Sample records for joint programme cements

  1. Study of the Peak Shear Strength of a Cement-Filled Hard Rock Joint

    NASA Astrophysics Data System (ADS)

    She, Cheng-Xue; Sun, Fu-Ting

    2018-03-01

    The peak shear strength of a cement-filled hard rock joint is studied by theoretical analysis and laboratory testing. Based on the concept of the shear resistance angle, by combining the statistical method and fractal theory, three new parameters are proposed to characterize the three-dimensional joint morphology, reflecting the effects of the average roughness, multi-scale asperities and the dispersion degree of the roughness distribution. These factors are independent of the measurement scale, and they reflect the anisotropy of the joint roughness. Compressive shear tests are conducted on cement-filled joints. Because joints without cement can be considered special cement-filled joints in which the filling degree of cement is zero, they are also tested. The cement-filled granite joint fails primarily along the granite-cement interfaces. The filling degree of cement controls the joint failure and affects its mechanical behaviour. With a decrease in the filling degree of cement, the joint cohesion decreases; however, the dilatancy angle and the basic friction angle of the interface increase. As the filling degree approaches zero, the cohesion approaches zero, while the dilatancy angle and the basic friction angle increase to those of the joint without cement. A set of formulas is proposed to evaluate the peak shear strength of the joints with and without cement. The formulas are shown to be reasonable by comparison with the tested peak shear strength, and they reflect the anisotropy of the strength. This research deepens the understanding of cement-filled joints and provides a method to evaluate their peak shear strength.

  2. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  3. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  4. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  5. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  6. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  7. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  8. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  9. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  10. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal constrained cemented prosthesis... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal constrained cemented prosthesis. (a) Identification. A wrist joint metal constrained cemented prosthesis is a...

  11. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint (hemi-hip) acetabular metal cemented... (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular metal cemented prosthesis is a device intended to be implanted to replace a portion of the hip joint...

  12. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal constrained cemented or uncemented... metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained... Administration on or before December 26, 1996 for any hip joint metal constrained cemented or uncemented...

  13. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  14. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non... December 26, 1996 for any ankle joint metal/polymer non-constrained cemented prosthesis that was in...

  15. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  16. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  17. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  18. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non... December 26, 1996 for any ankle joint metal/polymer non-constrained cemented prosthesis that was in...

  19. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal/polymer constrained cemented or uncemented prosthesis is a device intended to be implanted to...

  20. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  1. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  2. 21 CFR 888.3120 - Ankle joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... substantially equivalent to an ankle joint metal/polymer non-constrained cemented prosthesis that was in... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/polymer non-constrained cemented... metal/polymer non-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer non...

  3. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  4. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  5. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  6. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  7. 21 CFR 888.3800 - Wrist joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal/polymer semi-constrained... Wrist joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A wrist joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a wrist joint...

  8. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  9. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  10. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  11. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  12. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer constrained... Knee joint femorotibial metal/polymer constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer constrained cemented prosthesis is a device intended to be implanted to replace part...

  13. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  14. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a...

  15. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  16. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  17. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace a...

  18. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  19. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal constrained cemented or uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained...

  20. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  1. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  2. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  3. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  4. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  5. 21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...

  6. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  7. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/composite semi-constrained... Ankle joint metal/composite semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/composite semi-constrained cemented prosthesis is a device intended to be implanted to replace an...

  8. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  9. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  10. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  11. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  12. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  13. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  14. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  15. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/composite semi-constrained cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal...

  16. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ankle joint metal/polymer semi-constrained cemented prosthesis. 888.3110 Section 888.3110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal...

  17. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint metal/polymer semi-constrained cemented prosthesis. 888.3160 Section 888.3160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal...

  18. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  19. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  20. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  1. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  2. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  3. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  4. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  5. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  6. 21 CFR 888.3640 - Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint metal/metal or metal/polymer... § 888.3640 Shoulder joint metal/metal or metal/polymer constrained cemented prosthesis. (a) Identification. A shoulder joint metal/metal or metal/polymer constrained cemented prosthesis is a device...

  7. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/composite semi-constrained cemented prosthesis is a two-part device intended to be implanted to replace a...

  8. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  9. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  10. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  11. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  12. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  13. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  14. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  15. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  16. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  17. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  18. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  19. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  20. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  1. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. 888.3560 Section 888.3560 Food and Drugs FOOD AND DRUG... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented...

  2. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  3. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. 888.3560 Section 888.3560 Food and Drugs FOOD AND DRUG... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented...

  4. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  5. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. 888.3560 Section 888.3560 Food and Drugs FOOD AND DRUG... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented...

  6. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  7. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. 888.3560 Section 888.3560 Food and Drugs FOOD AND DRUG... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented...

  8. 21 CFR 888.3560 - Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis. 888.3560 Section 888.3560 Food and Drugs FOOD AND DRUG... Devices § 888.3560 Knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented...

  9. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/polymer semi-constrained cemented prosthesis. 888.3350 Section 888.3350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  10. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metallic constrained... Knee joint femorotibial metallic constrained cemented prosthesis. (a) Identification. A knee joint... knee joint. The device prevents dislocation in more than one anatomic plane and has components that are...

  11. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits minimally (less than normal anatomic constraints) translation in one or...

  12. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits minimally (less than normal anatomic constraints) translation in one or...

  13. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint metal/polymer non-constrained... Shoulder joint metal/polymer non-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits minimally (less than normal anatomic constraints) translation in one or...

  14. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its...

  15. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its...

  16. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint metal/polymer semi-constrained... Shoulder joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A shoulder joint... shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its...

  17. Prevention of cement leakage into the hip joint by a standard cement plug during PFN-A cement augmentation: a technical note.

    PubMed

    Hanke, M; Djonov, V; Tannast, M; Keel, M J; Bastian, J D

    2016-06-01

    Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.

  18. Rehabilitation of jointed Portland cement concrete pavements : SPS-6--initial evaluation and analysis

    DOT National Transportation Integrated Search

    2005-10-01

    The Specific Pavement Studies 6 (SPS-6) experiment, "Rehabilitation of Jointed Portland Cement Concrete Pavements," was designed as a controlled field experiment that focuses on the study of specific rehabilitation design features of jointed plain co...

  19. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  20. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  1. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  2. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  3. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  4. 49 CFR 192.281 - Plastic pipe.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Plastic pipe. (a) General. A plastic pipe joint that is joined by solvent cement, adhesive, or heat fusion..., see § 192.7). (3) The joint may not be heated to accelerate the setting of the cement. (c) Heat-fusion joints. Each heat-fusion joint on plastic pipe must comply with the following: (1) A butt heat-fusion...

  5. 49 CFR 192.281 - Plastic pipe.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Plastic pipe. (a) General. A plastic pipe joint that is joined by solvent cement, adhesive, or heat fusion..., see § 192.7). (3) The joint may not be heated to accelerate the setting of the cement. (c) Heat-fusion joints. Each heat-fusion joint on plastic pipe must comply with the following: (1) A butt heat-fusion...

  6. 49 CFR 192.281 - Plastic pipe.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Plastic pipe. (a) General. A plastic pipe joint that is joined by solvent cement, adhesive, or heat fusion..., see § 192.7). (3) The joint may not be heated to accelerate the setting of the cement. (c) Heat-fusion joints. Each heat-fusion joint on plastic pipe must comply with the following: (1) A butt heat-fusion...

  7. 49 CFR 192.281 - Plastic pipe.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Plastic pipe. (a) General. A plastic pipe joint that is joined by solvent cement, adhesive, or heat fusion..., see § 192.7). (3) The joint may not be heated to accelerate the setting of the cement. (c) Heat-fusion joints. Each heat-fusion joint on plastic pipe must comply with the following: (1) A butt heat-fusion...

  8. Cemented total knee replacement in 24 dogs: surgical technique, clinical results, and complications.

    PubMed

    Allen, Matthew J; Leone, Kendall A; Lamonte, Kimberly; Townsend, Katy L; Mann, Kenneth A

    2009-07-01

    To characterize the performance of cemented total knee replacement (TKR) in dogs. Preclinical research study. Skeletally mature, male Hounds (25-30 kg; n=24) with no preexisting joint pathology. Dogs had unilateral cemented TKR and were evaluated at 6, 12, 26, or 52 weeks (6 dogs/time point) by radiography, bone density analysis, visual gait assessment, and direct measurement of thigh circumference and stifle joint range of motion as indicators of functional recovery. At study end, the stability of the cemented tibial component was determined by destructive mechanical testing. Joint stability was excellent in 16 dogs (67%) and good in 8 dogs. None of the tibial components had evidence of migration or periprosthetic osteolysis whereas 1 femoral component was loose at 52 weeks. There was an early and significant decrease in tibial bone density, likely because of disuse of the operated limb. Dogs returned to full activity by 12 weeks. The tibial cement-bone interface maintained its strength over 52 weeks. Cement provides stable fixation of the tibial component in canine TKR. Cemented TKR yields adequate clinical function and stifle joint excursion in the dog. Clinical studies are needed to determine the long-term fate of cemented TKR implants, to assess the influence of implant design on implant fixation and wear, and to obtain objective functional data.

  9. Feasibility study of fluxless brazing cemented carbides to steel

    NASA Astrophysics Data System (ADS)

    Tillmann, W.; Sievers, N.

    2017-03-01

    One of the most important brazing processes is the joints between cemented carbides and steel for the tool industry such as in rotary drill hammers or saw blades. Even though this technique has already been used for several decades, defects in the joint can still occur and lead to quality loss. Mostly, the joining process is facilitated by induction heating and the use of a flux to enhance the wetting of the filler alloy on the surface of the steel and cemented carbide in an ambient atmosphere. However, although the use of flux enables successful joining, it also generates voids within the joint, which reduces the strength of the connection while the chemicals within the flux are toxic and polluting. In this feasibility study, a fluxless brazing process is used to examine the joint between cemented carbides and steel for the first time. For this, ultrasound is applied during induction heating to enable the wetting between the liquid filler metal and the surfaces of the cemented carbide and steel. The ultrasound generates cavitations within the liquid filler metal, which remove the oxides from the surface. Several filler metals such as a silver based alloy Ag449, pure Zn, and an AlSi-alloy were used to reduce the brazing temperature and to lower the thermal residual stresses within the joint. As a result, every filler metal successfully wetted both materials and led to a dense connection. The ultrasound has to be applied carefully to prevent a damage of the cemented carbide. In this regard, it was observed that single grains of the cemented carbide broke out and remained in the joint. This positive result of brazing cemented carbides to steel without a flux but using ultrasound, allows future studies to focus on the shear strength of these joints as well as the behavior of the thermally induced residual stresses.

  10. Bone Repair and Military Readiness

    DTIC Science & Technology

    2012-10-25

    formation. Orthopedic surgeons have had to adapt surgical techniques to account for issues with cementing total joint prostheses and subsequent total joint ...the silorane composite has the potential to support osseous integration around the cemented total joint implant and may generate less immunogenic wear...factors, and potential for osseointegration/osseoinduction, this material has potential to be used for screw augmentation, total hip/knee joint

  11. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  12. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  13. 21 CFR 888.3790 - Wrist joint metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wrist joint metal constrained cemented prosthesis. 888.3790 Section 888.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3790 Wrist joint metal...

  14. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  15. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  16. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  17. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  18. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal constrained cemented or uncemented prosthesis. 888.3300 Section 888.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint...

  19. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  20. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint (hemi-hip) acetabular metal cemented prosthesis. 888.3370 Section 888.3370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint...

  1. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal constrained cemented or uncemented prosthesis. 888.3300 Section 888.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint...

  2. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal constrained cemented or uncemented prosthesis. 888.3300 Section 888.3300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint...

  3. Effects of Cementing on Ligament Balance During Total Knee Arthroplasty.

    PubMed

    Chow, Jimmy; Wang, Kevin; Elson, Leah; Anderson, Christopher; Roche, Martin

    2017-05-01

    Complications related to joint imbalance may contribute to some of the most predominant modes of failure in total knee arthroplasty (TKA). These complications include instability, aseptic loosening, asymmetric component wear, and idiopathic pain. Fixation may represent a step that introduces unchecked variability into the procedure and may contribute to the incidence of joint imbalance-related complications. The ability to quantify in vivo loading in the medial and lateral compartments would allow for the ability to confirm balance after fixation and prior to wound closure. This retrospective study sought to capture any variability and imbalance associated with cementing technique. A total of 93 patients underwent sensor-assisted TKA. All patients were confirmed to have quantifiably balanced joints prior to cementation. After cementing and final component placement, the sensor was reinserted into the joint to capture any cementation-induced changes in loading. Imbalance was observed in 44% of patients after cementation. There was no difference in the proportion of imbalance due to surgeon experience (P=.456), cement type (P=.429), or knee system (P=.792). A majority of knees exhibited loading increase in the medial compartment. It was concluded that cementation technique contributes to a significant amount of balance-related variability at the fixation stage of the procedure. The use of the sensor in this study allowed for the correction of all instances of imbalance prior to closure. More objective methods of balance verification may be important for ensuring optimal surgical outcomes. [Orthopedics. 2017; 40(3):e455-e459.]. Copyright 2017, SLACK Incorporated.

  4. Durability of saw-cut joints in plain cement concrete pavements.

    DOT National Transportation Integrated Search

    2011-01-01

    The objective of this project was to evaluate factors influencing the durability of the joints in portland cement concrete : pavement in the state of Indiana. Specifically this work evaluated the absorption of water, the absorption of deicing solutio...

  5. A novel liposomal drug delivery system for PMMA bone cements

    PubMed Central

    Birchall, James C.; Evans, Samuel L.; Denyer, Stephen P.

    2015-01-01

    Abstract The population in developed countries is ageing and the number of people experiencing joint‐related conditions, such as osteoarthritis, is expected to increase. Joint replacements are currently the most effective treatment for severe joint conditions and although many of these procedures are successful, infection developing after the procedure is still an issue, requiring complex and expensive revisions. Whilst incorporating a powdered antibiotic within the bone cement can reduce infection rates, the powder frequently agglomerates, resulting in poor antibiotic release characteristics and compromised mechanical performance of the cement. To overcome these issues, a novel delivery system consisting of antibiotic‐loaded nano‐sized liposomes was developed for inclusion into polymethyl methacrylate (PMMA) bone cement. This system was tested in a commercial cement (Palacos R) and consistently delivered a higher percentage (22%) of the incorporated antibiotic when compared to the powdered antibiotic cement (9%), meaning less antibiotic needs to be incorporated than with conventional cement. The novel system resulted in a controlled and gradual release of antibiotic over a longer, 30‐day period and enhanced the toughness, bending strength and Vickers hardness of the cement, without altering its polymerization or molecular structure. This new material has the potential to significantly reduce infections in cemented joint replacements leading to enhanced patient quality of life and reduced healthcare costs. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1510–1524, 2016. PMID:26256271

  6. Durability of saw-cut joints in plain cement concrete pavements : [technical summary].

    DOT National Transportation Integrated Search

    2011-01-01

    The main objective of this study was to evaluate factors influencing the durability of the joints in portland cement concrete pavement in the state of Indiana. : The scope of the research included the evaluation of the absorption of water in concrete...

  7. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Knee joint femorotibial metallic constrained cemented prosthesis. 888.3480 Section 888.3480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3480...

  8. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metallic constrained cemented prosthesis. 888.3480 Section 888.3480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3480...

  9. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/composite non-constrained cemented prosthesis. 888.3490 Section 888.3490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  10. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. 888.3500 Section 888.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  11. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. 888.3500 Section 888.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  12. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/composite non-constrained cemented prosthesis. 888.3490 Section 888.3490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  13. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metal/composite non-constrained cemented prosthesis. 888.3490 Section 888.3490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  14. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metallic constrained cemented prosthesis. 888.3480 Section 888.3480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3480...

  15. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. 888.3500 Section 888.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  16. 21 CFR 888.3480 - Knee joint femorotibial metallic constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Knee joint femorotibial metallic constrained cemented prosthesis. 888.3480 Section 888.3480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3480...

  17. The Use of Micro and Nano Particulate Fillers to Modify the Mechanical and Material Properties of Acrylic Bone Cement

    NASA Astrophysics Data System (ADS)

    Slane, Joshua A.

    Acrylic bone cement (polymethyl methacrylate) is widely used in total joint replacements to provide long-term fixation of implants. In essence, bone cement acts as a grout by filling in the voids left between the implant and the patient's bone, forming a mechanical interlock. While bone cement is considered the `gold standard' for implant fixation, issues such as mechanical failure of the cement mantle (aseptic loosening) and the development of prosthetic joint infection (PJI) still plague joint replacement procedures and often necessitate revision arthroplasty. In an effort to address these failures, various modifications are commonly made to bone cement such as mechanical reinforcement with particles/fibers and the addition of antibiotics to mitigate PJI. Despite these attempts, issues such as poor particle interfacial adhesion, inadequate drug release, and the development of multidrug resistant bacteria limit the effectiveness of bone cement modifications. Therefore, the overall goal of this work was to use micro and nanoparticles to enhance the properties of acrylic bone cement, with particular emphasis placed on improving the mechanical properties, cumulative antibiotic release, and antimicrobial properties. An acrylic bone cement (Palacos R) was modified with three types of particles in various loading ratios: mesoporous silica nanoparticles (for mechanical reinforcement), xylitol microparticles (for increased antibiotic release), and silver nanoparticles (as an antimicrobial agent). These particles were used as sole modifications, not in tandem with one another. The resulting cement composites were characterized using a variety of mechanical (macro to nano, fatigue, fracture, and dynamic), imaging, chemical, thermal, biological, and antimicrobial testing techniques. The primary outcomes of this dissertation demonstrate that: (1) mesoporous silica, as used in this work, is a poor reinforcement phase for acrylic bone cement, (2) xylitol can significantly increase the cumulative antibiotic release from acrylic cement, and (3) silver nanoparticles are a potential alternative to traditional antibiotics in cement, such as gentamicin.

  18. Analysis of Contraction Joint Width Influence on Load Stress of Pavement Panels

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Cui, Wei; Sun, Wei

    2018-05-01

    The width of transverse contraction joint of the cement road varies with temperatures, which leads to changes in load transmission among plates of the road surface and affects load stress of the road plates. Three-dimensional element analysis software EverFE is used to address the relation between the contraction joint width and road surface load stress, revealing the impact of reducing contraction joint width. The results could be of critical value in maintaining road functions and extending the service life of cement road surfaces.

  19. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/composite semi-constrained cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3340...

  20. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ankle joint metal/composite semi-constrained cemented prosthesis. 888.3100 Section 888.3100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3100...

  1. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/composite semi-constrained cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3340...

  2. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/composite semi-constrained cemented prosthesis. 888.3340 Section 888.3340 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3340...

  3. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ankle joint metal/composite semi-constrained cemented prosthesis. 888.3100 Section 888.3100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3100...

  4. 21 CFR 888.3100 - Ankle joint metal/composite semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ankle joint metal/composite semi-constrained cemented prosthesis. 888.3100 Section 888.3100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3100...

  5. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. 888.3390 Section 888.3390 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices...

  6. Cement arthroplasty for ankle joint destruction.

    PubMed

    Lee, Ho-Seong; Ahn, Ji-Yong; Lee, Jong-Seok; Lee, Jun-Young; Jeong, Jae-Jung; Choi, Young Rak

    2014-09-03

    The aim of this study was to investigate the outcomes of cement arthroplasty used as a primary salvage procedure to treat ankle joint destruction. This study included sixteen patients who underwent primary cement arthroplasty from May 2004 to March 2012 because of an ankle disorder, including intractable infection, nonunion, or a large bone defect or tumor. The mean age of the patients was fifty-seven years (range, twenty-three to seventy-four years), and the mean follow-up period was thirty-nine months (range, fourteen to 100 months). The cement spacer position, cement breakage, osteolysis around the inserted cement, and alignment of the joint were evaluated radiographically. American Orthopaedic Foot & Ankle Society (AOFAS) scores and visual analogue scale (VAS) pain scores were recorded preoperatively and at the time of final follow-up. Functional questionnaires were used to assess the duration for which the patient could walk continuously, use of walking aids, sports activity, consumption of pain medication, and the patient's subjective assessment of the percentage of overall improvement compared with before the cement arthroplasty. The cement spacer was retained without breakage for a mean of thirty-nine months (range, fourteen to 100 months). Osteolysis around the cement was observed in one patient at seventy-eight months, and subluxation developed in one patient. The mean AOFAS and VAS pain scores improved from 39 (range, 11 to 71) preoperatively to 70 (range, 47 to 88) postoperatively (p = 0.001) and from 8 (range, 4 to 9) to 3 (range, 1 to 7) (p = 0.001), respectively. At the final follow-up evaluation, nine of the sixteen patients did not require walking aids, ten used no pain medication, and nine were able to walk continuously for more than an hour. One patient complained of persistent pain and was considered to have had a failure of the procedure. Primary cement arthroplasty might be a treatment option for advanced ankle destruction in elderly and less active patients. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  7. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  8. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  9. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. 888.3320 Section 888.3320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic...

  10. Use of an absorbable membrane to position biologically inductive materials in the periprosthetic space of cemented joints.

    PubMed

    DiResta, Gene R; Brown, Holly; Aiken, Sean; Doty, Steven; Schneider, Robert; Wright, Timothy; Healey, John H

    2006-01-01

    A device is presented that positions ultrahigh molecular weight polyethylene (UHMWPE) debris against periprosthetic bone surfaces. This can facilitate the study of aseptic loosening associated with cemented joint prostheses by speeding the appearance of this debris within the periprosthetic space. The device, composed of a 100 microm thick bioabsorbable membrane impregnated with 1.4 x 10(9) sub-micron particles of UHMWPE debris, is positioned on the endosteum of the bone prior to the insertion of the cemented orthopedic implant. An in vitro pullout study and an in vivo canine pilot study were performed to investigate its potential to accelerate "time to aseptic loosening" of cemented prosthetic joints. Pullout studies characterized the influence of the membrane on initial implant fixation. The tensile stresses (mean+/-std.dev.) required to withdraw a prosthesis cemented into canine femurs with and without the membrane were 1.15+/-0.3 and 1.54+/-0.01 MPa, respectively; these findings were not significantly different (p > 0.4). The in vivo pilot study, involving five dogs, was performed to evaluate the efficacy of the debris to accelerate loosening in a canine cemented hip arthroplasty. Aseptic loosening and lameness occurred within 12 months, quicker than the 30 months reported in a retrospective clinical review of canine hip arthroplasty.

  11. Mechanical, material, and antimicrobial properties of acrylic bone cement impregnated with silver nanoparticles.

    PubMed

    Slane, Josh; Vivanco, Juan; Rose, Warren; Ploeg, Heidi-Lynn; Squire, Matthew

    2015-03-01

    Prosthetic joint infection is one of the most serious complications that can lead to failure of a total joint replacement. Recently, the rise of multidrug resistant bacteria has substantially reduced the efficacy of antibiotics that are typically incorporated into acrylic bone cement. Silver nanoparticles (AgNPs) are an attractive alternative to traditional antibiotics resulting from their broad-spectrum antimicrobial activity and low bacterial resistance. The purpose of this study, therefore, was to incorporate metallic silver nanoparticles into acrylic bone cement and quantify the effects on the cement's mechanical, material and antimicrobial properties. AgNPs at three loading ratios (0.25, 0.5, and 1.0% wt/wt) were incorporated into a commercial bone cement using a probe sonication technique. The resulting cements demonstrated mechanical and material properties that were not substantially different from the standard cement. Testing against Staphylococcus aureus and Staphylococcus epidermidis using Kirby-Bauer and time-kill assays demonstrated no antimicrobial activity against planktonic bacteria. In contrast, cements modified with AgNPs significantly reduced biofilm formation on the surface of the cement. These results indicate that AgNP-loaded cement is of high potential for use in primary arthroplasty where prevention of bacterial surface colonization is vital. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  13. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  14. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  15. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  16. 21 CFR 888.3353 - Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The... nonporous metal alloys, and used with or without bone cement. (b) Classification. Class II. [54 FR 48239...

  17. Joint sealant study

    DOT National Transportation Integrated Search

    1987-09-01

    ADOT has approximately 550 lane miles of jointed portland cement pavement under its jurisdiction. The current practice is to saw and seal the joints at the time of construction and reseal the joints under a rehabilitation project. ADOT does not speci...

  18. The effect of N-acetylcysteine on mechanical fatigue resistance of antibiotic-loaded bone cement.

    PubMed

    Sukur, Erhan; Akar, Abdulhalim; Topcu, Huseyin Nevzat; Cicekli, Ozgur; Kochai, Alauddin; Turker, Mehmet

    2018-05-31

    This biomechanical study evaluates the effect of N-acetylcysteine alone and in combination with the most commonly used antibiotic-loaded bone cement mixtures. We mixed eight bone cement mixture groups including combinations of N-acetylcysteine, gentamicin, teicoplanin, and vancomycin and applied a four-point bending test individually to each sample on days 1 and 15 using an MTS Acumen test device. The result was less than 50 MPa-the limit declared by the ISO (International Standards Organization)-in only the "gentamicin + bone cement + N-acetylcysteine" group. Mechanical fatigue resistance of the bone cement decreased significantly with the addition of N-acetylcysteine both on day 1 and day 15 (p <  0.001). With the addition of N-acetylcysteine into the "gentamicin + bone cement" and "vancomycin + bone cement" mixtures, a significant decrease in mechanical fatigue resistance was observed both on day 1 and day 15 (p <  0.001). In contrast, with the addition of N-acetylcysteine into the "teicoplanin + bone cement" mixture, no significant difference in mechanical fatigue resistance was observed on days 1 and 15 (p = 0.093, p = 0.356). Preliminary results indicate that adding N-acetylcysteine to teicoplanin-loaded bone cement does not significantly affect the cement's mechanical resistance, potentially leading to a new avenue for preventing and treating peri-prosthetic joint infection. N-acetylcysteine may, therefore, be considered as an alternative agent to be added to antibiotic-loaded bone cement mixtures used in the prevention of peri-prosthetic joint infection.

  19. Ageing and moisture uptake in polymethyl methacrylate (PMMA) bone cements.

    PubMed

    Ayre, Wayne Nishio; Denyer, Stephen P; Evans, Samuel L

    2014-04-01

    Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bone cements were aged in an isotonic fluid at physiological temperatures and changes in moisture uptake, microstructure and mechanical and fatigue properties were studied. Initial penetration of water into the cement followed Fickian diffusion and was thought to be caused by vacancies created by leaching monomer. An increase in weight of approximately 2% was experienced after 30 days ageing and was accompanied by hydrolysis of poly(methyl methacrylate) (PMMA) in the outermost layers of the cement. This molecular change and the plasticising effect of water resulted in reduced mechanical and fatigue properties over time. Cement ageing is therefore thought to be a key contributor in the long-term failure of cemented joint replacements. The results from this study have highlighted the need to develop cements capable of withstanding long-term degradation and for more accurate test methods, which fully account for physiological ageing. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Clumped isotopes reveal the influence of deformation style on fluid flow and cementation along the Moab Fault, Paradox Basin, Utah

    NASA Astrophysics Data System (ADS)

    Huntington, K. W.; Bergman, S.; Crider, J. G.

    2012-12-01

    Brittle fault systems can serve as either conduits or barriers to fluid flow, impacting mass and heat transfer in the crust and influencing the potential storage and migration of hydrocarbons and geothermal fluids. For fault systems in porous sandstones, different classes of structures control both hydrological and mechanical behavior during fault evolution: while cataclastic deformation bands form zones of localized deformation and crushed grains that reduce permeability within and across fault zones, joints can act as significant conduits for fluid. We investigate the relationship between structures and fluid flow in porous sandstones by studying calcite cements along the Moab Fault, a large normal fault system in the Paradox Basin, Utah. We use clumped isotope thermometry of fault cements to independently determine both the temperature and δ18O of the water from which the cements grew, placing new constraints on the source and path of diagenetic fluids in the basin. Based on fluid inclusion micro-thermometry and stable isotopic analysis of calcite cements from the Moab Fault, previous workers have hypothesized that joints served as conduits for the ascension of warm (84-125 °C) basinal fluids and deeply circulating meteoric waters. At the minor joint-dominated fault segment from which these data were collected, clumped isotope temperatures range from 57±10 to 101±2°C (2 SE), consistent with this hypothesis. However, at the nearby intersection of two major fault segments - in a zone characterized by both deformation bands and abundant joints - we find a broad range of temperatures (12±4 to 78±4°C) that vary spatially with distance from the fault and correlate with variations in secondary deformation structures (joints and deformation bands). These data provide the first evidence for cement growth from Earth surface-temperature fluids along the Moab Fault and suggests that the Fault served as a conduit for both ascending and descending fluids. The spatial distribution of low-temperature cements argues for rapid penetration of surface waters flowing down intensely-jointed fault intersections and suggests that deformation-band faults served as low-permeability baffles, preventing lateral migration of cold fluids. This interpretation is consistent with the cathodoluminescence patterns and δ18O and δ13C values of the samples, and confirms the important role of structures in transmission and compartmentalization of fluids in porous rocks. Our study illustrates how clumped isotope thermometry can aid in understanding interactions of mechanical, chemical, and transport processes associated with fractures and faults.

  1. Joint programmes in paediatric cardiothoracic surgery: a survey and descriptive analysis.

    PubMed

    DeCampli, William M

    2011-12-01

    Joint programmes, as opposed to regionalisation of paediatric cardiac care, may improve outcomes while preserving accessibility. We determined the prevalence and nature of joint programmes. We sent an online survey to 125 paediatric cardiac surgeons in the United States in November, 2009 querying the past or present existence of a joint programme, its mission, structure, function, and perceived success. A total of 65 surgeon responses from 65 institutions met the criteria for inclusion. Of the 65 institutions, 22 currently or previously conducted a joint programme. Compared with primary institutions, partner institutions were less often children's hospitals (p = 0.0004), had fewer paediatric beds (p = 0.005), and performed fewer cardiac cases (p = 0.03). Approximately 47% of partner hospitals performed fewer than 50 cases per year. The median distance range between hospitals was 41-60 miles, ranging from 5 to 1000 miles. Approximately 54% of partner hospitals had no surgeon working primarily on-site, and 31% of the programmes conducted joint conferences. Approximately 67% of the programmes limited the complexity of cases at the partner hospital, and 83% of the programmes had formal contracts between hospitals. Of the six programmes whose main mission was to increase referrals to the primary hospital, three were felt to have failed. Of the nine programmes whose mission was to increase regional quality, eight were felt to be successful. Joint programmes in paediatric cardiac surgery are common but are heterogeneous in structure and function. Programmes whose mission is to improve the quality of regional care seem more likely to succeed. Joint programmes may be a practical alternative to regionalisation to achieve better outcomes.

  2. Sawing and sealing joints in bituminous pavements to control cracking

    DOT National Transportation Integrated Search

    1996-03-01

    The practice of sawing and sealing joints in pavements is not a new one. In fact, it is common practice in the construction of jointed Portland Cement Concrete (PCC) pavements. The idea of sawing and sealing joints in bituminous pavements is much les...

  3. Towards an Analytical Framework for Understanding the Development of a Quality Assurance System in an International Joint Programme

    ERIC Educational Resources Information Center

    Zheng, Gaoming; Cai, Yuzhuo; Ma, Shaozhuang

    2017-01-01

    This paper intends to construct an analytical framework for understanding quality assurance in international joint programmes and to test it in a case analysis of a European--Chinese joint doctoral degree programme. The development of a quality assurance system for an international joint programme is understood as an institutionalization process…

  4. Ageing and moisture uptake in polymethyl methacrylate (PMMA) bone cements☆

    PubMed Central

    Ayre, Wayne Nishio; Denyer, Stephen P.; Evans, Samuel L.

    2014-01-01

    Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bone cements were aged in an isotonic fluid at physiological temperatures and changes in moisture uptake, microstructure and mechanical and fatigue properties were studied. Initial penetration of water into the cement followed Fickian diffusion and was thought to be caused by vacancies created by leaching monomer. An increase in weight of approximately 2% was experienced after 30 days ageing and was accompanied by hydrolysis of poly(methyl methacrylate) (PMMA) in the outermost layers of the cement. This molecular change and the plasticising effect of water resulted in reduced mechanical and fatigue properties over time. Cement ageing is therefore thought to be a key contributor in the long-term failure of cemented joint replacements. The results from this study have highlighted the need to develop cements capable of withstanding long-term degradation and for more accurate test methods, which fully account for physiological ageing. PMID:24445003

  5. Evaluation of a thin-bonded Portland cement concrete pavement overlay.

    DOT National Transportation Integrated Search

    1996-01-01

    This report discusses the performance of the Virginia Department of Transportation's first modern rehabilitation project involving a thin-bonded portland cement concrete overlay of an existing jointed concrete pavement. The performance of the rigid o...

  6. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone...

  7. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone...

  8. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone...

  9. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone...

  10. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone...

  11. [Effect of bone cement application on the incidence of deep vein thrombosis in major joint arthroplasties].

    PubMed

    Aslan, Ahmet; Ağar, Emre; Aydoğan, Nevres Hürriyet; Atay, Tolga; Baydar, Metin Lütfi; Kırdemir, Vecihi; Ozden, Ahmet

    2011-12-01

    In this study, we have investigated whether the application of bone cement has an effect on the frequency of deep vein thrombosis (DVT) in major joint arthroplasties (MJA). A total of 95 MJA cases meeting the inclusion criteria of this study between January 2004 and January 2005 were divided into cemented and cementless groups. For prophylaxis, all patients were given low molecular weight heparin (LMWH). The patients were scanned for DVT preoperatively and on the postoperative 12(th) day by color Doppler ultrasonography. In hip arthroplasties, in knee arthroplasties and in general, DVT was seen more frequently in cemented group, however, there was no statistically significant difference between groups in the frequency of DVT (p=0.549, p=0.749 and p=0.462, respectively). Also, there was no significant difference between the results of the different LMWH groups (p=0.616). The results of this study shows that bone cement application in MJAs such as hip or knee arthroplasties has no significant effect on the frequency of DVT.

  12. Non-autoclaved aerated concrete with mineral additives

    NASA Astrophysics Data System (ADS)

    Il'ina, L. V.; Rakov, M. A.

    2016-01-01

    We investigated the effect of joint grinding of Portland cement clinker, silica and carbonate components and mineral additives to specific surface of 280 - 300 m2/kg on the properties (strength, average density and thermal conductivity) of non-autoclaved aerated concrete, and the porosity of the hardened cement paste produced from Portland cement clinker with mineral additives. The joint grinding of the Portland cement clinker with silica and carbonate components and mineral additives reduces the energy consumption of non-autoclaved aerated concrete production. The efficiency of mineral additives (diopside, wollastonite) is due to the closeness the composition, the type of chemical bonds, physical and chemical characteristics (specific enthalpy of formation, specific entropy) to anhydrous clinker minerals and their hydration products. Considering the influence of these additions on hydration of clinker minerals and formation of hardened cement paste structure, dispersed wollastonite and diopside should be used as mineral additives. The hardness and, consequently, the elastic modulus of diopside are higher than that of hardened cement paste. As a result, there is a redistribution of stresses in the hardened cement paste interporous partitions and hardening, both the partitions and aerated concrete on the whole. The mineral additives introduction allowed to obtain the non-autoclaved aerated concrete with average density 580 kg/m3, compressive strength of 3.3 MPa and thermal conductivity of 0.131 W/(m.°C).

  13. Two-Stage Revision for Infected Total Knee Arthroplasty: Based on Autoclaving the Recycled Femoral Component and Intraoperative Molding Using Antibiotic-Impregnated Cement on the Tibial Side.

    PubMed

    Lee, Byoung-Joo; Kyung, Hee-Soo; Yoon, Seong-Dae

    2015-09-01

    The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. The mean range of knee joint motion was 70° prior to the first stage operation and 72° prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113° at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.

  14. Vacuum Brazing of WC-8Co Cemented Carbides to Carbon Steel Using Pure Cu and Ag-28Cu as Filler Metal

    NASA Astrophysics Data System (ADS)

    Zhang, X. Z.; Liu, G. W.; Tao, J. N.; Shao, H. C.; Fu, H.; Pan, T. Z.; Qiao, G. J.

    2017-02-01

    The wetting and spreading behavior of commercial pure Cu and Ag-28Cu alloy on WC-8Co cemented carbide were investigated by the sessile drop technique. The contact angle of both systems obviously decreases with moderately increasing the wetting temperature. Vacuum brazing of the WC-8Co cemented carbide to SAE1045 steel using the pure Cu or Ag-28Cu as filler metal was further carried out based on the wetting results. The interfacial interactions and joint mechanical behavior involving microhardness, shear strength and fracture were analyzed and discussed. An obvious Fe-Cu-Co transition layer is detected at the WC-8Co/Cu interface, while no obvious reaction layer is observed at the whole WC-8Co/Ag-28Cu/SAE1045 brazing seam. The microhardness values of the two interlayers and the steel substrate near the two interlayers increase more or less, while those of WC-8Co cemented carbide substrates adjacent to the two interlayers decrease. The WC-8Co/SAE1045 joints using pure Cu and Ag-28Cu alloy as filler metals obtain average shear strength values of about 172 and 136 MPa, and both of the joint fractures occur in the interlayers.

  15. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  16. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  17. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  18. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  19. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... component is intended to be fixed with bone cement. The acetabular component is intended for use without bone cement (§ 888.3027). (b) Classification. Class III. (c) Date PMA or notice of completion of a PDP...

  20. A case report: reconstruction of a damaged knee following treatment of giant cell tumor of the proximal tibia with cryosurgery and cementation.

    PubMed

    Wakitani, S; Imoto, K; Saito, M; Yamamoto, T; Kawabata, H

    2002-05-01

    Reconstruction of a knee damaged by cement packed to cure a giant-cell tumor is sometimes difficult. We reconstructed such a knee by removal of the cement, autologous bone transplantation and distraction osteogenesis using the Ilizarov apparatus. In this paper the results 29 months after the salvage surgery are given. We saw a 31-year-old woman's knee joint that showed osteoarthritic change after curettage, cryosurgery and cementation performed 4 years previously for a giant-cell tumor of the proximal tibia. We reconstructed the knee joint. This procedure included cement removal, alignment correction by tibial osteotomy, subchondral bone reconstruction by autologous bone transplantation, and filling the defect after removing the bone cement by elongating the diaphysis using the Ilizarov apparatus. Distraction was terminated 4 months later when 54 mm of elongation was performed. All devices were removed 12 months after the surgery. Seventeen months after the removal of the apparatus, the range of motion of the right knee was 0 degrees extension and 110 degrees flexion, and the patient was able to walk without pain. Although the treatment period is long and there may be some complications of Ilizarov lengthening and distraction osteogenesis, this procedure has numerous benefits. Bony defects can be soundly reconstructed and, at the same time, the alignment of the knee can be corrected. Also it is not necessary to reconstruct the ligaments because the insertions are intact. If osteoarthritis progresses, a surface type total knee replacement can be performed, not constrained type prosthesis, which would be used if the bony structure had not been reconstructed. This procedure may be one of the candidates for reconstructing such knee joints destroyed by bone cement. Copyright 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.

  1. Joint sealant materials for concrete pavement repairs.

    DOT National Transportation Integrated Search

    1991-01-01

    This report on joint sealant materials for concrete pavement repairs is based on conversations with specialists from several states, the Federal Highway Administration, the Portland Cement Association, and the American Concrete Pavement Association, ...

  2. Overcoming boundaries of worldwide joint arthroplasty registers: the European Arthroplasty Register minimal dataset.

    PubMed

    Sadoghi, Patrick; Leithner, Andreas; Labek, Gerold

    2013-09-01

    Worldwide joint arthroplasty registers are instrumental to screen for complications or implant failures. In order to achieve comparable results a similar classification dataset is essential. The authors therefore present the European Federation of National Associations of Orthopaedics and Traumatology (EFORT) European Arthroplasty Register (EAR) minimal dataset for primary and revision joint arthroplasty. Main parameters include the following: date of operation, country, hospital ID-code, patient's name and prename, birthday, identification code of the implant, gender, diagnosis, preoperations, type of prosthesis (partial, total), side, cementation technique, use of antibiotics in the cement, surgical approach, and others specifically related to the affected joint. The authors believe that using this minimal dataset will improve the chance for a worldwide comparison of arthroplasty registers and ask future countries for implementation. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...

  4. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...

  5. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...

  6. 21 CFR 888.3510 - Knee joint femorotibial metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...-and-socket joint located between a stemmed femoral and a stemmed tibial component and a runner and track joint between each pair of femoral and tibial condyles. The ball-and-socket joint is composed of a...-molybdenum. The ball of the tibial component is held within the socket of the femoral component by the...

  7. New method for antibiotic release from bone cement (polymethylmethacrylate): Redefining boundaries.

    PubMed

    Carbó-Laso, E; Sanz-Ruiz, P; Del Real-Romero, J C; Ballesteros-Iglesias, Y; Paz-Jiménez, E; Arán-Ais, F; Sánchez-Navarro, M; Pérez-Limiñana, M A; López-Torres, I; Vaquero-Martín, J

    The increasing antimicrobial resistance is promoting the addition of antibiotics with high antistaphylococcal activity to polymethylmethacrylate (PMMA), for use in cement spacers in periprosthetic joint infection. Linezolid and levofloxacin have already been used in in-vitro studies, however, rifampicin has been shown to have a deleterious effect on the mechanical properties of PMMA, because it inhibits PMMA polymerization. The objective of our study was to isolate the rifampicin during the polymerization process using microencapsulation techniques, in order to obtain a PMMA suitable for manufacturing bone cement spacers. Microcapsules of rifampicin were synthesized with alginate and PHBV, using Rifaldin ® . The concentration levels of rifampicin were studied by UV-visible spectrophotometry. Compression, hardness and setting time tests were performed with CMW ® 1 cement samples alone, with non-encapsulated rifampicin and with alginate or PHBV microcapsules. The production yield, efficiency and microencapsulation yield were greater with alginate (P = .0001). The cement with microcapsules demonstrated greater resistance to compression than the cement with rifampicin (91.26±5.13, 91.35±6.29 and 74.04±3.57 MPa in alginate, PHBV and rifampicin, respectively) (P = .0001). The setting time reduced, and the hardness curve of the cement with alginate microcapsules was similar to that of the control. Microencapsulation with alginate is an appropriate technique for introducing rifampicin into PMMA, preserving compression properties and setting time. This could allow intraoperative manufacturing of bone cement spacers that release rifampicin for the treatment of periprosthetic joint infection. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Deterioration of jointed Portland cement concrete pavements.

    DOT National Transportation Integrated Search

    1975-01-01

    Information has been gathered regarding the performance of more than 400 lane-miles of jointed PCC interstate pavements located in five construction districts in Virginia. The factors causing pavement deterioration have been identified, the processes...

  9. Alternatives to Full-Depth Patching on Resurfacing Projects

    DOT National Transportation Integrated Search

    1993-09-01

    The vast majority of Illinois' non-interstate network is constructed of jointed Portland cement concrete (PCC). Typically, Illinois' first significant rehabilitation efforts for jointed PCC pavements are in the form of full-depth bituminous concrete ...

  10. 21 CFR 888.3660 - Shoulder joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3660... device are: (1) FDA's: (i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical... metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a...

  11. 21 CFR 888.3650 - Shoulder joint metal/polymer non-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3650... are: (1) FDA's: (i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices... metal/polymer non-constrained cemented prosthesis is a device intended to be implanted to replace a...

  12. National Apprenticeship Standards for Cement Masonry, Asphalt, and Composition Trade. Revised.

    ERIC Educational Resources Information Center

    Employment and Training Administration (DOL), Washington, DC. Bureau of Apprenticeship and Training.

    These national standards are designed to guide local joint apprenticeship and training committees in establishing local apprenticeship programs to train individuals seeking to become skilled in the cement masonry, asphalt, and composition trade. Covered in the individual sections are the following topics: provisions of the apprenticeship standards…

  13. In vivo performance of a reduced-modulus bone cement

    NASA Astrophysics Data System (ADS)

    Forehand, Brett Ramsey

    Total joint replacement has become one of the most common procedures in the area of orthopedics and is often the solution in patients with diseased or injured hip joints. Component loosening is a significant problem and is primarily caused by bone resorption at the bone-cement interface in cemented implants. It is our hypothesis that localized shear stresses are responsible for the resorption. It was previously shown analytically that local stresses at the interface could be reduced by using a cement of lower modulus. A new reduced modulus cement, polybutyl methylmethacrylate (PBMMA), was developed to test the hypothesis. PBMMA was formulated to exist as polybutyl methacrylate filler in a polymethyl methacrylate matrix. The success of PBMMA cement is based largely on the fact that the polybutyl component of the cement will be in the rubbery state at body temperature. In vitro characterization of the cement was undertaken previously and demonstrated a modulus of approximately one-eighth that of conventional bone cement, polymethyl methacrylate (PMMA) and increased fracture toughness. The purpose of this experiment was to perform an in vivo comparison of the two cements. A sheep model was selected. Total hip arthroplasty was performed on 50 ewes using either PBMMA or PMMA. Radiographs were taken at 6 month intervals. At one year, the contralateral femur of each sheep was implanted so that each animal served as its own control, and the animals were sacrificed. The stiffness of the bone-cement interface of the femoral component within the femur was assessed by applying a torque to the femoral component and demonstrated a significant difference in loosening between the cements when the specimens were tested in external rotation (p < 0.007). Evaluation of the mechanical data also suggests that the PBMMA sheep had a greater amount of loosening for each subject, 59% versus 4% for standard PMMA. A radiographic analysis demonstrated more signs of loosening in the PMMA series of subjects. A brief histological examination showed similar bony reaction to both cements, however, study of the interface membrane was not able to be accomplished. Reasons for the rejection of the hypothesis are discussed.

  14. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    PubMed

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  15. Effect of a 6-week dynamic neuromuscular training programme on ankle joint function: A Case report

    PubMed Central

    2011-01-01

    Background Ankle joint sprain and the subsequent development of chronic ankle instability (CAI) are commonly encountered by clinicians involved in the treatment and rehabilitation of musculoskeletal injuries. It has recently been advocated that ankle joint post-sprain rehabilitation protocols should incorporate dynamic neuromuscular training to enhance ankle joint sensorimotor capabilities. To date no studies have reported on the effects of dynamic neuromuscular training on ankle joint positioning during landing from a jump, which has been reported as one of the primary injury mechanisms for ankle joint sprain. This case report details the effects of a 6-week dynamic neuromuscular training programme on ankle joint function in an athlete with CAI. Methods The athlete took part in a progressive 6-week dynamic neuromuscular training programme which incorporated postural stability, strengthening, plyometric, and speed/agility drills. The outcome measures chosen to assess for interventional efficacy were: [1] Cumberland Ankle Instability Tool (CAIT) scores, [2] Star Excursion Balance Test (SEBT) reach distances, [3] ankle joint plantar flexion during drop landing and drop vertical jumping, and [4] ground reaction forces (GRFs) during walking. Results CAIT and SEBT scores improved following participation in the programme. The angle of ankle joint plantar flexion decreased at the point of initial contact during the drop landing and drop vertical jumping tasks, indicating that the ankle joint was in a less vulnerable position upon landing following participation in the programme. Furthermore, GRFs were reduced whilst walking post-intervention. Conclusions The 6-week dynamic neuromuscular training programme improved parameters of ankle joint sensorimotor control in an athlete with CAI. Further research is now required in a larger cohort of subjects to determine the effects of neuromuscular training on ankle joint injury risk factors. PMID:21658224

  16. Effect of a 6-week dynamic neuromuscular training programme on ankle joint function: A Case report.

    PubMed

    O'Driscoll, Jeremiah; Kerin, Fearghal; Delahunt, Eamonn

    2011-06-09

    Ankle joint sprain and the subsequent development of chronic ankle instability (CAI) are commonly encountered by clinicians involved in the treatment and rehabilitation of musculoskeletal injuries. It has recently been advocated that ankle joint post-sprain rehabilitation protocols should incorporate dynamic neuromuscular training to enhance ankle joint sensorimotor capabilities. To date no studies have reported on the effects of dynamic neuromuscular training on ankle joint positioning during landing from a jump, which has been reported as one of the primary injury mechanisms for ankle joint sprain. This case report details the effects of a 6-week dynamic neuromuscular training programme on ankle joint function in an athlete with CAI. The athlete took part in a progressive 6-week dynamic neuromuscular training programme which incorporated postural stability, strengthening, plyometric, and speed/agility drills. The outcome measures chosen to assess for interventional efficacy were: 1 Cumberland Ankle Instability Tool (CAIT) scores, 2 Star Excursion Balance Test (SEBT) reach distances, 3 ankle joint plantar flexion during drop landing and drop vertical jumping, and 4 ground reaction forces (GRFs) during walking. CAIT and SEBT scores improved following participation in the programme. The angle of ankle joint plantar flexion decreased at the point of initial contact during the drop landing and drop vertical jumping tasks, indicating that the ankle joint was in a less vulnerable position upon landing following participation in the programme. Furthermore, GRFs were reduced whilst walking post-intervention. The 6-week dynamic neuromuscular training programme improved parameters of ankle joint sensorimotor control in an athlete with CAI. Further research is now required in a larger cohort of subjects to determine the effects of neuromuscular training on ankle joint injury risk factors.

  17. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  18. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  19. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  20. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  1. 21 CFR 888.3535 - Knee joint femorotibial (uni-compartmental) metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... across-the-joint. This generic type of device is designed to achieve biological fixation to bone without the use of bone cement. This identification includes fixed-bearing knee prostheses where the ultra...

  2. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  3. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  4. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  5. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  6. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  7. Partial-depth repair of jointed PCC pavements : cast-in-place and precast procedures.

    DOT National Transportation Integrated Search

    1977-01-01

    The installation of durable patches on jointed portland cement concrete pavement using several types of cast-in-place concrete, is described. The recommended procedures for pavement preparation and patch installation are given, and additional mainten...

  8. Cementless Oxford medial unicompartimental knee replacement: an independent series with a 5-year-follow-up.

    PubMed

    Panzram, Benjamin; Bertlich, Ines; Reiner, Tobias; Walker, Tilman; Hagmann, Sébastien; Gotterbarm, Tobias

    2017-07-01

    Cemented unicompartmental knee replacement (UKR) has proven excellent long-term survival rates and functional scores in Price et al. (Clin Orthop Relat Res 435:171-180, 2005), Price and Svard (Clin Orthop Relat Res 469(1):174-179, 2011) and Murray et al. (Bone Joint Surg Br 80(6):983-989, 1998). The main causes for revision, aseptic loosening and pain of unknown origin might be addressed by cementless UKR in Liddle et al. (Bone Joint J 95-B(2):181-187, 2013), Pandit et al. (J Bone Joint Surg Am 95(15):1365-1372, 2013), National Joint Registry for England, Wales and Northern Ireland: 10th Annual Report 2013 ( http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/10th_annual_report/NJR%2010th%20Annual%20Report%202013%20B.pdf , 2013), Swedish Knee Arthroplasty Register: Annual Report 2013 ( http://www.myknee.se/pdf/SKAR2013_Eng.pdf , 2013). This single-centre retrospective cohort study reports the 5-year follow-up results of our first 30 consecutively implanted cementless Oxford UKR (OUKR). Clinical outcome was measured using the OKS, AKSS, range of movement and level of pain (visual analogue scale). The results were compared to cemented OUKR in a matched-pair analysis. Implant survival was 89.7%. One revision each was performed due to tibial fracture, progression of osteoarthritis (OA) and inlay dislocation. The 5-year survival rate of the cementless group was 89.7% and of the cemented group 94.1%. Both groups showed excellent postoperative clinical scores. Cementless fixation shows good survival rates and clinical outcome compared to cemented fixation.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugama, Toshifumi; Pyatina, Tatiana

    The study aims at evaluating the bond durability of a carbon microfiber (CMF)-reinforced alkali-activating calcium aluminate cement (CAC)/fly ash F (FAF) blend cementitious material adhering to carbon steel (CS) under stresses induced by a 350°C heat-25°Cwater cooling cycle. This cementitious material/CS joint sample was originally prepared in an autoclave at 300°C under a pressure of 8.3 MPa. For comparison, two reference geothermal well cements, Class G modified with silica (G) and calciumaluminum phosphate (CaP), were employed as well reinforced with CMF. In the CAC/FAF blending cement systems, the CAC-derived cementitious reaction products preferentially adhered to CS surfaces, rather than thatmore » of FAF-related reaction products. CMF played a pivotal role in creating tough interfacial bond structure of cement layer adhering to CS. The bond toughness also was supported by the crystalline cementitious reaction products including sodalite, brownmillerite, and hedenbergite as major phases, and aragonite, boehmite, and garronite as minor ones. The brownmillerite as an interfacial reaction product between cement and CS promoted the chemical bonding of the cement to CS, while the other phases served in providing the attractive bonding of the cement to CS. The post-stress-test joint samples revealed the formation of additional brown-millerite, aragonite, and garronite, in particular brownmillerite as the major one. The combination of chemical bonding and self-advancing adherence behavior of the cement was essential for creating a better interfacial bond structure. A similar interfacial bond structure was observed with CaP. The crystalline phase composition of the autoclaved cement revealed apatite, zeolite, and ferrowyllieite as major reaction products, and aragonite and al-katoite as the minor ones. Ferrowyllieite was identified as cement/CS interfacial reaction product contributing to the chemical bond of cement, while the other phases aided in providing the attractive bond of cement. After a stress test, two phases, ferrowyllieite and aragonite, promoted the self-advancing adherence of cement to CS. However, the effectiveness of these phases in improving adherence performance of cement was less than that of CAC/FAF blend cement, reflecting the fact that the bond durability of CAC/FAF blend cement was far better than that of the CaP. In contrast, the autoclaved silica-modified G cement consisting of xonotlite, and 0.9 nm-to-bermorite and riversideite, with calcite as the crystalline reaction products, had no significant effect on improving the shear bond strength and the bond’s toughness. No interaction product with CS was found in the cement adhering to CS. After a stress test, the calcite phase acted only to promote the self-advancing adherence of cement, but its extent was minimal compared with that of the other cements, thereby resulting in poor bond durability.« less

  10. Basic Hand Tools for Bricklaying and Cement Masonry [and] Basic Hand Tools of the Carpenter.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    Intended for student use, this unit discusses and illustrates the tools used in brick and masonry and carpentry. Contents of the brick and masonry section include informative materials on bricklaying tools (brick trowels, joint tools, levels, squares, line and accessories, rules, hammers and chisels, tool kits) and cement masonry tools (tampers,…

  11. Effect of Fly-Ash on Corrosion Resistance Characteristics of Rebar Embedded in Recycled Aggregate Concrete

    NASA Astrophysics Data System (ADS)

    Revathi, Purushothaman; Nikesh, P.

    2018-04-01

    In the frame of an extended research programme dealing with the utilization of recycled aggregate in concrete, the corrosion resistance characteristics of rebars embedded in recycled aggregate concrete is studied. Totally five series of concrete mixtures were prepared with fly-ash as replacement for cement in the levels of 10-30% by weight of cement. Corrosion studies by 90 days ponding test, linear polarization test and impressed voltage tests were carried out, in order to investigate whether corrosion behaviour of the rebars has improved due to the replacement of cement with fly-ash. Results showed that the replacement of cement with fly-ash in the range of 20-30% improves the corrosion resistance characteristics of recycled aggregate concrete.

  12. Full-depth repair of jointed PCC pavements cast-in-place and precast procedures.

    DOT National Transportation Integrated Search

    1976-01-01

    The deterioration of jointed portland cement concrete (PCC) pavements on the interstate system in Virginia has created a need for full-depth and partial-depth repairs. In this report, efforts related to full-depth repairs are described and discussed,...

  13. Bond Durability of Carbon-Microfiber-Reinforced Alkali-Activated High-Temperature Cement Adhering to Carbon Steel

    DOE PAGES

    Sugama, Toshifumi; Pyatina, Tatiana

    2017-02-01

    The study aims at evaluating the bond durability of a carbon microfiber (CMF)-reinforced alkali-activating calcium aluminate cement (CAC)/fly ash F (FAF) blend cementitious material adhering to carbon steel (CS) under stresses induced by a 350°C heat-25°Cwater cooling cycle. This cementitious material/CS joint sample was originally prepared in an autoclave at 300°C under a pressure of 8.3 MPa. For comparison, two reference geothermal well cements, Class G modified with silica (G) and calciumaluminum phosphate (CaP), were employed as well reinforced with CMF. In the CAC/FAF blending cement systems, the CAC-derived cementitious reaction products preferentially adhered to CS surfaces, rather than thatmore » of FAF-related reaction products. CMF played a pivotal role in creating tough interfacial bond structure of cement layer adhering to CS. The bond toughness also was supported by the crystalline cementitious reaction products including sodalite, brownmillerite, and hedenbergite as major phases, and aragonite, boehmite, and garronite as minor ones. The brownmillerite as an interfacial reaction product between cement and CS promoted the chemical bonding of the cement to CS, while the other phases served in providing the attractive bonding of the cement to CS. The post-stress-test joint samples revealed the formation of additional brown-millerite, aragonite, and garronite, in particular brownmillerite as the major one. The combination of chemical bonding and self-advancing adherence behavior of the cement was essential for creating a better interfacial bond structure. A similar interfacial bond structure was observed with CaP. The crystalline phase composition of the autoclaved cement revealed apatite, zeolite, and ferrowyllieite as major reaction products, and aragonite and al-katoite as the minor ones. Ferrowyllieite was identified as cement/CS interfacial reaction product contributing to the chemical bond of cement, while the other phases aided in providing the attractive bond of cement. After a stress test, two phases, ferrowyllieite and aragonite, promoted the self-advancing adherence of cement to CS. However, the effectiveness of these phases in improving adherence performance of cement was less than that of CAC/FAF blend cement, reflecting the fact that the bond durability of CAC/FAF blend cement was far better than that of the CaP. In contrast, the autoclaved silica-modified G cement consisting of xonotlite, and 0.9 nm-to-bermorite and riversideite, with calcite as the crystalline reaction products, had no significant effect on improving the shear bond strength and the bond’s toughness. No interaction product with CS was found in the cement adhering to CS. After a stress test, the calcite phase acted only to promote the self-advancing adherence of cement, but its extent was minimal compared with that of the other cements, thereby resulting in poor bond durability.« less

  14. The Measurement Of Total Joint Loosening By X-Ray Photogrammetry

    NASA Astrophysics Data System (ADS)

    Lippert, Frederick G.; Veress, Sandor A.; Tiwari, Rama S.; Harrington, Richard M.

    1980-07-01

    Failure of total joint replacement due to loosening of the composents either between the implant and cement or between the cement and bone is emerging as a late complication with an incidence as high as 20 percent. Loosening may not only cause pain but progressive loss of support for the prosthesis with eventual structural failure. Early diagnosis is important so that revision may be carried when deterioration or pain occurs. No method is currently available which clearly establishes loosening at an early stage except surgical exploration. We have devised a method based on our in vivo photogrammetry studies of patellar tracking patterns using metallic markers placed in bone near both components of the total joint. Stereo x-rays taken with the joint loaded and unloaded are measured for relative motion between the implant and the metallic markers. Laboratory studies using prosthetic hip components mounted in plastic bone have revealed the ability of this method to detect pistoning movements as small as 80 microns. These findings were confirmed by physical measurements.

  15. UHPC and NSFRC in Severe Environmental Conditions

    NASA Astrophysics Data System (ADS)

    Rehacek, S.; Citek, D.; Kolisko, J.

    2017-10-01

    Structure and properties of cement composite are time-varying characteristics, depending among others on environmental conditions. The key idea is a struggle for complex research of joint effect of physical, chemical and dynamic loads on the internal structure of cement composite and understanding the correlation between changes in microstructure and macro-scale properties. During the experimental program, specimens will be exposed to combined influence of freeze-thaw cycles, aggressive chemical agents and dynamic loading. The aim is to create a theoretical basis for design of effective cement composites meant to be used in severe environmental conditions.

  16. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device includes prostheses that consist of a metallic stem made of alloys, such as cobalt-chromium-molybdenum, with an integrated cylindrical trunnion bearing at the upper end of the stem that fits into a... head of the device to rotate on its stem. The prosthesis is intended for use with bone cement (§ 888...

  17. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... device includes prostheses that consist of a metallic stem made of alloys, such as cobalt-chromium-molybdenum, with an integrated cylindrical trunnion bearing at the upper end of the stem that fits into a... head of the device to rotate on its stem. The prosthesis is intended for use with bone cement (§ 888...

  18. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... device includes prostheses that consist of a metallic stem made of alloys, such as cobalt-chromium-molybdenum, with an integrated cylindrical trunnion bearing at the upper end of the stem that fits into a... head of the device to rotate on its stem. The prosthesis is intended for use with bone cement (§ 888...

  19. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... device includes prostheses that consist of a metallic stem made of alloys, such as cobalt-chromium-molybdenum, with an integrated cylindrical trunnion bearing at the upper end of the stem that fits into a... head of the device to rotate on its stem. The prosthesis is intended for use with bone cement (§ 888...

  20. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... device includes prostheses that consist of a metallic stem made of alloys, such as cobalt-chromium-molybdenum, with an integrated cylindrical trunnion bearing at the upper end of the stem that fits into a... head of the device to rotate on its stem. The prosthesis is intended for use with bone cement (§ 888...

  1. Advanced Pavement Design: Finite Element Modeling for Rigid Pavement Joints, Report II: Model Development

    DOT National Transportation Integrated Search

    1998-03-01

    The contribution of a cement-stabilized base course to the strength of the rigid pavement structure is poorly understood. The objective of this research was to obtain data on the response of the rigid pavement slab-joint-foundation system by conducti...

  2. Control of reflection cracking in a fabric-reinforced overlay on jointed portland cement concrete pavement.

    DOT National Transportation Integrated Search

    1982-01-01

    A study of the installation and three-year performance evaluation of a fabric-reinforced bituminous concrete overlay of a jointed concrete pavement is reported. The fabric, a polypropylene in an asphaltic mastic, was shown to act as a significant det...

  3. Artificial fusion of the knee joint with intramedullary nail and acrylic cementation following radical excision for tumor.

    PubMed

    Persson, B M; Rydholm, A

    1984-01-01

    Extensive local excisions of skeletal tumors in the knee region create reconstruction problems with several alternative solutions. Custom-made endoprostheses now compete with joint homografts and fusion with autogenous bone-grafts. Artificial fusion utilizing an extra long Küntscher-nail and acrylic cement as a spacer is a fourth possibility with the advantages of immediate ambulation and weight-bearing, here presented in two cases. The expected disadvantages of loosening in long time survivors can be taken care of using one of the above-mentioned alternatives. This revision can be made after completion of adjunctive chemotherapy or later when called for by the occurrence of pain or instability.

  4. Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

    PubMed

    Wee, Hwabok; Armstrong, April D; Flint, Wesley W; Kunselman, Allen R; Lewis, Gregory S

    2015-11-01

    Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p < 0.05). Bone with high stress was also correlated with both glenoid width and implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Monitoring the integrity of the cement-metal interface of total joint components in vitro using acoustic emission and ultrasound.

    PubMed

    Davies, J P; Tse, M K; Harris, W H

    1996-08-01

    Debonding of the cement-metal interface of cemented femoral components of total hip arthroplasty has been shown from clinical and autopsy material to be a common occurrence. Experimentally, debonding has been shown to increase markedly the strains in the adjacent cement mantle. Studies of autopsy-retrieved specimens demonstrate that debonding of the cement-metal interface is a key initiating event in loosening of cemented femoral components of total hip arthroplasty. However, both the radiographic and autopsy evidence of cement-metal interfacial debonding exist after the fact, that is, after debonding has occurred. The lack of prospective data showing that debonding does indeed occur under physiologic loading and occurs prior to other forms of failure of fixation leaves uncertain the issue of debonding and its role in initiating loosening of cemented femoral components. Knowing when, where, and to what extent the cement-metal interface debonds is critical information in understanding the process of loosening of cemented femoral components. Such information would contribute to improving the durability of stems and improving cementing techniques. In this study, the two nondestructive techniques of acoustic emission and ultrasonic evaluation of the cement-metal interface of cemented femoral stems of total hip arthroplasty were combined to investigate when, where, and to what extent cement-metal debonding occurred in vitro in simulated femurs loaded physiologically in fatigue in simulated single-leg stance. Debonding of the cement-metal interface of a cemented femoral component in this model was both an initiating event and a major mechanism of compromise of the cement-metal interface. Additional acoustic emission signals arose from cracks that developed in the cement.

  6. Influences of Shear History and Infilling on the Mechanical Characteristics and Acoustic Emissions of Joints

    NASA Astrophysics Data System (ADS)

    Meng, Fanzhen; Zhou, Hui; Wang, Zaiquan; Zhang, Liming; Kong, Liang; Li, Shaojun; Zhang, Chuanqing

    2017-08-01

    Filled joints, which are characterized by high deformability and low shear strength, are among the most critical discontinuities in rock mass and may be sheared repeatedly when subject to cyclic loading. Shear tests were carried out on tension splitting joints, with soil and granular cement mortar particles used as infillings, and the effects of the shear history on the mechanical behavior and acoustic emission (AE) of clean and filled joints were studied. The maximum strength in the subsequent shears was approximately 60% of the peak strength of the first shear for a clean joint, and the friction angle degraded from 63° to 45° after the first shear. The maximum shear strength of the filled joints was lower than 35% of the peak strength of the clean joint under the same normal stress. The change in the shear strength of filled joints with the number of shearing cycles was closely related to the transformation of the shear medium. Rolling friction occurred and the shear strength was low for the granular particle-filled joint, but the strength was elevated when the particles were crushed and sliding friction occurred. The AEs were significantly reduced during the second shear for the clean joint, and the peak AEs were mainly obtained at or near the turning point of the shear stress curve for the filled joint. The AEs were the highest for the cement particle-filled joint and lowest for the dry soil-filled joint; when subjected to repeated shears, the AEs were more complex because of the continuous changes to the shear medium. The evolution of the AEs with the shear displacement can accurately reflect the shear failure mechanism during a single shear process.

  7. Influence of Superplasticizer-Microsilica Complex on Cement Hydration, Structure and Properties of Cement Stone

    NASA Astrophysics Data System (ADS)

    Ivanov, I. M.; Kramar, L. Ya; Orlov, A. A.

    2017-11-01

    According to the study results, the influence of complex additives based on microsilica and superplasticizers on the processes of the heat release, hydration, hardening, formation of the structure and properties of cement stone was determined. Calorimetry, derivatography, X-ray phase analysis, electronic microscopy and physical-mechanical methods for analyzing the properties of cement stone were used for the studies. It was established that plasticizing additives, in addition to the main water-reducing and rheological functions, regulate cement solidification and hardening while polycarboxylate superplasticizers even contribute to the formation of a special, amorphized microstructure of cement stone. In a complex containing microsilica and a polycarboxylate superplasticizer the strength increases sharply with a sharp drop in the capillary porosity responsible for the density, permeability, durability, and hence, the longevity of concrete. All this is a weighty argument in favor of the use of microsilica jointly with a polycarboxylate superplasticizer in road concretes operated under aggressive conditions.

  8. Probabilistic analysis of the influence of the bonding degree of the stem-cement interface in the performance of cemented hip prostheses.

    PubMed

    Pérez, M A; Grasa, J; García-Aznar, J M; Bea, J A; Doblaré, M

    2006-01-01

    The long-term behavior of the stem-cement interface is one of the most frequent topics of discussion in the design of cemented total hip replacements, especially with regards to the process of damage accumulation in the cement layer. This effect is analyzed here comparing two different situations of the interface: completely bonded and debonded with friction. This comparative analysis is performed using a probabilistic computational approach that considers the variability and uncertainty of determinant factors that directly compromise the damage accumulation in the cement mantle. This stochastic technique is based on the combination of probabilistic finite elements (PFEM) and a cumulative damage approach known as B-model. Three random variables were considered: muscle and joint contact forces at the hip (both for walking and stair climbing), cement damage and fatigue properties of the cement. The results predicted that the regions with higher failure probability in the bulk cement are completely different depending on the stem-cement interface characteristics. In a bonded interface, critical sites appeared at the distal and medial parts of the cement, while for debonded interfaces, the critical regions were found distally and proximally. In bonded interfaces, the failure probability was higher than in debonded ones. The same conclusion may be established for stair climbing in comparison with walking activity.

  9. 24 CFR 3280.605 - Joints and connections.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of the fitting. Plastic pipe and copper tubing shall be inserted to the full depth of the solder cup..., cutting oil and foreign matter shall be removed. Pipe joint cement or thread lubricant shall be of... connected to a public water system, made with solder having not more than 0.2 percent lead. (4) Plastic pipe...

  10. 24 CFR 3280.605 - Joints and connections.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of the fitting. Plastic pipe and copper tubing shall be inserted to the full depth of the solder cup..., cutting oil and foreign matter shall be removed. Pipe joint cement or thread lubricant shall be of... connected to a public water system, made with solder having not more than 0.2 percent lead. (4) Plastic pipe...

  11. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... type of device is designed to achieve biological fixation to bone without the use of bone cement. This... bearing is rigidly secured to the metal tibial base plate. (b) Classification. Class II (special controls). The special control is FDA's guidance: “Class II Special Controls Guidance Document: Knee Joint...

  12. Effect of Post-Braze Heat Treatment on the Microstructure and Shear Strength of Cemented Carbide and Steel Using Ag-Based Alloy

    NASA Astrophysics Data System (ADS)

    Winardi, Y.; Triyono; Muhayat, N.

    2018-03-01

    The aim of the present study was to investigate the effect temperature of heat treatment process on the interfacial microstructure and mechanical properties of cemented carbide/carbon steel single lap joint brazed using Ag based alloy filler metal. The brazing process was carried out using torch brazing. Heat treatment process was carried out in induction furnace on the temperature of 700, 725, and 750°C, for 30 minutes. Microstructural examinations and phase analysis were performed using scanning electron microscopy (SEM) equipped with energy dispersion spectrometry (EDS). Shear strength of the joints was measured by the universal testing machine. The results of the microstructural analyses of the brazed area indicate that the increase temperature of treatment lead to the increase of solid solution phase of enrichted Cu. Based on EDS test, the carbon elements spread to all brazed area, which is disseminated by base metals. Shear strength joint is increased with temperature treatment. The highest shear strength of the brazed joint was 214,14 MPa when the heated up at 725°C.

  13. Temperature and composition of carbonate cements record early structural control on cementation in a nascent deformation band fault zone: Moab Fault, Utah, USA

    NASA Astrophysics Data System (ADS)

    Hodson, Keith R.; Crider, Juliet G.; Huntington, Katharine W.

    2016-10-01

    Fluid-driven cementation and diagenesis within fault zones can influence host rock permeability and rheology, affecting subsequent fluid migration and rock strength. However, there are few constraints on the feedbacks between diagenetic conditions and structural deformation. We investigate the cementation history of a fault-intersection zone on the Moab Fault, a well-studied fault system within the exhumed reservoir rocks of the Paradox Basin, Utah, USA. The fault zone hosts brittle structures recording different stages of deformation, including joints and two types of deformation bands. Using stable isotopes of carbon and oxygen, clumped isotope thermometry, and cathodoluminescence, we identify distinct source fluid compositions for the carbonate cements within the fault damage zone. Each source fluid is associated with different carbonate precipitation temperatures, luminescence characteristics, and styles of structural deformation. Luminescent carbonates appear to be derived from meteoric waters mixing with an organic-rich or magmatic carbon source. These cements have warm precipitation temperatures and are closely associated with jointing, capitalizing on increases in permeability associated with fracturing during faulting and subsequent exhumation. Earlier-formed non-luminescent carbonates have source fluid compositions similar to marine waters, low precipitation temperatures, and are closely associated with deformation bands. The deformation bands formed at shallow depths very early in the burial history, preconditioning the rock for fracturing and associated increases in permeability. Carbonate clumped isotope temperatures allow us to associate structural and diagenetic features with burial history, revealing that structural controls on fluid distribution are established early in the evolution of the host rock and fault zone, before the onset of major displacement.

  14. Optimisation of a two-liquid component pre-filled acrylic bone cement system: a design of experiments approach to optimise cement final properties.

    PubMed

    Clements, James; Walker, Gavin; Pentlavalli, Sreekanth; Dunne, Nicholas

    2014-10-01

    The initial composition of acrylic bone cement along with the mixing and delivery technique used can influence its final properties and therefore its clinical success in vivo. The polymerisation of acrylic bone cement is complex with a number of processes happening simultaneously. Acrylic bone cement mixing and delivery systems have undergone several design changes in their advancement, although the cement constituents themselves have remained unchanged since they were first used. This study was conducted to determine the factors that had the greatest effect on the final properties of acrylic bone cement using a pre-filled bone cement mixing and delivery system. A design of experiments (DoE) approach was used to determine the impact of the factors associated with this mixing and delivery method on the final properties of the cement produced. The DoE illustrated that all factors present within this study had a significant impact on the final properties of the cement. An optimum cement composition was hypothesised and tested. This optimum recipe produced cement with final mechanical and thermal properties within the clinical guidelines and stated by ISO 5833 (International Standard Organisation (ISO), International standard 5833: implants for surgery-acrylic resin cements, 2002), however the low setting times observed would not be clinically viable and could result in complications during the surgical technique. As a result further development would be required to improve the setting time of the cement in order for it to be deemed suitable for use in total joint replacement surgery.

  15. Release of zirconia nanoparticles at the metal stem-bone cement interface in implant loosening of total hip replacements.

    PubMed

    Schunck, Antje; Kronz, Andreas; Fischer, Cornelius; Buchhorn, Gottfried Hans

    2016-02-01

    In a previous failure analysis performed on femoral components of cemented total hip replacements, we determined high volumes of abraded bone cement. Here, we describe the topography of the polished surface of polymethyl methacrylate (PMMA) bone cement containing zirconia radiopacifier, analyzed by scanning electron microscopy and vertical scanning interferometry. Zirconia spikes protruded about 300nm from the PMMA matrix, with pits of former crystal deposition measuring about 400nm in depth. We deduced that the characteristically mulberry-shaped agglomerates of zirconia crystals are ground and truncated into flat surfaces and finally torn out of the PMMA matrix. Additionally, evaluation of in vitro PMMA-on-PMMA articulation confirmed that crystal agglomerations of zirconia were exposed to grain pullout, fatigue, and abrasion. In great quantities, micron-sized PMMA wear and zirconia nanoparticles accumulate in the cement-bone interface and capsular tissues, thereby contributing to osteolysis. Dissemination of nanoparticles to distant lymph nodes and organs of storage has been reported. As sufficient information is lacking, foreign body reactions to accumulated nanosized zirconia in places of long-term storage should be investigated. The production of wear particles of PMMA bone cement in the interface to joint replacement devices, presents a local challenge. The presence of zirconia particles results in frustrated digestion attempts by macrophages, liberation of inflammatory mediators, and necrosis leading to aseptic inflammation and osteolyses. Attempts to minimize wear of articulating joints reduced the attention to the deterioration of cement cuffs. We therefore investigated polished surfaces of retrieved cuffs to demonstrate their morphology and to measure surface roughness. Industrially admixed agglomerates of the radiopacifier are abraded to micron and nano-meter sized particles. The dissemination of zirconia particles in the reticulo-endothelial system to storage organs is a possible burden. Research to replace the actual contrast media by non-particulate material deserves more attention. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices... Medical Devices—Part I: Evaluation and Testing,’ ” (ii) “510(k) Sterility Review Guidance of 2/12/90 (K90... device intended to be implanted to replace part of a knee joint in the treatment of primary...

  17. Assessment of mitigating transverse joint faulting on portland cement concrete pavement with polyurethane foam on LA 1 Bypass, state project number 034-30-0023.

    DOT National Transportation Integrated Search

    2015-02-01

    A case study was conducted by the Louisiana Transportation Research Center (LTRC) to assess the effectiveness of reducing faulting on jointed concrete : pavement (JCP) with polyurethane foam (PF) on LA 1 Bypass, S.P. 034-30-0023. The PF fault correct...

  18. [Microbial settlement of paint- and building-materials in the sphere of drinking water. 9. Communication: experimental examination of cement mortar for the lining with tiles (author's transl)].

    PubMed

    Schoenen, D; Thofern, E

    1981-12-01

    The observation of a microbial growth in form of macrocolonies upon the joints of a tiled drinking water reservoir caused the microbiological testing of different pure mineral and some plastic containing cement mortar. Besides the conditions allowing the growth of macrocolonies on tiled plates with a construction like in a reservoir were examined.

  19. Promoting interdisciplinary education - the Vienna Doctoral Programme on Water Resource Systems

    NASA Astrophysics Data System (ADS)

    Blöschl, G.; Carr, G.; Bucher, C.; Farnleitner, A. H.; Rechberger, H.; Wagner, W.; Zessner, M.

    2011-11-01

    The Vienna Doctoral Programme on Water Resource Systems (DK-WRS) is a programme that aims to educate students in interdisciplinary water science through cutting edge research at an international level. It is funded by the Austrian Science Fund and designed to run over a period of 12 yr during which 80 doctoral students are anticipated to graduate. This paper reports on our experiences of setting up and implementing the Programme. We identify three challenges: integrating the disciplines, maintaining depth in an interdisciplinary programme, and teaching subjects remote to each student's core expertise. To address these challenges we adopted a number of approaches. We use three levels of instruments to foster integration across the disciplines: joint groups (e.g. a joint study programme), joint science questions (e.g. developed in annual symposia), and joint study sites. To maintain depth we apply a system of quality control including regular feedback sessions, theses by journal publications and international study exchange. For simultaneously teaching students from civil and environmental engineering, biology, geology, chemistry, mathematics we use visually explicit teaching, learning by doing, extra mentoring and by cross relating associated subjects. Our initial assessment of the Programme shows some very positive outcomes. Joint science questions formed between students from various disciplines indicate integration is being achieved. The number of successful publications in top journals suggests that depth is maintained. Positive feedback from the students on the variety and clarity of the courses indicates the teaching strategy is working well. Our experiences have shown that implementing and running an interdisciplinary doctoral programme has its challenges and is demanding in terms of time and human resources but seeing interactions progress and watching people grow and develop their way of thinking in an interdisciplinary environment is a valuable reward.

  20. Promoting interdisciplinary education - the Vienna Doctoral Programme on Water Resource Systems

    NASA Astrophysics Data System (ADS)

    Blöschl, G.; Carr, G.; Bucher, C.; Farnleitner, A. H.; Rechberger, H.; Wagner, W.; Zessner, M.

    2012-02-01

    The Vienna Doctoral Programme on Water Resource Systems (DK-WRS) is a programme that aims to educate students in interdisciplinary water science through cutting edge research at an international level. It is funded by the Austrian Science Fund and designed to run over a period of 12 yr during which 80 doctoral students are anticipated to graduate. This paper reports on our experiences of setting up and implementing the Programme. We identify three challenges: integrating the disciplines, maintaining depth in an interdisciplinary programme, and teaching subjects remote to each student's core expertise. To address these challenges we adopt a number of approaches. We use three levels of instruments to foster integration across the disciplines: joint groups (e.g. a joint study programme), joint science questions (e.g. developed in annual symposia), and joint study sites. To maintain depth we apply a system of quality control including regular feedback sessions, theses by journal publications and international study exchange. For simultaneously teaching students from civil and environmental engineering, biology, geology, chemistry, mathematics we use visually explicit teaching, learning by doing, extra mentoring and by cross relating associated subjects. Our initial assessment of the Programme shows some very positive outcomes. Joint science questions formed between students from various disciplines indicate integration is being achieved. The number of successful publications in top journals suggests that depth is maintained. Positive feedback from the students on the variety and clarity of the courses indicates the teaching strategy is working well. Our experiences have shown that implementing and running an interdisciplinary doctoral programme has its challenges and is demanding in terms of time and human resources but seeing interactions progress and watching people grow and develop their way of thinking in an interdisciplinary environment is a valuable reward.

  1. Working better together: joint leadership development for doctors and managers.

    PubMed

    Kelly, Nicola

    2014-01-01

    Traditionally, there have been tensions between frontline healthcare professionals and managers, with well-known stereotypes of difficult consultants and pen-pushing managers. Many junior doctors have limited management experience and have often never even met a manager prior to taking on a consultant role. Based on a successful programme pioneered by Dr Robert Klaber (Imperial, London) we have set-up an innovative scheme for Birmingham Children's Hospital, pairing junior doctors and managers to learn and work together. Our aim was to cultivate positive attitudes and understanding between the two groups, break down inter-professional barriers, and to provide practical leadership experience and education. We recruited 60 managers and doctors to participate in shadowing, conversation, and quality improvement projects. Thought-provoking online materials, blogs, socials, and popular monthly workshops consisting of patient-focused debate and discussion around key leadership themes, have helped to support learning and cement shared values. Formal evaluation has demonstrated an improvement in how participants perceive their knowledge and ability based on key NHS Leadership Framework competencies. Participant feedback has been extremely positive, and everyone plans to continue to incorporate Paired Learning into their continuing professional development. We are now embedding Paired Learning in the on-going educational programme offered at Birmingham Children's Hospital, whilst looking at extending the scheme to include different professional groups and other trusts across the region and nationally.

  2. Complexity in modeling of residual stresses and strains during polymerization of bone cement: effects of conversion, constraint, heat transfer, and viscoelastic property changes.

    PubMed

    Gilbert, Jeremy L

    2006-12-15

    Aseptic loosening of cemented joint prostheses remains a significant concern in orthopedic biomaterials. One possible contributor to cement loosening is the development of porosity, residual stresses, and local fracture of the cement that may arise from the in-situ polymerization of the cement. In-situ polymerization of acrylic bone cement is a complex set of interacting processes that involve polymerization reactions, heat generation and transfer, full or partial mechanical constraint, evolution of conversion- and temperature-dependent viscoelastic material properties, and thermal and conversion-driven changes in the density of the cement. Interactions between heat transfer and polymerization can lead to polymerization fronts moving through the material. Density changes during polymerization can, in the presence of mechanical constraint, lead to the development of locally high residual strain energy and residual stresses. This study models the interactions during bone cement polymerization and determines how residual stresses develop in cement and incorporates temperature and conversion-dependent viscoelastic behavior. The results show that the presence of polymerization fronts in bone cement result in locally high residual strain energies. A novel heredity integral approach is presented to track residual stresses incorporating conversion and temperature dependent material property changes. Finally, the relative contribution of thermal- and conversion-dependent strains to residual stresses is evaluated and it is found that the conversion-based strains are the major contributor to the overall behavior. This framework provides the basis for understanding the complex development of residual stresses and can be used as the basis for developing more complex models of cement behavior.

  3. Policy Goals of European Integration and Competitiveness in Academic Collaborations: An Examination of Joint Master's and Erasmus Mundus Programmes

    ERIC Educational Resources Information Center

    Papatsiba, Vassiliki

    2014-01-01

    This study examines policy goals pertaining to joint Master's in Europe as presented in Bologna-related and Erasmus Mundus (EM) policy texts. The profile of joint programmes has risen in the aftermath of the Bologna Process (BP), together with the launch of the EU EM. Despite a European policy tradition of cooperation in higher education (HE),…

  4. In vivo response of bioactive PMMA-based bone cement modified with alkoxysilane and calcium acetate.

    PubMed

    Sugino, Atsushi; Ohtsuki, Chikara; Miyazaki, Toshiki

    2008-11-01

    The use of polymethylmethacrylate (PMMA)-based bone cement is popular in orthopedics for the fixation of artificial joints with bone. However, it has a major problem with prostheses loosening because of coverage by fibrous tissue after long-term implantation. Recently, a bioactive bone cement has been developed that shows direct bonding to living bone through modification of PMMA resin with gamma-methacryloxypropyltrimethoxysilane (MPS) and calcium acetate. The cement is designed to exhibit bioactivity, through incorporation of silanol groups and calcium ions. Thus, it has the potential to form a layer of bone-like hydroxyapatite, which is essential for achieving direct bonding to living bone. This type of modification allows the cement to show spontaneous hydroxyapatite formation on its surface in a simulated body fluid after one day, and there is evidence of osteoconduction of the cement in rabbit tibia for periods of more than three weeks. However, the influence of the dissolved ions from the modified cement has not yet been clarified. Thus, the authors focused on the dissolution of the modified PMMA-based bone cement and its tissue response in muscle and bone by comparison with the behavior of non-modified PMMA-based bone cement. One week after implantation in the latissimus dorsi of a rabbit, the modified PMMA-based bone cement showed more inflammatory width than the commercial cement. However, four weeks after implantation, the inflammatory width of both cements was essentially the same. The osteoconductivity around the modified cement was higher than that for the conventional cement after four weeks implantation. These results indicate that the initial dissolution of calcium acetate from the modified cement to form the hydroxyapatite induced the acute inflammation around tissue, but also developed the osteoconductivity. It is suggested that the initial inflammation can be effective for inducing osteoconduction through a bone healing reaction when the material provides an environment that promotes bone formation.

  5. Use of antibiotic-impregnated cement during hip and knee arthroplasty in the United States.

    PubMed

    Heck, D; Rosenberg, A; Schink-Ascani, M; Garbus, S; Kiewitt, T

    1995-08-01

    A survey of practicing orthopaedists regarding their use of antibiotic(s) in bone-cement (ABC) was carried out. The initial sampling of 2,139 orthopaedists spanned the continental United States. Responses that passed fail-edit criteria were obtained from 1,015 physicians. Clinical practice patterns are highly variable. Adult reconstructive orthopaedic practitioners' belief in antibiotic(s) in bone-cement for the treatment of patients with previous sepsis is favorable. This opinion can be supported at the guideline level. Guidelines suggesting that liquid antibiotics should not be used as additions to polymethyl methacrylate are also supportable. The need for careful scientific inquiry and cost-effectiveness evaluation of the benefits and risks relating to the use of antibiotic additions to polymethyl methacrylate cement in joint arthroplasty exists. On the basis of such inquiry, educational dissemination to reduce practice variation would be indicated.

  6. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  7. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  8. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  9. 49 CFR 192.283 - Plastic pipe: Qualifying joining procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Materials Other Than by Welding § 192.283 Plastic pipe: Qualifying joining procedures. (a) Heat fusion... for making plastic pipe joints by a heat fusion, solvent cement, or adhesive method, the procedure...

  10. [The injection of acrylic bone cement prevents bone collapse in the intercalar bones lacking bony support: an experimental sheep semilunar bone model].

    PubMed

    Unsal, Murat; Tetik, Cihangir; Erol, Bülent; Cabukoğlu, Cengiz

    2003-01-01

    In a sheep semilunar bone model, we investigated whether collapse in the intercalar bones lacking bony support could be prevented by the injection of acrylic bone cement. The study included 16 limbs of eight sheep. Preoperatively, anteroposterior and lateral views of the carpal joints in the fore limbs were obtained. The animals were divided into four groups. In group 1 (n=3) no surgical procedure was performed in the right semilunar bones, whereas the periosteum on the contralateral side was elevated (group 2; n=3). The first two groups were left as controls. In Group 3 (n=5) the left semilunar bones were filled with acrylic bone cement following decancellation of the bone, while the right semilunar bones were left decancellated (group 4; n=5). The sheep were monitored for three months. Radiographs of the carpal joints were obtained to evaluate collapse occurrence in the semilunar bones. Thereafter, the animals were sacrificed and the semilunar bones were excised for biomechanical and histological examinations. Osteonecrosis and cartilage damage were sought and resistance to compressive forces was investigated. Radiologically, the extent of collapse was statistically significant in the semilunar bones in group 4 (p<0.05). The use of acrylic bone cement was found to prevent collapse in group 3, with no significant difference being noted between preoperative and postoperative semilunar bone heights (p>0.05). Biomechanically, the least resistance to compressive forces was measured in group 4 (p<0.05). Histologically, cartilage damage and osteonecrosis were only seen in group 4. Our data suggest that the use of acrylic bone cement prevents collapse in the semilunar bones, without inducing any cartilage damage or osteonecrosis.

  11. Liquid-solid phase transition alloy as reversible and rapid molding bone cement.

    PubMed

    Yi, Liting; Jin, Chao; Wang, Lei; Liu, Jing

    2014-12-01

    Acrylic bone cement has been an essential non-metallic implant used as fixing agent in the cemented total joint arthroplasty (THA). However, the currently available materials based mainly on polymethylmethacrylate (PMMA) still encounter certain limitations, such as time-consuming polymerization, thermal and chemical necrosis and troublesome revision procedure. Here from an alternative way, we proposed for the first time to adopt the injectable alloy cement to address such tough issues through introducing its unique liquid-solid phase transition mechanism. A typical cement along this way is thus made of an alloy Bi/In/Sn/Zn with a specifically designed low melting point 57.5 °C, which enables its rapid molding into various desired shapes with high plasticity and ultimate metallic behaviors. The fundamental characteristics including the mechanical strength, biocompatibility and phase transition-induced thermal effects have been clarified to demonstrate the importance of such alloy as unconventional cement with favorable merits. In addition, we also disclosed its advantage as an excellent contrast agent for radiation imaging on the bone interior structure which is highly beneficial for guiding the surgery and monitoring the therapeutic effects. Particularly, the proposed alloy cement with reversible phase transition feature significantly simplifies the revision of the cement and prosthesis. This study opens the way for employing the injectable alloy materials as reversible bone cement to fulfill diverse clinical needs in the coming time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Staged Reimplantation of a Total Hip Prosthesis After Co-infection with Candida tropicalis and Staphylococcus haemolyticus: A Case Report.

    PubMed

    Sebastian, Sujeesh; Malhotra, Rajesh; Pande, Ashish; Gautam, Deepak; Xess, Immaculata; Dhawan, Benu

    2018-06-01

    Fungal prosthetic joint infection is a rare complication in total joint arthroplasty. There are no established guidelines for management of these infections. We present a case of a 53-year-old male with a hip joint prosthesis co-infected with Candida tropicalis and Staphylococcus haemolyticus. A two-stage exchange arthroplasty was performed. The patient underwent implant removal, debridement, irrigation with saline solution and application of cement spacer impregnated with vancomycin followed by aggressive antimicrobial treatment in first stage. Complete eradication of infection was demonstrated by negative culture of sonicated cement spacer fluid and negative 16S rRNA and 18S rRNA gene PCR of sonicate fluid, synovial fluid and periprosthetic tissue samples. He underwent second-stage revision hip arthroplasty after 9 months of the first stage. At the latest follow-up, there was no evidence of recurrence of infection. This case illustrates the utility of sonication of biomaterials and molecular techniques for microbiological confirmation of absence of infection in staged surgeries which is required for a successful outcome.

  13. Structured Doctoral Education in Hannover - Joint Programme IMPRS-GW and geo-Q RTG

    NASA Astrophysics Data System (ADS)

    Kawazoe, Fumiko; Bruns, Sandra

    2018-02-01

    Two structured doctoral programmes that we have in Hannover, the IMPRS on Gravitational Wave Astronomy and SFB on relativistic geodesy and gravimetry with quantum sensors geo-Q, have not only become major resources for education in each field but have also started to provide substantial synergy to members of both programmes. Our strong crossdisciplinary approach to create a joint programme has received excellent feedback not only from researchers inside the programme but also from various external committee. Building on experience that we have acquired over the last decade, we propose to set up a common doctoral programme within the international gravitational wave astronomy and physics. We envisage that with a common doctoral programme we will create a strong team of young researchers who will carry on building a strong network of third generation gravitational wave detectors and observatories.

  14. Does adding antibiotics to cement reduce the need for early revision in total knee arthroplasty?

    PubMed

    Bohm, Eric; Zhu, Naisu; Gu, Jing; de Guia, Nicole; Linton, Cassandra; Anderson, Tammy; Paton, David; Dunbar, Michael

    2014-01-01

    There is considerable debate about whether antibiotic-loaded bone cement should be used for fixation of TKAs. While antibiotics offer the theoretical benefit of lowering early revision due to infection, they may weaken the cement and thus increase the likelihood of aseptic loosening, perhaps resulting in a higher revision rate. We (1) compared the frequency of early knee revision arthroplasty in patients treated with antibiotic-loaded or non-antibiotic-loaded cement for initial fixation, (2) determined effects of age, sex, comorbidities, and surgeons' antibiotic-loaded cement usage patterns on revision rate, and (3) compared causes of revision (aseptic or septic) between groups. Our study sample was taken from the Canadian Joint Replacement Registry and Canada's Hospital Morbidity Database and included cemented TKAs performed between April 1, 2003, and March 31, 2008, including 20,016 TKAs inserted with non-antibiotic-loaded cement and 16,665 inserted with antibiotic-loaded cement. Chi-square test was used to compare the frequency of early revisions between groups. Cox regression modeling was used to determine whether revision rate would change by age, sex, comorbidities, or use of antibiotic-loaded cement. Similar Cox regression modeling was used to compare cause of revision between groups. Two-year revision rates were similar between the groups treated with non-antibiotic-loaded cement and antibiotic-loaded cement (1.40% versus 1.51%, p = 0.41). When controlling for age, sex, comorbidities, diabetes, and surgeons' antibiotic-loaded cement usage patterns, the revision risk likewise was similar between groups. Revision rates for infection were similar between groups; however, there were more revisions for aseptic loosening in the group treated with non-antibiotic-loaded cement (p = 0.02). The use of antibiotic-loaded cement in TKAs performed for osteoarthritis has no clinically significant effect on reducing revision within 2 years in patients who received perioperative antibiotics. Longer followup and confirmation of these findings with other national registries are warranted.

  15. Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw

    PubMed Central

    Gupta, Rakesh Kumar; Gupta, Vinay; Gupta, Navdeep

    2012-01-01

    Background: Dynamic hip screw (DHS) has been the standard treatment for stable trochanteric fracture patterns, but complications of lag screw cut out from a superior aspect, due to inadequate bone anchorage, occur frequently in elderly osteoporotic patients. Polymethylmethacrylate (PMMA) has been used as an augmentation tool to facilitate fixation stability in cadaveric femora for biomechanical studies and in pathological fractures. However, there are very few reports on the utilization of PMMA cement to prevent these complications in fresh intertrochanteric fractures. A prospective study was conducted to evaluate the outcome and efficacy of PMMA augmented DHS in elderly osteoporotic patients with intertrochanteric fractures. Materials and Methods: The study included 64 patients (AO type31-A2.1 in eight, A2.2 in 29, A2.3 in 17 patients, and 31-A3.1 in five, A3.2 in three, and A3.3 in two patients) with an average age of 72 years (60 – 94 years) of which 60 were available for final followup. PMMA augmentation of DHS was performed in all cases by injecting PMMA cement into the femoral head with a custommade gun designed by the authors. The clinical outcome was rated as per the Salvati and Wilson scoring system at the time of final followup of one year. Results were graded as excellent (score > 31), good (score 24 – 31), fair (score 16 – 23), and poor (score < 16). Results: Fracture united in all patients and the average time to union was 13.8 weeks (range 12 – 16 weeks). At an average followup of 18 months (range 12 – 24 months), no incidence of varus collapse or superior screw cut out was observed in any of the patients in spite of weightbearing ambulation from the early postoperative period. There was no incidence of avascular necrosis (AVN) or cement penetration into the joint in our series. Most of the patients were able to regain their prefracture mobility status with a mean hip pain score of 8.6. Conclusion: Cement augmentation of DHS appears to be an effective method of preventing osteoporosis related complications of fracture fixation in the trochanteric fractures. The technique used for cement augmentation in the present study is less likely to cause possible complications of cement augmentation like thermal necrosis, cement penetration into the joint, and AVN hip. PMID:23325965

  16. Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty.

    PubMed

    Birnbaum, Klaus; Gutknecht, Norbert

    2010-07-01

    The cement often left in the femur socket during hip joint revision arthroplasty is usually removed by curettage. Another method for removing the cement is to use an ultrasonic system, and yet another alternative may be to use a laser system. The aim of these investigations was to determine the pulse rate and pulse energy of the Er:YAG laser for sufficient cement ablation. We also compared the results obtained using the laser with those obtained using an ultrasonic device or curettage by histological and scanning electron microscopy (SEM) investigation of the border zone between the polymethyl methacrylate (PMMA) and unfixed specimens of femoral bone. Therefore we prepared 30 unfixed human femur stems after hip joint replacement and prepared ten sagittal sections from each femur stem (in total 300 sections). Of these 300 specimens, 180 were treated with the Er:YAG laser, 60 with the ultrasonic system and 60 by curettage. The high pulse energy of 500 mJ and a pulse rate of 4 Hz provided the highest PMMA ablation rate, although the boundary surface between PMMA and femoral bone was not as fine-grained as found in samples treated at 15 Hz and 250 mJ. However, the treatment time for the same cement ablation rate with the latter settings was twice that at 4 Hz and 500 mJ. Compared to the boundary surfaces treated with the ultrasonic device or curettage, the laser-treated samples had a more distinct undifferentiated boundary surface between PMMA and femoral bone. After development of the Er:YAG-laser to provide higher pulse energies, it may in the future be an additional efficient method for the removal of PMMA in revision arthroplasty. The Er:YAG laser should be combined with an endoscopic and a rinsing suction system so that PMMA can be removed from the femoral shaft under direct vision.

  17. Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.

    PubMed

    Koh, Bryan T H; Tan, J H; Ramruttun, Amit Kumarsing; Wang, Wilson

    2015-11-17

    In cemented joint arthroplasty, the handling characteristics (doughing, working, and setting times) of polymethyl methacrylate (PMMA) bone cement is important as it determines the amount of time surgeons have to optimally position an implant. Storage conditions (temperature and humidity) and the time given for PMMA cement to equilibrate to ambient operating theater (OT) temperatures are often unregulated and may lead to inconsistencies in its handling characteristics. This has not been previously studied. Hence, the purpose of this study was to investigate the effect of storage temperatures on the handling characteristics of PMMA cement and the duration of equilibration time needed at each storage temperature to produce consistent and reproducible doughing, setting, and working times. SmartSet® HV cement was stored at three different controlled temperatures: 20 °C (control), 24 °C, and 28 °C for at least 24 h prior to mixing. The cement components were then brought into a room kept at 20 °C and 50 % humidity. Samples were allowed to equilibrate to ambient conditions for 15, 30, 45, and 60 min. The cement components were mixed and the dough time, temperature-versus-time curve (Lutron TM-947SD, Lutron Electronics, Inc., Coopersburg, PA), and setting time were recorded. Analysis was performed using the two-way ANOVA test (IBM SPSS Statistics V.22). At 20 °C (control) storage temperature, the mean setting time was 534 ± 17 s. At 24 °C storage temperature, the mean setting time was 414 ± 6 s (p < 0.001*) with 15 min of equilibration, 446 ± 11 s (p < 0.001*) with 30 min of equilibration, 501 ± 12 s (p < 0.001*) with 45 min of equilibration, and 528 ± 15 (p > 0.05) with 60 min of equilibration. At 28 °C storage temperature, the mean setting time was 381 ± 8 s (p < 0.001*) with 15 min of equilibration, 432 ± 30 s (p < 0.001*) with 30 min of equilibration, 487 ± 9 (p < 0.001*) with 45 min of equilibration, and 520 ± 16 s (p > 0.05) with 60 min of equilibration. This study reflects the extent to which storage temperatures and equilibration times can potentially affect the handling characteristics of PMMA cement. We recommend institutions to have a well-regulated temperature and humidity-controlled facility for storage of bone cements and a protocol to standardize the equilibration time of cements prior to use in the OT to improve consistency and reproducibility of the handling characteristics of PMMA cement.

  18. East Europe Report, Economic and Industrial Affairs, No. 2400.

    DTIC Science & Technology

    1983-05-18

    ducts, such as, for instance, oil, natural gas , coal, steel and cement. The socialist countries participate in large-scale successful joint programs of...which there are not many in international practice. Regarding their impact and significance, the joint construction and integration of natural gas ...separators; —reduced pollution (fallout of flue ashes and concentration of gaseous pol- lutants, particularly SO2 and N0X in ground layers of the

  19. Gentamicin release from commercially-available gentamicin-loaded PMMA bone cements in a prosthesis-related interfacial gap model and their antibacterial efficacy.

    PubMed

    Neut, Daniëlle; Kluin, Otto S; Thompson, Jonathan; van der Mei, Henny C; Busscher, Henk J

    2010-11-10

    Around about 1970, a gentamicin-loaded poly (methylmethacrylate) (PMMA) bone cement brand (Refobacin Palacos R) was introduced to control infection in joint arthroplasties. In 2005, this brand was replaced by two gentamicin-loaded follow-up brands, Refobacin Bone Cement R and Palacos R + G. In addition, another gentamicin-loaded cement brand, SmartSet GHV, was introduced in Europe in 2003. In the present study, we investigated differences in gentamicin release and the antibacterial efficacy of the eluent between these four cement brands. 200 μm-wide gaps were made in samples of each cement and filled with buffer in order to measure the gentamicin release. Release kinetics were related to bone cement powder particle characteristics and wettabilities of the cement surfaces. Gaps were also inoculated with bacteria isolated from infected prostheses for 24 h and their survival determined. Gentamicin release and bacterial survival were statistically analysed using the Student's t-test. All three Palacos variants showed equal burst releases but each of the successor Palacos cements showed significantly higher sustained releases. SmartSet GHV showed a significantly higher burst release, while its sustained release was comparable with original Palacos. A gentamicin-sensitive bacterium did not survive in the high gentamicin concentrations in the interfacial gaps, while a gentamicin-resistant strain did, regardless of the type of cement used. Survival was independent of the level of burst release by the bone cement. Although marketed as the original gentamicin-loaded Palacos cement, orthopaedic surgeons should be aware that the successor cements do not appear to have the same release characteristics as the original one. Overall, high gentamicin concentrations were reached inside our prosthesis-related interfacial gap model. These concentrations may be expected to effectively decontaminate the prosthesis-related interfacial gap directly after implantation, provided that these bacteria are sensitive for gentamicin.

  20. The economics of using prophylactic antibiotic-loaded bone cement in total knee replacement.

    PubMed

    Gutowski, C J; Zmistowski, B M; Clyde, C T; Parvizi, J

    2014-01-01

    The rate of peri-prosthetic infection following total joint replacement continues to rise, and attempts to curb this trend have included the use of antibiotic-loaded bone cement at the time of primary surgery. We have investigated the clinical- and cost-effectiveness of the use of antibiotic-loaded cement for primary total knee replacement (TKR) by comparing the rate of infection in 3048 TKRs performed without loaded cement over a three-year period versus the incidence of infection after 4830 TKRs performed with tobramycin-loaded cement over a later period of time of a similar duration. In order to adjust for confounding factors, the rate of infection in 3347 and 4702 uncemented total hip replacements (THR) performed during the same time periods, respectively, was also examined. There were no significant differences in the characteristics of the patients in the different cohorts. The absolute rate of infection increased when antibiotic-loaded cement was used in TKR. However, this rate of increase was less than the rate of increase in infection following uncemented THR during the same period. If the rise in the rate of infection observed in THR were extrapolated to the TKR cohort, 18 additional cases of infection would have been expected to occur in the cohort receiving antibiotic-loaded cement, compared with the number observed. Depending on the type of antibiotic-loaded cement that is used, its cost in all primary TKRs ranges between USD $2112.72 and USD $112 606.67 per case of infection that is prevented.

  1. Does metaphyseal cement augmentation in fracture management influence the adjacent subchondral bone and joint cartilage?: an in vivo study in sheep stifle joints.

    PubMed

    Goetzen, Michael; Hofmann-Fliri, Ladina; Arens, Daniel; Zeiter, Stephan; Stadelmann, Vincent; Nehrbass, Dirk; Richards, R Geoff; Blauth, Michael

    2015-01-01

    Augmentation of implants with polymethylmethacrylate (PMMA) bone cement in osteoporotic fractures is a promising approach to increase implant purchase. Side effects of PMMA for the metaphyseal bone, particularly for the adjacent subchondral bone plate and joint cartilage, have not yet been studied. The following experimental study investigates whether subchondral PMMA injection compromises the homeostasis of the subchondral bone and/or the joint cartilage.Ten mature sheep were used to simulate subchondral PMMA injection. Follow-ups of 2 (4 animals) and 4 (6 animals) months were chosen to investigate possible cartilage damage and subchondral plate alterations in the knee. Evaluation was completed by means of high-resolution peripheral quantitative computed tomography (HRpQCT) imaging, histopathological osteoarthritis scoring, and determination of glycosaminoglycan content in the joint cartilage. Results were compared with the untreated contralateral knee and statistically analyzed using nonparametric tests.Evaluation of the histological osteoarthritis score revealed no obvious cartilage damage for the treated knee; median histological score after 2 months 0 (range 4), after 4 months 1 (range 5). There was no significant difference when compared with the untreated control site after 2 and 4 months (P = 0.23 and 0.76, respectively). HRpQCT imaging showed no damage to the metaphyseal trabeculae. Glycosaminoglycan measurements of the treated joint cartilage after 4 months revealed no significant difference compared with the untreated cartilage (P = 0.24).The findings of this study support initial clinical observation that PMMA implant augmentation of metaphyseal fractures appears to be a safe procedure for fixation without harming the subchondral bone plate and adjacent joint cartilage.

  2. Assessment of asphalt interlayer designed on jointed concrete.

    DOT National Transportation Integrated Search

    2014-11-01

    Reflective cracking in hot mix asphalt (HMA) overlays has been a common cause of poor pavement performance in Iowa for : many years. Reflective cracks commonly occur in HMA overlays when deteriorated portland cement concrete is paved over with : HMA....

  3. Use of discarded tires in highway construction.

    DOT National Transportation Integrated Search

    1980-01-01

    In August 1978, bituminous surface treatments in which vulcanized rubber was blended with the asphalt cement were placed on two secondary roads by the Sahuaro Petroleum and Asphalt Company and the Whitehurst Paving Company. The work was jointly finan...

  4. Portland cement concrete (PCC) partial-depth spall repair

    DOT National Transportation Integrated Search

    1999-11-01

    The primary aim of the partial-depth spall repair study was to determine the most effective and economical materials and procedures for placing quality, long-lasting partial-depth patches in jointed concrete pavements. A secondary objective of the st...

  5. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    PubMed Central

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  6. Osteoconductive Amine-Functionalized Graphene-Poly(methyl methacrylate) Bone Cement Composite with Controlled Exothermic Polymerization.

    PubMed

    Sharma, Rakesh; Kapusetti, Govinda; Bhong, Sayali Yashwant; Roy, Partha; Singh, Santosh Kumar; Singh, Shikha; Balavigneswaran, Chelladurai Karthikeyan; Mahato, Kaushal Kumar; Ray, Biswajit; Maiti, Pralay; Misra, Nira

    2017-09-20

    Bone cement has found extensive usage in joint arthroplasty over the last 50 years; still, the development of bone cement with essential properties such as high fatigue resistance, lower exothermic temperature, and bioactivity has been an unsolved problem. In our present work, we have addressed all of the mentioned shortcomings of bone cement by reinforcing it with graphene (GR), graphene oxide (GO), and surface-modified amino graphene (AG) fillers. These nanocomposites have shown hypsochromic shifts, suggesting strong interactions between the filler material and the polymer matrix. AG-based nanohybrids have shown greater osteointegration and lower cytotoxicity compared to other nanohybrids as well as pristine bone cement. They have also reduced oxidative stress on cells, resulting in calcification within 20 days of the implantation of nanohybrids into the rabbits. They have significantly reduced the exothermic curing temperature to body temperature and increased the setting time to facilitate practitioners, suggesting that reaction temperature and settling time can be dynamically controlled by varying the concentration of the filler. Thermal stability and enhanced mechanical properties have been achieved in nanohybrids vis-à-vis pure bone cement. Thus, this newly developed nanocomposite can create natural bonding with bone tissues for improved bioactivity, longer sustainability, and better strength in the prosthesis.

  7. Rehabilitation in children with juvenile chronic arthritis.

    PubMed

    Häfner, R; Truckenbrodt, H; Spamer, M

    1998-05-01

    Chronic childhood arthritis impairs joint function and may result in severe physical handicap. Joint pain and inflammation trigger a vicious cycle that often ends in joint damage and fixed deformities. A comprehensive rehabilitation programme must start early to restore loss of function and prevent permanent handicap. It is dominated by a physiotherapeutic regimen consisting of pain relief, movement expansion, training of muscular coordination and finally re-integration of a physiological movement pattern. The approaches of occupational therapy become integrated into the treatment programme, concentrating on joint protection and self-care training. Additional aids support the aim of joint restoration. They include individual splinting, adapted footwear and walking aids. Depending on the child's age and developmental status different aspects of rehabilitation dominate. Small children need adequate mobility to promote their psychosocial development. In later years integration into school life and the peer group becomes important. Adolescents require help for an adequate vocational training and self-care support. Last but not least, parental education and integration of the whole family into the rehabilitation programme markedly improve the patient's prognosis.

  8. Bone cement: how effective is it at restoring hearing in isolated incudostapedial erosion?

    PubMed

    Watson, G J; Narayan, S

    2014-08-01

    To determine the effectiveness of biocements in rebridging isolated incudostapedial erosion. A review of the use of biocements for isolated incudostapedial joint erosion was performed on publications from 1998 to 2012 available from Medline, Embase and Pubmed. Inclusion criteria were papers published in English, case series or comparative studies with more than 10 patients, isolated incudostapedial erosion through chronic ear disease, minimal air-bone gap less than 20 dB (or air-bone gap less than 10 dB) and follow up for at least one year. In 108 patients, rebridging ossiculoplasty was performed using hydroxyapatite cement. Closure of air-bone gaps less than 20 dB and less than 10 dB was achieved in 80-94.4 per cent and 29-75 per cent, respectively. Glass ionomer cement was used in 318 patients. Closure of air-bone gaps less than 20 dB and less than 10 dB was achieved in 74-94 per cent and 40-76 per cent, respectively. Biocements can be successfully used to close isolated incudostapedial erosions. Larger comparative prospective studies documenting the length of eroded incus and types of reformation of the incudostapedial joint, with standardised reporting, are needed in the future.

  9. An Approach to the Internationalisation of the Curriculum: Sino-British Joint Efforts for Three Online Courses

    ERIC Educational Resources Information Center

    Yawan, Li; Ying, Li

    2011-01-01

    With a view to facilitating good practice and enhancing further exchanges and collaboration with the Open University UK, the Open University of China initiated a joint programme of training to offer online tutors and academic management staff three courses: Student Support, Tutoring On-line, and Course Design. The programme brought in not only a…

  10. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a snap-fit acetabular component made of an alloy, such as cobalt-chromium-molybdenum, and ultra-high...

  11. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a snap-fit acetabular component made of an alloy, such as cobalt-chromium-molybdenum, and ultra-high...

  12. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a snap-fit acetabular component made of an alloy, such as cobalt-chromium-molybdenum, and ultra-high...

  13. Measuring interdisciplinary research and education outcomes in the Vienna Doctoral Programme on Water Resource Systems

    NASA Astrophysics Data System (ADS)

    Carr, Gemma; Loucks, Daniel Pete; Blaschke, Alfred Paul; Bucher, Christian; Farnleitner, Andreas; Fürnkranz-Prskawetz, Alexia; Parajka, Juraj; Pfeifer, Norbert; Rechberger, Helmut; Wagner, Wolfgang; Zessner, Matthias; Blöschl, Günter

    2015-04-01

    The interdisciplinary postgraduate research and education programme - the Vienna Doctoral Programme on Water Resource Systems - was initiated in 2009. To date, 35 research students, three post-docs and ten faculty members have been engaged in the Programme, from ten research fields (aquatic microbiology, hydrology, hydro-climatology, hydro-geology, mathematical economics, photogrammetry, remote sensing, resource management, structural mechanics, and water quality). The Programme aims to develop research students with the capacity to work across the disciplines, to conduct cutting edge research and foster an international perspective. To do this, a variety of mechanisms are adopted that include research cluster groups, joint study sites, joint supervision, a basic study programme and a research semester abroad. The Programme offers a unique case study to explore if and how these mechanisms lead to research and education outcomes. Outcomes are grouped according to whether they are tangible (publications with co-authors from more than one research field, analysis of graduate profiles and career destinations) or non-tangible (interaction between researchers, networks and trust). A mixed methods approach that includes bibliometric analysis combined with interviews with students is applied. Bibliometric analysis shows that as the Programme has evolved the amount of multi-disciplinary work has increased (32% of the 203 full papers produced by the programme's researchers have authors from more than one research field). Network analysis to explore which research fields collaborate most frequently show that hydrology plays a significant role and has collaborated with seven of the ten research fields. Hydrology researchers seem to interact the most strongly with other research fields as they contribute understanding on water system processes. Network analysis to explore which individuals collaborate shows that much joint work takes place through the five research cluster groups (water resource management, land-surface processes, Hydrological Open Air Laboratory, water and health, modelling and risk). Student interviews highlight that trust between colleagues and supervisors, and the role of spaces for interaction (joint study sites, cluster group meetings, shared offices etc.) are important for joint work. Graduate analysis shows that students develop skills and confidence to work across disciplines through collaborating on their doctoral research. Working collaboratively during the doctorate appears to be strongly correlated with continuing to work in this way after graduation.

  14. Experimental investigations into cryosorption pumping of plasma exhaust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perinic, D.; Mack, A.

    1988-09-01

    Within the framework of the European Fusion Technology Programme the Karlsruhe Nuclear Research Centre has been awarded a contract for the development of cryosorption panels for compound cryopumps of the NEt plasma exhaust pumping system. This task includes the development of a bonding technique for porous sorbent materials with metal substrates and a test programme for development and optimization of cryopanels. A variety of material combinations for sorbent, bonding and substrate were evaluated and listed in a test matrix. Bonding tests involving soldering, cementing and plasma spraying techniques have been carried out.

  15. Percutaneous osteoplasty for the treatment of a painful osteochondral lesion of the talus: a case report and literature review.

    PubMed

    Seo, Sung-Suk; Park, Joo-Yeon; Kim, Hae-Jin; Yoon, Ji-Wook; Park, Sang-Hyun; Kim, Kyung-Hoon

    2012-01-01

    An osteochondral lesion of the talus (OLT) is a lesion involving the talar articular cartilage and its subchondral bone. OLT is a known cause of chronic ankle pain after ankle sprains in the active population. The lesion causes deep ankle pain associated with weight-bearing, impaired function, limited range of motion, stiffness, catching, locking, and swelling. There are 2 common patterns of OLTs. Anterolateral talar dome lesions result from inversion and dorsiflexion injuries of the ankle at the area impacting against the fibula. Posteromedial lesions result from inversion, plantar flexion, and external rotation injuries of the ankle at the area impacting against the tibial ceiling of the ankle joint. Early diagnosis of an OLT is particularly important because the tibiotalar joint is exposed to more compressive load per unit area than any other joint in the body. Failure of diagnosis can lead to the evolution of a small, stable lesion into a larger lesion or an unstable fragment, which can result in chronic pain, joint instability, and premature osteoarthritis. A 43-year-old man, with a history of ankle sprain one year previously, visited our pain clinic for continuous right ankle pain after walking or standing for more than 30 minutes. There was a focal tenderness on the posteromedial area of the right talus. Imaging studies revealed a posteromedial OLT classified as having a geode form according to the FOG (fractures, osteonecroses, geodes) radiological classification and categorized as a stage 2a lesion on magnetic resonance imaging. The patient was scheduled for aspiration and osteoplasty with hydroxyapatite under arthroscopic and fluoroscopic guidance. A 26-gauge needle was inserted to infiltrate local anesthetics into the skin over the cyst and ankle joint. An arthroscope was placed into the joint to approach the OLT. The arthroscopic view showed that there was no connection between the OLT and the cyst of the talus body. A 13-gauge bone biopsy needle was inserted into the cyst, and aspiration was performed. Aspirated fluid from the cyst was originally white and clear; however, it changed to a blood-tinged, reddish color due to mixing with the incisional blood. After aspiration, contrast medium was injected, and the shape of the spread was observed. Bone cement comprising hydroxyapatite was injected to fill the bone defect of the cyst. A 1.5 mL volume of cement was injected into the talus under vigilant fluoroscopic and arthroscopic monitoring to prevent its dissemination into the joint. There was no cement leakage into the vessels or articular space. Postoperative fluoroscopy and computed tomography images showed bone cement filling of the defect. In the present case, arthroscopic and fluoroscopic guidance was used for aspiration of an OLT and for performing percutaneous osteoplasty with hydroxyapatite for one defect; this treatment decreased pain upon weight bearing and enabled a return to work without any restrictions one week after the procedure. The purpose of this report was to highlight the presence of OLT in chronic ankle pain and to review its management strategies.

  16. Cause Analysis on the Void under Slabs of Cement Concrete Pavement

    NASA Astrophysics Data System (ADS)

    Wen, Li; Zhu, Guo Xin; Baozhu

    2017-06-01

    This paper made a systematic analysis on the influence of the construction, environment, water and loads on the void beneath road slabs, and also introduced the formation process of structural void and pumping void, and summarizes the deep reasons for the bottom of the cement concrete pavement. Based on the analysis above, this paper has found out the evolution law of the void under slabs which claimed that the void usually appeared in the slab corners and then the cross joint, resulting void in the four sides with the void area under the front slab larger than the rear one.

  17. Application of individually performed acrylic cement spacers containing 5% of antibiotic in two-stage revision of hip and knee prosthesis due to infection.

    PubMed

    Babiak, Ireneusz

    2012-07-03

    Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.

  18. Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses. A randomized clinical RSA study with 2-year follow-up.

    PubMed

    Hansen, Torben Baek; Stilling, Maiken

    2013-02-01

    Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. In a prospective, parallel-group, randomized patient-blinded clinical trial, we included 32 hands in 28 patients (5 males) with a mean age of 58 (40-77) years and with Eaton stage-2 or -3 osteoarthritis of the trapeziometacarpal joint. Patients were randomized to surgery with a cemented DLC all-polyethylene cup (C) (n = 16) or an uncemented hydroxyapatite-coated chrome-cobalt Elektra screw cup (UC) (n = 16). Uncemented cups were inserted without threading of the bone. Stereoradiographs for evaluation of cup migration (primary effect size) and DASH and pain scores were obtained during 2 years of follow-up. The 2-year total translation (TT) was similar (p = 0.2): 0.24 mm (SD 0.10) for the C (n = 11) and 0.19 mm (SD 0.16) for the UC (n = 11). Variances were similar (p = 0.4). Judged by RSA, 2 UC cups and 1 C cup became loose (TT > 1 mm). Both UC cups were found to be loose at revision. Grip strength, pain, and DASH scores were similar between groups at all measurement points. Early implant fixation and clinical outcome were equally good with both cup designs. This is the first clinical RSA study on trapezium cups, and the method appears to be clinically useful for detection of loose implants.

  19. The combination of ultrasound with antibiotics released from bone cement decreases the viability of planktonic and biofilm bacteria: an in vitro study with clinical strains.

    PubMed

    Ensing, Geert T; Neut, Daniëlle; van Horn, Jim R; van der Mei, Henny C; Busscher, Henk J

    2006-12-01

    Antibiotic-loaded bone cements are used for the permanent fixation of joint prostheses. Antibiotic-loaded cements significantly decrease the incidence of infection. The objective of this study was to investigate whether the viability of bacteria derived from patients with a prosthesis-related infection could be further decreased when antibiotic release from bone cements was combined with application of pulsed ultrasound. Escherichia coli ATCC 10798, Staphylococcus aureus 7323, coagulase-negative staphylococci (CoNS 7368 and CoNS 7391) and Pseudomonas aeruginosa 5148 were grown planktonically in suspension and as a biofilm on three different bone cements: Palacos R without gentamicin as control, gentamicin-loaded Palacos R-G and gentamicin/clindamycin-loaded Copal. The viability of planktonic and biofilm bacteria was measured in the absence and presence of pulsed ultrasound for 40 h. Ultrasound itself did not affect bacterial viability. However, application of pulsed ultrasound in combination with antibiotic release by antibiotic-loaded bone cements yielded a reduction of both planktonic and biofilm bacterial viability compared with antibiotic release without application of ultrasound. This study shows that antibiotic release in combination with ultrasound increases the antimicrobial efficacy further than antibiotic release alone against a variety of clinical isolates. Application of ultrasound in combination with antibiotic release in clinical practice could therefore lead to better prevention or treatment of prosthesis-related infections.

  20. Influence of nucleation seeding on the compressive strength of ordinary Portland cement and alkali activated blast-furnace slag

    DOT National Transportation Integrated Search

    2011-05-10

    The Intelligent Transportation Systems (ITS) Joint Program Office (JPO) of the U.S. Department of Transportation (USDOT) has been collecting the benefits, costs, lessons learned, and deployment status information of ITS. Such information, intended to...

  1. Curl and Warp Analysis of the LTPP SPS-2 Site in Arizona : TechBrief

    DOT National Transportation Integrated Search

    2013-05-01

    Variability in the roughness levels of jointed Portland cement concrete (PCC) pavements can often be observed over short periods of time. This study demonstrated specialized analyses for quantifying the effect of curl and warp on the roughness of joi...

  2. Monitoring and modeling of pavement response and performance task B : New York volume 2, I86 PCC.

    DOT National Transportation Integrated Search

    2012-05-01

    In Cattaraugus County, New York State, Interstate 86 exhibited major distresses, and the jointed reinforced : portland cement concrete pavement (JRCP) and was in need of rehabilitation by 2004. Three experimental sections : were constructed in June 2...

  3. Effects of portland cement particle size on heat of hydration : [summary].

    DOT National Transportation Integrated Search

    2013-12-01

    Generally, when materials are heated (or cooled), : they expand (or contract) to a greater or lesser : extent. Even a material as rock-like as concrete : is susceptible to thermal effects, and expansion : joints are used for this reason: to allow con...

  4. A crossover trial evaluating an educational-behavioural joint protection programme for people with rheumatoid arthritis.

    PubMed

    Hammond, A; Lincoln, N; Sutcliffe, L

    1999-05-01

    Joint protection (JP) is a self-management technique widely taught to people with rheumatoid arthritis (RA). JP education aims to enable people with RA to reduce pain, inflammation, joint stress and reduce risks of deformity through using assistive devices and alternative movement patterns of affected joints to perform everyday activities. Previous studies evaluating JP education methods common in the UK have identified JP adherence is poor. A group education programme was developed using the Health Belief Model and Self-efficacy Theory. Strategies used to maximise JP adherence included goal-setting, contracting, modelling, homework programmes, motor learning theory, recall enhancing methods and mental practice. A crossover trial (n = 35) was conducted. Adherence with JP was measured using an objective observational test (the Joint Protection Behaviour Assessment). Significant improvements in use of JP were recorded at 12 and 24 weeks post-education (P < 0.01). No significant changes in measures of pain, functional disability, grip strength, self-efficacy or helplessness occurred post-education, although this may have been due to the small sample size recruited. In conclusion, JP adherence can be facilitated through the use of educational-behavioural strategies, suggesting this approach should be more widely adopted in clinical practice.

  5. The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Burgo, F J; Mengelle, D E; Ozols, A; Fernandez, C; Autorino, C M

    2016-11-01

    Studies reporting specifically on squeaking in total hip arthroplasty have focused on cementless, and not on hybrid, fixation. We hypothesised that the cement mantle of the femur might have a damping effect on the sound transmitted through the metal stem. The objective of this study was to test the effect of cement on sound propagation along different stem designs and under different fixation conditions. An in vitro model for sound detection, composed of a mechanical suspension structure and a sound-registering electronic assembly, was designed. A pulse of sound in the audible range was propagated along bare stems and stems implanted in cadaveric bone femurs with and without cement. Two stems of different alloy and geometry were compared. The magnitudes of the maximum amplitudes of the bare stem were in the range of 10.8 V to 11.8 V, whereas the amplitudes for the same stems with a cement mantle in a cadaveric bone decreased to 0.3 V to 0.7 V, implying a pulse-attenuation efficiency of greater than 97%. The same magnitude is close to 40% when the comparison is made against stems implanted in cadaveric bone femurs without cement. The in vitro model presented here has shown that the cement had a remarkable effect on sound attenuation and a strong energy absorption in cement mantle and bone. The visco-elastic properties of cement can contribute to the dissipation of vibro-acoustic energy, thus preventing hip prostheses from squeaking. This could explain, at least in part, the lack of reports of squeaking when hybrid fixation is used.Cite this article: F. J. Burgo, D. E. Mengelle, A. Ozols, C. Fernandez, C. M. Autorino. The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty. Bone Joint Res 2016;5:531-537. DOI: 10.1302/2046-3758.511.BJR-2016-0058.R1. © 2016 Burgo et al.

  6. Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces.

    PubMed

    Chen, C Q; Scott, W; Barker, T M

    1999-01-01

    Bonding and loosening mechanisms between bone cement and joint prostheses have not been well identified. In this study, the effects of simulated hip stem surface topography on the interfacial shear strength were examined. Six different surface topographies were used. They were described by several surface characterization parameters that may directly relate to the interfacial bonding strength: average surface roughness R(a), root mean square slope R(Deltaq), correlation length beta, and fluid retention index R(ri). The shear strengths between Palacos E bone cement and stainless steel rods were measured using an Instron materials testing machine. We found that cement can "flow" into the surface microtopography and establish good contact with the metal surface. The results show that the interfacial strength increases monotonically with the increase of R(Deltaq) instead of with R(a). The relationship between interfacial strength and surface parameters shows that a metal stem with an isotropic surface texture, higher R(Deltaq), and greater R(ri) gives a higher interfacial strength. Copyright 1999 John Wiley & Sons, Inc.

  7. Intramedullary rod and cement static spacer construct in chronically infected total knee arthroplasty.

    PubMed

    Kotwal, Suhel Y; Farid, Yasser R; Patil, Suresh S; Alden, Kris J; Finn, Henry A

    2012-02-01

    Two-stage reimplantation, with interval antibiotic-impregnated cement spacer, is the preferred treatment of prosthetic knee joint infections. In medically compromised hosts with prior failed surgeries, the outcomes are poor. Articulating spacers in such patients render the knee unstable; static spacers have risks of dislocation and extensor mechanism injury. We examined 58 infected total knee arthroplasties with extensive bone and soft tissue loss, treated with resection arthroplasty and intramedullary tibiofemoral rod and antibiotic-laden cement spacer. Thirty-seven patients underwent delayed reimplantation. Most patients (83.8%) were free from recurrent infection at mean follow-up of 29.4 months. Reinfection occurred in 16.2%, which required debridement. Twenty-one patients with poor operative risks remained with the spacer for 11.4 months. All patients, during spacer phase, had brace-free ambulation with simulated tibiofemoral fusion, without bone loss or loss of limb length. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. On-line analysis of bulk materials using pulsed neutron interrogation

    NASA Astrophysics Data System (ADS)

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Möller, H.; Bach, P.

    1999-06-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany.

  9. Mitigating Joint Reflective Cracks using Stone Interlayers : Case Study on Louisiana Highway 5, Desoto Parish : Research Project Capsule

    DOT National Transportation Integrated Search

    2017-12-01

    When Portland cement concrete (PCC) pavement reaches an intolerable level of service, it is commonly overlaid with asphaltic concrete (AC) and is referred to as a composite pavement. Even though AC overlays are designed to resist failure mechanisms s...

  10. Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants.

    PubMed

    Nuño, N; Groppetti, R; Senin, N

    2006-11-01

    Design of cemented hip and knee implants, oriented to improve the longevity of artificial joints, is largely based on numerical models. The static coefficient of friction between the implant and the bone cement is necessary to characterize the interface conditions in these models and must be accurately provided. The measurement of this coefficient using a repeatable and reproducible methodology for materials used in total hip arthroplasty is missing from the literature. A micro-topographic surface analysis characterized the surfaces of the specimens used in the experiments. The coefficient of friction between stainless steel and bone cement in dry and wet conditions using bovine serum was determined using a prototype computerized sliding friction tester. The effects of surface roughness (polished versus matt) and of contact pressure on the coefficient of friction have also been investigated. The serum influences little the coefficient of friction for the matt steel surface, where the mechanical interactions due to higher roughness are still the most relevant factor. However, for polished steel surfaces, the restraining effect of proteins plays a very relevant role in increasing the coefficient of friction. When the coefficient of friction is used in finite element analysis, it is used for the debonded stem-cement situation. It can thus be assumed that serum will propagate between the stem and the cement mantle. The authors believe that the use of a static coefficient of friction of 0.3-0.4, measured in the present study, is appropriate in finite element models.

  11. Principles of Antibiotic Prophylaxis in Total Joint Arthroplasty: Current Concepts.

    PubMed

    Bosco, Joseph; Bookman, Jared; Slover, James; Edusei, Emmanuel; Levine, Brett

    2016-01-01

    Infection is a rare, serious complication after total joint arthroplasty and constitutes a considerable emotional and financial burden for patients, surgeons, and healthcare systems. Prevention of surgical site and periprosthetic joint infections is crucial. This requires knowledge of the microorganisms that commonly cause these infections, including Staphylococcus species. Selection of the appropriate antibiotic regimen to treat infection remains controversial, but cefazolin and cefuroxime are the most commonly recommended antibiotics for prophylaxis. Appropriate timing of administration before surgery, with redosing performed as needed, can help to ensure optimal antibiotic concentration during surgery. Given the increasing evidence that S aureus colonization is a risk factor for periprosthetic joint infection, an exploration of the potential benefits of preoperative S aureus carrier screening and decolonization protocols is warranted. The use of antibiotic-loaded bone cement in primary total joint arthroplasty and antibiotic powder at wound closure are other controversial topics that require additional research.

  12. List of Organizing Committees and Conference Programme

    NASA Astrophysics Data System (ADS)

    2012-03-01

    Organizers Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH Romanian Neutron Scattering Society Sponsors Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH Comenius University in Bratislava, Slovakia Institute of Macromolecular Chemistry AS CR, Czech Republic Programme Committee Valentin Gordely (chairman)Joint Institute for Nuclear Research, Russia Heinrich StuhrmannGermany Jose TeixeiraLaboratoire Leon Brillouin, France Pavel ApelJoint Institute for Nuclear Research, Russia Pavol BalgavyComenius University in Bratislava, Slovakia Alexander BelushkinJoint Institute for Nuclear Research, Russia Georg BueldtInstitute of Structural Biology and Biophysics (ISB), Germany Leonid BulavinTaras Shevchenko National University of Kyiv, Ukraine Emil BurzoBabes-Bolyai University, Romania Vadim CherezovThe Scripps Research Institute, Department of Molecular Biology, USA Ion IonitaRomanian Society of Neutron Scattering, Romania Alexei KhokhlovMoscow State University, Russia Aziz MuzafarovInstitute of Synthetic Polymeric Materials, Russian Academy of Sciences, Russia Alexander OzerinInstitute of Synthetic Polymeric Materials, Russian Academy of Sciences, Russia Gerard PepyResearch Institute for Solid State Physics and Optics, Hungary Josef PlestilInstitute of Macromolecular Chemistry CAS, Czech Republic Aurel RadulescuJuelich Centre for Neutron Science JCNS, Germany Maria BalasoiuJoint Institute for Nuclear Research, Russia Alexander KuklinJoint Institute for Nuclear Research, Russia Local Organizing Committee Alexander Kuklin - Chairman Maria Balasoiu - Co-chairman Tatiana Murugova - Secretary Natalia Malysheva Natalia Dokalenko Julia Gorshkova Andrey Rogachev Oleksandr Ivankov Dmitry Soloviev Lilia Anghel Erhan Raul The PDF also contains the Conference Programme.

  13. A new joint training programme in infectious diseases and medical microbiology.

    PubMed

    Cohen, J; Roberts, C

    2000-01-01

    The increasing overlap between the disciplines of medical microbiology and infectious diseases prompted the Joint Royal Colleges Committee on Infection and Tropical Medicine to set up a working party to examine how trainees could obtain certification in both subjects. Following widespread consultations, a scheme was developed that entails six years of training and leads to the award of CCSTs in both microbiology and infectious diseases. Both Royal Colleges and the Specialist Training Authority have approved the scheme. Joint training will be demanding and will not be suitable for everyone; it represents an alternative approach to training in the infection disciplines that will run alongside the existing monospecialty training programmes.

  14. Inducible displacement of cemented tibial components ten years after total knee arthroplasty.

    PubMed

    Lam Tin Cheung, K; Lanting, B A; McCalden, R W; Yuan, X; MacDonald, S J; Naudie, D D; Teeter, M G

    2018-02-01

    The aim of this study was to evaluate the long-term inducible displacement of cemented tibial components ten years after total knee arthroplasty (TKA). A total of 15 patients from a previously reported prospective trial of fixation using radiostereometric analysis (RSA) were examined at a mean of 11 years (10 to 11) postoperatively. Longitudinal supine RSA examinations were acquired at one week, one year, and two years postoperatively and at final follow-up. Weight-bearing RSA examinations were also undertaken with the operated lower limb in neutral and in maximum internal rotation positions. Maximum total point motion (MTPM) was calculated for the longitudinal and inducible displacement examinations (supine versus standing, standing versus internal rotation, and supine versus standing with internal rotation). All patients showed some inducible displacement. Two patients with radiolucent lines had greater mean standing-supine MTPM displacement (1.35; sd 0.38) compared with the remaining patients (0.68; sd 0.36). These two patients also had a greater mean longitudinal MTPM at ten years (0.64; sd 0.50) compared with the remaining patients (0.39; sd 0.13 mm). Small inducible displacements in well-fixed cemented tibial components were seen ten years postoperatively, of a similar magnitude to that which has been reported for well-fixed components one to two years postoperatively. Greater displacements were found in components with radiolucent lines. Cite this article: Bone Joint J 2018;100-B:170-5. ©2018 The British Editorial Society of Bone & Joint Surgery.

  15. Developing design methods of concrete mix with microsilica additives for road construction

    NASA Astrophysics Data System (ADS)

    Dmitrienko, Vladimir; Shrivel, Igor; Kokunko, Irina; Pashkova, Olga

    2017-10-01

    Based on the laboratory test results, regression equations having standard cone and concrete strength, to determine the available amount of cement, water and microsilica were obtained. The joint solution of these equations allowed the researchers to develop the algorithm of designing heavy concrete compositions with microsilica additives for road construction.

  16. Microbial resistance related to antibiotic-loaded bone cement: a historical review.

    PubMed

    Walker, Lucy C; Baker, Paul; Holleyman, Richard; Deehan, David

    2017-12-01

    The use of antibiotic-loaded bone cement (ALBC) has a range of indications for use in orthopaedics. It has the advantage of delivering high loads of antibiotics to a targeted site, thereby avoiding the side effects associated with systemic administration. However, there is concern that the use of ALBC may precipitate the development of antibiotic-resistant bacteria. This review focuses on (1) the published research using both animal and human models examining the association between ALBC and the induction of microbial resistance (2) the mechanisms by which antimicrobial resistance develop (3) the research pertaining to specific classes of antibiotics commonly used in orthopaedic practice (4) the recent developments in calcium sulphate beads, nanoparticles and chitosan, as alternative antimicrobial treatments for periprosthetic joint infections. The literature for and against a link between ALBC and the development of microbiological resistance is reviewed and presented. It is concluded that further research is needed to develop a defined set of indications for the use of ALBC in the management of periprosthetic joint infection. In addition, further research into alternative antimicrobial therapies in this area should be encouraged.

  17. Publications - GMC 369 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 369 Publication Details Title: Pyramid Project: Aleut-Quintana-Duval Joint Venture Report on Project: Aleut-Quintana-Duval Joint Venture Report on 1975 Drill Programme: Alaska Division of Geological

  18. "Me Amo Leer" Reading Experiences in a Central Illinois Summer Migrant Education Programme

    ERIC Educational Resources Information Center

    Pavri, Shireen; Bentz, Johnell; Bradley, Janetta Fleming; Corso, Laurie

    2005-01-01

    This paper describes the assessment and instructional strategies used in a migrant education programme that had positive academic outcomes for a group of 11 eight-to-12-year-old Spanish/English-speaking students of Mexican descent. Students attended this four-week summer programme, jointly sponsored by the University of Illinois and the local…

  19. Patients with Revision Modern Megaprostheses of the Distal Femur Have Improved Disease-Specific and Health-Related Outcomes Compared to Those with Primary Replacements.

    PubMed

    Heyberger, Clémence; Auberger, Guillaume; Babinet, Antoine; Anract, Philippe; Biau, David J

    2017-12-21

    We asked whether there would be any difference between primary and revision modern cemented fixed hinge megaprosthesis of the distal femur in function and activity-related outcomes following treatment of a bone tumor. An identical custom-made fixed hinge cemented megaprosthesis with a hydroxyapatite collar was used in all cases. The main outcomes were joint-specific function, disease-specific activity, and health-related quality of life. Implant survival was also evaluated. Patients in the revision group performed slightly better than patients in the primary group on disease-specific (Toronto Extremity Salvage Score, p  = 0.033; Musculoskeletal Tumor Society, p  = 0.072) and health-related outcomes (Short Form 36 [SF-36] physical component, p  = 0.085; SF-36 mental component, p  = 0.069) but not on joint-specific outcomes (Knee Society Score, p  = 0.94). The cumulative probabilities of revision for any reason were 14.5% (7-25%) at 5 years with no statistically significant difference between primary and revision procedures ( p  = 0.77). In conclusion, patients undergoing a revision have similar joint-specific functional outcome but improved disease-specific and health-related outcomes. Implant survival are similar between groups. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Cemented or cementless humeral fixation in reverse total shoulder arthroplasty? a systematic review.

    PubMed

    Phadnis, J; Huang, T; Watts, A; Krishnan, J; Bain, G I

    2016-01-01

    To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. ©2016 The British Editorial Society of Bone & Joint Surgery.

  1. Airborne and Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS)

    DTIC Science & Technology

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-421 Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) As of FY 2017...Information Program Name Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) DoD Component Army Responsible Office References SAR...UNCLASSIFIED 5 Mission and Description Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) products are software programmable

  2. National Dam Safety Program. Tivoli Lake Dam (Inventory Number N.Y. 52), Hudson River Basin, Rockland County, New York. Phase I Inspection Report,

    DTIC Science & Technology

    1980-09-30

    3/8" pea gravel., Apply I coat of Uniweld or Sika Dur Hi-Mod over old concrete to insure the proper bonding. V 2. Repeat process one for section over...Bay 1. 3. Chip out cracked concrete along Bays 7 and 8, apply one coat Colma Joint Primer and fill with Colma Joint Sealer (As manufactured by Sika ) 4...deck. Cracked concrete should be repaired with Sika Dur. Hi-Mod and application of low slump nonshrink grout’ made with antihydro cement

  3. High velocity penetration into fibre-reinforced concrete materials - protection of buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, W.F.; Watson, A.J.; Armstrong, P.J.

    1983-05-01

    Fibre reinforced concrete suitable for spraying onto existing structures is being examined to assess its resistance to penetration by 7.62mm diameter armour piercing projectiles. A major test programme is being carried out to examine the influence of aggregate type and fibre type. For each aggregate/fibre combination a statistical method is being used to plan test series which will lead to optimization of the concrete in terms of water/cement ratio, fibre content and aggregate/cement ratio. The minimum thickness of optimized concretes to resist penetration by the projectile and minimise spall and scabbing, will be determined. The mechanics of the impact andmore » penetration event are being studied and a possible method of deflecting the projectile within the concrete is suggested.« less

  4. Estimation of the amount of asbestos-cement roofing in Poland.

    PubMed

    Wilk, Ewa; Krówczyńska, Małgorzata; Pabjanek, Piotr; Mędrzycki, Piotr

    2017-05-01

    The unique set of physical and chemical properties has led to many industrial applications of asbestos worldwide; one of them was roof covering. Asbestos is harmful to human health, and therefore its use was legally forbidden. Since in Poland there is no adequate data on the amount of asbestos-cement roofing, the objective of this study was to estimate its quantity on the basis of physical inventory taking with the use of aerial imagery, and the application of selected statistical features. Data pre-processing and analysis was executed in R Statistical Environment v. 3.1.0. Best random forest models were computed; model explaining 72.9% of the variance was subsequently used to prepare the prediction map of the amount of asbestos-cement roofing in Poland. Variables defining the number of farms, number and age of buildings, and regional differences were crucial for the analysis. The total amount of asbestos roofing in Poland was estimated at 738,068,000 m 2 (8.2m t). It is crucial for the landfill development programme, financial resources distribution, and application of monitoring policies.

  5. Principles of Antibiotic Prophylaxis in Total Joint Arthroplasty: Current Concepts.

    PubMed

    Bosco, Joseph A; Bookman, Jared; Slover, James; Edusei, Emmanuel; Levine, Brett

    2015-08-01

    Infection is a rare, serious complication following total joint arthroplasty and constitutes a considerable emotional and financial burden for patients, surgeons, and healthcare systems. Prevention of surgical site and periprosthetic joint infections is crucial. This requires knowledge of the microorganisms that commonly cause these infections, including Staphylococcus species. Selection of the appropriate antibiotic regimen to treat infection remains controversial, but cefazolin and cefuroxime are the most commonly recommended antibiotics for prophylaxis. Appropriate timing of administration before surgery, with redosing performed as needed, can help to ensure optimal antibiotic concentration during surgery. Given the increasing evidence that S aureus colonization is a risk factor for periprosthetic joint infection, an exploration of the potential benefits of preoperative S aureus carrier screening and decolonization protocols is warranted. The use of antibiotic-loaded bone cement in primary total joint arthroplasty and antibiotic powder at wound closure are other controversial topics that require additional research. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  6. Dragon 2 Programme Achievements and Cooperation

    NASA Astrophysics Data System (ADS)

    Desnos, Yves-Louis; Li, Zengyuan; Zmuda, Andy; Gao, Zhihai

    2013-01-01

    The cooperation between ESA and National Remote Sensing Center of China (NRSCC) / Ministry of Science and Technology of China (MOST) in the development of Earth Observation (EO) applications started 17 years ago. In 2004, a new phase in cooperation began with the start of the Dragon Programme which focused on science and application using ESA ERS and Envisat satellite data. The programme was completed in 2008. Following on, the cooperation took on greater momentum with the start of a four-year EO science and exploitation programme called “Dragon 2”. The programme formally closed in June at the 2012 Beijing Symposium. The programme brought together joint Sino-European teams to investigate land, ocean and atmospheric applications in P.R. China using EO data from ESA, Third Party Mission (TPM) and Chinese satellites. The teams were led by principal EO scientists. Young European and Chinese scientists were also engaged on the projects. Advanced training courses in land, ocean and atmospheric applications were held in each year of the programme in China. Altogether, two courses on land, one course on atmospheric applications and one course on oceanographic applications were held. Here-in provided is an overview of the achievements, cooperation, reporting and training activities at the completion of the programme. The Sino-European teams have delivered world-class scientific results across a wide range of disciplines. The programme provided a platform for the joint exploitation of ESA, TPM and Chinese EO data from optical, thermal and microwave sensors for geo-science application and development in China.

  7. Recommendations for Filler Material Composition and Delivery Method for Bench-Scale Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardin, Ernest; Brady, Patrick Vane

    This report supplements Joint Workplan on Filler Investigations for DPCs (SNL 2017) providing new and some corrected information for use in planning Phase 1 laboratory testing of slurry cements as possible DPC fillers. The scope description is to "Describe a complete laboratory testing program for filler composition, delivery, emplacement in surrogate canisters, and post-test examination. To the extent possible specify filler material and equipment sources." This report includes results from an independent expert review (Dr. Arun Wagh, retired from Argonne National Laboratory and contracted by Sandia) that helped to narrow the range of cement types for consideration, and to providemore » further guidance on mix variations to optimize injectability, durability, and other aspects of filler performance.« less

  8. Assessment of the Breakaway Torque at the Posterior Pelvic Ring in Human Cadavers.

    PubMed

    Bastian, Johannes Dominik; Bergmann, Mathias; Schwyn, Ronald; Keel, Marius Johann Baptist; Benneker, Lorin Michael

    2015-01-01

    To enhance the diminished screw purchase in cancellous, osteoporotic bone following the fixation of posterior pelvic ring injuries by iliosacral screws an increased bone-implant contact area using modificated screws, techniques or bone cement may become necessary. The aim of the study was to identify sites within the pathway of iliosacral screws requiring modifications of the local bone or the design of instrumentations placed at this site. The breakaway torque was measured mechanically at the iliosacral joint ("ISJ"), the sacral lateral mass ("SLM") and the center of the S1 ("CS1"), at a superior and an inferior site under fluoroscopic control on five human cadaveric specimens (3 female; mean age 87 years, range: 76-99) using the DensiProbe™Spine device. The measured median (range) breakaway torque was 0.63 Nm (0.31-2.52) at the "iliosacral joint", 0.14 Nm (0.05-1.22) at the "sacral lateral mass", 0.57 Nm (0.05-1.42) at the "S1 center." The "sacral lateral mass" breakaway torque was lower than compared to that at the "iliosacral joint" (p < .001) or "S1 center" (p < .001). The median (range) breakaway torque measured at all superior measurement points was 0.52 Nm (0.10-2.52), and 0.48 Nm (0.05-1.18) at all inferior sites. The observed difference was statistically significant (p < .05). The lateral mass of the sacrum provides the lowest bone quality for implant anchorage. Iliosacral screws should be placed as superior as safely possible, should bridge the iliosacral joint and may allow for cement application at the lateral mass of the sacrum through perforations.

  9. Farmers Functional Literacy Programme.

    ERIC Educational Resources Information Center

    Ministry of Education and Social Welfare, New Delhi (India).

    The Farmers Training and Functional Literacy Programme, initiated by the government of India in 1968, was an effort to translate into practice the concept of linking education (not only vocational training) to development, particularly for increasing production. The project, a joint enterprise of three government ministries, provides participating…

  10. Origin of minerals in joint and cleat systems of the Pottsville Formation, Black Warrior basin, Alabama: Implications for coalbed methane generation and production

    USGS Publications Warehouse

    Pitman, Janet K.; Pashin, J.C.; Hatch, J.R.; Goldhaber, M.B.

    2003-01-01

    Coalbed methane is produced from naturally fractured strata in the lower Pennsylvanian Pottsville Formation in the eastern part of the Black Warrior basin, Alabama. Major fracture systems include orthogonal fractures, which consist of systematic joints in siliciclastic strata and face cleats in coal that strike northeast throughout the basin. Calcite and minor amounts of pyrite commonly fill joints in sandstone and shale and, less commonly, cleats in coal. Joint-fill calcite postdates most pyrite and is a weakly ferroan, coarse-crystalline variety that formed during a period of uplift and erosion late in the burial history. Pyrite forms fine to coarse euhedral crystals that line jointwalls or are complexly intergrown with calcite. Stable-isotope data reveal large variations in the carbon isotope composition of joint- and cleat-fill calcite (-10.3 to +24.3 per mil Peedee belemnite [PDB]) but only a relatively narrow range in the oxygen-isotope composition of this calcite (-16.2 to -4.1 per mil PDB). Negative carbon values can be attributed to (super 13) C-depleted CO (sub 2) derived from the oxidation of organic matter, and moderately to highly positive carbon values can be attributed to bacterial methanogenesis. Assuming crystallization temperatures of 20-50 degrees C, most joint- and cleat-fill calcite precipitated from fluids with delta (super 18) O ratios ranging from about -11 to +2 per mil standard mean ocean water (SMOW). Uplift and unroofing since the Mesozoic led to meteoric recharge of Pottsville strata and development of freshwater plumes that were fed by meteoric recharge along the structurally upturned, southeastern margin of the basin. Influxes of fresh water into the basin via faults and coalbeds facilitated late-stage bacterial methanogenesis, which accounts for the high gas content in coal and the carbonate cementation of joints and cleats. Diagenetic and epigenetic minerals can affect the transmissivity and storage capacity of joints and cleats, and they appear to contribute significantly to interwell heterogeneity in the Pottsville Formation. In highly productive coalbed methane fields, joint- and cleat-fill calcite have strongly positive delta (super 13) C values, whereas calcite fill has lower delta (super 13) C values in fields that are shut in or abandoned. Petrographic analysis and stable-isotope geochemistry of joint- and cleat-fill cements provide insight into coalbed methane reservoir quality and the nature and extent of reservoir compartmentalization, which are important factors governing methane production.

  11. Development Problems With Component Construction. Proceedings of Conference of the Building Research Institute, Division of Engineering and Industrial Research (Fall 1959).

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    Publication of conference papers includes--(1) an overview of the ceiling system complex by a lighting manufacturer, (2) review of problems influencing the development of roofing systems, (3) description of cooperative research within the cement industry, and (4) description of joint research development of structural ceramic panels. Included…

  12. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  13. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  14. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...: Articulating Surfaces Made of Metal, Ceramic and Plastic Materials,” and (viii) ISO 9001:1994 “Quality Systems... of Porous Metal Coatings,” (v) F 1108-97 “Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal Coatings,” (vii) F 1537-94...

  15. Microencapsulation of rifampicin: A technique to preserve the mechanical properties of bone cement.

    PubMed

    Sanz-Ruiz, Pablo; Carbó-Laso, Esther; Del Real-Romero, Juan Carlos; Arán-Ais, Francisca; Ballesteros-Iglesias, Yolanda; Paz-Jiménez, Eva; Sánchez-Navarro, Magdalena; Pérez-Limiñana, María Ángeles; Vaquero-Martín, Javier

    2018-01-01

    Two-stage exchange with antibiotic-loaded bone cement spacers remains the gold standard for chronic periprosthetic joint infection (PJI). Rifampicin is highly efficient on stationary-phase staphylococci in biofilm; however, its addition to PMMA to manufacture spacers prevents polymerization and reduces mechanical properties. Isolation of rifampicin during polymerization by microencapsulation could allow manufacturing rifampicin-loaded bone cement maintaining elution and mechanical properties. Microcapsules of rifampicin with alginate, polyhydroxybutyratehydroxyvalerate (PHBV), ethylcellulose and stearic acid (SA) were synthesized. Alginate and PHBV microcapsules were added to bone cement and elution, compression, bending, hardness, setting time and microbiological tests were performed. Repeated measures ANOVA and Bonferroni post-hoc test were performed, considering a p < 0.05 as statistical significance. Bone cement specimens containing alginate microcapsules eluted more rifampicin than PHBV microcapsules or non-encapsulated rifampicin over time (p < 0.012). Microencapsulation of rifampicin allowed PMMA to preserve mechanical properties in compression and bending tests. Cement with alginate microcapsules showed similar behavior in hardness tests to control cement over the study period (73 ± 1.68H D ). PMMA with alginate microcapsules exhibited the largest zones of inhibition in microbiological tests. Statistically significant differences in mean diameters of zones of inhibition between PMMA loaded with alginate-rifampicin (p = 0.0001) and alginate-PHBV microcapsules (p = 0.0001) were detected. Rifampicin microencapsulation with alginate is the best choice to introduce rifampicin in PMMA preserving mechanical properties, setting time, elution, and antimicrobial properties. The main applicability of this study is the opportunity for obtaining rifampicin-loaded PMMA by microencapsulation of rifampicin in alginate microparticles, achieving high doses of rifampicin in infected tissues, increasing the successful of PJI treatment. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:459-466, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Lessons learnt on implementing an interdisciplinary doctoral programme in water sciences

    NASA Astrophysics Data System (ADS)

    Carr, Gemma; Loucks, Daniel Pete; Blaschke, Alfred Paul; Bucher, Christian; Farnleitner, Andreas; Fürnkranz-Prskawetz, Alexia; Parajka, Juraj; Pfeifer, Norbert; Rechberger, Helmut; Wagner, Wolfgang; Zessner, Matthias; Blöschl, Günter

    2015-04-01

    Using the Vienna Doctoral Programme on Water Resource Systems as a case study, this work describes how the characteristics of the programme can be evaluated to identify which process features are important for developing interdisciplinary research at the doctoral level. The Programme has been running since 2009, and to date has engaged 35 research students, three post-docs and ten faculty members from ten research fields (aquatic microbiology, hydrology, hydro-climatology, hydro-geology, mathematical economics, photogrammetry, remote sensing, resource management, structural mechanics, and water quality). Collaborative, multi-disciplinary research is encouraged and supported through various mechanisms - shared offices, study programme, research cluster groups that hold regular meetings, joint study sites, annual and six-month symposia that bring all members of the programme together, seminar series, joint supervision, and social events. Interviews were conducted with 12 students and recent graduates to explore individual experiences of doing interdisciplinary research within the Programme, and to identify which mechanisms are perceived to be of the greatest benefit for collaborative work. Analysis revealed four important process features. Firstly, students noted that joint supervision and supervisors who are motivated to collaborate are essential for multi-disciplinary collaborative work. Secondly, interviewees described that they work with the people they sit close to or see most regularly. Physical places for collaboration between different discipline researchers such as shared offices and shared study sites are therefore important. Thirdly, the costs and benefits to doing interdisciplinary work were highlighted. Students make a trade-off when deciding if their time investment to develop their understanding of a new research field will support them in addressing their research question. The personal characteristics of the researcher seem to be particularly relevant to this decision making process and need to be considered during student selection. Finally, communication skills are critical. Students noted that they need to be able to understand what each other are doing in order to work together and the symposia and research cluster meetings are good places for developing these skills.

  17. Integration of microbiology and infectious disease teaching courses in an interdisciplinary training programme (Master level) centred on the 'One world, one health' WHO concept.

    PubMed

    Eveillard, Matthieu; Ruvoen, Nathalie; Lepelletier, Didier; Fradet, Stéphanie; Couvreur, Sébastien; Krempf, Michel; Magras, Catherine

    2016-05-01

    This report describes the integration of the microbiology and infectious diseases teaching courses in an international Master's level interdisciplinary programme based on the 'One world, one health' WHO concept, and reports the students and teachers' evaluation related to their feelings of about this innovative programme. The integration was evaluated by recording the positioning of these two topics in the five teaching units constituting the programme, and by identifying their contribution in the interactions between the different teaching units. The satisfaction of students was assessed by a quantitative survey, whereas the feelings of students and teachers were assessed by interviews. The study demonstrated that microbiology and infectious diseases were widely involved in interactions between the teaching units, constituting a kind of cement for the programme. The students assigned a mean score of 3.7 to the topics dealing with microbiology and infectious diseases. According to the qualitative data, students and teachers considered that the interdisciplinary approach provided new insights but reported problems of communication, probably inherent to the multiculturalism of the class. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. The effects of a strength and neuromuscular exercise programme for the lower extremity on knee load, pain and function in obese children and adolescents: study protocol for a randomised controlled trial.

    PubMed

    Horsak, Brian; Artner, David; Baca, Arnold; Pobatschnig, Barbara; Greber-Platzer, Susanne; Nehrer, Stefan; Wondrasch, Barbara

    2015-12-23

    Childhood obesity is one of the most critical and accelerating health challenges throughout the world. It is a major risk factor for developing varus/valgus misalignments of the knee joint. The combination of misalignment at the knee and excess body mass may result in increased joint stresses and damage to articular cartilage. A training programme, which aims at developing a more neutral alignment of the trunk and lower limbs during movement tasks may be able to reduce knee loading during locomotion. Despite the large number of guidelines for muscle strength training and neuromuscular exercises that exist, most are not specifically designed to target the obese children and adolescent demographic. Therefore, the aim of this study is to evaluate a training programme which combines strength and neuromuscular exercises specifically designed to the needs and limitations of obese children and adolescents and analyse the effects of the training programme from a biomechanical and clinical point of view. A single assessor-blinded, pre-test and post-test randomised controlled trial, with one control and one intervention group will be conducted with 48 boys and girls aged between 10 and 18 years. Intervention group participants will receive a 12-week neuromuscular and quadriceps/hip strength training programme. Three-dimensional (3D) gait analyses during level walking and stair climbing will be performed at baseline and follow-up sessions. The primary outcome parameters for this study will be the overall peak external frontal knee moment and impulse during walking. Secondary outcomes include the subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS), frontal and sagittal kinematics and kinetics for the lower extremities during walking and stair climbing, ratings of change in knee-related well-being, pain and function and adherence to the training programme. In addition, the training programme will be evaulated from a clinical and health status perspective by including the following analyses: cardiopulmonary testing to quantify aerobic fitness effects, anthropometric measures, nutritional status and psychological status to characterise the study sample. The findings will help to determine whether a neuromuscular and strength training exercise programme for the obese children population can reduce joint loading during locomotion, and thereby decrease the possible risk of developing degenerative joint diseases later in adulthood. ClinicalTrials NCT02545764 , Date of registration: 24 September 2015.

  19. Progress and Achievements At the Mid Term Stage of the Dragon 2 Programme

    NASA Astrophysics Data System (ADS)

    Desnos, Yves-Louis; Li, Zhengyuan; Zmuda, Andy; Gao, Zhihai

    2010-10-01

    The cooperation between ESA and National Remote Sensing Center of China (NRSCC) / Ministry Of Science and Technology of China (MOST) in the development of Earth Observation (EO) applications started 15 years ago. In 2004, a new phase in cooperation began with the start of the Dragon Programme which focused on science and application using ESA satellite data. The programme was completed in 2008. Following on, the cooperation took on greater momentum with the start of a four-year EO science and exploitation programme called 'Dragon 2'. This programme brings together joint Sino-European teams to investigate land, ocean and atmospheric applications in P.R. China using data from ESA, Third Party Mission and Chinese Earth Observation satellites. The teams are led by leading EO scientists and young scientists are also engaged on the projects. Advanced training in land, ocean and atmospheric applications is a feature of the programme and after 2 years, two courses on land and one course on atmospheric applications have been successfully held in 2008, 2009 and 2010 in China. Here-in provided is an overview of the results, reporting and training activities at the mid term stage of the programme. The Sino-European teams continue to deliver world-class scientific results across a wide range of disciplines. The programme provides a platform for the joint exploitation of ESA, TPM and Chinese EO data from optical, infrared, thermal and microwave sensors for science and application development.

  20. Effectiveness of a balance training home exercise programme for adults with haemophilia: a pilot study.

    PubMed

    Hill, K; Fearn, M; Williams, S; Mudge, L; Walsh, C; McCarthy, P; Walsh, M; Street, A

    2010-01-01

    Adults with haemophilia and other bleeding disorders often develop lower limb musculoskeletal problems associated with bleeds into joints and muscles, which may affect balance performance and increase likelihood of falling. The aim of this study was to evaluate the effectiveness of an individualized balance and strength home exercise programme on improving balance and related outcomes for adults with haemophilia and other bleeding disorders. Twenty male adults with haemophilia and other bleeding disorders (mean age 39.4 years, 95% CI = 33.7-45.1) were recruited to participate. They underwent a comprehensive clinical and force platform assessment of balance and related measures. Based on assessment findings, the assessing physiotherapist provided an individualized home exercise programme of balance, strengthening and walking exercises. Re-assessment occurred after the 4-month exercise programme. Twelve participants (60%) completed the programme and were re-assessed. There were no safety problems or dropouts associated with the exercise programme aggravating joint status. Although there were no statistically significant changes in any of the measures (adjusted for multiple comparisons), there were improvements of between 5% and 22% on 10 of the 16 measures, with the Neurocom modified Clinical Test of Sensory Interaction on Balance (P = 0.036) and Timed Sit to Stand (P = 0.064) approaching significance. A tailored home exercise programme targeting balance, strengthening and walking is feasible for adults with haemophilia and other bleeding disorders. These results suggest that positive physical outcomes including improved balance and mobility may be achieved with this type of programme.

  1. Progress and Achievements at the Mid Term of the Dragon 3 Programme

    NASA Astrophysics Data System (ADS)

    Desnos, Yves-Louis; Li, Zengyuan; Zmuda, Andy; Gao, Zhihai

    2014-11-01

    The Dragon Programme is a joint undertaking between ESA and the Ministry of Science and Technology (MOST) of China and the National Remote Sensing Center of China (NRSCC). Its purpose is to encourage increased exploitation of ESA and Chinese space resources within China as well as stimulate increased scientific cooperation in the field of Earth Observation (EO) science and applications between China and Europe. Since 2004, this pioneering programme has become a model for scientific and technological cooperation between China and Europe. By successfully encouraging joint research using ESA, Third Party Missions and Chinese EO data across a range of thematic areas, Dragon continues to deliver outstanding scientific results. The programme has successfully completed two phases, Dragon 1 from 2004 to 2008, Dragon 2 from 2008 to 2012. The third phase of Dragon was started in 2012 and will be completed in 2016. The Dragon 3 project teams are led by leading EO scientists and young scientists are also engaged on the projects. Advanced training in land, ocean and atmospheric applications is a feature of the programme and a course on land and one course on ocean applications have been successfully held in 2012 and 2013 in China. Here-in provided is an overview of the results, reporting and training activities at the mid-term stage of the programme.

  2. Investigation of wellbore microannulus permeability under stress via experimental wellbore mock-up and finite element modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.

    This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.

  3. Investigation of wellbore microannulus permeability under stress via experimental wellbore mock-up and finite element modeling

    DOE PAGES

    Gomez, Steven P.; Sobolik, Steve R.; Matteo, Edward N.; ...

    2016-11-16

    This research aims to describe the microannulus region of the cement sheath-steel casing interface in terms of its compressibility and permeability. Here, a wellbore system mock-up was used for lab-scale testing, and was subjected to confining and casing pressures in a pressure vessel while measuring gas flow along the specimen’s axis. The flow was interpreted as the hydraulic aperture of the microannuli. Numerical joint models were used to calculate stress and displacement conditions of the microannulus region, where the mechanical stiffness and hydraulic aperture were altered in response to the imposed stress state and displacement across the joint interface.

  4. SWOT analysis to evaluate the programme of a joint online/onsite master's degree in environmental education through the students' perceptions.

    PubMed

    Romero-Gutierrez, Miguel; Jimenez-Liso, M Rut; Martinez-Chico, Maria

    2016-02-01

    This study shows the use of SWOT to analyse students' perceptions of an environmental education joint master's programme in order to determine if it runs as originally planned. The open answers given by students highlight the inter-university nature of the master's, the technological innovation used as major points, and the weaknesses in the management coordination or the duplicate contents as minor points. The external analysis is closely linked with the students' future jobs, their labour opportunities available to them after graduation. The innovative treatment of the data is exportable to the evaluation of programmes of other degrees because it allows the description linked to its characteristics and its design through the students' point of view. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Elution kinetics, antimicrobial activity, and mechanical properties of 11 different antibiotic loaded acrylic bone cement.

    PubMed

    Gálvez-López, Ruben; Peña-Monje, Alejandro; Antelo-Lorenzo, Ramón; Guardia-Olmedo, Juan; Moliz, Juan; Hernández-Quero, José; Parra-Ruiz, Jorge

    2014-01-01

    Antibiotic-loaded acrylic bone cements (ALABC) spacers are routinely used in the treatment of prosthetic joint infections. The objectives of our study were to evaluate different ALABC for elution kinetics, thermal stability, and mechanical properties. A 10 or 20% mixture (w/w) beads of medium viscosity bone cement (DePuy, Inc) and vancomycin (VAN), gentamycin (GM), daptomycin (DAP), moxifloxacin (MOX), rifampicin (RIF), cefotaxime (CTX), cefepime (FEP), amoxicillin clavulanate (AmC), ampicillin (AMP), meropenem (MER), and ertapenem (ERT) were formed and placed into wells filled with phosphate-buffered saline. Antibiotic concentrations were determined using high-performance liquid chromatography. Antimicrobial activity was tested against Micrococcus luteus ATCC 9341 or Escherichia coli ATCC 25922. AmC, AMP, and FEP concentration rapidly decreased after day 2, being almost undetectable at day 4. Sustained and high elution rates were observed with VAN, GM, MOX, and RIF for the 30-day duration of the experiment. DAP, MER, ERT, and CTX elution rates constantly decreased from day 4. All antibiotics tested retained antimicrobial activity proving thermal stability. Mechanical properties of ALABC were maintained except when RIF was used. © 2013.

  6. Development of Alkali Activated Geopolymer Masonry Blocks

    NASA Astrophysics Data System (ADS)

    Venugopal, K.; Radhakrishna; Sasalatti, Vinod

    2016-09-01

    Cement masonry units are not considered as sustainable since their production involves consumption of fuel, cement and natural resources and therefore it is essential to find alternatives. This paper reports on making of geopolymer solid & hollow blocks and masonry prisms using non conventional materials like fly ash, ground granulated blast furnace slag (GGBFS) and manufactured sand and curing at ambient temperature. They were tested for water absorption, initial rate of water absorption, dry density, dimensionality, compressive, flexural and bond-strength which were tested for bond strength with and without lateral confinement, modulus of elasticity, alternative drying & wetting and masonry efficiency. The properties of geopolymer blocks were found superior to traditional masonry blocks and the masonry efficiency was found to increase with decrease in thickness of cement mortar joints. There was marginal difference in strength between rendered and unrendered geopolymer masonry blocks. The percentage weight gain after 7 cycles was less than 6% and the percentage reduction in strength of geopolymer solid blocks and hollow blocks were 26% and 28% respectively. Since the properties of geopolymer blocks are comparatively better than the traditional masonry they can be strongly recommended for structural masonry.

  7. Hip Implant Modified To Increase Probability Of Retention

    NASA Technical Reports Server (NTRS)

    Canabal, Francisco, III

    1995-01-01

    Modification in design of hip implant proposed to increase likelihood of retention of implant in femur after hip-repair surgery. Decreases likelihood of patient distress and expense associated with repetition of surgery after failed implant procedure. Intended to provide more favorable flow of cement used to bind implant in proximal extreme end of femur, reducing structural flaws causing early failure of implant/femur joint.

  8. Nano clay-enhanced calcium phosphate cements and hydrogels for biomedical applications

    NASA Astrophysics Data System (ADS)

    Jammalamadaka, Udayabhanu

    Biomaterials are used as templates for drug delivery, scaffolds in tissue engineering, grafts in surgeries, and support for tissue regeneration. Novel biomaterial composites are needed to meet multifaceted requirements of compatibility, ease of fabrication and controlled drug delivery. Currently used biomaterials in orthopedics surgeries suffer limitations in toxicity and preventing infections. Polymethyl methacrylate (PMMA) used as bone cement suffers from limitations of thermal necrosis and monomer toxicity calls for development of better cementing biomaterials. A biodegradable/bioresorbable cement with good mechanical properties is needed to address this short coming. Metal implants used in fixing fractures or total joint replacement needs improvements in preventing biofilm formation and better tissue integration. This research addressed the above mentioned research gaps by formulating novel biomaterial composites. Calcium phosphate cements are the alternative bone cements that are bioresorbable and promote tissue integration. These cements lack sufficient mechanical strengths to be used in load bearing sites. The addition of nanoparticles is hypothesized to improve the mechanical properties without inducing toxicity to the tissue. This hypothesis was tested by evaluating compression and flexural strengths in addition to cytocompatibility tests. Results indicate that addition of nano-clay particles (halloysites nanotubes) improved the compressive strength and osteoinductive properties of calcium phosphate cements. To address the research need of preventing implant failure due to infection and aseptic loosening, novel coatings are needed. Hydrogels are well establish for their ability to mimic in vivo environment, promote cell viability and as drug delivery vehicles. Use of composites of hydrogels and drug-loaded nanoparticles to prevent infection was evaluated. Cytocompatibility results indicate good cell viability. Antibacterial results show sustained release of antibiotics from composite hydrogels and good zones of inhibition on agar plates inoculated with bacterial cultures. Fabricating a complex three-dimensional (3D) scaffold for tissue engineering was a huge challenge. With advancements in additive manufacturing, this research gap was addressed. Methods are needed to fabricate patient specific grafts made from biocompatible biomaterials. In this research, 3D printing was used as a platform to explore new biomaterials as grafts or scaffolds for tissue engineering. Computerized tomography scans were used to fabricate patient-specific grafts. The use of calcium cements to fabricate three-dimensionally complex scaffold or grafts reported in this research holds potential in personalized medicine.

  9. Human ossicular-joint flexibility transforms the peak amplitude and width of impulsive acoustic stimulia)

    PubMed Central

    Gottlieb, Peter K.; Vaisbuch, Yona

    2018-01-01

    The role of the ossicular joints in the mammalian middle ear is still debated. This work tests the hypothesis that the two synovial joints filter potentially damaging impulsive stimuli by transforming both the peak amplitude and width of these impulses before they reach the cochlea. The three-dimensional (3D) velocity along the ossicular chain in unaltered cadaveric human temporal bones (N = 9), stimulated with acoustic impulses, is measured in the time domain using a Polytec (Waldbronn, Germany) CLV-3D laser Doppler vibrometer. The measurements are repeated after fusing one or both of the ossicular joints with dental cement. Sound transmission is characterized by measuring the amplitude, width, and delay of the impulsive velocity profile as it travels from the eardrum to the cochlea. On average, fusing both ossicular joints causes the stapes velocity amplitude and width to change by a factor of 1.77 (p = 0.0057) and 0.78 (p = 0.011), respectively. Fusing just the incudomalleolar joint has a larger effect on amplitude (a factor of 2.37), while fusing just the incudostapedial joint decreases the stapes velocity on average. The 3D motion of the ossicles is altered by fusing the joints. Finally, the ability of current computational models to predict this behavior is also evaluated.

  10. Diagnosis of Persistent Infection in Prosthetic Two-Stage Exchange: Evaluation of the Effect of Sonication on Antibiotic Release from Bone Cement Spacers.

    PubMed

    Mariaux, Sandrine; Furustrand Tafin, Ulrika; Borens, Olivier

    2018-01-01

    Introduction : When treating periprosthetic joint infection with a two-stage procedure, antibiotic-impregnated spacers can be used in the interval between prosthetic removal and reimplantation. In our experience, cultures of sonicated spacers are most often negative. The objective of the study was to assess whether that sonication causes an elution of antibiotics, leading to elevated antibiotic concentrations in the sonication fluid inhibiting bacterial growth and thus causing false-negative cultures. Methods : A prospective monocentric study was performed from September 2014 to March 2016. Inclusion criteria were a two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Spacers were made of gentamicin-containing cement to which tobramycin and vancomycin were added. Antibiotic concentrations in the sonication fluid were determined by mass-spectometry (LC-MS). Results : 30 patients were identified (15 hip and 14 knee and 1 ankle arthroplasties). No cases of culture positive sonicated spacer fluid were observed in our serie. In the sonication fluid median concentrations of 13.2µg/ml, 392 µg/ml and 16.6 µg/ml were detected for vancomycin, tobramycin and gentamicin, respectively. According to the European Committee on antimicrobial susceptibility testing (EUCAST), these concentrations released from cement spacer during sonication are higher than the minimal inhibitory concentrations (MICs) for most bacteria relevant in prosthetic joint infections. Conclusion: Spacer sonication cultures remained sterile in all of our cases. Elevated concentrations of antibiotics released during sonication could explain partly negative-cultured sonicated spacers. Indeed, the absence of antibiotic free interval during the two-stages can also contribute to false-negative spacers sonicated cultures.

  11. Evaluation of Different Experience Levels of Orthopaedic Residents Effect on Polymethylmethacrylate (PMMA) Bone Cement Mechanical Properties.

    PubMed

    Struemph, Jonathon M; Chong, Alexander C M; Wooley, Paul H

    2015-01-01

    PMMA bone cement is a brittle material and the creation of defects that increase porosity during mixing or injecting is a significant factor in reducing its mechanical properties. The goal during residency training is to learn how to avoid creating increased porosity during mixing and injecting the material. The aim of this study was to evaluate and compare tensile and compression strength for PMMA cement mixed by intern orthopaedic residents (PGY-1) and senior orthopaedic residents (PGY-5). The hypothesis was that the mechanical properties of PMMA cement mixed by PGY-5 would be significantly better than PMMA cement mixed by PGY-1 residents. Four PGY-1 and four PGY-5 orthopaedic residents each prepared eight tensile specimens. The bone cement used was Simplex™ P bone cement (Stryker Howmedica Osteonics, Mahwah, NJ) under vacuum mixing in a cement-delivery system. Tensile testing of the specimens was performed in an MTS Bionix servohydraulic materials testing system with loading rate of 2.54 mm/min at room temperature. The mean and standard deviation of the ultimate tensile strength (UTS) for each orthopaedic resident group was calculated. The compression specimens were cylinders formed with a central core to mimic a prosthetic implant. Ten samples from each orthopaedic resident were tested using the same MTS system under identical conditions at room temperature. The specimens were loaded from -50 N to complete structural failure at the rate of 20 mm/min. The ultimate compressive strength (UCS) was then determined and the mean and standard deviation calculated for each group. The average UTS of the bone cement for the PGY-1 and PGY-5 residents was 37.5 ± 4.5 MPa and 39.2 ± 5.0 MPa, respectively, and there was no statistically significant difference between the two groups. For the tensile elastic modulus of the bone cement, the results for the PGY-1 and PGY-5 residents were 2.40 ± 0.09 GPa and 2.44 ± 0.08 GPa, respectively, and again there was no statistically significant difference. For the compression elastic modulus of the bone cement, the results for the PGY-1 and PGY-5 residents were 1.19 ± 0.13 GPa and 1.21 ± 0.18 GPa, respectively, with no statistically significant difference. However, the UCS of the bone cement for the PGY-1 and PGY-5 residents was 87.4 ± 5.8 MPa and 91.1 ± 4.5 MPa, respectively, and there was a statistically significant difference between the groups. The PMMA specimens prepared by both the PGY-1 and PGY-5 resident groups had similar characteristics during tensile and compression testing, and were similar to known standards. Although mixing and applying bone cement is an important skill for joint replacement surgery, our results indicate that no special training appears to be necessary for orthopaedic residents. Rather, a basic training video demonstrating manufacturer standard procedure is all that is necessary. The results of this study indicate the importance of experience in bone cement mixing and injecting on cement mechanical properties, but indicate that no special training appears to be necessary for orthopaedic residents.

  12. Evaluation of the long-term efficacy of K-Othrine® PolyZone on three surfaces against laboratory reared Anopheles gambiae in semi-field conditions.

    PubMed

    Dunford, James C; Estep, Alden S; Waits, Christy M; Richardson, Alec G; Hoel, David F; Horn, Karin; Walker, Todd W; Blersch, Jessika S; Kerce, Jerry D; Wirtz, Robert A

    2018-02-23

    In this semi-field study, a new polymer-enhanced deltamethrin formulation, K-Othrine ® PolyZone, was compared to a standard deltamethrin product for residual activity against a susceptible strain of laboratory-reared Anopheles gambiae using standard WHO cone bioassays. Residual insecticide efficacy was recorded after exposure to metal, cement and wood panels maintained in experimental huts in sub-tropical environmental conditions in north central Florida, USA, and panels stored in a climate controlled chamber located at the Centers for Disease Control and Prevention, Georgia, USA. K-Othrine ® PolyZone demonstrated 100% control on metal and cement panels 1 year post application and > 80% control on wood panels up to 6 mo. The new formulation should be considered for use in indoor residual spray programmes requiring long-term control of malaria vectors.

  13. Progress and Achievements at the Mid Term Stage of the Dragon 3 Programme

    NASA Astrophysics Data System (ADS)

    Desnos, Yves-Louis; Li, Zengyuan; Zmuda, Andy; Gao, Zhihai

    2014-11-01

    The Dragon Programme is a joint undertaking between ESA and the Ministry of Science and Technology (MOST) of China and the National Remote Sensing Center of China (NRSCC). Its purpose is to encourage increased exploitation of ESA and Chinese space resources within China as well as stimulate increased scientific cooperation in the field of Earth Observation (EO) science and applications between China and Europe. Since 2004, this pioneering programme has become a model for scientific and technological cooperation between China and Europe. By successfully encouraging joint research using ESA, Third Party Missions and Chinese EO data across a range of thematic areas, Dragon continues to deliver outstanding scientific results. The programme has successfully completed two phases, Dragon 1 from 2004 to 2008, Dragon 2 from 2008 to 2012. The third phase of Dragon was started in 2012 and will be completed in 2016. The Dragon 3 project teams are led by leading EO scientists and young scientists are also engaged on the projects. Advanced training in land, ocean and atmospheric applications is a feature of the programme and a course on land and one course on ocean applications have been successfully held in 2012 and 2013 in China. Here-in provided is an overview of the results, reporting and training activities at the mid-term stage of the programme.

  14. Fatigue Rated Fastener Systems

    DTIC Science & Technology

    1985-11-01

    programme part also .how. that the »tatement "the higher th«. load traust.,, the shorter the tallgu. lite could not b. confirmed for all Joints. It might...realistic fatigue loading: the lite improvement mechanisms are more marked in these Joints than in .-.-* luad transfer/low secondary bending Joints...7050-T76 PRIMER REAM HI-LOK TEST SERIES NOT CLEARANCE 10-30 34432 11832 GH3 JRFS-A") COLD WORK VRFS -B) INTERFERENCE 15-35 >16773 >16044

  15. Perioperative Care of a Patient with Refractory Idiopathic Thrombocytopenic Purpura Undergoing Total Knee Arthroplasty

    PubMed Central

    Gudimetla, Veera; Stewart, Andrew; Luscombe, Karen L; Charalambous, Charalambos P

    2012-01-01

    Idiopathic thrombocytopenic purpura (ITP) is an autoimmune disorder leading to low platelet count and an increased risk of bleeding. Major joint replacement surgery in a patient with ITP can be associated with severe postoperative bleeding. We present our experience of perioperative management in a patient with severe refractory chronic idiopathic thrombocytopenic purpura who successfully underwent a cemented total knee replacement. PMID:23269964

  16. Failed Reverse Total Shoulder Arthroplasty Caused by Recurrent Candida glabrata Infection with Prior Serratia marcescens Coinfection

    PubMed Central

    Skedros, John G.; Keenan, Kendra E.; Updike, Wanda S.; Oliver, Marquam R.

    2014-01-01

    This report describes a 58-year-old insulin-dependent diabetic male patient who initially sustained a proximal humerus fracture from a fall. The fracture fixation failed and then was converted to a humeral hemiarthroplasty, which became infected with Candida glabrata and Serratia marcescens. After these infections were believed to be cured with antibacterial and antifungal treatments and two-stage irrigation and debridement, he underwent conversion to a reverse total shoulder arthroplasty. Unfortunately, the C. glabrata infection recurred and, nearly 1.5 years after implantation of the reverse total shoulder, he had a resection arthroplasty (removal of all implants and cement). His surgical and pharmacologic treatment concluded with (1) placement of a tobramycin-impregnated cement spacer also loaded with amphotericin B, with no plan for revision arthroplasty (i.e., the spacer was chronically retained), and (2) chronic use of daily oral fluconazole. We located only three reported cases of Candida species causing infection in shoulder arthroplasties (two C. albicans, one C. parapsilosis). To our knowledge, a total shoulder arthroplasty infected with C. glabrata has not been reported, nor has a case of a C. glabrata and S. marcescens periprosthetic coinfection in any joint. In addition, it is well known that S. marcescens infections are uncommon in periprosthetic joint infections. PMID:25431708

  17. Perioperative mortality after hemiarthroplasty related to fixation method.

    PubMed

    Costain, Darren J; Whitehouse, Sarah L; Pratt, Nicole L; Graves, Stephen E; Ryan, Philip; Crawford, Ross W

    2011-06-01

    The appropriate fixation method for hemiarthroplasty of the hip as it relates to implant survivorship and patient mortality is a matter of ongoing debate. We examined the influence of fixation method on revision rate and mortality. We analyzed approximately 25,000 hemiarthroplasty cases from the AOA National Joint Replacement Registry. Deaths at 1 day, 1 week, 1 month, and 1 year were compared for all patients and among subgroups based on implant type. Patients treated with cemented monoblock hemiarthroplasty had a 1.7-times higher day-1 mortality compared to uncemented monoblock components (p < 0.001). This finding was reversed by 1 week, 1 month, and 1 year after surgery (p < 0.001). Modular hemiarthroplasties did not reveal a difference in mortality between fixation methods at any time point. This study shows lower (or similar) overall mortality with cemented hemiarthroplasty of the hip.

  18. Influence of training on the biokinematics in trotting Andalusian horses.

    PubMed

    Cano, M R; Miró, F; Diz, A M; Agüera, E; Galisteo, A M

    2000-11-01

    The aim of this study was to determine the influence of a 10-month training programme on the linear, temporal and angular characteristics of the fore and hind limbs at the trot in the Andalusian horse, using standard computer-aided videography. Sixteen male Andalusian horses were observed before and after training. Six strides were randomly selected for analysis in each horse and linear, temporal and angular parameters were calculated for fore and hind limbs. The training programme used here produced significant changes in kinematic parameters, such as shortening of stride length, and increase in swing duration and a decrease in hind limb stance percentage. No significant differences were recorded in the angular values for the forelimb joints. In trained horses, the more proximal joints of the hind limb, especially the hip and stifle, had a greater flexion while the fetlock showed a smaller extension angle. At the beginning of the swing phase, hip and stifle joints presented angles that were significantly more flexed. When the hind limbs came into contact with the ground, all the joints presented greater flexion after training.

  19. Effectiveness of telerehabilitation programme following surgery in shoulder impingement syndrome (SIS): study protocol for a randomized controlled non-inferiority trial.

    PubMed

    Pastora-Bernal, Jose-Manuel; Martín-Valero, Rocío; Barón-López, Francisco Javier; García-Gómez, Oscar

    2017-02-23

    Shoulder pain is common in society, with high prevalence in the general population. Shoulder impingement syndrome (SIS) is the most frequent cause. Patients suffer pain, muscle weakness and loss of movement in the affected joint. Initial treatment is predominantly conservative. The surgical option has high success rates and is often used when conservative strategy fails. Traditional physiotherapy and post-operative exercises are needed for the recovery of joint range, muscle strength, stability and functionality. Telerehabilitation programmes have shown positive results in some orthopaedic conditions after surgery. Customized telerehabilitation intervention programmes should be developed to recover shoulder function after SIS surgery. The objective of this study is to evaluate the feasibility and effectiveness of a telerehabilitation intervention compared with usual care in patients after subacromial decompression surgery. We will compare an intervention group receiving videoconferences and a telerehabilitation programme to a control group receiving traditional physiotherapy intervention in a single-blind, randomized controlled non-inferiority trial study design. Through this study, we will further develop our preliminary data set and practical experience with the telerehabilitation programmes to evaluate their effectiveness and compare this with traditional intervention. We will also explore patient satisfaction and cost-effectiveness. Patient enrolment is ongoing. ClinicalTrials.gov, NCT02909920 . 14 September 2016.

  20. Science Teachers Accelerated Programme Model: A Joint Partnership in the Pacific Region

    ERIC Educational Resources Information Center

    Sharma, Bibhya; Lauano, Faatamali'i Jenny; Narayan, Swasti; Anzeg, Afshana; Kumar, Bijeta; Raj, Jai

    2018-01-01

    The paper heralds a new pedagogical model known as the Science Teachers Accelerated Programme as a platform to upgrade the qualifications of secondary school science teachers throughout the Pacific region. Based on a tripartite partnership between a higher education provider, a regional government and a cohort of science teachers, the model offers…

  1. Experiential Learning in Education for Sustainable Development: Experiences from a Czech-Kazakh Social Learning Programme

    ERIC Educational Resources Information Center

    Cincera, Jan

    2013-01-01

    The article presents experience from a joint Czech-Kazakh project based on experiential education. The goal of the project was to develop trust and cooperation between various stakeholders to promote effective public participation in local sustainable development issues in Kazakhstan. The article describes the methodology of the programme and its…

  2. Studying Computer Science in a Multidisciplinary Degree Programme: Freshman Students' Orientation, Knowledge, and Background

    ERIC Educational Resources Information Center

    Kautz, Karlheinz; Kofoed, Uffe

    2004-01-01

    Teachers at universities are facing an increasing disparity in students' prior IT knowledge and, at the same time, experience a growing disengagement of the students with regard to involvement in study activities. As computer science teachers in a joint programme in computer science and business administration, we made a number of similar…

  3. Wellbore Seal Repair Using Nanocomposite Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stormont, John

    2016-08-31

    Nanocomposite wellbore repair materials have been developed, tested, and modeled through an integrated program of laboratory testing and numerical modeling. Numerous polymer-cement nanocomposites were synthesized as candidate wellbore repair materials using various combinations of base polymers and nanoparticles. Based on tests of bond strength to steel and cement, ductility, stability, flowability, and penetrability in opening of 50 microns and less, we identified Novolac epoxy reinforced with multi-walled carbon nanotubes and/or alumina nanoparticles to be a superior wellbore seal material compared to conventional microfine cements. A system was developed for testing damaged and repaired wellbore specimens comprised of a cement sheathmore » cast on a steel casing. The system allows independent application of confining pressures and casing pressures while gas flow is measured through the specimens along the wellbore axis. Repair with the nanocomposite epoxy base material was successful in dramatically reducing the flow through flaws of various sizes and types, and restoring the specimen comparable to an intact condition. In contrast, repair of damaged specimens with microfine cement was less effective, and the repair degraded with application of stress. Post-test observations confirm the complete penetration and sealing of flaws using the nanocomposite epoxy base material. A number of modeling efforts have supported the material development and testing efforts. We have modeled the steel-repair material interface behavior in detail during slant shear tests, which we used to characterize bond strength of candidate repair materials. A numerical model of the laboratory testing of damaged wellbore specimens was developed. This investigation found that microannulus permeability can satisfactorily be described by a joint model. Finally, a wellbore model has been developed that can be used to evaluate the response of the wellbore system (casing, cement, and microannulus), including the use of either cement or a nanocomposite in the microannulus to represent a repaired system. This wellbore model was successfully coupled with a field-scale model of CO 2 injection, to enable predictions of stress and strains in the wellbore subjected to subsurface changes (i.e. domal uplift) associated with fluid injection.« less

  4. Shear Behaviour and Acoustic Emission Characteristics of Bolted Rock Joints with Different Roughnesses

    NASA Astrophysics Data System (ADS)

    Wang, Gang; Zhang, Yongzheng; Jiang, Yujing; Liu, Peixun; Guo, Yanshuang; Liu, Jiankang; Ma, Ming; Wang, Ke; Wang, Shugang

    2018-06-01

    To study shear failure, acoustic emission counts and characteristics of bolted jointed rock-like specimens are evaluated under compressive shear loading. Model joint surfaces with different roughnesses are made of rock-like material (i.e. cement). The jointed rock masses are anchored with bolts with different elongation rates. The characteristics of the shear mechanical properties, the failure mechanism, and the acoustic emission parameters of the anchored joints are studied under different surface roughnesses and anchorage conditions. The shear strength and residual strength increase with the roughness of the anchored joint surface. With an increase in bolt elongation, the shear strength of the anchored joint surface gradually decreases. When the anchored structural plane is sheared, the ideal cumulative impact curve can be divided into four stages: initial emission, critical instability, cumulative energy, and failure. With an increase in the roughness of the anchored joint surface, the peak energy rate and the cumulative number of events will also increase during macro-scale shear failure. With an increase in the bolt elongation, the energy rate and the event number increase during the shearing process. Furthermore, the peak energy rate, peak number of events and cumulative energy will all increase with the bolt elongation. The results of this study can provide guidance for the use of the acoustic emission technique in monitoring and predicting the static shear failure of anchored rock masses.

  5. Integrated High-Speed Torque Control System for a Robotic Joint

    NASA Technical Reports Server (NTRS)

    Davis, Donald R. (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Valvo, Michael C. (Inventor); Askew, R. Scott (Inventor)

    2013-01-01

    A control system for achieving high-speed torque for a joint of a robot includes a printed circuit board assembly (PCBA) having a collocated joint processor and high-speed communication bus. The PCBA may also include a power inverter module (PIM) and local sensor conditioning electronics (SCE) for processing sensor data from one or more motor position sensors. Torque control of a motor of the joint is provided via the PCBA as a high-speed torque loop. Each joint processor may be embedded within or collocated with the robotic joint being controlled. Collocation of the joint processor, PIM, and high-speed bus may increase noise immunity of the control system, and the localized processing of sensor data from the joint motor at the joint level may minimize bus cabling to and from each control node. The joint processor may include a field programmable gate array (FPGA).

  6. A Crossover Trial Evaluating an Educational-Behavioral Joint Protection Programme for People with Rheumatoid Arthritis.

    ERIC Educational Resources Information Center

    Hammond, A.; Lincoln, N.; Sutcliffe, L.

    1999-01-01

    Joint protection, a self-management technique taught to people with rheumatoid arthritis, was used in a group education program. A crossover trial (N=35) was conducted. No significant changes in measures of pain, functional disability, grip strength, self-efficacy or helplessness occurred post-education, although this may have been due to the…

  7. Concrete and cement composites used for radioactive waste deposition.

    PubMed

    Koťátková, Jaroslava; Zatloukal, Jan; Reiterman, Pavel; Kolář, Karel

    2017-11-01

    This review article presents the current state-of-knowledge of the use of cementitious materials for radioactive waste disposal. An overview of radwaste management processes with respect to the classification of the waste type is given. The application of cementitious materials for waste disposal is divided into two main lines: i) as a matrix for direct immobilization of treated waste form; and ii) as an engineered barrier of secondary protection in the form of concrete or grout. In the first part the immobilization mechanisms of the waste by cement hydration products is briefly described and an up-to date knowledge about the performance of different cementitious materials is given, including both traditional cements and alternative binder systems. The advantages, disadvantages as well as gaps in the base of information in relation to individual materials are stated. The following part of the article is aimed at description of multi-barrier systems for intermediate level waste repositories. It provides examples of proposed concepts by countries with advanced waste management programmes. In the paper summary, the good knowledge of the material durability due to its vast experience from civil engineering is highlighted however with the urge for specific approach during design and construction of a repository in terms of stringent safety requirements. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Reciprocal Learning by Experienced Teachers and Their Educators on a Master's Degree Programme in the Netherlands

    ERIC Educational Resources Information Center

    van Swet, Jacqueline; Ponte, Petra

    2007-01-01

    This article reports findings from a case study into reciprocal learning in tutor groups in a research-based master's programme, run jointly by Roehampton University, London, UK and Fontys OSO, The Netherlands. The research was designed to investigate to what extent, and how, forms of reciprocal learning arose in tutor groups for experienced…

  9. Effect of shape on bone cement polymerization time in knee joint replacement surgery

    PubMed Central

    Yoon, Jung-Ro; Ko, Young-Rok; Shin, Young-Soo

    2018-01-01

    Abstract Background: Although many factors are known to influence the polymerization time of bone cement, it remains unclear which bone cement shape predicts the precise polymerization time. The purpose of this study was to investigate whether different cement shapes influenced polymerization time and to identify the relationship between cement shape and ambient operating theater temperature, relative humidity, and equilibration time. Methods: Samples were gathered prospectively from 237 patients undergoing primary total knee arthroplasty. The cement components were made into 2 different shapes: lump and pan. The time at which no macroscopic indentation of both cement models was possible was recorded as the polymerization time. Results: There was no significant difference between hand mixing (lump shape: 789.3 ± 128.4 seconds, P = .591; pan shape: 899.3 ± 152.2 seconds, P = .584) and vacuum mixing (lump shape: 780.2 ± 131.1 seconds, P = .591; pan shape: 909.9 ± 143.3 seconds, P = .584) in terms of polymerization time. Conversely, the polymerization time was significantly shorter for Antibiotic Simplex (lump shape: 757.4 ± 114.9 seconds, P = .001; pan shape: 879.5 ± 125.0 seconds, P < .001) when compared with Palacos R+G (lump shape: 829.0 ± 139.3 seconds, P = .001; pan shape: 942.9 ± 172.0 seconds, P < .001). Polymerization time was also significantly longer (P < .001) for the pan shape model (904 ± 148.0 seconds) when compared with the lump shape model (785.2 ± 129.4 seconds). In addition, the polymerization time decreased with increasing temperature (lump shape: R2 = 0.334, P < .001; pan shape: R2 = 0.375, P < .001), humidity (lump shape: R2 = 0.091, P < .001; pan shape: R2 = 0.106, P < .001), and equilibration time (lump shape: R2 = 0.073, P < .001; pan shape: R2 = 0.044, P < .001). Conclusions: The polymerization time was equally affected by temperature, relative humidity, and equilibration time regardless of bone cement shape. Furthermore, the pan shape model better reflected the cement polymerization time between implant and bone compared with the lump shape model. The current findings suggest that, clinically, constant pressure with the knee in <45° of flexion needs to be applied until remaining pan shaped cement is completely polymerized. PMID:29703041

  10. Joint Peru/United States report on Peru/United States cooperative energy assessment. Volume 3. Annexes 2-7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-08-01

    This report presents the results of a brief study of industral, mining, and agricultural sector energy demands in Peru. The study establishes current energy demands and sectoral activities, and projects future energy needs through the year 2000. With respect to energy demands, the subsectors covered are: mining and non-ferrous metals, iron and steel, cement, oil refining, petrochemicals, fertilizers, and agriculture (major crops). Total energy demands for these subsectors are developed for 1976, 1985, and 2000, assuming full-capacity operation for the majority of the plants. Potential options developed for reducing energy use in these sectors are: increased coal use, improved energymore » efficiency in the manufacturing sector, use of agricultural wastes as fuel, possible displacement of oil by hydroelectricity, use of geothermal energy, increased use of water materials for the cement and construction industries, and possible promotion of cogeneration systems (electricity/steam). (MCW)« less

  11. [Primary Prevention of Mental Disorders in Children of Mentally Ill Parents. The Kanu Programme "Canoe--Moving Jointly Forward"].

    PubMed

    Linthorst, K; Bauer, U; Osipov, I; Pinheiro, P; Rehder, M

    2015-09-01

    Children of parents who suffer from mental health disorders are more likely to develop mental disorders than children of parents not suffering from mental disorders. For children at risk, preventive strategies are hardly available and, if available, rarely supported by a scientific evaluation. "Kanu - Gemeinsam weiterkommen (canoe - moving jointly forward)" is a preventive strategy that was developed within a research project focusing on primary prevention in children who live in families with parents affected by mental disorders. The intervention is characterised by a multi-modular concept and was tested in the adult psychiatric setting. Preliminary results indicate a preventive impact of the intervention programme. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Vancomycin-Loaded Polymethylmethacrylate Spacers Fail to Eradicate Periprosthetic Joint Infection in a Clinically Representative Mouse Model.

    PubMed

    Carli, Alberto V; Bhimani, Samrath; Yang, Xu; de Mesy Bentley, Karen L; Ross, F Patrick; Bostrom, Mathias P G

    2018-06-06

    Periprosthetic joint infection (PJI) remains a devastating complication following total joint arthroplasty. Current animal models of PJI do not effectively recreate the clinical condition and thus provide limited help in understanding why treatments fail. We developed a mouse model of the first-stage surgery of a 2-stage revision for PJI involving a 3-dimensionally printed Ti-6Al-4V implant and a mouse-sized cement spacer that elutes vancomycin. Vancomycin was mixed with polymethylmethacrylate (PMMA) cement and inserted into custom-made mouse-sized spacer molds. Twenty C57BL/6 mice received a proximal tibial implant and an intra-articular injection of 3 × 10 colony-forming units of Staphylococcus aureus Xen36. At 2 weeks, 9 mice underwent irrigation and debridement of the leg with revision of the implant to an articulating vancomycin-loaded PMMA spacer. Postoperatively, mice underwent radiography and serum inflammatory-marker measurements. Following euthanasia of the mice at 6 weeks, bone and soft tissues were homogenized to quantify bacteria within periprosthetic tissues. Implants and articulating spacers were either sonicated to quantify adherent bacteria or examined under scanning electron microscopy (SEM) to characterize the biofilm. Vancomycin-loaded PMMA spacers eluted vancomycin for ≤144 hours and retained antimicrobial activity. Control mice had elevated levels of inflammatory markers, radiographic evidence of septic loosening of the implant, and osseous destruction. Mice treated with a vancomycin-loaded PMMA spacer had significantly lower levels of inflammatory markers (p < 0.01), preserved tibial bone, and no intra-articular purulence. Retrieved vancomycin-loaded spacers exhibited significantly lower bacterial counts compared with implants (p < 0.001). However, bacterial counts in periprosthetic tissue did not significantly differ between the groups. SEM identified S. aureus encased within biofilm on control implants, while vancomycin-loaded spacers contained no bacteria. This animal model is a clinically representative model of PJI treatment. The results suggest that the antimicrobial effects of PMMA spacers are tightly confined to the articular space and must be utilized in conjunction with thorough tissue debridement and systemic antibiotics. These data provide what we believe to be the first insight into the effect of antibiotic-loaded cement spacers in a clinically relevant animal model and justify the adjunctive use of intravenous antibiotics when performing a 2-stage revision for PJI.

  13. Negative Pressure Wound Therapy Reduces the Effectiveness of Traditional Local Antibiotic Depot in a Large Complex Musculoskeletal Wound Animal Model

    DTIC Science & Technology

    2012-09-01

    in particular, local antibiotic delivery via polymethylmethacrylate (PMMA) bone cement and negative pressure wound therapy (NPWT). In cases with gross...release of gentamicin from polymethylmethacrylate beads. An experimental and pharmacoki- netic study. J Bone Joint Surg Br. 1978;60-B:270 275. 7...diffusion from antibiotic-impregnated polymethylmethacrylate beads. Clin Orthop Relat Res. 1992;278:244 252. Stinner et al J Orthop Trauma Volume

  14. FAO UN-REDD- INPE Joint Programme on Forest Monitoring Systems based on RS and GIS techniques

    NASA Astrophysics Data System (ADS)

    Jonckheere, I. G.; FAO UN-REDD MRV Team

    2010-12-01

    Capacity Development and Training for National Forest Monitoring Systems for Reducing Emissions from Deforestation and Forest Degradation in Developing Countries (REDD+) REDD+, which stands for ’Reducing Emissions from Deforestation and Forest Degradation in Developing Countries’ - is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. The UN-REDD Programme, a collaborative partnership between FAO, UNDP and UNEP launched in September 2008, supports countries to develop capacity to REDD+ and to implement a future REDD+ mechanism in a post-2012 climate regime. The programme works at both the national and global scale, through support mechanisms for country-driven REDD strategies and international consensus-building on REDD+ processes. The UN-REDD Programme gathers technical teams from around the world to develop common approaches, analyses and guidelines on issues such as measurement, reporting and verification (MRV) of carbon emissions and flows, remote sensing, and greenhouse gas inventories. Within the partnership, FAO supports countries on technical issues related to forestry and the development of cost effective and credible MRV processes for emission reductions. While at the international level, it fosters improved guidance on MRV approaches, including consensus on principles and guidelines for MRV and training programmes. It provides guidance on how best to design and implement REDD+, to ensure that forests continue to provide multiple benefits for livelihoods and biodiversity to societies while storing carbon at the same time. Other areas of work include national forest assessments and monitoring of in-country policy and institutional change. FAO and INPE (Brazilian Space Agency) have joint forces through a MoU signed last year in Copenhagen. A major joint programme has been agreed upon to set up national forest satellite monitoring systems in the developing countries and to train them in order to get them ready for REDD+. The outcomes about the role of satellite remote sensing technologies as a tool for monitoring, assessment, reporting and verification of carbon credits and co-benefits under the REDD+ mechanism are here presented.

  15. A Joint Vision for Secondary and Higher Education for All in Europe: The Road towards Realising Sustainable Development Goal 4 in Europe

    ERIC Educational Resources Information Center

    European Students' Union, 2016

    2016-01-01

    The present joint action programme is proposed by the Organising Bureau of European School Student Unions (OBESSU), the European Students' Union (ESU), and Education International (EI) to their members and partners, in order to advance the 2030 Agenda for Sustainable Development and its 17 related goals, which the United Nations adopted in…

  16. Mating of a PROSTALAC spacer with an intramedullary nail for reconstruction of an infected interprosthetic femoral shaft fracture: a case report.

    PubMed

    Kamath, Atul F; Austin, Daniel; Lee, Gwo-Chin

    2012-08-01

    Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer mated with an intramedullary nail. The acetabulum was then exposed and the necrotic cartilage was removed and curetted. The acetabulum was reamed to accept a PROSTALAC acetabular shell. The shell was cemented into the acetabulum with antibiotic cement. The custom-made spacer was then inserted distally first into the tibia. The distal end of the intramedullary nail was interlocked with a bicortical bolt to minimise nail rotation. Antibiotic-impregnated cement was moulded around the nail and spacer. The proximal end of the spacer was then reduced into the acetabular socket, and the joint was irrigated and the wound closed. A customised abduction brace was fitted, and partial weight bearing was allowed. Sufficient leg length, soft-tissue tension, and range of hip motion were restored, and a total femur and constrained liner was re-implanted 4 months later. Mating of an intramedullary nail with a PROSTALAC spacer is a viable reconstructive option.

  17. Primary cement spacers: a cost-effective, durable limb salvage option for knee tumors.

    PubMed

    Puri, Ajay; Gulia, Ashish; Pruthi, Manish; Koushik, S

    2012-08-01

    Of a total of 818 limb sparing resections in the lower limb requiring reconstruction between December 2002 and April 2010 at our centre, primary cement spacers were used in 15 cases. In three cases they were used as joint sparing intercalary reconstructions and in 12 cases knee arthrodesis was done. Implants used to provide stability to the construct included stacked intramedullary Kuntscher nails in four, an interlocking nail in one, plates in two and a combination of nail with plate in eight. Mean length of bone resected was 18 cm. Mean follow-up was 26 months (10-87 months). There were no local recurrences and none of the spacers needed revision for mechanical failure. The Musculoskeletal Tumor Society score for patients ranged from 20 to 29 with a mean of 24 (80%). Patients with intercalary resection had better functional scores than those with arthrodesis. The construct was successfully revised to a vascularised fibula arthrodesis or prosthesis with good eventual function in three cases. Cement spacers are a suitable cost-effective, durable reconstruction modality in selected patients with good functional outcomes. They are an option to amputation in patients with financial constraints and those that present with large volume or infected fungating tumors. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Control technology assessment of hazardous-waste-disposal operations in chemicals manufacturing: in-depth survey report of San Juan Cement Company, Dorado, Puerto Rico, November 1981

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crandall, M.S.

    1982-07-01

    A visit was made to the San Juan Cement Company, Dorado, Puerto Rico to evaluate control methods for a storage and delivery system for hazardous wastes used in a demonstration project as a supplemental fuel for cofiring a cement kiln. Analysis of the material during the visit revealed the presence of methylene chloride, carbon-tetrachloride, chloroform, acetone, hexane, ethanol, and ethyl acetate. Steel storage tanks were placed on an impermeable concrete slab surrounded by a sealed retaining wall. Steel piping with all welded joints carried the waste fuels from storage tanks to the kiln, where fuels were injected through a speciallymore » fabricated burner. Vapor emissions were suppressed by venting the displaced vapor through a recycle line. Exhaust gases from the kiln passed through a bag house type dust collector, and were vented to the atmosphere through a single stack. Half-mask air-purifying respirators were used when in the hazardous-waste storage/delivery area. Neoprene gloves were used when performing tasks with potential skin contact. Hard hats, safety glasses, and safety boots were all worn. The author concludes that the control methods used seemed effective in suppressing vapor emissions.« less

  19. Drug elution from high-dose antibiotic-loaded acrylic cement: a comparative, in vitro study.

    PubMed

    Gasparini, Giorgio; De Gori, Marco; Calonego, Giovanni; Della Bora, Tommaso; Caroleo, Benedetto; Galasso, Olimpio

    2014-11-01

    High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing peri-prosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians toward alternative antimicrobial formulations loaded into acrylic bone cement. The aim of this in vitro study was to determine the elution kinetics of 14 different high-dose ALACs. All ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing over time, and elution curves strictly adhered to a nonlinear regression analysis formula. Among aminoglycosides, commonly seen as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, a class of antibiotics that should be considered to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution than teicoplanin. Clindamycin, which can be associated with aminoglycosides to prepare ALACs and represents a useful option against the most common pathogens responsible for PJIs, showed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multidrug-resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics not routinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent a useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study. Copyright 2014, SLACK Incorporated.

  20. A pre-operative group rehabilitation programme provided limited benefit for people with severe hip and knee osteoarthritis.

    PubMed

    Wallis, Jason A; Webster, Kate E; Levinger, Pazit; Fong, Cynthia; Taylor, Nicholas F

    2014-01-01

    To determine if a pre-operative group rehabilitation programme can improve arthritis self-efficacy for people with severe hip and knee osteoarthritis. Single group, repeated measures design: 4-week baseline phase followed by a 6-week intervention phase of water exercise, and education with self-management strategies. The primary outcome was arthritis self-efficacy. The secondary outcomes were measures of pain (WOMAC), activity limitation (WOMAC), activity performance (30 s chair stand test, 10 m walk test) and health-related quality of life (EuroQol). Twenty participants (10 knee osteoarthritis and 10 hip osteoarthritis) with a mean age of 71 years (SD 7) attended 92% (SD 10%) of the scheduled sessions. All measures demonstrated baseline stability between two time points for measurements at week 1 and measurements at week 4. After the 6-week intervention programme there were no significant improvements for arthritis self-efficacy. There was a 12% increase for fast walking speed (mean increase of 0.14 m/s, 95% CI 0.07, 0.22). There were no significant improvements for other secondary outcomes. A pre-operative water-based exercise and educational programme did not improve arthritis self-efficacy, self-reported pain and activity limitation, and health-related quality of life for people with hip and knee osteoarthritis who were candidates for joint replacement. While there was a significant increase in one measure of activity performance (walking speed), these findings suggest the current programme may be of little value. Implications for Rehabilitation This pre-operative group rehabilitation programme for people with severe hip and knee osteoarthritis did not change arthritis self-efficacy, pain, activity limitation and health-related quality of life. This programme may have little value in preparing people for joint replacement surgery. The optimal pre-operative programme requires further design and investigation.

  1. [S3 Guideline. Part 3: Non-Traumatic Avascular Necrosis in Adults - Surgical Treatment of Atraumatic Avascular Femoral Head Necrosis in Adults].

    PubMed

    Maus, U; Roth, A; Tingart, M; Rader, C; Jäger, M; Nöth, U; Reppenhagen, S; Heiss, C; Beckmann, J

    2015-10-01

    The present article describes the guidelines for the surgical treatment of atraumatic avascular necrosis (aFKN). These include joint preserving and joint replacement procedures. As part of the targeted literature, 43 publications were included and evaluated to assess the surgical treatment. According to the GRADE and SIGN criteria level of evidence (LoE), grade of recommendation (EC) and expert consensus (EK) were listed for each statement and question. The analysed studies have shown that up to ARCO stage III, joint-preserving surgery can be performed. A particular joint-preserving surgery currently cannot be recommended as preferred method. The selection of the method depends on the extent of necrosis. Core decompression performed in stage ARCO I (reversible early stage) or stage ARCO II (irreversible early stage) with medial or central necrosis with an area of less than 30 % of the femoral head shows better results than conservative therapy. In ARCO stage III with infraction of the femoral head, the core decompression can be used for a short-term pain relief. For ARCO stage IIIC or stage IV core decompression should not be performed. In these cases, the indication for implantation of a total hip replacement should be checked. Additional therapeutic procedures (e.g., osteotomies) and innovative treatment options (advanced core decompression, autologous bone marrow, bone grafting, etc.) can be discussed in the individual case. In elective hip replacement complications and revision rates have been clearly declining for decades. In the case of an underlying aFKN, however, previous joint-preserving surgery (osteotomies and grafts in particular) can complicate the implantation of a THA significantly. However, the implant life seems to be dependent on the aetiology. Higher revision rates for avascular necrosis are particularly expected in sickle cell disease, Gaucher disease, or kidney transplantation patients. Furthermore, the relatively young age of the patient with avascular necrosis should be seen as the main risk factor for higher revision rate. The results after resurfacing (today with known restricted indications) and cemented as well as cementless THA in aFKN are comparable for the appropriate indication to those in coxarthrosis or other diagnoses. Regardless of the underlying disease endoprosthetic treatment in aFKN leads to good results. Both cemented and cementless fixation techniques can be recommended. Georg Thieme Verlag KG Stuttgart · New York.

  2. Structural and diagenetic evolution of deformation bands in contractional and extensional tectonic regimes

    NASA Astrophysics Data System (ADS)

    Eichhubl, P.; O'Brien, C. M.; Elliott, S. J.

    2016-12-01

    Mechanisms of brittle deformation of sediments and sedimentary rock change with burial because of increasing confining stress, change in pore fluid chemical and temperature conditions, and diagenetic state. In the field, these changes are observed in a transition from early non-cataclastic to later cataclastic deformation bands and to joint-based structures. Jurassic eolian sandstones in the San Rafael monocline and adjacent San Rafael Desert region, Utah, allow comparison of deformation band structures and their diagenetic attributes in contractional and extensional tectonic settings in close proximity. In the Entrada and Navajo Sandstones, we observe up to six generations of deformation bands, with earliest non-cataclastic bands having diffuse boundaries to host rock, and short and irregular traces. Later bands are cataclastic, more sharply defined, with long and straight traces. Cataclastic bands in the San Rafael monocline are interpreted to form as reverse faults during progressive rotation of the steeply dipping fold limb, resulting in an array of bands of varying dip. Bands in the San Rafael Desert form as normal faults with a narrower dip range. Although structural characteristics of bands differ in extensional and contractional tectonic regimes, cataclastic bands in either regime have comparable amount of porosity loss and quartz cementation indicating that tectonic regime does not influence band diagenesis. Abundance of quartz cement in bands, determined by point counting of SEM images, increases from earlier to later generations of bands and, within a single generation, with increasing slip along the band, reaching up to 24% of band volume. This trend is attributed to an increase in cataclasis with increasing host rock cementation and confining stress during burial, and, within the same generation, with increasing slip. Porosity loss by cementation tends to dominate over porosity loss by mechanical compaction. These findings demonstrate that quartz cementation and thus band permeability are primarily controlled by the degree of cataclasis in the bands, and highlight the interdependence of mechanical deformation and chemical diagenetic processes in deformation bands.

  3. JPRS Report, Science & Technology. USSR: Science & Technology Policy

    DTIC Science & Technology

    1989-10-23

    Soviet Programmers Form Joint Venture with Olivetti; Scientist Debate Reoccupation of Chernobyl Radiation Zones; Effect of Cost Accounting on Scientific Research; Lithuanian State Prizes for S&T Awarded; and others.

  4. Asian/Pacific Joint Production Programme of Materials for Neo-Literates in Rural Areas Planning Meeting (Tokyo, Japan, March 4-5, 1991). Report.

    ERIC Educational Resources Information Center

    Asian Cultural Centre for UNESCO, Tokyo (Japan).

    This document reports on the 1991 Planning Meeting on Asian/Pacific Joint Production (AJP) Program of Materials for Neo-Literates in Rural Areas, the purpose of which was to discuss Asian Cultural Center for Unesco (ACCU) literacy programs to be carried out under regional cooperation. Opening addresses focused on the success of the cooperative…

  5. The European Union Joint Procurement Agreement for cross-border health threats: what is the potential for this new mechanism of health system collaboration?

    PubMed

    Azzopardi-Muscat, Natasha; Schroder-Bäck, Peter; Brand, Helmut

    2017-01-01

    The Joint Procurement Agreement (JPA) is an innovative instrument for multi-country procurement of medical countermeasures against cross-border health threats. This paper aims to assess its potential performance. A literature review was conducted to identify key features of successful joint procurement programmes. Documentary analysis and a key informants' interview were carried out to analyse the European Union (EU) JPA. Ownership, equity, transparency, stable central financing, standardisation, flexibility and gradual development were identified as important prerequisites for successful establishment of multi-country joint procurement programmes in the literature while security of supply, favourable prices, reduction of operational costs and administrative burden and creation of professional expert networks were identified as desirable outcomes. The EU JPA appears to fulfil the criteria of ownership, transparency, equity, flexibility and gradual development. Standardisation is only partly fulfilled and central EU level financing is not provided. Security of supply is an important outcome for all EU Member States (MS). Price savings, reduction in administrative burden and creation of professional networks may be particularly attractive for the smaller MS. The JPA has the potential to increase health system collaboration and efficiency at EU level provided that the incentives for sustained commitment of larger MS are sufficiently attractive.

  6. Leaching behaviour, mechanical and durability properties of mortar containing municipal incineration bottom ash

    NASA Astrophysics Data System (ADS)

    Morales Hernandez, Maria B.

    The review of municipal solid waste (MSW) management scheme has indicated that the amount of MSW sent to incineration plants will increase in the UK in coming years. Therefore, the amount of municipal solid waste incineration (MSWI) residues generated will increase significantly. MSWI residues are divided into MSWI fly ash (MSWI-FA) and MSWI bottom ash (MSWI-BA). MSWI-FA is classified as hazardous residue thereby requires special treatment before disposal. MSWI-BA is mostly disposed in landfill sites. MSWI-BA fraction with particle size diameter below approximately 2mm has low engineering properties and may have an adverse effect on the environment due to its high porosity, solubility and leachability of possible toxic compounds. This research programme has investigated new potential uses and leaching behaviour of mortar containing MSWI-BA with particle size diameters below 2.36mm. Fraction of MSWI-BA with particle size diameters (φ) below 2.36 mm (φ <2.36) was divided into different sub-fractions to evaluate their influence on compressive strength of concrete when used as partial replacement of cement or sand. MSWI-BA fraction with φ <212mum (fine fraction) and 212mum < φ2.36mm (coarse fraction) used as partial replacement of cement and sand respectively, showed higher compressive strength compared with the other fractions examined. In addition, replacing sand with the coarse fraction of MSWI-BA exhibited similar or higher strength than the reference mix. Examination of physical and chemical properties of the fine and coarse fractions of MSWI-BA unbound indicated that both fractions had potential to be used as replacement of cement or sand. However, the evaluation of their leaching behaviour suggested that they should be bound in cement-based systems to avoid leaching of potential toxic elements. Evaluation of physical, mechanical and sulfate resistance properties of mortars containing 15% of the fine fraction of MSWI-BA as a partial replacement of cement and 50% of the coarse fraction as partial replacement of sand indicated potential uses in concrete production. In addition, the leachability of mortar specimens containing 15% and 50% of MSWI-BA as partial replacement of cement and sand respectively was significantly reduced when compared to unbound MSWI-BA fractions.

  7. Theoretical backgrounds of non-tempered materials production based on new raw materials

    NASA Astrophysics Data System (ADS)

    Lesovik, V. S.; Volodchenko, A. A.; Glagolev, E. S.; Chernysheva, N. V.; Lashina, I. V.; Feduk, R. S.

    2018-03-01

    One of the trends in construction material science is development and implementation of highly effective finish materials which improve architectural exterior of cities. Silicate materials widely-used in the construction today have rather low decorative properties. Different coloring agents are used in order to produce competitive materials, but due to the peculiarities of the production, process very strict specifications are applied to them. The use of industrial wastes or variety of rock materials as coloring agents is of great interest nowadays. The article shows that clay rock can be used as raw material in production of finish materials of non-autoclaved solidification. This raw material due to its material composition actively interacts with cementing component in steam treatment at 90–95 °C with formation of cementing joints that form a firm coagulative-cristalized and crystallization structure of material providing high physic-mechanical properties of silicate goods. It is determined that energy-saving, colored finish materials with compression strength up to 16 MPa can be produced from clay rocks.

  8. NEUTRON RADIOGRAPHY MEASUREMENT OF SALT SOLUTION ABSORPTION IN MORTAR

    PubMed Central

    Lucero, Catherine L.; Spragg, Robert P.; Bentz, Dale P.; Hussey, Daniel S.; Jacobson, David L.; Weiss, W. Jason

    2017-01-01

    Some concrete pavements in the US have recently exhibited premature joint deterioration. It is hypothesized that one component of this damage can be attributed to a reaction that occurs when salt-laden water is absorbed in the concrete and reacts with the matrix. This study examines the absorption of CaCl2 solution in mortar via neutron imaging. Mortar specimens were prepared with water to cement ratios, (w/c), of 0.36, 0.42 and 0.50 by mass and exposed to chloride solutions with concentrations ranging from 0 % to 29.8 % by mass. Depth of fluid penetration and moisture content along the specimen length were determined for 96 h after exposure. At high salt concentration (29.8 %), the sorption rate decreased by over 80 % in all samples. Along with changes in surface tension and viscosity, CaCl2 reacts with the cement paste to produce products (Friedel’s salt, Kuzel’s salt, or calcium oxychloride) that block pores and reduce absorption. PMID:28626299

  9. NEUTRON RADIOGRAPHY MEASUREMENT OF SALT SOLUTION ABSORPTION IN MORTAR.

    PubMed

    Lucero, Catherine L; Spragg, Robert P; Bentz, Dale P; Hussey, Daniel S; Jacobson, David L; Weiss, W Jason

    2017-01-01

    Some concrete pavements in the US have recently exhibited premature joint deterioration. It is hypothesized that one component of this damage can be attributed to a reaction that occurs when salt-laden water is absorbed in the concrete and reacts with the matrix. This study examines the absorption of CaCl 2 solution in mortar via neutron imaging. Mortar specimens were prepared with water to cement ratios, ( w/c ), of 0.36, 0.42 and 0.50 by mass and exposed to chloride solutions with concentrations ranging from 0 % to 29.8 % by mass. Depth of fluid penetration and moisture content along the specimen length were determined for 96 h after exposure. At high salt concentration (29.8 %), the sorption rate decreased by over 80 % in all samples. Along with changes in surface tension and viscosity, CaCl 2 reacts with the cement paste to produce products (Friedel's salt, Kuzel's salt, or calcium oxychloride) that block pores and reduce absorption.

  10. EBCOG Hospital Recognition: where do we stand?

    PubMed Central

    Wladimiroff, J.; Hornnes, P.

    2010-01-01

    Hospital Recognition for general Ob/Gyn training programmes was started by EBCOG (European Board & College of Obstetrics & Gynaecology) in 1996 and for subspecialty Ob/Gyn training programmes in 2005, the latter jointly with the four European scientific organisations representing the subspecialties. So far, 85 Audits/Visits have been conducted by EBCOG for general Ob/Gyn training and a good start has been made for subspecialty training, in particular Gynaecological Oncology. EBCOG Visits are conducted by two EBCOG representatives and one trainee appointed by ENTOG (European Network for Trainees in Obstetrics & Gynaecology) for general Ob/Gyn training programmes and by two subspecialty specialists and an EBCOG representative for subspecialty programmes. Each Visit lasts one day. Accredition is granted by the EBCOG Executive Board depending on the Visiting report. Ultimately, EBCOG would like to see the introduction of an auditing and accreditation system for general and subspecialty Ob/Gyn training programmes in each country in Europe PMID:25206968

  11. Can Arthroplasty Stem INfluence Outcome? (CASINO): a randomized controlled equivalence trial of 125 mm versus 150 mm Exeter V40 stems in total hip arthroplasty.

    PubMed

    Hamilton, David F; Ohly, Nicholas E; Gaston, Paul

    2018-04-16

    The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.

  12. Near-Surface Geologic Units Exposed Along Ares Vallis and in Adjacent Areas: A Potential Source of Sediment at the Mars Pathfinder Landing Site

    NASA Technical Reports Server (NTRS)

    Treiman, Allan H.

    1997-01-01

    A sequence of layers, bright and dark, is exposed on the walls of canyons, impact craters and mesas throughout the Ares Vallis region, Chryse Planitia, and Xanthe Terra, Mars. Four layers can be seen: two pairs of alternating dark and bright albedo. The upper dark layer forms the top surface of many walls and mesas. The upper dark-bright pair was stripped as a unit from many streamlined mesas and from the walls of Ares Valles, leaving a bench at the top of the lower dark layer, approximately 250 m below the highland surface on streamlined islands and on the walls of Ares Vallis itself. Along Ares Vallis, the scarp between the highlands surface and this bench is commonly angular in plan view (not smoothly curving), suggesting that erosion of the upper dark-bright pair of layers controlled by planes of weakness, like fractures or joints. These near-surface layers in the Ares Vallis area have similar thicknesses, colors, and resistances to erosion to layers exposed near the tops of walls in Valles Marineris (Treiman et al.) and may represent the same pedogenic hardpan units. From this correlation, and from analogies with hardpans on Earth, the light-color layers may be cemented by calcite or gypsum. The dark layers are likely cemented by an iron-bearing mineral. Mars Pathfinder instruments should permit recognition and useful analyses of hardpan fragments, provided that clean uncoated surfaces are accessible. Even in hardpan-cemented materials, it should be possible to determine the broad types of lithologies in the Martian highlands. However, detailed geochemical modeling of highland rocks and soils may be compromised by the presence of hardpan cement minerals.

  13. Tritium technology development in EEC laboratories contributions to design goals for NET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dinner, P.; Chazalon, M.; Leger, D.

    1988-09-01

    An overview is given of the tritium technology activities carried out in the European national laboratories associated with the European Fusion Programme and in the European Joint Research Center. The relationship of these activities to the Next European Torus (NET) design priorities is discussed, and the current status of the research is summarised. Future developments, required for NET, which will be addressed in the definition of the next 5-year programme are also presented.

  14. Interactive Courseware Standards

    DTIC Science & Technology

    1992-07-01

    music industry standard provides data formats and transmission specifications for musical notation. Joint Photographic Experts Group (JPEG). This...has been used in the music industry for several years, especially for electronically programmable keyboards and 16 instruments. The video compression

  15. Impact of online education on intern behaviour around joint commission national patient safety goals: a randomised trial.

    PubMed

    Shaw, Tim J; Pernar, Luise I; Peyre, Sarah E; Helfrick, John F; Vogelgesang, Kaitlin R; Graydon-Baker, Erin; Chretien, Yves; Brown, Elizabeth J; Nicholson, James C; Heit, Jeremy J; Co, John Patrick T; Gandhi, Tejal

    2012-10-01

    To compare the effectiveness of two types of online learning methodologies for improving the patient-safety behaviours mandated in the Joint Commission National Patient Safety Goals (NPSG). This randomised controlled trial was conducted in 2010 at Massachusetts General Hospital and Brigham and Women's Hospital (BWH) in Boston USA. Incoming interns were randomised to either receive an online Spaced Education (SE) programme consisting of cases and questions that reinforce over time, or a programme consisting of an online slide show followed by a quiz (SQ). The outcome measures included NPSG-knowledge improvement, NPSG-compliant behaviours in a simulation scenario, self-reported confidence in safety and quality, programme acceptability and programme relevance. Both online learning programmes improved knowledge retention. On four out of seven survey items measuring satisfaction and self-reported confidence, the proportion of SE interns responding positively was significantly higher (p<0.05) than the fraction of SQ interns. SE interns demonstrated a mean 4.79 (36.6%) NPSG-compliant behaviours (out of 13 total), while SQ interns completed a mean 4.17 (32.0%) (p=0.09). Among those in surgical fields, SE interns demonstrated a mean 5.67 (43.6%) NPSG-compliant behaviours, while SQ interns completed a mean 2.33 (17.9%) (p=0.015). Focus group data indicates that SE was more contextually relevant than SQ, and significantly more engaging. While both online methodologies improved knowledge surrounding the NPSG, SE was more contextually relevant to trainees and was engaging. SE impacted more significantly on both self-reported confidence and the behaviour of surgical residents in a simulated scenario.

  16. Compressive Strength Evaluation in Brazed ZrO2/Ti6Al4V Joints Using Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Sharma, Ashutosh; Kee, Se Ho; Jung, Flora; Heo, Yongku; Jung, Jae Pil

    2016-05-01

    This study aims to synthesize and evaluate the compressive strength of the ZrO2/Ti-6Al-4V joint brazed using an active metal filler Ag-Cu-Sn-Ti, and its application to dental implants assuring its reliability to resist the compressive failure in the actual oral environment. The brazing was performed at a temperature of 750 °C for 30 min in a vacuum furnace under 5 × 10-6 Torr atmosphere. The microstructure of the brazed joint showed the presence of an Ag-rich matrix and a Cu-rich phase, and Cu-Ti intermetallic compounds were observed along the Ti-6Al-4V bonded interface. The compressive strength of the brazed ZrO2/Ti-6Al-4V joint was measured by EN ISO 14801 standard test method. The measured compressive strength of the joint was ~1477 MPa—a value almost five times that of existing dental cements. Finite element analysis also confirmed the high von Mises stress values. The compressive strains in the samples were found concentrated near the Ti-6Al-4V position, matching with the position of the real fractured sample. These results suggest extremely significant compressive strength in ZrO2/Ti-6Al-4V joints using the Ag-Cu-Sn-Ti filler. It is believed that a highly reliable dental implant can be processed and designed using the results of this study.

  17. [Medical cooperation on the internet].

    PubMed

    Meier, N; Lenzen, H; Renger, B C

    1998-01-01

    Post-1999, the economically united EEC will pose new challenges to European business, industry and citizen. It is a key objective that in the domain of European "infostructure" these problems are challenged and overcome, and that "advanced communications technologies and services" (ACTS) become the cement which binds the Community together. Within ACTS, 130 different projects are building new services. The consortium Emerald develops a telemedicine platform, setting up teleworking with teleconference, computer supported co-operative work (cscw, joint editing), demonstration and teleteaching for radiology, cardiology, nuclear medicine and radio surgery working environments.

  18. Construction Productivity Advancement Research (CPAR) Program: Improved Materials and Processes for Sealing and Resealing Joints in Portland Cement Concrete Pavements - Field Evaluation

    DTIC Science & Technology

    1993-10-01

    sealant was determined by noting the type and number of defects each sealant incurred. Figure 4 provides a sample evaluation sheet used dur- ing the field...was conducted by visually inspect- ing the mater~al for defects . If any defects were noted, the type of defect was described and the quant~ty of that... defect was measured. The quantity of the defect was dividted by the total quantity of sealant and the result reported as percent defect . Adhesion and

  19. Science Education and Public Outreach in Asia - experiences in ACCENT

    NASA Astrophysics Data System (ADS)

    Schuepbach, E.

    2006-12-01

    ACCENT is the European Network of Excellence in Atmospheric Composition Change (www.accent- network.org). Its Task Training and Education aims at disseminating ACCENT results to a variety of target groups, including emerging countries. Until now, fellowships have been offered for early-career scientists to participate in European science training events. A teacher training workshop has concentrated on cross- cultural aspects of PhD supervision. The involvement of new Associated Partners from Asia has triggered reflections on science education and outreach to politicians and the public in this part of the world. Joint educational and outreach programmes and products are currently developed with China and Mongolia for training activities scheduled in autumn 2006 and autumn 2007. First experiences in joint science education programmes for early-career scientists will be presented, and the challenges associated with communicating science to non-scientists in Asia will be discussed.

  20. [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

    PubMed

    Thomas, P; Schuh, A; Ring, J; Thomsen, M

    2008-03-01

    Materials used in osteosynthesis or artificial joint replacement are usually well tolerated. Complaints after such operations are mostly related to infection or mechanical problems but may also be caused by allergic reactions. The latter encompass skin changes, e.g., eczema, delayed wound/bone healing, recurrent effusion, pain, or implant loosening. In contrast to the high incidence of cutaneous metal contact allergy, allergies associated with implants are a rare condition. However, epidemiological data on the incidence of implant-related allergic reactions are still missing. Typical elicitors are nickel, chromium, cobalt, and constituents of bone cement (acrylates und additives such as gentamicin or benzoyl peroxide). After exclusion of the most common differential diagnoses, allergy diagnostic procedures are primarily based on patch tests including a metal and bone cement component series. Additional analysis of periimplant tissue is recommended. However, further studies are necessary to show the significance of the histologic findings and the role of the lymphocyte transformation test (LTT). Which combinations of factors will induce allergic sensitization to implants or trigger periimplant allergic reactions in the case of preexisting cutaneous metal allergy is still unknown. Titanium-based osteosynthesis materials are recommended for metal allergic patients. In elective hip replacements, a ceramic/polyethylene (PE) articulation should be used, and in knee replacements "alternative materials". If a regular, potentially applicable CoCr/PE articulation is preferred, the patient must be well informed and must give his/her written consent.

  1. Why is joint attention a pivotal skill in autism?

    PubMed Central

    Charman, Tony

    2003-01-01

    Joint attention abilities play a crucial role in the development of autism. Impairments in joint attention are among the earliest signs of the disorder and joint attention skills relate to outcome, both in the 'natural course' of autism and through being targeted in early intervention programmes. In the current study, concurrent and longitudinal associations between joint attention and other social communication abilities measured in a sample of infants with autism and related pervasive developmental disorders at age 20 months, and language and symptom severity at age 42 months, were examined. Extending the findings from previous studies, joint attention ability was positively associated with language gains and (lower) social and communication symptoms, and imitation ability was also positively associated with later language. Some specificity in the association between different aspects of joint attention behaviours and outcome was found: declarative, triadic gaze switching predicted language and symptom severity but imperative, dyadic eye contact behaviours did not. Further, although joint attention was associated with later social and language symptoms it was unrelated to repetitive and stereotyped symptoms, suggesting the latter may have a separate developmental trajectory. Possible deficits in psychological and neurological processes that might underlie the impaired development of joint attention in autism are discussed. PMID:12639329

  2. The ESA contribution to the European Satellite Navigation Programme

    NASA Astrophysics Data System (ADS)

    Lucas, R.; Lo Galbo, P.; de Mateo, M. L.; Steciw, A.; Ashford, E.

    1996-02-01

    This paper describes the ESA ARTES-9 programme on Global Navigation Satellite Systems (GNSS). This programme will be the ESA contribution to the wider European Satellite Navigation Programme which is to be implemented as a joint effort of the European Union, Eurocontrol and ESA with the support of other European bodies such as telecommunication operators, national civil aviation authorities, national space agencies, industry, universities and R&D institutes in general. In fact, in view of the geographical area concerned, the large number of parties interested, the experience required and the global nature of GNSS, the proposed initiative can only be successful if based on a strong cooperation at a European and international scale. The ESA ARTES-9 programme will consist on one side, of the design, development and validation of the European complement to the GPS and GLONASS systems (GNSS1), and on the other side of the study, design and pre-development of the European contribution to follow-on systems: GNSS2.

  3. [Effect of saliva contamination on microleakage around class-5 cavities restored with three different types of adhesive materials].

    PubMed

    Iovan, Gianina; Stoleriu, Simona; Andrian, S; Dia, V; Căruntu, Irina Draga

    2004-01-01

    The recent improvement of adhesive materials should decrease the risk related to saliva contamination. The aim of this study was to evaluate the effect of saliva contamination on the microleakage within class V cavities restored with three different types of materials: conventional glass ionomer cement, composite resin and compomer. 30 human extracted teeth were randomly divided in 3 equal groups. In each group, class V cavities were prepared on both facial and lingual surfaces (but joint for glass ionomer cement and bevelled incisal margin for composite resin and compomer). The lingual cavities were contaminated with saliva prior to restoration, while the facial cavities were not contaminated, serving as control. After water storage for 24 hours, teeth were immersed in 1% methylene blue solution for 24 hours. The axial sections were viewed under an optical microscope and the extent of dye penetration along cervical, axial and incisal margins was measured in millimetres. Statistic analysis showed that under salivary contamination, microleakage increased along the cervical margin of restoration for all three tested materials. Saliva contamination resulted in microleakage within the axial wall of the cavity only for the conventional glass ionomer cement. These data indicate that composite resin and compomer used together with new adhesives seem to be less sensitive to saliva contamination compared to conventional materials. However, under saliva contamination, cervical microleakage cannot be completely prevented and proper isolation should still be mandatory.

  4. A synopsis of the Joint Environment and Human Health Programme in the UK.

    PubMed

    Moore, Michael N; Kempton, Pamela D

    2009-12-21

    The Joint Environment and Human Health (E&HH) Programme has explored how both man-made and natural changes to the environment can influence human health. Scientists have tackled the complicated mix of environmental, social and economic factors that influence health, particularly focusing on naturally occurring toxins, man-made pollutants, nanoparticles and pathogens to see:* how they spread within the environment* how their properties change as they interact with other substances or organisms* how we become exposed to them, and* their impact on human health.The Programme has not only succeeded in bringing together scientists from a broad range of environmental, social and biomedical backgrounds, but also fostered new relationships with end users and policy makers. This new community is helping to provide the multidisciplinary capacity able to respond in an interdisciplinary way to resolve problems that are intrinsically interfacial in character. Many of these questions relate to complex issues such as the environmental biology and geochemistry of soils and how these influence the transport, accessibility and bioavailability of chemical pollutants and infectivity of pathogens. The dispersion of harmful particles in the atmosphere is another area of major concern where the E&HH Programme has broken new ground by showing how the chemical and physical properties of such particles influence their environmental behaviour and may govern their toxicity and resultant pathological reactions induced following inhalation. Working groups and networks have identified potential health problems concerning the transport and emergence of human pathogens associated with food, soil, air and water. The consequence(s) of global and regional climate change for the environmental behaviours of pollutants and pathogens have been considered by a number of the projects supported by the E&HH programme.The selection of articles in this supplement reflect the broad scope of the E&HH programme. By effectively identifying and interconnecting these interdisciplinary elements, the E&HH programme has fostered the emergence of new ways of solving problems in areas of research that have, until recently, had little connection with one another. This has not only helped build new research groupings, but has also led to exciting new scientific developments as described in this issue of Environmental Health.

  5. Transforming research for food and health in Europe.

    PubMed

    McCarthy, M

    2012-10-01

    Eating causes up to a quarter of premature deaths from chronic diseases in Europe through poor diet and excess consumption. FAHRE (Food and Health Research in Europe) was funded to determine needs and gaps in research structures and programmes. Most food research links towards agriculture and the environmental sciences, whereas most health research links towards clinical diseases, biochemical pathways and biology. Research on food and health together includes food safety research addressing biological and chemical contaminants, and biotechnology research supporting clinical nutrition. Research for healthy eating must draw on social and behavioural sciences for studies of policy, regulation and interventions. The food industry, across production, retail and catering, must be part of the research programme, and civil society. Better coordination and improved levels of funding are needed in the coming European research programme 'Horizon 2020', and national programmes linked in the Joint Programming Initiative. Transforming the research agenda can give great benefits to Europe's citizens.

  6. International treatment access and research, how you can help--interview with Dr. Peter Piot of UNAIDS. Joint United Nations Programme on HIV/AIDS. Interview by John S. James.

    PubMed

    Piot, P

    1996-11-01

    Medical advances in the United States have greatly increased the lifespan of people with AIDS, but there is no access to modern medicine for the 90 percent of AIDS patients who live in other countries. Dr. Peter Piot of the United Nations Programme on HIV/AIDS (UNAIDS) addresses the efforts of six U.N. agencies in improving treatment access throughout the world and improving research on natural and traditional medicines.

  7. The path to fusion power†

    PubMed Central

    Smith, Chris Llewellyn; Cowley, Steve

    2010-01-01

    The promise, status and challenges of developing fusion power are outlined. The key physics and engineering principles are described and recent progress quantified. As the successful demonstration of 16 MW of fusion in 1997 in the Joint European Torus showed, fusion works. The central issue is therefore to make it work reliably and economically on the scale of a power station. We argue that to meet this challenge in 30 years we must follow the aggressive programme known as the ‘Fast Track to Fusion’. This programme is described in some detail. PMID:20123748

  8. A modelling approach to vaccination and contraception programmes for rabies control in fox populations.

    PubMed Central

    Suppo, C; Naulin, J M; Langlais, M; Artois, M

    2000-01-01

    In a previous study, three of the authors designed a one-dimensional model to simulate the propagation of rabies within a growing fox population; the influence of various parameters on the epidemic model was studied, including oral-vaccination programmes. In this work, a two-dimensional model of a fox population having either an exponential or a logistic growth pattern was considered. Using numerical simulations, the efficiencies of two prophylactic methods (fox contraception and vaccination against rabies) were assessed, used either separately or jointly. It was concluded that far lower rates of administration are necessary to eradicate rabies, and that the undesirable side-effects of each programme disappear, when both are used together. PMID:11007334

  9. Friendship and money: A qualitative study of service users' experiences of participating in a supported socialisation programme.

    PubMed

    Sheridan, Ann; O'Keeffe, Donal; Coughlan, Barbara; Frazer, Kate; Drennan, Johnathan; Kemple, Mary

    2018-06-01

    Social opportunities can be limited in the lives of people with enduring mental illness (EMI) due to psychiatric stigma, restricted home environments and employment barriers. Supported socialisation programmes have the potential to redress the impact of social isolation. To explore the experiences of service users with EMI taking part in a supported socialisation programme, using written diary entries. This article reports on the qualitative component of a randomised controlled trial of supported socialisation for people with EMI (published previously in this journal). Trial participation involved (1) being matched with a volunteer partner and engaging in social/leisure activities while receiving a stipend of €20 or (2) receiving this stipend only and engaging in self-driven socialisation. Participants completed written diaries documenting their perspectives on their experiences of supported socialisation. Data were analysed using Thematic Analysis. Experiences of participation were characterised by involvement 'normalising' life, fostering a sense of connectedness, improving physical health, and facilitating engagement with culture. Taking part helped participants integrate socialising into their identity, enhanced their perceived capacity to be social, and cemented/expanded social networks. Participants also experienced significant obstacles to socialisation. Supported socialisation can increase confidence, social competence and self-agency; buffer against psychiatric stigma; build social capital; and afford opportunities to enhance social integration, inclusion and belonging.

  10. The effect of sodium chloride on the dissolution of calcium silicate hydrate gels.

    PubMed

    Hill, J; Harris, A W; Manning, M; Chambers, A; Swanton, S W

    2006-01-01

    The use of cement based materials will be widespread in the long-term management of radioactive materials in the United Kingdom. One of the applications could be the Nirex reference vault backfill (NRVB) as an engineered barrier within a deep geological repository. NRVB confers alkaline conditions, which would provide a robust chemical barrier through the control of the solubility of some key radionuclides, enhanced sorption and minimised corrosion of steel containers. An understanding of the dissolution of C-S-H gels in cement under the appropriate conditions (e.g., saline groundwaters) is necessary to demonstrate the expected evolution of the chemistry over time and to provide sufficient cement to buffer the porewater conditions for the required time. A programme of experimental work has been undertaken to investigate C-S-H gel dissolution behaviour in sodium chloride solutions and the effect of calcium/silicon ratio (C/S), temperature and cation type on this behaviour. Reductions in calcium concentration and pH values were observed with samples equilibrated at 45 degrees C compared to those prepared at 25 degrees C. The effect of salt cation type on salt-concentration dependence of the dissolution of C-S-H gels was investigated by the addition of lithium or potassium chloride in place of sodium chloride for gels with a C/S of 1.0 and 1.8. With a C/S of 1.0, similar increases in dissolved calcium concentration with increasing ionic strength were recorded for the different salts. However, at a C/S of 1.8, anomalously high calcium concentrations were observed in the presence of lithium.

  11. Towards computer-assisted surgery in shoulder joint replacement

    NASA Astrophysics Data System (ADS)

    Valstar, Edward R.; Botha, Charl P.; van der Glas, Marjolein; Rozing, Piet M.; van der Helm, Frans C. T.; Post, Frits H.; Vossepoel, Albert M.

    A research programme that aims to improve the state of the art in shoulder joint replacement surgery has been initiated at the Delft University of Technology. Development of improved endoprostheses for the upper extremities (DIPEX), as this effort is called, is a clinically driven multidisciplinary programme consisting of many contributory aspects. A part of this research programme focuses on the pre-operative planning and per-operative guidance issues. The ultimate goal of this part of the DIPEX project is to create a surgical support infrastructure that can be used to predict the optimal surgical protocol and can assist with the selection of the most suitable endoprosthesis for a particular patient. In the pre-operative planning phase, advanced biomechanical models of the endoprosthesis fixation and the musculo-skeletal system of the shoulder will be incorporated, which are adjusted to the individual's morphology. Subsequently, the support infrastructure must assist the surgeon during the operation in executing his surgical plan. In the per-operative phase, the chosen optimal position of the endoprosthesis can be realised using camera-assisted tools or mechanical guidance tools. In this article, the pathway towards the desired surgical support infrastructure is described. Furthermore, we discuss the pre-operative planning phase and the per-operative guidance phase, the initial work performed, and finally, possible approaches for improving prosthesis placement.

  12. No difference in joint awareness after mobile- and fixed-bearing total knee arthroplasty: 3-year follow-up of a randomized controlled trial.

    PubMed

    Schotanus, M G M; Pilot, P; Vos, R; Kort, N P

    2017-12-01

    To compare the patients ability to forget the artificial knee joint in everyday life who were randomized to be operated for mobile- or fixed-bearing total knee arthroplasty (TKA). This single-center randomized controlled trial evaluated the 3-year follow-up of the cemented mobile- and fixed-bearing TKA from the same brand in a series of 41 patients. Clinical examination was during the pre-, 6-week, 6-month, 1-, 2- and 3-year follow-up containing multiple patient-reported outcome measures (PROMs) including the 12-item Forgotten Joint Score (FJS-12) at 3 years. Effect size was calculated for each PROM at 3-year follow-up to quantify the size of the difference between both bearings. At 3-year follow-up, general linear mixed model analysis showed that there were no significant or clinically relevant differences between the two groups for all outcome measures. Calculated effect sizes were small (<0.3) for all the PROMs except for the FJS-12; these were moderate (0.5). The results of this study demonstrate that joint awareness was slightly lower in patients operated with the MB TKA with comparable improved clinical outcome and PROMs at 3-year follow-up. Measuring joint awareness with the FJS-12 is useful and provides more stringent information at 3-year follow-up compared to other PROMs and should be the PROM of choice at each follow-up after TKA. Level I, randomized controlled trial.

  13. Outreach programmes to attract girls into computing: how the best laid plans can sometimes fail

    NASA Astrophysics Data System (ADS)

    Lang, Catherine; Fisher, Julie; Craig, Annemieke; Forgasz, Helen

    2015-07-01

    This article presents a reflective analysis of an outreach programme called the Digital Divas Club. This curriculum-based programme was delivered in Australian schools with the aim of stimulating junior and middle school girls' interest in computing courses and careers. We believed that we had developed a strong intervention programme based on previous literature and our collective knowledge and experiences. While it was coordinated by university academics, the programme content was jointly created and modified by practicing school teachers. After four years, when the final data were compiled, it showed that our programme produced significant change to student confidence in computing, but the ability to influence a desire to pursue a career path in computing did not fully eventuate. To gain a deeper insight in to why this may be the case, data collected from two of the schools are interrogated in more detail as described in this article. These schools were at the end of the expected programme outcomes. We found that despite designing a programme that delivered a multi-layered positive computing experience, factors beyond our control such as school culture and teacher technical self-efficacy help account for the unanticipated results. Despite our best laid plans, the expectations that this semester long programme would influence students' longer term career outcomes may have been aspirational at best.

  14. Programmable motion of DNA origami mechanisms.

    PubMed

    Marras, Alexander E; Zhou, Lifeng; Su, Hai-Jun; Castro, Carlos E

    2015-01-20

    DNA origami enables the precise fabrication of nanoscale geometries. We demonstrate an approach to engineer complex and reversible motion of nanoscale DNA origami machine elements. We first design, fabricate, and characterize the mechanical behavior of flexible DNA origami rotational and linear joints that integrate stiff double-stranded DNA components and flexible single-stranded DNA components to constrain motion along a single degree of freedom and demonstrate the ability to tune the flexibility and range of motion. Multiple joints with simple 1D motion were then integrated into higher order mechanisms. One mechanism is a crank-slider that couples rotational and linear motion, and the other is a Bennett linkage that moves between a compacted bundle and an expanded frame configuration with a constrained 3D motion path. Finally, we demonstrate distributed actuation of the linkage using DNA input strands to achieve reversible conformational changes of the entire structure on ∼ minute timescales. Our results demonstrate programmable motion of 2D and 3D DNA origami mechanisms constructed following a macroscopic machine design approach.

  15. Programmable motion of DNA origami mechanisms

    PubMed Central

    Marras, Alexander E.; Zhou, Lifeng; Su, Hai-Jun; Castro, Carlos E.

    2015-01-01

    DNA origami enables the precise fabrication of nanoscale geometries. We demonstrate an approach to engineer complex and reversible motion of nanoscale DNA origami machine elements. We first design, fabricate, and characterize the mechanical behavior of flexible DNA origami rotational and linear joints that integrate stiff double-stranded DNA components and flexible single-stranded DNA components to constrain motion along a single degree of freedom and demonstrate the ability to tune the flexibility and range of motion. Multiple joints with simple 1D motion were then integrated into higher order mechanisms. One mechanism is a crank–slider that couples rotational and linear motion, and the other is a Bennett linkage that moves between a compacted bundle and an expanded frame configuration with a constrained 3D motion path. Finally, we demonstrate distributed actuation of the linkage using DNA input strands to achieve reversible conformational changes of the entire structure on ∼minute timescales. Our results demonstrate programmable motion of 2D and 3D DNA origami mechanisms constructed following a macroscopic machine design approach. PMID:25561550

  16. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].

    PubMed

    Kovanda, M; Havlícek, V; Hudec, J

    2009-04-01

    PURPOSE OF THE STUDY The mid-term longevity of femoral components varies considerably, with some showing failure due to early aseptic loosening. Since the hip joint is subject to heavy mechanical loads, it can be assumed that the mechanical interaction of the implant, bone cement and femur will play a key role in the resultant reliability of an arthroplasty. This study was designed to examine this mechanical interaction in four femoral components different in construction (Poldi-Cech, CF-30, MS-30 and PFC) using mathematical simulation. MATERIAL AND METHODS Four stem/cement/femur 3-D mathematical models, comparable in quality, infolving the Poldi-Cech, CF-30, MS-30 and PFC stems, respectively, were constructed. A 3-D model for each stem was created according to its real, middle-size femoral component. Each 3-D model of the cement mantle corresponded in shape to the mantle of the appropriate real stem, with its thickness based on the recommended values of 4-7 mm in the proximal and 1-3 mm in the distal part, and with the cement mantle reaching as far as 10 mm distal to the femoral stem tip. For simplicitys sake the outer surface of the cement mantle was simulated as smooth. A 3-D model involving the proximal epiphysis and the metaphysis of a femur was reconstructed, based on a series of CT cross-sections obtained periodically at 10.5-mm and 2.5-mm distances. The sten/cement/femur model with the MS-30 stem also included a centraliser. The mechanical interaction of the stem, bone cement and bone tissue was examined by means of mathematical stimulation using ANSYS 5.7 software based on finite element analysis. RESULTS For the sake of simplicity, only two key parameters are presented, namely, contact stress at the stem-cement interface and equivalent deformation in the stem/cement/femur system. The least satisfactory stress loading was in the CF-30 stem whose sharp edges showed the values of contact stress about six-times higher than on the mid-medial portion of the stem, with the sharp edges behaving as stress concentrators. A satisfactory stress loading was found in Poldi-Cech, MS-30 and PFC stems, in which contact stress was evenly distributed along the whole lenght of the stem and the values at the edges and on the midmedial portion did not differ much. DISCUSSION The distribution of contact stress is one of the most important factors for the long-term longevity of implants. It was found least satisfactory in the CF-30 stem whose sharp edges act as stress condenser adversely affecting not only the stemcement interface, but also the resultant stress distribution within the femur. The most satisfactory results of stress distribution were recorded in the Poldi-Cech and MS-30 stems. The PFC stem also responded satisfactorily to the simulated stress loading. However, on loading whose substantial part would be torsion, the stems circular or oval cross-section could interfere with rotation stability of the implant; but this was impossible to detect by the mathematical simulation used in this study. CONCLUSIONS The results presented here show that, in the Poldi-Cech, CF-30, MS-30 and PFC femoral stems, a good agreement was achieved between the results of their clinical application and those of mathematical modelling of their mechanical properties. It can be concluded that mechanical interaction among the femoral stem, cement mantle and bone tissue plays the key role in the long-term longevity of such an implant. Key words: Poldi-Cech, CF-30, MS-30, PFC, mechanical interaction, contact stress.

  17. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up.

    PubMed

    Flivik, G; Kristiansson, I; Ryd, L

    2015-01-01

    We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement-bone interface in order to maximise acetabular component stability and longevity. ©2015 The British Editorial Society of Bone & Joint Surgery.

  18. Antibiotic stability over six weeks in aqueous solution at body temperature with and without heat treatment that mimics the curing of bone cement

    PubMed Central

    Samara, E.; Decosterd, L. A.; Richards, R. G.; Gautier, E.; Wahl, P.

    2017-01-01

    Objectives Thermal stability is a key property in determining the suitability of an antibiotic agent for local application in the treatment of orthopaedic infections. Despite the fact that long-term therapy is a stated goal of novel local delivery carriers, data describing thermal stability over a long period are scarce, and studies that avoid interference from specific carrier materials are absent from the orthopaedic literature. Methods In this study, a total of 38 frequently used antibiotic agents were maintained at 37°C in saline solution, and degradation and antibacterial activity assessed over six weeks. The impact of an initial supplementary heat exposure mimicking exothermically curing bone cement was also tested as this material is commonly used as a local delivery vehicle. Antibiotic degradation was assessed by liquid chromatography coupled to mass spectrometry, or by immunoassays, as appropriate. Antibacterial activity over time was determined by the Kirby-Bauer disk diffusion assay. Results The heat exposure mimicking curing bone cement had minimal effect on stability for most antibiotics, except for gentamicin which experienced approximately 25% degradation as measured by immunoassay. Beta-lactam antibiotics were found to degrade quite rapidly at 37°C regardless of whether there was an initial heat exposure. Excellent long-term stability was observed for aminoglycosides, glycopeptides, tetracyclines and quinolones under both conditions. Conclusions This study provides a valuable dataset for orthopaedic surgeons considering local application of antibiotics, and for material scientists looking to develop next-generation controlled or extended-release antibiotic carriers. Cite this article: E. Samara, T. F. Moriarty, L. A. Decosterd, R. G. Richards, E. Gautier, P. Wahl. Antibiotic stability over six weeks in aqueous solution at body temperature with and without heat treatment that mimics the curing of bone cement. Bone Joint J 2017;6:296–306. DOI: 10.1302/2046-3758.65.BJR-2017-0276.R1. PMID:28515059

  19. Sacroplasty for symptomatic sacral hemangioma: a novel treatment approach. A case report.

    PubMed

    Agarwal, V; Sreedher, G; Weiss, K R; Hughes, M A

    2013-06-01

    Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications.

  20. Sacroplasty for Symptomatic Sacral Hemangioma: A Novel Treatment Approach

    PubMed Central

    Agarwal, V.; Sreedher, G.; Weiss, K.R.; Hughes, M.A.

    2013-01-01

    Summary Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications. PMID:23693051

  1. Rock cities, periglacial mass-wasting, and honeycomb weathering in Warren County, northwestern Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inners, J.D.; Sevon, W.D.; Moore, M.E.

    1993-03-01

    Imposing hilltop rock-cities developed from widely jointed outcrops of Olean conglomerate (Lower Pennsylvanian) create picturesque scenery on the Allegheny High Plateau in Warren Co., Pa. At least six such rock cities 2 to 5 acres in extent are associated with the Late Wisconsinan glacial border in the northern half of the county. Farther to the south, jumbled Olean and Knapp (Lower Mississippian) joint blocks occur on steep slopes below valley-wall cliffs. The rock cities and accumulations of displaced joint blocks are largely relics of Late Wisconsinan periglacial mass-wasting. Frost splitting initiated opening of bedrock joints to form buildings. Gravity, soilmore » wedging, and possibly gelifluction then widened the fissures into streets. Gelifluction moved blocks downslope and oriented their long axes parallel with slope (Warren Rocks). Forward toppling of high, unstable blocks contributed to mass-movement on some steep slopes (Rimrock). Today, rock cities and downslope blocks are stable in areas of gentle (less than 10 percent) slopes, but toppling, solifluction, creep, and debris flows cause continued slow movement of large blocks on moderately steep to steep (greater than 30 percent) slopes. Blocks of Olean and Knapp conglomerate have both stratabound pitting and intricate honeycomb weathering. Deep pitting is controlled largely by variations in silica cementation. Honeycomb weathering is most evident in sandy layers and results from patterns of iron-oxide impregnation. Both are Holocene surface-weathering processes.« less

  2. Allergies in orthopaedic and trauma surgery.

    PubMed

    Lohmann, C H; Hameister, R; Singh, G

    2017-02-01

    Hypersensitivity reactions to implants in orthopaedic and trauma surgery are a rare but devastating complication. They are considered as a delayed-type of hypersensitivity reaction (type IV), characterized by an antigen activation of sensitized T-lymphocytes releasing various cytokines and may result in osteoclast activation and bone resorption. Potential haptens are originated from metal alloys or bone-cement. A meta-analysis has confirmed a higher probability of developing a metal hypersensitivity postoperatively and noted a greater risk of failed replacements compared to stable implants. Hypersensitivity to implants may present with a variety of symptoms such as pain, joint effusion, delayed wound/bone healing, persistent secretion, allergic dermatitis (localized or systemic), clicking noises, loss of joint function, instability and failure of the implant. Various diagnostic options have been offered, including patch testing, metal alloy patch testing, histology, lymphocyte transformation test (LTT), memory lymphocyte immunostimulation assay (MELISA), leukocyte migration inhibition test (LIF) and lymphocyte activation test (LAT). No significant differences between in vivo and in vitro methods have been found. Due to unconvincing evidence for screening methods, predictive tests are not recommended for routine performance. Infectious aetiology always needs to be excluded. As there is a lack of evidence on large-scale studies with regards to the optimal treatment option, management currently relies on individual case-by-case decisions. Several options for patients with (suspected) metal-related hypersensitivity exist and may include materials based on ceramic, titanium or oxinium or modified surfaces. Promising results have been reported, but long-term experience is lacking. More large-scaled studies are needed in this context. In patients with bone-cement hypersensitivity, the component suspected for hypersensitivity should be avoided. The development of (predictive) biomarkers is considered as a major contribution for the future. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. In-Hospital Acute Kidney Injury After TKA Revision With Placement of an Antibiotic Cement Spacer.

    PubMed

    Berliner, Zachary P; Mo, Andrew Z; Porter, David A; Grossman, Jamie M; Hepinstall, Matthew S; Cooper, H John; Scuderi, Giles R

    2018-07-01

    There is mounting evidence that treatment of periprosthetic joint infection of the knee with an antibiotic cement spacer (ACS) may increase risk for acute kidney injury (AKI). We sought to determine the incidence, as well as potential risk factors, of in-hospital AKI in this cohort. We retrospectively identified 75 patients that received either a static or articulating ACS at a single institution. In-hospital AKI was defined by a more than 50% rise in serum creatinine from preoperative baseline to at least 1.4 mg/dL. Our secondary outcome was percent change in creatinine from preoperative to peak postoperative value. Variables were analyzed for the outcome of AKI with univariate logistic regression. A final multivariate model for percent change in creatinine was formed while controlling for age, gender, body mass index, and baseline creatinine. The incidence of AKI was 14.6%, occurring at a mean of 6.3 days (2-8 days). A lower preoperative hemoglobin (odds ratio = 1.82, P = .015) significantly increased risk for AKI on univariate analysis. Diagnosis of either hypertension or diabetes also showed a strong statistical trend (P = .056). On multivariate regression, lower preoperative hemoglobin significantly correlated with a greater percent rise in creatinine postoperatively (β = 0.30, P = .015). The incidence of AKI in patients who receive ACS is relatively high, raising clinical concern in the care of periprosthetic joint infection patients. Our results suggest that a lower baseline hemoglobin may be involved in the etiology of AKI in this population. Therefore, it may be clinically appropriate to monitor anemic patients for AKI when implanting an ACS. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Selected Heat-Sensitive Antibiotics Are Not Inactivated During Polymethylmethacrylate Curing and Can Be Used in Cement Spacers for Periprosthetic Joint Infection.

    PubMed

    Carli, Alberto V; Sethuraman, Arvinth S; Bhimani, Samrath J; Ross, Frederick P; Bostrom, Mathias P G

    2018-06-01

    Antibiotic use in polymethylmethacrylate (PMMA) spacers has historically been limited to those which are "heat-stable" and thus retain their antimicrobial properties after exposure to the high temperatures which occur during PMMA curing. This study examines the requirement of "heat stability" by measuring temperatures of Palacos and Simplex PMMA as they cure inside commercial silicone molds of the distal femur and proximal tibia. Temperature probes attached to thermocouples were placed at various depths inside the molds and temperatures were recorded for 20 minutes after PMMA introduced and a temperature curve for each PMMA product was determined. A "heat-stable" antibiotic, vancomycin, and a "heat-sensitive" antibiotic, ceftazidime, were placed in a programmable thermocycler and exposed to the same profile of PMMA curing temperatures. Antimicrobial activity against Staphylococcus aureus was compared for heat-treated antibiotics vs room temperature controls. Peak PMMA temperatures were significantly higher in tibial (115.2°C) vs femoral (85.1°C; P < .001) spacers. In the hottest spacers, temperatures exceeded 100°C for 3 minutes. Simplex PMMA produced significantly higher temperatures (P < .05) compared with Palacos. Vancomycin bioactivity did not change against S aureus with heat exposure. Ceftazidime bioactivity did not change when exposed to femoral temperature profiles and was reduced only 2-fold with tibial profiles. The curing temperatures of PMMA in knee spacers are not high enough or maintained long enough to significantly affect the antimicrobial efficacy of ceftazidime, a known "heat-sensitive" antibiotic. Future studies should investigate if more "heat-sensitive" antibiotics could be used clinically in PMMA spacers. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. SOLAR PASTEURIZER WITH INTEGRAL HEAT EXCHANGER FOR TREATING WATER IN RURAL AREAS

    EPA Science Inventory

    According to the WHO/UNICEF Joint Monitoring Programme for Water Supply and Sanitation there are currently 1.1 billion people without access to safe water on the planet. Every year more than five million people die from the lack of safe water and improper sanitation. Child...

  6. How To Prepare Materials for Neo-Literates. Literacy Lessons.

    ERIC Educational Resources Information Center

    Sasaoka, Taichi

    Literacy materials are either for illiterate people or for neoliterate people (those who have attained limited literacy but might easily relapse if they do not practice reading with appropriate materials). Thirty-five kinds of prototype materials for neoliterate persons have been developed by the Asian/Pacific Joint Production Programme of…

  7. An Eastern Paradigm of Evaluation

    ERIC Educational Resources Information Center

    Russon, Craig

    2008-01-01

    Teaching on the philosophies of evaluation as part of a pilot introductory course of a new diploma programme jointly sponsored by the United Nations (UN) Evaluation Group and the United Nations Staff College, the author compared and contrasted the "rationalistic" paradigm with the "naturalistic" paradigm on the basis of ontology, epistemology, and…

  8. Accelerating Early Language Development with Multi-Sensory Training

    ERIC Educational Resources Information Center

    Bjorn, Piia M.; Kakkuri, Irma; Karvonen, Pirkko; Leppanen, Paavo H. T.

    2012-01-01

    This paper reports the outcome of a multi-sensory intervention on infant language skills. A programme titled "Rhyming Game and Exercise Club", which included kinaesthetic-tactile mother-child rhyming games performed in natural joint attention situations, was intended to accelerate Finnish six- to eight-month-old infants' language development. The…

  9. Reframing European Doctoral Training for the New ERA

    ERIC Educational Resources Information Center

    Repeckaite, Daiva

    2016-01-01

    In 2014 the institutionalization of European higher education and training, as well as research and innovation, policy entered a new phase: a number of financial instruments were simplified and merged. The Erasmus Mundus programme, wherein consortia of European and overseas universities built joint master's or doctoral degrees, was split into two…

  10. Engaging Employers in Apprenticeship Opportunities: Making It Happen Locally

    ERIC Educational Resources Information Center

    OECD Publishing, 2017

    2017-01-01

    This joint OECD-ILO publication provides guidance on how local and regional governments can foster business-education partnerships in apprenticeship programmes and other types of work-based learning, drawing on case studies across nine countries. There has been increasing interest in apprenticeships which combine on the job training with…

  11. Providing for the Future: Providers' Views on Apprenticeship Reform

    ERIC Educational Resources Information Center

    McCrone, Tami; Sims, David; Gladding, Cath

    2016-01-01

    Apprenticeships are currently undergoing reform in England. Funding mechanisms and the content of Apprenticeship programmes are being restructured. NFER and the Association of Employment and Learning Providers (AELP) have carried out a joint research project to inform future policy and practice with evidence on how providers of Apprenticeships are…

  12. Critical interactions between Global Fund-supported programmes and health systems: a case study in Indonesia.

    PubMed

    Desai, Monica; Rudge, James W; Adisasmito, Wiku; Mounier-Jack, Sandra; Coker, Richard

    2010-11-01

    The Global Fund to Fight AIDS, Tuberculosis and Malaria has played an important role in financing the response to HIV/AIDS and tuberculosis (TB) in Indonesia. As part of a series of case studies, we assessed the nature and extent of integration of Global Fund portfolios into the national HIV and TB programmes, integration of the HIV and TB programmes within the general health system, and system-wide effects of Global Fund support on the health care system in Indonesia. The study relied on a literature review and interviews with 22 key informants using the Systemic Rapid Assessment Toolkit and thematic analysis. Global Fund programmes in Indonesia are highly vertical and centralized, in contrast with the decentralized nature of the Indonesian health system. Consequently, there is more integration of all functions at local levels than centrally. There is a high level of integration of planning of Global Fund HIV and TB portfolios into the National AIDS and TB programmes and some limited integration of these programmes with other disease programmes, through joint working groups. Other synergies include strengthening of stewardship and governance and increased staff recruitment encouraged by incentive payments and training. Monitoring and evaluation functions of the Global Fund programmes are not integrated with the disease programmes, with parallel indicators and reporting systems. System-wide effects include greater awareness of governance and stewardship in response to the temporary suspension of Global Fund funding in 2008, and increased awareness of the need to integrate programme planning, financing and service delivery. Global Fund investment has freed up resources for other programmes, particularly at local levels. However, this may hinder a robust exit strategy from Global Fund funding. Furthermore, Global Fund monetary incentives may result in staff shifting into HIV and TB programmes.

  13. An innovative approach to achieve re-centering and ductility of cement mortar beams through randomly distributed pseudo-elastic shape memory alloy fibers

    NASA Astrophysics Data System (ADS)

    Shajil, N.; Srinivasan, S. M.; Santhanam, M.

    2012-04-01

    Fibers can play a major role in post cracking behavior of concrete members, because of their ability to bridge cracks and distribute the stress across the crack. Addition of steel fibers in mortar and concrete can improve toughness of the structural member and impart significant energy dissipation through slow pull out. However, steel fibers undergo plastic deformation at low strain levels, and cannot regain their shape upon unloading. This is a major disadvantage in strong cyclic loading conditions, such as those caused by earthquakes, where self-centering ability of the fibers is a desired characteristic in addition to ductility of the reinforced cement concrete. Fibers made from an alternative material such as shape memory alloy (SMA) could offer a scope for re-centering, thus improving performance especially after a severe loading has occurred. In this study, the load-deformation characteristics of SMA fiber reinforced cement mortar beams under cyclic loading conditions were investigated to assess the re-centering performance. This study involved experiments on prismatic members, and related analysis for the assessment and prediction of re-centering. The performances of NiTi fiber reinforced mortars are compared with mortars with same volume fraction of steel fibers. Since re-entrant corners and beam columns joints are prone to failure during a strong ground motion, a study was conducted to determine the behavior of these reinforced with NiTi fiber. Comparison is made with the results of steel fiber reinforced cases. NiTi fibers showed significantly improved re-centering and energy dissipation characteristics compared to the steel fibers.

  14. Comparison of two different rehabilitation programmes for thrust plate prosthesis: a randomized controlled study.

    PubMed

    Unver, Bayram; Karatosun, Vasfi; Gunal, Izge; Angin, Salih

    2004-02-01

    Weight bearing after total hip arthroplasty is postponed in order to prevent early loosening, but this negatively affects the rehabilitation programme. For the force transfer characteristics of thrust plate prosthesis (TPP), a new type of hip prosthesis used without cement is similar to the normal hip. We evaluated the possibilities of early weight bearing after TPP by comparing early partial with early full weight bearing. Randomized controlled study. Department of orthopaedics and traumatology in a university hospital. Sixty hips of 51 patients who underwent total hip arthroplasty with TPP were randomly assigned into two groups. Both groups received accelerated rehabilitation programmes: group 1 with early partial weight bearing and group 2 with early full weight bearing. Patients were evaluated by a blind observer preoperatively, at three months after surgery by clinical (measurement of range of hip motion (universal goniometry), muscle strength (Manual Muscle Test), functional test (6-minute walk test), hip function (Harris Hip Scoring System)) and radiographical parameters and one year after surgery by clinical (Harris Hip Scoring System) and radiographical parameters. Group 2 performed transfer activities earlier, had more walking distance at the time of discharge and shorter hospital stay than group 1. At three months, Harris Hip Score, muscle strength, 6-minute walk test, and duration of crutch use were significantly (p < 0.05) in favour of group 2. None of the patients in either group showed signs of loosening one year after the operation. These results suggest that patients with TPP can tolerate an accelerated rehabilitation programme with early weight bearing and will gain the goals of rehabilitation earlier.

  15. "Understanding my ALS". Experiences and reflections of persons with amyotrophic lateral sclerosis and relatives on participation in peer group rehabilitation.

    PubMed

    Madsen, Louise Sofia; Jeppesen, Jørgen; Handberg, Charlotte

    2018-01-26

    The aim of this study was to gain insight into experiences and reflections of persons with amyotrophic lateral sclerosis and relatives concerning the peer group rehabilitation programme "More Life - Less Illness". This qualitative study used the Interpretive Description methodology with Symbolic Interactionism as the analytical framework. Eighteen programme participants representing persons with amyotrophic lateral sclerosis (n = 8) and relatives (n = 10) were included. Data consisted of individual interviews and participant observation. The analysis revealed two categorical themes, "Sense of Community Building" and "Understanding my ALS", which represented the participants' experiences and reflections on peer group rehabilitation. Through the analysis, it became apparent that "Sense of Community Building" gave rise to an increased and personalised understanding of amyotrophic lateral sclerosis among the participants. As a part of the continuous processing of the knowledge gained, "Facing Facts" and "Retaining Normality" appeared as subthemes regarding the participants' ability to live a less dependent and more meaningful life. This study of peer group rehabilitation for persons with amyotrophic lateral sclerosis and relatives indicates that programme participation leads to positive experiences in terms of living a shared meaningful life despite severe disability. The findings may guide practice to develop longitudinal peer group rehabilitation programmes with joint inclusion of persons with amyotrophic lateral sclerosis and relatives. Implications for Rehabilitation Peer group rehabilitation may facilitate an increased and personalised understanding of what it means to live with amyotrophic lateral sclerosis. A programme design with six months of sequential sessions enables a continuous processing of shared experiences and gained knowledge. Joint participation of persons with amyotrophic lateral sclerosis and their relatives supports both their internal relationship and social networking. Peer group rehabilitation in amyotrophic lateral sclerosis should help overcome obstacles concerning the needs of participants, accessibility, and geographical distance.

  16. Reducing bottlenecks: professionals’ and adolescents’ experiences with transitional care delivery

    PubMed Central

    2014-01-01

    Background The purpose of this study was to describe the interventions implemented in a quality improvement programme to improve transitional care and evaluate its effectiveness in reducing bottlenecks as perceived by professionals and improving chronically ill adolescents’ experiences with care delivery. Methods This longitudinal study was undertaken with adolescents and professionals who participated in the Dutch ‘On Your Own Feet Ahead!’ quality improvement programme. This programme followed the Breakthrough Series improvement and implementation strategy. A total of 102/128 (79.7%) professionals from 21 hospital teams filled out a questionnaire at the start of the programme (T0), and 79/123 (64.2%; five respondents had changed jobs) professionals completed the same questionnaire 1 year later (T1). Seventy-two (58.5%) professionals from 21 teams returned questionnaires at both time points. Of 389 and 430 participating adolescents, 36% and 41% returned questionnaires at T0 and T1, respectively. We used descriptive statistics and two-tailed, paired t-tests to investigate improvements in bottlenecks in transitional care (perceived by professionals) and care delivery (perceived by adolescents). Results Professionals observed improvement in all bottlenecks at T1 (vs. T0; p < 0.05), especially in the organisation of care, such as the presence of a joint mission between paediatric and adult care, coordination of care, and availability of more resources for joint care services. Within a 1-year period, the transition programme improved some aspects of patients’ experiences with care delivery, such as the provision of opportunities for adolescents to visit the clinic alone (p < 0.001) and to decide who should be present during consultations (p < 0.05). Conclusions This study demonstrated that transitional care interventions may improve the organisation and coordination of transitional care and better prepare adolescents for the transition to adult care within a 1-year period. By setting specific goals based on experiences with bottlenecks, the breakthrough approach helped to improve transitional care delivery for adolescents with chronic conditions. PMID:24485282

  17. Screw Placement and Osteoplasty Under Computed Tomographic-Fluoroscopic Guidance in a Case of Advanced Metastatic Destruction of the Iliosacral Joint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trumm, Christoph Gregor, E-mail: christoph.trumm@med.lmu.de; Rubenbauer, Bianca; Piltz, Stefan

    We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateralmore » transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.« less

  18. Laboratory simulation of cratering on small bodies

    NASA Technical Reports Server (NTRS)

    Schmidt, Robert M.

    1991-01-01

    A new technique using external pressure was developed to simulate the lithostatic pressure due to self-gravity of small bodies. A 13-in. diameter cylindrical test chamber with L/D of 1 was fabricated to accommodate firing explosive charges with gas overpressures of up to 6000 psi. The chamber was hydrotested to 9000 psi. The method allows much larger scale factors that can be obtained with existing centrifuges and has the correct spherical geometry of self gravity. A simulant for jointed rock to be used in this fixture was developed using weakly cemented basalt. Various strength/pressure scaling theories can now be examined and tested.

  19. An experimental animal model of aseptic loosening of hip prostheses in sheep to study early biochemical changes at the interface membrane

    PubMed Central

    El-Warrak, Alexander O; Olmstead, Marvin; Schneider, Rebecca; Meinel, Lorenz; Bettschart-Wolfisberger, Regula; Akens, Margarete K; Auer, Joerg; von Rechenberg, Brigitte

    2004-01-01

    Background Aseptic loosening of hip prosthesis as it occurs in clinical cases in human patients was attributed to wear particles of the implants, the response of the tissue dominated by macrophages and the production of inflammatory mediators and matrix degrading enzymes; however, the cascade of events initiating the process and their interaction regarding the time course is still open and discussed controversially. Therefore, the goal of this study was to establish an experimental animal model in sheep allowing to follow the cascade of early mechanical and biochemical events within the interface membrane and study the sequence of how they contribute to the pathological bone resorption necessary for aseptic loosening of the implant. Methods A cemented modular system (Biomedtrix) was used as a hip replacement in 24 adult Swiss Alpine sheep, with one group receiving a complete cement mantle as controls (n = 12), and the other group a cement mantle with a standardized, lateral, primary defect in the cement mantle (n = 12). Animals were followed over time for 2 and 8.5 months (n = 6 each). After sacrifice, samples from the interface membranes were harvested from five different regions of the femur and joint capsule. Explant cell cultures were performed and supernatant of cultures were tested and assayed for nitric oxide, prostaglandin E2, caseinolytic and collagenolytic activity. RNA extraction and quantification were performed for inducible nitric oxide synthase, cyclooxygenase-2, interleukin 1, and interleukin 6. Overall differences between groups and time periods and interactions thereof were calculated using a factorial analysis of variance (ANOVA). Results The development of an interface membrane was noticed in both groups at both time points. However, in the controls the interface membrane regressed in thickness and biological activity, while both variables increased in the experimental group with the primary cement mantle defect over time. Nitric oxide (NO) and PGE2 concentrations were higher in the 8.5 months group (P < 0.0001) compared to the 2 months group with a tendency for the unstable group to have higher concentrations. The same was true for collagenolytic activity (P = 0.05), but not for caseinolytic activity that decreased over time (P < 0.0001). Conclusion In this study, a primary cement mantle defect of the femoral shaft elicited biomechanical instability and biochemical changes over time in an experimental animal study in sheep, that resembled the changes described at the bone cement-interface in aseptic loosening of total hip prosthesis in humans. The early biochemical changes may well explain the pathologic bone resorption and formation of an interface membrane as is observed in clinical cases. This animal model may aid in future studies aiming at prevention of aseptic loosening of hip prosthesis and reflect some aspects of the pathogenesis involved. PMID:15113432

  20. Re-thinking global health sector efforts for HIV and tuberculosis epidemic control: promoting integration of programme activities within a strengthened health system.

    PubMed

    Maher, Dermot

    2010-07-05

    The global financial crisis threatens global health, particularly exacerbating diseases of inequality, e.g. HIV/AIDS, and diseases of poverty, e.g. tuberculosis. The aim of this paper is to reconsider established practices and policies for HIV and tuberculosis epidemic control, aiming at delivering better results and value for money. This may be achieved by promoting greater integration of HIV and tuberculosis control programme activities within a strengthened health system. HIV and tuberculosis share many similarities in terms of their disease burden and the recommended stratagems for their control. HIV and tuberculosis programmes implement similar sorts of control activities, e.g. case finding and treatment, which depend for success on generic health system issues, including vital registration, drug procurement and supply, laboratory network, human resources, and financing. However, the current health system approach to HIV and tuberculosis control often involves separate specialised services. Despite some recent progress, collaboration between the programmes remains inadequate, progress in obtaining synergies has been slow, and results remain far below those needed to achieve universal access to key interventions. A fundamental re-think of the current strategic approach involves promoting integrated delivery of HIV and tuberculosis programme activities as part of strengthened general health services: epidemiological surveillance, programme monitoring and evaluation, community awareness of health-seeking behavior, risk behaviour modification, infection control, treatment scale-up (first-line treatment regimens), drug-resistance surveillance, containing and countering drug-resistance (second-line treatment regimens), research and development, global advocacy and global partnership. Health agencies should review policies and progress in HIV and tuberculosis epidemic control, learn mutual lessons for policy development and scaling up interventions, and identify ways of joint planning and joint funding of integrated delivery as part of strengthened health systems. As both a danger and an opportunity, the global financial crisis may entail disaster or recovery for global health sector efforts for HIV and tuberculosis epidemic control. Review of policies and progress in control paves the way for identification of synergies between the two programmes, within strengthened health services. The silver lining in the global economic crisis could be better control of the HIV and tuberculosis epidemics, better overall health system performance and outcomes, and better value for money.

  1. A practical method for estimating maximum shear modulus of cemented sands using unconfined compressive strength

    NASA Astrophysics Data System (ADS)

    Choo, Hyunwook; Nam, Hongyeop; Lee, Woojin

    2017-12-01

    The composition of naturally cemented deposits is very complicated; thus, estimating the maximum shear modulus (Gmax, or shear modulus at very small strains) of cemented sands using the previous empirical formulas is very difficult. The purpose of this experimental investigation is to evaluate the effects of particle size and cement type on the Gmax and unconfined compressive strength (qucs) of cemented sands, with the ultimate goal of estimating Gmax of cemented sands using qucs. Two sands were artificially cemented using Portland cement or gypsum under varying cement contents (2%-9%) and relative densities (30%-80%). Unconfined compression tests and bender element tests were performed, and the results from previous studies of two cemented sands were incorporated in this study. The results of this study demonstrate that the effect of particle size on the qucs and Gmax of four cemented sands is insignificant, and the variation of qucs and Gmax can be captured by the ratio between volume of void and volume of cement. qucs and Gmax of sand cemented with Portland cement are greater than those of sand cemented with gypsum. However, the relationship between qucs and Gmax of the cemented sand is not affected by the void ratio, cement type and cement content, revealing that Gmax of the complex naturally cemented soils with unknown in-situ void ratio, cement type and cement content can be estimated using qucs.

  2. Reusing recycled aggregates in structural concrete

    NASA Astrophysics Data System (ADS)

    Kou, Shicong

    The utilization of recycled aggregates in concrete can minimize environmental impact and reduce the consumption of natural resources in concrete applications. The aim of this thesis is to provide a scientific basis for the possible use of recycled aggregates in structure concrete by conducting a comprehensive programme of laboratory study to gain a better understanding of the mechanical, microstructure and durability properties of concrete produced with recycled aggregates. The study also explored possible techniques to of improve the properties of recycled aggregate concrete that is produced with high percentages (≧ 50%) of recycled aggregates. These techniques included: (a) using lower water-to-cement ratios in the concrete mix design; (b) using fly ash as a cement replacement or as an additional mineral admixture in the concrete mixes, and (c) precasting recycled aggregate concrete with steam curing regimes. The characteristics of the recycled aggregates produced both from laboratory and a commercially operated pilot construction and demolition (C&D) waste recycling plant were first studied. A mix proportioning procedure was then established to produce six series of concrete mixtures using different percentages of recycled coarse aggregates with and without the use of fly ash. The water-to-cement (binder) ratios of 0.55, 0.50, 0.45 and 0.40 were used. The fresh properties (including slump and bleeding) of recycled aggregate concrete (RAC) were then quantified. The effects of fly ash on the fresh and hardened properties of RAC were then studied and compared with those RAC prepared with no fly ash addition. Furthermore, the effects of steam curing on the hardened properties of RAC were investigated. For micro-structural properties, the interfacial transition zones of the aggregates and the mortar/cement paste were analyzed by SEM and EDX-mapping. Moreover, a detailed set of results on the fracture properties for RAC were obtained. Based on the experimental results, a number of recommendations were made on how to optimize the use of recycled aggregates for structural concrete production. The results demonstrate that one of the practical ways to utilize a higher percentage of recycled aggregates in concrete is "precasting" with the use of fly ash and an initial steam curing stage immediately after casting.

  3. Scaling up of HIV-TB collaborative activities: Achievements and challenges in India.

    PubMed

    Deshmukh, Rajesh; Shah, Amar; Sachdeva, K S; Sreenivas, A N; Gupta, R S; Khaparde, S D

    2016-01-01

    India has been implementing HIV/TB collaborative activities since 2001 with rapid scale-up of infrastructure across the country during past decade in National AIDS Control Programme and Revised National TB Control Programme. India has shown over 50% reduction in new infections and around 35% reduction in AIDS-related deaths, thereby being one of the success stories globally. Substantial progress in the implementation of collaborative TB/HIV activities has occurred in India and it is marching towards target set out in the Global Plan to Stop TB and endorsed by the UN General Assembly to halve HIV associated TB deaths by 2015. While the successful approaches have led to impressive gains in HIV/TB control in India, there are emerging challenges including newer pockets with rising HIV trends in North India, increasing drug resistance, high mortality among co-infected patients, low HIV testing rates among TB patients in northern and eastern states in India, treatment delays and drop-outs, stigma and discrimination, etc. In spite of these difficulties, established HIV/TB coordination mechanisms at different levels, rapid scale-up of facilities with decentralisation of treatment services, regular joint supervision and monitoring, newer initiatives like use of rapid diagnostics for early diagnosis of TB among people living with HIV, TB notification, etc. have led to success in combating the threat of HIV/TB in India. This article highlights the steps taken by India, one of the largest HIV/TB programmes in world, in scaling up of the joint HIV-TB collaborative activities, the achievements so far and discusses the emerging challenges which could provide important lessons for other countries in scaling up their programmes. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  4. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

    PubMed

    Schmalzried, T P; Jasty, M; Harris, W H

    1992-07-01

    Thirty-four hips in which there had been prosthetic replacement were selected for study because of the presence of linear (diffuse) or lytic (localized) areas of periprosthetic bone loss. In all hips, there was careful documentation of the anatomical location of the material that had been obtained for histological analysis, and the specific purpose of the removal of the tissue was for examination to determine the cause of the resorption of bone. Specimens from twenty-three hips were retrieved during an operation and from eleven hips, at autopsy. The area of bone loss was linear only in sixteen hips, lytic only in thirteen, and both linear and lytic in five. In all thirty-four hips, intracellular particulate debris was found in the macrophages that were present in the area of bone resorption. All thirty-four had intracellular particles of polyethylene, many of which were less than one micrometer in size. Thirty-one hips had extracellular particles of polyethylene as well. Twenty-two of the thirty-four hips had intracellular metallic debris; in ten, metallic debris was found extracellularly as well. Ten of the sixteen cemented specimens had intracellular and extracellular polymethylmethacrylate debris. In the mechanically stable prostheses--cemented and uncemented--polyethylene wear debris was identified in areas of bone resorption far from the articular surfaces. The number of macrophages in a microscopic field was directly related to the amount of particulate polyethylene debris that was visible by light microscopy. Although the gross radiographic appearances of linear bone loss and lytic bone loss were different, the histological appearance of the regions in which there was active bone resorption was similar. Regardless of the radiographic appearance and anatomical origin of the specimen, bone resorption was found to occur in association with macrophages that were laden with polyethylene debris. In general, the number of macrophages present had a direct relationship to the degree of bone resorption that was seen. We believe that these findings indicate that joint fluid penetrates far more extensively than previously thought, even in a well fixed component, along the interface between the prosthesis and bone and in the periprosthetic tissues; it is often more extensive than is shown by arthrography. We therefore suggest the concept of the effective joint space to include all periprosthetic regions that are accessible to joint fluid and thus accessible to particulate debris.(ABSTRACT TRUNCATED AT 400 WORDS)

  5. A modified PMMA cement (Sub-cement) for accelerated fatigue testing of cemented implant constructs using cadaveric bone.

    PubMed

    Race, Amos; Miller, Mark A; Mann, Kenneth A

    2008-10-20

    Pre-clinical screening of cemented implant systems could be improved by modeling the longer-term response of the implant/cement/bone construct to cyclic loading. We formulated bone cement with degraded fatigue fracture properties (Sub-cement) such that long-term fatigue could be simulated in short-term cadaver tests. Sub-cement was made by adding a chain-transfer agent to standard polymethylmethacrylate (PMMA) cement. This reduced the molecular weight of the inter-bead matrix without changing reaction-rate or handling characteristics. Static mechanical properties were approximately equivalent to normal cement. Over a physiologically reasonable range of stress-intensity factor, fatigue crack propagation rates for Sub-cement were higher by a factor of 25+/-19. When tested in a simplified 2 1/2-D physical model of a stem-cement-bone system, crack growth from the stem was accelerated by a factor of 100. Sub-cement accelerated both crack initiation and growth rate. Sub-cement is now being evaluated in full stem/cement/femur models.

  6. Building a School Leadership Programme: An American Paradox of Autonomy and Accountability

    ERIC Educational Resources Information Center

    Reyes-Guerra, Daniel; Russo, Marianne R.; Bogotch, Ira E.; Vásquez-Colina, Maria D.

    2014-01-01

    School districts within the USA face ever-decreasing autonomy in rendering decisions regarding instruction, curriculum and the leading and managing of schools at the local level due to the ever-increasing accountability measures implemented by district, state and federal governments. This study investigates a joint university-school district…

  7. In Conversation with Paul Burstow

    ERIC Educational Resources Information Center

    Holman, Andrew

    2013-01-01

    Paul Burstow, a former minister for social care, was once charged with finding savings in care services. He completed his last two years, cut the Valuing People Now programme early, and returned to the back benches. He did, however, draft a Care and Support Bill and has subsequently used this experience to chair a joint Parliamentary Scrutiny…

  8. "Digital Futures in Teacher Education": Exploring Open Approaches towards Digital Literacy

    ERIC Educational Resources Information Center

    Gruszczynska, Anna; Merchant, Guy; Pountney, Richard,

    2013-01-01

    This paper reports the findings of a project "Digital Futures in Teacher Education" (DeFT) undertaken as part of the third phase of the Joint Information Systems Committee (JISC) UK Open Educational Resources (OER) programme. It builds on previous work (Gruszczynska and Pountney, 2012, 2013) that has addressed attempts to embed OER…

  9. The UK-Japan Young Scientist Workshop Programme...

    ERIC Educational Resources Information Center

    Albone, Eric; Okano, Toru

    2012-01-01

    The authors have been running UK-Japan Young Scientist Workshops at universities in Britain and Japan since 2001: for the past three years in England with Cambridge University and, last year, also with Kyoto University and Kyoto University of Education. For many years they have worked jointly with colleagues in a group of Super Science High…

  10. Service-Oriented Architecture and Curriculum Transformation at Manchester Metropolitan University

    ERIC Educational Resources Information Center

    Stubbs, Mark; Range, Phil

    2011-01-01

    Purpose: The need to establish more flexible and adaptable university curricula has been recognised as a strategic priority in recent years and has been supported by a number of initiatives including the Curriculum Design and Delivery programme funded by the Joint Information System Committee (JISC) in the UK. The challenges of addressing…

  11. Effective Partnership Working in Music Education: Principles and Practice

    ERIC Educational Resources Information Center

    Hallam, Richard

    2011-01-01

    Successful partnerships between policy makers and deliverers, providers and recipients can be both strategic and operational. Partnerships can operate in several different ways at the same time. Joint programmes achieve more than each organization or individual can achieve separately. The impact on children and young people can be profound if the…

  12. Storytelling and the Web in South African Museums.

    ERIC Educational Resources Information Center

    Goodnow, Katherine J.; Natland, Yngvar

    The Iziko museums in Cape Town, South Africa in collaboration with the International Museums Studies Programme at the University of Bergen, Norway, have jointly developed a Web-based concept that combines oral storytelling with new technology to connect schools in the South and North. Awaiting funding at the time of publication, this project was…

  13. Embedding Community Engagement in South African Higher Education

    ERIC Educational Resources Information Center

    Lazarus, Josef; Erasmus, Mabel; Hendricks, Denver; Nduna, Joyce; Slamat, Jerome

    2008-01-01

    Community engagement was a relatively unknown concept in South African higher education until the late 1990s. In response to the call of the White Paper on the Transformation of Higher Education (1997) for "feasibility studies and pilot programmes which explore the potential of community service in higher education" the Joint Education…

  14. Promoting Environmental Citizenship and Corporate Social Responsibility through a School/Industry/University Partnership

    ERIC Educational Resources Information Center

    Gebbels, Susan; Evans, Stewart M.; Delany, Jane E.

    2011-01-01

    A partnership was formed between King Edward VI School Morpeth (UK) and the pharmaceutical company Merck, Sharp and Dohme within the programme of "Joint Responsibility" operated by the Dove Marine Laboratory (Newcastle University, UK). Pupils surveyed an ecologically important coastal area in northeast England and made 15 recommendations…

  15. The effect of calf muscle stretching exercises on ankle joint dorsiflexion and dynamic foot pressures, force and related temporal parameters.

    PubMed

    Macklin, K; Healy, A; Chockalingam, N

    2012-03-01

    Previous research has found that ankle joint equinus can lead to foot pathologies. Calf stretching exercises are a common treatment prescription; however, no dynamic quantitative data on its effectiveness is available. To investigate the effect of calf muscle stretching on ankle joint dorsiflexion and subsequent changes within dynamic forefoot peak plantar pressures (PPP), force and temporal parameters. Thirteen runners with ankle joint equinus were required to perform calf muscle stretching twice a day (morning and evening) on a Flexeramp. Measurements were collected on day 1, week 4 and week 8. A repeated measures ANOVA with Bonferroni-adjusted post hoc comparisons was used to assess differences across the three data collection sessions. Findings indicated that the calf stretching program increased ankle joint dorsiflexion significantly (from 5° to 16°, p≤0.05). The adaptive kinetics brought about by the increased ankle joint range of motion included significantly increased forefoot PPP and maximum force during stance phase but decreased time between heel contact and heel lift and total stance phase time. The calf stretching programme used in this study was found to increase ankle joint dorsiflexion and hence can be used for first line conservative management of ankle equinus. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Mineral resource of the month: hydraulic cement

    USGS Publications Warehouse

    van Oss, Hendrik G.

    2012-01-01

    Hydraulic cements are the binders in concrete and most mortars and stuccos. Concrete, particularly the reinforced variety, is the most versatile of all construction materials, and most of the hydraulic cement produced worldwide is portland cement or similar cements that have portland cement as a basis, such as blended cements and masonry cements. Cement typically makes up less than 15 percent of the concrete mix; most of the rest is aggregates. Not counting the weight of reinforcing media, 1 ton of cement will typically yield about 8 tons of concrete.

  17. Circulating and synovial antibody profiling of juvenile arthritis patients by nucleic acid programmable protein arrays

    PubMed Central

    2012-01-01

    Introduction Juvenile idiopathic arthritis (JIA) is a heterogeneous disease characterized by chronic joint inflammation of unknown cause in children. JIA is an autoimmune disease and small numbers of autoantibodies have been reported in JIA patients. The identification of antibody markers could improve the existing clinical management of patients. Methods A pilot study was performed on the application of a high-throughput platform, the nucleic acid programmable protein array (NAPPA), to assess the levels of antibodies present in the systemic circulation and synovial joint of a small cohort of juvenile arthritis patients. Plasma and synovial fluid from 10 JIA patients was screened for antibodies against 768 proteins on NAPPAs. Results Quantitative reproducibility of NAPPAs was demonstrated with > 0.95 intra-array and inter-array correlations. A strong correlation was also observed for the levels of antibodies between plasma and synovial fluid across the study cohort (r = 0.96). Differences in the levels of 18 antibodies were revealed between sample types across all patients. Patients were segregated into two clinical subtypes with distinct antibody signatures by unsupervised hierarchical cluster analysis. Conclusion The NAPPAs provide a high-throughput quantitatively reproducible platform to screen for disease-specific autoantibodies at the proteome level on a microscope slide. The strong correlation between the circulating antibody levels and those of the inflamed joint represents a novel finding and provides confidence to use plasma for discovery of autoantibodies in JIA, thus circumventing the challenges associated with joint aspiration. We expect that autoantibody profiling of JIA patients on NAPPAs could yield antibody markers that can act as criteria to stratify patients, predict outcomes and understand disease etiology at the molecular level. PMID:22510425

  18. Periprosthetic Joint Infection of Shoulder Arthroplasties: Diagnostic and Treatment Options

    PubMed Central

    Sevelda, Florian

    2017-01-01

    Periprosthetic joint infection (PJI) is one of the most frequent reasons for painful shoulder arthroplasties and revision surgery of shoulder arthroplasties. Cutibacterium acnes (Propionibacterium acnes) is one of the microorganisms that most often causes the infection. However, this slow growing microorganism is difficult to detect. This paper presents an overview of different diagnostic test to detect a periprosthetic shoulder infection. This includes nonspecific diagnostic tests and specific tests (with identifying the responsible microorganism). The aspiration can combine different specific and nonspecific tests. In dry aspiration and suspected joint infection, we recommend a biopsy. Several therapeutic options exist for the treatment of PJI of shoulder arthroplasties. In acute infections, the options include leaving the implant in place with open debridement, septic irrigation with antibacterial fluids like octenidine or polyhexanide solution, and exchange of all removable components. In late infections (more than four weeks after implantation) the therapeutic options are a permanent spacer, single-stage revision, and two-stage revision with a temporary spacer. The functional results are best after single-stage revisions with a success rate similar to two-stage revisions. For single-stage revisions, the microorganism should be known preoperatively so that specific antibiotics can be mixed into the cement for implantation of the new prosthesis and specific systemic antibiotic therapy can be applied to support the surgery. PMID:29423407

  19. Fatigue Properties of Butt Welded Aluminum Alloy and Carbon Steel Joints by Friction Stirring

    NASA Astrophysics Data System (ADS)

    Okane, M.; Shitaka, T.; Ishida, M.; Chaki, T.; Yasui, T.; Fukumoto, M.

    2017-05-01

    The butt dissimilar joints of Al-Mg-Si alloy JIS A6063 and carbon steel JIS S45C by means of friction stir welding were prepared for investigating fatigue properties of the joints. The joining tool used has cemented carbide thread probe and a shoulder made of alloy tool steel. All the fatigue tests were carried out under a load-controlled condition with a load ratio R=0.1 in air at room temperature. From the experimental results, it was found that hardness near the interface in A6063 was lower than that of base material. Three types of fatigue fracture occurred even in case of same welding condition. The first one was fracture at boundary between the lower hardness region and base material in A6063, the second type was initiated in the stir zone by FSW process and the last one was fracture at interface. Fatigue strength in case of the second one was lower than others. Furthermore, to investigate the effect of heat treatment on fatigue properties of the dissimilar joints, fatigue tests were also carried out with using the specimens which were heat treated under the same condition to aging process in T6 treatment. Fatigue fracture was initiated at interface between A6063 and S45C in case of the heat treated specimen, but fatigue strength was improved approximately 25% as compared with that of the non-heat treated specimen.

  20. Evaluation of the amount of excess cement around the margins of cement-retained dental implant restorations: the effect of the cement application method.

    PubMed

    Chee, Winston W L; Duncan, Jesse; Afshar, Manijeh; Moshaverinia, Alireza

    2013-04-01

    Complete removal of excess cement from subgingival margins after cementation of implant-supported restorations has been shown to be unpredictable. Remaining cement has been shown to be associated with periimplant inflammation and bleeding. The purpose of this study was to investigate and compare the amount of excess cement after cementation with 4 different methods of cement application for cement-retained implant-supported restorations. Ten implant replicas/abutments (3i) were embedded in acrylic resin blocks. Forty complete veneer crowns (CVCs) were fabricated by waxing onto the corresponding plastic waxing sleeves. The wax patterns were cast and the crowns were cemented to the implant replicas with either an interim (Temp Bond) or a definitive luting agent (FujiCEM). Four methods of cement application were used for cementation: Group IM-Cement applied on the internal marginal area of the crown only; Group AH-Cement applied on the apical half of the axial walls of the crown; Group AA-Cement applied to all axial walls of the interior surface of the crown, excluding the occlusal surface; and Group PI-Crown filled with cement then seated on a putty index formed to the internal configuration of the restoration (cementation device) (n=10). Cement on the external surfaces was removed before seating the restoration. Cement layers were applied on each crown, after which the crown was seated under constant load (80 N) for 10 minutes. The excess cement from each specimen was collected and measured. One operator performed all the procedures. Results for the groups were compared, with 1 and 2-way ANOVA and the Tukey multiple range test (α=.05). No significant difference in the amount of excess/used cement was observed between the 2 different types of cements (P=.1). Group PI showed the least amount of excess cement in comparison to other test groups (P=.031). No significant difference was found in the amount of excess cement among groups MI, AH, and AA. Group AA showed the highest amount of excess cement. The volume of cement used for group PI specimens was significantly higher than for those in the other groups (P=.001). With respect to the volume of cement loaded into the test crowns no statistically significant difference was observed among other test groups (groups IM, AH, and AA). Group MI used the least amount of cement, followed by group AH and AA. No correlation between the amount of used cement and the amount of excess cement was found in any of the tested groups. Within the limitations of this in vitro study, the least amount of excess cement was present when a cementation device was used to displace the excess cement before seating the crown on the abutment (Group PI). With this technique a uniform layer of the luting agent is distributed over the internal surface of the crown leaving minimal excess cement when the restoration is seated. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Effects of a cementing technique in addition to luting agent on the uniaxial retention force of a single-tooth implant-supported restoration: an in vitro study.

    PubMed

    Santosa, Robert E; Martin, William; Morton, Dean

    2010-01-01

    Excess residual cement around the implant margin has been shown to be detrimental to the peri-implant tissue. This in vitro study examines the retentive strengths of two different cementing techniques and two different luting agents on a machined titanium abutment and solid screw implants. The amount of reduction of excess cement weight between the two cementation techniques was assessed. Forty gold castings were fabricated for 4.1 mm in diameter and 10 mm in length solid-screw dental implants paired with 5.5-mm machined titanium abutments. Twenty implants received a provisional cement, and 20 implants received a definitive cement. Each group was further divided into two groups. In the control group, cement was applied and the castings seated over the implant-abutment assembly. The excess cement was then removed. In the study group, a "practice abutment" was used to express excess cement prior to cementation. The weight of the implant-casting assembly was measured and the residual weight of cement was calculated. The samples were then stored for 24 hours at 100% humidity prior to tensile strength testing. Statistical analysis revealed significant differences in tensile strength across the groups. Further Tukey tests showed no significant difference in tensile strength between the practice abutment technique and the conventional technique for both definitive and provisional cements. There was a significant reduction in residual cement weight, irrespective of the type of cement, when the practice abutment was used prior to cementation. Cementation of implant restorations on a machined abutment using the practice abutment technique and definitive cement may provide similar uniaxial retention force and significantly reduced residual cement weight compared to the conventional technique of cement removal.

  2. Influence of cement film thickness on the retention of implant-retained crowns.

    PubMed

    Mehl, Christian; Harder, Sönke; Steiner, Martin; Vollrath, Oliver; Kern, Matthias

    2013-12-01

    The main goal of this study was to establish a new, high precision procedure to evaluate the influence of cement film thickness on the retention of cemented implant-retained crowns. Ninety-six tapered titanium abutments (6° taper, 4.3 mm diameter, Camlog) were shortened to 4 mm. Computer-aided design was used to design the crowns, and selective laser sintering, using a cobalt-chromium alloy, was used to produce the crowns. This method used a focused high-energy laser beam to fuse a localized region of metal powder to build up the crowns gradually. Before cementing, preset cement film thicknesses of 15, 50, 80, or 110 μm were established. Glass ionomer, polycarboxylate, or resin cements were used for cementation. After 3 days storage in demineralized water, the retention of the crowns was measured in tension using a universal testing machine. The cement film thicknesses could be achieved with a high level of precision. Interactions between the factors cement and cement film thickness could be found (p ≤ 0.001). For all cements, crown retention decreased significantly between a cement film thickness of 15 and 50 μm (p ≤ 0.001). At 15 μm cement film thickness, the resin cement was the most retentive cement, followed by the polycarboxylate and then the glass ionomer cement (p ≤ 0.05). The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns. © 2013 by the American College of Prosthodontists.

  3. The mechanical effect of the existing cement mantle on the in-cement femoral revision.

    PubMed

    Keeling, Parnell; Lennon, Alexander B; Kenny, Patrick J; O'Reilly, Peter; Prendergast, Patrick J

    2012-08-01

    Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct. Primary cement mantles were formed by cementing a polished stem into sections of tubular steel. If in the test group, the mantle underwent conditioning in saline to simulate ageing and was subject to a fatigue of 1 million cycles. If in the control group no such conditioning or fatigue was carried out. The cement-in-cement procedure was then undertaken. Both groups underwent a fatigue of 1 million cycles subsequent to the revision procedure. Application of a Mann-Whitney test on the recorded subsidence (means: 0.51, 0.46, n=10+10, P=0.496) and inducible displacement (means: 0.38, 0.36, P=0.96) revealed that there was no statistical difference between the groups. This study represents further biomechanical investigation of the mechanical behaviour of cement-in-cement revision constructs. Results suggest that pre-revision fatigue and ageing of the cement may not be deleterious to the mechanical performance of the revision construct. Thus, this study provides biomechanical evidence to back-up recent successes with this useful revision technique. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. The effect of using a cement gun with a narrow nozzle on cement penetration for total elbow arthroplasty: a cadaveric study.

    PubMed

    Smith, Geoffrey C S; McCann, Phillip S; Simpson, Danielle; Blewitt, Neil; Amirfeyz, Rouin

    2015-02-01

    To compare the cement mantle characteristics associated with use of a narrow nozzle cement gun versus the use of a 60-mL catheter tip syringe. Twelve cadaveric distal humeri were cemented with either a cement gun or a syringe without canal occlusion. The humeri were sectioned and photographed. The corticocancellous junction and the outer margin of the cement mantle were analyzed digitally. The corticocancellous junction defined the available area for cement penetration. The outline of the cement mantle defined the actual area of penetration. The ratio of penetration to the available area was recorded for each slice. The mean ratio for each humerus was multiplied by the number of slices in that sample containing cement to calculate a cement index. The cement penetration ratios observed in cross-sections at the same level and the cement index were significantly greater with the use of the cement gun than with the use of the syringe. There was no difference in the number of slices that contained cement. The use of a cement gun with a narrow nozzle improved cement mantle characteristics compared with the use of a syringe when measured in a cadaveric model in the absence of canal occlusion. Improving cement mantle characteristics may decrease the incidence of aseptic loosening after total elbow arythroplasty. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Interleukin-6 as an early marker for fat embolism

    PubMed Central

    Yoga, R; Theis, JC; Walton, M; Sutherland, W

    2009-01-01

    Background Fat Embolism is a complication of long bone fractures, intramedullary fixation and joint arthroplasty. It may progress to fat embolism syndrome, which is rare but involves significant morbidity and can occasionally be fatal. Fat Embolism can be detected at the time of embolization by transoesophageal echocardiography or atrial blood sampling. Later, a combination of clinical signs and symptoms will point towards fat embolism but there is no specific test to confirm the diagnosis. We investigated serum Interleukin-6 (IL-6) as a possible early marker for fat embolism. Methods An animal study was conducted to simulate a hip replacement in 31 adult male Sprague Dawley rats. The procedure was performed under general anesthesia and the animals divided into 3 groups: control, uncemented and cemented. Following surgery and recovery from anaesthesia, the rats allowed to freely mobilize in their cages. Blood was taken before surgery and at 6 hours, 12 hours and 24 hours to measure serum IL-6 levels. The rats were euthanized at 24 hours and lungs removed and stained for fat. The amount of fat seen was then correlated with serum IL-6 levels. Results No rats in the control group had fat emboli. Numerous fat emboli were seen in both the uncemented and cemented implant groups. The interleukin levels were raised in all groups reaching a peak at 12 hours after surgery reaching 100 pg/ml in the control group and around 250 pg/ml in the uncemented and cemented implant groups. The IL-6 levels in the control group were significantly lower than any of the implant groups at 12 and 24 hours. At these time points, the serum IL-6 correlated with the amount of fat seen on lung histology. Conclusion Serum IL-6 is a possible early marker of fat embolism. PMID:19523233

  6. Effect of temporary cements on the shear bond strength of luting cements

    PubMed Central

    FIORI-JÚNIOR, Marco; MATSUMOTO, Wilson; SILVA, Raquel Assed Bezerra; PORTO-NETO, Sizenando Toledo; SILVA, Jaciara Miranda Gomes

    2010-01-01

    Objective The purpose of this study was to evaluate, by shear bond strength (SBS) testing, the influence of different types of temporary cements on the final cementation using conventional and self-etching resin-based luting cements. Material and Methods Forty human teeth divided in two halves were assigned to 8 groups (n=10): I and V (no temporary cementation); II and VI: Ca(OH)2-based cement; III and VII: zinc oxide (ZO)based cement; IV and VIII: ZO-eugenol (ZOE)-based cement. Final cementation was done with RelyX ARC cement (groups I to IV) and RelyX Unicem cement (groups V to VIII). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Results Means were (MPa): I - 3.80 (±1.481); II - 5.24 (±2.297); III - 6.98 (±1.885); IV - 6.54 (±1.459); V - 5.22 (±2.465); VI - 4.48 (±1.705); VII - 6.29 (±2.280); VIII - 2.47 (±2.076). Comparison of the groups that had the same temporary cementation (Groups II and VI; III and VII; IV and VIII) showed statistically significant difference (p<0.001) only between Groups IV and VIII, in which ZOE-based cements were used. The use of either Ca(OH)2 based (Groups II and VI) or ZO-based (Groups III and VII) cements showed no statistically significant difference (p>0.05) for the different luting cements (RelyXTM ARC and RelyXTM Unicem). The groups that had no temporary cementation (Groups I and V) did not differ significantly from each other either (p>0.05). Conclusion When temporary cementation was done with ZO- or ZOE-based cements and final cementation was done with RelyX ARC, there was an increase in the SBS compared to the control. In the groups cemented with RelyX Unicem, however, the use of a ZOE-based temporary cement affected negatively the SBS of the luting agent used for final cementation. PMID:20379679

  7. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  8. Corporate ergonomics programme at Ford Motor Company.

    PubMed

    Joseph, Bradley S

    2003-01-01

    The use of ergonomic principles in automobile assembly and manufacturing operations has become an important part of a comprehensive health and safety process as well as an integral part of the engineering systems. Ford Motor Company has developed an ergonomics process to manage issues related to injury and illness (e.g., musculoskeletal diseases) and to ensure the appropriate use of human resources on the plant floor. The ergonomics programme uses joint labour and management teams to identify and evaluate jobs and develop and implement solutions. This paper summarises the efforts of the Ford Motor Company in implementing and maintaining the programme. Key strategies are outlined that provide important links to internal organisational units that are critical to fully utilise the ergonomics process. In addition, the paper outlines differences between proactive and reactive efforts and shows the importance of using the information generated by the initiatives for process improvement.

  9. Meteoric calcite cementation: diagenetic response to relative fall in sea-level and effect on porosity and permeability, Las Negras area, southeastern Spain

    NASA Astrophysics Data System (ADS)

    Li, Zhaoqi; Goldstein, Robert H.; Franseen, Evan K.

    2017-03-01

    A dolomitized Upper Miocene carbonate system in southeast Spain contains extensive upper and lower zones of calcite cementation that cut across the stratigraphy. Cement textures including isopachous and circumgranular, which are consistent with phreatic-zone cementation. Cements in the upper cemented zone are non-luminescent, whereas those in the lower cemented zone exhibit multiple bands of luminescent and non-luminescent cements. In the upper cemented zone, isotopic data show two meteoric calcite lines (MCL) with mean δ18O at - 5.1‰ and - 5.8‰ VPDB, whereas no clear MCL is defined in the lower cemented zone where mean δ18O for calcite cement is at - 6.7‰ VPDB. δ13C values in both cement zones are predominantly negative, ranging from - 10 to + 2‰ VPDB, suggestive of carbon from soil gas or decayed organics. Measurements of Tm ice in primary fluid inclusions yield a mode of 0.0 °C in both zones, indicating calcite cementation from fresh water. These two zones define the positions of two different paleo-water tables that formed during a relative sea-level fall and erosional downcutting during the Plio-Pleistocene. The upper cemented zone pre-dated the lower cemented zone on the basis of known relative sea-level history. Meteoric calcite cementation reduced porosity and permeability, but measured values are inconsistent with simple filling of open pore space. Each texture, boundstone, grainstone, packstone, wackestone, produces a different relationship between percent calcite cement and porosity/permeability. Distribution of cements may be predictable on the basis of known sea-level history, and the effect of the cementation can be incorporated into subsurface geomodels by defining surfaces of rock boundaries that separate cemented zones from uncemented zones, and applying texture-specific relationships among cementation, porosity and permeability.

  10. Traction test of temporary dental cements.

    PubMed

    Román-Rodríguez, Juan-Luis; Millan-Martínez, Diego; Fons-Font, Antonio; Agustín-Panadero, Rubén; Fernández-Estevan, Lucía

    2017-04-01

    Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear (TBC) and Telio CS link (TE). Each sample underwent traction testing, both with thermocycling (190 cycles at 5-55º) and without thermocycling. TE and TBC obtained the highest traction resistance values. Thermocycling reduced the resistance of all cements except TBC. The dual-cure esthetic cements tested provided optimum outcomes for bonding provisional restorations. Key words: Temporary dental cements, cements resistance.

  11. High Early-Age Strength Concrete for Rapid Repair

    NASA Astrophysics Data System (ADS)

    Maler, Matthew O.

    The aim of this research was to identify High Early-Age Strength (HES) concrete batch designs, and evaluate their suitability for use in the rapid repair of highways and bridge decks. To this end, two criteria needed to be met; a minimum compressive strength of 20.68 MPa (3000 psi) in no later than 12 hours, and a drying shrinkage of less than 0.06 % at 28 days after curing. The evaluations included both air-entrained, and non-air-entrained concretes. The cement types chosen for this study included Type III and Type V Portland cement and "Rapid Set"--a Calcium Sulfoaluminate (CSA) cement. In addition, two blended concretes containing different ratios of Type V Portland cement and CSA cement were investigated. The evaluation of the studied concretes included mechanical properties and transport properties. Additionally, dimensional stability and durability were investigated. Evaluations were conducted based on cement type and common cement factor. Fresh property tests showed that in order to provide a comparable workability, and still remain within manufactures guideline for plasticizer, the water-to-cement ratio was adjusted for each type of cement utilized. This resulted in the need to increase the water-to-cement ratio as the Blaine Fineness of the cement type increased (0.275 for Type V Portland cement, 0.35 for Type III Portland cement, and 0.4 for Rapid Set cement). It was also observed that negligible changes in setting time occurred with increasing cement content, whereas changes in cement type produced notable differences. The addition of air-entrainment had beneficial effect on workability for the lower cement factors. Increasing trends for peak hydration heat were seen with increases in cement factor, cement Blaine Fineness, and accelerator dosage. Evaluation of hardened properties revealed opening times as low as 5 hours for Type V Portland cement with 2.0 % accelerator per cement weight and further reduction in opening time by an hour when accelerator dosage was increased to 2.8 % by cement weight. When Type III Portland cement and Rapid Set cement were used, the opening time reduced to as low as 4.5 hours and 1 hour, respectively. The results for Type V Portland cement concretes showed that as cement factor increased so did mechanical properties until the cement factor exceeded 504 kg/m3 (850 lb/yd3), at which point the peak heat of hydration exceeded 46.1 °C (115 °F) and the mechanical properties decreased. Other evaluations on the studied High Early-Age Strength Type V Portland cement concretes revealed increases in absorption, rapid chloride penetration, water permeability, drying shrinkage, corrosion resistance, and resistance to wear with increases in cement content. The addition of air-entrainment had adverse effects on compressive strength, absorption, and rapid chloride migration; while showing lower values for rapid chloride penetration. Curing had positive effects on all hardened properties of the studied HES concretes containing Type V cement. When examining the studied Type III Portland cement concretes, it was seen that an increase in cement content led to decreases in mechanical properties. It is noted that the peak heat of hydration for these concrete exceeded the threshold of 46.1 °C (115 °F). In addition, increases in cement factor also resulted in decreases in rapid chloride migration, frost resistance and resistance to wear. Increases in cement content resulted in increases in absorption, rapid chloride penetration, water permeability, drying shrinkage, and corrosion resistance. The use of air-entrainment imparted decreases in compressive strength and rapid chloride penetration, increases in absorption, and negligible effects on rapid chloride migration. Extending curing period resulted in beneficial effects on all properties of the studied Type III cement concretes. The studied CSA cement concretes had slightly decreasing strength trends as cement content was increased. Concretes containing CSA cement produced the lowest opening time (one hour) and the highest peak hydration heats of all concretes studied. While its corrosion and frost resistance reduced as cement content increased, the absorption and rapid chloride penetration increased with increasing cement content. For drying shrinkage, opening time curing showed more volume change with increasing cement content, whereas extending curing to 24 hours and 28 days resulted in reduction of drying shrinkage. Increasing cement factor had minimal effects on water permeability and abrasion resistance. Air-entrainments reduced compressive strength, but increased absorption and rapid chloride penetration. Rapid chloride migration was found to be incompatible with CSA cements concretes. All hardened properties of the studied CSA cement concretes improved once curing age was extended to 24 hours and 28 days. (Abstract shortened by ProQuest.).

  12. A compact roller-gear pitch-yaw joint module: Design and control issues

    NASA Technical Reports Server (NTRS)

    Dohring, Mark E.; Anderson, William J.; Newman, Wyatt S.; Rohn, Douglas A.

    1993-01-01

    Robotic systems have been proposed as a means of accomplishing assembly and maintenance tasks in space. The desirable characteristics of these systems include compact size, low mass, high load capacity, and programmable compliance to improve assembly performance. In addition, the mechanical system must transmit power in such a way as to allow high performance control of the system. Efficiency, linearity, low backlash, low torque ripple, and low friction are all desirable characteristics. This work presents a pitch-yaw joint module designed and built to address these issues. Its effectiveness as a two degree-of-freedom manipulator using natural admittance control, a method of force control, is demonstrated.

  13. Synthesis of Portland cement and calcium sulfoaluminate-belite cement for sustainable development and performance

    NASA Astrophysics Data System (ADS)

    Chen, Irvin Allen

    Portland cement concrete, the most widely used manufactured material in the world, is made primarily from water, mineral aggregates, and portland cement. The production of portland cement is energy intensive, accounting for 2% of primary energy consumption and 5% of industrial energy consumption globally. Moreover, portland cement manufacturing contributes significantly to greenhouse gases and accounts for 5% of the global CO2 emissions resulting from human activity. The primary objective of this research was to explore methods of reducing the environmental impact of cement production while maintaining or improving current performance standards. Two approaches were taken, (1) incorporation of waste materials in portland cement synthesis, and (2) optimization of an alternative environmental friendly binder, calcium sulfoaluminate-belite cement. These approaches can lead to less energy consumption, less emission of CO2, and more reuse of industrial waste materials for cement manufacturing. In the portland cement part of the research, portland cement clinkers conforming to the compositional specifications in ASTM C 150 for Type I cement were successfully synthesized from reagent-grade chemicals with 0% to 40% fly ash and 0% to 60% slag incorporation (with 10% intervals), 72.5% limestone with 27.5% fly ash, and 65% limestone with 35% slag. The synthesized portland cements had similar early-age hydration behavior to commercial portland cement. However, waste materials significantly affected cement phase formation. The C3S--C2S ratio decreased with increasing amounts of waste materials incorporated. These differences could have implications on proportioning of raw materials for cement production when using waste materials. In the calcium sulfoaluminate-belite cement part of the research, three calcium sulfoaluminate-belite cement clinkers with a range of phase compositions were successfully synthesized from reagent-grade chemicals. The synthesized calcium sulfoaluminate-belite cement that contained medium C4A3 S¯ and C2S contents showed good dimensional stability, sulfate resistance, and compressive strength development and was considered the optimum phase composition for calcium sulfoaluminate-belite cement in terms of comparable performance characteristics to portland cement. Furthermore, two calcium sulfoaluminate-belite cement clinkers were successfully synthesized from natural and waste materials such as limestone, bauxite, flue gas desulfurization sludge, Class C fly ash, and fluidized bed ash proportioned to the optimum calcium sulfoaluminate-belite cement synthesized from reagent-grade chemicals. Waste materials composed 30% and 41% of the raw ingredients. The two calcium sulfoaluminate-belite cements synthesized from natural and waste materials showed good dimensional stability, sulfate resistance, and compressive strength development, comparable to commercial portland cement.

  14. Comparative study on strength properties of cement mortar by partial replacement of cement with ceramic powder and silica fume

    NASA Astrophysics Data System (ADS)

    Himabindu, Ch.; Geethasri, Ch.; Hari, N.

    2018-05-01

    Cement mortar is a mixture of cement and sand. Usage of high amount of cement increases the consumption of natural resources and electric power. To overcome this problem we need to replace cement with some other material. Cement is replaced with many other materials like ceramic powder, silica fume, fly ash, granulated blast furnace slag, metakaolin etc.. In this research cement is replaced with ceramic powder and silica fume. Different combinations of ceramic powder and silica fume in cement were replaced. Cement mortar cubes of 1:3 grade were prepared. These cubes were cured under normal water for 7 days, 14days and 28 days. Compressive strength test was conducted for all mixes of cement mortar cubes.

  15. Effect of dental cements on peri-implant microbial community: comparison of the microbial communities inhabiting the peri-implant tissue when using different luting cements.

    PubMed

    Korsch, Michael; Marten, Silke-Mareike; Dötsch, Andreas; Jáuregui, Ruy; Pieper, Dietmar H; Obst, Ursula

    2016-12-01

    Cementing dental restorations on implants poses the risk of undetected excess cement. Such cement remnants may favor the development of inflammation in the peri-implant tissue. The effect of excess cement on the bacterial community is not yet known. The aim of this study was to analyze the effect of two different dental cements on the composition of the microbial peri-implant community. In a cohort of 38 patients, samples of the peri-implant tissue were taken with paper points from one implant per patient. In 15 patients, the suprastructure had been cemented with a zinc oxide-eugenol cement (Temp Bond, TB) and in 23 patients with a methacrylate cement (Premier Implant Cement, PIC). The excess cement found as well as suppuration was documented. Subgingival samples of all patients were analyzed for taxonomic composition by means of 16S amplicon sequencing. None of the TB-cemented implants had excess cement or suppuration. In 14 (61%) of the PIC, excess cement was found. Suppuration was detected in 33% of the PIC implants without excess cement and in 100% of the PIC implants with excess cement. The taxonomic analysis of the microbial samples revealed an accumulation of oral pathogens in the PIC patients independent of the presence of excess cement. Significantly fewer oral pathogens occurred in patients with TB compared to patients with PIC. Compared with TB, PIC favors the development of suppuration and the growth of periodontal pathogens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. "Who Is Helsinki" Sex Workers Advise Improving Communication for Good Participatory Practice in Clinical Trials

    ERIC Educational Resources Information Center

    Ditmore, Melissa Hope; Allman, Dan

    2011-01-01

    After premature closures in 2004 of biomedical human immunodeficiency virus (HIV) prevention trials involving sex workers in Africa and Asia, the Joint United Nations Programme on HIV/AIDS (UNAIDS) and Global Advocacy for HIV Prevention (AVAC) undertook consultations to establish better participatory guidelines for such trials in order to address…

  17. Blended Learning in MBA Education: A Cross-Cultural Experiment

    ERIC Educational Resources Information Center

    Magnier-Watanabe, Remy; Benton, Caroline; Herrig, Harald; Aba, Olivier

    2011-01-01

    e-Learning has entered the mainstream in higher education and many institutions are implementing technology-mediated learning at some level. This paper outlines the case of a course taught jointly in 2010 over three months by two graduate programmes in management at the University of Tsukuba in Japan and the Grenoble Ecole de Management in France…

  18. Critical Friendship as a Contribution to Master's-Level Work in an International Programme of Study

    ERIC Educational Resources Information Center

    van Swet, Jacqueline; Smit, Ben H. J.; Corvers, Louise; van Dijk, Ineke

    2009-01-01

    This article reports on an action research project in which the value of critical friendship for students doing research and writing their dissertations within an international master's course has been explored. This course is run jointly by Roehampton University (London, UK), Charles University (Prague, Czech Republic) together with Fontys OSO…

  19. Innovations in Equipping EYL Teachers for Future Challenges: UUM TEYL Perspective

    ERIC Educational Resources Information Center

    Karim, Hamida Bee Bi Abdul; Yusof, Fahainis Mohd.

    2012-01-01

    This paper seeks to highlight perceptions of students undergoing the Teaching of English to Young Learners (TEYL) programme jointly run by UUM and KPM since 2004. It focuses on their level of satisfaction from both academic amid non-academic aspects, particularly on the effectiveness of teaching methods employed by both local and international…

  20. Measuring the Success of Facilitated Engagement between Knowledge Producers and Users: A Validated Scale

    ERIC Educational Resources Information Center

    Dwan, Kathryn Madonna; McInnes, Peter; Mazumdar, Soumya

    2015-01-01

    Researchers are increasingly being asked to demonstrate the impact of their research on policy. Unfortunately, evidence on what works is scarce because it is rarely reported and evaluated. This paper describes a programme of facilitated engagement between knowledge producers and users on topics of joint research and policy interest, and validates…

  1. Building the Future Students' Blended Learning Experiences from Current Research Findings

    ERIC Educational Resources Information Center

    Jefferies, Amanda; Hyde, Ruth

    2010-01-01

    Between March 2007 and February 2009, the Joint Information Systems Committee (JISC) funded a Learners Journeys project at the University of Hertfordshire. This was part of their second phase of investment in research into the Learners' Experiences through their E-Learning Programme and was known as LXP2. STROLL (STudent Reflections On Lifelong…

  2. Continuing Vocational Training in the Space Industry: A Siberian Case Study

    ERIC Educational Resources Information Center

    Churlyaeva, Natalya; Kukushkin, Sergey

    2013-01-01

    The development of a continuing vocational training programme at the Information Satellite Systems Joint-Stock Company (ISS JSC) during the transition from the planned Soviet economy to what is now called the Russian market economy is briefly outlined. How the collapse of a planned economy led to the degradation of engineering higher education…

  3. Merging perspectives in the catchment sciences: the US-Japan Joint Seminar on catchment hydrology and forest biogeochemistry

    Treesearch

    Kevin J. McGuire; Stephen D. Sebestyen; Nobuhito Ohte; Emily M. Elliott; Takashi Gomi; Mark B. Green; Brian L. McGlynn; Naoko Tokuchi

    2014-01-01

    Japan has strong research programmes in the catchment sciences that overlap with interests in the US catchment science community, particularly in experimental and field-based research. Historically, however, there has been limited interaction between these two hydrologic science communities because of differences in language, culture, and research approaches. These...

  4. The Mobile Learning Network: Getting Serious about Games Technologies for Learning

    ERIC Educational Resources Information Center

    Petley, Rebecca; Parker, Guy; Attewell, Jill

    2011-01-01

    The Mobile Learning Network currently in its third year, is a unique collaborative initiative encouraging and enabling the introduction of mobile learning in English post-14 education. The programme, funded jointly by the Learning and Skills Council and participating colleges and schools and supported by LSN has involved nearly 40,000 learners and…

  5. Comparison of the Solubility of Conventional Luting Cements with that of the Polyacid Modified Composite Luting Cement and Resin-modified Glass lonomer Cement.

    PubMed

    Karkera, Reshma; Raj, A P Nirmal; Isaac, Lijo; Mustafa, Mohammed; Reddy, R Naveen; Thomas, Mathew

    2016-12-01

    This study was planned to find the solubility of the conventional luting cements in comparison with that of the polyacid-modified composite luting cement and recently introduced resin-modified glass ionomer cement (RMGIC) with exposure to water at early stages of mixing. An in vitro study of the solubility of the following five commercially available luting cements, viz., glass ionomer cement (GIC) (Fuji I, GC), zinc phosphate (Elite 100, GC), polyacid-modified resin cement (PMCR) (Principle, Dentsply), polycarboxylate cement (PC) (Poly - F, Dentsply), RMGIC (Vitremer, 3M), was conducted. For each of these groups of cements, three resin holders were prepared containing two circular cavities of 5 mm diameter and 2 mm depth. All the cements to be studied were mixed in 30 seconds and then placed in the prepared cavities in the resin cement holder for 30 seconds. From all of the observed luting cements, PMCR cement had shown the lowest mean loss of substance at all immersion times and RMGIC showed the highest mean loss of substanceat all immersion times in water from 2 to 8 minutes. The solubility of cements decreased by 38% for GIC, 33% for ZnPO 4 , 50% for PMCR, 29% for PC, and 17% for RMGIC. The PMCR cement (Principle-Dentsply) had shown lowest solubility to water at the given time intervals of immersion. This was followed by PC, zinc phosphate, and GIC to various time intervals of immersion.

  6. Development of high-performance blended cements

    NASA Astrophysics Data System (ADS)

    Wu, Zichao

    2000-10-01

    This thesis presents the development of high-performance blended cements from industrial by-products. To overcome the low-early strength of blended cements, several chemicals were studied as the activators for cement hydration. Sodium sulfate was discovered as the best activator. The blending proportions were optimized by Taguchi experimental design. The optimized blended cements containing up to 80% fly ash performed better than Type I cement in strength development and durability. Maintaining a constant cement content, concrete produced from the optimized blended cements had equal or higher strength and higher durability than that produced from Type I cement alone. The key for the activation mechanism was the reaction between added SO4 2- and Ca2+ dissolved from cement hydration products.

  7. Calcium phosphate compatible bone cement: Characterization, bonding properties and tissue response

    NASA Astrophysics Data System (ADS)

    Roemhildt, Maria Lynn

    A novel, inorganic, bone cement, containing calcium phosphate, developed for implant fixation was evaluated. Setting properties were determined over a range of temperatures. The flow of the cement was greatly increased by application of vibration. Changes in the cement during hydration and aging were evaluated. Compressive strength of the cement over time was studied under simulated physiological conditions from 1 hour to 1 year after setting. After 1 day, this cement had equivalent compressive strength to commercially used PMMA cement. The strength was found to increase over 1 month and high strength was maintained up to 1 year. The shear strength of the cement-metal interface was studied in vitro using a pull-out test. Prepared specimens were stored under physiological conditions and tested at 4 hours, 24 hours, and 60 days. Comparable interfacial shear strength values were found at 4 hours, 24 hours and 60 days for the experimental cement and were not significantly different from values obtained for PMMA cement. In vivo tissue response was evaluated after cement implantation in the femoral medullary canal in canines. Tissue response and bonding at the cement-bone interface were evaluated at 2, 6, and 12 weeks. Cortical bone was found in direct contact with the OC-cement and was healthy. The strength of the cement-bone interface, measured using a push-out test, was significantly higher for the experimental cement than for commercial PMMA bone cement.

  8. Peri-Implantitis Associated with Type of Cement: A Retrospective Analysis of Different Types of Cement and Their Clinical Correlation to the Peri-Implant Tissue.

    PubMed

    Korsch, Michael; Walther, Winfried

    2015-10-01

    The cementation of fixed implant-supported dental restorations involves the risk of leaving excess cement in the mouth which can promote biofilm formation in the peri-implant sulcus. As a result, an inflammation may develop. The aim of the present study was to investigate the clinical effect of two different luting cements on the peri-implant tissue. Within the scope of a retrospective clinical follow-up study, the prosthetic structures of 22 patients with 45 implants were revised. In all cases, a methacrylate cement (Premier Implant Cement [PIC], Premier® Dental Products Company, Plymouth Meeting, PA, USA) had been used for cementation. In 16 additional patients with 28 implants, the suprastructures were retained with a zinc oxide-eugenol cement (Temp Bond [TB], Kerr Sybron Dental Specialities, Glendora, CA, USA). These patients were evaluated in the course of routine treatment. In both populations, the retention time of the suprastructures was similar (TB 3.77 years, PIC 4.07 years). In the PIC cases, 62% of all implants had excess cement. In the TB cases, excess cement was not detectable on any of the implants. Bleeding on probing was significantly more frequent on implants cemented with PIC (100% with and 94% without excess cement) than on implants cemented with TB (46%). Pocket suppuration was observed on 89% of the PIC-cemented implants with excess cement (PIC without excess cement 24%), whereas implants with TB were not affected by it at all. The peri-implant bone loss was significantly greater in the PIC patients (with excess cement 1.37 mm, without excess cement 0.41 mm) than it was in the TB patients (0.07 mm). The frequency of undetected excess cement depends essentially on the type of cement used. Cements that tend to leave more undetected excess have a higher prevalence for peri-implant inflammation and cause a more severe peri-implant bone loss. © 2014 Wiley Periodicals, Inc.

  9. In vitro bond strength and fatigue stress test evaluation of different adhesive cements used for fixed space maintainer cementation

    PubMed Central

    Cantekin, Kenan; Delikan, Ebru; Cetin, Secil

    2014-01-01

    Objective: The purposes of this research were to (1) compare the shear-peel bond strength (SPBS) of a band of a fixed space maintainer (SM) cemented with five different adhesive cements; and (2) compare the survival time of bands of SM with each cement type after simulating mechanical fatigue stress. Materials and Methods: Seventy-five teeth were used to assess retentive strength and another 50 teeth were used to assess the fatigue survival time. SPBS was determined with a universal testing machine. Fatigue testing was conducted in a ball mill device. Results: The mean survival time of bands cemented with R & D series Nova Glass-LC (6.2 h), Transbond Plus (6.7 h), and R & D series Nova Resin (6.8 h) was significantly longer than for bands cemented with Ketac-Cem (5.4 h) and GC Equia (5.2 h) (P < 0.05). Conclusion: Although traditional glass ionomer cement (GIC) cement presented higher retentive strength than resin-based cements (resin, resin modified GIC, and compomer cement), resin based cements, especially dual cure resin cement (nova resin cement) and compomer (Transbond Plus), can be expected to have lower failure rates for band cementation than GIC (Ketac-Cem) in the light of the results of the ball mill test. PMID:25202209

  10. Influence of temporary cement contamination on the surface free energy and dentine bond strength of self-adhesive cements.

    PubMed

    Takimoto, Masayuki; Ishii, Ryo; Iino, Masayoshi; Shimizu, Yusuke; Tsujimoto, Akimasa; Takamizawa, Toshiki; Ando, Susumu; Miyazaki, Masashi

    2012-02-01

    The surface free energy and dentine bond strength of self-adhesive cements were examined after the removal of temporary cements. The labial dentine surfaces of bovine mandibular incisors were wet ground with #600-grit SiC paper. Acrylic resin blocks were luted to the prepared dentine surfaces using HY Bond Temporary Cement Hard (HY), IP Temp Cement (IP), Fuji TEMP (FT) or Freegenol Temporary Cement (TC), and stored for 1 week. After removal of the temporary cements with an ultrasonic tip, the contact angle values of five specimens per test group were determined for the three test liquids, and the surface-energy parameters of the dentine surfaces were calculated. The dentine bond strengths of the self-adhesive cements were measured after removal of the temporary cements in a shear mode at a crosshead speed of 1.0mm/min. The data were subjected to one-way analysis of variance (ANOVA) followed by Tukey's HSD test. For all surfaces, the value of the estimated surface tension component γ(S)(d) (dispersion) was relatively constant at 41.7-43.3 mJm(-2). After removal of the temporary cements, the value of the γ(S)(h) (hydrogen-bonding) component decreased, particularly with FT and TC. The dentine bond strength of the self-adhesive cements was significantly higher for those without temporary cement contamination (8.2-10.6 MPa) than for those with temporary cement contamination (4.3-7.1 MPa). The γ(S) values decreased due to the decrease of γ(S)(h) values for the temporary cement-contaminated dentine. Contamination with temporary cements led to lower dentine bond strength. The presence of temporary cement interferes with the bonding performance of self-adhesive cements to dentine. Care should be taken in the methods of removal of temporary cement when using self-adhesive cements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Sustainability and integration of radioecology-position paper.

    PubMed

    Muikku, M; Beresford, N A; Garnier-Laplace, J; Real, A; Sirkka, L; Thorne, M; Vandenhove, H; Willrodt, C

    2018-03-01

    This position paper gives an overview of how the COMET project (COordination and iMplementation of a pan-European instrumenT for radioecology, a combined Collaborative Project and Coordination and Support Action under the EC/Euratom 7th Framework Programme) contributed to the integration and sustainability of radioecology in Europe via its support to and interaction with the European Radioecology ALLIANCE. COMET built upon the foundations laid by the FP7 project STAR (Strategic Network for Integrating Radioecology) Network of Excellence in radioecology. In close association with the ALLIANCE, and based on the Strategic Research Agenda (SRA), COMET developed innovative mechanisms for joint programming and implementation of radioecological research. To facilitate and foster future integration under a common federating structure, research activities developed within COMET were targeted at radioecological research needs identified in the SRA. Furthermore, COMET maintained and developed strong mechanisms for knowledge exchange, dissemination and training to enhance and maintain European capacity, competence and skills in radioecology. In the short term the work to promote radioecology will continue under the H2020 project EJP-CONCERT (European Joint Programme for the Integration of Radiation Protection Research). The EJP-CONCERT project (2015-2020) aims to develop a sustainable structure for promoting and administering joint programming and open research calls in the field of radiation protection research for Europe. In the longer term, radioecological research will be facilitated by the ALLIANCE. External funding is, however, required in order to be able to answer emerging research needs.

  12. Increasing hip and knee flexion during a drop-jump task reduces tibiofemoral shear and compressive forces: implications for ACL injury prevention training.

    PubMed

    Tsai, Liang-Ching; Ko, Yi-An; Hammond, Kyle E; Xerogeanes, John W; Warren, Gordon L; Powers, Christopher M

    2017-12-01

    Although most ACL injury prevention programmes encourage greater hip and knee flexion during landing, it remains unknown how this technique influences tibiofemoral joint forces. We examined whether a landing strategy utilising greater hip and knee flexion decreases tibiofemoral anterior shear and compression. Twelve healthy women (25.9 ± 3.5 years) performed a drop-jump task before and after a training session (10-15 min) that emphasised greater hip and knee flexion. Peak tibiofemoral anterior shear and compressive forces were calculated using an electromyography (EMG)-driven knee model that incorporated joint kinematics, EMG and participant-specific muscle volumes and patella tendon orientation measured using magnetic resonance imaging (MRI). Participants demonstrated a decrease in peak anterior tibial shear forces (11.1 ± 3.3 vs. 9.6 ± 2.7 N · kg -1 ; P = 0.008) and peak tibiofemoral compressive forces (68.4 ± 7.6 vs. 62.0 ± 5.5 N · kg -1 ; P = 0.015) post-training. The decreased peak anterior tibial shear was accompanied by a decrease in the quadriceps anterior shear force, while the decreased peak compressive force was accompanied by decreased ground reaction force and hamstring forces. Our data provide justification for injury prevention programmes that encourage greater hip and knee flexion during landing to reduce tibiofemoral joint loading.

  13. Public health nutrition capacity: assuring the quality of workforce preparation for scaling up nutrition programmes.

    PubMed

    Shrimpton, Roger; du Plessis, Lisanne M; Delisle, Hélène; Blaney, Sonia; Atwood, Stephen J; Sanders, David; Margetts, Barrie; Hughes, Roger

    2016-08-01

    To describe why and how capacity-building systems for scaling up nutrition programmes should be constructed in low- and middle-income countries (LMIC). Position paper with task force recommendations based on literature review and joint experience of global nutrition programmes, public health nutrition (PHN) workforce size, organization, and pre-service and in-service training. The review is global but the recommendations are made for LMIC scaling up multisectoral nutrition programmes. The multitude of PHN workers, be they in the health, agriculture, education, social welfare, or water and sanitation sector, as well as the community workers who ensure outreach and coverage of nutrition-specific and -sensitive interventions. Overnutrition and undernutrition problems affect at least half of the global population, especially those in LMIC. Programme guidance exists for undernutrition and overnutrition, and priority for scaling up multisectoral programmes for tackling undernutrition in LMIC is growing. Guidance on how to organize and scale up such programmes is scarce however, and estimates of existing PHN workforce numbers - although poor - suggest they are also inadequate. Pre-service nutrition training for a PHN workforce is mostly clinical and/or food science oriented and in-service nutrition training is largely restricted to infant and young child nutrition. Unless increased priority and funding is given to building capacity for scaling up nutrition programmes in LMIC, maternal and child undernutrition rates are likely to remain high and nutrition-related non-communicable diseases to escalate. A hybrid distance learning model for PHN workforce managers' in-service training is urgently needed in LMIC.

  14. School food, politics and child health.

    PubMed

    Bundy, Donald A P; Drake, Lesley J; Burbano, Carmen

    2013-06-01

    An analysis undertaken jointly in 2009 by the UN World Food Programme, The Partnership for Child Development and the World Bank was published as Rethinking School Feeding to provide guidance on how to develop and implement effective school feeding programmes as a productive safety net and as part of the efforts to achieve Education for All. The present paper reflects on how understanding of school feeding has changed since that analysis. Data on school feeding programme outcomes were collected through a literature review. Regression models were used to analyse relationships between school feeding costs (from data that were collected), the per capita costs of primary education and Gross Domestic Product per capita. Data on the transition to national ownership, supply chains and country examples were collected through country case studies. School feeding programmes increase school attendance, cognition and educational achievement, as well as provide a transfer of resources to households with possible benefits to local agricultural production and local market development. Low-income countries exhibit large variations in school feeding costs, with concomitant opportunities for cost containment. Countries are increasingly looking to transition from externally supported projects to national programmes. School feeding is now clearly evident as a major social programme in most countries with a global turnover in excess of $US 100 billion. This argues for a continuing focus on the evidence base with a view to helping countries ensure that their programmes are as cost-effective as possible. Clear policy advice has never been more important.

  15. Micro-mechanical damage of trabecular bone-cement interface under selected loading conditions: a finite element study.

    PubMed

    Zhang, Qing-Hang; Tozzi, Gianluca; Tong, Jie

    2014-01-01

    In this study, two micro finite element models of trabecular bone-cement interface developed from high resolution computed tomography (CT) images were loaded under compression and validated using the in situ experimental data. The models were then used under tension and shear to examine the load transfer between the bone and cement and the micro damage development at the bone-cement interface. In addition, one models was further modified to investigate the effect of cement penetration on the bone-cement interfacial behaviour. The simulated results show that the load transfer at the bone-cement interface occurred mainly in the bone cement partially interdigitated region, while the fully interdigitated region seemed to contribute little to the mechanical response. Consequently, cement penetration beyond a certain value would seem to be ineffective in improving the mechanical strength of trabecular bone-cement interface. Under tension and shear loading conditions, more cement failures were found in denser bones, while the cement damage is generally low under compression.

  16. Traction test of temporary dental cements

    PubMed Central

    Millan-Martínez, Diego; Fons-Font, Antonio; Agustín-Panadero, Rubén; Fernández-Estevan, Lucía

    2017-01-01

    Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and Methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear (TBC) and Telio CS link (TE). Each sample underwent traction testing, both with thermocycling (190 cycles at 5-55º) and without thermocycling. Results TE and TBC obtained the highest traction resistance values. Thermocycling reduced the resistance of all cements except TBC. Conclusions The dual-cure esthetic cements tested provided optimum outcomes for bonding provisional restorations. Key words:Temporary dental cements, cements resistance. PMID:28469824

  17. Creep and fatigue behavior of a novel 2-component paste-like formulation of acrylic bone cements.

    PubMed

    Köster, Ulrike; Jaeger, Raimund; Bardts, Mareike; Wahnes, Christian; Büchner, Hubert; Kühn, Klaus-Dieter; Vogt, Sebastian

    2013-06-01

    The fatigue and creep performance of two novel acrylic bone cement formulations (one bone cement without antibiotics, one with antibiotics) was compared to the performance of clinically used bone cements (Osteopal V, Palacos R, Simplex P, SmartSet GHV, Palacos R+G and CMW1 with Gentamicin). The preparation of the novel bone cement formulations involves the mixing of two paste-like substances in a static mixer integrated into the cartridge which is used to apply the bone cement. The fatigue performance of the two novel bone cement formulations is comparable to the performance of the reference bone cements. The creep compliance of the bone cements is significantly influenced by the effects of physical ageing. The model parameters of Struik's creep law are used to compare the creep behavior of different bone cements. The novel 2-component paste-like bone cement formulations are in the group of bone cements which exhibit a higher creep resistance.

  18. In-situ Mechanical Manipulation of Wellbore Cements as a Solution to Leaky Wells

    NASA Astrophysics Data System (ADS)

    Kupresan, D.; Radonjic, M.; Heathman, J.

    2013-12-01

    Wellbore cement provides casing support, zonal isolation, and casing protection from corrosive fluids, which are essential for wellbore integrity. Cements can undergo one or more forms of failure such as debonding at cement/formation and cement/casing interface, fracturing and defects within cement matrix. Failures and defects within cement will ultimately lead to fluids migration, resulting in inter-zonal fluid migration and premature well abandonment. There are over 27,000 abandoned oil and gas wells only in The Gulf of Mexico (some of them dating from the late 1940s) with no gas leakage monitoring. Cement degradation linked with carbon sequestration can potentially lead to contamination of fresh water aquifers with CO2. Gas leaks can particularly be observed in deviated wells used for hydraulic fracking (60% leakage rate as they age) as high pressure fracturing increases the potential for migration pathways. Experimental method utilized in this study enables formation of impermeable seals at interfaces present in a wellbore by mechanically manipulating wellbore cement. Preliminary measurements obtained in bench scale experiments demonstrate that an impermeable cement/formation and cement/casing interface can be obtained. In post-modified cement, nitrogen gas flow-through experiments showed complete zonal isolation and no permeability in samples with pre-engineered microannulus. Material characterization experiments of modified cement revealed altered microstructural properties of cement as well as changes in mineralogical composition. Calcium-silicate-hydrate (CSH), the dominant mineral in hydrated cement which provides low permeability of cement, was modified as a result of cement pore water displacement, resulting in more dense structures. Calcium hydroxide (CH), which is associated with low resistance of cement to acidic fluids and therefore detrimental in most wellbore cements, was almost completely displaced and/or integrated in CSH as a result of mechanical manipulation (shear stress). The main advantage of this methodology is that mechanical manipulation of cement can induce healing of existing fractures, channels and microannulus seal in a wellbore without introducing new materials (e.g. cement squeeze jobs). Furthermore, this methodology is less sensitive to the influence of downhole conditions such as pressure, temperature and formation fluids, since it uses cement pore water as a medium to alter cement sheath. Based on lab experiments observation, it is possible to perceive that once tested at the industrial scale and if successful, the implementation of this method in the field can potentially mitigate leaky wells in CO2 sequestration projects, wellbores completed for hydraulic-fracturing and other conventional oil and gas producing wells. Key words: Wellbore cement integrity; Leaky wells; Cement microstructures; Casing expansion effect on cement mineralogy alterations.

  19. Increased Antibiotic Release from a Bone Cement Containing Bacterial Cellulose

    PubMed Central

    Nakai, Takahisa; Enomoto, Koichi; Uchio, Yuji; Yoshino, Katsumi

    2010-01-01

    Background Major disadvantages of antibiotic bone cements include limited drug release and reduced strength resulting from the addition of high doses of antibiotics. Bacterial cellulose, a three-dimensional hydrophilic mesh, may retain antibiotics and release them gradually. We hypothesized that the addition of cellulose to antibiotic bone cement would improve mechanical strength and antibiotic release. Questions/purposes We therefore examined the mechanical strength and antibiotic release of cellulose antibiotic cement. Methods A high dose of antibiotics (5 g per 40 g cement powder) was incorporated into bacterial cellulose and then mixed with bone cement. We compared the compression strength, fracture toughness, fatigue life, and elution kinetics of this formulation with those of plain cement and a traditional antibiotic cement. Results The average values for compression strength, fracture toughness, and fatigue life of the cellulose antibiotic cement were 97%, 97%, and 78% of the values obtained for plain cement, respectively. The corresponding values for the traditional antibiotic cement were 79%, 82%, and 17%, respectively. The cumulative elution over 35 days was 129% greater from the cellulose antibiotic cement than from the traditional antibiotic cement. Conclusions With a high dose of antibiotics, incorporating cellulose into the bone cement prevented compression and fracture fragility, improved fatigue life, and increased antibiotic elution. Clinical Relevance Antibiotic cements containing cellulose may have applications in clinical situations that require high levels of antibiotic release and preservation of the mechanical properties of the cement. PMID:20945120

  20. Investigation of Possible Wellbore Cement Failures During Hydraulic Fracturing Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Jihoon; Moridis, George

    2014-11-01

    We model and assess the possibility of shear failure, using the Mohr-Coulomb model ? along the vertical well by employing a rigorous coupled flow-geomechanic analysis. To this end, we vary the values of cohesion between the well casing and the surrounding cement to representing different quality levels of the cementing operation (low cohesion corresponds to low-quality cement and/or incomplete cementing). The simulation results show that there is very little fracturing when the cement is of high quality.. Conversely, incomplete cementing and/or weak cement can causes significant shear failure and the evolution of long fractures/cracks along the vertical well. Specifically, lowmore » cohesion between the well and cemented areas can cause significant shear failure along the well, but the same cohesion as the cemented zone does not cause shear failure. When the hydraulic fracturing pressure is high, low cohesion of the cement can causes fast propagation of shear failure and of the resulting fracture/crack, but a high-quality cement with no weak zones exhibits limited shear failure that is concentrated near the bottom of the vertical part of the well. Thus, high-quality cement and complete cementing along the vertical well appears to be the strongest protection against shear failure of the wellbore cement and, consequently, against contamination hazards to drinking water aquifers during hydraulic fracturing operations.« less

  1. Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players

    PubMed Central

    Fu, Lin

    2017-01-01

    The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p < 0.05, r = 0.89) and inversion joint moment (p < 0.05, r = 0.54) in the frontal plane as well as greater internal joint rotation moment (p < 0.05, r = 0.28) in the horizontal plane. In contrast, professional badminton players presented a greater knee joint moment in the sagittal (p < 0.05, r = 0.59) and frontal (p < 0.05, r = 0.37) planes, which may be associated with increased knee ligamentous injury risk. To avoid injury, the players need to forcefully extend the knee with internal rotation, strengthen the muscles around the ankle ligament, and maximise joint coordination during training. The injuries recorded and the forces responsible for the injuries seem to have developed during training activity. Training programmes and injury prevention strategies for badminton players should account for these findings to reduce potential injury to the ankle and knee. PMID:28694684

  2. Ground Support Strategies at the Turquoise Ridge Joint Venture, Nevada

    NASA Astrophysics Data System (ADS)

    Sandbak, L. A.; Rai, A. R.

    2013-05-01

    Weak rock masses of high grade Carlin-trend gold mineralization are encountered in the Turquoise Ridge Joint Venture underground mine. The sediments consist of very weak and altered limestone, mudstone, and carbon-rich clays. The rock mass ratings are described as very poor to poor (Bieniawski in Proceedings of the symposium on exploration for rock engineering, Johannesburg, South Africa, pp. 97-106, 1976). The undercut and fill or boxes stoping mining methods are used because of the low dipping ore body geometry, complex geology, and weak rock mass. Design criteria are chosen to keep openings in weak rock as small as possible to prevent unraveling and to minimize supplementary support. Typical ground support for drifting includes the use of bolts, mesh, spiling, and shotcrete. Quality control of cemented rock fill (CRF) through sampling and aggregate sieve testing is necessary to insure high support strength. Specific support may include shotcrete arches with steel ring sets and CRF "arches" as a replacement of weak rock masses around long-term mine openings. Movement monitoring is utilized in problem areas and is needed to quantify and validate computer modeling.

  3. Imaging Wellbore Cement Degradation by Carbon Dioxide under Geologic Sequestration Conditions Using X-ray Computed Microtomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jung, Hun Bok; Jansik, Danielle; Um, Wooyong

    2013-01-02

    ABSTRACT: X-ray microtomography (XMT), a nondestructive three-dimensional imaging technique, was applied to demonstrate its capability to visualize the mineralogical alteration and microstructure changes in hydrated Portland cement exposed to carbon dioxide under geologic sequestration conditions. Steel coupons and basalt fragments were added to the cement paste in order to simulate cement-steel and cement-rock interfaces. XMT image analysis showed the changes of material density and porosity in the degradation front (density: 1.98 g/cm3, porosity: 40%) and the carbonated zone (density: 2.27 g/cm3, porosity: 23%) after reaction with CO2- saturated water for 5 months compared to unaltered cement (density: 2.15 g/cm3, porosity:more » 30%). Three-dimensional XMT imaging was capable of displaying spatially heterogeneous alteration in cement pores, calcium carbonate precipitation in cement cracks, and preferential cement alteration along the cement-steel and cement-rock interfaces. This result also indicates that the interface between cement and host rock or steel casing is likely more vulnerable to a CO2 attack than the cement matrix in a wellbore environment. It is shown here that XMT imaging can potentially provide a new insight into the physical and chemical degradation of wellbore cement by CO2 leakage.« less

  4. The Influence of Cement Morphology Parameters on the Strength of the Cement-Bone Interface in Tibial Tray Fixation.

    PubMed

    Nagel, Katrin; Bishop, Nicholas E; Schlegel, Ulf J; Püschel, Klaus; Morlock, Michael M

    2017-02-01

    The strength of the cement-bone interface in tibial component fixation depends on the morphology of the cement mantle. The purpose of this study was to identify thresholds of cement morphology parameters to maximize fixation strength using a minimum amount of cement. Twenty-three cadaveric tibiae were analyzed that had been implanted with tibial trays in previous studies and for which the pull-out strength of the tray had been measured. Specimens were separated into a group failing at the cement-bone interface (INTERFACE) and one failing in the bulk bone (BULK). Maximum pull-out strength corresponds to the ultimate strength of the bulk bone if the cement-bone interface is sufficiently strong. 3D models of the cement mantle in situ were reconstructed from computed tomography scans. The influences of bone mineral density and 6 cement morphology parameters (reflecting cement penetration, bone-cement interface, cement volume) on pull-out strength of the BULK group were determined using multiple regression analysis. The threshold of each parameter for classification of the specimens into either group was determined using receiver operating characteristic analysis. Cement penetration exceeding a mean of 1.1 mm or with a maximum of 5.6 mm exclusively categorized all BULK bone failure specimens. Failure strength of BULK failure specimens increased with bone mineral density (R 2  = 0.67, P < .001) but was independent of the cement morphology parameters. To maximize fixation strength, a mean cement penetration depth of at least 1.1 mm should be achieved during tibial tray cementing. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Comparison of microleakage of three acid-base luting cements versus one resin-bonded cement for Class V direct composite inlays.

    PubMed

    Piemjai, Morakot; Miyasaka, Kumiko; Iwasaki, Yasuhiko; Nakabayashi, Nobuo

    2002-12-01

    Demineralized dentin beneath set cement may adversely affect microleakage under fixed restorations. Microleakage of direct composite inlays cemented with acid-base cements and a methyl methacrylate resin cement were evaluated to determine their effect on the integrity of the underlying hybridized dentin. Sixty Class V box preparations (3 mm x 3 mm x 1.5 mm) were precisely prepared in previously frozen bovine teeth with one margin in enamel and another margin in dentin. Direct composite inlays (EPIC-TMPT) for each preparation were divided into 4 groups of 15 specimens each and cemented with 3 acid-base cements (control group): Elite, Ketac-Cem, Hy-Bond Carbo-Cem, and 1 adhesive resin cement: C&B Metabond. All specimens were stored in distilled water for 24 hours at 37 degrees C before immersion in 0.5% basic fuchsin for 24 hours. The dye penetration was measured on the sectioned specimens at the tooth-cement interface of enamel and cementum margins and recorded with graded criteria under light microscopy (Olympus Vanox-T) at original magnification x 50, 100, and 200. A Kruskal-Wallis and the Mann-Whitney test at P<.05 were used to analyze leakage score. All cementum margins of the 3 acid-base cements tested demonstrated significantly higher leakage scores than cementum margins for inlays cemented with the resin cement tested(P<.01). No leakage along the tooth-cement interface was found for inlays retained with the adhesive resin cement. Within the limitations of this study, the 3 acid-base cements tested exhibited greater microleakage at the cementum margins than did the adhesive resin cement that was tested.

  6. Retention of cast crown copings cemented to implant abutments.

    PubMed

    Dudley, J E; Richards, L C; Abbott, J R

    2008-12-01

    The cementation of crowns to dental implant abutments is an accepted form of crown retention that requires consideration of the properties of available cements within the applied clinical context. Dental luting agents are exposed to a number of stressors that may reduce crown retention in vivo, not the least of which is occlusal loading. This study investigated the influence of compressive cyclic loading on the physical retention of cast crown copings cemented to implant abutments. Cast crown copings were cemented to Straumann synOcta titanium implant abutments with three different readily used and available cements. Specimens were placed in a humidifier, thermocycled and subjected to one of four quantities of compressive cyclic loading. The uniaxial tensile force required to remove the cast crown copings was then recorded. The mean retention values for crown copings cemented with Panavia-F cement were statistically significantly greater than both KetacCem and TempBond non-eugenol cements at each compressive cyclic loading quantity. KetacCem and TempBond non-eugenol cements produced relatively low mean retention values that were not statistically significantly different at each quantity of compressive cyclic loading. Compressive cyclic loading had a statistically significant effect on Panavia-F specimens alone, but increased loading quantities produced no further statistically significant difference in mean retention. Within the limitations of the current in vitro conditions employed in this study, the retention of cast crown copings cemented to Straumann synOcta implant abutments with a resin, glass ionomer and temporary cement was significantly affected by cement type but not compressive cyclic loading. Resin cement is the cement of choice for the definitive non-retrievable cementation of cast crown copings to Straumann synOcta implant abutments out of the three cements tested.

  7. Hydration products and thermokinetic properties of cement-bentonite and cement-chalk mortars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klyusov, A.A.

    1988-08-20

    Bentonite and chalk are the most popular auxiliary additives to portland cement for borehole cementation. The authors studied by physicochemical analysis methods (x-ray phase, derivatographic, and scanning and electron microscopy in combination with microdiffraction) the newly formed solid-phase composition of cement-bentonite and cement-chalk mortars (binder-additive ratio 9:1) prepared from portland cement for cold boreholes and 8% calcium chloride solution at a water-mixing ratio of 0.9. The mechanism of the influence of Ca-bentonite and chalk additives on the portland cement hydration rate was ascertained from the heat evolution rate curves. It was found that the phase compositions of the hydration productsmore » are represented in the studied systems by newly formed substances typical for portland cement. It has been noted that Ca-bentonite interacts with the calcium hydroxide of hydrated cement with the formation of hexagonal and cubic calcium hydroaluminates. Unlike Ca-bentonite, chalk does not react with portland cement at normal and reduced temperatures, does not block hydrated cement particles, which, in turn, ensures all other conditions remaining equal, a higher initial rate of hydration of cement-chalk mortar.« less

  8. Influence of Cements Containing Calcareous Fly Ash as a Main Component Properties of Fresh Cement Mixtures

    NASA Astrophysics Data System (ADS)

    Gołaszewski, Jacek; Kostrzanowska-Siedlarz, Aleksandra; Ponikiewski, Tomasz; Miera, Patrycja

    2017-10-01

    The main goal of presented research was to examine usability of cements containing calcareous fly ash (W) from technological point of view. In the paper the results of tests concerning the influence of CEM II and CEM IV cements containing fly ash (W) on rheological properties, air content, setting times and plastic shrinkage of mortars are presented and discussed. Moreover, compatibility of plasticizers with cements containing fly ash (W) was also studied. Additionally, setting time and hydration heat of cements containing calcareous fly ash (W) were determined. In a broader aspect, the research contributes to promulgation of the possibility of using calcareous fly ash (W) in cement and concrete technology, what greatly benefits the environment protection (utilization of waste fly ash). Calcareous fly ash can be used successfully as the main component of cement. Cements produced by blending with processed fly ash or cements produced by interginding are characterized by acceptable technological properties. In respect to CEM I cements, cements containing calcareous fly ash worsen workability, decrease air content, delay setting time of mixtures. Cements with calcareous fly ash show good compatibility with plasticizers.

  9. 76 FR 76760 - Gray Portland Cement and Cement Clinker From Japan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... and Cement Clinker From Japan Determination On the basis of the record \\1\\ developed in the subject... duty order on gray Portland cement and cement clinker from Japan would be likely to lead to... and Cement Clinker from Japan: Investigation No. 731- TA-461 (Third Review). By order of the...

  10. The extent of slits at the interfaces between luting cements and enamel, dentin and alloy.

    PubMed

    Oilo, G

    1978-01-01

    Four different cements were used to assess the presence of slits at the cement/tooth or the cement/alloy interfaces using a tooth-crown model. The model consisted of ground sections of teeth and plane plates of silver/palladium alloy. The plates were fixed with bolts between two brass plates and with three different dimensions of the cement film between tooth and alloy, i.e. 50 micrometer, 100 micrometer and 200 micrometer. The tooth-alloy specimens were sectioned and the adaption of cements was studied with an indirect technique (replica) in a scanning electron microscope. The extent of slits was expressed as the length of all slits relative to the total length of the interface in each specimen. The results showed that the zinc phosphate cement and polycarboxylate cement exhibited a slight to moderate tendency to formation of slits at the interfaces. The EBA cement had a small extent of slits adjacent to thin cement films, but more slits were observed with increasing film thickness. The composite resin cement had a marked tendency to slit formation independent of the cement film thickness.

  11. A telerobotic digital controller system

    NASA Technical Reports Server (NTRS)

    Brown, Richard J.

    1992-01-01

    This system is a network of joint mounted dual axes digital servo-controllers (DDSC), providing control of various joints and end effectors of different robotic systems. This report provides description of and user required information for the Digital Controller System Network (DSCN) and, in particular, the DDSC, Model DDSC-2, developed to perform the controller functions. The DDSC can control 3 phase brushless or brush type DC motors, requiring up to 8 amps. Only four wires, two for power and 2 for serial communication, are required, except for local sensor and motor connections. This highly capable, very flexible, programmable servo-controller, contained on a single, compact printed circuit board measuring only 4.5 x 5.1 inches, is applicable to control systems of all types from sub-arc second precision pointing to control of robotic joints and end effectors. This document concentrates on the robotic applications for the DDSC.

  12. The design and development of a triaxial wear-testing joint simulator.

    PubMed

    Green, A S; O'Connell, M K; Lyons, A S; James, S P

    1999-01-01

    Most of the existing wear testers created to wear test total hip replacements, specifically the acetabular component, are designed to exert only an axial force and provide rotation in a close approximation of the actual femoral movement. The Rocky Mountain Joint Simulator was designed to exert three orthogonal forces and provide rotations about the X-, Y- and Z-axes to more closely simulate the physiological forces and motions found in the human gait cycle. The RMJS was also designed with adaptability for other joints, such as knees or canine hips, through the use of hydraulics and a computer-programmable control system. Such adaptability and functionality allows the researcher to more closely model a gait cycle, thereby obtaining wear patterns that resemble those found in retrieved implants more closely than existing simulators. Research is ongoing into the tuning and evaluation of the machine and preliminary acetabular component wear test results will be presented at the conference.

  13. Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

    PubMed Central

    Sibanda, Nokuthaba; Copley, Lynn P; Lewsey, Jim D; Borroff, Mick; Gregg, Paul; MacGregor, Alex J; Pickford, Martin; Porter, Martyn; Tucker, Keith; van der Meulen, Jan H

    2008-01-01

    Background Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according to prosthesis type. Methods and Findings We linked records of the National Joint Registry for England and Wales and the Hospital Episode Statistics for patients with a primary hip or knee replacement in the National Health Service in England between April 2003 and September 2006. Hospital Episode Statistics records of succeeding admissions were used to identify revisions for any reason. 76,576 patients with a primary hip replacement and 80,697 with a primary knee replacement were included (51% of all primary hip and knee replacements done in the English National Health Service). In hip patients, 3-y revision rates were 0.9% (95% confidence interval [CI] 0.8%–1.1%) with cemented, 2.0% (1.7%–2.3%) with cementless, 1.5% (1.1%–2.0% CI) with “hybrid” prostheses, and 2.6% (2.1%–3.1%) with hip resurfacing (p < 0.0001). Revision rates after hip resurfacing were increased especially in women. In knee patients, 3-y revision rates were 1.4% (1.2%–1.5% CI) with cemented, 1.5% (1.1%–2.1% CI) with cementless, and 2.8% (1.8%–4.5% CI) with unicondylar prostheses (p < 0.0001). Revision rates after knee replacement strongly decreased with age. Interpretation Overall, about one in 75 patients needed a revision of their prosthesis within 3 y. On the basis of our data, consideration should be given to using hip resurfacing only in male patients and unicondylar knee replacement only in elderly patients. PMID:18767900

  14. Over 25 years survival after Charnley's total hip arthroplasty.

    PubMed

    Caton, Jacques; Prudhon, Jean Louis

    2011-02-01

    Since 1962, the low friction arthroplasty (LFA) developed by Sir John Charnley has spread widely throughout the world. Many series have reported long-term results. Polyethylene (PE) wear is well known. The average wear ratio is about 0.1 mm a year. Many factors may influence that wear process. The authors describe two different series of patients operated upon with Charnley's total hip arthroplasty (THA) using the original cemented stem and a non modular 22.2-mm head, with a cemented full polyethylene acetabular socket. Outcomes confirm excellent patient function after 25 years. They emphasise the fact that PE is the weak point of total hip arthroplasty. Function may be excellent even though PE wear is significant. In several cases, no wear at the maximum follow-up was detectable. This study confirms different publications relating long-term follow-up with LFA. During a Charnley meeting in Lyon, we published a survival curve of 85% after 25 years. Berry et al. published a 86.5% survival curve (J Bone Joint Surg Am 84:171-177, 2002). In 1995, Luc and Marcel Kerboul published a 77% survival rate after 20 years in young patients under 40 years old at the time of the surgery. In 2009, Callaghan et al. published a series of 35 years follow-up with a ratio of 78% survivorship (J Bone Joint Surg Br 91:2617-2621). Could the long-term results be improved? Through recent decades, many solutions have been introduced to improve the survivorship of THA including bearing surfaces such as alumina-on-alumina and metal-on-metal. Different problems have occurred with these solutions. LFA might be improved by working on the nature and the quality of the head. Improvements might also be obtained by working on the quality and the hardness of the acetabular socket.

  15. In vitro tensile strength of luting cements on metallic substrate.

    PubMed

    Orsi, Iara A; Varoli, Fernando K; Pieroni, Carlos H P; Ferreira, Marly C C G; Borie, Eduardo

    2014-01-01

    The aim of this study was to determine the tensile strength of crowns cemented on metallic substrate with four different types of luting agents. Twenty human maxillary molars with similar diameters were selected and prepared to receive metallic core castings (Cu-Al). After cementation and preparation the cores were measured and the area of crown's portion was calculated. The teeth were divided into four groups based on the luting agent used to cement the crowns: zinc phosphate cement; glass ionomer cement; resin cement Rely X; and resin cement Panavia F. The teeth with the crowns cemented were subjected to thermocycling and later to the tensile strength test using universal testing machine with a load cell of 200 kgf and a crosshead speed of 0.5 mm/min. The load required to dislodge the crowns was recorded and converted to MPa/mm(2). Data were subjected to Kruskal-Wallis analysis with a significance level of 1%. Panavia F showed significantly higher retention in core casts (3.067 MPa/mm(2)), when compared with the other cements. Rely X showed a mean retention value of 1.877 MPa/mm(2) and the zinc phosphate cement with 1.155 MPa/mm(2). Glass ionomer cement (0.884 MPa/mm(2)) exhibited the lowest tensile strength value. Crowns cemented with Panavia F on cast metallic posts and cores presented higher tensile strength. The glass ionomer cement showed the lowest tensile strength among all the cements studied.

  16. Impact of Casing Expansion on the Mechanical and Petro-Physical Properties of Wellbore Cements

    NASA Astrophysics Data System (ADS)

    Oyibo, A. E.

    2014-12-01

    The main objective of this research is to investigate the applicability of expandable casing technology as a remediation technique for leaky wells resulting in gas migration problems. Micro annulus is usually created at the cement-formation/cement-casing interface or within the cement matrix either due to poor primary cementing or as a result of activities such as temperature and pressure variation or fracturing operations. Recent reports on gas migration in hydraulically fractured wellbores, has raised concerns on the contamination of fresh water aquifers resulting from fluid migration though this flow path. A unique bench-scale physical model which utilizes expandable tubulars in the remediation of micro annular gas flow has been used to simulate expansion of a previously-cemented casing under field-like conditions. Three different designs of cement slurry: regular 16.4 lb. /gal, 16.4 lb. /gal base slurry foamed to 13 lb. /gal and 16.4 lb. /gal cement slurry with 10% salt concentration. Gas flow path (microannulus) was artificially created at the pipe-cement interface by rotating the inner pipe in a pipe inside pipe assembly with cement in the annulus within the first few hours of hydration to create debonding at the cement-casing interface. Nitrogen gas flow-through experiments were performed before and after the expansion to confirm the sealing of the microannulus. The results obtained confirmed the effectiveness of this technique in the complete closure of gas leakage path, providing seal-tight cement-formation interface free of microannulus. The manipulation of the cement sheath during the casing expansion resulted in improved porosity, permeability and the strength of the cement sheath. SEM micrographs revealed decrease in pore size and fracturing of unhydrated cement grains within the cement matrix. This technology has great potential to become one of the leading cement remediation techniques for leaks behind the casing if implemented. Keywords: Wellbore Integrity, Casing Expansion, Well Gas Leaks, CSH, Pore Collapse, Cement Pore Water.

  17. Managing the Process of International Collaboration in Online Course Development: A Case-Example Involving Higher Education Institutions in Ireland, Switzerland, Austria, and the United Kingdom

    ERIC Educational Resources Information Center

    Ryan, Cathal; Bergin, Michael; Titze, Sylvia; Ruf, Wolfgang; Kunz, Stefan; Mazza, Riccardo; Chalder, Trudie; Windgassen, Sula; Miner, Dianne Cooney; Wells, John S. G.

    2017-01-01

    There has been significant growth recently in online learning and joint programmes of education involving collaborative partnerships between and among higher education institutions in different jurisdictions. Utilising an interdisciplinary team model (Care and Scanlan 2001), we describe in this article the process of collaboration among four…

  18. Co-Production of Quality in the Applied Education Research Scheme

    ERIC Educational Resources Information Center

    Ozga, Jenny

    2007-01-01

    This contribution looks at the ways in which research quality is defined and addressed in the Applied Education Research Scheme (AERS), particularly within the network on Schools and Social Capital, which is one of the four areas of work within the overall AERS scheme. AERS is a five-year programme, funded jointly by the Scottish Executive and the…

  19. Scientists Grow Therapeutic Protein in Engineered Soya Bean Seeds to Prevent AIDS | Poster

    Cancer.gov

    Genetically modified soya beans provide a scalable, low-cost method of producing microbicides that prevent AIDS, a technique sustainable for resource-poor countries where AIDS is spreading rapidly. According to the Joint United Nations Programme on HIV/AIDS, more than 36 million people worldwide are living with HIV. While the number of AIDS-related deaths are decreasing,

  20. Remembering History: The Work of the Information Services Sub-Committee of the Joint Information Systems Committee in the UK

    ERIC Educational Resources Information Center

    Law, Derek

    2006-01-01

    Purpose: The paper seeks to record the work of the committee and its interaction with the much better known Electronic Libraries (eLib) Programme. It also examines the principles that underlay the development of content acquisition and supporting infrastructure in UK university libraries in the 1990s. Design/methodology/approach: A historical…

Top