts model could most accurately predict the dynamic behaviour of the structure with bolted joints. This study proved that the reliable, efficient and economic modelling of bolted joints, mainly the representation of the bolting, has played a crucial element in ensuring the accuracy of the dynamic behaviour prediction.

  20. Dynamic Analyses Including Joints Of Truss Structures

    NASA Technical Reports Server (NTRS)

    Belvin, W. Keith

    1991-01-01

    Method for mathematically modeling joints to assess influences of joints on dynamic response of truss structures developed in study. Only structures with low-frequency oscillations considered; only Coulomb friction and viscous damping included in analysis. Focus of effort to obtain finite-element mathematical models of joints exhibiting load-vs.-deflection behavior similar to measured load-vs.-deflection behavior of real joints. Experiments performed to determine stiffness and damping nonlinearities typical of joint hardware. Algorithm for computing coefficients of analytical joint models based on test data developed to enable study of linear and nonlinear effects of joints on global structural response. Besides intended application to large space structures, applications in nonaerospace community include ground-based antennas and earthquake-resistant steel-framed buildings.

  1. Analytical and Experimental Assessment of Seismic Vulnerability of Beam-Column Joints without Transverse Reinforcement in Concrete Buildings

    NASA Astrophysics Data System (ADS)

    Hassan, Wael Mohammed

    Beam-column joints in concrete buildings are key components to ensure structural integrity of building performance under seismic loading. Earthquake reconnaissance has reported the substantial damage that can result from inadequate beam-column joints. In some cases, failure of older-type corner joints appears to have led to building collapse. Since the 1960s, many advances have been made to improve seismic performance of building components, including beam-column joints. New design and detailing approaches are expected to produce new construction that will perform satisfactorily during strong earthquake shaking. Much less attention has been focused on beam-column joints of older construction that may be seismically vulnerable. Concrete buildings constructed prior to developing details for ductility in the 1970s normally lack joint transverse reinforcement. The available literature concerning the performance of such joints is relatively limited, but concerns about performance exist. The current study aimed to improve understanding and assessment of seismic performance of unconfined exterior and corner beam-column joints in existing buildings. An extensive literature survey was performed, leading to development of a database of about a hundred tests. Study of the data enabled identification of the most important parameters and the effect of each parameter on the seismic performance. The available analytical models and guidelines for strength and deformability assessment of unconfined joints were surveyed and evaluated. In particular, The ASCE 41 existing building document proved to be substantially conservative in joint shear strength estimation. Upon identifying deficiencies in these models, two new joint shear strength models, a bond capacity model, and two axial capacity models designed and tailored specifically for unconfined beam-column joints were developed. The proposed models strongly correlated with previous test results. In the laboratory testing phase of the current study, four full-scale corner beam-column joint subassemblies, with slab included, were designed, built, instrumented, tested, and analyzed. The specimens were tested under unidirectional and bidirectional displacement-controlled quasi-static loading that incorporated varying axial loads that simulated overturning seismic moment effects. The axial loads varied between tension and high compression loads reaching about 50% of the column axial capacity. The test parameters were axial load level, loading history, joint aspect ratio, and beam reinforcement ratio. The test results proved that high axial load increases joint shear strength and decreases the deformability of joints failing in pure shear failure mode without beam yielding. On the contrary, high axial load did not affect the strength of joints failing in shear after significant beam yielding; however, it substantially increased their displacement ductility. Joint aspect ratio proved to be instrumental in deciding joint shear strength; that is the deeper the joint the lower the shear strength. Bidirectional loading reduced the apparent strength of the joint in the uniaxial principal axes. However, circular shear strength interaction is an appropriate approximation to predict the biaxial strength. The developed shear strength models predicted successfully the strength of test specimens. Based on the literature database investigation, the shear and axial capacity models developed and the test results of the current study, an analytical finite element component model based on a proposed joint shear stress-rotation backbone constitutive curve was developed to represent the behavior of unconfined beam-column joints in computer numerical simulations of concrete frame buildings. The proposed finite element model included the effect of axial load, mode of joint failure, joint aspect ratio and axial capacity of joint. The proposed backbone curve along with the developed joint element exhibited high accuracy in simulating the test response of the current test specimens as well as previous test joints. Finally, a parametric study was conducted to assess the axial failure vulnerability of unconfined beam-column joints based on the developed shear and axial capacity models. This parametric study compared the axial failure potential of unconfined beam-column joint with that of shear critical columns to provide a preliminary insight into the axial collapse vulnerability of older-type buildings during intense ground shaking.

  2. Joint Control for Dummies: An Elaboration of Lowenkron's Model of Joint (Stimulus) Control

    ERIC Educational Resources Information Center

    Sidener, David W.

    2006-01-01

    The following paper describes Lowenkron's model of joint (stimulus) control. Joint control is described as a means of accounting for performances, especially generalized performances, for which a history of contingency control does not provide an adequate account. Examples are provided to illustrate instances in which joint control may facilitate…

  3. A cadaveric investigation into the demographic and bony alignment properties associated with osteoarthritis of the patellofemoral joint.

    PubMed

    Weinberg, Douglas S; Tucker, Braden J; Drain, Joseph P; Wang, David M; Gilmore, Allison; Liu, Raymond W

    2016-06-01

    Patellofemoral joint osteoarthritis is common, although circumstances dictating its evolution and pathogenesis remain unclear. Advances in surgical technique have improved the ability to modify long-bone alignment in the coronal, sagittal, and axial planes. However, to our knowledge, there is no significant long-term data available in regard to the relationship between anatomic alignment parameters most amenable to surgical modification and patellofemoral joint osteoarthritis. Five-hundred and seventy-one cadaveric skeletons were obtained from the Hamann-Todd osteological collection. Mechanical lateral distal femoral angle, medial proximal tibial angle, tibial slope, femoral version, tibial torsion, the position of the tibial tubercle relative to the width of the tibial plateau, trochlear depth, and patellar size were measured using validated techniques. A previously published grading system for patellofemoral joint arthritis was used to quantify macroscopic signs of degenerative joint disease. Increasing age (standardized beta 0.532, p<0.001), female gender (standardized beta 0.201, p=0.002), and decreasing mechanical lateral distal femoral angle (standardized beta -0.128, p=0.025) were independent correlates of increased patellofemoral joint osteoarthritis. A relatively more laterally positioned tibial tubercle trended towards predicting patellofemoral joint osteoarthritis (standardized beta 0.080, p=0.089). These findings confirm that patellofemoral joint osteoarthritis is strongly associated with increasing age and female gender. Valgus alignment of the distal femur, a relatively more lateral location of the tibial tubercle, and a shallower trochlear grove appear to have modest effects on the development of patellofemoral joint osteoarthritis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Arthroscopic treatment of acute acromioclavicular joint dislocation by coracoclavicular ligament augmentation.

    PubMed

    Liu, Xudong; Huangfu, Xiaoqiao; Zhao, Jinzhong

    2015-05-01

    Coracoclavicular (CC) ligament augmentation has been a method to treat acromioclavicular (AC) joint dislocation in recent years. The purpose of this paper is to describe our arthroscopic CC ligament augmentation technique in treating type III and V acute AC joint dislocations and to report the early clinical and radiological results. From 2010 to 2011, twelve patients suffering from acute type III or V AC joint dislocations were arthroscopically treated in our department, by CC ligament augmentation after AC joint reduction. The post-operative outcomes were assessed through physical examination, radiographic examination and the Constant-Murley Shoulder Score. All patients post-operatively experienced anatomical reduction in their AC joint dislocation. No intraoperative complications occurred. At a mean follow-up at 24 months (ranging from 18 to 32 months), the mean Constant-Murley Shoulder Score significantly improved from 24.3 pre-operatively to 91.1 post-operatively. No neurovascular complications or secondary degenerative changes of the AC joint were detected in any of the patients. In one case, a second dislocation occurred 1 month post-operation because the patient had had another traumatic injury. This patient accepted a revision operation, but his AC joint eventually fixated into a subluxated position after his second injury. Based on the resultant successful repair in all cases, the arthroscopic CC ligament augmentation method has thus far proven to be a safe and reliable technique for treatment of acute type III or V AC joint dislocation. The arthroscopic CC ligament augmentation with a flip button/polyethylene belt repair is an efficient method to treat acute type III and V AC joint dislocations which should be popularized. IV.

  5. Assessment of NDE Methods to Detect Lack of Fusion in HDPE Butt Fusion Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, Susan L.; Doctor, Steven R.; Cinson, Anthony D.

    2011-07-31

    Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, were conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provided information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test formore » determining joint integrity. A series of butt joints were fabricated in 3408, 12-inch (30.5-cm) IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer diameter (OD) weld beads were removed for microwave evaluation and the pipes ultrasonically re-evaluated. In two of the six pipes, both the outer and inner diameter (ID) weld beads were removed and the pipe joints re-evaluated. Some of the pipes were sectioned and the joints destructively evaluated with the high-speed tensile test and the side-bend test. The fusion parameters, nondestructive and destructive evaluation results have been correlated to validate the effectiveness of what each NDE technology detects and what each does not detect. There was no single NDE method that detected all of the lack-of-fusion flaws but a combination of NDE methods did detect most of the flaws.« less

  6. Computed tomographic anatomy of the equine stifle joint.

    PubMed

    Vekens, Elke Van der; Bergman, Erik H J; Vanderperren, Katrien; Raes, Els V; Puchalski, Sarah M; Bree, Henri J J van; Saunders, Jimmy H

    2011-04-01

    To provide a detailed computed tomography (CT) reference of the anatomically normal equine stifle joint. Sample-16 hind limbs from 8 equine cadavers; no horses had evidence of orthopedic disease of the stifle joints. CT of the stifle joint was performed on 8 hind limbs. In all limbs, CT was also performed after intra-articular injection of 60 mL of contrast material (150 mg of iodine/mL) in the lateral and medial compartments of the femorotibial joint and 80 mL of contrast material in the femoropatellar joint (CT arthrography). Reformatted CT images in the transverse, parasagittal, and dorsal plane were matched with corresponding anatomic slices of the 8 remaining limbs. The femur, tibia, and patella were clearly visible. The patellar ligaments, common origin of the tendinous portions of the long digital extensor muscle and peroneus tertius muscle, collateral ligaments, tendinous portion of the popliteus muscle, and cranial and caudal cruciate ligaments could also be consistently evaluated. The cruciate ligaments and the meniscotibial ligaments could be completely assessed in the arthrogram sequences. Margins of the meniscofemoral ligament and the lateral and medial femoropatellar ligaments were difficult to visualize on the precontrast and postcontrast images. CT and CT arthrography were used to accurately identify and characterize osseous and soft tissue structures of the equine stifle joint. This technique may be of value when results from other diagnostic imaging techniques are inconclusive. The images provided will serve as a CT reference for the equine stifle joint.

  7. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    PubMed Central

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  8. Rocket exhaust effluent modeling for tropospheric air quality and environmental assessments

    NASA Technical Reports Server (NTRS)

    Stephens, J. B.; Stewart, R. B.

    1977-01-01

    The various techniques for diffusion predictions to support air quality predictions and environmental assessments for aerospace applications are discussed in terms of limitations imposed by atmospheric data. This affords an introduction to the rationale behind the selection of the National Aeronautics and Space Administration (NASA)/Marshall Space Flight Center (MSFC) Rocket Exhaust Effluent Diffusion (REED) program. The models utilized in the NASA/MSFC REED program are explained. This program is then evaluated in terms of some results from a joint MSFC/Langley Research Center/Kennedy Space Center Titan Exhaust Effluent Prediction and Monitoring Program.

  9. Tackling missing radiographic progression data: multiple imputation technique compared with inverse probability weights and complete case analysis.

    PubMed

    Descalzo, Miguel Á; Garcia, Virginia Villaverde; González-Alvaro, Isidoro; Carbonell, Jordi; Balsa, Alejandro; Sanmartí, Raimon; Lisbona, Pilar; Hernandez-Barrera, Valentín; Jiménez-Garcia, Rodrigo; Carmona, Loreto

    2013-02-01

    To describe the results of different statistical ways of addressing radiographic outcome affected by missing data--multiple imputation technique, inverse probability weights and complete case analysis--using data from an observational study. A random sample of 96 RA patients was selected for a follow-up study in which radiographs of hands and feet were scored. Radiographic progression was tested by comparing the change in the total Sharp-van der Heijde radiographic score (TSS) and the joint erosion score (JES) from baseline to the end of the second year of follow-up. MI technique, inverse probability weights in weighted estimating equation (WEE) and CC analysis were used to fit a negative binomial regression. Major predictors of radiographic progression were JES and joint space narrowing (JSN) at baseline, together with baseline disease activity measured by DAS28 for TSS and MTX use for JES. Results from CC analysis show larger coefficients and s.e.s compared with MI and weighted techniques. The results from the WEE model were quite in line with those of MI. If it seems plausible that CC or MI analysis may be valid, then MI should be preferred because of its greater efficiency. CC analysis resulted in inefficient estimates or, translated into non-statistical terminology, could guide us into inaccurate results and unwise conclusions. The methods discussed here will contribute to the use of alternative approaches for tackling missing data in observational studies.

  10. Investigation of 2-stage meta-analysis methods for joint longitudinal and time-to-event data through simulation and real data application.

    PubMed

    Sudell, Maria; Tudur Smith, Catrin; Gueyffier, François; Kolamunnage-Dona, Ruwanthi

    2018-04-15

    Joint modelling of longitudinal and time-to-event data is often preferred over separate longitudinal or time-to-event analyses as it can account for study dropout, error in longitudinally measured covariates, and correlation between longitudinal and time-to-event outcomes. The joint modelling literature focuses mainly on the analysis of single studies with no methods currently available for the meta-analysis of joint model estimates from multiple studies. We propose a 2-stage method for meta-analysis of joint model estimates. These methods are applied to the INDANA dataset to combine joint model estimates of systolic blood pressure with time to death, time to myocardial infarction, and time to stroke. Results are compared to meta-analyses of separate longitudinal or time-to-event models. A simulation study is conducted to contrast separate versus joint analyses over a range of scenarios. Using the real dataset, similar results were obtained by using the separate and joint analyses. However, the simulation study indicated a benefit of use of joint rather than separate methods in a meta-analytic setting where association exists between the longitudinal and time-to-event outcomes. Where evidence of association between longitudinal and time-to-event outcomes exists, results from joint models over standalone analyses should be pooled in 2-stage meta-analyses. © 2017 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  11. Low Activation Joining of SiC/SiC Composites for Fusion Applications: Thermomechanical Modeling of Dual-Phase Microstructures and Dissimilar Material Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Ba Nghiep; Henager, Charles H.; Kurtz, Richard J.

    2016-09-30

    Finite element (FE) continuum damage mechanics (CDM) models have been developed to simulate and model dual-phase joints and cracked joints for improved analysis of SiC materials in nuclear environments. This report extends the analysis from the last reporting cycle by including preliminary thermomechanical analyses of cracked joints and implementation of dual-phase damage models.

  12. Trans-dimensional and hierarchical Bayesian approaches toward rigorous estimation of seismic sources and structures in the Northeast Asia

    NASA Astrophysics Data System (ADS)

    Kim, Seongryong; Tkalčić, Hrvoje; Mustać, Marija; Rhie, Junkee; Ford, Sean

    2016-04-01

    A framework is presented within which we provide rigorous estimations for seismic sources and structures in the Northeast Asia. We use Bayesian inversion methods, which enable statistical estimations of models and their uncertainties based on data information. Ambiguities in error statistics and model parameterizations are addressed by hierarchical and trans-dimensional (trans-D) techniques, which can be inherently implemented in the Bayesian inversions. Hence reliable estimation of model parameters and their uncertainties is possible, thus avoiding arbitrary regularizations and parameterizations. Hierarchical and trans-D inversions are performed to develop a three-dimensional velocity model using ambient noise data. To further improve the model, we perform joint inversions with receiver function data using a newly developed Bayesian method. For the source estimation, a novel moment tensor inversion method is presented and applied to regional waveform data of the North Korean nuclear explosion tests. By the combination of new Bayesian techniques and the structural model, coupled with meaningful uncertainties related to each of the processes, more quantitative monitoring and discrimination of seismic events is possible.

  13. Multi-community command and control systems in law enforcement: An introductory planning guide

    NASA Technical Reports Server (NTRS)

    Sohn, R. L.; Garcia, E. A.; Kennedy, R. D.

    1976-01-01

    A set of planning guidelines for multi-community command and control systems in law enforcement is presented. Essential characteristics and applications of these systems are outlined. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Program management techniques and joint powers agreements for multicommunity programs are discussed in detail. A description of a typical multi-community computer-aided dispatch system is appended.

  14. Joint Applications Pilot of the National Climate Predictions and Projections Platform and the North Central Climate Science Center: Delivering climate projections on regional scales to support adaptation planning

    NASA Astrophysics Data System (ADS)

    Ray, A. J.; Ojima, D. S.; Morisette, J. T.

    2012-12-01

    The DOI North Central Climate Science Center (NC CSC) and the NOAA/NCAR National Climate Predictions and Projections (NCPP) Platform and have initiated a joint pilot study to collaboratively explore the "best available climate information" to support key land management questions and how to provide this information. NCPP's mission is to support state of the art approaches to develop and deliver comprehensive regional climate information and facilitate its use in decision making and adaptation planning. This presentation will describe the evolving joint pilot as a tangible, real-world demonstration of linkages between climate science, ecosystem science and resource management. Our joint pilot is developing a deliberate, ongoing interaction to prototype how NCPP will work with CSCs to develop and deliver needed climate information products, including translational information to support climate data understanding and use. This pilot also will build capacity in the North Central CSC by working with NCPP to use climate information used as input to ecological modeling. We will discuss lessons to date on developing and delivering needed climate information products based on this strategic partnership. Four projects have been funded to collaborate to incorporate climate information as part of an ecological modeling project, which in turn will address key DOI stakeholder priorities in the region: Riparian Corridors: Projecting climate change effects on cottonwood and willow seed dispersal phenology, flood timing, and seedling recruitment in western riparian forests. Sage Grouse & Habitats: Integrating climate and biological data into land management decision models to assess species and habitat vulnerability Grasslands & Forests: Projecting future effects of land management, natural disturbance, and CO2 on woody encroachment in the Northern Great Plains The value of climate information: Supporting management decisions in the Plains and Prairie Potholes LCC. NCCSC's role in these projects is to provide the connections between climate data and running ecological models, and prototype these for future work. NCPP will develop capacities to provide enhanced climate information at relevant spatial and temporal scales, both for historical climate and projections of future climate, and will work to link expert guidance and understanding of modeling processes and evaluation of modeling with the use of numerical climate data. Translational information thus is a suite of information that aids in translation of numerical climate information into usable knowledge for applications, e.g. ecological response models, hydrologic risk studies. This information includes technical and scientific aspects including, but not limited to: 1) results of objective, quantitative evaluation of climate models & downscaling techniques, 2) guidance on appropriate uses and interpretation, i.e., understanding the advantages and limitations of various downscaling techniques for specific user applications, 3) characterizing and interpreting uncertainty, 4) Descriptions meaningful to applications, e.g. narratives. NCPP believes that translational information is best co-developed between climate scientists and applications scientists, such as the NC-CSC pilot.

  15. Numerical built-in method for the nonlinear JRC/JCS model in rock joint.

    PubMed

    Liu, Qunyi; Xing, Wanli; Li, Ying

    2014-01-01

    The joint surface is widely distributed in the rock, thus leading to the nonlinear characteristics of rock mass strength and limiting the effectiveness of the linear model in reflecting characteristics. The JRC/JCS model is the nonlinear failure criterion and generally believed to describe the characteristics of joints better than other models. In order to develop the numerical program for JRC/JCS model, this paper established the relationship between the parameters of the JRC/JCS and Mohr-Coulomb models. Thereafter, the numerical implement method and implementation process of the JRC/JCS model were discussed and the reliability of the numerical method was verified by the shear tests of jointed rock mass. Finally, the effect of the JRC/JCS model parameters on the shear strength of the joint was analyzed.

  16. Practical approach to subject-specific estimation of knee joint contact force

    PubMed Central

    Knarr, Brian A.; Higginson, Jill S.

    2015-01-01

    Compressive forces experienced at the knee can significantly contribute to cartilage degeneration. Musculoskeletal models enable predictions of the internal forces experienced at the knee, but validation is often not possible, as experimental data detailing loading at the knee joint is limited. Recently available data reporting compressive knee force through direct measurement using instrumented total knee replacements offer a unique opportunity to evaluate the accuracy of models. Previous studies have highlighted the importance of subject-specificity in increasing the accuracy of model predictions; however, these techniques may be unrealistic outside of a research setting. Therefore, the goal of our work was to identify a practical approach for accurate prediction of tibiofemoral knee contact force (KCF). Four methods for prediction of knee contact force were compared: (1) standard static optimization, (2) uniform muscle coordination weighting, (3) subject-specific muscle coordination weighting and (4) subject-specific strength adjustments. Walking trials for three subjects with instrumented knee replacements were used to evaluate the accuracy of model predictions. Predictions utilizing subject-specific muscle coordination weighting yielded the best agreement with experimental data, however this method required in vivo data for weighting factor calibration. Including subject-specific strength adjustments improved models’ predictions compared to standard static optimization, with errors in peak KCF less than 0.5 body weight for all subjects. Overall, combining clinical assessments of muscle strength with standard tools available in the OpenSim software package, such as inverse kinematics and static optimization, appears to be a practical method for predicting joint contact force that can be implemented for many applications. PMID:25952546

  17. Hybrid FSWeld-bonded joint fatigue behaviour

    NASA Astrophysics Data System (ADS)

    Lertora, Enrico; Mandolfino, Chiara; Gambaro, Carla; Pizzorni, Marco

    2018-05-01

    Aluminium alloys, widely used in aeronautics, are increasingly involved in the automotive industry due to the good relationship between mechanical strength and specific weight. The lightening of the structures is the first objective, which allows the decreasing in the weight in motion. The use of aluminium alloys has also seen the introduction of the Friction Stir Welding (FSW) technique for the production of structural overlapping joints. FSW allows us to weld overlap joints free from defects, but with the presence of a structural notch further aggravated by the presence of a "hook" defect near the edge of the weld. Furthermore, FSW presents a weld penetration area connected to the tool geometry and penetration. The experimental activity will be focused on the combination of two different joining techniques, which can synergistically improve the final joint resistance. In particular, the welding and bonding process most commonly known as weld-bonding is defined as a hybrid process, as it combines two different junction processes. In this paper we analyse FSWelded AA6082 aluminium alloy overlapped joint with the aim of quantitatively evaluating the improvement provided by the presence of an epoxy adhesive between the plates. After optimising the weld-bonding process, the mechanical behaviour of welded joints will be analysed by static and dynamic tests. The presence of the adhesive should limit the negative effect of the structural notch inevitable in a FSW overlapped joint.

  18. Imaging osteoarthritis in the knee joints using x-ray guided diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Zhang, Qizhi; Yuan, Zhen; Sobel, Eric S.; Jiang, Huabei

    2010-02-01

    In our previous studies, near-infrared (NIR) diffuse optical tomography (DOT) had been successfully applied to imaging osteoarthritis (OA) in the finger joints where significant difference in optical properties of the joint tissues was evident between healthy and OA finger joints. Here we report for the first time that large joints such as the knee can also be optically imaged especially when DOT is combined with x-ray tomosynthesis where the 3D image of the bones from x-ray is incorporated into the DOT reconstruction as spatial a priori structural information. This study demonstrates that NIR light can image large joints such as the knee in addition to finger joints, which will drastically broaden the clinical utility of our x-ray guided DOT technique for OA diagnosis.

  19. Evaluation of the chondral modeling theory using fe-simulation and numeric shape optimization

    PubMed Central

    Plochocki, Jeffrey H; Ward, Carol V; Smith, Douglas E

    2009-01-01

    The chondral modeling theory proposes that hydrostatic pressure within articular cartilage regulates joint size, shape, and congruence through regional variations in rates of tissue proliferation.The purpose of this study is to develop a computational model using a nonlinear two-dimensional finite element analysis in conjunction with numeric shape optimization to evaluate the chondral modeling theory. The model employed in this analysis is generated from an MR image of the medial portion of the tibiofemoral joint in a subadult male. Stress-regulated morphological changes are simulated until skeletal maturity and evaluated against the chondral modeling theory. The computed results are found to support the chondral modeling theory. The shape-optimized model exhibits increased joint congruence, broader stress distributions in articular cartilage, and a relative decrease in joint diameter. The results for the computational model correspond well with experimental data and provide valuable insights into the mechanical determinants of joint growth. The model also provides a crucial first step toward developing a comprehensive model that can be employed to test the influence of mechanical variables on joint conformation. PMID:19438771

  20. Glass Blowing -- Try It, You'll Like It.

    ERIC Educational Resources Information Center

    Dilavore, Philip

    1982-01-01

    Discusses the basics of scientific glassblowing, including equipment needed, lighting a hand torch (which uses a gas and oxygen mixture), and cutting tubing. Also discusses preparation of butt joints, tee joints, and bends. Photographs illustrating various techniques are provided. (JN)

Top